Loading...
HomeMy WebLinkAboutSUB202100194 Review Comments Easement Plat 2022-01-26County of Albemarle Department of Community Development 401 McIntire Road, Charlottesville, VA 22902 Phone 434-296-5832 Fax 434-972-4126 Memorandum To: Scott Collins, Collins Engineering (scotta collins-engineering com) From: Andrew Reitelbach, Senior Planner Division: Planning Date: January 26, 2022 Subject: SUB202100194 Pantops Shopping Center — Easement Plat; 2"d Submittal The County of Albemarle Planning Division will grant or recommend approval of the plat referenced above once the following comments have been addressed: [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] 1. [14-302(B)1] Provide the date of the last revision of the plat on future submittals of this plat. Comment still applies. 2. [General Comment] Deeds for the easements are required. These deeds will be prepared by the Engineering Division and will be required to be recorded along with the easement plat. Comment still applies. Please contact Andrew Reitelbach in the Planning Division at areitelbach&albemarle.org or 434-296- 5832 ext. 3261 for further information. Comments from Other Reviewers: Engineering Division, Community Development Department — Emily Cox, ecox2(a)albemarle.org — Requested changes; see the attached memo. County of Albemarle - COMMUNITY DEVELOPMENT DEPARTMENT �18cit�P Memorandum To: Andy Reitelbach From: Emily Cox Date: 11/23/2021 Rev. 1: 12/30/2021 401 McIntire Road, North Wing Charlottesville, VA 22902-4579 Telephone: 434-296-5832 WWW.ALBEMARLE.ORG Subject: PLAT SHOWING NEW EASEMENTS FOR TMP 78-17G2 PANTOPS SHOPPING CENTER (SUB202100166) The Pantops Shopping Center Plat has been reviewed by Engineering. The following comments will need to be addressed before approval: The SWM facility easement names should be consistent. VARIABLE WIDTH SMF NEW VARIABLE WIDTH ACCESS EASEMENT PUBLIC STORM WATER MANAGEMENT FACILITY & ACCESS EASEMENT Why are there 27 See below: 11, nment addressed. 2. Please consult with the engineer to ensure the easement widths are sufficient per the design standards manual, page 15. There should be a 10' landing for the SWM facility: httos://www.albemarle.org/flome/ShowDocument?id=270 Rev. 1: Comment not addressed. There is only 5' on each side of the SWM facility. 3. Please show the WPO buffer. Rey oai;i�n, a��ires>ai 4. Is what is shown below an existing or proposed easement? If existing, please show the DB & PG. DE14 20' DRAINAGE / EASEMENT ar^ F�3 Rev. 1: Comment addressed. 5. Ensure all easements are labeled as public or private. Rev. 1: Comment addressed. 6. SWM facility and drainage easements will need associated deeds. Engineering will provide these deeds when the plat is ready for final signature. Rev. 1: Comment still applies.