Loading...
HomeMy WebLinkAboutSDP202100089 Review Comments Initial Site Plan 2021-12-22�q off nig 401 McIntire Road, North Wing Charlottesville, VA 22902-4579 County of Albemarle Telephone: 434-296-5832 COMMUNITY DEVELOPMENT DEPARTMENT WWW.ALBEMARLE.ORG ��BGIN�Q' Site Plan review Project title: Stonefield Towncenter Block C2-1 (SDP202100089), Initial Site Plan Project file number: SDP202100089 Plan preparer: John Beirne, PE, W W Associates / 968 Olympia Drive, Suite 1 Charlottesville, VA 229111 ibeime(a),,wwassociates.netl Owner or rep.: OCT Stonefield Property Owner, LLC, 230 Royal Palm Way, 2nd Floor Palm Beach, FL, 33480 [ odesai(a),oconnorco.com ] Plan received date: 29 Nov 2021 Date of comments: 22 Dec 2021 Plan Coordinator: Kevin McCollum Reviewer: John Anderson Engineering has reviewed this initial site plan and offers these review comments. SDP202100089. Stonefield block C2-1 1. CI: May require parcel data be revised, if TMP 061 WO-03-00-019A5 is an accurate tax map reference for development parcel. 2. General a. WPO (Amendment) approval is prerequisite to ESP approval for this development. Please submit a WPO plan Amendment at earliest convenience (common plan of development; criteria 2C, if no increase in rate /volume of storm runoff, from initially permitted values). Amend corresponding WPO plan for this section of Stonefield (initially permitted as Albemarle Place). b. Note: If development proposes an increase in volume or rate of storm runoff above those initially permitted with Albemarle Place, then this project is subject to 2B technical design criteria (SWM). c. List associated WPO plan/s on sheet C-L d. Show runoff conveyance (roof leader lines, for example). Confirm no new storm system pipes or inlets are proposed or required. Provide LD-204, stormwater inlet computations, and LD-229, storm sewer design computations, as needed. 3. C=6: Please label TMP 061 WO-03-00-019A5, the parcel underdevelopment. 4. C-7 a. Confirm if existing parking spaces fronting wall at Northrop Grumman are to remain as active parking spaces. b. Label parking lot drive aisle width at its narrowest point, outside proposed building garage access. c. Confirm if 2-way traffic along parking aisle outside the proposed parking garage, between Northrop Grumman and first floor parking garage access, persists. If 2-way movement persists: i. Provide auto -turn figures for sedans approaching the first floor garage access from either direction, exterior to the garage, and with vehicles entering and exiting, simultaneously, without conflict, with 1'-2' min. clearance (2' preferred) between vehicles. ii. Recommend mirrors mounted at garage entry to expand field of vision for vehicles entering or exiting first floor access. Recommend mirror at 2"d floor garage access. iii. Clarify whether a waste management vehicle will tip dumpster located in dumpster enclosure, since physical constraints prevent this. Multiple conflicts are apparent if design intent is for a typical waste management vehicle to tip dumpster located within enclosure. Please avoid service /passenger vehicle conflict/s at first floor garage entry. d. Provide auto -turn figures for second floor parking garage access, identical with auto -turn figures for first floor garage access. Auto -turn figures should show 2"d floor access width sufficient for 2 sedans arriving (enteringlexiting) simultaneously, with sufficient clearance to avoid conflict. Engineering Review Comments Page 2 of 2 (Sedans have been discontinued by at least one major North American automaker, with SUVs, vans, and trucks now the dominant share of vehicles sold in the U.S.) At a minimum, ensure 1' clearance (via Autotum figures) for typical passenger sedans at 1 n/2"d floor garage points of entry. e. Three parking spaces are shown beneath the garage 2°d floor access. Confirm that no (new) vertical /horizontal members (beams/girders) will obstruct or impede use of (or displace portion of) these 3 Ex. parking spaces. Ramp may cantilever above spaces, in which case, conflict may be avoided. f Ensure proposed exterior access door meets ADA requirements for landing, clearance, etc. Please ensure outward opening will not strike a passing pedestrian. Design should provide measure of assurance that a pedestrian passing immediately outside the door is not vulnerable to door strike. g. Label sidewalk width (adjacent to Bond Street), narrowest dimension. h. Provide a stop bar for vehicles exiting the first -floor garage access. i. Recommend elevated (4"-6") concrete landing (or similar measure) at first floor garage access as calming measure to limit vehicle speed for vehicles that may bypass garage access to use parking southeast of 286' parking lot aisle (distance to District Ave). Physical constraints, active parking, limited sight lines at garage exit, parking areas beyond garage entrance present potential conflicts and a hazard at first floor garage access. Vehicle -pedestrian proximity, inattention, etc. appear to have contributed to a pedestrian fatality at Stonefreld, at a crosswalk at District and Bond, in 2016. Please feel free to call if any questions: 434.296-5832 -x3069 ( landerson2(a),albemarle.or ). Thank you I Anderson SDP202I00089 StonefieldTowncenter blockC2-1 ISP 12222Ldoc