Loading...
HomeMy WebLinkAboutSDP202200005 Plan - Submittal (First) 2022-01-201 - - I 1 C,H ONL7) ®AL'�) _ STATE ROUTE 250 S II E PLAN SCALE: " = 20'-0" N3311 CURVE TABLE CURVE I RADIUS I ARc LENGTH I TANGENT I CHORD LENGTH I cHORD BEARING DELTA ANGLE cl 202.00' 35.43' 1 I-1.-16' 1 35.39' 1 5 64°I4'20" W 10°03'02" c2 1 198.00' 1 53.51' I 26.92' 1 55.54' 1 5 61"31'21" W 15°29'00" N3� °05'Og „W g.�4, IIIIIIIII E• • 4%^'rYm ... + VICINITY MAP VIQ,o•�NITY MAP NORTH+ NOT TO SCALE SHEETINDEX ARCHITECTURAL A-1 PROJECT DATA E SITE PLAN A-2 ENLARGED CANOPY PLAN A-3 ELEVATIONS A-4 MATERIAL BOARD ELECTRICAL E51.0 PHOTOMETRIC PLANS GOVERNING CODES BUILDING: 2015 VIRGINIA BUILDING CODE MECHANICAL: 2015 VIRGINIA MECHANICAL CODE PLUMBING: 2015 VIR61NIA PLUMBING CODE ENERGY: 2015 VIR6INIA ENERGY CONSERVATION CODE ELECTRICAL: 2014 EDITION NATIONAL ELECTRICAL CODE FUEL / GAS: 2015 VIRGINIA FUEL GAS CODE FIRE: 2015 INTERNATIONAL FIRE CODE AC-CE551BLE: 2009 EDITION OF AN51 A111.I LEGAL DESCRIPTION LOT 1-5, TAX MAP -78, PARCEL 55AZ, 18.51 ACRES (8Op53 S.F) SITE PLAN KEYED NOTES I. DASHED LINE INDICATING OUTLINE OF OVERHEAD MEAL DELIVERY CANOPY. 2. DASHED LINE INDICATING OUTLINE OF OVERHEAD FACE TO FACE CANOPY. 3. EXISTING VEHICLE DRIVE AI5LE TO REMAIN. 4. EXISTING PARKING FIELD TO REMAIN, NO CHANCE. 5. EXISTING ORDER POINT MENU BOARD TO REMAIN. NO CHANCE. 6. EXISTING CONCRETE WALKWAY TO REMAIN. 'I. EXISTING CONCRETE CURB TO REMAIN, VERIFY EXISTING CONDITION OF CURB, REPLACE ANY DAMAGE OR BROKEN CURB TO LIKE NEW CONDITION. 8. EXISTING CONCRETE ADA COMPLIANT ACCESSIBLE CURB. RAMP / MARKED PATHWAY TO REMAIN. 9. EXISTING LANDSCAPING AREA TO REMAIN. 10. LOCATION OF ELECTRICAL AND/OR GAS CONNECTION. CONFIRM UNDERGROUND UTILITIES PRIOR TO START OF CONSTRUCTION. II. EXISTING CATCH BASIN GRATE TO REMAIN. VERIFY EXACT LOCATION PRIOR TO START OF CONSTRUCTION. 12. EXISTING GREASE INTERCEPTOR TO REMAIN. VERIFY EXACT LOCATION PRIOR TO START OF CONSTRUCTION. 15. OUTSIDE FACE OF EXIST. BUILDING EXTERIOR HALL. 14. EXIST. PROPERTY LINE. 15. EXIST. BUILDING SETBACK LINE. 16. EXISTING TRASH ENCLOSURE TO REMAIN. IT. EXISTING CANOPY STRUCTURES TO REMAIN. DO NOT DISTURB. 15. EXISTING UNDERGROUND STORM HATER PIPING INDICATED BY DASHED LINE. G.G. TO VERIFY EXALT LOCATION PRIOR TO COMMENCING CONSTRUCTION. PROJECT DATA I. PROJECT NAME: GHIGK-FIL-A, #5161 2. PROJECT ADDRESS: 1626 RICHMOND RD CHARLOTTE5VILLE, VA 229I1 3. PROJECT WORKSGOPE: INSTALLATION OF STEEL FRAMED FACE TO FACE AND MEAL DELIVERY CANOPY (EMPLOYEE SHADE STRUCTURES) WITH MINOR ELECT. / PLUMB. WORK. 4. PARCEL NO: 0-1800-00-00-055A2 5. ZONING: HC- HI6HHAY COMMERCIAL 6. PROPERTY AREA: 60,055 S.F. (1.&4 ACRES) 7. FIRE SPRINKLERS: YES A.F.E.S. (EXISTING BUILDING) 8. TYPE OF CONSTRUCTION: o. EXISTING BUILDING: b. NEW MEAL DELIVERY CANOPY c. NEW FACE TO FACE CANOPY 9. OCCUPANCY: o. EXISTING BUILDING: b. NEW MEAL DELIVERY CANOPY c. NEW FACE TO FACE CANOPY 10. BUILDING AREA: o. EXISTING BUILDING: b. NEW MEAL DELIVERY CANOPY c. NEW FACE TO FACE CANOPY VB (EXIST. UN-CHAN6ED) 115 IIB A-2 (EXIST. UNCHANGED) A-2 U (ACCESSORY USE TO A-2) 50. FT. OCCUPANCY 4,835 S.F. A-2 (EXI5TIN6) 424 S.F. A-2 880 S.F. U (ACCESSORY USE) d. TOTAL AREA: 6,13'1 S.F. 11. ALLOWABLE AREA: PER VBC TABLE 506.2 o. FIRE SPRINKLERED BUILDING: 24,000 S.F. (EXIST. I -STORY BLDG) *b. ACTUAL BUILDING AREA: 6,139 S.F. * NOTE: INCLUDED NEN CANOPIES IN TOTAL AREA IN CALCULATIONS 12. AREA OF CONSTRUCTION: 1,504 5.F 15. CANOPY HE16HT: o. MEAL DELIVERY CANOPY: 9'-b" BOTT. OF CANOPY b. FACE TO FACE CANOPY W-b" SOTT. OF CANOPY 14. BUILDIN6 SETBACKS o. NORTH PROP LINE: 20'-0" b. WEST PROP LINE: 30`-0" (RICHMOND STATE RD) c. SOUTH PROP LINE: 20'-0" d. EAST PROP LINE: 20'-0" (LUXOR RDJ 15. PARKING REQUIREMENTS: EXISTING TO REMAIN NO CHANCE TO PARKING SPACES OR EXISTING DRIVE THRU LANES. PROJECT DIRECTORY OWNER: CHICK-FIL-A, INC. 5200 BUFFINGTON ROAD ATLANTA, GA 50549 TROY TRIPP, DIRECTOR OF CONST, trog.tripp®cFacorp.com (404) 305-4613 PROJECT MANAGER: BUREAU VERITAS,LLC IT200 N PERIMETER DRIVE SUITE 2-5 SCOTTSDALE, ARIZONA 85255 MICHAEL ANDERSON, GPM (480) Tr-1800 STRUCTURAL: FASHION INC. JASON HOLMES 1019 E. NORTH STREET OTTANA, K5 66061 PH: (185) 242-&111 ARCHITECT: E5ENCIA LLC I"143 E. McNAIR DRIVE SUITE 200 TEMPS, AZ. 85283 JEFFREY HINTER, R.A. wintermesencia.org (480)-m-0959 EXT 120 MEGH. /PLUMB INTERPLAN LLC 604 COURTLAND STREET SUITE 100 ORLANDO,FL. 328O4 BARB MARTIN Bmart in®interp I an I I c.com (401) 645-5008 MUNICIPALITY: ALBEMARLE COUNTY 401 MGINTIRE ROAD CHARLOTTESVILLE, VA 2-MO2 MIKE DELLINGER mdel linger®a Ibemorle.org (434) 296-5832 x4504 GENERAL NOTES A. PRIOR TO COMMENCEMENT OF CONSTRUCTION THE 6.0. SHALL BE RESPONSIBLE TO VERIFY AND LOCATE EXACT LOCATION/DEPTH OF UNDERGROUND UTILITY LINES, COMMUNICATION LINES, ETC. SERVING THIS SITE. IDENTIFY UTILITIES AS TO SCOPE OF WORK AND LOCATION OF DIGGING. B. HHERE REQUIRED. G.C. SHALL NOTIFY ADJACENT TENANTS / PROPERTY OHNER5 OF ANY SERVICE INTERRUPTIONS AT LEAST 48 HOURS PRIOR TO SERVICE INTERRUPTIONS. C. ANY DAMAGES TO UNDERGROUND UTILITY LINES SHALL BE REPORTED TO THE UTILITY COMPANY INVOLVED. O.C. SHALL REPAIR DAMAGES PER UTILITY CO. REQUIREMENTS AT CONTRACTORS EXPENSE. D. UPON INSTALLATION OF FOOTINGS, IT SHALL BE THE 6.0 RESPONSIBILITY TO OBTAIN THE SERVICES OF A LAND SURVEYOR TO PROVIDE TOP OF ASPHALT/GONG. DIVE TOPO POINTS TO THE CANOPY FABRICATOR PRIOR TO CANOPY FABRICATION. SAID LAND SURVEYOR SHALL PROVIDE A DRAHIN6 DEPICTING TOPO POINTS, NO EXCEPTIONS TAKEN. SWPP GENERAL NOTE NOTE TO CITY / COUNTY ENGINEERING DEPT. THE CONSTRUCTION OF THE THI5 PROJECT DOES NOT REQUIRE ANY GUT / FILL OR 6RADIN6. ALL FOOTINGS REGARDLESS OF TYPE ARE EXCAVATED ON THE FIRST DAY OF CONSTRUCTION, EXCESS DIRT HAULED OFF IMMEDIATELY AND DISPOSED OF PER CITY / COUNTY REQUIREMENTS. ALL TRENCHING 15 DUG, ELECTRICAL AND OR GAS LINES INSTALLED, TRENCH 15 BACKFILLED ON THE SAME DAY. NO GRADING ELEVATION5 CHANCES OCCUR NOR DISTURBANCE OF ANY HATER DRAINAGE PATTERNS. PERVIOUS OR NON-PEREVIOU5 AREAS ARE NOT AFFECTED. THEREFORE A STORM HATER PREVENTION PLAN 15 NOT REQUIRED FOR THI5 PROJECT. 5200 BUFFINGTON ROAD. ATLANTA, GEORGIA 30349 (404) 765 - 8000 THESE PLANS AND SPECIFICATIONS, AS WELL AS CHICK-FIL-A, INC. NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF CHICK-FIL-A CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND/OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT CHICK-FIL-A'S PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. esencia 1743 E. McNair Drive, Suite 200 Tempe, Arizona 85283 Telephone 480-755-0959 O�Qi�'Tli OF UC� iro JEFFREY W. WDrM Lic. No. 0I5908 I�RCHI*T V 08-02-2021 Revision Schedule Rev Date By Description r r N � N Q 00 IC) Q V Q M� J J_ 0- 0 Z LL O O w W Q o U m U N 2 a� o a Issue Date: 08-02-2021 Drawn By: TP/GA Job Number: 19060 Sheet Title: Pro'ect Data 09ite Plan Scale: As indicated Sheet Number: A-1