Loading...
HomeMy WebLinkAboutSDP202100077 Plan - Approved Minor Amendment 2022-01-263 c VIRGINIA SETBACKS AND BUILDING HEIGHT Cml COMMERCIAL ZONING DISTRICT 7/22/2020 Albemarle County, VA Code of Ordinances Sec. 4.20 - Setbacks and stepbacks in conventional commercial and industrial districts. Setbacks and stepbacks shall be provided as follows: a. Conventional commercial districts. The following shall apply within the C-1, CO, and HC districts: Setbacks j Front -Minimum 10 feet from the right-of-way or the exterior edge of the sidewalk if the sidewalk is outside of the right-of-way; for off- street parking or loading spaces, 10 feet from any public street right-of-way Front -Maximum 30 feet from the right-of-way or the exterior edge of the sidewalk if the sidewalk is outside of the right-of-way, provided that this maximum setback shall not apply to any structure existing on June 3, 2015 and to any structure depicted on an approved final site plan that is valid on June 3, 2015 as having a front setback greater than 30 feet; none, on any lot, including a corner lot, abutting a principal arterial highway or interstate Side and Rear -Minimum If the abutting lot is zoned residential, rural areas, or the Monticello Historic district: (i) no portion of any structure, excluding signs, shall be located closer than 50 feet from the district boundary; and (ii) no off-street parking or loading space shall be located closer than 20 feet to the district boundary. If the abutting lot is zoned commercial or industrial, any primary structure shall be constructed and separated in accordance with the current edition of the Building Code. Side and Rear -Maximum None Figures Figures 1 through 6 are for illustration purposes only. If there is a conflict or inconsistency between a regulation in section 4.20 to which a Figure pertains and the Figure itself, the regulation is controlling. In addition, Figures 1 through 6 merely illustrate specific requirements and do not show all applicable requirements of the applicable district regulations. Figure 1 Conventional Commercial Districts Abutting Nomrssldentlal Districts Naer and ripe 01d. "W o building code c "a.. OROW orW ., efaw+ai..d .•I acid. of NOW No —.1— Yorn sed ace Yong Ddr." arueul. Figure 2 Comentionai Commercial Districts Abutting Residentlal or Rural Areas Districts I Rear •A' i I 1 Side SO"I I i I i Fran: ............ _.. _t0_m n,.`..... ---1—.._..._... Edgeof .............._I.... ..-1--.............. ROW., eldMelk. II owslde of ROW m Imurr. f om seloacN eon rind el arterials ' No Bx g p D Sec. 21.4 - Height regulations. Except as otherwise provided in section 4,10, structures may be erected to a height not to exceed 65 feet. The minimum stepback requirements for any story that begins above 40 feet in height or for each story above the third story, whichever is less, in height shall be as provided in section 4,20. (§ 20-21.4, 12-10-80; 9-9-92; Ord, 15-18(4)_, 6-3-15; Ord, 17-18(4)_, 8-9-17) SDP202100077 A MINOR SITE PLAN AMENDMENT TO "PREVIOUS SDP20200006OR DS TAVERN ALBEMARLE COUNTY, VIRGINIA LINEAGE JOB #19066 INDEX OF SHEETS DESCRIPTION SHEET NO. r. M:141 ,i c �-- All s 1' r� low '`. lip �• K VICINITY MAP (SCALE 1:2000) FIRM INFO: Lineage Architects, P.C. P.O. Box 991 SITE 98 Lee Highway Verona, VA 24482 Phone: (540) 248-3771 Fax: (540) 248-1628 Email: info@lineagearch.com ENGINEER -LSEAL: If parv- TITLE SHEET C.01 N GENERAL NOTES C-02 EXISTING CONDITIONS C-03 EXISTING ZONING, SETBACKS, AND EASEMENTS . _ C-03 A OVERALL SITE PLAN _ _ C-04 LANDSCAPING PLAN (BY OTHERS) C-04 A SANITARY SEWER PLAN . C-04 B SITE LIGHTING PLAN _ C-04 C SANITARY FORCE MAIN PROFILE _ _ _ _ _ C-04 D PKATA MN 1 101 B , M d M_ mall 0 ♦' ` — sm IL v�ivsj i...favv yvr� Anal A,...__ HANDICAP PARKING LAYOUT & CONSTRUCTION DETAILS. C-06 A LANDSCAPING DETAILS C-07 GENERAL PROPERTY INFORMATION PROPOSED USE: BUILDING ADDITION FOR 3100 S.F. OF OFFICE SPACE. 9 ADDITIONAL PARKING SPACES. OWNER: IVY ROAD RE LLC. 1. TAX MAP: 059000000015AO 2. ZONING: a. PROPERTY IS SPLIT -ZONE C-1 COMMERCIAL AND RA RURAL AREA b. PROPERTY IS LOCATED WITHIN THE ENTRANCE CORRIDOR OVERLAY DISTRICT c. PROPERTY IS SUBJECT TO PROFFERS PER ZMA198400026 d. PROPERTY HAS CRITICAL STEEP SLOPES 3. MAGISTERIAL DISTRICT: SAMUEL MILLER DISTRICT 4. WATERSHED: SOUTH FORK RIVANNA WATER SUPPLY WATERSHED 5. THE PROPERTY IS NOT LOCATED WITHIN THE ACSA JURISDICTIONAL AREA AND DOES NOT HAVE ACCESS TO PUBLIC WATER/SEWER. 6. DATUM REFERENCE: BENCHMARK AXLE-1534.901 PROPERTY INFORMATION FOR TMP 59-15A1 OWNER: IVY ROAD RE LLC. DESIGNER: LINEAGE ARCHITECTS, P.C. ATTN: JON GARBER P.O. BOX 991 98 LEE HIGHWAY VERONA, VIRGINIA 24482 PHONE: (540) 248-3771 DEVELOPER: 704 CAPITAL, LLC 'cne AR'emarie Count,/ r . ;'.:unity Dr ilIII _ fl p Z0Z j 00077 SICAATURE PANEL: DEPARTMENT OF COMMUNITY DEVELOPMENT; PLANNING i ZONING ENGINEERING INSPECTIONS ARCHITECTURAL REVIEA BOARD DEPARTMENT OF FIRE AND RE5CUE ALBEMARLE COUNTRY SERVICE AUTHORITY VIRGINIA DEPARTMENT OF TRANSPORTATION HEALTH DEPARTMENT r� W W � 1 4 h� U W o Feel `� U ti rf� > , V 7 COMMENTS J/10/2022 ---------- 6 COMMENTS 11/5/2021 APPROVAL DATE • j2.fti 1f1L2 ------------------ ----------------------- ---------------- ------ --- --- ---------- -___ -------- --- ------------- --- 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISION/ISSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: TITLE SHEET DRAWING NUMBER: 1. TAX MAP: 059000000015A1 2. DB REFERENCE: 5123/91 GENERAL NOTES: �I 11 ANY DISCREPANCIES FOUND BETWEEN THE DRAWINGS AND SPECIFICATIONS, AND SITE CONDITIONS OR ANY INCONSISTENCIES OR AMBIGUITIES IN DRAWINGS OR SPECIFICATIONS SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER IN WRITING WHO SHALL PROMPTLY ADDRESS SUCH INCONSISTENCIES OR AMBIGUITIES IN WRITING. WORK DONE BY THE CONTRACTOR AFTER HIS DISCOVERY OF SUCH DISCREPANCIES, INCONSISTENCIES, OR AMBIGUITIES WITHOUT CLARIFICATION FROM THE ENGINEER OF RECORD, SHALL BE DONE AT THE CONTRACTOR'S RISK. n 2) THE LOCATION OF EXISTING UTILITIES AS SHOWN IS APPROXIMATE ONLY, THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL PUBLIC OR PRIVATE UTILITIES WHICH LIE IN OR ADJACENT TO THE CONSTRUCTION SITE. THE r CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING, AT HIS EXPENSE, ALL s EXISTING UTILITIES DAMAGED DURING CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE TEST PITS AT ALL LOCATIONS WHERE PROPOSED CONSTRUCTION T CROSSES EXISTING WATER, GAS AND FIBER OPTIC LINES. 0 0 3) THREE BUSINESS DAYS PRIOR TO ANY EXCAVATION CALL MISS UTILITY. 0 4) ALL CONSTRUCTION IS TO BE IN ACCORDANCE WITH LOCAL AUTHORITY 0 C 5) WORK IN THIS PROJECT SHALL CONFORM TO THE LATEST EDITIONS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT) ROAD AND BRIDGE SPECIFICATIONS, THE VDOT ROAD AND BRIDGE STANDARDS, THE VIRGINIA L EROSION AND SEDIMENT CONTROL REGULATIONS AND APPLICABLE STANDARDS OF ALBEMARLE COUNTY. IN THE EVENT OF CONFLICT BETWEEN ANY OF THESE STANDARDS, SPECIFICATIONS OR PLANS, THE MOST STRINGENT SHALL GOVERN. ALL UTILITIES TO BE DEDICATED TO THE ALBEMARLE COUNTY MUNICIPAL WATER SYSTEM SHALL BE CONSTRUCTED AND TESTED TO CONFORM TO COMMONWEALTH OF VIRGINIA/ STATE BOARD OF HEALTH WATERWORKS AND/OR SEWERAGE REGULATIONS AND THE ALBEMARLE COUNTY DESIGN AND CONSTRUCTION STANDARDS MANUAL. 6) DRAINAGE IMPROVEMENTS SHALL BE INSTALLED IN ACCORDANCE WITH 3 STANDARDS AND SPECIFICATIONS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION. a v 7) INSTALLATION OF CONCRETE STORM PIPE SHALL COMPLY WITH VDOT STANDARD DRAWING PB-1. 0 0 8) ALL RIGID PIPE BEDDING (CONCRETE, CEMENT LINED DUCTILE IRON PIPE, ETC.) L SHALL BE CLASS C, UNLESS NOTED OTHERWISE ON THE PLANS. 0 5 3 9) ALL UNDERGROUND FACILITIES LOCATED WITHIN THE VDOT RIGHTS -OF -WAY SHALL BE INSTALLED PRIOR TO THE PLACEMENT OF ANY PART OF THE PAVEMENT STRUCTURE. 3 0 10) ALL MATERIALS USED FOR FILL OR BACK -FILL SHALL BE FREE OF WOOD, ROOTS, ROCKS, BOULDERS OR ANY OTHER NON -COMPACTIBLE SOIL TYPE MATERIAL. UNSATISFACTORY MATERIALS ALSO INCLUDE MAN-MADE FILLS AND a REFUSE DEBRIS DERIVED FROM ANY SOURCE. 0 11) SATISFACTORY MATERIAL FOR USE AS FILL FOR PUBLIC STREETS INCLUDE CLASSIFIED IN ASTM D-2487 AS GW, GP, GM, GC, SW, SP, SM, SC, ML, AND CL GROUPS. THE MOISTURE CONTENT SHALL BE CONTROLLED WITHIN PLUS OR MINUS 2 PERCENTAGE POINTS OF OPTIMUM TO FACILITATE COMPACTION. GENERALLY, UNSATISFACTORY MATERIALS INCLUDE MATERIALS CLASSIFIED IN ASTM D-2487 AS PT, CH, MH, OL, OH AND ANY SOIL TOO WET TO FACILITATE COMPACTION. CH AND MH SOILS MAY BE USED SUBJECT TO RESULTS OF THE GEOTECHNICAL REPORT AND UPON APPROVAL OF THE SUPERVISING ENGINEER. SOILS SHALL HAVE A MINIMUM DRY DENSITY OF 91 92 LB/CU. FT. PER ASTM D-698 AND SHALL HAVE A PLASTICITY INDEX LESS THAN 17. 12) MATERIALS USED TO CONSTRUCT EMBANKMENTS FOR ANY PURPOSE, BACK - FILL AROUND DRAINAGE STRUCTURES OR IN UTILITY TRENCHES OR ANY OTHER DEPRESSION REQUIRING FILL OR BACK -FILL SHALL BE COMPACTED TO 95% OF MAXIMUM DENSITY AS DETERMINED BY THE STANDARD PROCTOR TEST AS SET OUT IN ASTM STANDARD D-698. THE CONTRACTOR SHALL, PRIOR TO ANY OPERATIONS INVOLVING FILLING OR BACKFILLING, SUBMIT THE RESULTS OF THE PROCTOR TEST TOGETHER WITH A CERTIFICATION THAT THE SOIL TESTED IS REPRESENTATIVE OF THE MATERIALS TO BE USED ON THE PROJECT. TESTS SHALL BE CONDUCTED BY A CERTIFIED MATERIALS TESTING LABORATORY AND THE CERTIFICATIONS MADE BY A LICENSED PROFESSIONAL ENGINEER REPRESENTING THE LABORATORY. 13) COMPACTION OF FILL MATERIAL UNDER BUILDING SLABS SHALL BE BASED UPON T RECOMMENDATIONS OF SOILS ENGINEER AFTER COMPLETION OF STANDARD PROCTOR IV CL TEST AND SHALL MEET BEARING REQUIREMENTS OF ARCHITECT FOR BUILDINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING. 0 14) EMBANKMENT FILL AND TRENCH BACK -FILL SHALL BE PLACED IN LIFTS AT A MAXIMUM UNCOMPACTED DEPTH OF 8-INCHES AND 6-INCHES, RESPECTIVELY. al DENSITY TESTS SHALL BE CONDUCTED AT THE FOLLOWING MINIMUM FREQUENCIES: 3 (A) EMBANKMENTS FOR ROADS, STREETS, DAMS, ETC,: a ONE TEST PER LIFT PER 10,000 SQUARE FEET OF LIFT. a (B) BACK -FILL AROUND STRUCTURES AND IN TRENCHES: ONE TEST PER LIFT PER 500 LINEAL FEET OF TRENCH. V) 15) COMPACTION TESTS FOR STREET PAVEMENT STRUCTURE SHALL BE MADE IN CUT 0 AND FILL AREAS AT THE FOLLOWING MINIMUM FREQUENCIES: 0 (A) SUB -GRADE: ONE TEST PER LANE PER 500 LINEAL FEET. (B) STONE -BASE: ONE TEST PER LANE PER 6" COMPACTED LIFT PFR 5flfl I INFAI FFFT U i (C) HOT ASPHALTIC CONCRETE: ONE TEST PER LANE PER LIFT PER 500 LINEAL FEET, J ABREVIATIONS: ARCH. ARCHITECT 16) ALL EXCAVATIONS, INCLUDING TRENCHES, SHALL BE KEPT DRY TO PROTECT C/L OR C L CENTERLINE THEIR INTEGRITY. C/OUT OR C/O CLEAN OUT CONC. CONCRETE 17) TEST RESULTS SHALL BE SUBMITTED TO THE SUPERVISING ENGINEER. FAILURE TO CONDUCT CG CURB & GUTTER DENSITY TESTS SHALL BE CAUSE FOR NON -ACCEPTANCE OF THE FACILITY, TESTS DIA. DIAMETER SHALL BE CONDUCTED AT THE SOLE COST OF THE DEVELOPER OR HIS AGENT. E.P. EDGE OF PAVEMENT EL. ELEVATION 18) NOT USED. ESMT. EASEMENT EW EXISTING WATER 19) NOT USED. EX. EXISTING F.E. FOUNDATION ELEVATION 20) NOT USED, F.E.S. FLARED END SECTION F.F.E. FINISHED FLOOR ELEVATION 21) INSPECTORS HAVE FULL AUTHORITY TO REJECT FILL OR BACKFILL MATERIALS, F.H. or F/HYD FIRE HYDRANT REQUIRE UNDERCUTTING OR SUBGRADE STABILIZATION, REQUIRE PROVISIONS FOR SUB- F/L FIRE LINE DRAINAGE, OR REQUIRE OTHER MEASURES WHICH AFFECT THE INTEGRITY OF ROAD AND F.W. TOP OF FOUNDATION WALL UTILITY CONSTRUCTION. FAILURE TO COMPLY WITH INSPECTOR'S DIRECTIVES SHALL BE G.V. GATE VALVE CAUSE FOR NON -ACCEPTANCE OF THE FACILITY, HORIZ. HORIZONTAL INV. INVERT 22) TRAFFIC CONTROL ON PUBLIC STREETS SHALL BE IN CONFORMANCE WITH THE MANUAL IRS IRON ROD SET OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). LAT. LATERAL LT. LEFT 23) A PRECONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE ISSUANCE OF THE LAND M/H MANHOLE DISTURBING PERMIT, THE CONTRACTOR SHALL ARRANGE THE MEETING WITH THE MIN, MINIMUM COUNTY ENGINEER. ALBEMARLE COUNTY PUBLIC UTILITIES INSPECTOR, REPRESENTING NE NORTH EAST WATER INTERESTS, SHALL ALSO ATTEND. ATTENDANCE SHALL BE COORDINATED THROUGH NW NORTH WEST THE OFFICE OF THE COUNTY ENGINEER. P.C, POINT OF CURVEP,I, POINT OF INTERSECTION 24) RETAINING WALLS GREATER THAN TIN HEIGHT REQUIRE A SEPARATE BUILDING PERMIT. WALLS P.T. POINT OF TANGENT EXCEEDING 4' IN HEIGHT REQUIRE A STAMPED ENGINEERING DESIGN ALSO. WALLS REQUIRE PVC POINT OF VERTICAL CURVE INSPECTIONS AS OUTLINED IN THE USBC, PVI POINT OF VERTICAL INTERSECTIONPVT POINT OF VERTICAL TANGENT 25) ACCESSIBLE PARKING SPACES, ACCESS AISLES, AND ACCESSIBLE ROUTES SHALL BE INSTALLED IN PVMT. PAVEMENT ACCORDANCE WITH ICC ANSI Al 17.1-09 AND THE 2015 VIRGINIA CONSTRUCTION CODE, R RADIUS R.D. ROOF DRAIN 26) BUILDING OR STRUCTURES BUILT BEFORE JANUARY 1,1985 MUST HAVE AN ASBESTOS SURVEY RT. RIGHT PERFORMED IN ORDER TO APPLY FOR A PERMIT. ASBESTOS REMOVAL PERMITS ARE REQUIRED SAN. SANITARY SEWER IF POSITIVE FOR SUCH FROM ALBEMARLE COUNTY AND VDOLI. CONTACT VDOLI FOR ADDITIONAL SEW, or SSEW. SEWER REQUIREMENTS AND PERMITS FOR DEMOLITION PROJECTS. STD, STANDARD STM. SEW. STORM SEWER 27) ALL ROOF DRAINS SHALL DISCHARGE IN A MANNER NOT TO CAUSE A PUBLIC NUISANCE AND NOT SE SOUTH EAST OVER SIDEWALKS. SW SOUTH WESTsm SIDEWALK 28) ALL HANDICAP PARKING SPACES AND ACCESS ISLES SHALL COMPLY WITH ADA STANDARDS OF S.F. SQUARE FEET ACCESSIBILITY. ACCESSIBLE PARKING SPACES AND ACCESS ISLES SHALL NOT HAVE A SURFACE STR, STRUCTURE SLOPE GREATER 1:48. ACCESS ISLES SHALL BE AT THE SAME LEVEL AS THE PARKING SPACE THEY T'B' TOP OF BANK SERVE. SEE SHEET C-05 FOR SPOT ELEVATIONS DETAILING CROSS SLOPES FOR ACCESSIBLE T/C TOP OF CURB TIP TOP OF GRAVEL PAVEMENT EXISTING ROADS ROAD CENTERLINE SIDEWALKS CONCRETE PAVEMENT GRAVEL SURFACE BUILDINGS FENCE DECIDUOUS TREE CONIFEROUS TREE CONIFEROUS SHRUB st ST STORM WATER LINE - - - PROPERTY LINE i STORM SEWER - - 2900 - - - - 2900 - - INDEX CONTOUR - - - 2898 - - - - - - 2896 - - - INTERMEDIATE CONTOUR 2876.3 x 2893.66 _1_x SPOT ELEVATION LIMITS OF CLEARING AND/OR GRADING PARKING SPACES AND ADJACENT ACCESS ISLES. SEE SHEET C-06 FOR DETAIL OF ACCESSIBLE TPD WATER SERVICE AND METER TRIPS PER DAY SIGNAGE. U/G UNDERGROUND VERT. VERTICAL -• SANITARY SEWER LATERAL AND CLEANOUT W/L WATERLINE Ss SS SANITARY SEWER LINE X-ING CROSSING one ❑HE OVERHEAD ELECTRIC LINE uge UGE UNDERGROUND ELECTRIC LINE oht ❑HT OVERHEAD TELECOM LINE VDOT General Notes ugt UGT UNDERGROUND TELECOM LINE V1. All work on this project shall conform to the current editions of and latest revisions to the Virginia Department of Transportation (VDOT) Road and Bridge Specifications and Standards, the Virginia Erosion and Sediment Control Regulations, and any other applicable state, federal or local regulations, In case of a discrepancy or conflict between the Standards or Specifications and Regulations, the most stringent shall govern. w W WATER LINE V2. All construction shall comply with the latest U.S. Department of Labor, Occupational Safety and Health Administration (OSHA), and Virginia Occupational Safety & Health (VOSH) Rules and Regulations. VDOT General Notes (Continued) gas GAS GAS LINE V3. When working within VDOT right-of-way, all traffic control, whether permanent or temporary, shall be in accordance with the current edition of VDOT's Work Area Protection Manual. A transportation management plan needs to be submitted for approval and land use permit issued prior to any execution of work within the VDOT right of way. V17. The installation of any entrances and mailboxes within any dedicated street right-of-way shall meet VDOT minimum design standards and is the responsibility of the developer. V4 The developer shall be responsible for relocating, at his expense, any and all utilities, including traffic signal poles, junction boxes, controllers, etc,, owned by VDOT or private l public utility companies, It is the sole responsibility of the V18. Prior to VDOT acceptance of any streets, all requiredstreet s'gna e and/or pavementmarkings shall be installed by developer in accordance with the Manual On Uniform Traffic developer to locate and identify utilityfacilities or items that may be in conflict with the proposed construction activity. VDOT approval of these Plans does not indemnify the developer from this responsibility. Control Devices. V5. Design features relating to field construction, regulations, and control or safety of traffic may be subject to change as deemed necessary by VDOT. Any additional expense incurred as a result of any field revision shall be the responsibility V19. The developer shall provide the VDOT Land Development Office with a list of all material sources prior to the start of construction, Copies of all invoices for materials utilized within any of the developer. dedicated street right-of-way must be provided to the local VDOT Land Development Office prior to acceptance of the work.'Unit and total prices may be obscured, V6. If required by the local VDOT Land Development Office, a pre -construction conference shall be arranged and held by the engineer and/or developer with the attendance of the contractor (s), various County agencies, utility companies and V20. Aggregate base and subbase materials shall be placed on subgrade by means of a mechanical spreader. Density will be determined using the density control strip in accordance with VDOT prior to initiation of work. Section 304 of the VDOT Road and Bridge Specifications and VTM-10. A certified compaction technician shall perform these tests. Certified copies of test reports shall be submitted to V7. The contractor shall notify the local VDOT Land Development Office when work is to begin or cease for any undetermined length of time. VDOT requires and shall receive 48 hours advance notice prior to any required or requested VDOT daily, unless specified otherwise. In addition to checking stone depths, a VDOT representative shall be notified and given the opportunity to be present during the construction and testing of the density control strip. inspection. V8. The contractor shall notify the Traffic Operations Center at (540) 332-9500 for any traffic control plan that impacts a VDOT maintained Interstate or Primary roadway to provide notification of the installation and removal of the work zone. V21. Asphalt concrete pavements shall be laced i accordance with Section 315 of the VDOT Road and Bridge Specifications, Density shall be determined using the density control strip as ph p p n h n g p y n g y p specified in Section 315 and VTM-76. A certified compaction technician shall perform these tests. Certified copies of test reports shall be submitted to VDOT daily, unless specified V9. The contractor shall be responsible for maintaining a VDOT permitted temporary construction entrances m accordance with Section 3,02 of the Virginia Erosion and Sediment Control Handbook. Furthermore, access to other properties P 9 p P Y O� 9 P P otherwise, A VDOT representative shall be notified and given the opportunity to be present during the construction and testing of the control strip. affected by this project shall be maintained through construction. V22. In accordance with Section 302.03, the foundations for pipe culverts thirty-six (36) inches and larger shall be explored below the bottom of the excavation to determine the type and V10. Contractor shall ensure adequate drainage is achieved and maintained on the site during and at the end of construction, condition of the foundation. The contractor shall report findings of foundation exploration to the engineer and VDOT for approval prior to placing pipe. Foundation designs shall comply with VDOT Road and Bridge Standard PB-1. Where soft, yielding, or otherwise unsuitable foundation is encountered, the foundation design and/or need for foundation stabilization shall V11. All water and sewer lines within existingor proposed VDOT right-of-way shall have a minimum thirty-six 36 inches cover and when possible shall be installed under roadway drainage facilities at conflict points. P P g Y() P Y g be determined by the engineer and approved by VDOT, V12. Any unusual subsurface conditions (e.g,, unsuitable soils, springs, sinkholes, voids, caves, etc,) encountered during the course of construction shall be immediately brought to the attention of the engineer and VDOT, Work shall cease in V23. VDOT Standard Guardrail shall be installed where warranted and/or as proposed on these plans in accordance with VDOT's installation criteria. Final approval of the guardrail layout to be given by VDOT after grading is mostly complete. that vicinity until an adequate design can be determined by the engineer and approved by VDOT. V13. All fill areas, borrow material and undercut areas shall be inspected and approved b a VDOT representative prior to placement of fill. A VDOT representative shall be resent to insure the soil sample(s)obtained for CBR's is P PP Y P P P P P V24. Approval of these plans shall expire five (5) years from the date of the approval letter. representative of the location. When soil samples are submitted to private laboratories for testing, the samples shall be clearly identified and labeled as belonging to a project to be accepted by VDOT and that testing shall be performed in V25. VDOT Standard CG-12 Curb Ramps shall be installed where indicated on these plans and/or as specified by VDOT. accordance with all applicable VDOT standards and procedures, r h h lift thicknesses, density n moisture requirements specified in h rr n VDOT Road an Bridge V14. All roadway fill, base, subgrade material, and backfill in utility/storm sewer trenches shall be compacted in accordance with the i t t c esses, de s ty and as spec ed t e cu e t d 9e V26. The foundations for all box culverts shall be investigated by means of exploratory borings advanced below proposed foundation elevation to determine the type and condition of the foundation. The contractor shall submit copies of borehole logs and report findings of foundation exploration to the engineer and VDOT for approval prior to constructing box. Specifications. Certified copies of test reports shall be submitted to VDOT daily, unless specified otherwise. Foundation designs shall comply with VDOT Road and Bridge Standard PB-1. Contrary to the Standard, where rock is encountered and cast -in -place box is proposed, the thickness of V15. VDOT Standard CD and LID underdrains shall be installed where indicated on these plans and/or as specified by VDOT. bedding shall be six (6) inches. Where soft, yielding, or otherwise unsuitable foundation is encountered, the foundation design and/or need for foundation stabilization shall be V16. A post installation visual/video camera inspection shall be conducted b the Contractor on all pipes identified on the plans as storm sewer pipe and a select number of pipe culverts. For pipe culverts, a minimum of one pipe installation P P Y P�P P P P P•P P�P P�P determined by the engineer and approved by VDOT, for each size of each material type will be inspected or ten percent of the total amount for each size and material type summarized. All pipe installations on the plans not identified as storm sewer pipe shall be considered as culvert pipe for inspection purposes. Additional testing may be required as directed by the Area Land Use Engineer or their representative. FIRM INFO: Lineage Architects, P.C, P.O. Box 991 98 Lee Highway Verona, VA 24482 Phone: (540) 248-3771 Fax: (540) 248-1628 Email: info@Iineagearch.com ENGINEER NAME/SEAL: op � U JONATW F, GARBER > No, 038568 �01 /10 /2 2�0 �`S111pNAL E��1 w a iJ o w U r U v, 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: GENERAL NOTES DRAWING NUMBER: C-02 c k>. +(�'�' \ 34" TULIP POPLAR \ I IVY ROAD \ US ROUTE 250 DEMOLISH AND REMOVE — CRAPE MYRTLE x3 \a \ ADO i _ 80.00 R.O.W. \ Q DOGWOOD x2 v DOGWOOD ARBORVITAE SCREEN s \ APPROX. LOCATION $9 — =�cT�Q� d8 EVERGREEN MAGNOLIASEPTIC LINE TYP. 3 ° a ° 0 ° 3 TM 59-16A SEPTIC LID O IVY HILL GARDENS, LLC DEMOLISH AND REMOVE \I�` +' i\�`' CLEANOUT• 14 WILLOW OAK > MIXED DECIDUOUS BED \�\I �I\� I �+ DB 5002/71 + + 1DEMOLISH AND REMOV \ \\I�`+%':'\ / �' DECIDUOUS MAGNOLI �` j \�. 7u7 ;' DEMOLISH AND l DEMOLISH AND REMOVE I14 RURAL AREA \\II 1��\11,� �-'� o DEMOLISH AND REMOVE REMOVE BIRCH I SHRUBS x4�C, POWER POLE MULTI -FAMILY RESIDENTIAL \I+I DEMOLISH AND REMOVE' _ Y +� DOGWOOD x3 DEMOLISH AND REMOVE / '�i �� ` 1 DEMOLISH AND REMOVE f , \\\ CONCRETE PATH �\ >i + S� f?_ + �, �, FENCE x2 +` ° ���+,,\� \ �• / �, , DEMOLISH AND REMOVE + t\�` �/ \ \�/�/ / �, + \h�,, f/ OVERHEAD ELECTRIC LINE t�� DECIDUOUS MAGNOLIA �\ �\�/DEMOLISH AND REMOVE ABANDON EXISTING SEPTIC + �� �✓i tom,+1\`` / WOOD PATH EDGE LINE PAST NEW CIO + / \ GRAVEL DRIVEWAY \ ~ r \�Y +Il\\ 3846.50 SF i ONE STORY HOUSE l DEMOLISH AND REMOVE \I,+�tFl\�`� DOOR527.91' / ARBORVITAE SCREEN \�\ /+'.'fit\�1303 SF I ROSE OF SHARON x6 ,r\I\� DEMOLISH AND REMOVE HEMLOCK ROW—\v\tt\�` \ /. Q I BRICK PATH ------------------- 3i DEMOLISH AND REMOVE DEMOLI�- I , \� +0 REDCEDAR FLAG POD \t '£tl\� /�\IFj>+�tV\� BRICK �\tCt` PATIO ; 2 STORY HISTORIC TAVERN ROOFTOP 551.7' ?� / BRICK RETAINING WALL �� 1612 SF _ oFck rG 1 ° +�&t\/&r\ MAX HEIGHT: O� poRc i�l�°�+�i / BENCHMARK -�7\I + POND / \^ \ N�°+ AXLE . • • • • \ / \\ / o / / f �\ 1 STORY BLDG c ELEVATION '/\� . . . . ' DEMOLISH AND REMOVE DOOR525.8' �` DEMOLISH AND a 534.90' d,° ROOFTOP 542.9' .,REMOVE DOGWOOD { EXISTING PATIO 230 SF + �s a / DEMOLISH AND REMOVE EXISTING PORCH "I STORY HOUSE � � Y �o , \ PER ARCHITECTURAL PLANS FF 526.94' / \ RIDGELINE 538.25' WOODED SLOPE . . . . . . . . . . . . . _ 17?4 SF 3 MIX OF DECIDUOUS. e/Rocq�� \� �0�it 4� 1-- > AND EVERGREEN �STO E ETAI ING ALL / 5V0' N R N W / p- CRITICAL SLOPES ' • MAX HEIGHT: 3.00' DEM LISH AND REMOVE rr / /. POWER POLE -'UT TY POLE \ �. BLDG 4o.00 T ' 1 DEMOLISH AND REMOVE EXISTING HOUSE . . . PER ARCHITECTURAL PLANS . . t. r DEMOLISH AND REMOVE . . . . . . . . . 54 /. OVERHEAD ELECTRIC LINE . . . . . . . . . . . ..� . 500 '1Vi UTILITY POLE 1 . . . . . / . CRITICAL SLOPES + U . . . . . . . . . . . . . .l .. . . . . . . . . D .. .. .'. .. .. ..'..'..4. .' . .'.... / / I . . . . . . . . . . / . _.-r• . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ° BLACK WALNUT \! IIII BACK' W. ALNUTx. . . . . . . . . . . . . . . . ----- L .................. \ /\ I�a- _ . . . . . . . \\`,\ \\\ \\\ \, \\ <V \ `\I I 1 -� \ 11 `I 1 +'I,• ''ll ''1.IZ >7 . ' . ' . • . ' . ' . ' . . ' . ' . ' . ' . \\ `\ \\ \ \\\\\`, ' - ; • •`1 •'1,' \`,• '� '1 'I II \`\ TM 59-15A ° . • ; I II y . . . . . . . . . IVY ROAD RE, LLCM DB 5123/91 + �.. RURAL AREA / C1 COMMERCIAL " .. Inst 201800013717 �;..........'I + �r� �. ., . .1` . ' . 'll . I . II fill i ,' 1,'. . JAPANESE MAPLE x2 j FEMA Flood Zone X 51003CO265D, 2/4/05 sti ........ . . . . . . .,, .. .j. Samuel Miller Magisterial District . !. 1. • . !;, ! '1 I.I.1�; I';1 . ``.;. \ • I';i i ; ' I-Iii --------- BLDG CoNC ; , WOODED SLOPEo PAD o ;•I •j I { MIX OF DECIDUOUS n / AND EVERGREEN ' II T \ O CL �,---------------- I °3QSQ•'3'Z\ / N69 Q� H/8g4 t 1 ill 'i i1 ;I I III g' zo Ln Q, 1• ( •, ' 1 I I ,' ry N QQ //�� ^ 5,3 / T M 5 9-1 5 B N87° 08'33"W 86.82' N / HALLAM ROTH x T DB 4263/729 TM 59-15 �o RURAL AREA JERRY D BENINATE l SINGLE FAMILY RESIDENTIAL / DB 1654/396 U U 1 ° c R77.35' GENERAL NOTES: 1. CURRENT FIELD SURVEY RECORDED BY LINEAGE ARCHITECTS, PC ON OCTOBER 28, 2019 AND JULY 7, 2021. 2. BULK TOPOGRAPHY SHOT IN FIELD BY LINEAGE ARCHITECTS, PC (SEE NOTE 1). SEPTIC TOPOGRAPHY BASED ON COUNTY GIS. 3. THE SITE IS DETERMINED TO BE LOCATED WITHIN THE IVY CREEK RESERVOIR WATERSHED, 4. THE SITE IS SPLIT -ZONED C1 COMMERCIAL AND RA RURAL AREA. 5. THE SITE IS LOCATED IN FEMA FLOODPLAIN ZONE X; THE SITE IS DETERMINED TO BE OUTSIDE THE 100 YEAR FLOOD PLAIN. FIRM MAP NUMBER: 510 03C 0265 D. EFFECTIVE DATE: FEB. 4, 2005 6. NO STRUCTURE, EITHER EXISTING OR PROPOSED, EXCEEDS 65 FEET IN HEIGHT PER SECTION 21.4 OF THE ALBEMARLE COUNTY ZONING CODE. 6, BENCHMARKS AND ELEVATIONS ARE RELATIVE TO VIRGINIA NORTH ZONE 4501. \ 7. ALL PLANT MATERIAL IS UNDER 6" CALIPER UNLESS OTHERWISE s, NOTED. %s 8. ALL TREES NOT EXPLICITLY SHOWN FOR DEMOLITION SHALL BE q �9.° 4, \ PRESERVED. 9. ALL DEMOLISHED MATERIAL IS TO BE REMOVED TO LANDFILL. 0 o,� °1y op2F,3 EASEMENTS OF RECORD: (EASEMENTS AS KNOWN OR DISCLOSED, NO TITLE REPORT FURNISHED, UTILITY POLE I \ ADDITIONAL EASEMENTS OR UTILITIES MAY OR MAY NOT EXIST.) DOGWOOD / ,L- Zo"WILLOW OAK VIRGINIA ELECTRIC AND POWER COMPANY EASEMENTS: s ' A`Tci REMOVE .......... DB 307/183 POLE LINE EASEMENT PARALLEL TO RT. 250, NO WIDTH GIVEN. + Q + \ -NOT PLOTTED RURALAREA RESIDENTIAL -MOBILE HOME \ \\ DEMOLISH AND REMOVE \'`, \ DB 316/562 POLE LINE EASEMENT PERPENDICULAR TO RT. 250, NO WIDTH LAURELS \`o° GIVEN. -NOT PLOTTED DEMOLISH AND REMOVE DOGWOOD s ELECTRIC EASEMENT RESERVATIONS: \ DB 263/230 RESERVATION FOR AN EASEMENT FOR POWERLINE CROSSING \ \ p� :: ' PROPERTY. NO WIDTH GIVEN. LOCATION NOT SPECIFIED, NOT 416),0•� PLOTTABLE. py�.. .... ' .. DB 263/440 RESERVATION FOR AN EASEMENT FOR POWERLINE CROSSING , ' , ' , ' , ' , ' , PROPERTY. NO WIDTH GIVEN. LOCATION NOT SPECIFIED, NOT PLOTTABLE. TM 59-15AT', I ...... • CRAPEMYRTLE x3 IVY ROAD RE, LLC` I. VIRGINIA TELEPHONE AND TELEGRAPH EASEMENTS: \.. DB 5123/91 I ..'..'.'.'.'..'....'.'.. . DB 338/415 POLE LINE EASEMENT, WIN WIDTH CENTERED ON WIRES AS Cl"C,OMMERCIAL I BENCHMARK CONSTRUCTED. NO LOCATION SPECIFIED. NOT PLOTTED. IRON PINLEVATIDB 338/424 POLE LINE EASEMENT, 20' IN WIDTH CENTERED ON WIRES AS LAND USE UNASSIGNED \ \ E1523.31oN CONSTRUCTED. NO LOCATION SPECIFIED, NOT PLOTTED. , s WATERLINE EASEMENT: \ \ \ \ DB 357/219 RIGHTS TO A WELL AND WATERLINE, IN EXCHANGE FOR A CRAPEMYRTLE x2 RELEASE TO RIGHTS TO A SPRING, / ACCESS EASEMENT: \ \41 1 DB 263/440 A 20' WIDTH EASEMENT FFOR ACCESS, OVER THE "OLD D.S. ROAD", SHOWN HEREON ON THE WESTERN SIDE OF THE PROPERTY. �a DB 4491/396 A SHARED DRIVEWAY EASEMENT SHOWN HEREON. ------------- ------------- ----------- AREA OF RESTRICTED USE: DB 263/230 AREA DEFINED TO BE KEPT FREE OF BUILDING OR PENS OF ANY KIND; TO BE USED ONLY FOR GARDENS AND PASTURE (EXCEPTING FOR HOGS OR GOATS), SHOWN HEREON. a g L44 544 S40 SIGHT LINE AT .6' HEIGHT— 0 536 36 — Si Hi LINe A73.6'HEIGH7 EOFI RO 532 — MISTING 532 526 E 526 524 524 520 526 +I p 4 4 b SIGHT DISTANCE PROFILE AT IVY ROAD SCALE: 1 "=200' EXISTING CONDITIONS AND DEMOLITION PLAN SCALE: 1"=20' GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. FIRM INFO: Lineage Architects, P.C. P,O. Box 991 98 Lee Highway Verona, VA 24482 Phone: (540) 248-3771 Fax: (540)248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: LTH OF� P. ;F� U JONATHAN F. GARBER > No. 038568 �t Ol /10/22� C I O a, 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/19/20 NO. REVISION/ISSUE DATE JOB NUMBER. 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: EXISTING CONDITIONS AND DEMOLITION PLAN DRAWING NUMBER: C-03 O T RIGHT-OF-WAY DB 263/440 / I I • i l l l f l l l l I l i l l l l l l l l a I I I I I I I I I I I I I I I I I I I I i l l l l l l I I I i l i l l l l l l l l I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ( I I I I I I I IRA ZO I l l l l l l l l l l l l i i I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I i l l l i l l l l l i ( I I I I I I I I I i i l l l l l l l I I I I I I I I I I I I I I I ' I I co �I 0 0 0I0 0 0 O C O 0 E E 0 �\vXX 9tf38�Y EXISTING 1 STORY 44HOUSE �y, p 1703 SF _ / �10C FFE 521.91 _ Tyco EXISTING BRICK—" a ` EXISTING 2 STORY 02� PATIO HISTORIC TAVERN 94 •^yQ — FFE 526.p NO 6 V '� PROP06E PROPOSED_ rsroav aoomoH 25TORY 195 SF EXI6T'i9LD0 iOR F�TADDITION— FFE53a9p r,p pP B795F FROM PATIO FFE: 525.9i FFE526.83— (REAR ENTRANCE) I EAT REAR NTRANCE) IN6TALL BRICK PATIO I I I I I I ( I I I I I I ( I I I ( I I I (( I i l l l I I I I I I I I I I I I ( I I I l l f I I i l )NING i i i l I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I i l l l ( I I I I I I I I AND L4N06CAPING •— DESIGN BY OTHER r BLDG - I�i l i I I l l l i l l l I I I I I I I I I I l l l l l l I I I I I l l l l l i l I I I I l \ \ • I l I I I I l l l I I I I I I I I I i I I l I I I I TO BE KIND: PASTURE KEPT TO "RESTRICTED FREE OF BE USED (EXCEPTING BUILDINGS ONLY FOR OB 2(31230 AREA" OR FOR GARDENS HOGS PENS OR GOATS) OF ANY AND I I I I l I I I l l l I I I i I I I I I l I I l I I I I I I I l I I I l l i I I i l I I i I i i I I l I I I I I I l I I I l l l I I l l I I l I l l I I l I I I I I i I I I l l l I I l l I I l I l l I I l I I I I I l I I I I l i l I I l l I I l I l l I I l I I I I I l I I I I l i l I I l l I I l I l l I I l I I I I I I I I I l l i i I l l I I l I l l I I l I I I I I I I I l l l l I l l I I i I l l I I l I I I I I l l l l I l l I I l I l l I I i I I � l l l l I l l I I l I l i I I l I I l l l I l l I I l I l l I I l I l l I l l I I l I l l I I l GRAPHIC SCALE 30 0 15 30 40 ( IN FEET ) 1 inch = 30 ft. 60 EXISTING ZONING AND EASEMENTS SCALE: 1 "=20' / CRITICAL SLOPES / �• 30 \�R yAR�SF r\ AFR4'0 \ GRAPHIC SCALE 0 15 30 40 ( IN FEET ) 1 inch = 30 ft. 60 1 EXISTING BUFFERS AND SETBACKS SCALE: 1 "= 20' FIRM INFO: Lineage Architects, P.C. P.O. Box 991 98 Lee Highway Verona, VA 24482 Phone: (540) 248-3771 Fax: (540)248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: TH p1^F U JONATHAN F. GARBER �11 No. 038568 01 /10 /2 2,4v -"n:sjoNAL E�ti a a W O U O F V1 z U 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISION/ISSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: EXISTING ZONING, SETBACKS, AND EASEMENTS DRAWING NUMBER: C-03 A � oAt V) D o 91 D Q1 0 v 0 N v a m N N C D a v v C c rn T i N 0 a L v C 0 v 0 PARKING CALCULATIONS TABLE AS PER 18-4.12.6 OFFICES, BUSINESS, ADMINISTRATIVE AND PROFESSIONAL (INCLUDING MEDICAL OFFICES BUT NOT DENTAL CLINICS) REQUIREMENT: 1 SPACE / 200 SF OF GROSS COMMERCIAL OFFICE SPACE WHERE GROSS COMMERCIAL OFFICE SPACE= 80% OF THE NET SF OF THE BUILDING FOOTPRINT OR AT THE REQUEST OF F m THE APPLICANT, THE ACTUAL NET OFFICE FLOOR AREA AS SHOWN ON Imo\ FLOOR PLANS SUBMITTED BY THE APPLICANT, DELINEATING THE ACTUAL 00 NET OFFICE FLOOR AREA, WHICH PLANS SHALL BE BINDING AS TO THE \ m MAXIMUM NET FLOOR AREA USED. / F "F NET SF OF OFFICES ONLY: 2,396 sf / INSTALL FLAGPOLE -\ F INSTALL 2"PVC 200 =11.95 = 12 ELECTRIC CONDUIT TOTAL SPACES REQUIRED = 12 (INCLUDING 1 H/C) / E, 2" PVC CONDUIT I TOTAL SPACES PROVIDED =12 (INCLUDING 1 H/C) IINSTALL STEEL EDGING ALONG - /�G,UCEDRIVE AND PARKING \ 10 V ` / � GRAVEL DRIVE � ���'� � YARD INLET TO, COLLECT � 6328.50 SF gyp' 9` OUTPUT FROM ROOF AND �7 � INSTALL STEPPING STONES E O�ODOO PER DETAIL 1/C-06 FOUNDATION DRAINS OF STRUCTURE, 4" YARD INLET TO 90° ELBOW HANDICAP PARKING AND ACCESS AISLE r! R3.00 INSTALL BRICK PAVERS GRADE: 524.15 . / SEE DETAIL 1/C-06; 50 PER DETAIL 3/C-06 INV. OUT: 620.77 E fi INSTALL ADA COMPLIANT GRAVEL GRID - X 1 \ C 580.' S1 PER DETAIL 2/C 06 2 / / 1 cO�f.O EXISTING 1 STORY 2.00 ' 440 \IIV7 fi • IQQ HOUSE v7 p, i , f / yQQ` 1303 SF 00_ B / 4.00 1 fi FFE 527.91 S. 0 ti' UCf E "RESERVED OWNER - , 8,00 A PARKING" SIGN E E INSTALL SCREENING FENCE ' Cte fi X / \�QQ�ZG0 EXIS PING BRICK II ST\ BRICK PAVERS 5.00 E 1` R HVAC SEE DETAILS 1 AND 21 C-04 A "'6.00_ \ \ PER DETAIL 3/C-06 . EXISTING 2 STORY E f HISTORIC TAVERN RI# U FFE 1526 94 C �€ ADA ACCESSIBLE PATH c� O� EMERGENCY ACCESS 4 C 1 STORY ADDITION DISTANCE - 87.00' O0 PR&OSED PROPOSED EXISTING 1 STOR ` I 2STORY 285SF BLDG 1 ADDITION FFE526.60 230SF HVAC K01 POND TO REMAIN 979 SF A FROM PATIO) FFE:525.87 10n (REAR ENTRANCE IN -GROUND PROPANE TANK FFE 526.83 ELEC 1g YARD INLET TO COLLECT 1Q0 " (AT REAR HVAC �\ / OUTPUT FROM ROOF AND�\1? \ ENTRANCE) r EXISTING STONE RETAINING WALL, TO REMAIN FOUNDATION DRAINS "A A 5 L Iti MAX HEIGHT: 3.00' OF STRUCTURE, 1p� "� AND LANDSCAPING. 8" BRONZE NYLOPLAST , / E/ DROP -IN GRATE TO c 8" NYLOPLAST TEE ¢ / CRITICAL SLOPES / TOP: 526.05 (5E�E °sw„G) AA_ / INV. OUT: 524.55 / EXISTING BIRD CAGE, TO REMAIN / c�F\ E l //b be,� 45° ELBOW S1 E BLDG ]INSTALL 8" PVC STORM PIPE n INSTALL 4" PVC 127.5V @ 1.3% TO 90° ELBOW TOP: 45° ELBOW / OUT: 1"PVC CONDUIT INV. OUT: / EMERGENCY AC EMERGENCY AC DISTANCE - 112 / 3" PVC CONDUIT 2" PVC CONDUIT 1 CRITICAL SLOPES GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. 8" PVC PIPE END INV. OUT: 520: ,, V� 2" PVC CONDUIT SHARED DRIVEWAY ACCESS EASEMENT (SEE SHEET C-03 A) INSTALL KNOX BOX CONTRACTORS TO COORDINATE WITH ONE ANOTHER OVERALL SITE PLAN SCALE: 1 "= 20' GENERAL NOTES: to l� 1. ALL RADII = F UNLESS NOTED OTHERWISE. 2. ARCHITECTURAL BUILDING DIMENSIONS SUPERSEDE BUILDING DIMENSIONS AS SHOWN ON THIS PLAN. 3. PAVEMENT AT ALL ENTRANCES SHALL MATCH THE EXISTING CROSS SECTION OF ROUTE 250. 4. THERE WILL BE NO CHANGE IN THE EXISTING POINT OF INGRESS TO, OR EGRESS FROM, THE SITE. 5. THE MAXIMUM IMPERVIOUS SURFACE AREA ONSITE IS 3100 SF( 0.07 ACRES). W 6. PROPOSED SITE USE IS COMMERCIAL OFFICE ONLY. THERE WILL BE NO RETAIL USE, EITHER GIFT, CRAFT, ANTIQUE SHOP, OR OTHERWISE. TOTAL ACREAGE OF PROPOSED USE = 0.06 ACRES Z W TOTAL NUMBER OF EMPLOYEES = 4 7. NO SITE LIGHTING IS PROPOSED FOR PARKING AREAS. 8. THERE ARE NO ADDITIONAL EASEMENTS PROPOSED FOR THE SITE. W 9. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE N ELIMINATED. 10. ALL ROOF DRAINS SHALL DISCHARGE IN A MANNER NOT TO CAUSE PUBLIC NUISANCE U AND NOT OVER SIDEWALKS. 11. ALL ACCESSIBLE PARKING SPACES AND ACCESS ISLES SHALL CONFORM WITH ADA DESIGN STANDARDS FOR ACCESSIBILITY. CROSS SLOPES OF ACCESSIBLE PARKING SPACES AND ADJACENT ACCESS ISLES SHALL NOT EXCEED 1:48. ACCESS ISLES SHALL FIRM INFO' BE AT THE SAME LEVEL AS THE PARKING SPACES THEY SERVE. Lineage Architects, P.C. 12. ORDINANCE 18-4.12.13(C): LOADING SPACE. THE LOW LEVEL OF ON -SITE STAFF AS WELL P.O. Box 991 98 Lee Highway AS THE INTENDED USE OF THE OFFICE AS A SPACE FOR MANAGING LOCAL ASSETS Verona, VA 24482 WILL NOT GENERATE THE SIZE OR QUANTITY OF DELIVERIES TO THE BUILDING SUCH Phone: (540) 248-3771 THAT A LOADING SPACE WOULD BE NECESSARY. THESE FACTS, IN COMBINATION WITH Fax: (540) 248-1628 THE OWNER'S INTENTION TO MAINTAIN THE HISTORIC CHARACTER OF THE SITE, LEAD Email: info@lineagearch.com TO THE REQUEST THAT THE LOADING SPACE REQUIREMENT BE WAIVED VIA 18-4.12.13(F). ENGINEER NAME/SEAL: 13. MAINTAIN 8" CLEARANCE ABOVE FINAL GRADE FOR ALL NON -MASONRY MATERIALS. FIRE FIGHTING INFORMATION. UJONATHAN F. GAMBER� No. 038568 1. AVAILABLE FLOW AT HYDRANT NO,12796 = 2796 GPM ���01 /10/22� �SjONAL ��G1 2. NEEDED FIRE FLOW -1500 GPM a. F =1.5 WOOD FRAME b. A = 2842 SF c. C =1439 GPM -1500 GPM d. 0 = 0.85 (C-2 OFFICE) e. X = 0.12 f. P = 0.0 WEEKLY TRIP CALCULATIONS: NOTE: INTENDED SITE USE IS LOW VOLUME COMMERCIAL PER APPENDIX F OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD DESIGN MANUAL. DS Tavern Summary of Trip Generation Calculation For 4 Employees of General Office Building June 09, 2020 Average Standard Adjustment Rate Deviation Factor Driveway Volume Avg. Weekday 2-Way Volume 3.32 2.16 1.00 13 W 7-9 AM Peak Hour Enter 0.42 0.00 7-9 AM Peak Hour Exit 0.06 0.00 7-9 AM Peak Hour Total 0.48 0.71 1.00 1.00 1.00 2 0 2 00 4-6 PM Peak Hour Enter 0.08 0.00 4-6 PM Peak Hour Exit 0.0.0 4-6 PM Peak Hour Total 0.46 46 0.7 Saturday 2-Way Volume 0.54 0.80 1.00 1.00 1.00 1.00 0 2 2Q� 2 U [- Hq--i O0 Saturday Peak Hour Enter 0.05 0.00 Saturday Peak Hour Exit 0.04 0.00 Saturday Peak Hour Total 0.09 0.31 1.00 1.00 1.00 0 0 0 V O 1 n z �j- Note: A zero indicates no data available. Source: Institute of Transportation Engineers Trip Generation, 7th Edition, 2003. TRIP GENERATION BY MICROTRANS Summary of Trip Generation Calculation For 1.73 Th.Gr.Sq.Ft. of General Office Building 7 COMMENTS 1/10/2022 June 17, 2020 Average Standard Adjustment Rate Deviation Factor Driveway Volume 6 COMMENTS 11/5/2021 Avg. Weekday 2-Way Volume 11.01 6.13 1.00 19 5 MINOR AMNDMNT 8/9/2021 7-9 AM Peak Hour Enter 1.36 0.00 1.00 2 7-9 AM Peak Hour Exit 0.19 0.00 1. 00 0 4 PERMIT SET 12/30/20 7-9 AM Peak Hour Total 1.55 1.39 1.00 3 3 CO. COMMENTS 12/10/20 4-6 PM Peak Hour Enter 0.25 0.00 1.00 0 4-6 PM Peak Hour Exit 1.24 0.00 1.00 2 4-6 PM Peak Hour Total 1.49 1.37 1.00 3 Saturday 2-Way Volume 2.37 2.08 1.00 4 2 COMMENTS 8/18/20 Saturday Peak Hour Enter 0.22 0.00 Saturday Peak Hour Exit 0.19 0.00 1.00 1.00 o 0 NO. _ REVISION/ISSUE DATE Saturday Peak Hour Total 0.41 0.68 1.00 1 JOB NUMBER: 19066 Note: A zero indicates no data available. DATE: MAY 26, 2020 Source: Institute of Transportation Engineers Trip Generation, 7th Edition, 2003. TRIP GENERATION BY MICROTRANS DRAWN BY: JMT AVERAGE DIRECTION OF TRIPS APPROVED BY: JFG DIRECTIONAL FACTOR FOR US 250 FROM DICK WOODS RD. TO US 29 :.689 DRAWING DESCRIPTION: AVERAGE DAILY DRIVEWAY VOLUME: 19+13 = 32+2 =16 OVERALL SITE PLAN DRIVEWAY VOLUME x DIRECTIONAL FACTOR :16 x .689 =11 DRAWING NUMBER: EAST -BOUND DAILY TRIPS : 11 WEST-BOUND DAILY TRIPS: 5 C-04 PLANTED COVER AND HARDSCAPING IN THE STREAM BUFFER: ,+ 1. EXISTING SHRUB COUNT: 18 ARBORVITAE HEDGE— 2. PROPOSED SHRUB COUNT: 23 8 SMOOTH WITHEROD Ij,+ \\I\ 0 DOGWOOD \\I%/%+ \I\ 3. EXISTING PLANTED COVER: 1,265 SF I + /�i\\ 4. PROPOSED PLANTED COVER: 2,792 SF 3 REDCEDAR DOGWOOD 5. EXISTING HARDSCAPE AREA: 2,034 SF 6. PROPOSED HARDSCAPE AREA: 1,648 SF + /'tI N \\\ I �=f/ + 3 SWEETSHRUB 3 1 HOLLY \�\ 2 BOTTLEBRUSH BUCKEYE \IP/ +Cc zl\ + 3 BAYBERRY \\ram DOGWOOD 01 / IIj-�- I \\� Cc8"Ev. MAGNOLIA 2 SWEETSHRUB c \ U \\ E \ U \ \ / z \\ I �1/ + _ \ 1 SHUMARD OAK \I� + oI\\ 10 I \\ /�/'/ �-- 34" TU LIP POPLAR FLAGPOLE DOGWOOD d I 1 \ 5 SPICEBUSH i -r v v i l_ L.O W OAK 2 FRINGETREE \\ Ij + GRAVEL DRIVE 3 \ AND PARKING 2 BAYBERRY Q� ST. JOHNSWORT ST. JOHNSWORT -� 2 SWEETSHRUB- 0 1 HOPHORNBEAM—i ST. JOHNSWORT �_, T 3 SWEET SHRUB - j' Dec. MAGNOLIA ADA COMPLIANT a �. GRAVEL GRID v) o� 3 2 0 u I1 u 1" EXISTING 1 STORY HOUSE 1303 SF FFE 527.91 60AKLEAFHYDRANGEA 8 PLUM YEW 1 WITCHHAZEL O ------ -- \ CRITICAL STEEP SLOPES \ I I I I JI / �-4 BOXWOOD 3 SWEETBAY 1 YELLOWWOOD- ST. JOHNSWORT 2 CRAPE MYRTLE cRass 4 ACUBA ` EXISTING 2 STORY HISTORIC TAVERN 1612 SF FFE 526.94 ST. JOHNSWORT / 2 STORY ADDITION 979 SF FFE 526.83 � (AT REAR ENTRANCE) PROPOSED 1 STORY ADDITION 285 SF FFE 526.60 ;(FROM PATIO) AND LANDSCAPING - / / eo./ County of Albemarle Conservation Plan Checklist — To be placed on Landscape Plans (Handbook, pp III-284-111-297 for complete specifications) 1. The followhrg items shall be shown on the plan: ❑ Trccs to be saved; ❑ Limits of clearing (outside dripline of trees to be saved); ❑ Location and type of protective fencing; ❑ Grade changes requiring tree wells or walls; ❑ Proposed trenching or tunneling beyond the limits of clearing. 2. Markings: ❑ All trees to be saved shall be marked with print or ribbon at a height clearly visible to equipment operators. ❑ No grading shall begin until the tree marking has been inspected and approved by a County Inspector. 3. Pre -Construction Conference: ❑ Tree preservation and protection measures shall be reviewed with the contractor on site. 4. Epulpment Operation and Storage: ❑ Heavy equipment, vehicular traffic and storage of construction materials including soil shall not be permitted within the driplines of trees to be saved. 5. Soil Erosion and Stormwaler Detention Devices: ❑ Such devices shall not adversely affect trees to be saved. 6. Fires: Q Fires are not permitted within 100 feet of the dripline of trees to be saved. 7. Toile Materials: ❑ Toxic materials shall not be stored within 100 feet of the dripline of trees to be saved. 8. Protective Fencing: ❑ Trees to be retained within 40 feet of a proposed building or grading activity shall be protected by fencing. ❑ Fencing shall be in place and shall be inspected and approved by a County Inspector prior to grading or construction. 9. Tree Wells: El When the ground level must be raised within the dripline of a tree to be saved, a tree well shall be provided and a construction detail submitted for approval. 10. Tree Walls: ❑ When the ground level must be lowered within the dripline a tree to be saved, a tree wall shall be provided; and a construction detail submitted for approval. I1. 'trenching and •runneaW ❑ When trenching is required within the limits of clearing, it shall be done as faraway from the trunks of trees as possible. Tunneling under a large tree shall be considered as an alternative when it is anticipated that necessary trenching will destroy feeder roots. 12. Cleanup: ❑ Protective fencing shall be the last items removed during the final cleanup. 13. Damaged Trees: ❑ Damaged trees shall be treated immediately by pruning, fertilization or other methods recommended by a tree specialist. NOTE: IT IS THE DEVELOPER'S RESPONSIBILITY TO CONFER WITH THE CONTRACTOR ON TREE CONSERVATION REQUIREMENTS. / /ST. JOHNSWORT 1 STEWARTIA 1 BLACKHAW . A SWEETBOX WINTER JASMINE \ 1-6 PRAGUE VIBURNUM DOGWOOD I / 1 HOLLY EXISTING 1 STORY -� BLDG Q 230 SF 1 SPICEBUSH FFE: 525.87 (REAR ENTRANCE) 2SWEETSHRUB 4RHODODENDRON 2 BL) LANDSCAPING PLAN / SCALE: 1"=10' GRAPHIC SCALE + \ 20 0 10 20 40 / \ ( IN FEET ) / / \ 1 inch = 20 ft. Botanical Name Common Name aty. Size Root U.C. LARGE TREES Cladrastis kentuckea Yellowwood 1 2-2.5" cal B&B Ilex opaca American Holly 2 8-10' ht B&B VIF Juniperus virginiana Eastern Redcedar 3 6-8' ht B&B VIF Magnolia virginiana Sweetbay Magnolia 3 6-8' ht B&B VIF Ostrya virginiana Hophornbearn 1 2-2.5" cal B&B Quercus shumardii Shumard Oak 1 2-2.5" cal B&B SMALL TREES Chionanthus virginicus Fringetree 2 4-6' ht B&B VIF Lagerstoremia indica 'Natchez' Natchez Crapernyrtle 2 8-10' ht B&B Stewartia monodelpha Tall Stewartia 1 8-10' ht B&B Viburnum prunifolium Blackhaw Viburnum 3 6-8' ht B&B SHRUBS Aesculus parviflora Bottlebrush Buckeye 3 5 gal Cont VIF Aucuba japonica 'Emily Rose' Emily Rose Aucuba 4 3 gal Cont VIF Buxus sempervirens 'Suffruticosa' English Boxwood 4 36" ht/spr B&B VIF Calycanthus floridus 'Aphrodite' Aphrodite Sweetshrub 9 3-4' ht Cont VIF Cephelotaxus harringtonia 'Duke Gardens' Duke Gardens Plum Yew 8 3 gal Cont VIF Hamemelis intermedia Arnold Promise' Arnold Promise Witchhazel 1 5-6' ht Cont Hydrangea quercifolia 'Sike's Dwarf Sike's Dwarf Oakleaf Hydrangea 6 5 gal Cont VIF Lindera benzoin Spicebush 5 3 gal Conk VIF Niyrica pensylvanica Northern Bayberry 10 5 gal Cont VIF Jasminum nudiflorum Winter Jasmine 584 sf 3 gal Cont VIF Rhododendron chinoides Chinoides Rhododendron 4 5 gal Cont VIF Viburnum nudum 'Winterthur' Winterthur Smooth Witherod 8 4-6' ht Cont VIF Viburnum prayense Prague Viburnum 9 5-6' ht Cont VIF GROUND COVER, PERENIALS, VINES, GRASS Hypericum calycinum St. John's Wort 1550 sf 1 gal Cont 18" oc Sarcococca humilis Sweetbox 115 sf 1 gal Cont 24" oc 4x4 PT POST CLAD IN 1x CEDAR ABOVE GRADE x4 CEDAR LATTICE, ?" SPACING, HORIZONTALS f0 OUTSIDE 30TTOM RAIL TO BE SET 3" AINIMUM ABOVE GRADE GRADE 4x4 PT POST SET IN CONCRETE LATTICE SCREEN ELEVATION SCALE: 1 /2" = V-0" C 04 NOTES: 1, SIDE PANEL TO DISMOUNT OR BE SET ON HINGES TO ALLOW FOR MAINTENANCE, 2. LATTICE SCREEN TO BE STAINED PER OWNER'S SPECIFICATION. CHAMFER 4 SIDES OF POST TOP AT 30 ° 2x6 CEDAR TOP RAIL PEAK TOP 112" 44 PT POST CLAD IN 1x CEDAR ABOVE GRADE 1x4 CEDAR LATTICE, 2" SPACING, HORIZONTALS TO OUTSIDE ,- 2x6 CEDAR FRAME GRADE 4x4 PT POST SET IN CONCRETE LATTICE SCREEN SECTION SCALE: 1 /2" = V-0" C-04 A TREE CANOPY SITE AREA: 85,537 SF 10% REQUIRED CANOPY: 8,553.70 SF 51%EXISTING CANOPY: 43,834 SF PARKING LOT LANDSCAPING PARKING LOT AREA: 6,328.50 SF 5% REQUIRED LANDSCAPING: 316.425 SF 29% PROVIDED LANDSCAPING: 2,281 SF J PLANT HEALTH NOTE ALL SITE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED TO REACH, AND SHALL BE MAINTAINED AT, MATURE HEIGHT. 30 THE TOPPING OF TREES IS PROHIBITED. TREES AND SHRUBS SHALL BE PRUNED MINIMALLY AND ONLY TO SUPPORT THE OVERALL HEALTH OF THE PLANT. FIRM INFO: Lineage Architects, P.C. P.O. BOX 991 98 Lee Highway Verona, VA 24482 Phone: (540) 248-3771 Fax: (540) 248-1628 Email: info@lineagearch.com ENGINEER NANIE/SEAL: OF 1' U JONATHAN F. GARBER No. 038568 01 /10/22� NAL E��1 W o w 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 r5TNIINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: LANDSCAPING PLAN DRAWING NUMBER: C-04 A 1,000 GAL. TOP SEAM - CONCRETE PUMP TANK, ORENCO MVP S1/2 DM, ZOELLER E191 - SEE DETAILED SEPTIC PLANS BY OTHER 1,000 GAL. TOP SEAM CONCRETE SEPTIC TANK, 24" RISERS/LIDS,/ ZABEL A30012x20-VC-BALL 55 / 4" SCH. 40 PVC LEANOUT 55 2" SCHEDULE 40 PVC - FORCE MAINZ L N u v u 2 v an 0 v' c /J O v a v gS 3 / 5 CRITICAL SLOPES H / 1 PVC TO IT CLOSET FOR c SEPTIC ALARM / ' ° ROUTE FORCE MAIN OUTSIDE OF CRITICAL SLOPES AREA 3 MAINTAIN MINIMUM 24" y COVER ALONG ENTIRE LENGTH OF FORCE MAIN, o E SEE SANITARY PROFILE N / / E V_ / \ O If 2 SCHEDULE 40 PVC FORCE MAIN 0 u I I 2" SCH. 40 PVC v Cl 0 a v 0 0 r r_ 0 MANIFOLD LATERAL, VB1, TYP. 4 - SEE DETAILED SEPTIC PLANS, BY OTHER a U Qz to c C' lrlll 'av, ,tA t , n ✓L)1I PP'= GVr . C Rt ti D ROCK C!, I It -Tr z.()' OR c . Aft r C`Ar< E }<Abi-1, r s a /1 TO 3/' NC t INr S r.. r ;, �, - : }}ice _ / + L' (, PIPE: E 'P tr7 1 1=t}et�ici I �f. 0 780 `,OFT OF )RAINPE 11 lit c /C N," 1— 4 T R, N '_dF, 65 FOOT 1 ON C .J NC- GI"/c:Rf SURr arc RUNOFF rROM �__WVR;NG TSENCHc5 L No REDUCTION IN AREA SUdirIFUTU, SYS _M ALL0+9ED ry, IV4:,JALI- (riMrirlt-.LL) PER F'LAP6 u LDP TRENCH SECTION ° SCALE: NTS J V132, TYP. 4 - 20 . t r ,'n 1, ` � j':I I I nl a_�i a�•t �t I � ll�l'1 L 1, ;•,-1F li} :IIII ��'a • I I 1� I / /,1 VJ (h AV i,.ai .A. SF(_ IIJI�I E' r c.., 56 a .. dG `4lt T JF ZJVE 1 - fR_�C'r,I o-., '�.ir"• .'�iC NprcS ✓J;.K• �JI<'1t.-. . -,N�4f �`iUI.1 _NP. 12 Nt; �NIN;. -'ES 10 IN AQ7 A F(1 •t 'SIJ'I .S lit � SYSCCM Aal- 'NE T; N _L CR. N ELL +'=R PL,,N, LDP TRENCH SECTION (ALT) 6 SCALE: NTS C-04 B 1 EXISTING SEPTIC TANK - TO BE ABANDONED IN PLACE AND GROUTED FULL _ ss �- its - � EXISTING SEPTICss — s, LINES AND TANKS 1 \ TO BE ABANDONED APPROX. LOCATION EXISTING I SANITARY LINES - TO BE i0 / ABANDONED IN PLACE r Lill OFFICE - 17 ^+- (• ll PUMP _ I'AI'v1K 5,000 PSI REINFORCED � CONCRETE PLAN VIEW USE SILICON ADHESIVE SCREW DOWN RISERS WITH BETWEEN RISER JOINTS STAINLESS STEEL SCREWS BRING TO 2" ABOVE GRADE WIT11 EZ SET POLY RISERS HIGH PRESSURE SEALS CONSEAL CS-102 AND 111) `^ (ASTNI 1227) (AS'TM 923) (Asrht C-99o) - — - ' lll r LPll OFFICE PUMP r HIGH PRESSURE SEALS I ZAHEL A300-1 2x20 VC -BALL (ASTINI1227)( r 923) EFFLUNT FILTER EXTEND' kIr1NULE'1'O I� UNDERSIDE OF RISER LID 'I 6- ?HICK [1011014 sEcrluty VIEW NOTES: I. SEPTIC "TANK IS NEW 1,000 GALLON TOP SEANI CONCRETE 'TANK 2. INLET -PER VDH SEWAGE DISPOSAL and HANDLING REGS 3. OUTLET WITFf EFFLUENT FIL'1'Elt 1. TANKS PEN 13TRA'I'IONS NI UST HE WATERPROOFED AND NOT LEAK 5. 24" RISER ON [NLETiOU"rLE'T SIDE OF TANK. 6ANK SHALL. HE 1120 RATED WITH H2O CAST IRON RISER IF LOCATED IN'I'RAPFIC . T rlliEA. 1.000 GAL. TOP SEAM SEPTIC TANK. SCALE: NIS TRAFFIC RATED CLEAN OUT COVER TRAFFIC SURFACE - --' 3000 PSI C( 4" SCH 40 PVC CLEANOUT CAP GRASS t d 9l\� V X 4" SCH 40 PVC_ WYE - TRAFFIC AREA NUN TRAFFIC AREA SANITARY CLEANOUT SECTION SCALE: NTS GENERAL NOTES: FIRM INFO: 1. SEE APPROVED PLANS BY OLD DOMINION ENGINEERING DATED MARCH 23, 2021. Lineage Architects, P.C. 2. ALL PVC TO BE SCHEDULE 40 UNLESS NOTED OTHERWISE.. P.O. Box 991 3. NO FALL IN LDP TRENCHES. 98 Lee Highway 4. PLACE PRESSURE RELEASE VALVE AT ANY INTERMEDIATE HIGH POINTS IN FORCE Verona, VA 24482 MAIN. Phone: (540) 248-3771 Fax: (540) 248-1628 Email: info@,lineagearch.com ENGINEER NAME/SEAL: (SEE IINDbCARIVCf, Leave extra float and pump wiring, coiled in riser C T� Strap all piping to rank with plas4c straps and stainless steel actchor, 2" UNION. 2" HALL VALVE BLDG 24" Ciinimum Openiug /• F�l BRING TO t" ABOVE GRAD sulE 'i STAINLESS STEEL SCREWS W DOWN RISERS gq \ 14'fCH ! .,E'I' POL Y RISERsS AND LID HIGH PRESSURE SEALS CRITICAL SLOPES r i� ASTM lz2n (AS rrvf 923) / \ CONSFALCS-10'2 ,r4rr' —� v ( ) % As rM G J90 ` (I 2° svh 4o Pvc l.l'li 4017 'SEPTIC m. yr Wateaproot' __ �_ DANK , L J seal cundmt with nun hardelail sealer I� �DIi t�1NTIEi.11 `-1 t l I Junction box b h � I High lovel alarm Boat 39" }JIG I PRFS URF• SEALS i Non-corraivz lift ropy ns'rM lzz) (Asrai gas) l check valve \\ • �"�� _ 3/16 vent hole PVC Flum Free \ I - PUNIP OFF 23" Redundant Off! Level Low Level Alarm 19" 1000 Gallon Mid Seam Cmlcrete "Tank Zoeller E191 Effluent Pump 45 -pill Orenco NIVP S1/2 DNI GRAPHIC SCALE 10 20 40 8 SEPTIC PLAN ( IN FEET ) I inch = 20 ft. Valve box I , ; Valve box-," :- J � I (c. .'_0.i-a ..t. ar>,u,,fx l_�Fzrrr x._:T e.r• na:a a �:,_.�+: tNj MCI,- r r t d /y,��v:..�,a;.:[.ii{,rvX �+�.s?~�nFdT•,.Si; d .r�"rat.� ':a;,; rot lGt� i�..� �,�w',',;�i, :�'"�r� ;f� 3/16' %nc r (7C �? hoi(, n,--e tE,,d zorv- P 6 r, rJcC < pos;tloo - 3 rlgl2 , p2r ,p ;:r=rill LDP LATE11 RAL SECTION SCALE: NTS SCALE: 1 "=20' NOTES: 1. PUMP TANK IS TOP SEAM 1000 GALLON CONCRETE TANK 2. INLET - 4" SCH 4o PVC'TEE 7. TANKS PENETRATIONS MUST HE WATERPROOFED AND NOT LEAK. 4. 24" POLY RISER ON OUTLET SIDE OF TANK. 5. STRAP ALL PIPING TO'I'ANK WCTH PLASTIC STRAPS AND S'TAIi ILESS STEEL ANCHORS 6. FLOA"IHEIGH"I'S WILL NEED TO HE ADJUSTED IFTANK DIMENSIONS VARY FRON9 21.64 GALLONS PER INCH 7. EASY ACCESS TO VALVES AND UNIONS LDP DOSING PUMP TANK SECTION SCALE: NIS First 3/16" hole is 2.5' from start of trench Start nfTrencli Nlanitold is 24' deep ° see site plan for inanifold site Valve box I J MANIFOLD TO TRENCH SCALE: NTS 1.)5' >C Hn0 'VC F3ALI_ VAI_V for r trictlnq I jw TRIM AROUND PIPE 1000 Gallon Concrete fop Scam "Punk 21.64 galhn (flanover Mid Seem) Easy access to valves and union:; Float heights will need Labe a•1justed if tame dimensions vary from 2 f.G3 gal/in ' '20 ,ch 40 PVC. ' I,PU SEPTIC 0; _ -: T — — 1)1 4 AiP(i`iELll T' Hall Valve i - - ," union 1000 GALLON MIL) SEAANI CONCRETE TANK LDP DOSING PUMP TANK PLAN SCALE: N IS 1 I/4` SCH 40 PVC yti[) CcA F c mate 1 hrrc ail" 6"RtlutidValveBox I 1/4' SCH 40 PVC ThrerAdp� l t:a� 3 C 4 I C) PVC VALVE BOX 1 9 SCALE: NTS C 04 B 1 1/4' VALVE BOX 2 10 SCALE: NTS C-04 B 6oLTHOF VAC��Ci''IM1•ollll'i/(li't r U JONATHAN F. GARBER :P No. 038668 `�yl /10/22#4 IIIIIIIIOXAL S&i W o U �( H d- w [r� 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: SEPTIC PLAN AND DETAILS DRAWING NUMBER: C-04 B 0 10 0 s 3 r a O s 0 O 3 O 0 E E 0 cu N VI LEGEND SYMBOL CALLOUT I LUMINAIRE TEMP. OUTPUT QTY. A 2700 KELVIN 980 LUMENS F A SHLEEYTHOUSE WALL MOUNTDESIGN - L B 2700 KELVIN 980 LUMENS DEEP LANDING WORKSHOP - L1316B SCONCE F C 2700 KELVIN 490 LUMENS FVAUGHAN - KINGSTON WALL LANTERN D 2700 KELVIN 980 LUMENS ANN MORRIS - MORRIS LIGHT E 3000 KELVIN 210 LUMENS 31 AURORA LIGHT - QUADRANT - 3W 2700 KELVIN 580 LUMENS F HYDREL - ASPEN LED - 30e LIGHTING CUT SHEETS Ic Colonial Ashley House Coach Wall Mount Lantern - SM-LI I BULB SPECS: 2 60 Watt Maximum F-12 Bulbs _- 2700 Kelvin . _-, _...... FIHTSTI: Darkened Teme _... P". ,. GI,ASS: Standard Panc 111, IASTED FOR OUTDOOR USE VAUGHAN Kingston Wall Lantern - FC Finishes Bulb Specification Bulb Base F12 Candelabra Base Max Wattage 40W Bulb Supplied No Vaughan Recommends I FD/7700K/5001m For a brighter light, a bulb with a higher lumen output can be used. Further Information Suitable for outdoor use. C &us WA013 T'K urns gB. 5H' 6.6lbs BZ-Brass Zi-Zinc xi 110V Mains Dimmable lift \� �Itlllllltl \ LISTED Pleaw Note:- These notes are for guidance only. Vaughan accepts no responsibility for any installation using the above notes. The final decision on installation remains with the installer. vaughandesigns.corn 0 L-1613B - FIB 15 /," high s S" wide X 5 /, • deep pn.pnYs 6' Twu.andalabra (EI2) srxke•ts 60 went — each / 2700 Kelvin UL Lisud for (III III Finish in I'LN-IN.CC, dark Mad a.at copper Class is GI-R.5L hand made—turxtkm glass A N N— M O R R I S N E W Y O R K t 1 MORRIS LIGHT - FINISH: STATUARY BRONZE 8" DIAMETER X 4• DEPTH LAMPING: (2) SOCKETS PER FIXTURE- UP TO 40 WATTS PER SOCKET INCANDESCENT OR UP TO 60 WATTS PER SOCKET LED LAMPBASE:MEDIUM BASE(E26) 2700K UL LISTED FOR OUTDOOR USE A- M The LPL/ Q clas uaBgH e-e si-a d and - tallied to n quality and pedormanc'C standard never before available. Featuring a heavy duty architectural brass stem Ingeniously coupled to the robust die-cast bras:; hood with no visible hardware. Available in two distributions and wattages Featuring Inciudo: • 3 Watt Single LED or 7 Watt Triple LED • Up to 260 lumens at 3000K • Cme xP-LID High Density LED (CRI 801yp.) • 2700K (80 & 90 CRI) or 3000K (80 CRI), or Amber 585-591 Thermally IntegratedN and Field Serviceable LED Mosul, • 12V Integral Dover, Dimmable to <I0%typ. Compatible w/ 12V ACIDC FILM or MI V Transformers • Solid Copper and Brass Construction LIGHT DISTRIBUTION CHOICES. - t4• t SEE NEXT PAGE FOR ORDERING INFORMATION LARLSBAO.CA I PHONE 87791211791 FAX 7W03129;61 E-MAIL SAtFSSAUR(RALO TC� 6 1 i n•w.,mu•w Amin+rom-mrll�w.mw,a«.Iw,.......e.�w,am.mr P,rowa we,"ra�.„,•wIM nounre,. omro.,,on•e,' ^< wv-sa(bwv Lana For amaNer ar ,, .•zc „y 1, I III LPi;i 5, d L1 L II For other wattage and size options sea HPL Sifnex O■DewNO DUIDEI L►LTI L )LED) R. )PATH LIGHT) 6111 SO (SQUARE) ss.w•aeo P 1� LPL'r-fa -7dT-7De-NAr L►LT-lO E) _� a Aeemurtuaunor.+ ua sioubis Assail"......Mou rnaw0 Gs dmo 1-11 oa. :.i Bu,_Ne eJ r 1t-0,a M.a; e m 7w Pawdu.mansn Latin 27001 sac I.asl Gana, 1 1.:.. (Na7iNrxn: Iasi 36owc. s cis Pall Gwm sire . J cy, Fw.IN Ismal Arse IX—] Ga.M s,r..3la cro teLF, 166sa95,ui') ,ra-ta (INJ of xu•s:.cr;:. NOiE'. Faller Ce`a,a arI eq4+. mv.c„o-,w aea-a J ew,.r 5,rn 1 ' ev 1•m;u8 IRnt Na d rvn n. v«lire (-1] 3 "1 -1— ACCESSORIES MOUNTS CARLSBAD, CA I PHONE 87794211191 FAX 76093, 29161 E- MAIL SAL ESGAURORALIGHT COM I AURORA 16 I.OM 0Y5 '.•'^' nemnMenypWualuryxorem•nip,quo. auiurrPe w.•rw•hryn,bncy7 pwua.P.,.rrsw+•.,r•ul nov.rNn Oxaae sumr•uy,,. c fin U,Aml [ -.-. {sits LIGHTING NOTES: vs 1. ALL LIGHTING SHALL: a. BE EQUIPED WITH AUTOMATIC TIMING DEVICES AND SHALL BE EXTINGUISHED W BETWEEN THE HOURS OF 11:00 P.M. AND DAWN. b. BE SHIELDED AND FOCUSED TO ELIMINATE GLARE. GLARE CONTROL SHALL BE ACHIEVED PRIMARILY THROUGH THE USE OF SUCH MEANS AS CUTOFF FIXTURES, SHIELDS AND BAFFLES, AND APPROPRIATE APPLICATION OF MOUNTING HEIGHT, WATTAGE, AIMING ANGLE, FIXTURE PLACEMENT, ETC. Coll p; c. BE CUTOFF LUMINAIRES, AIMED SO AS NOT TO PROJECT THEIR OUTPUT BEYOND w THE OBJECTS INTENDED TO BE ILLUMINATED; OR NON -CUTOFF LUMINAIRES, Z EQUIPPED WITH GLARE SHIELDS, VISORS, BARN DOORS, AND/OR OTHER SIMILAR ►-4 SHIELDING ACCESSORIES AS REQUIRED TO MEET THE FOLLOWING CRITERIA: Z LIGHT DISTRIBUTION FROM ALL LIGHTING INSTALLATIONS SHALL BE CUT-OFF AT w ALL ANGLES BEYOND THOSE REQUIRED TO RESTRICT DIRECT ILLUMINATION TO WITHIN THE PERIMETER OF THE LANDSCAPE FEATURE BEING ILLUMINATED. d. NEVER EXCEED 3,000 LUMENS. FURTHER RESTRICTIONS ON LUMENS MAY BE U IMPOSED BY THE ARB. W e. NOT BE MODIFIED TO REFLECT SEASONAL COLORS" Eassal Ississal f. BE OF A NUMBER THAT IS COMPATIBLE WITH THE SCALE OF THE OBJECT AND THE DEVELOPMENT TO BE ILLUMINATED, SUCH THAT THE LIGHT EMITTED WILL NOT OVER -ILLUMINATE OR OVERPOWER THE SITE, AS DETERMINED BY THE ARB. 2. EACH OUTDOOR LUMINAIRE EQUIPPED WITH A LAMP THAT EMITS 3,000 OR MORE INITIAL LUMENS SHALL BE A FULL CUTOFF LUMINAIRE AND SHALL BE ARRANGED OR SHIELDED TO REFLECT LIGHT AWAY FROM ADJOINING RESIDENTIAL DISTRICTS FIRM INFO: AND AWAY FROM ADJACENT ROADS. THE SPILLOVER OF LIGHTING FROM Lineage Architects, P.C. LUMINAIRES ONTO PUBLIC ROADS AND PROPERTY IN RESIDENTIAL OR RURAL P.O. Box 991 98 Lee Highway AREAS ZONING DISTRICTS SHALL NOT EXCEED ONE HALF FOOT-CANDLE. Verona, VA 24482 3. PHOTOMETRIC MODEL PREDICTS 0.0 fC AT PROPERTY BOUNDARIES. 4" NO TALL POLE MOUNTED LIGHTING IS PROPOSED FOR THIS PROJECT. Phone: (540) 248-3771 Fax: (540) 248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: J40yTH op C)JONATHM F. GABBER 9 No. 038588 S01 /10/22 4v (•T•a uw� 0 HYDREL ASPEN LED I3 rTl PERFORMANCE DATA ASPEN LEDOUrPUT E"I 12V/120V LED.. ... r,...d ®a r.asx.w»■o '.mr.,..w.P �...aa.raa.n.. - e.<.w.. dwun*r. N+.«.. a O ^ ...din....,w,..+•.m.,.a�.c.,.a,..w,.r.,e"•,.<.s..n.•4•r a..,s... fy ��11 F+1 HIGHLIGHTS [� l xn, so, s.rs V • Accent lights arc suitable for a variety of mounting AON applications nclud ng 9—ird, wall, tree sign and °0° archltadural accents 5i hovw a 01 oI • Suitable for wet locations ...•.r � � O • Integral drverfor 120V Dimmable with low voltage magnetic dimmer 6a • T pared -sure lack 11 • Available in 80CRI and 90CRI •Ae• A7N 1.Tau Las as a +� 1,1001m ®. 7,7vm" „ 7.»+ ssn i n » N N .1, w 1. aH .1, 77 m n. 1. �m7 .» H 'a7 ,,6os N DIMENSIONS \^�• LUMEN PACKAGES ✓.G �"'���• Imo, u.ewi w as Mw .. w W •, ,7ov., „ ;7W ; /\ o w " uA o N 7 u l w ��^ .HMMWarN r,Nma•r+7�wc x3i voa.r c+up ra RCW c, eora » » N N ew {M M .,. ,.7 N 41 11w N+ N r7 r ,. 7 COMMENTS 1/10/2022 STANDARD DISTRIBUTION 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 cl - - a PHOTOMETRIC DIAGRAMS _ sass■ As. io sin caylr•Phaamab2.•Pwowdo,.•b•d 'r fik.b M4 pods+, .4'n 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: SITE LIGHTING PLAN DRAWING NUMBER: C-04 C 1LZ C N N C O U C O C oSTR# 1 E 2' SCH. 40 PVC STR# 2 a FORCE MAIN 2' SCH. 4D FORCE INV. IN = 524 20' MAIN • c 3 v� W c c I�l v H 0 570 rrY--h4 Z o r!, W 21 o o_ T � t_ r\T./l a W c v 565 Err.LI{� 0 FIRM INFO: Lineage Architects, P.C. P.O. Box 991 98 Lee Highway a 560 Verona, V 24482 Phone: (540) 248-3771 i Fax: (540) 248-1628 a Email: into@lineagearch.com ° J ENGINEER NAME/SEAL: O O .N ,LTH OP v 555 ��` p a. C�u: 3 U10NATHAN F. GARBER No. 038568 ,�01 /10/22 ,$ 1 `sIONAL ��Cs .o 550 r 3 O O 3 545 0 E `O c v .c o O 540 �. \ U 0 o o W a H H x C) v 535 2 c O � O v N a v 0 a 530 7 COMMENTS 1/10/2022 WS 6 COMMENTS 11/5/2021 m 5 MINOR AMNDMNT 8/9/2021 a 4 PERMIT SET 12/30/20 -v 525 3 CO. COMMENTS 12/10/20 c v s 2 COMMENTS 8/18/20 Q NO. REVISION/ISSUE DATE 3 v 0 JOB NUMBER: 19066 E E DATE: MAY 26, 2020 N 520 I o DRAWN BY: JMT aNi 09+75 10+00 11+00 12+00 13+00 13+25 T APPROVED BY: JFG y a DRAWING DESCRIPTION: a SANITARY FORCE MAIN PROFILE GRAPHIC SCALE 30 _ 30 FORCE MAIN PROFILE DRAWING NUMBER: SCALE: 1 "= 3Q' o ( IN FEET )C-04 D 1 inch = 30 ft. SCALES: 1' = 30' HOR. INV. OUT= 559.40' 1" = 3' VER 09+75 10 00 11+00 12+00 13+00 13+25 570 565 560 555 550 545 540 535 MAINTAIN MINIMUM 24" COVER 530 V A EXISTING GRADE 525 520 Z o Z o 0 o ¢ w� ,FM H 3 c E E 0 TIa al 0 O C C I 3 O c E E 20 i U E U i CRITICAL SLOPES GRAPHIC SCALE 10 20 40 ( IN FEET ) 1 inch = 20 ft. 1 ` \ I , , I ` I m IVY ROAD \ 1 .ID US ROUTE 250 I 1 C \ -n `\ Irn 80.00' R.O.W. I --- --- ---- , ------------- _ (SINGLE �z5"uI\ ( \ (P), ,-'--'---111 350 \ RISER) \ .40' 525.56' 525'\'lid 526.35' �15.68' S ' _ ! 525 98 / 526 On \ \ \ \ 526 \ \ 525.90 / 545 p CRITICAL SLOPES 00 , 1 1it \ \ \ \ \ \ 1 I I I 1 I I � .,• \ I I I Mill I I 1 1 1 ' I I I I 1 \ \ I 1 1 I 1 1 I I -_______-- Ln CD Q \ II 1 I I • 1\ 1 � I I 1 I ; _ Ln - / I 11 I, I \ 5 1 I , , . , ' II 35 00 GRADING/E&SC PLAN SCALE: 1 "=20' w� FIRM INFO: Lineage Architects, P.C. P.O. Box 991 98 Lee Highway Verona, VA 24482 Phone: (540) 248-3771 Fax: (540) 248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: 40LTH pp"�, U JONATW F. GARBER 9 No. 038568 1.0t�01 /10 /2 2� � o � W � rl � H H H uo fr 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: GRADING/E&SC PLAN DRAWING NUMBER: C-05 3 a a 0 i 'v- 0 t 3 0 a 0 N N L 0 4" #57 STONE SECURED w/ GravelPave OR APPROVED EQUIVALENT 4" HEAVY STONE 12" RDC, COMPACTED w/ SHEEP'S FOOT ROLLER IN TWO EQUAL LIFTS X X 1 I I1 I I1 I I1 I I1 I I1 I I1} I I1 I I1 I I1 I IIIIIII1 I I1 11 NOTE: THIS DETAIL SHALL NOT BE USED FOR L EXISTING SOIL COMPACTED TO ACCESSIBLE PARKING SPACES AND 95% STD PROCTOR DENSITY THE AISLE BETWEEN THEM. REMOVE INCOMPETENT SOIL HEAVY DUTY GRAVEL DETAIL SCALE: N IS 1150mm (45.27") 575mm (22.63") 575mm (22.63") E E 0 0 L _ r� of M E 0 0 00 rn E E 0 0 010W JOH0 JUJIJ WIJ 0 0 0 Wd U 40mm (1.57") 13REENDRIVEWAY GD GRAVEL 60-40 A GREEN ALTERNATIVE FOR PAVING AND LANDSCAPING WEB: greendriveway.com Email: Info@greendriveway.com GRAVEL GRID DETAIL SCALE: NTS —PRECAST CONCRETE OR CUT STONE CURB —BRICK PAVER 3 (80 MM) MIN THICKNESS — 1" TO 1 2" (25 TO 40 MM) BEDDING SAND — GEROTEXTILE 12" (300 MM) WIDE, TURN UP AGAINST CURB — COMPACTED AGGREGATE BASE — GEOTEXTILE AS REQUIRED TURN UP AT SIDES OF BASE d p p d p p COMPACTED SOIL SUBGRADE -- COMPACTED AGGREGATE OR COMPACTED BEDDING NOTE: 1. EDGE RESTRAINT SHOULD BE MINIMUM 6 IN. (150 MM) WIDE FOR STREET APPLICATIONS. 2. EDGE RESTRAINT MAY BE EVEN WITH TOP OF BRICK PAVERS. 3. THICKNESS OF AGGREGATE BASE WILL VARY WITH SUBGRADE CONDITIONS AND CLIMATE. COLDER CLIMATES MAY REQUIRE THICKER BASES. PAVER SECTION SCALE: NTS GRAVEL DRIVE FLU,' GRADE BEL TURF NOTE: 1. STEEL EDGING TO BE 1/8"X4" (.120—.125" AVERAGE THICKNESS) OR EQUIVALENT. STEEL EDGING DETAIL SCALE: NTS STANDARD ALUMINUM SIGN ALUMINUM "VAN —ACCESSIBLE" SIGN 2"X2" STL. TUBE, EXTEND 2'-0" INTO CONC. FILLED PIPE 6" DIA. STD. STL. PIPE FILLED WITH CONCRETE #6 BARS EACH WAY THRU PIPE 8» d RESERVED PARKING O PENALTY $100-500 FINE OW AWAY ZON VAN -ACCESSIBLE 00 N HANDICAP PARKING SIGN SCALE: NTS ° wa FIRM INFO: Lineage Architects, P.C. P.O. Box 991 98 Lee Highway Verona, VA 24482 Phone: (540)248-3771 Fax: (540)248-1628 Email: info(olineagearch.com ENGINEER NAME/SEAL: 4��TH 0� U JONATHAN F. GARBER 0;- No. 038668 �t�01 /10/22� 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISIONASSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: CONSTRUCTION DETAILS DRAWING NUMBER: C-06 m 3 D L 0 1 527 I I HANDICAP SIGN MOUNTED ON POST, DESIGN BY OTHER o s 0 stop 07iax J F 525.95' (TOP OF WALK) NOTES 1. SLOPES IN PARKING SPACES SHALL NOT EXCEED 2%. 2. SLOPE OF WALKWAY SHALL NOT EXCEED 5%. 3. CROSS SLOPE OF WALKWAY SHALL NOT EXCEED 2%. 4. ALL SURFACE MATERIALS SHALL BE ADA COMPLIANT. HANDICAP PARKING LAYOUT SCALE: 1" = 5' 0801 DI APPROX. DRAIN AREA = 19.30 SQ IN APPROX. WEIGHT = 5.80 LE S 09.85 18 x .50 1.25 31 j 07.85 DIMENSIONS ARE FOR REFERENCE ONLY ACTUAL DIMENSIONS MAY VARY THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH DIMENSIONS ARE IN INCHES NYLOPLAST RAS PROPRIETARY RIGHTS. THE RECEIPT GRATE HAS LIGHT DUTY RATING OR POSSESSION OF THIS PRINT ODES NOT CONFER, QUALITY: MATERIALS SHALL CONFORM TOASTMA535 GRADE 70.50-05 TRANSFER, OR LICENSE THE USE OF THE DESIGN OR PAINT: CASTINGS ARE FURNISHED WITH A BLACK PAINT TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION SIZE OF OPENING MEETS REQUIREMENTS OF AMERICAN DISABILITY CONTAINED HEREIN, OR MANUFACTURE OF ANY ACT AS STATED IN FEDERAL REGISTER PART III, DEPARTMENT OF ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS JUSTICE, 28 CFR PART 36. IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM HYLOPLAST, ----avow NYLOPLAST 8" DROP —IN GRATE SCALE: NTS 3130 VERONA AVE aUFORD, GA 30513 PHN (T70) 9323443 FAX (770) 9322490 N ast www.n to 4w.cam >� Iat Y P JLJ.JU (TOP OF WALK) ADA COMPLIANT GRAVEL GRID BRICK PATHWAY WHEEL STOP, typ. 2 DESIGN BY OTHER 526.79' (TOP OF WALK) 526.79' (TOP OF WALK) 1�• SEE DRAWING NO.7001-110-275 FOR ADS N-12 & HANCOR DUAL WALL BELL INFORMATION 02 - SEE DRAWING NO.7003-110-031 FOR WATER TIGHT SWAGE JOINT DETAIL 3 - DIMENSIONS ARE FOR REFERENCE ONLY ACTUAL DIMENSIONS MAY VARY 4 • DIMENSIONS ARE IN INCHES NYLOPLAST 8 x 8 TEE SCALE: NTS INTERIOR VESTIBULE FFE = 526.83 2" THRESHOLD 5' LANDING FFE = 526.79 NOTE: 1. NO HANDRAILS REQUIRED. 2. ACTUAL CROSS SECTION DESIGN BY LANDSCAPE ARCHITECT. 3. MORTAR JOINTS ON AN ACCESSIBLE PATH MAY NOT EXCEED "' DEPTH. ADA RAMP TO PATIO SECTION SCALE: NTS 1 17.75 1 THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT OR POSSESSION OF THIS PRINT DOES NOT CONFER, TRANSFER, OR LICENSE THE USE OF THE DESIGN OR TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION CONTAINED HEREIN, OR MANUFACTURE OF ANY ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST. 3130 VERONA AVE BUFORD, GA 30518 Nylo last PHN (770) 932.2443 FAX (770) 932-2490 www.nylop ast us com 5.25' RAMP SLOPE — 8.337. ~� U FIRM INFO: BRICK PATIO Lineage Architects, P.C. P.O. Box 991 F F E= 526.35 98 Lee Highway Verona, VA 24482 Phone: (540) 248-3771 Fax: (540)248-1628 Email: info@lineagearch.com ENGINEER NAME/SEAL: .LTH OF� 11 U JONATW F. GARBER �> No. 038568 WdS�01 /10/22 .$ M SIONAL Ets1 a U � o � W U H O F-1 U r� v a, r1' U Q C 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISION/ISSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: HANDICAP PARKING LAYOUT & CONSTRUCTION DETAILS DRAWING NUMBER: C-06 A f"'I 1 1lL w( D Q JL INTERNATIONAL SOCIETY OF ARBORICULTURE DO NOT HEAVILY PRUNE THE TREE AT PLANTING. PRUNE ONLY CROSSOVER LIMBS, CO -DOMINANT LEADERS, AND BROKEN OR DEAD BRANCHES. SOME INTERIOR TWIGS AND LATERAL BRANCHES MAY BE PRUNED; HOWEVER, DO NOT REMOVE THE TERMINAL BUDS OF BRANCHES THAT EXTEND TO THE EDGE OF THE CROWN. STAKE TREES ONLY UPON THE APPROVAL OF THE LANDSCAPE ARCHITECT SEE STAKING DETAIL. WRAP TREE TRUNKS ONLY UPON THE APPROVAL OF THE LANDSCAPE ARCHITECT. SEE WRAPPING DETAIL. INTERNATIONAL SOCIETY OF ARBORICULTURE 1400 WEST ANTHONY DRIVE CHAMPAIGN, IL 61821 (217) 355-9411 (217) 355-9516 FAX EACH TREE MUST BE PLANTED SUCH THAT THE TRUNK FLARE IS VISIBLE AT THE TOP OF THE MARK THE NORTH SIDE OF THE TREE IN ROOT BALL. TREES WHERE THE THE NURSERY, AND ROTATE TREE TO TRUNK FLARE IS NOT VISIBLE FACE NORTH AT THE SITE WHEN EVER SHALL BE REJECTED, DO NOT POSSIBLE. COVER THE TOP OF THE ROOT BALL WITH SOIL, SET TOP OF ROOT BALL FLUSH TO MULCH RING 1800 MM 6 FT. ( ) GRADE OR 25-50 MM (1-2 IN.) HIGHER IN DIAM. MIN. 2400 MM 8FT. DIAM. 100 MM (4 IN.) HIGH EARTH SLOWLY DRAINING SOILS, PREFERRED SAUCER BEYOND EDGE OF ROOT BALL. 200 MM (8 IN.) IIII� ullip „M, Alm lip" NIINYeiuiYYIYIYYp REMOVE ALL TWINE, ROPE AND 50 MM (2 IN.) MULCH. DO NO PLACE , ,' ',',' ',',', , :',',',',', WIRE, AND BURLAP FROM TOP '+'t't'i'i' MULCH IN CONTACT WITH TREE TRUNK. i'f'i' r'+'+' HALF OF ROOT BALL MAINTAIN THE MULCH WEED -FREE FOR A MINIMUM OF THREE YEARS AFTER IF PLANT IS SHIPPED WITH A WIRE BASKET AROUND THE PLANTING. ROOT BALL, CUT THE WIRE BASKET IN FOUR PLACES AND FOLD DOWN 200 MM (8 IN.) INTO PLANTING HOLE. NOTE: FOR DIMENSIONS OF PLANTING PLACE ROOT BALL ON UNEXCAVATED AREAS, TYPES OF SOIL AMENDMENTS, OR TAMPED SOIL. OR SOIL REPLACEMENT, SEE "SOIL IMPROVEMENT DETAILS." TAMP SOIL AROUND ROOT BALL BASE FIRMLY WITH FOOT PRESSURE SO THAT ROOT BALL DOES NOT SHIFT. NOTES 1. PLEASE REFER TO INTRODUCTION AND USE CRITERIA PRIOR TO USING THIS DETAIL. TREE PLANTING DETAIL - B&B TREES IN ALL SOIL TYPE NOTE: THIS DETAIL ASSUMES THAT THE PLANTING SPACE IS LARGER THAN 2400 MM (8 FT.) SQUARE, OPEN TO THE SKY, AND NOT COVERED BY ANY PAVING OR GRATING. TREE PLANTING DETAIL SCALE: NTS INTERNATIONAL SOCIETY OF ARBORICULTURE . TWO -WALLED PLASTIC SHEETING OR TREE SHELTER MATERIAL APPLIED FROM TRUNK FLARE TO FIRST BRANCH BIO-DEGRADABLE PLASTIC TAPE APPLY THE PLASTIC SHEETING LOOSELY AROUND THE TRUNK TO LEAVE A 12 MM (0.5 IN.) GAP BETWEEN THE TRUNK AND THE SHEETING. OPTION 1 OPTION 2 INTERNATIONAL SOCIETY OF ARBORICULTURE 1400 WEST ANTHONY DRIVE CHAMPAIGN, IL 61821 (217) 355-9411 (217) 355-9516 FAX BREATHABLE FABRIC TREE WRAP APPLIED FROM TRUNK FLARE TO FIRST BRANCH. WRAP PAPER FROM THE BOTTOM UP WITH SUFFICIENT OVERLAP TO COVERALL BARK. BIO-DEGRADABLE PLASTIC TAPE, TREE WRAP SHOULD BE INSTALLED AT TIME OF PLANTING AND BE REMOVED WHEN DIRECTED BY THE LANDSCAPE ARCHITECT, BUT NO LATER THAN 12 MONTHS AFTER PLANTING, TREES WHOSE NORTH ORIENTATION IS NOT CHANGED FROM THE NURSERY DO NOT NEED TO BE WRAPPED EXCEPT TREES WITH VERY THIN BARK, SUCH AS RED MAPLE, SHOULD BE WRAPPED IF APPROVED BY THE LANDSCAPE ARCHITECT. NOTES 1. PLEASE REFER TO INTRODUCTION AND USE CRITERIA PRIOR TO USING THIS DETAIL. TREE WRAPPING DETAIL No. 145-002 TREE WRAPPING DETAIL SCALE: NTS INTERNATIONAL SOCIETY OF INTERNATIONAL SOCIETY OF ARBORICULTURE 1400 WEST ANTHONY DRIVE CHAMPAIGN, IL 61821 ARBORICULTURE (217) 355-9411 (217) 355-9516 FAX WIRE OR CABLE SIZES SHALL BE AS FOLLOWS: TREES UP TO 65 MM (2.5 IN.) CALIPER -14 GAUGE TREES 65 MM (2.5 IN.) TO 75 MM (3 IN.) CALIPER -12 GAUGE TIGHTEN WIRE OR CABLE ONLY ENOUGH TO KEEP FROM SLIPPING. ALLOW FOR SOME TRUNK MOVEMENT. PLASTIC HOSE SHALL BE LONG ENOUGH TO ACCOMMODATE 35MM (1.5 IN.) OF GROWTH AND BUFFER ALL BRANCHES FROM THE WIRE. TUCK ANY LOOSE ENDS OF THE WIRE OR CABLE INTO THE WIRE WRAP SO THAT NO SHARP WIRE ENDS ARE EXPOSED. 13 MM (0.5 IN.) DIAM. �l PLASTIC HOSE GALVANIZED WIRE OR CABLE TWIST WIRE TO TIGHTEN. 240 x 40 MM (1.5 x 1.5 IN.) E HARDWOOD STAKES OR OTHER N APPROVED STAKE MATERIAL o� 0 ALL STAKES SHALL BE DRIVEN OUTSIDE II" THE EDGE OF THE ROOT BALL.jmtm 1( ASSURE THAT THE BEARING SURFACE OF THE PROTECTIVE COVERING OF THE WIRE OR CABLE AGAINST THE TREE TRUNK IS A MINIMUM OF 12 MM (0.5 IN.). REMOVE ALL STAKING AS SOON AS THE TREE HAS GROWN SUFFICIENT ROOTS TO OVERCOME THE PROBLEM THAT REQUIRED THE TREE TO BE STAKED. STAKES SHALL BE REMOVED NO LATER THE END OF THE FIRST GROWING SEASON AFTER PLANTING. TREES NORMALLY DO NOT NEED TO BE STAKED AND STAKING CAN BE HARMFUL TO THE TREE. STAKING SHOULD BE DONE ONLY WITH THE APPROVAL OF THE LANDSCAPE ARCHITECT IF IT IS EXPECTED THAT THE TREE WILL NOT BE ABLE TO SUPPORT ITSELF. THE FOLLOWING ARE REASONS WHY TREES DO NOT REMAIN STRAIGHT. •TREES WITH POOR - QUALITY ROOT BALLS OR ROOT BALLS THAT HAVE BEEN CRACKED OR DAMAGED. REJECT RATHER THAN STAKE. *TREES THAT HAVE GROWN TOO CLOSE TOGETHER IN THE NURSERY, RESULTING IN WEAK TRUNKS. REJECT RATHER THAN STAKE. *PLANTING PROCEDURES THAT DO NOT ADEQUATELY TAMP SOILS AROUND THE ROOT BALL. CORRECT THE PLANTING PROCEDURE. *ROOT BALLS PLACED ON SOFT SOIL. TAMP SOILS UNDER ROOT BALL PRIOR TO PLANTING. *ROOT BALLS WITH VERY SANDY SOIL OR VERY WET CLAY SOIL. STAKING ADVISABLE. *TREES LOCATED IN A PLACE OF EXTREMELY WINDY CONDITIONS. STAKING ADVISABLE. NOTES 1. PLEASE REFER TO INTRODUCTION AND USE CRITERIA PRIOR TO USING THIS DETAIL. � TREE STAKING DETAIL - TREES 75MM (3 IN.) CALIPER OR LESS TREE STAKING DETAIL SCALE: NTS TREE FENCING AND ARMORING DETAIL SCALE: NTS DRIP LINE PROTECTIVE DEVICE n MAXIMUM LIMITS OF CLEARING AND GRADING PROPOSED GRADING \ awrrllY w w w w MIN 5' WHERE DRIP LINE IS LESS THAN 5' ww w war CONSTRUCTION OPERATIONS RELATIVE TO THE LOCATION OF PROTECTED TREES TREE PROTECTION DETAIL SCALE: NTS FIRM INFO: Lineage Architects, P.C. P.O. Box 991 98 Lee Highway Verona, VA 24482 Phone: (540) 248-3771 Fax: (540) 248-1628 Email: info@lineagearch.com lineagearch.com ENGINEER NAME/SEAL: �LTH OF7 U JONATHAN F. GARBER > No. 038568 01 /10/224� ' &ONAL SV W W W �1 u H 9L4 Cl) 7 COMMENTS 1/10/2022 6 COMMENTS 11/5/2021 5 MINOR AMNDMNT 8/9/2021 4 PERMIT SET 12/30/20 3 CO. COMMENTS 12/10/20 2 COMMENTS 8/18/20 NO. REVISION/ISSUE DATE JOB NUMBER: 19066 DATE: MAY 26, 2020 DRAWN BY: JMT APPROVED BY: JFG DRAWING DESCRIPTION: LANDSCAPING DETAILS DRAWING NUMBER: C-07