Loading...
HomeMy WebLinkAboutSDP202100065 Review Comments Final Site Plan and Comps. 2022-01-19January 14, 2022 Shimp Engineering Attn: Mr. Justin Shimp, P.E. 201 East Main Street, Suite M Charlottesville, Virginia 22902 Re: Albemarle Business Campus — Block 1 Dear Mr. Shimp: We have reviewed the plans entitled "Albemarle Business Campus — Block 1," dated November 19, 2021. The following comments need to be addressed. General 1. Easements are to extend 10-feet behind FHAs typ. 2. Provide 20-feet easement around meter vaults and lines leading to vaults typ. 3. Show 4-inch gate valves for service lines going to meter vaults typ. Sheet C7 1. Callout 12x8 TS&V and show 8-inch GV for connection to existing water main. 2. Provide easement around Clubhouse meter. 3. Provide minimum 5-feet separation between Bldg. 101-meter vault and mailboxes. 4. Shift FHA 1 GV closer to tee, and shift FHA 2-feet from curb. 5. Refer to attached drawing for how the end of the water main should be configured. 6. Relocate proposed light poles outside of ACSA easements. 7. Refer to attached drawing for Bldg. 102 and 103 service alignments and easement dimension. 8. Include 6-inch GV for Bldg. 102 and 103 fire line. 9. Provie more separation between proposed sewer and DI B3. Relocate light pole outside of proposed easement. 10. Remove proposed stairs from proposed ACSA easement. 11.Remove MH 3A. 12. Provide access easement to MH 4A from Mountainwood Road. 13. Provide 10-feet of separation between proposed sewer and utility pole. Sheet C10 1. Callout crossings over the sewer main. Shallow segment 5A-4A. 168 Spotnap Road 0 Charlottesville, VA 22911 ® Tel (434) 977-451 1 ® Fax (434) 979-0698 www.serviceauthority.org Sheet C11 1. Remove proposed trees from ACSA easement along Country Green Road. Sheet C17 1. Include "Typical Blow Off Assembly Detail". If you have any questions concerning this review feel free to call at (434) 977- 4511, Ext. 113. Sincerely, Richard Nelson Civil Engineer RN:dmg 050601AlbemarleBusinessCampusBIk.1 Comments011422