Loading...
HomeMy WebLinkAboutSUB202100179 Plan - Other (not approved) 2022-01-25ie � it '. ie i� � •� 6 DRAWING INDEX Sheet 1 Site Plan 2 General Notes/ Design Parameters 3-4 SRW Details 5-6 Wall A - Ste. 0 to Sta. 300 7 Wall B - Sta. 0 to Sta. 54 8 - 10 Wall C - Sta. 0 to Ste. 429 11 Wall D - Sta. 0 to Ste. 159 12 Wall E - Sta. 0 to Sta. 54 N E W )( S �Ar A fA , a SITE PLAN "Z" I Ste. 300 LOT _ r Sta.0 WALL A 1 v;� ; , Ste. 54, ,E�'� /�" O a Sta_WALL B 17 a ALI- fn -•: y - , ov,a •�w �+ n ,A p y M • r/, testa o r WALL D Anchor Diamond Pro Segmental Retaining Walls Galaxie Farm Albemarle County, Virginia Site Plan Adapted From the Grading & Drainage Plan, Sheet No. C8 and Sheet No. 9, Dated October 1, 2021 (Rev. 12/28/21), Prepared By Collins Engineering. Site Plan For Illustrative Purpose. Approx. Scale: 1" = 100 FT Scale: I" = 100 FT 0 50 100 / Circeo 5956 Buckland Mill Road Geotechnical Roanoke, Virginia 24019 MICHAEL R. CI Engineering, P.C. 9 No. 021245 ® Phone: (540) 366-2379 Scal¢: 1"=100 FT Project No. RW-2740 SS+ONAL EAU Date: 01/25/22 Revision: --- Sheet 1 of 12 NOTES: 1.0 STRIP VEGETATIVE AND ORGANIC SOIL FROM THE WALL AND GEOGRID ALIGNMENT. 2.0 BENCH CUT ALL EXCAVATED SLOPES. 3.0 DO NOT EXCAVATE BEYOND EXCAVATION LINES SHOWN ON PLAN UNLESS DIRECTED BY THE GEOTECHNICAL ENGINEER TO REMOVE UNSUITABLE SOIL. 4.0 CONTRACTOR SHALL ENSURE TEMPORARY EXCAVATIONS ARE STABLE AND PROVIDE EXCAVATION SUPPORT IF NEEDED. 5.0 GEOTECHNICAL ENGINEER SHALL VERIFY FOUNDATION SOILS AS BEING COMPETENT PER THE DESIGN PARAMETERS. 6.0 LEVELING PAD SHALL CONSIST OF COMPACTED SAND, GRAVEL, OR COMBINATION AND SHALL BE A MINIMUM 6-INCH THICK LAYER WITH A MINIMUM WIDTH OF 24 INCHES. 7.0 A 4-INCH-DIAMETER SLOTTED DRAINAGE PIPE SHALL BE INSTALLED BEHIND THE WALL AND CONNECT TO WEEPHOLES INSTALLED AT THE BASE OF THE WALL (40 FEET ON CENTER) AND EXTEND BEYOND THE FINAL GRADE TO DAYLIGHT (SEE DRAIN DETAIL). 8.0 DRAINAGE AGGREGATE AND UNIT (CORE) FILL SHALL CONSIST OF CLEAN ANGULAR GRAVEL (VDOT NO.57 STONE), MEETING THE FOLLOWING GRADATION AS DETERMINED IN ACCORDANCE WITH ASTM D-422. SIEVE SIZE PERCENTAGEPA55ING 1-112 INCH 100 1 INCH 95-100 1/2 INCH 25 - 60 NO.4 0-10 NO. 8 0-5 9.0 GEOGRIDS SHALL BE LAID HORIZONTALLY ON COMPACTED BACKFILL FOR THE REQUIRED GEOGRID LENGTH (GL) IN THE TENSILE STRENGTH DIRECTION (PERPENDICULAR TO WALL FACE) NOTED ON THE WALL PROFILE. THE GEOGRID SHALL BE PLACED WITHIN ONE INCH OF THE FRONT FACE OF THE UNIT BELOW AND EXTEND HORIZONTALLY OVER COMPACTED FILL. 10.0 ANCHOR DIAMOND PRO UNITS MOLDED DIMENSIONS SHALL BE 8 INCHES HIGH BY 18 INCHES LONG BY 12 INCHES DEEP AND SHALL NOT DIFFER MORE THAN + 1/8 INCH IN ANY DIMENSION. 11.0 A 1-INCH SETBACK PER UNIT (REAR LIP) SHALL BE MAINTAINED FOR PROPER BATTER (I.E. 7 DEGREE CANT FROM VERTICAL). 12.0 GEOGRIDS SHALL BE PLACED WITHIN 1 INCH OF THE FRONT FACE OF THE UNITS AND GEOGRID5 PULLED TIGHT (AFTER PLACEMENT OF THE NEXT COURSE OF BLOCK UNITS) TO REMOVE SLACK AND TO INTEGRATE GEOGRIDS AND UNITS. 13.0 FIELD ADJUSTMENTS OF BLOCK ALIGNMENT MAY BE MADE ON NON -REINFORCEMENT LAYERS WITH THE USE OF SHIMS OR ASPHALT SHINGLES TO RAISE ONE COURSE OF BLOCK BY A MAXIMUM OF 1/4 INCH VERTICAL HEIGHT. 14.0 REINFORCED FILL SHALL CONSIST OF GRANULAR SOIL FILL WITH U5C5 SOIL TYPES GP, GW, GM, &C, 5W, SP, SM OR 5C WITH A MINIMUM ANGLE OF INTERNAL FRICTION, OF 28 DEGREES AS OUTLINED IN DESIGN PARAMETERS - NOTE 5. LOW PLASTICITY CLAYEY SAND (SC), SILT OR CLAY (ML-CL) CAN BE USED SUBJECT TO APPROVAL BY THE GEOTECHNICAL ENGINEER. MAXIMUM PARTICLE SHALL BE LIMITED TO 4INCHES IN DIAMETER. THE FINE FRACTION (MINUS NO. 40 SIEVE) SHALL HAVE A MAXIMUM LIQUID LIMIT (LL) OF 40 AND A MAXIMUM PLASTICITY INDEX (PI) OF 20. THE BACKFILL SHALL BE FREE OF DEBRIS AND ORGANIC MATTER. HIGHLY EXPANSIVE SOILS (MH-CH) SHALL NOT BE USED IN THE REINFORCED FILL ZONE. 15.0 REINFORCED FILL SHALL BE PLACED IN 8-INCH LIFTS AND COMPACTED TO A MINIMUM OF 95% OF MAXIMUM STANDARD PROCTOR DENSITY (A5TM D-698) AND WITHIN + 3 PERCENTAGE POINTS OF OPTIMUM MOISTURE CONTENT. COMPACTION TESTS SHALL BE PERFORMED AS THE WALL IS INSTALLED. COMPACTION WITHIN 3 FEET OF THE WALL SHALL BE LIMITED TO HAND -OPERATED EQUIPMENT. DESIGN PARAMETERS: 1 BUILDING CODES: 2015 VIRGINIA UNIFORM STATEWIDE BUILDING CODE (USBC) AND 2015 INTERNATIONAL BUILDING CODE (IBC). 2 THE WALL PROFILES ARE BASED ON THE GRADING & DRAINAGE PLAN, SHEET NO. C8 AND SHEET NO.9, DATED OCTOBER 1, 2021 (REV. 12/28/21), PREPARED BY COLLINS ENGINEERING. 3 WALL DETAILS SHOWN ON THIS PLAN ARE FOR ANCHOR DIAMOND PRO SEGMENTAL RETAINING WALL (SRW) UNITS MEETING THE NATIONAL CONCRETE MASONRY ASSOCIATION (NCMA) CRITERIA FOR SRW WALL SYSTEMS. 4 ENGINEERING ANALYSIS BASED ON USE OF STRATAGRID 5GU60 GEOGRID. OTHER COMPATIBLE GEOGRIDS MAY BE SUBSTITUTED WITH THE APPROVAL OF THE WALL DESIGN ENGINEER. 5 THE DESIGN OF THE SEGMENTAL RETAINING WALL (SRW) ASSUMES THE FOLLOWING PARAMETERS: Ym, Moist FRICTION SOIL SOIL UNIT WEIGHT ANGLE COHESION CONDITIONS Type (PCF) (DEG) (PSF) REINFORCED FILL Granular Soil 120 28 0 RETAINED SOIL Sandy SILT 120 28 0 FOUNDATION SOIL Sandy SILT 120 28 100 16.0 A VIBRATORY PLATE TAMPER SHALL BE USED TO DEN5IFY NO.57 STONE. COMPACTION TESTS CAN BE WAIVED WHERE NO.57 STONE IS USED AS REINFORCED FILL. 17.0 CONTRACTOR SHALL SLOPE SITE GRADES TO DIRECT SURFACE RUNOFF AWAY FROM WALL AT END OF EACH DAY TO AVOID WATER DAMAGING THE WALL WHILE UNDER CONSTRUCTION. 18.0 ANY SURFACE DRAINAGE FEATURES, FINISH GRADING, PAVEMENT, OR TURF SHALL BE INSTALLED IMMEDIATELY AFTER THE WALL IS COMPLETED. 19.0 IF SITE AND SOIL CONDITIONS, WALL GEOMETRY, OR WALL LOADING ARE DIFFERENT THAN THE DRAWINGS AND THE DESIGN PARAMETERS, THE CONTRACTOR MUST CONTACT THE WALL DESIGN ENGINEER PRIOR TO PROCEEDING WITH THE CONSTRUCTION OF THE WALL. 20.0 DETAIL FOR PEDESTRIAN GUARD POSTS AT THE TOP OF THE WALL IS PROVIDED FOR PLACEMENT OF POSTS BEHIND THE WALL. 1" Setback )pen Cells Filled With Stone) 1" Rear Lip UNIT CONNECTION DETAIL (Not to Scale) 6 SOIL STRENGTH PARAMETERS ARE BASED ON USE OF GRANULAR OR LOW PLASTICITY SOIL IN THE REINFORCED FILL ZONE. ALL ENGINEERED FILL SHALL BE PLACED IN MAXIMUM 8-INCH LIFTS AND EACH LIFT I5 COMPACTED TO A MINIMUM OF 95% OF MAX. STANDARD PROCTOR DENSITY, AND WITHIN+ 3 PERCENTAGE POINTS OF OPTIMUM MOISTURE CONTENT, USING PORTABLE COMPACTION EQUIPMENT. DO NOT USE HIGH PLASTICITY CLAY (CH-MH), ROOTS OR TOPSOIL IN REINFORCE ZONE. ANY SOFT, SATURATED SOIL ENCOUNTERED IN 5UBGRADE SHALL BE UNDERCUT AND REPLACED WITH CRUSHED STONE TO STABILIZE THE FOUNDATION 5UBGRADE OR AS DIRECTED BY THE GEOTECHNICAL ENGINEER. WALL A - MAX. WALL HEIGHT = 9.33 FEET (INCLUDING EMBEDMENT) WALL B - MAX. WALL HEIGHT = 5.33 FEET (INCLUDING EMBEDMENT) WALL C - MAX. WALL HEIGHT = 7.33 FEET (INCLUDING EMBEDMENT) WALL D - MAX. WALL HEIGHT = 4 FEET (INCLUDING EMBEDMENT) WALL E - MAX. WALL HEIGHT = 5.33 FEET (INCLUDING EMBEDMENT) FRONT SLOPE = LEVEL TO MAX. 31HAV BACKSLOPE BEHIND THE WALL = LEVEL TO MAX. 3H:1V EQUIVALENT BUILDING SURCHARGE AT TOP OF WALL = 350 PSF PEDESTRIAN SURCHARGE AT TOP OF WALL = 100 PSF WHERE APPLICABLE MIN FACTOR OF SAFETY (SLIDING) = 1.5 MIN FACTOR OF SAFETY (OVERTURNING) = 2.0 MIN FACTOR OF SAFETY (BEARING CAPACITY) = 2.0 DESIGN SOIL BEARING PRESSURE = 1,500 P5F MICHAEL R. CIRC5 NJ. 021245 Albemarle i Circe0 Geotechnical Engineering, P.0 FA Scale: N/A Date: 01/25/22 Revision: --- Virginia 5956 Buckland Mill Road Roanoke, Virginia 24019 Phone:(540) 366-2379 Project No. I RW-2740 42" Tall Pedestrian Guard —\ w/ Sleeve -It Fence -Post Anchoring System, Typ. 6'-0" O.C. Post Spacing :strion Guard Note: handrail/fence post has been designed for a 200 Ibs concentrated horizontal load ig at the top of the post with a factor of safety of 1.5 againt overturning. railing shall be designed for 50 Ibs per linear foot uniform load. railing design is not included in the engineering, but the forces applied to the railing been considered in the wall design Sleeve -It SDI Fence -Post Anchor System Note: Shrubs can be planted behind the wall. The top geogrid layer can be cut using a utility knife for placement of the root bulbs. r Reinforced Fillr Min 12" Thick VDOT No. 57 Stone Start Geogrid Approx. 1" From Front of Units - SRW Unit GEOGRID PLACEMENT DETAIL (Not to Scale) Sleeve -It SDI Fence -Post Anchor System - Top Dia. 7.4" Grout Fill After Post Installation w/ Min 3.000 psi Grout Bottom Dia. 9.4" Filter Fabric - 4 FT Wide Mirofi 140N or Equivalent ,—cantilever Base 30.61 x 15.3"W III � IIIRetained Soil mil III •.i3.ii3.ii3J III SLEEVE -IT FENCE POST DETAIL (Not to Scale) Min 42" Toll Handrail or Fence Post Center of Post Min 24" Behind Top of Wall, Max. 8'-0" O.C. Post Spacing Cop unit _ Secure to Top w/ Concrete A Min 8" Dia. Sleeve or Tube Form Fill Grout Around Post Cut Geogrid Around Sleeve or Tube Form 24" Min Non -Woven Filter Fabric 4 FT Wide 24"Min 8" Dia. Reinforced Fill HANDRAIL POST DETAIL (Not to Scale) Reinforced Fill 4 Dia. Perforated Drain Pipe 12" Thick VDOT No. 57 Stone .i. . .i. . .i. 00110o�'oolloolloo MICHAEL R. CIRC9 Mo. 021245 �l2S�ZZ '°_S+"ONAL El j 5/8" W r L Anchor Diamond Pro Units Wall Drain Pro (Weephole) at Max. 40' O.C. Drain to Daylight WALL DRAIN PRO DETAIL (Not to Scale) Circeo 5956 Buckland Mill Road Geotechnical Virginia 24019 Roanoke, Vir Engineering, P.C. 9 Phone:(540) 366-2379 Project No. I RW-2740 WALL A 516 514 512 510 0 508 506 t w} 504 � ... 0 502 500 498 W 496 S } 494 492 490 488 486 42" Toll Pedestrian Guard �rr�.rrrrrr.�rrrr,�rrrr • � � � rr■.rrr.�rrrru rr■.rrru�rrrr. • � � � rr■.rrrrrrrri� • � � rr■.rr �rrrrrrrrr.■rrrr esem7s����a.-i��Iri�`■ii�i�����i�����rri rrrr■.rrrrrrrrrrrr.■rrrrrr■ rirr■�irrrrrrrrrrrr.irrrir■ rrr■.rrrrrrrrrrrr.■rrrrrr■� rrr■lrrrrrirrrirrr■rrrrrr■ ��Lii`��������rrrr.■rrrrr�•�-- ri L Proposed Grade at Bottom of Wall BOW = 494.00 (LP) Drain Pipe to Daylight - 40 FT O.C. (Typical) I tl TOC = 504.33 TOW = 504.00 6" Thick Stone BOW = 496.00 Leveling Pad - rrr..rrrr • •: • � . � � rrr■.rrrl. rrr--------- =� Zr.■r rrrr r■MEMO Err ■.■. MEMO r■.r� - MEMO �.■.■.■! �■. �■.!■� ____ rya ---lr.rrra.:.■■■s�aasi�r■a r_ r_"- illeiM MM .r■z==Ez�I'Icz .rrrrrr.■rr rrrrarm .rrrrr■r rrr�rrrrrrrrnl■.■I rrrirr■■■.■.rrrrrrt r■r.rrrr N r® 120 130 140 150 160 170 180 190 200 210 222 230 240 I Station (ft) I I I as GL=6FT I� GL=7.5FT —I WALL A 516 - '�tQ" TOC = 508.33 (High Point) Tall Peclestri n uard TOC 508.33 (High Point) urrri.r.■ri.rrri.■rrri rrrr ���� ��!■� ���■� r■r�—���� • •. rrrr rrrrrr.■r rrru r■.rr/ •-----'-----'----'-----rrrrrrrrrr.■rrrr��r■.rrr.��r ------------- 0 rr�i�irr•1Cii�r�r�iYe®■■i■.■ r^rMr�rI■■Ir�rr�irri�rr�rr r o�r`f v aci CL 8 FT 1Irrri ,���rirr��rrrr^�rl■■Irr��rrri��rirr��r�rrA�rl■■Irr��rrri��riir+�rirr��rrrr�.rr■■■ irr�rrrr��ri��rir��rirr�rr■�.r6�r�..rdr��r!6 • .• = 00 6" Thick Stone 494 Leveling Pad 492 •, :• 67 Proposed Gradeat Bottom 1 , :• W 498.67 • 486 ■ ■ ■ ■ brain • 1' to Daylight O.C. (Typical) ., 250 260 270 280 ® 11 LEGEND ® Cap Unit (4" Height) 0 Anchor Diamond Pro Units (8" Height x 18" Width) Leveling Pad (Min. 6" Thick x 24" Wided Crushed Stone) TOC Top of Cap Unit TOW Top of Wall (Excluding Cap Unit) BOW Bottom of Wall (including Embedment) 60 ' — ' StratoGrid SGU60 Use Granular or Low Plasticity Soil in Reinforced Fill Zone RETAINING WALL A Sta. 120 to Sta. 300 Viewed From Front Face of Wall Farm Albemarle iew�x Circeo 5956 Buekland Mill Road Geotechnical Engineering, P.C. Roanoke, Virginia 24019 Phone: (540) 366-2379 No. OU245 �l2S�ZZ H1" : = 10 ft. iFSa_.. _ ef. Scald: V: 1"= 10 ft. Project No. I RW-2740 GL 0 4" Drain Pipe to [Design Soil Bearing Pressure = 1,500 WALL B 494 492 490 488 486 O } 484 .�"... 482 O in o 480 t � 478 m 01 W 476 474 t 472 in470 468 466 4641 0 GL=4.5FT I I -----• ME • : r 4 �������ME 0--� �--tee— Proposed .. - at Bottom of Wall GL = 4.5 FT 6L = 6 FT I I BOW = 476.00 = 478.67 , I� ❑g 20 I I GL=6FT 6L=6 FT 6" Thick Stone Leveling Pad BOW = 474.00 (Low Point) 30 [ Station (ft) GL=6FT 42" Tall Pedestrian Guard BOW = 474.00 (LP) - BfF���\\ 42 50 5q I / O� �Ap.9P`9- O---- -/ ��00 - ►1f 6L = 4.5 FT it - Sta. a Emma WALL B w/ 42" Tall Pedestrian Guard Where Specified pr ENLARGED SITE PLAN oo Sta. 40 00 Is ---�� Q L SScale: 1" = 20 FT \- o Io 20 LEGEND Galaxie Farm Use Granular or Low Plasticity SoilAj yji O� Albemarle County, Virginia ® Cap Unit (4" Height) CIRCEO GEOTECH in Reinforced Fill Zone Anchor Diamond Pro Units (8" Height x 18" Width) Circeo i�/�""r 5956 Buckland Mill Road — Geotechnical Leveling Pad (Min. 6" Thick x 24" Wide Crushed Stone) .e I_s Engineering, P.C. Roanoke, Virginia 24019 RETAINING WALL B 0 MICt1AEL R. C1 yr Phone: 540 366-2379 TOC Top of Cap Unit ® ( ) TOW Top of Wall (Excluding Cap Unit) MJ• Q21245 Sta. 0 to Sta. 54 .0 l BOW Bottom of Wall (Including Embedment) 'S+A 2.5 ZZ Scale: H' 1"= 10 ft. — — 60 StratoGrid SGV60 Viewed From Front Face of Wall '41 �a;. V: 1"= 10 ft. Project No. RW-2740 S''ONAL G Date: 01/25/22 GL Geogrid Length (ft) 0 4" Drain Pipe to Daylight [Design Soil Bearing Pressure = 1,500 psf] Revision: I --- I Sheet 7 Of 12 WALL C ., r • 00 Eff..� NMI 20 528 o 526 j 524 N 522 W 520 BOW r 530.00 518 516 —BOW = 530.67 514 512 510 0 10 I I I� 6L=4.5 FT 524 BW'-- Sta. 40 _ r Sta. 60 YD-3E I LOT ENLARGED SITE PLAN St 42" Tall Pedestrian Guard - i�.r�nrrr��rrr irrrn�i�rrrr� •rlr��rrrr i BOW = 528.00 I I I I 1 1 1 1 BOW = 526.00 20 24 30 42 I I I I ------- GL = 6 FT WALL C w/ 42" Tall Pedestrian Guar Where 5pecified LEGEND ® Cap Unit (4" Height) Anchor Diamond Pro Units (8" Height x 18" Width) Leveling Pad (Min. 6" Thick x 24" Wide Crushed Stone) TOC Top of Cap Unit TOW Top of Wall (Excluding Cap Unit) BOW Bottom of Wall (Including Embedment) — 60 ' StrotoGrid SGV60 0 4" Drain Pipe to / 53QTW 524BG ; 522 BW / / TOC = 532.33 TOW = 532.00 GL=8FT 6L=8FT GL=8FT 6L=8FT 6" Thick Stone — Proposed Grade of Bottom of Wall Leveling Pad Drain Pipe to Daylight - 40 FT O.C. (Typical) BOW = 524.00 J S u 1 } I � I I BOW = 522.67 50 60 70 80 90 100 110 120 I Station (ft) I 6L=8FT 1 SLOPE5 51 EEPEK I HAN 3:15)HAL.L or_rLt%N 1 C V vv I WITH ANNUAL RYEGRASS BY ERNST CONSERVA 6o LBS. PER ACRE, OR 1 LB PER i,000 SF, UNLESS 5 VARIABLE WIDTH WAL 1 _ MAINTENANCE EASEMENT DB._PG._; cu . 528 TW �1 i 526.TW 522BG 520BG 524 TW 522 TW',' 520 TW 520 BW 518 BW 518BG 516BG 514BG 516 BW 514 BW 512 BW r7­53o.I _ 1 Stu. 120 — "Sm.1ao ysray160 1 522 Sto. 180 zoo ta. 220 Sta. 240 - — Sta. 260 — Use Granular or Low Plasticity Soil in Reinforced Fill Zone RETAINING WALL C Sta. 0 to Sta. 120 Viewed From Front Face of Wall [Design Soil Bearing Pressure = 1,500 Scale: I" = 20 FT 010 20 �,��aLTN OF Albemarle County, Virginia CIRCEO GEOTECH O Cl� Circeo 5956 Buckland Mill Road .e� L f GEngin Engineering, Roanoke, Virginia 24019 Engineering, P.C. 9 MIC4iAEl R. CI y, Phone: (540) 366-2379 N-3. 021245 rC �` 2Sf Scale: H` 1"= 10 fr. SSONAI ENG\ V. 1"= 10 ft22 Project No. RW-2740 Date: Revision: I --- Sheet 8 of 12 WALL C 540 538 536 534 532 530 t 528 o 526 524 IL t 522 {U 520 518 516 514 512 510 120 I 130 140 150 160 170 I80 190 200 210 220 230 240 I Station (ft) I GL = 8 FT _I 1 1 TW 522TWr�d 3BG 516BG i0 dj S20 TW BW 514 BW 514BG 1� 1 1 52'L— Sta. 220 Sta. 240 Sta. 260- —/..., ;;;,I.L _ _ LEGEND ® Cap Unit (4" Height) Anchor Diamond Pro Units (8" Height x 18" Width) Leveling Pad (Min. 6" Thick x 24" Wide Crushed Stone) TOC Top of Cap Unit TOW Top of Wall (Excluding Cap Unit) BOW Bottom of Wall (Including Embedment) — 60 ' StrotoGrid SGV60 0 4" Drain Pipe to 506 TW 518 TW 516 TW 514 TW 512 TW - 504BG 5 04BG 5101 02 BW 51:2BG 510BG 508BG t% 506BG 505B&G 502 BW 510 BW 508 BW 506BW 504 W502.62 �W Sta. 280 ,.1t--� Sta. 300 — Sta. 320 � Sta. 340 506or ' YD-3B J WALL C w/ 42" Tall Pedestrian Guard Where Specified Use Granular or Low Plasticity Soil in Reinforced Fill Zone RETAINING WALL C Sta. 120 to Sta. 240 Viewed From Front Face of Wall [Design Soil Bearing Pressure = 1,500 360 I �3 II - Sta. 420 — Sto. 400 ' Sto. 380 — 1Y - ENLARGED SITE PLAN 504 TW SO4BG 502 BW 4 9 PROPOSE[ DRAIN IN 0 7 N .° V) N V m J s u 0 FA Scale: 1" = 20 FT o10 20 Albemarle County, Virginia CIRCEO GEOTECH Circeo 5956 Buckland Mill Road Geotechnical ff,MW Engineering, P.C. Roanoke, Virginia 24019 MICHAEL R. CI ® Phone: (540) 366-2379 No. 021245 11251za Scale: H' 1"= 10 ft. FS G� V: 1"= 10 ft. Project No. RW-2740 '*OVAL Date: 01/25/22 Revision: --- Sheet 9 of 12 WALL C 528 526 524 522 0 520 N , , 518 516 0 514 N V c [5- 512 510 508 } 506 504 502 500 498 240 I I 522 520 518 516 N 514 d N + tb 510 0 508 U 506 504 LU J 502 L u 500 498 496 494 492 TOC = 520.33 TOW = 520.00 GL=8FT GL=8FT GL=8FT GL=8FT BOW = 513.33 BOW = 512.00 BOW = 510.00 - Proposed Grade at Bottom of Wall T Drain Pipe to Daylight - 40 FT O.C. (Typical) 250 260 270 280 TOC = 518.33 TOW = 518.00 GL=8FT 6L=8FT 6L=8FT BOW = 508.00 290 TOC = 516.33 TOW = 516.00 :• 0. of �llzx rr . Station (ft) GL=8FT — IMMMM MIERM33 r�0 10111Wl. 11 1 1 1 �11 E� ��m MMIMM1111 =� �� wM �MMMMME r�r�r�r�=ME MM I1WMAIME MMEME r�r�r�r�lrwi.r�r�r�r�MMrsam —==�����i EM �roacai — =- 1•u mommimmmommoom rrr�rYrrirrr��rlrrirr�r��.dmQi. —_ _ _ _ _ _ _ _ _. r�r�r�r�r�rll ���� r�r�r�liir�r�r�r�r�r�r�r�l>• I� la �_�_�_�_�_�_.._ a==W4 .&�. • Mr..oQei.&�A. • I RM t trrli rrR�l.fa Irr�rrrr 6" Thick Stone BOW 503.33 Leveling Pad Proposed Grade at Bottom of Wall J BOW = 502.67 (Low Point) Drain Pipe to Daylight - 40 FT O.C. (Typical) 360 370 I I lid &L=6FT. LEGEND ® Cap Unit (4" Height) Anchor Diamond Pro Units (8" Height x 18" Width) Leveling Pad (Min. 6" Thick x 24" Wide Crushed Stone) TOC Top of Cap Unit TOW Top of Wall (Excluding Cap Unit) BOW Bottom of Wall (Including Embedment) — 60 ' StratoGrid SGV60 0 4" Drain Pipe to Tall Pedestrian Guard TOC = 514.33 TOW = 514.00 6" Thick Stone Levelina Pad 320 330 TOC = 504.33 [TOW = 504.00 V ON O N 3 � c } W —BOW = 502.67 (Low Point) 380 390 393 400 410 420 429 I Station (ft) I !� GL=4.5FT 1 Use Granular or Law Plasticity Soil in Reinforced Fill Zane RETAINING WALL C Sta. 240 to Sta. 429 Viewed From Front Face of Wall ght [Design Soil Bearing Pressure = 1,500 psf] MICHAEL R. C1W M.). 021245 Ml.11l �..ME� • Mi.MMMMIMMMMI MIMMMMI - rrrrrr.rrr rrrrrir -------- — - r � Albemarle County. Viroinia Circeo 5956 Buckland Mill Road s Geotecherir Roanoke, Virginia 24019 _ Engineering, P.C. 9 ® Phone:(540) 366-2379 Scale: V: 1"= 10 ft. Project No. RW-2740 Date: 01/25/22 Revision: --- I Sheet 10 of 12 WALL E i ■ �--� ---■—I----I -•------- -------■------------------------ -----■■ �— ---- — ----' ----• ----- ---- ---- ----- ---- ----- ■ice 1 ■ ■■�i�•dr■iir■■■Iri■/I■■. ■ ■ ��r■ri/■---■LN���-- ---■----��'/�YV OY�rI pita�»GI • I �»■-�� • I..ILi�ILri■i±�4i■■ ■ I • R/�Q4 BOW 48 -BOW 488.0 0 LEGEND ® Cap Unit (4" Height) 0 Anchor Diamond Pro Units (8" Height x 18" Width) Leveling Pad (Min. 6" Thick x 24" Wide Crushed Stone) TOC Top of Cap Unit TOW Top of Wall (Excluding Cap Unit) BOW Bottom of Wall (including Embedment) — 60 • — ' SrratoGrid SGU60 0 4" Drain Pipe to DC = 490.33 DW = 490.00 W — -It o un 3 0 V) W BOW = 488.00 OW = 486.00 Use Granular or Low Plasticity Soil in Reinforced Fill Zone �I ° LOT I LOT 2 4 33 VARIABLE WIDTH WALL & MAINTENANCE EASEMENT TPG. DB. i i f 490 "ter 2 — ACI W = _ E— Sia. o ' Sta. 40 Sta54 -- X of WALL E - 490 TW STA. 0+54 �... 490 TW - 486 BT .� 484 BW- 490BG -A: +0 484 BW 484 B WALL E - LCIUW . w/ 42" Tall Pedestrian Guard 49013G Where 5pecif led �84 B ENLARGED SITE PLAN RETAINING WALL E Sta. 0 to Sta. 54 Viewed From Front Face of Wall [Design Soil Bearing Pressure = 1,500 Albemarle PROPOSED _ ___RETAINII DIAMOI COLOR:B Scale: 1" = 20 FT 0 10 20 Circeo Geotechnical 5956 Buckland Mill Road sgineering, P.C.PCRoanoke, Virginia 24019 NAEL R. C! y, Phone: (540) 366-2379 Q21245 IIISIZ7 4� H: V= loft. Scale: Get' V: 1"= 10 ft. Project No. RW-2740 s'iONAL Date: 01/25/22 Revision: --- Sheet 12 of 12