Loading...
HomeMy WebLinkAboutSUB199300105 Checklist 1993-08-20 SUBDIVISION PLAT .,LIECKLIST: PRELIMINARY PUN FINAL APPROVAL NAME OF PROJECT: '.,�eF1 `T 13 E:e Z& ► ITEMS REQUIRED TECHNICAL ITEMS REQUIRED ON PRELIMINARY AT DEADLINE FOR SUBMITTAL: AND FINAL PLATS: ❑ Preliminary conference with staff GENERAL CONTENT ❑ Application and fee IX Title of subdivision(18.52a) ❑ Fourteen(14)copies preliminary(or final)plat g Names/addresses of record owner, subdivider and any ❑ Two (2) copies preliminary (or final) road and drainage easement holders(18-52a) plans i• Name of surveyor,date of drawing,number of sheets,north ❑ Two(2) copies building site studies-identify 25%slopes, point,scale(1"=100') (18-52a) note location,area and dimensions of building site on each Vicinity map(1"=2,000') (18-52b) lot Topo with 5' contours, boundary lines, floodplain limits ❑ Two(2) copies traffic analysis plan if required by Virginia (18-52c) Department of Transportation 1. Location,width and names of streets,easements,right-of- way(18-52d) Kim ITEMS REQUIRED ONE WEEK PRIOR TO "---, El_Lot lines,total acreage in each use(18-52d)LM4 ?la . PLANNING COMMISSION MEETING DATE: Et,Location and dimensions of proposed streets,lots,building ❑ HEALTH DEPARTMENT written approval setback lines,easements(18-52e) ❑ SOIL SCIENTIST report if required[for five (5) lots or [a• Boundary survey(18-52e) more if runoff control for ten (10) lots or more if other n Land to be dedicated or reserved for public use or common ' private use(18-52f) yc...,n,1‹• areas] Comprehensive Plan proposals for subject property (18- 0 SERVICE AUTHORITY written preliminary approval if 2g, 18-17) public water or sewer HAreliminary plans for bridges or culverts(18-52h) ❑ COUNTY ENGINEER written preliminary approval: �/�Fract boundaries if multiple sources of title(18-52i) ❑ Runoff Control aExisting zoning and proposed uses (compliance with ❑ Stormwater Detention(18-22) zoning) (18-52j) ❑ Private road plans/profile . Number,approximate dimensions and area of lots(18-521) ❑ Public road plans p. Building site on each lot- location area and dimensions ❑ Drainage plans (18-52o) ❑ Existing private road-review of adequacy for total alpAevelopment rights assigned including aggregate acreage number of lots to be served (RA zone) (18-52p) ❑ FIRE OFFICER written preliminary approval(18-26): 18. Deed book reference of instrument whereby subject parcel ❑ Hydrant locations(if public water reasonably avail- was created(18-52q) able) "'> 0 Tax Map,parcel number(18-52r) ❑ Fire Flow adequate CR/mRunoff control ordinance:100'septic setback from streams ❑ Dumpster location and screening RAcenic highway setbacks ❑ Provisions for handicapped access B. Magisterial District noted ❑ VIRGINIA DEPARTMENT OF TRANSPORTATION Date received stamp(by staff) preliminary approval: Additional setback reserved in keeping with Comprehen- ❑ Public road plans/profiles sive Plan(18-8) ❑ Entrance location and site distance Dedication of minimum 50' right-of-way or greater if re- 0 Entrance 500'from crossover(18-37o) quired(18-8) ❑ Shared entrance recommended Dedication of 1/2 the right-of-way(18-30) ❑ PLANNING STAFF APPROVAL ' Adequate utility and drainage easements(18-12,16) -'P Lot sizes, number of lots, building setbacks apg frontage ❑ Condominium checklist needed conform to Zoning Ordinance(18-28,29,30) �'� ❑ Written waiver request atisfactory lot arrangement, design and shape. No odd- 0 Technical items shaped elongations to provide area or frontage(18-29) UCorner lot-maintain building line on both streets(18-31) V e t sizes adequate for utilities available(18-23c) ❑ Temporary cul-de-sacs: required if street exceeds 300'or P Public water or sewer provided if reasonably available serves more than four residences (18-25) ❑ A• lleys: 20'right-of-way if required for parking or service Side lot lines perpendicular to street(18-32) ❑ Reserved or spite strips not permitted Remnants or out lots added to adjacent lots(18-33) ❑ Service drives: reserved adjacent to a major highway Double frontage lots require waiver(18-34) PUBLIC STREETS (18-39): g Good orientation if adjoining major highway(18-35) ❑ Virginia Department of Transportation construction PRIVATE ROADS: standards ❑ Demonstration of significant degradation;or 0 Street names-shall not duplicate existing streets in City or ❑ T• wo lots only;or County unless a continuation of existing street ❑ Non-residential or non-agricultural;or ❑ Street signs-required at intersection ❑ Not in rural area and residential other than single-family ❑ Sidewalks and curb and gutter if required detached;or 0 Existing public road improved to accommodate proposed ❑ Family Division traffic ❑ Written waiver request under: ❑ Section 18-36c-Private road would benefit environment or ADDITIONAL TECHNICAL ITEMS REQUIRED- public interest FINAL PLATS: ❑ Section 18-36f-Request access to public street ❑ Section 18-36g-Existing easement to fixed width GENERAL CONTENT ❑ O• riginal maximum size 11"x 18" (18-55) ❑ Notarized owner's approval statement and signature (18- Road is adequate to carry expected traffic volume;including: 55b) ❑ Width of easement ❑ Signature panels for Chairman,Planning Commission and ❑ Width of travelway Agent,Board of Supervisors(18-55k) ❑ Based/surface treatment 0 Linear-angular dimensions and curve data(18-55d) ❑ Sight distance ❑ Lot numbers and block identification(18-55e) ❑ C• omprehensive Plan show no public road planned 0 Lot size in square feet indicated on each parcel(18-550 ❑ Fee of road is owned by adjacent owners or homeowners 0 L• ocation and material of permanent reference monuments association (18-55g) ❑ No through traffic;no more than one intersection with state ❑ Bearing and distance tie(18-55h) highway ❑ Restrictions imposed by Board of Supervisors(18-55j) NOTES ON PLAT: ❑ Note regarding temporary cul-de-sac(18-551) ❑ N• o further subdivision without Planning Commission ap- ITEMS REQUIRED PRIOR TO SIGNING PLAT proval (FINAL APPROVAL): ❑ Only one dwelling per lot ❑ All lots enter onto private road ❑ PLANNING STAFF final approval ❑ Street name sign ❑ SERVICE AUTHORITY final approval ❑ Private maintenance sign,if required 0 COUNTY ENGINEER final approval GENERAL ROAD DESIGN(18-37): ❑ FIRE OFFICER final approval ❑ VIRGINIA DEPARTMENT OF TRANSPORTATION ❑ Alignment:continuation of existing streets final approval ❑ Layout:discourage through traffic in residential areas but 0 COUNTY ATTORNEY approval of homeowners'docu- avoid jogs ments(18-7) ❑ Angle:80°or greater at intersections 0 Bond posted for all public improvements(18-19) 0 Access:to adjoining parcels for orderly development ❑ Soil Erosion and Sedimentation permit(18-24) ❑ Grade:8%maximum or 10%with special circumstances; paved ditches on 5%grades ❑ Runoff Control permit ❑ Right-of-way width:minimum 50'right-of-way radius;min- imum 40'paved radius.Length to be determined by Plan- ning Commission.