December 2021, and find the following:
1. Please remove all Structure and Bridge Standard Details from the plans. S&B standard
details are to be referenced in plan notes: The Standard Drawings contained in the VDOT
Road & Bridge Standards are signed and sealed engineering drawings that are
copyrighted materials of VDOT and the Commonwealth of Virginia. VDOT's policy is to
offer the Standard Drawings in a secure electronic format and each Standard is available
on this website. Plan assemblies using the Road & Bridge Standards shall reference each
standard used. Inserting the Standard Drawings into VDOT, locality, or private
development plan assemblies, or modifying the Standard Drawings in any way, is not
permitted.
2. Please show the mail boxes & cluster box units per RDM Appendix B(1)-56
3. Profile view for Horizon Road does not appear to show the CG-11 requirements as
described in the Road & Bridge Standards. Please show a minimum 5' extension of the
Hickory street cross slope as a parabolic curve from the EP of Hickory Street to the Horizon
Road entrance flow line. Water should not flow from Horizon Road across Hickory Street
during a 10 year storm event.
VirginiaDOT.org
WE KEEP VIRGINIA MOVING
4. UFO HH Box should not be inthesidewalk or within the maintenance area of the culvert
� I
QI
OF \
8'
8"
system.
5. Water valve boxes should not be in the sidewalk. /
6. Sanitary MH should not be in the
22'
TW
REMOVE
INSTALL
4"X4" TE
•I . I . un 1 \ nn . . I
sidewalk or CG-12 area.
7. CG-12 alignment appears awkward in this location and should be adjusted or moved to
meet ADA requirements:
8. Valve to £uehydrant'l should be moved from Curb into grass area.
FHA 6" GV
2fn
1
R2
R25'
8" GV
20'
For additional information, please contact Max Greene at 434-422-9894.
A VDOT Land Use Permit will be required prior to any work within the right-of-way. The
owner/developer must contact the Charlottesville Residency Transportation and Land Use