HomeMy WebLinkAboutSDP202200005 Plan - Submittal (First) 2022-01-201 - -
I
1 C,H ONL7) ®AL'�) _ STATE ROUTE 250
S II E PLAN
SCALE: " = 20'-0"
N3311
CURVE TABLE
CURVE
I RADIUS I
ARc LENGTH
I TANGENT
I CHORD LENGTH I
cHORD BEARING
DELTA ANGLE
cl
202.00'
35.43'
1 I-1.-16'
1 35.39' 1
5 64°I4'20" W
10°03'02"
c2
1 198.00' 1
53.51'
I 26.92'
1 55.54' 1
5 61"31'21" W
15°29'00"
N3� °05'Og „W
g.�4,
IIIIIIIII E• •
4%^'rYm ...
+
VICINITY MAP
VIQ,o•�NITY MAP NORTH+
NOT TO SCALE
SHEETINDEX
ARCHITECTURAL
A-1
PROJECT DATA E SITE PLAN
A-2
ENLARGED CANOPY PLAN
A-3
ELEVATIONS
A-4
MATERIAL BOARD
ELECTRICAL
E51.0
PHOTOMETRIC PLANS
GOVERNING CODES
BUILDING:
2015 VIRGINIA BUILDING CODE
MECHANICAL:
2015 VIRGINIA MECHANICAL CODE
PLUMBING:
2015 VIR61NIA PLUMBING CODE
ENERGY:
2015 VIR6INIA ENERGY CONSERVATION CODE
ELECTRICAL:
2014 EDITION NATIONAL ELECTRICAL CODE
FUEL / GAS:
2015 VIRGINIA FUEL GAS CODE
FIRE:
2015 INTERNATIONAL FIRE CODE
AC-CE551BLE:
2009 EDITION OF AN51 A111.I
LEGAL DESCRIPTION
LOT 1-5, TAX MAP -78, PARCEL 55AZ, 18.51 ACRES (8Op53 S.F)
SITE PLAN KEYED NOTES
I. DASHED LINE INDICATING OUTLINE OF OVERHEAD MEAL DELIVERY
CANOPY.
2. DASHED LINE INDICATING OUTLINE OF OVERHEAD FACE TO FACE
CANOPY.
3. EXISTING VEHICLE DRIVE AI5LE TO REMAIN.
4. EXISTING PARKING FIELD TO REMAIN, NO CHANCE.
5. EXISTING ORDER POINT MENU BOARD TO REMAIN. NO CHANCE.
6. EXISTING CONCRETE WALKWAY TO REMAIN.
'I. EXISTING CONCRETE CURB TO REMAIN, VERIFY EXISTING
CONDITION OF CURB, REPLACE ANY DAMAGE OR BROKEN CURB
TO LIKE NEW CONDITION.
8. EXISTING CONCRETE ADA COMPLIANT ACCESSIBLE CURB. RAMP /
MARKED PATHWAY TO REMAIN.
9. EXISTING LANDSCAPING AREA TO REMAIN.
10. LOCATION OF ELECTRICAL AND/OR GAS CONNECTION. CONFIRM
UNDERGROUND UTILITIES PRIOR TO START OF CONSTRUCTION.
II. EXISTING CATCH BASIN GRATE TO REMAIN. VERIFY EXACT
LOCATION PRIOR TO START OF CONSTRUCTION.
12. EXISTING GREASE INTERCEPTOR TO REMAIN. VERIFY EXACT
LOCATION PRIOR TO START OF CONSTRUCTION.
15. OUTSIDE FACE OF EXIST. BUILDING EXTERIOR HALL.
14. EXIST. PROPERTY LINE.
15. EXIST. BUILDING SETBACK LINE.
16. EXISTING TRASH ENCLOSURE TO REMAIN.
IT. EXISTING CANOPY STRUCTURES TO REMAIN. DO NOT DISTURB.
15. EXISTING UNDERGROUND STORM HATER PIPING INDICATED BY
DASHED LINE. G.G. TO VERIFY EXALT LOCATION PRIOR TO
COMMENCING CONSTRUCTION.
PROJECT DATA
I. PROJECT NAME: GHIGK-FIL-A, #5161
2. PROJECT ADDRESS: 1626 RICHMOND RD
CHARLOTTE5VILLE, VA 229I1
3. PROJECT WORKSGOPE: INSTALLATION OF STEEL FRAMED FACE TO FACE
AND MEAL DELIVERY CANOPY (EMPLOYEE SHADE
STRUCTURES) WITH MINOR ELECT. / PLUMB. WORK.
4. PARCEL NO: 0-1800-00-00-055A2
5. ZONING: HC- HI6HHAY COMMERCIAL
6. PROPERTY AREA: 60,055 S.F. (1.&4 ACRES)
7. FIRE SPRINKLERS: YES A.F.E.S. (EXISTING BUILDING)
8. TYPE OF CONSTRUCTION:
o.
EXISTING BUILDING:
b.
NEW MEAL DELIVERY CANOPY
c.
NEW FACE TO FACE CANOPY
9. OCCUPANCY:
o.
EXISTING BUILDING:
b.
NEW MEAL DELIVERY CANOPY
c.
NEW FACE TO FACE CANOPY
10. BUILDING
AREA:
o.
EXISTING BUILDING:
b.
NEW MEAL DELIVERY CANOPY
c.
NEW FACE TO FACE CANOPY
VB (EXIST. UN-CHAN6ED)
115
IIB
A-2 (EXIST. UNCHANGED)
A-2
U (ACCESSORY USE TO A-2)
50. FT. OCCUPANCY
4,835 S.F. A-2 (EXI5TIN6)
424 S.F. A-2
880 S.F. U (ACCESSORY USE)
d. TOTAL AREA: 6,13'1 S.F.
11. ALLOWABLE AREA: PER VBC TABLE 506.2
o. FIRE SPRINKLERED BUILDING: 24,000 S.F. (EXIST. I -STORY BLDG)
*b. ACTUAL BUILDING AREA: 6,139 S.F.
* NOTE: INCLUDED NEN CANOPIES IN TOTAL AREA IN CALCULATIONS
12. AREA OF CONSTRUCTION: 1,504 5.F
15. CANOPY HE16HT:
o. MEAL DELIVERY CANOPY: 9'-b" BOTT. OF CANOPY
b. FACE TO FACE CANOPY W-b" SOTT. OF CANOPY
14. BUILDIN6 SETBACKS
o. NORTH PROP LINE: 20'-0"
b. WEST PROP LINE: 30`-0" (RICHMOND STATE RD)
c. SOUTH PROP LINE: 20'-0"
d. EAST PROP LINE: 20'-0" (LUXOR RDJ
15. PARKING REQUIREMENTS:
EXISTING TO REMAIN NO CHANCE TO PARKING SPACES OR EXISTING DRIVE
THRU LANES.
PROJECT DIRECTORY
OWNER:
CHICK-FIL-A, INC.
5200 BUFFINGTON ROAD
ATLANTA, GA 50549
TROY TRIPP, DIRECTOR OF CONST,
trog.tripp®cFacorp.com
(404) 305-4613
PROJECT MANAGER:
BUREAU VERITAS,LLC
IT200 N PERIMETER DRIVE
SUITE 2-5
SCOTTSDALE, ARIZONA 85255
MICHAEL ANDERSON, GPM
(480) Tr-1800
STRUCTURAL:
FASHION INC.
JASON HOLMES
1019 E. NORTH STREET
OTTANA, K5 66061
PH: (185) 242-&111
ARCHITECT:
E5ENCIA LLC
I"143 E. McNAIR DRIVE
SUITE 200
TEMPS, AZ. 85283
JEFFREY HINTER, R.A.
wintermesencia.org
(480)-m-0959 EXT 120
MEGH. /PLUMB
INTERPLAN LLC
604 COURTLAND STREET
SUITE 100
ORLANDO,FL. 328O4
BARB MARTIN
Bmart in®interp I an I I c.com
(401) 645-5008
MUNICIPALITY:
ALBEMARLE COUNTY
401 MGINTIRE ROAD
CHARLOTTESVILLE, VA 2-MO2
MIKE DELLINGER
mdel linger®a Ibemorle.org
(434) 296-5832 x4504
GENERAL NOTES
A. PRIOR TO COMMENCEMENT OF CONSTRUCTION THE 6.0. SHALL BE
RESPONSIBLE TO VERIFY AND LOCATE EXACT LOCATION/DEPTH
OF UNDERGROUND UTILITY LINES, COMMUNICATION LINES, ETC.
SERVING THIS SITE. IDENTIFY UTILITIES AS TO SCOPE OF WORK
AND LOCATION OF DIGGING.
B. HHERE REQUIRED. G.C. SHALL NOTIFY ADJACENT TENANTS /
PROPERTY OHNER5 OF ANY SERVICE INTERRUPTIONS AT LEAST
48 HOURS PRIOR TO SERVICE INTERRUPTIONS.
C. ANY DAMAGES TO UNDERGROUND UTILITY LINES SHALL BE
REPORTED TO THE UTILITY COMPANY INVOLVED. O.C. SHALL
REPAIR DAMAGES PER UTILITY CO. REQUIREMENTS AT
CONTRACTORS EXPENSE.
D. UPON INSTALLATION OF FOOTINGS, IT SHALL BE THE 6.0
RESPONSIBILITY TO OBTAIN THE SERVICES OF A LAND
SURVEYOR TO PROVIDE TOP OF ASPHALT/GONG. DIVE TOPO
POINTS TO THE CANOPY FABRICATOR PRIOR TO CANOPY
FABRICATION. SAID LAND SURVEYOR SHALL PROVIDE A
DRAHIN6 DEPICTING TOPO POINTS, NO EXCEPTIONS TAKEN.
SWPP GENERAL NOTE
NOTE TO CITY / COUNTY ENGINEERING DEPT. THE CONSTRUCTION
OF THE THI5 PROJECT DOES NOT REQUIRE ANY GUT / FILL OR
6RADIN6. ALL FOOTINGS REGARDLESS OF TYPE ARE
EXCAVATED ON THE FIRST DAY OF CONSTRUCTION, EXCESS DIRT
HAULED OFF IMMEDIATELY AND DISPOSED OF PER CITY / COUNTY
REQUIREMENTS. ALL TRENCHING 15 DUG, ELECTRICAL AND OR GAS
LINES INSTALLED, TRENCH 15 BACKFILLED ON THE SAME DAY. NO
GRADING ELEVATION5 CHANCES OCCUR NOR DISTURBANCE OF
ANY HATER DRAINAGE PATTERNS. PERVIOUS OR NON-PEREVIOU5
AREAS ARE NOT AFFECTED. THEREFORE A STORM HATER
PREVENTION PLAN 15 NOT REQUIRED FOR THI5 PROJECT.
5200 BUFFINGTON ROAD.
ATLANTA, GEORGIA 30349
(404) 765 - 8000
THESE PLANS AND SPECIFICATIONS, AS WELL AS
CHICK-FIL-A, INC. NAME AND LOGO, TRADEMARKS AND
DESIGNS ARE THE EXCLUSIVE PROPERTY OF
CHICK-FIL-A CORPORATION. ANY REPRODUCTION,
MODIFICATION, DISCLOSURE AND/OR USE OF
THESE MATERIALS (OR ANY PORTION OF THEM)
WITHOUT CHICK-FIL-A'S PRIOR WRITTEN CONSENT
IS STRICTLY PROHIBITED.
esencia
1743 E. McNair Drive, Suite 200
Tempe, Arizona 85283
Telephone 480-755-0959
O�Qi�'Tli OF
UC� iro
JEFFREY W. WDrM
Lic. No. 0I5908
I�RCHI*T
V
08-02-2021
Revision Schedule
Rev
Date
By
Description
r
r
N
�
N
Q
00 IC)
Q
V
Q
M�
J
J_
0-
0
Z
LL
O
O
w
W
Q
o
U
m
U
N
2
a�
o
a
Issue Date:
08-02-2021
Drawn By:
TP/GA
Job Number:
19060
Sheet Title:
Pro'ect Data
09ite Plan
Scale: As indicated
Sheet Number:
A-1