Loading...
HomeMy WebLinkAboutVA200000015 Review Comments 2000-08-01 STAFF PERSON: Jan Sprinkle PUBLIC HEARING: August 1, 2000 (Deferred from July 18, 2000) STAFF REPORT VA-00-15 (Revised) OWNER/APPLICANT: Ray A. Graham, Ill, owner; and, American Tower for Triton PCS TAX MAP/PARCEL: 07900-00-00-01000 (part) ZONING: RA, Rural Areas, and EC, Entrance Corridor ACREAGE: 40' x 40' lease area within approximately 25 acres of an 866.071 acre parcel LOCATION: The site is totally bounded by Interstate 64, Rt. 250 and Rt. 22 at Shadwell. INTRODUCTION: This item was deferred from July 18 due to an increase in the variance needed. {The legal ad was filed on June 20th advertising a 20-foot setback and on June 21st, we received a request from the applicant to change to 18 feet.} Since the application was not advertised for the 18 foot setback, it is being reheard. Staff has made the same recommendation, changing only the distance of the tower from 1-64 and the height (not part of this variance request). The revisions are highlighted in a bold font (while the original number is in parenthesis). This reduction of setback to 18 feet represents the distance that has already received approval from the Architectural Review Board. The proposed conditions of approval have been modified to what the Board of Zoning Appeals initially approved at the July meeting. TECHNICAL REQUEST AND EXPLANATION: The applicant requests relief from Section 10.4, Area and Bulk Regulations, Rural Areas district, which requires a front setback of 75 feet on a thoroughfare state road. A variance of 57 (55) feet is requested to allow construction of a wireless telecommunications facility consisting of a tower, an equipment cabinet and smaller accessory items. The fifty-foot wooden pole tower is proposed to be 18 (20) feet from the property line adjoining 1-64 while the other structures will be farther back but within the 40' x 40' lease area. [In addition to the underlying zoning district setbacks, Section 4.10.3.1 requires that a tower be setback a distance equal to its height. Although the Board of Zoning appeals can reduce the minimum primary structure setbacks required under Section 10.4, the additional setback required based on the height of the tower under Section 4.10.3.1 must be reviewed and acted upon by the Planning Commission. Should the PC fail to approve that reduction, the applicant could then choose to request a variance from that section. It will be reviewed as part of the special permit application. This is not before the BZA presently.] Variance Report, VA 00-15 2 August 1, 2000 RELEVANT HISTORY: SP 93-32 attempted to locate a retail antique, gifts, and crafts complex on this same portion of the parcel, but was deferred indefinitely. SP-00-18 is pending to allow another tower on the property if this variance is approved. PROPERTY DESCRIPTION AND QUALIFYING CONDITIONS: Case law in Virginia dictates that we view this portion of parcel 10 as an independent parcel due to its separation from the remainder of the acreage by State- or Federal- maintained roads. This portion of the parcel meets all requirements of the zoning ordinance. There is nothing about the size or shape or topography of this parcel to qualify it for a variance. There is no hardship as defined by the State Code. Siting a tower eighteen (twenty) feet from 1-64 will be a convenience for the applicant. The Board of Supervisors has recognized that siting towers is very difficult under current regulations. At their direction and with assistance from consultants, staff has worked to draft the Personal Wireless Service Facilities Policy. The Planning Commission has considered this draft at work sessions, has conducted a public hearing on the policy and has offered recommendations. A revised document incorporating those recommendations will be presented for approval to the Planning Commission on July 18, 2000. Once the Commission has completed its review of the policy, they will pass it on to the Board of Supervisors. The public hearing for adoption has not been scheduled at this time, but is imminent. If the manual is adopted as it is currently written, this type of tower would be a Tier I I tower (out of three tiers) and would require Planning Commission approval, but not a special permit from the Board of Supervisors. The proposed policy enables the Planning Commission to establish setbacks to locate wireless communication facilities. This type of request as proposed would not require any action of the Board of Zoning Appeals. On this portion of the larger parcel there are no improvements, but this acreage is included in the total that receives use value taxation for agricultural and forestal uses. With these uses and the availability of by-right residential uses, there is neither hardship approaching confiscation nor any unreasonable restriction of uses. APPLICANT'S JUSTIFICATION AND STAFF COMMENT: A review of the variance criteria provided by the applicant and comments by staff follows: Hardship The applicant comments that the variance is necessary because: • The actual distance of the proposed facility from the roadbed exceeds the height of the tower; • Siting farther back would hinder the applicant's efforts to shield the facility from view; • Siting farther back would significantly diminish the facility's effectiveness; C:IWINDOWSITEMPIVA2000-15.2.doc Variance Report, VA 00-15 3 August 1, 2000 • To provide coverage on 164, the tower must be relatively close to the road; and, • To minimize the visibility, the site must be within a grove of trees; As stated, staff acknowledges that siting towers in Albemarle County under our current ordinance is difficult. However, staff cannot identify any hardship as described under the Code of Virginia relating to granting a variance. Reasonable use already exists on the property. 1. The applicant has not provided evidence that the strict application of the ordinance would produce undue hardship. Uniqueness of Hardship The applicant notes: • The property is uniquely sited at the top of a hill in a small clearing surrounded by trees and vegetation on three sides, thus allowing a shorter tower to be effective and remain shielded; • There are no existing structures between the lot line and the proposed location that would be impacted by granting the variance. Staff agrees that tower siting has its own unique hardships, however, the hardship is one of the use—telecommunications towers—not of the parcel. There is no hardship related to the land that could be unique. This parcel has plenty of area available for a variety of uses without a variance. All rural area properties must abide by the setbacks of section 10.4. 2. The applicant has not provided evidence that such hardship is not shared generally by other properties in the same zoning district and the same vicinity. Impact on Character of the Area The applicant offers: • There are no other structures on adjacent properties that would be impacted; • The adjacent property is all owned by VDOT; and, • Dense vegetation and a steep grade leading down to the roadbed surround the site. Staff finds that locating a tower on this particular parcel may change the character of the surrounding rural historic district, if it is at all visible. The variance may make it easier for the Planning Commission and Board of Supervisors to permit a tower in an area that will insure the least possible visibility. 3. The applicant has provided evidence that the authorization of such variance will not be of substantial detriment to adjacent property and that the character of the district will not be changed by the granting of the variance. c:IWINDOWSITEMPIVA2000-15.2.doc Variance Report, VA 00-15 4 August 1, 2000 STAFF RECOMMENDATION: Since only one of the three criteria has been met, staff recommends denial. However, should the Board find cause to approve the request, staff recommends the following conditions: 1 . This variance is for the facility described in this file only. Any modification may require new variance review. 2. A tree conservation plan identifying all trees that have a diameter of six (6) inches or greater (measured at six (6) inches above ground) within 25 feet of the proposed tower site shall be prepared by the applicant and submitted with the building permit application for the tower. The plan should note any trees to be removed to make space for the tower and its appurtenances including the driveway. 3. The cutting of trees within 75 feet of the tower shall be limited to dead trees and trees of less than six (6) inches in diameter measured at six (6) inches above ground, except those trees identified on the plans as necessary for the establishment of the towers; 4. Removal of any remaining trees (or their limbs) shown on the plan is prohibited unless recommended by an arborist for the health of the tree or required by a public utility. C:1WI NDOWSI TEMPI VA2000-15.2.doc ZONING TRITON DOCUMENTS CV-R-336G UNION RUN TRITON PCS, INC. RAWLAND SITE AMEFiICAJV TOWER 9211 ARBORETUM PKWY NEW WOODEN POLE SUITE 200 RICHMOND VA 23236 (804)323-9500 (PH) (804) 323-1560 (FAX) 2989 EDGEHILL DRIVE CHARLOTTESVILLE , VA 22911 , INDEX C INC. SHT. NO. i I DESCRIPTION / I. T.T.Y. PARTICIPANTS I Ti I TITLE SHEET T.T.V. REP SIT RAP uIXE OE MET SCE INC t703(569-6600 DIRECTIONS TO SITE: ExiSTING 9U,LOiNL Cl I SITE SURVEY (BY OTHERS) //J/// SITE . RE SECURITY,COMMUNICATION & ELECTRICAL FROM R(CHLDNO TAKE 64 VEST TO EXIT 124. THEN TURN LEFT ONTO HIGHNAY 250 EAST. CO 2.1 NILES. ®RAW LAND 21 ELEVATION AM) SITE PLAN CDNST. REP GDAVE CLNNINGIAY HAIGHLANDERICAN TOYER 18041323-9500 TURN LEFT ONTO HIGHWAY 22 EAST. SITE (PRIVATE ROAD ACCESS) ON THE LEFT APPROX 1/4 MILE BEFORE SURVEYOR GARY FUGATE HIGHLAND (423)975-9239 6212 OLD COURT CITGO GAS STATION. .EXISTING ANTENNA TOYER RF ENC. SPRINOE (� Z2 I SITE DETAILS ZONING PH-( r7 r ❑EXISTING MATER TOYER F ax•L O / . I_ 2000142 \ (- TRITa APPROVAL: 8 WALLER S. 414-T11-7.)� ?VI: SIGNATURE1cDHsr. ucR.I PATE :::::::::: GATE vg SIGNATURE(RF EHGINEERIDATE DATE Ail ittiifiYAffiff it[ffifzfics. • '�'�_ \ , APPLICABLE CICES OWNERS APPROVAL UNION RUN IFllftll�k ilithtli.Si4l.l`4e_ax. , �J � _'`�,` \� RAW LAND SITE t;f liPttf`ititialfifififififi ►�•.` I +THE LIFE SrTETY CODE 1988 OR LATEST. NEW WOODEN POLE (WItijf 1B•ft2,S4pfj'¢f•xf i "+. .THE NATIONAL ELECTRICAL SAFETY CODE _tA{ A AAA A A;;-- ~��'..� (ANSI C-2. OR LATEST) SIGNATURE)OWNER'S AGENT) ::tiztzzzzzJ;ttt%==13' DATE 2989 EDGEHILL DRIVE �eA�rt-ree a THE N.E.C. 1999. IaT /r, CHARLOTTESVILLE, VA 22911 .�1_ s -oo ra'za.c u4 r. OmI C 4 t-w-OO FOR L rw w ne A e PROJECT SUMMARY 6.. aa.G 3 4-:-00 FOR La4.c nut. a, MC I •-IN-OH _ FOR La«c.,.K a MC -11 TAX PARCEL NO. 0T900-00-00-01000 JURISDICTION CHARLOLETTESVILLE. VA (ALBERMARLE( A-•-0 ron za.. +A�c. a. M MO (WC .ic�a.s St OW MY-a 1 ICIER OWNER TRITON CURRENT ZONING A-I A WI YG no TITLE DRAWING TITLE 4/!// // / DEED BOOK 329 LATITUDE 38'00'40.1 JJ" // PAGE 120 LONGITUDE T8.23'40.985" TITLE SHEET :1—.'%..17.:\, Q' mAp N/A ELEVATION 432.2' GROUND KAYO 1988 LOCATION PLAN PROPERTY OWNER RAT A GRAHAM II I DRAWING NUMBER T1 . ..\SCE\Triton Phase3\200014z dgn 06/23/00 02: 35:56 PM printhaf -.. ._ -'''rsC'.7. E.2.*:«�- '+...'... ^.i '- - . c ' r R N • .01.0S t,¢„aN ACCESSOF• 10PRIETARY INFORMATION • ASO UTILITY E/SEYENi F THE INFORMATION CONTAINEYD IN THIS ;,''n. r n)RE.ANYS USE 0 DI OSURE as ., OTHER THAN THAT WHICH RELATES TO TRITON,P.C.S.IS STRICTLY PROHIBITED. °K's _- _ DATE: 3-15-00 -;,....c, S��, _ a SCALE: 1"=40' GRAPHIC ICAIR �„ DRAWN: TLF /' RANT., 1` `- ! • Iai s � .,,`` :� CHECKED: GCF/LMC S REVISIONS: / Lt ` �, ON!W \\\ rl c DATE: / ; : - °�» iiI ACCESS ROAD 6-21-00 _ w -� � `\ 'WNW \\�-,'rr LOCATION MAP i' .w.ae Od 'U\ \\ N.T.S. O�/• /` \ \ • ,. `13.051.1W \`Q\/I+`\\\ acts 'fir \\• \F so, \ \ °,<'s�„ � ,z____' _ °�,P AMERICAN TOWER \ ams�"a':" aaHOF D x+Q--—==—�' L \ '� 9211 ARBORETUM PKWY a,A„` _\ \\ SUITE 200 \.Q\ TER RICHMOND, VA 23236 \N71.9j- S?tAT (804) 323-9500 (PH) 'Gu.Ar \ \ \ l F 64. (804) 323-1560 (FAX) /�?CXMATE lOGnoN OF "4 "Q PECPOSED 20'ACCESS \ -—/j�•r, ..N. - • 0uer.•',- AMC UTILITY EASEMENT "R" 'ate \ ` V maw DESCRIPTION CF PROPOSED 40' X 40' LEASE PARCEL .,-... j \ar Amman mimme BECNNINC AT A POINT.SNO POINT BONG LOCATED N 75"53.29 NLOI,' E-36.11' wA"� N 7 ♦•v tIU1MIRE3NeR'S♦ Y I FROM THE CENTER OF A PROPOSED WOOOEN POLE.THENCE WITH A NEVI .Nutr...7a�LEA. LINE THE FOLLOWI NG FOUR CJvl15: e.mm a.1o..11P..r fl*C TNTY'-IA• /1C1 I A I 1 5 7545'05'W-AO.00' (\VIIL/VJI \VI(Iv 2 N 75♦9'06'W-40.00' �a a�CI 3 N 1♦•t0.5♦•E-40.00' grata•.M MN •.m 7 ♦ S 75'49'06'E-40.0Y ®,0•313 �• TO THE POINT OF BECNNINC AND CONTNNNC 1600 SOUARE FEET. 11 SECURITY,COHNUNICATION 6 ELECTRICAL 6212 OLD KEENE MILL COURT SPRINGFIELD. VIRGINIA 22152 I m PH,C703)569-6600 FAX,C703)569-2550 • OWNER: RAY A. GRAHAM III SURVEY BY: 29DRIVE CHAROLETTESV BLLE E9OVAE(ALBERMARLE COUNTY) HIGHLANDS DEED BOOK 714 PAGE 406 SURVEYING INC. TAX PARCEL NUMBER 07900-00-00-01000 1 ZONED A-1 802 BUFFALO STREET SUITE 7D JOHNSON CITY,TN. 37604 PHONE: 423-975-9239 . FAX:423-975-9249 rr, CALL BEFORE DIGGING a,M MISS UTILITY ems,,,, 4‘.\ 1-800-552-7001 ` \ \.a.e OM.rows NOTES: S SHEET 11TLF THE CONTRACTOR SHML CONTACT THE PROPERTY OWNER PROR TO \ — 7:4r' — SITE SURVEY ANY MORN ARO 5NALL PROMOS THE.PROPERTY OWNER NTO.A WORK y' A-/r ` _ SCHEDULE.CONTACT PERSON.ANO THE CONTRACTORS PHONE NUMBER `.•6T V TE LOCATION OF UnUnES MO U+OERGROUNO STRUCTURES SHOWN \� '2� SITE NAME: UNION HILL ARE APPROKWTE ANO THOSE SHOWN ARC NCR NEOWARILY ALL OF `tea. '.W� 29/39 THE EIasT No ummEs ANo sTRuc ruREs rr a THE COMTRAc^oRs SITE ADDRESS: o ARLOTOT S�VILLE VA DOSTENSBUTY TO OETERES A THE DtACTDERG LOCATION ANC THE .a[E c+a ALBERMAFILE CCUFITY OOSTFNCE OF ALL UILJOES AND UNDERGROUND STMICTURE. SITE NUMBER: CV-R-33&-G `JRERIOR PROPERTY LINES 9FMING ANO DISTANCES ALONG THEN ARE TAKEN FROM OEMINFORMAION AN0 ARE NOT FLC.0 SUKYEIED. TIPS MAP NOT TO BE USED FOR CONSTRUCTION PURPOSES. SHEET NUMBER C 1 I I. SITE WORK GENERAL NOTES: ' ....... '1111 ''1 I. IUBSISN. STUDS.DEBRIS.STICKS. STONES MO OTHER REFUSE SHALL a. PROPOSED ') 1 S REMOVED FROM TIE SITE ONO DISPOSED OF LEGALLY. c� 20' WIDE GRAVEL ACCESS2. A AYSIF�N TIELTRIT GRADED TO CAUSE OI EOUIPIENT AMO POLE�AAEATER 10 FLOWSHALL BEAL VArOOiI ECTOROME r 3. FILL l E►6 CROM. FROZENWRIALSSNIO�if OR ICE SHALL BE PLACEDIN 4 �` PRESENTED TO ANT FILL O(E16ANKIENT. j' /. THE SUBGRAOE SHALL BE COMPACTED AND BROUONT TO A SMOOTH rl' UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. • PROPOSED 40' X /0' 5. ALL EXISTING ACTIVE SEWER. WATER. GAS. ELECTRIC. AND OTHER ' LEASE PARCEL. SEE UTILITIES WERE ENCOUNTERED IN THE oft. SHALL BE PROTECTED ENLARGED SITE PLAN 11 a AT ALL 11MES. AND WHERE REOUIREO FOR THE PROPER EXECUTION Of R� j THIS SHEET THE VO(K. SHALL BE RELOCATED AS DIRECTED BY THE ENGINEERS. 7E vl EXTREIE CAUTION SHOULD 8E USED BY THE CONTRACTOR WHEN EXCAVATING OR PIER DRILLING ARCUNO OR PEAR UTILITIES. ?Sp "--- ... .. _ - INTERS) COUNTY OF ALSEMARLE CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. ATE R. THE CONTRACTOR SHALL MATE NECESSARY PROVISIONS TO PROTECT 64 EXISTING IIPROVEIENTS. EASEMENTS. PAVING. CURBING. ETC. INRCONAITRUCTIO U THCO LETIOTT CF KAY OCCURREDK. TNHE EE CO CONTRACTOR LullCONSTRUCTION ON OR ABOUT THE PROPERTY. I \"7.r, - ~'/ ANTENNA ELEVATION TRITON PCS, INC. '.f NOT TO SCALE TRUE NORTH TRITON ANTENNAS. PROVIDE SUPPORTING AMERICAN TOWER PLATFORM AND STRUCTURE AS SUPPLIED BY TOWER (59 KEY PLAN 0 - MANUFACTURER. DESIGNED IN ACCORDANCE WITH EIA/TIA 9211 ARBORETUM PKWY STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWERS NO1 TO SCALE 300' 100' d ANTENNA SUPPORTING STRUCTURES. EIA/TIA-222{. SUITE 200 % AND BOCA NATIONAL BUILDING CODE. 1993. WITH VIRGINIA RICHMOND VA 23236 200' / STATE BUILDING CODE REOUIREIENTS (WINO VELOCITY (804)323-9500 (PH) 90 MPH) CONNECT ANTENNA SUPPORTS TO TOWER AS (804)323-1560 (FAX) !I DETAILED BY MANUFACTURER. TOWER MANUFACTURER ANO OWNER TO VERIFY THAT NEW ANTENNAS AND SUPPORTS ARE IN ACCORDANCE WITH ORIGINAL EXISTING TOWER AND FOUNDATION DESIGNS. RESPECTIVELY. FENCE LINE TOP OF NEW _ XISTING 30' �WOOOEN POLE �, —•FLUSH EIOUNTD 141011INNNN",.. ITON DAR TREE O —�`,-poowke 3 pol a EL. 182.2' ______ ANTENNAS. SEE EXISTING 52' 3 ANTENNA ELEVATION CEDAR TREE N EXISTING IT' / �` C '^ C. CHERRY TREE ~ - THIS SHEET ' V _ NEWPTRET _`�. '�--- Stsr. f—NEW TRITON , J --/ \•_ A-,` aZ TEL POLEWOOOEN PROPOSED v EXISTING WIDE f FENCE LINE �� yCPOLE # C-5-27 GRR SS ` J '/ SECURITY,COMKIUNK AiION L• ELECTRICAL /:111.1:, SPR OL T OAD / .! SPR �'1�./ 1 FENCEILINE FNG N( - 550 EXISTING /0 <, TN O/C "OPOSEO I` CEDAR TREE _ TRITON 50' r000EN PROPOSED 2-2"CONDUIT ! POLE 1' ! < !"200014Z • 36' BELOW FINISHED GRADE j/Ill, PROPOSED TRITON I z < FOR POWER AND TELCO (LUSH MOr ANTENNA (TY 11' i' Q �..__ 25 c RDPasEo rRITaN WALLER S. 'f • t� III PROPOSED"`--.___• COAXIAL CABLES / • EXISTING 43' N$ ` ,;, �� 00 TELCONEW POWER/ 7'-2. UP POLE VIA UNISTRU CEDAR TREE W AS„ (TVA) POLEx l (TYPI �� AND CLIP ASSEM3UE NEWPRWLAANDSCAPING. .SEDD° = c EXTEND NEWIDLANDSCAPING TO PROPOSED 1 \ r ¢ •S EXISTING III_ ...._....„. 8 . 1.. TRITON L -C` TREE LINE I O\-„...,..._,...... _. . ICEBRIDGE ,, Tl PROPOSED TEL 5 1 7. ' •ROPOSED ' IO ON RUN METER AND SERVICE �! I -6' , �; FITS TRITON CEDAR TREE �� P4W T LAND SITE DISCONNECT ON H{RATE V ( : BTS CABINET EXISTING 10' . , PROPOSED PROPOSED TRITON NEW WOODEN POLE �n ES 22'-6' ,' LEASE 40'40' X �UPAPOLE VXIAL IALUNISTRUT VE ID® EXISTING 48' / I' CHAR OT T ESVILLE,VA� I 22911 CEDAR TREE PARCEL AND CLIP ASSEu8LIE5 1 ' LANISCAPING NOTES: -PLANTS ARE TO BE 12" BAYBERRIES ANO 24' ILEX OPACA COO ' PROPOSED TRITON 10'-0" X 12'-0' CONC.PAO ' HOLIES ARRANGED IN DOUBLE STAGGERED ROWS. S a�•oo ra zo.c rout R MO-A4 ADDITIONAL SINGLE ROW OF PINE (PSI SHALL BE WITH TURNED-0OWN EDGE. CONCRETE • �•woD FM zaT.c rwt ow MC BE TINTED BROWN EARTH-TONE. PLANTED SURROUNDING THE PROPOSED TELECORP POWER/ SEE CONCRETE EOUIPIENT PAD DETAIL TELCO POLE AND TWO ADDITIONAL TREES AS INDICATED ON PLAN. .1 .w.DD TOT zac. row._ Coor+c IEXISTING SHEET Z2 TESE PINE TREES (UST BE A MIN. 6' 0 TALL AT TINE OF PLANTING z •-m•oo rdT ztrc Trot w-S,YBERRIES IN PLAN REPRESENTED (BAYI ANO OPACA PROPOSED PROPOSED EXISTING 38' ' CEDAR TREE o HLLl1ES (10) -PLANTS TO BE SPACED AT MIN 6'-0' ON CENTER. TRITON TRITON ' °'K'°° r°"z°r.c REVIEW °" MC CEDAR TREE - TAKE NECESSARY PRECAUTIONS NOT TO DISTURB EXISTING ICEBRIDGE BTS CABINET w. DATE Rv6pTS sY CM a►a Vi GE TATION. ' -COORDINATE WITH TRITON CONSTRUCTION MANAGER AND SCALE.AS s.nw.1 iir- LINER FOR TOTAL GROUND COVER. EXACT LOCATION ANO PROPOSED DRAWING TITLE EXISTING EYACT AMOUNT OF SHRUBS TO BE PURCHASED. TRITON TREE LINE 1 '-PAX 12,-O' ELEVATION GRADE AT CENTER OF TOWER & SITE PLAN [ $EL.432.2' ♦ ♦ '9 Fl1�1 2 I NORTH NI�A1IG�D SITE PLAND3 RI ' POLE ELEVATION ORAWG NUTABER • 100' NOT TO SCALE 200' Z 1 . .\SCE\Triton Phase3\200014z.dgn 06/23/00 02:36:08 PM printhaf f _ i • • EOUIPIENT CABINET SHALL BE BROWN EARTH-TONE J-BOLTS TO 2'-0" ACCOIOOATE STEEL TROWEL FINISH FOLLOWED PART aB5O1 BY LIGHT BROOM FINISH. SLOPE TO DRAIN AWAY FROM NEW d FUTURE K7010' E.K.. LONG CABINETS. LEVEL UNDER CABINETS ri BARS ON TOP ' B MIL POLYETHYLENE CONC• 26 DAr CCMRESStONVAPOR BARRIER STRENGTH OF 7000 PSI. SS AIR• PIPE HEAD ENTRAINMENT d MAX. 3" SLUMI a3/4 ' CHAMFER BY MI413509 CT PART ++8509 .I `rI ' POKER 1� __ .� �. c s. •. PEDESTAL = _ "I y 11iii 3 1/3" GRADE TO GRAIN m wig '�:�?�+ ,^' PIPE COLUMN AROUND PAD ''� -• - BT MICROFLECT - - J!r '_ l_ _='�T`�-.'- - - a am 00.'n PART +6130 BACKFGRADE II PERIMETER WITH - - a v00T TYPE I SELECT - - MATERIAL COMPACTED TO • o 95%MAX. DENSITY 3" P 0 ... / T. :4e12" CL,J ., EXCAVATE TO STABLE SLOPE TRITON PCS, INC. CONCRETE 3O4 CONT. W/ 12• I AMERICAN TOWER FOUNDATION fgrHOOK AROUND CORNERS COMPACTED SUBGRaOE—� t � �;� j j% TURNEDOXALL EDOEDGE B' COMPACTED VOOT 21A AGGREGATE—� S9211 UIT ARBORETUM pp ETUM PKWY ► (804) �2 9500 Ph) (804)323-1560 (FAX) 3. � � CONCRETE EQUIPMENT PAD DETAIL NOT TO SCALE 1 -0' + 1" CHAO-ER %TES: e 35' (TYP) 1. ALL SITE GRADING. EARTHWORK. AGGREGATE SEA BASE. PAVEIENT , REPAIR &SEEDING AND$COOING SHALL BE IN ACCORDANCE WITH INC. �. ICEBRIDGE DETAIL • THE APPLICABLETIONS PERCEPT OF VIRGINIA T CF TRANSPORTATION (VOOi) ' \V/ SPECIFICATIONS. EXCEPT AS OTHERWISE INDICATED. SPREAD TOPSOIL. STOCKPILED FROM BEFORE EXCAVATION OR NEC TO MINIMAL 6"DEPTH. / NOT TO SCALE • —CABINET TO SIT FLUSH 10'-0" X 12'-0" CONC.PAD - WITH CHAMFERED EGOE UNPAVED LEVEL AREAS. REPAIR ALL DISTURBED PAVEIENTS ANO OTHER / WITH TURNED-DOWN OF CONCRETE PAD SITE FEATURES TO MATCH EXISTING. EDGE. SEE CONCRETE • • EQUIPMENT PAD DETAIL • . - 2. ALL CONCRETE PORK SHALL BE IN ACCORDANCE WITH ACI 318-9S AND THIS SHEET ACI 318 R-95. BUILDING CODE REOUIREIENTS FOR STRUCTURAL CONCRETE SECURITY,COMMUNICAT}ON o ELECTRICAL AND COMIENTARY Me ACI 301-89 SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS. USING CONCRETE WITH f'c.1000 PSI ANO 6212 OLD URT SPRIN F • 3. CONCRETE SHALL BE TINTED BROWN EARTH-TONE. PH`( 5.. O RBS AXONOMETRIC VIEW 200014Z ] FL �,{/_ _ (ONE CABINET SHOWN ON PARTIAL CONCRETE) — Y T NOT TO SCALE / 12'-0" �PROPOSED TRITON I WALLER S 'ter COAXIAL CABLES UP POLE VIA UNISTRUT • , AND CLIP ASSEL€LIES • PROPOSED CONCRETE PAD TRITON • ICEBRIDGE PROPOSED PROPOSED TRITON NEW TITON I----I---- 1 COAXIAL CABLES — Wiiiii 66' WOODEN ROUTED TO NVAC POLE CABINET UNITS UNION RUN RAW LAND SITE 5,-0" NEW WOODEN POLE 2989 EDGEHILL DRIVE TOP of AND CABINET CHARLOTTESVILLE, VA 22911 0 S 4-13-0o FOIL$O.•c r«AL OP F.0 B'-0' ELECIRICLLJ a .-..-oo !OR 20,44 r.,, Dm PRC MIN. PROPOSED PANEL . TRITON 3 ••.-ao rO•ZO..c rya, w nO BTS CABINET z •-O>'-Oo FO•zO.•.0 row. Ow PRC . o-%-OO !PI 20.••G RCK• Om PRO FINISHED f ^ GRADE w. OATc RLVOOmI .Y w APP•0 �r_��1 1 l-�� ILJ.'-._-= r T ' s DRAWING TITLE -I _i ii_i iai _ I I I __ 1 CONaETE►Aa PROPOSED TRITON , SITE DETAIL CONC.PAD CONCRETE PAD & ICEBRIDGE DETAIL EQUIPMENT LAYOUT PLAN DRAwNG NuuBER NOT TO SCALE NOT TO SCALE Z2 .. .\SCE\Triton Phase3\200014z.dgn 06/23/00 02'36.20 PM prsnthaf