Loading...
HomeMy WebLinkAboutWPO202200011 Plan - VSMP 2022-03-21Sheet List Table RIO POINT WPO - 2022 - COUNTY OF ALBEMARLE, VIRGINIA SITE DATA: TAX MAP PARCEL AND OWNER INFO: PARCEL 06100-00-00-167CO D.B. 1681, PG. 174 RIO POINT LLC 123 EAST MAIN ST 5TH FLOOR CHARLOTTESVILLE, VA 22902 PARCEL 06100-00-00-16700 D.B. 1688, PG. 564 RIO POINT LLC 123 EAST MAIN ST 5TH FLOOR CHARLOTTESVILLE, VA 22902 EXISTING AREA: PARCEL 06100-00-00-167CO = 25.73 AC. PARCEL 06100-00-00-16700 = 1.58 AC. EXISTING ZONING: R4 - RESIDENTIAL AREA PROPOSED ZONING: PLANNED RESIDENTIAL DEVELOPMENT (PRD). PROPERTY SHALL STILL COMPLY WITH EXISTING ZONING OVERLAY DISTRICTS OVERLAY DISTRICT: PRESERVED SLOPES SHOWN PER ALBEMARLE COUNTY GIS, AIRPORT IMPACT AREA (AIA), FLOODPLAIN HAZARD OVERLAY DISTRICT (FH), AREAS OF MANAGED AND PRESERVED SLOPES OVERLAY DISTRICT, AND ENTRANCE CORRIDOR OVERLAY DISTRICT (EC). THESE OVERLAY DISTRICTS ARE NOT BEING REVISED AS PART OF THE PROJECT. MAGISTERIAL DISTRICT: RIO CURRENT USE: SINGLE FAMILY DETACHED (SFD) HOUSE PROPOSED USE: RESIDENTIAL SOURCE OF SURVEY, BOUNDARY, AND TOPOGRAPHY: TIMMONS GROUP 1001 BOULDERS PARKWAY SUITE 300 RICHMOND, VA 23225 804-200-6500 PROJECT #: 46883 DATE: 12/11/2020 DATUM: HORIZONTAL: NAD83 VIRGINIA STATE GRID SOUTH ZONE VERTICAL: NAVD88 WETLAND IMPACTS: NONE UTILITIES: ACSA WATER AND SEWER WATERSHED: RIVANNA RIVER - MEADOW CREEK FLOODPLAIN: THERE IS A FLOODPLAIN LOCATED ON THIS SITE. FEMA MAP ID 51003CO280D DATED FEBRUARY 4, 2005. IN ADDITION, A DAM BREACH INUNDATION ZONE EXISTS ON THE PROPERTY FOR THE SOUTH RIVANNA DAM, WHICH IS A FEDERAL DAM LOCATED UPSTREAM OF THE PROPERTY. oz/o7/zoz2 .r OO PROJECT LOCATION �O �P 0 Q44/ O VICINITY MAP 1"-2000' DEVELOPER: RIO POINT LLC 123 EAST MAIN ST 5TH FLOOR CHARLOTTESVILLE, VA 22902 CONTACT: CHRISTOPHER HENRY CHENRY@STONYPOINTDG.COM ENGINEER OF RECORD: TIMMONS GROUP 608 PRESTON AVE. SUITE 200 CHARLOTTESVILLE, VA 22903 CONTACT: CRAIG KOTARSKI, P.E. TELEPHONE: (434) 327-1688 Sheet Number Sheet Title C0.0 COVER C0.1 REZONING PLAN C1.0 NOTES & DETAILS C1.1 NOTES & DETAILS C1.2 NOTES & DETAILS C1.3 NOTES & DETAILS C2.0 OVERALL EXISTING CONDITIONS PLAN C2.1 EXISTING CONDITIONS & DEMOLITIONS PLAN C2.2 EXISTING CONDITIONS & DEMOLITIONS PLAN C2.3 EXISTING CONDITIONS & DEMOLITIONS PLAN C2.4 EXISTING CONDITIONS & DEMOLITIONS PLAN C2.5 EXISTING CONDITIONS & DEMOLITIONS PLAN C2.6 EXISTING CONDITIONS & DEMOLITIONS PLAN C3.0 EROSION & SEDIMENT CONTROL NOTES & DETAILS C3.1 EROSION & SEDIMENT CONTROL DETAILS C3.2 EROSION & SEDIMENT CONTROL DETAILS C3.3 EROSION & SEDIMENT CONTROL - PHASE 1 C3.4 EROSION & SEDIMENT CONTROL - PHASE 1 C3.5 EROSION & SEDIMENT CONTROL - PHASE 1 C3.6 EROSION & SEDIMENT CONTROL - PHASE 1 C3.7 ERIOSION & SEDIMENT CONTROL - PHASE 1 C3.8 EROSION & SEDIMENT CONTROL - PHASE 1 C3.9 EROSION & SEDIMENT CONTROL - PHASE 1 C3.10 EROSION & SEDIMENT CONTROL -PHASE 1 C3.11 EROSION & SEDIMENT CONTROL - PHASE 2 C3.12 EROSION & SEDIMENT CONTROL - PHASE 2 C3.13 EROSION & SEDIMENT CONTROL - PHASE 2 C3.14 EROSION & SEDIMENT CONTROL - PHASE 2 C3.15 EROSION & SEDIMENT CONTROL - PHASE 2 C3.16 EROSION & SEDIMENT CONTROL - PHASE 2 C3.17 EROSION & SEDIMENT CONTROL - PHASE 2 C3.18 EROSION & SEDIMENT CONTROL - PHASE 2 C4.0 OVERALL LAYOUT PLAN C4.1 LAYOUT & UTILITIES PLAN C4.2 LAYOUT & UTILITIES PLAN C4.3 LAYOUT & UTILITIES PLAN C4.4 LAYOUT & UTILITIES PLAN C4.5 LAYOUT & UTILITIES PLAN C4.6 LAYOUT & UTILITIES PLAN C4.7 LAYOUT & UTILITIES PLAN C4.8 LAYOUT & UTILITIES PLAN C5.0 GRADING & DRAINAGE PLAN C5.1 GRADING & DRAINAGE PLAN C5.2 GRADING & DRAINAGE PLAN C5.3 GRADING & DRAINAGE PLAN C5.4 GRADING & DRAINAGE PLAN C5.5 GRADING & DRAINAGE PLAN C6.0 INLET DRAINAGE AREA MAP C6.1 INLET DRAINAGE AREA MAP C7.0 PRE DEVELOPED DRAINAGE AREA MAP C7.1 PRE DEVELOPED DRAINAGE AREA MAP C7.2 POST DEVELOPED DRAINAGE AREA MAP C7.3 POST DEVELOPED DRAINAGE AREA MAP C7.4 STORMWATER CALCULATIONS C7.5 STORMWATER CALCULATIONS C7.6 STORMWATER CALCULATIONS C7.7 STORMWATER CALCULATIONS C7.8 STORMWATER CALCULATIONS C7.9 STORMWATER CALCULATIONS C8.0 STORM PROFILES C8.1 STORM PROFILES C8.2 STORM PROFILES C8.3 STORM & SANITARY STRUCTURE & PIPE TABLES TOTAL: 63 SHEETS SIGNATURE PANEL DEPARTMENT OF COMMUNITY DEVELOPMENT PLANNING & ZONING ENGINEERING INSPECTIONS ARCHITECTURAL REVIEW BOARD DEPARTMENT OF FIRE AND RESCUE ALBEMARLE COUNTY SERVICE AUTHORITY VIRGINIA DEPARTMENT OF TRANSPORTATION HEALTH DEPARTMENT APPROVAL DATE V CRMG W. J. KOTARSKI Lic. No. 0402048507 .�,. 02-07-22, M E O b O U N � N C > E w ai E � w v 3 Q U. 3 p LL - w �-3 UoMo J -u d 7 O N C7W NV w � 30'x LL ti 0 N � M W J Z O a U U In W p z O U) w of DATE 02/07/2022 DRAWN BY . VAN NIEKER DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE zw J Omw Q OLL 0 ° c) �z O JOB NO. 46883 L SHEET NO. C0.0 SITE DATA (CONTINUED): TOTAL PROJECT AREA: AREA DEDICATED TO PUBLIC R/W. TOTAL DEVELOPABLE AREA EXISTING IMPERVIOUS AREA: PROPOSED IMPERVIOUS AREA: LIMITS OF DISTURBANCE: PROPOSED USE: PROPOSED UNITS: NET DENSITY: PROPOSED DENSITY: ALLOWABLE USES: BUILDING HEIGHT: OPEN SPACE REQUIRED: PARCEL 06100-00-00-167CO = 25.73 AC. PARCEL 06100-00-00-16700 = 1.58 AC. 27.31 AC. 0.82 AC. 27.31 AC - 0.82 AC = 26.49 AC. 0.212 ACRES 10.22 ACRES 18.44 ACRES RESIDENTIAL 130 - ONE BEDROOM APARTMENTS 124 - TWO BEDROOM APARTMENTS 30 - THREE BEDROOM APARTMENTS 15-TOWNHOUSE 299 TOTAL UNITS 28 ADDITIONAL UNITS PROPOSED WITH FUTURE BUILDING 327 UNITS OVERALL NET DENSITY CALCULATIONS (BASED ON THE ALBEMARLE COUNTY GIS COMPREHENSIVE PLAN MAPS) NEIGHBORHOOD SERVICE CENTER (3-20 UNIT/ACRE) x 5.33 ACRES = 15 UNITS (MIN.) & 106 UNITS (MAX) URBAN DENSITY RESIDENTIAL (6.01 -34 UNITS/ACRE) x 14.95 ACRES = 89 UNITS (MIN.) & 508 UNITS (MAX) PUBLIC & PRIVATE OPEN SPACE AREA (ZERO UNITS/ACRE) = 0 UNITS (MIN. & MAX) OVERALL ALLOWABLE NET DENSITY: 104 UNITS (MIN.) TO 614 UNITS (MAX.) 327 UNITS / 27.31 ACRES = 11.97 DU/AC THE ALLOWABLE USES FOR THIS DEVELOPMENT SHALL BE IN ACCORDANCE WITH SECTION 18-19.3 OF THE ALBEMARLE COUNTY ZONING ORDINANCE. THE MAXIMUM BUILDING HEIGHT FOR THIS DEVELOPMENT SHALL BE A 3 STORY BUILDING WITH A BUILDING HEIGHT NOT TO EXCEED 45 FEET. FOR EACH STORY THAT BEGINS ABOVE 40 FEET IN HEIGHT OR FOR EACH STORY ABOVE THE THIRD STORY, WHICHEVER IS LESS, THE MINIMUM STEPBACK SHALL BE 15 FEET. 25% X 26.49 AC = 6.62 AC OPEN SPACE PROVIDED: COMMON OPEN SPACE AREA = 7.49 AC (MIN.) OPEN SPACE TO BE DEDICATED TO PUBLIC USE = 1.1 AC ACTIVE RECREATION AREA = 1.0 AC (MIN.) CONSERVATION AREA DEDICATED TO PUBLIC USE = 5.89 AC GREENWAY TO BE DEDICATED TO PUBLIC USE = 0.12 AC TOTAL OPEN SPACE PROVIDED = 15.6 AC MIN (58.99%) OPEN SPACE CALCULATION: 26.49 AC - (CONSERV. AREA 5.89 AC) - (PARK 1.1 AC) - (GREENWAY 0.12 AC)) X 25% REQUIRED OPEN SPACE = 4.85 AC PROVIDED OPEN SPACE = 7.49 AC (COMMON) + 1.0 AC (ACTIVE) = 8.5 AC ACCESS: THE PROJECT CURRENTLY HAS (2) ACCESS POINTS FROM RIO ROAD THAT WILL SERVE AS ACCESS TO THE SITE. THE DEVELOPMENT IS PROPOSING AN INTERCONNECTION TO TMP 61-167A AS SHOWN ON THE APPLICATION PLAN. THERE IS ALSO A PEDESTRIAN AND BICYCLE CONNECTION FROM THE PROPERTY TO THE CITY OF CHARLOTTESVILLE PROPERTY ADJACENT TO THE DEVELOPMENT. FIRE & RESCUE: THE PROJECT SHALL CONFORM WITH ALBEMARLE COUNTY FIRE AND RESCUE REGULATIONS FOR FIRE PROTECTION AND ACCESS TO THE SITE. ALL DRIVE LANES WITHIN THE APARTMENT COMPLEX THAT ARE ADJACENT TO A BUILDING ENVELOPE SHALL BE 26, IN WIDTH FOR FIRE PROTECTION OF THE 3 STORY BUILDINGS. PARKING REQUIRED: PER SECTION 18.4.12 OF THE ALBEMARLE COUNTY ZONING ORDINANCE. 1.50 x 130 ONE BEDROOM APT = 195 SPACES 2.00 x 124 TWO BEDROOM APT = 266 SPACES 2.00 x 44 THREE BEDROOM APT = 88 SPACES 2.25 x 15 TOWNHOUSES = 34 SPACES 601 TOTAL SPACES REQUIRED" "A PARKING WAIVER IS BEING PURSUED FOR A REDUCTION IN REQUIRED PARKING SPACES PARKING PROVIDED: 2 x DRIVEWAY SPACES PER (15) TOWNHOUSE = 30 SPACES 1 x TUCK UNDER GARAGE SPACES PER (15) TOWNHOUSE = 15 SPACES 442 REGULAR PARKING SPACES 28 ADA VAN SPACES 17 GARAGE SPACES 532 TOTAL SPACES PROVIDED ADA PARKING REQUIRED: FOR 401 - 500 TOTAL SPACES, 7 ACCESSIBLE SPACES REQUIRED, 2 OF WHICH SHALL BE VAN ACCESSIBLE = 9 TOTAL ADA PARKING PROVIDED: 28 VAN ACCESSIBLE SPACES TRIP GENERATION: PER TRAFFIC REPORT BY RAMEY KEMP ASSOCIATES, DATED MAY 24, 2021, THE TRIP GENERATION POTENTIAL OF THE PROPOSED NEIGHBORHOOD IS AS FOLLOWS: ITE TRIP GENERATION - TYPICAL WEEKDAY - 10TH EDITION LAND USE (ITE LAND USE CODE SIZE AVERAGE DAILY TRAFFIC (VPH) AM PEAK HOUR (VPH) PM PEAK HOUR (VPH) ENTER EXIT ENTER EXIT ENTER EXIT MULTIFAMILY HOUSING (MID -RISE) 328 UNITS 893 893 31 87 85 54 (221) RECREATION SPACE REQUIREMENTS REQUIRED PROVIDED TOT LOTS: 1 TOT LOT FOR THE FIRST 30 UNITS, 1 TOT LOT ACTIVE RECREATION AREA: 1.0 AC FOR EACH ADDITIONAL 50 UNITS = 7 TOT LOTS CLUBHOUSE TOT LOT SIZE: 5,000 SF FITNESS AREA SWIMMING POOL BASKETBALL COURT: ONE-HALF COURT FOR BASKETBALL RECREATION FIELD FOR EACH 100 UNITS = 3 HALF COURTS TRAILHEAD PARK: 1.1 AC HALF BASKET BALL COURT: 2,100 SF GREENWAY TRAIL: 0.65 AC TOTAL AREA REQUIRED: 5,000SF'7+2,100SF'3=41,300SF TOTAL AREA PROVIDED: 1.0 AC+1.1 AC+0.65 AC=2.75 AC = 0.95 AC Oriunnal Proffers X Amendment PROFFER STATEMENT ZMA 2019-00008' Project Name: Rio Point ( formerlN.'Park"ay Place) 'Fax Map and Parcel Number(s). 06100-00-00-167C0 and 06100=00-00-16700 Owner(s) of Record. Rio Point,'L'LC', a Virginia limited liability compam Date: June 7, 2021 Approximately 27.31 acres to he rezoned from R-a Residential to PRD - Planned Residential Development Rio Point, LLC is the sole owner (the "Owner ) Of' Fax Map and Parcel Nwnbers 06100-00-00- 167C0 and 06100-00-00-16700 (the "'Property"). which is the subject of rezoning application /MA 2019-00008- a project kninyn as "Rio Point _. (the "Project')I'tic Rezonmrt Application Plan for Rio Point Development- prepared by the Nimmons Group. comprised of a cover sheet ( Sheet 0), the Site Layout Plan (Sheet I )- Notes (Sheet 2 )- Grading Plan (Sheet 3), and Frontage Improvements (Sheet 4), dated April 2. 2021-'last revised June 4. 2021 is referred to herein as the "Application Plan". Pursuant to Section 33-3 of the Albemarle County Zoning Ordinance: the Ovynci hereby voluntarih proffers the conditions listed below yyhich shall be applied to the Property if It is rezoned to the zoning district identified above These conditions are prollered as a part of the requested rezoning and the Owner acknowledges that the conditions are reasonable Road Imurovements (a) Upon ,Nmittenrequest by Albemarle County, Oyyner shall dedicateapprosinlately 0.82 acres of land ("Dedicated Area") tier the future John Warner Parkway and Rio Road Roundabout. road frontage impco,-enunts. and shared use pathways. as shoyvn on the Application Plan. The Dedicated Area shall be dedicated yyithin ninety (90) days of the request by Albemarle County The Oyyner shall bear the costs of preparing- the Subdivision plat necessan for the dedication, of the Dedicated Area to Albematic Counh . The Owner shall provide a general warranty of title in the deed conveying the Dedicated Area. (b) Upon written request of Albemarle County: but no [sooner] l later"] than five (S) ~ears of the approval of ZMA 2019-00008, the Oyyncr shall make a the cash contribution toward the future John Warner I)arkw�av and Rio Road Roundabout ;2NJ38N 3-I. I�I:b�-+xxnu-u3; I ;2843883-I, 12I s67-0fg0J-03 constructed in coordination \yith, and shall be approved hy, the appropriate County authority Lind shall incorporate a shelter, a rest bench, pedestrian access- Lind signage ail in accordance with nlininitun standards consistent mill similar existing public transit stops located within the County. The Transit Stop shall he installed and completed concurrently with the Rio Road Improvements. If am portion of the transit Stop is located on the Property, the Oyyner shall dedicate it to public use or grantan easement as necessary to alloy% fur the public access and usage of the Transit Stop. (b) Notwithstanding the provisions Of subparagraph (a). tbllo\yine approval of ZMA 2019-00008, Should the Count Pieter that a transit stop be constructed in the location of the current bus stop on City-oy\lied property (Tax Map 06100-00-00-16900) on the north side of Rio Road East, or (h) should the County elect to receive funds fior constructing the Transit Strip in lieu of the Owners construction of the Transit Stop, the Count shall notitc the Owner in writing of the election to receive a cash contribution in lieu of the Transit Stop- and the Oyyner shall contribute Twenty Thousand Dollars ($20.000.00) to the :Count_\'s Capital Improvement Program (CIP) as a cash contribution for construction of the'Fransit Stop in either location the Oyyner shall make the cash contribution yyithin sixty (60) days from yvnttenrequest ol'the C ountc [THE REMAINDER OF THIS PAGE IS INTENTIONALLY BI,ANh,]j )<t -1, 1215674 Kuu-03: ;284i883-I, Cli'67-(gOW-1-U3;3) improvements Within ninety (90) days of receipt of the County request. the Owner ,hall contribute to the County-s Capital Improvement Program (CIP) bind Seven Ifondled and Filly_ Thousand Dollars ($750,000.00) as a cash contribution toyvard such unprovenlents- (c) Owner shall design and construct certain road Improvementsalong Rio Road includingrum lanes_ as shown on Sheet 4 of the Application Plan (the `Proposed Road Improvements- I- The Proposed Road Improvements arc conceptual and ale sublect to change haled on County and VDOT recommendations 'I he O�yner shall suhsnnur,Illy Complete the construction of the road improvements alone Rio Road in accordance kith final road plans approved by County (the -'Rio Road Improyements 1 prior to issuance of the first certificate of occupancy fix the Project The Rio Road Improvements shall be deemed "substantialk, complete" by one or mom of the tollo%ving methods:, whichever occurs first (I) the Albemarle County Engineer or Its designee determines them to be complete_ (it) they are ,constructed and inspected and the VDOT construction bond is released. or (in) a VDOT official otheryyise confirms that they are substantially complete '_. Trailhead Park (a) The Owner ,hall COI1StrUCt amenities in the trailhcad park \citlun the ..Open Space. I I Acic�_-. as noted on sheet I of the Application Plan and as approved by the County Parks and Recreation Department (the "Frailhead Park-)_ The Owner ,hall subsemtialh complete the Trailhead Park amenities: (w consist of a minimum Of 12 parking spaces, benches. trail connections, landscaping: public art and a gazebo or rather small structure), prior to issuance of the first certificate of occupancy: (b) Upon veritten request b}' the County, the Owner shall dedicate to the County by special varranty deed of tee simple title or Brant of perpetual casement, whichcycr is preferred by the County. for no consideration. the approximately 1.1-acre Trailhcad Park, as shown on the Application Plan Upon dedication: maintenance of the Trailhead Park yyill he the responsibilit ofthe Counh (unless tileCounty comcys its interest in the T railhead Park to the City of Charlottesville- in which case the City shall maintain it). The Oyyrlcr shall provide and maintain the public access casement to the Trailhead Park as shown on the Application Plan. 'the Owner must make the necessary suhdly ision application fix dedication, within nineh (90) days of receipt of ,the Counh's request and shall complete the dedication within thirty (30 ) days of receipt of final subdivision approval. 3. Transit Stop. (a) 'I Ile Oyvncr shall construct a public transit stop (the"Transit Stop") on the Property along the frontage of Rio Road East. The Transit Stop shall' be designed and, 2843883-t_ 12t567-(XX104-03;2 ^843881-1 L'1�67-01KH14-ul Signature Page for Proffer Statement for Rio Point. ZMA 2019-00008 TMPs 06100-00-00-167CO and 06100-00-00.16700 OWNER: RIO POIN 1', 11,11 A \ iruinia limited liabilih conipauy 13y: Manager 28R933-I. L'Uv7-utxuu-u3 ;. 2843883-1- 121567-IM )04-03;4 ;V'L.?':1 �F CRAIG W I. KOTARSKI Y Lic. No. 0402048507 02-07-22,,,z�; t7 DATE 0210712022 DRAWN BY R. VAN NIEKER DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE > Z z_J J I--q< O w cD LL m Q Z O LL o Z O I-1 ? wWN U L 1_ L JOB NO. 46883 SHEET NO. C0.1 LEGEND ROADS SEWER TRAFFIC STOP BAR ® C - S EXISTING SANITARY SEWER m STORM PIPE & STRUCTURE NO. DROP INLET & STRUCTURE NO. S�SAN-0--QS PROPOSED SANITARY SEWER CURB O PROPOSED SANITARY SEWER LABEL 0 CURB & GUTTER WATER DRY CURB & GUTTER EXISTING WATER LINE PROPOSED PAVEMENT g• yy PROPOSED WATER LINE 71 PAVED DITCH 0 g• yy PROPOSED VALVE - JUTE MESH DITCH -{-Z! g• yy PROPOSED TAPPING SLEEVE CENTERLINE OF DITCH PROPOSED FIRE HYDRANT (COMPLETE) L s Y BENCH MARK GRADING . �. CLEARING LIMITS R-1 VDOT STANDARD STOP SIGN TC = TOP OF CURB BC = BACK OF CURB EXISTING CONTOUR EP = EDGE OF PAVEMENT TW = TOP OF WALL 200 - PROPOSED CONTOUR BW = BOTTOM OF WALL TS = TOP OF STAIRS +240.5 EXISTING SPOT ELEVATION BS = BOTTOM OF STAIRS `TC 240.5 PROPOSED SPOT ELEVATION N/A = NOT APPLICABLE TO THIS PROJECT 0 PARKING COUNT CRITICAL SLOPES El JUNE 27, 2019 ACSA GENERAL WATER & SEWER CONDITIONS 1. WORK SHALL BE SUBJECT TO INSPECTION BY ALBEMARLE COUNTY SERVICE AUTHORITY (ACSA) INSPECTORS. THE CONTRACTOR WILL BE RESPONSIBLE FOR NOTIFYING THE PROPER ACSA OFFICIALS AT THE START OF THE WORK. 2. THE ALBEMARLE COUNTY SERVICE AUTHORITY SHALL HAVE ACCESS TO USE THE AIRSPACE ABOVE THE LOCATIONS OF CONSTRUCTION FOR THE FLIGHT OF UNMANNED AERIAL VEHICLES FOR THE PURPOSE OF IMAGERY COLLECTION. 3. THE LOCATION OF EXISTING UTILITIES ACROSS THE LINE OF THE PROPOSED WORK ARE NOT NECESSARILY SHOWN ON THE PLANS AND WHERE SHOWN ARE ONLY APPROXIMATELY CORRECT. THE CONTRACTOR SHALL, ON HIS OWN INITIATIVE, LOCATE ALL UNDERGROUND LINES AND STRUCTURES, AS NECESSARY. 4. ALL MATERIALS AND CONSTRUCTION SHALL COMPLY WITH THE CURRENT EDITION OF THE GENERAL WATER AND SEWER CONSTRUCTION SPECIFICATIONS, AS ADOPTED BY THE ACSA. 5. DATUM FOR ALL ELEVATIONS SHOWN IN NATIONAL GEODETIC SURVEY. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING MISS UTILITY (1-800-552-7001). 7. ALL WATER AND SEWER PIPES SHALL HAVE A MINIMUM OF THREE AND A HALF (3.5) FEET OF COVER MEASURED FROM THE TOP OF PIPE, OVER THE CENTERLINE OF PIPE. THIS INCLUDES ALL FIRE HYDRANT LINES, SERVICE LATERALS AND WATER LINES, ETC. 8. ALL WATER AND SEWER APPURTENANCES ARE TO BE LOCATED OUTSIDE OF ROADSIDE DITCHES. 9. VALVES ON DEAD END LINES SHALL BE RODDED TO PROVIDE ADEQUATE RESTRAINT FOR THE VALVE DURING A FUTURE EXTENSION OF THE LINE. 10. TREES ARE NOT PERMITTED IN THE ACSA EASEMENT. 11. THE CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH THE NO -LEAD REGULATION REGARDING BRASS FITTINGS EFFECTIVE JANUARY 4, 2014 (SENATE BILL 3874 WHICH AMENDS THE SAFE DRINKING WATER ACT). 12. THE SEWER LATERAL BEYOND THE CONNECTION AT THE SEWER MAIN SHALL BE PRIVATE. THE SEWER LATERAL STUB -OUT SHALL UNDERGO THE ACSA LOW-PRESSURE AIR TEST TO SATISFY COUNTY TESTING REQUIREMENTS. VISUAL INSPECTION OF THE SEWER LATERAL STUB -OUT SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 13. THE SEWER LATERAL BEYOND THE CONNECTION AT A MANHOLE SHALL BE PRIVATE. VISUAL INSPECTION AND PRESSURE TESTING OF THE SEWER LATERAL SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 14. THE FIRE SPRINKLER MAIN DOWNSTREAM OF THE GATE VALVE IS PRIVATE. VISUAL INSPECTION AND TESTING OF THE FIRE SPRINKLER MAIN DOWNSTREAM OF THE GATE VALVE SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING' PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 15. ALL FLUSHING OF FIRE SPRINKLER MAINS SHALL NOT OCCUR UNTIL APPROVAL IS GIVEN BY THE ACSA. 16. ALL WATER, SEWER AND FIRE LINES REQUIRE NEW INSPECTION AND TESTING PROCEDURES. THE ACSA PERFORMS ANY TESTING AND INSPECTIONS OF THE PUBLIC SEWER AND WATER MAINS . THE ALBEMARLE COUNTY BUILDING INSPECTIONS DEPARTMENT ACBID DOES A VISUAL INSPECTION AND WITNESSES THE TESTING OF THE BUILDING DRAIN, WATER SERVICE PIPE AND THE SPRINKLER LEAD-IN CONNECTION. THE DEVELOPER/CONTRACTOR IS RESPONSIBLE TO RETAIN A SPECIAL INSPECTOR AS OUTLINED IN THE UPDATED ALBEMARLE COUNTY POLICY FOR SITE UTILITIES TO PERFORM THE VISUAL INSPECTION AND TESTING OF ALL UTILITIES NOT COVERED BY THE ACSA OR ACBID. THIS INCLUDES BUILDING SEWERS, WATER, AND FIRE LINE BRANCHES BETWEEN THE MAIN AND THE METERS)/BUILDING(S). THE SPECIAL INSPECTOR'S REPORT MUST BE SUBMITTED AND APPROVED BY THE ALBEMARLE COUNTY ENGINEERING DEPARTMENT PRIOR TO A CERTIFICATE OF OCCUPANCY BEING ISSUED. GENERAL CONSTRUCTION NOTES FOR EROSION AND SEDIMENT CONTROL 1. THE PLAN APPROVING AUTHORITY MUST BE NOTIFIED ONE WEEK PRIOR TO THE PRE -CONSTRUCTION CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE WEEK PRIOR TO THE FINAL INSPECTION. 2. ALL EROSION AND SEDIMENT CONTROL MEASURES WILL BE CONSTRUCTED AND MAINTAINED ACCORDING TO MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK AND VIRGINIA REGULATIONS VR 625-02-00 EROSION AND SEDIMENT CONTROL REGULATIONS. 3. ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO OR AS THE FIRST STEP IN CLEARING. 4. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. 5. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO, OFF -SITE BORROW OR WASTE AREAS), THE CONTRACTOR SHALL SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND APPROVAL BY THE PLAN APPROVING AUTHORITY. 6. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY THE PLAN APPROVING AUTHORITY. 7. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION IS ACHIEVED. 8. DURING DEWATERING OPERATIONS, WATER WILL BE PUMPED INTO AN APPROVED FILTERING DEVICE. 9. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH RUNOFF -PRODUCING EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. 10. ALL FILL MATERIAL TO BE TAKEN FROM AN APPROVED, DESIGNATED BORROW AREA. 11. ALL WASTE MATERIALS SHALL BE TAKEN TO AN APPROVED WASTE AREA. EARTH FILL SHALL BE INERT MATERIALS ONLY, FREE OF ROOTS, STUMPS, WOOD, RUBBISH, AND OTHER DEBRIS. 12. BORROW OR WASTE AREAS ARE TO BE RECLAIMED WITHIN 7 DAYS OF COMPLETION PER ZONING ORDINANCE SECTION 5.1.28. 13. ALL INERT MATERIALS SHALL BE TRANSPORTED IN COMPLIANCE WITH SECTION 13-301 OF THE CODE OF ALBEMARLE. 14. BORROW, FILL OR WASTE ACTIVITY INVOLVING INDUSTRIAL -TYPE POWER EQUIPMENT SHALL BE LIMITED TO THE HOURS OF 7:OOAM TO 9:OOPM. 15. BORROW, FILL OR WASTE ACTIVITY SHALL BE CONDUCTED IN A SAFE MANNER THAT MAINTAINS LATERAL SUPPORT, OR ORDER TO MINIMIZE ANY HAZARD TO PERSONS, PHYSICAL DAMAGE TO ADJACENT LAND AND STRUCTURES/IMPROVEMENTS, AND DAMAGE TO ANY PUBLIC STREET BECAUSE OF SLIDES, SINKING, OR COLLAPSE. 16. THE DEVELOPER SHALL RESERVE THE RIGHT TO INSTALL, MAINTAIN, REMOVE OR CONVERT TO PERMANENT STORMWATER MANAGEMENT FACILITIES WHERE APPLICABLE ALL EROSION CONTROL MEASURES REQUIRED BY THIS PLAN REGARDLESS OF THE SALE OF ANY LOT, UNIT, BUILDING OR OTHER PORTION OF THE PROPERTY. 17. TEMPORARY STABILIZATION SHALL BE TEMPORARY SEEDING AND MULCHING. SEEDING IS TO BE AT 75 LBS/ACRE, AND IN THE MONTHS OF SEPTEMBER TO FEBRUARY TO CONSIST A 50/50 MIX OF ANNUAL RYEGRASS AND CEREAL WINTER RYE, OR IN MARCH AND APRIL TO CONSIST OF ANNUAL RYE, OR MAY THROUGH AUGUST TO CONSIST OF GERMAN MILLET. STRAW MULCH IS TO BE APPLIED AT 80LBS/100SF. ALTERNATIVES ARE SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 18. PERMANENT STABILIZATION SHALL BE LIME AND FERTILIZER, PERMANENT SEEDING, AND MULCH. AGRICULTURAL GRADE LIMESTONE SHALL BE APPLIED AT 90LBS/1000SF, INCORPORATED INTO THE TOP 4-6 INCHES OF SOIL. FERTILIZER SHALL BE APPLIED AT 1000LBS/ACRE AND CONSIST OF A 10-20-10 NUTRIENT MIX. PERMANENT SEEDING SHALL BE APPLIED AT 180LBS/ACRE AND CONSIST OF 95% KENTUCKY 31 OR TALL FESCUE AND 0-5% PERENNIAL RYEGRASS OR KENTUCKY BLUEGRASS. STRAW MULCH IS TO BE APPLIED AT 80LBS/100SF. ALTERNATIVES ARE SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 19. MAINTENANCE: ALL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER EACH RAINFALL EVENT. ANY DAMAGE OR CLOGGING TO STRUCTURAL MEASURES SHALL BE REPAIRED IMMEDIATELY. SILT TRAPS SHALL BE CLEANED WHEN 50% OF THE WET STORAGE VOLUME IS FILLED WITH SEDIMENT. ALL SEEDED AREAS SHALL BE RESEEDED WHEN NECESSARY TO ACHIEVE A GOOD STAND OF GRASS. SILT FENCE AND DIVERSION DYKES WHICH COLLECT SEDIMENT TO HALF THEIR HEIGHT MUST BE CLEANED AND REPAIRED IMMEDIATELY. 20. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS OF FINAL SITE STABILIZATION, WHEN MEASURES ARE NO LONGER NEEDED, SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 21. THIS PLAN SHALL BE VOID IF THE OWNER DOES NOT OBTAIN A PERMIT WTIHIN 1 YEAR OF THE DATE OF APPROVAL. (WATER PROTECTION ORDINANCE SECTION 17-204G.) 22. PERMANENT VEGETATION SHALL BE INSTALLED ON ALL DENUDED AREAS WITHIN NINE (9) MONTHS AFTER THE DATE THE LAND DISTURBING ACTIVITY COMMENCED. (WATER PROTECTION ORDINANCE SECTION 17-207B) GENERAL NOTES 1. CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS FOR AS BUILT DOCUMENTATION, AS REQUIRED BY THE LOCALITY. THIS INCLUDES, BUT IS NOT LIMITED TO, TESTING, INSTALLATION DOCUMENTATION, SURVEY, ETC. ALL REQUIREMENTS SHALL BE DISCUSSED WITH THE LOCALITY PRIOR TO THE BEGINNING CONSTRUCTION. 2. ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT VIRGINIA DEPARTMENT OF TRANSPORTATION'S SPECIFICATIONS AND STANDARDS. 3. PRIOR TO ANY CONSTRUCTION, THE CONTRACTOR SHALL CONSULT THE ENGINEER AND VERIFY THE APPROVAL OF THE PLANS BY ALL FEDERAL, STATE AND LOCAL AGENCIES. 3. LAND USE PERMITS (LUP-A) MUST BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION PRIOR TO BEGINNING ANY CONSTRUCTION WITHIN THE EXISTING STATE MAINTAINED RIGHT OF WAY (INCLUDING ACCESS). 4. VDOT IS TO RECEIVE WRITTEN NOTIFICATION 48 HOURS PRIOR TO COMMENCING WITH INITIAL CONSTRUCTION ACTIVITIES. 5. THE CONTRACTOR SHALL VERIFY THE ELEVATIONS OF ALL POINTS OF CONNECTION OR PROPOSED WORK TO EXISTING CURBS, SANITARY LINES, WATERLINES, ETC, PRIOR TO CONSTRUCTION. 6. UPON DISCOVERY OF SOILS THAT ARE UNSUITABLE FOR FOUNDATIONS, SUBGRADES, OR OTHER ROADWAY CONSTRUCTION PURPOSES, THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE OWNER. THESE AREAS SHALL BE EXCAVATED BELOW PLAN GRADE AS DIRECTED BY THE OWNER'S REPRESENTATIVE, BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED IN ACCORDANCE WITH SPECIFICATIONS. 7. ALL STORM SEWER DESIGN AND CONSTRUCTION TO BE IN ACCORDANCE WITH VDOT STANDARDS. 8. ALL STORM SEWER PIPE SHALL BE REINFORCED TONGUE AND GROVE CONCRETE PIPE IN ACCORDANCE WITH ASTM-C-76. PIPE WITHIN THE RIGHT OF WAY SHALL BE MINIMUM CLASS III OR GREATER IN ACCORDANCE WITH CURRENT VDOT STANDARDS AND SPECIFICATIONS. 9. IF PRE -CAST UNITS ARE TO BE USED, VDOT SHALL BE NOTIFIED AND THE MANUFACTURER SHALL SUBMIT DRAWING DETAILS FOR REVIEW. CERTIFICATION AND VDOT STAMP WILL BE REQUIRED ON ALL UNITS. 10. ALL CONCRETE SHALL BE A3-AE (AIR ENTRAINED 3,000 PSI), UNLESS OTHERWISE NOTED. 11. ALL ENTRANCES ARE TO BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH CURRENT VDOT STANDARDS. 12. DESIGN CHANGES, SPECIFIED MATERIALS CHANGES AND/OR FIELD CHANGES FROM THE APPROVED PLANS NEED TO BE RESUBMITTED TO THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. A LETTER OF EXPLANATION SHALL ACCOMPANY THE REVISED PLANS AND/OR THE DRAINAGE CALCULATIONS, WHICH MUST BE SUBMITTED AND APPROVED BY THE ENGINEER. 13. CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES SHOWN ON PLANS IN AREAS OF CONSTRUCTION PRIOR TO STARTING WORK. CONTACT ENGINEER IMMEDIATELY IF LOCATION OR ELEVATION IS DIFFERENT FROM THAT SHOWN ON PLAN. IF THERE APPEARS TO BE A CONFLICT, AND/OR UPON DISCOVERY OF ANY UTILITY NOT SHOWN ON THIS PLAN, CALL MISS UTILITY OF CENTRAL VIRGINIA AT 1-800-552-7001. THE OWNER SHALL BE RESPONSIBLE FOR THE RELOCATION OF ANY UTILITY WITHIN EXISTING AND/OR PROPOSED RIGHT-OF-WAY REQUIRED BY THE DEVELOPMENT. 14. CASING SLEEVES SHALL BE PLACED AT ALL ROAD CROSSINGS FOR GAS, POWER, TELEPHONE AND CABLE TV SERVICE TRUNK LINES. (N/A) 15. THE INSTALLATION OF SEWER, WATER, AND GAS MAINS (INCLUDING SERVICE LATERALS AND SLEEVES) SHALL BE COMPLETED PRIOR TO THE PLACEMENT OF AGGREGATE BASE COURSE. 16. VDOT & ALBEMARLE COUNTY APPROVAL OF CONSTRUCTION PLANS DOES NOT PRECLUDE THE RIGHT TO REQUIRE ADDITIONAL FACILITIES AS DEEMED NECESSARY. 17. VDOT SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER'S REPRESENTATIVE FOR INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). 18. A PRIME COAT SEAL BETWEEN THE AGGREGATE BASE AND BITUMINOUS CONCRETE WILL BE REQUIRED AT THE RATE OF 0.30 GALLONS PER SQUARE YARD (REC-250 PRIME COAT) PER VDOT STANDARDS AND SPECIFICATIONS. 19. THE SCHEDULING OF AGGREGATE BASE INSTALLATION AND SUBSEQUENT PAVING ACTIVITIES SHALL ACCOMMODATE FORECAST WEATHER CONDITIONS PER SECTION 315 OF THE ROAD AND BRIDGE SPECIFICATIONS. 20. THE OWNER'S REPRESENTATIVE SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER FOR INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). 21. A GEOTECHNICAL ENGINEER IS TO ASCERTAIN CAUSE AND CERTIFY RECOMMENDED METHOD OF REPAIR FOR ALL PAVEMENT STRUCTURAL FAILURES PRIOR TO STATE ACCEPTANCE. (N/A) 22. ALL VEGETATION AND ORGANIC MATERIAL IS TO BE REMOVED FROM THE PROPOSED PAVEMENT LIMITS PRIOR TO CONDITIONING OF THE SUBGRADE. 23. CERTIFICATION AND SOURCE OF MATERIALS ARE TO BE SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR ALL MATERIALS AND BE IN ACCORDANCE WITH THE ROAD AND BRIDGE SPECIFICATIONS, AND ROAD AND BRIDGE STANDARDS. 24. APPROVAL OF A DETAILED CONSTRUCTION SEQUENCING/MAINTENANCE OF TRAFFIC NARRATIVE FOR THE WORK ZONE IS A PREREQUISITE FOR ISSUANCE OF A LAND USE PERMIT ALLOWING ACCESS TO AND CONSTRUCTION WITHIN VDOT MAINTAINED RIGHT OF WAY. (N/A) 25. GRADE LINES ON PROFILES DENOTE FINISHED GRADE OF CENTER LINE OF ROAD. (N/A) 26. ALL APPROACH GUTTERS TO SAG INLETS SHALL MAINTAIN A MINIMUM SLOPE OF 0.004 ft./ft. 27. WHERE A TYPE "B" NOSE IS SPECIFIED ON AN INLET IN CONJUNCTION WITH ROLL FACE CURB AND GUTTER OR CG-7, THERE SHALL BE A 20' TRANSITION ON EACH SIDE OF THE INLET. (N/A) 28. CONTRACTOR SHALL PROVIDE A SEQUENCE OF CONSTRUCTION/MAINTENANCE OF TRAFFIC PLAN IN ACCORDANCE WITH THE STANDARDS AND GUIDELINES CONTAINED IN THE 2011 EDITION OF THE VIRGINIA WORK AREA PROTECTION MANUAL FOR REVIEW BY THE ENGINEER, OWNER'S REPRESENTATIVE, AND VDOT PRIOR TO STARTING WORK THAT IMPACTS TRAFFIC ON STATE ROADS. 29. ALL NEW HANDICAP ACCESSIBLE REQUIREMENTS ON -SITE (PARKING SPACES, ACCESS AISLES, AND ACCESSIBLE ROUTES) AND WITHIN ALL NEW STRUCTURES SHALL COMPLY WITH THE 2015 UNIFORM STATEWIDE BUILDING CODE, 2015 VIRGINIA CONSTRUCTION CODE, AND ICC/ANSI Al17.1-03. 30. THE CLEAR ZONE IS TO BE FREE OF STORED MATERIALS AND PARKED EQUIPMENT. 31. HORIZONTAL AND VERTICAL SIGHT DISTANCES SHALL BE FREE OF PARKED VEHICLES. 32. ALL EXCAVATED AREAS WITHIN THE CLEAR ZONE THAT HAVE A DEPTH GREATER THAN 6" SHALL HAVE A 6:1 STONE WEDGE PLACED AT THE END OF THE DAY 33. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 34. RETAINING WALLS GREATER THAN 3 FEET IN HEIGHT REQUIRE A SEPARATE BUILDING PERMIT. WALLS EXCEEDING 4 FEET IN HEIGHT REQUIRE A STAMPED ENGINEERING DESIGN ALSO. WALLS REQUIRE INSPECTIONS AS OUTLINED IN THE USBC. 35. ACCESSIBLE PARKING SPACES ACCESS ISLES AND ACCESSIBLE ROUTE SHALL BE INSTALLED IN ACCORDANCE WITH ]CC ANSI A117.1-09 AND THE 2015 VIRGINIA CONSTRUCTION CODE. 36. ALL ROOF DRAINS SHALL DISCHARGE IN A MANNER NOT TO CAUSE A PUBLIC NUISANCE AND NOT OVER SIDEWALKS. 37. BUILDINGS OR STRUCTURES BUILT BEFORE JANUARY 1, 1985 MUST HAVE AN ASBESTOS SURVEY PERFORMED IN ORDER TO APPLY FOR A DEMOLITION PERMIT. ASBESTOS REMOVAL PERMITS ARE REQUIRED IF POSITIVE FOR SUCH FROM ALBEMARLE COUNTY AND VDOLI. CONTACT VDOU FOR THEIR ADDITIONAL REQUIREMENTS AND PERMITS FOR DEMOLITION PROJECTS AT 540-562-3580 X131. BLASTING NOTES 1. BLASTING SHALL NOT BE PERMITTED ON THIS PROJECT. ALBEMARLE COUNTY STORMWATER MANAGEMENT NOTES 1. ALL DAMS AND CONSTRUCTED FILL TO BE WITHIN 95% OF MAXIMUM DRY DENSITY AND 2% OF OPTIMUM MOISTURE CONTENT. ALL FILL MATERIAL TO BE APPROVED BY A GEOTECHNICAL ENGINEER. A GEOTECHNICAL ENGINEER IS TO BE PRESENT DURING CONSTRUCTION OF DAMS. 2. PIPE AND RISER JOINTS ARE TO BE WATERTIGHT WITHIN STORMWATER MANAGEMENT FACILITIES. 3. FOR TEMPORARY SEDIMENT TRAPS OR BASINS WHICH ARE TO BE CONVERTED TO PERMANENT STORMWATER MANAGEMENT FACILITIES; CONVERSION IS NOT TO TAKE PLACE UNTIL THE SITE IS STABILIZED, AND PERMISSION HAS BEEN OBTAINED FROM THE COUNTY EROSION CONTROL INSPECTOR. ALBEMARLE COUNTY ENGINEERING GENERAL CONSTRUCTION NOTES 1. PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT OF WAY, INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT). THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS OF THE PERMIT SHALL GOVERN. 2. ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT. 3. EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN AND MUST BE INSTALLED PRIOR TO ANY CLEARING, GRADING OR OTHER CONSTRUCTION. 4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED. 5. THE MAXIMUM ALLOWABLE SLOPE IS 2:1 (HORIZONTALMERTICAL). WHERE REASONABLY OBTAINABLE, LESSER SLOPES OF 3:1 OR BETTER ARE TO BE ACHIEVED. 6. PAVED, RIP -RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. 7. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES. 8. UNLESS OTHERWISE NOTED ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE PIPE - CLASS III. 9. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). Albemarle County Engineering Final Plan General Notes Pagel of 4 ALBEMARLE COUNTY FINAL PLAN GENERAL NOTES General Construction Notes 1. Prior to any construction within any existing public right-of-way, including connection to any existing road, a permit shall be obtained from the Virginia Department of Transportation (VDOT). This plan as drawn may not accurately reflect the requirements of the permit. Where any discrepancies occur the requirements of the permit shall govern. 2. All materials and construction methods shall conform to current specifications and standards of VDOT unless otherwise noted. 3. Erosion and siltation control measures shall be provided in accordance with the approved erosion control plan and shall be installed prior to any clearing, grading or other construction. 4. All slopes and disturbed areas are to be fertilized, seeded and mulched. 5. The maximum allowable slope is 2:1 (horizontal:vertical). Where reasonably obtainable, lesser slopes of 3:1 or better are to be achieved. 6. Paved, rip -rap or stabilization mat lined ditch may be required when in the opinion of the County Engineer, or designee, it is deemed necessary in order to stabilize a drainage channel. 7. All traffic control signs shall conform with the Virginia Manual for Uniform Traffic Control Devices. 8. Unless otherwise noted all concrete pipe shall be reinforced concrete pipe - Class III. 9. All excavation for underground pipe Installation must comply with OSHA Standards for the Construction Industry (29 CFR Part 1926). V CRAIG W. J. KOTARSKI Lic. No. 0402048507 :�,. 02-07-22, ^� E 0 N OV N C > E w vE ¢U `T 3 LL LL � W 0 ^y W W L M ¢ J U 00 W J -Lri .. WN N v 3: 0 Z Y �x �_< Un= vN 2 U > N ¢ . C � o a' N � M a� OJ J toF- am O cc t7 N Z 0 f nr a DATE 0210712022 DRAWN BY R. VAN NIEKER DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE (j J LLj a I- D2:w w m < Q 06 00U) LU I-/� 0. O Z JOB NO. 46883 SHEET NO. C1.0 L �4„ 2" R -V,p L,TH Off,%, d CONIC CURB AND GUTTER CLASS 3A, ° (Fc=3,000 PSI) CONCRETE CONCRETE BUMPER BLOCK ANCHOR WITH EBAR j/ 6" IMBEDDED 24" IN GROUND N G OUND VA. SIGN FOR THE DISABLED ON 0.80 GAUGE 0 \ a a 1":1' -� 2.0" ASPHALTIC CONCRETE SURFACE HANDICAP SIGN /LOCATION (VAN) HANDICAP SIGN ALUMINUM. COLORS: GREEN BORDER & LEGEND, BLUE SYMBOL FOR ACCESSIBILITY, V CRATGW, J. KOTARSKI Y Lic.No. 0402048507 02-0�-22 d a a 13" �, COURSE - SM-9.5A LOCATION (TYP.) WHITE BACKGROUND. 'fA0 \ ° a ° a a'. a ° 7" 3.0" INTERMEDIATE BASE COURSE - BM25.0 1// COMPACTED a ° a ° a RESERVED RESERVEDpvfw SIGN :SIGNAL SUBGRADE EOP FACE OF PARKNG PARKNG STD. U POST \ °° a a A 8" TYPE 21-B AGGREGATE SUBBASE COURSE CURB GALVANIZED 1 \ T CONTINUE 21B STONE MA PAPER D 2% MAX. 18 18 4" MIN.MR; \\/\\\/\\\\\\\/\\\\\/�\\\/�\\ 4 BASE FROM ADJACENT 4„ VDOT g L 7 PAVEMENT SECTION SPEC. PAINTED N UNDER CURB COMPACTED SUBGRADE STRIPE > E 6" 6" 2'-0" (TYPICAL) RKTY PBI Y DENOTES HEAVY DUTY ASPHALT PAVEMENT ON PLANS 8' S' s' s' $' I�- TYPICAL VAN $W-WRT'E 1IM-WHE TOWAWAVZOPE TOWAWAYZOIE 6' _ Lu I._ w v 3 VDOT STANDARD CG-6 CURB & GUTTER F ACCESSIBLE ACCESSIBLE HANDICAP SPACES REGULAR SPACE T VAN POST TO BE Q LL o 3 w O o ^� ¢ °1J No Scale 6' ABOVE ACCESSIBLE 6' ABOVE DRIVEN i5 ip w - n z O NYLOPLAST DRAIN BASIN WITH DOME GRATE FINISHED FINISHED a > o N H GRADE GRADE cn Lu a, (1.2)INTEGTUTEDOUCTILEAiION GMTETD MATCH BA6NG°' 3 o 11 a HEAVY DUTY ASPHALT PAVEMENT SECTION TYPICAL PARKING SPACE DETAILS SPACES SHALL BE IDENTIFIED BY ABOVE GRADE in a o No Scale No Scale SIGNS AS RESERVED FOR PHYSICALLY U) = C" z R=%< DISABLED PERSONS. PROVIDE ONE (1) R-7-8 = < SIGN AT EACH PARKING SPACE INDICATED ON I I I_I I I _I I I_I I I -_III ~ o N > MINIMUMPIPESURIAL DEPTH PER PIPE A ADAPTERANGUESVARIABE 1 CONTROL JOINT SPACED SITE PLAN. SIGN SHALL BE ALUMINUM (PAINTED m MANUFACTURER D°-xP AccaRONoroHTAu I3)VAUGSLE(CCORDIEIGTO RECOMMENDATION AVAILABLE(ACOORDINGTO NON -SLIP BROOM FINISH AT WIDTH OF WALK (MAXIMUM) Ip WHITE) WITH GREEN LETTERS AND a v MIN.MANUFACTURING PUNSGAIEOFF) UGSAMEASMHSUMPI ry'- • ^ a '• EXPANSION JOINT AT MAX a } INTERNATIONAL WHEELCHAIR SYMBOL. SIGN OJ J o w � � • • OF 30', WITH PREMOLDED SHALL BE PLACED ON STEEL POST 1-1/2" 0 EXPANSION FILLER PAINTED BLACK SET IN MIN. 2' OF CONCRETE. VARIABLE WIDTH' CONC. WALK `� 0 IBA vARIABLE SIAr TIFPiH ACCORDINGTOPIANS MAX. CROSS SLOPE 2% ZiV1- (4) VMIWSTYPIS OF MLETaOUILETMRPTF.RS (6• MIN-Ox B'-2a•, tP MIN. 30- vl IN ON r-]¢' BASED ON MANUFACTURING RED) AVAILABLE: 4'-3Y FORCORRUGAlEOHOPE (ADS N-121HNNOOR DUAL WALL, ADSMPNCIXt > 6'MIN ON 3P SINGLEWALLLN-12HP,PVCSEWERIEx: SWISS), C7 O u \ \ \ \ a a \ \ \ � /i\� < ` • <<` :,.� . "° °' PVC DVYY CORRUGATED&C(SSEDPV. ;, I»RRUGATE0aw66EO PVC �.. < ��/\\\//�// .. , ; ADA PARKING SIGNS SIGN AND POST DETAIL WATERTIGHTJOIM THE BACKS L MATERIAL SHALL BE CRUSHED = FOR OTHER / • ' A . NO Scale No Scale o 0 0 (CORRUGATED HOPE SHOWN) GRANULARMATFRINL MEETING THE REQUIREMENTS OF CLASS I, r-w C SII,MCUS611IMATERIPLABDEFINEDINASTM02321./ / // BEDDING a SACKFUL FOR SURFACE DRAINAGE INLETS SHA L BE PLACED aCOMPACTED UNIFORMLY INACCORDANCE wImASTMOQ21. /��• 4' 3,000 PSI AIR -ENTRAINED EXISTING PAVEMENT PROPOSED PAVEMENT > ,W, 113 H �/�/�/�/�//� CONCRETE /COMPACTED ////i�//�/�/�/�/�/�/�/�/�/� Q 0 I-r-BY GONE GRATES BMML BE MORIE IRON PFRASIMAA9 z -eniv OMEGRA763FIrONOTHEORANIMSH5NrMTHEuff SUBGRADE 4" TYPE 21B STONE COVER COMPACTED SUBGRADE 4" 21-B STONE a _ SAWCUT THROUGH a MATCH EX. CROSS NOTE: PROPOSED J V EX. SURFACE W SLOPE UNLESS OTHERWISE PAVEMENT MUST TIE z O � CONCRETE SIDEWALK JOINT DETAIL DATE OFAWCBCOYTCP.SEENMMNGNO.MI.11W1B. INuyrl Br EBc ruTEnM. 3-DRiNR.awrG eEcuMa NMUFAOIIIN®ACCQNINGTOSHW mis PRwr OSLwsERNAR TNAD" X COURSE w SPECIFIED ON PLANS > `N RIGS SUPORGGAMIG CETNLB.NSENSOAENFECNGW mD_I1OVER&'GUEi08XIWIHG nYLWWrSIONHADPRWRIEiNw RIOESNTCONFER. PSN On GR]4518 REsIRICTIoxe. sEEMWwXGxo.1W1-11aNE. oRPp5sE551GNOFTnISPxNTCCE9xorCC11FER. WTF WSta Pxxlno9s:3W IN WITH EXISTING w &REMOVE 02/07/2022 No Scale .-DRnlxwscONxECTlaxsus»wrnallxssssnuL coxfoRMro TiM FER,0RUCENSETHEUSEWTnEOESIGNOR +� t` .( B]xiue A41M Dxxlx FdiGdiRUG4TFDxDF£10➢$x.l}MYILtlRDW,L WILL TECHNIMINFGRMGTONSXDVMXDEN REw9FDIN wx NWJEirxo.MYE ���1 •-•'^N•PN•�w�^ x.izxP,aPVC SEwER1e.N]. REPRODUCIONOFTXISPRINTGRMTwFORM IR1 TITIF 5-AOP➢IERSGNBEMOWT®aANYPNGIEPTOW.. MOUMINE CMRFINEDFEREIN, GRNNUFPCrUREGFMtt SATE MH1A, DR.NNSA%U` x OD QRA1E MINIMUM ANGLE BEIWFEx O➢APIERBEEEOMMxc N]rWl-t1001z A 1CLEHEREFRGM,FORTHEDISCLGSURETOGTSERs pIN.'1[$PECINBTANArICM CfTYL ISFORBDMN,ENCEFI"PECIFICM7SN • ^ ,p DENOTES CONCRETE SIDEWALK PAVEMENT ON PLANS PAVEMENT PAVEMENT PROPOSED 2' MIN. SURFACE I O } TOP OF CURB 4„ 1 1 R=2" DRAWN BY *THE DEPTH OF CURB MAY BE REDUCED AS 5-r H'OLMEGMTE6INYENO WD MTING PERMISGIONFRGM""°FUNS° „„D„„' MMGS A SCALE 1. SHEET IGF1 IMDNn rDP.I1DSR RN D �I, NOTE: SIDEWALKS SHALL BE CONSTRUCTED IN ACCORDANCE WITH VDOT STANDARDS. THE COLOR OF ALL FLATWORK SHALL BE I I 2"- COURSE _ R. VAN NIEKER "UVA CANVAS" \\\ \\\ 6" MUCH AS 3" (15" EXISTING DESIGNED BY NYLOPLAST DRAIN BASIN WITH STANDARD GRATE \�j\�j\ _ ; . .' DEPTH) OR INCREASED AS MUCH PAVEMENT • ). DENKO CONCRETE SIDEWALK PAVEMENT SECTION �j\\j\\j • (,, 2, INTEGRATED DUCTILE IRION SURFACE "' AS 3" (21" DEPTH) IN ORDER THAT THE MILL EX. SURFACE COURSE • No Scale CHECKED BY FRPME 8 GMT, TO MATCH BARIN 0.0. \\\\ BOTTOM OF THE BASE COURSE BASE VDOT A-3 CONCRETE CURB WILL COINCIDE SAWCUT EX. EDGE OF PAVEMENT AGGR. COURSE • • C. KOTARSKI 6•MIx TxICNNEss GUIDBINE MINIMUM PIPE BURIA 2.0" BITUMINOUS CONCRETE SURFACE COURSE-SM-9.5A/��� \ \ CONTINUE 21B STONE BASE FROM ADJACENT e WITH THE TOP OF A COURSE OF THE PAVEMENT • • SCALE PAVEMENT REPLACEMENT JOINT DETAIL NO Scale DEPTH PER PIPE (J)VMIABLE INVERTHEIGHB MANUFACTURER AVAILABLE (ACCOROINGTO RECOMMENDATION PAVEMENT SECTION UNDER CURB SUBSTRUCTURE. PLAy6rTq�IOPP) (MIN. MANUFACTURING I57 HITTER (6,7) TRAFFICLOADS: CONCRETE SLAB OIMFNSIOxSnRE FOR REQ.SAMEAS MIN SUMP) ANGLES GUIDELINE PURPOSES ONLY. ACTUALCONGRETESLABMUSTBE 8" TYPE 21B AGGREGATE BASE COURSE OTHERWISE, THE DESIG�� VAAAC�MG o• TRAFFIC LOADING IHOTHERAP JABLE LOCH SOIL GORE CONDITIONS, PCws TRAFFIC LOADINOaOTHERAPRICABLFDESIGN FAC�ORS. UB BASEJ DETH I$ TO BE 18" A$ SEE DRAWING NO. T001-11Dtll FOR NON TRAFFIC INSTALLATION, -JO(,JOLJVI,JV(,JOLJ � � SHOWN. � COMPACTED SUBGRADE -,� �� � SIGNAGE NOTES: 13) VARIABLE SUMP DEPTH I ACCIORDINGTOPtANS >,y (6'MIN.ON B'-24•. LP MN.Ory E" 1. ALL SIGNING AND PAVEMENT MARKING SHALL BE IN ACCORDANCE WITH VDOT STANDARD CG-2 CURB (4) VARIWSTYPESOFINETSOURETADAPTERS �I w„ I' CMINONS-N' BASED ON MANUFACTURING RED) AVAIIABLE:4•-3YFORCORRUG9EONOPE +.1n 8'MIN ON 3P - - THE MOST CURRENT EDITION OF EACH OF THE FOLLOWING AND ANY (AFWAL ,N4 I2HRDUALWWSR(EXERM,ANGm N, SINGLE wuu, Mlz HP, P/CSEwBR1Dts0R35), - - - - - - - - - - DENOTES LIGHT DUTY ASPHALT PAVEMENT ON PLANS No Scale REVISION THERETO: am PYC°""ICORRUGATESCHD& RIBBED A. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. WATERTIGHI'MNT THESAMU_MATERFLBEALLBSCRUSHEDSTONEOROTHER B. THE VIRGINIA SUPPLEMENT TO THE MANUAL ON UNIFORM TRAFFIC (WRRIUUGEDmnTeHOPE SHOWN) GRANULnRMATERIUMFFrwcTNEREaIREMENrsoFcussl, EXISTING PAVEMENT PROPOSED PAVEMENT CONTROL DEVICES. 4.3P CLASS IL OR CLASUL FOR MATERIALAEIDRAIEDIN ASTIM INUETS 2321. SMALL PlacEoaGDMPAGTFDUNIFDRMLYINACCIXNMWCEWITHASRADZJ2,. FLAGS) COMPACTED ANORDNCEWITHASTM C. THE VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD AND BRIDGE LIGHT DUTY ASPHALT PAVEMENT SECTION a SPECIFICATIONS. 1-e•-srsrMvu+DGRATSssxNLSEDULTIIEIRGx PpLASIMASN SAWCUT THROUGH a MATCH EX. CROSS j EX. SURFACE w D. THE 2000 INTERNATIONAL FIRE CODE. No Scale SLOPE UNLESS OTHERWISE 2-95nANSEDUCTALEIRplF£RAS,MANwGR•OE,oWG3, ra IrUANDPADGMTFS FITNRECRYCNTODMN R49NSIMTHTHE UBEOFAW060DYTCASEEwMMNGNOMJII a a-oRnNRsswroBECI.mTGEIMwuFAcluR®AccamlrNlTanw B•"'S"N ERN•ouETORIIwwG RETMS.RISERSEEDRAG X COURSE W SPECIFIED ON PLANS W &REMOVE 2. SIGN LOCATIONS ARE APPROXIMATE AND ARE TO BE MODIFIED IN THE FIELD TO AVOID CONFLICT WITH UNDERGROUND UTILITIES OR OTHER EXPANSION JOINT WITH NGNOR REsmlarloxs. sEENMWxcxorml.no-GH rxlsPRxrolscGoszssGBIECTMArTFAIxnHIa wuwNN SOruTWM GUEORRGAM11 4-MINAGELONNECT WUBMINTTIC4INEBBSHNLCONFMM NnWLpST HASPROERIETARYRIGXr5. T1ERECNP! BUFgN,GR]DE15 PREMOLDED EXPANSION 1/4" SEALANT PAVEMENT PROPOSED CONSTRUCTIONS, AND TO COMPLY WITH STANDARDS REFERENCED IN 0 AE1M OszIx FCRCCRRUGREDxDTE II➢s NIMWILbR[LLLLWNL) ORPosSMICNGFTHIS FRNTGOESnm WAFER. SATE I-SEM l PHx ITN S. 2' MIN. TAT x.rzxP,BNC eEwERIT.x4C. TRANSFER. OR UCENRE THE USE OF DESIGN OR y\yl0 aSf Fµ InM93]xtlD s- AMPTERSCPN BENDWTEDa MT ANG1Ea•ro30.•TODETETMNE TECHxICP1 wfGRIMnGN SHOM HMEIN REMMEDRT wx PR°IRn XDAIANE �'•'•^n.pIa.1..mm FILLER, "ZIP STRIP" OR NON -SLIP BROOM FINISH SURFACE NOTE 1 ABOVE. uNIMU.m.GG.BNADAPTER$sTEDRAMxGxGDll1-1IGMz RE➢RODUCIONOFTXISEUNTGRMTNFORMGTRI S-Ir-3Y SiµDNW gUT35MPILNFFrIF]GLMD R4RIG CGNTAINEDFEREIN� GRNWUFACTUREC£PHY pr,TG p],11-is T"`E DMNBASINWRXSTµDARDGRAIE EQUIV., SEAL WITH WWF 6x6 W2.9xW2.9 2" + COURSE - r piv°xom EWWnxE'�NFnFDRucinwlvRµA.wcT Is'FORDIDDEN P.']"NCRRBVsvECIFIC`'RIREPID"i"E� au¢NSRMI.11 L1ATIIXILETUL PERMISSICH FRCMXVLCNI$T ykgy, MYG 9JE A SLATE 1.W SHEEi IDF1 pWG NO. r[0Y1161M qEV M SILICONE SEALANT 211 3. ALL SIGNS AND PAVEMENT MARKINGS ARE TO BE FURNISHED AND a° . T 10" 3,000 PSI AIR ENTRAINED EXISTING PAVEMENT INSTALLED BY THE CONTRACTOR. ALL SIGNS TO BE FURNISHED AND INSTALLED WITH STANDARD U POST GALVANIZED BY THE CONTRACTOR. �/'� S' xs eARs a V. c-c TYP. es BARS a 9• :• .: •'. •..:..•..• ...:••. •..:.:...•.,. C-C TYP. �a .' PORTLAND �.. ' .'•" < V J _'_"_ t. • I I I I I I I I _I ;' I I A I 1 ` A e FT B CEMENT CONCRETE o 0 6" TYPE 21A STONE COVER / / / / / \ /y MILL EX.Lu SURFACE COURSE SAWCUT EX. BASE COURSE EDGE OF PAVEMENT AGGR. BASE SOLID WHITE LINE 24" STOP ('�P' � ~ J Q w 30" DwETER :'• 1 /\ A \� / /\ /\ COMPACTED SUBGRADE O LJ 06 TTTT I + (CBR 11.2) i a LL 06 TT NOTE: PROPOSED PAVEMENT MUST TIE 12' � L TTTTTT7 I :. TTT DENOTES CONCRETE SERVICE AREA PAVEMENT ON PLANS IN WITH EXISTING PAVEMENT R1-1 (VARIES) O (n ,' ..• Lu NOTE: STOP SIGNS TO BE 30" WITH STOP BAR DETAIL ~ HEAVY DUTY CONCRETE SECTION EMENT REPLACEMENT JOINT DETAIL FNoSca PLAN ST"TRUCTUR MOIRES PLAN OU No Scale le LASS HIGH INTENSITY SHEETING NO SCALE Z m CLASS A3 CONCRETE CLASS AT CONCRETE 10, SOLID WHITE LINE SECTION A -A �� SECTION B-B I ..,; ' I -III III -I I, � METAL INSPECTION FRAME W EXIST GRADE � SOLID LID (NEENAH R-1975 OR EOUI t/ALENT) 1. THE STANDARD SAFETY SLAB 01 IS TO BE USED ONLY WHEN SPECIFIED N THE PLANS ON THE ORANAGE SUMMARY SHEET ADXOR THE DRAINAGE DESCRIPTION. FOR MANHOLES. JUNCTION BOXES. AND DROP INLETS WITH HEIGHTS GREATER THAN 12 FEET THE SPACING OF ADJACENT SAFETY SLABS SHALL BE 8' TO IT WITH NO SAFETY SLAB LOOTED WITHINa FEET OF THE TOP OR BOTTOM OF THE STRUCTURE. SAFETY SLABS SHALL NOT BE LOCATED BELOW 1 III III -I I I -III III -- - - - - - - III III 'III- -_ III= - -III-III- - -III i'- - =H 3" CONCRETE COLLAR CRUSHED STONE BEDDING 6' ANY MET PIPE OF 30" DIAMETER OR GREATER. 2. THE COST OF THE SI IS INCLUDED N THE COST OF THE STRUCTURE. SEE CAST IN PLACE DRAWINGS FOR FURTHER DETAILS i- -I-III-III-III-I 1= I1- -III-III- -III-' - • -III-III 2" ASPHALT 6" DI CLEANOUT 3. ACCESS HERE AP ARE TO BE STAGGERED FROM ONE SIDE AC STRUCTURE RI THE OTHER WHERE APPLICABLE. STEPS ARE TO BE STAGGERED ACCORDINGLY. = N ° BARS ° e" C-C TYP. 6" COMPACTED VDOT OR PRECAST. CART-N-PLACESI CONCRETE TO BE 4. SAFETY SLAB MAY BE PRECAST S E PRECAST CONCRETE R A 9E A4 L4000 PSI).NC REINFORCING CLASS AT ABM PSI). STEEL TO BE N ACCORDANCE WITH AASHTO M31. .: :'^•>::.::.: .:': :' ';.:' •. #21 B STONE BASE 2' I I I 2' t-I I----i- e' LESS THAN 30" THE ACCESSGS MY BE °OPEHNNGG SHALLLL OR BE RE TCOTANNGULARE'(STRRUCTTURE MOTH BWIDTH Y COMPACTED PLUG AT END (TYP.) (TYP.) 3a' LONG). SUBGRADE - 95% S.P.D. OF LINE TYPICAL PRECAST UNIT xv=r TYPICAL CONCRETE SAFETY SLAB FOR DROP INLETS, SPECIFICATION 302 CLASS A - TYPE 2 LOW MAINTENANCE SHARED USE PATH STRIPING AND SIGNAGE DETAIL ROAD AND BPoDGE STANDARDSMANHOLES AND JUNCTION BOXES CLEANOUT DETAIL SHEET 1 aF 1 REVISION DATE OF TRANSPORTATION VIRGNIA DEPARTMENTNo No Scale - Scale No Scale JOB NO. 46883 SHEET NO. C1.1 0 d 0 3 a. D a0 o � O EZ 20 c � F a w c m OD w I In NO 0 NO o F N `ot. �Z Q n d it O Y GO NGO X C 0.0 N I 2 12 a � aD 06 a c 10DOa a 0 0.2 SD U c 2 D c � o c � TD n� w F E L -- VALVE BOX 4" DIAMETER BRANCH REMAINING BACKFILL SHALL AND VALVE NOT CONTAIN ROCK MATERIAL 36"MIN LARGER THAN 5" IN ANY DIMENSION .J. PLUG 24"MI INTIAL BACKFILL* VARIES 8"MIN (6" LIFTS) EMBEDMENT + THOROUGHLY COMPACTED SPRING LINE O BY HAND OR APPROVED OF PIPE MECHANICAL TAMPER ` HAUNCHING NO, 68 STONE WATER MAIN RESTRAINED JOINT FITTINGS BEDDING 6" max 4" min OUNDATION (SHALL BE 3 REQUIRED WHEN SOIL ON-LINE CONDITIONS ARE UNSTABLE (TYPE "B") ALL PIPE} vnrcl�a THREADED COUPLING NOTE BRASS NIPPLE AND PVC PVC SLEEVE o CAP 1. OPEN CUTS IN PAVED AREAS WITHIN EXISTING VDOT RIGHT-OF-WAY SHALL BE j LUBRICATE ALL THREADS BACKFILLED ENTIRELY WITH NO. 21A STONE. -L /.,METER 2. FOR DUCTILE IRON PIPE THE BOTTOM OF THE TRENCH SHALL BE SCRAPED THRUST BLOCK BOX (SEE FIG. W-7) AND COMPACTED, AND ALL STONES REMOVED OR A 4" BEDDING OF NO. 68 STONE SHALL BE PROVIDED' VALVE 3. WHERE ROCK IS ENCOUNTERED PIPE SHALL BE INSTALLED ON A MINIMUM 6" NO. 57 STONE BEDDING OF NO. 68 STONE ' M.J. FITTING 2" PIPE SLOPED TO DRAIN IF - GRADE ALLOWS VARIES VARIES 2" BRASS PIPE TYPICAL SEWER PIPE WATER MAIN AND VALVE 2" THREADED TAP INSTALLATION IN TRENCH ARE SAME SIZE PLUG DEAD END NTS FIG, S-3 (TYPE IIA") TYPICAL BLOW -OFF ASSEMBLY NTS FIG. W-8 F� 01-3A, 38,W EXPANSION KEYED CONST. BARB JOINT BM G BAR C 2•, - z ^ BARS F S+ I � > I -_ - - ...III _- ��II__ ,• , 11 -- I B'MIN. PLAN SECTION A -A 1. MAX. KEYED CONST.JOINT MIN L-VARIABLE - MAX. 20' •-i WMPEC GUTTER L B• 2•_6•• �B B• 3'-p" 2•' APPROACH h Z S BARS A GUTTER a� ti ------- --� -" I- -- ---- ------- 'l B S C I IEARS _ 0 .. --r-- BMSF BARSE Ira iV °• --° }�/��\\ I NF3" DIAMETER BARS E \t /f i WEEP HOLE FRONT ELEVATION BARS F B" 1'-8" B•• BARS B - - --���//- - (GUTTER REMOVED) 11A.. 3'-0•• B•, 5X'/,' BENT PLATE SECTION B-B TYPE A NOSE DETAIL SHALL BE USED WITH CG-3 6 CG-7 STANDARDS < ° _ ,/' R w L2yi'X21/2"XI/4' GALVANIZED TYPE B NOSE DETAIL SHALL BE USED WITH 00-2 & CC-6 STANDARDS. TYPE A TYPE B /i'X 4" STUD SHEAR CONNECTOR WELDED GALVANIZED PLATE FOR TYPE A TO BE BENT ON AN AGE OF 68.30' TO ANGLE IRON AT 2'C-0. CONNECTORS AND IS TO BE ANCHORED WITH �I/x" X 4" STUD SHEAR NOSE DETAILS WELDED TO BENT PLATE AT 2-C-C. 2„ APR. PAVEMENT DI-3A ,. �_ DI-M 1 L DI-3C L WARPED PAVEMENT ph x Foil x I/\ I ---FLOW --FLOW �L.WIL I ,'`{i_s/�, 1 1 DETAIL WHEN USED FOR USE ON GRADES ADJACENT TO CURB FOR USE IN SAGS WITHOUT GUTTER BOTH SIDES TO BE SYMMETRICAL -tVDOT SPECIFICATNIN ROAD AND BRIDGE STNJDARO6 STANDARD CURB DROP INLET REFERENCE SHEET 1 OF 2 REVISION DATE 12" - 30" PIPE MAXIMUM DEPTH 1H> 8' z33 .....,. 06,10 VIRGINIA DEPARTMENT OF TRANSPORTATION 302 SEE STANOMAD SL-1 FOR A+PLICMEITY OF SAFETY SLABS. B STANDARD MIA-1 NOTES 1 FRAME M COVER THE TOP OF MASONRY IB MI BE LEFT L -+ SUFFICIENTLY LOW TO PERMIT PROPER GRADE ADJUSTMENT OF COVER AND FRAME TO BRIDE S THE USE OF MORTAR OR BRICK AS DEDUCTED BY THE ENGINEER. 302 ST-I J- -' B�A DIAMETER-4'•B"+(2 x WALL THICKNESS) _h SECTION B-B BRICK CONCRETE OR CONCRETE BLOCK Cf•SN B NDTEI MIN, 60' DIAMETER MANHOLE REQUIRED. MANHOLE PVC CROSS T USE APPROVED FLEXIBLE RUBBER GASKETED STOP COUPLING 27' PIPE STRAPS (STAINLESS STEEL) SPACED EVERY 2' VERTICALLY _-90' RESTRAINED BEND E • ". . ! " ^ - ^ ICON ' SEWER i. 4" PIP E PLAN RM'Mlr PROFILE MIN, 6' BEDDING WITH NO. 68 STONE 1. HEIGHT OF THE VERTICAL DROP PIPE WILL BE DETERMINED BY THE ACSA, BUT SHALL NOT BE LESS THAN TWO (2) FEET. 2. VERTICAL DROP PIPE SHALL BE SDR 26 P.V.C, SIZED THE SAME AS THE INCOMING PIPE AND CONNECTED TO THE DROP FITTING WITH STANDARD GASKETJOINT. 3. VERTICAL DROP PIPE SHALL BE STRAPPED TO THE MANHOLE AT PIPE JOINTS. STRAPS SHALL BE MADE OF STAINLESS STEEL. 4. SHAPE INVERT AS NEEDED TO PROVIDE SMOOTH TRANSITION FROM DROP CONNECTION DISCHARGE POINT TO SPRING LINE OF MANHOLE INVERT. S. DROP CONNECTION DISCHARGE FITTING SHALL BE ORIENTED AT45 DEGREES, INTO THE FLOW. 6. VERTICAL DROP PIPE SHALL BE INSTALLED AT 90 DEGREES FROM THE ACCESS STEPS, 7. MINIMUM 72" DIAMETER MANHOLE REQUIRED FORA SINGLE SO" OR 12" DIAMETER DROP CONNECTION, OR TWO 8" DIAMETER DROP CONNECTIONS. STANDARD INTERNAL DROP CONNECTION N.T.S. FIG. S-1-C2 IS-1 mlllll,1 HALF SECTION A -A (WITH FRAME AND COVER REMOVED) BRICK CONCRETE NOTES. 1. QUANTITIES SHOWN ME FOR MANHOLE WITHOUT PIPES. THE AMOUNT DISPLACED BY PIPES MUST BE DEDUCTED TO TMLE OF QUANTITIES DEPTH BRICK MANHOLE CONCRETE ONNOLE BRICK I CONCRETE CONCRETE FEET THOUSANDS CU. YARDS CU. YARDS 4 0.5 0.785 1.437 5 0.7 0.785 1.888 8 0.9 0.785 1.961 7 1.0 0.785 2.223 B 1.2 0.785 2.485 9 1A 0.785 F747 O 1.6 0.785 3.009 11 1.9 0.970 3.455 12 2.2 0.970 3.817 13 2.5 0.970 4.179 14 2.8 0.970 4.541 151 3.1 1 0.970 4.903 18 1 3.4 1 0.970 17 1 4.0 1 1.173 6.032 INCREMENT 1 0.45 10.582 OBTAIN TRUE QUANTITIES. 2. A BASE THICKNESS OF 9" WAS USED IN COMPUTING CONCRETE QUAMRES. 3.INCREMENTS TO BE ADDED FOR EACH ADDITIONAL FOOT OF DEPTH. TRANSITION BETWEEN 4. MATERIALS MAY BE NMICK, CONCRETE OR PIPE DIAMETERS WHEN APPROVED CONCRETE MANHOLE BLOCK. DIFFERENT SIZES OF PIPES AREENCOUNTERED. 5. IF BLOCKS USED THE UM THCKESS OF OF SAME IS TO BE BE 5 ". OTHER THICKNESSES ARE TO CONFORM TO WALL THICKNESS SHOWN FOR CONCRETE. S.ALL CONCRETE TO BE CLASS A3. NOTES1 SHAPING OF MANHOLE AND INLET INVERTS IN ACCORDANCE WITH ]. WHEN SPECIFIED ON PLANS THE THIS DRAWING IS TO APPLY TO THOSE STRUCTURES SPECIFIED AVERT IS TO BE SHAPED IN ON PLANS OR WHEN INVERT OF PPE 6 MOVE AVERT OF ACCORDANCE WITH STANDARD IS-1. STRUCTURE. THE COST OF FURNISHING AND PLACING 1. ALL MATERIALS INCIDENTAL TO THE MANHOLE OR DROP INLET IS TO BE FORMED AND CONSTRUCTED SHAPING IS TO BE INCLUDED IN THE BO IN ACCORDANCE WITH APPLICABLE STANDARD OR SPECIAL DRAWING. PRICE FOR THE STRUCTURE. THE AVERT SHINING AS DETAILED HEREON IS TO CONSIST OF A D CEMENT CONCRETE MIX CONFORMING TO CLASS A3 OR CLASS Cl. EXCEPT THAT 25X OF COARSE AGGREGATE MAY BE CLASS JUNCTION BOXES, TRANSFORMER PADS, PEDESTALS, ETC. SHALL NOT BE LOCATED WITHIN THE RIGHT OF WAY., VARIES •-10'*-►I I+---10't WATER SEWER ,'a E LOCATION OF OTHER UTILITIES (GAS, ELECTRIC, TELEPHONE, CABLE, ETC,) EASEMENT WIDTHS, WATER OR SEWER ONLY - 20' MINIMUM WATER & SEWER 30' MINIMUM MI SEE PART 3, PARAGRAPH DI SEPARATION OF WATER & SEWER SYSTEMS, UTILITIES CROSSING A WATER OR SEWER EASEMENT SHOULD BE AT 90• TO THE RIGHT OF WAY, UTILITY LOCATIONS & EASEMENT WIDTHS VARIES VATER MAIN M.J. FITTING 4" DIP RESTRAINED JOINT FITTINGS NTS FIG, W-1 BOX TO METER BOX (SEE FIG. W-I THRU W-7E). i - -so I L--2" COPPER 4" PLUG THREADED FOR 2" COMPRESSION FITTING NOTES: • GATE VALVE WILL BE 4" UNLESS OTHERWISE SPECIFIED BY THE ACSA. SERVICE LINE TO CONNECT AT MAIN WITH XN4"T€E. • REFER TO FIG•W-3 FOR THRUST BLOCK DETAILS ON TEE. • REFERTO FIG. W-5 FOR THRUST BLOCK DETAILS AND DEPTH OF COVER ON GATE VALVE. • NO CONCRETE SHOULD BE POURED ON ANY PART OF THE RESTRAINED JOINT. USE PLASTIC SHEETING AS PROTECTION FOR BOLTS. ' • USE 250D P.S.I. CONCRETE. v- SLOPE TO DRAIN TO INVERT OF OUTLET PIPE SECTION A -A METHOD OF TREATMENT IN DROP INLETS �\ SLOPE TO DRAIN \, X TOUTLET PIPE F UP TO 4" IN DIAMETER AND CONSIST OF STONE, BK.ROKEN BTHE SURICK, • I• ry,U/' ..y:.o-:::^q . ��:: II II AC `�T SHIDILL BELEEFFTTETSAOOTH BY MEµS OF HAND ROWELLMD.RWNE MANHOLE FOR 12 - 48 PIPE CULVERTS ROAD AND BRIDGE STANDARDS OF THE COARSE AGGREGATE SHALL REMAIN EXPOSED. VIRGINIA DEPMTMENT OF TRANSPORTATION REVISION DATE SHEET 1 OF 5 DETAILS OF INVERT SHAPING AS SHOWN HEREON ARE FOR EXAMPLE -- ° PURPOSES ONLY. EACH MANHOLE OR DROP INLET IS TO BE SHAPED - 06.01 CONFIGURATION AND BEST THE HLINESPARTICULAR INLET AND OUTLET PLAN SECTION B-B METHOD OF TREATMENT IN MANHOLES `V(]OT SPECIFICATI ROM AND BRIDGE STANDARDS STANDARD METHOD OF SHAPING REFERENC MANHOLE & INLET INVERTS SHEET 1 OF REVISION DATE I 302 06.08 I VIRGINIA DEPARTMENT OF TRANSPORTATION LARGE METER SERVICE LINE NTS FIG. W-6C GALVANIZED STEEL STEP SEWER SERVICE LATERAL CONNECTION NOTES: 1. WHERE A SEWER SERVICE LATERAL CONNECTS TO A MANHOLE AND NO INVERT ELEVATION FOR THE SERVICE LATERAL IS INDICATED , THE TOP (CROWN) ELEVATION OF THE SERVICE LATERAL PIPE SHALL BE AT LEAST 0.2' HIGHER THAN THE TOP (CROWN) ELEVATION OF THE THE LOWEST PIPE CONNECTED TO THE MANHOLE. 2. SEWER LATERALS TAPPED INTO AN EXISTING SEWER MAIN SHALL BE CONNECTED USING A PIPE SADDLE. 3. MINIMUM GRADE FOR SEWER SERVICE CONNECTION SHALL BE 2% �Q (1/4" PER FOOT ) 4. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER 2' MIN DIAMETER OF 4". 5. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER OF 3 FEET. SALT TREATED FINISHED GROUND 2 x 4 MARKER PLUG END OF - MAIN LINE I SECTION SERVICE LATERAL IN LINE WYE-TEE PLAN 77 VARIES R SEWER SERVICE LATERAL CONNECTION N.T.S. FIG. S-2 NOTE: HYDRANT MUST BE EQUIPPED WITH CHARLOTTES- VILLE THREADS WHICH IS QTHE LOCAL STANDARD. 1 LENGTH OF BRANCH VARIES 8' MIN pf TO10'"-2ALVE BOX 7 CU. FT. III 68 STONE-1 : o .. ,. B" GATE • VALVE a" X 6" TEE 2500 P.S.I. CONCRETE ; •. 4,1., > ;y MO- ��i + BASE AND THRUST , ;•.• ;��.11. �i' , Is•, ' BLOCK AGAINST UNDISTURBED STABLE SOIL STEEL PILE WHEN THE SOIL IS DISTURBED OR WHEN RESTRAINED JOINT FITTINGS A HYDRANT IS LOCATED IN A FILL, IN ADDITION TO POURING CONCRETE, A STEEL PILE SHALL BE USED AS ADDITIONAL SUPPORT. NOTE 1. SURROUND WEEP HOLES WITH GRAVEL AND KEEP FREE OF CONCRETE. 2. MAINTAIN A 3 1/2' MIN. COVER FROM THE MAIN TO THE FIRE HYDRANT ( INCLUDING DITCHES ) 3. FINISHED GRADE SHALL SLOPE AWAY FROM THE FIRE HYDRANT AND VALVE BOX. 4, THE GATE VALVE IS ALLOWED IN SHOULDER OR BEHIND THE DITCH. IT IS NOT ALLOWED IN THE DITCH. S. FIRE HYDRANTS SHALL BE INSTALLED AT LOCATIONS WHERE WEEP HOLES ARE ABOVE THE PREVAILING GROUNDWATER ELEVATION. IF REQUIRED TO BE IN WET AREAS, THE WEEP HOLES SHALL BE PLUGGED AND THE HYDRANT SHALL BE PUMPED DRY. TYPICAL FIRE HYDRANT ASSEMBLY DETAIL ST-1 N4 GRADE 60, REINFORCING ROD ENCASED IN p CORROSION RESISTANT RUBBER OR OTHER MATERIAL APPROVED BY THE ENGINEER. (DIMENSION MAY VARY WITH MANUFACTURER'S DESIGN) CORROSION RESISTANT MATERIAL Fr- 11 REINFORCING ROD CAL SECTION M ALL STRUCTURES WITH A DEPTH OF OTHERWISE NOTED ON THE PLANS. E 41/y" FROM INSIDE FADE OF BE M" C-C. MINIMUM FORCE OF 300 POUNDS WHEN FADE OF THE SUPPORT. ALLY ALIGNED AND UNIFORMALY SPACED FORTHEENTIRE DEPTH OF ANY STRUCTURE. N PRECAST UNITS STEPS MAY BE CAST IN PUCE, MORTARED INTO HOLES PROVIDED BY THE FMMCATOR, OR DRIVEN. IF MINIMUM OF 3" EMBEDMENT STEPS DIFFERING IN DIMENSIONS, CONFIGURATION OR MATERIALS FROM THOSE SHOWN MAY ALSO BE USED PROVIDED THEY MEET THE MUMMA REQUIREMENTS SHOWN HEREON AND THE CONTRACTOR HAS FURNISHED THE ENGINEER WITH DETAILS AND CERTIFIED TEST REPORTS OF THE PROPOSED SUBSTITUTE AND HAS RECEIVED WFI TTEH APPROVAL FROM THE ENGINEER FOR THE USE OF SUCH STEPS. ALL STEPS INSTALLED SHALL BE PROVIDED WITH SLIP -RESISTANT SURFACES OR DIMPLED SUCH AS BUT NOT LIMITED TO, CCFRUGATED KNURLED, "ll S. &UMINw STEPS SHALL BE FABRICATED IN ACCORDANCE WITH ASTM 822%ALLOY 6005-T5. THAT PORTION OF THE STEP ENCASED IN MASONRY SHALL BE UNIFORMLY COATED WITH A BITUMINOUS, SOLVENT TYPE, ASBESTOS FILLED ALUMINUM PIGMENTED COATING CONFORMING TO FEDERAL SPECIFICATION TC-C-0049BA TEP STANDARD STEP VIRGINIA DEPARTMENT OF TRANSPORTATION ROM AND BRIDGE STANDARDS REVISION DATE SHEET 1 OF 1 LIOEO N.T.S. FIG. W-4 �J N z WATER PLACE 5' GALVANIZED " WITNESS " POST WITH CAPPED ENDS PAINTED BLUE IN REMOTE AREAS I AS DIRECTED. MARKER LOCATION MAY BE SUBJECT ;d TO HIGHWAY DEPARTMENT APPROVAL. FINISHED GRADE ADJUSTABLE TRAFFIC RATED VALVE BOX W/ LID M.J. GATE VALVE LINE 2500 P.S.I. CONCRETE •• P A 2'x 2' BEARING AREA. THRUST BLOCK d n D, c • � d • NOTE : IN REMOTE AREAS, VALVE BOXES SHALL EXTEND SIX (6) INCHES ABOVE GRADE. TYPICAL GATE VALVE NTS FIG. W-5 METER SIZE ➢IMENSION A DIMENSION B DIMENSIDN C 5'0' 3'B' 2' 3'1' S'0' ' 5' MIN, ' 4' 5' MIN. 12' MIN. 'MTNa GREATER THAN 4' P�P13SALS WILL BE SUBMITTED. B DOOR HINGES I I EF I I I I I I I I I I I I I LIFT HANDLE L---------------- TYPICAL METER VAULT N.T.S. FIG. W-7A SIDE VIEW t: !lf OF L 0 U CRAIG W J. KOTARSKI Lic. N0. 0402048507 .,,,6.02-0-1-22, M E O � O N vI N C >E 6E w w >, 3 LL o 3 Lu ILL- W O n W j U Z W J - Ui O a F- '� o U) x < LO u1 < o¢ 6� w z N 2 C N Z O =v>� In 1n N M w cj� a� W J Lri Iz 0 O U) 0 O lY 0 w w U C) a z O DATE n > cl� 0210712022 0 DRAWN BY R. VAN NIEKER DESIGNED BY • • J. DENKO • CHECKED BY C. KOTARSKI • • SCALE 75' DIAMETER DRILLED IDLE FOR TOUCH READ INITS TOP VIEW 3" DIAMETER FLAT 0 UNDDEERNEATH FACE ZL x 36' LATCH ACCESS Q ` ^ > J zQ� O2: LIJ w Q m I..L Q 06 LL 06 O z pC O 0 Z JOB NO. 46883 SHEET NO. C1.2 0 c a' J c L 21.11b KUAU tk 2016 ROAD & BRIDGE STANDARDS 1qIiv�ALTH per' CG-12 GENERAL NOTES: 1. THE DETECTABLE WARNING SHALL BE PROVIDED BY TRUNCATED DOMES. 2. ALL DETECTABLE WARNING SURFACE PRODUCTS SHALL MEET THE REQUIREMENTS OF SECTION 504 OF THE SPECIFICATIONS FOR CG-12 DETECTABLE WARNING SURFACE. DETECTABLE WARNING SUFACE PRODUCTS USED SHALL BE FROM THE MATERIALS APPROVED PRODUCT LIST NUMBER 72. 3. SLOPING SIDES OF CURB RAMP MAY BE POURED MONOLITHICALLY WITH RAMP FLOOR OR BY USING PERMISSIBLE CONSTRUCTION JOINT WITH REQUIRED BARS. 4. REQUIRED BARS ARE TO BE NO. 5 X 8" PLACED T CENTER TO CENTER ALONG BOTH SIDES OF THE RAMP FLOOR, MID -DEPTH OF RAMP FLOOR. MINIMUM CONCRETE COVER 1%". 5. ROADWAY CURB / CURB AND GUTTER SLOPE TRANSITIONS ADJACENT TO CURB RAMPS ARE INCLUDED IN PAYMENT FOR CURB / CURB AND GUTTER. 6. CURB RAMPS ARE REQUIRED FOR SIDEWALKS AND SHARED USE PATHS. THE WIDTH OF THE CURB RAMP SHALL MATCH SIDEWALK WIDTH. WHEN CURB RAMPS ARE USED IN CONJUNCTION WITH A SHARED USE PATH, THE MINIMUM WIDTH SHALL BE THE WIDTH OF THE SHARED USE PATH. 7. DETECTABLE WARNINGS SHALL EXTEND THE FULL WIDTH OF THE CURB RAMP LANDING FLOOR. 8. CURB RAMPS WILL BE INSTALLED AND LOCATED WITHIN PEDESTRIAN CROSSWALKS AS SHOWN ON PLANS OR AS DIRECTED BY THE ENGINEER. CURB RAMPS SHOULD NOT BE LOCATED BEHIND VEHICLE STOP LINES, LIGHT POLES, FIRE HYDRANTS, DROP INLETS, ETC. 9. RAMPS MAY BE PLACED ON RADIAL OR TANGENTIAL SECTIONS PROVIDED THAT THE CURB OPENING IS PLACED WITHIN THE LIMITS OF THE CROSSWALK AND THAT THE SLOPE AT THE CONNECTION OF THE CURB OPENING IS PERPENDICULAR TO THE CURB. 10. DETECTABLE WARNING SURFACE PANELS SHALL BE INSTALLED FLUSH WITH THE BACK OF CURB. 11. WHERE CURB RAMPS INTERSECT A RADIAL SECTION OF CURB AT ENTRANCES OR STREET CONNECTIONS THE DETECTABLE WARNING SURFACE SHALL HAVE v A FACTORY RADIUS OR BE FIELD -MODIFIED AS RECOMMENDED BY THE MANUFACTURER TO MATCH THE BACK OF CURB. SEE CG-12-INS PAGES 204.06 NOTE;COMPONENTS OF CURB RAMPS CONSIST OF THE FOLLOWING: HYDRAULIC CEMENT SIDEWALK (DEPTH IN INCHES, AREA IN SQUARE YARDS) CURB WHEN REQUIRED (CG-2 OR CC-3 IN LINEAR FEET) DETECTABLE WARNING SURFACE (AREA IN SQUARE YARDS) EACH OF THE ABOVE ITEMS IS A SEPARATE PAY ITEM AND SHOULD BE SUMMARIZED FOR EACH CURB CUT RAMP. SIDEWALK RAMP 12:1 MAX 48:1 MAX 4'B. 10:1 MAX TYPE A PERPENDICULAR 1 y 5'MIN Y 2�_ 12:1 MAX TYPE B PARALLEL AND 204.07 FOR METHODS OF INSTALLING DETECTABLE WARNINGS ON A RADIUS. 4• NqN sw AT , 2" HIGHER THAN EDGE OF PAVEMENT AT )K 2( , SAME AS TOP OF CURB TYPE C PARALLEL & PERPENDICULAR TRUNCATED DOME .6"-2.4" C-C o I O O O O O z L 0 0 0 O 0 O O O O O O O - 0 0 0 0 0 0 0 0 0 0 0 O LANDING RAMP 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 + v 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 r "! 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 io 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 50%-65% OF BASE DIAMETER 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOP DIAMETER DETECTABLE WARNING ri SEEAT BNOTEACK O CURB •,� ARE9. ETER I _ VARIABLE FULL WIDTH OF RAMP FLOOR _ I- PAY LIMITS DETECTABLE WARNING TRUNCATED DOME DETECTABLE WARNING INSTALLED ON A RADIUS DETAIL DETAIL XV00T A COPY OF THE ORIGINAL SEALED AND SIGNED DRAWING IS ON FILE IN THE CENTRAL OFFICE. SPECIFICATION ROAD AND BRIDGE STANDARDS CG-12 DETECTABLE WARNING SURFACE REFERENCE SHEET 1 OF 5 REVISION DATE (GENERAL NOTES) 105 502 204.01 04119 VIRGINIA DEPARTMENT OF TRANSPORTATION 504 nndc Mr An R EIMIM to arAKIMAMMC!l ORANGE PVC TUBE PLACED OVER STEEL PIPE 8" DIAMETER STEEL PIPE FILLED WITH CONCRETE PAVEMENT 2'-0" DIAMETER CONC. FOOTING PIPE BOLLARD DETAIL No Scale Foxe of Curb Invert Une r r� �606 J �. R•1.5' p R-/25' a a e 1pnAp a/�av�d a f .20 o e itG�� nW w c r ->•}. zro ro _ g .E FIGURE 5 - CURB AND GUTTER DETAILS' " The following notes apply to CG-6, CG-7 and Rolltop curb: 1. Curb and gutter may be precast of Class A4 hydraulic cement concrete or cast in place using Class A3 hydraulic cement concrete. �- 2. When used with stabilized, open -graded drainage layers, the bottom of the curb and gutter shall be constructed parallel to the slope of the sub -base courses and to the depth of the pavement but not less than the thickness shown. ROLL TOP CURB No Scale w Slope break for drainage, if req'd. R- 2 Feet e U if Back of Cab o iU l Inn LL If 1: 1 I ! ! i iij! I - QOnetr, Jointfo E Moinline Edge of Pavement Driveway Entrance Warp Transition Roll top curb Part Plan of Entrance Transition FIGURE 7 - ROLL TOP CURB ENTRANCE DETAIL CG-12 A •5 DOWELS, 8" LONGS AT 12" C-C , _.. C /F2j (SEE TABL TE) A LT/RANSITION GUTTER PAN SLOPE TO 20:1 THROUGH RAMP LENGTH BACK OF CURB 20:1 ,. PERMISSIBLE CONSTRUCTION JOINT B _12:1 MAX ,n (SEE 2� MIN' SECTION A -A DETECTABLE WARNING SURFACE SECTION B-B PAN MAXIMUM SLOPE 20:1 NOTES: 1. FOR GENERAL NOTES ON THE DETECTABLE WARNING SURFACE, SEE SHEET 1 OF 5. 2. THE REQUIRED LENGTH OF A PARALLEL RAMP IS LIMITED TO 15 FEET, REGARDLESS OF THE SLOPE. 3. GUTTER PAN SHALL BE A MAXIMUM SLOPE OF 20:1 AT THE RAMP OPENING. 4. DIAGONAL PLACEMENT IS NOT PERMITTED. TYPE B PARALLEL APPLICATION ROADWAY GRADE IN PERCENT MINIMUM RAMP LENGTH IN FEET 4" CURB 6" CURB 0 4 6 1 5 7 2 5 8 3 6 9 a a 12 5 0 15 6 14 15 ROAD AND BRIDGE STANDARDS SHEET 3 OF 5 REVISION DATE 204.03 04/19 Radius Return Warp curb probe to match drireuay entrance apron grode abMine last aaca eNe of apron ove invert Ins. Driveway Entrance Apron for Rolllop Curb Part Section A FIGURE 8 - ROLLTOP CURB ENTRANCE DETAIL SECTION '2a Mo . 120 MAX. � ?A 5' MIN 4' MIN WITH BUFFER STRIP [R PAN SLOPE RAMP LENGTH 5' MIN 7 00* �- 12�1 MAX. i� WITHOUT BUFFER STRIP EXAMPLE INSTALLATION METHODS SEE PLANS FOR LAYOUT CROS ONE DIRECTION WITHOUT BUFFER STRIP CROSS CROSSWALK TWO TWO DIRECTIONS SMALLER RADII WITHOUT BUFFER STRIP :OPY OF THE ORIGINAL SEALED AND SIGNED DRAWING IS ON FILE IN THE CENTRAL OFFII CG-12 DETECTABLE WARNING SURFACE TYPE B (PARALLEL) APPLICATION VIRGINIA DEPARTMENT OF TRANSPORTATION A N F p ONE DIRECTION WITH BUFFER STRIP r� SPECIFICATION REFERENCE 105 502 504 V CRMG W. J. KOTARSKI Lic. No. 0402048507 :,6,. 02-0-7-22, na, E CD N O N � o > E w v E -i L-, `� 3 LL 0 LL w o m 2 w L M Q J W U 00 J-Lri tti (0LU NN V Z Y X in Q 7 U a ry 2 U N Q C ui 0 0i N � M Cal J to F- (n O (D 0 2 F LJ w w_ U Q Z 0 in > 0 O N Z 0 f w I-_ DATE 0210712022 DRAWN BY R. VAN NIEKER DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE Cn J ULJ a I- Omo W 06 O 0 Cn Uj O Z JOB NO. 46883 SHEET NO. C1.3 0 d 0 3 c a D a0 c' x O �Z 20 O C N E 2 a 0 W ob a0 D O x� (7 0 Z m O m F m `of= �$ e .§ d 2 YE XN X 0 0. N 2 2 12 a 0 c E `o 0 m 0 0l a c �a 10 a 0 .00 ur . p, �N A 0 �o c V C n� w E F_ L o:n oawoeeo-vvecsei rmperrywvvwAan ouulaoeaa-ios-UZ.o-❑Aw.owg I rioaec on unzozz io:oo Nm I oydessica uenrco o / / 0 0 0 o J / 0 0 0 \ ° o° ° ° ° 0 0 0 0 \ \ ° tj . '0\o 0 0000— 00000000 00 �00oooOy 0/ 0\\0\ Q 00 oOOOO°o°\Cnm0O000 \o 00o�\Q0o 000° O°°°o°°°°�°00 00o000 00)000000 000 0O 00 \ 000 00 °/ 00 NT0HmOO 0 / /. / 0 0 ° o W0) 0 ° o° o° 0 \ 0 0°° o 0 0 0 > 0 0 0 0 0 ° o o° / \ A m y 0 0000 °°00 00 m / 000 o..L \ \ 1; o 00p 000o o0 0000o°Oo /\\ 0000 \ \ 0001 -7\ \ \ o ° ° 00 0 ° ° 00 \ \\\ °°00 \ T / / 0°// / J�\ ° o ° /� \o \ °,0 Z 0 °// // ° o,� �o °� \\ _ oo / \ \off \\\ °'°�� { / D 0 °//� o o o °/ �_ \ -0Qo o\ \ \ ° ° o 0 0 0 \ o Q \ o ° I °°� / .f�00 / ° ° ° \\ 0A\ \\ / o 0 0 0 0 0 0 / o ° / % a �` I \\\\�\ \ \\\ lJll I/ , \ °, 1 / / io°o \ >;t 0120 0 0 °% ° o� \° ° ° 0 0 0 0 0 0 o o o o o o a o--o — / _ ` `\\,t\ I I IIIII I I IIill I I I I II ^ = -- ��_�`/''//7 \\ �1111111111�11/' I1�\I lily\ III IIII `\1 ill I \\ \\` \\\ 11 U),_ \ _I\ I �- / // / / \ \ \ fn / CA 2 �� � � � — _% \ �I \\ \� III �, / / / / / J 1 I I I / / \ 2 \ m - m 1 \\ m \ \ / / m N A A -------_m0 WIT\ an L rq I'lic < 0_ \ `\ \ \ ■ — \ — ' "�/ / I I III I I I II Ilf�i I I 14 1 ¢ I I I III I I II 11 /illl'rl�l� I I I II I I QI 1'\`If 111 11 1 1 1 1 1 '/ / r \ \\\ / �// \\ I / // {r I I I I III //\/'�// I I I I IJ / I / I fill I III / II I I I)/// I I / _ — ` I 'I I ��l // /I l l ICI I I / / / ,/ \� ���� ��\ `\ \ `\ 1 I / III\ ' I I I I I Iq I 1 '\ ' I I �. I II'I I I I I 1 1 I I/ I/ / , / I I I I I I I / / / — \ \ \ , 11 I I / , It I I I I I I 11 \ I II \/'1\11' 1 1 II I I I I l I( I IS.ml I I// /I� I', I I l I 1//�\ \ 1 1 1 I \ 1 ��`R \ \ \ 1 N n�1 ml 1 1 I 1 ( I 1 \ . _ q-g \ \ [nl 2, it ; \ � \ , 1 � \ \ \\\ \ •\ \ \\ \ 1\ �^`�&' \ \ 1 I ru W I I \ 11\\ \ 1'\\ \ /\ \ \ \\ \ \ 1 1 1 \ \ \ \ it , O �Imlpyl v / I. I111 I111 \\\\1�\\\ \ �• „/ \ \\ I / /Q1 i I \\ �\ \ \ 1 \ 1 k \ \\111 II Io)�$ \MIR •�,' i TI m I I 1 ' I \ \ \ \ m Im�° ApO- / / / /Moot% ----�' I // \ II \ \ 11 1 \1 If If dH0 r O —dHO HO --- �dHO dH0/ it t d/y° tiwr0� 1 my� I I I I \ I vCO� O TIMMONS GROUP .•-':'•. \LSI> ` oeoa old i IIII r- in r �0rn 1 I I � � > �J >c�m Dr0 M z I Ga D � THIS DRAWING PREPARED AT THE YOUR VISION ACHIEVED THROUGH OURS. CHARLOTTESVILLE OFFICE 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 TEL 434.295.5624 FAX 434.295.8317 www.timmons.com _ 0 Z yM 0)o o R I O POINT COUNTY OF ALBEMARLE, VA N II m - O n " m a " A m � o o ti v a ? m O N ' O m DATE REVISION DESCRIPTION OVERALL EXISTING CONDITIONS PLAN These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express wdlten consent of TIMMONS GROUP. SCALE I"=20' SHEET 2.1�\ = SHEETC2.2 CURB SD CURB INLE 0 20' 40' REMOVE TREE TOF \\�1_— INVIN=419.6E REMOVE STRUCTURES& -----___---_ INVOUT=419.61- HARDSCAPES /-� ---__ -----/-----\` \I _ .11I-- -- _-_-_- --_-_-_- /iE/loEf T2�.all3///I ,( S�HE-'E T ---- - - - - -- tilSD CURB INLETW/MHDSAWCUTPAVEMENT c I 1 \ - - - - TOP=429 42' / //� ''------------------- `\ \ \ INV.1N=424.95JZRCP- �Hlii\/Illl�llt\\� %/�' /I ` - SDCURB \\ INV.OUT=421.92' 15"RCP - - -� I �. \ �\ INV.IN 422.80'13"RRCP \ Q _ \ ��_� �� _ _ SHE C25== _=HEE��2.6 ` IN .OUT=42�.60' 15"R6P - ` l _ - \\ a , \\ INV.OUT=416.�7'18"RCl1l\111%Jf/ � - �p INLET W/GRATE NOV.OUT=422.98' 15'RCP- - \\ SD CURB -INLET W/MHD � \ PERM. DR1N\ - TOP=2tF8.72' EASEMENT- / EYG�EPTIOI\f13; / ' r \ \ ` \ \ _ _ INV.IN=420.85' 15"RCS JL SEE VDOT PLAN \ / LIMITED/ / �/ _ - - - - -INV OUT=420.72' 15"RCP / ACCESS / / \ \ \ \ \ ` ---- \ -- /' EASEMENT l / \ ` \ \ \ \ _ _ - - \ — KEY MAP Al /' /' /' / ------- I \�\ PAVED WALK PAVED WALK --------"I /' — — — — ` \ 'FLARED END SECT40N PEI�M. DRAIN ' ' \ - ' _ \ INV.IN=435.53' 15"RCP 1 EASENIE(11T / — ( \==--7 -_---/---------- - - - - -- \ \ _ SEEVDOT�PLAN--------- - - - - -- \ i---'---- \ _ — — — — — — — — — — — — — — — — — — — ` \ _ — — ` TEMP. I \ \ --------------------------------- PROPOSED _ \ / 1 ` \ -SLOPE EASEMENT SEE VD_OT_PLAN CENTE''RLWE JK\TRAIL �EE\I�DO� PLAN PERM. PARK_ �-_, ___E9SEME1{If 1 SEE VDOT PLAN -- -- / _-- ----- X— X --- X_ X --- \— I — — — — — _ — _ _ _ — / PERM.PARK ----- — — — 1 EASEMENT TM 61-167C ' HELENA OTTILLIA WETSEL.ETALS-'--------------- _ 1 \ _---------- -- WB. 173, PG. 237 ,- _ 1 25.926 ACRES _ , z ------------- ---- 1 0 TM 61-10i7C - 25.926ACRES I a TM61-467 = 1.582ACRES--------------�'' 1 TOTAL ACREAGE = 27.508 ACRES AtiBEMARLE C\OUNT\Y GIS ALBEMARLE COUNTY GIS - _ \ COITICk L SLOPS - I ANA•GED CRITICAL SLOPES - PPkS�ECR�-VED REMOVE TREES I \ PER THIS PLAN (TI/ / < xl - - - \ \ \ �\' 2„WALNUT I I / I REMOVE FENCE 1 --------------\\\\ If 7 K/ 24" CHERRY RE / / /' ,' / d / I I / I I I I \ 1 I / / / I r / I I I I I I 1 / MATCHL)NE SHEET 11.3 1 LEGEND: ' 4 , U CIRMG W. J. KOTARSKI Lic. No. 0402048507 e,.02-0�-22, n E 0 o N N c > E w _Z ¢ V LL o LL (ifO L M < J U o W J —N H Lu d N N N v Z H Y R x g-< U) _ N = U > H < c '^ N � M OJ J CL O w t7 w r] DATE 02/07/2022 DRAWN BY R. VAN NIEKER DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE 1"=20' Q Z O H Lu CJ G w a < 0 o m 06 LL < (%) O ILL 0 7 O 0 � Q O 0 Z X W JOB NO. 46883 SHEET NO. C2.1 EL a m fe 0 0 0 s 3 a a 0 o rr n0 �N 00 a 02 c m a0 O w rr O Z Z m O d o = 0 `� o o a m m 2 Y � N X C 0.0 -Z O O 0 c E m 0 m 06 a c �a '0 a 0 m o m m U M m 0 c 0 0.E h w E L MHD / I I TOP=441.24' INV.IN=42M6=24"RCP 80-T37RUCTURE=424.04' \\ \ ' SD F( ARED END SECTION \ \ OUTLET=428.45' 1 — — — — I L \\ _ o \ ALBEMARLE COUNTY GIS — — — \ \ SD INLET W/GRATE / TOP=446 25' SCALE 1"=20' SH 0 20' 40' ` 1 1 CRITICAL SLOPES - MANAGED ✓OHN WARNER — — — \\ \ INV. IN=432.05' 24"RCP \\\ INV.OUT=431.80' 24"RCP / ------ - - PKWY \ — \ I \ _ --� J/----SEE --- EASEMENT-----------\ VD-OTPLAN�� \ - -----------------p - - ---------- — _-_ —/— I — C2.2 \ T C2.Fx _ \ \ -5HEET C2.6 KEY MAP �Y1ry - _- - - - - - - - - - - - - - - --- - - - - - - - - - o - - -_ _ _ _ - - - _ - _ _ _ _ ' _ ' �p.Jy- _ - \ \\�� \ \\ 17 6"MAPLE r \ PERM. PARK SD INLETW/GRATE ------ TOP=444.03' _ _ ' _ '---------------- EASEM�Ni INV.OUT�43-2.b3r15"RCP - - ' '---------------- PERM. DRAIN _ -ROb/Flf-- EASEMENT SEE VDOT_P-LAN Lu Lu W / �' '' — — \- -- - - -- Lu Z' �' i' — — — - I e 1 \ \ \ \ \ I OVERHEAD POWER LINES TO BE RELOCATED - _ - IN ACCORDANCE WITH POWER COMPANY \ PROPERTY LINE TO BE VACATED ��� _ - ' " REMOVE TREES X PER THIS PLAN(TYP) _ - - - - ------\\ \ EXCEPTION 8; ` \ 24" HOLLY ® REMOVE LID CORPORATIONOWEST COMMUNICATIONS \ 1 \ 1\ \ \ ' TM 61-167C D3613 PG. 352 REMOVE SEE E VDOT PLAN SHED " - HELENA OTTILLIA WETSEL ET ALS TM 61-167HELENA OTTILLIA WETSEL WB. 173, PG. 237 I ET ALS 25.926 ACRES 24" MAGNOLIA REMOVE WB 173, PG. 237 ' TM 61-167C 25.92 ACRES ® 1. 582 ACRES - - - - - - - - - \ \ \\\ \\\\\\ \\III \ \\1 \I TOTAL ACREAGE = 27.508 ACRES I SHRUBS ol ' I REMOVE SANITARY \ \ \ \ \\ I I \ \\ \\ ' CLEANOUT \\ ® 24"MAGI V / N IA � 48"MAPLE 24" CEDAR II 1 \\ \1 Uh \\ \ \\ \ REMOVE STRUCTURES ' & HARDSCAPE PER THIS PLAN (TYP) SHRUBS REM II pI IIIIII " 8DEC DEC REMOVE OVE OLLY WELL 1112S Y HIII II1 I / / HOUSE UCCO I I II Ij I I I / I II II I 1 I ' REMOVE FENCE / I� �X REMOVE POWER POLE � I / ' REMOVE POWER POLES I ® z REMOVE ' I 24" HOLLY I / HEDGE I/ ' OVE / ®36" MAPLE SHED �� o ® 38" DEC 12"DEC / /' II /I1 I 1 1 1 I / ■ �� OHa ' �REM VE Sl OHp\ l If(14)10"-18" I ' OVE \ ® DECIDUOUS TREES SHED 15" CEDAR REMOVE POWER POLES ' REMO / \ \ \� ® ® 18" DEC MA I I ' MATCHLIN� SEE H ET C2.4 oyp\ \ \ - - /MAIL BOX jl / / / / / / / / omo m �'o ' v / / / / / kq LEGEND: REMOVE TREE REMOVE STRUCTURES & HARDSCAPES SAWCUT PAVEMENT SD CURB INLET W/MHD TOP=454.27' INV. IN=449.87'15"RCP INV.OUT=449.84' 15"RCP NLORA moo pR. U CFAIG W.1. KOTARs KI > Lic. No. 0402048507 :�.02-07-22,?,Q;-. Lm Z O Q- u U ui W Z O Lu W w DATE 0210712022 DRAWN BY R. VAN NIEKER DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE 1"=20' J a. Z O a\ / J zw L W �--� a 2 O m «s � a � D}ooL IL 7 O O V �F- V ) X w JOB NO. 46883 SHEET NO. C2.1 L SHEET Cf,, � _ SHEET C2.2 iJ 'SHEET 2.3/// / /y< t , / SHEE"FC2.4'Jw - - - ul/It \�I S`HEE EE1 C2.6 KEY MAP / LEGEND: REMOVE TREE REMOVE STRUCTURES & HARDSCAPES SAWCUT PAVEMENT SCALE 1"=20' MATCHLINE SEE SHEET C2.1 / / )• 1. 1. 1• 1• )t 1• )t 1• 0 20' 40' �/i,l�i,/l��'�/l� i,i,li,i,��)•i,i,ri,/��/i,l�i,i�'i,i,���i,i,/`i,i,,/i,�t�i,/ ' If If If/ / EMO 1 If r If 3 - W" 12" CHERRY/ It If REMOVE STRUCTURES L 1 ' ' THIS PLAN (TYP) / / / `•Wj / ! / / (3) 12" /15"CEDARS / 36" WHITE OAK 6"HOLLY (2)12" CEDARS / ® 36" PARADISE I / ® 36" CHERRY REMOVE TREES PER THIS PLAN (TYP) If If I / / I I /I / ■ I / If w I It/ I/ AL6EMARLE COUNIfY GIS STEP SLOPES ( P) \ / / / I I I I I I / ' I \ ' ' ' /ui TM 61-167C (� HELENA QTTILLIA WtTSEL ET ALS " Wp. 173, PG. 2�37 . \ 25.926 ACRES / I I 1 \ \ ' , / \ \ 1 I , / \ \ \ TM61-167C 25.926ACRES \ / I \ TM 61-167 1-582 ACRES ' / I \ \ TOTAL ACREAGE = 27.50-8ACRES If / / If If - 1 l /I-------- / If If ----------------------- IIt /-- ' — — — — — — — — — — — — — — — _ //I / \� ' \\ \--——————————————————— — — — — —— If If '\ 1 / — — — — — — — _ — —--_—— — — — — —— I \— -----------————————— — — — — —— — — — — — — — — — — — — — — — — — — — — — — — — — — — — _ _ _ _ - ALBEMARLE COUNTY GIS - - - - - - - - - -- - MANAGED SLOPES (TYP) \ --- _ - -- \ \ \ Ilk' '\m mm mm_m'''m'm--m�m m' IIim�-mwmm m-mmm m�w mm mm�''''im'1♦ M\m�m MUM _ _ MATCHLINE SEE SHEET C25\ — — — \ \ \ \ \ \ \ \ \ \ \ --- ---- \,,i \ .l`I"�,p.L7xL OF CRAIG W. I. KOTARSKI Y Lic. No. 0402048507 , 02-0-22a; n E 0 o N N c > E w - Z Lu Qw+y+ 3 LL o a (ifO 2 M QJ000 W J —N hl d N N N Z(• Y� X oQ �v _ N = U > Lq cmrn O N � M a� OJ J f E H w DATE 0210712022 DRAWN BY R. VAN NIEKERP DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE 1"=20' zw olf I --I O w m Q 0° P--I z 0 u Q z 0 0 w 06 z 0 0 0 z VJ w JOB NO. 46883 SHEET NO. C2.3 L MATCHLINE?�-ET/ I ".2- ��SS`� ---------- -------------�Ha` �_ -- MAIL BOX I 0 I e Oy\ �7 CI I // _ �'- Z--------- REMOVE MAIL BOXES �I - - ' - - - - - - - - \ - 30" & 28" DEC - _ - / /}/ / / \ \ - _ _ - - PROPERTY LINE TO BE VACATED I ' \ \ OVERHEAD POWER -LINES TO BE RELOCATED IN ACCORDANCE WITH -POWER COMPANY / 20" CEDAR / T - WALL / EXCEPTION 8; OWEST COMMUNICATIONS CORPORATION I � D8. 3734 PG. 412 / --------------- / 26"DEC /-- /'P \\ SEE VDOTPLAN / HOLLY \ I o / i 1 TM 61-167C HELENA OTTILLIA WETSEL ET ALS WB. 173, PG. 237 25.926 ACRES 8 TM 61-167C 25.926 ACRES TM 61-167 1.582 ACRES N ' TOTAL ACREAGE = 27.508 ACRES U uj W�W w , z �J - - - -- /- i i i _ REMOVE WALLS REMOVE ` \ / G NTRAN I ` I I \ \ I I \ \ I c II II io 0 ' I 1 I I I I II I I I ' - \ RELOCATES\SIGN \1 I I v I 1 \ OVERHEAD POWER LINES TO BE RELOCATED o `\ IN ACCORDANCE WITH POWER COMPANY = \ \ \ EXCEPTION 7; CENTRAL TELEPHONE COMPANY OR VIRGINIA ` \ DB. 3734 PG. 412 1 SEE VDO\T PLAN \ bVERHEAD POWER LINES TO BE RELOCATED �N ACCORDANCE WITH POWER COMPANY \ \ STREAM (TYP) ' \ \ \I I \ I \ 7 � ��� � ■r s � ��- � -�-� � � � � �� � � � � � � � � � � � � � � � �. � � � � � � � III � s s s � s s s s s s = S S S S S S S S S S S \ \ \ \ \ \ \ \ \ \ MATCHLINE SHEET C2 6 / \ \ \ \ \ A - cz i°n r1iI D cn y SAWCUT EXISTING PAVEMENT ALONG PROPOSED LANEIMPROVEMENTS SCALE 1 "=20' 0 20' 40' 1 r Klm. REMOVE TREE REMOVE STRUCTURES & HARDSCAPES SAWCUT PAVEMENT 3HEETC2.1�\- SHEETC2.2 � ySHEETC2.4-Vt 'KIIII / Jill k\� Ill !I �/ � i/� C \ \ \ HEET C2.6= U CRAIG W. J. KOTARSKI Lic. No. 0402048507 .�,.02-0�-22, ui 0 0 x c7 0 x 0 w Lu a z 0 Ln 0 r CL O oc E H w a 0 DATE 0210712022 DRAWN BY VAN NIEK DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE 1"=20' Z O Q J zG w � w <o Om06 Q (%) 00 LL Z O C) z O U 0 Z VJ W JOB NO. 46883 SHEET NO. C2.4 L F- S:\103\46883-Wetsel_Property\DWG\Sheet\CD\46883-103-C2.0-EXIS.dvag I Plotted on 2/7/2022 10:56 AM I by Jessica Danko 0 0 N D CDm N 0 A 0 ` v / \ I \ \ I \ I I \ \ I \ I 1 I / I I 1 / I I 1 I I I T I al 1 I I � I 1 I / C/) / ' mom lid r , yNn�l /I n -Tj l G) ` o C„ I 1 I` j I I I II I I I I I I I I I P I I I I I I I I I I I I 1 I I / I It lilt IID IZ I �\ t I / /' ,' / \\ / , I x 0 I / It M/ / I If fit (IN I I 1 , I it N� y I�f �.� I II It I \ I N� 0)/ \ \ 1 I 1 I \ I 1 1 I ' \ I 1 I I I'I II 1 �' 11, \, \ II I'\ IN \, II vJ II w CA) I+ \ I I rrril I I I \/ Cl) Q \ \ ^^ vff J T . ^ \ \ / \ \ \ \ h \\� \\\ \ _ �� /' / �\ \\ \ \ \\ \\ \\I \ \\ \rn Ids m r \ \ /' \2i , ' / / m / O z D D m m O C nm m \ / ' / ' z �� \ \ / o// G m A m 3 cn n m m i MATCHLINE SHEET C2.6 TIMMONS GROUP .•-':'•. THIS DRAWING PREPARED AT THE YOUR VISION ACHIEVED THROUGH OURS. CHARLOTTESVILLE OFFICE 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 TEL 434.295.5624 FAX 434.295.8317 www.timmons.com _ N Z CA 0w yo o R I O POINT COUNTY OF ALBEMARLE, VA N r N m n " m n m O p � o 'n 2 Z ti v a 2 z z z A ` O N'n \ m DATE REVISION DESCRIPTION EXISTING CONDITIONS & DEMOLITIONS PLAN These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. F- S:\103\46883-Wetsel_Property\DWG\Sheet\CD\46883-103-C2.0-EXIS.dvag I Plotted on 2/7/2022 10:56 AM I by Jessica Danko dH0 dH0 /f 01 //, ,• mi n it II,IIII��JPI�IIillll,j�i=�\\\w 1111111111 I II�J;, 11,114�j,1 'II; � t I11I'/' w �� �,`�\' I � II I / 11) —�I//1\\ ` I I�\I \\\\\� �11 m i Irnl �\\\�\\ m D Dm m �Il'l ,� �Ir.,/ I 1 \) m I \\ \\� \I11\1j�N�I� n � O O �/. N II ' 1 \\N, I\ ' \ IV I 1\11 II�r NCI n m r<n �-' ' \ , 1\ < ;U m Z C / --I A ' - - m 00 MATCHLINE SHE! IET C215 ' I I / / `\ am gin,. m° 1 �? , N / \ / / , O — m\00 1 �m00\ 0)-- / JH0 HO/ �dHO \ \ \ dH0 dH0 '0 \ \ /nx \ / / o \ - , zm ' \ m / r' \ ` z \ g- ' / A m \ / 0 / 9 m / ` --- / z0 / < / / ------------- 0 - — — — — — — — — 0 TIMMONS GROUP .•-':'•. m K 0 m Cn x C to 0 0 o-I mm 0 X_ D� z� mG) mD O m mK Km mz z � D Or z G) on rn rn N Cr 00 y y r 0) W m � � C N)�\ V r rn co 1 1 1 1 1 1 1 1 1 1� 10 x Z 1r m fn m 1 -mi 1 \ 1 1 1 \ 1 O 1 \ z X ` Dx 1nm \ 000 0 \ v 1 zm 1 0 ; m r *z 1=inn U \ 00 \ 1 rum \ Am 1 nr 00 D� 1 z0 1 1 ,dHo 1 dy0— 1 "yo 1 10Ty�i�p�� - �7 THIS DRAWING PREPARED AT THE YOUR VISION ACHIEVED THROUGH OURS. CHARLOTTESVILLE OFFICE 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 TEL 434.295.5624 FAX 434.295.8317 www.timmons.com _ M N Z 0)yo o w R I O POINT COUNTY OF ALBEMARLE, VA N r N m n " m n m O p , o m 2 z ti v a 2 z z A ` O v i \ m DATE REVISION DESCRIPTION EXISTING CONDITIONS & DEMOLITIONS PLAN 1 1 1 1 1 1 1 1 1 1 1 1 1 These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. EROSION AND SEDIMENT CONTROL NARRATIVE: PROJECT DESCRIPTION THIS PROJECT INCLUDES THE CONSTRUCTION OF 11 APARTMENT BUILDINGS, 15 TOWNHOUSES AND CLUB HOUSE AND ASSOCIATED UTILITIES AND SITE WORK. LIMITS OF DISTURBANCE IS 18.44 ACRES. 22. ONCE CONSTRUCTION IS COMPLETE AND ALL CONTRIBUTING AREAS ARE STABILIZED, EROSION CONTROL MEASURES CAN BE REMOVED UPON APPROVAL FROM THE E&S INSPECTOR. CONTRACTOR SHALL PROVIDE ALL INFORMATION REQUIRED FOR CONSTRUCTION RECORD DRAWINGS: Ior;7V, LTH per' '7 ADJACENT PROPERTY THE WESTERN AND NORTHERN PROPERTY LINE IS BOUND BY JOHN W WARNER PARKWAY. THE EASTERN PROPERTY LINE IS BOUND BY RIO ROAD. THE SOUTHERN PROPERTY LINE IS BOUND BY THE RIO COMMONS DEVELOPMENT, THE CHARLOTTESVILLE WALDORF SCHOOL, AND CITY OF CHARLOTTESVILLE PUBLIC OPEN SPACE. EXISTING SITE CONDITIONS CURRENTLY THE SITE HAS RESIDENTIAL HOUSE AND A VARIETY OF SHEDS AND A VACANT GRASS PASTURE. PERMITTING THE OWNER SHALL OBTAIN ALL REQUIRED STATE AND FEDERAL PERMITS INCLUDING VDEQ INDIVIDUAL PERMIT, VRMC GENERAL PERMIT, OR US ACE NATIONWIDE PERMIT (WETLAND IMPACTS) ETC. OFF -SITE AREAS NO OFFSITE AREAS WILL BE DISTURBED AS PART OF CONSTRUCTION. CRITICAL EROSION AREAS ALL CRITICAL SLOPES ARE SHOWN ON PLAN SHEETS C2.1, C2.2, C2.3, C2.4, C2.5, C2.6, C4.1, C4.2, C4.3, C4.4, C4.6. SILT FENCE WILL BE INSTALLED ON THE UPSTREAM END OF CRITICAL SLOPES WITHIN THE LIMITS OF DISTURBANCE TO DEMARCATE AND PROTECT THE SLOPES. EROSION AND SEDIMENT CONTROL MEASURES UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE CONSTRUCTED AND MAINTAINED ACCORDING TO MINIMUM STANDARDS AND SPECIFICATIONS OF THE CURRENT ADDITION OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. THE MINIMUM STANDARDS OF THE VESCH SHALL BE ADHERED TO UNLESS OTHERWISE WAIVED OR APPROVED BY A VARIANCE BY LOCAL AUTHORITIES HAVING JURISDICTION. STORMWATER RUNOFF CONSIDERATIONS ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE MAINTAINED IN ACCORDANCE WITH VESCH AND THE CONSTRUCTION SEQUENCE, INCLUDING THE INSPECTION OF ALL MEASURES AFTER ALL RAIN EVENTS. A LEVEL 1 WET POND, AND SIX BIOFILTERS WILL BE CONSTRUCTED FOR THE PURPOSE OF ADDRESSING WATER QUANTITY REQUIREMENTS. AT LEAST 75% OF NUTRIENT TREATMENT WILL OCCUR ONSITE. THE REMAINDER WILL BE PURCHASED STRUCTURAL PRACTICES: 1. TEMPORARY CONSTRUCTION ENTRANCE - 3.02 A TEMPORARY CONSTRUCTION ENTRANCE SHALL BE PROVIDED AT THE LOCATION INDICATED ON THE PLANS. IT IS IMPERATIVE THAT THIS MEASURE BE MAINTAINED THROUGHOUT CONSTRUCTION. ITS PURPOSE IS TO REDUCE THE AMOUNT OF MUD TRANSPORTED ONTO PAVED PUBLIC ROADS BY MOTOR VEHICLES OR RUNOFF. 2. SILT FENCE BARRIER - 3.05 SILT FENCE SEDIMENT BARRIERS SHAL L BE INSTALLED DOWNSLOPE OF AREAS WITH MINIMAL GRADES TO FILTER SEDIMENT -LADEN RUNOFF FROM SHEET FLOW AS INDICATED. ITS PURPOSE IS TO INTERCEPT SMALL AMOUNTS OF SEDIMENT FROM DISTURBED AREAS AND PREVENT SEDIMENT FROM LEAVING THE SITE. 3. STORM DRAIN INLET PROTECTION - 3.07 STONE FILTERS SHALL BE PLACED AT THE INLET OF ALL DRAINAGE STRUCTURES AS INDICATED ON PLANS. ITS PURPOSE IS TO PREVENT SEDIMENT FROM ENTERING THE STORM DRAINAGE SYSTEM PRIOR TO PERMANENT STABILIZATION. 4. DIVERSION DIKE - 3.09 A TEMPORARY RIDGE OF COMPACTED SOIL TO DIVERT WATER FROM A CERTAIN AREA. 5. SEDIMENT TRAP - 3.13 A TEMPORARY BARRIER OR DAM WITH A CONTROLLED STORMWATER RELEASE TO DETAIN SEDIMENT -LADEN RUNOFF FROM DISTURBED AREAS IN "WET" AND "DRY" STORAGE LONG ENOUGH FOR THE MAJORITY OF SEDIMENT TO SETTLE OUT. 5.1. MAINTENANCE OF SEDIMENT TRAP - INSPECT TRAP EMBANKMENT WEEKLY TO ENSURE IT IS STRUCTURALLY SOUND AND HAS NOT BEEN DAMAGED DURING CONSTRUCTION ACTIVITIES. ADDITIONALLY THE TRAP SHALL BE CHECKED AFTER EVERY RAINFALL EVENT. ONCE THE SEDIMENT HAS REACHED THE DESIGNATED CLEANOUT LEVEL IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. 6. SEDIMENT BASIN - 3.14 A TEMPORARY BARRIER OR DAM WITH A CONTROLLED STORMWATER RELASE STRUCTURE FORMED BY CONSTRUCTING AN EMBANKMENT OF COMPACTED SOIL ACROSS A DRAINAGE WAY 7. OUTLET PROTECTION - 3.18 STRUCTURALLY LINED APRONS OR OTHER ACCEPTABLE ENERGY DISSPATING DEVICES SHALL BE PLACED AT ALL OUTLETS OF PIPES OR PAVED CHANNEL SECTIONS. 8. DUST CONTROL - 3.39 DUST CONTROL IS TO BE USED THROUGH THE SITE IN AREAS SUBJECT TO SURFACE AND AIR MOVEMENT. VEGETATIVE PRACTICES: 1. TOPSOIL (TEMPORARY STOCKPILE) - 3.30 TOPSOIL SHALL BE STRIPPED FROM AREAS TO BE GRADED AND STOCKPILED FOR LATER SPREADING. STOCKPILE LOCATIONS SHALL BE LOCATED ONSITE AND SHALL BE STABILIZED WITH TEMPORARY SILT FENCE AND VEGETATION. 2. TEMPORARY SEEDING - 3.31 ALL DENUDED AREAS WHICH WILL BE LEFT DORMANT FOR MORE THAN 30 DAYS SHALL BE SEEDED WITH FAST GERMINATING TEMPORARY VEGETATION IMMEDIATELY FOLLOWING GRADING OF THOSE AREAS. SELECTION OF THE SEED MIXTURE SHALL DEPEND ON THE TIME OF YEAR IT IS APPLIED. 3. PERMANENT SEEDING - 3.32 FOLLOWING GRADING ACTIVITIES, ESTABLISH PERENNIAL VEGETATIVE COVER BY PLANTING SEED TO REDUCE EROSION, STABILIZE DISTURBED AREAS, AND ENHANCE NATURAL BEAUTY. 4. SOIL STABILIZATION BLANKETS & MATTING - 3.36 A PROTECTIVE COVERING BLANKET OR SOIL STABILIZATION MAT SHALL BE INSTALLED ON PREPARED PLANTING AREAS OF CHANNELS TO PROTECT AND PROMOTE VEGETATION ESTABLISHMENT AND REINFORCE ESTABLISHED TURF. MANAGEMENT STRATEGIES 1. PROVIDE SEDIMENT TRAPPING MEASURES AS A FIRST STEP IN GRADING, SEED AND MULCH IMMEDIATELY FOLLOWING INSTALLATION. 2. PROVIDE TEMPORARY SEEDING OR OTHER STABILIZATION IMMEDIATELY AFTER GRADING. 3. ISOLATE TRENCHING FOR UTILITIES AND DRAINAGE FROM DOWNSTREAM CONVEYANCES IN ORDER TO MINIMIZE PERIMETER CONTROLS. 4. ALL EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE MAINTAINED UNTIL THEY ARE NO LONGER REQUIRED TO COMPLY WITH THE CONTRACT DOCUMENTS OR STATE LAW. PERMANENT STABILIZATION ALL NON -PAVED AREAS DISTURBED BY CONSTRUCTION SHALL BE STABILIZED WITH PERMANENT SEEDING IMMEDIATELY FOLLOWING FINISHED GRADING. SEEDING SHALL BE IN ACCORDANCE WITH STD. & SPEC. 3.32, PERMANENT SEEDING. SEED TYPE SHALL BE AS SPECIFIED FOR "MINIMUM CARE LAWNS" AND "GENERAL SLOPES" IN THE HANDBOOK FOR SLOPES LESS THAN 3:1. FOR SLOPES GREATER THAN 3:1, SEED TYPE SHALL BE AS SPECIFIED FOR "LOW MAINTENANCE SLOPES" IN TABLE 3.32-D OF THE HANDBOOK. FOR MULCH (STRAW OR FIBER) SHALL BE USED ON ALL SEEDED SURFACES. IN ALL SEEDING OPERATIONS SEED, FERTILIZER AND LIME SHALL BE APPLIED PRIOR TO MULCHING. SEQUENCE OF INSTALLATION PHASE I (SEE SHEET C3.3, C3.4, C3.5, C3.6, C3.7, C3.8, C3.9, C3.10) 1. A PRE -CONSTRUCTION MEETING IS REQUIRED WITH ALBEMARLE COUNTY E&S INSPECTOR, CONTRACTOR, OWNER, AND ENGINEER. THIS MEETING SHALL TAKE PLACE AT THE COUNTY OFFICE BUILDING. CLEARING LIMITS MUST BE FLAGGED PRIOR TO THE MEETING WITH ONE (1) WEEK OF NOTICE. 2. INSTALL CONSTRUCTION ENTRANCE. SHOULD THE TEMPORARY CONSTRUCTION ENTRANCE NOT BE MAINTAINED PROPERLY OR AN EXCESSIVE AMOUNT OF SOIL BE TRACKED ONTO THE PUBLIC ROADWAY, THEN A PAVED CONSTRUCTION ENTRANCE, WATER TANKER TRUCK WITH PRESSURE WASHERS, AND SETTING AREA MAY BE REQUIRED BY THE EROSION CONTROL INSPECTOR. 3. INSTALL PERIMETER SILT FENCE AND TREE PROTECTION ALONG LIMITS OF GRADING. 4. INSTALL SEDIMENT TRAPS AND SEDIMENT BASIN PER PLAN. 5. INSTALL DIVERSIONS DIKES TO DIRECT RUNOFF TO THE TRAPS AND BASIN. CONTRACTOR TO ENSURE POSITIVE DRAINAGE. STABILIZE ALL AREAS AFTER INSTALLATION. 6. AFTER ALL MEASURES ARE IN PLACE, CONTRACTOR TO COORDINATE INSPECTIONS AS REQUIRED BY THE COUNTY OF ALBEMARLE. 7. CLEAR AND GRUB THE PROJECT AREA AND BRING SITE UP TO GRADE. A STOCKPILE AREA HAS BEEN INDICATED ON THE PLAN FOR USE BY THE CONTRACTOR. 8. SEED ALL DENUDED AREAS PER VESCH STANDARDS. PHASE II (SEE SHEET C3.11, C3.12, C3.13, C3.14, C3.15, C3.16, C3.17, C3.18) 9. AS CONTRACTOR BRING SITE UP TO GRADE - CONSTRUCTION ROAD STABILIZATION MAY BE REQUIRED IF DEEMED NECESSARY. 10. KEEP THE PHASE 1 DIVERSION DIKES IN PLACE AS LONG AS POSSIBLE. MAINTAIN POSITIVE DRAINAGE TOWARDS SEDIMENT TRAPS AND BASIN TO FULLEST EXTENT POSSIBLE. AS ONCE SEDIMENT BASIN IS BROUGHT OFFLINE, DIVERT WATER AS NECESSARY TO REMAINING TRAP OR BASIN. ENSURE THAT NO SECTION OF SILT FENCE IS OVERLOADED. 11. INSTALL UTILITY NETWORKS PER PLAN. 16. INSTALL INLET PROTECTION WHERE SHOWN ON THE PHASE II EROSION AND SEDIMENT CONTROL PLAN AND AS THE STORM SYSTEM IS CONSTRUCTED AND BECOMES OPERATIONAL. 17. ADJUST DIVERSION DIKES AND REMOVE SEDIMENT TRAP AS UPHILL DRAINAGE AREAS ARE STABILIZED AND HAS BEEN APPROVED BY ESC INSPECTOR FOR REMOVAL. 18. COMPLETE GRADING, INSTALL CURB AND GUTTER, AND BUILDING PADS. 19. ONCE THE STORM NETWORK IS FULLY ONLINE, CLOSE REMAINING SEDIMENT TRAPS. 20. ALL STORMWATER PIPING & STRUCTURES SHALL BE INSPECTED FOR SILT/SEDIMENT. IF PRESENT, SILT/SEDIMENT SHALL BE CLEANED OUT FOR THE SYSTEM TO THE SATISFACTION OF THE E&S INSPECTOR. 21. APPLY PERMANENT SOIL STABILIZATION TO AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS ACHIEVED. MINIMUM STANDARDS: AN EROSION AND SEDIMENT CONTROL PROGRAM ADOPTED BY A DISTRICT OR LOCALITY MUST BE CONSISTENT WITH THE FOLLOWING CRITERIA, TECHNIQUES AND METHODS: MS-1. PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT FOR LONGER THAN 30 DAYS. PERMANENT STABILIZATION SHALL BE APPLIED TO AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN ONE YEAR. MS-2. DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILES AND BORROW AREAS SHALL BE STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION OF ALL SOIL STOCKPILES ON SITE AS WELL AS BORROW AREAS AND SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE. MS-3. A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON DENUDED AREAS NOT OTHERWISE PERMANENTLY STABILIZED. PERMANENT VEGETATION SHALL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT IS UNIFORM, MATURE ENOUGH TO SURVIVE AND WILL INHIBIT EROSION. MS-4. SEDIMENT TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND -DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. MS-5. STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES AND DIVERSIONS IMMEDIATELY AFTER INSTALLATION. MS-6. SEDIMENT TRAPS SHALL BE DESIGNED AND CONSTRUCTED BASED UPON THE TOTAL DRAINAGE AREA TO BE SERVED BY THE TRAP. A. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT TRAP SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA AND THE TRAP SHALL ONLY CONTROL DRAINAGE AREAS LESS THAN THREE ACRES. MS-7. CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION. SLOPES THAT ARE FOUND TO BE ERODING EXCESSIVELY WITHIN ONE YEAR OF PERMANENT STABILIZATION SHALL BE PROVIDED WITH ADDITIONAL SLOPE STABILIZING MEASURES UNTIL THE PROBLEM IS CORRECTED. MS-8. CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY OR PERMANENT CHANNEL, FLUME OR SLOPE DRAIN STRUCTURE. MS-9. WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION SHALL BE PROVIDED. MS-10. ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT -LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. MS-11. BEFORE NEWLY CONSTRUCTED STORMWATER CONVEYANCE CHANNELS OR PIPES ARE MADE OPERATIONAL, ADEQUATE OUTLET PROTECTION AND ANY REQUIRED TEMPORARY OR PERMANENT CHANNEL LINING SHALL BE INSTALLED IN BOTH THE CONVEYANCE CHANNEL AND RECEIVING CHANNEL. MS-12. WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED, PRECAUTIONS SHALL BE TAKEN TO MINIMIZE ENCROACHMENT, CONTROL SEDIMENT TRANSPORT AND STABILIZE THE WORK AREA TO THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION. NONERODIBLE MATERIAL SHALL BE USED FOR THE CONSTRUCTION OF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE USED FOR THESE STRUCTURES IF ARMORED BY NONERODIBLE COVER MATERIALS. MS-13. WHEN A LIVE WATERCOURSE MUST BE CROSSED BY CONSTRUCTION VEHICLES MORE THAN TWICE IN ANY SIX-MONTH PERIOD, A TEMPORARY VEHICULAR STREAM CROSSING CONSTRUCTED OF NONERODIBLE MATERIAL SHALL BE PROVIDED. MS-14. ALL APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS PERTAINING TO WORKING IN OR CROSSING LIVE WATERCOURSES SHALL BE MET. MS-15. THE BED AND BANKS OF A WATERCOURSE SHALL BE STABILIZED IMMEDIATELY AFTER WORK IN THE WATERCOURSE IS COMPLETED. MS-16. UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: A. NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. B. EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. C. EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF -SITE PROPERTY. D. MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION. E. RESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THESE REGULATIONS. F. APPLICABLE SAFETY REGULATIONS SHALL BE COMPLIED WITH. MS-17. WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION SHALL APPLY TO INDIVIDUAL DEVELOPMENT LOTS AS WELL AS TO LARGER LAND -DISTURBING ACTIVITIES. MS-18. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE LOCAL PROGRAM AUTHORITY. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. MS- 19. PROPERTIES AND WATERWAYS DOWNSTREAM FROM DEVELOPMENT SITES SHALL BE PROTECTED FROM SEDIMENT DEPOSITION, EROSION AND DAMAGE DUE TO INCREASES IN VOLUME, VELOCITY AND PEAK FLOW RATE OF STORMWATER RUNOFF FOR THE STATED FREQUENCY STORM OF 24-HOUR DURATION IN ACCORDANCE WITH THE STANDARDS AND CRITERIA LISTED IN SECTION 19 OF VIRGINIA ADMINISTRATIVE CODE 9VAC25-840-40 MINIMUM STANDARDS. GENERAL EROSION AND SEDIMENT CONTROL NOTES: ES-1: UNLESS OTHERWISE INDICATED, CONSTRUCT AND MAINTAIN ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL PRACTICES ACCORDING TO MINIMUM STANDARDS AND SPECIFICATIONS OF THE LATEST EDITION OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK AND VIRGINIA REGULATIONS VR 625-02-00 EROSION AND SEDIMENT CONTROL REGULATIONS. ES-2: THE CONTROLLING EROSION AND SEDIMENT CONTROL AUTHORITY WILL MAKE A CONTINUING REVIEW AND EVALUATION OF THE METHODS AND EFFECTIVENESS OF THE EROSION CONTROL PLAN. ES-3: PLACE ALL EROSION AND SEDIMENT CONTROL MEASURES PRIOR TO OR AS THE FIRST STEP IN CLEARING, GRADING, OR LAND DISTURBANCE. ES-4: MAINTAIN A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN ON THE SITE AT ALL TIMES. ES-5: PRIOR TO COMMENCING LAND -DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO, OFFSITE BORROW OR WASTE AREA), SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE ARCHITECT/ENGINEER AND THE CONTROLLING EROSION AND SEDIMENT CONTROL AUTHORITY FOR REVIEW AND ACCEPTANCE. ES-6: PROVIDE ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY THE RESPONSIBLE LAND DISTURBER. (MODIFIED NOTE) ES-7: ALL DISTURBED AREAS SHALL DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND -DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT. ES-8: DURING DEWATERING OPERATIONS, PUMP WATER INTO AN APPROVED FILTERING DEVICE. ES-9: INSPECT ALL EROSION CONTROL MEASURES DAILY AND AFTER EACH RUNOFF- PRODUCING RAINFALL EVENT. MAKE ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES IMMEDIATELY. SOILS INFORMATION: 21B - CULPEPER FINE SANDY LOAM, 2 TO 7 PERCENT SLOPES. 40 TO 79 INCHES TO PARALITHIC AND LITHIC BEDROCK, WELL DRAINED. HYDROLOGIC SOIL GROUP: B 21C - CULPEPER FINE SANDY LOAM, 7 TO 15 PERCENT SLOPES. 40 TO 79 INCHES TO PARALITHIC AND LITHIC BEDROCK, WELL DRAINED. HYDROLOGIC SOIL GROUP: B 22C3 - CULPEPER FCLAY LOAM, 7 TO 15 PERCENT SLOPES. 40 TO 79 INCHES TO PARALITHIC AND LITHIC BEDROCK, WELL DRAINED. HYDROLOGIC SOIL GROUP: B 48E - PHILOMONT SANDY LOAM, 25 TO 45 PERCENT SLOPES. MORE THAN 80 INCHES TO RESTRICTIVE FEATURE, WELL DRAINED. HYDROLOGIC SOIL GROUP: A COUNTY OF ALBEMARLE k Deparnnent of Community Development Construction Record Drawings (As -built) for VSMP The following is a list of information required on construction record drawings for stormwater facilities (reference Water Protection Ordinance 17-422). It is preferable that the construction record drawing be prepared by someone other than the designer. Please do not provide design drawings as construction record drawings. A. A signed and dated professional seal of the preparing engineer or surveyor. B. The name and address of the firm and individual preparing the drawings on the title sheet. C. The constructed location of all items associated with each facility, and the inspection records to verify proper dimensions, materials and installation. The items include, but are not limited to the following: 1. Inspection Records and photographs for pipe trenches and bedding, including underdrains. 2. Video Pipe Inspection for any pipes which are not accessible or viewable. 3. Updated Location with geo-coordinates of all facilities. 4. Verified Drainage Area maps for the drainage area treated, and for drainage to the facilities. S. Current physical and topographic survey for all earthen structures. Ponds should include a survey of the pond bottom. Surveys should verify pond volumes are per design. Corrections may be required for alterations from the design. 6. Plants, location and type. 7. Plans and profiles for all culverts, Pipes, Risers, Weirs and Drainage Structures - Display the installed type of drainage structures, culvert/pipe size, weirs, materials, inlets or end treatment(s), inlet and outlet protection, alignment and invert elevations compared to design. 8. Computations: For significant deviations from design, provide sealed computations verifying that the as -built condition is equivalent or better than design. 9. Ditch Lines - Display the constructed location of all ditch lines and channels, including typical sections and linings. 10. Easements - Show all platted easements with dead book references labeled. Facilities and drainage must be within platted easements. Provide copies of recorded documents. 11. Guardrail, fences or other safety provisions - Display the constructed location of all safety provisions; fences, guardrail, including the type, length and applied end treatments, compared to design. 12. Material layers - biofilter media, stone layers, sand layers, keyways and cores must be verified as to material types and depths. Include inspection reports, boring or test pit reports and materials certifications. Biofilter media most be an approved state mix. 13. Access roads - show location of access roads, surface treatment, drainage, etc, as applicable. 14. Compaction reports are required to verify fill compaction in dams. 15. Manufacturers certifications for proprietary BMP's certifying proper installation and functioning. U CRAIG W. I. KOTARSKI Lic. No. 0402048507 :�,. 02-07-22, ^� E 0 N OV N o > E w v Z LU L-, `� 3 LL 0 LL w O m 2 J Lm ,t U 00 W J -a, ui H L9L9 W N N v Z Y �x 9 oa �v U-) N N 2 U N . C o) o rn N � M a� OJ J to O x c7 0 x 0 w w_ x U z 0 U) 0 0 am O cc f f H w H Q 0 DATE 0210712022 DRAWN BY R. VAN NIEKERM DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE N.A. zw H� < O w m Q LL O° I..L O U (n J a w 0 06 U) w 0 Z J z 0 U z CwC G w U) 06 z O U) O w JOB NO. 46883 SHEET NO. C3.0 L 3 , L'TH OF PIPE OUTLET CONDITIONS SILT FENCE DROP INLET PROTECTION I 70' MIN. 51 EXISTING 1. SET THE STAKES. 2. EXCAVATE A 4'7C 4" TRENCH UPSLOPE A PAVEMENT 2 X 4" WOOD DROP INLET WITH ALONG THE LINE OF STAKES., �� aT O " A A 3' FRAME GRATE 6' U CRAIG W. J. KOTARSKI FILTER 6„ M MOUNTABLE BERM A CLOTH FRAME' 1.5' -� / j j < , _ = Lic. No. 0402048507 a� 02-0-7-22, ' (OPTIONAL) SIDE ELEVATION MAX- - � %� /J IIII I O� G 1� EXISTING GROUND " FLOW 4" SjOWAL � ado do 70' MIN. 3, �(�ri MIN. III I 3. STAPLE FILTER MATERIAL TO STAKES AND 4. BACKFILL AND COMPACT THE PIPE OUTLET TO FLAT WASHRACK T 10' MIN. B l GATHER -� EXCESS EXTEND IT INTO THE TRENCH. EXCAVATED SOIL. AREA WITH NO OPTIONAL i AT m E rn DEFINED CHANNEL PLAN VIEW 10 EXISTING 12' MIN. MIN. �J lJ CORNERS ° r4 v PAVEMENT PERSPECTIVE VIEWS a o VDOT #1 COARSE AGGREGATE B POSITIVE j 10' MIN. �- _ w °i La *MUST EXTEND FULL WIDTH OF DRAINAGE TO INGRESS AND EGRESS OPERATION SEDIMENT I IIII, IIII - FLOW - H IIu > 3 Q U TRAPPING DEVICE STAKE o PLAN VIEW - LL w O 0 %y FABRIC SHEET FLOW INSTALLATION ¢ u z � 12' MIN. 11 "` (PERSPECTIVE VIEW) w > o N T 3" MIN. IIII MIN. 2 L9 Lu ry d SECTION A -A FILTER KEY IN 6"-9"; RECOMMENDED - 3" MIN. it ' jd 3' I MAX 3 O ' v CLOTH FOR ENTIRE PERIMETER FILTER CLOTH SECTION A -A - \A , FLOW � v w DETAILA A A B\� U.)_ ry p z A ELEVATION OF STAKE AND FABRIC ORIENTATION - / - ¢> 6' 7„ A 3do (MIN.) SPECIFIC APPLICATION I C THIS METHOD OF INLET PROTECTION IS APPLICABLE WHERE THE INLET DRAINS A m RELATIVELY FLAT AREA (SLOPE NO GREATER THAN 5%) WHERE THE INLET SHEET OR POINTS A SHOULD BE HIGHER THAN POINT B. to F- do REINFORCED CONCRETE DRAIN SPACE OVERLAND FLOWS (NOT EXCEEDING 1 C.F.S.) ARE TYPICAL. THE METHOD SHALL NOT SECTION B-B APPLY TO INLETS RECEIVING CONCENTRATED FLOWS, SUCH AS IN STREET OR ui PIPE OUTLET TO HIGHWAY MEDIANS. DRAINAGEWAY INSTALLATION WELL DEFINED CHANNEL PLAN VIEW CE 3.02 IP 3.07-1 (FRONT ELEVATION) SF 3.05-2 c7 0 STONE CONSTRUCTION ENTRANCE STORM DRAIN INLET PROTECTION SILT FENCE (W/O WIRE SUPPORT) No Scale No Scale No Scale F La w w w 0 % ERNST CONSERVATION SEEDS 2 a Q _ d RIGHT-OF-WAY NON-NATIVE WOODS MIX - ERNMX-132 p DATE w SECTION A -A FILTER KEY IN 6"-9"; RECOMMENDED �_ GRAVEL CURB INLET SEDIMENT FILTER -�- COMPACTED SOIL CWD TO HAVE VDOT > 0210712022 CLOTH FOR ENTIRE PERIMETER BOTANICAL NAME COMMON NAME \f STANDARD EC-2 MATTING ON UPHILL p PRICE/LB 18" MIN. I I I I SIDE DRAWN BY NOTES: 1. APRON LINING MAY BE RIPRAP, GROUTED RIPRAP, GABION BASKET, OR o 30.00 k FESTUCA RUBRA CREEPING RED FESCUE 1.90 �^ - - t i l i t i t i t i i ~FLOW I _ ����I�- R. VAN NIEKER DESIGNED BY CONCRETE. 20.00% LOLIUM PERENNE, PERENNIAL RYEGRASS, 1.85 � �_ 2. La IS THE LENGTH OF THE RIPRAP APRON AS CALCULATED USING PLATES 3.18-3 AND 3.18-4. 'FASTBALL RGL' 'FASTBALL RGL' (TURF TYPE \IIIII / -ilill01� - • J. DENKO 3. d = 1.5 TIMES THE MAXIMUM STONE DIAMETER, BUT NOT LESS THAN 6 'CLIMAX' � //� 4.5' MIN. • CHECKED BY INCHES. 20.00% PHLEUM PRA TENSE, TIMOTHY, 1.20 'CLIMAX' • C. KOTARSKI OP 3.18-1 12.00% TRIFOLIUM HYBRIDUM ALSIKE CLOVER 3.25 DD CWD 3.09-1 • • SCALE OUTLET PROTECTION 12" GRAVEL FILTER TEMPORARY DIVERSION DIKE 10.00% AGROSTIS PERENNANS, AUTUMN BENTGRASS, 14.00 RUNOFF WATER WIRE MESH N.A. NO SC81@ No Scale ALBANY PINE BUSH - ALBANY PINE BUSH - FILTERED WATER • TABLE 3.31-13 NYECOTYPE NY ECOTYPE �:>,';" :'q :' • ACCEPTABLE TEMPORARY SEEDING PLANT MATERIALS •a "QUICK REFERENCE FOR ALL REGIONS" 8.00% AGROSTIS ALBA REDTOP 8.00 PLANTING DATES SPECIES RATE (LBS./ACRE) 100% MIX PRICE/LB BULK: $3.61 J _I I ���• •■� v SEDIMENT '� II < . ?'; ❑■■■ O■❑❑. SEPT. 1 -FEB. 15 50/50 MIX OF SEEDING RATE: 40-60 LB PER ACRE CONCRETE - - J DOOM■■■ ANNUAL RYEGRASS WOODLAND OPENINGS GUTTER CURB INLET (LOLIUM MULTI-FLORUM) 12. & 50-100 THE SHADE -TOLERANT GRASSES AND CLOVER ARE GOOD FOR GRAVEL SHALL BE VDOT#3, #357 OR 5 COARSE AGGREGATE. CEREAL (WINTER) RYE WOODLAND OPENINGS AND PARTIALLY SHADED SITES. MIX (SECALE CEREALE) FORMULATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DEPENDING ON THE AVAILABILITY OF EXISTING AND NEW PRODUCTS. WHILE THE FEB. 16 - APR. 30 ANNUAL RYEGRASS 60-100 FORMULA MAY CHANGE, THE GUIDING PHILOSOPHY AND FUNCTION OF SPECIFIC APPLICATION: THIS METHOD OF INLET PROTECTION IS APPLICABLE AT id U) LOLIUM MULTI-FLORUM ( ) THE MIX WILL NOT. CURB INLETS WHERE PONDING IN FRONT OF THE STRUCTURE IS NOT LIKELY TO CAUSE INCONVENIENCE OR DAMAGE TO ADJACENT STRUCTURES AND J MAY 1 -AUG. 31 GERMAN MILLET 50 TS (SETARIA ITALICA) 3.31 UNPROTECTED AREAS. I P 3.07- 6 PERSPECTIVE VIEW Q w 0 TEMPORARY SEEDING PLANT MATERIALS SLOPE STABILIZATION SEED MIX STORMWATER INLET PROTECTION yi Mtt 3 G,'r r"5 r fr Q J O No Scale I No Scale No Scale V O \ / (- TABLE 3.32-D o z _ Z SITE SPECIFIC SEEDING MIXTURES FOR PIEDMONT AREA BLOCK AND GRAVEL DROP INLET SEDIMENT FILTER 1eYtr ; �� Q TOTAL LBS. PER ACRE FILL SLOPE r ::; x ^ t O w LJ MINIMUM CARE LAWN EARTHEN RIDGE WARE" m /� COMMERCIAL OR RESIDENTIAL 175-200 LBS. - ,A°�C ETE 9" FABRIC ,L LINE POST `L Q 7 KENTUCKY 31 OR TURF -TYPE TALL FESCUE 90-100% IMPROVED PERENNIAL RYEGRASS 0-5% BLOCK _SCR - III IIIII ( IIIII (IIII IIII IIIII IIIII a METAL(TOR ��iMAX� GROUND M)POST OR MAX'(U)POSTS BRACING CONCRETE FOOTING Q LJJ KENTUCKY BLUEGRASS 0-5%5'MIN. (IIIII IIII IIIII - GENERAL SLOPE (3:1 OR LESS) - -IIII -IIIII III IIIII IIII III IIIII III PERSPECTIVE VIEW PERSPECTIVE VIEW PLASTIC FENCE METAL FENCE O=LJJ KENTUCKY 31 FESCUE 128 LBS. RED TOP GRASS 2 LBS. 2' U SEASONAL NURSE CROP ` 20 LBS. - 06 150 LBS. LOW -MAINTENANCE SLOPE (STEEPER THAN 3:1) FD 3.10-1 SF 3.10 Z ` SEE SLOPE STABILIZATION SEED MIX - VEL R� Q TEMPORARY FILL DIVERSION SAFETY FENCE (n WIRE SCREEN FILTERED O No Scale No Scale ���� WATER RUNOFF OVERFLGvv�,� ` USE SEASONAL NURSE CROP IN ACCORDANCE WITH SEEDING DATES WATER �� _ WITH Lij AS STATED BELOW: „ . SEDIMENT FEBRUARY 16TH THROUGH APRIL.................................. ANNUAL RYE ' ... MAY 1ST THROUGH AUGUST 15TH ............................ FOXTAIL MILLET •: DROP 1-I I I ElI I I El El AUGUST 16TH THROUGH OCTOBER ............................... ANNUAL RYE INLET J-Il-IJ-I NOVEMBER THROUGH FEBRUARY 15TH........................ WINTER RYE SEDIMENT ;>.' WITH GATE l ED -I I I 1-I ED I I 1- " SUBSTITUTE SERICEA LESPEDEZA FOR CROWNVETCH EAST OF FARMVILLE, VA (MAY THROUGH SEPTEMBER USE HULLED SERICEA, ALL STANDARD ORANGE VINYL OR PLASTIC CONSTRUCTION OTHER PERIODS, USE UNHULLED SERICEA). IF FLATPEA IS USED IN LIEU SPECIFIC APPLICATION: THIS METHOD OF INLET PROTECTION IS APPLICABLE FENCE ATTACHED TO POSTS (PRE -WEATHERED WOOD, OF CROWNVETCH, INCREASE RATE TO 30 LBS./ACRE. ALL LEGUME SEED WHERE HEAVY FLOWS ARE EXPECTED AND WHERE AN OVERFLOW CAPACITY GALVANIZED STEEL, IRON OR THICK PVC PLASTIC), AT LEAST MUST BE PROPERLY INOCULATED. WEEPING LOVEGRASS MAY BE IS NECESSARY TO PREVENT EXCESSIVE PONDING AROUND THE STRUCTURE. 40" ABOVE FINISH GRADE WITH SPAN BETWEEN POSTS NO ADDED TO ANY SLOPE OR LOW -MAINTENANCE MIX DURING WARMER GREATER THAN 6' ON CENTER. EVERY NINTH POST SHALL - SEEDING PERIODS; ADD 10-20 LBS./ACRE IN MIXES. GRAVEL SHALL BE VDOT#3, #357OR #5 COARSE AGGREGATE. CONTAIN A WARNING SIGN THAT CLEARLY IDENTIFIES THE IP 3.07- 3 FENCE AS A TREE PROTECTION FENCE. TP JOB NO. 46883 PS 3 32 NO SCALE 3 38 PERMANENT SEEDING MIX FOR PIEDMONT AREA DRAIN INLET PROTECTION TREE PROTECTION SHEET NO. Flra:RM C3.1 No Scale No Scale L Table 11: Outlet Protection Design Table (ref. Va. Erosion and Sediment Control Handbook, spec. 3.18) OUTLET PROTECTION DESIGN apron on level ground Outlet Hydraulics Apron 0 2) ° o d N L C '4 N 6 N OIL0 C U 6 S1 .� x O N W O1 � 1Y N m EE `� A 0 0 M t a O Z v o 0 3 3 S rernarks 100 4 3.23 411.00 414.20 3.2 Max 12.0 1 22.4 20.0 pass I jWet pond outfall 200 3 37.00 414.13 422.14 8.0 Max 9.0 15.8 14.0 pass I Outfall into wet pond 300 1.25 3.17 414.28 422.14 7.9 Max 3.8 6.8 6.0 Class AI Outfall into wet pond 400 1.25 3.06 459.50 460.31 0.8 Max 3S 6.8 6.0 Class AI Outfall Into Bio 1C 500 1.25 1.93 456.03 454.49 0.0 Min 3.8 9.9 1 8.0 Class AI Outfall Into Bio 1E 600 1.25 1.29 459.50 460.31 0.8 Max 3.8 6.8 6.0 Class AI Outfall into Bio 1C 700 1.5 1.65 439.50 1 440.70 1.2 Max 4.5 8.9 8.0 Class AI Bio 2A outfalI 800 1.5 7.84 446 446.83 0.8 Max 4.5 8A 8.0 Class AI Outfall into Bio 2A RD Outfall 1 4.55 443.75 444.52 0.8 Max 3.0 6.6 6.0 Class AI Outfall into Bio 1A RD Outfall 1 1.37 456 454.5 0.0 Min JoT5 6.0 Class AI Outfall into Bio 1B N d � y � d 0 N n a W 0 o Class Al 0 - 1.1 Class 1 1.1 - 1.6 Class 11 1.6 - 2.2 Class 111 2.2 - 2.8 Type ll 2.8 - 4.5 Type 1 4.5 - Table 16: Sediment Trap design (spec 3.13) Sediment Trap design - #1 drainage area (acres) (<3) 2.59 trap volumes: volume elevation (ft) area (so volume(cy) cumulative (cy) 445 2275 446 3371 104.6 104.6 447 4562 146.9 251.5 448 5811 192.1 443.6 wet storage ORIGNA. GROUND [llV -SEE PUTE 113-1 ,• WMMRLC CREST OF STONE WEIR I wort• I DRY STORAGE WEI STORAGE (ODCAW.TED) vARvaT' ,FLIER CLOTH CTM:�RnI URa nn COMSE AGGREGATE cU I RPRIP wet storage required (cy) (67•DA) 173.5 bottom of stone weir (ft) 447.0 wet storage provided at this elevation (cy) 251.5 `"coarse aggregate shall be VDOT #3, #357 of #5 slope of wet storage sides 21 weir length (ft) (6xDA) 15.5 dry storage: bottom of trap elevation (ft) 445 dry storage required (cy) (67'DA) 173.5 bottom trap dimensions: 160k22' crest of stone weir 448.0 top of dam elevation (ft) 448 dry storage provided at this elevation (cy) 1921. top width of dam (ft) 2 slope of dry storage sides 2:1 top trap dimensions 180'x42' Table 16: Sediment Trap design (spec 3.13) Sediment Trap design - #2 drainage area (acres) (<3) 1.65 trap volumes: volume elevation (ft) area (so volume(cy) cumulative (cy) 437 1190 438 2045 59.9 59.9 439 3056 94.5 154.4 440 4123 132.9 287.3 wet storage ORICNAL CREST or STONE WEIR GROUND \ 4EV. -SEE RATE 3.13-t DRY STORAGE WET STORAGE (DICAwIED) VM,ALF �N �nawnr' �• IA1% I FLTR CLOTK DRM}IML GROUND EEEv COME AMAEGTE•' CUSS I RpUR wet storage required (cy) (67'DA) 110.7 bottom of stone weir (ft) 439.0 wet storage provided at this elevation (cy) 154.4 "coarse aggregate shall be VDOT #3, #357 of #5 slope of wet storage sides 21 weir length (ft) (6xDA) 9.9 dry storage: bottom of trap elevation (ft) 437 dry storage required (cy) (67`DA) 110.7 bottom trap dimensions: 122k1T crest of stone weir 448.0 top of dam elevation (ft) 440 dry storage provided at this elevation (cy) 132.9 top width of dam (ft) 2 slope of dry storage sides 2-1 top trap dimensions 140'x30' Table 15: Sediment Basin design (spec 3.14) Sediment Basin design MIN. 1' WI SPILLWAY 2' WITHOUT CREST OF EMERGENCY SPILLWAY drainage area (acres) 19.04 basin volumes: (using T contour intervals) DESIGN HIGH WATER (25-YFt. STORM 0".) elevation (ft) contour area (so wlume(cy) cumulative volume r-D.s• (cy) 413 2973 RISEN CREST 414 4629 140.8 140.8� STORAGE DEYIATERING 415 6479 205.7 346.5 WET sroRAGE 416 8520 277.8 624.2 417 10753 356.9 981.1 418 13205 443.7 1424.8 SEDIMENT OLEANOSTORAGE EONT DLIC t WET E CE0 C.Y./ ro 3. C.Y./ ACRE) E) 419 15882 538.6 1963.5 420 18782 641.9 2605.4 421 21904 753.4 3358.8 422 25204 872.4 4231.2 423 28589 996.2 5227.4 424 32074 1123.4 6350.8 425 35660 1254.3 7605.1 426 39346 1389.0 8994.1 wet storage: wet storage required (cy) (67•DA) 1275.7 design high water (25 year storm) 425.0 dewatering orifice elevation (ft) 418.0 top of dam (ft) 426.0 wet storage provided at this elevation (cy) 1424.8 top width of dam (ft) 10.0 available volume before cleanout (cy) (33"DA) 981.1 bottom of basin (ft) 413.0 cleanout elevation (ft) 417.0 approx. bottom dimensions: 27'x218' distance from cleanout to orifice (ft) (> 1') 1.0 upstream face slope: 3:1 downstream face slope: 3:1 dry storage: dry storage required (cy) (67'DA) 1275.7 baffles: No principle spillway crest (ft) 422.0 length of flow, L (ft) 218 total storage provided at this elevation (cy) 4231.2 effective width, We (ft) 27 diameter of dewatering orifice (in) 10.0 L / We (battles required if > 2) 8.1 diameter of flexible tubing (in) (orifice+2") 12.0 collars: No runoff. depth of water at spillway crest (ft) N/A 'from hydroCAD calculations slope of upstream face (Z:1) N/A slope of barrel (Sb) N/A Q 2yr 42.9 length of barrel in saturated zone (Ls) N/A Q 25yr 119.4 number collars required N/A dimension of collars N/A principle spillway: 422 available head (ft) 4.0 emergency spillway: No riser diameter (in) 54 bottom width (ft) N/A slope of exist channel (ft/ft) N/A trash rack (in) 72 minimun length of exit channel (ft) N/A barrel length (ft) 116 crest of spillway (ft) N/A head on barrel through embankment (ft) 1.4 diameter of barrel (in) 48 E EO TYPICAL ORIENTATION OF •(STABILIZATION SHALLOW • ON •SLOPES, PROTECTIVE COVERINGS MAY BE APPLIED ACROSS THE SLOPE. 11 d WHERE THERE IS A BERM AT THE BERM TOP OF THE SLOPE, BRING THE MATERIAL OVER THE BERM AND STEEP ANCHOR IT BEHIND THE BERM. SLOPE n=n-11-1r R='n'Inlrunn u nn nn nl. II n.nnnn nn-u- _::3.•ro.... ... • . SLOPES, APPLY PROTECTIVE COVERING PARALLEL TO THE DIRECTION OF FLOW AND ANCHOR SECURELY. BRING MATERIAL Y1=�1=1141=�1=1�-11 DOWN TO BEFOREA LEVEL AREA TERMINATING THE •TURN THE FLOW END UNDER 4" AND STAPLE DITCH AT 12" INTERVALS. IN DITCHES, APPLY PROTECTIVE COVERING II n1I�IT�PARALLEL TO THE DIRECTION OF • 'I IIn II IIniI R=nUSE CHECK SLOTS• . AVOID JOININGCENTER OF POSSIBLE.DITCH IF AT ALL SOIL STABILIZATION BLANKET (TREATMENT-1 No Scale TYPICAL VESCH TREATMENT - 1 (SOIL STABILIZATION BLANKET) INSTALLATION CRITERIA 011 TAMP FIRMLY CHECK SLOT 2" O JUNCTION SLOT rTAMF 2" F ANCHOR NOTES SLOT APPROXIMATELY 200 STAPLES REQUIRED PER 100 SQ. YDS. OF MATERIAL ROLL. ANCHOR SLOTS, JUNCTION SLOTS & CHECK SLOTS TO BE BURIED 6" TO 12". 12" MAX. 4:1 OR FLATTER 6" MAX. STEEPER THAN 4:1 1 EDGE AND END JOINTS TO BE SNUGLY ABUTTED I I I I III I (JUTE MESH WILL HAVE I I STAPLED LAP JOINT IN I LIEU OF EDGE JOINT) I I I I I 5' MAX. 4:1 OR FLATTER 3' 1 I MAX. STEEPER THAN I I I I CHECK SLOT I I I I I I I I 1"TO 2" I I I I I z I I I I I I I L7 If VAR.�t--VAR.yr STAPLE FORMED FROM NO.11 STEEL WIRE. CHECK SLOTS AT MIN. W C-C IT STAPLE MIN. LENGTH FOR SANDY SOIL. INTERVALS; NOT REO.'D WITH ALL COMBINATION BLANKETS FIRMLY O F- TERMINAL FOLD TAMP FIRMLY [---4„----j r SOIL STABILIZATION BLANKET (TREATMENT-1 No Scale L a U CRAIG W I. KOTARSKI Lic. No. 0402MS07 .�. 02-0-7-22, ^� E O N OV N C > E w v _ Z `I' 3LL LL 2 WQ ILO m EC Q U 0 W J 0..I U J -Ui ti L 9LUL 9 N ON v M I : Y 7 3: 0�x �_< U)= vN 2 U > IN Q . C U1 C,a' N � M a � DO J toF- Ui 0 cD 0 Of x 0 w w 2 Q z 0 U) > 0 0 N Z 0 f IsE DATE 0210712022 DRAWN BY R. VAN NIEKER DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE N.A. J_ Q W J QNN z _j J H� Q O O w U a Z 00 LL Lu lclL 0 U U) 06 Z O ONN L.I_ LU JOB NO. 46883 SHEET NO. C3.2 L Use permanent SWM riser and DiDe SCALE 1"=20' ISHEET CM I HEET C 4 EROSION CONTROL LEGEND LIMITS or aEARwe AND eRAomc > _--s:_ _ . . . . . DRAINAGE DIVIDE CURB 0 20' 40' SHEETC3.9 _ SOIL AREA DIVIDE coxsraurnoN Ex1RANCE 3.02 71 _�--___ / o o { _ 17/11 I,lll // - '/ % f SF SILT FENCE 3.05 O/vi/ KrN / —` —_ — — ----o�°/\ f—�I I—C%\ 1 / 3I—, 6� �\ �<i�NE(\// \\I II ODSSIPTBP ® IxLEvornoN 3.0> C.5 � o IT DIWR51ON DIKE 3.09 — — — — SD CUR o SHFFT C .10 I 1 \\ \ J / '`—1 `I seDlMErTRAP 3.33INV.iIo oINVOUT Gbo SDCURB INLET W/MHe o° II/ ° SEDIMENTNRGIN 3.140 o ' 0 \ TO 'o o/ � INV.IN422.803CP o o/ o =11 0 ouTeT PRoreCOON 3.10 �\0'o HET7INo p o o /°//° C38 —SP INLET W/GRATE o ° /°\/ TBMORARYSEEDING 331 0TOP=42,-46'_ INV.OUT=422.98'15'RCP— — SD CUR INLET W/MHD PERM. DR1N \ \ � � / \ \ � \ ` \ \ ` ` _ _ — — _ TOP=�J'P8.72' � � � — � \ \ \\` � \\\\l I / PS PERMANENTSEEDwc 3s2 EASEMENT INV.IN=420.85' 15"RCP / \ \ \ \ MD mumRlxG 3.3s EYG�EPTl9I\f 13; r \ \ \ SEE VDOT PLAN \ \ \ — INV OUT=420.72' 15"RCP \ AliC CJJ \ \ P- TREE PROOFMON FENCE 3.39 EY MAP TP T / / EASEMENT DUST CONTROL 3.39 — SUADIMCD wnH STAwuunoN BM AREAS STEEPER -AN 3:1 TO BE 3.36 IRANNET SOIL TYPE: 22C3 — — _ _ _ 'VIRGINIA EROSION AND SEDIMENT COMaOL HANDBOOK" SP'AFICATION NUMBER --— // \ SOIL TYPE:21B EXISTING PAVED WALKWAY — _ /"/ / /' MU— — — — CI \ \ VDOT PLAN CL / / /' \ l ' / _ PAVED WALK _ --- `------- -----------�--- — ------ --- --- \ TRAIL EASEME�T / / I / / / � \ \ \ \ — `-i - � / / 1 1 1 / / IN- -FLARED END SECT EASE PEI�M. DRAIN / // / / \ \ ' \ \ ` ` \ \ — 1NV.IN--43b.53' 15" SEE VDOT`PLAN / l r ' —� — — — — — — — — — — — — — — — — — — — — — — \ PROPOSED TEMP. I I \ \\————————————————— — — — — —— \\ \ \ ' SLOPE EASEMENT \ \ \ \ — SEE 11DOT PLAN I ` \ \ — \ \ \ ` \ — — — — — — CENTEI'RLWE JK TRAIL mom new, jmft� Iw------\ __ \ \ *41#� W \ \\ `\ I I I\ \i \ \ \ \\ \ z, \ \ \ \ \CONTRACTOR TO LIMI'F THE AMQUNIT OF C) \ \ \ DII>\TURBANCE TO THE EXTENT \ \ \ I \ Q \ \ \ \ \\ \NECESSARY FOR SANITARY SE\IIVER a� �I 'CONSTRUC�ON. RESTORE GRADEI I \ \ R , I \ \ \ \ \ \ \ \SEED AND STRAW \ \ \ I \ \ \ \ I \ \ \ \ \ \ \ \ \ \ DC PS \ \ \ \ \ ABEMAR E C\V UNTY GIS \ LE COUNTY GS pLBEMAAA CMTICkL SLOP S- QANAGED \ \ / �■\ T � \ _ � = � _ �/ ` \ C}21UCAL S6pPES -PRESERVED SF \\ IL \ I of T SEDIMENTRAP #2 _ 1 / 1.65 ACRE DRAINAG AREA / It TOTAL STORAGE REQUIRED: $22 CY / // TOTAL STORAGE PROVIDED: 287 CY TOP OF DAM ELEVATION: 4\40.0(S T�2 / / I 12 I d /��' I / I I 170 ,�ri / I I 1 c/ I / �/ / LIMITS OF DISTURBANCE = 18.44 AC \ \ `/ \1 PERM. PARK— \ _ / \ — — — — — — SEE VDOT PLAN _s— --— ----- ------ ---------------- X— — — -- -- --- --- --- -- --- --- — — ' PERM.; ------ --___ --_— — — — — EASEM DD WAM ' ' v \ TS SF ----- DC — _ C6 l ,u I / Z DD / I x ' 24 WALNUT / I _ I ' I SOIL TYPE: 216 SOIL T4E: 48E I I `I 4,WTS /— I I 1 I ISOIL TYPF�21C . I I I DC I— I / 24" CHERRY - SHED l I -� MATCHLINE SHEET 1;3.5 U CRAIG W. J. K0TARSKI Lic. No. 0402048507 6,.02-0-7-22, E 0 N OV N c > E w ° E Lu GO z R: LL o LL w O L M Q J U o .. d N N N Lu X g_< U) _ N = U > ~ C Lri o rn N � M a � W J ui 0 0 x c7 0 x F 0 w Lu x Q z O Ln 0 O Y w DATE 0210712022 DRAWN BY R. VAN NIEKERld DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE 1"=20' Lij `T— v J ^_ LL L 1_ z z < O Q LuLL U d Q Z O o LL] � G O W 06 O ON L.I_ w JOB NO. 46883 SHEET NO. C3.3 c a c re 0 m 0 s 3 a a'O o cD ncD z 00 a 02 c m r- c m v, D.0 0 w Z zN 0 a �v `0� o a m m .Z Y N X C 0.0 2 ma 4� E m 06 c �a !0 a 0 m 0.o m U u 0 c 0 0.E h w E L SHEE\\\_ SHEET C'.4 EROSION CONTROL LEGEND MHD\ — LIMITS OFCLEARING AND GRADING - \ TOP=441.24' SOIL AREA DIVIDE INV.IN=42M6=24"RCP SHEET C3 9 _ BO-T-S RUCTURE=424.04' / \ \\ \II \\ i _ `_ ; :� ' \ J \ \\ \ i — .- I - CE CONnaurnoN ENIIurvCE 3.02 o 1\\\,/I// - I / / p { - saT FENCE 3.06 - O 1 —yll / � —— ' ® wLEr vaorernory 3.0> 2 \ \ p _ 1// - IP SHEET GlS i/I; SNEEf C3.6; ` /p° DIWR51ON DIKE 3.09 o SH C�.10 (�ll SEOIMENI TRAP 3.13 T -�-- \\ ° ° /�/ //Illy\\\`\ �z- \ SD F ARED END SECTION 1 ---_ / - \ \ ° o ° p \ _ _ - - \ \ \ DIMEN N sIN 3.14 N 4 1 rt------------------------------ OUT( ET=428.45' L_ - \ \ 0 0 p / y \\ \ \ \ SD INLET W p d p p / CC \ ALBEMARLE COUNTY GIS - - - _ - \ \ ° oa° '°" 3.'e 1 _ - _ \ \ TOP=446.25' o p 1° / \ 6/ /o /o HEE -ZHEE, _ - 1 CRITICAL SLOPES -MANAGED �O uN - - - \\ \ INV.IN=432.0 o p �o� _ _ \\ \\ 1 1 / / / / / / O 1EMPORARVSEEDING 3.31 /7 WARNER - - - _ / \ \ INV.OUT=43 ° p o _ ` \ \ \\ \\\l \I I I " \ I \ 1 PKWY \ PERMANENT SEEDING 3.32 �. MumeING 3.35 EX WRBLEY MAP Tp p_ TREE PR -.. FENCE 3.39 — _ _ _ — — — — _ — _ — — — _ / - - - \ DC Dusr CONTROL 3.39 — — _ _ — \_ _ _ — _ _ _ _ — — V _ _ — _ _ — _ _ _ — _ — — — _ _ — _ _ ' % / _ _ _ _ — ' — — — — — — — — _ .a \ \` \ SD CURB INLET W/MH BM A-1—EPER -AN 1:I To 11 3.36 PER DAWN- - _ _ - _ - _ _ BF NREzeD wnn srAwumnon _ -\\----- - - - - ------------ _ _ — _ _ - �� _ _r_ TOP=447.65' OwNKEr _ EASEMENT- - - - - -- ----- p — — — — — — — __- - --_ - — — — \ p �' (ft — — _ — — — -� _ — — — — — \ \ \ L \ _ i Ir lNVIN(S)=442.05' 15"R "VIRG[NIA EROSION AND SEDIMENT CONl0.°1 HANO80°K'SP'AFICAr10H NUMBER -� '/----SE€VDaTPLAN — — — — - — v — — — — — — — — — — -_ - -- _ �\ _ - - - - - _ _ - - _ _ _ _ I _ _ \\� \ INV. IN(N)=433.70'15"R ___-____ P_____________� -�o------- _ - - - - -- _ I_ — v \\\\� \\ \ INV.OUT=433.65'15"RC SCALEI"=20' -- - - -- ----- - ---- ---- - - - - o - _ — — _�-- __-_ \X \ IP 6"MAPLE --r--/ ' _ _ - - _ SOtL-TYPE: 22C3 \ �� ->•ff _ _ - --- -- ----- --- now / P _ SD INLET W/G TE --- - - ------\ ---- _ �_ _- — LIMITS OF DISTURBANCE - 18.44 AC / AEASEMM N-r / T .03' --- - - _�f - a — �\ INV.OUJ�42 5"RCP _ f i---------- _ ' ' a� S �' _-- EARS M.D f -2-1B _ / S i 1 \ \ \ 1 \ \now sM _ y _ - ROD �E: �-T--- / - DD / `\ w - - _----___- /' GAO _ i _ - - ♦ \� \ , \\ z TS k Rg2 r"d — _ - ' _ 1 \ \ / SD CURB INLET W/MHD TOP=454.27' F N50 - - INV. IN=449.87'15"RCP 458 �.� Q ' ' _ _ - \ \ \ \ INV.OUT=449.84' 15"RCP y _- SEDIMENT TRAP#1 0 -------- - - - - -- \ \ \\ / }\ 460 , 2.59 ACRE DRAINAGE AREA \� TOTAL STORAGE REQUIRED: 347 CY \��'� ) 462 TOTAL STORAGE PROVIDED: 444 CY _ _ - - - - - v \ TOP OF DAM ELEVATION:448.0 ----------------\_1\\ @ \ \ // / _ EXCEPTION 8; 24" HOLLY - QWEST COMMUNICATIONS CORPORATION I \ I\ \ / O� A R. ! 'S ! I 000 2'x2' CONC LID DB. 3613 PG. 352 \I� \\ r1 SEE VDOT PLAN- / ��' _----- SHED 24"MAGNOLIA \\ \\ \\ \\ I \\ \\ \\ /' �Ah.. I \ Z SHRUBS / - _ _ ' 4 MAGNOLIA ® 48" MAPLE 24" CEDAR 1 \ \ I V \ \ 1 SHRUBS '/ / a 18" DEC D II SF / I p 18" DEC 15" HOLLY WELL MOUSE 1-112 STORY STUCCO / / / I I II II i y L I I / ' 24" HOLLY HEDGE Ic II I I / 36" MAPLE SHED / Ip E oHP\�ZT 38-DEC 12"DEC _ O \ S \ \ errl� (14)10" / - \ DECID US TREES ❑ SHED 15" CEDAR _ _ - - PP k TS I / I off \ a 1 A I / n - / A _ O I III I I I 1 SHED _ ' ' - ` / DC SF I j P I�����,���r��>.��->•i��>•�>•ss>•ss>•t>•>•>•>•� MATCHLINE SEE HRaw ET C3.6 �yp- / — --- -- ' ' n.. - /ew.SC. U CRMG W. J. KOTARSKI Lic. No. 0402048507 e,.02-0�-22, n E 0 O3 0 N � N C > E °i E w Lu O " 3 LL LL o (ifO L Q J U 00 z w j -In O LL{/1 NN d V' W W M R 3:0 -) x In i w w x C N z O_ =U>m c ^ �_ N > M Lu Lu a� W J ui ui 0 0 x c7 0 x F 0 w w L U z O 0 O Y DATE 0210712022 DRAWN BY VAN NIEKER DESIGNED BY J. DENKO CHECKED BY -. KOTARSKI SCALE 1"=20' w Q 2 � 0N > L 1_ z z i--i < O Q wLL U Q Z wwC O O � G � Q O ``W Vn) 06 O w JOB NO. 46883 SHEET NO. C3.4 c a c f� 0 0 s 3 0- a 0 o cD ncD �z 00 a 0 c m- c m m o. 0 O w Z zm od a = 0 `� o a m m 2 Y 2B,° X C 0.0 -L. ° 2 Z m 0 c E m 0 m 06 a c 2c 0 a 0 m o m m U m 0 c 0 0.E h w E L EROSION CONTROL LEGEND ISHEEf \\ - �F HE ET C4 I I 1 //, I I' { . I -IMn50F CLEARING AND GRADING * % \\\\\ — _ ��+- e I I I I \ \ / 1 / 1 / MATCHLINE SEE SHEET C3.3 I t DRAINAGE DIVIDE I "7� SOIL AREA DIVIDE r SHEETC39< I CE CONSTRUCTION ENTRANCE 3.02_-- / / C� NqM $F snrEENCF 3.05 / o p -wC \ \1 I 1 // /0 t 7 i P• Y / CID OTARS)�- CRA'GW UL . No. 0402048507 -/�M IP mL aor rnox m p� _\ / /1 // A�02-O�-2: 15"' / y/y c / / SNEEfC3.6_ - ' / , / / SHED O oo t l\ /r // _�_ \ ,' I \ / l l / l / // ,' / // ' +�+5, �(C5 DD DrvE IDN DIKE 3.09 O\\\ I \ / SIO Y' ��'/ Ill '11//1 1 \\' / r/\\\C1 L // ' SHEET'P.10 / l� 1 11 1 \ // $T eDIMBrvrrR v 3.13 0 0 0�_. I llq I/�IIII I I I I l l l \ \ \ i/ //j `I ` - _ ' \ /// I $B seDlMExr xnsw 3.14 p / / O OP OUTLET PROTECTION 3.18 ° p / \ SF p ° /° / /0 /o HE 3.7 \�__ _ �;\\ H ��i��.� "� / / / E T$ TEMPORARY SEEDING 3.31 p 0\/ o -\ \ \� 1' T / / / / / / �6 / / \ / E J \\ \p \ I / / 3 4" 12" CHERRY/ W pg PERMANENTEEEDING 3.32 / / \ \ \ \\ , / / V Wo MIJ MULCHING 3.35 / / / / / �//// / / / / ' / , /� / / / i ' / / / / / / / / / \ \ / ' / � W L M Tp Tp_ TREE PROTECTION FENCE 3.38 / / / KEY MAP / / / / / ' / / / p / - - / > ,PERM. PARK / / / ' / / / / /' n N a DC DUST CONTROL 3.39 / EASEMENT / / / / / / / / / / (3) 12"% 15" CEDARS ' / / / ' / / / z H U ' x Sm TYPE: 4dE ./ / / / ' ' / 1 a � p � BM AREAS STEEPER THAN BaroBE 3.36 ,7, 36"WHITE OA STAMUZ D WITH STABILIZATION * "VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK" SPECIFrUnON NUMBER / / / / / / / \ / \ 1 \ / / ' ~ C DD N^ w SCALE 1"=20' M S" HOLLY / o w 0 20' 40' / / � / / / / / y / 1 1 / I � (2)12" CEDARS , / / / / 36" PARADISE / / / 4 ui O ( / ■ / 36" CHERRY / / je/ ' /� /\ /l i I , / I I /' / I / / / � � F w w 1 / `/ / / / 1 1 I I r I 1 / / / /' /` = Q ■ / / / / z LIMNS OF DISTURBANCE 18.44 AC > DATE / 02/07/2022 - I co 0 U r DRAWN BY I l� l I l , l 1 1 I , I I I l l l ' w R. VAN NIEKER w WDESIGNED BY � • J. DENKO / I I /I I I I I ■ I I / / / \ \ \ O W = CHECKED BY C. KOTARSKI Q I/ I 1 I I I I I I I \ \ \ \\ `// // '// // / / • • 1SCALE Ipj � I/ I I / / / \ 1 � I I I I I I \ \\ / / / / /' � • SOIL TYPE: 21 B \ ' / ww� /W / / Q SOIL TYPE: 21C /I /' ///// 1 I I I �/� \\ \\ \If - / / w Q \ \ l CDD --- --------------- > \> ` SF ---------- --- \ ---- z \ , Q O , , \ \ - - - - - - h - - \ O m U Q /I I I l I I / I / //I / \ \ L� ' ' - - - - - \ Z ----LL ------------ -- -- '/ O Z G - \ W ---------------------------------------- ` _ \ \ \\ O \ \ \ 1 c /) VOA \� \ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ - - _ / _ ' ' \ \ ` 1 \ \ \ \ \ I - _ _ - _ - - \ \ \ \ \ \ \ \ SO7L�YP€:21C _ \oso \ 1 \ \\\ \\ \\\ \\ SOIL TYPE:48E \------ - - - - -- \ \ \ \ \ / / ' \ \ \ \ \ \ 30B NO. 46883 SHEET NO. MATCHLINE SEE SHEET C3r7 \ \ \ \ --------------- c a c f� 0 m 0 3 a a 0 o cD n0 �N 0Z a0 o 2 c m r- c a0 O w O Z Z m O d a � m `0� o a 0 c .Z Y � N X C 0.2 -Z ° R C E 0 0 06 a c �a I0 a 0 m o m M U M C m c o 0 Is 00 h 0 �E ti - \ - - - - - - - I rccr MATCHLINE SHEET C3.4 / L v =L =_ IoHO - -� - - p MAIL I I--- BOX o STAGING, / z . ` se STORAGE AND - 1i I STOCKPILE AREA v / ONO -- ------ 30"&28"DEC- / 1 - - - SOIL TYPE: 21 B ' 20" CEDAR / �T �SOILTYPE21 --/ /// - _ WALL 1, f N 1 ' - / EXCEPTION 8; I - - - - - - - \ \ _ _ f,�WEST COMMUNICATIONS CORPORATION I I ' 0 26"DEC /k SEE VDOT PLAN / \ v HOLLY ` I a i \ I 4 ' I SF 1 _ I GRAVEL I I o \ ` ENTRANCE I 1 \I 1 TS M1 \ \ LLI 1 I mommum LLI 1 / �, \ W U Q V - I II IT o I, \\I \ \ \ lGN x \ I \ \ \ \ \\ r I \\ e � 1 ' U \ I - � EXCEPTION 7; e r CENTRAL TELEPHONE COMPANY OR VIRGINIA DB. 3734 PG. 412 r ♦ - SEE VDOT PLAN 1 I \ o 1 \\\ SF 1 I - 1 SOIL TYPE: 48E 1 � SOIL TYPE: 21 C SOIL TYPE: 21 B \ SOIL TYPE: 21 C ` \ 1 \ \ \ I e \ 1 \\ (C E \ 1 I CONCRETE \ / \ O \ \ 1 2 I I WASHOUT 44g I MATCHLINE SHEET C3.8 I O 0 o ° 0 0 ° o 0 0 O ° ° o 0 a JIA an NO ET C3.5 / / 1/Ic SHEEfC3.6 - - `�- ET EY MAP EROSION CONTROL LEGEND LIMITS OF CLEARING AND GRADING " . . . . DRAINAGE DIVIDE - I SOIL AREA DIVIDE - CE CONSTRUMON Ex1RANCE 3.02 SF SILT FENCE 3.05 Ip ® I. PROErnaN 3.02 DD DIVERSION DIKE 3.09 ST SEDIMENPTRAP 3.13 SB SEDIMENT BASIN 3.14 Op OUTLET PROTECTION 3.18 TS TEMPDRARY SEEDING 3.31 p5 PERMANENT SEEDING 3.32 3.35 X_Tp_muLCNIxG TREE PROTECTION FENCE 1.38 DC ous coma 3.39 BM AREAS STEEPER THAN 3:1 TO BE STABILIZED WITH STABNunoN 3.36 BLANKET —VIRGINIA EROSION AND SEDIMEM CONTROL HANDBWK' SPECIFICATION NUMBER SCALE 1"=20' 0 20' 40' LIMITS OF DISTURBANCE = 18.44 AC I U CRAIG W. 7. KOTARSKI Lic. No. 0402048507 e,.02-0�-2Z In E CD O N V N c > E w ° E Q LL y 3 a o U. K O L Q J U W w J — N M d N N N ui v Z H Y R x _ N = U > m c L^ 0 0+ N � M W J DATE 0210712022 DRAWN BY R. VAN NIEKER DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE 1"=20' T— U) ^_ LL NJ LL z z �< 0 Q w U d Q Z LL OOwwC � G O W 06 0 ONN L.I_ W JOB NO. 46883 SHEET NO. C3.6 0 N 0 s 3 a D 00 o X n0 �N 0Z a0 02 c m r- c La a0 O w O Z Z m 0 d 2 a w � m `0� �o a 0 c .Z Y N X C 0.0 -Z 2 N0 E m 0 m 06 a c ma 0 a 0 �+ o m � U mw h 0 CIS c 0 0.E h w E L F- S:\103\46883-Wetsel_Property\DWG\Sheet\CD\46883-103-C3.4-EROS1.dv✓g I Plotted on 2/7/2022 11:03 AM I by Jessica Danko \ MATCHLINE SHEET C3.10 i It 1 I 1 \ I \ / /rri Ili C/) II / m0o� r ZN�rnI / It \ 11V ^ v , 1 I \ 1 \ n \ r--- \ I T� \ I I I I I/ I \ I I I I I 1 I I I I /1 I I on I I I I I I I I 1 00 I, I I/ I I ---1 , I I D I II m 1 '1 111 1 II 190 I 1 1 1 1 I 1 ;II U) I I I -n I I 1 1 / I \ fill / / / / ' �\ / I I I 112 11 m I I tit I / / / /\ / / , I I �x 0 I / If \ I , \ , , /✓ // ,/ / / 1 r It it I I \ I I II I 1� Cn 1 1 I oN m \ 1 1 1 1 I I V ° ° ° ° ° Qm`�° ° \ m --& W o° y�0 0 10` \ b 000000� ��� \ \ i —1 \ \ Im /7 ! \\ \ nn \ i 1A L,I v v D n // f n \ lyl`v'II'l\ It TI—— / • \\vTJ \\ \\ ; ` II" I�'1iII\`:� \; 1 I NV \ \ \ \ \ \ \ \ I IIII 1I IIIII II IWit I�i` l I III I /\.1 \ \ \ \ \ \ ul O I \ \ -.j hw `�� \\111/l l/I Ilrl�' \ \ / \ -1 OJ\�I �\\Illilllll II\\\\�\�11, \\ /\\QI�\ \ ° / N• \ \ \-\ \ \ \ 1 m it\l ;mi lll' �II'�mn I \ �\\\I m — \ O\\ <�\ a r 00 s 5 g 3 0 \ \ m �a c $ - m g 0101 o \ \ �11 'll I m 11 1 \1 I \\ / // / / / // .N 3 s \ 1 I / / / / / m s / / a m v m s w s NATCHLINESHEETC�'.B I77 o THIS DRAWING PREPARED AT THE CO •• CHARLOTTESVILLE OFFICE °fib TIMMONS ROUP• • YOUR VISION ACHIEVED THROUGH OURS. y� n • 608 Preston Avenue, Suite 200 Charlottesville, VA 22903 y'09 0� ✓t TEL 434.295.5624 FAX 434.295.8317 www.timmons.com O N2 _ o RI O POINT ru m m A v 00 DATE REVISION DESCRIPTION No ^ ° n� V ej Z o COUNTY OF ALBEMARLE, VA it i NJ m a o z o m N iN� dlt�t�� w ERIOSION & SEDIMENT CONTROL - PHASE 1 �ti ` ° < m ` N� A These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express wdtten consent of TIMMONS GROUP. MATCHLINE SHEET C3.6 \ \ \ \ 448 I / - - - - - - - - 444 x° / \ I 442 440 / TS 436 432 \ ` —L430 IF \ \ \ �* \ co) / D V /SOIL TYPE: 21C ' SOILTYP.E'21B / \ \ SEDIMENT BASIN #1 14.69 ACRE DRAINAGE AREA \ TOTAL STORAGE REQUIRED: 2,551 CY TOTAL STORAGE PROVIDED: 5,656 CY \ S1131 TOP OF DAM ELEVATION. 426 418 \ vv vv \v 1 420 O DUNLORA FOREST _ _ p SUBDIVISION O \ \ n �44tp.LTII OF O CRAIG W. J. Y.OTARS KI > Lic. No. 0402048507 e,.02-07-22,4; m E 0 o N 6 N C > E v E w Lu LL L 3 LL U. o O Y L Q J U W Z w � —v3 O �{/1 raj d z H v Of U) Q U 0 w w x C N U Lq z O_ = c m o N i 2 M d et OE) J ui 0 0 x c� 0 x 0 w w U Q z O DATE IY 0210712022 0 0 DRAWN BY R. VAN NIEKER r DESIGNED BY • • J. DENKO • CHECKED BY C. KOTARSKI • • SCALE 1"=20' F7 w \ I I `' / SCALE 1"=20' LL'I /� \ \ \\ \ \ \ I I IDD 1 I J EROSION CONTROL LEGEND 11 / = LIMITS OF CLEARING AND GRADING AJ D , / I I DRAINAGE DIVIDE - ' i 1�11 SOIL AREA omDE CONSTRUCTION ENTRANCE 3.02 , / / I • �/ I OSSIPTF ® - OW E.-FENCE 3.05 QTM 61-1/67A INLET FRrernx 3.m RIO COM=lD3.DB. 5-085 PG. 6�� LIMyTS OF DISTJRBANCE=h8.44 AC SEGIMENTTRAP 3.13USE': DMRSION RESIDENTIAL Q GEDIMENTBAGIN 3.Ea > LJ— OUNET PROMMON 3.18 % J G TEMFOM SEEDING 3.31 O Q O /1 Lu m PERMANENT SEEDING 3.32 J d LL Z 1 MU muLcxlxG 3.36 0 SF 1 O TP 3p� TREE PR ErnaN FENCE 3.38 O 0 pC DUST COMOL 3.39 O U W BM AREAS STEEPER THAN 3:I TO BE 3.36 STABILIZED WRH STABILIIANON BL BIANKE06 -VIRGINIA ROSION AND SEDIMENT CONTROL HANDBOOK' SPECIFICATION NUMBER Z O SH T S ET Cab SHEETC3.9` o w o /ir pl S �'ET, 3-5 /I< \ J � ySI�EF�I`C3.6— SHEET C.10 q ;IIII I�IIIII,II/11111\\1�� 0 0� off\ Ilp I 1,�41,1III I11\ \ \ ; / /'I------ 0 \ 1 ' o �o /° /° \SHEET C = : _ \ S=F1E Ti C3.8/ 0 6 - — — \ \�\\\I�I�\\\ 1 \\ (/ / JOB NO. 46883 ZZ LEY SHEET NO. - LEY MAP C3.8 c a C f� ° 00 a aX o n" �z 00 o 2 C am -6 C @ @ C a0 0 d (� W .� Z zm od 2 a F @ `o� o o a @ m .Z Y 2° X C 0.0 L 2 m E m 06 0 a 9 Na !B a 0 m o m @ U C m ° 5E h w E L / / M _-' M — — — F Z i � / 2 PROPOSED TEMP. / SLOPE EASEMENT SEE VDOT PLAN mlg�/ ' ===mom \ Or 0000 \ PERM..,DRAIN \ EASEME ` ` SEE T PLAN / ' S F / / / �- - -- --- _———— — — — — —— — — — / --- / --——————————————— — — — — —— ' — — — — — — — _ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -41" z I N o 0 0 \ \ -7, 1 — — — — — — — — — — — — — — — — — — o 0 0 DC Z' 0 00 \ 01 , o / ° \ \ \ ° LIM CONTRACTOR -TO IT THE-AMT-0 OUNR - - - - - o \ \ \ \ 00 41116* 00 / / - - / r 6' / ` ^ / ' / DISTORSANCE TO THE EXTENT 00 \ \ \ \ \ \ \ 000 \ ` co SF __ \ / ' /' ' ' _ NECESSARY FOR SANITARY -SEWER — — \ ` J / / . ' / / / CONSTRUCTIOi4. RESTORE GRADE, / N o 1 1 \ o \ \ - - - -\ i' ' ^\ / ' / S�ED fcNI!rSTRAW. - - - - - ' ' / f / �,MAO / / \ LIMNTED ACCESS EASI�MENT SEE VDOT PLAN / 00 / ° 1 / - / \ / ° ° 0 ED 3 0 / 0 0�\ O CRAIG W. J. KOTARSKI Lic. No. 0402048507 .�,.02-0�-22, M E O O N N IZ C > E w 6E Lu Qw++ 3 LL o LL Y O L M Q J U W M1 d N N N Z H Y Lj 2i O x w U) _ N = U > m c Ln o rn N � M W J uri 0 0 x c7 0 x F 0 w Lu x a z O Ln 0 O Y SCALE V=20' 0 20' 40' CL / O O _ EROSION CONTROL LEGEND O ND GPADINGVDOTPJ_WCL LMITSOFCIF4RINGA ° ° \ ° — TR71L_EASEMENT DANAGEDEVIDE \ °SOILaREADIvIDE - oo ° ° CCONSTRUCONENRNCE 3.0" 2 O \O O > ° / I \ a~ 1 IP O ° ° ° o oSOIL TYPE:48E /' .ED o� o \\ \ \ \ \ R \ `�,� I \\ `--- \\ -�i SOIL TYPE: /'/� / / / / // // \, / / ° \\° ° \ \ \\�\\moo �\� \\`moo\ \ i� / / , 0 8 \ \� / / , ` / \ / OP \° o \ \ 1/ i / ro \ o o \\ \ \ `\ \ ` / 0 0 / o of 0 \ O O / oo \ O / O \ ■■ O / / O \ ° / / O ° \ / ° / O ° 0 o \ \ / / o O PCs o \ \ \O o\ �IIII \ \ ° ° o O I/\/� O �J 0 �� \ \ / ° ol '\ j \ lI APPROXIMATE DC SILT FENCE 3.05 ® INLET PROTEMON 3.07 DIVERSION DIKE 3.09 SEGIMENTTRFP 3.13 SEDIMENTRASIN 3.30 ON=PROTEMON 3.18 TE.M. SEEDING 3.31 PERMANENT SEEDING 3.32 MULCHING 3.35 TREE PROTECTION FENCE 3.38 DUST CONTROL 3.39 \ \\ o ° \ -\ - - ` \ '^ / oN \ /1 \ i l I LOCATION F�DERALI I �' `\\ / // \ ° °" I \ I I / II DAM REAK I I I BM DIANKET EPER TxaNJ:L!AnO 3.36 ° T' AREAS EEwrtx-N3Rm TO BE I O \\ ° o \\\ \\ / ° o I T I l 1 INNUNDATIOiv AREA I O j O ° \ L\ , / / \ 1 1 I 1 1 /I I/ "VIRGIN J / p / o ° '° ° / o 0 / - ° O / o 0 0 0 / r / 0 0 / 0 ° / o O o o o O o O 0 0 - O �\ * o O ■ ■■ 0 ° 0 O o \\II\i//// 1 \\ Q\ ° I I/I 1 r 1/ 11 I I I 0 SF r\l' -- SPECIFICATION NUMBER _r . ° \ 1 1 o I�/\\\\� I \ I \ \ 1 SHEETC3.9� sO To I o \ 1 o \ �\ \ \ \ ■—' \ / ° ° '= _ fl �1111 Ill /f�� °o \\ 1 I / 'o II \ `\ / ° e _ / „ i I III//_L o \ 1 / / / o /IIIIII '�\ \ 0 ° 1 0 0 o \ 1 0 / �C ° 0 \`t\ // 0 / \ o / o I \ / o / °° I / / �\ 0 MATCHLINE SHEET C3.10 I ° \ \° \� \O `\ \ ' 00 \ \ 10 \ \�\ O ` o\ \ \ \ \ SHEE.10 ♦ \ ` \ `\ \ \ 0 0/ 00 / \ ° ° �` \\ \\ ° ° /6�/ ° o \ \ \ \ ° / / 1 � SHEET C3.7H, N z 0 H DATE 0210712022 DRAWN BY VAN NIEK DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE 1"=20' Lij ``T_ vJ _ 1^Jr' z z < O w U ^Q LL Q LL Z O o LL] � L 0 O ww 06 O O w JOB NO. 46883 SHEET NO. C3.9 L ° MATCHLINE SHEET C3.9 O 0 r 0 0 O 0 0 0 r 0 0 O O O ° r ° SOIL TYPE: 28C3 ° SOIL TYPE: 16 0 ° r 0 0 o ° 0 ° r 0 0 0 ° O ° O ° r O O O ° O G r 0 o � O r 0 O O O ° r ° O ° O ° r 0 0 0 - o 0 O O O I O O O 0 O ° O o ° O ° r 0 0 ° 0 O ° O O 0 0 0 0 0 ° 0 O 0 0 0 r o o ° O ° O ° r 0 0 o ° 0 0 1 ° ° O ° o ° 0 ° 0 O o ° 0 ° O ° O ° O ° O ° O ° O ° 0 0 o ° 0 0 0 0 o ° 0 ° 0 0 o ° ° ° ' o ° o ° 0 \000,00 0 ° o ' ° o O O O p ° O O 0 O O O 0 p 0 0 0 0 0 0 O O O 0 0 O O O O O 0 O O O 0 O O O o O 0 O O O O 0 0 O 0 0 O O O O O O o 0 O O p O O o p O p O O O 0 O 0 0 0 O 0 O 0 O 0 O 0 ° 0 0 0 0 0 O O O O O O 0 0 0 0 0 ° 0 0 0 ° o ° O ° o ° ° ° 0 ° o 0 0 ° o ° o ° ° 0 0 0 0 0 0 O 0 0 0 0 0 O j °° KKK, 1 o f i-\ °° \° °°\ ° o ZONE AE ° \\�Ilk o \ \ \ - � \\°o \ \ \ \°o ° \ o 0 0 \\\\ �O \ \\ 0I�0 °1\ O p o \ \Ifp0\ \o oO It co =w p\ I w °°\ a w °\ ° 1n o ' TM 61-168 &169 00\ I I I ° CITY OF CHARLOTTESVILLE0-0 °o \ / ° DB. 4622 PG. 523 00 \\ \\ ', °° \\ / o0p \\ \\ \ \ \ O \\ \1 I oN 00 \\\ \00 ItEDGE CREEK p ° ° oo°° ° FLOODWAY 0 Op ° I 1 / / / I I 1 I l l 0 0 \\ `\ / \\ ° \\ /0 \\ \\ / \ °/ ° \\ / o \ i / 0 0— / / / / / / / / / / 0 \ / / ° °r o > / / // o o■ / "/ / / / ,-f• / / / / / o / �/ / ° / \ ° / // o 0 CONTRACTOR TO LIMIT THE AMOUNT OF o DISTURBANCE TO THE EXTENT /// lI /l l l° TM 61-170 / 0 NECESSARY FOR SANITARY SEWER / l l l CHARLOTTESVILLE CONSTRUCTION. RESTORE GRADE, o / / / o 0 SEED AND STRAW. o / l/ l ° ° WALDORF SCHOOL INC. / / ° ° // / / / o o DB. 4202 PG. 453 ' ° ° ,/ ,// ,/ // / o o 0 USE. ELEMENTARY SCHOOL ° / o ' o o / / / / o o o cbl7 / ' 0 O / o 0 / / / ° ° ° / / / ° o 0 / ° ° // / / o ' 0 SCALE V=20' o O / / / / O / // / / 0 ° ° ° 0 20' 40' ° 0 0 o p O / ° ' o EROSION CONTROL LEGEND O / O 0 LIMITS OF O \ 0 i ..... DRAINAGE DWIDE AND GRADING O / O ° / � I � 90I1- AREA DIVIDE - O / / O / O ° / CE [ONSTRUCFION ENTRANCE 3.02 0 / 0 O / SF SILT EErvcE 3.05 o / �/ ` o O / o / / / O O / IP INLET PR..N 3.07 O / / / O p / DD DIVERSION DIKE 3.09 O O p / M O / / / ° O / / ST $EDIMENTTP 3.13 ly O Op O Sp SEDIMENT RASIN 3.30 / O ° / / / \ ` ° Ou PROIErnON 3.18 / ° p p TS TEMPO. SEEDING 3.31 / 0 / / ° ° / / p / I / O `\ ° PERMANENT SEEDING 3.32 / ° // ° \ ° 0 0 / muLcxlxG 3.35 / / ° / MU 19 / O / I / 0 / 0 / /\ � TP TpTREE PROTECTION FENCE 3.38 / O / / / O \ / O / 0 O \ / O DC oust coxmoL 3.39 0 AREAS R THAN 3�I TO BE ° O \ BM SfAB11RENITH STABILISATION 3.36 O \ BLANKET / O O O / O / / O ' / \ .°VI0.GIHU EROSION ANDSEDIMEHi CONTROL xANDBODM SPECIFICATION NUMBER O / / 0 r / ° \ / \i _ SHEET C3.4 / o o � o \\ SH - / 00 / / o / \ a i'C / 0 / ° SHEET C3.9 / ° / =1 1iit 0 II L / 00 o / o /// III SHEET,Jiili �I'Ic \ , i SHEET,C3.6 — / 0 / / o / 0 /o o l o SHEET�.10 \ \ Ilp l,�lllll,,f/f,IIII\�\/%i,� \\I 00 II // `0 0 0� o\\. \Illy I /)1'folioo \ \� lam///� - \ \\� o / / / // o I/ o i 0 ° / / p 0 / / / / 0 0 0 0 /p/ /° /o I SHEETS = _;\ SHEETi C3 8/ 00 / / 0 \\° LMAP ° / o . /ew.SC. � U CRAIG W. J. Y.OTARSK1 Lic. No. 0402018507 .�, 02-07-22, m E 0 o 0% u N N "CZ >E W E W 0 3 ¢ LL t0 0 LL -' O OL h ¢a � U m O 7 p N L7 W ry 7 X of w U oQ =v S v ry = V > N ~ c Ln 0 m N � M a� W J am O cc f f Fmm w Q DATE 0210712022 DRAWN BY R. VAN NIEKERN DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE 1"=20' zw u L OG w ED � a LL Ou ° 1� 0 U JOB NO. 46883 SHEET NO. C3.10 L ----------_____ SCALEI"=20' SHEET C3.111 � SHEETC3.12 EROSION CONTROL LEGEND - -- . . LIMITS OF CLEARING AND GRADINGFM _ --� ..... DRAINAGE DIVIDEVX7;, o- L ry_0, 2- 0' 4/0/ 'SOIL 5564A2Z0N —_f --\- — SO/IL_ A R, E A DIVIDECURB SHEET C3.17 CONSTRUCTION Exl'R -nrv/c-E IIIIIII3 .o-//z 3.05 E.-EO, _ -/ -/' ••~• •.+ U_uwr •Nff); Uo 11 �M�oI3�i3A 0l2,04 8(/_�� 5.) >,0 ' 7 JONN/ 1 ----- - - - - -- -- INLn PRCTErnoN 3.07 02-0--22 EET C3SHEET C3.1 - - - - - - - - - - - $D CUI mvasox DIKE 3.09 -- - - - - - SHEET .18 SEDIMENITRAP 3.13B9®NAL IVV.1 ____-- � INVOU SD CURB W/M-e seolmENrBASIN 3.1a E- - _ - - - T0' "M� CP OUr1ET PROTECTION CTION 3.10OU¢ oIN)' 'P >EINVIN--422.80'13 _SQINLETW/GRATE SHEE 3HEET C3.1 - /, IEMORARVSEEDING 3.31 _/ INV. OUT=422.98' 15'RCf- - SD CUR INLET W/MHD wUPERMANENT SEEDING 3.32PERM.DR,TOP=2F8.72' ¢ 7 EASEMENT S O o C"D"'"G 5 WDOSEE VDOT PLAN 1dV OUT=420.72'15"RCP ,LIMITED/ J MwEXCEPTIOW13 ACCESS TEE PRORIDN FENCE 3.39KEYMAP � >ON 0-MTM— W0- EASEMENT UB Dun CONTROL 3.39E Q w AREAS s-AN B:RTD3.36 c IANETCDWInn srAwuunOry = NBIAN,.. / VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK' SPIRMICATION NUMBER Illw PAVED WALK - �\ - - - - - - - - --------/---- - - - - -- �L�REDEND SE �INVIN-435.j wPERM. DRAIN / o EASEMENT -- ----- - - - - -- SEEVDOT\PLAN- - - - - - op PROPOSED TEMP. ------------------m SLOPE EASEMENT D ATE SEE IDOTPLAN02/07/2 0 2 Nao2 - - - - - - - - ODRAWN BY R. VAN NIEKE /R CENTE'RLWE JKTRAIL �EE�DO�PLAN \ \ DESIGNED BY wPERM. PA J. DENKOw Vf_� I\ LIMITS OF DISTURBANCE=18.44 AC ME - wPS' CHECKED BY� GKOTARSKI SAN SCALE --— — —— 20' IP PERM.f EASEMEN CL Ps �S )F -- -- NSANSAN SQNSAN NO Lu L IC\ ABEMAR EC0UNT\YGIS\ ---- -ALBEMARLE COUNTGIS OITICAL SLOP�S - ANAGED CRMCAL SLOPES - PPkSERVED PS QLd Lu ai Q SF co Z � 410, wSAN SAN -rtW/ / A Wfill� Z CA ) Lm JOB NO. 46883 1♦ 'It S 1♦ ' It / It It It It /� It I It 1♦ /� 1♦ 1♦ �1 SHEET N0. MATCHLINE SHEET C3.13 1 I , C3.11 a EL a m re 0 0 0 s 3 a a 0 o cD ncD �N 00 a 02 c m c� m h a0 0 w (� Z .� ZN 0 d 2 a F m `0� o a m m B, Y N X C m o -Z 2 E o � a c 2c '0 m 0 m o � U C n O c 0 m O.E h w �E L SCALE 1"=20' SHEET C3. f l " SHEET C3.12 EROSION CONTROL LEGEND [) - . LIMITS OF CLEARING AND GRADINGPill l• l• .m DRAINAGE DIVIDE iu 0 20' 40' SHEET C3.17 - - - - - SOIL AREA DIVIDE -Al I FL� �• (`E CC"", , ENMA... 3.023.os . J. KOTARSKI 0402048507EET C3.1 SHEET C3.14x PRornoN 3.0> 0�-22JDIWR51ONDIKE 3.09NAL SHEET C .18 \ \ I ST SEDLMEMTRAP 3.13 SD FLARED END SECTION OUT ET=428.45' L L — \\ \ �j SB eDImEN N sIN 3.aa M 11 ALBEMARLE COUNTY GIS — — — — — — — \\\ \ _� / —® O N c / OP OUrLEr PROITCOON 3.19 N - - - 1 CRITICAL SLOPES -MANAGED JpyN WARNER - \ SHEE Ct3.1=-- HEET C3.16 % ; Op w 3.31 E 1 \ \\ INV.OUT=4 ~. �- TJ MPOR RV SEEDING PKWY `\ \ ----___ O W 3 / \ \\ / 1 1 I --_- PS PERMANENT SEEDING 3.32 Q U. O 3 MULCHING 3.35 � W L M / EX URB 1----\\\ ' — — -- I IdJUI� o \\\ \ , —� TREE PROIERIDN FENCE 3.39 ; O Ol KEY MAP TP M— wi N Lu GO cl;U \\ \\` \ \ \ _ _� _ - / ' / / IP DC DUST COMOL 3.39 O r u H-------�—------- \ �` / - ---- �� JV)LQi \ \ W \ T W/ 3 36 \ , _ _ a / SD CURB INL sf" NNET wnn srnwiiinnon a c _ ----- - - - -\`------- - - - - -------------- - - -- --' — — — _ _ O - __-''--- -`— — — — TOP-447.65'E BM ewNKT �V j� cf)EASE_MEN7- ---- ------ - _ _ _ — — --- -s- - --- - \\ M x a -w BEE VDO PLAN �� — — — — — — — — _ _ _ _ _ - _ _ _ - _ _ _ _ _ - - \ �� INV. IN S=442.05' 15"R "VIRG[NIA EROSION AND SEGMENT CONTROL HANDBOOK" SP'AFlfAT10H NUMBER ~ Ill to ---- — — — — \\� foss- - - - - - - - -- - - - - - ------------- - - - - -- -- - __-- -- - _ -''Y --- \\ \\�\• \� IP INVINO=433.70'15" NN w Z-�' — — — --- - _-�-- \ -- o W--------- -- __--- __ _I— -' a \ �\ T INVOUT=433.65'15"RCP �M IP Q p / -- 0 6" MAPLE \ \ \\ \ \ , \\ -- ---- ----- ----- -- — -- __ _ _ _ — — — — _ — — — _ _ — _ — _ — _ _ • \ \ \ /� \\\ I \ SF-- 3D INLE ----TE _ ------ __--- ----- _ =-- I I ' ' ' - / / / ' --- = J - • PERM. / - _ '---- Lu polumm EASEM�Ni T V.OUJa4 5"RCP _ ------------- __-- \ \ \ \ \ \ Lu > It / EAS NT i / \ \ \\ \ l O i \ VDO P-LAA( / ITS OF DISTU = 18.44 AC I \ \\ \\ P 1 \\ DATE 0210712022 IP \ \ \ \ \ '` \\ r DRAWN BY p56/ \ \ \ \ \ R. VAN NIEKER i ' p�W — ' _ — — — — — — — — — - \ `i \ \\ \\ \\ \ \\ DESIGNED BY J. DENKO \ CHECKED BY SD CURB INLET W/MHD - - 'v`c -co ;\ \ \ \ \\ \\ , TOP=454.27' • C. KOTARSKI INV. IN=449.87'15"RCP r• _ - ' - ' I v I _ - _ - - _ _ - - \ \ \ \ \ \\ \� I INV.OUT=449.84' 15"RCP + I / — ' _ — ' _ _ — _ — _ _ _ _ _ \ \ \ \ \ \ ,' • • SCALE I�� >�rr=� ���r����������G�� ���� j �_ �� ���LL�����>r�t���=� ���=�s�����J'i������� I I — _\V/_ \\\\ \ . \ \T1 ,' • 1"=20' N I I \ \ 1 pD '� omo rn w 1 PS 1 / 1 1 \ Ld II I I \ O Lu U IP , I,ED _ EV EV EV EV I / p I Ili j II II I \ / / / LL W AZ OU w I \ / I 'v Tv 'v v1'� SF II II I I I\ / / „x I \ W ■ _ PS — go ■ • ~ 3 I /\ I/ I / I � O �I I � I \ I , c I i PER7M RAHN-- , JOB NO. / � 46883 NJm m m mS m — l- 5 . E! .. ' ' ' )♦ ' ' ' ' ' ' ' '�'' ' ' ' ' ' 1 )♦ S S S S S )♦ )♦ )♦ )♦ SHEET NO. --_ MATCHLI E SEE SHEET C3.14 �'! C3.12 a N EL a m fe O 0 3 a D a 0 O cD ncD �z 00 a 6 2 c m r- @N a0 0 w (D W.� Z zN 0d a F @ `o= o a 2 Y � N X C 0.0 -Z 2 2 c c E m 0 @ 06 a c 2c '0 a 0 m o @ U M. C m O c � O.E h w �E L EROSION CONTROL LEGEND SHEET C3.11 - SHEET C3.12Li LIMITS OF CLFARING AND GRADING I T/-DRAINAGE DIVIDE - / SOIL ARFA DIVIDE 1 SHEET C3.17 ' I \ ' /coNsmucnoxENTaAxcE 3.Dz�I , / / / / . , 1 1 � / 1 ■ a� �' � o I $p nrrerva 3.05 \ I I / ' 1 / ' 1 CRAIG W. I. Y.OTARSKI 9 / 1 1 Lic. No. Oa02048507 IIP INLETPROTECNON 3.OJ\ 02-0-7 —22 SHEET C3.13 DD DTVB-IONmKE 3.09 I / / / 1 / / Do 464 / SSIOKTAT k�G O SHEETC .18 d / , %���r�_�rr / 1/ / D \� 1 1 ST SEDIMENT TVP 3.13 `9'' I , / , / / ! / / / .- - '� _ z IS SEDIMENTBASw 3.14 00 / U / / o E O /illm / / D / BP OUTLET PaoTErnory 3.18 / W . \ I / / N C SHEE (3.15 HEET C3.16 c temwRAar sEEDIrvG 3.31 / / �___ / / ' , ' , / / / 1 / \\ 1 ' ■ / I1J N E SF x PS PERMANENTSEEDING 3.32 1 — — MIJ MVLCNING 3.35 1 N W —� o SAN �u SAN a� i u o? z TP rF— TREE PROTEMON FENCE 3.38 / / KEY MAP / / / / / / / , \ \ d o N ,PERM. BARK O / / / z� Dx DC DUST caNTROL 3.39 /EASEMENT / / / � / , 1 � � / ■ 3ov)x � / / / / / / 1 / ■ �i v� o ARFAS STEEPER TXAN 3:l TO BE 3.36 ' / / / /' / / / / / ' ' , / ' / / Q v BM srABUIZEDWITHSTABIuzATIOry ' / / / / / / , / / / f = ry Z BuxKET / / EE�� ,,nj M .�. �/ >� 0 VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK" SPECIFICATION NUMBER I / / / / , K ! / I; \ / •�•�' / ~ C � (n N D Lu SCALE 1 "=20' *0 DID IP to D IP z 0 0 M > w W Q W 2 I LIMITS OF DISTURBANCE 18.44 AC t \ Z I / i /' / — W j DATE I , 1 I I Z, / / w 0210712022 ! 1 / l l 11 I I I I I ! l l I O \ 1 \.: I '? 0 !l I PS I 1% I 1 \ \ 1 1 .�,� - _ / / = r DRAWN BY 1 ! I \ \ 1 / / ' Q R. VAN NIEKER I I I I It t • I 1 \ \ 1 � ` � / / ' � DESIGNED BY /I I I I I I I I I I / I I I I, -. I \\ \ \ \ w ` \ _ 1 1 / / ,' / • J. DENKO I / 1 1 I I /I I I I I I / ! I I 'h: 1 ` 1 / / / / - / • CHECKED BY / I I I 1 1 I 1 / I I V) I `- \ 1 1 / 1: -- / / • C. KOTARSKI Z .-. • • SCALE I � I I i I I I I \ \ i I 1 1 1 , � 1 "..� \ / `: / ✓ -- �,-:"• 1" = 20' 03 v v IP , 1 I _ v ■ 0 ow 1----- - - -- -- - N / ` -- _-__ 1 1 w U 1 I //\ \\ I \� - - - ` \ \ _ 1 1 IP Z — — _ — _ _ > \ S \ - _ _ 1------- -- - --- -\ O W U ------- - - - - -- IP — — _ — — _ _ _ \ `\ Z U) - \ \ e °. \+ \ \ - �------- - - - - ---- - - - - -- 4. IP W \\ \ \ 450- \ / ' / \ \\ JOB NO. \ + \ \\ - a e a m re 0 m 0 s 3 a a 0 0 cD acD �N N 0 a0 o 2 c m c� mN D_0 O w III m 0 w a �x �v �O L ` O a m m 2 Y 0. X C N O ,L.. 2 O 0 E 0 m 06 a c 2c !0 a 0 h 0 M. M U C m 0 c 0 m 5E h w E L \ 1 - - - - - - - - / _ I MATCHLINE SHEET C3.12 / .1 SHEET C3.17 f. . ____—__ ri;____ ._ _____--- —� I \ SHEETC .18 : - f rIP 31p , SA _ ' ' -SAN �fSAN 1 S/ N SAN s IP /------------- - / \ •� I , / I \ A3 A3 19 n3 A3 I _ . Oro 90 -1 s x N■ ---- -- IP In r -------------------- SF yIn SH T C3.1— 1 SHE T C3.12 J ���p.LTH OFL ,. I (44 CRAIGW. 7. KOTARSKI Lic. No. 0402048507 02-0-7-22� 4 71CH FFT , 9d_ -I !, �I I ■I.111111111 — ... III ■■ :.. 3.15 16Lu —/ I•: KEY MAP > ul EROSION CONTROL LEGEND z H rJ NNNNNN� LIMITS OF CLEARING AND GRADING rt R O )( . . . . — DRAINAGE DIVIDE �u•u�u�u� SOIL AREA DIVIDE = N Z CE O ONSTaurnory EN R NCE 3.02 v = U Q O ~ Lu SF SILT FENCE 3.05 N N w � M Ip B. P0.01ECDON 3.07 � J O W � H DD DIVERSION DIKE 3.09 ST SEOIMEMTMP 3.13 SB SEDIMENT BASIN 3.14 OP OUFIfT PROTERION 3.18 = w TS TEMPDRARY SEEDING 3.31 W W ps PERMANENT SEEDING 3.32 V Q Q MULCNDIG 3.35 O X Tp�TREE OTE OH FENCE 3.38 GDATE LL 0210712022 0 DRAWN BY DC Dusr C.— 3.39 O r R. VAN NIEKER BM AREAS STEEPER THAN 1. TO BE 3.36 STABILIZED WITH ETABNunoN BLANKET DESIGNED "VIRGMG EROSION AND SEDIMENTCONTROL HANDBOOK' SPECIFICATION NUMBER • J. DENKO SCALE 1"=20' • CHECKED BY • 0 20, 40' C. KOTARSKI • • SCALE • 1"=20' • • FT • �� amO 2� LIMITS OF DISTURBANCE = 18.44 AC IN W \ I = 1 1 1 IP I d ■ 1 \\ o J r I Qo r` 1 z SF > w� 1 1 \ \ 1 I z Z \ ` _ _ \ \ I P IP \_ \ I I --I Q Q WIN. W no go Lu IP - - 1v. v v I I �\ I � � W U) \ • I VJ O 0� \ 1 IP CE IP r Z — — — ----- - 0 1 CONCRETE WASHO�IT \ I III \ IP 70B NO. -- ■ SHEET NO. \ MATCH INE SHEET C3.1 \ \ C3.14 I \ \ \ \ c a c e a m f� 0 N 0 3 a a 0 ocD acD �N 0 Z a0 o 2 c m r- E � c„ a0 O w Z "1 ome a w F m �o a m m .Z Y N X C 0.0 .L.. O 2 C c E m 0 m 06 a c 2c '0 a �o M U M M. c m o c 0 m 5E h w E L MATC ILH NESHEET .13 448 _ — 446 m �mm\tr-"7YIE / OFF, 444 442 / \ \ \ ------------------ ---- --____ ---- a Q CRArc W 1. K0TARSKI a Lic. No. 0102048507 � 440 \ ` \ ` a3s,�02-0�-22e 0 LIMITS OF DISTURBANCE = 18.44 AC \ \ ` " " ' ' i 434 \ 432 ` ME \ N --- ------------------- \� \ \ — — ------ '�\ \ \ 430.\/ N6 > LE SF v s uj -- HW , 3 TM 61-170 — � \ 424 o� �� \ \` � , \ \, 422 w�—Ill O CHARLOTTESVILLE WALDORF SCHOOL INC.- -� — \— — — — — — — _ _ _ \__ _ _ ' - " " " ` i a > o N 0- — — \ \ ` Ul N d. d Mr DB. 4202 PG. 453 --_ -__---------___ - - L,W u \ \ ^ _ _i / / 3 0 If) Un USE: ELEMENTARY SCHOOL \---------- - _----------- - - �� o _ \�� _ _-- \ 418 Lu Ln O 42p16 4?2 q2q I w w 478 7- DATE W � / / W\ ' ' ' ' r DRAWN BY Z R. VAN NIEKER / / / / / / DESIGNED BY \ / L _ J. DENKO ---- / \ �� // ------ — _ / ' • CHECKED BY C. KOTARSKI TII� 6 -=� • �OM—M-- OlVS LILC ' - • SCALE 1"=20' __------- ____---- D-B:5085P-G.669 N • USE.,RESIDENT-[ALco , - - - - - - • \ ---- --- \ w 2 — — i � C) N Lu � � 2 ' \ d / ■ J i Q i i i z-i J Z Lu ALBEMARLE COUNTY GIS CRITICAL SLOPES - PRESERVED O m U 1 a LL z O w — i EROSION CONTROL LEGEND i LIMITS OF CLEARING AND GRADING U I 1 . . . . . DRAINAGE DIVIDE - n_u_uiiuSOIL AREA DIVIDE - CE CONSTRUCTION ENTRANCE 3.02 06 / SHEET SHEET C3.12 SF EILT FENCE 3.05 O 3.11 Ip® — Irv1fT PROTErnary 3.0] i i� SHEET C3.17 I `� DD DIVERSION DIKE 3.09 0 \ \ I I ST SEDIMENT TRAP 3.13 Lij SCALE 1"=20' �. , SB EEWME-BASIN 3.14 0 20' 40' �_ SHEET C3.f HEET 3.14 Op OUTLET PROMMON 3.18 SHEET C3.18 \ a TS TEMPORARY SEEDING 3.31 8 PERMANENT SEEDING 3.32 ov / / —o I X—Tp— MULCHING 3.35 / SHEE C3.15 / \ HEET C3.16 TREE PROTEMON FENCE 3.38 — %�i 70B NO. 8DUSTCONTROL 3.39 46883 Q BM= 91ANKET nTXAN AREASEEPERTILLID3.36 nAKKET wnHnABluunON SHEET NO. 2Q "VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK' SPECIFICATION NUMBER C3.15 KEY MAP c 5 a U C 0 e a m f� 0 0 3 a D a 0 o cD n0 �N 0 Z a0 o 2 C aN -6 C d mN a� O w Li F Z $ Z m 0 d a 2 w O L o C a 0 m 2 Y � N X 0 0.0 2 z 0 E m 8 m 06 a � 2c 0 a 0 o M. M U m C h 0 C O N 5E Ny E F- 146883-Wetsel_Property\DWG\Sheet\CD\46883-103-C3.4-EROS2.dv✓g I Plotted on 2/7/2022 11:06 AM I by Jessica Danko MATCHLINE SHEET C3.15 // / / / // // / ■ // 1 1 � /l / r-Pin r / /firin n T 414 416 ' / ^ / _ 418 `�/ / r I / 420 / Cl)C�31 dH0 �dHO `432 / �dHO dHO �dHO Cl) 1 / O NV VS NVS \ C) n \ \ 1 T1 II \ 1 A n - - Cn / 1 / r \ ` W W -0 ' -4 1 0 1 Cz 1 — oCo 0 1 w lDO w // w 1 � (n ,� p0 m z m rr n w � A NEW. IN Ifi m = � 1 rr m y � 1" A = 1 m �m 10 w 1 N 1 1 I TIMMONS GROUP m � o RI O POINT 54 Z CO o COUNTY OF ALBEMARLE, VA M 0 w EROSION & SEDIMENT CONTROL - PHASE 2 THIS DRAWING PREPARED AT THE • • •• YOUR VISION ACHIEVED THROUGH OURS. CHARLOTTESVILLE OFFICE • • 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 TEL 434.295.5624 FAX 434.295.8317 www.timmons.com A 0 DATE REVISION DESCRIPTION >\ m � NZ �p a II N V n m m Z Z N i O m 70 O < ON m � A N These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express wdtten consent of TIMMONS GROUP. S:\103\46883-Wetsel_Property\DWG\Sheet\CD\46883-103-C3.4-EROS2.dwg I Plotted on 2/7/2022 11:07 AM I by Jessica Danko / IN \ \ \ \ \ 0 0 00 \ \ \� oo° o \ \ o0 0 \ \ 0 0 ° ° O \ / \ \ \ o p o o \ \ \ \ ° O O °\p\ p o ° ° 0 \ \ 0 0 0 \ \ 0 60 °° 0 0 0 o p o 0 0°° \ \ o \ �o 0 0 0 0 0 0 0°°° 0 0 0 \ \° \ \ i o ° \ �0 0 00 0o o ° o ° � o ° °0°0 / o ° 0 0 ° 0 / 0 o ° 0 0 0 / . 0 o ° p o ° ° / o ° o ° o ° o ° / o ° o ° / 0 -�NVS NVS D n x r z m ° U) rxrl o IT O � o 0 w ° / 0 i O O / / O O O / O O O / O p O _ L O O 0 O 0 O ° � 0 / 0 0 / O o / o / 00 / O / o / 0 o / / / / / o 00 / / / �°000°°00 00 o ° 0 0°� ° o 0 \ \\ o \ / / o° �� \ 00 j 0 \\ /j0 �/ \\ o 0 0 o 0 0 ° 0 0 o \ 0 f 0 0 p 00 O ° O ° O p \ \ \ O \ O'6�° ° O 0 ° O 0 / 0\v\/ ° / ° ° 01 \ / n /o . o / i / o / p°///// / to° \ /O9 4 / p, 1 I I too—fol \ /o / ////,//°V o / \ / o / / ° 0 °°° too In / \ 0 / /0 / \ �+ 0 0 / , o / / o 0 0= o 0 0 0 0 0 0 0 0\ 0 0 / o I I I I I \ / ° \lit / o o \O , 110 / \ / / 0 ` \ \ \ �� I \ \ \ \ \\\ \ \ 1 �Qi \\ 0 �i1 \ _4 � o ° d o °ido o 0, 0' o I— /11... -- --— —— — — — — —\\ — — — — — — — \� \\ \ \ I I WIC) Z 01(� \ 1 1 1 I I 1 I I I I \ I / // cn / cn ---- �`\ `. �\� \� I ITZ0�lZ \\ \ T II I II II II I II I 1\I I / mam/ / /���, _ \ cnm � T ' m m / �� I � --Icf) \ I I I // mm�/ of 0 or Uo-<z� nri amok \ �� >\ \ \�X �� !\ mix — — — —— CnI zm� � \ \ 1 I 1 I rum \ \ `\ \ \ \� \ I Z'1�X \ \ I I I I I I �7 \ m rn I I I I Il I / T. In cn cn n'1 m a:2 a:\ \ \ \\ x Z \ I \\ \ IT �� w w w \ \ \ \ I I I \ C/)� )i hn s \ to c � m l ,m ' m - I I I o I I I I I I I\ \ \ \ \ \ Z m m m Cn I I \ \ \ \ \ \ 1 kk ' n • LA i ro - - m o0 z mrr IN < A r o_ w ru n it m m Z ro ` \ I\ \ (n ♦ gm o o O MATCHLINE SHEET C3.11 n THIS DRAWING PREPARED AT THE CO CHARLOTTESVILLE OFFICE • TIMMONS ROUP• •• YOUR VISION ACHIEVED THROUGH OURS. O t" 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 �� 0� ✓t TEL 434.295.5624 FAX 434.295.8317 www.timmons.com ti Nz Z I o _ o R I O P O I N T N m m A v O DATE REVISION DESCRIPTION N O O r CO z COUNTY OF ALBEMARLE VA I' m z z 1+t�� ►a z CO o N m 70 70 o z o ru m O m VIt� V w EROSION & SEDIMENT CONTROL - PHASE 2 These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express wdtten consent of TIMMONS GROUP. MATCHLINE SHEET C3.17 m ° 0 0 0 0 O ° O ° O ° O ° o ° O ° O ° O ° o ° o ° O O O ° O ° O ° O ° 0 ° O O O O O ° 0 ° O ° 0 ° O ° O ° O ° O ° O 0 O O 0 0 0 ° O O O 0 o ° o ° O ° O ° O O ° ° O ° O ° O ° 0 ° 0 ° O ° O ° 0 0 0 0 0 ° o ° 0 ° O ° O O O ° O ° o ° O ° o ° O ° O ° 0 ° 0 0 0 ° O ° O ° O ° O ° 0 0 0 0 ° o O ° o ° o ° VOOOO O ° O ° ° ° 0 ° o ° O ° O ° O ° O ° O ° O ° O ° o ° O ° 0 0 0 0 O ° O ° 0 0 O o O O O o O O O 0 0 O 0 0 0 0 O 0 0 0 0 0 0 O O O o O 0 0 0 O O 0 O O O O O 0 O 0 O ° ° O 0 O O O O 0 0 0 0 0 ° o 0 0 0 0 0 0 0 0 ° O o O o O 0 O ° O 0 O 0 O 0 0 0 0 0 0 ° O 0 ° 0 0 O O o O ° O O 0 O n SF / I ° '� �V \ o ° \\ I I I O \ \0 0 i 0 \ \0 ,\° I \ 1 I I I I I l l \ o o O \ \ \o ° 0 \ \ \o ` 0 I I 1 ZONEAE - - ` \ °O \\ \\ \\°° \ \ o \ \ o ° \ 0 \ \ °° o o\ \\ \ 1\00 1 0 \I \\ / / 1 / 1 1 1 I / If \ \ 1 ° 0 ° \ \ \�II °o\ / 0 \\ o° oo TM 61-168 &169 °° ' =CITY OF CHARLOTTESVILLE ° 1 ° °\�/ °\o wDB. 4622 PG. 523 O / / o /0 0 /0 60 0 1 If 0 If °O \ \\ \ \ \ \ \ /mil 0°\\ \o \ 0 /IQ °\Cl ° \ °\ o 0EDGE CREEK 0 ° p 0\\° I0o oo ° 0FLOODWAY 0 ° / / i 0 \ \ \ °\ 0 \ \ / \ 0 \ /o off I , , 1 , , I \ I / , / // // \ \ ° I I \ l - l l If 0 \\ \ Oo/ \\ I It o� ° \ \� / \I ° / / / / 0 \ \ / ° ° \V /V l )/00 ° / ° \\ / I l 11 / ° \ ° / / ° ° 0 \ ° / I/ / O o 0 / // / o O 0 / V / o O / 0 / / / //0 0 I / O / / / / o O : 0 / / / / O O / O / / / I / / / o o O / / / / 0 0 0 / / / // o o I o / / 0 0 O / o / ° ° ! Ep17 o / / / ° ° O o / / o O o ° ° / SCALE 1 "=20' 0 / / / o O O / / ° / / 0 0 0 20' 40' o o / ° ° / O // / // / o o EROSION CONTROL LEGEND O / R� ❑MCf6 OF CIF_ARING AND GRADING " / O O / / / O O O / CE . DRAINAGE DIVIDE - / ° / n�u�ii�u� SOIL AREA DIVIDE - O coxsinurnow ENTRANCE 3.02 ° / / p ° ° SF suT FENCE 3.05 o 3. a / / IP TxLEr PRDTErnory m o o o O / // DD / / / DIVERSION DINE 3.09 O O / 0 / / / \ o o / ST SEDMENTTRAP 3.13 ° ° / \ SEDIMEM &OSIN 3.14 ° / O / OP OIIIIkf PROTECTION 3.18 --�-- __ o \ 0 \ ° / / TS TEMPORARY SEEDING 3.31 o ° ° / / O O / / PS PERMANENT SEEDING 3.32 0 ° / ° O / \ / MD MULCHING 3.35 O O / o TREE PROTECTION FENCE 3.3e o ° 0 O / O / / DC DUET CONTROL 3.39 / O / .0 / \ ° / ° / / ° / - — - AREAS STEEPER THAN 3:1 TO BE 3.36 O I / O \ / O ` / oM STAB LIxED WITH s Bluunox \ BLANKET ° \ \ •"VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK' SPECIFICATION NUMBER ° / / o //vh\ \ \ SHEET C3.11 `�" — SHEET C3.12 o \ o SHEETC3.17 / ° ^ / o o / 1 /l /� \ / 0 �/ <1 SHEET C3.13 HEET�3.140 / / O / ° 1 / SHEET C3.18 d 0 / ° 1 / / ° I O / ° / % O 1 / O / '*V— 0 1/ / 0/ SHE�7 C3.15 HEET C3.16 °0 I 0 o ° i a ° °/ ° \ 0 0 0° / ^ \ ° \ KEY MAP 6 ���T7� oFL.'i 4 , J G U CRAIG W. J. K0TARSKT Lic. No. 0402018507 .�, 02-07-22, t7 N z 0 m I DATE 0210712022 DRAWN BY VAN NIEK DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE 1"=20' \ 1—i zc L o pwU a Z D}L0 5w L u 1�1 Z 0 Q O W 06 O ON 0. Lu JOB NO. 46883 SHEET NO. C3.18 L F- S:\103\46883-Wetsel_Property\DWG\Sheet\CD\46883-103-C4.0-LAYO.dwg I Plotted on 2/7/2022 11:08 AM I by Jessica Danko 0 0 0 o J 0 ° ° o ° ° \ ° o ° 00 °° / \ ° ° 0 0 0 0 \ ° o ° o 0 \ o ° ° 0 ° o ° A ° ° o ° ° o '2 V A/ 2 \ ° 0 "° °00Oo° n I'T \ \\ / anal \ \ a rri °°o °�W1�Oo \n=mr \/ \\ \/ -I o t% pI 0 o00 o� 0\ °O0o0O00000pINS Op ° OOOOooOooo ° o o 0°/ ° ° O O° \ ° ti °O ° o 0o o o o°° ° °0 0 °° 0 0 °° ° ;1 n °°0°° ° m 0 °° ° ° ° a aa a o a a a ° 0 o/ 0 0 00 °o ° °o o 00 0 ° °o °o ° ° 00 ° a ° ° \1° / °// ° ° o \ o O 0 S /° 00 d/0 0\ 0 \ �D /lz� o/"�o go- 0 ° / 0\ b �� �\ Q o o °/ / °° ° \ \ \ ° ° o o ° o ° / /p o / 7 Q \ 0 0 o 0 \to o\� \\ \ \\ // // O'O' / 00 '6 0 0 \ / / �jdl� / �QLo 0 0 / o 0 )0 \ 00 \\ \ /\ / 10 00 \/ \ \\\ °000 I\\ \\\ ° 0 0 0 0 0 0 0 0 o 0 0 0 0 ° ��/\\ \ 9 I o ° 0 ys\\ �� b o� 0°° 0 0 0 0 0X.\P o o o o o o o o o o o o o o a`a_� I Li\ \ / '' and IT! —\ m \ I \ / I ttaAAiy -A.O0)m A \) /% ( cn \ / i Fri vo-rlO O' 00mX3 w ! d I z AP)QC.0cI' �Zm �nm I 0M cmnD0 Z I �mOO X c 1 / \ / n --I II // [ .. u....>... .r.. ':.,. f... Y. '.!-.. a.r .r ., ..'a !r'1. •4: ': ;n.t +� r..y D I I I I �mnrl rin I I \ I w rn m a N- r 1iy y "v I / I / I / / I /I / I i 0 ®� INAMM �r %✓/ s � � a0T ✓GA: e a WON - r ftj * �r��a� pru.nnnr.u.x�v �19i�r4E9Y�lao�rlllR®REOHO�� LIM .� ���i� ■■iii 111111 I: 0 or- \ TIMMONS GROUP .•-':'•. CO m o RI O POINT rn 0 Z o COUNTY OF ALBEMARLE, VA OVERALL LAYOUT PLAN ~ � m � II D Oy � Om z coO � O i 1711 tic 4i/ THIS DRAWING PREPARED AT THE YOUR VISION ACHIEVED THROUGH OURS. CHARLOTTESVILLE OFFICE 608 Preston Avenue, Suite 200 Charlottesville, VA 22903 TEL 434.295.5624 FAX 434.295.8317 www.timmons.com DATE REVISION DESCRIPTION These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express wdtten consent of TIMMONS GROUP. SEE < i JoNNER �N I� I I POSED I RETAINING WALL IALB EM RLE UI CRI CAL ES - / / SEE NOTES: 1. CONTRACTOR TO CONFIRM WATERLINE SIZE BEFORE MAKING CONNECTION. 2. CONTRACTOR SHALL VERTICALLY RELOCATE EXISTING UNDERGROUND UTILITY LINES AS REQUIRED PER GRADING PLAN ON SHEET C5.0. 3.5 FT OF COVER SHALL BE MAINTAINED OVER EXISTING WATERLINES. CURB —\— _ PERM. PARK EASEMENT PROPOSED RETAINING WALL )P=43 .00' 80'15" CR 0 BUILDING 12 TYPE D 6" GRAVITY ADA PARKING SANITARY SIGN (TYP.) SEWER LATERAL DOMESTIC LINE'B' FIRE LINEN SCALE 1 "=20' 0 20' 40' LEGEND: CONCRETE SIDEWALK LlHEAVY DUTY ASPHALT LIGHT DUTY ASPHALT HEAVY DUTY CONCRETE CONSERVATION AREA MILL & OVERLAY Sy GuRBvL&TH0 TOP.41872' IN=42 .85'7 INV. T=420. 'P u INS 1:4:qx I '�• ' '�- ' —1 X ' l — .� Crt]CM; • 11 /I I / 11 �c�sl TR OF .l. -t U CRAIG W. I. KOTARSKI Y Lic. No. 0402048507 n E 0 0 M U N N C > E ° E w Luu _ 3 a o U. O K L M Q J U W Z w —in O IL V' W Z W M R H Y re' 30 x Q n J w w O_ =U>� c N n � M w � OJ J Ln Ln 0 O — — — — — — — F FLARED END SECTION o INV. IN=430.53'15"RCP w w w = Q O z I O I DATE 0210712022 0 / DRAWN BY 50' LANDSCAPE BUFFER(TYP.) / I R. VAN NIEKER / • DESIGNED BY I ' PERM. PARK I / EASEMENT J. DENKO � • / cFF VDOT PLAN • CHECKED BY I / / 19 • C. KOTARSKI SAN soSAN — SAN • • SCALE 18 1"=20' jowom ;........ i...; S%W=MlLwwwommomm ..b .7..la...� If 6" GRAVITY SANITARY j OSEWER LATERAL ' N w �r BUILDING 9 5- PROPOSED A -3 RETAINING tl TYPE D = In i POTENTIAL WALL ; Z i FUTURE i BUILDING IN DOMESTIC LINE'B' AMENITY •� FIRE LINE'A' ■ co AREA 6" FUTURE ADA PARKING 90- BEND (TYP.) ■ 9,385 SF DOMESTIC SIGN (TYP.) ; ' s AND FIRE LINE 1.5" METER r a....� i....• Z .......... VAULT Q a: Ny OWN ... ON v 6" TO 2" ' mm Z 5' REDUCER Ld (n Lij LL }}06 AND VALVE O z SAN SN SANZ D 26' 6 X 6" TEE O 7 6" TO 2" AND VALVE 8 6" X 6" TEE O \ 90o W N REDUCER 6" X 6" TEE AND VALVE W AND VALVE (TYP.) \ BEND 10, \ R10 R10' \ \ J X6 Z TEE AND VALVE• 1.5" METER VAULT FIRE LINE'A' c0� DOMESTIC LINE'B' 26' BUILDING 10 6"TO2" C) TYPE B \ \ \ _ 1.5" METEU1 REDUCER BUILDING 7 TYPE B 0G12� ' 90°BEND (TYP.) — FIRE LINE W z DOMESTIC JOB N0. LINE'B' 46883 \ \ �)��� 1♦ 1♦ \� SHEET N0. MATCHLINE SHEET C4.3 7kC4.1 TEE AND \ \ 11 11 'I �L 11 / L— c a E' T fe L VDOT IF \ )TES: CONTRACTOR SHALL VERTICALLY RELOCATE EXISTING UNDERGROUND UTILITY LINES AS REQUIRED PER LADING PLAN ON SHEET C5.0. 3.5 FT OF COVER SHALL BE MAINTAINED OVER EXISTING WATERLINES. A KNOX BOX SHALL BE REQUIRED FOR ANY STRUCTURE NOT MAINTAINED BY BY 24-HOUR STAFF. ICHITECTICONTRACTOR SHALL COORDINATE WITH THE FIRE MARSHALS OFFICE FINAL LOCATION. SD F ARED END SECTION --- l SD FI ET=428.45' �1 _�------------------------- OUTL - - - - - - - - - - - - - - - - - - - - - I 1 ALBEMARLE COUNTY GIS I 1 CRITICAL SLOPES - MANAGED l JOHN WARNER PKWY y \ ---------------------- — i PERM. PARK SD INLET W/GRATE — --- ' EASEMENT TOP=444.03' PROPOSED 50' INV. OUT=432.63'15"RCP ' LANDSCAPE BUFFER 1 v U H t w w S , w w Lu t w z J 2 , U LPERM. DRAIN EASEMENT SEE VDOT PLAN -S g SAN SAN SAN SAN � 1 L 6" GRAVITY SANITARY ' SEWER LATERAL t ' ADA PARKING ' SIGN (TYP.) BUILDING 9 TYPE D 6" GRAVITY SANITARY SEWER LATERAL .— DOMESTIC LINE'B' �— FIRE LINE W BEND (TYP.) 20 BUILDING 8 TYPE D ADA PARKING SIGN (TYP.) EX CURB C7 a SCALE 1"=20' LEGEND: 0 20' 40' CONCRETE SIDEWALK \ HEAVY DUTY ASPHALT LIGHT DUTY ASPHALT \1� HEAVY DUTY CONCRETE CONSERVATION AREA Q _ _ 2 - - - - _ MILL & OVERLAY \ \ INV F7: SHEET CI\\ Cl o 0 SHEET C°00°O0o SHEET C4.2 0 �A O Ili U CRAIG W. J. KOTARSKI — 1 Lic. No. 0402048507 �, 02-0-7 — -4.5 SHEET C4.5 1� KEY MAP SD CURB INLET W/MHD 2 _ ------ \ TOP=447.65' r INV. IN(S) =442.05'15"RCP I ' \ INV. IN(N)=433.70'15"RCP INV. OUT=433.65'15"RCP L— E I � \ I I .+ I 30'LANDSCAPE BUFFER(TYP.) PROPOSED RETAINING WALL ■ 1 1.5" METER 6" TO 2" 5' VAULT REDUCER 5' ' A 6" X 6" D VALVE I ' TEE AND 6" X 6" TEE 26' 4 VALVE AND VALVE 900 \ \ \ \ BEND ' E{iA • 6"X6., �\\\ TEE AND -�``\ �L 26' \�L/ ADA PARKING VALVE . z" ADA PARKING SIGN (TYP.) -oSIGN (TYP.) \ \ 1_5" METER VAULT i, s REDUCER 5 ' BUILDING 6 ' BUILDING 7 TYPE B 7f -I,- TYPE B - ,6 'rl90° BEND (TYP.) ' FIRE LINE'A' \ DOMESTIC LINE'B' \ \ � >•r >• i• >t >• i• i• >t >• � >t >t >t >• >• i• i• i• i• >• >• i• >• i• i• i• i• i• � i• i• i• � _(. �- i• i• MATCHLINE SEE SHEET C4.4 \ PARK AREA EXCEPTION 8; QWEST COMMUNICATIONS CORPORATION DB. 3613 PG. 352 SEE VDOT PLAN OPEN SPACE 1.1 ACRES DEDICATED FOR PUBLIC 1 USE. TO BE COORDINATED WITH ALBEMARLE COUNTY 30'LANDSCAPE BUFFER(TYP.) ����itititi•�i•ititititit it SD CURB INLET W/MHD TOP=454.27' INV. IN=449.87'15"RCP INV.0UT=449.84' 15"RCP iolzA or I / NI / I � Il I RNV T BE DEDICATED II (0.82 CRIES) II I I II EXISTING PROPERTY LINE PROPOSED PROPERTY LINE 10' CLASS A - TYPE 2 SHARED USE TH MILL & OVERLAY � i• it it it it it i• it i• i• M E 0 o N 6 N C > E 6E w Lu L, 3 LL 0 a o O K L M Q J U so Z w j —vn O �Ul NN L z H of x 3 0 U) U n w w x C N z O_ =U>Lq c N > M Lu Lu W J Ln 0 0 x C7 0 x F 0 w w L U z O 0 O Y d O DATE 0210712022 DRAWN BY VAN NIEKER DESIGNED BY J. DENKO CHECKED BY K0TARSKI SCALE 1"=20' J Q > z�w O m J LL Q Z 0� O 06 O O J JOB NO. 46883 SHEET NO. C4.2 c a c E' a fe 0 0 s 3 a a'O o ,3 aco 2N 00 a o c m -- 's0 mN a� 0 w zN od � a F m o a oc 2 Y .2 ° X c 016 0.0 m c c E S o � a c Na !0 a o m o m N 6 m ° c 0 5E h w �E L is\103k16883-Wetsel_Property\DWG\Sheet\CD\46883-103-C4.0-LAYO.dwg I Plotted on 2/7/2022 11:42 AM I by Riki van Niekerk m� z Z7 0 D 0X c Q° CO A mm r z G) .1j DD0 20 ZCn p \ MATCHLINE SEE SHEET C4.7 ` \\ �---__ __ __---- \ / I v EDE] 1111 r O 2 0 s� p r o < c c cp IT m D y IT z < z O _U vDi 0 p D Z x x D IT r D r IT n >(nJO 11 00A-zmZIT TC00Z0A� D�0oC)M r nx0p� r m < -0 0. mm U ;U 10� G)> ?mm�C)< nxzzm Irn5 0 C: Z I Immzr X p A 0 >-n r-z;u IXm�r- x ACn z<nm0 2 { --I>I Dc �m nc WCn 0� �z O zZ -nz �O 00 �y 00 Z X M =D Dz IT p m o C m IT D00 { { r ai z D U) N A x IT 0 IT ° 0 0 0 o ° A co "00 0 0 .0�0 / o \ ° I o ° ° ° ° ° ° \ 0 ° ° 0 0 0 . 0 o 0.0 0 o 0 0 1 1 1 1 1 �I x c> A NHS In NHS So NHS 00 NHS NHS on NHS no N� < Lr 1 Cl) IT o o p 1 �z0 m rn 5z0 IT 71 MD� T1 z m U 1 C)o �D� z 0 r W < -;(-7I 1 t7 D l75 W ( v 00 r � � D r �o a 1 D m Z Ln D In z D � Z 0 m <mrn Co o0 ��^' mz mN N p A rn 1 ` fm1 M z D D c W ZD Z �y V/ Dm �mX p�cc0 Gyrn IT mz n��0N mo 1 1 p 01) �Q A do o / // < a / / / /r A // / a / / / D �no A r///g m D / D m CO 1 n / a:z rn O / // / cn ap r pX W O W m A0///�c t3,m �c 1 m / r r m mm / / m� 011C/) mp 1 m O 1IT D M cn> 1 A -n U)D G7� zD Dmx / // / / /rn zA 1 1 mz/ / / / m �0 0 rn It , FICAil 17 119 J� N J(fl M IT mp 0 00 A D z zo C p U't Din IT K —1 �r — n < o» �K °°� IT C/)�l rn �m n RI� z m W D U1 MATCHLINE SEE SHEET C4.4 TIMMONS GROUP .•-':'•. Ln 01 0 M Wo W0 RIO POINT COUNTY OF ALBEMARLE, VA LAYOUT & UTILITIES PLAN 0 rrnn o J / / n NHS w O 1 / / L C z WO 1 THIS DRAWING PREPARED AT THE YOUR VISION ACHIEVED THROUGH OURS. CHARLOTTESVILLE OFFICE 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 TEL 434.295.5624 FAX 434.295.8317 www.timmons.com 1-. m V n u VOm1 vOp I D O M n M ? Z N m M N O Z m p DATE REVISION DESCRIPTION These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. F- o:n uawoaarvvecsei rruperrywvw�aneeow�noaaa-i I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 -uw.u-v+r v.uwg 1 rioui on ut/zuee -I I:ua Nm I oy Jessica uenK0 MATCHLINE SHEET Q � 4 (n 02 M p n O K m D� z IFF O�cnD K m r 90 W D --I � Z `- - r � n M t M M M M M M G) F 0 D C t7 / _/ -4 721 / D M (Z / // /�/// �o al D / / / zD OF) -Uz �D v z D n /n �C �D //J �// // / / C m0 z� / °° oo z -0 D / ono o m� /// Z D C � v � / U) m / v m D z 1 1 1 1 D 01 NVS m r _ _._._..._. m. Cil M. I I 0 1 I I ra/O �n 1 I D 711 Cn r 9 (/f LiI I 00 1 1 n m 1 r Z � 1 M A Li W; N 1 1 W w 1 N M c- — - — — o=in- - N m m n O m r j m pr c§ �omDZ >G) nrin °= �x� rn / y �77 0) C < D D < r < m 171 TI /00 / // / / / // / / / // / / / / / / / / / / Jr�} m / / / / / / /. /..L� /.ram. .L� l,.LI ./ / 1_/ ./ 1. L/ / /./ .V ..i/ 1./ ,—/._ ._.—.—. n .. I I �o 1A0) DA 4 't m a �O W W W 0 C ILI� iz — = <0G) M W O zU) n C W � y � m o, ° m o � 6-iz o m�D z� m -0z O OT O C o) moo — - —-------�i — — — — — — —------------------------- - --- W r-- o w o--------- -- — — m „ O-Ay UG)G)p `/�/////l`/� � PAP /// // // �/ / / o�n 01 J 1S6'3 --— -- ------------ J— � 0 coo 00 Oo) 1 v Q, _Im m0 -13 rn DrD �ODo -0 o 1 A m M CD �= 00 rn z Z m z o � o z z 1 x �0 �r00 M0 m m a;o Gm p Do 1 (1)-r m� 0ADn = 1 run mZz El0� III 1 rum 1 0o) 3 0 a: r x 0 m --IQO U) Z 1 c O D C m 0 1 z� D Q) m �7 z A z 1 z Z x 0) m ° 7n 0) A > y D 1 m X rr m 1 TIMMONS GROUP .•-':'•. .4 n m 0)O �1 Opp �o Wo RIO POINT COUNTY OF ALBEMARLE, VA LAYOUT & UTILITIES PLAN I MIN #' M M / 1 / Q) 1 / mzG) �< M 1 co mz 1 WG) 1v I 1 O m I m 0 D 00 C / 1 mz 00 1 CY) 1 rn 1 m D �z 1 / y , 1 1 1� x m nn /Z-/�O /,// /A 1 1 1 T 1 1 1 1 1 N ° ° 0 m I m ----_.----- A 00 A co �Y o V o \ / O ° ° ° ° ° 0 ° ° ° O ° I 0 r 0OzOOA sp 00.00000 m m � \ O G�ZO zQ'z0 { m� m m m m o - Kw+��7J?',, a r: Ij'•�I �n•inni THIS DRAWING PREPARED AT THE YOUR VISION ACHIEVED THROUGH OURS. CHARLOTTESVILLE OFFICE 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 TEL 434.295.5624 FAX 434.295.8317 www.timmons.com �Na �p Ut >\ m Z II V ° n m m z Z N i CZ)m O m 0 m < N A DATE REVISION DESCRIPTION These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express w itten consent of TIMMONS GROUP. F- S:\103\46883-Wetsel_Property\DWG\Sheet\CD\46883-103-C4.0-LAYO.dwg I Plotted on 2/7/2022 11:09 AM I by Jessica Danko F1 r- p m m r co _ A Ro r o y C: C: m � m z { Z z = U) o 0 = D D m D r m =1 / 0 71 o m 0. 711 p p 0 O o 10 to 0 9' \ MI A0 0 A 0 O p 00 O V 0 O 0 0 p 0 0 O 1 / O O p L.. O p p /J X O 'O 0 0 0 0 0 co AI _ MATCHLINE SHEET C4.8 I I I / d`' I / I '0I I I I I I / � 1 \ dS \ I \ dS I 1 / I 1 I I I / / I I I / 1 / 1 I I I I � vJ O I m 1� .W m Q) ° G) 10) III _--y /0) (�L�! C) M M TIMMONS GROUP .•-':'•. m o RI O POINT MICO o COUNTY OF ALBEMARLE, VA O (N ' LAYOUT & UTILITIES PLAN Z7 O U O U) m 0 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1� D n 1 r Z m 1U) _ m M 1� A 1" 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 THIS DRAWING PREPARED AT THE YOUR VISION ACHIEVED THROUGH OURS. CHARLOTTESVILLE OFFICE 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 TEL 434.295.5624 FAX 434.295.8317 www.timmons.com �. Ln N m CZ)W 2C ti _ n, n m O { Z o m p 2 ? po D Z j V O N m O NJ z DATE REVISION DESCRIPTION These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. PROPOSED STORMWATER MANAGEMENT ' FACILITY FHA 6 FREE STANDING GARAGES OIL 450 BEND 6" DIP WATERLINE - PROPOSED LOCATION OF INTERPARCEL VEHICULAR ROAD CONNECTION TO TMP 61-167A I � � 22.50 BEND 14 MATCHLINE SHEET C4.4 I \ \ \ 1 1 \ \ 1 I\ 1 1 \\ SAN. LAT DOUBLE TAP \ WM (TYP.) I \ \ I \ cn \ , 1 \ 1 \\ _ — \ D z 1 \\ ■ \ , 24' /n _ — BUILDING 2 D = z — — _ _ (5) TOWNHOMES \ (2 STORY SPLIT) \ 1 1 \ \ 1 • \ I / I • \ \ I 1 . \ SINGLE TAP z — _ WM (TYP.) 1 \ \ C \ 1 13 13.74' 15' SETBACK FROM�/ \ \ \ PROPOSED V \ PROPERTY LINE 2 \ BUILDING (4) TOWNHOMES (2 STORY SPLIT) \ 46 231 450 BEND . \ CONNECT TO ADJACENT DEVELOPMENT • / WATERLINE OR ADD BOV & PLUG FOR FUTURE • \ \ DEVELO • \ \ / ,'i ��/ �%�� •�'n\ ram ^ . k\\�_ % �1 i` i n ='' . _. NOTES: 1. CONTRACTOR SHALL VERTICALLY RELOCATE EXISTING UNDERGROUND UTILITY LINES AS REQUIRED PER / ` I GRADING PLAN ON SHEET C5.0. 3.5 FT OF COVER SHALL BE MAINTAINED OVER EXISTING WATERLINES. o 2. A KNOX BOX SHALL BE REQUIRED FOR ANY STRUCTURE NOT MAINTAINED BY BY 24-HOUR STAFF. ARCHITECT/CONTRACTOR SHALL COORDINATE WITH THE FIRE MARSHALS OFFICE FINAL LOCATION. S P 1• � � t t i t t t t t t t i t I a 1 � I PROPOSED 100' STORAGE & 1 00'TAPER LEFT TURN LANE I� INTO MAIN ENTRANCE IAv O MILL & OVERLAY / EXISTING PROPERTY LINE PROPOSED PROPERTY LINE DUNLORA FOREST SUBDIVISION O O o °o/ O O O O SHEET C4.8 o ° \ O o ° O 0 O ° o 0 / o 0 0 0 0/ o ° 0 O O / o .0 o ° O / O El CONCRETE SIDEWALK E:l HEAVY DUTY ASPHALT LIGHT DUTY ASPHALT HEAVY DUTY CONCRETE CONSERVATION AREA MILL & OVERLAY C4.2 SHEET C4.6 c C U CRAIG W. J. KOTARSKI Lic. No. 0402048507 .�,.02-0�-22, ui 0 0 x c7 0 x 0 w Lu x z O Ln 0 0 r w DATE 0210712022 DRAWN BY R. VAN NIEKER DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE 1"=20' z J �; z�w H� < 0 cLu c LL Q 00 LL 06 FBI z � o O J JOB NO. 46883 SHEET NO. C4.6 0 EL a m fe 0 s 3 a a 0 o cD n0 �N 0Z a0 0 c m r- �N a0 D O w it Li F Z $ m O w 2 $ F w `0 0 a ° m .Z Y N X C 0.0 2 2 Z m h � E m 06 c �a °a 0 h m.o m U n O c � 5E in N E L F- I:\103\46883-Wetsel_Property\DWG\Sheet\CD\46883-103-C4.0-LAYO.dwg I Plotted on 2/7/2022 11:10 AM I by Jessica Danko 1 � \ 1 \ 1 \ 1 \ 1 \ p O \ \ p ° O \ / \ \ \ \ O / \ 1 \ \ O \O ° ° p O O ° p p o ° o ° \ 6 0 ° o � o /o 0 0 0 0° p o 0 0° o° o �\ /o 0 0 0 0 0 000 0 \ ° 1 \✓ 0 0 o 0 o j o 1 0 0 ° 1 1 1 °° 1 1 1 1 1 O 1 ° a 1 p°' 1 ' NHS / NVS / 00000 1 � °°°°° \ / p O O \ /p O� °O am z 1 0 0f°lei O°° m ° ° '/ \ °° / \\ r1 / ° O ° \ \ 0 O ° ° n 1 s�ti /°°o / �o°°° \ A 1 oo / 00 w 00 �/ 0 0 ° / \ o° 0 0 ° ° o / 0 0 0 o O / p O O 0 \ / oo t$9� // /pop 0 O p / \ / p 0 ° p// ° 1 \ / 0 / ° / o o ° ti 10 / p �, / \110,` \ / \ y \ / oo /oo 1 d \ \ \ o 00 / \ p 0 / / ._ __ __� _ _ \ / 1 \ o 0 0 / o / - - \ —� / �� p 0 0 0 0 0 0 0 0 0 0 0 0 — — / / °�j, 1 / � V o Q) o°°o / 0 A A /' ` A\ �� 1 1 0' 1 �- ' 1 O ° � / °/ _ O ° ° 1 p 0 O ° ° ° ° p° p p o 0 1°°° 1 1 / 1 � 1 1 / 1 / 1 1� o�0G , / Ncoom / D E: n m 1 00z 1 / Amy 1 / _ / mom / �—/ 1 o0 /1 1 m / 1 1 I F 1 I 1 I 1 II 1 I 1 I 1 I 1 1 1 \ 1 1 '\ 1 '\ 1 \ 1 0 0 O O 0 0 / N o_ D m r N O / Ji 0 to 2 O ° m p, \ °OO°oo(jol°09 A 0 p bo o \ p O O O O p O \° 0 0 0 o 0 O O p O O O O // Al \ \ III \I L] I OF O w �m o 7 r- X<{ nc omm r z 0z z m o = D \ D m m i T m \ ` m m /\\ \ \ m � , y0 Q\ \ \ \ O T TIMMONS GROUP .•-':'•. Ln m �o V o W o RIO POINT COUNTY OF ALBEMARLE, VA LAYOUT & UTILITIES PLAN y 0 E SHEET C4.1 THIS DRAWING PREPARED AT THE YOUR VISION ACHIEVED THROUGH OURS. CHARLOTTESVILLE OFFICE 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 TEL 434.295.5624 FAX 434.295.8317 www.timmons.com �p a N 0 m Z II V - n m In CZ)03 O ON m < N A DATE REVISION DESCRIPTION ib CO Oc"ri' � ✓t I ° O � y 1-i I CL tQ �l t�1 Q trfT \ M� 6 I LAy ��1 NLA Ki Nan These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. F- S:\103\46883-Wetsel_Property\DWG\Sheet\CD\46883-103-C4.0-LAYO.dwg I Plotted on 2/7/2022 11:10 AM I by Jessica Danko C= a' ° O O 0 O 0 O ° 0 O ° O - O 0 O 0 O ° O 0 O 0 O 0 O 0 O 0 ° ° O 0 ° O 0 O ° ° 0 0 ° ° 0 o ° °° 0 0 ° o °° o ° o ° o ° o ° o ° ° o ° o ° °° °°° ° o ° V ° ° O ° ° ° O O ° V°° O Z ° O°° 0 0 O°°°°°°°°°°° 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ° 0 z 0 o 1-9 ° 0 1 ° o °° O 0 0 0o m o X ° ° o W 0 A 0 o ° z °°° O o 0 0 0 0 0 0 00 0 0 0 0 ° Z ° o ° ° D 0 0 0 0 c A (0 Ill ° m°°° 0 0 0 0 0 0 0 0 0 0 0 o O o o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 \ \ °In °In m ° m °°° O O O f1.10 O 10 0 9' \ n A o° A co 'o v o \ o 0 0 0 0 0 0 0 0 0 0 0 �.. 0 0 0 0 \ ° O ° 0 0 O 0.0 0 0 0 0 IN �l ei Iwo �4 1 14 •Wr� r,. f. .,; .. *4:::::d: ° o ° o o ° o ° o ° o ° o ° n o 0 0 0 00 ° \ / 0 0 o O 0 / _I 0 10 -I N n°00 m ° o ° � ° \ lJ p o °°° \\ \ /.' � y � --ate ° 0 ° ° ° ° t 11 / 0 0 0 0 ° \ / ° 0 0 N rr^^ C. \ \ 0 ono \ oo o, 0 0\ m o / � � � 0 0 o ° ° / / ' —DI \ / 2 \ \ \ \ \ \ \ ° ° ° ° o ° 0 ° ° ° ° ° ° 0 ° ° ° ° o ° / / / ' / // IT ' ° \ \ \ \ o O ° ° 0 // o \ \ \\ \ 0 0 0 \ \ \ \ 0 0 ° 0 0 O \ J. o ° ° 0 0 \ \ \ \ \\ \ \ \ 0 ° ° ° ° ° o O 0 ° ° ° ° ° 0 o ° °\ \ i \ ° ° 0 \ \ \ \ / m / / / /' o \ �10-1 o ° o ° \\ \��\. .\\ \\\ // O // / io ° ° ° ° ° \\\\ \���� \\\� \\�� /// �// / // io ° ° ° ° i o \\ ° 0 ° o \\ I \ ��\\ ��\\ ��\ // //� / /i'/0 O \\ o 0 0 \I �� \ �\\ / / o o / _ _ / o 4111 001- 01 o ° ° °OOOOOOOOOOO000 00\\�\� \\\�� /'/ /°°°`/` / i o 000000°off �0.0�000 0 0 000 / 0 00 00 0 0 p0 0 °° \ 0 ° ° ° o O o o o/ ° ° ° ° ° ° ° ° ° ° ° ° ° 0 ° 0\o 0 ° o o ° ° ° ° ° 0 ° ° 0 0 0 ° ° 0 0 ° 0 ° ° ° ° o o / o ° 9'o ° ° ° '% 0 0 0 000 °° °°°°° 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 °° o a o--0-° p /� \\ — _ ----- - --a�0G) - ----- ---- /N000In / r _ 00D ----- -- / \ \ _mo<- / \ o_oD— / Uzi \ _ ---- --- D -- -- ? \ Km0 \ _ - In — -n \\ \ \ rr Z \ - - - - - - - - - - - \ - - -MATCHLINE SHE C4.3 00 THIS DRAWING PREPARED AT THE co • CHARLOTTESVILLE OFFICE TIMMONS ROUP 0• •• YOUR VISION ACHIEVED THROUGH OURS. O t" 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 �� 0� ✓t TEL 434.295.5624 FAX 434.295.8317 www.timmons.com ti Nz Z I o \�• o ¢ ,- _ o R I O POINT N >; m m A v O DATE REVISION DESCRIPTION NOO r z CO o COUNTY OF ALBEMARLE, VA N m n 70 o 2 m z 00 N 1 Y� VIt�+t�� w LAYOUT & UTILITIES PLAN A ` These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express w itten consent of TIMMONS GROUP. F- i:N 03k16883-Wetsel_Property\DWG\Sheet\CD\46883-103-05.0-GRAD.dwg I Plotted on 2/7/2022 11:12 AM I by Jessica Danko I / \----------------- \ \ \ / \ \ \ ` _ _ ' ' / / / / / / I I ` — — — — — — — — — — — — — — — >Q \—a\ —` �\ \—\—\\\ ,/1r'\IIII�IIII .\ r\— //>—. /—/ \—_-4,�64—n19T �p —'\' - —�T\. \ — \\— m� —_W\— w C�t3 `=.r\l\i\—. w�—oN\ �\ -_ , _—A�j,4:`'\�.4_.'M `.�—_,•a�.'. \ _N—\ -0 —\ —\- Na— o--\ —A\—\ —\ —\— \aN--\ `` -\\-4—4\\-46- 6�3\2 `\ \1- \\— - � a-\a_\\� -�— \ \-- \O0�_\— I � —p -- — — —— -- 'v\_ w\ — /.-\.//\`•r.�, '1.1�Nr'.`?\<7\/�\.//�;�\. ',�S//�'�' ./. Cl) DD ————— — — — ——— ZZ �O O -- — — — —— - 445 444 446_ 447 Mi 448 \Cyril 'Tz o EMEEM _Dm '/'/// '/// '' \ / / ^'/,.'•I/ fI.>1.. .��;'.,,i.I,II l .l ,. 1 / I .�/P//�/.� P' a/' / � ,' �—I ,c/n �1-- -- co C Co mz 3O m m r' o ---1 OZ Ch c-oDm Cam EVEV 00 m0 It 6 MN0 rn iI / 1I1, II II I II— —I II III IIII 1 I\/I I I I I II I1II 1\III \I/I I \I �I III I I I II I I II�IIII II � IfI I I It IIq0 ICD xAS° It DZ , 0 If �zm AA 3 Z-0 N Kp \ Kill" C: pin -i\ Z O mD m Mm D CD \zm Z -n O (ZII �m C Z - I / IN II I it mumorm Ln I I I II As \ \ r I 11 I I I NAP 0 4\ I I 11 rl \ I Mi \ V a 1 III I RI IL \ N0 NVS wo ;I p621 1 i \ I I I p 00 �1 JIM 'iIININ0IINON �� \ 1 1 `Q \ 1 II p I l 1 \\ \ — = I 1 1 I m on \ w I I _ _ 2 w 0 \ I \I \ 1 \ I \ 11 11 I p I I \ \I I \ \ // — 1 1�-li; D � --I 1 I / D n _ �cnl I l I 1 I I I\ 1 I \ a l ho Cn M ......... i IN Miliff m ME u r_: = e e e ,u� —� ■ P.' '1\ 11 1 1� 1, I 1� \ \ \\ 'Pn00 ��I \\\ ,. \ \ \. \ \ \ // \/ / ' I \II \ / / I 1 To 1 T m z m A I m90 1 1 1 I\ \g66 \ 1 1 K Z $n,l"m m I 'mLn \0 p \ s M \\ \ 1 ^' \ \AdjI \ m I am 1 1 00 �mz \ p \��,, \ -71 1 0) \O o \1 w\ p.� I r—TI 11 1 \ \ 1 \ r0 \ \ \ 1 a \ \ \ \ Li9 \\ i ` \ / '1 1 0 cn 1 ji— ti MATCHLINESHEET C5,1 TIMMONS GROUP .•-':'•. n III O 1 p o 0 RIO POINT COUNTY OF ALBEMARLE, VA GRADING & DRAINAGE PLAN THIS DRAWING PREPARED AT THE YOUR VISION ACHIEVED THROUGH OURS. CHARLOTTESVILLE OFFICE 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 TEL 434.295.5624 FAX 434.295.8317 www.timmons.com �Na N >\ m Z \p V II n m m z Z N i O m DATE REVISION DESCRIPTION n A O These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express wdtten consent of TIMMONS GROUP. TH O000s Y O CRMG W. J. KOTARSKI Lic. No. 0402048507 .�,.02-0�-22, n E 0 N OV N a > E ° E w Lu LL LL o w O L M Q J U W Z w i — vn O N V {/1 V W L W r Z H Y � � 3 0 U) n x C N >� z O_ xcv c vn U1 NLLJ i M � W J ui 0 O x C7 0 x 45 458 \ �\ \ w H SEDIMENT , ' - - _ -R - _ -------- -- _ - / / 45 460 • o Z u of / /' / FOREBAY GABION- ' _ S _ - - - - ' / 46146 4-- • \ \ v� \" \ \\ o / WALL ELEV.=A47.0' P 464485 \\ \ r \ \ \\ j DATE ' $IORETENTION 29 ' _ - _ _ , ' ' - - - - - 466 - _ _ . \ \ \ r' n \ LEVEL 1 - - - - 467 \ A ti r 0210712022 804 \ \\ r DRAWN BY u7 448 / \ ' 449 _ R. VAN NIEKER 4y24ys / ' \ \\\ DESIGNED BY \ a \ \\ \\ / \ •• J. DENKO 456 46 ♦\ Q\ / CHECKED BY —Z — 455 ' ' ' - s \\ \ \\ / \ / SD CURB INLET W/MHD • / — — 457- _458 - - - - - 'I I 8 - _ _ - - • \\ n \\ \ \ \\ / / NOP= 4497' 15"RCP o \ \ \ • C. KOTARSKI _ • \ \ \ \ \ �\ I INV.OUT=449.84' 15"RCP / 1 459 I - - - - - - - - - -- i\ • SCALE ass s�rrss sss-Gssssrasras�sss ss 1 s j s s s ssss=s-�sssssss sssssssss���-ti�ss sj — —____ V —_ \ \ • \ \ � 1"=20' / / 1 h 8" HDPE ROOF LEADER _ —1 I — — — — _ _ — — — — \\ \ / / • CONNECTION AT ' ' ' - \ / h 1 MINIMUM 1%$LOPE. I EXCEP N8; OWES OMMUNICA ONS Q ORPOR ION \ \ \ A D 1 _ - BUILDING 8 1 DB. 13P 352 BUILDING 9 �' I _ _ - -�'' � NCO / TYPE D a TYPE D - - SEE v T N "FFE=456.50' , 1 , , _ _ •FFE=459.23' — — 1 I I — — — — — — \ a 1470 i rn Li •FFE=467.17' _ •FFE=469.88' 8 1 - " HDPE ROOF LEABEF� 1 ( \ I \\ ' - I 8" HDPE ROOF LEADER CONNECTION AT / 8" HDPE ROOF LEADER 1 - -CONNECTION AT o 471 C NNECTION AT ' t o / —MINIMUM 1 /o SLOPE. 1 _ \ \ 9 MINIMUM 1 /o SLOPE. / 1 - \ \ \I 41 \ - MINIMUM 1%SLOPE. 1 \ iN Z 1 1 1 m \ 1 \ Q SWK 1 ' 1 / 1 \ A �J^ SWK ' I I \\ ii \\ \ / / CIL PVMT ' • — -1 / TC 2.20 s s s s s s s / PVMT 469.47' I \ o \ \ \\ / / I _ L Q 46.'f�_ r• sssssss�ss67.63'�/ 468.88ssssss ss� I \` Q \ \ \S , 1 w (wD TC 470.41' I \ \ 1 / L d' Q SWK -TC SWK TC I I I \ / O w 466.78 _ 467.8 ' 469.38' 469.6 ' TC I : I II I \ '/ i ED EV EV i 0 LL Tc - a7o.o7' a7o.15, 1 I � / I n 06 467.72' TC 468.04' (/ �` \ �i !�� I I ` V 1 I I I I \I \ / O I z (D / I / I I I i 1 1 \ �i O TC To/ I \ I I I \ / 470.56' 470.89'I / I\ \ I / . I I I I\ I / i 0 Z W / / A61 —W W tob' W cp°5-W b V: �\/ / b• �10 e / 4 .40' PVMT- — l i ' TC 9.4 \ _ SWK I I VMT 467.13' SWK � 8 a TC 4 i I I 467 74' / ' \ \\ \ . ul -6 .^v T`, I i ice\ 6 5' SWK 4 0' 468 52 ..- .. .. . - . .. ?'. .., ,.•, SWK \ .. �- SWK 470.95' 467.59' 469.93' 1 E ' 470 I / I I \ / I TC BUILDING 1 I� 8" HDPE ROOF LEADER BUILDING - -- 1 / 463.13' CONNECTION AT 1 .J.. /� / TYPE B \I TYPE B 1 it MINIMUM 1%SLOPE. •FFE-470s0' •FFE=466.15'- - - JOB N0. _ 1 TC 46883 )� )♦ r' )� )♦ ' )�- -)♦ )� )� _ )♦ )♦ )♦ )♦ )♦ )♦ )♦ )♦ )♦ )♦ )♦� )♦ )♦ )♦ )♦ 1 )♦ )♦ ' 1 " )� )♦ )� )� )♦ )� SHEET NO. 1 1 / MATCHLINE SEE HEET 5.3 I - „ - C5.1 r - _ \ ' SCALE 1"=20' SHEET C5.0 SHEET C5.1__�'J I/ MHD l I TOP=441.24' 0 20' 40' _ l I INV. IN=429.86' 24"RCP BOT STRUCTURE=424.04' /-�- a \\\\ ,-�-/- \ SHEETC5.2 HEET;, —I SD FLARED END SECTION -_—_---_-------------- ----- ----------- OUTLET=428.45' \ \ q"' o \\ \ o 'Oa \ \ SD INLET W/GRATE o v \ \ TOP=446.25' _ —� \ INV.IN=432.05' 24"RCP \ SHEET 5.4 HEET C5.5 JOHN WARNER \\\ INV.OUT=431.80'24"RCP \ 1 \\ l' N------ _ - - PKWY \\ EX &URB \ \ \ ��---- — __�-�_�, \\ KEY MAP \——— — — —\?— ———————————— — _ _ _ _ -_ ------\--------------------------------' / ---- --- -- - - - - -� \ \ SD CURB INLETW/MHD PERM.1DRA- PERM- - \ .\ - _-------_ _S— ---- v \------- --------- ----P----------- - - --- - -- --- Y,\ TOP_ 447.65' EA SEE 7Da-PLAN�INV. IN(S)=442.05 15"RCP INV.IN(N)=433.70'15"RCP— -------a --- --- -- ---____------- - - - - - -- ___ INV.OUT=433.65'15"RCP fXMp PERM. S = -- - --------- --- - I -'' J — _ — • \\ \ / a c m a m fe 0 N 0 3 a a 0 o /r n0 vz vZ a0 o c m r- n m a0 O w (� r, Z zN O d o F m `o� o a N m .Z Y � N X C 0.0 _L. O 2 E m 0 m 06 a c 2c 0 a 0 WoM. M U c m m o c � m 0.E �v E L SHE T C5. HEET C5.1__�- SCALE 1"=20' / N I , I %,` // 1 MATCHLINE SEE SHEET C5.0 L43 - 465 33 0 20' 40' �/ �/ 1• I ` 1• 1• /` t _r �/ ` m m m SWK I ; , / �.X•ti �. / q U OW(; W. I. KOTARSKI Y Lic. No. 0402MS07 wTC .•. BUILDING/f 1,4 02-0-7-22 463.22' / 1 TYPE 9 SHEET C5.2 HEET, / , / ' " / / ' ti'Y��1 FFE=468.15's110, f7 ///,ir��-�fr•tr� /.-/ BUILDING 10 z TYPE B /- 4 -FFE=464.95'.n2" HDPE ROOF LEADER z \ 1 s Tc TC 0 /i- 464.22' 464.26 N wCONNECTION AT , / W / I rc rc/NC5.4 HEETC5.5 ,,' / /MINIMUMI%SLOPE. / ,' /' / ' \ i 464.16' 464.32 r > E / 1 T 1 1 W �E / I 1 1 Q LL a l _ _ - - - ■ W o TC TC w o / / , / / / / / / / / / °• / / I / / / TC 1 1 463.96' 464.041 / i Q J U 00 z _ SAN v6�SAN w - v, O KEY MAP / ,' / /' / ,' / / / ' , 'FFE=451.00' / FFE=461.6T / - / / 462.39 ) _ r Q .. o rn EASEMENT / / / / / / <' SWK / 463 /TC � � z � � v u 461.58' / / _ TC 463.60-1 TC ?' O m w • f 463.46' 463.57, M p = c N C1 -r w ,1-- 1 � V w I I , I ' I I / / / / ,/ / , / , , / �/ -, ,/ / , I�.i� / I I `� '..y .> / r 1. ¢'^ O /PVMT �� .' /463.00' - 36 v M Lu I I I 1 / / / ,' / , / / / - / �' 461.05' / f W W T o_ / I / SWK TC nr ffI +- 1 234 461.49' y / , Z :� / c f� 235 TC A63.23 TC I I - ' AS 46/1.49' \ \ I 62.45q 63.0 i `, 463.34' / Ln / 46 .44' ,' /' O BUILDING 13 TC TYPE C O C TC 462.90 I / / / / 1 / I , 461.65 I / TC , I I I I I f / / / / T '46 .22' / O 4 1.39' / / / > W w H 1 TIC TC I I I I I / ' ' I / I I 1 4 1.28' / L r 461.9�' 462.1 / U Q O I I / / / I y I I I :._L-_`_ , v/ / , t�.�, , BUILDING 5 w_ 0 / I z z � 0210712022 DATE D TYPE B rn > / / •FFE=465.03' rq Or I I ) 8" HDPE ROOF LEA ER \ \ 1 \ i ' w DRAWN BY z R. VAN NIEKER Q 1 . / cONNEC TION\AT I MINIjVjUM 1 /o SLOPE. 1 F 1 I I \ \ \\ 1 \\ / Q DESIGNED BY ISEDIMEN/I FOREBAY GABIQN h.. 1 , / •• J. DENKO I I ° 1 \ \ 8" HDPE ROOF LEADER I WALL ELEV. = 44/5.0' \ CONNECTION AT I I I I � 1 8" HDPE ROOF LEADER - \ 1 \ \ CONNECTION AT o CHECKED BY 1 MINIMUM 1 /o SLOPE` 1 _ , • I I o \ \ MINIMUM 1%SLOPE. C. KOTARSKI fc z _i', \// .r /461.70' /' • • 1 1 I 1 I I I I I 1 v I I t \ 461 SCALE I I i I I 1 I II I l\ I I 1 I \ I \ \ \:,,_ \\ \\ / / / / Y.-T`` • 1"=20' col I:., \ ' \ 6 - / / , / \\\46033' 1 ,■ ,' // i'/ 464 SWK TC-)46158' BIORETENTION 1A \Z \\ \ 1 210 ��� :, BUILDING 11 It / / TG 41.74' / LEVEL \\ 1 �r���"•� ' TYPE B PVMT -FFE=449.49' \FFE=460.17' 1 - - _ _ _ -"- 1 -FFE=462.00'_ - - - - - - - - 460.99' 1 _ SWK CIA cn 461.07' Q CL ___ _ i --- - - - - -- 1 ~ > Cu BUILDING 14 - - SWK _ - - 1 ., TC g ' \ 4bg-7 460.25� TC z W TYPE C - 460.99 -1 Q s 232 TC _ _ _ _ H� Q Tc 2 ' L z \> \ \ \ \ \ PVM 46010' - - - - - - - - - - - - - - 460.41', 231 60.83' - \ W I I I I I I // lr I \\ /// /// \I \\\ _ 460.03 - _ 0.4 Q Q _ _ TC -y \ SW - - i 46 460.7 '- _ \... LD \:✓- O O 459.70 TC ,..: s - - - - - � ' rWnn 4 9.99' TC TC TC \ V _ 460.18' 460.0 460.11' vb, TC I \ \ / / \ \ _ _ 7C- _ _ _ - _ 460.84 \ Z 4 9.95' \ \ U Q \ I \ \ \ \ I \ - _ _ - - - ' ' \ \ 1 - _ TCTC - - - TC / TC TC \ \ \ \ \ \ \ \ \ \ 1\ ` ` -\ \ \ \ \ \ ^ _ _. IA, Q 459.98' / 460.48' 460.62' \ \ \ -9 9.73 \ \ \ \ \ \ 8� N \ \ \ \ \ � 1 " HDPE ROOF LEADER \ t \ \ \ \ \ \ \ \ \ 1 CONNECTION AT TC 45 459.39' MINIMUM I% SLOPE. 1 459.00' - - _ _ - - TCO) , ' TC� T ----- - - - - -- -- - 59F12' 459.75' l 9.94' \\ \ --- - - ------ - ----- -_1 _ _ �Y~ °° ° TC \ Tc 461. 9' \ \ \ 458 - \ 457 \ \ 454 453 - 452 \\ 451 450 \\ \ JOB No. `\ \ ---_- - -448 \ \ \ 449 46883 )♦ )♦ )� )♦ )♦ )♦ )♦ )♦ )♦ ` 447, \ SHEET NO. A HLINE EE SHEET C5.4 \ \ \ 446 445 \ \ \ ` CiJr.2 \ \ ' - - - 444 \ - - - TC 459.06' TC TC 459.94' TC 4 0.09' \ \ \ \ �451 57'' \ c a ._ c e a m fe 0 0 0 s 3 a 0 a0 o n� �N vZ a0 o� c m -6 c� m m 0-0 O w (D � Z � 0 w 2 $ 0 w `o= o o N a m m 2 Y N X CO 0. ,L.. O 2 Z �0 E 0 m 06 a c 2c !0 a 0 m o m m U C m O c 0 m O.E h w E L a •1'I ' SHEETC5.0 SHEETC5.1__�'J 46 MATCHLINE SHEET C5.1 \ l� >r m m Emu m >• t m t � - -imp I l• >• >• >• >• >• >• 46s.a7' -mmum ME m M tl >t m m m m m m m ">t Jon 1 ��� I •. I 8" HDPE ROOF LEADER BUILDING6 I --�'------ `��--___- d//� ` � o � 8" HDPE ROOF LEADER <'-. BUILDING 7 I I ; - _ � I I I cxA1G W. J. KOTARSKi CONNECTION AT I I CONNECTION AT TYPE B I 04 ' MINIMUM 1%SLOPE. TYPE B I I MINIMUM %SLOPE. rrc=wvav / ; •/ I \ �I +d�o02-0�-22� •FFE=468.15' I / / - '/ I I SHEETC5.2 „HEET7,/5 II �Is c I- I / / / I srb \ \ SIONAL --TC • _ I - - - - - - - _ N w 4 _ E ' 240 / 7 C 68.8 TC _ o 69 52' I 1• ../ TC 4 8.93' TC _ _ _ 806 �1 I \ I 1 -I N c TC - - - - ' - TC sass' ass.3s I 1 - - _ , ` 1 I SHEET 5.4 HEET C5.5 4 5.5 ' - - 466.74' �\ \ ¢ E 466.85 68.09, / \\ UJ 469.14' •I' TC 465.14' =w 3 I y 3 TC LL TC - •1 465.40' 0 W o 468.58' TC --�-�---�- � w0 m.-1 4 468.49' .46 _ TC cb r . aw um z SA 6S - = SAN SAN - - S N SAN SAN 6 469.10' 468.90' pO v I 406 I w - n O - / - W r Q EST COMMUNICATIONS C XCEPT TION TC 46S I KEY MAP a N N N TC 4 PG. 412a65.15' SCALE 1"=20' z p 45.86' I H.� U TC TC 468. - _ _ EE VD LAN 0 20' 40' o a ¢ o ----- ---- ------- _ ---/ TC TC 467.j1' E - _ ix vw - cy�n \ 67.72 I \ TC I = N z n3 n3919465.47' \ / - Zl n3 r3 7 TC y� �I \ 66.13' = V Q p / TC \ 4fi7.5T 438.34' .. �.`. •. `TO I cn PVMT 23$ PVMT \ TC s -' x 1 :•.. \ I a, > 464.26' SWK _ T _ 466.28' / SWK 67 48 468.10' 464.82, - - - - - - 65.40' 466.86' _ TC 46% C Y I 37 y 467.45'm 'him I •I � o w ----- - ---_- '---------� •--------- /SWK -� - SWK _ I--------�� I\ V) I I- � ' 464ss' 404 I I � i I \ min I ■ - � I ■ i / ` I I Q60 D F i _ BUILDING 5 BUILDING 4 \ \ a s70' w , TYPE B TYPE B Z , •FFE=465.03' �.•�' •FFE=467.25' - a , I � 1 8" HDPE ROOF LEADER 8" HDPE ROOF LEADER I ' CONNECTION AT CONNECTION AT'- MINIMUM 1% SLOPE. ' MINIMUM 1%SLOPE. I ,; D K I ob - wom NO - ---____ SCREENED ' PORCH y - - - -405 ' AMENITY z' GQ--____- - z ,I Iv \ I I I I 1 • \o O� a 0 m aQ ce ... \ w w \ \ U \\ I \T\ z :I I �I o \ •I C (n DATE 'I 465.73' 0210712022 •I b \ p DRAWN BY 1 •I \ 'I \ R. VAN NIEKER �` I •I DESIGNED BY • J. DENKO III II I \• ' I • CHECKED BY \°\ I • C KOTARSKI 1 III II \ `\ I • • SCALE \ 1"=20' I a`Oh '� Ni I � \� I • TC TC L 1 v \ I \ 4 4.39' 46 .25' 4 2 464 463 ENTRAL P SEDIMENT E,AINGEPTIGI \ \ - I •FFE=463.75' I 1 V d PG. 2 I 01 462 461 SEA VDOI P N \ I Z 1 I \ I 8" HDPE ROOF LEADER CLUBHOUSE I 15 460 PET SPA 400 1i \ o CL 1 rt r CONNECTION AT •FFE=466.20' I \ m \ \ Q MINIMUM 1% SLOPE. I Z I ' \\ Ifll�l MAIL I \� 463 I = \\\ Z L KIOSK & � 600 �\ \ \ PACKAGE I - - • \ \ \ ~� Z ROOM 463 I TC 254 I ' \ \ O w I " SWK _ --so- SWK •�� 3.89'I _ \\ 02 Q LL I NO NO 46397 - ��-� 463.9 -� 1 242 0 TC PVMT \ \ TC SWK PVMT TC I 462.E - \ \ \ pV 463.46' SWK 463.34 466.0 64.55' 463.63 62 95 I 53 \ , _: « \ TC 462.87 461.71' \ \ 463.81' TC O Z - - I \ TC \ \\ \\ 46Tca 252 ; \-.-.-.-.-.-.W RInRF W 1 462.5T I I \\ 8" DIP WAyFL 1 I I 462.14� c\ \ N \ 1 I 0 1 \ \ \ 462 �S� Q6y' P� 0� \ TC I \ I I \ �` �ro� 461.98' \ I \ S CURB UT \------------------- 4--------- I, Ar TO ..■- .r . TO I S7 \ b� 5L462 :462.19' . I P \ 126 464.09, 461.75' - 460.07'I -.- _.-._._.�.-._. 462 I TC 1 I \ \ 461 _ a61 \ \ \ 2 459 460 RAVEL 4S6 us 4 I I 5p \ \ 458 cP Sp TC I 461 457 \ 45 sr 4&2�s 456 455 IMENT \ I I C 460 \ \ 459 4�y AY GA � so 7 -i 458 R NTI N \ 453 457 V 1 I \\ t 504 452 451 450 2 c ' \ \ / I JOB No. 448 aas s.a7� 46883 446 _ _ _ SHEET NO. \ \ _ 444 445 MATCHLINE SHEET C5.5 T� 258 I \w C5.3 \ •FFE=467.40' \ \ •FFE 467.40' \ BUILDING 3 (6) TOWNHOMES (3 STORY) • r r c=voo.vu • FFE=466.40' \ •FFE=465.40' • FFE=465.40' a 2 c a m fe 0 w 0 3 a a0 o cD nco co vZ a0 16 c m r- C N �m a0 O w Z od a 0 w `o= o a m m 22 W N X C m o .L.. 2 2 c c E m 86 06 a c 2c 0 a m 2 m m U M m 0 c 0 s. E h w E L F- 1103\46883-Wetsel_Property\DWG\Sheet\CD\46883-103-05.0-GRAD.dv✓g I Plotted on 2/7/2022 11:12 AM I by Jessica Danko n N I 1 O 6 -----sue J T� N C O (n y m m M�< m. � � mNIy m� zN�rn -< p o / nw�10 / + / Z C/) / O Z / I I I I I I 1 I I I I r I I I I I I I I I I I I I I I I I I I I I I I I I I II I I I I I I I I I I I ' I I I I I I I I II II 11 I \ I I x / I / I I / / � 11 11 I 11 II 11 \\ I v I I 1 I 11 1 1 II I 1 I 1 I I I 1 1 \ \ / I \ \ 1 I 1 11 II 1 I 1 \ \\ v \\ 1 1 I I 11 1 1 1\ \ \ V \ \ \ \ 1 011 \ 11 I\ \ \\� \Ill A 00CD ai \ \ p / N Cl) / / /N 1 I 1 1 1 I , I I , , I I , I 1 � I I , I I I I I I 1 I I 1 I I I I I I 1 I I 1 I I I I I I 1 I I I I I I 11 I I I I I I I I I I I I I I I I I I I 1 1 1 1 11 / II rii / 1 1 1 1 1 � \ \ \ \ A O / / CO vcc mrn n co 4 Oj I A CH NEE SHEET C5.5 TIMMONS GROUP .•-':'•. 2 m 0) O �o Wo RIO POINT COUNTY OF ALBEMARLE, VA GRADING & DRAINAGE PLAN THIS DRAWING PREPARED AT THE YOUR VISION ACHIEVED THROUGH OURS. CHARLOTTESVILLE OFFICE 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 TEL 434.295.5624 FAX 434.295.8317 www.timmons.com r%ATG DF\/TCTn Nl n PC:('DTDTTr)NI 0 �M v a N m Z �p II n m m z Z V N i O m m O m rT1 ON m � A < N i � A A � cn ' A / A These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express wdtten consent of TIMMONS GROUP. F- i\46883-Wetsel_Property\DWG\Sheet\CD\46883-103-05.0-GRAD.dwg I Plotted on 2/7/2022 11:12 AM I by Jessica Danko MATCHLINE SHEET C5.4 v I -4 A I Z / ' / / I I I 00 N > O / m/ / /' I I I coo r- ci 1 -- -- gym. D. ♦ TI �OM In M OIn ` m O O m = O Z OCO�cn /' / ■ / z < D Z / C/! 00rn (31 • �\ / / / / — — 428427 / y / ° \\ n� J ■ // /// 0 4 43j3p29 �► . .. , \ \ r (� \ / / ' / / / 43534 33 32 — — / \ — / IN 41 % ` 45,4 DAr— \�454 \ 455 \ • ° °D \ \ \ \ N / / / 456 457 D \•\ \ \ \ \ \ V' o' n ' \ s VS NVS NV Oak* --• -- \ „ m ``oftft a ` In 1 W m UNi T 1 = gyp" \ T m \ N .1171 6i JL o Cl) 00 02 m m \ (n 1 ^ • T m 41111111111, Min ' A. �� V \ m m r r•I�r�•'I� N A O Cn p /n O \ 1 D- c 83 1 N 0 0 1 A 1 < m m m 1 �I _ �T 1 A O' O °m 1 ywit Cb 1 1 rn m 1 rr ii LU - 01 in 0 X4 boa 1 D S " 1 TIMMONS GROUP 2 n m O 1 (� (n zz COo GJ RIO POINT COUNTY OF ALBEMARLE, VA GRADING & DRAINAGE PLAN 0 THIS DRAWING PREPARED AT THE • • •• YOUR VISION ACHIEVED THROUGH OURS. CHARLOTTESVILLE OFFICE • • 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 TEL 434.295.5624 FAX 434.295.8317 www.timmons.com A 0 DATE REVISION DESCRIPTION >\ m � N a II U Z p V i n onm z Z N i O m O m < 0 m A N These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express w itten consent of TIMMONS GROUP. SCALE 1"=30' 0 30' 60' LEGEND ------- _ --7i-- ------ - - - -- =�--- - — -- --- -� \ - _ ---__--- _ _-- �/--- EASEMENT- -r - ARE C � -- -- ---- - - - -_ - Jy - ---�EEVUOVPLAN — --- — a ------ _ _ INLET - - - - - - - - -- - - TC=TIME OF CONCENTRATION DRAINAGE DIVIDE- ����� ROOF DRAIN/PIPE CONNECTIONS _ — -____- __ \ _ 53 75 RCP _ --_ - _ l \ \ FkA(tED E OSEC7IBN / � / \ / \ INVIN-{ / / / PERM. PROP FERV BIORETENTION LEVEL 1— \ I I I \ `� \ 1 �I I � 602 0.48 i \\ Tc=6MIN I II \t � I\ 15' S CK FRO \ \ n PROPOSE \ \ P OPERTY LINE ,�XJLO�F L,,HP U CRAIG W. 7. KOTARSKI Lic. No. 0402048507 e.02—O—2Z n E 0 O " N u N c > E \ W v E \ I.- W rV 3 LL o LL K O L Q J U W Z w n — O 1" LL{ll raj F- LU R / 3: o U�) X n J Q W lL U) =U>O c n N W OJ J O W � H Ln 0 0 W W W H U Q Z O in DATE I 0210712022 I 0 r DRAWN BY IR. VAN NIEKER • DESIGNED BY • J. DENKO / / • CHECKED BY C. KOTARSKI • • SCALE 1"=20' I i • � I I CL CLL G Q W zw� J H� Q Q OLu W W Q LL O z O FBI z oC o 0 W J z n \I JOB NO. 46883 SHEET NO. C6.0 5 a d .y U C fe L F_ D3\46883-Wetsel_Property\DWG\Sheet\CD\46883-103-C6.6-INLET.dwg I Plotted on 2/7/2022 11:13 AM I by Jessica Danko o I / D I j I I I I II I I I I I D m o I _ rzo — � AV 1 I 1' ZnT I rn 11 (Ml m m 1 vv� ornn Z i` / \ I I/ I 1 .1-O p I if I I / p0 p / \\// I I ' of M. (66 ViEV m �I I 0) 3 �- Z ZII CD OJ / rin rn W 3 O�— r /l I N 1 O III I / II III III 1 III III I\\ \\ / 111 I II 1 1 III I 11 I I I I Z I O I I ' I / inZ _n 0 m D 1 I 1 1 I \ \ \ \ 1 II O N 1 Z O \ rn r) O N \ \ \ \ \ \ \ \ \\ \ \ \ 0)O 1T \ �\ \ /4,\ / 4a��n w O O \ I \ I �T W I C) / II O W II O Cr 0` N 1 rn 0 O I rn I o) o O O O 3 3 N '. 3 '(� ' 3 O I O I O\ Z z I 00 z � If I I �$ / 241 �m�0 / I I n� CA) /limo' 4 4\ N U ■■ II O W I cn m rn W N -4 Z 3 O O M M I O O O W N N S W O D 1 w i 11 o I o I I O cf) O Z O I z 0) f \ / / m 3 J 0 \ / = 00 m M 'O \ dH0 1/ ti n o' \ I 1 \ \ \ / — \ \ 0� -- \ O / / n O I /, II O N If O rn w W O N ` O / t.Z W W 0 y _ ` _ _ \ _ _ — — _ 00 C:7-7 403 d . CD a i I i r y mru0m 0 z 0 O� II O �P � O 3 v � n O z mQ _ .. 00 If — — — — — —�. \� �\ / / id£9 31/1021I 1SV3Ob'02! 0 • THIS DRAWING PREPARED AT THE CO • • CHARLOTTESVILLE OFFICE pub TIMMONS ROUP• • YOUR VISION ACHIEVED THROUGH OURS. y� n � 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 y�9 �i; TEL 434.295.5624 FAX 434.295.8317 www.timmons.com O No q rt A DATE REVISION DESCRIPTION r O o ? �= 0) o RI O POINT 1 N m o m o ' o� r z o COUNTY OF ALBEMARLE, VA N m n o 2 m z N 1 rN� :a11St�� w INLET DRAINAGE AREA MAP ° 70 ° m ti A These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in pan and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express w itten consent of TIMMONS GROUP. r a:a uaw0000-vvecsei_rmperrywvvwran Be Ura000a-Ius-Ui.U-0I UKNNVAI eK UKA11MAUM AKMA.°wg I rwae° on ZrrmuZe -14:sZ r1W I oy KIKI van IVIeKerK 1 \ ° 0 0 0 N0-01 0 0 \ °M °° °\\ \\��\\\\A/° \ �\ °��° oa °°° °oo � °�o °O° °0\° °° O O O O O O O O O O 0 0 °\0\°°O ° p° l I I 07 /o 0 0 0 0 0 0 0 0 0 o awe o_° Oro °°00 O // \\\ O ° oo0 � o/ \ \\\\\\ \ \ \\\\\ \ \\ \\ \ \ \ \I I \ \ \°°o / °� �// ° ° /° \ 0 0 // O /p/.p� \ ° ° ° °/ / ° ° / ° / ° _ ` ° \\� ° oho o%� / �\ \\\\ I I I o`\\\ \� e�o.a�' —� /00000a//P , j �\\�\ ' I I I \\\\ \\I,\111'II III/ \@ I I o 0 0 0— o 0 0 \�\ ` / 0 0 0 \\ II' 11'II11' I11 'IIIII h , ° \ e \\\ \ \ d 0 I °I0� I I o ° ��o— o "o o-a0 s�0 O-c 0 0 8 o \ �0 ° 0 r \� -:0 �� 1,III II �II1j / ' �\ 1 \ \ \\\ \ \ \\ \ \ \ \ I / fill, 111111\ 1 1 I11I Ill ll'r--' l � ` ��-_'��_�`_ ____ =,,_-.- ---_.,\\\\`>`,Ill I'1'1\ ;II'11►��II IIII,\\ 1, 1 l / / ��. \ `\ \\ \\\\\ \\ �\\\\\ ew It \ \ I I I I I ' ' / ' ' _--- _ \ �\\ `\\-_� \\ _ '/� / \\ 1\ \ItIt II\1I III I I111I I fI 0#100 // \1I 116111 \\ r I \ 1 �`` I 1 CQZ50� = 11IIIjII/I;IIIII II IIj'II I II 1 i I I / ,��II �` \ \\\\ `--— �.—CO�v Z �\ 1 1 ' I I / I l l /1� 1 I l I I I I 1 / i'' w< \\ ` \ _F �ZD I I I I I / r q v m \ Ill,x I yIr I I l I I I I I I / ' /' ? D OG Z O Im \ III /�/ II I I'I I I ' / I I I I / / F� — \ �\ \ O_ /I I I I 1 I I I I ' I / . /—mp \\ \ \ m� I / // //// /� I/ I, I I I , I I I I I 1 / ' Ch O �T rt1_ — Ifmn I L,,//l,//// / /�/ ,1j I I ; , I I I I I f I I , , / Z \ �� �\\ `\� --\ 1 �\ /I I I , I I / / // / r �, , l I 1 , I , , , // ,, �/, J , , I I , l , I , , ' I , , 4 \\•� —<fp r� \ ` \ /' , , 1�I— ' %I' III, II ' / m,—\����O\—� `\ 1 / / - O �v� 1 I I 1 1 I II I �� \vl �/ j I I I / , / // // // /l � / / / I I � I I I I l ,' w `� l\ ✓ — � � � � �.\ � � \ ,` \\ I II � / 1 III 1 1 ' ' 1 I \r- 2,00 0rnO/l \\ �\\`\ 1 I ' ,' �111 `� I I I 1 1 I \ ' / / '� EWE/l I LillII`�. It Ii i I, ,- ,. ..1. I.w `, \ 1 I, \ \ `\ ,I ; n\(n / / / ' I \ ` 1 \ \ 'm'/ /'/ ,''/ /,' , J ,' ' / / ` ` \ \\ ` \` \\ \ `\ r \ \ \ 1 1 \ 1 I \ 11\ 11 \ , /, \ I m \ \ Z �\ \ / r / ' ' \ ` ` DI I 11p4 1 1 1 \ \ \ \ \I \ 1 I / � \ `\ ` \\ ` \ \ 1 ' OZ 1 1 cal \ �'(// /' G ' / /' /' / / ,' /''/ ,'' /' ) \\ \ \ `\ \ `\ \\ I I r In 1 \ 0\C7 \ \ \ \\ \ \ \\ \ \ \� `I I 'I 11 I11 I I ; IOmOI �Z\ ' \\ \ \\ \\ \\ \\\\`\\` ` \T\J IIII II°I 1TI0 \, , ,/ , , , / , I , I I , ,/ ,/ \ \\ \ \ \ \ \\ r 1 , 1 \ \ \\ \\ \\\ \`\ y`\ ,I,I„/ I,I� 0Z�� \ \ I 1 r \ \ \ \ \ � \ 1 III 1 I I I I/ I I I I /.'/// ' // / z mP / � m Z I I I /I 1 1q \ \ \ \ \ n a ,7�{7 \\ \ 1 I 1 \\ I 1 \ \\ \\ \II II\D I 1 \ cp 0)M / g°m\ _ J LA / A \� 1 I mll \ / -dH0 --f�Ho /' 1 .�\,\ � '�' ""'� ; o- \\ — \ — 11— ' `l 'dHO °� �/MO 1 11','I I \ ' T 0 InIIII / J i \ I I 1111 z Z m q ' _ ' I 1� 11 , k \ �HO / / > I IIII I �111 00/ ' / I O / 4 ! mpr -�' -n a \ \ I � m \ \ / / , .... r 1 k'•�2N3 I I I l I I I � I l l���\\ I \ c1z;oTm n n rn ro Cn oboo -q rin ? BOO I / _ / / \ \ ✓ \ 00o TIMMONS GROUP .•-':'•. rnJ 0 THIS DRAWING PREPARED AT THE YOUR VISION ACHIEVED THROUGH OURS. CHARLOTTESVILLE OFFICE 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 TEL 434.295.5624 FAX 434.295.8317 www.timmons.com _ o RI O POINT N m o O DATE REVISION DESCRIPTION m o Z CO o COUNTY OF ALBEMARLE, VA it m n o z o z z N i o W o z W m< o PRE DEVELOPED DRAINAGE AREA MAP 3 m O m 0 O z n m z D z z These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. r a:a uow000rvvecsei_rmperrywvvwlan oUura000a- i us-Ui.U-0 i UKNNVA i eK uKA11MAUM NKMN.°wg I rwae° °n Zrrm°« -IZ:aa nW I °y KiKi van meKerK °- 0 0 0 0 0 0 0 0 0/ 1 0 ° o \ \O ° 0 0 °/ I O 1 o 0 0 0 \ \ \�!!1 \ 0 0 0 0 0 \ / ° ° ° ° ° ° ° °I 1 ° o ° ° 0 0 0 0 0 \ \ \ 0 0 0 I 0 11 ° ° 0 ° \ \ 'Q 0 \ D N ° ° ° o o \ \ ° \ \ o o \ o m 9p83 o \ \ ° ° o � oit r \ rn m o\ 0 4 m -� //°°\ \0° \ \ \ 0 o ° \ \ \ o ° o ° o o \ \ ° ° \ \ Q p °O0o° \\°o \ o \ A Z — D ° / \o \ \o�\ \ �\ I ° o 0 \ o / \\ \ \. �0 °o\ \\ \ \\\o O°° \ \ \\\ 0 \ \ \ \\\ 0 0 0 \ \ ° o 0000 °o\ o\ \\\ ° °° ° o ° ° °° 0° \ \ \\ °�\\ \ \ °°\ 1L ° ° \°°\\ \ I ( / —� \off \ �` \ \ \ / // � -0 °� —c OZ off° ° o , / , b �\ \\ \ �\ / / _\ _\ \o ° °moo\ — °�— / 0 0 0 0 0i0P' 9i _ / _-- / 0000 __-----__- q� \ \ / ✓ I I \ 1 I' I I I I I I I I I I I I f , I I I / i ' ' �_ � \ D ' V l ' I I I II I I ;I III I I I I `I'1 � 1'1 I I I 'I I /I ---I C) �1 — \ \ \ \ I I I I I I/I t ' I' I 'll I II I I I ; i / / / (� t I /' n I /,,1�1 I ? z0pmI rCnm / Ij/J/O Im< — 711 \4 T�L CI I I I I D q \ \ -7/ I I I I I \ \ \ / ( I I I I 'I I� I I I I I I I I' I' ' '' '' /' '� ` r \ / I Iy T �- 1\ I\\ ,� f; �..,•� .,: �..� �;..J,,,� 1. •.�� I I I I I I `` 1► to /, \ \ \ �0>-01 0 Z m o� \ m / Ali) / / / / / / , /, r �■/ / z m I 80 Z / / / / / z z IT m C>m \�cziIT � \ \\\// ■' --- �dvo�—doted C \ D� \\\\ \\ ''//——\\—�T�dH —dHO 0 CD IT Cn CZ IT CYIYO / �0>0_U \ 0z�Tm I \ n n \ rnco Ln6 CD gngy °�-m \ om< m ImD TIMMONS ROUP • • THIS DRAWING PREPARED AT THE YOUR VISION ACHIEVED THROUGH OURS. CHARLOTTESVILLE OFFICE 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 TEL 434.295.5624 FAX 434.295.8317 www.timmons.com _ o RI O POINT N m o O DATE REVISION DESCRIPTION m z CO o COUNTY OF ALBEMARLE, VA rn m a o Z m 2 N i o W. o A W o m m o PRE DEVELOPED DRAINAGE AREA MAP ° { A ` N 'b Co r �3 Os� � N z �r o- Ozy Nor R t/E, These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. LEGEND: LIMITS OF DISTURBANCE / / / /// // ///� / / �\ \ \ \ \ \ 4�1���7;/ OFL � t 1. 1. 1• DRAINAGE AREA DIVIDE TIME OF CONCENTRATION , / / / // / // // / // / _ \ _ \ \ � O CRAIG W. 7. KOTARSKI Lic. No. 0402048507 02-0-7-22 ONAL \\\ \� \�\� ---\ \ \_ �\ IIII` // / — IIII �// \\\\�\ \� �� \ \ \ — III / °U /� / \ \\ // W 3 _' /da '\\/d % / /O-�-�/_ \ ///- /\ I/\ -\-_ / n_ \ \// I - I\ / \ \i '/\ \_ \ /\\\\p\/ /°1/\ �i\i _�\Ii1)1 \ \ _,\l 1\)II// - \/\ \\\li\I \ '\`_ \\/( \1 '/I ` , \/ /� 1\/ I�- / //I _ // I/ /\ \ r,/` \III l /\ �-\I\/ - —�I , //Ii \ \/;�/ /II1II- 1_\ I /I/ -__' \/ ///,/1III/1\ /\\ 1-\'/! / / I\ /1//I- /III/\/I/,-I\jI I\\\l '//I//j-\1 /-- f _I _1 \ /i /- I l`/1 I\\l ✓/ _I/ \// \1 I/1,/ I'-1 / \/,_// \III'l / I ' \ J/Il/II/ ;\I/ / ''\✓I \I/1// I / I /1I �I\/ /I\I1\''/ I✓ /1 II / //I/ `/I `` /, /.I / iII , /\I_1 _1/IIl;'1/II ,-l' _.1/ lII \l / I- /\\1 I/I '\'/ ll\I I l- -l/ I \ /,^I/_//- I _1I/ //l%\�\ lIl \/ =I - I /\ I` ` /1,/\ /`\`' I/ 1/ \ \ / I-l\ //\\ �\ I i/ / \ / �II "- • r \\\/I\ I I / // \ \ ;\-'/\ \1 / I i II' �/I '\\/\- /\ /1 /\ /I I\�.' / , i./ //- //\ \1 /- \ /\, I ///�\ /-` \� I / \ II / � i/\I 1I\ `/�/ I' \ 1 ;Ii I / / I//I1I, // �\I\\I / �I//,1I Il/ I \/\ I l/ // \\ /,/l '\✓II %l \ I I \\IC\ \\///// l\ / \\ / I //,�/ \/ \\ /// \ \,lI/ \\\ \✓ I \\ i\�I\\/ � �\\/\Jl\/h I \\\ \% �\�/1r\\\\ \/\ r \ \/ �\dI\/_ I \ a \\\\Q I \I I\\I\I \ I \ \ `II/ 1 / 1 \ p\/ \\ \ / \\\ \\ v \\v\ 0te\\�d"l_r'T: \. . I\\I \ \III / \ \ � , \\ 1 I J\I\r` \I'\ � I 1, \\a \ I // \\l\ \ �\ ` 1I /I /'\//r\ l 1\\ \ / \I \I\ / \ , -\\ `L\I �...�':\ -\...A49 —v•6c rr �-' /- f - /-/- / -/[/1/ n_ / \�\'- _� _04_ -05/`__9- �OFi_sy�'. cf•;;- . _�.tc_I ^.o- "_. -." _./,I: --/ / -,\—\ . _ %a_ _.-•\' .-et , , - _.�r:-c/:-p �-:;—_\_ s-,-.'%\,- _-�*I -o..:-s.'r/'_.r/;\4,-'._:5': :/«\ .5 :r\ �:I1IIIII - \\i—:.':,hs..;= ._.' \ A:F\�•—_\'y \a. 8 l _,b� e g RI_�/h1 /I_ \/4' r/ _,E� \/poi-h0 / //` ,/° /_\1 11 -lcr_al-_-._//"..r r1_,.;III• `i.i_b�.—h':.en_t�o r./ -v/5d _:.H4 -0.-: i �—.,\ _> d^r�,{.:.Ir' .- _./.' /— 'r sr_:\e\` 1o. 6--A-/ _6S.' 1: } ' ' U \ :'_:--i_ss $i--' 6—«A' `/:/ .Y:- .»:•.te, --�r•4 III.II ' s...p.�ti.z:,h`4.4,,f;;=.,i_ :'� „o-5Fo. p°.._-� :-• '4"�ss E-�--:/.'- ./a\ ' g__ , �_ :_-gi __r0.• �.j.c' 4:r_,:,./—.-. _..--. :c.ta:—_ ._ . n_'s•x. — "1z—IIII i-i'}r; ':� ^ I \ I.0I \ I'I \✓Ii/- I l / /\ \ I/ / \ �do•_• •_j • xw N0 w •Nvv o N SCALE 1=60' CHANGEINSLOPE 14 SHALLOW T4 Lu POST -DEVELOPED DA 2A M BIORETENTION: CONCENTRATED \ AREA = 2.33 ACRES FLOW 85 /= vl POST -DEVELOPED DA 3 - 0 UNDETAINED: - - // AREA= 1.421 ACRES TRANSITION OF FLOW TYPE (TYP.) CN=55444d-4' TC=6.3 MIN. > wq: SHALLOW CONCENTRATED FLOW - \ 444 g45458�TRANSITIOu 4-9—FLOW TYPE (TYP.) pal -469 jdO`H�L L�� DAJEDZTE 100'OF cot % > 445SHEET' 0 02/ 7/2 0 2 /Q25IFLOW �p— �oo r DRAWN BY R. VAN NIEKEV 71 R DESIGNED BY O o J.DENKO 19g[a,_ - SHEET FLOW CHECKED BY G KOTARSKIo�° POST -DEVELOP EDDA \ SCALE ---- -___ BIORETENTION: i/✓ AREA=1.158ACRES i1'=20' 70\0 0 CN=87// ° TC=6.0MIN °o /'" './// °�°� // o o o 0 \R\ ,/ I i 39'OF SHEET FLOW 464 60 o !I 4 / rr 001I //I '01 1.1 1 1 1 lr I I I'7to o °\ \ TRANSITION OF POST -DEVELOPED DA 1 E - WET POND: p FLOW TYPE TP.) AREA = 11.03 ACRES CN=79 SHEET FLOW o � i / 0 o °\\ \ p 1 // SHALLOW TC=9.4MIN. 0 0CONCENTRATED FLOW°o pp TRANSITION OF po°o °FLOWTYPE(TY.)461 O Wp///� ° o � \o °\ SHALLOW Q d/ CONCENTRATED o \ Oo Q I� \ 1 I III I I 461 FLOW ° oI° ° 0 IIII I Lu Q /%/// 0 I°° o `l= I A6y � Z 0 ° pl; Q I IIII IIII° 10 p /46mO 0 0 p °- - - - o \ o Qo LL � _ - Lu ° L I O S- LPED DA POO 0 / o DAlB- 4 -�_�4\ 34\ •�419— 417 4P- 1O6-S4T-41D E44V9�1D�4"4t..4,1t"4"^4S,by vcr� 4g�yq/\/yg u/IS� " —1 ✓' fa ' / / 4�59B1°6E- '' 6 BIORE i' ON' T \ 1\ \ \\ `\ \ — .Uwo /0 AREA 1416 ACRES o o ° AREA=0.346R\ \ hCN87 rTC=94MIN.� / 1 w° ° If TC-6 MIN. 7\ ti_462 \ o /% o o / o O ° )o ) ) \ `\ `I _ 4 0 4 o °/ 444 ° °/ ///o ` 4 Y POST -DEVELOPED DA 1D 0 0 4<44' BIORETENTION: 0 ARA o\ - h E=0.743ACRES o _/ \ _ _ -- __- o o /42TC=6.0 MIN. ° // //o 42120 o° o418 o _ 0 p \ 0I 0�-'--1 p v `o POST -DEVELOPED oCO _ o o o0/ _ = OFF -SITE ROAD DA: 0 o / / AREA = 0.258 ACRES pp ° / \` \ \ - - _ _ - _ �4;4;4;4 44.4-4 /4444'•i 44�0 °'o-1 JOB NO. / l ° 0 — - -- - - _ \ !4%••, •47V•°G GGGV2 419 brn hr r / CN = 98 0 0 / / o / / // o /��� / \ / /� /�.' �' f 44�0 'rt,oJ�: \ / TC=6.0MIN. 46883 °>t >t >t ">t �il>r� i� s /it s />t >t� �, i� �� / i� s,» >t >t >t_ >� �r'>t'>t/fiy 44�5 � % \ \ It It It It 1� C SHEET N0. o °° / // \ ��\---�/// / �. —MATCHLINE SEE SHEET C7.3 i/� - co \ co \\ t ll / / \ Ci%.2 L I I x0\\\ / b/o ° A ° °/ / /% I I tI / / / / ✓ // / \ °\\ 1 \0 1 0 ° I to \ oo \ \ / / /// o o to I I ° \ \ \ °°1° °O I \ 0 pp ° O o \\\\\ / ll I \ , ,° ° / oo ° ° O ° 0 � 0 ° o/ ° 0 0 0 o� / l,/ o/ 0 _ ✓ / ( l 07 °/ ° °� / //°I / �o o / y //0 I I / �/ o ° ° / I o°° / / o°° / o / /� /" ° ° 0 oo / o / o 7 S S S S/ \ ° °/ // 0°° o // /�/ / / O ° / 000// oA 6// / I� / /l ° 0// O// jj//� o ° o // �O° / °�/// / 0o // /q %�/ /j j 0 / o ��/ / °°� j ° // °/ 0 I° / // / II o°I /I /bol° ° a II /0110 I II Ili/ ll l 1 POST -DEVELOPED DA I - WET POND: Ass' - ss _ sj 458: ho`b cro Q6 TRANSITION OF ily ) r .. r AREA = 11.03 ACRES / - I 85' OF a s FLOW TYPE P.4—- - - - - CN = 79 v ' 9 e SHEET FLOW SHALLOW / / / I C = 9 4 MIN ITI- - - / x \\ \ \\ CONCENTRATED T — — — -•. ......,, z; :,s:_; "•s: _ 467 { ... \ r_ \O \\ \ \ \ \ \ \� \ III \ 1 // / / / / FLOW / / 46> \ /\TRANSITION OF \ ° \ \ o 461 I / / / / / I g FLOW TYPE (TYP.) 1° I 1\ \\ \ 1 I I I, I I II 1, I I I I I I I I 1 I I 1 I I l I 1 1 / 3� \ // i / —/ ` b6 \ 4 \\ / o\\\ \\\\�II11111I III IIIIIIIl1/lIIl1 II 1 1 I l / /l I I .`sI 1 \ i yi....,:.�:..a•.:Y..x_a'.x:�_ / / z/ / I. O' \ o it /' I I I I I I 1 I I I I I / v — -- \ _ / / _ ---- --P b66 o 1 / / 1 I 0 :..,..:. .::...�.;.:_. .fi \o\� \ I IIIII1/ IIII, III, III I I I I 11. I 1 \ 1 I 1 I j bb, \1 0 \Ili l�lll///�///1I/I//�11/�465 Y \ \ \ , ''46 °/ 1\ �I I � � �/��// ,/ll////IIIII I Il 1 1 1 ( ��'� _ \ \�— __ �---- — — —I /� � ^• I. - — /y I 11 / lI l / 63 lo( _ ` 4s2 POST Pit - "6 -DEVELOPED DA 1B - I°I 1. / / / / / I I I ` \ / /_ \ \ \ — _ - - - / BIORETENTION: / / _ j //�llll / lI I I Ill I\`\\ \` \ --- --- 4s9 moo Rs' AREA=0.346ES CNR87 Asy \boM,` byry /0 ° / / _ \ \ _ - - - TC = 6 MIN. \ 4 �� 60 �° � \ � � \ � 458457 �459 464 I 454545°4596 3535544 ol Io \ aq 6�44444g4 - 439 I ° I I I SHALLOW CONCENTRATED( FLOW / 1 / 1 / POST -DEVELOPED DA 1C / BIORETENTION: AREA - 1.416 ACRES 1 / \ CN=83 -f TC=9.4MIN. \ 11 fl� Irf■ \ w 1 � 1 � \ POST -DEVELOPED DA 1D BIORETENTION: AREA = 0.743 ACRES J CN=78 TC = 6.0 MIN. / -- -----___ \ --418417 ra // 415 414 \ 413 v \` / POST -DEVELOPED OFF -SITE ROAD DA: o -\ _ - - _ �44;,• mod. `* / w �� \ // AREA = 0.258 ACRES obra/ 6'csI / CN = 98 ^ b / MATCHLINE SEE SHEETC7.2 �" /� � � ` '440 TC = 6.0 MIN.4�° d'^, �� \ \ o - / ° — POST -DE L PED O F AREA = 4.35 ACRES MIN. IX / — ° / o 0 ° / l / l / I �l /III / / � — \ � _ •-�: ': .. I I \ \ � l I I ��r� // °� 0 07 0 z o°/Z, 07 ° /°0 // lII // l /ell (� r \ c — i I 1 III SCALE 1"=6fL \ / I I I O CRMG W. J. KOTARSKI Lic. No. 0402048507 .�,.02-0�-22, E H w Q DATE 0210712022 DRAWN BY VAN NIEK DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE 1" = 60' a Q Lij z <w LU < z owQ ED <-j o 00 �LU oC o o LU JOB NO. 46883 SHEET NO. C7.3 L Drainage Area A Drainage Area A Land Cover (acres) A Soils B Soils C Soils D Soils Totals Land Cover Rv Forest/Open Space (acres) 0.00 0.00 Managed Turf (acres) 1.91 4.09 6.00 0.18 Impervious Cover (acres) 1.01 7.68 8.69 0.95 Total 14.69 Stormwater Best Management Practices (RR = Runoff Reduction) otal Phosphorus Available for Removal in D.A. A (lb/yr) 21.35 Post Development Treatment Volume in D.A. A (ft) 33,977 --Select from dropdown lists -- Phosphorus Phosphorus UntreatedP Runoff Managed Impervious Volume from Runoff Remaining Total BM Phosphorus Remaining Removal Load from Phosphorus Downstream Practice to be Practice Reduction Turf Credit Cover Credit Upstream Reduction Runoff Treatment Removed By Phosphorus 0 Credit (/o) Area (acres) Area (acres) 3 Practice (ft) s (ft3) a Volume (ft) B Volume (ft) Efficiency Upstream Load to Practice (lb) Load (lb) Employed o (/a) Practices (lb) Practice (lb) 6. Bioretention (RR) 6.a. Bioretention #1 or Micro-Bioretention #1 40 1.35 1.97 0 3,078 4,617 7,696 25 0.00 4.83 2.66 2.17 13.a. Wet Pond #1 or Urban Bioretention (Spec #9) 6.1b. Bioretention #2 or Micro-Bioretention #2 80 0.10 0.25 0 743 186 929 50 0.00 0.58 0.52 0.06 13.a. Wet Pond #1 (Spec #9) 13.a. Wet Pond #1 (Spec 414) TC TOTAL IMPERVIOUS COVER TREATED (ac) 2.22 AREA CHECK: OK. TOTAL MANAGED TURF AREA TREATED (ac) 1.45 AREA CHECK: OK. TOTAL RUNOFF REDUCTION IN D.A. A (ft3) 3,821 TOTAL PHOSPHORUS AVAILABLE FOR REMOVAL IN D.A. A (lb/yr) 21.35 TOTAL PHOSPHORUS REMOVED WITH RUNOFF REDUCTION PRACTICES IN D.A. A (lb/yr) 3.18 TAIL PHOSPHORUS REMAINING AFTER APPLYING RUNOFF REDUCTION PRACTICES IN D.A. A (lb/yr) 18.17 SEE WATER QUALITY COMPLIANCE TAB FOR SITE COMPLIANCE CALCULATIONS 0 1 4.55 1 6.47 1 4,803 1 0 1 30,155 1 30,155 I 50 1 2.23 TOTAL IMPERVIOUS COVER TREATED (ac) 1 8.69 AREA CHECK: OK. TOTAL MANAGED TURF AREA TREATED (ac)l 6.00 1 AREA CHECK: OK. TOTAL PHOSPHORUS REMOVAL REQUIRED ON SITE (lb/yr) 18.07 TOTAL PHOSPHORUS AVAILABLE FOR REMOVAL IN D.A. A (lb/yr) TOTAL PHOSPHORUS REMOVED WITHOUT RUNOFF REDUCTION PRACTICES IN D.A. A (lb/yr) TOTAL PHOSPHORUS REMOVED WITH RUNOFF REDUCTION PRACTICES IN D.A. A (lb/yr) TOTAL PHOSPHORUS LOAD REDUCTION ACHIEVED IN D.A. A (lb/yr) TOTAL PHOSPHORUS REMAINING AFTER APPLYING BMP LOAD REDUCTIONS IN D.A. A (lb/yr) 21.35 9.07 3.18 12.25 9.10 SEE WATER QUALITY COMPLIANCE TAB FOR SITE COMPLIANCE CALCULATIONS NITROGEN REMOVED WITH RUNOFF REDUCTION PRACTICES IN D.A. A (lb/yr) 25.95 NITROGEN REMOVED WITHOUT RUNOFF REDUCTION PRACTICES IN D.A. A (lb/yr) 37.98 TOTAL NITROGEN REMOVED IN D.A. A (lb/yr) 63.93 15.91 1 9.07 1 9.07 Nitrogen Nitrogen Nitrogen Load Untreated Remaining Removal from Upstream Nitrogen Load Removed Nitrogen Efficiency By Practice Practices (Ibs) to Practice (Ibs) Load (Ibs) 0 (/a) (Ibs) 40 0.00 34.55 22.11 12.44 60 0.00 4.17 3.84 0.33 TOTAL RUNOFF REDUCTION IN D.A. A (ft3) 3,821 NITROGEN REMOVED WITH RUNOFF REDUCTION PRACTICES IN D.A. A (lb/yr) 25.95 SEE WATER QUALITY COMPLIANCE TAB FOR SITE CALCULATIONS (Information Only) Site Results (Water Quality Compliance) Area Checks FOREST/OPEN SPACE (ac) IMPERVIOUS COVER (ac) IMPERVIOUS COVER TREATED (ac) MANAGED TURF AREA (ac) MANAGED TURF AREA TREATED (ac) AREA CHECK D.A. A D.A. B D.A. C D.A. D D.A. E AREA CHECK 0.00 0.00 0.00 0.00 0.00 OK. 8.69 1.51 0.00 0.00 0.00 OK. 8.69 1.51 0.00 0.00 0.00 OK. 6.00 0.82 0.00 0.00 0.00 OK. 6.00 0.82 0.00 0.00 0.00 OK. OK. Site Treatment Volume (ft3) 11 40,794 11 Runoff Reduction Volume and TP By Drainage Area RUNOFF REDUCTION VOLUME ACHIEVED (ft3) TP LOAD AVAILABLE FOR REMOVAL (lb/yr) TP LOAD REDUCTION ACHIEVED (lb/yr) TP LOAD REMAINING (Ib/yr) D.A. A D.A. B D.A. C D.A. D D.A. E TOTAL 3,821 2,321 0 0 0 6,143 21.35 3.65 0.00 0.00 0.00 24.99 12.25 2.00 0.00 0.00 0.00 14.26 9.10 1.64 0.00 0.00 0.00 10.74 NITROGEN LOAD REDUCTION ACHIEVED (lb/yr) 63.93 16.67 0.00 0.00 0.00 80.60 Total Phosphorus FINAL POST -DEVELOPMENT TP LOAD (Ib/yr) 25.63 TP LOAD REDUCTION REQUIRED (lb/yr) 18.07 TP LOAD REDUCTION ACHIEVED (lb/yr) 14.26 TP LOAD REMAINING (Ib/yr): 11.38 REMAINING TP LOAD REDUCTION REQUIRED (Ib/yr): 3.82 Total Nitrogen (For Information Purposes) POST -DEVELOPMENT LOAD (lb/yr) 183.36 NITROGEN LOAD REDUCTION ACHIEVED (lb/yr) 80.60 REMAINING POST -DEVELOPMENT NITROGEN LOAD (Ib/yr)j 102.76 j> tP,L1.:IOp U CRAIG W. J. KOTARSKI > Lic. No. 0402048507 :�.02-07-22,?,Q;.. CL O oc f Z O a_ U U Uj W 0 Z O U0 W w H Q DATE 0210712022 DRAWN BY R. VAN NIEKERN DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE N/A zw J I --I a 0 LU w Eo a w O° �I 0 O U Yj L JOB NO. 46883 SHEET NO. C7.4 Drainage Area B Drainage Area A Land Cover (acres) CLEAR BMP AREAS A Soils B Soils C Soils D Soils Totals Land Cover Rv Forest/Open Space (acres) 0.00 0.00 Managed Turf (acres) 0.00 0.82 0.82 0.20 Impervious Cover (acres) 0.00 1.51 1.51 0.95 Total 2.33 Stormwater Best Management Practices (RR = Runoff Reduction) otal Phosphorus Available for Removal in D.A. B (lb/yr) 3.65 Post Development Treatment Volume in D.A. B (ft3) 5,803 --Select from dropdown lists -- Runoff Managed Impervious Volume from Runoff Remaining Total BMP Phosphorus Phosphorus Untreated Phosphorus Remaining Removal Load from Phosphorus Downstream Practice to be Practice Reduction Turf Credit Cover Credit Upstream Reduction Runoff Treatment Removed By Phosphorus 0 Credit (/o) Area (acres) Area (acres) 3 Practice (ft) 3 (ft) 3 Volume (ft) 3 Volume (ft) Efficiency Upstream Load to Practice (lb) Load (lb) Employed % ( ) Practices (lb) Practice (lb) 6.a. Bioretention #1 or Micro-Bioretention #1 40 0.82 1.51 0 2,321 3,482 5,803 25 0.00 3.64 2.00 1.64 or Urban Bioretention (Spec t TC TOTAL IMPERVIOUS COVER TREATED (ac) 1.51 AREA CHECK: OK. TOTAL MANAGED TURF AREA TREATED (ac) 0.82 AREA CHECK: OK. TOTAL RUNOFF REDUCTION IN D.A. B (ft3) 2,321 TOTAL PHOSPHORUS AVAILABLE FOR REMOVAL IN D.A. B (lb/yr) 3.65 TOTAL PHOSPHORUS REMOVED WITH RUNOFF REDUCTION PRACTICES IN D.A. B (lb/yr) 2.00 CHORUS REMAINING AFTER APPLYING RUNOFF REDUCTION PRACTICES IN D.A. B (lb/yr) 1.64 SEE WATER QUALITY COMPLIANCE TAB FOR SITE COMPLIANCE CALCULATIONS STRM STORM SEWER DESIGN COMPUTATIONS STORM FREQUENCY 10 PROJECT: Rio Point LOCATION: COUNTY: Albemarle Designed by: J. Denko Checked by: C. Kotarski UNITS ENGLISH PIPE NO FROM POINT TO POINT DRAIN. AREA "A" Acre (3) RUNOFF COEFF. "C'MENTCA (4) CA TOTAL INLET TIME Minutes (7) RAIN FALL ln/Hr (8) RUNOFF Q CFS (9) INVERT ELEVATIONS LENGTH of Pipe Ft. (12) SLOPE Ft./Ft. (13) SIZE (Dia.Or Span/Rise) In. (14) SHAPE Capacity CFS (15) Friction Slope Ft./Ft. VEL Vn Ft/Sec (16) FLOW TIME Min. (17) REMARKS (18) INCRE-RLCCUMDDTL (5) UPPER END (10) LOWER END (11) REFERENCE STA. REFERENCE (2) STA. 101 102 100 0.000 0.000 0.000 1 2.511 1 2.511 0.000 8.901 22.349 410,736 409.529 120,623 0.010 48.000 Circular 143.659 0.000 8.324 0.242 239 240 238 0.220 0.800 0.176 0.176 0.000 6.000 6.230 1 096 464A69 460.614 177.078 0.020 15.000 Circular 9.913 0.000 5.331 0.554 237 238 236 0.440 0.770 0.339 0.572 0,057 6.554 6.072 3.472 460,510 455.860 172,955 0.027 15.000 Circular 11.471 0.002 8.209 0.351 235 236 234 0.420 0.730 0.307 1.211 0.333 6.905 5.976 7.236 455.760 455.030 73.191 0.010 18.000 Circular 11.362 0.004 6.829 0.179 233 234 232 0A20 0.770 0.323 1.639 0.105 7.083 5.929 9.716 454.930 452.955 197.497 0.010 24.000 Circular 24.505 0.002 7.364 0.447 231 232 230 O. 190 0.380 0.072 1.816 0.105 6.400 6.115 11.101 452.860 450.870 75.538 0.026 24.000 Circular 39.773 0.002 10.872 0.116 229 230 228 0.490 0.700 0.343 2.263 0.105 6.516 6.082 13.764 450,781 450.000 78.068 0.010 24.000 Circular 24.505 0.003 8.043 0.162 227 228 226 0.200 0.870 0.174 2.437 0.000 6.678 6.038 14.714 449.900 447.500 92.375 0.026 30.000 Circular 71.620 0.001 11.501 0.134 243 244 242 0.270 0.480 O. 130 0.130 0.000 6.000 6.230 0.807 460.000 45T774 111.286 0.020 15.000 Circular 9.894 0.000 4.867 0.381 241 242 226 0.300 0.430 0.129 0.316 0.057 6.381 6.120 1.931 457.670 456.080 73.507 0.022 15.000 Circular 10.288 0.001 6.443 0.190 225 226 224 0.180 0.900 0.162 2.915 0.000 6.811 6.001 1T491 447068 439.636 77.320 0.096 30.000 Circular 13Z749 0.002 19273 0.067 257 258 256 0.000 0.000 0000 0.240 0.240 6.000 6.230 1.497 451.439 450.870 56.921 0.010 15.000 Circular 6.996 0.000 4.547 0209. 255 2_5 6 25_ 0 0.240 0.740 0.178 0.418 0.000 6.209 6.169 5 2.-78 450.771 s s 4. 03_ .0 142.07s_ 0.010 15.000 Circular 1 6.996 1 0.001 5.280 10.133 253 254 252 0.000 0.000 0.000 1.176 1.176 6.000 6.230 7.327 453,366 451.060 115.282 0.020 19.000 Circular 16.090 0.004 8.911 0.216 251 252 250 0.000 0.000 0.000 1.176 0.000 6.216 6.167 2253 450.958 449.600 84.479 0.016 18 000 Circular 14.425 0.004 8.192 0.172 249 250 224 0.000 0.000 0.000 1.784 0.190 6.387 6.118 10.915 449.500 432.174 128.821 0134 18.000 Circular 41.725 0.009 19.918 0.108 223 224 202 0.000 0.000 0.000 4.699 0.000 6.878 5.983 28.113 431.424 418.421 58.371 0.223 36.000 Circular 341.034 0.002 29.207 0.033 219 220 218 0.330 0.760 0.251 0.251 0.000 6.000 6.230 L563 464.000 460.700 206,104 0.016 15.000 Circular 8.853 0.000 5A47 0.631 217 218 216 0.510 0.760 0.388 0.638 0.000 6.631 6.050 3.863 460,800 456.700 191.781 0.021 15.000 Circular 10.229 0.003 7.770 0.411 215 216 214 0.250 0.940 0.210 0.848 0.000 7.042 5.940 5.039 456,600 456.300 25.456 0.012 15.000 Circular 7.595 0.005 6,634 0.064 213 214 212 0.380 0.790 0.300 1.149 0.000 7.106 5.923 6.803 456,200 453.859 234.116 0.010 18 000 Circular 11.377 0.004 6.739 0.579 211 212 210 0.080 0820 0.066 1329 0.114 7.685 5.775 2671 453,760 452,443 131.675 Q070 18.000 Circular 11.377 0.005 6.926 0.317 209 210 208 0.360 0.650 0.234 1.676 0.114 8.002 5.698 9.552 452.443 451.275 116.823 0.010 24.000 Circular 24.505 0.002 7.331 0.266 207 208 206 0.290 0.780 0.226 1.902 0.000 8.267 5.636 10.721 451.180 450,707 47.255 0.010 24.000 Circular 24.505 0.002 7.556 0.104 221 222 206 0.110 0.790 0.087 0.087 0.000 0.000 8.901 0.773 454.004 453.004 53.253 0.019 15.000 Circular 9.587 0.000 4.701 0.189 205 206 204 0.000 0.000 0.000 1.989 0.000 8.372 5.611 11.163 442.337 436.290 40.312 0.150 24.000 Circular 94.906 0.002 20.293 0.033 247 248 246 0.000 0.000 0.000 0.722 0.722 6.000 6.230 4.498 439,500 438.873 125.318 0.005 15.000 Circular 4.947 0.004 4.580 0.456 245 246 204 0.000 0.000 0000 0.722 0.000 6.456 6.099 4A03 438.770 438. 143 125.301 0.005 15.000 Circular 4.947 0.004 4.567 0.457 203 204 202 0250 0.880 0.220 2.931 0.000 8.405 5.604 16A27 435.790 419.303 393.559 0.042 30.000 Circular 90.943 0.001 14.080 0.466 201 1 202 200 0.000 0.000 0.000 7.630 0.000 8.871 5.499 41.956 1 418.421 413.596 59.012 0.082 36.000 Circular 206.609 0.003 22.964 0.043 301 302 300 10+00.00 O 180 0.900 0.162 0.162 0.000 0.000 8.901 1.442 439.240 413.000 174.935 O 150 15.000 Circular 2T096 0.000 11.747 0.248 405 406 404 0.340 0.830 0.282 0.282 0.000 1 0.000 8.901 1 2.512 461.410 1 460.726 136.760 1 0.005 1 15.000 Circular 4.947 0.001 1 4.056 0.562 403 404 1 402 1 0.000 0.000 0.000 0.396 1 0.114 1 0.562 8.538 1 3.383 1 460.630 1 459.858 1 154.416 0.005 15.000 Circular 1 4.947 0.002 4.350 0.592 401 402 1 400 0.130 0.680 0.088 0.485 1 0.000 1 1.154 8.192 1 3.970 1 459.760 1 459.501 1 37.707 1 0.007 15.000 Circular 1 5.797 0.003 5.099 0.123 503 504 502 0.170 0.800 0.136 0.136 1 0.000 1 0.000 8.901 1 1.211 1 456.885 1 456.290 1 100.461 0.006 15.000 Circular 1 5.385 1 0.000 3.548 0.472 501 502 500 0.180 0.860 0155 0.291 1 0.000 1 0.472 8.594 1 2.499 1 456.190 1 456.026 1 37.362 0.004 15.000 Circular 4.637 1 0.001 3.858 0.161 601 602 600 0.390 0A80 0.187 0.187 0.000 1 0.000 8.901 1 1.666 459.772 459.500 1 54.397 0.005 15,000 Circular 4.947 1 0.001 3.644 0.249 701 702 700 0.000 0.000 0.000 2.038 2.038 1 0.000 8.901 1 18.138 441.500 439.500 1 35.358 0.057 18.000 Circular 27.059 1 0.025 16.450 0.036 809 810 808 0.280 0.900 0.252 0.252 0.000 0.000 8.901 2.243 449.000 448A75 26.248 0.020 15 000 Circular 9.894 0.001 6.535 0.067 807 808 802 0.000 0.000 0.000 0.252 0.000 0.067 8.856 2.232 448.380 446.430 170.811 0.011 15.000 Circular 7.475 0.001 5.329 0.534 805 806 804 0.000 0.000 0.000 0.000 0.000 0.000 8901 0.000 462.421 455.600 327.046 0.021 15.000 Circular 10.104 0.000 0.000 0.000 803 804 802 0.190 0.840 0.160 0.160 0.000 0.000 8.901 1.421 455,498 446.430 315.199 0.029 15.000 Circular 11.866 0.000 6.530 0.805 801 802 800 0A30 0.840 0.361 1.210 0.437 0.805 8.392 10.153 446328 446.000 16.385 0.020 18.000 Circular 16.090 0.008 9.650 0.028 STRM HYDRAULIC GRADE LINE ANALYSIS INCIDENCE PROBABILITY 10 Year Nitrogen Nitrogen Load Untreated Nitrogen Remaining Removal from Upstream Nitrogen Load Removed Nitrogen Efficiency Practices (Ibs) to Practice (Ibs) By Practice Load (Ibs) a/ ( ) (Ibs) M, UST1,11:43 40 0.00 26.05 16.67 9.38 TOTAL RUNOFF REDUCTION IN D.A. B (ft3) 2,321 NITROGEN REMOVED WITH RUNOFF REDUCTION PRACTICES IN D.A. B (lb/yr) 16.67 SEE WATER QUALITY COMPLIANCE TAB FOR SITE CALCULATIONS (Information Only) PROJECT: Rio Point DESIGNED BY: J. Denko Checked: C. Kotarski INLET INLET OUTLET WATER DIA. PIPE DESIGN DSCH. LB4GTH RPE FRICTION SLOPE, Sfo FRICTION LOSS JUNCTION LOSS FlNAL Inlet Water Rim Corrments 1.3 0.5 OR STATION SURFACE Do Qo Lo Hf Vo Ho Qi Vi QiVi Vi'2/2g Hi Angle HA Ht R Ht H Surface Bev JUNCTION ELEV. (In) (CFS) (Ft) (FT/FT) (Ft) (Ft) (Ft) Elevation 102 414.2 48 22.35 120.62 0.02% 0.03 8.32 0.27 1 0 0 0 1 0 0 0 0 0.27 0 TRUE 0.16 414.36 418 OK -3.64 202 416 36 41.96 59.01 0.34% 0.2 22.96 2.05 28.11 29.21 821.09 13.25 4.64 90 2.15 8.84 0 TRUE 9.04 425.03 429.07 OK -4.04 224 422.78 36 28.11 58.37 0.15% 0.09 29.21 3.31 17.49 19.27 337.1 5.77 2.02 79.74 4.07 9.4 0 TRUE 4.79 427.57 448.2 OK -20.63 226 441.64 30 17.49 77.32 0.15% 0.12 19.27 1.44 14.71 11.5 169.22 2.05 0.72 35.39 0.88 3.04 0 TRUE 1.64 443.28 461.28 OK -18 228 449.5 30 14.71 92.38 0 0.11 !0 0.1 11.5 0.51 13.76 8.04 110.71 1 0.35 70.32 0.61 1.48 0 TRUE 0.84 450.34 460.92 OK -10.58 230 451.6 24 13.76 78.07 0.32% 0.25 8.04 0.25 11.1 10.87 120.69 1.84 0.64 68.49 1.12 2.01 0 TRUE 1.25 452.85 460.5 OK -7.65 232 452.85 24 11.1 75.54 0.21% 0.15 10.87 0.46 9.72 7.36 71.55 0.84 0.29 91.83 0.59 1.34 0 TRUE 0.83 453.68 460.32 OK -6.64 234 454.56 1 24 1 9.72 197.5 1 0.16% 0.31 7.36 0.21 7.24 6.83 1 49.42 0.72 1 0.25 1 83.67 0.48 0.94 0 TRUE 0.78 1 455.34 462.36 OK -7.02 236 456.23 18 7.24 73.19 0.40% 0.3 1 6.83 0.18 3.47 8.21 28.5 1.05 0.37 6.33 0.06 0.61 0.79 TRUE 0.69 456.92 463.41 OK -6.49 238 456.92 15 3.47 172.95 0.25% 0.43 8.21 0.26 1.1 5.33 5.85 0.44 0.15 22.51 0.13 0.55 0.71 TRUE 0.78 457.7 465.53 OK -7.83 240 461.61 15 1.1 177.08 0.02% 0.04 5.33 0.11 0 0 0 0 0 0 0 0.11 0.14 TRUE 0.12 461.73 468.84 OK -7.11 204 425.03 30 16.43 393.56 0.14% 0.54 14.08 0.77 11.16 20.29 226.53 6.39 2.24 91.59 4.48 7.48 0 FALSE 8.02 433.06 443.39 OK -10.33 206 437.89 24 11.16 40.31 0.21% 0.08 20.29 1.6 10.72 7.56 81.01 0.89 0.31 46.75 0.44 2.35 0 TRUE 1.26 439.15 458.47 OK -19.32 208 452.31 24 10.72 1 47.25 0.19% 0.09 7.56 0.22 9.55 1 7.33 70.02 0.83 1 0.29 41.2 0.36 0.87 0 TRUE 1 0.53 452.83 459.11 1 OK -6.27 210 452.88 24 9.55 116.82 0 0.15/0 0.18 7.33 0.21 7.67 6.93 53.13 0.74 0.26 0 0 0.47 0 TRUE 1 0.41 453.29 459.98 OK -6.69 212 453.64 18 7.67 131.67 0.45% 0.6 6.93 0.19 6.8 6.74 45.84 0.71 0.25 0.96 0 0.43 0 TRUE 0.81 454.46 461.42 OK -6.96 214 455.06 18 6.8 234.12 0.36/0 0.84 6.74 0.18 5.04 6.63 33.43 0.68 0.24 44.04 0.29 0.71 0.92 TRUE 1.3 456.36 460.51 OK -4.16 216 457.3 15 5.04 25.46 0.52% 0.13 6.63 0.17 3.86 7.77 30.01 0.94 0.33 45 0.47 0.97 1.26 TRUE 0.76 458.06 460.96 OK -2.9 218 458.06 15 3.86 191.78 0.30% 0.58 7.77 0.23 1.56 5.45 8.51 0.46 0.16 0 0 0.4 0.51 TRUE 0.84 458.9 464.97 OK -6.07 220 461.7 15 1.56 206.1 0.05% 0.1 5.45 0.12 0 0 0 0 0 0 0 0.12 0.15 TRUE 0.18 461.88 46T98 OK -6.1 246 439.14 15 4.4 125.3 0.40 0 0.5 4.57 0.08 4.5 4.58 20.6 0.33 0.11 55.59 0.18 0.38 0 TRUE 0.68 439.83 445.15 OK -5.32 248 439.87 15 4.5 125.32 0.41% 0.52 4.58 0.08 0 0 0 0 0 0 0 0.08 0 TRUE 0.56 440.43 444 OK -3.57 222 454 15 0.77 53.25 0.01% 0.01 4.7 0.09 0 0 0 0 0 0 0 0.09 0.11 TRUE 0.06 454.07 459.04 OK -4.97 250 433.37 18 10.92 128.82 0.92% 1.19 19.92 1.54 7.25 8.19 59.42 1.04 0.36 91.86 0.73 2.63 0 TRUE 2.5 435.88 456 OK -20.12 256 451.35 15 2.58 42.08 0.14% 0.06 5.28 0.11 1.5 4.55 6.81 0.32 0.11 31.86 0.11 0.33 0.43 TRUE 0.27 451.62 459.54 OK -7.91 258 451.87 15 1.5 56.92 0.05% 0.03 4.55 0.08 0 0 1 0 0 0 0 0 0.08 0 TRUE 0.07 451.94 1 456 OK -4.06 252 450.8 18 7.25 84.48 0.41% 0.34 8.19 0.26 7.33 8.91 65.3 1.23 0.43 81.27 0.81 1.51 0 TRUE 1.1 451.9 462.52 OK -10.62 254 452.26 18 7.33 115.28 0.41% 0.48 8.91 0.31 0 0 0 0 0 0 0 0.31 0 TRUE 0.63 452.89 461 OK -8.11 242 457.08 15 1.93 73.51 0.08% 0.06 6.44 0.16 0.81 4.87 3.93 0.37 0.13 32.47 0.13 0.42 0.54 TRUE 0.33 457.41 462.73 OK -5.32 244 458.77 15 0.81 111.29 0.01% 0.01 4.87 0.09 0 0 0 0 0 0 0 0.09 0.12 TRUE 0.07 458.85 464.06 OK -5.21 402 461.26 1 15 1 3.97 137.71 1 0.32% 1 0.12 5.1 0.1 3.38 4.35 1 14.71 0.29 0.1 66.9 1 0.18 0.38 0 1 TRUE 0.31 1 461.57 464.26 OK -2.69 404 461.57 1 15 1 3.38 1154.421 0.23% 1 0.36 1 4.35 0.07 1 2.51 4.06 1 10.19 0.26 0.09 63.79 1 0.14 0.31 0 1 TRUE 0.51 1 462.09 466.67 OK -4.58 406 462.09 1 15 1 2.51 1136.761 0.13% 1 0.18 1 4.06 1 0.06 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0.06 1 0.08 1 TRUE 1 0.22 1 462.3 1 465.26 1 OK -2.96 502 457.03 1 15 1 2.5 1 37.36 1 0.13% 1 0.05 1 3.86 1 0.06 1 1.21 1 3.55 1 4.3 1 0.2 1 0.07 1 76.13 1 0.13 1 0.26 1 0.33 1 TRUE 1 0.21 1 457.24 1 460.85 1 OK -3.61 504 457.29 1 15 1 1.21 1100.461 0.03% 1 0.03 1 3.55 1 0.05 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0.05 1 0.06 1 TRUE 1 0.06 1 457.35 1 462.77 1 OK -5.42 702 440.7 1 18 1 18.14 135.36 1 2.54% 1 0.9 1 16.45 1 1.05 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1.05 1 0 1 TRUE 1 1.42 1 442.12 1 446 1 OK -3.88 802 448 1 18 10.15 1 16.38 1 0.80% 0.13 1 9.65 0.36 1 2.23 5.33 1 11.89 0.44 1 0.15 79.66 1 0.44 1 0.95 1.24 TRUE 0.75 1 448.75 451.69 1 OK -2.94 808 448.75 1 15 1 2.23 1170.811 0.10% 1 0.17 1 5.33 1 0.11 1 2.24 1 6.54 1 14.66 0.66 1 0.23 39.21 1 0.29 1 0.63 1 0 TRUE 0.49 1 449.24 455.67 1 OK -6.44 810 449.48 1 15 1 2.24 126.25 1 0.10% 1 0.03 1 6.54 1 0.17 1 0 1 0 1 0 0 1 0 0 1 0 1 0.17 1 0.22 TRUE 0.13 1 449.61 453.12 1 OK -3.51 804 448.75 1 15 1.42 315.2 0.04% 0.13 6.53 0.17 0 0 0 0 0 0 0 0.17 0.22 TRUE 0.24 448.99 466.71 OK -17.72 806 1 1 456.E 1 15 1 0 1327.051 0.00% 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 TRUE 1 0 1 456.6 1 466.91 1 OK -10.31 !A�c'.�G CRAIG W. J. KOTARSKI Lic. No. 0402048507 .�,.02-0-1-22, M E 0 0 M u N N Q 0 > E w °i E Uj a2 3 U o LL K O L GJUrnq W J -N LU d N N N Z H B X �i ix 6 04 =� _ N = U > � Q ui c a, O N � M W J UJ � Uri 0 0 x c� ce x 0 w w_ x U z O M 0 0 r f E H w H Q 0 DATE 0210712022 DRAWN BY R. VAN NIEKERI DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE N/A > zwL H� Q OLu w ^ m LL Q LL O O z O U Q J U J U Lij C: G IY 0 JOB NO. 46883 L SHEET NO. C7.5 SITE OUTFALL PEAK FLOW ANALYSIS DRAINAGE AREA NAME TOTAL AREA (AC) TIC (MIN) CN PEAK FLOW RATE (CFS) IYR 10YR RUNOFF VOLUME (AC -FT) Pre Developed Onsite Drainage Area 1 10.67 9.1 56 1.57 20.57 OA66 3.89 6.8 61 1.82 11.06 0.104 Pre Developed Onsite Drainage Area 2 3.88 6.4 57 0.87 9.97 0.068 Pre Developed Onsite Drainage Area 3 4.35 6.4 60 1.78 11.90 0.106 Pre Developed Offsite Drainage Area - Rio Commons 0.26 6.0 98 1.07 1.98 0.056 Pre Developed Offsite Drainage Area - Road COMBINED PRE DEVELOPMENT FLOW 5.65 51.69 0.44 Post Developed Onsite Drainage Area 1A Post Developed Onsite Drainage Area 1B Post Developed Onsite Drainage Area 1C Post Developed Onsite Drainage Area 1D Post Developed Onsite Drainage Area 1E Post Developed Onsite Drainage Area 2 Post Developed Onsite Drainage Area 3 Offsite area to pond Rio Commons Pre Developed Offsite Drainage Area - Road COMBINED POST DEVELOPMENT FI RISER TOP ELEV. 422.00 ELEV. 417.00 ELEV. 410.74 1.16 6.0 87 3.48 7.72 0.17 0.35 6.0 87 1.04 2.31 0.051 1.42 9.4 83 3.23 7.87 0.174 0.74 6.0 78 1.49 4.02 0.071 11.03 9.4 79 20.60 55.40 1.112 2.33 8.7 85 5.98 13.89 0.313 1.42 6.3 55 0.18 2.90 0.024 4.35 6.0 74 6.92 20.91 0.336 0.26 &0 98 1.07 1.98 0.056 OW 1.35 28.20 2.30 DI-1 RISER STRUCTURE 102 DETAIL No Scale !..........1 ,. to Of 40 Mill E� 4r44444..4! '•�'� .�.4444.444!1 OK OK 100 YR WSE 423.98 10 YR WSE 422.56 _1YRWSE 421.07 DIA ORIFICE _EV. 417.00 48" DIA CULVERT ELEV. 410.74 ' SUMP 3'XT AGAINST NDER ORIFICE FOR DEBRIS SEDIMENT AND CLEAN OUT. /1fi' HOLES AS SHOWN k7EM (TYP.) -1 1/2' X 1 1/2" X 1/4" STEEL ANGLE (TIP.) 1 1/2" X 1/4- STEEL STOCK WELDED TO BASE AS SHOWN GENERAL NOTES FOR TRASH RACK 1. STEEL TO CONFORM TO ASTM A-36. 2. ALL SURFACES OF TRASH RACK(S) MUST BE HOT DIPPED GALVANIZED AFTER FABRICATION. 3. TRASH RACK(S) TO BE FASTENED TO WALL WITH 1/2" MASONRY ANCHORS. TRASH RACK(S) TO BE REMOVABLE. 4. TRASH RACK(S) TO BE CENTERED HORIZONTALLY OVER THE OPENING. 5. FABRICATOR MAY MODIFY COMPONENTS OF TRASH RACK FRAME TO IMPROVE CONSTRUCTABILITY OF TRASH RACK. MODIFICATIONS MUST BE APPROVED BY MCDPS PRIOR TO FABRICATION. ORIFICE TRASH RACK DETAIL DETAIL TAKEN FROM MONTGOMERY COUNTY, MD WATER RESOURCES SPECIFICATIONS POST FLOW ENERGY BALANCE ALLOWED PER ENERGY IMPROVEMENT BALANCE* FACTOR (CFS) 0.800 1.94 CHANNEL PROTECTION (ENERGY BALANCE) -1 YR Ql YR POST-DEV TOTAL G IF * (Ql YR PRE-DEV * RV, YR PRE-DEV)/RV 1YR POST -DEV + Ql YR OFFSITE 1.35 CFS <- 0.800 * ( 5.65 * 0.44 ) / 2.30 + 1.07 1.35 CFS <- 1.94 CFS OK FLOOD PROTECTION- 10 YR Q10 YR POST-DEV TOTAL = Ql0 YR PRE-DEV 28.20 CFS <- 51.69 CFS 28.20 CFS < 51.69 CFS OK Table 14.6. Tvoical Wet Pond Maintenance Tasks and Frequencv Maintenance Items' Frequency' • Remove debris and blockages Quarterly or after major storms • Repair undercut, eroded, and bare soil areas (>1 inch of rainfall) • Mowing embankment Twice a year • Shoreline cleanup to remove trash, debris and floatables • A full maintenance inspection Annually • Open up the riser to access and test the valves • Repair broken mechanical components, if needed • Pond buffer and aquatic bench reinforcement plantings One time -during the second year followin construction • Forebay Sediment Removal Every 5 to 7 years • Repair pipes, the riser andspillway, as needed From 5 to 25 years 'Maintenance items and required frequency should be verified with local requirements CONVERSION FROM SEDIMENT BASIN TO WET POND: • CONVERT SEDIMENT BASIN TO WET POND ONLY AFTER ALL UPSTREAM DRAINAGE AREAS HAVE BEEN STABILIZED • FLUSH AND CLEAR ALL ON -SITE PAVING AND STORM DRAIN PIPE OF ANY SEDIMENTS • DE -WATER AND DREDGE BASIN • RE -GRADE AREAS TO ACHIEVE FINAL PROPOSED ELEVATIONS • REPAIR/CLEAN ALL RIP RAP OUTFLOW PROTECTION AREAS TO BE FREE AND CLEAR OF SEDIMENT Is CONVERT RISER STRUCTURE FROM SEDIMENT BASIN DESIGN TO FINAL POND RISER DESIGN COMPACTION TESTS SHOULD BE PERFORMED REGULARLY THROUGHOUT THE EMBANKMENT CONSTRUCTION. • TYPICALLY, ONE TEST PER 5,000 SQ. FT. ON EACH LAYER OF FILL OR AS DIRECTED BY THE GEOTECHNICAL ENGINEER. • USE EITHER A STANDARD PROCTOR TEST (ASTM D698) OR A MODIFIED PROCTOR TEST (ASTM D1557 - USUALLY MORE APPROPRIATE FOR EARTHEN DAMS). • ANEW PROCTOR TESTIS REQUIRED IF THE MATERIAL CHANGES FROM THAT PREVIOUSLY TESTED. • THE ENGINEER SHOULD CERTIFY, AT THE TIME OF CONSTRUCTION, THAT EACH FILL LAYER MEETS THE MINIMUM DENSITY. A GEOTECHNICAL OR CONSTRUCTION INSPECTOR SHOULD BE ON SITE DURING EMBANKMENT CONSTRUCTION TO DO THE FOLLOWING: • TEST FILL COMPACTION • OBSERVE FOUNDATION PREPARATION. • OBSERVE PIPE INSTALLATION. • OBSERVE RISER CONSTRUCTION. • OBSERVE FILTER INSTALLATION, ETC. 2.03' IK;7 100-YR ELEV. 423.98 CREST ELEV. 422.00' STIR NUMBER: 102 DI-1 RISER W/ ANTI -VORTEX DEVICE INV OUT 410.74' (48" RCP) 3" ORIFICE W1 TRASHRACK 417.00' PERMANENT POOL ELEV. 417.00' POND BOTTOM 413.00' V DIA. X 1.5' CONC. BASE TOP OF DAM = 426.00 �8'� PIPE NUMBER: 101 48" OUTLET PIPE BED j5" IN CONCRETE NOTES: 1. TRASH RACK TO BE INSTALLED ON 3" ORIFICE AS SHOWN ON DETAIL ON THIS SHEET OR APPROVED EQUAL. 2. IMPERVIOUS CORE AND CUTOFF TRENCH SHOWN FOR INFORMATIONAL PURPOSES ONLY. FINAL DESIGN TO BE PROVIDED BY GEOTECHNICAL ENGINEER. 3. WARNING SIGNS PROHIBITING SWIMMING MUST BE POSTED 4. AQUATIC AND SAFETY BENCHES ARE NOT REQUIRED FOR PONDS WITH DEPTHS <4' 5. POND EMBANKMENT TO BE STABILIZED WITH TURF. NO OTHER PLANTINGS ARE PROPOSED WITHIN POND FOOTPRINT. WATER QUALITY VOLUME WQV REQUIRED: 23,158 CIF WET STORAGE VOLUME PROVIDED: 27,179 CIF IMPERVIOUS CORE AND CUTOFF TRENCH 1-YR ELEV = 421.07 10-YR ELEV = 422.56 100-YR ELEV = 423.98 ■�■�■�■�■ l "Tomorrow' Natural Resources Today' Chesapeake Bay Nutrient Land Trust, LLC. January 7, 2022 l Timmons Group ATTN: Jessica Denko, P.E. n 608 Preston Avenue, Suite 200 Charlottesville, VA 22903 RE: CBNLT/Reynolds Farm Nutrient Facility - Nutrient Credit Availability Project Reference: Rio Point, Albemarle County Dear Ms. Denko, This letter is to confirm the availability of authorized nutrient credits sufficient to meet your project requirements at our Reynolds Farm nutrient facility, which is registered with the Virginia Department of Environmental Quality (DEQ). These nutrient credits are generated and managed under the terms of the Reynolds Farm Nutrient Reduction Implementation Plan dated October 16, 2019 which was authorized by VADEQ on December 1, 2020. The Reynolds Farm project has been authorized to provide nutrient credits for use in the James River watershed including HUCs 02080201, 02080202, 02080203, 02080204, 02080205 and 02080207. These credits are transferable to those entities regulated under DEQ's Stormwater Management Program in accordance with VA Code § 62.1-44.15:35. Currently the Reynolds Farm facility has 133.11 pounds of phosphorus credits available and will be able to meet the phosphorus removal requirement for your project. If we can provide further assistance please feel free to contact our office. Sincerely, Chesapeake Bay Nutrient Land Trust, LLC By Its Manager EarthSource Solutions, Inc. ScottA. Reed. �(b Scott A. Reed Vice President eel_ Chesapeake Bay Nutrient Land Trust, LLC. • 5735 S. Laburnum Avenues-!TRichmond,.VA 23231� to, i!'2�uyww.c n Lcom FOREBAY BOTTOM 413.00' FOREBAY CROSS SECTION DETAIL STIR NUMBER: 100 ES-1 U CRATG W. J. KOTARSKI Lic. No. OQ2048507 m E CD N OV N C > E w ° E a `V :: R: M. U. o^ K O L Q J U W W J -N H d N N N v Z H Y x < 0a =� U W N = U > � .n c a, O N v M a� W J E Z O !L K U In DJ 0 Z O UO 5 W Of w DATE 0210712022 DRAWN BY VAN NIEK DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE N/A CO Z O Q J zw� ~ Z U J O w Q ^ LL m Q ( LL UJ 0 U �G�/ L.I_ O U) LEVEL 1 WET POND No Scale L H 10B NO. 46883 SHEET NO. C7.6 NYLOPLAST BASIN CLEANOUT WITH DOME GRATE RAMP SOIL TO LIP OF OVERFLOW STRUCTURE MIN SLOPE 3:1 BOTTOM OF BIORETENTION BASIN 3" HARDWOOD BARK MULCH BOTTOM ELEV VARIES 36" BIOFILTER MIX BOTTOM ELEV VARIES 3" NO. 8 STONE TOP ELEV VARIES 15" NO. 57 STONE ELEV. VARIES SEE CLEANOUT DETAIL SHEET C1.1 SCHEDULE40 MIRAFI 140N FILTER PVC UNDERDRAIN FABRIC OR EQUIVALENT. TIE INTO OVERFLOW TO BE 2' WIDE STRUCTURE CENTERED ON UNDERDRAIN NOTES 1. 36" BIOFILTER MEDIA DEPTH SHALL BE THE MINIMUM DEPTH AFTER A SETTLING PERIOD OF THREE DAYS. 2. APPROXIMATE GROUND WATER ELEVATION IS 399.5' PROVIDING MORE THAN 2' OF SEPARATION FROM THE BOTTOM OF THE BIORETENTION 3. BEDROCK WAS NOT ENCOUNTERED IN NEARBY BORE HOLES WITHIN 18' OF BOTTOM OF BIORETENTION 4. FILTER MEDIA MUST BE SUPPLIED BY A VENDOR LEVEL 2 BIORETENTION ALONG UNDERDRAIN NO SCALE BMP PRACTICE DOCUMENTATION NOTE: CONTRACTOR SHALL NOTIFY THE TIMMONS GROUP PRIOR TO COMMENCEMENT OF CONSTRUCTION OF BMP PRACTICES INCLUDING THE BIORETENTION FILTERS AND THE WET POND. A SPECIFIC PRECONSTRUCTION MEETING BETWEEN THE CONTRACTOR, ENGINEER, INSPECTOR, AND MANUFACTURER IS HIGHLY RECOMMENDED PRIOR TO INSTALLATION OF THESE PRACTICES TO ENSURE THESE PRACTICES ARE NOT ONLY INSTALLED CORRECTLY BUT ALSO DOCUMENTED THROUGHOUT CONSTRUCTION. IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO DOCUMENT THE INSTALLATION OF THESE PRACTICES AND IF THEY PROCEED WITH DOING SO IT IS DONE AT THEIR OWN RISK. CONTRACTOR SHALL TAKE NOTES, PICTURES, AND MEASUREMENTS OF ALL STRATA LAYERS WITHIN THE BIORETENTION FACILITIES DURING CONSTRUCTION. IT IS HIGHLY RECOMMENDED TO TAKE PICTURES OF EACH MEASUREMENT OF EACH STRATA LAYER OF EACH FACILITY. WITHOUT DOCUMENTING TO THIS LEVEL OF DETAIL THE CONTRACTOR RUNS THE RISK OF DIGGING THE FACILITIES BACK UP TO PROVE THE CORRECT SECTIONS WERE INSTALLED. TOP ELEV. 3' (SEE PLAN SHEETS) �� TYPE 304 STAINLESS STEEL WIRE MESH FOREBAY BOTTOM (SLOPE VARIES) GROUT IN GABION WALL ADJACENT TO FOREBAY & POND BOTTOM POND/BIORETENTION BOTTOM (SLOPE VARIES) GABION BASKET NOTES: 1. INSTALL GABIONS IN ACCORDANCE WMANUFACTURER'S SPECIFICATIONS. 2. GABION BASKETS MUST MEET ASTM A974-97. 3. GABION BASKET WIRE MESH MUST BE TYPE 304 STAINLESS STEEL GAUGE 11 OR LOWER. 4. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR APPROVAL PRIOR TO INSTALLATION. 5. FILL GABION BASKETS w/ 4• TO 8" STONE (Din = 6•). GABION BASKET FOREBAY DETAIL NOT TO SCALE 3" HARDWOOD BARK MULCH BOTTOM ELEV VARIES 36" BIOFILTER MIX BOTTOM ELEV VARIES 3" NO. 8 STONE TOP ELEV VARIES 15" NO. 57 STONE SCHEDULE40 PVC UNDERDRAIN TIE INTO OVERFLOW STRUCTURE LEVEL 2 BIORETENTION CROSS SECTION NO SCALE ELEV. VARIES MIRAFI 140N FILTER FABRIC OR EQUIVALENT. TO BE 2' WIDE CENTERED ON UNDERDRAIN GEOTEXTILE TO MEET TABLE 9.6 OF THE BIORETENTION MATERIAL SPECIFICATIONS FOR GEOTEXTILE/LINERS Bioretention Elevation Information Bioretention Number 1A 1B 1C 1D lE 2A Top embankment 447 458 461.5 450 457 448 Top of Mulch Elevation 443.75 456 459.5 448 456 446 3" mulch 443.5 455.75 459.25 447.75 455.75 445.75 Mediafilter-3' 440.5 452.75 456.25 444.75 452.75 442.75 Stone layer 439.25 451.5 455 443.5 451.5 441.5 invert out 439.25 1 451.5 1 455 443.5 451.5 1 441.5 RIMelev 1 444.5 1 456.5 1 460 1 448.5 1 456.5 1 446.5 PIP7:*i�� 2'MIN ED GRADE ASLOPE OR EQUIVALENT PRETREATMENT - GRAVEL DIAPHRAGM No Scale VA DCR SPECIFICATION NO. 9 SOIL MEDIA SPECIFICATIONS VA DCR STORMWATER DESIGN SPECIFICATION NO. 9 BIORETENTION Soil porosity is the fraction of a volume of soil material that is not solid, also referred to as the void space. As the volume of fines, defined as either clay particles (less than 2 microns, or 0.002 min) or silt particles (between 2 and 50 microns, or 0.002 and 0.05 min) within a given soil mix Table 9.7. Bioretention Material Specifications is increased, there is a possibility that those fines may be flushed or migrate downward through Material Specification Notes Filter Media Filter Media to contain: • 80% - 90% sand The volume of filter media based on 110% Composition • 10%-20% soil fines of the plan volume, to account for settling 3%-5% organic matter or compaction. Available P between L+ and M per Filter Media DCR 2005 Nutrient Management The media should be certified by the Testing Criteria. supplier. Mulch Layer Use aged, shredded hardwood bark Lay a 2 to 3 inch layer on the surface of the mulch or stable coarse compost. filter bed. Alternative Use river stone or pea gravel, coir and Lay a 2 to 3 inch layer of to suppress weed Surface Cover jute matting, or turf cover. growth. Loamy sand or sandy loam texture, Top Soil with less than 5% clay content, pH 3 inch surface depth. For Turf Cover corrected to between 6 and 7, and an organic matter content of at least 2%. Use a non -woven geotextile fabric with Apply only to the sides and directly above Geotextile/Liner a flow rate of > 110 gal./min./sq. ft. the underdrain. For hotspots and certain (e.g., Geotex 351 or equivalent) karst sites only, use an appropriate liner on bottom. Choking Layer Lay a 2 to 4 inch layer of sand over a 2 inch layer of choker stone (typically #8 or #89 washed gravel), which is laid over the underdrain stone. Stone Jacket for Underdrain 1 inch stone should be double -washed 12 inches for the underdrain; and/or Storage and clean and free of all fines (e.g., 12 to 18 inches for the stone storage layer, Layer VDOT #57 stone). if needed Use 6 inch rigid schedule 40 PVC pipe Lay the perforated pipe under the length of Underdrains, (or equivalent corrugated HDPE for the bioretention cell, and install non- Cleanouts, and micro-bioretention), With 3/8-inch perforated pipe as needed to connect With Observation perforations at 6 inches on center; the storm drain system. Install T's and Y's Wells position each underdrain on a 1% or as needed, depending on the underdrain 2% slope located nor more than 20 feet configuration. Extend cleanout pipes to the from the next pipe. surface with vented caps at the Ts and Ys. Plant one tree per 250 square feet (15 Establish plant materials as specified in the feet on -center, minimum 1 inch landscaping plan and the recommended caliper). plant list. Shrubs a minimum of 30 inches high In general, plant spacing must be sufficient planted a minimum of 10 feet on- to ensure the plant material achieves 80% Plant Materials center. cover in the proposed planting areas within Plant ground cover plugs at 12 to 18 a 3-year period. If seed mixes are used, they should be from inches on -center; Plant container- a qualified supplier, should be appropriate grown plants at 18 to 24 inches on- for stormwater basin applications, and center, depending on the initial plant should consist of native species (unless the size and how large it will grow. seeding is to establish maintained turf). Available Soil Phosphorus (P). Plant -available soil P should be within the range of Low' (L') to Medium (M) as defined in Table 2.2 of DCR (2005) Virginia Nutrient Management Standards and Criteria. For the Mehlich I extraction procedure this equates to a range of 5 to 15 mglkg P or 18 to 40 mglkg P for the Mehlich III procedure. The filter media should contain sufficient plant available P to support initial plant establishment and plant growth, but not serve as a significant source of P for long term leaching. The media must also be relatively loose and non -compacted to allow for adequate inter -connected porosity to meet the required permeability (Ksat) specification. Saxton et al. (1986) estimated generalized bulk densities and soil -water characteristics from soil texture assumptions. The expected bulk density of the loamy sand soil composition described above should be in the range of 1.6 to 1.7 g/cm3. Maintenance Tasks Frequency • Mowing of grass filter strips and bioretention turf cover At least 4 times a year • Sot weeding. erosion repair. trash removal, and mulch raking Twice during growing season • Add reinforcement planting to maintain desired the vegetation density As needed • Remove invasive plants using recommended control methods • Stabilize the contributing drainage area to prevent erosion Spring inspection and cleanup • Supplement mulch to maintain a 3 inch layer Annually • Prune trees and shrubs • Remove sediment in re -treatment cells and inflow points Once every 2 to 3 years • Replace the mulch layer Every 3 years the soil mix with each runoff event and eventually fill or otherwise clog the void space randomly throughout the mix and create preferential flow paths. In the short term this can lead to short circuiting and reduced volume reduction and pollutant removal, and in the long term may clog the soil layer. This tendency is offset by addition and maintenance of appropriate amounts of soil organic matter which binds soil fines into larger non -mobile aggregates. • General Filter Media Physical Composition. The mineral soil texture of the bioretention soil mix should be loamy coarse sand with no more than 10% clay, no more than 20% silt + clay and at least 75% of the sand fraction should be coarse or very coarse sand. • To allow for appropriate Cation Exchange Capacity (CEC) and nutrient removal, the mix should contain at least 10% soil fines (sill + clay) while meeting the overall texture specification above. The particle size analysis must be conducted on the mineral fraction only or following appropriate treatments to remove organic matter before particle size analysis. • The Filter Media should contain 3% to 5% organic matter by conventional Walkley-Black soil organic matter determination method or similar analysis. Soil organic matter is expressed on a dry weight basis and does not include coarse particulate (visible) components. Version 2.0, January 1, 2013 VA DCR STORMWATER DESIGN SPECIFICATION NO. 9 Page 25 of 62 BIORETENTION • The overall particle size distribution of the mix will vary since the sand fraction may contain some finer sizes as will native topsoils if utilized. As stated previously, the goal of the mixture is to achieve the desired constant head permeability. Therefore, the filter media composition noted above serves as the target recipe for the three ingredients, while the ultimate performance goal is to achieve a verified soil permeability or hydraulic conductivity (Ksat) of 1 to 2 inches per hour (or 30 to 60 cm/day). • The following is the recommended composition of the three media ingredients: o Sand shall consist of silica based coarse aggregate, angular or round in shape and meet the mixture grain size distribution below. No substitutions of alternate materials such as diabase, calcium carbonate, rock dust or dolomitic sands are accepted. In particular, mica can make up no more than 5% of the total sand fraction. The sand fraction may also contain a limited amount of particles > 2.0 min and < 9.5 min per the table below, but the overall sand fraction must meet the specification of >75% being coarse or very coarse sand. Sieve Size % Passing 3/8 in 9.50 min 100 No. 4 4.75 min 95 to 100 No. 8 2.36 min 80 to 100 No. 16 1.18 min 45 to 85 No. 30 0.6 min 15 to 60 No. 50 0.3 min 3 to 15 No. 100 0.15 min 0 to 4 Effective Particle size (1310)> 0.3mm Uniformity Coefficient 60/D 10 < 4.0 o Topsoil is generally defined as the combination of the other ingredients referenced in the bioretention soil media: sand, fines (silt and clay), and any associated soil organic matter. Since the objective of the specification is to carefully establish the proper blend of these ingredients, the designer (or contractor or materials supplier) must carefully select the topsoil source material in order to not exceed the amount of any one ingredient. Generally, the use of a topsoil defined as a loamy sand, sandy loam, or loam (per the USDA Textural Triangle) will be an acceptable ingredient and in combination with the other ingredients meet the overall performance goal of the soil media. o Organic matter materials used in the soil media mix should consist of well - decomposed natural C-containing organic materials such as peat moss, humus, compost (consistent with the material specifications found in Design Specification #4 Compost Soil Amendments), pine bark fines or other organic soil conditioning material. However, per above, the combined soil mix should contain 3% to 5% soil organic matter on dry weight basis (grams organic matter per 100 grams dry soil) by the Walkley-Black method or other similar analytical technique. Pre -Construction Meeting ❑ Pre -construction meeting with the contractor designated to install the bioretention practice has been conducted. ❑ Identify the tentative schedule for construction and verify the requirements and schedule for interim inspections and sign -off. ❑ Subsurface investigation and soils report supports the placement of an bioretention practice in the proposed location. ❑ Impervious cover has been constructed/installed and area is free of construction equipment, vehicles, material storage, etc. ❑ All pervious areas of the contributing drainage areas have been adequately stabilized with a thick layer of vegetation and erosion control measures have been removed. ❑ Area of bioretention practice has not been impacted during construction. ❑ Stormwater has been diverted around the area of the bioretention practice and perimeter erosion control measures to protect the facility during construction have been installed. . Excavation ❑ Compare the bioretention surface and invert design elevations with the actual constructed elevations of the inflow and outlet inverts and adjust design elevations as needed. ❑ Area of bioretention excavation is marked and the size and location conforms to plan. ❑ If the excavation area has been used as a sediment trap: verify that the bottom elevation of the proposed stone reservoir is lower than the bottom elevation of the existing trap. ❑ For Level 2 bioretention, ensure the bottom of the excavation is scarified prior to placement of stone. ❑ Subgrade surface is free of rocks and roots, and large voids. Any voids should be refilled with the base aggregate to create a level surface for the placement of aggregates and underdrain (if required). ❑ No groundwater seepage or standing water is present. Any standing water is dewatered to an acceptable dewatering device. ❑ Excavation of the bioretention practice has achieved proper grades and the required geometry and elevations without compacting the bottom of the excavation. ❑ Certification of Excavation Inspection: Inspector certifies the successful completion of the excavation steps listed above. Filter Layer, Underdrain, and Stone Reservoir Placement ❑ All aggregates, including, as required, the filter layer (choker stone & sand), the stone reservoir layer or infiltration sump conform to specifications as certified by quarry. ❑ Underdrain size and perforations meet the specifications. ❑ For Level 2 installations: placement of filter layer and initial lift of stone reservoir layer aggregates with underdrain or infiltration sump, spread (not dumped) to avoid aggregate segregation; or ❑ Impermeable liner, when required, meets project specifications and is placed in accordance with manufacturers specifications. ❑ Sides of excavation covered with geotextile, when required, prior to placing stone reservoir aggregate; no tears or holes, or excessive wrinkles are present. ❑ Placement of underdrain, observation wells, and underdrain fittings (45 degree wyes, cap at the upstream end, etc.) are in accordance with the approved plans. ❑ Elevations of underdrain and outlet structure are in accordance with approved plans, or as adjusted to meet field conditions. ❑ Placement of remaining lift of stone reservoir layer as needed to achieve the required reservoir depth. ❑ Certification of Filter Layer and Underdrain Placement Inspection: Inspector certifies the successful completion of the filter layer and underdrain placement steps listed above. Bioretention Soil Media Placement ❑ Soil media is certified by supplier or contractor as meeting the project specifications. ❑ Soil media is placed in 12-inch lifts to the design top elevation of the bioretention area. Elevation has been verified after settlement (2 to 4 days after initial placement). ❑ Side slopes of pending area are feathered back at the required slope (no steeper than 3H:1V). ❑ Certification of Soil Media Placement Inspection: Inspector certifies the successful completion of the soil media steps listed above. Pretreatment and Plant Installation ❑ Placement of energy dissipators and pretreatment practices (forebays, gravel diaphragms, etc.) are installed in accordance with the approved plans. ❑ Riser, overflow weir, or other outflow structure is set to the proper elevation and functional; or. ❑ External bypass structure is built in accordance with the approved plans. ❑ Appropriate number and spacing of plants are installed in accordance with the approved plans. ❑ All erosion and sediment control practices have been removed. ❑ Follow-up inspection and as -built survey/certification has been scheduled ❑ GPS coordinates have been documented for all bioretention practice installations on the parcel. U CRAIG W. J. KOTARSKI Lic. No. 0402048507 n E 0 0 N U N C > E w ° E -Z Q .. 3 U. 0U.0 o < J U 00 W J -N d N N N 3: 0 v X 9�< 0 Q 7 /) = N = U > < Lq vi O N � M a� OJ J �H Ui O x c� 0 x F 0 w w x Z O > Z) 0 r t7 Z O a K U w Z O v7 > W w 0 DATE 0210712022 DRAWN BY VAN NIEK DESIGNED BY J. DENKO CHECKED BY C. KOTARSKZ SCALE N/A W Z O Q zw� ~ U J O w Q m Q U O u- }O ~ Q 0 U C G 0 U) L JOB NO. 46883 SHEET NO. C7.7 BMP: WET POND - LEVEL 1 BMP: Bio 1A - LEVEL 1 BMP: Bio 113 - LEVEL 2 BMP: Bio 1C - LEVEL 1 Runoff Coefficients (Rv) A Soils B Soils C Soils D Soils Forest/Open Space 0.02 0.03 0.04 0.05 Managed Turf 0.15 0.20 0.22 0.25 Impervious Cover 0.95 0.95 0.95 0.95 Proposed Condition forTR-55 HSG RCN Area(ac) -A RCNxArea 1 (Impervious) 98 6.48 59% 635 A(Managed Turf) 61 1.89 17% 115 B (Managed Turf) 55 2.66 24% 146 TOTALS 11.03 68 RCN = 68 Site RV (Rv Coefficients x Land Cover %) Managed Turf ASoils, Rv = 0.03 Managed Turf B Soils, Rv = 0.05 Impervious, Rv = 0.56 Rv = 0.63 Treatment Volume, Tv (Spec. No. 14, Table 14.3) Tv = [((1.0 in) x (Rv) x (A))-* 12] - vol ume reduced by upstream BMP Drainage Area, A= 480,306 sf Upstream Volume Treated= 8,924 cu ft *per RRM 3.0 Col umnE Treatment Volume, Tv = 16,367 Cu ft Required Treatment Volume - Stage Storage for Tv El Area (sf) Incr. Volume cu ft Total Volume cu ft 413 2,973 0 0 414 4,629 3,771 3,771 415 6,479 5,528 9,299 416 8,520 7,476 16,775 417 10,753 9,615 26,390 Treatment Volume, Tv = 26,390 cu ft Provided Forebay Volume Forebay Vol ume = (0.10 - 0.25 inches per I mpv. Acre) Impervious Area to Wet Pond = 6.48 ac [0.10) [0.25] Impervious Runoff / Impervious Acre = 2,350 11 5,876 cu ft Required Range Forebay Volume / Treatment Volume 11 19% < 15% Stage Storage for Forebay #1 El Area (sf) Incr. Volume (cu ft) Total Volume (cu ft) 413 965 0 0 414 1,396 1,174 1,174 415 1,881 1,632 2,806 416 2,421 2,145 4,952 Total Pond Volume Pond Bottom Elev. = 413.0' El Depth (To Pond Bottom Area sf ( ) Incr. Volume cu ft Total Volume cu ft) 413 0.0 2,973 0 D 414 1.0 4,629 3, 771 3,771 415 2.0 6,479 5,528 9,299 416 3.0 8,520 7,476 16,775 417 4.0 10,753 9,615 26,390 418 5.0 13,205 11,958 38,348 419 6.0 15,882 14,523 52,871 420 7.0 18,782 17,312 70,183 421 8.0 21,904 20,323 90,506 422 9.0 25,204 23,535 114,040 423 10.0 28,589 26,879 140,919 424 11.0 32,074 30,315 171,234 425 12.0 35,660 33,851 205,085 426 13.0 39,346 37,488 242,573 Total Pond Volume = 242,573 cu ft Provided Length to Width Option = 2LAW L= Length from inlet to outlet (ft) W =Average Width (ft) L/W >2 [Required] DID >ET+INF+RES-MB L = 284 ft W = 64 ft L/w ? 4.4 ft OK!, Basin L to W Ratio is 2.0 or greater DP: Average des igndepth ofthe permanentpool (inches) ET: Summer eva po-tra ns pi ra tf on rate(i nch es)(a ss u me 8 i nch es) INF: Monthly infiltration loss (assume 7.2 Qo 0.01 inch/hour) RES: Reservoir of water far a factor of safety (assume 24 inches) MB: Measured baseflow rate to the pond,if any (convert to inches) DP > (8)+( 48 > 39.2 Runoff Coefficients (Rv) A Soils B Soils C Soils D Soils Forest/Open Space 0.02 0.03 0.04 0.05 Managed Turf 0.15 0.20 0.22 0.25 Impervious Cover 0.95 0.95 0.95 0.95 Proposed Condition forTR-55 HSG RCN Area(ac) % RCNxArea I (Impervious) 98 0.81 70% 79 A (Managed Turf) 61 0.00 0% 0 B (Managed Turf) 55 0.35 30% 19 TOTALS 1.16 68 RCN = 68 Site Rv (Rv Coefficients x Land Cover %) Managed TurfASoils,Rv= 0.00 Managed Turf B Soils, Rv = 0.06 Impervious, Rv = 0.66 Rv= 0.72 Treatment Volume, Tv (Spec. No. 9, Table 9.4) Tv = [1(1.00 in) x (Rv) x (A))+121 -volume reduced by upstream BMP Drainage Area, A= 50,454 sf Upstream Volume Treated = 0 cu ft *per RRM 3.0 Column E Treatment Volume, Tv = 3,035 tuft Required Treatment Volume - Storage Depth Storage Depth (ft) Void Ratios Pending Depth= 0.75 1.00 Depth of Media Filter= 3.00 0.25 Stone Sump Depth= 1.25 0.40 Treatment Volume, Tv = 2.00 ft Provided Treatment Volume - Surface Area Minimum Required Surface Area= 1,517.46 sf Surface Area Provided= 1,796 sf Forebay Volume Required Forebay Volume= 455 cf Provided Forebay Volume= 511 cf BMP: Bio 1D - LEVEL 1 Runoff Coefficients (Rv) A Soils B Soils C Soils D Soils Forest/Open Space 0.02 0.03 0.04 0.05 Managed Turf 0.15 0.20 0.22 0.25 Impervious Cover 0.95 0.95 0.95 0.95 Proposed Condition forTR-55 HSG RCN Area(ac) % RCNxArea 1 (Impervious) 98 0,34 45% 32,84214876 B (Managed Turf) 61 0.41 55% 24.87612489 B (Forest) 55 0.o0 0% 0 TOTALS 0.74 78 RCN = 78 Site Rv (Rv Coefficients x Land Cover %) Managed Turf B Soils, Rv= 0.11 Forest B Sol Is, Rv = 0.00 Impervious, Rv= 0.43 Rv= O.S4 Treatment Volume, Tv (Spec. No. 9, Table 9.4) Tv = [((I.AO i n) x (Rv) x (A)) =12] - volume reduced by upstream BMP Dra I nage Area, A = 32,362 sf Upstream Vol ume Treated = 0 tuft per RRM 3.0 Column E Storage Depth= 1,452 cu ft Required Treatment Volume - Storage Depth Storage Depth (ft) Void Ratios Ponding Depth= 0.50 1.00 Depth of Media Filter= 3.00 0.25 Stone Sump Depth= 1.25 0.40 Treatment Volume, Tv = 1.7S ft Provided Treatment Volume - Surface Area Minimum Required Surface Area= 829.57 sf Provided Forebay Volume= 1,341.00 sf Runoff Coefficients (Rv) A Soils a Soils C Soils D Soils Forest/Open Space 0.02 0.03 0.04 0.05 Managed Turf 0.15 0.20 0.22 0.25 Impervious Cover 0.95 0.95 0.95 0.95 Proposed Condition for TR-55 HSG RCN Area(ac) % RCNxArea 1 (Impervious) 98 0.25 72% 24.54049587 B (Managed Turf) 61 0.10 28% 5.819926538 B (Forest) 55 0.00 0% 0 TOTALS 0.35 88 RCN = 88 Site Rv (Rv Coefficients x Land Cover %) Managed Turf B Soils, Rv= 0.06 Forest B Soils, Rv = 0.00 Impervious, Rv = 0.69 Rv = 0.74 Treatment Volume, Tv (Spec. No. 9, Table 9.4) Tv = [1(1.25 in) x (Rv) x (A))+ 121 - volume reduced by upstream BMP Drainage Area, A= 15,064 sf Upstream Volume Treated = 0 cu ft *per RRM 3.0 Column E Treatment Volume, Tv= 1,166 cult Required Treatment Volume - Storage Depth Storage Depth (ft) Void Ratios Ponding Depth= 0.50 1.00 Depth of Media Filter= 3.00 0.25 Stone Sump Depth= 1.25 0.40 Storage Depth= 1.75 ft Provided Treatment Volume - Surface Area Minimum Required Surface Area= 666.30 sf Surface Area Provided= 684.00 sf Forebay Volume Required Forebay Volume= 175 cf Forebay Volume Provided= 175 cf Runoff Coefficients (Rv) A Soils B Soils C Soils D Soils Forest/Open Space 0.02 0,03 0.04 0.05 Managed Turf 0.15 0.20 0.22 0.25 Impervious Cover 0.95 0.95 0.95 OAS Proposed Condition for TR-55 HSG RCN Area(ac) % RCNxArea 1 (Impervious) 98 0.82 58% 80.84775023 B (Managed Turf) 61 0.59 42% 36.06365932 B (Forest) 55 0,00 0% 0 TOTALS 1A2 83 RCN = 83 Site Rv (Rv Coefficients x Land Cover %) Managed Turf B Soils, Rv= 0.08 Forest B Soils, Rv = 0.00 Impervious, Rv = 0.55 Rv = 0.64 Treatment Volume, Tv (Spec. No. 9, Table 9.4) Tv = [((1.00 in) x (Rv) x (A))+ 12) -volume reduced by upstream BMP DrainageArea,A= 61,689 sf Upstream Vol ume Treated = 0 cu ft *per RRM 3.0 Column E Treatment Volume, Tv= 3,274 aft Required Treatment Volume -Storage Depth Storage Depth (ft) Void Ratios Ponding Depth= 1.00 1.00 Depth of Media Filter= 3.00 0.25 Stone Sump Depth= 1.25 0.40 Treatment Volume, Tv = 2.25 ft Provided Treatment Volume - Surface Area Minimum Required Surface Area= 1,455.18 sf Surface Area Provided= 1,502,00 sf Forebay Volume Required Forebay Volume= 491 cf Surface Area Provided= 520 cf BMP: Bio 2A - LEVEL 1 Runoff Coefficients (Rv) A Soils B Soils C Soils D Soils Forest/Open Space 0.02 0.03 0.04 0.05 Managed Turf OAS 0.20 0.22 0.25 Impervious Cover 0.95 0.95 0.95 0.95 Proposed Condition forTR-55 HSG RCN Area(ac) % RCNxArea 1 (Impervious) 98 1.51 65% 148.0360193 B (Managed Turf) 61 0.82 35% 50.02042011 B (Forest) 55 0.00 0% 0 TOTALS 233 85 RCN = 85 Site Rv (Rv Coefficients x Land Cover %) Managed Turf B Soils, Rv= 0.07 Forest B Soils, Rv = 0.00 Impervious, Rv = 0.62 Rv = 0.69 Treatment Volume, Tv (Spec. No. 9, Table 9.4) Tv = [((1.00 in) x (Rv) x (A))+ 12) - vol ume reduced by upstream BMP Drai nage Area, A = 101,520 sf Upstream VolumeTreated = 0 cu ft *per RRM 3.0 Column E Treatment Volume, Tv = 5,805 cu ft Required Treatment Volume -Storage Depth Storage Depth (ft) Void Ratios Ponding Depth= 0.50 1.00 Depth of Media Filter= 3.00 0.25 Stone Sump Depth= 1.25 0.40 Treatment Volume, Tv = 1.75 ft Provided Treatment Volume - Surface Area Minimum Required Surface Area= 3,316.88 sf Surface Area Provided= 3,370.00 sf 'n.. U CRAIG W. J. KOTARSKI Lic. No. 0402048507 .�d, 02-0-1-22, m E 0 0 rn u N vi N C > E w °i E Z zR: u � o w O' O L rn Q J U o W J -N > d N N N v x - oa �v � _ N = U > ko ui c a, O N � M OJ CD w W � F- ui 0 O C7 O o_ x F O W w_ U Q z O 00 > 0 0 r z O d K U U0 w 0 z O v7 > W W H Q DATE 0210712022 DRAWN BY R. VAN NIEKER DESIGNED BY J. DENKO CHECKED BY C. KOTARSKZ SCALE N/A U) Z 0 Q J zwaf ~ z J O LU Q m a U 0 LL O O U �G�/ LL_ 0 U) c 5 a > ._ U c 12 h m m 0 EL a m fe L Required Forebay Volume= 218 cf Surface Area Provided= 391 cf Required Forebay Volume= 871 cf Volume Provided= 914 cf JOB NO. 46883 SHEET NO. C7.8 ROUTE PROJECT Rio Point DESIGNER: J. Danko DATE 12130/2021 ROUTE PROJECT Rio Point DESIGNER J. Danko DATE 12/30/2021 CHECKED: C. Kotarski UNITSNGLISH CHECKED: C. Kotarski UNITS iNGLISH � ALTH OFL Y G C 5t-' CRAIGW.7.K )TARSKI y Lic. No. 0402048507 �t 02-0-1-22� osSIONAL� G9®:4 M E 0 0 U N C N C ui > E w 4i E Qw++ 3 w 0 w o K O L M Q J U 00 Z w -N O .. d N N N d v W 4 M R tY 3 0 ) X J Q w w 0 4 O t)_ N Z = U > m O c ^ n U N w M a � W J H ui O C7 O F O w w w = Q Q z O in DATE 0210712022 0 O r DRAWN BY R. VAN NIEKER • DESIGNED BY • J. DENKO • CHECKED BY C. KOTARSKI • • SCALE N/A • VJ Z O Q J zw� U ~ < J O W Q -J U a L o 0 � Q 0 U C z 0 0 U) JOB NO. 46883 SHEET NO. C7.9 INLET Q 3 W N �Jwm� z v' o� I D f✓J c Sag Inlets Only cK � $ � �i a c � v 204 DI-3B 6.000 0.180 0.90 0.162 O.OW'RI(Hi'T 0.162 4 0.(x{R 0 0.648 0.0200 0.0208 5.138 0.(N70 0 0.0208 l 0.732 2.00 0.0833 0.0818 8.630 6.(1()0 0.695 0.882 0.572 0.076 1.282 206 DI-3C 6.000 0.2W 0.87 0.174 Back/Lt. D.000RKi-FF 0.174 4 0.696 0 0.0200 0.0208 5.277 0.000 0 0.0208 1 2.00 Back/Lt. 0 4 0 0 Ahead/Rt. 0.696 0.0200 6 0696 L196 0.166 0.333 0.498498 3.196 4.792 Weir Flow 208 DI-3C 6.000 0.250 0.88 0.22 Back/Lt. 0.000'RIC�7-t'F 0.22 4 0.88 0 0.0200 0.0208 5.762 0.000 0 0.0208 1 2.00 Back/iS. 0 4 0 0 Ahead/Rt. 0.880 0.02W 6 0.880 1.399 0.166 0.333 0.498498 3.399 5.603 Weir Flow 210 DI-1 2.000 0.110 0.80 0.088 Back/Li. 0.000'RIGHT 0.088 4 0.352 0 0.0200 0.0208 4.088 0.000 0 0.0208 1 2.00 Back/Lt. 0 4 0 0 Ahead/Rt. 0.352 0.02W 2.000 2 0.352 1.383 O.166 3.383 5.539 Weir Flow 212 DI-3C 6.000 0.290 0.80 0232 Back/Li. 0.000'RIGHT 0232 4 0.928 0 0.0200 0.0208 5.878 0.000 0 0.0208 1 2.00 Back/Lt. 0 4 0 0 Ahead/Rt. 0.928 0.0200 6 0.928 1.449 0.166 0.333 0.498498 3.449 5.806 Weir Flow 214 DI-3B 6.000 0.360 0.65 0.234 0.000'R1GHT 0.234 4 0.936 0 0.936 0.0200 0.0708 5.897 0.000 0 0.0208 1 0.669 2.00 0.0833 0.0766 10.479 6.000 0.573 0.783 0.733 0.203 1.472 216 DI-3B 4.000 0.080 0.82 0.0656 Back/Li. O.OW'RI(Y-IT 0.066 4 0.264 0 0.0200 0.0208 3.671 0.000 0 0.0208 1 2.00 Back/Lt. U 4 0 0 Ahead/Rt. 0.264 0.0200 4 02Ci4 0.732 0.166 0.333 0.498498 2.732 2.933 Weir Flow 218 DI-3C 6.000 0.380 0,80 0304 Back/Li. 0.000RiGHT 0.304 4 1.216 0 0.0200 0.0208 6.504 0.000 0 0.0208 1 2.00 Back/Lt. U 4 0 0 Ahead/Rt. 1.216 0.0200 6 1.216 1.735 0.166 0.333 0.498498 3.735 6.952 Weir Flow 220 DI-3C 2.000 0.250 0.84 0.21 Bacls/Lt. O.UOD'RIG[iT 0.21 4 0.84 0 0.001 0.0208 8.796 2.000 0.22738. 0.0833 4.00481 3.50 Back/U. 0 4 U 0 Ahead/Rt. 0.840 0.001 2 O.R40 1.943 0.166 0.333 0.498498 3.943 7.782 T> 8.0 ft 222 DI-3C 6.000 0.510 0.75 0.3825 Back/Lt. 0.000'RIGHT 0.383 4 1.532 0 0.0200 0.0208 7.092 0.000 0 0.0208 1 2.00 Back/Lt. 0 4 0 0 Ahead/Rt. 1532 0.0200 6 LS32 2.024 0.166 0.333 0.498498 4.024 8.111 T> 8.0 ft 224 DI-3C 6.1100 0.330 0.75 0.2475 Back/Lt. 0.000'RI(�-I'C 0248 4 0.992 0 0.0200 0.0208 6 026 0.000 0 0.0208 L 2.00 BacklLt. 0 4 0 0 Ahead/Rt. 0.992 0.0200 6 0.992 1.515 0.166 0.333 0.498498 3.515 6.070 Weir Floe 232 DI-3B 6.000 0.240 0.74 0.1776 0.000'RIGHT 0.178 4 0.712 0 0.712 0.0200 0.0200 5.455 0.000 0 0.0200 I 0.705 2.00 0.0833 0.0787 9.189 6.000 0.653 0.951 0.606 0.106 1.309 236 DI-1 1.000 0.300 0.43 0.129 Back/Lt. O.000RIGHT 0.129 4 0.516 0 0.0200 0.0208 4.718 0.000 0 0.0208 I 2.W Back/Lt. 0 4 0 0 Ahead/Rt. 0.516 0.0200 1.000 t 0.516 2.747 0.166 4.747 11.007 T> 8.0 ft 238 DI-1 L000 0.270 0.50 0.135 Back/Lt. O.OlI0R1GH'F 0.135 4 0.54 0 0.0200 0.0209 4799 0.000 0 0.0208 I 2.W Back/Lt. 0 4 0 0 Ahead/Rt. Q540 0.0200 LOW 1 0.540 2.832 0.166 4.832 11.345 T> 8.0 ft 240 Dl-3B 6.000 0.460 0.70 0.322 Back/Lt. O.000Ri($t'i' 0.322 4 128R 0 0.0200 0.0208 6645 0.000 0 0.0209 I 2.00 Back/Lt. 0 4 0 0 Ahead/Rt. 1.288 0.0200 6 1.288 1.803 0.166 0.333 0.498498 3.803 7224 Weir Flow 242 D1-3B 6AU0 0420 0.80 0.336 Back/Lt. O.DOORi($i'i' 0.336 4 1.344 0 00200 0020R 6752 0.000 0 0.0208 1 2.00 BacWLt. 0 4 0 0 Ahead/Rt. 1.344 0.0200 6 1.344 1.855 0.166 0.333 0.498498 3.853 7432 Weir Flow 244 DI-3B 6.000 0.420 0.73 0.3066 Back/Lt. O.000RIl34'F O:i07 INLET < Q^ J "' J J - � x i C � 3 W J x � �� w ,.`�'j� �� i (] _ % .F-. W '-. E4 ,� �.'� % � _� N i F' ,j o () •- � � cs uu]] U 5� a 'iV z U Sag Inlets Only .Y W F � m 9 ^ �u � 3 o a z_ .O. 0 Q 246 DI-3B 6.000 0.440 0.80 0.352 Back/Lt, O.000RICiliT 0.352 4 1.40R 0 0.0200 0.0208 6.871 O.000 0 0.0208 1 2.00 Back/Lt. 0 4 0 0 Ahead/RT. L408 0.0200 C, 1.40R 1.914 0.16fi 0.333 0.49R49R 3A14 7.6fi7 Weir Floc 248 DI-3B 6.000 0.220 0.80 0.176 Back/Lt. 0.000'RICdiT 0.176 4 0-704 0 00200 00208 5300 0.000 0 0.0208 1 2D0 Back/Lt. 0 4 0 0 Ahead/Rt. 0.704 0.0200 6 0.7U4 1.205 0.166 0.333 0.498498 3.205 4.829 Weir Flow 250 D1-1 L250 0.190 0.35 Q0665 Back/Lt. 0.000'RIC$iT 0.067 4 0.268 0 0.0200 0.0208 3.G91 0.000 0 0.0208 1 2.00 BacWLt. 0 4 0 0 Ahead/Rt. D26R 0.02U0 1.250 1.25 0268 1.528 0.166 3.528 6.123 Weir Flow 402 DI-3B 6.000 0.340 O.RO 0.272 D.000RIGHT 0.212 4 l ORR 0 1.088 0.02W 0.0208 6.238 O.OW 0 0.020R 1 0.644 2.00 O.OR33 0.0744 1] 353 G000 0.528 0.742 0.807 0.281 1.557 406 DI-3B 6.000 0.130 0.68 0.0884 Back/Lt. 0.000'RIGHT O.OR8 4 0.352 0 0.0200 0.020R 4.088 0.000 0 0.0208 1 2.00 BacldLt. 0 4 0 0 Ahead/Rt. 0.352 0.0200 6 0.352 0.759 0.166 0.333 0.498498 2.759 3.041 Weir Flow 502 DI-3B 6.000 0.180 0.86 0.1548 U.000RI(;FIT O.ISS 4 0.62 0 0.620 0.0200 0.0208 S.OS4 0.000 0 0.0208 1 0.739 2.00 O.OR33 0.0824 8.433 6.000 0.711 0.893 0554 0.0G6 1.261 SU4 DI-3B 6.000 0.17U 0.80 U.136 BacldLt. O.000RIQTT 0.13G 4 0.544 0 0.0200 0.0208 4.812 0.000 0 0.0208 I 2.00 Back/Lt. 0 4 0 0 Ahead/Rt. 0.544 0.0200 6 0.544 1.U15 0.16(i 0.333 0.498498 3.015 4.066 Weir Flow 602 D1-38 6.OW 0.390 0.50 O.195 O.000RIGHT 0.195 4 0.7R 0 0.7R0 0.02W 0.0208 5.507 0000 0 0.0208 1 0.700 2.00 QOR33 0.0742 9.515 6.000 0.631 0.833 0.650 0. I30 1.375 804 D1-1 L000 0.190 0.30 OA57 Back/Lt. O.000RIGHT 0.057 4 0.228 0 0.0200 0.0208 3.474 0.000 0 0.0208 1 2.00 BacULt. 0 4 0 0 Ahead/Ri. 0.228 0.0200 LWO 1 0.228 1.594 0.166 3.594 6.385 Weir Flow 806 DI-1 1.000 0.430 0.30 0.129 Bach/Lt. O.000RI(3iT 0.129 4 O.SIfi 0 0.0200 0.020R 4.718 0.000 0 0.020R 1 2.W BacldLt. 0 4 0 0 Ahead/Rt. 0.516 U.0200 1.000 I 0.516 2747 0.166 4.747 11.007 T > 8.0 ft 810 DI-1 1.000 0.280 030 DOR4 Bac1JLt. O.OW'RIGHT O.OR4 4 0.336 0 0.0200 0.0208 4.017 0.000 0 0.020R I 2.00 Back/Lt. 0 4 0 0 Ahead/Rt. 0.336 0.0200 1.000 1 0.336 2061 0.166 4.OG4 8.269 T > 8.0 ft L F- S:\103k16883-Wetsel_Property\DWGtSheet\CD\46883-103-C8.0-PROF_STORM.dwg I Plotted on 2/7/2022 11:18 AM I by Jessica Danko + 442.0 co + A O -4 W 208: DI-3B 6 ft Throat STA 15+40.14 0 TOP 459.11 (n o INV IN 451.28 (209) o INV OUT 451.18 (207) 100: EW-2 - 48" Pipe - 2:1 Fill Slope G 3: STA 10+21.25 TOP 414.86 N Q INV IN 409.53 (101) o0 O o D D r Cn m M. 210: DI-3B 6 ft Throat O 0 STA 16+56.96 N TOP 459.98 INV IN 452.44 (211) INV OUT 452.44 (209) 102: Cylinder STA 11+41.87 0 o NOV OUT 4110.74 (101) o O v 212: DI-3B 4 ft Throat STA 17+88.64 00 ++ TOP 461.42 0o INV IN 453.86 (213) "� o INV OUT 453.76 (211) + A N °) O O < 0 0 0 206: 24 x 24 inch Rectangular Structure O + N 0 STA 10+00.00 CD CID TOP 458.47 n INV IN 450.71 (207) (o INV IN 453.00 (221) INV OUT 442.34 (205) � N 222: DI-3B 6 it Throat Clio N STA 10+53.25 N TOP 459.04 O INV OUT 454.00 (221) 00 Z N N <z A 0 A O _ O < v + cn < CT 0 .1 Z /n O V/ (J o � N rn cri > r (no N "W ON= m 00 T�T O O O A N� r D N O O N O mm 41�Ec�n N `h O O 216: DI-3B 6 ft Throat STA 20+48.21 TOP 460.96 0 INV IN 456.70 (217) n INV OUT 456.60 (215) M 0 0 N N + O O 218: DI-36 6 ft Throat STA 22+39.99 TOP 464.97 INV IN 460.70 (219) INV OUT 460.80 (217) N w it 0 0 m O A 11 O < N O A Cn o 0 200: ES-1 for 36 inch Pipe o rn D W 0 11� STA 10+00.00 o a A TOP 416.85 O A + INV IN 413.60 (201) j -4 O1 S 0 °0(Oo(oo° 202: MH-2 STA 10+59.01 TOP 429.07 INV IN 418.42 (223) A INV IN 419.30 (203) (Ni+i o + INV OUT 418.42 (201) 0 0 Cn N O N O+ 0 o m00 i N D 00 r r m ri ii' ui O �� O w 0 O • • Z O I- -n�-n -m m I"ODOz(n „MmMM 171 m D Cl) Zzz = o/- /- \ \ (7 r -i -U o Z Z D X www�a CO Z (n rn ou 0 N C C �N��AAA N N N W N CnrCCn w.o.omVN i D'' m" � D Cf) m m Cn �� m n Z n ,l o «<0yrn OP A A A rTI cn cn co o x A W O-4 N N A N O o j v A O A N (n O o n o O�� CD CD A n c' r- C M w m Cn 00 n c D r l o m THIS DRAWING PREPARED AT THE CO •• CHARLOTTESVILLE OFFICE Orb TIMMONS ROUP• • YOUR VISION ACHIEVED THROUGH OURS. y� n � 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 y�9 �i; TEL 434.295.5624 FAX 434.295.8317 www.timmons.com O No q rt A DATE REVISION DESCRIPTION r O o ? �(n o o RI O POINT I-t � m o ' o 7 r z o COUNTY OF ALBEMARLE, VA m n o 2 m z zz N 1 w STORM PROFILES ° ° m ` s ti A O \ O t�Jr O CJr ^ A � (OJr \ o2(N7+0 � v \ am0 448.0 \ \ ��� I-; 455.2 N O O N -coO \ omo \ \ 480.9 v7 CO 484.3 � m 0 l m0 486.4 / / 483.9 481.3 / 459.1 � N I cv^?w am� / � 4573 / O co m / l7 N n cn l � D z 4554 m � A � 456.3 � � 459.5 � � N '-� 462.0 \ amp r 452.8 \ 484.0 485.4 Ce 456.7 O 0 488.2 A I A cAi, (An m OAI o (n o (n o v, O N N Cn O Cn O Cn �o \ � oho' m O D \ °m0 m l7 Cn O Cn O Cn W A A U CA11 � v, o cn o cn o 441.2 \ v7� � °mcZi a o"'� ;a ;0 DO 444.9�m O m v W A A CA7r (A1r m v, o cn o (n o A A (A71 CA71 O (n O Ut O (7r O (n O (n 440.4 � l S ��� � �� \ 443.0 (Qi / / / 441.3 I m GZi LJ 440.1 / / I 437.5 430.9 / w�v' ao i m0'� \ 433.E \ DO l7 � \ m� \ o 437.1 1 4372 I / 434.5 C e \ \ 442.0 ?y�3�� \ e o � \ r \ J \ o o o o 448.0 o cn cNrr (wrr cAir c�ir These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. F- S:\103k16883-Wetsel_Property\DWGtSheet\CD\46883-103-C8.0-PROF_STORM.dwg I Plotted on 2/7/2022 11:18 AM I by Jessica Danko N 451.5 +° o Cn O coil 228: DI-3B 6 ft Throat STA 12+28.07 N TOP 460.92 INV IN 450.00 (229) INV OUT 449.90 (227) o z z z O CD" <p O <G<�yo �X CpAALn rn + W �N 256:DI-3A Aomoo is n n STA 10+42.08 m c^' °' O o y. 024" Basin -Circular Grate 1 NVI N 450.87 (257) N r N O 7 O STA 13+06.13 m m cn cn n TOP 460.50 n N INV OUT 450.77 (255) v v v INV IN 450.87 (231) Cn v, INV OUT 450.78 (229) 258: 12" Basin -Circular Grate m' o STA 10+99.00 fD O TOP 456.00 232: DI-36 6 ft Throat 1l INV OUT 451.44 (257) STA 13+81.67 rn TOP 460.32 m o INV IN 452.96 (233) �+, O INV OUT 452.86 (231) O 0 A O V O 226: DI-3B 6 ft Throat 00 (n o STA 10+00.00 TOP 461.28 INV IN 447.50 (227) INV IN 456.08 (241) N INV OUT 447.07 (225) cn Q 234: DI-3B 6 ft Throat m O 242: 15" Basin - Circular Grate O STA 10+73.51 N STA 15+7g.17 I N (n TOP 462.73 TOP 462.36 n n N INV IN 457.77 (243) + INV IN 455.03 (235) + (�0 O > > o INV OUT 457.67 (241) o INV OUT 454.93 (233) m m � o _ N MOO II �CS cn o N (nCn CID D D 236: DI-3B 6 ft Throat m m STA 16+54.11 m m N TOP 463.41 O INV IN 455.86 (237) ° Q INV OUT 455.76 (235) - 244: 15" Basin -Circular Grate r STA 11+84.79 + m + TOP 464.06 o o INV OUT 460.00 (243) O r _ A mLa N O + O a o + + 0 o con 238: DI-3B 6 ft Throat STA 18+25.32 TOP 465.53 INV IN 460.61 (239) 0 224: Cylinder INV OUT460.51 (237) o STA 10+00.00 TOP 448.20 INV IN 439.64 (225) INV IN 432.17 (249) INV OUT 431.42 (223) + 0 0CD O V1 .� 250: 24" Basin -Circular Grate STA 11+28.82 TOP 456.00 ++ 240: DI-3B 6 ft Throat m O N INV IN 449.60 (251) o STA 20+04.14 � N N 22 INV IN 450.35 (255) TOP 468.84 rn cn INV OUT 449.50 (249) INV OUT 464.17 (239) n n t D� r m !? cn + O 252: 24" Basin - Circular Grate N STA 12+13.30 Ul TOP 462.52 INV IN 451.06 (253) INV OUT 450.96 (251) 0 0 w 0 0 254: 24" Basin - Circular Grate STA 13+28.58 TOP 461.00 INV OUT 453.37 (253) A A (n + O O O A OCn n J O 202: MH-2 (n o STA 10+00.00 TOP 429.07 INV IN 418.42 (223) INV IN 419.30 (203) • • O C:) INV OUT 418.42 (201) - f l N >77 2TACylinder Iv O D O r- .Cn . _ STA 10+58.37 -n .0 M .a m TOP 448.20 m m m � O INV IN 439.64 (225) m � D A N (n INV IN 432.17 (249) .Z�l r = 0 CO INV OUT 431.42 (223) C CQ Cn D D> o C� D � -U mm 07 -- Z N C C Ch M o Q 226: DI-3B 6 ft Throat m Cn STA 11+35.69 Cn r C Cn TOP 461.28 � i m L �j INV IN 447.50 (227) D O INV IN 456.08 (241) D (n INV OUT 447.07 (225) m m Cn r �� m m+ =m c� 0o D C7 z T, m 228: DI-3B 6 ft Throat - o STA 12+28.07 0 ,X o TOP 460.92 O N Cn INV IN 450.00 (229) r + o INV OUT 449.90 (227) W c> D r mo THIS DRAWING PREPARED AT THE CO •• CHARLOTTESVILLE OFFICE pub TIMMONS ROUP• • YOUR VISION ACHIEVED THROUGH OURS. y� n � 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 y�9 �i; TEL 434.295.5624 FAX 434.295.8317 www.timmons.com O No q rt A DATE REVISION DESCRIPTION r O o ? �= oo RIO POINT �N m �m o 'o� r ° n vO N ' z C o COUNTY OF ALBEMARLE, VA vi m n 70 o 2 m z N 1 FN� w STORM PROFILES ° ° m ` ti A o o/ o o cAn cc"i, cot, 450.2 SOON O o m0 \ 453.3 N J I 453.E � '� N O m m o �' a CIO t7 \ 457.E n O � \ Z O 483.7OW488.8 ��489.1 JG) / 489.8 �Sm 487.3 0 � O / om n � rn / D m / vpi A / 464.9 Z \L-04 / can__ N 4825 Z c° cO'OOT / om 481.2 481.3 I w �rnz \ � D J I 483.0 L7� 'o a'mT I 463.2 465.3 o cAi, o cot, o cot, o o cAn o c�ir o 454.5 � (n (� (T N 1 � ? � � I N � � O � � Z s m °' 455.9 O�jN op sm O� ODD DO �� mz mupi A A UAi � UAi � OAi l7 o cn o cn o A CAir cA7r OA1 � Ul O U1 O cT 452.7 r in N 'p 1 455.4 a° 1 \1 456.7 1 mo 4575 hW m Vz ao G7 mZ O A VAi CA7r � � Vl O U1 O U1 W W A A CA7r cA7r OA1 O cT O c71 O c71 O r � � \1 O m o �8y?O 0 I I ' 07 f7r \ s m �' \ n � � D � n O cpnm? � I �D ��<^_' oa°'-c�'' � 1 IAA°-' \ A W A W A T A A A A A Cn A Cn o (T O CT O CT O A_ A N i N W Cl)W A A CA1i (AT � O V1 O V1 O V1 O cT O U1 O 443.9 449.8 6g ?3 \ 36„ , pF o �22. AE � co 451.E tiogp,� \ 4526 WN � N � I Z�� I O� 451.5 � / C A A A Cl) A A A A A 450.2 o cn o cN+, twit o vAi coir o These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express wdtten consent of TIMMONS GROUP. F- S:\103k16883-Wetsel_Property\DWGtSheet\CD\46883-103-C8.0-PROF_STORM.dwg I Plotted on 2/7/2022 11:18 AM I by Jessica Danko co co + + o rn O rn O O I0 700: ES-1 for 18 inch Pipe o 204: MH-2 X o+ STA 10+00.00 0+ STA 10+00.00 x O TOP 441.17 o TOP 443.39 r<n v INV IN 439.50 (701) INV IN 438.14 (245) N O INV IN 436.29 (205) Cn U) O 702: 24" Basin -Circular Grate INV OUT 435.79 203) C) 0 STA 10+35.36 D i I TOP 446.00 m m (n INV OUT 441.50 (701) I C2 o O U) N o + A m Q N 246: 18" Basin - Circular Grate STA 11+25.30 w o N O TOP 445.15 90 n n � INV IN 438.87 (247) ^� o i I INV OUT 438.77 (245) o m m (n Z (n II II U1 A Z O o Cn rnODo° + O-UoF OJ o0 O A + 3 O V O -a � m O 403 0 + c 248: 12" Basin - Circular Grate CO 802: 15" Basin - Circular Grate STA 12+50.62 STA 10+16.38 TOP 444.00 TOP 451.69 INV OUT 439.50 (247) INV IN 446.43 (807) INV IN 446.43 (803) INV OUT 446.33 (801) w 0 0 + p O + O O 0 A O Cil V N + 0 0 400: ES-1 for 18 inch Pipe STA 10+00.00 O TOP 460.88 Cn INV IN 459.50 (401) 402: DI-3B 6 ft Throat STA 00 TOP 464.26 1 O INV IN 459.86 (403) O INV OUT 459.76 (401) <x�w mAO+ C; O n0�o �� D > 804: 15" Basin - Circular Grate < x ,rrn m STA 13+31.58 m 0 � QO TOP 466.71 x N O cn O INV IN 459.15 (805) oo (n O o O INV OUT 457.71 (803) y D I mm O II � ° o n + 404: DI-3B 6 ft Throat o N STA 11+92.12 CD o TOP 466.67 m O O INV IN 460.73 (405) INV OUT 460.63 (403)Ln CA Cn O + 0 0 406: DI-3B 6 ft Throat STA 13+28.88 TOP 465.26 + c" INV OUT 461.41 (405) 0 rn 0 o + A O V 0 U) 806: 15" Basin - Circular Grate 0 500: ES-1 for 15 inch Pipe STA 16+58.63 o STA 10+00.00 TOP 466.91 O 457.69 INV OUT 462.42 (805) 0 INVINN 456.03 (501) A O � Ft 502: DI-3C 6 it Throat o < x STA 10+37.36 O O TOP 462.69 XN INV IN 456.29 (503) on n INV OUT 456.19 (501) co i r �] + nn o U1 v, c'r O o o.p o mn 0 802: 15" Basin - Circular Grate 504: DI-36 6 ft Throat (n o STA 10+00.00 O STA 11+37.91 TOP 451.6. NOP 462.77 V OUT 456.89 (503) INV IN 446.43 (807) INV IN 446.43 (803) m OINV OUT 446.33 (801) N A N V + O < o O 00 O mA a A N VJ VJ CO CD V i r o+ < - m Tcn j O O< 7 N o A �_ -i Z cNi1 50 50 O D c O (j -i CO 00 A + ocri CD m m < x0 O o 600: ES-1 for 15 inch Pipe O -4 m m A STA 10+00.00 n � (n O TOP 460.88 00 INV IN 459.50 (601) mN 810: 15" Basin - Circular Grate m + STA 11+97.06 m " o �-t O o TOP 453.12 li li INV OUT 449.00 (809) v, o O 602: DI-3B 4 ft Throat N STA 10+54.40 TOP 463.06 A INV OUT 459.77 (601) rn + O A O • • Z T + UV1 O '1 O -I r �cnDcncncnZM m D71MMMMM zc�mcc�� �cnwcm= pD mm DmTI-U �00 -��m0°�Oz -ip� �G) o �0 D� vim m�� 0 Fn m o THIS DRAWING PREPARED AT THE CO •• CHARLOTTESVILLE OFFICE pub TIMMONS ROUP• • YOUR VISION ACHIEVED THROUGH OURS. y� n � 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903 y�9 �i; TEL 434.295.5624 FAX 434.295.8317 www.timmons.com O No q rt A DATE REVISION DESCRIPTION r O o ? 0= oo RIO POINT �N m �m o lo� r z CO o COUNTY OF ALBEMARLE, VA it m n o 2 m z N 1 FN� N w STORM PROFILES ti A N W I W A A (ASr CA71 N O N O N O tlt yQ s o A� O% � OA� DO omZ m0 m 0 � cNn to cW+, to o c�ir ocAir t o t o o can con 456.E �orn s'wo \ 00 �m o � 459.4 I 459.9 I � I IF� 460.5 � 1 1 \ O O O w W � m` 1 m v 461.5 m0,� 462.5 1 1 t 462.4 \ 463.E \ 468.7 \ 472.5 1 1 \ev V= J 473.0 � S c O � o �m� � I 471.8 469.0 J 466.4 A�m � V cps, cn o cn o v, o Cl)W A A VAi '(ASr OAi cn o cn o cn o 458.E 456.1 "' Z �C � ao o � 452.9 'T1 / / O 17 � � 449.0 m � � N C�Lr� O N = � O �o Z W� � O a A A o A A A A o cnA o cam+, W W A A 6A7�i cA7r O (T O CT O CT A w 0 \ m G7 v m O m 0 m � C� 0 o a N J \ \ N N \ O 11 \ � T \ p Z I m G� O m O O a W W A A rAJr rAJr O Cn O Cn O Cn A (ASr CA71 OAI � V Ul O CT O Cn O � f n v � O x �p 1}I 1 °mo � � N amo m t7 � m� o � J � 1 � om0 � +n A A A A A A cArr o c�i, o cot, o A A CA7r cA7r OA1 � o cn o cn o cn 458.5 amo 459.3 O� �`''= Om0 1 co 460.8 �� -G' p om O 1 mZ O A A CAir CAn O V7 O V7 O G1 A CAJi CA7i T T V cn o cn o cn o 460.3 t� (n A 1\ �x00 1I �$o 462.1 N jrj 3 � m z �� o0 m G> m cn O c�ii O Cott O O These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express wdtten consent of TIMMONS GROUP. STORM STRUCTURE TABLE STRUCTURE # TOP STRUCTURE HEIGHT DESCRIPTION 200 416.85 426.08' ES-1 for 36 inch Pipe 202 429.07 10.90' MH-2 204 443.39 7.85' MH-2 206 458.47 16.30' 24 x 24 inch Rectangular Structure 208 459.11 7.93' DI-3B 6 ft Throat 210 459.98 7.54' DI-3B 6 ft Throat 212 461.42 7.83' DI-3B 4 It Throat 214 460.51 4.48' DI-3B 6 It Throat 216 460.96 4.53' DI-3B 6 It Throat 218 464.97 4.44' DI-3B 6 ft Throat 220 467.98 4.11' DI-3B 4 It Throat 222 459.04 5.20' DI-3B 6 ft Throat 224 448.20 17.03' Cylinder 226 461.28 14.21' DI-3B 6 It Throat 228 460.92 11.19' DI-3B 6 ft Throat 230 460.50 9.89' 24" Basin - Circular Grate 232 460.32 7.46' DI-3B 6 It Throat 234 462.36 7.43' DI-3B 6 ft Throat 236 463.41 7.65' DI-3B 6 ft Throat 238 465.53 5.19' DI-3B 6 ft Throat 240 468.84 4.84' DI-3B 6 It Throat 242 462.73 5.06' 15" Basin - Circular Grate 244 464.06 4.06' 15" Basin - Circular Grate 246 445.15 6.38' 18" Basin - Circular Grate 248 444.00 4.50' 12" Basin - Circular Grate 250 456.00 6.67' 24" Basin - Circular Grate 252 462.52 11.68' 24" Basin - Circular Grate 254 461.00 7.76' 24" Basin - Circular Grate 256 459.54 8.87' DI-3A 258 456.00 4.56' 12" Basin - Circular Grate STORM STRUCTURE TABLE STRUCTURE # TOP STRUCTURE HEIGHT DESCRIPTION 100 414.86 425.37' EW-2 - 48" Pipe - 2:1 Fill Slope 102 418.00 7.82' Cylinder STORM STRUCTURE TABLE STRUCTURE # TOP STRUCTURE HEIGHT DESCRIPTION 300 414.38 435.03' ES-1 for 18 inch Pipe 302 453.81 14.73' DI-3B 4 It Throat STORM STRUCTURE TABLE STRUCTURE # TOP STRUCTURE HEIGHT DESCRIPTION 400 460.88 467.64' ES-1 for 18 inch Pipe 402 464.26 4.63' DI-3B 6 It Throat 404 466.67 6.20' DI-3B 6 It Throat 406 465.26 3.85' DI-3B 6 It Throat STORM STRUCTURE TABLE STRUCTURE # TOP STRUCTURE HEIGHT DESCRIPTION 500 457.69 ES-1 for 15 inch Pipe 502 462.69 6.67' DI-3C 6 It Throat 504 462.77 6.05' DI-3B 6 It Throat STORM STRUCTURE TABLE STRUCTURE # TOP STRUCTURE HEIGHT DESCRIPTION 600 460.88 ES-1 for 15 inch Pipe 602 463.06 3.41' DI-3B 4 It Throat STORM STRUCTURE TABLE STRUCTURE # TOP STRUCTURE HEIGHT DESCRIPTION 700 441.17 3.67' ES-1 for 18 inch Pipe 702 446.00 4.67' 24" Basin - Circular Grate STORM STRUCTURE TABLE STRUCTURE # TOP STRUCTURE HEIGHT DESCRIPTION 800 447.67 ES-1 for 18 inch Pipe 802 451.69 5.36' 15" Basin - Circular Grate 804 466.71 9.00' 15" Basin - Circular Grate 806 466.91 4.49' 15" Basin - Circular Grate 808 455.67 7.29' 15" Basin - Circular Grate 810 453.12 4.12' 15" Basin - Circular Grate STORM PIPE TABLE PIPE # DIA FROM - TO UPSTREAM INVERT DOWNSTREAM INVERT SLOPE LENGTH DESCRIPTION 101 48" 102 - 100 410.74 409.53 1.00% 120.62 LF 48 inch RCP STORM PIPE TABLE PIPE # DIA FROM - TO UPSTREAM DOWNSTREAMINVERT INVERT SLOPE LENGTH DESCRIPTION 201 36" 202 - 200 418.42 413.60 8.18% 59.01 LF 36" HDPE 203 30" 204 - 202 435.79 419.30 4.19% 393.56 LF 30" HDPE 205 24" 206 - 204 442.34 436.29 15.00% 40.31 LF 24" HDPE 207 24" 208 - 206 451.18 450.71 1.00% 47.25 LF 24" HDPE 209 24" 210 - 208 452.44 451.28 1.00% 116.82 LF 24" HDPE 211 18" 212 - 210 453.76 452.44 1.00% 131.67 LF 18" HDPE 213 18" 214 - 212 456.20 453.86 1.00% 234.12 LF 18" HDPE 215 15" 216 - 214 456.60 456.30 1.18% 25.46 LF 15" HDPE 217 15" 218 - 216 460.80 456.70 2.14% 191.78 LF 15" HDPE 219 15" 220 - 218 464.00 460.70 1.60% 206.10 LF 15" HDPE 221 15" 222 - 206 454.00 453.00 1.88% 53.25 LF 15" HDPE 223 36" 224 - 202 431.42 418.42 22.28% 58.37 LF 36" HDPE 225 30" 226 - 224 447.07 439.64 9.61 % 77.32 LF 30" HDPE 227 30" 228 - 226 449.90 447.50 2.60% 92.38 LF 30" HDPE 229 24" 230 - 228 450.78 450.00 1.00% 78.07 LF 24" HDPE 231 24" 232 - 230 452.86 450.87 2.63% 75.54 LF 24" HDPE 233 24" 234 - 232 454.93 452.96 1.00% 197.50 LF 24" HDPE 235 18" 236 - 234 455.76 455.03 1.00% 73.19 LF 18" HDPE 237 15" 238 - 236 460.51 455.86 2.69% 172.95 LF 15" HDPE 239 15" 240 - 238 464.17 460.61 2.01 % 177.08 LF 15" HDPE 241 15" 242 - 226 457.67 456.08 2.16% 73.51 LF 15" HDPE 243 15" 244 - 242 460.00 457.77 2.00% 111.29 LF 15" HDPE 245 15" 246 - 204 438.77 438.14 0.50% 125.30 LF 15" HDPE 247 15" 248 - 246 439.50 438.87 0.50% 125.32 LF 15" HDPE 249 18" 250 - 224 449.50 432.17 13.45% 128.82 LF 18" HDPE 251 18" 252 - 250 450.96 449.60 1.61 % 84.48 LF 18" HDPE 253 18" 254 - 252 453.37 451.06 2.00% 115.28 LF 18" HDPE 255 15" 256 - 250 450.77 450.35 1.00% 42.08 LF 15" HDPE 257 15" 258 - 256 451.44 450.87 1.00% 56.92 LF 15" HDPE STORM PIPE TABLE PIPE # DIA FROM -TO UPSTREAM INVERT DOWNSTREAM INVERT SLOPE LENGTH DESCRIPTION 301 15" 302-300 439.24 413.00 15.00% 174.94 LF 18" HDPE STORM PIPE TABLE PIPE # DIA FROM - TO UPSTREAM DOWNSTREAMINVERT INVERT SLOPE LENGTH DESCRIPTION 401 15" 402 - 400 459.76 459.50 0.69% 37.71 LF 15" HDPE 403 15" 404 - 402 460.63 459.86 0.50% 154.42 LF 15" HDPE 405 15" 406 - 404 461.41 460.73 0.50% 136.76 LF 15" HDPE STORM PIPE TABLE PIPE# DIA FROM -TO UPSTREAM INVERT DOWNSTREAM INVERT SLOPE LENGTH DESCRIPTION 501 15" 502 - 500 456.19 456.03 0.44% 37.36 LF 15" HDPE 503 15" 504 - 502 456.89 456.29 0.59% 100.46 LF 15" HDPE STORM PIPE TABLE UPSTREAM DOWNSTREAM PIPE # DIA FROM - TO SLOPE LENGTH DESCRIPTION INVERT INVERT 601 15" 1 602 - 600 459.77 459.50 0.50% 54.40 LF 15" HDPE STORM PIPE TABLE PIPE# DIA FROM -TO UPSTREAM DOWNSTREAM SLOPE LENGTH DESCRIPTION INVERT INVERT 701 18" 702 - 700 441.50 439.50 5.66% 35.36 LF 18" HDPE STORM PIPE TABLE PIPE # DIA FROM - TO UPSTREAM DOWNSTREAMINVERT INVERT SLOPE LENGTH DESCRIPTION 801 18" 802 - 800 446.33 446.00 2.00% 16.38 LF 18" HDPE 803 15" 804 - 802 457.71 446.43 3.58% 315.20 LF 15" HDPE 805 15" 806 - 804 462.42 459.15 1.00% 327.05 LF 15" HDPE 807 15" 808 - 802 448.38 446.43 1.14% 170.81 LF 15" HDPE 809 15" 810 - 808 449.00 448.48 2.00% 26.25 LF 15" HDPE SANITARY STRUCTURE TABLE STRUCTURE # TOP STRUCTURE HEIGHT DESCRIPTION EX1 371.38 9.94' Cylinder 1 368.22 4.55' Cylinder 2 377.92 10.04' Cylinder 3 394.04 19.58' Cylinder 4 429.13 16.81' Cylinder 5 447.99 16.33' Cylinder 6 457.49 16.00' Cylinder 7 460.89 18.77' Cylinder 8 464.50 21.34' Cylinder 9 463.19 18.96' Cylinder 10 465.73 20.33' Cylinder 11 468.16 21.54' Cylinder 12 463.63 15.77' Cylinder 13 456.61 7.03' Cylinder 14 455.82 4.69' Cylinder 18 450.41 8.11' Cylinder 19 454.58 11.42' Cylinder 20 458.67 11.18' Cylinder 24 450.76 7.06' Cylinder 25 449.23 4.19' Cylinder 29 461.08 6.52' Cylinder aan [300: ES-1 for 18 inch Pipe STA 10+00.00 TOP 414.38 INV IN 413.00 (301) SANITARY PIPE TABLE PIPE NAME SIZE LENGTH SLOPE BEARING 14-13 8" 60.15 LF 2.23% N40 43' 43"W 13-12 8" 312.36 LF 0.50% N25" 02' 05"W 11-10 8" 209.60 LF 0.50% S66" 25' 59"W 9-8 8" 174.09 LF 0.50% N23" 34' 01 "W 8-7 8" 167.78 LF 0.50% S660 25' 59"W 7-6 8" 85.10 LF 0.50% N49" 53' 24"W 6-5 8" 88.52 LF 0.50% S660 34' 53"W 5-4 8" 301.95 LF 6.23% S66° 11' 13"W 4-3 8" 212.22 LF 11.00% S35" 56' 41"W 3-2 12" 219.39 LF 0.50% S18" 43' 55"1N 2-1 8" 267.94 LF 1.49% S270 58' 58"E 1-EX1 8" 31.04 LF 7.27% S45" 13' 57"W 29-9 8" 179.62 LF 0.73% N230 34' 01 "W 25-24 8" 229.66 LF 0.50% N230 34' 56"W 20-19 8" 285.51 LF 0.50% S660 25' 59"W 19-18 8" 131.76 LF 0.50% S65" 33' 48"W 18-6 8" 103.93 LF 0.56% S350 55' 26"W 24-5 8" 264.67 LF 0.99% N230 34' 56"W 10-9 8" 209.60 LF 0.50% S660 25' 59"W 12-11 8" 199.65 LF 0.50% N230 34' 01 "W 302: DI-3B 4 It Throat STA 11+74.94 TOP 453.81 INV OUT 439.24 (301) aan 455 _ 455 EXISTING GRADE 450 � ` 450 / 445 445 PROPOSED BADE 440 440 SL-1 435 435 430 430 425 O� 4 425 420 420 415 415 410 410 9+50 10+00 11+00 12+00 STR 300 - STR 302 13+00 0 50 PROFILE SCALE NOTES: • INLET SHAPING (IS-1) IS SPECIFIED FOR ALL STRUCTURES • SAFETY SLABS (SL-1) ARE SPECIFIED FOR STRUCTURES TALLER THAN 12-FEET 7� OFL.'i ,. JG U CRAIG W. J. KOTARSKI Lic. No. 0402048507 .�,.02-0�-22, n E 0 0 U N N C ¢ 0 > E w ° E Z LU a`3 a o (ifO L M QJ000 W J -N d N N N LU v X oQ �v U) _ N = U >Lq ¢m c a, O N � M a� OJ J am O oc t7 w H DATE 0210712022 DRAWN BY VAN NIEK DESIGNED BY J. DENKO CHECKED BY C. KOTARSKI SCALE 1 " = 50' w J m Q w 06 > w z_� I --I < U O w ^ m LL Q L O U C0 O U Q I- Z Q 06 G O t/) JOB NO. 46883 L HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 SHEET NO. C8.3