Loading...
HomeMy WebLinkAboutSUB202100071 Correspondence 2021-06-11 W� ENGINEERS SURVEYORS PLANNERS ASSOCIATES TRANSMITTAL To: Cameron Langille Date: 6/11/21 Organization: Albemarle County Community WWA Project No: 217069.04 Development Project: Plat Showing Division of the Property of John W. Finley No. of Copies Description 6 Plats Showing Division of the Property of John W. Finley 1 Comment Response Letter WW Associates, Inc. By: Earl W. Mottley, LS Vice-President 3040 Avemore Square Place •Charlottesville,VA 22911 Telephone(434)984-2700•Fax(434)978-1444 Charlottesville • Lynchburg } . • W..= ENGINEERS SURVEYORS PLANNERS ASSOCIATES June 9,2021 Cameron Langille Senior Planner II, Planning County of Albemarle Community Development Department 401 McIntire Road,North Wing Charlottesville,VA 22902-4579 Re: SUB202100070 John W. Finley Rural Subdivision Plat—First Review Comments WWA Project No. 217069.04 Dear Mr. Langille: We have received your 5-26-21 comments for the above referenced project, and offer the following responses: 1. Comment[14-302 (A)(3)l: Please update the labels for Free Union Road and Catterton Road so that they state the width dimensions of those streets. Response: See"30' Prescriptive Easement" labeled on Free Union Road and to Catterton Road. 2. Comment[14-302 (A)(10)1: Revise note 17 so that it states that the residue of TMP 16-17 and Parcel A may be further divided and when further divided within their 1980 boundaries. Response: "The residue of TMP 17-16 and Parcel A may be further divided and when further divided within their 1980 boundaries"was added to Note 17. 3. Comment[14-302 (A)(11):According to County records, two boundary line adjustment plats have been approved by the County that affect TMP 16-17. These application numbers were SUB201800141 and SUB202000176. The deed book and page number listed on Sheet 1 of the plat states DB 4543 page 90. That recorded instrument is a quitclaim deed and is not either of the aforementioned approved plats. a. Were either of the BLA plats recorded? If so,please state the most recent instrument number that affects TMP 16-17. Response: Both were recorded and SUB202000176 was the latest and recorded in DB 5440 Pg 1 and the Deed that conveyed the land was recorded in DB 5461 Pg 304. These two references were added to the Plat. 968 Olympia Drive,Suite 1 •Charlottesville,VA 22911 Telephone(434)984-2700 •Fax(434)978-1444 Charlottesville•Lynchburg • .11 4. Comment[14-302 (B)(1)l: Please add a last revision. Response: Revised Plat to "June 9, 2021". 5. Comment[14-302 (B)(10)l: Please add a label identifying the line symbology used to identify the WPO Stream Buffers on Sheet 2. Response: Lines are labeled"Water Protection Ordinance Stream Buffer". 6. Comment[14-302 (B)(8)J: Please identify the location of all yards required by this chapter and the zoning ordinance, which may be shown graphically or described in a note on the plat. Response: Added minimum yard requirements to Note 7. 7. Comment [14-303(C)1: Please revise the proposed property boundary for Parcel A. The proposed parcel boundaries do not connect between the Iron Pin Found(IPF) and lines L16/L17. Please be sure that the proposed parcel boundary of Parcel A connects somewhere with the exterior property boundary. Add a measurement for any new proposed property boundaries that are drawn on the plat. Response: Original boundary line did not plot, now boundary line is shown. 8. Comment[14-309, 14-310 and 14-4161: Please submit soils evaluations for review for Parcel A and the residue of TMP 16-17. Once received, these will be forwarded to the Virginia Department of Health (VDH)for review. a. Soils evaluations must be percolation tests or other methods of soil evaluation used to determine the suitability of the soil for subsurface drainfields, if conventional onsite sewage systems are proposed to be used in the development of the subdivision, and the results are requested by the agent. Response: Residue of TMP 17-16 has existing house and existing drain field. Parcel A has 39.606 Ac. that does not require percolation test. 9. Comment [14-316]: The plat has been forwarded to the Virginia Department of Transportation (VDOT)for review and approval of the proposed entrances onto public streets. Any comments or approvals from VDOT will be forwarded to the applicant upon receipt. Response: Awaiting comments from VDOT. We trust that the above responses and revised plans properly address the outstanding items. If you have any questions,please contact me. Sincerely, WW Associates, Inc. Earl Mottley, L.S. Vice President 968 Olympia Drive,Suite 1 •Charlottesville,VA 22911 Telephone(434)984-2700 •Fax(434)978-1444 Charlottesville•Lynchburg