Loading...
HomeMy WebLinkAboutSDP202100073 Review Comments Final Site Plan and Comps. 2022-01-19AL (*�OV +' County of Albemarle COMMUNITY DEVELOPMENT DEPARTMENT $CI1QS Memorandum To: Stephen McCray (stephen.mccray9kimley-horn.com) From: Kevin McCollum — Senior Planner I Division: Planning Services Date: January 19, 2022 Subject: Final Site Plan SDP202100073 WAWA Route 29 and Greenbrier 401 McIntire Road, North Wing Charlottesville, VA 22902-4579 Telephone:434-296-5832 W W W.ALBEMARLE.ORG The Planner for the Planning Services Division of the Albemarle County Department Community Development will recommend approval of the plan referred to above when the following items have been satisfactorily addressed. (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.) [Each comment is preceded by the applicable reference to the Albemarle County Code.] Applicable Comments from Initial Site Plan Action Letter (June 2, 2021) Mariah Gleason If the comment has been addressed, it has been grayed out. Additional comments are added in bold font, like this. [Comment] Project number. Now that the initial site plan has been assigned a project number, please include the number — SDP202100027 — in the title/heading of the Cover Sheet as well as a place holder for the final site plan project number. Add the final site plan project number "SDP202100073" in front of"Final Site Plan For" on the top of the Cover Sheet. Add "Initial Site Plan' in front of the reference to SDP202100027. 2. [32.5.2(b)] Parking schedule. On the Cover Sheet, provide the calculation that was used to determine the number of required parking spaces for this plan. (Note: Per Albemarle County Code, an appropriate scheduled use for this development is "Retail use not otherwise identified" which requires one space per 100 square feet of retail sales area for the first 5,000 square feet and one space per each 200 square feet of retail sales area above 5,000 square feet. Retail sales areas is defined as 80% of the gross floor area.) 3. [32.5.2(n), 4.12.4] Shared parking. The site plan notes that the 20 parking spaces in the small parking area at the rear of the property will be created for the benefit of TMP 61 W-02-2B. Please be aware that, per Sec. 4.12.4(a), County Code does not allow the number of proposed parking spaces to exceed the number of required spaces by more than 20 percent. The current site plan exceeds the number of required spaces by 41.7°/u. It may be possible to provide the desired parking schedule through a shared parking agreement. Staff recommends following up with the Zoning Division to see if this may be an option. a. [4.12] This comment has not been addressed. Please provide additional evidence to be reviewed by the Zoning Administrator stating the need for this overflow parking area. Provide shared parking agreements between all applicable parties. Provide safe and convenient access via sidewalk or other means of access to and from the parcel who will be sharing this parking. Include a label that references applicable shared parking agreement and include which tax map and parcel number enjoys the use of these parking spaces on Sheet CS-101. Comment stands. Please provide a shared parkin¢ a¢reement for Zoning review. Applicant has acknowledged a shared narking agreement will he provided prior to plan approval. 4. [32.5.2(n), 4.171 Outdoor lighting. Please refer to comments provided by the ARB reviewer below (comments #6-12, specifically) concerning outdoor lighting. 5. [Comment] Landscaping. Please refer to comments provided by City of Charlottesville Department of Public Utilities and ARB, below, regarding landscaping and plantings. 6. [Comment] Grading. Please refer to comments provided by City of Charlottesville Department of Public Utilities regarding proposed grading over existing gas lines. [4.12.18] Loading zone. A loading space is not required for this development, per 4.12.13, since the building is less than 8,OOOsf. However, a loading zone is shown on the site plan. County Code Sec. 4.12.18 requires loading spaces to be a minimum of 12 feet in width, 14% feet in clearance height and a length sufficient to accommodate the largest delivery trucks serving the establishment, but providing no less than 25 feet in length. Please be aware, that code section also requires the loading space to be designed in such a way that no part of any vehicle will extend into a driveway or aisle space. Please revise the loading zone shown on the site plan to align with these ordinance requirements. 8. [32.5.2(n)] Fuel stations and pumps. On the Cover Sheet, please edit the "WAWA Information" notes to clearly state the number of fuel stations and pumps being proposed by this project. 9. [32.5.2(q)] Traffic generation. Provide expected traffic generation information, if not provided already. 10. [32.5.2(i), 32.5.2(m)] Vehicular travelways. In addition to the comments provided by Engineering and VDOT reviewers, below, please also show the distance to the centerline of the nearest existing street intersection from the proposed ingress and egress points. 11. [4.12.19] Dumpster pad. The regulations for dumpster pads require the concrete pad to extend at least eight feet beyond the front of the dumpster. Please revise the plan to demonstrate that this minimum design requirement is being met. This could be done with a distance label on the site plan. 12. [32.5.2(n)] Monument signs. Remove all depictions and notes regarding monument signs. Those signs are reviewed through a separate application and permitting process. 13. [32.5.2(a)] Zoning. Include in the zoning notes that this property is subject to special use permit SP1991-00069 and its conditions. State the conditions of approval in the notes. See reference document attached. 14. [32.5.2(a)] Setbacks. Revise the setback notes to reflect the following: a. Front: loft minimum; no maximum b. Side and Rear: none 15. [32.5.2(1)] Water supply watershed. In the Site Statistics notes on the Cover Sheet, provide a note to indicate whether the site is located within a water supply watershed. 16. [32.5.1(c)] Boundary line. If not given already, please provide the curve data for the curved boundary line at the northernmost property comer. 17. [32.7.9.4(c)] Existing landscape features. On the Existing Conditions sheet, identify whether exiting tree/vegetated areas are composed of evergreen, deciduous, or a mix of tree types. Also please provide a label for the existing tree line symbology. 18. [32.5.2(n)] Building footprint. Provide length and width dimensions for the proposed building footprint. 19. [32.5.2(a)] Scales. With the scales on each plan map sheet, please include a "I in = " label. 20. [32.5.2(a)] Abutting parcel information. Provide the present uses for all parcels that abut the subject property. 21. [32.5.2(i)] Easement plat. Please be aware, prior to approval of a final site plan for this development, an easement plat for new, required easements will need to be submitted, approved, and recorded. Comment stands. Final Site Plan Review Comments 1. [32.6.21 Please remove the SWMIE&S Sheets from this Site Plan. See Engineering comments for more information. Revise the sheet index and total number of sheets count on the cover sheet accordingly. 2. [General Comment] Please add a date of revision. 3. [32.6.2(k) and 4.171 Lighting. Please revise the Lighting Plan to incorporate a LLF of 1.0. The spillover of lighting from luminaires onto public roads shall not exceed one-half foot candle. ARB may provide additional lighting comments that need to be addressed prior to final site plan approval. 4. [32.7.9.5(d)] The Zoning Ordinance provides that one large street tree is required for every 50 feet of street frontage or one medium street tree for every 40 feet of street frontage along Greenbrier Drive and Seminole Trail. a. Unless required by ARB, the requirements for the amount of street trees along Greenbrier Drive are much less than the suggested 7 street trees. The linear frontage is only the distance the property abuts Greenbrier. The full 352 If of the property is partially buffered by TMP 61W-02-2B. b. Unless required by the ARB, correct the calculations provided on the Planting Plan (Sheet CP-101) for Seminole Trail to correctly say one large tree per 501f instead of one per 351f. 5. [32.7.9.4(a)] It appears "Quercuz x warei (QW)" is not a tree listed on the Albemarle County Approved Plant List. a. Please provide landscaping that is reflected on the Albemarle County Recommended Plant List which can be found here. 6. [General Comment] A special exception (SE) request to vary the minimum design requirements and improvements for vehicle access aisles as outlined in Section 4.12.17 of the Zoning Ordinance has been received. The Applicant is requesting a waiver to increase the grade of the access aisle to Greenbrier Dr. from the permitted maximum of 10% up to a maximum of 16%. This SE (SE202100048) is currently under review. A Board of Supervisors date has been secured for Wednesday, February 161. Comment stands. This special exception will need to be approved by the Board of Supervisors prior to Final Site Plan approval. Please contact Kevin McCollum at the Department of Community Development at kmccollum&albemarle.org or (434) 296-5832 ext. 3141 for further information. Additional Reviewer Comments Albemarle County Engineering Services — Emily Cox, ecox2@albemarle.org — Requested Changes (1/18/2022). 1. The VSMP plan WPO202100049 must be approved before this final site plan can be approved. Rev. 1: Comment not addressed. Rev. 2: Comment not addressed. 2. An easement plat must be submitted and recorded before the final site plan can be approved. The easement plat will need SWM and drainage deeds which the County will provide when that plat is ready for recordation. Rev. 1: Comment not addressed. 3. [CA-100] This plan is SDP202100073. Please revise and remove the old initial site plan number. Rev. 1: Comment addressed. 4. Please remove sheets that apply to VSMP plan such as E&S and SWM. They will not be reviewed with this plan. The required contents of a final site plan can be found here: hops://library.municode.com/va/albemarle county/codes/code of ordinances?nodeld=CH18Z0_ ARTIVPR S32SIPL 532.6FISIPLFOCO S32.6.2COFISIPL Rev. 1: Comment addressed. 5. [CG-101] Maximum slope allowed is 2:1. Grading appears to exceed this in a few places. Rev. 1: Comment not addressed. Contours are still measuring steeper than 2:1 slopes. Revise the grading or provide spot shots and label the distance between the spots to show the max grade is 2:1 over the slope. For example, this is 5ft of vertical change in less than 10 ft of N �+� horizontal chang Rev. 2: Comment addressed. 6. [CG-101] Please check 2:1 and 3:1 labels. Slope appears to be steeper than 3:1 where it is labeled F� as 3:1. Rev. 1: Comment not addressed. For example, this should measure 15 R to be 3:1: h� Rev. 2: Comment addressed. t nsure landscaping that can withstand steep slopes is specified for the slopes steeper than 3:].Rev. 1: Please show ground cover or steep slope grass seed in this area: ---'% Rev. 2: Comment addressed. Ensure all proposed easements are shown. This includes a SWM facility easement around the SWM facility. This is separate from the public drainage easement around the outfall from the facility. Rev. 1: The SWM facility easement seems inadequate to perform maintenance or replace the SWM facility. Ensure there is room for equipment within the easement. See the design standards manual, page 15 for guidance: https://www.albemarle.ora/Home/ShowDocument?id=270 Rev. 2: Comment addressed. 9. Do you have permission to grade off site? It appears you are doing work on parcel 061 WO-02-00- 002130. Rev. 1: Comment not addressed. Rev. 2: Comment not addressed. 10. Per county code 18-4.12.17.a, vehicle access aisles that are not adjacent to parking spaces, shall not exceed a grade of ten percent. The entrance off Greenbrier Dr. appears to exceed 10%. Rev. 1: Comment not addressed. Special exception (SE202100048) is under review. Rev. 2: Comment not addressed. Special exception (SE202100048) is under review. 11. Parking areas should not exceed 5% grade anywhere, in any direction. Rev. 1: Comment addressed. 12. Please show DEQ approval of remedial activities for the leaking underground storage tank and show any necessary notes on the plan for the contractor. Rev. 1: Comment not addressed. Rev. 2: Comment addressed. 13. Minimum slope of storm pipes is 0.5%. Please revise the 0.10% slope. Rev. 1: Comment addressed. 14. Please show storm pipe calculations including velocity and hydraulic grade lines. Rev. 1: Velocity should not exceed 15 ft/s. Per VDOT drainage manual 9.4.8.7, 10 ft/s max is preferred. Rev. 2: Comment addressed. 15. All proposed trees should be at least 5' from storm pipes and structures. Rev. 1: Comment addressed. 16. Structure 100 should not be in the middle of a travelway. Also the SWM facility should be located so it doesn't impede the Greenbrier entrance if maintenance or replacement is necessary. Rev. 1: Please show that structure 100 is at least outside of the wheel path of the travelway. Rev. 2: Comment addressed. Albemarle County Building Inspections — Betty Slough, bslougih@albemarle.org—No objection (12/14/2021). Albemarle County Fire -Rescue — Howard Lagomarsino, hlaeomarsino@albemarle.org — No Objection (10/9/2021). Virginia Department of Transportation (VDOT)—Adam Moore, Adam.Moore@vdot.vir iginia.gov—No objection (9/30/2021). Albemarle County Service Authority (ACSA) — Richard Nelson, melson@serviceauthority.org — Most recent submittal was sent to ACSA for review on 12/29/2021. That review is currently pending. Comments will be forwarded to the Applicant upon receipt. Albemarle County E911—Elise Kiewra, ekiewra@albemarle.org—No Objection (10/6/2021). Albemarle County Architectural Review Board — Margaret Maliszewski, mmaliszewski@albemarle.org — Approved (1/14/2022). Virginia Department of Health — Alan Mazurowski, alan.mazurowskikvdh.vir iginia.gov — No objection (10/29/2021).