HomeMy WebLinkAboutSDP202100095 Review Comments Initial Site Plan 2022-02-08401 McIntire Road, North Wing County of Albemarle Charlottesville, VA 22902-4579 COMMUNITY DEVELOPMENT DEPARTMENT Telephone: 4 34-296-5832 W W W.ALBEMARLE.ORGRLE.ORG Memorandum February 8, 2022 Kevin Pennock 4805 Lake Brook Dr. Suite 200 Glen Allen, VA 23060 kpennock@dewbeny.com RE: SDP202100095 — ACSA Avon Maintenance Yard — Initial Site Plan SRC Review Comments Dear Mr. Pennock: The Site Review Committee has reviewed the development proposal referenced above. Initial comments from the following divisions of the Department of Community Development and other agencies, as applicable, are attached: Albemarle County Planning Services (Planner) Albemarle County Engineering Services (Engineer) Albemarle County Architectural Review Board (ARB) Albemarle County Information Services (E911) Albemarle County Building Inspections Albemarle County Department of Fire Rescue Albemarle County Service Authority (ACSA) Virginia Department of Transportation (VDOT) Rivanna Water and Sewer Authority (RWSA) Virginia Department of Health (VDH) Comments reflect information available at the time the development proposal was reviewed and should not be considered final. However, the Site Review Committee has attempted to identify all issues that will be required to be resolved prior to approval of the initial site plan. Please contact me at your earliest convenience if you have questions or require additional information. Sincerely, All �G- Kevin McCollum Senior Planner I Albemarle County Planning Services (Planner) —Kevin McCollum, kmccollum@albemarle.org —Required changes: Comments to be addressed prior to initial site plan approval: 1. [32.4.2.1 (f)] County records show that the required $448.00 notification fee has not yet been paid. This fee will need to be paid prior to Friday, February 25, 2022 in order for the initial site plan to be approved. Comments to be addressed prior to final site plan approval: 1. [32.5.2(a)] Please include a reference to the Initial Site Plan Number: SDP202100095 and include a place holder for the Final Site Plan Number. Clarify that SDP202100063 is the Pre -Application Plan Number. 2. [32.5.2(a)] Please provide the total number of sheets at the bottom of the Drawing Index (sheet table) on the Cover Sheet. 3. [General Comment] Add a date of revision. 4. [32.5.2(a)] For any adjacent parcels visible on the drawings, please show the property lines and include a label stating the owner's name, TMP number, zoning districts, and present uses. a. It appears everything but present use has been provided. 5. [32.5.2 0)(k)(1), 32.6.2(g)] Show all existing and any proposed easements. Any new easements required for water, sewer, drainage facilities, or any proposed utilities will need to be reviewed, approved, and recorded prior to final site plan approval. Please submit an easement plat application the County for review. The final site plan will need to be updated so that all easements are shown and labeled identifying easement type, whether it's public or private, a width dimension, and the recorded instrument with deed book and page number. 6. [General Comment] Please copy the Proposed Use table on Sheet CO.07 over to the Cover Sheet. a. Please correct the maximum permitted height which is 35' not 40'. b. [4.12] The Zoning Administrator will need to confirm the proposed number of parking spaces prior to Final Site Plan approval. 7. [Section 32] Final site plan must comply with all applicable requirements of Section 32.6, 32.7 and 32.8 of the Zoning Ordinance prior to final approval. 8. [32.6.20)] Provide a landscape plan that complies with Section 32.7.9. 9. [32.7.8 and 4.17] If any outdoor lighting is proposed, please provide a lighting plan will need to be included with the final site plan submission that complies with all applicable regulations specified in Section 4.17 of the Zoning Ordinance. This includes: a. Provide footcandle measurements within the property and along all property lines. Use a light loss factor of 1.0 to determine footcandles on site. b. [4.17.4 (a)] Provide manufacturer cut -sheets for all proposed outdoor luminaires. c. [4.17.4 (a)] All proposed outdoor luminaries exceeding 3,000lumens must be hill -cutoff fixtures. Please provide documentation from the manufacturers that all fixtures will be full -cutoff. d. Please state the pole height of all outdoor luminaires. e. [4.17.4 (b)] Please add a note to which states "Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-half footcandle." 10. [32.7.9.7 (a)(3)] Please provide a construction detail in plan and profile view of the proposed dumpster enclosure. The detail should identify materials to be used, color, dimensions, etc. Please contact Kevin McCollum at the Department of Community Development at kmccollum@albemarle.org or 296- 5832 ext. 3141 for further information. Comments From Other Reviewers: Albemarle County Engineering Services (Engineer) — John Anderson, janderson2&albemarle.org — Requested changes, see attached. Albemarle County Architectural Review Board (ARB) —Margaret Maliszewski, mmaliszewski@albemarle.org—No objection. Albemarle County Building Inspections — Betty Slough, bslou hg &albemarle.org — Requested changes, see below. Add the following note to the general notes page: Where the flood level rims of plumbing fixtures are below the elevation of the manhole cover of the next upstream manhole in the public sewer, the fixtures shall be protected by a backwater valve installed in the building drain, branch of the building drain or horizontal branch serving such fixtures. Plumbing fixtures having flood level rims above the elevation of the manhole cover of the next upstream manhole in the public sewer shall not discharge through a backwater valve. 2. Add the following to the general notes page: All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks. 3. Add the following note to the general notes page: All water, sewer and fire lines require NEW inspection and testing procedures. The ACSA performs any testing and inspections of the public sewer and water main(s). The Albemarle County Building Inspections Department (ACBID) does a visual inspection and witnesses the testing of the building drain, water service pipe and the sprinkler lead-in connection. The developer/contractor is responsible to retain a Special Inspector as outlined in the updated Albemarle County Policy for Site Utilities to perform the visual inspection and testing of all utilities not covered by the ACSA or ACBID. This includes building sewers, water and fire line branches between the main and the meter(s)/building(s). The Special Inspector's report must be submitted and approved by the Albemarle County Engineering Department prior to a Certificate of Occupancy being issued. Albemarle County Information Services (E911)—Elise Kiewra, ekiewra@albemarle.org—No objection. Albemarle County Department of Fire Rescue — Howard Lagomarsino, hlaQomarsinogalbemarle.org — Requested changes, see below. During construction, the following fire prevention steps are required, so please note them on the plan: a. Smoking shall be prohibited in areas where smoking makes conditions such as to make smoking a hazard and these areas shall be designated with no smoking signs per Virginia Statewide Fire Prevention Code. b. Areas where smoking can occur, shall have appropriate receptacles for discarded smoking materials per Virginia Statewide Fire Prevention Code. c. Per the Virginia Statewide Fire Prevention Code, vehicular access for firefighting shall be provided at all construction and demolition sites, provide access to within 100 ft. of temporary or permanent fire department connections, and have no overhead wiring or other overhead obstructions lower than 13 ft. 6 inches; this access may be via permanent or temporary road, but shall be capable of supporting fire apparatus in all weather conditions. d. Contractor shall ensure the street numbers are always plainly visible from the frontage street during construction per the Virginia Statewide Fire Code e. An approved water supply for firefighting operations shall be in place and available as soon as combustible materials arrive on site. f. Waste and combustible debris shall be removed from the building at the end of each day and disposed of in accordance with the Virginia Statewide Fire Code g. Fire extinguishers shall be provided, with not less than one approved fire extinguisher at each stairwell, on all floor levels where combustible materials have accumulated, in every storage and construction shed and in areas of special; hazards, such as where flammable and combustible liquids are stored or used, in accordance with the Virginia Statewide Fire Code h. Operations involving the use of cutting and welding shall comply with the Virginia Statewide Fire Prevention Code and shall require a permit from the Albemarle County Fire Marshal's Office Albemarle County Service Authority —Richard Nelson, melsongserviceauthority.org—No objection. Virginia Department of Transportation — Doug McAvoy Jr., douglas.meavQy@vdot.viryinia.gov — Requested changes, see attached. Rivanna Water and Sewer Authority —Victoria Fort and Dyon Vega, vfort@rivanna.org and dvega@rinavvan.org — Requested changes, see below and attached. General: 1. Please include RWSA general water and sewer notes (attached). 2. A booster station would be suggested considering the elevation and distance from the tank. Sheet C 1.02 : 1. Please show 6" drain line coming from RWSA Water Tank (attached). 2. Please show the tank drainage path. This would follow the elevation lines from the drain line and rip -rap. Virginia Department of Health — Alan Mazurowski, alan.mazurowski@vdh.virginia.gov — No objection. �q oe nt 401 McIntire Road, North Wing Charlottesville,VA22902-4579 County of Albemarle Telephone: 434-296-5832 m COMMUNITY DEVELOPMENT DEPARTMENT WWW.ALBEMARLE.ORG Initial Site Plan review Project title: Albemarle County Service Authority Avon Maintenance Yard Project file number: SDP2021-00095 Plan preparer: Kevin Pennock, PE, koennock@dewberry.com Dewberry Engineers, 4805 Lake Brook Drive Suite 200, Glen Allen, VA 23060 Owner or rep.: Alexander Morrison, PE, aorrisonAserviceauthority.org Albemarle County Service Authority 168 Spotnap Road, Charlottesville, VA 22911 Plan received date: 29 Dec 2021 Date of comments: 28 Jan 2022 Review Coordinator: Kevin McCollum Reviewer: John Anderson, PE Engineering review comments (for Final Site Plan approval): 1. G0.01 a. Please remove SWM-related sheets C6.06-C6.07 (include with WPO202100071). b. Please revise Civil sheet Drawing Index: strikethrough ESC /SWM-related sheets not included with SDP202100095. 2. C3.01 a. Please submit retaining wall design, when available, at earliest convenience. Wall ht.>4-ft. requires sealed non -generic retaining wall design. Wall ht.>3-ft. requires building permit, and safety railing. C5.01 typical for CMU block retaining wall is generic. Provide specific design, including geosynthetic length of anchoring embedment, plan/profile with wall stationing, etc. b. Provide retaining wall handrail labels, ref. C5.01 detail. c. Provide CG-6 for 14 parking spaces on west side of parking west of building, or CG-2 if flow line is designed into the paved surface near rear wheels of parked vehicles. C3.03 indicates 2.0% paved grade away from west side of building, and provision should be made for storm runoff capture and conveyance. If flow line in pavement, provide surface storm runoff capture at south end of parking on west side of building. Runoff may not exit pavement to an unpaved verge, though runoff may exit to a hard surface surrounding a grate inlet (set in a concrete frame, for example). 3. C3.04 a. Provide outfall design (recommend MH) to redirect flow (SWM facility discharge) such that it aligns with riprap. Design provided does not include element/s sufficient to redirect discharge at outfall. We anticipate discharge may skip over and escape riprap, and cause erosion downslope. A physical structure, preferably MH, is needed to redirect flow so it aligns with riprap. b. Ensure proper ditch lining on south side of site access. Ditch extends —1,140 LF with vertical fall of— 80' (elev.: 608' - 526% and likely requires blanket matting, or riprap armor. Provide velocity calculations as well as lining type. Provide typ. sections for different sections of ditch. Engineering Review Comments Page 2 of 2 \J/ V IV 4. C4.05: Recommend sanitary sewer profile Note /label requiring 95% compaction for fill beneath Str. C05 and pipes to either side since installed in substantial fill section. 5. C4.06 a. STMI, STM2, and pipe between: recommend storm sewer profile note Aabel requiring 95% compaction. b. Although 0.50% is acceptable as minimum pipe grade, length of pipes (168' 212') at Min. grade leaves no room for error during construction. As -built pipe slope < 0.50% requires hydraulic calculations to ensure self-cleaning velocity is maintained throughout reach of pipe. Slopes < 0.50% may require post -installation remedy /expense. It appears that pipe slope between STM 1 and STM2 and between STM2 and STM3 may be increased slightly. Engineering recommends increase pipe slope slightly, to 0.60% or more (0.38' vertical, if an additional 0.1% over 380'). c. Provide VDOT SL-1 label on profile (safety slab) for MH STM3, STM4, STM7. d. Provide VDOT SL-1 detail on the plans. 6. C4.07 a. Provide 95% compaction labels /notes for fill sections at STM15 (and pipes to either side), entirety of STM 19 to STM 21 profile, and STM 17 outfall, and pipe at outfall. 7. C4.08: Revise LD-347 table to include IS-1 (inlet shaping) for MHs with change indirection of flow: STM3, STM6, STM 15, for example. Table lists IS-1 for MHs 7, 5, 4, only. Thank you. Please call if any questions — tel. 434.296-5832-x3069, or email ianderson2(a),albemarle.org. SDP202100095_ACSA Avon Maint Yard 012822 COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION Stephen C. Brich, P.E. 1401 East Broad Street (804) 7862701 Commissioner Richmond, Virginia 23219 Fax: (804) 7862940 January 6, 2022 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Kevin McCollum Re: ACSA Avon Maintenance Yard — Initial Site Plan SDP-2021-00095 Review # 1 Dear Mr. McCollum: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as prepared by Dewberry Engineers, Inc, dated 3 December 2021, and offers the following comments: 1. What is the design vehicle (type and length)? 2. Please review the entrance radii with respect to the Design Vehicle and ensure they conform to Table 4-3 of Appendix F of the Road Design Manual. 3. At the Founder's Place entrance, ensure there is enough space between the gate and the back -edge of the sidewalk for the design vehicle to sit while the gate opens. 4. Provide turn -lane warrants. 5. Ensure the entrances are appropriately spaced from other entrances and intersections according to the Road Design Manual. If not, they will require an Access Management Exception. 6. Provide sight -distance triangle and profiles along the sight -distance lines for both entrances and ensure they conform with Table 2-5, Appendix F of the Road Design Manual. 7. Show the location of the card reader for the automatic gates. 8. Note that the final plan must show conformance with the VDOT Road Design Manual Appendices 13(1) and F, as well as any other applicable standards, regulations or other requirements. Please provide a digital copy in PDF format of the revised plan along with a comment response letter. If further information is desired, please contact Doug McAvoy Jr. at (540) 718-6113. VirginiaDOT.org WE KEEP VIRGINIA MOVING January 6, 2022 Attn: Kevin McCollum A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the Charlottesville Residency Transportation and Land Use Section at (434) 422-9399 for information pertaining to this process. Sincerely, Doug McAvoy Jr., P.E. Area Land Use Engineer Charlottesville Residency Rivanna Water & Sewer Authority (RWSA) General Water & Sanitary Sewer Notes Last Revised: April 2016 1. All materials and methods of construction shall comply with the latest version of the General Water and Sewer Design and Construction Standards — Version 1.0, adopted in December 2015, except as modified below or modified in special notes. 2. RWSA shall approve all construction materials and methods of construction. A preconstruction conference shall be held with RWSA prior to the start of any work. 3. The contractor shall be responsible for notifying Miss Utility (1-800-552-7001). 4. RWSA Engineer (Victoria Fort at (434) 977-2970 ext. 205) shall be notified three business days prior to the start of construction. 5. All work is subject to inspection by RWSA staff. No tie-ins to the existing system shall be made without coordination with and the presence of RWSA staff. No work shall be conducted on RWSA facilities on weekends or holidays without special written permission from RWSA. 6. For sanitary sewer line construction: RWSA may require bypass pumping for tie-ins to the existing system. All doghouse manholes must be pressure -tested before a connection is made to the system. 7. The location of existing utilities as shown on the plans is from data available at the time of design and is not necessarily complete or accurate. The Contractor shall be responsible for the verification of the location, size and depth of all existing utilities, both surface and subsurface. The Contractor shall immediately notify the Engineer of any discrepancies between the plans and field conditions. The Contractor shall use due diligence to protect all utilities and structures from damage at all times, whether shown on the plans or not. Damage to any existing utilities shall be repaired by the Contractor to the original condition at no additional cost to the Owner. 8. Erosion and sediment control facilities shall not be permitted in the RWSA easement without special written permission from RWSA. No grading shall be permitted in the RWSA easement unless permitted otherwise by RWSA in writing. 9. No blasting shall be permitted within 100 feet of RWSA facilities without written permission and RWSA approval of the blasting plan. Ground monitoring during blasting and a pre -blast survey may be required. For blasting within 100 feet of any operative RWSA sewerlines, bypass pumping and/or pre- and post -CCTV may be required. RWSA may also require certification from a licensed professional engineer stating that the proposed blasting will not damage any RWSA facilities. Damage to any utilities due to blasting shall be repaired by the Contractor to the original condition at no additional cost to the Owner. 10. The contractor shall observe minimum separation requirements for utility crossings. When a crossing is made under an existing facility, adequate structural support shall be provided for the existing pipe. The area of the crossing shall be backfilled with compacted 57 stone to the springline of the existing pipe. 11. New water main installations shall be pressure tested, chlorinated, flushed and have water samples approved prior to making any permanent connection to the public water system. Approved methods of filling and flushing new water mains will be required to prevent any contamination of the public water system. 12. All easements for new RWSA facilities shall be recorded prior to placing the new facilities into service. 13. No permanent structural facilities will be permitted in the RWSA easement. This includes building overhangs, retaining walls, footers for any structure, drainage structures, etc. 14. Trees are not permitted in the RWSA easement. CHART 1 FAA „ • •7'.".dA7tafi Ret afa/Mt'.Ila1Pf :'irf.Tll}'- If>�ISafa rmll.•alaY afllfA CY NOTIrY RU&r v Miw ►, iMI AT (804) 2W-5WI FOR 414FANG AND AN THE r x a' « ACCURACY TOLERANCES OF 50FEET* HOAVZONIAL AND 20 PrETI VERIZOALn ROUGH OMMO OF &#LDING.. FENCED AWA AND VICINITY MAP 1" = 2000' LAVAL 10"CRIPTION SITUATED tN SCOTTSVILLE DISTRICT, ALBEMARLE COUNTY, ORGINIA Commencing at the intersection of the southern right-of-way line of U.S.- Route 64 and the easterly ri�h t-of-way line of Route 742 thence with ?old easterly rigrC-of-wayy tine of Route 742 a distance of 3771 to o point, said point berDq tfre westerly corner of Parcel 18 as des noted an a plot entitled ilLAT SHOWING BOUNDARY OF 11,799 AC. �('ted'D OF PARCELS 1, 1A, 1B & 1E TAX MAP 91 AS SHO►94V ON A PLAT IN D.B. 360 p. 191 LOCH fED ON STATE RQUTE 742 AVON STREET EXTE'NDEP ALBEMARLE COUNTY VIRGINIA , being the westerly corner of sold Parcel 18, and being the northerly corner of a 50' right-of-wa , thence with the southerly lane of said Parcel TB South 49 degrees 23 minutes 50 seconds East a distance of 240.54 feet to a found rod, said rod being the westerly corner of Parcel 1 - thence with the southerly line of said Parcel 1 South 4� degrees 23 minutes 50 seconds East a distance of 7tr19.57 to the intersection of the centerline of a proposed 20 access easement and the southerly line of Parcel 1; thence along the centerline of the 20' access easement North 40 degrees 36 minutes 10 seconds East a distance of 3357 feet to a point lyincl on the southerly, lease line; thence with the southa y tease line North 07 degrees 49 minutes 32 seconds West a distance of 10.24 feet 0r a set rod, said rod being the southwesterly corner of the lease area and the true 4 �- thence the following f GlNNIN . lace o � point n BC GINNING. o! a P seconds Cc( �t) thence North 26 degrees 70 min�rtes 28 s East a distance of 70.00 feet to a set rod; {2 thence South 61 degrees 49 minyt 32 seconds East a is once of 60.00 feet to a set rod; {,3y'thence South 28 degrees 10 minutes 98 seconds West a lstance of 70.00 feet to a set rod; 4) thence North 61 degrees 49 minutes 32 seconds West a distance of 60.00 feet to a set rod, said rod being the true point and ppace of BEGINNING and containing 4,200 square feet or 0.096 acres, more or less. PARCEL 1 owned by Albemarle County Service Authority 1. MAXIMUM NUMBER ORLOYE£S: 2 EMPLOYEES AND 1 TRUCK Z MAXIMUM AMOUTIMPERVIOUS COVERAGE - 5.347 SQUARE FEET 3 EXISTING ZONING IS RA -RURAL AW-4S. EC -ENTRANCE CORRIDOR AND AIA- AIRPORT IMPACT AREA 4. ZONM Of A0,/40ENT PARCELS IS RA -RURAL AREAS 5. THE USE IS FOR CELLULAR MOWER ALLOWED 8Y SP-96-04 6. THIS SITE MUST COMPLY WIN THE SUPPLEMENTAL REGULATION OF OF SECTION 6:1.12 7. MAXAAW HEIGOr - 100' $ No, IMPROVEMENTS YO 7HE EVSRW ENT74ANCE WLL BE MADE. 9. BUILDING HFIGN^T.r9' M POWER WILL BE UUIMRGROUND FROM PIS.£ OCF-4 P00P0= QNTERUNE OF TOWER DATA ! TOOER HEiGHr - 100' (MlNVOP044 LA77TWE = 37'5952.3" (NAD 83) LOA07U E 78*29 5a. 9" 83) LLD ELE VA77ON = 80.E O (NA W 88) M PROPOSED PROPOSED MONOPOLE FEN CE �� R=4, D=8, ,%(SEE DATA) ~OSED 4' X 8' CONGRE7F i. PAD FOR Ft)W AW (�MA: W WOULD BE 1Lx3' o A 55I F-C NlAWEV LIIAT) 8a Ha, PROPOSED , 12' 3' X 3' E", BLDG.COAV/7 , TO, PROPOSED 7' Fes: GATES LEA$E AREA(4.200 $01VA�18t FEET) ENTRE LASE AREA 10 B CLEARED, ORAPED AND GRAVELLED. ROUTS TO SC SET AT ALL LEASE AREA COAWM 4. INSTALL DRAINAGE DITCH AND a4W DAMS 5 BEGIN BURRING AND TOWER CONSTRUCIlON! 6. PLACE BASE STONE ON DRIVE AREAS. 7. SEED DENUDED AREAS AS SOON AS POSSYBIF AND MULCH ALL DISTURBED AREAS Ll NO EROSION CONTROL DEVICE 91ALL BE REMOVED LWM AN ADEQUATE STAND OF GRASS HAS BEEN 08TAINED 1. UNLESS OTHETRWISE INDICATED ALL VEGETAL7LE AND STRUCTURAL EROSON AND SEDIMENT CONTROL PRAC77CES WELL BE PONSMU07ED AND MAINTAINED ACCORMG TO MINIMUM STANDARDS AND SPECIRCA77ONS OF THE�AND SEDIMENT =77a HANOkAND VIRGINIA REGULARS�S-N2-00 EROSION AND SEDIMENT CONTROL REGULA 70VS, 2. THE PLAN APPROVING AUTHORITY MUST BE NOWED ONE WEEK PRIOR 70 711E PRECONSIRUC77ON CONFERENCE ONE WEEK PRIOR TO COMMENCEMENT OF LAND DISTURBING AC77WTY, AND ONE WEER PNOR TO FINAL INSPECTION. 3 ALL EROSION AND SEDMENT CONTROL MEASURES ARE TO PLACED PRIOR TO OR AS THE FIRST STEP IN IXEARIN& 4. A COPY OF TFI£ APPROVED EROSION AND SEDIMENT 1XWIROL PLAN SHALL BE MAINTAINED ON 1Hf 9IF AT ALL TIMES 5. THE CONTRACTOR 6 RESPONSWLE FOR ANSTALLAIM OF ANY AOOITKWAL EROSION CON7ROL MEASURES NECESSARY 70 PREVFNr EROSION AND SEDWENTA17ON AS DM MINED BY THE PLAN APPROVING AUTHORITY, 6. w CONTRACTOR SHALL /NSPECr ALL fwgx CONTROL M£A5uas PERIODICALLY AND AFTER EACH RUNCI'F-PROPUaW RAINFALL EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN 7HE EFFECTIVENESS OF THE EROSION! CONTROL DEVICES SHALL BE MADE IMMEIXAIRY. 1. PERMANENT OR TEMPORARY SOL STAEWZ47ION SHALL BE APPLIED TO DENUDED AREAS WI7HW SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY POR7TON OF THE SITE, ArWP- ORARY SUIL STABILIZ4770N SHALL BE APPLIED Wf7MN SEVEN DAYS TO DENUDED AREAS THAT MAY Nor BE AT FINAL GRADE BUT WILL REMAIN DORMANT (UNUSTURBED) FOR LONGO? THAN 3o DAYS PERMANENT STAeluZA77ON SHALL BE APPu6D To AREAS THAT ARE TO Be LEFT DORMANT FOR MORE THAN ONE YEAR. Z SEA/ML74T BASINS AND TRAPSI PE I METER DYKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED To REAP SE'DIMENr SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND-O/S7URBlNG ACTIVITY AND .SHALL BE MADE FVNC710NAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. R 3. STABHUZATION MEASURES SHALL Be APPLIED 70 EARTHEN STRUCTURES SUCH AS DAMS, DICES AND DIVERSIONS IMMETUATELY AFTER INSTALLA710M. 4. WHERE CONS7RUC770N VEHICLE ACCESS ROUTES INTERSECT PAVED PUBLIC ROADa PROVISIONS SHALL BE MADE To MINIMIZE THE TRANSPORT of sawmT SY (VEHICLE) 77m0avG ONTO THE PAVED SURFACE. WHERE SEDIMENT MANSPOR70 ONTO PUBLIC ROAD SURFACE. THE ROAD SHALL BE CLEANED 7HOROUGHL.Y AT 7HE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM IHE ROADS BY SHOVEUNG OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED Oft Y AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION SFIAU APPLY To INDIVIDUAL SUBDAISION LOTS AS WELL AS TO LARGER LAND - DISTURBING AC7 WTE1 a ALL 7EMPORARY EROSION AND SEDIMENT CONTROL MEASURES SMALL BE REMOVED W ININ 30 DAYS AFTER FINAL SITE SrABILIZA77ON OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDW, UNLESS OTHETNISE AU7HO4RIZED BY THE LOCAL PROGRAM ADMINISTRATOR. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE =P097740N OF TEMPORARY MEASURES SHALL BE PERMANENTLY SrAB1UZED 7O PREVENT FURTHER EROSION AND elm"l�►'1Pr',,7►tM' � = lihas t ING SCHEDULE' DISTURBE0 AREAS WILL BE SEEDED WMIHIN 30 DAYS A i E+r asANCE _ 'CHT DISTANCE 90'+ IN EACH OREC77ON \ O GRAPHIC SCALE 30 so A. CORZa &H SELOW (1) OU NDS PER 0 FT GROUND LWSTONE OR Ea#VALENr. NO SOS, A ;�,(1 ��r2 e 1 FORHMENT (2) 20 POUNDS OF 10-10-10 FERTILIZER OR EQUIVALENT PER 1,000 $a FT. (5) VARIE77ES TO BE SEEDED: s� (v) SUMMER SEEDNNa MAY 1ST - AUGUST 1ST, RED FESCUE; 4 POUNDS PER !Cal L (b) AU LIMN SEWM AUGUST 1$T - NOMOM 1519 K&XA f'Y 31 rALL FESCUE PER 1,000 s'o. In: (ra 9R11ING SEEDIN& MARCH 1ST - APRR XIM 9lV G OAr,• 23 POUNDS PEN (d) MULCH: 100 POUNDS OF STRAW PER 1,000 $o FT., ALL SEEDING IS TO A. SEEDING SCHEDULE. DISTURBED AREAS WILL BE SEEDED WIHI4 30 DAYS A,'rear GKADING IN ACCORDANCE WIN BELOW" (1) 10 POLINDS IN EER t O EA/F7. GROUND Li 1ESTOAC OR EQUIVALENT. NO SO'L TEST 6 REQUITED FOR (2) 14 POUNDS OF tO-20-10 FERT7 IM? OR EWVALENT PER 1,000 So. FT (3) VARIETIES TO BE SEEDED: (a) summix, SErawa MAY 1ST - AUGUST 1ST, 4 W/A4 MILLET• 50 CBS: PIER ACRE (b) AUTUMN SgMa AUGUST 1ST - FEMRUARY 2804 50/50 MIX AW44L RYEWASS a KNMR RT£ 50 LBS PER ACRE (c) SPRANG SEEDING: MARCH 1ST - APRIL JOIN, ANNUAL RYEGIRASS: 60 LBS PER ACRE: (d) MULCH: 100 POUNDS OF STRAW PER 1,000 SG: FT., ALL SEEDING IS TO BE MULCHED. PAD (wry won �7gRGE: NIRGINIA EftOBON MD SWkENT cEN1VgX KgMIWL 1264 M HD. P{.AM 3.05-2 i PP fAN190 OV£RHEAO POWER, JELEPHONE, AND CA TV ( IN FF.E 7 1 1 inch = 90 ft. LEGEND: P - POWER P.O.B.- POINT OF BEGINNING T - TELEPHONE LINE BEARING DISTANCE L 1 N 40 36'10" E 33.51 ' L2 N 2870'28" E 70.00' L3 S 61 4932" E 60.00' L4 S 2870 28" W 70.00' L5 I N 6149'32- W 60.00' ((1 ROD FOUND f 10 PAfiCrL I \ ALBAArARZJ` CDU/VTY SA'RYICA' AZ ThVR1TY Z / EX. WATER LINE AS SHOWN ON ALBEMARLE J / COUNTY SERVICE AUTHORITY G Vk PLAN -A VON STREET PROPOSED 24.s6w, _A LINES LOCATED T TAPPING SLEEVE AND f �Cs1� / -(' VALVIE / �T (APP*CIMMA7E LOCATM) } s A*W WITH THRt/ST BLOC! ` 1 _-. � (A 6" DRAIN LINE PROPOSED 6" P►6' ExS77NC WGATEIRLITE WATER ��- Y, TANK \ (47' H104) 70+A TER M F fASfArFNT a; E7L ROAD s� \� p METER POLE",,/ I 120 \T? PP 0 f EX FE74CE l y \ 3.-r1'CNMi1RK \ 9�Sj• s• \1 r� tl' l \ c N P%_ WF, PLj Pdli l �a \ \ \ P -o GATE `\ �:' \ EX FENCE a j PRavosw r- sa NG GRAVEL ROAD FwaPos FTfaE' HYL7R ASS I(SEE DEi \ EX FA + 60 \\ s x�•! µ .//� = is �4. �.da�t' Fes; / (SERE WAIL) TAX J(wy .9f = PIA NOIY [1R1tdR�Y - AlLp+OSED 1 i PARIIAdf 6VAVFATZT10jVEQUIP. Zt D6 I ,VB .348, M 185 TO TIE IN BROKEN BNCK (1/2 NOSE: USE RETAn ' Gd AAVS CU. YD) ON GA 7F VALVE 1. WURX SHALL BE SYUBJ£CT TO INSPECTION BY ALBEMARLE COUNTY SERRWa AUTHORITY INSPECTOM THE CONTRACTOR WLL BE REVONN$1LSE MR N07V MG INE PROPER SERVICE AUTHORITY OFROALS AT THE START OF THE 00W. t 7HE LOCA77ON OF &VS17NG U17UM ACROSS THE LINE OF THE PROPOSED *OW ARE Nor NAY SHOW ON THE PLANS AND WHERE SHOWN, ARE ONLY APPRGWATfi^Y CORRECT: IW COIM40FO1R SHALL ON HIS OWN IM17AIIW LOCATE ALL UNDERGROUND LINES AND SMUOTIURES AS NECESSARY. J. ALL MATERIALS AND CONSTRUCTION SHALL COAFLY WITH GOVERAL WATER AND SOW CONSIAVC77011II SPIs07P70A71ON+S-AS ADOPTED BY NNE AUWmARLE COUNTY SawcE ALITHomrr ON, JANUARY 24 1984 AMENDED AILY 1, ISM 4 DAI7UM FOR ALL ELEVATIONS SHOW AV AE17701NAL GEODEAC SURVEY. V .da 8J r Y: AL�F L1.. a j PROPOSED UIXYIY WIN % �\FENCEr i t (324 SQUA0W FEE0 ! } I ? wet rl TROD FOUND WA77p4TAL DATUM 9 EO O ON M B3 AND 774E l¢;W1TCAL 94SM 1S BASfH) ON NAiQ7 BbL SUfi7VEYL5 BASSO ON PLAT RE'C0WED WT7H DEED BOWC 106i9 A PAw em PLAT ENTITLED (PLAT SHOWMAN BOWAVARY OF It 799 A.C. CCA#ICW OF PARCaS 1, IA, JB, .4 1E TAX MAP 91 AS SHOWN ON. A PLAT I4 ID.O 3SO A 191 LOCATED ON STATE ROUTE 742 AVOY STREET EX?EWM*BY R0UA4&U5P4 GALE & As=, I4C.wL r Z' - r 21-8 STONE SURGRADE \� (D0VMSTfMM 4WWOW d TAPM WM OF a isOR ALVOS SMALL 4,0E ro 9 eW,.:"' CCAW AOW." A�&�i� #��e6��e. '_x .Y' AND x.. ~1044NCES AFE TO = LOCATED +fir ��s rPU9r m►*a ayb a OF d a J 00CHM oa - dlw�i+siNl'Mmm91ri7WM9iwaWilYytlYq`4.. ass d + i�. • , d ,=t, .ra sr c, d a. a .N.. ,a a- y..i. a aw+:a. r e antine «E wa w i i , a' 'x TRa. CHECK a . , _ a 660W, � " r. , OMON s. V tea, ,y , r... y .V c , r . Ai 8' 1t1tAE7 � irM•Lxt TtVltifi ltii?".thi 4OLIE 49IMi7Rd OXIO 10 FOO WYffY LOCAUM 1'e«3D' NO ANTAL or ALL 'Zonvo 5 -$ WAX S MU&'tt,LVO 1`••5d I9kTi"A t (BON Ni9WitllfliALLr AND VI RDaALLY) JyPfa& TO START MLF MW Avon Street Water Storage Tank AVT - 002 Flat File #45 w ui < *z Na 24781 � a L l�(J 4 �o. _.S'iti 0 sJd�a�x cIu�` e. OTHERS I ur Rt - / I I AT L I MI-t-aF i rj T n WORK LN E 3 \ SEE GENE L CIT 4 &I TE 1 PLU ' \ I l 2 " \ 24" \ f 1LO 1 � ►y- � I' � ,` VAU T � 0 oz I i \ 57.5' 0-4 \ m �� \ L - G 172, 3/41, C W \ ELE N TES 10'Ca' ON In. I I t00 3 SSE 5M 41, \ 9 I G' HIGH CHAIN LINK \ 10+ \ 1 U 1 i FENCE t I I RIGN \ W 1 � :D Q \ uw Oc 0, \ w �U U ELEC \\ E \ MOTE I k 10 �04� -� SE ICE DRO X 0� �- ELE . RTC MOTE 2. -R 742 9+� c� _ / R EX IsrING -�/ \ � � � GRE EIfOAD _ _QED GREEN5TON OUTCROPPING � MARK` /O� TWO C2) PK IV J DRIVEN IKITO VEPCO uj END OF POWER POLE NO. CF 4-1 ELEV, (017.38 EAST SITE PLAN 5CALE I"=20' RED- BROWN CLAY DECOMP05ED TO FRACTURED GREENS TONE FIN GR--, I� 2 E PROVIDE i2" MIN SELECT GRANULAR FILL. UNDER RINGWALL FOUNpATION E 1lST GR �' OILED- SAND COSH IOkv i2"(MIN1 SELECT GRANULAR FILL WATE R TAN K G oe C*ECT NE\ C AGGREGATE PVMTrj TO EXST - 0 AGGREGATE ROAOa o< t1+82' ha 11 O INV G i �It5� I TR AGGREGATE PAVEMENT u. PROPOSED a GR � SELECT GRANULAR EXST GE -� FILL FIN GR a`(4 OTHERS 2411 KEMO\/E. ALL CLAY AND REPLACE AS SNOwN 599,70 C EL, 595 C TYPICAL SECTION SNOWNG WATER TANK SUSGRAD NO SCALE PARATION W O W ov 0 IN O -.------- 51 ` 3 5 , 4 VARIES IS" RIPRAP -TYPICAL SECTION 3.2 l SCALE: I 51 3 Bit THICK RIPRAP Ilt 8 �232' l � x \ T0MN1IATE VA LT DRAIN T 'TOE E G' WJI E RtPRA tall THICK LN D I N�CCORbAN H t-t T RCND A D \ x $IR10GE 5TANDAi� I b YP A; NOT GROUTED. VALVE VAU LT G4©, 50 WATER MAIN PROFILE SCALE II'= 2a HOR I'L. I" = 5' VERT STRUCTURAL NOTES 1. CLASSIFICATION OF CONSTRUCTION - TYPE-2C, IN ACCORDANCE WITH THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE (SECTION 401.0/BOCA 1984). 2. VALVE VAULT TOP SLAB DESIGN LIVE LOAD IS 300 PSF. 3. MATERIALS: CONCRETE -CLASS A f' = 4000 PSI REINFORCING BARS c ASTM A 615 GRADE 60, DEFORMED FY = 60 K$I ALLOWABLE BEARING CONCRETE - 1400 PSI FOUNDATION BEARING CAPACITY - 5000 PSF 4. NO FOUNDATION CONCRETE SHALL BE INSTALLED UNTIL ALL FOUNDATION WORK HAS BEEN COORDINATED WITH UNDERGROUND UTILITIES. 5. ALL REINFORCEMENT SHALL BE DETAILED, FABRICATED AND PLACED IN ACCORDANCE WITH ACI 315-80 UNLESS OTHERWISE SHOWN. MINIMUM SPLICE LENGTHS AND EMBEDMENT LENGTHS SHALL BE AS TABULATED THEREIN. 6. UNLESS OTHERWISE SHOWN, REINFORCEMENT AT WALL CORNERS AND INTERSECTIONS SHALL BE DETAILED AS SHOWN ON FIGURE 11 OF ACI 315-80. CORNER REINF SHALL BE DETAILED AS SHOWN FOR OUTSIDE LOADED CORNERS. INTERSECTIONS SHALL BE DETAILED WITHOUT DIAGONAL REINF. ALL LAP SPLICES SHALL BE CLASS C. 7. MAJOR CONSTRUCTION JOINTS ARE SHOWN ON THE DRAWINGS. CONSTRUCTION JOINTS MAY BE ADDED, OMITTED OR RELOCATED IF PROPERLY DETAILED ON SHOP DRAWINGS AND APPROVED BY THE ENGINEER. ELECTRICAL SYMBOLS -- CONDUIT RUN EXPOSED HATCHED LINES DENOTE NUMBER OF CONDUCTORS WHEN OTHER THAN TWO. LA -lam HOME RUN, NUMBER OF ARROWS DENOTE NUMBER OF CIRCUITS LETTERS AND NUMBERS DESIGNATE PANEL AND CIRCUITS. INCANDESCENT LIGHTING FIXTURE, WALL MOUNTED -6" UNLESS INDICATED OTHERWISE. MH 5' S SINGLE POLE SWITCH, MH 4'-011 . DUPLEX RECEPTACLE, MH 4'-011. I DISCONNECT SWITCH. ® PANELBOARD, MH 6'-0" TO TOP. UC P UNDERGROUND CONDUIT AND WIRING, POWER. UCT UNDERGROUND CONDUIT, EMPTY, TELEPHONE. GENERAL NOTES 1. SURVEY'.INFORMATION WAS PROVIDED BY THE OWNER, AND PREPARED BY ROUDABUSH, GREENE, AND GALE, INC. OF CHARLOTTESVILLE, VIRGINIA ON MARCH 20,1 1987 AND MAY 189 1987. 2. SURVEY DATUM USED IS 0.12' HIGHER THAN USGS DATUM. DATUM 15 NOT CONFIRMED 3. INSECT SCREENS SHALL BE PLACED ON THE TANK DRAIN, VALVE VAULT DRAIN; TANK OVERFLOW, AND TAtQK VENT AND 5HALL CONSIST OF 5TAINLE55 STEEL SCREEN W ITN A 4 MESH OPENING, 4. CAP END OF 241' WATERMAIN FOR FUTURE CONNECTION BY OTHERS, (41-OII �1 V11 n/ D D GY,(o W19xW?.9 WWF REINFORCEMENT SECTIDI�1 NO SCALE 3 8. CONTINUOUS REINFORCING IN WALLS AND SLABS MAY BE SPLICED, AS REQUIRED, PROVIDING BARS ARE OF THE LONGEST PRACTICABLE LENGTH AND ALL SPLICES ARE SHOWN ON REINFORCING SHOP DRAWINGS. WHEREVER POSSIBLE, SPLICES SHALL BE STAGGERED. FIELD CUTTING OF REINFORCEMENT WILL NOT BE PERMITTED. 9. UNLESS OTHERWISE NOTED, PROVIDE CONCRETE PRO- TECTION FOR ALL REINFORCING IN ACCORDANCE WITH PARAGRAPH 7.7 OF BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-83). 10. PROVIDE DOWELS TO MATCH REINFORCEMENT IN ALL WALLS, SLABS, AND BEAMS. 11. SPREAD REINFORCEMENT AT OPENINGS AND SLEEVES UNLESS OTHERWISE SHOWN. DO NOT CUT REINFORCEMENT. 12. CONCRETE WALLS SHALL BE TEMPORARILY BRACED AGAINST EARTH PRESSURE AND OTHER FORCES UNTIL 70P SLABS ARE IN PLACE AND HAVE ATTAINED REQUIRED STRENGTHS. 13. PROVIDE WATERSTOPS IN ALL CONSTRUCTION JOINTS. 14. THE CONTRACTOR SHALL VERIFY THE SIZE AND' LOCATION OF ALL OPENINGS, SLEEVES, INSERTS, ETC., WITH SHOP DRAWINGS OF THE EQUIPMENT TO BE INSTALLED, ;AK0 NpTIFY THE ENGINEER OF ANY CONFLICTS, 15, THE TANK SHALL CONFORM TO AWWA D100-84; EXCEPT AS OTHERWISE SPECIFIEO OR' LNDICA,7 ELECTRICAL NOTES 1. METER BASE AND NONFUSIBLE 100A DISCONNECT SWITCH IN NEMA 3R ENCLOSURE SHALL BE MOUNTED ON 25' CLASS 6 POLE. METER BASE SHALL BE FURNISHED BY VEPCO AND INSTALLED BY THE CONTRACTOR. DISCONNECT SWITCH AND POLE SHALL BE PROVIDED BY CONTRACTOR. 2. EMPTY 3" CONDUIT FOR FUTURE TELEPHONE SHALL BE STUBBED UP 1211 ABOVE GRADE AND CAPPED AT VEPCO POLE. CONDUIT SHALL BE STUBBED OUT 6" IN5ICEWALL AND CAPPED WHERE IT ENTERS VALVE VAULT. 3. PAD -MOUNTED RECTIFIER FOR CATHODIC PROTECTION SYSTEM. CATHODIC PROTECTION SYSTEM TO BE PROVIDED AS SPECIFIED. 4. PROVIDE NONFUSIBLE 30A DISCONNECT SWITCH IN NEMA 3R ENCLOSURE FOR HEAT TRACE CABLE IN VALVE VAULT. 5. THE EQUIPMENT PAD SHALL BE A 4'x4' CONCRETE PAD, 6" THICK, WITH 6x6-W2.9xW2.9WWF REINFORCEMENT. PANEL L A VOLTAGE 240/120 V _ I 3 �nI1RE IDO AMP BUS 100 AMP MAIN BRKR CKT BRK9 COMO CK7 DESCRIPTION LOAD -KVA CKT 5RKIZ C0ND CKT, DESCRIPTION LOAD-KVA 40 P AMP N0, SIZE A B C 30 NO. P AMP NOISI A B C 30 I �70 2 12 VAULT LTG 0.4 2 I �20 2 12 VAULT RCP 0,2 3 1 to L) 2 4 RECTIFIER G.5 4 1 20 2 12 HEAT TRACE 0.1 5 1 20 SPARE G I (00 SPARE 7 1 20 SPARE S 1 20 'SPARE 9 SPACE 10 SPACE ' I 1 I -Fri SPACE 12 SPAC E TOTALS 0.4 :0.2 0.1 TOTAL CONNECTED LOAD 7.2 KVA -1 /_-30.0'711�CDVIJG pICN IIV VIA GIV 1..CC� MVVM1Gv/11G ICVnL REVISION 1O DJATEO L. L DESCRIPTION +4BY8PP DESIGNED DMH ANON STREET WATER IMPROVEMENTS PROJECT NO, 87-2 DRAWN JLJ ALBEMARLE COUNTY SERVICE AU7H0RITY y CHECKED ' '~j� ALBEMARLF_ COUNZ`(, VIRGINIA AL APPROVED }`` SITE PLAN; NOTES AND DETAILS SUBM I TTED WHIZ 1878 HAYES, SEAY. MATTERN $ MATTERN SCALE COMM. �38I r ARCHITECTS - ENGINEERS - PLANNERS A,5 5'-omW No. L}205 F ROANOKE, VIRGINIA DATE15 MAY 87 SHEET