Loading...
HomeMy WebLinkAboutSDP202100077 Plan - Revision 2022-01-11vi v� �I 1 1 a 5� VIRGINIA SETBACKS AND BUILDING HEIGHT C-1 COMMERCIAL ZONING DISTRICT 1RY2020 aeemane Coanly, vA Code or 0 ifaoces Sec. 4.20-Setbacks and stepbacks in conventional commercial and industrial districts. Setbacks and stepbacks shall be provided as follows: a. Conventional commercial districts. The following shall apply within the C-1, CO, and HC districts: Setbacks Front -Minimum 10 feet from the right-of-way or the exterior edge of the sidewalk if the sidewalk is outside of the right-of-way; for off- street parking or loading spaces, 10 feet from any public street right-of-way Front -Maximum 30 feet from the right-of-way or the exterior edge of the sidewalk if the sidewalk is outside of the right-of-way, provided that this maximum setback shall not apply to any structure existing on June 3, 2015 and to any structure depicted on an approved final site plan that is valid on June 3, 2015 as having a front setback greater than 30 feet; none, on any lot, including a corner lot, abutting a principal arterial highway or interstate Side and Rear -Minimum If the abutting lot is zoned residential, rural areas, or the Monticello Historic district: (i) no portion of any structure, excluding signs, shall be located closer than 50 feet from the district boundary; and (4) no off-street parking or loading space shall be located closer than 20 feet to the district boundary. If the abutting lot is zoned commercial or industrial, any primary structure shall be constructed and separated in accordance with the current edition of the Building Code. Side and Rear -Maximum None Figures Figures 1 through 6 are for illustration purposes only. If there is a conflict or inconsistency between a regulation in section 4.20 to which a Figure pertains and the Figure itself, the regulation is controlling. In addition, Figures 1 through 6 merely illustrate specific requirements and do not show all applicable requirements of the applicable district regulations. Figure 1 Figure 2 Sec. 21.4 - Height regulations. Except as otherwise provided in section 4.10structures may be erected to a height not to exceed 65 feet. The minimum stepback requirements for any story that begins above 40 feet in height or for each story above the third story, whichever is less, in height shall be as provided In section 4.20. (4 20-21.4, 12-10-80; 9-9-92; Ord, 15-18(4), 6-3-15; Ord, 11171(-1818(4)_, 8-9-17) SDP202100077 A MINOR SITE PLAN AMENDMENT TO PREVIOUS SDP202000062 FOR DS TAVERN ALBEMARLE COUNTY, VIRGINIA LINEAGE JOB #19066 INDEX OF SHEETS DESCRIPTION SHEET NO. VICINITY MAP (SCALE 1:2000) FIRM INFO: Lineage Architects, P.C. P.O. Box 991 SITE 98Lee Highway Verona, VA 24482 Phone: (540)248-3771 Fax: (540)248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: TH OF wWA UJONATHAN F. GARBER> TITLE HEFT C-01 No. 038568 GENERAL NOTES .............. C-02 01/10/22fl SIONAL E��S EXISTINGCONDITIONS.................................................................. ............... C-03 EXISTING ZONING, SETBACKS, AND EASEMENTS ................................................... C-03 A OVERALL SITE PLAN C-04 LANDSCAPING PLAN (BY OTHERS) .. .. .. .. .. .. .. C-04 A SANITARY SEWER PLAN ............................... ................... ...... C-04 B SITE LIGHTING PLAN ............................................... ................ .................... C-04 C SANITARY FORCE MAIN PROFILE ...... ..................... ............... C-04 D WONN 1 ■ ♦,1 ■ ■ 1 ■ ■III ■ ■ ■ 1 k ■ 1 • ■ ■ 1 k 1 1 ■ 1 ■ XIMA HANDICAP PARKING LAYOUT & CONSTRUCTION DETAILS C-06 A LANDSCAPING DETAILS ................ ..... C-07 GENERAL PROPERTY INFORMATION PROPOSED USE: BUILDING ADDITION FOR 3100 S.F. OF OFFICE SPACE. 9 ADDITIONAL PARKING SPACES. OWNER: IVY ROAD RE LLC. 1. TAX MAP : 059000000015AO 2. ZONING: a. PROPERTY IS SPLIT -ZONE C-1 COMMERCIAL AND RA RURAL AREA b. PROPERTY IS LOCATED WITHIN THE ENTRANCE CORRIDOR OVERLAY DISTRICT c. PROPERTY IS SUBJECT TO PROFFERS PER ZMA198400026 d. PROPERTY HAS CRITICAL STEEP SLOPES 3. MAGISTERIAL DISTRICT: SAMUEL MILLER DISTRICT 4. WATERSHED: SOUTH FORK RIVANNA WATER SUPPLY WATERSHED 5. THE PROPERTY IS NOT LOCATED WITHIN THE ACSA JURISDICTIONAL AREA AND DOES NOT HAVE ACCESS TO PUBLIC WATER/SEWER. 6. DATUM REFERENCE: BENCHMARK AXLE 1534.90' PROPERTY INFORMATION FOR TMP 59-15A1 OWNER: IVY ROAD RE LLC. 1. TAX MAP : 059000000015A1 2. DB REFERENCE: 5123/91 DESIGNER: LINEAGE ARCHITECTS, P.C. ATTN: JON GARBER P.O. BOX 991 98 LEE HIGHWAY VERONA, VIRGINIA 24482 PHONE: (540) 248-3771 DEVELOPER: 704 CAPITAL, LLC 7 SIGNATURE PANEL: DEPARTMENT OF COMMUNITY DEVELOPMENT: PLANNING & ZONING ENGINEERING INSPECTIONS ARCHITECTURAL REVIEW BOARD DEPARTMENT OF FIRE AND RESCUE ALBEMARLE COUNTRY SERVICE AUTHORITY VIRGINIA DEPARTMENT OF TRANSPORTATION HEALTH DEPARTMENT APPROVAL DATE 7 1 COMMENTS 11/10/20221 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: TITLE SHEET I. ----------- i i �I 3■ A i GENERAL NOTES: 1) ANY DISCREPANCIES FOUND BETWEEN THE DRAWINGS AND SPECIFICATIONS, AND SITE CONDITIONS OR ANY INCONSISTENCIES OR AMBIGUITIES IN DRAWINGS OR SPECIFICATIONS SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER IN WRITING WHO SHALL PROMPTLY ADDRESS SUCH INCONSISTENCIES OR AMBIGUITIES IN WRITING. WORK DONE BY THE CONTRACTOR AFTER HIS DISCOVERY OF SUCH DISCREPANCIES, INCONSISTENCIES, OR AMBIGUITIES WITHOUT CLARIFICATION FROM THE ENGINEER OF RECORD, SHALL BE DONE AT THE CONTRACTOR'S RISK. 2) THE LOCATION OF EXISTING UTILITIES AS SHOWN IS APPROXIMATE ONLY. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL PUBLIC OR PRIVATE UTILITIES WHICH LIE IN OR ADJACENT TO THE CONSTRUCTION SITE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING, AT HIS EXPENSE, ALL EXISTING UTILITIES DAMAGED DURING CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE TEST PITS AT ALL LOCATIONS WHERE PROPOSED CONSTRUCTION CROSSES EXISTING WATER, GAS AND FIBER OPTIC LINES. 3) THREE BUSINESS DAYS PRIOR TO ANY EXCAVATION CALL MISS UTILITY. 4) ALL CONSTRUCTION IS TO BE IN ACCORDANCE WITH LOCAL AUTHORITY STANDARDS AND SPECIFICATIONS. 5) WORK IN THIS PROJECT SHALL CONFORM TO THE LATEST EDITIONS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT) ROAD AND BRIDGE SPECIFICATIONS, THE VDOT ROAD AND BRIDGE STANDARDS, THE VIRGINIA EROSION AND SEDIMENT CONTROL REGULATIONS AND APPLICABLE STANDARDS OF ALBEMARLE COUNTY. IN THE EVENT OF CONFLICT BETWEEN ANY OF THESE STANDARDS, SPECIFICATIONS OR PLANS, THE MOST STRINGENT SHALL GOVERN. ALL UTILITIES TO BE DEDICATED TO THE ALBEMARLE COUNTY MUNICIPAL WATER SYSTEM SHALL BE CONSTRUCTED AND TESTED TO CONFORM TO COMMONWEALTH OF VIRGINIA/ STATE BOARD OF HEALTH WATERWORKS AND/OR SEWERAGE REGULATIONS AND THE ALBEMARLE COUNTY DESIGN AND CONSTRUCTION STANDARDS MANUAL. 6) DRAINAGE IMPROVEMENTS SHALL BE INSTALLED IN ACCORDANCE WITH STANDARDS AND SPECIFICATIONS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION. 7) INSTALLATION OF CONCRETE STORM PIPE SHALL COMPLY WITH VDOT STANDARD DRAWING PB-1. 8) ALL RIGID PIPE BEDDING (CONCRETE, CEMENT LINED DUCTILE IRON PIPE, ETC.) SHALL BE CLASS C, UNLESS NOTED OTHERWISE ON THE PLANS. 9) ALL UNDERGROUND FACILITIES LOCATED WITHIN THE VDOT RIGHTS -OF -WAY SHALL BE INSTALLED PRIOR TO THE PLACEMENT OF ANY PART OF THE PAVEMENT STRUCTURE. 10) ALL MATERIALS USED FOR FILL OR BACK -FILL SHALL BE FREE OF WOOD, ROOTS, ROCKS, BOULDERS OR ANY OTHER NON -COMPACTIBLE SOIL TYPE MATERIAL. UNSATISFACTORY MATERIALS ALSO INCLUDE MAN-MADE FILLS AND REFUSE DEBRIS DERIVED FROM ANY SOURCE. 11) SATISFACTORY MATERIAL FOR USE AS FILL FOR PUBLIC STREETS INCLUDE CLASSIFIED IN ASTM D-2487 AS GW, GP, GM, GC, SW, SP, SM, SC, ML, AND CL GROUPS. THE MOISTURE CONTENT SHALL BE CONTROLLED WITHIN PLUS OR MINUS 2 PERCENTAGE POINTS OF OPTIMUM TO FACILITATE COMPACTION. GENERALLY, UNSATISFACTORY MATERIALS INCLUDE MATERIALS CLASSIFIED IN ASTM D-2487 AS PT, CH, MH, OL, OH AND ANY SOIL TOO WET TO FACILITATE COMPACTION. CH AND MH SOILS MAY BE USED SUBJECT TO RESULTS OF THE GEOTECHNICAL REPORT AND UPON APPROVAL OF THE SUPERVISING ENGINEER. SOILS SHALL HAVE A MINIMUM DRY DENSITY OF 92 LB/CU. FT. PER ASTM D-698 AND SHALL HAVE A PLASTICITY INDEX LESS THAN 17. 12) MATERIALS USED TO CONSTRUCT EMBANKMENTS FOR ANY PURPOSE, BACK - FILL AROUND DRAINAGE STRUCTURES OR IN UTILITY TRENCHES OR ANY OTHER DEPRESSION REQUIRING FILL OR BACK -FILL SHALL BE COMPACTED TO 95% OF MAXIMUM DENSITY AS DETERMINED BY THE STANDARD PROCTOR TEST AS SET OUT IN ASTM STANDARD D-698. THE CONTRACTOR SHALL, PRIOR TO ANY OPERATIONS INVOLVING FILLING OR BACKFILLING, SUBMIT THE RESULTS OF THE PROCTOR TEST TOGETHER WITH A CERTIFICATION THAT THE SOIL TESTED IS REPRESENTATIVE OF THE MATERIALS TO BE USED ON THE PROJECT. TESTS SHALL BE CONDUCTED BY A CERTIFIED MATERIALS TESTING LABORATORY AND THE CERTIFICATIONS MADE BY A LICENSED PROFESSIONAL ENGINEER REPRESENTING THE LABORATORY. 13) COMPACTION OF FILL MATERIAL UNDER BUILDING SLABS SHALL BE BASED UPON RECOMMENDATIONS OF SOILS ENGINEER AFTER COMPLETION OF STANDARD PROCTOR TEST AND SHALL MEET BEARING REQUIREMENTS OF ARCHITECT FOR BUILDINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING. 14) EMBANKMENT FILL AND TRENCH BACK -FILL SHALL BE PLACED IN LIFTS AT A MAXIMUM UNCOMPACTED DEPTH OF 8-INCHES AND 6-INCHES, RESPECTIVELY. DENSITY TESTS SHALL BE CONDUCTED AT THE FOLLOWING MINIMUM FREQUENCIES: (A) EMBANKMENTS FOR ROADS, STREETS, DAMS, ETC.: ONE TEST PER LIFT PER 10,000 SQUARE FEET OF LIFT. (B) BACK -FILL AROUND STRUCTURES AND IN TRENCHES: ONE TEST PER LIFT PER 500 LINEAL FEET OF TRENCH. 15) COMPACTION TESTS FOR STREET PAVEMENT STRUCTURE SHALL BE MADE IN CUT AND FILL AREAS AT THE FOLLOWING MINIMUM FREQUENCIES: (A) SUB -GRADE: ONE TEST PER LANE PER 500 LINEAL FEET. (B) STONE -BASE: ONE TEST PER LANE PER 6" COMPACTED LIFT PER 500 LINEAL FEET. (C) HOT ASPHALTIC CONCRETE: ONE TEST PER LANE PER LIFT PER 500 LINEAL FEET. ABREVIATIONS: ARCH. ARCHITECT 16) ALL EXCAVATIONS, INCLUDING TRENCHES, SHALL BE KEPT DRY TO PROTECT C/L OR C L CENTERLINE THEIR INTEGRITY. C/OUT OR C/O CLEAN OUT CONC. CONCRETE 17) TEST RESULTS SHALL BE SUBMITTED TO THE SUPERVISING ENGINEER. FAILURE TO CONDUCT CG CURB & GUTTER DENSITY TESTS SHALL BE CAUSE FOR NON -ACCEPTANCE OF THE FACILITY. TESTS DIA. DIAMETER SHALL BE CONDUCTED AT THE SOLE COST OF THE DEVELOPER OR HIS AGENT. E.P. EDGE OF PAVEMENT EL. ELEVATION 18) NOT USED. ESMT. EASEMENT EW EXISTING WATER 19) NOT USED. EX. EXISTING F.E. FOUNDATION ELEVATION 20) NOT USED. F.E.S. FLARED END SECTION F.F.E. FINISHED FLOOR ELEVATION 21) INSPECTORS HAVE FULL AUTHORITY TO REJECT FILL OR BACKFILL MATERIALS, F.H. or F/HYD FIRE HYDRANT REQUIRE UNDERCUTTING OR SUBGRADE STABILIZATION, REQUIRE PROVISIONS FOR SUB- F/L FIRE LINE DRAINAGE, OR REQUIRE OTHER MEASURES WHICH AFFECT THE INTEGRITY OF ROAD AND F.W. TOP OF FOUNDATION WALL UTILITY CONSTRUCTION. FAILURE TO COMPLY WITH INSPECTOR'S DIRECTIVES SHALL BE G.V. GATE VALVE CAUSE FOR NON -ACCEPTANCE OF THE FACILITY. HORIZ. HORIZONTAL INV. INVERT 22) TRAFFIC CONTROL ON PUBLIC STREETS SHALL BE IN CONFORMANCE WITH THE MANUAL IRS IRON ROD SET OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). LAT. LATERAL LT. LEFT 23) A PRECONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE ISSUANCE OF THE LAND M/H MANHOLE DISTURBING PERMIT. THE CONTRACTOR SHALL ARRANGE THE MEETING WITH THE MIN. MINIMUM COUNTY ENGINEER. ALBEMARLE COUNTY PUBLIC UTILITIES INSPECTOR, REPRESENTING NE NORTH EAST WATER INTERESTS, SHALL ALSO ATTEND. ATTENDANCE SHALL BE COORDINATED THROUGH NW NORTH WEST THE OFFICE OF THE COUNTY ENGINEER. P.C. POINT OF CURVEP.I. POINT OF INTERSECTION 24) RETAINING WALLS GREATER THAN 3' IN HEIGHT REQUIRE A SEPARATE BUILDING PERMIT. WALLS P.T. POINT OF TANGENT EXCEEDING 4' IN HEIGHT REQUIRE A STAMPED ENGINEERING DESIGN ALSO. WALLS REQUIRE PVC POINT OF VERTICAL CURVE INSPECTIONS AS OUTLINED IN THE USBC. PVI POINT OF VERTICAL INTERSECTIONPVT POINT OF VERTICAL TANGENT 25) ACCESSIBLE PARKING SPACES, ACCESS AISLES, AND ACCESSIBLE ROUTES SHALL BE INSTALLED IN PVMT. PAVEMENT ACCORDANCE WITH ICC ANSI A117.1-09 AND THE 2015 VIRGINIA CONSTRUCTION CODE. R RADIUS R.D. ROOF DRAIN 26) BUILDING OR STRUCTURES BUILT BEFORE JANUARY 1, 1985 MUST HAVE AN ASBESTOS SURVEY RT. RIGHT PERFORMED IN ORDER TO APPLY FOR A PERMIT. ASBESTOS REMOVAL PERMITS ARE REQUIRED SAN. SANITARY SEWER IF POSITIVE FOR SUCH FROM ALBEMARLE COUNTY AND VDOLI. CONTACT VDOLI FOR ADDITIONAL SEW. or SSEW. SEWER REQUIREMENTS AND PERMITS FOR DEMOLITION PROJECTS. STD. STANDARD STM. SEW. STORM SEWER 27) ALL ROOF DRAINS SHALL DISCHARGE IN A MANNER NOT TO CAUSE A PUBLIC NUISANCE AND NOT SE SOUTH EAST OVER SIDEWALKS. SW SOUTH WEST S/W SIDEWALK 28) ALL HANDICAP PARKING SPACES AND ACCESS ISLES SHALL COMPLY WITH ADA STANDARDS OF S.F. SQUARE FEET ACCESSIBILITY. ACCESSIBLE PARKING SPACES AND ACCESS ISLES SHALL NOT HAVE A SURFACE STIR. STRUCTURE SLOPE GREATER 1:48. ACCESS ISLES SHALL BE AT THE SAME LEVEL AS THE PARKING SPACE THEY T.B. TOP OF BANK SERVE. SEE SHEET C-05 FOR SPOT ELEVATIONS DETAILING CROSS SLOPES FOR ACCESSIBLE T/C TOP OF CURB T/P TOP OF GRAVEL PAVEMENT EXISTING PROPOSED ROAD CENTERLINE CURB TAPER SIDEWALKS CONCRETE PAVEMENT El GRAVEL SURFACE BUILDINGS FENCE DECIDUOUS TREE CONIFEROUS TREE CONIFEROUS SHRUB st ST STORM WATER LINE PROPERTY LINE STORM SEWER - 2900 - - - - 2988 - - INDEX CONTOUR - - - 2898 - - - - - - 2898 - - - INTERMEDIATE CONTOUR 2876.3 X 2883M _1_" SPOT ELEVATION LIMITS OF CLEARING AND/OR GRADING PARKING SPACES AND ADJACENT ACCESS ISLES. SEE SHEET C-06 FOR DETAIL OF ACCESSIBLE TPD WATER SERVICE AND METER TRIPS PER DAY SIGNAGE. U/G UNDERGROUND VERT. VERTICAL - SANITARY SEWER LATERAL AND CLEANOUT W/L WATERLINE ss SS SANITARY SEWER LINE X-ING CROSSING ohe ❑HE OVERHEAD ELECTRIC LINE uge UGE UNDERGROUND ELECTRIC LINE oht ❑HT OVERHEAD TELECOM LINE VDOT General Notes ug t UGT UNDERGROUND TELECOM LINE V1. All work on this project shall conform to the current editions of and latest revisions to the Virginia Department of Transportation (VDOT) Road and Bridge Specifications and Standards, the Virginia Erosion and Sediment Control Regulations, and any other applicable state, federal or local regulations. In case of a discrepancy or conflict between the Standards or Specifications and Regulations, the most stringent shall govern. w W WATER LINE V2. All construction shall comply with the latest U.S. Department of Labor Occupational Safety and Health Administration OSHA and Virginia Occupational Safety & Health VOSH Rules and Regulations. P Y P P Y (OSHA), r9 P Y ( ) 9 gas GAS GAS LINE VDOT General Notes (Continued) V3. When working within VDOT right-of-way, all traffic control, whether permanent or temporary, shall be in accordance with the current edition of VDOT's Work Area Protection Manual. A transportation management plan needs to be submitted for approval and land use permit issued prior to any execution of work within the VDOT right of way. V17. The installation of any entrances and mailboxes within any dedicated street right-of-way shall meet VDOT minimum design standards and is the responsibility of the developer. V4 The developer shall be responsible for relocating, at his expense, any and all utilities, including traffic signal poles, junction boxes, controllers, etc., owned by VDOT or private I public utility companies. It is the sole responsibility of the V18. Prior to VDOT acceptance of an streets all required street si na a and/or pavement markings shall be installed b the developer in accordance with the Manual On Uniform Traffic P y q 9 9 P 9 y p developer to locate and identify utility facilities or items that may be in conflict with the proposed construction activity. VDOT approval of these plans does not indemnify the developer from this responsibility. Control Devices. V5. Design features relating to field construction, regulations, and control or safety of traffic may be subject to change as deemed necessary by VDOT. Any additional expense incurred as a result of any field revision shall be the responsibility V19. The developer shall provide the VDOT Land Development Office with a list of all material sources prior to the start of construction. Copies of all invoices for materials utilized within any of the developer. dedicated street right-of-way must be provided to the local VDOT Land Development Office prior to acceptance of the work. Unit and total prices may be obscured. V6. If required by the local VDOT Land Development Office, a pre -construction conference shall be arranged and held by the engineer and/or developer with the attendance of the contractor (s), various County agencies, utility companies and V20. Aggregate base and subbase materials shall be placed on subgrade by means of a mechanical spreader. Density will be determined using the density control strip in accordance with VDOT prior to initiation of work. Section 304 of the VDOT Road and Bridge Specifications and VTM-10. A certified compaction technician shall perform these tests. Certified copies of test reports shall be submitted to V7. The contractor shall notify the local VDOT Land Development Office when work is to begin or cease for any undetermined length of time. VDOT requires and shall receive 48 hours advance notice prior to any required or requested VDOT daily, unless specified otherwise. In addition to checking stone depths, a VDOT representative shall be notified and given the opportunity to be present during the construction inspection. and testing of the density control strip. V8. The contractor shall notifythe Traffic Operations Center at 540 332-9500 for an traffic control Ian that impacts a VDOT maintained Interstate or Prima roadway to provide notification of the installation and removal of the work zone. P ( ) Y P P Primary Y P V21. Asphalt concrete pavements shall be placed in accordance with Section 315 of the VDOT Road and Bridge Specifications. Density shall be determined using the density control strip as specified in Section 315 and VTM-76. A certified compaction technician shall perform these tests. Certified copies of test reports shall be submitted to VDOT daily, unless specified V9. The contractor shall be responsible for maintaining a VDOT permitted temporary construction entrances in accordance with Section 3.02 of the Virginia Erosion and Sediment Control Handbook. Furthermore, access to otherproperties P 9 P P ry O r9� otherwise. A VDOT representative shall be notified and given the opportunity to be present during the construction and testing of the control strip. affected by this project9 shall be maintained through construction. V22. In accordance with Section 302.03 the foundations for pipe culverts thirty-six 36 inches and larger shall be explored below the bottom of the excavation to determine the a and PP( ) r9 P type V10. Contractor shall ensure adequate drainage is achieved and maintained on the site during and at the end of construction. condition of the foundation. The contractor shall report findings of foundation exploration to the engineer and VDOT for approval prior to placing e. Foundation designs shall comply P 9 P 9 pP P p 9 P 9 P y r with VDOT Road and Bridge Standard PB-1. Where soft, yielding, or otherwise unsuitable foundation is encountered, the foundation design and/or need for foundation stabilization shall V11. All water and sewer lines within existingor proposed VDOT right-of-way shall have a minimum thirty-six 36 inches cover and when possible shall be installed under roadway drainage facilities at conflict points. P P 9 Y rtY- () P Y 9 be determined by the engineer and approved by VDOT. V12. Any unusual subsurface conditions (e.g., unsuitable soils, springs, sinkholes, voids, caves, etc.) encountered during the course of construction shall be immediately brought to the attention of the engineer and VDOT. Work shall cease in V23. VDOT Standard Guardrail shall be installed where warranted and/or as proposed on these plans in accordance with VDOT's installation criteria. Final approval of the guardrail layout to that vicinity until an adequate design can be determined by the engineer and approved by VDOT. be given by VDOT after grading is mostly complete. V13. All fill areas, borrow material and undercut areas shall be inspected and approved b a VDOT representative rior to lacement of fill. A VDOT representative shall be resent to insure the soil sample(s)obtained for CBR's is P pP YP PP V24. Approval of these plans shall expire five (5) years from the date of the approval letter. representative of the location. When soil samples are submitted to private laboratories for testing, the samples shall be clearly identified and labeled as belonging to a project to be accepted by VDOT and that testing shall be performed in V25. VDOT Standard CG-12 Curb Ramps shall be installed where indicated on these plans and/or as specified by VDOT. accordance with all applicable VDOT standards and procedures. V14. All roadwayfill base su rade material and backfill in unlit /storm sewer trenches shall be compacted in accordance with the lift thicknesses density and moisture requirements as specified in the current VDOT Road and Bride b9 Y P Y q P 9 V26. The foundations for all box culverts shall be investigated by means of exploratory borings advanced below proposed foundation elevation to determine the type and condition of the Specifications. Certified copies of test reports shall be submitted to VDOT daily, unless specified otherwise. foundation. The contractor shall submit copies of borehole logs and report findings of foundation exploration to the engineer and VDOT for approval prior to constructing box. Foundation designs shall comply with VDOT Road and Bridge Standard PB-1. Contrary to the Standard, where rock is encountered and cast -in -place box is proposed, the thickness of V15. VDOT Standard CD and UD underdrains shall be installed where indicated on these plans and/or as specified by VDOT. bedding shall be six (6) inches. Where soft, yielding, or otherwise unsuitable foundation is encountered, the foundation design and/or need for foundation stabilization shall be V16. A post installation visual/video camera inspection shall be conducted b the Contractor on all es identified on the Tans as storm sewer pipe and a select number of a culverts. For a culverts, a minimum of one pipe installation P P Y PP P PP PP PP PP determined by the engineer and approved by VDOT. for each size of each material type will be inspected or ten percent of the total amount for each size and material type summarized. All pipe installations on the plans not identified as storm sewer pipe shall be considered as culvert pipe for inspection purposes. Additional testing may be required as directed by the Area Land Use Engineer or their representative. FIRM INFO: Lineage Architects, P.C. P.O. Box 991 98 Lee Highway Verona, VA 24482 Phone: (540) 248-3771 Fax: (540)248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: 401,TH op-0 U JONATHAN F. GARBER s No. 038568 S01 /10/2240 �`SjOIVAL S� w a a H 0 w � � z U > F U U O 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: GENERAL NOTES DRAWING NUMBER: C 02 c BENCHMARK \\11Tj AXLE _ + ELEVATION %�n3 3 534.90' DEMOLISH AND REMOVE CRAPE MYRTLE x3 DOGWOOD x2 \` DOGWOOD ARBORVITAE SCREEN 8" EVERGREEN MAGNOLIA TM 59-16A IVY HILL GARDENS, LLC DEMOLISH AND REMOVE MIXED DECIDUOUS BED DB 5002/71 RURALAREA MULTI -FAMILY RESIDENTIAL DEMOLISH AND REMOVE CONCRETE PATH +I\ ARBORVITAE SCREEN HEMLOCK ROW / +&I\` . . . . . . F {- BRICK RETAINING WALL MAX HEIGHT: 2.00' + DEMOLISH AND I OVERHEAD ELE( DECIDUOUS MAGNOLIA - DEMOLISH AND REMOVE / WOOD PATH EDGE T � ONE STORY HOUSE / DOOR 527,91' 1303 SF 41I/ y a ' � 1 I / I / 1 I I I I /v II I I •1 CTl1DV DICTnDII WOODED SLOPE � ` MIX OF DECIDUOUS ' ' ' ' ' AND EVERGREEN y/ STONE RETAINING WALL CRITICAL SLOPES .. MAX HEIGHT: 3 00' / O • . , • • , ,DEMOLISH AND REMOVE POWER POLE /. . . . . . . . 54p0p�,,`, 5 nFMOI LRH ANn /:.� . ............�. ;:. ...00 ... .. z.............. .. : z 11.. 1. ..................... j T.....................:,�...... / .. / 2 .................... ....• s . . . . . . . . . . . S�Op.� ............... � I -,�BLAC " \ .................. = .................. ................ \ TM 59-15A ............... . IVY ROAD RE, LLC DB 5123/91 RURAL AREA / C1 COMMERCIAL ;' T Inst 201800013717 T FEMA Flood Zone X 51003CO265D, 2/4/05 Samuel Miller Magisterial District ­00� U J i i c 13141, TI TM 59-15B K HALLAM ROTH DB 4263/729 ^I RURALAREA 41NrI F FAN411 Y RF41f1FNTIAI 34" TULIP POPLAR IVY ROAD US ROUTE 250 80.00' R.O.W. N87° 08'39'W 86.82' TM 59-15 JERRY D BENINATE DB 1654/396 RURALAREA RESIDENTIAL -MOBILE HOME CRAPEMYRTLEx2 _525.00 / GENERAL NOTES: 1. CURRENT FIELD SURVEY RECORDED BY LINEAGE ARCHITECTS, PC ON OCTOBER 28, 2019 AND JULY 7, 2021. 2. BULK TOPOGRAPHY SHOT IN FIELD BY LINEAGE ARCHITECTS, PC (SEE NOTE 1). SEPTIC TOPOGRAPHY BASED ON COUNTY GIs. 3. THE SITE IS DETERMINED TO BE LOCATED WITHIN THE IVY CREEK RESERVOIR WATERSHED. 4. THE SITE IS SPLIT -ZONED C1 COMMERCIAL AND RA RURAL AREA. 5. THE SITE IS LOCATED IN FEMA FLOODPLAIN ZONE X; THE SITE IS DETERMINED TO BE OUTSIDE THE 100 YEAR FLOOD PLAIN. FIRM MAP NUMBER: 510 03C 0265 D. EFFECTIVE DATE: FEB. 4, 2005 6. NO STRUCTURE, EITHER EXISTING OR PROPOSED, EXCEEDS 65 FEET IN HEIGHT PER SECTION 21.4 OF THE ALBEMARLE COUNTY ZONING CODE. 6. BENCHMARKS AND ELEVATIONS ARE RELATIVE TO VIRGINIA NORTH ZONE 4501. 7. ALL PLANT MATERIAL IS UNDER 6" CALIPER UNLESS OTHERWISE NOTED. 8. ALL TREES NOT EXPLICITLY SHOWN FOR DEMOLITION SHALL BE PRESERVED. 9. ALL DEMOLISHED MATERIAL IS To BE REMOVED To LANDFILL. EASEMENTS OF RECORD: \ (EASEMENTS AS KNOWN OR DISCLOSED, NO TITLE REPORT FURNISHED, ADDITIONAL EASEMENTS OR UTILITIES MAY OR MAY NOT EXIST.) VIRGINIA ELECTRIC AND POWER COMPANY EASEMENTS: \ \ DB 307/183 POLE LINE EASEMENT PARALLEL TO RT. 250, No WIDTH GIVEN. -NOT PLOTTED \ DB 316/562 POLE LINE EASEMENT PERPENDICULAR To RT. 250, NO WIDTH \ GIVEN. -NOT PLOTTED ELECTRIC EASEMENT RESERVATIONS: .. \DB 263/230 RESERVATION FOR AN EASEMENT FOR POWERLINE CROSSING PROPERTY. NO WIDTH GIVEN. LOCATION NOT SPECIFIED, NOT • • • • • • • PLOTTABLE. .. DB 263/440 RESERVATION FOR AN EASEMENT FOR POWERLINE CROSSING `• • • • • • • • • • • • • • • . PROPERTY. NO WIDTH GIVEN. LOCATION NOT SPECIFIED, NOT PLOTTABLE. VIRGINIA TELEPHONE AND TELEGRAPH EASEMENTS: DB 338/415 POLE LINE EASEMENT, 10' IN WIDTH CENTERED ON WIRES AS BENCHMARK CONSTRUCTED. NO LOCATION SPECIFIED. NOT PLOTTED. N PIN ELEVATION DB 338/424 POLE LINE EASEMENT, 20' IN WIDTH CENTERED ON WIRES AS 1523.31' CONSTRUCTED. No LOCATION SPECIFIED. NOT PLOTTED. IPA WATERLINE EASEMENT: DB 357/219 RIGHTS TO A WELL AND WATERLINE, IN EXCHANGE FOR A RELEASE TO RIGHTS TO A SPRING. ACCESS EASEMENT: DB 263/440 A 20' WIDTH EASEMENT FFOR ACCESS, OVER THE "OLD D.S. ROAD", SHOWN HEREON ON THE WESTERN SIDE OF THE PROPERTY. DB 4491/396 A SHARED DRIVEWAY EASEMENT SHOWN HEREON. AREA OF RESTRICTED USE: DB 263/230 AREA DEFINED TO BE KEPT FREE OF BUILDING OR PENS OF ANY KIND; TO BE USED ONLY FOR GARDENS AND PASTURE (EXCEPTING FOR HOGS OR GOATS). SHOWN HEREON. a 8 8 %< H %0 � " LI"E AT .'NEIGNT 510 535 5M S TLINEAT3.5'NEIG, �hl10.0A0 i32 _ - STrt��E 532 B B 121 0 2a 20 y SIGHT DISTANCE PROFILE AT IVY ROAD EXISTING CONDITIONS AND DEMOLITION PLAN SCALE: 1` 20' GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. FIRM INFO: Lineage Architects, P.C. P.O. Box 991 98 Lee Highway Verona, VA 24482 Phone: (540) 248-3771 Fax: (540)248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: 4 1,TH OF, v JON�. GARB No. 038568 S01 /10/2240 �`SjOIVAL S� w a a � U w a H 0 W � � U > cY r^�, U O 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: EXISTING CONDITIONS AND DEMOLITION PLAN DRAWING NUMBER: C-03 3L n y00 5' RIGHT-OF-WAY DB 263/440 I I I I I I I II I I I I J I I I I I I I I I I I I I I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I U I I iI 1 I I 1 �— (U ` \y\Ci� J � ONING EXISTING I STORY g HOUSE 11035f �1p. FFE 547 91 0,q .3- E%ISTING BRICK PATIO EXISTING 2RY HISTORIC TAVERN 181t SF FFE EZ5.91 s PROPOSED I TprcuolT x t STORY usS G EpsnBLDG ADDITION rtEsx.w D.GF W95F v.PATX Ere. szs.sr FFE 53853 IPONEMFPxO (AT REM ENTRANCE) NSTALLSRIGNPAUU AND LAN GSGPING- GEBOR0TG1XER I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I l i l I I I I I I I I I I I I I I I I I I I I I I I I ( I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ( I I I I I I I I I I I I I I I I I I I I I I I l I I I I I I I I I I I I I I I I I I TO BE KIND PASNRE KEPT RE E EOF BE USED (E USED (EXCEPTING UI EDMEO BUILDINGS Y ONLY 36FOR FOR FOR HOGS =0HOG5OR DENS OR BAND GOATS) OF MY TS BLDG O l I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I Bill . I I I I I I I I I I I I I l I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I l I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I l I I I I I I I I I I I I I I I I I I I I I I I I I I I I I l I I I I I I I I I I I I I I I I I I I I I I I I I I I l I I I I I I I I I I I I I I I I I I I I I I I I I I I l I I I I I I I I I I I I I I I I I I I I I I I I I I l I I I I I I I I I I I I I I I I I I I I I I I l I I I I I I I I I I I I I I I I I I I I I I l I I I I I I I I I I I I I I I I I I I I l I I I I I I I I I I I I I I I I I l I I I I I I I I I I I I I I I I l I I I I I I I I I I I I I I I GRAPHIC SCALE 30 0 15 30 40 60 ( IN FEET ) 1 inch = 30 ft. EXISTING ZONING AND EASEMENTS SCALE: 1 "=20' CO y \ V1 IVY ROAD o�°'G/ IT US ROUTE 250 IA 80.00' R.O.W. W �rq (iN� z / ti�OJ���j QF'�Aryo 0 "IN . � O(§Z�PG�• T i E=4 EXISTING 1 STORY ` I FIRM INFO: Q HOUSEOUSE Lineage Architects, P.C. P.O. Box 991 98 Lee Highway ExlsiPATOING RICK EXISTING 35TORY \ Verona, VA 24482 �O HISTORICTAVERN � Q.'� 161E SF \ v��Q' FFE S]8.9A Phone: (540)248-3771 PoxO � PROPOSED v�oDsrn ErclsnaLOGE` Fax: (540) 248-1628 / ADDITION RIBS.� 1b9E , Email: info@lineageazch.com 9795� .lAW FFE 53B83 MEwerrtSAaM EAT REAR NTRANCE) NXTALLBOGNPATO \\ �(\ ENGINEER NAME/SEAL: T AND IGNBYG ING / OEBIGNBY OMER CRITICAL SLOPES // 7. / / / // / / / C& � . LTH O1FF' ��•)(� / � 1 / / / / / / T � �Eweuw rJ JONATHAN F. GARBER a 0 \` No. 038568 S01 /10/22 CRITICAL SLOPES O SjONAL E� \� yARos aFR4?o W \ / z 0 n M U l GRAPHIC SCALE N 30 0 15 30 40 7 COMMENTS 1/10/2022 EXISTING BUFFERS AND SETBACKS 6 COMMENTS 11/5/2021 ( IN FEET) SCALE: 1"=20' 1 inch = 30 ft. 5 MINORAMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: EXISTING ZONING, SETBACKS, AND EASEMENTS DRAWING NUMBER: C-03 A PARKING CALCULATIONS TABLE AS PER 18-4.12.6 OFFICES, BUSINESS, ADMINISTRATIVE AND PROFESSIONAL (INCLUDING MEDICAL OFFICES BUT NOT DENTAL CLINICS) REQUIREMENT: 1 SPACE / 200 SF OF GROSS COMMERCIAL OFFICE SPACE WHERE GROSS COMMERCIAL OFFICE SPACE= 80% OF THE NET SF OF THE BUILDING FOOTPRINT OR AT THE REQUEST OF THE APPLICANT, THE ACTUAL NET OFFICE FLOOR AREA AS SHOWN ON FLOOR PLANS SUBMITTED BY THE APPLICANT, DELINEATING THE ACTUAL NET OFFICE FLOOR AREA, WHICH PLANS SHALL BE BINDING AS TO THE MAXIMUM NET FLOOR AREA USED. NET SF OF OFFICES ONLY: 2,396 sf 22396 =11.95 =12 00 TOTAL SPACES REQUIRED = 12 (INCLUDING 1 H/C) TOTAL SPACES PROVIDED = 12 (INCLUDING 1 H/C) INSTALL FLAGPOLE INSTALL 2' PVC ELECTRIC CONDUIT / /\ O V °� 6328.50 $F9� OUTPUT FROM ROOF AND INSTALL STEPPING STONES/.. •' E PER DETAIL 1IC-06 FOUNDATION DRAINS OF \ STRUCTURE, 4"YARD �� INLET TO 90° ELBOW / HANDICAP PARKING AND ACCESS AISLE '```���� SEE DETAIL 1/C-06 A R3.00 INSTALL BRICK PAVERS GRADE: 524.15, I \ 1so PER DETAIL 3/C-06 INV. OUT: 520.77 I INSTALL ADA COMPLIANT / GRAVEL 580. 0 SF X PER DETAIL 2IC-06 2� / Oc�rG� EXISTING 1 STORY .00 HOUSE ayQit� 1303 SF 7047 $� .00 / P' FFE 527.91 S , ti tf�. E �y 'RESERVED OWNER 8p0 A E PARKING' SIGN E INSTALL SCREENING FENCE _Oq / G \ 5.00 SEE DETAILS I AND 21 C-04A 44.0 HVAC EXISTING BRICK INSTALL BRICK PAVERS E <C EXISTING 2 STORY -06 \� PATIO PER DETAIL 3/CR2.00 �O v R1F#� HISTORIC TAVERN 1612 SF ItJADA ACCESSIBLE PATH40 FFE 526.94 C EMERGENCY ACCESS 4.0 D PROPOSED \ DISTANCE g 87, 0 PROPOSED 15TORV PDORION I 2 STORY 4855E ADDITION FFE 5M.60 K01 POND TO REMAIN \ 979 $F A FROM PATO) IN -GROUND PROPANE TANKS FFE 526.83 YARD INLET TO COLLECT (AT REAR OUTPUT FROM ROOF AND '\�1 ENTRANCE) EXISTING STONE RETAINING WALL, TO REMAIN FOUNDATION DRAINS [(.�4\ 9 \ A YEa MAX HEIGHT: 3.01Yj STRUCTURE,OF 1pn AND LANDSCAPING. 8' BRONZENZENYLNYLOPLAST Y DROP -IN GRATE TO c _ 8" NYLOPLAST TEE / . / CRITICAL SLOPES T/ TOP:526.05 Pff INV. / OUT: 52 EXISTING EXISTING BIRD / CAGE,REMAIN 45* 45° ELBOW j �� �' / BLDG (INSTALL 8' PVC STORM PIPE \/ 127.50' @ / OW 45° ELBOW 1' PVC CONDUIT 3' PVC CONDUIT CRITICAL SLOPES GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. 8' PVC A PIPE END INV. OUT: 520.,' �. 2' PVC CONDUIT SHARED DRIVEWAY ACCESS EASEMENT (SEE SHEET C-03 A) INSTALL KNOX BOX CONTRACTORS TO COORDINATE WITH ONE ANOTHER OVERALL SITE PLAN J::f,_E: =20 GENERAL NOTES: / , Cn 1. ALL RADII = 5' UNLESS NOTED OTHERWISE. W 2. ARCHITECTURAL BUILDING DIMENSIONS SUPERSEDE BUILDING DIMENSIONS AS W SHOWN ON THIS PLAN. � 3. PAVEMENT AT ALL ENTRANCES SHALL MATCH THE EXISTING CROSS SECTION OF ROUTE 250. 4. THERE WILL BE NO CHANGE IN THE EXISTING POINT OF INGRESS TO, OR EGRESS FROM, THE SITE. p� 5. THE MAXIMUM IMPERVIOUS SURFACE AREA ONSITE IS 3100 SF(0.07 ACRES). W 6. PROPOSED SITE USE IS COMMERCIAL OFFICE ONLY. THERE WILL BE NO RETAIL USE, EITHER GIFT, CRAFT, ANTIQUE SHOP, OR OTHERWISE. Z TOTAL ACREAGE OF PROPOSED USE = 0.06 ACRES W TOTAL NUMBER OF EMPLOYEES = 4 7. NO SITE LIGHTING IS PROPOSED FOR PARKING AREAS. U 8. THERE ARE NO ADDITIONAL EASEMENTS PROPOSED FOR THE SITE. (za 9. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE J4 ELIMINATED. 10. ALL ROOF DRAINS SHALL DISCHARGE IN A MANNER NOT TO CAUSE PUBLIC NUISANCE U AND NOT OVER SIDEWALKS. P4 11. ALL ACCESSIBLE PARKING SPACES AND ACCESS ISLES SHALL CONFORM WITH ADA DESIGN STANDARDS FOR ACCESSIBILITY. CROSS SLOPES OF ACCESSIBLE PARKING SPACES AND ADJACENT ACCESS ISLES SHALL NOT EXCEED 1:48. ACCESS ISLES SHALL FIRM INFO: BE AT THE SAME LEVEL AS THE PARKING SPACES THEY SERVE. Lineage Architects, P.C. 12. ORDINANCE 18-4.12.13(C): LOADING SPACE. THE LOW LEVEL OF ON -SITE STAFF AS WELL P.O. 991 98 Leea HHighighway AS THE INTENDED USE OF THE OFFICE AS A SPACE FOR MANAGING LOCAL ASSETS Verona, VA 24482 WILL NOT GENERATE THE SIZE OR QUANTITY OF DELIVERIES TO THE BUILDING SUCH THAT A LOADING SPACE WOULD BE NECESSARY. THESE FACTS IN COMBINATION WITH Phone: (540) 248-1621 THE OWNER'S INTENTION TO MAINTAIN THE HISTORIC CHARACTER OF THE SITE, LEAD Email: info@lineagearch.com THE REQUEST THAT THE LOADING SPACE REQUIREMENT BE WAIVED VIA 18-4.12.13(F). I ENGINEER NAME/SEAL: I _A.&A _ 13. MAINTAIN 8" CLEARANCE ABOVE FINAL GRADE FOR ALL NON -MASONRY MATERIALS. � LTH ojQ'P D �V FIRE FIGHTING INFORMATION: UJON�. GARBER>- No. 038568 1. AVAILABLE FLOW AT HYDRANT NO. 12796 = 2796 GPM 0�01 /10/22� 2. NEEDED FIRE FLOW = 1500 GPM 1 SjONAL E a. F = 1.5 WOOD FRAME b. A = 2842 SF c. C =1439 GPM =1500 GPM d. 0 = 0.85 (C-2 OFFICE) e. X = 0.12 f. P = 0.0 WEEKLY TRIP CALCULATIONS: NOTE: INTENDED SITE USE IS LOW VOLUME COMMERCIAL PER APPENDIX F OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD DESIGN MANUAL. IS Tavern Summary of Trip Generation Calculation For 4 Employees of General Office Building June 09, 2020 Average Standard Adjustment Rate Deviation Factor Driveway Volume Lail 7 vva WF H' a Avg. Weekday 2-Way Volume 3.32 2.16 1.00 13 7-9 AM Peak Hour Enter 0.42 0.00 1.00 2 7-9 AM Peak Hour Exit 0.06 0.00 1.00 0 7-9 AM Peak Hour Total 0.48 0.71 1.00 2 4-6 PM Peak Hour Enter 0.08 0.00 4-6 PM Peak Hour Exit 0.38 0.00 4-6 PM Peak Hour Total 0.46 0.70 Saturday 2-Way Volume 0.54 0.80 1.00 1.00 1.00 1.00 0 2 2 2 Li-i �1 �. U 666q Saturday Peak Hour Enter 0.05 0.00 Saturday Peak Hour Exit 0.04 0.00 Saturday Peak Hour Total 0.09 0.31 1.00 1.00 1.00 0 0 0 F FV O� /� CN U U Note: A zero indicates no data available. Source: Institute of Transportation Engineers Trip Generation, 7th Edition, 2003. TRIP GENERATION BY MICROTRANS Summary of Trip Generation Calculation For 1.73 Th.Gr.Sq.Ft. of General Office Building 7 COMMENTS 1/10/2022 June 17, 2020 Average Standard Adjustment Rate Deviation Factor Driveway Volume 6 COMMENTS 11/5/2021 Avg. Weekday 2-Way Volume 11.01 6.13 1.00 19 5 MINORAMNDMNT 8/9/2021 7-9 AM Peak Hour Enter 1.36 0.00 1.00 2 7-9 AM Peak Hour Exit 0.19 0.00 1.00 0 4 PERMIT SET 12/30/20 7-9 AM Peak Hour Total 1.55 1.39 1.00 3 3 CO. COMMENTS 12/10/20 4-6 PM Peak Hour Enter 0.25 0.00 1.00 0 4-6 PM Peak Hour Exit 1.24 0.00 1.00 2 4-6 PM Peak Hour Total 1.49 1.37 1.00 3 Saturday 2-Way Volume 2.37 2.08 1.00 4 2 COMMENTS 8/18/20 Saturday Peak Hour Enter 0.22 0.00 Saturday Peak Hour Exit 0.19 0.00 1.00 1.00 0 0 NO. REVISIONASSUE DATE Saturday Peak Hour Total 0.41 0.68 1.00 1 JOB NUMBER: 19066 Note: A zero indicates no data available. DATE: MAY 26,2020 Source: Institute of Transportation Engineers Trip Generation, 7th Edition, 2003. TRIP GENERATION BY MICROTRANS DRAWN BY: JMT AVERAGE DIRECTION OF TRIPS APPROVED BY: JFG DIRECTIONAL FACTOR FOR US 250 FROM DICK WOODS RD. TO US 29 :.689 DRAWINGDESCRJPTION: AVERAGE DAILY DRIVEWAY VOLUME: 19+13 = 32+2 = 16 OVERALL SITE PLAN DRIVEWAY VOLUME x DIRECTIONAL FACTOR: 16 x .689 = 11 DRAWING NUMBER: EAST -BOUND DAILY TRIPS : 11 WEST -BOUND DAILY TRIPS: 5 C-04 PLANTED COVER AND HARDSCAPING IN THE STREAM BUFFER: 1. EXISTING SHRUB COUNT: 18 2. PROPOSED SHRUB COUNT: 23 3. EXISTING PLANTED COVER: 1,265 SF 4. PROPOSED PLANTED COVER: 2,792 SF 5. EXISTING HARDSCAPE AREA: 2,034 SF 6. PROPOSED HARDSCAPE AREA: 1,648 SF ARBORVITAE HEDGE + 8 SMOOTH WITHEROD \`\Ij,+%I\\\ DOGWOOD + 3 REDCEDAR \\I + I\�` DOGWOOD �, I \ 3 SWEETSHRUB 1 HOLLY 2 BOTTLEBRUSH BUCKEYE \ +�ttl\\ +'�I\�\ 3 BAYBERRY DOGWOOD 8" Ev. MAGNOLIA 2 SWEETSHRUB e + 1 SHUMARD OAK \\ I/ + +'� I \\\ +// I \\\ O+ / + /L O oa 51 / ST. JOHNSWORT------------, �( r / 3 SWEET SHRUB Dec. MAGNOLIA ADA COMPLIANT GRAVEL GRID EXISTING 1 STORY HOUSE 1303 SF FFE 527.91 6 OAKLEAF HYDRANGEA 8 PLUM YEW 1 WITCHHAZEL O \ +'/� I \\\ CRITICAL STEEP SLOPES \ \ t r I I f f / GRAVEL DRIVE -ST. JOHNSWORT AND PARKING 1 HOPHORNBEAM\ O EXISTING 2 STORY HISTORIC TAVERN 1612 SF FFE 526.94 34' TULIP POPLAR FLAGPOLE DOGWOOD 5 SPICEBUSH lT .,I —OW OAK 2 FRINGETREE I i i 2BAYBERRY 2 SWEETSHRUB ST. JOHNSWORT 4 BOXWOOD GRASS 51 • • ��i�j�j�j�j�j�j�j�j�j�j�j�j •� ., �I�I��I�I�I�I�I�I�I�I`. v-i�i� AND LANDSCAPING - 1 , 3 SWEETBAY 1 YELLOWWOOD - ST. JOHNSWORT 2 CRAPE MYRTLE 4 ACUBA \ 1�0 EXISTING 1 ST( BLDG 230 SF FFE: 525.87 (REAR ENTRAIN / / County of Albemarle Conservation Plan Cheeklist — To be placed on Landscape Plans (Handbook, pp 111-284-111-297 for complete specifications) 1. The following items shall be shown on the plan: ❑ Trees to be saved; ❑ Limits of clearing (ouWde ddpline oftrees to be saved); ❑ Locstionund type of,armaticefersmg; ❑ (mde change requiring tree wells orwalls; ❑ Proposed trenching or tmmeling beyond the limits ofelearing. 2. liarkioce: ❑ All trees b be saved shall be marked with print or ribbon at a height clearly visible to equipment operator. ❑ No grading shall begin unfit the one marking has been inspected and approved by a County Inspector. 3. Pre -Construction Conference: ❑ Trcc preservation and protection measures shall be reviewed with the contractor on site. 4. Equipment Operation and Sturvee: ❑ Heavy equipment, vehicular traffic and smmge ofconstrucfiun materials including soil shall not be permitted within the driplines oftrees to be saved. 5. Soil Erosion and Stormwater Detention Devices: ❑ Such devices shall not adversely affect trees m be saved. 6. Fires. ❑ Fires arenotpemritred within 100 fectofthedriptineo£trees lobe saved. 7. Toxic Materiels: ❑ Toxic materials shall not be stored within 100 licit ofe dripline oftreas to be saved. & Protective Fencing: ❑ Trees W be retained within 40 feet ofaproposed building or grading activity shall be protected by fencing. ❑ Fencing shall be in place and shall be inspected and approved by a County inspector prior to grading or construction. 9. Tree wells: ❑ When the ground level mostbe raised within the dripline ale one, In be saved, a tree well shall be provided and a construction detail submitted fun approval. 10. Tree walls: ❑ When the ground level must be lowered within the dripline a mew be saved, a tree wall shall be provided; and a construction detail submitted for approval. 11. Trenching and Tunneline: ❑ When trenching is inquired within the limits of clearing, it shall be done as far away from the tanks of tees an possible. Tunneling under a large tree shall be considered as an alterative when it is anticipated that necessary trenching will destroy feeder mots. 12. Cleanu P, ❑ Protective fearing shall be the last items removed dudug the final cleanup. 13. Damaged Trees: ❑ Damaged trees shall be treated immediately bypnming, fcnilinstion or other methods recommended by a tee specialist NOTE: IT IS TID: DEVELOPER'S RESPONSIBILITY TO CONFER WTrH THE CONTRACTOR ON TREE CONSERVATION REQUIREMENT& SST. JOHNSWORT / / 1 STEWARTIA 1 BLACKHAW SWEETBOX O k\ WINTER JASMINE / '--1 SPICEBUSH \\--2 SWEETSHRUB rA —4 RHODODENDRON —2 BLl + 20 6 VIBURNUM DOGWOOD 1 HOLLY LANDSCAPING PLAN SCALE: 1 "=10' GRAPHIC SCALE ( IN FEET ) 1 inch = 20 ft. PLANTING SCHEDULE Botanical Name Common Name oty. Size Root O.C. LARGE TREES Cladrastis kentuckea Yellowwood 1 2-2.5" cal B&B III opaca American Holly 2 8-10' ht B&B VIF Juniperus virginiana Eastern Redeedar 3 6-8' ht B&B VIF Magnolia virginiana Sweetbay Magnolia 3 6-8' ht B&B VIF Ostrya virginiana Hophornbeam 1 2-2.5" cal B&B Quercus shumardll Shumard Oak 1 2-2.5" cal B&B SMALL TREES Chionanthus virginicus Fringetree 2 4-6' ht B&B VIF Lagerstoremia indica Natchez' Natchez Crapemyrtle 2 8-10' ht B&B Stewartia monodelpha Tall Stewartia 1 8-10' ht B&B Viburnum prunifolium Blackhnw Viburnum 3 6-8' ht B&B SHRUBS Aesculus parviflora Bottlebrush Buckeye 3 5 gal Cont VIF Aucuba japonica 'Emily Rose' Emily Rose Aucuba 4 3 gal Cont VIF Buxus sempervirens'Suffruticosa' English Boxwood 4 36" ht/spr B&B VIF Calycanthus floridus Aphrodite' Aphrodite Sweetshrub 9 34' ht Cont VIF Cephelotaxus harringtonia Duke Gardens' Duke Gardens Plum Yew 8 3 gal Cont VIF Hamemelis intermedia Arnold Promise' Arnold Promise Witchhazel 1 54 ht Cont Hydrangea quercifolia 'Sike's Dwarf Sike's Dwarf Oakleaf Hydrangea 6 5 gal Cont VIF Lindera benzoin Spicebush 5 3 gal Cont VIF Myrica pensylvanica Northern Bayberry 10 5 gal Cont VIF Jasminum nudiflorum Winter Jasmine 584 sf 3 gal Cont VIF Rhododendron chinoides Chinoides Rhododendron 4 5 gal Cont VIF Viburnum nudum 'Winterthur' Winterthur Smooth Witherod 8 4-6' ht Cont VIF Viburnum pragense Prague Viburnum 9 5-6' ht Cont VIF GROUND COVER, PERENIALS, VINES, GRASS Hypericum calycinum St. John's Wort 1550 sf 1 gal Cont 18" oc Sarcococca humilis Sweetbox 115 sf 1 gal Cont 24" oc 4x4 PT POST CLAD IN 1x CEDAR ABOVE GRADE x4 CEDAR LATTICE, " SPACING, HORIZONTALS "0 OUTSIDE IOTTOM RAIL TO BE SET 3" MINIMUM ABOVE GRADE GRADE 44 PT POST SET IN CONCRETE LATTICE SCREEN ELEVATION SCALE: 1 /2" = V-0" C-04 NOTES: 1. SIDE PANEL TO DISMOUNT OR BE SET ON HINGES TO ALLOW FOR MAINTENANCE. 2. LATTICE SCREEN TO BE STAINED PER OWNER'S SPECIFICATION. CHAMFER 4 SIDES OF POST TOP AT 30 " 26 CEDAR TOP RAIL PEAK TOP 1/2" 4x4 PT POST CLAD IN 1x CEDAR ABOVE GRADE 1x4 CEDAR LATTICE, 2" SPACING, HORIZONTALS TO OUTSIDE 2x6 CEDAR FRAME GRADE 4x4 PT POST SET IN CONCRETE LATTICE SCREEN SECTION SCALE: 1 /2" = 1'-0" C-04 TREE CANOPY SITE AREA: 85,537 SF 10%REQUIRED CANOPY: 8,553.70 SF 51%EXISTING CANOPY: 43,834 SF PARKING LOT LANDSCAPING PARKING LOT AREA: 1,328.50 SF 5%REQUIRED LANDSCAPING: 316.425 SF 29%PROVIDED LANDSCAPING: 2,281 SF \I PLANT HEALTH NOTE ALL SITE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED TO REACH, AND SHALL BE MAINTAINED AT, MATURE HEIGHT. 80 THE TOPPING OF TREES IS PROHIBITED. TREES AND SHRUBS SHALL BE PRUNED MINIMALLY AND ONLY TO SUPPORT THE OVERALL HEALTH OF THE PLANT. FIRM INFO: Lineage Architects, P.C. P.O. Box 991 98 Lee Highway Verona, VA 24482 Phone: (540)248-3771 Fax: (540)248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: � LTH Op G U JONATHAN F. GARBER v No. 038568 1 /10/22� �sIONAL a 5 U � a w H a w � � (;n U 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMEER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: LANDSCAPING PLAN DRAWING NUMBER: C-04 A 1,000 GAL. TOP SEAM CONCRETE PUMP TANK, ORENCO MVP S1/2 DM, ZOELLER E191 - SEE A DETAILED SEPTIC PLANS T� BY OTHER 1,000 GAL. TOP SEAM — CONCRETE SEPTIC TANK, 24" RISERS/LIDS,/ r ZABEL A300 12x20-VC-BALL SS / 4" SCH. 40 PVC CLEANOU r SS� J / 2" SCHEDULE 40 PVC 5 s FORCE MAIN/ 5 u / / 0 v 5�� EXISTING 1 S g HOUSE 1 1303 SF FIE 5271 L �(\ EXISTING BRICK PATIO J / O� 5 QPv U I CRITICAL SLOPES S ROUTE FORCE MAIN OUTSIDE OF CRITICAL SLOPES AREA MAINTAIN MINIMUM 24" COVER ALONG ENTIRE LENGTH OF FORCE MAIN, SEE SANITARY PROFILE 2" SCHEDULE 40 PVC FORCE MAIN u 2" SCH. 40 PVC v MANIFOLD LATERAL, V131, TYP. 4 SEE DETAILED SEPTIC PLANS, T BY OTHER it "C"—MINIMUM SPACING OF TRENCHES MOUND ABOVE GRADE TO fALLOW FOR SETTLEMENT ZVDH x. EARTH /PPROVED CRUSHED ROCK r FILTEREAN COARSE GRAVEL TO 3/4' NO FINES tn SCH 40 LPD PIPE m TYPICAL SECTION al 780 SQFT OF DRAINFIELD REQUIRED ZONE 1 — 4 TRENCHES 65 FOOT LONG J NOTES: DIVERT SURFACE RUNOFF FROM ENTERING TRENCHES. L NO REDUCTION IN AREA FOR SUBSTITUTED SYSTEM ALLOWED n i u LDP TRENCH SECTION SCALE: NTS J - 7 1" PVC TO IT CLOSET FOR / SEPTIC ALARM / VB2, TYP. 4 MOUND ABOVE GRADE TO ALLOW FOR SETTLEMENT �., NIMUM SPACING OF TRENCHES EARTH BACKFILL FILTER CLOTH 1 1 1/4" SCH 40 LPD PIPE A— EZ FLOW BUNDLES 4 HERI-URAIEU HIRE 780 SOFT OF DRAINFIELD REQUIRED ZONE 1 — 4 TRENCHES 65 FOOT LONG NOTES: DIVERT SURFACE RUNOFF FROM ENTERING TRENCHES. NO REDUCTION IN AREA FOR SUBSTITUTED SYSTEM ALLOWED INSTALL ORAINFIELD PER PLANS LDP TRENCH SECTION (AL SCALE: NTS EXISTING SEPTIC TANK - TO BE ABANDONED IN PLACE AND GROUTED FULL /Is —..—.s-.,..—xE ..—. Is 0 EXISTING SEPTIC LINES AND TANKS TO BE ABANDONED APPROX. LOCATION EXI% SANITARY LINES - TO BE i0 ABANDONED IN PLACE CRITICAL SLOPES GRAPHIC SCALE 10 20 40 Manifold / (24' deep) SEPTIC PLAN SCALE: 1 "=20' ( IN FEET ) 1 inch = 20 ft. Valve box 6' ROUNOVALVE BDValve box FINISH GRADE BRICK SUPPORT�� (THREE) I1I� 36 GRAVEL 3/16' holes @ 5' DC First hole @ 2.5' 52 holes per Lod zone @ 6 o clock position 3 holes per lateral LDP LATERAL SECTION SCALE: NTS OFFICE PLAN VIEW USE SILICON ADHESIVE BETWEEN RISER JOINTS a I I TO 2" ABOVE GRADE WITH EZ SET POLY RISERS CONSEALCS-102 AND LID (ASTM C-9 OFFICE HIGH PRESSURE (ASTM 1227)(AS1 SECTION VIEW W 4" SCH 40 PVC CLEANOUT CAP GRASS TRAFFIC RATED CLEAN OUT COVER 5 r TRAFFIC SURFACE LPD E'Mlln. • PUMP TANK W P" 4 I � r_l RECED Z CONCRETE / W 3000 PSI CONCRETE / 4" SCH 40 PVC PIPE •h z SCREW DOWN RISERS WITH STAINLESS STEEL SCREWS 4"X4"SCH 40 PVC WYE • � V HIGH PRESSURE SEATS TRAFFIC AREA NON TRAFFIC AREA 1227) (ASTM 923) LPD W PUMP r TANK SANITARY CLEANOUT SECTION �� ZABEL MDO-12x20 VC -BALL EFFLUENT'FILM SCALE: NTS C-04B EXTEND HANDLE TO UNDERSIDE OF RISERLID GENERAL NOTES: NOTES: 1. SEPTIC TANK IS NEW 1,000 GALLON TOP SEAM CONCRETE TANK 2- INLET -PER VDH SEWAGE DISPOSAL and HANDLING BEGS 3. OUTLET WITH EFFLUENT FILTER 4. TANKS PENETRATIONS MUST BE WATERPROOFED AND NOT LEAK 5. 24" RISER ON INLEVOUTLET SIDE OF TANK. 6. TANK SHALL BE H2O RATED WITH H2O CAST IRON RISER IF LOCATED IN TRAFFIC AREA. 11000 GAL. TOP SEAM SEPTIC TANK , SCALE: NTS C-04 Soup all piping to tank with plastic straps and stainless steel anchors CONSEALCS-102 (ASTM C-990) SEPTIC TANK HIGH PRESSURE SEALS (ASTM IU7)(ASTM923) 2" UNION, 2" BALL VALVE FIRM INFO: 1. SEE APPROVED PLANS BY OLD DOMINION ENGINEERING DATED MARCH 23, 2021. 2. ALL PVC TO BE SCHEDULE 40 UNLESS NOTED OTHERWISE.. Lineage Architects, P.C. P.O. Box 991 3. NO FALL IN LDP TRENCHES. 98 Lee Highway 4. PLACE PRESSURE RELEASE VALVE AT ANY INTERMEDIATE HIGH POINTS IN FORCE Verona, VA 24482 MAIN. Phone: (540)248-3771 Fax: (540)248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: LTH OF J JONATHAN F. GARBER a No. 038568 — 01 /10/22�4' ti Leave exna Flom and > Pump wrung coaled in riser - - St ONAL 24" Minimum Opening BRING TO 2- ABOVE GRADE SCREW DOWN RISERS WITH WITH EZ SET POLY RISERS STAINLESS STEEL SCREWS AND LID \ / HIGH PRESSURE SEALS (ASTM 1227) (ASTM 923) 2"snh 40 Pvc Waterproof LPD junctionH.—-�DRAINFIELD seal conduit with non hardening sealer Highlevelalarm Boat IT' Non-eorrasive lift rope Check Valve IT Pllh1P On 30" 3/16 vent hole \\\\1 PVC Floral Tree PUMPOFF 23" Redundant Off/ "^ Low Level Alarm 19" 1000 Gallon Mid Seam Concrete Tank Zoeller EI91 Effluent Pump 45 gpm Orenco MVP S1/2 DM NOTES: 1. PUMP TANK IS TOP SEAM 1000 GALLON CONCRETE TANK 2. INLET'- 4" SCH 40 PVC TEE 3. TANKS PENETRATIONS MUST BE WATERPROOFED AND NOT LEAK 4. 24- POLY RISER ON OUTLET SIDE OF TANK. 5. STRAP ALL PIPING TO TANK WITH PLASTIC STRAPS AND STAINLESS STEEL ANCHORS 6. FLOAT HEIGHTS WILL NEED TO BE ADJUSTED IF TANK DIMENSIONS VARY FROM 21.64 GALLONS PER INCH 7. EASY ACCESS TO VALVES AND UNIONS LDP DOSING PUMP TANK SECTION SCALL: 1, First 3/16" hole is 2.5' from stare of trench m•.�-•TT 12. n Star) of Trench —� Manifold is 24" deep see site plan for manifold size Valve box 1 MANIFOLD TO TRENCH SCALE: NTS 1.25" SCH40 PVC BALL VALVE for restricting flow TRIM AROUND PIPE VALVE BOX 1 SCALE: NTS 1000 Gallon Concrete Top Seam Tank 21.64 gal/in (Hanover Mid Seam) Easy access to valves and unions Flora[ heights will need to be adjusted if lank dimensions vary fmm 21.64 gaVin 6I Round Valve Box i" SCH 40 PVC _XTENSION SEPTIC TANK 24^(min)auto PVC LPD DEAINFIELD on 1000 GALLON MID SEAM CONCRETE TANK LDP DOSING PUMP TANK PLAN SCALE: NTS 1 1/4' SCH 40 PVC SLID to Female Threaded 1 1/4' SCH 40 PVC Threaded Cap L 1/4' V Elbow VALVE BOX 2 10 SCALE: NTS C-04B LEI F4 5 U O � H x w y F U 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION SEPTIC PLAN AND DETAILS LEGEND SYMBOL CALLOUT LUMINAIRE TEMP. OUTPUT QTY. A 2700 KELVIN 980 LUMENS li A AUTHENTIC DESIGN - COLONIAL ASHLEY HOUSE WALL MOUNT T B 2700 KELVIN 980 LUMENS F DEEP LANDING WORKSHOP - L1316B SCONCE ^ C 2700 KELVIN 490 LUMENS VA WA L LANITERN NGSTON T i D 2 ANN MORRIS- MORRIS LIGHT 2700 KELVIN 980 LUMENS T E AURORA LIGHT - QUADRANT -3W 3000 KELVIN 210 LUMENS 31 T F HYDREL-ASPEN LED-30` 2700 KELVIN 580 LUMENS 7 =,I LIGHTING CUT SHEETS r s� O AUTHENTIC DESIGNS The ANM RLrd We,, Board, \'emwn105776 Colonial Ashley House Coach'i Mount Lantern - FA SM-LTA5-&W BULB SPECS: 2W Wen Maximum El2BWba 2700"Idah FINISH: Lahmed Tape CLASS: swammFaae UL LISTED FOR OUTDOOR USE VAUGI AN Kingsi Wall Imtem - FC All HaMXea Brous WQ131RZVX Zinc WA0131 ZLU% Build SPeLMeathen Bulb Base EI2 Candelabra Base Max Wattage 4M Bulb Supplied No Vaughan Recommends LED2700005001m For a brighter light, a bulb with a higher lumen output can be used. ormodorU Furable er Suiroblekr outdoor use. WA0131 US vemwn AC l DS LISTED Please Note: -These noresaretorguidance only. Vaughan accepn no responsibility he any installation using the above notes The final declslon on Installation remalniwithlhe miroller. vaughandesigns.com DEEP LANDING WORKIFICHE, Pull d�pl­dDii,i gm, L-16138 - FB Is hy" high v ID were s s 4,^ deep Projects 6'1 Two canulates(Elog erckHa 60 watt max eeda(ought Ke1.dn UL LuhJ LEE, Hord"' Email, 4 EM431 dark lead rant chime, Glass is GLRST, M1mrd made dNmmmon N. A N N— M O R R 1 5 N E W Y O K K 239 EAST BOTH STREET, NEW YORK, NY 10022 TEL: 212 75S3306 F0X: 212 8384955 EMNL: iaoCanrtmoms.mm WEBSITE: wwxanDmonismm MORRIS LIGHT-ED FINISH: STATUARYBRONZE BE DIMIETER X 4• DEPTH LIMPING: (2)SOCKETS PER FMBE- UP TO 40 WATTS PER Si OR UP T060 WATTS PERSOCKET LED MEBASE: MEDIUM BME(E26) 2700K ILL LISTED FOR DUTTON USE A auroraTght TEPPE G.....sa- The Lai is a classic design engineered and manWaMW to a quaiiry and performance standard neveloe avaua°ie Featuring a hears, army armhdeauamaaa sera ingenioxaryeoaple] mmerohudaie�aramae. hood vMh no vlaibie hardwam. Available In two distributions and wattages. FeaumindUde: 3 Wan Sin Is LED or 7 Wad Tdple LED Up10250lumens a 3000K • Can, X i High Density LED(CRI 80W 21 BID890 CRI) or 3^AOK pat CRI or Amber I, S%fig5rm TheIV intelral Dnoren andDimmable Field Se0% type LEDfM]uk • tzv lm integral Drrtmr nmmarble or blAr e rp SoldDimC.me wt lzv LdEGDEEC ELv Or mLvnanamrmera • sous capper ens Drees canavurnan (l.-rA LIGHT P19TR19DTIPR CHOICES m sm LCXNOLOGY. poseaulDrou nvnieu sae CREE' uuo anyare Eashour tam wrlasl wm�mnn1ems•umLm any 1. AN 8............................... .N.%TPRP.FP.........IRFPRM.... Gwa�L6MP GIrTE1gwXE 9n vNP •1 a9'tea.„Wr Wro 1 Cal GIES®>Va00.WGXiCON I AUaO anuaGXyidea eL�L U, TYPE auroraTght ICcT9 Palvmsmermahanege anav2e lons me EPLe-saaenaLPL7-so PororM1er wattage and SO, Call see HPL Seslea onpawxP amxa:U." a -) L(LEU) rr a(WH usHLa(INOHES GQDUG.ral ,w—wm,a,..m..a ✓^ate I_]wo,..deasey LPL7-ioa.27-208-Ha J o IN aw0eneaie oeea�iu Ian2,aaX ell pg Dad ry i¢W.I:N e mTMonsiAn its Na pa 2.sNo. UdUd dUNmyk/ [annual fill. mooKamm hew wowsr.>cm N,han UU:w/a.. IWgpwaaW �sw'on n:n e�l� W.eea•N PaawTMmeAee P�e2W gxm.T ala¢uwie. wmmurandUm/ vMearry—am Inl the .Cam— rNl v pxery= rarybcmcpma 7111 ..w LDBAD CA...r.�.. PHONE 977 942 760. 931,.CHO,.�NALm�SALEStIrPROPPIEGHT CON I AURPORLIGHT nawaera l a pL n,Use �,. HYDREL ressand w-2 HE ASPEN LED 12V/120V LED IBOHLIDHTB 1 • Asseddlighnarcwtobleforavarierydmountmg epplicaliona including gund, well, nee, sign and ..chits laED.. 5; • suio4leMwnlcutions • Integral once, for 12N db . Dimmable N lavvola magnetic •• ddhoneo Available nSCRl antlttCRl • t team dial DISSENSIONS LUMEN PACINGES x..N..m..e.ee>.aue.neadyne—1 m-au- a an anI IJ] STANDAPD DISTBIBUTIDN �00 LIGHTING NOTES: 1. ALL LIGHTING SHALL: a. BE EQUIPED WITH AUTOMATIC TIMING DEVICES AND SHALL BE EXTINGUISHED BETWEEN THE HOURS OF 11:00 P.M. AND DAWN. b. BE SHIELDED AND FOCUSED TO ELIMINATE GLARE. GLARE CONTROL SHALL BE ACHIEVED PRIMARILY THROUGH THE USE OF SUCH MEANS AS CUTOFF FIXTURES, SHIELDS AND BAFFLES, AND APPROPRIATE APPLICATION OF MOUNTING HEIGHT, WATTAGE, AIMING ANGLE, FIXTURE PLACEMENT, ETC. c. BE CUTOFF LUMINAIRES, AIMED SO AS NOT TO PROJECT THEIR OUTPUT BEYOND THE OBJECTS INTENDED TO BE ILLUMINATED; OR NON -CUTOFF LUMINAIRES, EQUIPPED WITH GLARE SHIELDS, VISORS, BARN DOORS, AND/OR OTHER SIMILAR SHIELDING ACCESSORIES AS REQUIRED TO MEET THE FOLLOWING CRITERIA: LIGHT DISTRIBUTION FROM ALL LIGHTING INSTALLATIONS SHALL BE CUT-OFF AT ALL ANGLES BEYOND THOSE REQUIRED TO RESTRICT DIRECT ILLUMINATION TO WITHIN THE PERIMETER OF THE LANDSCAPE FEATURE BEING ILLUMINATED. d. NEVER EXCEED 3,000 LUMENS. FURTHER RESTRICTIONS ON LUMENS MAY BE IMPOSED BY THE ARB. e. NOT BE MODIFIED TO REFLECT SEASONAL COLORS. f. BE OF A NUMBER THAT IS COMPATIBLE WITH THE SCALE OF THE OBJECT AND THE DEVELOPMENT TO BE ILLUMINATED, SUCH THAT THE LIGHT EMITTED WILL NOT OVER -ILLUMINATE OR OVERPOWER THE SITE, AS DETERMINED BY THE ARB. 2. EACH OUTDOOR LUMINAIRE EQUIPPED WITH A LAMP THAT EMITS 3,000 OR MORE INITIAL LUMENS SHALL BE A FULL CUTOFF LUMINAIRE AND SHALL BE ARRANGED OR SHIELDED TO REFLECT LIGHT AWAY FROM ADJOINING RESIDENTIAL DISTRICTS AND AWAY FROM ADJACENT ROADS. THE SPILLOVER OF LIGHTING FROM LUMINAIRES ONTO PUBLIC ROADS AND PROPERTY IN RESIDENTIAL OR RURAL AREAS ZONING DISTRICTS SHALL NOT EXCEED ONE HALF FOOT-CANDLE. 3. PHOTOMETRIC MODEL PREDICTS 0.0 fc AT PROPERTY BOUNDARIES. 4. NO TALL POLE MOUNTED LIGHTING IS PROPOSED FOR THIS PROJECT. 'WHYDREL ASPEN LED I' MRrORMANCE DATA wrENOu No- ���IIII�IIIIYE��E�FD a oA MM MMICMAGRAMS ,e_�wwr6,Nnw��aoa,w�a p�,,.aHma..W _�Xw. FIRM INFO: Lineage Architects, P.C. P.O. Box 991 98 Lee Highway Verona, VA 24482 Phone: (540)248-3771 Fax: (540)248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: LTH OF U JONATHAN F. GARBER v No. 038568 ,�01 /10/22*r ti �`'ONAL 'i 1Q W GO F- 0 ON -i all U 4 40 F U Elf Q i M U 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 1 MINOR AMNDMNT 18/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISION/ISSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: SITE LIGHTING PLAN DRAWING NUMBER: C-04 C EL In `oI STR# 7 2' SCH. 40 PVC FORCE MAIN STR# 2 2' SCH. 40 FORCE SCALES: T=3'VER 09+75 10 00 11+00 12-00 13+y10ZT= 570 555 550 555 550 545 540 535 MAINTAIN MINIMUM 24" COVER EXISTING GRADE530525 520 09+75 10+00 11+00 12+00 13+00 13+25 GRAPHIC SCALE 30 0 10 30 60 ( IN FEET ) 1 inch — 30 ft. 565 5 550 545 54c 535 525 570 520 120 FORCE MAIN PROFILE SCALE: 1"=30' FIRM INFO: Lineage Architects, P.C. P.O. Box 991 98 Lee Highway Verona, VA 24482 Phone: (540) 248-3771 Fax: (540)248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL:OFUJONATHAN F. GARBERTNo. 038568 tOl /10/22.$NAL > 7 COMMENTS 1/10/20226 COMMENTS 11/5/2021 5 MINORAMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: SANITARY FORCE MAIN PROFILE DRAWING NUMBER: C-04 D i z 20 2 , li 525 525.65' \ \ \ 0' 52\ EXISTING 1 STORY i � F525.50' HOUSE 1303 SF I n FFE 527.91 i 526.55' I CRITICAL SLOPES T/ / ;; 0 1 / / / /Spp 155000 IVY ROAD US ROUTE 250 80.00' R.O.W. 523 • • I.II ,III /1 , V 1 rn Aj I� . TTM 523 524 \\ ) PROPOSED 1 STORY ADDITION `I, EXISTING 285 SF 30 S FFE 526.60 220 SF FROM PATIO) E: 525.87 (REAARRENTRAMRAN // (SIN2 IS GLE 525.70" ' I RISER) t525.56' +525.40' / 525 525.68' b C "y Y `] - 526 /\ 526 ;'; \ \ CRITICAL SLOPES 'III{ 535 pp / II —d/ II 525.00 FIRM INFO: Lineage Architects, P.C. P.O. Box 991 98 Lee Highway Verona, VA 24482 Phone: (540)248-3771 Fax: (540) 248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: OF, U JONATW F. GARBER a No. 038568 �01 /10/222� ti `�jONAL E� > W z H w 0 � a t~' o O U 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: GRAPHIC SCALE D aD N GRADING/E&SC PLAN GRADING/E&SC PLAN ( IN FEET ) 1 inch = 20 ft. SCALE: 1 "=20' DRAWING NUMBER: C-05 PRECAST CONCRETE OR 4"#57 STONE SECURED w/ GravelPave OR APPROVED EQUIVALENT CUT STONE CURB 4"HEAVY STONE BRICK PAVER 12" RDC, COMPACTED w/ SHEEP'S FOOT ROLLER IN TWO EQUAL LIFTS 3 "' (80 MM) MIN THICKNESS 1" TO 1 2" (25 TO 40 MM) BEDDING SAND 0 GEROTEXTILE 12" (300 MM) WIDE, TURN UP AGAINST CURB COMP ACTED AGGREGATE BASE \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ GEOTEXTILE AS REQUIRED TURN UP AT SIDES OF BASE NOTE:° THIS DETAIL SHALL NOT BE USED FOR EXISTING SOIL COMPACTED TO I a T ACCESSIBLE PARKING SPACES AND 95% STD PROCTOR DENSITY .4° a UTHE AISLE BETWEEN THEM. REMOVE INCOMPETENT SOIL _ O OoO O O oo un W � =IIIII a° Q II III Lc ° HEAVY DUTY GRAVEL DETAIL = 1 ° °a � SCALE: NTS C-06 ° a .. I I I I II I IIIIIIII I IIIIIIII I 5 ° i a COMPACTED SOIL SUBGRADE .■ I no no �I 1150mm (45.27") 575mm (22.63") 575mm (22.63") lele�le�le�l'elf'I��le�l��l�el��le�leel�lleele�leeleel'el�el��� r GREEI�DRIVEWAY GD GRAVEL 60-40 A GREEN ALTERNATIVE FOR PAVING AND LANDSCAPING WEB: greendriveway.com Email: info@greendriveway.com GRAVEL GRID DETAIL SCALE: NTS � COMPACTED AGGREGATE OR COMPACTED BEDDING NOTE: 1. EDGE RESTRAINT SHOULD BE MINIMUM 6 IN. (150 MM) WIDE FOR STREET APPLICATIONS. 2. EDGE RESTRAINT MAY BE EVEN WITH TOP OF BRICK PAVERS. 3. THICKNESS OF AGGREGATE BASE WILL VARY WITH SUBGRADE CONDITIONS AND CLIMATE. COLDER CLIMATES MAY REQUIRE THICKER BASES. PAVER SECTION SCALE: NTS STEEL EDGING GRAVEL DRIVE AND PARKING - APPROX. FLUSH WITH TOP OF EDGING GRADE NO MORE THAN 1/2" BELOW TOP OF EDGING TURF I I II III TAPERED STEEL STAKES TO UUUJJJ INTERIOR OF BED AREA NOTE: 1. STEEL EDGING TO BE 1/8"X4" (.120-.125" AVERAGE THICKNESS) OR EQUIVALENT. STEEL EDGING DETAIL SCALE: NTS STANDARD ALUMINUM SIGN ALUMINUM "VAN -ACCESSIBLE" SIGN 2"X2" STL. TUBE, EXTEND 2'-0" INTO CONC. FILLED PIPE 6" DIA. STD. STL. PIPE FILLED WITH CONCRETE #6 BARS EACH WAY THRU PIPE HANDICAP PARKING SIGN SCALE: NTS 8„ RESERVED PARKING O I PENALTY $100-500 FINE 1 FIRM INFO: Lineage Architects, P.C. P.O. Box 991 98 Lee Highway Verona, VA 24482 Phone: (540)248-3771 Fax: (540)248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: ��LTH Op-%ML U JONATHAN F. GARBER a No. 038568 S01 /10/22�'-'7 ' S&ONAL d W a a > U w a O a x o ti z 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR ANI DMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: CONSTRUCTION DETAILS DRAWING NUMBER: C-06 I 1 1 I I I I I 1 1 I 1 1 1 � I 1 I ' O 'O I 00 N O' 526.55' 1�00 525.65' 526 NY \ i � I ; � I i � I / % I ; yI� ' 7 , 52.5' I 20; 525.90' (ms4010 I 527 � i I I I y I I y HANDICAP SIGN MOUNTED ON POST, 525.8 I DESIGN BY OTHER I 1 1 (ai 1 y n 1 y 525.9 (TOP OF a sl DI 0 KIf)TPQ $00 8 00 5.50' 525.50' (TOP OF WALK) ADA COMPLIANT GRAVEL GRID BRICK PATHWAY If WHEEL STOP, typ. 2 25.78' DESIGN BY OTHER 1. SLOPES IN PARKING SPACES SHALL NOT EXCEED 2%. 2. SLOPE OF WALKWAY SHALL NOT EXCEED 5%. 3. CROSS SLOPE OF WALKWAY SHALL NOT EXCEED 2%. 4. ALL SURFACE MATERIALS SHALL BE ADA COMPLIANT. HANDICAP PARKING LAYOUT SCALE: 1" 5' 0801 DI APPROX. DRAIN AREA =19.30 SO IN APPROX. WEIGHT=5.00 UPS rzx:�1 � l+ 1.25 1 07.85 DIMENSIONS ARE FOR REFERENCE ONLY ACTUAL DIMENSIONS MAY VARY THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH DIMENSIONS ARE IN INCHES NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT GRATE HAD LIGHT DUTY RATING OR POSSESSION OF THIS PUNT DOES NOT CONFER, QUALITY: MATERIALS SHALL CONFORM TOASTM A536 GRADE 705D05 TRANSFER, OR ucSNSE THE USE OF THE DSUOx OR PAINT: CASTINGS ARE FURNISHED WITH A BLACK PAINT TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMARON SIZE OF OPENING MEETS REQUIREMENTS OF AMERICAN DISABILRY CONTAINED HEREIN, OR MANUFACTURE OF ANY ACT AS STATED IN FEDERAL REGISTER PART III, DEPARTMENT OF ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS JUSTICE, 20 CFR PART 36, IS FORBIDDEN, ExCEVT By SPEEDED MITER PERMISSION FROM NYLOPIAST mo,zrvlwas NYLOPLAST 8" DROP —IN GRATE 11SOMEROXAAYE (1 �t rRBUFORO GA GOSH N PHX 70 BGD2W �c FAA i0 9G}G<90 yl� xwxyllI Plee4uecom 526.79' (TOP OF WALK) 9' (TOP OF WALK) 1 c-os 570 �- SEE DRAWING NO.7001-110-275 FOR ADS N-12 & HANCOR DUAL WALL BELL INFORMATION 02 - SEE DRAWING NO.7003-110-031 FOR WATER TIGHT SWAGE JOINT DETAIL 3- DIMENSIONS ARE FOR REFERENCE ONLY ACTUAL DIMENSIONS MAY VARY 4. DIMENSIONS ARE IN INCHES NYLOPLAST 8 x 8 TEE INTERIOR VESTIBULE" THRESHOLD 5' LANDING FFE = 526.83 FFE = 526.79 NOTE: 1. NO HANDRAILS REQUIRED. 2. ACTUAL CROSS SECTION DESIGN BY LANDSCAPE ARCHITECT. 3. MORTAR JOINTS ON AN ACCESSIBLE PATH MAY NOT EXCEED 4" DEPTH. ADA RAMP TO PATIO SECTION SCALE: NTS THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT OR POSSESSION OF THIS PRINT DOES NOT CONFER, TRANSFER, OR LICENSE THE USE OF THE DESIGN OR TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION CONTAINED HEREIN, OR MANUFACTURE OF ANY ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST. 3130 VERONA AVE BUFORD, GA 30518 N o 1 last PHN (770) 932-2443 FAX 770 932-2490 Y www.n to lasbus.com Y P 5.25' RAMP SLOPF — sz FIRM INFO: BRICK P A TI 0 Lineage Architects, P.C. P.O. Box 991 F F E 526.35 98 Lee Highway Verona, VA 24482 Phone: (540) 248-3771 Fax: (540) 248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: I TH OF DML V U JON�. GARBER 9 No. 038568 S01 /10/22� �`SIONAL EON W I� I� 0 W � � U> coo U o � � p `II I --I In v I- 7 1 COMMENTS 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 (ram tiT�] � I � I d�Y K� E9LI lIxS11■ NO. REVISION/ISSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: HANDICAP PARKING LAYOUT & CONSTRUCTION DETAILS DRAWING NUMBER: C-06 A SCALE: NTS SCALE: NTS T 51 g■ INTERNATIONAL SOCIETY OF ARBORICULTURE DO NOT HEAVILY PRUNE THE TREE AT PLANTING. PRUNE ONLY CROSSOVER LIMBS, CO -DOMINANT LEADERS, AND BROKEN OR DEAD BRANCHES. SOME INTERIOR TWIGS AND LATERAL BRANCHES MAY BE PRUNED; HOWEVER, DO NOT REMOVE THE TERMINAL BUDS OF BRANCHES THAT EXTEND TO THE EDGE OF THE CROWN. STAKE TREES ONLY UPON THE APPROVAL OF THE LANDSCAPE ARCHITECT SEE STAKING DETAIL. WRAP TREE TRUNKS ONLY UPON THE APPROVAL OF THE LANDSCAPE ARCHITECT. SEE WRAPPING DETAIL. INTERNATIONAL SOCIETY OF ARBORICULTURE 1400 WEST ANTHONY DRIVE CHAMPAIGN, IL 61821 (217) 355-9411 (217) 355-9516 FAX EACH TREE MUST BE PLANTED SUCH THAT THE TRUNK FLARE IS VISIBLE AT THE TOP OF THE MARK THE NORTH SIDE OF THE TREE IN ROOT BALL. TREES WHERE THE rr THE NURSERY, AND ROTATE TREE TO TRUNK FLARE IS NOT VISIBLE FACE NORTH AT THE SITE WHEN EVER SHALL BE REJECTED. DO NOT POSSIBLE. COVER THE TOP OF THE ROOT BALL WITH SOIL. SET TOP OF ROOT BALL FLUSH TO MULCH RING 1800 MM (6 FT.) GRADE OR 25-50 MM (1-2 IN.) HIGHER IN DIAM. MIN. 2400 MM BFT. DIAM. 100 MM (4 IN.) HIGH EARTH SLOWLY DRAINING SOILS. PREFERRED SAUCER BEYOND EDGE OF ROOT BALL. 200 MM (8 IN.) Ilq YY,,,, •Y I,IIIIIYY,YI/YIIIIIII. "' REMOVE ALL TWINE, ROPE AND ,,,,,,,, 50 MM (2 IN.) MULCH. DO NO PLACE ; ; ; ; , , WIRE, AND BURLAP FROM TOP iii+' + MULCH IN CONTACT WITH TREE TRUNK. HALF OF ROOT BALL MAINTAIN THE MULCH WEED -FREE FOR 'i'?, , +'+'+' 'A P MINIMUM OFTHREE YEARS AFTER PLANT IS SHIPPED WITH A WIRE BASKET AROUND THE 7!15 PLANTING. OT BALL, CUT THE WIRE BASKET IN FOUR PLACES ND FOLD DOWN 200 MM (8 IN.) INTO PLANTING HOLE. NOTE: FOR DIMENSIONS OF PLANTING LACE ROOT BALL ON UNEXCAVATED AREAS, TYPES OF SOIL AMENDMENTS, R TAMPED SOIL.OR SOIL REPLACEMENT, SEE "SOIL IMPROVEMENT DETAILS." MP SOIL AROUND ROOT BALL BASE FIRMLY WITH FOOT PRESSURE SO THAT ROOT BALL DOES NOT SHIFT. NOTES 1. PLEASE REFER TO INTRODUCTION AND USE CRITERIA PRIOR TO USING THIS DETAIL. TREE PLANTING DETAIL - B&B TREES IN ALL SOIL TYPE NOTE: THIS DETAIL ASSUMES THAT THE PLANTING SPACE IS LARGER THAN 2400 MM (8 FT.) SQUARE, OPEN TO THE SKY, AND NOT COVERED BY ANY PAVING OR GRATING. TREE PLANTING DETAIL SCALE: NTS INTERNATIONAL SOCIETY OF ARBORICULTURE INTERNATIONAL SOCIETY OF ARBORICULTURE 1400 WEST ANTHONY DRIVE CHAMPAIGN, IL 61821 (217) 355-9411 (217) 355-9516 FAX INTERNATIONAL SOCIETY OF INTERNATIONAL SOCIETY OF ARBORICULTURE ARBORICULTURE 1400 WEST ANTHONY DRIVE CHAMPAIGN, IL 61821 (217) 355-9411 (217) 355-9516 FAX WIRE OR CABLE SIZES SHALL BE AS FOLLOWS: TREES UP TO 65 MM (2.5 IN.) CALIPER -14 GAUGE TREES 65 MM (2.5 IN.) TO 75 MM (3 IN.) CALIPER -12 GAUGE TIGHTEN WIRE OR CABLE ONLY ENOUGH TO KEEP FROM SLIPPING. ALLOW FOR SOME TRUNK MOVEMENT. PLASTIC HOSE SHALL BE LONG ENOUGH TO ACCOMMODATE 35MM (1.5 IN.) OF GROWTH AND BUFFER ALL BRANCHES FROM THE WIRE. TUCK ANY LOOSE ENDS OF THE WIRE OR CABLE INTO THE WIRE WRAP SO THAT NO SHARP WIRE ENDS ARE EXPOSED 13 MM (0.5 IN.) DIAM. �J PLASTIC HOSE GALVANIZED WIRE OR CABLE TWIST WIRE TO TIGHTEN. 240 x 40 MM (1.5 x 1.5 IN.) E HARDWOOD STAKES OR OTHER APPROVED STAKE MATERIAL _ _ E ALL STAKES SHALL DRIVEN OUTSIDE V THE EDGE OF THE ROOT �f BALL. IMOAL9ASSURE THAT THE BEARING SURFACE OF THE PROTECTIVE COVERING OF THE WIRE OR CABLE AGAINST THE TREE TRUNK IS A MINIMUM OF 12 MM (0.5 IN.). REMOVE ALL STAKING AS SOON AS THE TREE HAS GROWN SUFFICIENT ROOTS TO OVERCOME THE PROBLEM THAT REQUIRED THE TREE TO BE STAKED. STAKES SHALL BE REMOVED NO LATER THE END OF THE FIRST GROWING SEASON AFTER PLANTING. TREES NORMALLY DO NOT NEED TO BE STAKED AND STAKING CAN BE HARMFUL TO THE TREE. STAKING SHOULD BE DONE ONLY WITH THE APPROVAL OF THE LANDSCAPE ARCHITECT IF IT IS EXPECTED THAT THE TREE WILL NOT BE ABLE TO SUPPORT ITSELF. THE FOLLOWING ARE REASONS WHY TREES DO NOT REMAIN STRAIGHT. *TREES WITH POOR - QUALITY ROOT BALLS OR ROOT BALLS THAT HAVE BEEN CRACKED OR DAMAGED. REJECT RATHER THAN STAKE. *TREES THAT HAVE GROWN TOO CLOSE TOGETHER IN THE NURSERY, RESULTING IN WEAK TRUNKS. REJECT RATHER THAN STAKE. *PLANTING PROCEDURES THAT DO NOT ADEQUATELY TAMP SOILS AROUND THE ROOT BALL. CORRECT THE PLANTING PROCEDURE. *ROOT BALLS PLACED ON SOFT SOIL. TAMP SOILS UNDER ROOT BALL PRIOR TO PLANTING. *ROOT BALLS WITH VERY SANDY SOIL OR VERY WET CLAY SOIL. STAKING ADVISABLE. *TREES LOCATED IN A PLACE OF EXTREMELY WINDY CONDITIONS. STAKING ADVISABLE. NOTES 1. PLEASE REFER TO INTRODUCTION AND USE CRITERIA PRIOR TO USING THIS DETAIL. / \ TREE STAKING DETAIL - TREES 75MM (3 IN.) CALIPER OR LESS TREE STAKING DETAIL SCALE: NTS DRIP LINE PROTECTIVE DEVICE MAXIMUM LIMITS OF CLEARING AND GRADING PROPOSED GRADING rrr - a a y a a a / MIN 5' WHERE DRIP LINE IS LESS THAN 5' CONSTRUCTION OPERATIONS RELATIVE TO THE LOCATION OF PROTECTED TREES TREE PROTECTION DETAIL SCALE: NTS FIRM INFO: Lineage Architects, P.C. P.O. Box 991 98 Lee Highway Verona, VA 24482 Phone: (540) 248-3771 Fax: (540) 248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: LTH pF,� v JONATHAN F. GARBER v No. 038568 S01 /10/22ti ti} �SjONAL Y' � 5 w a T Z W a u O dd DRIP LINE v H SNOW FENCE TWO -WALLED PLASTIC SHEETING OR TREE SHELTER MATERIAL APPLIED FROM TRUNK FLARE TO FIRST BRANCH BIO-DEGRADABLE PLASTIC TAPE APPLY THE PLASTIC SHEETING LOOSELY AROUND THE TRUNK TO LEAVE A 12 MM (0.5 IN.) GAP BETWEEN THE TRUNK AND THE SHEETING. OPTION 1 OPTION 2 BREATHABLE FABRIC TREE WRAP APPLIED FROM TRUNK FLARE TO FIRST BRANCH. WRAP PAPER FROM THE BOTTOM UP WITH SUFFICIENT OVERLAP TO COVER ALL BARK. BIO-DEGRADABLE PLASTIC TAPE. TREE WRAP SHOULD BE INSTALLED AT TIME OF PLANTING AND BE REMOVED WHEN DIRECTED BY THE LANDSCAPE ARCHITECT, BUT NO LATER THAN 12 MONTHS AFTER PLANTING. TREES WHOSE NORTH ORIENTATION IS NOT CHANGED FROM THE NURSERY DO NOT NEED TO BE WRAPPED EXCEPT TREES WITH VERY THIN BARK, SUCH AS RED MAPLE, SHOULD BE WRAPPED IF APPROVED BY THE LANDSCAPE ARCHITECT. NOTES 1. PLEASE REFER TO INTRODUCTION AND USE CRITERIA PRIOR TO USING THIS DETAIL. QTREE WRAPPING DETAIL No. 145-002 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISION/ISSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: LANDSCAPING DETAILS DRAWING NUMBER: TREE WRAPPING DETAIL SCALE: I -- TREE FENCING AND ARMORING DETAIL SCALE: NTS C-07