HomeMy WebLinkAboutSDP202100088 Plan - Revision 2022-02-03V o �o NMHEEM O mmmm .............. ............. COV A Y \0 GA z dCn J � Q W O W O co w U MAJOR IT N AM w�Q EN M E z TMP95A5® �°z N d Q N co N N fn W N SAMUEL MILLER MAGISTERIAL DISTRICT, ALBEMARLE COUNTY, VIRGINIA Q J p J N Uzp�v r U W w co r- z SITE DATA SHEET INDEX ° a OWNER/DEVELOPER : NORTH GARDEN FIRE COMPANY, INC. SHEET # SHEET TITLE O 4907 PLANK ROAD Q 1----------------------------------------- COVER SHEET CHARLOTTESVILLE, VA 22959 \�\ 2 ---------------------------- -- GENERAL NOTES PLAN PREPARER: ROUDABUSH, GALE, &ASSOCIATES � P 999 SECOND STREET 3 - EXISTING CONDITIONS AND DEMO PLAN CHARLOTTESVILLE, VA. 22902 O 4=-----------------`------ ---_----_- ---- LAYOUT PLAN (434)-260-7722 TAX MAP PARCEL No: 09900-00-00-005AO \ 5 ---- GRADING PLAN 09900-00-00-005DOO\� 6----------------------------------------- UTILITY PLAN TOTAL PARCEL AREA: 0.4600 AC (99-5A) 7----------------------------------------- LIGHTING PLAN 0.4450 A 99-5D) 8----------------------------------------- DETAILS 0.905 AC (TOTAL AREA) A TOTAL #SHEETS = 8 ZONING: VILLAGE RESIDENTIAL, ENTRANCE CORRIDOR OVERLAY, FLOOD HAZARD OVERLAY CURRENT USE: FIRE/RESCUE STATION co z PROPOSED USE: FIRE/RESCUE STATION O a 2 MAXIMUM BUILDING HEIGHT: 30 FT Fr 0 m LU SETBACKS: FRONT = 25', SIDE = 15', REAR = 20' o O MAGISTERIAL DISTRICT: SAMUEL MILLER z O CRITICAL SLOPES: CRITICAL SLOPES PRESENT PER COUNTY GIS w WATERSHED: NORTH FORK HARDWARE RIVER WATERSHED ALLOWABLE DENSITY: N/A SOURCE OF TOPOGRAPHY 1' CONTOURS FROM RGA FIELD SURVEY DATED FEBRUARY 23, 2021 w SUBJECT } `� m 0 BENCHMARK: AS SHOWN ON EXISTING CONDITIONS; NORTHWEST CORNER OF POST OFFICE, BM = 694.69' DATUM: HORIZ: NAD 83; VERT: NAVD 88 PROPERTY UJ N_ Q r FLOODPLAIN: THE PROJECT SITE SHOWN HEREON IS LOCATED IN ZONE "X" AND DOES NOT FALL WITHIN FLOOD a HAZARD ZONE "AE" FOR A 100-YEAR FLOOD AS SHOWN ON FEMA MAP 51003CO279D, EFFECTIVE 2/4/2005, THIS DETERMINATION HAS BEEN MADE BY GRAPHIC METHODS, NO ELEVATION STUDY HAS BEEN PREFORMED AS A PORTION OF THIS PROJECT. LL0 FLOODPLAIN INFORMATION - REFER TO SDP199900010 AND SDP199900074 FOR LETTER OF MAP REVISION AND DOCUMENTATION SHOWING THE BUILDING IS NOT WITHIN THE FLOODPLAIN STREAM BUFFER: THE WATER PROTECTION ORDINANCE BUFFER AND THE 100-YR FLOODPLAIN LINE ARE THE SAME LINEWORK n ON SHEET3, EXISTING CONDITIONS. ALBEMARLE z COUNTY oo r� � U a CEMETERIES: NO EVIDENCE OF A BURIAL SITE WAS DISCOVERED ON THE SUBJECT PARCEL. Z immy L. Taggart p ALL WATER LINES, SEWER LINES, AND FIRE LINES FROM THE MAIN TO THE STRUCTURE MUST HAVE A VISUAL INSPECTION PERFORMED BY THE 7J Uc. No. q BUILDING DEPARTMENT. / = A�o� 2%2%22 ESSrONAL ECG THE SUBJECT PROPERTY IS NOT LOCATED WITHIN AN AGRICULTURAL -FORESTAL DISTRICT. THIS SITE IS NOT LOCATED WITHIN THE WATERSHED OF A PUBLIC WATER SUPPLY RESERVOIR. VICINITY MAP SCALE: 1"=1000' z STORMWATER MANAGEMENT COMPLIANCE NARRATIVE Q THIS PROJECT IS ESTIMATED TO DISTURB 5,000 SQUARE FEET, WHICH IS BELOW THE THRESHOLD FOR CONSIDERATION FOR THE FOLLOWING: z A. EROSION AND SEDIMENT CONTROL ORDINANCES L J B. VSMP REGULATIONS O - VIRGINIA STORMWATER QUALITY REGULATIONS r , v Q - VIRGINIA STORMWATER QUANTITY REGULATIONS W W W H-�- QLLJ z cn zg ir 1110- W nui o U APPROVALS � Q� DEPARTMENT SIGNATURE r R 11\MATMPROI01 rn rShetdwn.JpOAllI;5'dfi PM,Antn(AN ppL (f nxA f)nnlmMrflllnnlrcI PLAN NOTES 1. THE OWNER MAY ACT AS THE PROJECT MANAGER OR DESIGNATE A PROJECT MANAGER TO ACT AS OWNER'S REPRESENTATIVE DURING THIS PROJECT. CONTRACTOR SHALL REPORT DIRECTLY TO THIS PROJECT MANAGER UNLESS OTHERWISE DIRECTED. 2. THE DESIGNER HAS CONDUCTED NO STUDIES DESIGNED TO DISCOVER THE PRESENCE OF ANY HAZARDOUS SUBSTANCES ON THIS PROPERTY AND ASSUMES NO RESPONSIBILITY OR LIABILITY RESULTING FROM THE PRESENCE ON ANY SUCH SUBSTANCE. 3. THE CONTRACTOR SHALL OBTAIN ALL PERMITS REQUIRED FOR THIS WORK AND PAY ALL ASSOCIATED FEES. THIS INCLUDES ALL NECESSARY PERMITS INSPECTIONS BONDS, AND OTHER APPROVAL RELATED ITEMS IN ACCORDANCE WITH THESE PLANS AS WELL AS LOCAL, STATE, AND FEDERAL POLICIES. 4. PAVED OR RIP RAP DITCH MAY BE REQUIRED WHEN, IN THE OPINION OF THE RESIDENT ENGINEER OR HIS DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. 5. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES, LATEST EDITION, AND SHALL BE PROVIDED BY THE CONTRACTOR. 6. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). 7. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE VDOT ROAD AND BRIDGE STANDARDS (LATEST EDITION) AND THE VDOT ROAD AND BRIDGE SPECIFICATIONS (LATEST EDITION). 8. RETAINING WALLS GREATER THAN 3 FEET IN HEIGHT REQUIRE A SEPARATE BUILDING PERMIT. WALLS EXCEEDING 4 FEET IN HEIGHT REQUIRE A STAMPED ENGINEERING DESIGN. WALLS REQUIRE INSPECTIONS AS OUTLINED IN THE USBC. 9. ALL WATER LINES, SEWER LINES, AND FIRE LINES FROM THE MAIN TO THE STRUCTURE MUST HAVE A VISUAL INSPECTION PERFORMED BY THE BUILDING DEPARTMENT. 10.WHERE THE FLOOD LEVEL RIMS OF PLUMBING FIXTURES ARE BELOW THE ELEVATION OF THE MANHOLE COVER OF THE NEXT UPSTREAM MANHOLE IN THE PUBLIC SEWER THE FIXTURES SHALL BE PROTECTED BY A BACKWATER VALVE INSTALLED IN THE BUILDING DRAIN BRANCH OF THE BUILDING DRAIN OR HORIZONTAL BRANCH SERVING SUCH FIXTURES. PLUMBING FIXTURES HAVING FLOOD LEVEL RIMS ABOVE THE ELEVATION OF THE MANHOLE COVER OF THE NEXT UPSTREAM MANHOLE IN THE PUBLIC SEWER SHALL NOT DISCHARGE THROUGH A BACKWATER VALVE. EARTHWORK, DRAINAGE, & SITE CONDITIONS 1. EXCEPT AS OTHERWISE SHOWN ON THE PLANS, ALL CUTS AND FILLS SHALL MATCH EXISTING SLOPES OR BE NO GREATER THAN 2:1. 2. UNLESS OTHERWISE NOTED ON THE PLANS OR IN THE SPECIFICATIONS, ALL FILL MATERIALS SHALL BE COMPACTED TO 95% OF THEORETICAL MAXIMUM DENSITY AS DETERMINED BY AASHTO T-99 METHOD A, WITHIN PLUS OR MINUS 2% OF OPTIMUM MOISTURE, FOR THE FULL WIDTH AND DEPTH OF THE FILL. 3. ALL GRADING AND IMPROVEMENTS TO BE CONFINED TO THE PROJECT AREA UNLESS OTHERWISE INDICATED. 4. ALL MATERIALS AND INSTALLATION DETAILS SHALL CONFORM TO APPLICABLE LOCAL ORDINANCES AND VDOT ROAD & BRIDGE STANDARDS (LATEST EDITION) UNLESS OTHERWISE STATED WITHIN THE PLANS.. 5. ANY UNUSUAL OR UNANTICIPATED SUBSURFACE CONDITIONS SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER. 6. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND LOCATIONS PRIOR TO BEGINNING WORK, AND IMMEDIATELY NOTIFY THE PROJECT MANAGER IN THE EVENT THERE ARE ANY DISCREPANCIES BETWEEN SUCH CONDITIONS AND THOSE SHOWN ON THE PLANS AND SPECIFICATIONS. 7. IN THE EVENT THAT GRADING AS SHOWN ON THE PLANS IS NOT FEASIBLE, CONTRACTOR SHALL ADVISE THE PROJECT MANAGER AND ENGINEER BEFORE FINAL GRADING COMPLETION FOR ADVICE AND CONSENT. UTILITIES 1. ANY DAMAGE TO EXISTING UTILITIES CAUSED BY CONTRACTOR OR ITS SUBCONTRACTORS SHALL BE CONTRACTOR'S SOLE RESPONSIBILITY AND REPAIRED AT CONTRACTOR'S EXPENSE. 2. THESE PLANS DO NOT GUARANTEE THE EXISTENCE, NON-EXISTENCE OR LOCATION OF UTILITIES. CONTRACTOR SHALL VERIFY THE EXISTENCE AND LOCATION OR THE NON-EXISTENCE OF UTILITIES. AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION OR CONSTRUCTION, CONTRACTOR SHALL NOTIFY MISS UTILITY (1-800-552-7001) AND/OR THE RESPECTIVE UTILITY COMPANIES FOR GAS, WATER, SEWER, POWER, PHONE AND CABLE. CONTRACTOR SHALL TIMELY ARRANGE TO HAVE THE VARIOUS UTILITIES LOCATED, AND TO HAVE THEM REMOVED OR RELOCATED, OR TO DETERMINE THE METHOD OF PROTECTION ACCEPTABLE TO THE RESPECTIVE OWNER, IF THE METHOD OF PROTECTION IS NOT OTHERWISE SPECIFIED. CONTRACTOR SHALL CONDUCT ITS WORK IN THE VICINITY OF EXISTING UTILITIES IN ACCORDANCE WITH THE RESPECTIVE UTILITYS RULES AND REGULATIONS. ANY COST INCURRED FOR REMOVING, RELOCATING OR PROTECTING UTILITIES SHALL BE BORNE BY CONTRACTOR UNLESS INDICATED OTHERWISE. CONTRACTOR SHALL EXCAVATE TO LOCATE BURIED UTILITIES FAR ENOUGH IN ADVANCE OF ITS WORK TO ALLOW FOR HORIZONTAL AND /OR VERTICAL ADJUSTMENTS TO ITS WORK AND/OR THE UTILITIES. NO ADJUSTMENT IN COMPENSATION OR SCHEDULE WILL BE ALLOWED FOR DELAYS RESULTING FROM CONTRACTOR'S FAILURE TO CONTACT AND COORDINATE WITH UTILITIES. 3. WHEN THE WORK CROSSES EXISTING UTILITIES, THE EXISTING UTILITIES SHALL BE ADEQUATELY SUPPORTED AND PROTECTED FROM DAMAGE DUE TO THE WORK. ALL METHODS FOR SUPPORTING AND MAINTAINING THE EXISTING UTILITIES SHALL BE APPROVED BY THE RESPECTIVE UTILITY COMPANY AND/OR THE ENGINEER. CONTRACTOR SHALL EXERCISE CARE TO INSURE THAT THE GRADE AND ALIGNMENT OF EXISTING UTILITIES ARE MAINTAINED AND THAT NO JOINTS OR CONNECTIONS ARE DISPLACED. BACKFILL SHALL BE CAREFULLY PLACED AND COMPACTED TO PREVENT FUTURE DAMAGE OR SETTLEMENT TO EXISTING UTILITIES. ANY UTILITIES REMOVED AS PART OF THE WORK, AND NOT INDICATED TO BE REMOVED OR ABANDONED, SHALL BE RESTORED USING MATERIALS AND INSTALLATION EQUAL TO THE UTILITY'S STANDARDS. 4. CONTRACTOR SHALL NOTIFY LANDOWNERS, TENANTS AND THE PROJECT MANAGER PRIOR TO THE INTERRUPTION OF ANY SERVICES. SERVICE INTERRUPTIONS SHALL BE KEPT TO A MINIMUM AND SHALL ONLY OCCUR WITH THE KNOWLEDGE AND PERMISSION OF THE SERVICE'S OWNER OR AUTHORITY. 5. THE ADJUSTMENT OF ALL MANHOLE TOPS, WATER VALVE BOXES, GAS VALVE BOXES AND WATER METER BOXES SHALL BE THE RESPONSIBILITY OF CONTRACTOR. 6. ALL WATER METER, VALVES AND FIRE HYDRANT ADJUSTMENTS/RELOCATIONS SHALL BE PERFORMED BY THE CONTRACTOR. CONTRACTOR SHALL KEEP A "REDLINE" SET OF PLANS DOCUMENTING ALL SUCH AS -BUILT REVISIONS. DRAINAGE SYSTEMS 1. CONTRACTOR SHALL EXERCISE CARE, ESPECIALLY AT INTERSECTIONS AND GUTTER LINES, TO PROVIDE POSITIVE DRAINAGE. ANY AREAS WHERE WATER IS IMPOUNDED SHALL BE CORRECTED BY CONTRACTOR AT NO ADDITIONAL COST. POSITIVE DRAINAGE OF ALL ROADWAY AREAS TO THE STORM DRAIN INLETS OR OTHER ACCEPTABLE DRAINAGE CHANNELS AS NOTED ON THE PLANS IS REQUIRED. 2. CONTRACTOR SHALL MAINTAIN EXISTING STREAMS, DITCHES, DRAINAGE STRUCTURES, CULVERTS AND FLOWS AT ALL TIMES DURING THE WORK. CONTRACTOR SHALL PAY FOR ALL PERSONAL INJURY AND PROPERTY DAMAGE WHICH MAY OCCUR AS A RESULT OF FAILING TO MAINTAIN ADEQUATE DRAINAGE. 3. ALL PIPES, DI'S AND OTHER STRUCTURES SHALL BE INSPECTED BY THE PROJECT MANAGER BEFORE BEING BACKFILLED OR BURIED. THE PROJECT MANAGER MAY REQUIRE CONTRACTOR, AT NO ADDITIONAL COST, TO UNCOVER AND RE-COVER SUCH STRUCTURES IF THEY HAVE BEEN BACKFILLED OR BURIED WITHOUT SUCH INSPECTION. 4. ALL CATCH BASINS ENCOMPASSED WITHIN NEW CONSTRUCTION SHALL BE CONVERTED TO DROP INLETS. 5. REMOVED PIPE SHALL BE THE PROPERTY OF CONTRACTOR UNLESS NEGOTIATED OTHERWISE BEFORE PROJECT BIDDING; AND IF NOT SALVAGED FOR RE -USE, SHALL BE DISPOSED OF LAWFULLY. 6. ALL STORM SEWER PIPE AND DROP INLETS SHALL BE CLEARED OF DEBRIS AND ERODED MATERIAL PRIOR TO FINAL ACCEPTANCE. 7. ALL STORM SEWER PIPE JOINTS SHALL BE SEATED AND SEALED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. 8. ALL EXISTING ROOF DRAINS AND OTHER DRAINAGE CONDUIT BLOCKED OR DISRUPTED FROM THEIR PRE -CONSTRUCTION DRAINAGE PATTERNS SHALL BE SHORTENED, EXTENDED OR OTHERWISE ROUTED USING MATERIALS APPROVED BY THE ENGINEER, AND IN SUCH A WAY THAT THE NEW DRAINAGE PATTERNS ARE ACCEPTABLE TO ENGINEER AND THE PROJECT MANAGER. CONCRETE & ASPHALT 1. ALL FORMS SHALL BE INSPECTED BY THE PROJECT MANAGER OR HIS REPRESENTATIVE BEFORE ANY CONCRETE IS PLACED. THE PROJECT MANAGER MAY REQUIRE CONTRACTOR, AT NO ADDITIONAL COST, TO REMOVE AND REPLACE CONCRETE PLACED PRIOR TO OR WITHOUT SUCH INSPECTION. 2. ALL MATERIAL INSIDE FORMS SHALL BE CLEAN AND FREE OF ALL ROCKS AND OTHER LOOSE DEBRIS. SUB -BASE MATERIAL SHALL BE COMPACTED BY MECHANICAL MEANS. 3. CONCRETE SHALL NOT BE PLACED UNLESS THE AIR TEMPERATURE IS AT LEAST 40 DEGREES FAHRENHEIT (F) IN THE SHADE AND RISING. 4. 1/2" PREMOLDED EXPANSION JOINT MATERIAL SHALL BE PLACED AT A MAXIMUM OF 30' INTERVALS ON NEW SIDEWALK, CURB, CURB & GUTTER, AT EACH END OF DRIVEWAY ENTRANCES, AT EACH END OF HANDICAP RAMPS, SOME POINT ON ENTRANCE WALKS AND STEPS ADJUSTMENTS, AND ALONG BUILDINGS AND WALLS WHERE NEW CONCRETE SIDEWALKS ARE PLACED AGAINST THEM. 5. ALL EXISTING CURBS, CURB & GUTTER, SIDEWALK AND STEPS TO BE REMOVED SHALL BE TAKEN OUT TO THE NEAREST JOINT. 6. EXISTING ASPHALT CONCRETE PAVEMENT SHALL BE SAW CUT AND REMOVED AS PER THE SPECIFICATIONS. REMOVAL SHALL BE DONE IN SUCH A MANNER AS TO NOT TEAR, BULGE OR DISPLACE ADJACENT PAVEMENT. EDGES SHALL BE CLEAN AND VERTICAL, ALL CUTS SHALL BE PARALLEL OR PERPENDICULAR TO THE DIRECTION OF TRAFFIC. 7. DISPOSAL OF ALL EXCESS MATERIAL IS THE RESPONSIBILITY OF CONTRACTOR. 8. SEAL (TACK) COAT SHALL BE APPLIED IMMEDIATELY BEFORE ASPHALT IS LAID AND SHALL EXTEND ALONG THE BURIED VERTICAL EDGE OF CURBING UP TO THE ELEVATION OF THE TOP OF THE ASPHALT LAYER. TRAFFIC & SIGNAGE 1. ALL "NO PARKING" REQUIREMENTS SHALL BE PROVIDED BY CONTRACTOR WITH APPROVAL OF THE PROJECT MANAGER. 2. CONTRACTOR SHALL PROVIDE NECESSARY REFLECTORS, BARRICADES, TRAFFIC CONTROL DEVICES AND/OR FLAG PERSONS TO INSURE THE SAFETY OF ITS WORKERS AND THE PUBLIC. TRAFFIC CONTROL SHALL BE DONE WITH THE KNOWLEDGE AND PERMISSION FROM THE STREETS OWNER OR AUTHORITY. 3. CONTRACTOR SHALL MAINTAIN SAFE AND PASSABLE PUBLIC ACCESS TO PROPERTIES AND THE PUBLIC RIGHT-OF-WAY DURING CONSTRUCTION. ACCESS FOR EMERGENCY VEHICLES SHALL BE MAINTAINED AT ALL TIMES. 4. EXCEPT AS OTHERWISE AUTHORIZED IN WRITING BY THE PROPER AUTHORITY, THE WORK SHALL BE COORDINATED AND PERFORMED IN A MANNER SO THAT ALL EXISTING FIRE HYDRANTS SHALL BE ACCESSIBLE AT ALL TIMES DURING THE WORK. 5. CONTRACTOR SHALL NOTIFY AND GAIN PERMISSION FROM THE PROPERTY OWNER(S) TWELVE (12) HOURS IN ADVANCE OF BLOCKING ANY ENTRANCE. NO ENTRANCE SHALL BE BLOCKED FOR MORE THAN TWELVE (12) HOURS IN ANY 24 HOUR PERIOD WITHOUT APPROVAL OF THE PROPERTY OWNER, EXCEPT WHERE NEW ENTRANCES ARE CONSTRUCTED. 6. WITHIN 24 HOURS OF THEIR REMOVAL, CONTRACTOR SHALL REPLACE MAILBOXES, STREET SIGNS, TRAFFIC SIGNS, AND THE LIKE THAT ARE REMOVED FOR CONSTRUCTION. PERMANENT OR SUITABLE TEMPORARY ITEMS WILL BE USED AS THE STATUS OF WORK PERMITS. PERMANENT OR TEMPORARY STOP SIGNS MUST BE IN PLACE AT ALL TIMES. COSTS SHOULD BE INCLUDED UNDER THE VARIOUS UNIT BID ITEMS. NO SEPARATE PAYMENT WILL BE MADE. 1. CONTRACTORS SHALL PERFORM WITH REQUIRED CARE AND PRECISION IN CONSTRUCTION OF ADA (ACCESSIBLE) COMPONENTS AND ACCESSIBLE ROUTES WITHIN THE SITE. THESE CONSTRUCTED PRODUCTS, AS THE CONTRACTOR LEAVES THEM, MUST COMPLY WITH ALL APPLICABLE STATE AND LOCAL ACCESSIBILITY LAWS AND REGULATIONS AND THE CURRENT ADA AND/OR STATE ARCHITECTURAL ACCESS BOARD STANDARDS AND REGULATIONS' BARRIER FREE ACCESS AND ANY MODIFICATIONS, INCLUDING REVISIONS OR UPDATES. FINISHED SURFACES ALONG THE ACCESSIBLE ROUTE(S) FROM PARKING SPACES, PUBLIC TRANSPORTATION, PEDESTRIAN ACCESS, INTER -BUILDING ACCESS, TO POINTS OF ACCESSIBLE BUILDING ENTRANCE OR EXIT, MUST COMPLY WITH THESE ADA OR ACCESS BOARD CODE REQUIREMENTS. THESE INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: 1.1. HANDICAP PARKING SPACES AND PARKING AISLES - SLOPE SHALL NOT EXCEED 1:50 (1/4" PER FOOT OR NOMINALLY 2.0%) IN ANY DIRECTION. 1.2. RAMPS (CONCRETE OR OTHERWISE) - SLOPE MUST NOT EXCEED 1:12 (8.3%) FOR A MAXIMUM OF SIX (6) FEET. 1.3. LANDINGS - MUST BE PROVIDED AT EACH END OF RAMPS, MUST PROVIDE POSITIVE DRAINAGE, AND MUST NOT EXCEED 1:50 (1/4" PER FOOT OR NOMINALLY 2.0%) IN ANY DIRECTION. 1.4. ACCESSIBLE ROUTE PATH OF TRAVEL - MUST PROVIDE A 36-INCH OR GREATER UNOBSTRUCTED WIDTH OF TRAVEL (ENCROACHMENTS SUCH AS CAR OVERHANGS OR HANDRAILS CANNOT REDUCE THIS MINIMUM WIDTH). THE SLOPE MUST BE NO GREATER THAN 1:20 (5.0%) FOLLOWING THE DIRECTION OF TRAVEL, AND MUST NOT EXCEED 1:50 (1/4" PER FOOT OR NOMINALLY 2.08%) FOR CROSS SLOPE. WHERE PATH OF TRAVEL WILL BE GREATER THAN 1:20 (5.0%), RAMP SPECIFICATIONS (ABOVE) MUST BE ADHERED TO. MAXIMUM SLOPE OF 1:12 (8.3%), FOR A MAXIMUM RISE OF 2.5 FEET, MUST BE PROVIDED. RAMPS MUST HAVE ADA HAND RAILS AND "LEVEL" LANDINGS ON EACH END THAT ARE CROSS SLOPED NO MORE THAN 1:50 IN ANY DIRECTION (1/4" PER FOOT OR NOMINALLY 2.08%) FOR POSITIVE DRAINAGE. 1.5. DOORWAYS ALONG ACCESSIBLE ROUTES - MUST HAVE A "LEVEL" LANDING AREA ON THE EXTERIOR SIDE OF THE DOOR THAT IS SLOPED AWAY FROM THE DOOR NO MORE THAN 1:50 (1/4" PER FOOT OR NOMINALLY 2.08%) FOR POSITIVE DRAINAGE. THIS LANDING AREA MUST BE NO LESS THAN 60 INCHES (5 FEET) LONG, EXCEPT WHERE OTHERWISE PERMITTED BY ADA STANDARDS FOR ALTERNATIVE DOORWAY OPENING CONDITIONS. (SEE ICCANSI A117.1-2003 AND OTHER REFERENCED INCORPORATED BY CODE.) 1.6. IF PROJECT INVOLVES RECONSTRUCTION, MODIFICATION, REVISION OR EXTENSION OF OR TO ADA COMPONENTS FROM EXISTING DOORWAYS OR SURFACES, CONTRACTOR MUST VERIFY EXISTING ELEVATIONS SHOWN ON THE PLAN. NOTE THAT TABLE 405.2 OF THE DEPARTMENT OF JUSTICE'S ADA STANDARDS FOR ACCESSIBLE DESIGN ALLOWS FOR STEEPER RAMP SLOPES, IN RARE CIRCUMSTANCES. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE DESIGN ENGINEER OF ANY DISCREPANCIES AND/OR FIELD CONDITIONS THAT DIFFER IN ANY WAY OR ANY RESPECT FROM WHAT IS SHOWN ON THE PLANS, IN WRITING, BEFORE COMMENCEMENT OF THAT WORK. IMPROVEMENTS PLACED BY THE CONTRACTOR MUST FALL WITHIN THE MAXIMUM AND MINIMUM LIMITATIONS IMPOSED BY THE BARRIER FREE REGULATIONS AND THE ADA REQUIREMENTS. 1.7. CONTRACTOR SHALL VERIFY THE SLOPES OF CONTRACTOR'S FORMS PRIOR TO POURING CONCRETE. IF ANY NON-CONFORMANCE IS OBSERVED OR EXISTS, CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER PRIOR TO POURING CONCRETE. CONTRACTOR IS RESPONSIBLE FOR ALL COSTS TO REMOVE, REPAIR AND REPLACE NON -CONFORMING CONCRETE. 2. CONTRACTOR IS URGED TO REVIEW THE INTENDED CONSTRUCTION WITH THE LOCAL BUILDING CODE AFTER FORMS ARE SET AND PRIOR TO COMMENCEMENT OF CONSTRUCTION OR IMPROVEMENTS. ALBEMARLE COUNTY GENERAL CONSTRUCTION NOTES 1. PRIOR TO ANY CONSTRUCTION WITHIN AN EXISTING PUBLIC RIGHT-OF-WAY, INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT). THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS OF THE PERMIT SHALL GOVERN. 2. ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT UNLESS OTHERWISE NOTED. 3. EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN AND SHALL BE INSTALLED PRIOR TO ANY CLEARING, GRADING OR OTHER CONSTRUCTION. 4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED. 5. THE MAXIMUM ALLOWABLE SLOPE IS 2:1 (HORIZONTAL: VERTICAL). WHERE REASONABLY OBTAINABLE, LESSER SLOPES OF 3:1 OR BETTER ARE TO BE ACHIEVED. 6. PAVED, RIP -RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. 7. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES. B. UNLESS OTHERWISE NOTED ALL CONCRETE PIPES SHALL BE REINFORCED CONCRETE PIPE- CLASS III. 9. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). CONTRACTOR'S RECORD DRAWING REQUIREMENTS CONTRACTOR SHALL KEEP ACCURATE RECORDS OF ANY CHANGES SUBSTITUTIONS, ALTERATIONS, VARIATIONS OR UNUSUAL CONDITIONS ENCOUNTERED OR IMPLEMENTED WHILE ENGAGED ON THIS PROJECT. THESE RECORDS SHALL BE IN THE FORM OF "REDLINES". "REDLINES" SHALL REFER TO THE CONTRACTOR'S HAND ANNOTATIONS USING RED COLORED PEN/PENCIL TO DEPICT ACTUAL CHANGE, SUBSTITUTION, OR CONDITION. PRIOR TO CONTRACTOR REQUESTING PARTIAL OR FULL PAYMENT CONTRACTOR SHALL PROVIDE THE OWNER WITH AN UP-TO-DATE CONTRACTOR'S RECORD DRAWING. SPECIFICALLY, THIS SET OF PLANS, ISSUED TO THE CONTRACTOR AS FINAL CONSTRUCTION DRAWINGS, SHALL BEAR THE "REDLINE" MARKINGS LISTED BELOW AS WELL AS THE CONTRACTOR (AGENT OR SUPERINTENDENT) SIGNATURE AND CERTIFICATION BELOW: 1. REDLINES SHOULD ALWAYS BE ACCURATE NEAT, LEGIBLE, DATED AND REASONABLY SCALED. 2. ADD LARGE RED LETTERS TO TITLE SHEET WITH 'CONTRACTOR'S RECORD DRAWING' INCLUDING CONTRACTOR'S NAME, DATE, AND OTHER RELEVANT INFORMATION 3. CONTRACTOR'S REPRESENTATIVE OR SUPERINTENDENT SHALL INITIAL EACH SHEET. IF A SHEET HAS NOT BEEN CHANGED AT ALL OR NO MARK HAS BEEN ADDED, LABEL THE SHEET ONLY'NO CHANGES' 4. IF A SHEET HAS BEEN CHANGED OR MODIFICATIONS HAVE BEEN ADDED, LABEL IT 'REVISED' 5. USE WRITTEN EXPLANATION TO DESCRIBE CHANGES. REFER TO SPECIFIC ACTIONS INSTEAD OF REFERENCING CHANGE ORDER NUMBERS OR RELATED DOCUMENTS 6. USE CLEAR LETTERING 7. NEVER REMOVE OLD VALUES OR DETAILS, JUST REDLINE OR "X" THROUGH THEM. IF THERE IS NO ROOM FOR THE NEW VALUE, YOU CAN GO TO THE SIDE AND REDLINE THE REPLACEMENT VALUE. 8. PROVIDE THE REDLINE DETAILS OF CHANGES OR ADDITIONAL INFORMATION, INCLUDING BUT NOT LIMITED TO FABRICATION, ERECTION, INSTALLATION, LOCATION, SIZING, MATERIAL, DIMENSION, ADDITIONS, RELOCATIONS, SUBSTITUTIONS, ETC 9. BE SPECIFIC WHEN MAKING NOTES TO UNDERGROUND UTILITIES, SHOWING EXACT LOCATION, DEPTH, AND MATERIAL USED (EXAMPLE: SEWER LATERALS) 10. PROVIDE ALL NECESSARY INFORMATION OF CONTRACTOR'S DESIGNED SYSTEMS OR SUBSTITUTIONS 11. CROSS OUT ANY PLAN REFERENCE TO "APPROVED EQUAL" AND REPLACE WITH ANY SPECIFIC INFORMATION OF VARIANCE USED DURING THE CONSTRUCTION PROCESS 12. ANY CHANGES IN INVERT ELEVATIONS, GRADE MODIFICATIONS, SLOPES, AND RELATED INFORMATION ON PIPING UTILITIES, EARTHWORK, ETC. SHALL BE REDLINED. 13. RECORD ALL UNEXPECTED OBSTRUCTIONS, COMPLICATING FACTORS, UNSUITABLE CONDITIONS FOUND IN THE PROJECT AREA INCLUDING ROCK, UNUSUAL TOPSOIL CONDITIONS, BURIED DEBRIS, ETC. 14. ATTACH OR INCLUDE ANY SHOW DRAWINGS OR SUPPLEMENTAL INFORMATION TO THE CONTRACTOR'S RECORD nRAwwr, 15. CHANGES MADE AS A RESULT OF ANY REGULATORY OR OWNER INSPECTION PROCESS CERTIFICATION STATEMENT: THIS HAND -MARKED SET OF DRAWINGS HAS BEEN "REDLINED" TO PROVIDE ACCURATE DETAILED RECORD OF ANY SUBSTANTIVE CHANGES TO THE APPROVED DESIGN DRAWINGS. ANY ITEM NOT "REDLINED" ON THIS PLAN SET OR SUBSEQUENT PAGES SHOULD BE CONSIDERED TO BE "CONSTRUCTED IN ACCORDANCE WITH THE DESIGN AS SHOWN'. NAME, TITLE 1WS 9L•\I0 (CONTRACTOR) m U o m N wrng DNO U) U U' Z ( J m ONf Q (,#) ZO o ��w� z F Ir �Lu Lu Q�� a-2:: Z � _ O U w U U Q � z0 r� O > V W w (F+-1 Iu z z N a 0) d cLu o N N Q U U a n co>o U0J co >=J N Z >LUwww [L cor-Z0rndW jr VcLU+� U F_ Z W O 2 a 2 U O c w z o � U O Z U O W w a= r q m w 0 w N Q r 0 N O f z �o���PVTH of vr�G' U 1. /' ` � 9 Jimmy L. Taggart Uc. No. AP 22841 ww� 0� 2/2/22 1{ ES'SIONAL �1yG z z O LLJ 00 w LLJ cf) W Q O LL z z< W Z C) Lu U c5 UD Q if 0 O z DATE: 11 01 21 SCALE: N/A JOB: 21.2336 SDP: SHEET: 2 OF 8 g1P.GA\TMPROI\212336 Np1M1 GaN¢n Fire CompanryAENGINEERING\OWC\10.1421\01_$hre8\Init Site Plan@ GENERAL NOTESdwg, 2/3/2@21610'S3 AM, OWC To POF p[3 II I II I I I U.S. ROUTE 29 I I I II I I I I I II I I NOTE: NOT FOR CONSTRUCTION. THIS SHEET PROVIDES AN OVERALL EXHIBIT OF EXISTING SITE CONDITIONS, IDENTIFIES FEATURES FOR DEMOLITION, AREAS TO BE PRESERVED AND PROPOSED STREET AND UTILITY CONNECTIONS. EX STORMPIPE STATE ROUTE 692 \l', PLANK ROAD L (VAR. WIDTH RIGHT—OF—WAY) T )1 I \X li — -7 30' OHE EASEMENT (TYR) WHITE TRAr£4C STRIPES \EX. FENCE \ S 62°54'57'" — — — — — — — — — — — — \ S E 55"57" E IO0. O' IRON FOUND - I I O 69 �-�-zs'se 0 -- � I BM /SC=6594.6 I �9 NAIL FOUND W I I I \ \ FF=690.0 �.. I III it I r� o � 49 7 0 0 l \ y KX'9 SL K I I FF=690.0 TMP 86-27 I I III I 0 N/F BOAZ II III IZ 1 \ ❑ I.. .N... MOUNTAIN, LLC DB 3127 PG 18 I I I II w O o I FF=689.3 \m 0 FRAME SHED I 78;r10' I � ao TMP 99-5A I 19,977 SF 0.459 AC PARKING SPACES(X10) CRITICAL SLOPES \ I I II I I I m PER COUNTY G/S �� I III I I IIII Z99- �I��IIII / I I IIIIII j MH - TYPE UNKNOWN \ I I FF=687.2 I 411111 I FRAME 1 II SHED I 11.4'x---- — — — — — — — — — -ILl I I II _ IIII �\ N 62°55'57" t_10»Q-aO, — I ` I I I I I I I I LAMP POST �JI UTILITY POLE (TBR) GRASSY AREA • , � F�0 NNIM ' ' N FF 689 a, a MET R.(REL,� ELECTRIC I\ PANEL (REY 40.1' TMP 99-05 NORTH GARDEN CROSSROADS INC DB 1264 PG 374 YELLOW TRAFFIC STRIPES EX 15"CMP- OUTLET UNKNOWN UTILITYPOLE UTILITYPEDESTAL `1 1RON FOUND JO' OHE EASEMENT (TYP.) TMP 99-5E N/F CUTRIGHT LIABILITY COMPANY OB 2761 PG 262 9� HEAT PUMP 100-YR FLOODPLAIN (GIS) GENERATOR WATER PROTECTION n ORDINANCE BUFFER D HEAT PUMP ASPHALT TO BE REMOVED U FF= 88.6 1 1 J' MATCH EX177NG ASPHALT SECTION :.. . J/49D7 AS REQUIRED 2 STORY •s�•;..:"-3- BRICK I EX. / I 156.0' I 5.0' I I I I I F•t q .L•4 1 I V I s'x`i•'i: :`,,'s::3.: FF=689.0 -4 j I J r% IF N 62°5457" W-- iD&BOT ` /IF _j TMP 99-5E N/F CUTRIGHT LIABILITY COMPANY DB 2761 PG 262 1 1 1 � 1 • 1 1 I I I I I FEATURE TO BE REMOVED (TBR) FEATURE TO BE RELOCATED (REL) CRITICAL SLOPES U o N � N U1 j U zU)�m O J J J C 0 pco 2�wo H rn z ao Ow U O� 0- Z C)_ O U) w U W U Q 'n J _Z Z F3 T� O V cl) LLLL Z s^ N a w LLj N N Q U U Q ~ >Lu to O Q J N U Z - v > O W = LJ LU W O Z arn¢=a U Z W O 2 a 0 U OU U (� w Z 0 � cn O Z U O w CE > (D m w 0 W N Q � N O T z �o���PVTH OF Dr�� r Jimmy L. Taggart Uo. No. 22841 w4� °,3, 2/2/22 1{ ES'SIONAL ECG z nQ g z O O III U o 0 LLJ w o Q LL z U) z o 1 w0 C) � o U) (Q O (O v D �l = Q Z U) W O z DATE: 11 / 01 21 SCALE: 1" = 20' JOB: 21.2336 SDP: SHEET: 3 OF 8 g1P.GA\TMPROI\212336 Np1M1 GaN¢n Fire COmpanry\ENGINEERING\DWC\10.1421\01_$hre8\Ini[ $itt Plan\3 EYJ41NG CONDRION$ PUN dwg, 2J3/2022102029 FM, DWG TO PDF.p6 STATE ROUTS 692 PLANK ROAD (VAR. WIDTH RIGHT-OF-WAY) I 1 I TMP 86-27 N/F BOAZ MOUNTAIN, LLC DB J127 PG 18 CRITICAL SLOPES \ PER COUNTY GIS I W, I 0 I7 25' 5E I \ I` o 0� I \ I I I I I II I I r— TMP 99-5A 19,977 SF n I 0.459 AC � IT I^ . -�I I I OHU—H� SEE RETAINING WALL INSET I 0 I I n I I I I I I I I I I I PN, :mw�. ASSUMED 18" EIAVE � PROPOSED TRENCH DFAIN — I II EXTERIOR WALL TMP 99-5D 19,398 SF 0.445 AC I I lu Im I^ I I II ;)I �a I or- --1a.1 I � 2' I � I I — FOOTER OR INTERIOR WALL (ASSUMED 121 OFFSET) — I � �I INSTALL b IUPST TRENC HID x I I COMM TO BE RELOCATED x AS NECESSARY 6" 21A BASE STONE 5.5' PORTLAND CEMENT W/6X6 10/10 WIRE MESH AND NECESSARY EXPANSION/CONTRACTION JOINTS PROPOSED TIE-IN I I I x I I I I I I x I I I I ❑ I I I x 1 O ) IN x x �� TMP 99-5E N/F CUTRIGHT LIABILITY COMPANY DB 2761 PG 262 TMP 99-05 NORTH GARDEN CROSSROADS INC DB 1264 PG J74 TMP 99-5E N/F CUTRIGHT LIABILITY COMPANY DB 2761 PG 262 LEGEND CONCRETE SIDEWALK RETAINING WALL INSET ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ U o m� w g ENO UQ= UZ d J m OJ Y > Zp(o g�w0 u) O¢ �� QO§ Ow =0C " U 6� Z ¢_ O U w U U Q m Z r� O j � V w F+ 1 LL z N rn d W Ld N N a� Ua� J Lu J N U > m } U U a =www O Z U O w rn tr d a U zzwz O p Jimmy L. Taggart r Uc. No. 22841 0,cES2�2�22( nz O111 �E UowLU ICE QQ zao Q� cl: U) Qif Oo rrOz oYm� U DATE: 11 01 21 SCALE: AS SHOWN JOB: 21.2336 SDP: SHEET: T OF 8 Q\RGA\TMPROI\212336 NdM GaM¢n Fir¢ COmpam2\ENGINEERING\OWG\10-1421\01_$M1ee[z\Init Si. Plan\61AVOIfr PIAN dwry 2920P2162055 AM, Fu[OCAO POF (G¢"<fdl WCumenG[im).p6 U.S. ROUTE 29 I II I I I I I I I I TMP 99-05 NORTH GARDEN CROSSROADS INC DB 1264 PG J74 I I I STATE ROUTE 692 PLANK ROAD — ,'VAR. WIDTH RIGHT-OF-WAY) S 62-54'57" E 0.00' \ S 62'S5'S7" E 100,Q'0' x�— pH � 1 OHU 0 '80' o OHU o \ NAIL IRON FOUND I p \ yAl FOUND "� \ IRON FOUND II h I o ® \ \ \ 90.7b 69 6' SEE 5TAIRC S INSET / III I - - - - I -\ - - 695.5' X s� tY - p - - - - 25' SB - 6 b_ 9 \ 69527'G00' \ I 3 / I bye p I TMP 99 5E 639.9' 689. - J o - - - x N/F CUTRIGHT I - - _ .. - I _ �3 LIABILITY COMPANY v�lll I I \ FF=690.o I T - i �7.;. 694.9' � �- DB 2761 PG 262 FF=689.1 0. 1, FF=690.0 I I 689. / I ' TMP 86-27 I El 78.7' I x q N/F BOAZ I I Iz MOUNTAIN, LLC I III I ro I I DB 3127 PG 18 TMP 99-51- FF=689.3 32. T I I w 19,398 SF c.� I II I I c•; O I ,. 0.445 AC m o I ( m I FRAME SHED FF=689.1 — se o ' I w Ie D I q> > II� III \ I TMP 99-5A j \ \ — — —I FF=692.271 6.0' —� II II I 19,977 SF ^ J I 1 I I I I U� 0.459 AC I I saa.o Saa CRITICAL SLOPES /�� PER COUNTY GIS I I^ o:.,.,� - #4907 I I I I FF 8.6 2 STORY I •'s'.= +" ` BRICK EX. III I _ _ : •t.., : •t.. I Ix \ I��JII � � /'IIW ALL SPOT ELEVATIONS ARE SPECIFIED AT THE FLOWLINE UNLESS INDICATED OTHERWISE. I I I I I I I FRAME SHED 1 1.4 x 20.2' 7.2 ✓ FF=689.0 --�--I —�— I--�—�—i I I \ I 451• /F N 62-5557'• W 10»Q_W' I r` I I — —6&61 ------ � o T \ N 62'54'57" W­ IGG.00�__ l /lF TMP 99-5E N/F CUTRIGHT LIABILITY COMPANY DB 2761 PG 262 689.6 2 691.4 � O 692.6 693.1 693.7 694.3 X X X 3C X X X X 7".RISER (Typ). ----- BUILDING ' EXTERIOR I .\I STAIRCASE INSET -o. STAIRS TO BE SLOPED IN THIS DIRECTION FOR WATER RUNOFF U o m� w g ENO U U) Z d J m OJ Y > U) Z0 o g�w0 on p_ o¢ � Lu <� Ow m " U 6� � Z ¢_ U U w U U Q m z0 r� O j V co w F+ 1 Ll z N rr 0) � a_W LIj N N a� tea^ ~ � O J 0 J Lu N U ZO > m } U m =www O z U O d rn tr d a UIL (:D Dr��gart��1�4'"G z I� z 0LLJ U o Lu w z CE � Q Q a- z Q z w a- Q � m U) CD Q if 0 CE 0 z z o OU U m w z o � O m Z U O w m Y W m � W N � N O T z DATE: 11 01 21 SCALE: 1" = 20' JOB: 21.2336 SDP: SHEET: V OF 8 Q\RGA\TMPROI\212336 NeM GaM¢n Firo COmpam2\ENGINEERING\bNG\10-1421\Ol_$M1ee[z\Init Sit¢ %an\5 GRADING PIAN.dwg, 2J312@21h2129 NM, AO[OCAO POF (GM¢21 �umMGtim) pA U.S. ROUTE 29 1 lal I II SEE MATCHLIN SEWER II I I II II I PR P. PRI ATE 6' I I I I II SA . LAT. SMT �I OVERHEAD UTILITIES STATE ROUTE 892 TO BE BURIED (TYP.) PLANK ROAD — — (VAR. WIDTH RIGHT-OF-WAY) --- ------ --- S — 62°55'S7'" —E 100.00' IRON FOUND TRANSFORMER PROPOSTOED I o TIE IN UTILITIES C — o 25' SB 1— _ W FF= 690.0 \ OI s I I 1 \ I I \ I I FO&WD II O 100.00' EfiT 1! FF=690.0 1 / TRENCH DRAIN TMP 86-27 I o ells N/F BOAZ I2 \ I cn MOUNTAIN, LLC I I w DB J127 PG 18 Ff o o I -----' TMP 99-5D cw 0 I FF=689.3 1 �" 10.,398 SF 445 AC I m FRAME SHED I a I O ro I 78;00' I oN oN aI I CONNECTTRENCH DRAIN INTO EXITING CRITICAL SLOPES PER COUNTY GIS ' 1 /I I I IF 19,977 SF = I nj 0.459 AC o I� I I � I I 1 f FF=687.2 E---------— 1II 04 I ,si HE —I N 62°5557" W 100.00' II 'I I I NOTES: 1. ALL TANKS, PUMPS, PIPING, ELECTRICAL SUPPLY AND CONTROLS TO BE DESIGNED BY OTHERS UNDER SEPARATE COVER 2. ADDITIONAL HOLDING TANKS TO BE EQUALIZED 3. THE NEAREST WATER SOURCE IS LOCATED AT A DRY HYDRANT AT ALBEMARLE CIDER WORKS, 2544 RURAL RIDGE LANE, NORTH GARDEN. 4. THE CALCULATED ISO FIRE FLOW FOR THE BUILDING IS 1,550 GPM (CALCULATION BY OTHERS). 5. ALL WATER, SEWER AND FIRE LINES REQUIRE NEW INSPECTION AND TESTING PROCEDURES. THE ALBEMARLE COUNTY BUILDING INSPECTIONS DEPARTMENT (ACBID) DOES A VISUAL INSPECTION AND WITNESSES THE TESTING OF THE BUILDING DRAIN, WATER SERVICE PIPE AND THE SPRINKLER LEAD-IN CONNECTION. 6. THE DEVELOPER/CONTRACTOR IS RESPONSIBLE TO RETAIN A SPECIAL INSPECTOR AS OUTLINED IN THE UPDATED ALBEMARLE COUNTY POLICY FOR SITE UTILITIES TO PERFORM THE VISUAL INSPECTION AND TESTING OF ALL UTILITIES NOT COVERED BY THE ACSA OR ACBID. THIS INCLUDES BUILDING SEWERS, WATER AND FIRE LINE BRANCHES BETWEEN MAIN AND THE METER(S)/BUILDINGS(S). 7. THE SPECIAL INSPECTOR'S REPORT MUST BE SUBMITTED ND APPROVED BY ALBEMARLE COUNTY ENGINEERING PRIOR TO CERTIFICATE OF OCCUPANCY BEING ISSUED. TRENCH DRAIN SYSTEM p FF=688. s: FF; 698.6 3' I s5.0' I � ` PROPOSED UTILITIES `TO BE BURIED (SEE DETAIL SHEET 8) IRON FOUND II x W _ — �T _— — — 01 _r— FF=698.2 32.7' I EX. WATER LINE (TO _ I � 1 BE RE -LOCATED) I 1 I` x I I =p 0.1' Ix 4SEE SEPTIC TA( Kd& Ej I (BY OTHERS) 32.7' 0 FF=689.1 I � ig Eh .0' I �' — FF=692.26.0" oti I 1 x J/4907 2 STORY BRICK I EX. 156.o'I x❑ I I I I I I I I x — — 45-1 = NQ O IF N 62°54'57" W 100.00' IF TMP 99-5E N/F CUTRIGHT LIABILITY COMPANY DB 2761 PG 262 1 1 20 40 .1 1 — —1( 7 i ANGLE FOR CONNECTION TO EXISTING TBD — DIRECTIONALLY BORED (2) 2" SANITARY FORCE LINE FROM HOLDING TANK (DESIGNED BY OTHERS) II ��( I II SEE MATCHLINE THIS SHEET 20 0 20 40 60 SCALE: 1"=20' CONNECTION TO EXISTING SEWER I 1500 GALLON HOLDING kNKS W/ DUPLEX PUMP SETUP y ESIGN BY OTHERS) a d er's 8"s 8"5 I / Q I 0 � 0 GAL 'TIC ey JK ro' I a I ad $ I I a I 10 0 10 20 SCALE: 1"=10' SEPTIC TANKS INSET M 4" CLEANOUT CONNECTION POINT UG PROPANE STORAGE TANKS m U o m N W W � co • 5 j UU) Z (1) - m O Y J Q �II Z0 0 w:C:I) �4 rr<m zo§ = <� Ow U a- Z O Er _ U w U U Q � Z0 r� O j � V w (7 F�+-1 W Z N a 00)) D w N N a� tea^ � -6 J J N ^ U Z J V 1'r�ll >0wa O0)00 = w W CoLU Z o rn ir IL U H Z O ffm U OU U w Z U O Z U O co w a-- > C7 m W w N r (] N O f Z Q)� ,yTH OF DrpC a 2, Jimmy L. Taggart Uo. No. 4 22841 ww� 0,2/2/22 1e ES'SIONAL �1yG z z O LLJ U ❑ LLJ w z Q z z< w a J C) L LL U) Q if O O z DATE: 11 01 21 SCALE: AS SHOWN JOB: 21.2336 SDP: SHEET: 6 OF 8 g1P.GA\TMPROI\212336 Np1M1 GaN¢n Fire Companry\ENGINEERING\DWC\10.1421\01_$hre8\Ini[ $itt Plan\6 Utility Pldn dwq, J3/202210.19A1 NM, DW6 TO PDF pf3 DURA-TRENCH AS MANUFACTURED BY ERIC'SONS 296 N INDUSTRIAL BLVD DALLAS, GA 30132 770-505-6575 W W W.DURATRENCH.COM INFO@ERIC-SONS.COM 121124DIF GRATE WITH 4 CORNER LOCKING SYSTEM F-- 7" MIN. INVERT a 2" X 2" X'g" GALVANIZED STEEL FRAME WITH 3" X 0II" CONCRETE ANCHORS 12" O.C. INSTALLATION BRACKETS FOR HFI.D. ALIGNING AND ANCHORING TRENCH SLAB THICKNESS 0(AS SPECIFIED) w a TI CONCRETE a a ENCAPSULATION (4" MIN) MONOLITHIC POUR REINFORCE PER STRUCTURAL REQUIREMENTS POLYMER TRENCH BODY COMPACTED EARTH ., �-i Ell! -1L�- �ll-lei= r- i/4 INSTALLATION BARI-I (BY OTHERS) - - - - NOTES: 1. STANDARD SLOPE IS 0.5% UNLESS OTHERWISE SPECIFIED 2. REINFORCE ACCORDING TO STRUCTURAL REQUIREMENTS 3. TRENCH DRAIN MUST BE J" BELOW FINISHED CONCRETE GRADE TYPICAL DTPFIO-EXGS15TEA TRENCH SECTION TRENCH DRAIN SECTION APPROVED AS NOTED: Scale: NTS, REVSE&RESL IAT: DURA-TRENCH AS MANUFACTURED BY ERIC'SONS 296 N INDUSTRIAL BLVD DALLAS, GA 30132 770-505-6575 W W W.DURATRENCH.COM INFO@ERIC-SONS.COM NOTES 1. GRATE MATERIAL IS CAST DUCTILE IRON, GRADE 60-45-12 2. MEETS FAA AC: 150/5320-513 & 6E LOADING REQUIREMENTS 3. GRATES ARE MADE IN THE USA 4. GRATES BOLT DOWN AT ALL 4 CORNERS W/ }' 0 S.S BOLTS 5. GRATES ARE HOT DIP GALVANIZED 6. GRATE OPEN AREA 84.67 IN.2/LF 1'-118" -� 1' la THE TRENCH DRAW LAYOUT HAS BEEN DEVELOPED FROM DRAWHOS OR SKETCHES PROV ED TO EMC'SONS. PLEASI REVIEW AND VERIFY OUR INTERPRETATION. AYYXVVE REVISE& 12B24DGF DUCTILE IRON GRATE GRATE DETAIL Scale: NTS 12B24DGF ISOMETRIC VIEW I I 1-1 11-1 I NO BEDDING III -III -III I I �-1 I �-1 I BELOW CONDUIT o -III-III-III co III -I -I -I I -I I I -I I y 3 f 3 II; II II; II I I„ 6'� {~12' 2x 3" BURIED ELECTRIC CONDUIT BURIED UTILITY DETAIL (TYP.) ..019T02 I TRENCH DRAIN SECTION t2T010 J.D.P. M.D.W. TD-301 NTS Ml 6/29/2021 END VIEW ..owicii GRATE DETAIL •2TO10 J.D.P. L.R.C. IIIIlffi TD-SO1 NTS III 3/27/2020 rs -1 1 1-1 1 11-1 1 1-1 1 1- 3" PHONE CONDUIT & 3" ISP CONDUIT TMP a6-. N/F B01 OUNTAIN, J127 P HANDICAP SIGN DETAIL NO SCALE COLORS 2 FINISH AS FINISH GRAD[ EARTH CONCRETE FOOTING ACCESSIBILITY HANDICAPPED PARKING SIGN -DETAIL 1 NOTES: 1. THIS DRAWING IS THE PROPERTY OF CADDETAILS.COM, LTD. AND HAS BEEN MADE AVAILABLE TO DESIGN PROFESSIONALS FOR INFORMATION PURPOSES ONLY. 2. DUPLICATION AND DISTRIBUTION OF THIS DRAWING IS STRICTLY PROHIBITED. 3. DO NOT SCALE DRAWINGS. 4. DO NOT USE FOR CONSTRUCTION. 5. FOR UPDATES AND ADDITIONAL INFORMATION VISIT www.CADdetails.com. PROTECTED BY COPYRIGHT - 04/29/04 www.caddetails.corri ROUTE 692 ADA COMPLIANCE EXHIBIT 20 0 20 40 60 SCALE: 1 "=20' HANDICAP PARKING SPACE DETAIL NO SCALE WUUUI rUAID DAIID SYMBOL SPECS. 5'0" tj 3'0" ACCESSIBILITY HANDICAPPED PARKING SPACE NOTES: 1. THIS DRAWING IS THE PROPERTY OF CADDETAILS.COM, LTD. AND HAS BEEN MADE AVAILABLE TO DESIGN PROFESSIONALS FOR INFORMATION PURPOSES ONLY. 2. DUPLICATION AND DISTRIBUTION OF THIS DRAWING IS STRICTLY PROHIBITED. 3. DO NOT SCALE DRAWINGS. 4. DO NOT USE FOR CONSTRUCTION. 5. FOR UPDATES AND ADDITIONAL INFORMATION VISIT www.CADdetails.com. BY COPYRIGHT - 04/29/04 WWW.Ca TMP N/F C LIABILIT, DB 276 NOTE; THE CDNTRACTGR IS TO USE CONCRETE WHEEL STOPS OR EQUIVALENT. GROUT HOLE FULL HOLE FOR 1/2" STD. PIPE OR 3/4" DIAM REINF ROD CONCRETE WHEEL STOP 2. PLAN VIEW 8 �\ END VIEW 6.5" ELEVATION VIEW 6" HT. ANCHOR SITES 6.5" FROM ENDS, 1/2" STD PIPE OR 3/4" REINF ROD SHALL BE PLACED PRIOR TO SURFACING OR IN A HOLE DRILLED IN THE FINISHED SURFACE WITH A TIGHT FIT OR DRIVEN INTO THE SURFACING AT LEAST 1.0' WHEELSTOP DETAIL NO SCALE U m 6 m N W W � ENO U) UU' j Z J m Y J Q IOI^^ Z F Ir T Q OW U Z � 0_ O U w U U Q � Z r� O j V � w (7 F�+-1 W Z N 0 (r d 00)) N N coU Q m Q ~ O JJ ^ N U C]Z J V r C) W LU 1'r�ll = LU W U L Z 0� o 04 rn jr CL Q 2 U co Z w O 2 2 a OU U co W Z O m Z U O m W m CD ED W m W N Q r 0 N O f Z �O4 'yj H O Fggart vr�G' � J2y9 Ul No. 22841 w4� �,z, 2/24 1{ E'?SIONAL 0. z n z 0 � 00 LJJ Lu Q U) zQ z Q LLJ a_ LLJ r-) Q L UD Q if 0 O z DATE: 11 01 21 SCALE: AS SHOWN JOB: 21.2336 SDP: SHEET: V OF 8 a1P.GA\TMPR0I\212336 Np GaNn Fire Cmpany\ENGINEERING\DWG\10.1421\01_Shre snit Site Plan\E DETAIMd",, 2/3PW2 W2228 AM, DWG To PDF p3