HomeMy WebLinkAboutSDP202100096 Review Comments Initial Site Plan 2022-03-17 (2)c or nt 401 McIntire Road, North Wing
Charlottesville,VA22902-4579
County of Albemarle Telephone: 434-296-5832
COMMUNITY DEVELOPMENT DEPARTMENT WWW.ALBEMARLE.ORG
Memorandum
To: Ben Holt
From: John Anderson
Date: 3/11/2022
Subject: Pleasant Green Phase III — Preliminary Subdivision & Initial Site Plan - DIGITAL
(SDP202100096)
The Pleasant Green Phase III ISP (preliminary plat) has been reviewed by Engineering. The following
comments will need to be addressed with the final site plan (or plans submitted prior to FSP):
1. Revise Phase III ISP consistent with Road Plan, Pleasant Green Phase II (SUB202000226), which is
under review, and nearing approval. Albemarle cannot approve plans in conflict with one another.
Developer preference appears to be to receive Phase II road plan approval required for Phase II
site or final subdivision approval, which is fine. Phase III ISP-preliminary plat review, however,
cannot proceed to approval until Phase II and Phase III road-site-plat-WPO plans are consistent
with one another. For example:
a. Street layout /alignments differ.
b. Proposed public RW varies (Phase II RP, Lexi RW =54'; ISP, Lexi RW =49').
Phase II Road, sheet 4 (plan d. 12/27/21)
�_ � � POSED CENG aN�
O
PHASE III po .r°gFNN-
oe�' cT
lrt
cy
B
PHASE II
Engineering Review Comments
Page 2 of 3
Phase III ISP, sheet 1 /Cover (plan d. 2/13/22)
ftTi
vxsxn��
' ij',x�
�.-
— + PXISEI
.......+.^.. J K
�_
2. Phase III FSP aooroval requires:
a. An approved Phase III road plan (with roads built or bonded).
b. Note: WPO202000053, Pleasant Green Phase II, Approved 10/1/21, appears unaffected
by any inconsistencies in Phase II -Phase III subdivision layout; in addition, WPO plan
sheet 1(plan title sheet) SWM plan note reads: 'The facilities designed with the Phase II
portion of the Pleasant Green development were sized for the proposed Phase III
development and impervious area. Additional nutrient credits will be purchased for the
Phase III portion of the project to meet water quality requirements, but the Phase II
facilities provide the required water quantity for this portion of the development'
c. A Phase III WPO plan (SWIM ref. to WPO202000053, ESC measures required for Phase
III) must be approved prior to Phase III FSP approval (or final Phase III subdivision).
3. Sheets 3, 4
a. Please ref. deed bk.-pg. for sight distance easement (rt.) at Int. McComb Street and
Litchford Road, or establish sight distance right, at this intersection, if not recorded. Sight
distance easement may be recorded with Phase III final subdivision plat.
b. Show private entrances extending across sidewalks to FC for all lots, similar to linework
shown for lots 58-64 fronting Litchford Road (Phase II).
c. Display private entrance curb radii, graphically (to help minimize conflicts with water
meters, for example), similar to linework shown for lots 58-64.
d. Provide lines to demarcate individual parallel parking spaces for on -street parking.
4. Sheet 5
a. Provide deed bk.-pg. reference for existing public /private drainage easements (recorded
with phase I or II final subdivision plats).
b. Establish public drainage easements on lots with storm pipes serving public streets that
cross exterior lot lines, from public RW to lot interior (Lots 211-215, for example).
5. Provide LD-204, stormwater inlet computations, LD-229, stormwater drain design computations.
6. Provide storm drain profiles, for Phase III structures and pipes.
7. Sheet 6
a. Provide storm capture behind attached units to ensure stormwater surface runoff does
not cross more than three lot lines. For example: please provide capture /conveyance in
Engineering Review Comments
Page 3 of 3
areas behind attached units (for example: lots 162-167, 185-194, 229-234, similar to that
provided for Phase II lots 131-136.
b. Revise proposed grade contours to ensure grate /yard inlet capture for lots, as needed.
c. Provide private drainage easements for yard inlet systems, item a., above.
8. Sheet 7: DP, D, pavement design values are accurate, and sufficient for projected ADT.
9. Note: Pleasant Green Phase III is partially covered by WPO20200053, Approved 10/1/21, but a
separate WPO is required to meet all ordinance /state stormwater /ESC requirements. Also, item
2_b., above.
SDP202100096_Pleasant Green Phlll_prelim plat -initial site_031122.docx
(Z)
COMMONWEALTH of VIRGINIA
DEPARTMENT OF TRANSPORTATION
Stephen C. Brich, P.E. 1401 East Broad Street
Commissioner Richmond, Virginia 23219
March 15, 2022
County of Albemarle
Department of Community Development
401 McIntire Road
Charlottesville, VA 22902
Attn: Ben Holt
(804) 786-2701
Fax: (804) 786,2940
Re: SUB-2021-00096 — Pleasant Green Subdivision, Phase 3 — Preliminary Site Plan and Plat
Review # 2
Dear Mr. Holt:
The Department of Transportation, Charlottesville Residency Transportation and Land Use
Section has reviewed the Pleasant Green Subdivision, Phase 3 — Preliminary Site Plan and
Preliminary Plat, dated February 13, 2022 as submitted by Collins Engineering, and find the
following:
1. Existing Phase 2 is not shown correctly.
2. Phase 3 appears to have overlapped phase 2 for the block between Dunnagan Drive and
Lexi Lane. Please clarify.
3. CG-12's appear to be missing from Dunnagan Drive, sheet 4.
4. Lexi Lane does not match phase 2 Lexi Lane per Albemarle County plan #SUB-2020-
00226.
5. Please include Dunnagan Drive in the Typical street sections.
6. Planting plan should be included.
7. Please include a note stating "Landscaping plants and trees adjacent to the sight distance
triangle will need to be maintained in area between 2 and 7 feet above ground as a clear
zone to preserve sight lines and accommodate pedestrians. The HOA will be responsible
for the maintenance of sight lines."
8. Provide drainage calculations.
9. Please include a note stating that VDOT will only maintain within drainage easements to
the extent necessary to protect the roadway from flooding or damage.
10. Show "No Parking" signage on all roads except in areas with designated parking.
Begin/end signs should be shown to delineate areas.
11. Please show the mail boxes & cluster box units per RDM Appendix B(1)-56
VirginiaDOT.org
WE KEEP VIRGINIA MOVING
12. Approved road plans meeting SSAR, and in compliance with the VDOT Road Design
Manual are required prior to plat approval.
13. Due to the required changes additional comments or conditions will be forthcoming.
14. Please provide a comment response letter with each submission after the initial.
15. Note that the final plan must show conformance with the VDOT Road Design Manual
Appendices B(1) and F, as well as any other applicable standards, regulations or other
requirements.
A VDOT Land Use Permit will be required prior to any work within the right-of-way. The
owner/developer must contact the VDOT Charlottesville Residency Land Use Section at (434)
422-9399 for information pertaining to this process.
If you have further questions, please contact Max Greene at 434-422-9894.
Sincerely,
John C. Wilson, P.E.
Assistant Resident Engineer
Area Land Use
VDOT - Charlottesville Residency
SDP2021-96 Pleasant Green — Phase 3 Initial Site Plan — 2"" submission
Comments: Albemarle Co Fire & Rescue — Howard Lagomarsino
hlaeomarsino@albemarle.org
03-10-2022
1) acknowledged the note about fire flow data will be included on the final site plan. Ensure this includes
hydrant flow and needed flow for buildings.
2) Ensure final site plan includes the following note:
During construction, the following fire prevention steps are required, so please note them on the plan:
a) Smoking shall be prohibited in areas where smoking makes conditions such as to make smoking a
hazard and these areas shall be designated with no smoking signs per Virginia Statewide Fire Prevention
Code.
b) Areas where smoking can occur, shall have appropriate receptacles for discarded smoking
materials per Virginia Statewide Fire Prevention Code.
c) Per the Virginia Statewide Fire Prevention Code, vehicular access for firefighting shall be provided
at all construction and demolition sites, provide access to within 100 ft. of temporary or permanent fire
department connections, and have no overhead wiring or other overhead obstructions lower than 13 ft.
6 inches; this access may be via permanent or temporary road, but shall be capable of supporting fire
apparatus in all weather conditions.
d) Contractor shall ensure the street numbers are always plainly visible from the frontage street
during construction per the Virginia Statewide Fire Code
e) An approved water supply for firefighting operations shall be in place and available as soon as
combustible materials arrive on site.
f) Waste and combustible debris shall be removed from the building at the end of each day and
disposed of in accordance with the Virginia Statewide Fire Code
g) Fire extinguishers shall be provided, with not less than one approved fire extinguisher at each
stairwell, on all floor levels where combustible materials have accumulated, in every storage and
construction shed and in areas of special; hazards, such as where flammable and combustible liquids are
stored or used, in accordance with the Virginia Statewide Fire Code
h) Operations involving the use of cutting and welding shall comply with the Virginia Statewide Fire
Prevention Code and shall require a permit from the Albemarle County Fire Marshal's Office