Loading...
HomeMy WebLinkAboutSDP202100085 Review Comments Preliminary Site Plan 2021-12-22 (2)From: Dvon Veoa To: Ben Hol Cc: devreview(olrivanna.ora; Richard Nelson Subject: North Point Section 1E Comments Date: Thursday, December 2, 2021 3:24:33 PM Attachments: Imaae001. ona CAUTION: This message originated outside the County of Albemarle email system. DO NOT CLICK on links or open attachments unless you are sure the content is safe. Ben, RWSA has reviewed the North Pointe Section 1E Initial Site Plan dated 11/8/21 by Collins Engineering and has the following comments. General Comments: RWSA will require a sewer flow acceptance prior to final site plan approval. The request will need to be sent to us by ACSA and will include the following: • Estimated average daily dry weather sewage flow (ADDWF) • Point of connection into RWSA system (which manhole) • Number of units/square footage • Estimated in-service date Let me know if you have any questions. Thanks, Dyon Vega Civil Engineer RIVANNAA WATERESEWERAUTN I;t Rivanna Water & Sewer Authority (434) 977-2970, Ext. 170 695 Moores Creek Lane Charlottesville, VA 22902 www.rivanna.ore "Effective October 1, 2021, please email devreview(cDrivanna.org for any correspondence related to Development Review. From: Matthew Wentland To: Ben H21S Subject: Planning Application Review for SDP202100085 NORTH POINTE APARTMENTS - SECTION IE = PHASE A - INITIAL - DIGITAL. Date: Thursday, December 16, 2021 10:03:00 AM The Review for the following application has been completed Application Number = SDP202100085 Reviewer = Matthew Wentland Review Status = Requested Changes Completed Date = 12/16/2021 This email was sent from County View Production. 1. The VSMP plan (WP0201600035) will need to be amended to show Erosion and Sediment Control and compliance with the approved plan (DEQ, drainage patterns, etc.). 2. Show the height of proposed retaining walls. Not all the proposed grading appears to tie in (particularly at the NE building with the three retaining walls). 3. Provide additional detail, such as spot elevations, to show runoff is directed away from buildings. SDP2021-85 North Pointe Apts, 1E Comments: CDD Inspections— Betty Slough bslouah@albemarle.ore 12-17-2021 Add the following note to the general notes page: 1. Retaining walls greater than 3 feet in height require a separate building permit. Walls exceeding 4 feet in height require a stamped engineered design also. Walls require inspections as outlined in the USBC. Add the following note to the general notes page: 2. Accessible parking spaces, access isles, and accessible route shall be installed in accordance with ICC ANSI A117.1-09 and the 2015 Virginia Construction Code. SDP2021-85 North Pointe Apts, 1E Comments: Fire/Rescue—Howard Lagomarsino hlaeomarsino@albemarle.org 12-15-2021 1. During construction, the following fire prevention steps are required, so please note them on the plan: a) Smoking shall be prohibited in areas where smoking makes conditions such as to make smoking a hazard and these areas shall be designated with no smoking signs per Virginia Statewide Fire Prevention Code. b) Areas where smoking can occur, shall have appropriate receptacles for discarded smoking materials per Virginia Statewide Fire Prevention Code. c) Per the Virginia Statewide Fire Prevention Code, vehicular access for firefighting shall be provided at all construction and demolition sites, provide access to within 100 ft. of temporary or permanent fire department connections, and have no overhead wiring or other overhead obstructions lower than 13 ft. 6 inches; this access may be via permanent or temporary road, but shall be capable of supporting fire apparatus in all weather conditions. d) Contractor shall ensure the street numbers are always plainly visible from the frontage street during construction per the Virginia Statewide Fire Code e) An approved water supply for firefighting operations shall be in place and available as soon as combustible materials arrive on site. f) Waste and combustible debris shall be removed from the building at the end of each day and disposed of in accordance with the Virginia Statewide Fire Code g) Fire extinguishers shall be provided, with not less than one approved fire extinguisher at each stairwell, on all floor levels where combustible materials have accumulated, in every storage and construction shed and in areas of special; hazards, such as where flammable and combustible liquids are stored or used, in accordance with the Virginia Statewide Fire Code h) Operations involving the use of cutting and welding shall comply with the Virginia Statewide Fire Prevention Code and shall require a permit from the Albemarle County Fire Marshal's Office 2. If the buildings require a sprinkler system, there is a hydrant needed within 100 feet of the fire department connection, the connection must have C & O threads, and the hydrant and FDC shall be arranged to allow use of each without obstructing fire appartus access 3. Please provide a note on the plans of the available fre flow for the hydrants From: Richard Nelson TO: Ben Hol Subject: SDP202100085 North Pointe Secbon 1E, Phase A (Digital) — Initial Site Plan Date: Friday, December 17, 2021 5:01:52 PM CAUTION: This message originated outside the County of Albemarle email system. DO NOT CLICK on links or open attachments unless you are sure the content is safe. Hi Ben, I recommend SDP202100085 North Pointe Section 1E, Phase A (Digital) — Initial Site Plan for approval with the following conditions: Submit utility drawings and water/sewer data sheets to ACSA. RWSA sewer capacity certification will be required. Certain dedication items for North Pointe Subdivision Section 1(easements and as-builts) should be completed prior to Utility Plan approval. Provide fixture counts for each building. Thanks, Richard Nelson Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (434) 977-4511 (Z) COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION Stephen C. Brich, P.E. 1401 East Broad Street Commissioner Richmond, Virginia 23219 November 30, 2021 Ben Holt County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Re: SDP-2021-00085 — North Pointe Apartments — Section lE — Phase A Review #1 Dear Mr. Holt: (804) 786-2701 Fax: (804) 786,2940 The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced North Pointe Apartments — Section lE — Phase A, as submitted by Collins Engineering, dated November 08, 2021 and find the following: 1. Please remove all Structure and Bridge Standard Details from the plans. S&B standard details are to be referenced in plan notes: The Standard Drawings contained in the VDOT Road & Bridge Standards are signed and sealed engineering drawings that are copyrighted materials of VDOT and the Commonwealth of Virginia. VDOT's policy is to offer the Standard Drawings in a secure electronic format and each Standard is available on this website. Plan assemblies using the Road & Bridge Standards shall reference each standard used. Inserting the Standard Drawings into VDOT, locality, or private development plan assemblies, or modifying the Standard Drawings in any way, is not permitted. For project specific applications, special design drawings based on VDOT standards shall include all details, notes, dimensions, and quantities necessary to completely construct the item. Roadside safety hardware standards (guardrail and concrete barrier) are crash tested devices and shall not be modified for project specific applications. 2. Retaining walls should be reduced in height due to potential impact on right of way along Thicket Run Place. Walls that appear to impact the R/W may require review/approval from District Structure & Bridge section. 3. Retaining wall foundations and support systems will not be within the proposed right of way. Please clearly show foundation in relation to R/W in details. VirginiaDOT.org WE KEEP VIRGINIA MOVING 4. Gutter pan should be shown in all areas that will convey water to inlet structures. 5. Drainage should not cross proposed entrances. Please show proposed drainage paths in plan view. 6. Mayberry Drive appears to be a private drive by streets note on sheet #1 and will need to be designated on the plan view. 7. Please provide profiles for the commercial entrances onto Northside Drive and Cliffstone Blvd. 8. Landscaping plan is required for review. 9. Sight distance profiles matching actual view per RDM Appendix F for entrances and intersections is required. 10. Please show the mail boxes & cluster box units per RDM Appendix B(1)-56 11. Please show trip generations for proposed units per rrE 10"' or latest edition. 12. Note that the final plan must show conformance with the VDOT Road Design Manual Appendices B(1) and F, as well as any other applicable standards, regulations or other requirements. 13. Please provide a comment response letter with each submission after the initial. A VDOT Land Use Permit will be required prior to any work within the right of way. The owner/developer must contact the Charlottesville Residency land Use Section at (434) 422-9399 for information pertaining to this process. If you have further questions please contact Max Greene at (434) 422-9866. Sincerely, Adam J. Moore, P.E. Area Land Use Engineer Charlottesville Residency Blue Ridge Health District ORUNJA DNARWtN1 Jk HEALTH J' �i i 4pE�Nt Nkl fO Ben Holt, Senior Planner I Albemarle County Community Development 401 McIntire Road Charlottesville, VA 22902 RE: North Pointe Section IE, Phase A Initial Site Plan SDP2021-85 Mr. Holt: �G 11 I� CharblhsYM/Alborrrode H*oNh DeporlmeW 1138 Rose HI Drive Chadoltesville, VA 22903 place• 434-972-6200 1 lox 434-972-4310 December 21, 2021 As requested, I've reviewed the subject plat, dated November 8, 2021, for the proposed development, referenced above. Since both water and sewer will be provided by ACSA, and there does not appear to be any existing onsite septic systems or private wells, I have no objections and recommend approval. If there are any questions or you wish to discuss, please give me a call, 434-972-4306. Sincerely, Alan Mazurowski Environmental Health Supervisor Blue Ridge Health District alan.mazurowski(c,vdh.vir ig nia.gov