Loading...
HomeMy WebLinkAboutSUB201900058 Other 2022-04-04 (2)wng m('C ch') HW1C HW1B HW1A PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA 71'-11%' 12 - (0843) 43'-0" SPAN x 8'-93/e' RISE x 5'-11%" LONG PRECAST CONCRETE BRIDGE UNITS PLUS 11 JOINTS @ Y4"i PER JOINT DETAIL 324 Ow� � ul w a C 1 V y C1 C3 C4 C4 C4 C4 C4 C4 C4 C4 C3 C2 DATE I REVISION DESCRIPTION KEY PLAN C NTECK EPMsIIIIII Souinom uC www.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 800-338-1122 513-645-7000 513-645-7993 FAX �SPAU *-SERIES, FABRICATION DRAWING 0pP CAB �Ae HW2A HW2B 1 N YID Digitally signed by / P41ILIP '�, Philip A. Creamer Al y CRNo.45R Date:2022.03.10 Lie. No. 45345 _ `� 14:09:30-05'00' JJECTNo. SEp. No. DATE: 689029 010 3/10/2022 PLEASANT GREEN SUBDIVISION JMF "JCH CMECrcED: APPROVED: SPS PAC ALBEMARLE COUNTY, VIRGINIA SHEET NO S1 OF S� WEIGHT OF REQUIRED REINFORCEMENT = 302.5 LBS/FT CIRCUMFERENTIAL LONGITUDINAL HEET AREA REQ'D AREA REQ'D NO (INWT) (INWT) 1 A1A=0.96 0.13 2 Al8=0.24 0.13 3 A2=0.48 0.13 4 A3 = 0.48 0.13 5 A4 = 0.48 0.13 6 DESIGN LOADING: HL-93 u a,,..°e °e,pinrram °,hy „n Eylnr,r.J sohnlma uc,.d echosnip nr. re..t ro „m:°�'Pm �IMARKI DATE PRECAST UNIT REINFORCEMENT LENGTH CIRCUMFERENTIAL LONGITUDINAL MESH SIZE (FT) AREA SUPUD AREA SUPUD (IN'/FT) (IN'/FT) 31'-0" 23'-0" 10'-9" 175" 20'-0" REVISION DESCRIPTION 28° B1 WEIGHT OF REQUIRED BAR REINFORCEMENT= 27.39 LBS/UNIT MARK SIZE NO. LENGTH TYPE Fy=60 KSI COVER = 2'-0" MIN. \ F-6" MAX. 1 61 1 #4 24 1'-8Yj" BENT I SPACED Q 6" O.C. NTEC rr0P� 8pAJI%L ENCIINELUD SOMO S uc O- ES www.ContechES.conn 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 FABRICATION 800-338-1122 513615-7000 513 6457993 FAX DRUiOMNc INCREMENTAL ARCH LEG THICKNESSES NOTES: 1. MINIMUM 28-DAY CONCRETE COMPRESSIVE STRENGTH SHALL BE 6000 PSI. 2. OVERLAP LENGTH SHALL BE MEASURED FROM LAST CROSSWIRE. 3. DIMENSIONS SHOWN ARE FOR FORM SYSTEM 0-800 SERIES. 4. MINIMUM YIELD STRENGTH FOR WELDED WIRE FABRIC SHALL BE 65,000 PSI. 5. REINFORCING SHALL BE LIMITED TO A MAXIMUM OF THREE LAYERS OF REINFORCING (WWF OR BARS) PER AREA (Al, A2, A3 OR A4). 6. ALL EDGES OF PRECAST TO HAVE A%" CHAMFER. 7. SPACING OF LONGITUDINAL REINFORCEMENT MUST BE A MAXIMUM OF 8" O.C. FOR MULTIPLE LAYERS OF MESH, ONLY THE OUTER MOST LAYER (A1A OR A3A) MUST BE A MAXIMUM OF 8" O.C. 8. SPACINGOFA2&A4 CIRCUMFERENTIAL REINFORCEMENT SHALL BE 2" MIN. TO 4" MAX. SPACING OF Al & A3 CIRCUMFERENTIAL REINFORCEMENT SHALL BE 2". PII£LIP �/ Digitally signed by w Philip A. Creamer Li,. No. 45345 453 Date- 2022.03.10 _,�� 14:09:41-05'00' PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA QIECT No.: SEM No.: DATE: 689028 1 010 3/10/2022 sIMED: DRAM: JMF JCH ECKED: APPROVED: SIPS PAC OF NOTES: -ALL EDGES OF PRECAST TO HAVE A %" CHAMFER - SEE SHEET S2 FOR BRIDGE UNIT DIMENSIONS - INSTALL TIE RODS BEFORE UNIT IS SET %-0 FERRULE LOOP INSERT (TYP.) UPRIGHT & LEAVE IN PLACE UNTIL UNIT IS SEE SECTION 11 ON SHEET S10 GROUTED INTO FINAL POSITION N I I I I I N I T. 1r n 4 I (T-6" T-0" (T-2t/z' ALONG T/ARCH) ALONG T/ARCH) m m f! F-58 INSERTS fE1"0 HOLE LIFT INSERT (TYP.) FOR TIE ROD FLS" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR(TYP.) 4142 6 54 S7 PLAN -C1 &C2 TOTAL WEIGHT = 24.5 TONS 43'-1Y2" 40'-8 4" 1'-25/g' 22W 4:10p DENOTES REFERENCE POINT PROVIDE EDGE LIFT POINTS FOR N e, CL 1"1 HOLE FOR TIE ROD FOR LOADING UNIT ON TRAILER Y HANDLING UNIT ON ITS SIDE e �� /Y II 3T x 3P.) BLOCKOU(TYP.) o �+ ` Digitally signed ELEVATION `;��'' i �r. by Philip A. rfiI�,ir tiAM Creamer CR.Ld6SiiR Lie. No.45345 Date: 2022.03.10 14:09:54-05'00' &,re,s�� ,o..,.�.,'r_ rea; 6 1'- 'Y� lea`\se�ww■ PROJE902 SEO 1 DAIS 688029 010 3/10/2022 n°'".,i° a. .°v wn me,th. m.v m °..e. ,.°,°aura °, oo°°°.el,I C NTECH• /// YYYiii��i�\l\Yl i��/y�Y. O- ES PLEASANT GREEN SUBDIVISION DESIGNED DnA�n JMF JCH r. ,..i....,m..°,,,e"„ Er�INEUMSOLunaNSuc m�.0 l .. 'x °°'�-d"°1°�;�"u;m w .ContechES.conn CHECKED: APPROVEo: SPS PAC o"M '".N..�°'p n 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 .,. .00y._ e.ay�. e..m an , �,q.i.a """"°'°°""'"°"°"°" 800-338-1122 513-fi45-T000 513-fi45-1993 FAX FABRICATION DRAWING ALBEMARLE COUNTY, VIRGINIA SNEETNo.. MARK DATE REVISION DESCRIPTION BY S3 Or S26` 0 0 0 47'-8" 11'-4"HEADWALL-HWIA- - 24'-11"HEADWALL-HW1B- 6" 1/p" JOINT 5 - #6 BARS EACH FACE 11 - TIES (SPACE AS SHOWN) (SPACE AS 34 - TIES (SPACE AS SHOWN) SHOWN) 5" 14 - SPACES Q 8" 31 - SPACES @ 8" 8" 3'-B%" 3'S" 8" HEADWALL ARCH UNIT CONCRETE REINF. STEEL CONCRETE REINF. STEEL W✓JF 28-DAY: 4000 PSI W,000 PSI UNCOATED 28-DAY 5000 PSI 1 60,000 PSI UNCOATED 1 65,000 PSI UNCOATED WHEREVER THE REINFORCING IS CUT FOR THE PLACEMENT OF LIFT HOLES OR OTHER BLOCKOUTS, REINFORCING BARS OR HARES OF EQUIVALENT CROSS -SECTIONAL AREA SHALL BE PLACED SYMMETRICALLY AROUND THE HOLE. AT LEAST ONE BAR MUST BE ON EACH SIDE OF THE HOLE, AND THE DEVELOPMENT LENGTH OF THE BAR MUST BE ACHIEVED ON EITHER SIDE OF THE CUT. —11'-4" HEADWALL - HW1 C 6" JOINT 11 - TIES 5 - #6 BARS EACH FACE SHOWN)) —(SPACE (SPACE AS SHOWN) 14-SPACES rQ 9" 5" 2" CLR. (TYP.) #6 EACH FACE rQ 1'-0" O.C. MAX. WI 7I'I,I I a, ^ 1 11 111 �� ••�'-I -1 -I fi--7--'TT T I � � L onto rn ur 'urmaaaan.n iN iN 7't tj-ttLl��}-'� _T_TT 1TtT ri r r�firj 1 fir 1 fi�-TfiN $ n LLITTT_I tn� I� ITT ITt 11 LI ICI rI IT�1T7� ITrt m TI 1TT� ITtT11 \ I ICI T r1 1T-1 _ —T T j IT T ITtT11 �� (> — 1 ,vPT T ITS R 1_ L L, T� T I-T 3 0 T % F 0 4 8- HEADWALL S^ / ,�.5 .nN CONNECTIONS PJ 7j T Q 2'$" O.C. (TYP.) Y rL%"O x 6" FERRULE LOOP INSERT W/s/a'0 THREADED ROD & , rn- m TAPERED STEEL PLUG. (TYP.) 2 - HEADWALL SEE SECTION 11 ON SHEET S10 CONNECTIONS 1.�,. 4Z-15" O.C. (TYP.)6" DAYTON SUPERIOR TWO 1�(0843) 43'-0"SPAN N ro BOLT PRESET ANCHOR (TYP.) ELEVATION 2 3w UNIT CI S3 yra,l: y: IN"..'a ' �'4d,,� IN.b ^romm.om m. Pmd.......mmm^. re.1y ai.eam..,y a miry o, meo.. b,1V ro anngl 1.x d�.... I.1d. 4Nm..re up,,�Y� a ob"sre..... m. .,,m..�r��u�e^Ke.eu-"m..s�—I— FMARKVDATE REVISION DESCRIPTION 0`111111.414-1 EPWIMEMD S0113i OM QC W W W.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 800-338-1122 513615-7000 513 645-799 FAX =N�SPAL O-SERIES.. FABRICATION DRAWING NOTES: -ALL EDGES OF PRECAST TO HAVE A %" CHAMFER - ELEVATION IS LOOKING AT BACK FACE OF HEADWALL - SEE SHEET S3 FOR BRIDGE UNIT C.G. & LIFT POINTS - SEE SHEET S5 & S6 FOR HEADWALL C.G. & LIFT POINTS - HEADWALL TO BE CAST AGAINST BRIDGE UNIT - BRIDGE UNITS MUST BE GROUTED OR BRACED WHEN SETTING PRECAST HEADWALLS - SEE SHEET S2 FOR BRIDGE UNIT DIMENSIONS - INSTALL TIE RODS BEFORE UNIT IS SET UPRIGHT & LEAVE IN PLACE UNTIL UNIT IS GROUTED INTO FINAL POSITION Digitally signed by rAL ALAN Philip A. Creamer CREAMER Date:2022.03.10 Lic. No. 45345 �. 14:10:13-05'00' .ct PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA QIECT No.: 689028 1 010 3/10/2022 SIGNED: DM M: JMF JCH ECKED: APPROVED: SPS PAC OF rLTOP LIFT POINTS ILTOP LIFT POINTS NOTES: - ALL EDGES OF PRECAST TO HAVE A 31," CHAMFER (MUST BE CAPABLE OF (MUST BE CAPABLE OF - ELEVATION IS LOOKING AT BACK FACE OF SUPPORTING ENTIRE SUPPORTING ENTIRE HEADWALL IL6" DAYTON SUPERIOR TWO WEIGHT OF HEADWALL) WEIGHT OF HEADWALL) - HEADWALL TO BE CAST AGAINST BRIDGE UNIT BRI GE UNITS MUST BE GROUTED OR BOLT PRESET ANCHOR 11'4" (7 a0 HWHEN EADWALL SETTING PRECAST HANG LEVEL. ADJUST BRACED 4'-103 XU 24 11 _ U �8 - -HEADWALL WILL NOT HANG LEVEL. ADJUST O o 12'-11" CABLE LENGTHS AS REQUIRED � I I rL4"W x 1Y,"D x 1'-10" LONG FL5 - 3"0 HOLES rL10 - 3"0 HOLES BLOCKOU7 FOR TIE RODS PLAN - HW1A PLAN - HW1 B TOTAL WEIGHT = 6.9 TONS TOTAL WEIGHT = 9.3 TONS rL LIFT POINTS (TOP 2 LIFT LIFT POINTS OP 2 LIFT POINTS MUST BE CAPABLE IL (7 OF SUPPORTING ENTIRE POINTS MUST BE CAPABLE WEIGHT OF HEADWALL) OF SUPPORTING ENTIRE 24• 11" IL6" DAYTON SUPERIOR TWO WEIGHT OF HEADWALL) - N 12-11" BOLT PRESET ANCHOR (7YP.) 11 ro 77 C.G. ry m C.G. \ ! N fLTAPERED STEEL PLUG 1�, \\ W/ 1"0 PVC. SEE s 5 - 3"O HOLES n Pei @2'$"OC (7YP) SECTION 11 ON SHEET S10 o N 0 1 ILTAPERED STEEL PLUG (� rL4" x 4" x 2" DEEP n A W/1"O PVC. SEE ELEVATION q BLOCKOUT(7YP.) n p; SECTION 11 ON SHEET S10 r� 3 - 370 HOLES @ 2'-6" O.C. �p 2-3"0 HOLES @ 2'-6" O.C. 4'W x 1Y,"D x 1'-10" LONG M1 1'-6Y"+--�i ^ BLOCKOUT FOR TIE RODS _r. AL7fi0. ELEVATION r3 Digitally signed by c- 7 PHILIP ALAN y� Philip A. Creamer ALAN, `gyo"LR Lie. No. 4534Date: 2022.03.1 • 5 c 14:10:32-05'00' n rvgn�"nomm----..m rvr.— ��.�..��\ PRQIECT11- SEMNo.: DATE: w 689029 010 3/10/2022 aro: C NTECH' / =Y \SP�" DESIGNED : DRAWN: °,mm.°°=, •,tn°m m. P,m„.wn.°.°°..mm PLEASANT GREEN SUBDIVISION -1y.....m,.°,l,e,no,—°°°"Dr„� "l .. 1EMINEERIMSO iOMQC `y}L 7IiC� JMF JCH www.ContechES.com CHECKED: APPROVED: ""°° ix°' °°' "M"' ° "u; 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45W9 FABRICATION 'Ell SPS PAC g'o u' 1°�; m °"°"°" 800-338-1122 5136t5-7000 513645-7993 FAX SHEET NO.: e•.ea�m�=•re,^�w.�.� Nc ALBEMARLE COUNTY, VIRGINIA ew ten.,.. MARK DATE REVISION DESCRIPTION BV SS °F SZB wry - '.-N—,,M: , ,rem u arol:,wyd�—� ..a l N.b�o. .�mom m. p,m,„ d.......m m M.ly m,e.i--yb b,,t, o, -p.., b,1V ro anngl —1.x d....I hld �v d4 —.re u,rca'�'Y� a byb.. rbbycb �� u�e"Kb-d-".1-, —1—w FMARKVDATF REVISION DESCRIPTION rLTOP LIFT POINTS (MUST BE CAPABLE OF SUPPORTING ENTIRE WEIGHT OF HEADWALL) (7 o0 �O IL5 - 3"0 HOLES IL6" DAYTON SUPERIOR TWO <' BOLT PRESET ANCHOR F1T-0- 0%" ?e o �I o- PLAN - HW1C TOTAL WEIGHT = 8.3 TONS rLLIFT POINTS (TOP 2 LIFT POINTS MUST BE CAPABLE OF SUPPORTING ENTIRE WEIGHT OF HEADWALL) T-0" ILTAPERED STEEL PLUG W/ 1"0 PVC. SEE SECTION 11 ON SHEET S10 ?y 3 - 3"0 HOLESJ�' Q 2'-6" O.C. 2 - 370 HOLES _ Q 2'-6" O.C. 4"W x iy"D x 1'-10" LONG BLOCKOUT FOR TIE RODS ELEVATION 5 0`1111-414-1 EPWIMEHII), SOUMOM QC Www.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45W9 800-338-1122 513615-7000 513 645-799 FAX m (LW W x %"D x 1'-10" LONG BLOCKOUT FOR TIE RODS IL6- DAYTON SUPERIOR TWO BOLT PRESET ANCHOR(TYP.) =W�SPAL O-SERIES.. FABRICATION DRAWING NOTES: - ALL EDGES OF PRECAST TO HAVE A %" CHAMFER - ELEVATION IS LOOKING AT BACK FACE OF HEADWALL - HEADWALL TO BE CAST AGAINST BRIDGE UNIT - BRIDGE UNITS MUST BE GROUTED OR BRACED WHEN SETTING PRECAST HEADWALLS - HEADWALL WILL NOT HANG LEVEL. ADJUST CABLE LENGTHS AS REQUIRED Digitally signed by T'" P APhilip A. Creamer CREy ER Lie. NNo. 5345 Date: 2022.03.10 o. 4 Af _.� 14:10:46-05'00' PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA QIECT No.: 689028 1 010 3/10/2022 SIGNED: DRAM: JMF JCH ECKED: APPROVED: SPS PAC OF 11'<" HEADWALL- HW7Z 6" 5 - #6 BARS EACH FACE F, 11 -TIES (SPACE AS SHOWN) (SPACE A; SHOWN) $" -ES @9"- 3'-8%" N b b+ F F n nlro ro to n yI yI rl rr�fiT j T--T-T TIT T T -11- IT t 1-t TIT T T i IT t 10 T1T T T T T i IT t 110 1-1�Ttj Intl N IT r-Itl 1 T1 TT j I I � 46" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR (TYP.) '""'" '_"IMARKI DATE I REVISION DESCRIPTION Y �I 24'-11" HEADWALL- JOINT 34-TIES (SPACE AS SHOWN) 31 - SPACES @ 9" 8" 5_1" HEADWALL ARCH UNIT CONCRETE REINF. STEEL CONCRETE REINF. STEEL W✓JF 28-DAY: 4000 PSI 60,000 PSI UNCOATED 28-DAY: 5000 PSI 60,000 PSI UNCOATED 65,000 PSI UNCOATED WHEREVER THE REINFORCING IS CUT FOR THE PLACEMENT OF LIFT HOLES OR OTHER BLOCKOUTS, REINFORCING BARS OR HARES OF EQUIVALENT CROSS -SECTIONAL AREA SHALL BE PLACED SYMMETRICALLY AROUND THE HOLE. AT LEAST ONE BAR MUST BE ON EACH SIDE OF THE HOLE, AND THE DEVELOPMENT LENGTH OF THE BAR MUST BE ACHIEVED ON EITHER SIDE OF THE CUT. 11'<"HEADWALL-HW2C 6" 6" 1/p" JOINT 11 -TIES 5-#6 BARS EACH FACE (SPACE (SPACE AS SHOWN) SHOWN)) 14 - SPACES @ 9" 5" 8„ 2" CUR. (TYP.) 6'-0" fr 96 EACH FACE @ t!� 1'-0" O.C. MAX. R T H 4-1--LP__L L I_I I I I_I __L ��U �N�LI�ILLI_I I I_ILtt-TTl l-+t 4�LJ �N� lel I_I �tl—ITTFI_It -1 - L L 1 �P. (TYP.) N 8-HEADWALL CONNECTIONS m @ 2'$' O.C. (TYP.) rL%"Ox 6" FERRULE LOOP INSERT W/ s/a O THREADED ROD & TAPERED STEEL PLUG. (TYP.) SEE SECTION 11 ON SHEET S10 (0843) 43'-0" SPAN ELEVATION 6 UNIT C2 S3 CNTECH' ENGIPIEEMD S0113i OM QC W s W.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 800-338-1122 513615-7000 513 645-7993 FAX =W�SPAL O-SERIES.. FABRICATION DRAWING TI� T TIt T T t-- 1_t + tG TI�tTI�TT Irt+t- TIC T Tlt T T IT + r TI�tTI-tTT 1-1+t- T Tlt T T 1T + r I tTI 1-1+r T t�lrt 4 2-HEADWALL CONNECTIONS @ 2'-6" O.C. (TYP.) it % °t. pill J AT Ai CREAMER Lie. No. 45345 a PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA NOTES: -ALL EDGES OF PRECAST TO HAVE A Y4" CHAMFER - ELEVATION IS LOOKING AT BACK FACE OF HEADWALL - SEE SHEET S3 FOR BRIDGE UNIT C.G. & LIFT POINTS - SEE SHEET S8 & S9 FOR HEADWALL C.G. & LIFT POINTS - HEADWALL TO BE CAST AGAINST BRIDGE UNIT - BRIDGE UNITS MUST BE GROUTED OR BRACED WHEN SETTING PRECAST HEADWALLS - SEE SHEET S2 FOR BRIDGE UNIT DIMENSIONS - INSTALL TIE RODS BEFORE UNIT IS SET UPRIGHT & LEAVE IN PLACE UNTIL UNIT IS GROUTED INTO FINAL POSITION Digitally signed by Philip A. Creamer Date: 2022.03.10 14:10:59-05'00' QIECTNo.: 689029 SEO.No.: DATE: 010 3/10/2022 SIGNED: DM M: JMF JCH ECKED: APPROVED: SPS PAC OF IL6" DAYTON SUPERIOR TWO _ BOLT PRESET ANCHOR i7 rL4"Wx%Y Dx 1'-1W LONG BLOCKOUT FOR TIE RODS IL6" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR(T/P.) a a FLTOP LIFT POINTS (MUST BE CAPABLE OF SUPPORTING ENTIRE WEIGHT OF HEADWALL) 1 /e L IL5-3"0 HOLES PLAN - HW2A TOTAL WEIGHT = 8.2 TONS FLLIFT POINTS (TOP 2 LIFT POINTS MUST BE CAPABLE OF SUPPORTING ENTIRE WEIGHT OF HEADWALL) C.G. Y fLTAPERED STEEL PLUG W/ 1"O PVC. SEE -� SECTION 11 ON SHEET S10 3 - 370 HOLES @ 2'-6" O.C. _ 2-3"0 HOLES @ 2'-6" O.C. 4'W x 1Y,"D x 1'-10" LONG BLOCKOUT FOR TIE RODS ELEVATION 7 L9-I I C.G.— m �? PLAN - HW213 TOTAL WEIGHT = 11.4 TONS a fLTAPERED STEEL PLUG 3s�e 5 - 3"0 HOLES W/ 1 "0 PVC. SEE 1l.`yp) @ 2'$" D.C. (TYP) SECTION 11 ON SHEET S10 ELEVATION e FLTOP LIFT POINTS (MUST BE CAPABLE OF SUPPORTING ENTIRE WEIGHT OF HEADWALL) - U' N n O e IL10 - 3"0 HOLES rLLIFT POINTS (TOP 2 LIFT POINTS MUST BE CAPABLE OF SUPPORTING ENTIRE WEIGHT OF HEADWALL) rL4"x4"x2"DEEP BLOCKOUT(TYP.) NOTES: - ALL EDGES OF PRECAST TO HAVE A %" CHAMFER - ELEVATION IS LOOKING AT BACK FACE OF HEADWALL - HEADWALL TO BE CAST AGAINST BRIDGE UNIT - BRIDGE UNITS MUST BE GROUTED OR BRACED WHEN SETTING PRECAST HEADWALLS - HEADWALL WILL NOT HANG LEVEL. ADJUST CABLE LENGTHS AS REQUIRED Digitally signed 9 � Y by ALAN Philip A. Creamer ALAN y;• CRBAIIL" Lic. ND.'Z45 Q <� 14:11:11-05'00' n rvpn�,no mormav°n ancm mmv m rvp.— PROJECT No.: SEM No.: DATE: " ' `°A °%I'.U' `x re�� a m�.d..., --thy °,.a :p.°a °. 4 C NTECH' /=N�SP� 11 689029 010 3/10/2022 ° mt—C m. p,m„min.°.°°,.mmIG� PLEASANT GREEN SUBDIVISION DesJONED: DRavm: mm„m,wmm„°,I,b,l, ;r ,p°°,Dr„ ,l , eNGINEERMSOWTIOMILC JMF JCH "°,mm,°°e,.pn°m w .ContechES.com CHECKED: APPROVED: ""°, g'o ix°' °°' 1°�; "u; m "m"' ° SPS PAC u' """"'°-.—,"°"°" 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45W9 FABRICATION SHEET NO.: .®Pa°°rm�r„m, anpm e,,,am m�,.°p, �,.mmw.l.m 800-338-1122 5136iS7000 513E4S7993 FAX oanwJNc ALBEMARLE COUNTY, VIRGINIA °„remmm, m,:°p �m ew mn,�,. MARK DATE REVISION DESCRIPTION BY SH °F SZB yr .p,,1_..ro.�rea,6 u"a. . o.n�re,eo�. m.y.-. ,,.p.d—o, uu re., I....im..or r emryo re.eu..e.bip ro ou"sre..... m ., .b.b.. ��e e"Ke.u� "mp.reFMARKFDATe REVISION DESCRIPTION rLTOP LIFT POINTS (MUST BE CAPABLE OF SUPPORTING ENTIRE WEIGHT OF HEADWALL) - d . 0 rn O IL5 - 3"0 HOLES 4'-11s/4" 3'-0" 3'-0"+f HOWA PLAN - HW2C TOTAL WEIGHT = 9.0 TONS rLLIFT POINTS (TOP 2 LIFT POINTS MUST BE CAPABLE OF SUPPORTING ENTIRE WEIGHT OF HEADWALL) —1 V-4" -ti�;4 �} i ILTAPERED STEEL PLUG W/ 1"0 PVC. SEE SECTION 11 ON SHEET S10 ?y 3 - 3"0 HOLES Q 2'-6" O.C. 2 - 370 HOLES _ Q 2'-6" O.C. 4"W x 1Y"D x 1'-10" LONG BLOCKOUT FOR TIE RODS ELEVATION s 0`1111-414-1 EPWIMEHII), SOUMOM QC Www.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45W9 800-338-1122 513615-7000 513 645-799 FAX _ IL6" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR m (L4"W x 1Y,"D x 1'-10" LONG BLOCKOUT FOR TIE RODS IL6" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR(TYP.) W m '-6Yz" IIIXIIN�SPAL O-SERIES.. FABRICATION DRAWING NOTES: - ALL EDGES OF PRECAST TO HAVE A %" CHAMFER - ELEVATION IS LOOKING AT BACK FACE OF HEADWALL - HEADWALL TO BE CAST AGAINST BRIDGE UNIT - BRIDGE UNITS MUST BE GROUTED OR BRACED WHEN SETTING PRECAST HEADWALLS - HEADWALL WILL NOT HANG LEVEL. ADJUST CABLE LENGTHS AS REQUIRED r lPDigitally signed by ALAN �,, Philip A. Creamer CRNo.45R Lie. No. 45345 e f Date: 2022.03.10 _.Clw 14:11:28-05'00' PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA QIECT No.: 689028 1 010 3/10/2022 sIDNED: DRAM: JMF JCH ECKED: APPROVED: SPS PAC OF arol: wyd�—� ..al:o.".�". .mom m. P•m•� d.".....mm M.ly m.e.i--y li b,,t, o, -p... b,1V ro anngl 1bdI .x .....1d—dN—.re .rca "Y�� a byb.. rbbycb �� u�e"Kb-d-".1-, —1—w FMARKVDATE REVISION DESCRIPTION 2" CLR. (TYP.) #6 EACH FACE _ @ 1'-0" O.C. MAX. 1Y-," x 3Ya" KEYWAY PRECAST _ BRIDGE UNIT 6 - 05 @ 4 2 O.C. (MATCH LENGTH OF Al OR A1A MESH ON SHEET S2) rLDAYTON SUPERIOR %"0 x 7Ya" F-58 EC INSERT (STAINLESS) 1Y4.0 x 1'$" COIL ROD (STAINLESS) DOUBLE NUT (STAINLESS) WASHER (PW-2) (GALVANIZED) 6" 91, O.C. VARIES 2'-8" - #5 @ 9" O.C. g^ �2-#6 TOP &BOTTOM 3"0 HOLE GROUT SOLID IN FIELD AFTER INSTALLATION OF COIL ROD NOTE' FORM VOID AS REQUIRED FOR COIL -1" PENETRATION (MIN. 2y" FROM TOP OF INSERT) L ADD #6 @ 8" (OR EQUIV.) TO TRANSVERSE REINFORCEMENT /\ 6-6"•�.{ IN END BRIDGE UNITS SECTION 10 sa,37 6•• W IY j o I REINFORCING NOT SHOWN FOR CLARITY 1"O x9"PVC 1Y", WO THREADED ROD 8'II TAPERED STEEL PLUG 1"O HOLE THRU PLUG 2• a%"0x6"FERRULE LOOPINSERT SECTION ,1 sa,s7 CNTECH' EPWIMEHII), S0113i OM QC Www.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45W9 800-338-1122 513615-7000 513 645-799 FAX =N�SPAL O-SERIES.. FABRICATION DRAWING 1%"0 HOLE M PW-2 (R WASHER, Y," x 4" x 4') (GALVANIZED AS PER ASTM A123) PHILIP ALAN CREAMER Lic. No. 45345 PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA Digitally signed by Philip A. Creamer Date: 2022.03.10 14:11:43-05'00' QIECT No.: 689028 1 010 3/10/2022 SIGNED: DRAM: JMF JCH ECKED: APPROVED: SPS PAC OF IL VO HOLE FOR TIE ROD 1�25�" — � — — — — T 6 � (T 2t/z ALONGG TI T/ARCH) ALONG T/ARCH) REINFORCING BLOCKOUT (TYP.) SEE SHEET S24 FOR MORE INFORMATION —T- 1 C.G. 12 PLAN - C3 TOTAL WEIGHT = 24.5 TONS 4D'-SY;' m DENOTES REFERENCE POINT v FOR LOADING UNIT ON TRAILER Y kii�m 1 ry ELEVATION 2 4-6"�i Tr LIFT INSERT (TYP.) (0843) 4T-0" SPAN x 8'-9s/e' RISE PRECAST BRIDGE UNIT PROVIDE EDGE LIFT POINTS FOR HANDLING UNIT ON ITS SIDE Wx3V BLOCKOUT (TYP.) TL1"0 HOLE FOR TIE ROD NOTES: -ALL EDGES OF PRECAST TO HAVE A %" CHAMFER - SEE SHEET S2 FOR BRIDGE UNIT DIMENSIONS - INSTALL TIE RODS BEFORE UNIT IS SET UPRIGHT & LEAVE IN PLACE UNTIL UNIT IS GROUTED INTO FINAL POSITION - MANUFACTURER SHALL MARK END OF UNIT C3 WITH REINFORCING BLOCKOUT PRIOR TO SHIPPING. ARCH UNIT CONCRETE REINF. STEEL WWF 28-DAY: 6000 PSI 60,000 PSI UNCOATED 65,000 PSI UNCOATED WHEREVER THE REINFORCING IS CUT FOR THE PLACEMENT OF LIFT HOLES OR OTHER BLOCKOUTS, REINFORCING BARS OR WIRES OF EQUIVALENT CROSS -SECTIONAL AREA SHALL BE PLACED SYMMETRICALLY AROUND THE HOLE. AT LEAST ONE BAR MUST BE ON EACH SIDE OF THE HOLE, AND THE DEVELOPMENT LENGTH OF THE BAR MUST BE ACHIEVED ON EITHER SIDE OF THE CUT. �Ilffl Digitally signed p,p by Philip A. "I CRHAbiFiR M Creamer Lic.No. 45345 Date: 2022.03.10 14:11:56-05'00' n rvpn�,no m°rmav°n--mym rvr.— ^ PROJECT No.: SEQ. No.: DATE: " ' `°' °�'1' `rmi re�� a aro: w e CNTECH' 7l0lr N SP� //7 ��Yy..L��iii..iii���»>lll i 688028 010 3/10/2022 m. n,m„min.°.°°,.mm C PLEASANT GREEN SUBDIVISION DESJONED: DRAWN: ,m. , �mlyd,d—,-.1e"�,@°°°•e1V" EN�INE�SOLUVIor�suc 7 IG� JMF JCH �°,m'm—mp1ym°m www.ContechES.com CHECKED: APPROVED: ""°,g'o ix°' °°'u'1-pp°�;"u; m"M"' ° SPS PAC """"'°°""'"°"°"°" 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45059 FABRICATION SHEET NO.: ,-"'m e,.,am m�..�,,�,w,�,m 800-338-1122 5136iS7000 513E4S7993 FAX DRAWJNG ALBEMARLE COUNTY, VIRGINIA p °„remmm m,:°n m ew mn,�,. MARK DATE REVISION DESCRIPTION BY S11 oP S26 4'-6" NOTES: -ALL EDGES OF PRECAST TO HAVE A %" CHAMFER - SEE SHEET S2 FOR BRIDGE UNIT DIMENSIONS - INSTALL TIE RODS BEFORE UNIT IS SET UPRIGHT & LEAVE IN PLACE UNTIL UNIT IS GROUTED INTO FINAL POSITION �j ARCH UNIT CONCRETE REINF. STEEL WWF 28-DAY: 6000 PSI 60,000 PSI UNCOATED 65,000 PSI UNCOATED T WHEREVER THE REINFORCING IS CUT FOR THE PLACEMENT OF LIFT HOLES OR OTHER BLOCKOUTS, REINFORCING BARS OR WIRES OF EQUIVALENT CROSS -SECTIONAL AREA SHALL BE PLACED SYMMETRICALLY AROUND THE HOLE. AT LEAST ONE BAR MUST BE ON EACH SIDE OF THE HOLE, AND THE r TrV T T I DEVELOPMENT LENGTH OF THE BAR MUST BE ACHIEVED ON EITHER SIDE OF THE CUT. IL O HOLE in LIFT INSERT (TYP.)^ FOR TIE ROD 13 PLAN - C4 TOTAL WEIGHT = 24.5 TONS 43'-1%' 1� 25�,' T-2lle 40'-St/4" (0843) 4T-0" SPAN x 8'-9s/e' RISE PRECAST BRIDGE UNIT 22W 10p DENOTES REFERENCE POINT FOR LOADING UNIT ON TRAILER Y PROVIDE EDGE LIFT POINTS FOR HANDLING UNIT ON ITS SIDE N TL1"0 HOLE —a FOR TIE ROD \m W x 3Ke" BLOCKOUT (TYP.) r ,� , Digitally signed ELEVATION 3 "' P ' by Philip A. PHILIP J L "i, Creamer CRE:1biL Lie. No. 45345 Date: 2022.03.10 14:12:09 -05'00' ...n no morm•von—mmym rvr.— '"A "'•a,_. PROJECT No.: I SEM No.: I DATE: reap- aro: w e:,� ao. CNTECH' /=N�SP� 688028 010 3/70/2022 ",mm.""e,.��nom m. n,m„m.n.".o...mm ���.a.�•m•.�.�,e,no,m,00••Dr„�° PLEASANT GREEN SUBDIVISION DESJDNED: DRavm: .m. .. eNCl��soiurlw+suc 0-SERIES.. JMF JCH CHECKED : SPS APPROVED: PAC ° ""°•"'"'�,'p ix°' °"'u'1­pp°�;"u; www.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45059 FABRICATION m"M"' f nm...o .,. m;m.:. - ....00�m��.a..rem�m�A 800338-1122 513-645-7000 513645-7993 FAX GHEE'"D.: m, any". m.m m m�:."y, �,.mmq.xm DRAWNG ALBEMARLE COUNTY, VIRGINIA •m&mom P . by, h.,. MARK DATE REVISION DESCRIPTION By S12 DE S26 FLLIFT POINTS (TOP 2 LIFT T-5" POINTS MUST BE CAPABLE 1 �" OF SUPPORTING ENTIRE 8' 1'-0" WEIGHT OF WINGWALL) r 4Yz" L14 �4— C I o II II v m - II II HH HH m N Hi 1 N I I III = 24 FLWALL ANCHOR WINGWALL - WW1A rLLIFT POINTS (TOP 2 LIFT POINTS MUST BE CAPABLE _ OF SUPPORTING ENTIRE WEIGHT OF WINGWALL) o 4'/s" ~ 15 n T T o 0 m ILWALL ANCHOR TOTAL WEIGHT = 4.7 TONS 3'-0" 1 T-9' 1'-0" L WINGWALL - WW1 B TOTAL WEIGHT = 8.5 TONS '""'" '—"IMARKI DATE I REVISION DESCRIPTION #4 @ T-6- O.C. EACH FACE, EACH WAY OR EQUIVALENT MESH VERTICAL BARS: 2-#4@3"0.C. BACK FACE ONLY 2" CUR. (TYP.) #4 x 10'-2" BACK FACE ONLY #5 EACH FACE (TYP. ALL EDGES) l VERTICAL BARS: 2-#4@3"O.C. BACK FACE ONLY VERTICAL STEEL AT ANCHOR TO BE 2" CUR. FROM BACK FACE OF WALL (TYP.) W = 3'-TYP B S.A,. TYPE B _< 0 REINFORCING DETAIL - WW1A (FOR ANCHOR REINFORCING SEE SHEET S20) I-LS" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR . p���'lll 11 .- � ijL.. I SECTION 4 NOTES: -ALL EDGES OF PRECAST TO HAVE AY4" CHAMFER - ELEVATION IS LOOKING AT BACK FACE OF WINGWALL - BACK FACE DENOTES ANCHOR SIDE OF WINGWALL - WINGWALL WILL NOT HANG LEVEL. ADJUST CABLE LENGTHS AS REQUIRED WINGWALL CONCRETE REINF. STEEL VJ✓JF 28-DAY: 4000 PSI 60,000 PSI UNCOATED 65,000 PSI UNCOATED WHEREVER THE REINFORCING IS CUT FOR THE PLACEMENT OF LIFT HOLES OR OTHER BLOCKOUTS, REINFORCING BARS OR WIRES OF EQUIVALENT CROSS -SECTIONAL AREA SHALL BE PLACED SYMMETRICALLY AROUND THE HOLE. AT LEAST ONE BAR MUST BE ON EACH SIDE OF THE HOLE, AND THE DEVELOPMENT LENGTH OF THE BAR MUST BE ACHIEVED ON EITHER SIDE OF THE CUT. r 4y. L8" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR 'II.If ...��J 1 L ' SECTION ,5 " Y2" THICK EXPANSION BOARD PAD ATTACHED TO WINGWALL WITH #5 EACH FACE CONSTRUCTION ADHESIVE (TYP.) (TYP. ALL EDGES) #4 @ V-8" O C (L8" DAYTON SUPERIOR 4y„ o oL EACH FACE, EACH WAY i TWO BOLT PRESET ANCHOR 5" "r OR EQUIVALENT MESH / r 16 2"CUR. i I �, — 1 t� (TYP.) VERTICAL BARS: a II — �G, - VERTICAL BARS: r BACKFACEONLY ? 2-#4@3"O.C. BACK FACE ONLY VERTICAL STEEL AT ANCHOR TO BE 2"CUR. FROM BACK #4 x 8'-0" FACE OF WALL (TYP.) III`l BACK FACE ONLY I SECTION ,6 I — — rL,V'O WEEPHOLE C=7 = THROUGH WINGWALL 1= 4 u LL �O CNTECH' ENGIMEHII), S0113i OM QC W s W.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 800-338-1122 513615-7000 513 645-7993 FAX REINFORCING DETAIL - WW1 B (FOR ANCHOR REINFORCING SEE SHEET S20) CM�SFIAJ W 0-SERIES.. FABRICATION DRAWING / PIiFLIP Cat: ANk"11 Lie. No. 45345 Q_ 4 PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA Digitally signed by Philip A. Creamer Date: 2022.03.10 14:12:20-05'00' QIECTNo.: 689028 1 010 3/10/2022 SIGNED: DRANM: JMF JCH ECKED: APPROVED: SPS PAC OF 3'-0" T-D" II II II I FH Fli Fd I HH — II II I 'E B TYPE B TYPE I_ 51-0" 1-- 5'-0" — WINGWALL - WW2A TOTAL WEIGHT = 9.2 TONS rL WALL ANCHOR rLLIFT POINTS (TOP 2 LIFT POINTS MUST BE CAPABLE OF SUPPORTING ENTIRE WEIGHT OF WINGWALL) #5 EACH FACE (TYP. ALL EDGES) VERTICAL BARS: 2-#4@3. O.C. BACK FACE ONLY I II VERTICAL STEEL AT ANCHOR TO BE 2" CLR. FROM BACK FACE OF WALL (TVP.) 94 @ 1'-6' O.C. EACH FACE, EACH WAY OR EQUIVALENT MESH VERTICAL BARS: 2-#4@3"O.C. BACK FACE ONLY 2" CLR. (TYP.) NOTES: -ALL EDGES OF PRECAST TO HAVE AY4" CHAMFER - ELEVATION IS LOOKING AT BACK FACE OF WINGWALL - BACK FACE DENOTES ANCHOR SIDE OF WINGWALL - WINGWALL WILL NOT HANG LEVEL. ADJUST CABLE LENGTHS AS REQUIRED WINGWALL CONCRETE REINF. STEEL W✓JF 28-DAY: 4000 PSI 60,000 PSI UNCOATED 65,000 PSI UNCOATED a .L/— WHEREVER THE REINFORCING IS CUT FOR THE I 1 #4 X 15'-2" PLACEMENT OF LIFT HOLES OR OTHER BLOCKOUTS, I I II II BACK FADE ONLY REINFORCING BARS OR WIRES OF EQUIVALENT CROSS -SECTIONAL AREA SHALL BE PLACED SYMMETRICALLY AROUND THE HOLE. AT LEAST ONE I;I,H II II FY I I J BAR MUST BE ON EACH SIDE OF THE HOLE, AND THE DEVELOPMENT LENGTH OF THE BAR MUST BE — i= \ _ _ _ ACHIEVED ON EITHER SIDE OF THE CUT. TYPE B TY E 13 5'-0" 2 O 3'-0" Z x< 0 2 O 4y„ 1L8" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR REINFORCING DETAIL - WW2A (FOR ANCHOR REINFORCING SEE SHEET S20) 10.4" SECTION 17 a•-10" 2'-g #5 EACH FACE #4 @ 1'$' O.C. 2'-6" (TYP. ALL EDGES) LIFT POINTS (TOP 2 LIFT EACH FACE, EACH WAY 8" 1•_p^ POINTS MUST BE CAPABLE OR EQUIVALENT MESH fj-8" DAYTON SUPERIOR OF SUPPORTING ENTIRE � — 2" CLR. TWO BOLT PRESET ANCHOR �`T aY WEIGHT OF WINGWALL) V2-#4 LBARS: BACK FACE ONLY VERTICAL BARS: 4j/2" 4i/" 2-#4@3"O.C. BACK FACE ONLY 17 " 18 VERTICAL STEEL AT ANCHOR I� I 31 —� N TO BE 2" CLR. FROM BACK C.G. FACE OF WALL71 0 0 w I SECTION 8 I I #4 x 9'-8" -- BACKFACEONLY ANCHOR WINGWALL - WW2B TOTAL WEIGHT = 8.0 TONS '""'" '—"IMARKI DATE I REVISION DESCRIPTION TYPETYPE B W O 5._p. 2$, _< REINFORCING DETAIL - WW26 (FOR ANCHOR REINFORCING SEE SHEET S20) 0`111111-414-1 EPWIMEHII), SOUMOM QC W s W.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 8DO-338-1122 513615-7000 513E45-7993 FAX MSPAL O-SERIES.. FABRICATION DRAWING Digitally signed b AT —AN Philip A. Creamer CRFAMEAT—AN > ic-P0.453 Date: 2022.03.10 Lic. No.45315 ,1, �. �� 14:12:36-05'00' PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA QIECT11- 689028 SEO. No.: DATE: 1 010 3/10/2022 SIGNED: DRANM: JMF JCH ECKED: APPROVED: SPS PAC OF 312" THICK EXPANSION BOARD PAD ATTACHED TO WINGWALL WITH CONSTRUCTION ADHESIVE (TYP.) yr ",Iu ma""e,.ymommawh,»n , remly d,,d,,maaw 1.b,l,ry w , anngl 1.x ed.... I.1d, dNm erei n ,.. a�do�a,rea 1. na&11um a 11i LV maell �mlary,In 23" TL,V'O WEEPHOLE THROUGH WINGWALL NOTES: -ALL EDGES OF PRECAST TO HAVE AY4" CHAMFER - ELEVATION IS LOOKING AT BACK FACE OF WINGWALL - BACK FACE DENOTES ANCHOR SIDE OF WINGWALL - WINGWALL WILL NOT HANG LEVEL. ADJUST CABLE LENGTHS AS REQUIRED 5" V-6" fL LIFT POINTS (TOP 2 LIFT #5 EACH FACE WINGWALL 1'$" POINTS MUST BE CAPABLE (TYP. ALL EDGES) CONCRETE REINF. STEEL VJ✓JF OF SUPPORTING ENTIRE 2" CUR. 28-DAY: 60,000 PSI 65,000 PSI TWEIGHT OF WINGWALL) 1 (TYP.) 4000 PSI UNCOATED UNCOATED I WHEREVER THE REINFORCING IS CUT FOR THE #4 @ 1,-ff„ O.C. I PLACEMENT OF LIFT HOLES OR OTHER BLOCKOUTS, 4y" EACH FACE, EACH WAY REINFORCING BARS OR WIRES OF EQUIVALENT OR EQUIVALENT MESH III CROSS -SECTIONAL AREA SHALL BE PLACED 4t/p VERTICAL BARS:SYMMETRICALLY AROUND THE HOLE. AT LEAST ONE _EsCH SIDE OF THE HOLE, 1 o 4-#6Q3"O.C. DPdENLO MENTONENGTH OF THE BAR MUST BEDTHE O BACK FACE ONLY ACHIEVED ON EITHER SIDE OF THE CUT. 20 VERTICAL STEEL AT ANCHOR 3 C.G TO BE 2" CLR. FROM BACK - FACE OF WALL (TYP.) III I om I I I I J III BACK FACE ONLY ILWALL ANCHOR WINGWALL - WW2C TOTAL WEIGHT = 5.3 TONS r. TYPEC 2 O ro # 2.-6., W U =a u LL � Q REINFORCING DETAIL - WW2C (FOR ANCHOR REINFORCING SEE SHEET S21) I-L8" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR SECTION 0 DATE I REVISION DESCRIPTION TLB" DAYTON SUPERIOR 4y2" TWO BOLT PRESET ANCHOR _ — - L:.. d"11111.414-1 ENGIPIEEMD SOUMOM QC W s W.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 800-338-1122 513615-7000 513 645-7993 FAX SECTION zo IIXIIN�SPAL O-SERIES.. FABRICATION DRAWN PEILIP ALAN CR-WmER Lie. No. 45345 PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA Digitally signed by Philip A. Creamer Date: 2022.03.10 14:12:50-05'00' QIECT No.: 689028 1 010 3/10/2022 SIGNED: DRAM: JMF JCH ECKED: APPROVED: SPS PAC OF 6'-6y' F4YY�—`J m n ^ o II I — II I FH #4 @ V-6" O.C. EACH FACE, EACH WAY #5 EACH FACE OR EQUIVALENT MESH (TYP. ALL EDGES) VERTICAL BARS: 2 -#4 @ 3" O.C. rLLIFT POINTS (TOP 2 LIFT —3-0 POINTS MUST BE CAPABLE VERTICAL BARS: BACK FACE ONLY 2 - #4 @ 3" O.C. n- VERTICAL BARS: 2'-0" OF SUPPORTING ENTIRE BACK FACE ONLY 2 - #5 @ 3" O.C. WEIGHT OF WINGWALL) BACK FACE ONLY \ 2"CLR. (TYP.) I I - VERTICAL STEEL AT ANCHOR #4 x 15•-2" - - TO BE 2"CLR. FROM BACK III 'III BACK FACE ONLY ,' a FACE OF WALL (TYP.) I— — — .— — — — fL WALL ANCHOR WINGWALL - WW3A TOTAL WEIGHT = 6.8 TONS �4-9Yr fLLIFT POINTS (TOP2 LIFT 9• POINTS MUST BE CAPABLE OF SUPPORTING ENTIRE WEIGHT OF WINGWALL) 4y" 4)2" 21 m o fO Q. 22 o m - I II I IILFH], 4 WALL ANCHOR WINGWALL - WW313 TOTAL WEIGHT = 7.2 TONS ' ""' "m"'P IMARKI DATE I REVISION DESCRIPTION #5 EACH FACE (TYP. ALL EDGES) VERTICAL BARS: 2-114@3"O.C. BACK FACE ONLY xQ � LL REINFORCING DETAIL - WW3A Q (FOR ANCHOR REINFORCING SEE SHEET S20) #4 @ 1'-0" O.C. EACH FACE, EACH WAY OR EQUIVALENT MESH 2" CLR. (TYP.) VERTICAL BARS: 2-#4@3"O.C. BACK FACE ONLY VERTICAL STEEL AT ANCHOR II 3I TO BE 2" CLR. FROM BACK FACE OF WALL (TYP.) #4 x 9'-8" BACK FACE ONLY �p I ` J TYPETYPE B W 00 5' 0" 2 E" =a u LL � 0 REINFORCING DETAIL - WW3B (FOR ANCHOR REINFORCING SEE SHEET S20) CNTECH' ENGIMEHII), SOUMOM QC W s W.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 800-338-1122 513615-7000 513 645-7993 FAX =N�SPAL O-SERIES.. FABRICATION DRAWING 4y" NOTES: -ALL EDGES OF PRECAST TO HAVE AY4" CHAMFER - ELEVATION IS LOOKING AT BACK FACE OF WINGWALL - BACK FACE DENOTES ANCHOR SIDE OF WINGWALL - WINGWALL WILL NOT HANG LEVEL. ADJUST CABLE LENGTHS AS REQUIRED WINGWALL CONCRETE REINF. STEEL W✓JF 28-DAY: 4000 PSI 60,000 PSI UNCOATED 65,000 PSI I UNCOATED WHEREVER THE REINFORCING IS CUT FOR THE PLACEMENT OF LIFT HOLES OR OTHER BLOCKOUTS, REINFORCING BARS OR WIRES OF EQUIVALENT CROSS -SECTIONAL AREA SHALL BE PLACED SYMMETRICALLY AROUND THE HOLE. AT LEAST ONE BAR MUST BE ON EACH SIDE OF THE HOLE, AND THE DEVELOPMENT LENGTH OF THE BAR MUST BE ACHIEVED ON EITHER SIDE OF THE CUT. IL8" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR SECTION 21 TL8" DAYTON SUPERIOR by TWO BOLT PRESET ANCHOR I p q p�/ IIIII -. SECTION 22 `n Digitally signed by PIiILIP� Philip A. Creamer ALAN caa.AacGx Date:2022.03.10 Lie. No. 45345 QIECTNo. SEMNo, DATE: 689029 010 3/10/2022 PLEASANT GREEN SUBDIVISION y JMF ~..'JCH CHECKED: APPROVED: SPS PAC ALBEMARLE COUNTY, VIRGINIA SHEET NO.: S16 DE SA' )'z" THICK EXPANSION BOARD PAD ATTACHED TO WINGWALL WITH CONSTRUCTION ADHESIVE (TYP.) 1'-0" 33/e� 2,E CLLIFT POINTS (TOP 2 LIFT POINTS MUST BE CAPABLE OF SUPPORTING ENTIRE WEIGHT OF WINGWALL) #5 EACH FACE (TYP. ALL EDGES) � II VERTICAL BARS: I 4-#6@3"O.C. BACK FACE ONLY 23 v. j C.G m m 24 VERTICAL STEEL AT ANCHOR j I o TO BE 2"CUR. FROM BACK o 1 o FACE OF WALL (TYP.) E" �f CL4"9 WEEPHOLE 1'E" fLWALL THROUGH WINGWALL ANCHOR WINGWALL - WW3C TOTAL WEIGHT = 9.8 TONS CL8" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR leie SECTION 23 '""' "m '_"IMARKI DATE I REVISION DESCRIPTION F. #4 @ V-6- O.C. EACH FACE, EACH WAY OR EQUIVALENT MESH 2" CLR. (TYP.) VERTICAL BARS: 2-#4@3"O.C. BACK FACE ONLY #4 x F-0" BACK FACE ONLY TYPE w O 5'-0' 2'$" =a I] �O REINFORCING DETAIL - WW3C (FOR ANCHOR REINFORCING SEE SHEET S20 & S21) CBS" DAYTON OR 4 , TWO BOLT PRESETT ANCHOR I / II II II o -p/ I1. I fI . ��JL, 0`111111.414-1 ENGIMEMD S0113i OM QC W s W.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45W9 800-338-1122 513615-7000 513 645-7993 FAX SECTION 24 /CGP�41113PA L O-SERIES.. FABRICATION DRAWING / PIIILIP ALAN CREAMER Lie. No.45345 PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA NOTES: -ALL EDGES OF PRECAST TO HAVE AY4" CHAMFER - ELEVATION IS LOOKING AT BACK FACE OF WINGWALL - BACK FACE DENOTES ANCHOR SIDE OF WINGWALL - WINGWALL WILL NOT HANG LEVEL. ADJUST CABLE LENGTHS AS REQUIRED WINGWALL CONCRETE REINF. STEEL W✓JF 28-DAY: 4000 PSI 60,000 PSI UNCOATED 65,000 PSI UNCOATED WHEREVER THE REINFORCING IS CUT FOR THE PLACEMENT OF LIFT HOLES OR OTHER BLOCKOUTS, REINFORCING BARS OR WIRES OF EQUIVALENT CROSS -SECTIONAL AREA SHALL BE PLACED SYMMETRICALLY AROUND THE HOLE. AT LEAST ONE BAR MUST BE ON EACH SIDE OF THE HOLE, AND THE DEVELOPMENT LENGTH OF THE BAR MUST BE ACHIEVED ON EITHER SIDE OF THE CUT. Digitally signed by Philip A. Creamer Date: 2022.03.10 14:13:55-05'00' QIECTNo.: 689028 1 010 3/10/2022 SIGNED: DRAM: JMF JCH ECKED: APPROVED: SPS PAC OF ILLIFT POINTS (TOP 2 LIFT POINTS MUST BE CAPABLE OF SUPPORTING ENTIRE WEIGHT OF WINGWALL) 4 LIFT POINTS (TOP 2 LIFT POINTS MUST BE CAPABLE OF SUPPORTING ENTIRE WEIGHT OF WINGWALL) yr remly ai.emm, aw 1.b,l,ry wp, anngl 1.x-d....I.1d—dN—erei n ,...—do�a,re.1. na&11u—a 11i LV mhlll F-- 3'-0� � WALL ANCHOR WINGWALL - WW4A TOTAL WEIGHT = 4.8 TONS 2'-6' #4 Q V-6- O.C. EACH FACE, EACH WAY OR EQUIVALENT MESH 4y VERTICAL BARS: F rQ3"O.C. BACKCKFACE ONLY 25 2" CLR. (TYP.) f i n q � #4 x 10'-2" I a BACK FACE ONLY 9" 4t/z' "� 25 HHGI ILWALL ANCHOR WINGWALL - WW41B TOTAL WEIGHT = 6.6 TONS DATE I REVISION DESCRIPTION LL� L �j _ iO TYPE B �B 2 w Z 3'-0" da �O #5 EACH FACE (TYP. ALL EDGES) VERTICAL BARS: 2-#4Q 3"O.C. BACK FACE ONLY VERTICAL STEEL AT ANCHOR TO BE 2" CLR. FROM BACK FACE OF WALL (TYP.) REINFORCING DETAIL - WW4A (FOR ANCHOR REINFORCING SEE SHEET S20) #5 EACH FACE #4 Q V-6" O.C. (TVP. ALL EDGES) EACH FACE, EACH WAY OR EQUIVALENT MESH �� I / (TVP.) i 'I I/ / VERTICAL BARS: VERTICAL BARS: r 2 - #4 Q 3" O.C. 2-#4Q 3"O.C. BACK FACE ONLY BACK FACE ONLY VERTICAL STEEL AT ANCHOR #4 x 8'-8" TO BE 2" CLR. FROM BACK BACK FACE ONLY I FACE OF WALL (TYP.) x_ TYPE B TYPE 8 da 2-0 50" 20 REINFORCING DETAIL - WW4B (FOR ANCHOR REINFORCING SEE SHEET S20) 0`11111-414-1 ENGIMEHII), SOUMONS QC W s W.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 8DO-338-1122 513615-7000 513 645-7993 FAX MSPAL O-SERIES.. FABRICATION DRAWN NOTES: -ALL EDGES OF PRECAST TO HAVE AY4" CHAMFER - ELEVATION IS LOOKING AT BACK FACE OF WINGWALL - BACK FACE DENOTES ANCHOR SIDE OF WINGWALL - WINGWALL WILL NOT HANG LEVEL. ADJUST CABLE LENGTHS AS REQUIRED WINGWALL CONCRETE REINF. STEEL VJ✓JF 28-DAY: 4000 PSI 60,000 PSI UNCOATED 65,000 PSI UNCOATED WHEREVER THE REINFORCING IS CUT FOR THE PLACEMENT OF LIFT HOLES OR OTHER BLOCKOUTS, REINFORCING BARS OR WIRES OF EQUIVALENT CROSS -SECTIONAL AREA SHALL BE PLACED SYMMETRICALLY AROUND THE HOLE. AT LEAST ONE BAR MUST BE ON EACH SIDE OF THE HOLE, AND THE DEVELOPMENT LENGTH OF THE BAR MUST BE ACHIEVED ON EITHER SIDE OF THE CUT. rL8" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR SECTION 25 4y„ IL8" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR 1 SECTION 26 1��gL'I'II / PIIILIP ALAN CREAMER Lic. No. 45345 gl. PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA Digitally signed by Philip A. Creamer Date: 2022.03.10 14:14:08-05'00' QIECT No.: 689028 SEO. No.: DATE: 1 010 3/10/2022 SIGNED: DRAM: JMF JCH ECKED: APPROVED: SPS PAC OF 4'-0,. 1'-0" TLLIFT POINTS(TOP2 LIFT rE" 2'-6"38 POINTS MUST BE CAPABLE 11-0" OF SUPPORTING ENTIRE WEIGHT OF WINGWALL) o} N F 4Yz" 4WALL'— ANCHOR WINGWALL - WW4C TOTAL WEIGHT = 8.2 TONS y" THICK EXPANSION BOARD PAD ATTACHED TO WINGWALL WITH CONSTRUCTION ADHESIVE (TYP.) TL,V'O WEEPHOLE THROUGH WINGWALL 4Y2, rL8" DAYTON SUPERIOR I TWO BOLT PRESET ANCHOR II ILA ' II p SECTION 27 DATE I REVISION DESCRIPTION #4 @ V-6.O.C. EACH FACE, EACH WAY OR EQUIVALENT MESH 2"CLR. (TYP.) � II � II �� II VERTICAL BARS: I 2-#4@37O.C. BACK FACE ONLY #5 EACH FACE (TYP. ALL EDGES) IIII IIII 4VERTICAL BARS: - ## I BACK FACE ONLY IIII IIII j VERTICAL STEEL AT ANCHOR IIII TO BE 2" CUR. FROM BACK III I FACE OF WALL (TYP.) #4 x 9'-0" IIII '1" f BACK FACE ONLY IIII_ _ III II I IflL� s is _ — —i-"I x_ TYPE B —MC IL < 2O REINFORCING DETAIL - WW4C (FOR ANCHOR REINFORCING SEE SHEET S20 & S21) I'LB" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR CNTECH' ENGIMEHIM SOUMOM QC W s W.ContechES.conn 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 800-338-1122 513615-7000 513 645-7993 FAX I �A II q ll l.IllL' SECTION 2B 1130P�48PAI W O-SERIES. FABRICATION DRAWING NOTES: -ALL EDGES OF PRECAST TO HAVE AY4" CHAMFER - ELEVATION IS LOOKING AT BACK FACE OF WINGWALL - BACK FACE DENOTES ANCHOR SIDE OF WINGWALL - WINGWALL WILL NOT HANG LEVEL. ADJUST CABLE LENGTHS AS REQUIRED WINGWALL CONCRETE REINF. STEEL W✓JF 28-DAY: 4000 PSI 60,000 PSI UNCOATED 65,000 PSI UNCOATED WHEREVER THE REINFORCING IS CUT FOR THE PLACEMENT OF LIFT HOLES OR OTHER BLOCKOUTS, REINFORCING BARS OR WIRES OF EQUIVALENT CROSS -SECTIONAL AREA SHALL BE PLACED SYMMETRICALLY AROUND THE HOLE. AT LEAST ONE BAR MUST BE ON EACH SIDE OF THE HOLE, AND THE DEVELOPMENT LENGTH OF THE BAR MUST BE ACHIEVED ON EITHER SIDE OF THE CUT. S X111 e at Digitally signed by Pell ALAIP '�tp, Philip A. Creamer ALAN y� .o Lie. N.45345 > Date:2022.03.10 NM�yJ 14:14:21-05'00' QIECTNo. SEQ.No. DATE: 689029 010 3/10/2022 PLEASANT GREEN SUBDIVISION y JMF ~..'JCH CHECKED: APPROVED: SPS PAC ALBEMARLE COUNTY, VIRGINIA SHEET NO.: S .I 19 DE SA, 62 BAR �2-B5BARS � B1, B6, B7, B8 B4 4 - 63 BARS, SPACED AS SHOWN FRONT FACE OF PLAN - TYPE A PRECAST WALL —/ WALL REINFORCING NOT SHOWN FOR CLARITY. SEE WINGWALL SHOP DRAWINGS FOR WALL REINFORCING. BAR LIST - TYPE A MARK CITY SIZE A TYPE LENGTH FINISH 131 3 96 3'-0" 3 EPDXY' B2 1 #5 STR. 1'-8" BLACK B3 4 95 STR. 2'-V' BLACK B4 6 95 STR. 2'-2" BLACK B5 2 95 2'-2" 2 BLACK B6 1 95 2'-Z' 1 BLACK B7 1 95 2'$" 1 BLACK BS 1 95 2' 9' 1 1 BLACK NOTE: "STR." DENOTES STRAIGHT BAR. STANDARD CLEARANCE =2" 62 BAR 2-65BARS 81, 86, 87 r 4 _ m N I 4 - B3 BARS, SPACED AS SHOWN FRONT FACE OF PLAN - TYPE B PRECAST WALL WALL REINFORCING NOT SHOWN FOR CLARITY. SEE WINGWALL SHOP DRAWINGS FOR WALL REINFORCING. 2" CUR. (MIN.) 3"CLR. (MIN.) — — '. •I - O N 1"EMBEDMENT ANCHOR REINFORCING NOT SHOWN FOR CLARITY SECTION - TYPE A V-0" a 6" 0 2'-6" LAP ?• a (TYP.) N B1 88 S+ (TYP.) 6 - B4 BARS, B7 SPACED AS SHOWN B2 B5 B3 o m B6 6" 30" 5 4" '-4" PRECAST ANCHOR TYPE A TOTAL WEIGHT = .428 TONS 5. A A� TYPE 1 0 �ATYPE 2 }--A-1 Z#8 HRC 150 OR #8 HRC 120 HEAD (OR EQUAL) WELDED TO #6 BAR TYPE 3 (EPDXY COATED-) 'NOTE: EPDXY COATING IS NOT REQUIRED ON HEADED ENDS OF TYPE 3 BARS, BUT WILL NOT BE DETRIMENTAL IF PROVIDED. 'NOTE: HRC HEADS PROVIDED BY HEADED REINFORCEMENT CORP. 1" EMBEDMENT \. ANCHOR REINFORCING 1'3" NOT SHOWN FOR CLARITY SECTION - TYPE B J 6" = 2'-6" LAP B7 G (TYP.) LzoW 81A B2 BiB Knm 7 - B4 BARS, SPACED AS SHOWN B3 B5 B6 PRECAST ANCHOR TYPE B TOTAL WEIGHT = .765 TONS BAR LIST - TYPE B MARK CITY SIZE A TYPE LENGTH FINISH B1A 1 96 T-9' 3 EPDXY' B1B 1 96 Z-6' 3 EPDXY' B2 1 #5 STR. 3'-2" BLACK B3 4 95 STR. 4'-3" BLACK B4 7 95 STR. 2'-2" BLACK B5 2 95 T-8" 2 BLACK B6 1 95 2'-2" 1 BLACK B7 1 95 T-T' 1 BLACK NOTE: "STR." DENOTES STRAIGHT BAR. STANDARD CLEARANCE =2" Digitally signed by 0 P LAN y Philip A. Creamer y AAN .N.5� Lic. o45345 �Date:2022.03.10 _CA 14:14:33-05'00' n rvpn�"n°mo,mav°n ancm mmv—r vpmva° v ,.•�'°�`�:`.. PRQIECT11- SEMN- DATE: m�..d,-W .. e.��f,p—r :p,°a�", C� NTECH' /���.\ �.�#�Y 6MED: oio 3/1o/zozz '.. t,mm ly,,d m. p,m,wn •,nvemm MM1yd,m.m,"°.1,e, n,-p°°"Dr„� ,m. . DMINEEBED SOLUTIONS uc / \SP�. -SERIES PLEASANT GREEN SUBDIVISION DESIGNED: JMF DRAWN: JCH � w CHECKED: APPROVED: ° ""°°g'o ix°' °°'u'1-pp°�;"u; .ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45059 FABRICATION SPS PAC m"m"' "`""°'°°""'"°"°"°" SHEET NO.: ,a-,e-d m m1..°p. �„m, 1w 800-338-1122 5136157000 513E4S7993 FAX Da WNc ALBEMARLE COUNTY, VIRGINIA p p MARK DATE REVISION DESCRIPTION BV S20 oP S26 B2 BAR (TYP.) �2-B5 BARS � B1, B6, B7, B8, B9 B4 4-B3 BARS, SPACED AS SHOWN FRONT FACE OF PLAN -TYPE C PRECAST WALL WALL REINFORCING NOT SHOWN FOR CLARITY. SEE WINGWALL SHOP DRAWINGS FOR WALL REINFORCING. 2" CLR (MIN.) BAR LIST - TYPE C MARK CITY SIZE A TYPE LENGTH FINISH B1 4 #6 3'-0" 3 EPDXY' 62 2 #5 STR. 3'-2" BLACK 63 4 #5 STR. 4'-3" BLACK 64 7 #5 STR. 2'-2" BLACK 65 2 #5 314" 2 BLACK 86 1 #5 3'-2" 1 BLACK 67 1 #5 4'-2" 1 BLACK B8 1 #5 4'-5" 1 BLACK B9 1 1 #5 1 4'-W' 1 1 BLACK NOTE: "STR" DENOTES STRAIGHT BAR. STANDARD CLEARANCE =2" V EMBEDMENT ANCHOR REINFORCING 2-3" NOT SHOWN FOR CLARITY SECTION - TYPE C A� TYPE 1 0 ul Q 1'-0" TYPE 2 O n 6" _ 2'$" LAP ro rn B1 (TYP.) B8 �+' w (TYP) B8 S+ #8 HRC 15C OR 7 - 64 BARS, #8 HRC 120 HEAD (OR EQUAL) 'P B7 SPACED AS SHOWN WELDED TO #6 BAR gL`ITI rt, B2`°�� `'. Digitally signed by BS TYPE 3 r 4l 83 (EPDXY COATED-) piiILIP o" ALA,4 Philip A. Creamer io m *NOTE: EPDXY COATING IS NOT REQUIRED CgEAUR OIL HEADED ENDS OF TYPE 3 BARS, BUT Date: 2 022 .03.10 s" 5%a" L. . 45345 2'-4" WILL NOT BE DETRIMENTAL IF PROVIDED. icNo � � 'NOTE: HRC HEADS PROVIDED BY 14 -14 -49-05100' PRECAST ANCHOR HEADED REINFORCEMENT CORP. OSInTjAj TYPE C TOTAL WEIGHT = .896 TONS a. rvpn�"ne im°,mamn •ncm mmv a,rvnnp bp,"vbe PRQIECTNo.: SEEM No.: DATE: "°"°�`•a `ire°� a 689029 010 3/10/2022 °aro: w e.,°v.e :p,°e� °, / CNTECH' Yiil� ,m,,, p..°°v.mm O-SERIES.. DesiDr+ED: DRavm: e•w.m•.°.�,e,no,�p°°•Dr„�° eNG�N�E�BSOIUiIWiSuc PLEASANT GREEN SUBDIVISION JMF JCH •l v www.ContechES.com CHECKED: aPPRovED: ""°"'"'�,'p°'u'1°�;"u; m"M"' ° 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45059 SPS PAC FABRICATION SHEET No.: "°°""'"e"°"°" ALBEMARLE COUNTY, VIRGINIA e...e�m�...p,�800-338-1122 5136iS7000 513E4S7993 FAX oanwiNc p MARK DATE REVISION DESCRIPTION BY S21 DE S26 rLTHREADEDINSERT 45° BEND FOR 1"0 BOLT (TYP. 2 STRUT06"± rL6" DAYTON SUPERIOR TWO BOLT rL6" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR FOR 1"0 x 6" PRESET ANCHOR FOR 1"0 x 6" THREADED ROD (2) WITH DOUBLE NUTS PRECAST THREADED ROD (2) WITH DOUBLE NUTS PRECAST [ALT. 1"0 x 2s/4" BOLTS, (6" PITCH)] HEADWALL [ALT. 1"0 x 2s/4" BOLTS, (6" PITCH)] HEADWALL /2" RAD. (TYP.) -1) Z (PW-1) M = 8" t 3"t OR 4"t SIDE VIEW FRONT VIEW L rL8" DAYTON SUPERIOR TWO BOLT �5 (LIT' DAYTON SUPERIOR TWO BOLT �� N DAYTON SUPERIOR PRESET ANCHOR FOR I"0 x 6" THREADED ROD (2) WITH DOUBLE NUTS (-1) G~. PRESET ANCHOR FOR I"0 x 6' THREADED ROD (2) WITH DOUBLE NUTS /z. .,/' (PW-1) TWO BOLT PRESET ANCHOR [ALT. 1"0 x 2" BOLTS, (6" PITCH)] �'�^'., P-1 [ALT. 1 "0 x 2'/1' BOLTS, (6" PITCH)] .,K P-2 2o- PRECAST WINGWALL PLAN VIEW TYPICAL CONNECTION DETAIL - P-1 PRECAST WINGWALL ni ANi 1n17tAt TYPICAL CONNECTION DETAIL - P-2 1Jb"O HOLE 1p PW-1 (ftWASHER, y" x 4" x 4") pti (GALVANIZED AS PER ASTM A123) ZY" 4 q., 4t/z" 2Y2" 2%" 4 q., 4%2' 2t/2" rL(2) 2"0 HOLES rL(2) 2" x 3" SLOTS L rL(2) 2"0 HOLES rL(2) 2" x 3" SLOTS N N I I I i0 O I I I I I I ip b I I I I I I I N N HEADWALL LEG WINGWALL LEG HEADWALL LEG WINGWALL LEG PP=1 PP=2 (it, 1"x 14" x 10") (R,1"x 14" x 10") tgLTrp' (GALVANIZED AS PER ASTM A123) (GALVANIZED AS PER ASTM A123) /�f4�tLl ` Digitally signed by PLATE P-1 PLATE P-2 PHILIP AI Philip A. Creamer AN y TOTAL REQUIRED= 4 TOTAL REQUIRED= 4 (4) PW-1 REQ'D PER PLATE (4) PW-1 REQ'D PER PLATE Lie. No. 45345 casA.aci;x Date: 2 0 2 2.0 3.10 _ 101 14:15:03-05'00' n rvpn�"no m°rmav°n ancm mmv arrvnnp vprova° PRQIECTNo.: SEMNo.: DATE: d...,. � th. , °v.a :pr°a °r C NTECH' /C0�sp� 689029 010 3/10/2022 DesiONED: DRavm: °,mm.°°.r.pn°m m. p,m„min.,,.°°..mm C PLEASANT GREEN SUBDIVISION ��.a•w.m,.°.,e,no,mp°°"Dr„ "l .. eNGINEERMSOWTIOMILC `y}L 7IG� JMF JCH w CHECKED: APPROVED: ""°° ° .ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45W9 FABRICATION SPS PAC g'o°'"m"' """"'°-.—,"°"°" 800-338-1122 5136157000 513E4S7993 FAX SHEET NO.: p p c22 c26 "®Pa°°rm�r„�°, anpm e...am m�..°p, �„mmw.�.m oanwiNc ALBEMARLE COUNTY, VIRGINIA °„remm,m m,:°p �m ew mn.r.. MARK DATE REVISION DESCRIPTION BV OF wry - '.IN—,,'yJ' m u arol:,w �...a :...... _.•hh.m by in yynn........ .r ybh ressly m.eam...vh ehiry o,,a.... eirip ro anngl ch 1.x d.... I hl4—d it ..ire—ii. ce byb. ter. u-,-b.yd-a.u..sre.m.,N—I RMARKDATE REVISION DESCRIPTION PRECAST WINGWALL FLS" DAVTON SUPERIOR TWO BOLT PRESET ANCHOR FOR 1"0 x 6" THREADED ROD (2) WITH DOUBLE NUTS [ALT. 1 "0 x 23/4" BOLTS, (6" PITCH)] «Z �z o PRECAST WINGWALL P-3 VVI 45° BEND (TYP. 2 STRUTS) SIDE VIEW FRONT VIEW DAYTON SUPERIOR TWO BOLT PRESET ANCHOR >y, . . A N i PI ANI \/IF1A/ TYPICAL CONNECTION DETAIL - P-3 I I 44" 4y4" 4y" 2y" I I (L(2) 2"0 HOLES P-3 (it, 1" x 14" x 10") (GALVANIZED AS PER ASTM A123) PLATE P-3 TOTAL REQUIRED= 14 (4) Pi REQ'D PER PLATE C NTECHO EPMsIIIIII Souinom uC W W W.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 800-338-1122 513-645-7000 513-645-7993 FAX -i— FABRICATION DRAW NG 3" SLOTS yAVT;i�/ 7 PIiILIP AL.AN ^r:> CREANWR Lic. No. 45345 4.4 PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA 1Jb"O HOLE PW-1 (FEWASHER, y" x 4" x 4") (GALVANIZED AS PER ASTM A123) Digitally signed by Philip A. Creamer Date: 2022.03.10 14:15:19-05'00' Obi SEG. No: DNTE: 689029 010 3/10/2022 SIGNED: DMWN: JMF JCH ECKED: 7vvaovE7 SPS PAC OF rLTHREADEDINSERT 45° BEND FOR VO BO447± (TYP. 2 STRUTS) — m BUTYL ROPE, PRIMER & tY2'• RAD. (TYP.) JOINT WRAP INSTALLED UNDER TIE PLATE 2<'" Z' 6" T-0" 6" 2" 8" 4- it/e"0 HOLES y" SIDE VIEW FRONT VIEW 0 k�* - J DAYTON SUPERIOR f } TWO BOLT PRESET ANCHOR DAYTON SUPERIOR TWO GALVANIZED It(P-4) BOLT PRESET ANCHOR DETAIL 29 Z _ END UNIT v m a ly"'O HOLE IIIr _— --_ 2�1 2 INTERIOR UNIT 4 JOINT WRAP & PRIMER INSTALLED PW-1 UNDER TIE PLATE I~8"� Y22"x4"x 4"GALV (QWASHER, Y'x 4"x4") ILWASHER (PW-1)(T/P.) (GALVANIZED AS PER ASTM A123) 3 - BUNDLES OF ADDITIONALREINFORCING- 2-#6x6'-0" 3„ REINFORCING BLOCKOUT-CUT BRIDGE END UNIT t •.'f SEE REINFORCING BLOCKOUT TOP FACE ONLY OUT TOP LAVER IE REINFORCING IIIII, I ,IIIIIII. (A3 OR A4)MESH(ES)AND ADD ''IIUII Illlll - "'I 1 DETAIL ON THIS SHEET BARS SHOWN REINFORCING NOT .I��L_ ���) I':' SHOWN FOR CLARITY BRIDGE INTERIOR UNIT REINFORCING BLOCKOUT DETAIL rL8" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR FOR VO x 2%" BOLTS, (6" PITCH) W/ ROUND WASHERS BUTYL ROPE rL1"O x 9" LONG HILTI KWIK BOLT 3 EXPANSION ANCHOR OR APPROVED EQUAL. INSTALL IN FIELD DRILLED HOLES W/ MINIMUM 6" EMBEDMENT, AS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS (TYP.) SECTION 30 PLATE P-4 TOTAL REQUIRED= 8 (4) PW-1 REQ'D PER PLATE Digitally signed f P Ip by Philip A. `AM CREARiFiR Creamer Lie. No. 453as Date: 2022.03.10 .....,� 14:15:34-05'00' 40NAL n rvpn—ano mormav°n ancm mmv arrvnnp vprova° PRQIECTNo.: SEMN- DATE: " ' `°A °�'�' `: �°v.a /=N�SP� 689029 010 3/10/2022 d...,. -thy :p.°a °. C NTECH' DesiONED: DRavm: m. p•m•,m.n.°.°°..mm 'ml.a•w.m,.°.1,e,no,m,p°°"Dr„� C PLEASANT GREEN SUBDIVISION .l .. eNGINEERMSOUTIOMILC `y}L 7IG� JMF JCH "°.mm,.pn°m www.ContechES.com CHECKED: APPROVED: ° ""°°g'o°'u'1°�;"u; 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45059 FABRICATION SPS PAC m"m"' °"°"°" 800-335-1122 5136iS7000 513E4S7993 FAX SHEET NO.: o p .®Pa°°rm�r„m•anp°. e...am , �,�mmw.�.m oanwiNc ALBEMARLE COUNTY, VIRGINIA MARK DATE REVISION DESCRIPTION BV S24 °F J"LG SPECIFICATIONS FOR MANUFACTURE AND INSTALLATION OF CON/SPAN® O-SERIES BRIDGE SYSTEMS 1. DESCRIPTION 1.1. TYPE- THIS WORK SHALL CONSIST OF FURNISHING AND CONSTRUCTING A CONISPAN® CSERIES BRIDGE SYSTEM IN ACCORDANCE WITH THESE SPECIFICATIONS AND IN REASONABLY CLOSE CONFORMITY WITH THE LINES, GRADES, DESIGN AND DIMENSIONS SHOWN ON THE PUNS OR AS ESTABLISHED BY THE ENGINEER. IN SITUATIONS "ERE TWO OR MORE SPECIFICATIONS APPLY TO THIS WORK, THE MOST STRINGENT REQUIREMENTS SHALL GOVERN. 1.2. DESIGNATION- PRECAST REINFORCED CONCRETE CONIMM*M OSERIES BRIDGE UNITS MANUFACTURED IN ACCORDANCE WITH THIS SPECIFICATION SHALL BE DESIGNATED BY SPAN AND RISE. PRECAST REINFORCED CONCRETE WINGWALLS AND HEADWALLS MANUFACTURED IN ACCORDANCE WITH THIS SPECIFICATION SHALL BE DESIGNATED BY LENGTH, HEIGHT, AND DEFLECTION ANGLE. PRECAST REINFORCED CONCRETE EXPRESS- FOUNDATION UNITS MANUFACTURED IN ACCORDANCE WITH THIS SPECIFICATION SHALL BE DESIGNATED BY LENGTH, HEIGHT AND WIDTH. 2. DESIGN 21. SPECIFICATIONS- THE PRECAST ELEMENTS ARE DESIGNED IN ACCORDANCE WITH THE 'AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS' 8TH EDITION, ADOPTED BY THE AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS, 201T A MINIMUM OF ONE FOOT OF COVER ABOVE THE CROWN OF THE BRIDGE UNITS IS REQUIRED IN THE INSTALLED CONDITION. (UNLESS NOTED OTHERWISE ON THE SHOP DRAWINGS AND DESIGNED ACCORDINGLY) 3. MATERIALS 3.1. CONCRETE -THE CONCRETE FOR THE PRECAST ELEMENTS SHALL BE AIR -ENTRAINED WHEN INSTALLED IN AREAS SUBJECT TO FREEZE -THAW CONDITIONS, COMPOSED OF PORTLAND CEMENT, FINE AND COARSE AGGREGATES, ADMIXTURES AND WATER. AIR -ENTRAINED CONCRETE SHALL CONTAIN 642 PERCENT AIR. THE AIR- ENTRAINING ADMIXTURE SHALL CONFORM TO AASHT0 M1St. SHOWN ON THE SHOP DRAWINGS. 3.1.1.1PORTLAND CEMENT- SHALL CONFORM TO THE REQUIREMENTS OF ASTM SPECIFICATIONS C150-TYPE I, TYPE II, OR TYPE III CEMENT. 3.1.2.COARSE AGGREGATE -SHALL CONSIST OF STONE HAVING A MAXIMUM SIZE OF 1 INCH. AGGREGATE SHALL MEET REQUIREMENTS FOR ASTM C33. 3.1.3. WATER REDUCING ADMIXTURE -THE MANUFACTURER MAY SUBMIT, FOR APPROVAL BY THE ENGINEER, A WATER -REDUCING ADMIXTURE FOR THE PURPOSE OF INCREASING WORKABILITY AND REDUCING THE WATER REQUIREMENT FOR THE CONCRETE. 3.1.4.CALCIUM CHLORIDE -THE ADDITION TO THE MIX OF CALCIUM CHLORIDE OR ADMIXTURES CONTAINING CALCIUM CHLORIDE WILL NOT BE PERMITTED. 3.1.5.MIXTURE - THE AGGREGATES, CEMENT AND WATER SHALL BE PROPORTIONED AND MIXED IN A BATCH MWER TO PRODUCE A HOMOGENEOUS CONCRETE MEETING THE STRENGTH REQUIREMENTS OF THIS SPECIFICATION. THE PROPORTION OF PORTLAND CEMENT IN THE MIXTURE SHALL NOT BE LESS THAN 566 POUNDS I6 SACKS) PER CUBIC YARD OF CONCRETE. 3.2. STEEL REINFORCEMENT 3.2.1.THE MINIMUM STEEL YIELD STRENGTH SHALL BE 60,000 PSI, UNLESS OTHERWISE NOTED ON THE SHOP DRAWINGS. 12.Z ALL REINFORCING STEEL FOR THE PRECAST ELEMENTS SHALL BE FABRICATED AND PLACED IN ACCORDANCE WITH THE DETAILED SHOP DRAWINGS SUBMITTED BY THE MANUFACTURER. 3.2.3.REINFORCEMENT SHALL CONSIST OF WELDED WIRE REINFORCING CONFORMING TO ASTM SPECIFICATION A 1064, OR DEFORMED STEEL BARS CONFORMING TO ASTM SPECIFICATION A 615, GRADE 60. LONGITUDINAL DISTRIBUTION REINFORCEMENT MAY CONSIST OF WELDED WIRE FABRIC OR DEFORMED BILLET -STEEL BARS. 3.3. STEEL HARDWARE 3.3.1.BOLTS AND THREADED ROBS FOR WINGWALL CONNECTIONS SHALL CONFORM TO ASTM A 30T NUTS SHALL CONFORM TO AASHTO M292 (A5TM A194) GRADE 2H. ALL BOLTS, THREADED RODS AND NUTS USED IN WINGWALL CONNECTIONS SHALL BE MECHANICALLY ZINC COATED IN ACCORDANCE WITH ASTM B695 CLASS50. 3.3.2. STRUCTURAL STEEL FOR WINGWALL CONNECTION PLATES AND PLATE WASHERS SHALL CONFORM TO AASHTO M 270 (ASTM A 709) GRADE 36 AND SHALL BE HOT DIP GALVANIZED AS PER AASHTO M111 (ASTM A123). 3.3.3.INSERTS FOR WINGWALLS SHALL BE 1" DIAMETER TWO -BOLT PRESET WINGWALL ANCHORS AS MANUFACTURED DAYTON SUPERIOR CONCRETE ACCESSORIES, MIAMISBURG, OHIO, (800) 7453700 AND SHALL BE ELECTRO GALVANIZED IN ACCORDANCE WITH ASTM 13633 SC-1. 3.3.4.FERRULE LOOP INSERTS SHALL BE FS4 FERRULE LOOP INSERTS AS MANUFACTURED BY DAYTON SUPERIOR CONCRETE ACCESSORIES, MIAMISBURG, OHIO, (800) 7453700 AND SHALL BE ELECTRO GALVANIZED. 3.3.5.INSERTS FOR DETACHED HEADWALL CONNECTIONS SHALL BE AISI TYPE 304 STAINLESS STEEL, EXPANDED COIL INSERTS AS MANUFACTURED BY DAYTON SUPERIOR CONCRETE ACCESSORIES, MIAMISBURG, OHIO, (800) 7453700. COIL RODS AND NUTS USED IN HEADWALL CONNECTIONS SHALL BE AISI TYPE 304 STAINLESS STEEL. WASHERS USED IN HEADWALL CONNECTIONS SHALL BE EITHER AISI TYPE 304 STAINLESS STEEL PLATE WASHERS OR AASHTO W70 (ASTM A709) GRADE 36 PLATE WASHERS HOT DIP GALVANIZED AS PER AASHTO M111 (ASTM A123L 3.3S.MECHANICAL SPLICES OF REINFORCING BARS SHALL BE MADE USING THE DOWEL BAR SPLICER SYSTEM AS MANUFACTURED BY DAYTON SUPERIOR CONCRETE ACCESSORIES, MIAMISBURG, OHIO, (800) 745-3700, AND SHALL CONSIST OF THE DBDI SPLICE SYSTEM (DOWEL BAR SPLICER AND DOWEL -IN), OR AS MANUFACTURED BY MRSPLICE PRODUCTS INC, DAYTON, OHIO, (937)-27"700, AND SHALL CONSIST OF BARSPLICER XP TYPE 2 SYSTEM. 4. MANUFACTURE OF PRECAST ELEMENTS- SUBJECT TO THE PROVISIONS OF SECTION 5, BELOW, THE PRECAST ELEMENT DIMENSION AND REINFORCEMENT DETAILS SHALL BE AS PRESCRIBED IN THE PLAN AND SHOP DRAWINGS PROVIDED BY THE MANUFACTURER. 4A. FORMS -THE FORMS USED IN MANUFACTURE SHALL BE SUFFICIENTLY RIGID AND ACCURATE TO MAINTAIN THE REQUIRED PRECAST ELEMENT DIMENSIONS WITHIN THE PERMISSIBLE VARIATIONS GIVEN IN SECTION 5OF THESE SPECIFICATIONS. ALL CASTING SURFACES SHALL BE OF A SMOOTH MATERIAL. 4.2. PLACEMENT OF REINFORCEMENT 4.2.1. PLACEMENT OF REINFORCEMENT IN PRECAST BRIDGE UNITS - THE COVER OF CONCRETE OVER THE OUTSIDE CIRCUMFERENTIAL REINFORCEMENT SHALL BE 2" MINIMUM. THE COVER OF CONCRETE OVER THE INSIDE CIRCUMFERENTIAL REINFORCEMENT SHALL BE I& MINIMUM, UNLESS OTHERWISE NOTED ON THE SHOP DRAWINGS. THE CLEAR DISTANCE OF THE END CIRCUMFERENTIAL WIRES SHALL NOT BE LESS THAN 1' NOR MORE THAN 2' FROM THE ENDS OF EACH SECTION. REINFORCEMENT SHALL BE ASSEMBLED UTILIZING SINGLE OR MULTIPLE LAYERS OF WELDED WIRE FABRIC (NOT TO EXCEED 3 LAVERS), SUPPLEMENTED WITH A SINGLE LAYER OF DEFORMED BILLET -STEEL BARS, WHEN NECESSARY. WELDED WIRE FABRIC SHALL BE COMPOSED OF CIRCUMFERENTIAL AND LONGITUDINAL WIRES MEETING THE SPACING REQUIREMENTS OF 4.3, BELOW, AND SHALL CONTAIN SUFFICIENT LONGITUDINAL WIRES EXTENDING THROUGH THE BRIDGE UNIT TO MAINTAIN THE SHAPE AND POSITION OF THE REINFORCEMENT. LONGITUDINAL DISTRIBUTION REINFORCEMENT MAY BE WELDED WIRE FABRIC OR DEFORMED BILLETSTEEL BARS AND SHALL MEET THE SPACING REQUIREMENTS OF 4.3. BELOW. THE ENDS OF THE LONGITUDINAL DISTRIBUTION REINFORCEMENT SHALL BE NOT MORE THAN 3" AND NOT LESS THAN 1)," FROM THE ENDS OF THE BRIDGE UNIT. 4.2.2. BENDING OF REINFORCEMENT FOR PRECAST BRIDGE UNITS - THE OUTSIDE AND INSIDE CIRCUMFERENTIAL REINFORCING STEEL FOR THE CORNERS OF THE BRIDGE SHALL BE BENT TO SUCH AN ANGLE THAT IS APPROXIMATELY EQUAL TO THE CONFIGURATION OF THE BRIDGES OUTSIDE CORNER. 4.2.3. PLACEMENT OF REINFORCEMENT FOR PRECAST WINGWALLS AND HEADWALLS -THE COVER OF CONCRETE OVER THE LONGITUDINAL AND TRANSVERSE REINFORCEMENT SHALL BE 2" MINIMUM. THE CLEAR DISTANCE FROM THE END OF EACH PRECAST ELEMENT TO THE END OF REINFORCING STEEL SHALL NOT BE LESS THAN 1 W NOR MORE THAN 3'. REINFORCEMENT SHALL BE ASSEMBLED UTILIZING A SINGLE LAYER OF WELDED WIRE FABRIC, OR A SINGLE LAYER OF DEFORMED BILLET -STEEL BARS. WELDED WIRE FABRIC SHALL BE COMPOSED OF TRANSVERSE AND LONGITUDINAL WIRES MEETING THE SPACING REQUIREMENTS OF 4.3, BELOW, AND SHALL CONTAIN SUFFICIENT LONGITUDINAL WIRES EXTENDING THROUGH THE ELEMENT TO MAINTAIN THE SHAPE AND POSITION OF THE REINFORCEMENT. LONGITUDINAL REINFORCEMENT MAY BE WELDED WIRE FABRIC OR DEFORMED BILLET -STEEL BARS AND SHALL MEET THE SPACING REQUIREMENTS OF 4.3, BELOW. 4.2.4. PLACEMENT OF REINFORCMENT FOR PRECAST FOUNDATION UNITS -THE COVER OF CONCRETE OVER THE BOTTOM REINFORCEMENT SHALL BE 3INCHES MINIMUM. THE COVER OF CONCRETE FOR ALL OTHER REINFORCEMENT SHALL BE 2 INCHES MINIMUM. THE CLEAR DISTANCE FROM THE END OF EACH PRECAST ELEMENT TO THE END OF REINFORCING STEEL SHALL NOT BE LESS THAN 2INCHES NOR MORE THAN 3INCHES. REINFORCEMENT SHALL BE ASSEMBLED UTILIZING A SINGLE LAYER OF WELDED WIRE FABRIC OR A SINGLE LAYER OF DEFOREMED BILLET -STEEL BARS. WELDED WIRE FABRIC SHALL BE COMPOSED OF TRANSVERSE AND LONGITUDINAL WIRES MEETING THE SPACING REQUIREMENTS OF 4.3, BELOW, AND SHALL CONTAIN SUFFICIENT LONGITUDINAL WIRES EXTENDING THROUGH THE ELEMENT TO MAINTAIN THE SHAPE AND POSITION OF THE REINFORCEMENT. LONGITUDINAL REINFORCEMENT MAY BE WELDED WIRE FABRIC OR DEFORMED BILLET -STEEL BARS AND SHALL MEET THE SPACING REQUIREMENTS OF 4.3, BELOW. 4.3. LAPS WELDS, SPACING 4.3.1. LAPS WELDS, AND SPACING FOR PRECAST BRIDGE UNITS - TENSION SPLICES IN THE CIRCUMFERENTIAL REINFORCEMENT SHALL BE MADE BY LAPPING. LAPS MAY BE TACK WELDED TOGETHER FOR ASSEMBLY PURPOSES. FOR SMOOTH WELDED WIRE FABRIC, THE OVERLAP SHALL MEET THE REQUIREMENTS OF AASHTO 5.10.81.513 AND 5.10.8.5.2. FOR DEFORMED WELDED WIRE FABRIC, THE OVERLAP SHALL MEET THE REQUIREMENTS OF AASHTO S.10.83.5A AND SA0.8.5.1. THE OVERLAP OF WELDED WIRE FABRIC SHALL BE MEASURED BETWEEN THE OUTER -MOST LONGITUDINAL WIRES OF EACH FABRIC SHEET. FOR DEFORMED BILLET -STEEL BARS, THE OVERLAP SHALL MEET THE REQUIREMENTS OF AASHTO 5.10.81.1 FOR SPLICES OTHER THAN TENSION SPLICES, THE OVERLAP SHALL BE A MINIMUM OF 1'-0" FOR WELDED WIRE FABRIC OR DEFORMED BILLETSTEEL BARS. THE SPACING CENTER TO CENTER OF THE CIRCUMFERENTIAL WIRES IN A WIRE FABRIC SHEET SHALL BE NOT LESS THAN T NOR MORE THAN 4". THE SPACING CENTER TO CENTER OF THE LONGITUDINAL WIRES SHALL NOT BE MORE THAN W. THE SPACING CENTER TO CENTER OF THE LONGITUDINAL DISTRIBUTION STEEL FOR EITHER LINE OF REINFORCING IN THE TOP SLAB SHALL BE NOT MORE THAN 1'4'. 4.3.2. LAPS WELDS, AND SPACING FOR PRECAST WINGWALLS, HEADWALLS AND FOUNDATIONS -SPLICES IN THE REINFORCEMENT SHALL BE MADE BY LAPPING. LAPS MAY BE TACK WELDED TOGETHER FOR ASSEMBLY PURPOSES. FOR SMOOTH WELDED WIRE FABRIC, THE OVERLAP SHALL MEET THE REQUIREMENTS OF AASHTO S.10.81.513 AND SAB8.5.2. FOR DEFORMED WELDED WIRE FABRIC, THE OVERLAP SHALL MEET THE REQUIREMENTS OF AASHTO 5.10.8.2.5A AND SAB8.5.1. FOR DEFORMED BILLET -STEEL BARS, THE OVERLAP SHALL MEET THE REQUIREMENTS OF AASHTO 5.10.8.2.1. THE SPACING DATE I REVISION DESCRIPTION CENTER -TO -CENTER OF THE WIRES IN A WIRE FABRIC SHEET SHALL BE NOT LESS THAN 2' NOR MORE THAN W. 44. CURING- THE PRECAST CONCRETE ELEMENTS SHALL BE CURED FOR A SUFFICIENT LENGTH OF TIME SO THAT THE CONCRETE WILL DEVELOP THE SPECIFIED COMPRESSIVE STRENGTH IN 28 DAYS OR LESS. ANY ONE OF THE FOLLOWING METHODS OF CURING OR COMBINATIONS THERE OF SHALL BE USED: 4A.1.STEAM CURING -THE PRECAST ELEMENTS MAY BE LOW-PRESSURE STEAM CURED BY A SYSTEM THAT WILL MAINTAIN A MOIST ATMOSPHERE. 4A.2. WATER CURING -THE PRECAST ELEMENTS MAY BE WATER CURED BY MY METHOD THAT WILL KEEP THE SECTIONS MOIST. 4A.3. MEMBRANE CURING -A SEALING MEMBRANE CONFORMING TO THE REQUIREMENTS OF ASTM SPECIFICATION C309 MAY BE APPLIED AND SHALL BE LEFT INTACT UNTIL THE REQUIRED CONCRETE COMPRESSIVE STRENGTH IS ATTAINED. THE CONCRETE TEMPERATURE AT THE TIME OF APPLICATION SHALL BE WITHIN +/-10 DEGREES F OF THE ATMOSPHERIC TEMPERATURE. ALL SURFACES SHALL BE KEPT MOIST PRIOR TO THE APPLICATION OF THE COMPOUNDS AND SHALL BE DAMP WHEN THE COMPOUND IS APPLIED. 4.5. STORAGE, HANDLING & DELIVERY 4.5.1. STORAGE - PRECAST CONCRETE BRIDGE ELEMENTS SHALL BE LIFTED AND STORED IN "ASL POSITION. PRECAST CONCRETE HEADWALL AND WINGWALL UNITS ARE CAST, STORED AND SHIPPED IN A FLAT POSITION. THE PRECAST ELEMENTS SHALL BE STORED IN SUCH A MANNER TO PREVENT CRACKING OR DAMAGE. STORE ELEMENTS USING TIMBER SUPPORTS AS APPROPRIATE. THE UNITS SHALL NOT BE MOVED UNTIL THE CONCRETE COMPRESSIVE STRENGTH HAS REACHED A MINIMUM OF 2500 PSI (3000 PSI FOR SPANS � FEET), AND THEY SHALL NOT BE STORED IN AN UPRIGHT POSITION. 4.5.2. HANDLING- HANDLING DEVICES SHALL BE PERMITTED IN EACH PRECAST ELEMENT FOR THE PURPOSE OF HANDLING AND SETTING. SPREADER BEAMS MAY BE REQUIRED FOR THE LIFTING OF PRECAST CONCRETE BRIDGE ELEMENTS TO PRECLUDE DAMAGE FROM BENDING OR TORSION FORCES. 4.5.3. DELIVERY- PRECAST CONCRETE ELEMENTS MUST NOT BE SHIPPED UNTIL THE CONCRETE HAS ATTAINED THE SPECIFIED DESIGN COMPRESSIVE STRENGTH, OR AS DIRECTED BY THE DESIGN ENGINEER. PRECAST CONCRETE ELEMENTS MAY BE UNLOADED AND PLACED ON THE GROUND AT THE SITE UNTIL INSTALLED. STORE ELEMENTS USING TIMBER SUPPORTS AS APPROPRIATE. 4.6. QUALITY ASSURANCE- THE PRECASTER SHALL DEMONSTRATE ADHERENCE TO THE STANDARDS SET FORTH IN THE NPCA QUALITY CONTROL MANUAL. THE PRECASTER SHALL MEET EITHER SECTION 4e.1 OR 4.6.2 4.6.1. CERTIFICATION -THE PRECASTER SHALL BE CERTIFIED BY THE PRECASTIPRESTRESSED CONCRETE INSTITUTE PLANT CERTIFICATION PROGRAM OR THE NATIONAL PRECAST CONCRETE ASSOCIATION'S PLANT CERTIFICATION PROGRAM PRIOR TO AND DURING PRODUCTION OF THE PRODUCTS COVERED BY THIS SPECIFICATION. 4.6.2. QUALIFICATIONS TESTING AND INSPECTION 4.6.2.1. THE PRECASTER SHALL HAVE BEEN IN THE BUSINESS OF PRODUCING PRECAST CONCRETE PRODUCTS SIMILAR TO THOSE SPECIFIED FOR A MINIMUM OF THREE YEARS. HE SHALL MAINTAIN A PERMANENT QUALITY CONTROL DEPARTMENT OR RETAIN AN INDEPENDENT TESTING AGENCY ON A CONTINUING BASIS. THE AGENCY SHALL ISSUE A REPORT, CERTIFIED BY LICENSED ENGINEER, DETAILING THE ABILITY OF THE PRECASTER TO PRODUCE QUALITY PRODUCTS CONSISTENT WITH INDUSTRY STANDARDS. 4.6.2.2. THE PRECASTER SHALL SHOW THAT THE FOLLOWNG TESTS ARE PERFORMED IN ACCORDANCE WITH THE ASTM STANDARDS INDICATED. TESTS SHALL BE PERFORMED AS INDICATED IN SECTION 6 OF THESE SPECIFICATIONS. 4.61.2.1. AIR CONTENT: U31 OR C173 4.61.21. COMPRESSIVE STRENGTH: C31,C39,C497 4.6.2.3. THE PRECASTER SHALL PROVIDE DOCUMENTATION DEMONSTRATING COMPLIANCE WITH THIS SECTION TO CONTECHO ENGINEERED SOLUTIONS AT REGULAR INTERVALS OR UPON REQUEST. 4.6.2.4. THE OWNER MAY PLACE AN INSPECTOR IN THE PLANT WHEN THE PRODUCTS COVERED BY THIS SPECIFICATION ARE BEING MANUFACTURED. 4.6.3. DOCUMENTATION -THE PRECASTER SHALL SUBMIT PRECAST PRODUCTION REPORTS TO CONTECHT) ENGINEERED SOLUTIONS AS REQUIRED. 5. PERMISSIBLE VARATIONS Sl1 BRIDGE UNITS 5.1.1.INTERNAL DIMENSIONS -THE INTERNAL DIMENSION SHALL VARY NOT MORE THAN 1% FROM THE DESIGN DIMENSIONS NOR MORE THAN US- WHICHEVER IS LESS. 5.13. SLAB AND WALL THICKNESS -THE SLAB AND WALL THICKNESS SHALL NOT BE LESS THAN THAT SHOWN IN THE DESIGN BY MORE THAN Ya A THICKNESS MORE THAN THAT REQUIRED IN THE DESIGN SHALL NOT BE CAUSE FOR REJECTION. 5.1.3. LENGTH OF OPPOSITE SURFACES - VARIATIONS IN LAYING LENGTHS OF TWO OPPOSITE SURFACES OF THE BRIDGE UNIT SHALL NOT BE MORE THAN),' IN ANY SECTION, EXCEPT WHERE BEVELED ENDS FOR LAYING OF CURVES ARE SPECIFIED BY THE PURCHASER. 5.1 A. LENGTH OF SECTION -THE UNDERRUN IN LENGTH OF A SECTION SHALL NOT BE MORE THAN)," IN ANY BRIDGE UNIT. 5.1.5. POSITION OF REINFORCEMENT -THE MAXIMUM VARIATION IN POSITION OF THE REINFORCEMENT SHALL BE t),". IN NO CASE SHALL THE COVER OVER THE REINFORCEMENT BE LESS THAN I& FOR THE OUTSIDE CIRCUMFERENTIAL STEEL OR BE LESS THAN V FOR THE INSIDE CIRCUMFERENTIAL STEEL AS MEASURED TO THE EXTERNAL OR INTERNAL SURFACE OF THE BRIDGE. THESE TOLERANCES OR COVER REQUIREMENTS DO NOT APPLY TO MATING SURFACES OF THE JOINTS. 5 L6. AREA OF REINFORCEMENT- THE AREAS OF STEEL NTECH0 ENGImam Souffiom LLC www.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 800-338-1122 513-645-7000 513 6457993 FAX FABRICATION DRAWING REINFORCEMENT SHALL BE THE DESIGN STEEL AREAS AS SHOWN IN THE MANUFACTURER'S SHOP DRAWINGS. STEEL AREAS GREATER THAN THOSE REQUIRED SHALL NOT BE CAUSE FOR REJECTION. THE PERMISSIBLE VARIATION IN DIAMETER OF ANY REINFORCEMENT SHALL CONFORM TO THE TOLERANCES PRESCRIBED IN THE ASTM SPECIFICATION FOR THAT TYPE OF REINFORCEMENT. 5.2. WINGWALLS&HEADWALLS 5.2A. WALL THICKNESS- THE WALL THICKNESS SHALL NOT VARY FROM THAT SHOWN IN THE DESIGN BY MORE THAN)4". 5.2.2. LENGTHIHEIGHT OF WALL SECTIONS -THE LENGTH AND HEIGHT OF THE WALL SHALL NOT VARY FROM THAT SHOWN IN THE DESIGN BY MORE THAN),'. 5.2.3. POSITION OF REINFORCEMENT -THE MAXIMUM VARIATION IN THE POSITION OF THE REINFORCEMENT SHALL BE 4)V. IN NO CASE SHALL THE COVER OVER THE REINFORCEMENT BE LESS THAN 1),". 5.2A.SIZE OF REINFORCEMENT -THE PERMISSIBLE VARIATION IN DIAMETER OF ANY REINFORCING SHALL CONFORM TO THE TOLERANCES PRESCRIBED IN THE ASTM SPECIFICATION FOR THAT TYPE OF REINFORCING. STEEL AREA GREATER THAN THAT REQUIRED SHALL NOT BE CAUSE FOR REJECTION. 5.3. FOUNDATION UNITS SSA. WALL THICKNESS -THE WALL THICKNESS SHALL NOT VARY FROM THAT SHOWN IN THE DESIGN BY MORE THAN V. 5.3.2. LENGTH/ HEIGHTAMDTH OF FOUNDATION SECTIONS -THE LENGTH, HEIGHT AND WIDTH OF THE FOUNDATION UNITS SHALL NOT VARY FROM THAT SHOWN IN THE DESIGN BY MORE THAN Yt". 5.3.3. POSITION OF REINFORCEMENT -THE MAXIMUM VARIATION IN THE POSITION OF THE REINFORCEMENT SHALL BE t4". IN NO CASE SHALL THE COVER OVER THE REINFORCEMENT BE LESS THAN 1),". 5.3A.SIZE OF REINFORCEMENT -THE PERMISSIBLE VARIATION IN DIAMETER OF ANY REINFORCING SHALL CONFORM TO THE TOLERANCES PRESCRIBED IN THE ASTM SPECIFICATION FOR THAT TYPE OF REINFORCING. STEEL AREA GREATER THAN THAT REQUIRED SHALL NOT BE CAUSE FOR REJECTION. 6. TESTING! INSPECTION 6.1. TESTING &1.1. TYPE OF TEST SPECIMEN -CONCRETE COMPRESSIVE STRENGTH SHALL BE DETERMINED FROM COMPRESSION TESTS MADE ON CYLINDERS OR CORES. FOR CYLINDER TESTING, A MINIMUM OF 4 CYLINDERS SHALL BE TAKEN FOR EACH BRIDGE ELEMENT. FOR CORE TESTING, A MINIMUM OF 2 CORES SHALL BE TAKEN FOR EACH BRIDGE ELEMENT. EACH ELEMENT SHALL BE CONSIDERED SEPARATELY FOR THE PURPOSE OF TESTING AND ACCEPTANCE. 6.1.2. COMPRESSION TESTING -CYLINDERS SHALL BE MADE AND TESTED AS PRESCRIBED BY THE ASTM C39 SPECIFICATION. CYLINDERS SHALL BE CURED IN THE SAME ENVIRONMENT AS THE BRIDGE ELEMENTS. CORES SHALL BE OBTAINED AND TESTED FOR COMPRESSIVE STRENGTH FROM EACH ELEMENT IN ACCORDANCE WITH THE PROVISIONS OF THE ASTM C42 SPECIFICATION. 6A.3. ACCEPTABILITY OF CYLINDER TESTS -WHEN THE AVERAGE COMPRESSIVE STRENGTH OF ALL CYLINDERS TESTED IS EQUAL TO OR GREATER THAN THE DESIGN COMPRESSIVE STRENGTH, AND NOT MORE THAN 10%OF THE CYLINDERS TESTED HAVE A COMPRESSIVE STRENGTH LESS THAN THE DESIGN CONCRETE STRENGTH, AND NO CYLINDER TESTED HAS A COMPRESSIVE STRENGTH LESS THAN 90%OF THE REQUIRED CONCRETE STRENGTH, THEN THE ELEMENT SHALL BE ACCEPTED. MEN THE COMPRESSIVE STRENGTH OF THE CYLINDERS TESTED DOES NOT CONFORM TO THESE ACCEPTANCE CRITERIA, THE ACCEPTABILITY OF THE ELEMENT MAY BE DETERMINED AS DESCRIBED IN SECTION 6.1.4, BELOW. 6.1.4.ACCEPTABILITY OF CORE TESTS-THECOMPRESSIVE STRENGTH OF THE CONCRETE IN A BRIDGE ELEMENT IS ACCEPTABLE WHEN EACH CORE TEST STRENGTH IS EQUAL TO OR GREATER THAN THE DESIGN CONCRETE STRENGTH. WHEN THE COMPRESSIVE STRENGTH OF A CORE TESTED IS LESS THAN THE DESIGN CONCRETE STRENGTH, THE PRECAST ELEMENT FROM WHICH THAT CORE WAS TAKEN MAY BE RE -CORED. WHEN THE COMPRESSIVE STRENGTH OF THE RE -CORE IS EQUAL TO OR GREATER THAN THE DESIGN CONCRETE STRENGTH, THE COMPRESSIVE STRENGTH OF THE CONCRETE IN THAT BRIDGE ELEMENT IS ACCEPTABLE. 6.1 A.1. WHEN THE COMPRESSIVE STRENGTH OF ANY RECORE IS LESS THAN THE DESIGN CONCRETE STRENGTH, THE PRECAST ELEMENT FROM WHICH THAT CORE WAS TAKEN SHALL BE REJECTED. n / PHILIP ALAN CREAMER Lie. No. 45345 6.1.4.2. PLUGGING CORE HOLES -THE CORE HOLES SHALL BE PLUGGED AND SEALED BY THE MANUFACTURER IN A MANNER SUCH THAT THE ELEMENTS WILL MEET ALL OF THE TEST REQUIREMENTS OF THIS SPECIFICATION. PRECAST ELEMENTS SO SEALED SHALL BE CONSIDERED SATISFACTORY FOR USE. 6.1A.3. TEST EQUIPMENT- EVERYMANUFACTURER FURNISHING PRECAST ELEMENTS UNDER THIS SPECIFICATION SHALL FURNISH ALL FACILITIES AND PERSONNEL NECESSARY TO CARRY OUT THE TEST REQUIRED. 6.2. INSPECTION -THE QUALITY OF MATERIALS. THE PROCESS OF MANUFACTURE, AND THE FINISHED PRECAST ELEMENTS SHALL BE SUBJECT TO INSPECTION BY THE PURCHASER. 7. JOINTS THE BRIDGE UNITS SHALL BE PRODUCED WITH FLAT BUTT ENDS. THE ENDS OF THE BRIDGE UNITS SHALL BE SUCH THAT WHEN THE SECTIONS ARE LAID TOGETHER THEY WILL MAKE A CONTINUOUS LINE WITH A SMOOTH INTERIOR FREE OF APPRECIABLE IRREGULARITIES, ALL COMPATIBLE WITH THE PERMISSIBLE VARIATIONS IN SECTION 5, ABOVE. THE JOINT WIDTH BETWEEN ADJACENT PRECAST UNITS SHALL NOT EXCEED Y". 8. WORKMANSHIP! FINISH THE BRIDGE UNITS, WINGWALLS. HEADWALLS AND FOUNDATION UNITS SHALL BE SUBSTANTIALLY FREE OF FRACTURES. THE ENDS OF THE BRIDGE UNITS SHALL BE NORMAL TO THE WALLS AND CENTERLINE OF THE BRIDGE SECTION, WITHIN THE LIMITS OF THE VARIATIONS GIVEN IN SECTION 5, ABOVE, EXCEPT WHERE BEVELED ENDS ARE SPECIFIED. THE FACES OF THE WINGWALLS AND HEADWALLS SHALL BE PARALLEL TO EACH OTHER, WITHIN THE LIMITS OF VARIATIONS GIVEN IN SECTION 5, ABOVE. THE SURFACE OF THE PRECAST ELEMENTS SHALL BE A SMOOTH STEEL FORM OR TROWELED SURFACE. TRAPPED AIR POCKETS CAUSING SURFACE DEFECTS SHALL BE CONSIDERED AS PART OF A SMOOTH, STEEL FORM FINISH. 9. REPAIRS PRECAST ELEMENTS MAY BE REPAIRED, IF NECESSARY, BECAUSE OF IMPERFECTIONS IN MANUFACTURE OR HANDLING DAMAGE AND WILL BE ACCEPTABLE IF, IN THE OPINION OF THE PURCHASER, THE REPAIRS ARE SOUND, PROPERLY FINISHED AND CURED, AND THE REPAIRED SECTION CONFORMS TO THE REQUIREMENTS OF THIS SPECIFICATION. 10.REJECTION THE PRECAST ELEMENTS SHALL BE SUBJECT TO REJECTION ON ACCOUNT OF ANY OF THE SPECIFICATION REQUIREMENTS. INDIVIDUAL PRECAST ELEMENTS MAY BE REJECTED BECAUSE OF ANY OF THE FOLLOWING: 10.1.FRACTURES OR CRACKS PASSING THROUGH THE WALL, EXCEPT FOR A SINGLE END CRACK THAT DOES NOT EXCEED ONE HALF THE THICKNESS OF THE WALL. 10.2.DEFECTS THAT INDICATE PROPORTIONING, MIXING, AND MOLDING NOT IN COMPLIANCE WITH SECTION 4 OF THESE SPECIFICATIONS. 10.3.11ONEYCOMBED OR OPEN TEXTURE. 10.4.DAMAGED ENDS, WHERE SUCH DAMAGE WOULD PREVENT MAKING A SATISFACTORY JOINT. Digitally signed by y:. Philip A. Creamer Date: 2022.03.10 14:15:48-05'00' QIECTNo. SEMNo, DATE: 689029 010 3/10/2022 PLEASANT GREEN SUBDIVISION y JMF JCH CHECKED: APPROVED: SPS PAC ALBEMARLE COUNTY, VIRGINIA SHEET NO.: S25 DE S� SPECIFICATIONS FOR MANUFACTURE AND INSTALLATION OF CON/SPAN® O-SERIES BRIDGE SYSTEMS (CONT1 11. MARKING EACH UNIT SHALL BE CLEARLY MARKED BY WATERPROOF PAINT. THE FOLLOWING SHALL BE SHOWN ON THE INSIDE OF THE VERTICAL LEG OF THE BRIDGE SECTION: BRIDGE SPAN x BRIDGE RISE DATE OF MANUFACTURE NAME OR TRADEMARK OF THE MANUFACTURER 1Z INSTALLATION PREPARATION TO ENSURE CORRECT INSTALLATION OF THE PRECAST CONCRETE BRIDGE SYSTEM, CARE AND CAUTION MUST BE EXERCISED IN FORMING THE SUPPORT AREAS FOR BRIDGE UNITS, HEADWALL, AND WINGWAL ELEMENTS. EXERCISING SPECIAL CARE WILL FACILITATE THE RAPID INSTALLATION OF THE PRECAST COMPONENTS. 12A. FOOTINGS DO NOT OVER EXCAVATE FOUNDATIONS UNLESS DIRECTED BY SITE SOIL ENGINEER TO REMOVE UNSUITABLE SOIL. THE SITE SOILS ENGINEER SHALL CERTIFY THAT THE BEARING CAPACITY MEETS OR EXCEEDS THE FOOTING DESIGN REQUIREMENTS, PRIOR TO THE CONTRACTOR POURING OF THE FOOTINGS. THE BRIDGE UNITS AND WINGWALLS SHALL BE INSTALLED ON EITHER PRECAST OR CAST -IN -PLACE CONCRETE FOOTINGS. THE SIZE AND ELEVATION OF THE FOOTINGS SHALL BE AS DESIGNED BY THE ENGINEER. A KEYWAY SHALL BE FORMED IN THE TOP SURFACE OF THE BRIDGE FOOTING AS SPECIFIED ON THE PLANS. NO KEYWAY IS REQUIRED IN THE WINGWALL FOOTINGS, UNLESS OTHERWISE SPECIFIED ON THE PLANS. THE FOOTINGS SHALL BE GIVEN A SMOOTH FLOAT FINISH AND SHALL REACH A COMPRESSIVE STRENGTH OF 2,000 PSI BEFORE PLACEMENT OF THE BRIDGE AND WWGWALL ELEMENTS. BACKFILLING SHALL NOT BEGIN UNTIL THE FOOTING HAS REACHED THE FULL DESIGN COMPRESSIVESTRENGTH. THE FOOTING SURFACE SHALL BE CONSTRUCTED IN ACCORDANCE WITH GRADES SHOWN ON THE PLANS. WHEN TESTED WITH A 10'-0" STRAIGHT EDGE, THE SURFACE SHALL NOT VARY MORE THAN y" IN 104F. IF A PRECAST CONCRETE FOOTING IS USED, THE CONTRACTOR SHALL PREPARE AP THICK BASE LAYER OF COMPACTED GRANULAR MATERIAL THE FULL WIDTH OF THE FOOTING PRIOR TO PLACING THE PRECAST FOOTING. THE FOUNDATIONS FOR PRECAST CONCRETE BRIDGE ELEMENTS AND WINGWALLS MUST BE CONNECTED BY REINFORCEMENT TO FORM ONE MONOLITHIC BODY. EXPANSION JOINTS SHALL NOT BE USED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONSTRUCTION OF THE FOUNDATIONS PER THE PLANS AND SPECIFICATIONS. 13. INSTALLATION 13.1. GENERAL-THEINSTALLATIONOFTHEPRECASTCONCRETE ELEMENTS SHALL BE AS EXPLAINED IN THE PUBLICATION COWMAN BRIDGE SYSTEMS INSTALLATION HANDBOOK. 13.1.1. LIFTING -IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT A CRANE OF THE CORRECT LIFTING CAPACITY IS AVAILABLE TO HANDLE THE PRECAST CONCRETE UNITS. THIS CAN BE ACCOMPLISHED BY USING THE WEIGHTS GIVEN FOR THE PRECAST CONCRETE COMPONENTS AND BY DETERMINING THE LIFTING REACH FOR EACH CRANE UNIT. SITE CONDITIONS MUST BE CHECKED WELL IN ADVANCE OF SHIPPING TO ENSURE PROPER CRANE LOCATION AND TO AVOID MY LIFTING RESTRICTIONS. THE LIFT ANCHORS OR HOLES PROVIDED IN EACH UNIT ARE THE ONLY MEANS TO BE USED TO LIFT THE ELEMENTS. THE PRECAST CONCRETE ELEMENTS MUST NOT BE SUPPORTED OR RAISED BY OTHER MEANS THAN THOSE GIVEN IN THE MANUALS AND DRAWINGS WTHOUT WRITTEN APPROVAL FROM CONTECHO ENGINEERED SOLUTIONS. 13.1.2. CONSTRUCTION EQUIPMENT WEIGHTRESTRICTIONS-IN NO CASE SHALL EQUIPMENT OPERATING IN EXCESS OF THE DESIGN LOAD (HL-93) BE PERMITTED OVER THE BRIDGE UNITS UNLESS APPROVED BY CONIMCHO ENGINEERED SOLUTIONS. 13.12.1. IN THE IMMEDIATE AREA OF THE BRIDGE UNITS, THE FOLLOWING RESTRICTIONS FOR THE USE OF HEAVY CONSTRUCTION MACHINERY DURING BACKFILLING OPERATIONS APPLY: • NO CONSTRUCTION EQUIPMENT SHALL CROSS THE BARE PRECAST CONCRETE BRIDGE UNIT • AFTER THE COMPACTED FILL LEVEL HAS REACHED A MINIMUM OF C OVER THE CROWN OF THE BRIDGE, CONSTRUCTION EQUIPMENT WITH A WEIGHT OF LESS THAN 10 TONS MAY CROSS THE BRIDGE. • AFTER THE COMPACTED FILL LEVEL HAS REACHED A MINIMUM OF T-0- OVER THE CROWN OF THE BRIDGE, CONSTRUCTION EQUIPMENT WITH A WEIGHT OF LESS THAN 30 TONS MAY CROSS THE BRIDGE. • AFTER THE COMPACTED FILL LEVEL HAS REACHED THE DESIGN COVER, OR 2'-0" MINIMUM, OVER THE CROWN OF THE PRECAST CONCRETE BRIDGE, CONSTRUCTION EQUIPMENT WITHIN THE DESIGN LOAD LIMITS FOR THE ROAD MAY CROSS THE PRECAST CONCRETE BRIDGE. 132. LEVELING PAD/SHIMS- THE BRIDGE UNITS AND WINGWALLS SHALL BE SET ON HARDBOARD SHIMS CONFORMING TO ASTM D1037 OR PLASTIC SHIMS (DAYTON SUPERIOR PSO, PS1 OR APPROVED EQUAL) MEASURING 5" x 5', MINIMUM, UNLESS SHOWN OTHERWISE ON THE PLANS. A MINIMUM GAP OF & SHALL BE PROVIDED BETWEEN THE FOOTING AND THE BOTTOM OF THE BRIDGE'S VERTICAL LEGS OR THE BOTTOM OF THE WINGWALL. ALSO, A SUPPLY OF y', & AND K" THICK HARDBOARD OR PLASTIC SHIMS FOR VARIOUS SHIMMING PURPOSES SHALL BE ON SITE. 13S. PLACEMENT OF BRIDGE UNITS- THE BRIDGE UNITS SHALL BE PLACED AS SHOWN ON THE ENGINEERS PLAN DRAWINGS. SPECIAL CARE SHALL BE TAKEN IN SETTING THE ELEMENTS TO THE TRUE LINE AND GRADE. THE JOINT WIDTH BETWEEN ADJACENT PRECAST UNITS SHALL NOT EXCEED 31". 13A. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN THE STRUCTURE SPAN DURING ALL PHASES OF INSTALLATION. DUE TO THE ARCH SHAPE, BRIDGE ELEMENTS WILL TEND TO SPREAD UNDER SELF -WEIGHT. IT IS IMPERATIVE THAT ANY LATERAL SPREADING OF THE BRIDGE ELEMENTS BE AVOIDED DURING AND AFTER THEIR PLACEMENT. GENERALLY, HORIZONTAL CABLE TIES OR TIE RODS ARE SHIPPED IN THE LARGER BRIDGE ELEMENTS TO ASSIST IN PREVENTING THIS SPREADING. CABLE TIES IE RODS SHALL NOT BE REMOVED UNTILL BRIDGE UNITS ARE GROUTED AND GROUT HAS CURED. IT IS RECOMMENDED THAT TEMPORARY HARDWOOD BLOCKS BE USED IN CONJUNCTION WITH THE CABLE TIESrTIE RODS TO MAINTAIN SPAN. IF, HOWEVER, DUE TO SITE RESTRICTIONS, THESE CABLE TIES/ IE RODS MUST BE REMOVED PRIOR TO PLACEMENT OF THE BRIDGE ELEMANTS, THE CONTRACTOR MUST NOTIFY CONTECH (MANUFACTURER) AND REQUEST SUGGESTED INSTALLATION PROCEDURE. IN ADDITION, IF THE CABLE TIESrFE RODS MUST BE REMOVED PRIOR TO SETTING ARCH UNITS, THE FOLLOWING QUALITY CONTROL PROCEDURE MUST BE FOLLOWED: 1) FIND 'MEASURED SPAN" UPON ARCH UNITS DELIVERY TO SITE, PRIOR TO LIFTING FROM TRUCK AND REMOVING CABLE TIESrFE RODS. "MEASURED SPAN' SHALL BE THE AVERAGE OF (3) SPAN MEASUREMENTS ALONG THE LAY LENGTH OF THE ARCH UNIT. 2) AFTER SETTING OF BRIDGE UNIT ON THE FOUNDATION, VERIFY THE SPAN. THIS 'INSTALLED SPAN MEASUREMENT" SHALL NOT EXCEED THE MAXIMUM OF: A) THE NOMINAL SPAN ♦& OR B)THE -MEASURED SPAN" IF THE 'INSTALLED SPAN MEASUREMENT' EXCEEDS THIS AMOUNT, THE ARCH UNIT SHALL BE LIFTED AND RE -SET UNTIL THE "INSTALLED SPAN MEASUREMENT" MEETS THE LIMITS. 13.5. PLACEMENT OF WWGWALLS,HEADWALLSAND FOUNDATION UNITS - THE WINGWALLS, HEADWALLS AND FOUNDATIONS SHALL BE PLACED AS SHOWN ON THE PLAN DRAWINGS. SPECIAL CARE SHALL BE TAKEN IN SETTING THE ELEMENTS TO THE TRUE LINE AND GRADE. 13.6. JOINT PROTECTION AND SUBSURFACE DRAINAGE 13A.L EXTERNAL PROTECTION OF JOINTS- THE BUTT JOINT MADE BY JOINT WRAP TO BE USED SHALL BE APPLIED FOR A MINIMUM WIDTH OF W ON EACH SIDE OF THE JOINT. THE EXTERNAL WRAP SHALL BE CS212 BY CONCRETE SEALANTS INC.. EZ-WRAP RUBBER BY PRESS -SEAL GASKET CORPORATION, SEAL WRAP BY MAR MAC MANUFACTURING CO. INC. OR APPROVED EQUAL. THE JOINT SHALL BE COVERED CONTINUOUSLY FROM THE BOTTOM OF ONE BRIDGE SECTION LEG, ACROSS THE TOP OF THE BRIDGE AND TO THE OPPOSITE BRIDGE SECTION LEG. ANY LAPS THAT RESULT IN THE JOINT WRAP SHALL BE A MINIMUM OF 6" LONG WITH THE OVERLAP RUNNING DOWNHILL. 13e.Z IN ADDITION TO THE JOINTS BETWEEN BRIDGE UNITS THEJOINT BETWEEN THE END BRIDGE UNIT AND THE HEADWALL SHALL ALSO BE SEALED AS DESCRIBED ABOVE. IF PRECAST WINGWALLS ARE USED, THE JOINT BETWEEN THE END BRIDGE UNIT AND THE WINGWALL SHALL BE SEALED WITH A Z-0" STRIP OF FILTER FABRIC. ALSO, IF LIFT HOLES ARE FORMED IN THE BRIDGE UNITS, THEY SHALL BE PRIMED AND COVERED WITH A 9" x W SQUARE OF JOINT WRAP. 13.6.3. DURING THE BACKFLLING OPERATION, CARE SHALL BE TAKEN TO KEEP THE JOINT WRAP IN ITS PROPER LOCATION OVER THE JOINT. 13A.4. SUBSOIL DRAINAGE SHALL BE AS DIRECTED BY THE ENGINEER. 13.7. GROUTING 13.7.1. GROUTING SHALL NOT BE PERFORMED WHEN TEMPERATURES ARE EXPECTED TO GO BELOW 35" FOR A PERIOD OF 72 HOURS. GROUTING SHOULD BE COMPLETED AS SOON AS PRACTICAL AFTER PRECAST ARCHES HAVE BEEN INSTALLED. FILL THE BRIDGETOUNDATION KEYWAY WITH CEMENT GROUT (PORTLAND CEMENT AND WATER OR CEMENT MORTAR COMPOSED OF PORTLAND CEMENT, ND AND WATER WITH A MINIMUM V COMPRESSIVE C ,SA I B4N CO 55 STRENGTH A 3000 OUNPSI.VIBRATEASREQUIRED TO ENSURE THAT THE ENTIRE KEY ELEMENTS THE BRIDGE ELEMENT IS COMPLETELY FILLED. IF BRIDGEELEMENTS HAVE BEEN SET TEMPORARY TIES (CABLES. BARS, ETC.) GROUT MUST ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 1500 PSI BEFORE TIES MAY BE REMOVED. 13.7.3. Li LING TSH ECTIMEAMAXI RECEG RELATE BEFIL D 13.].3. LIFTING AND ERECTION ANCHOR RECESSES SHALL BE FILIED WITH GROUT. 133.AFTER GROUT HAS REACHED ITS DESIGN STRENGTH THE TEMPORARY HARDWOOD WEDGES SHALL BE REMOVED AND THEIR HOLES FILLED WITH GROUT. 13.8. BACKFILL 13.8.1. DO NOT PERFORM BACKFILLING DURING WET OR FREEZING WEATHER. 13.8.E NENTSUNIILTHEYHA BEEN AGAINSED BY STRUCTURAL ELEMENTSUNTILTHBHAVEIDERED AS ALL BY THE ENGINEER. 13.8.A BACKFIUL EMBANALLBECONSIDERED AS ALL REPLACEDNCRETE ON ANDNEW EMBANKOJECT CONSTRUCTION TO THE PRECAST CONCRETE ELEMENTS. THE PROJECT CONSTRUCTION AND MATERIAL SPECIFICATIONS, TINCLUDE THE SPECIFICATIONS FOR S EXCAVATION FOR STRUCTURES AND ROADWAY EXCAVATION AND EMBANKMENT CONSTRUCTION, SHALLAPPLV EXCEPT AS MODIFIED IN THIS SECTION. 13.BACKFILL ZONES: • IN • IN -SITU SOIL • ZONE A: CONSTRUCTED EMBANKMENT OR OVERFILL. • ZONE B: FILL THAT IS DIRECTLY ASSOCIATED WITH PRECAST CONCRETE BRIDGE INSTALLATION. • ZONE C: ROAD STRUCTURE. 1ES 13..5. REQUIRED IL-NATUACKFILL RAL GROUND 13.8.5.1. INSITU SOIL- NATURAL GROUND IS TO BE SUFFICIENTLY STABLE TO ALLOW EFFECTIVE SUPPORTTO THE PRECAST CONCRETE OUSTING BRIDGE UNITS. GUIDE, THE EXISTING NATURAL GROUND SIMILAR SHOULD BEOF SIMILARQUALITY LATERAL DI DENSITY TO ZONE I MATERIAL FOR MINIMUM LATERAL DIMENSION OF ONE BRIDGE SPAN OUTSIDE OF THE BRIDGE FOOTING. 13.8.5.2. ZONE AA REQUIRES FILL MATERIAL WITH SPECIFICATIONS AND COMPACTING PROCEDURES EQUAL TO THAT FOR NORMAL ROAD EMBANKMENTS. o,'." re' 'n_'m jMARKI DATE I REVISION DESCRIPTION 13.8.5S. ZONE B -GENERALLY, SOILS SHALL BE REASONABLY FREE OF ORGANIC MATTER, AND, NEAR CONCRETE SURFACES, FREE OF STONES LARGER THAN T IN DIAMETER SEE CHARTS FOR 13S.5A. ZONE C -ZONE C IS THE ROAD SECTION OF GRAVEL, ASPHALT OR CONCRETE BUILT IN COMPLIANCE WITH LOCAL ENGINEERING PRACTICES. 13.8.5.5. GEOTECHNICAL ENGINEER SHALL REVIEW GRADATIONS OF ALL INTERFACING MATERIALS AND, IF NECESSARY, RECOMMEND GEOTEXTILE FILTER FABRIC (PROVIDED BY CONTRACTOR) 13.8AL PLACING AND COMPACTING BACKFILL DUMPING FOR BACKFILLING IS NOT ALLOWED ANY NEARER THAN 3'-0" FROM THE BRIDGE LEG. THE FILL MUST BE PLACED AND COMPACTED IN LAVERS NOT EXCEEDING 8'. THE MAXIMUM DIFFERENCE IN THE SURFACE LEVELS OF THE FILL ON OPPOSITE SIDES OF THE BRIDGE MUST NOT EXCEED 2'-0". THE FILL BEHIND WINGWALLS MUST BE PLACED AT THE SAME TIME AS THAT OF THE BRIDGE FILL. IT MUST BE PLACED IN PROGRESSIVELY PLACED HORIZONTAL LAYERS NOT EXCEEDING W PER LAYER. THE BACKFILL OF ZONE B SHALL BE COMPACTED TO A MINIMUM DENSITY OF 95%OF THE STANDARD PROCTOR, AS REQUIRED BY AASHTO T-99. SOIL WITHIN 1'-0" OF CONCRETE SURFACES SHALL BE HAND -COMPACTED. ELSEWHERE, USE OF ROLLERS IS ACCEPTABLE. IF VIBRATING ROLLER -COMPACTORS ARE USED, THEY SHALL NOT BE STARTED OR STOPPED WITHIN ZONE B AND THE VIBRATION FREQUENCY SHOULD BE AT LEAST 30 REVOLUTIONS PER SECOND. THE BACKFILL MATERIAL AND COMPACTING BEHIND WINGWALLS SHALL SATISFY THE CRITERIA FOR THE BRIDGE BACKFILL. ZONE B. BACKRUL AGAINST A WATERPROOFED SURFACE SHALL BE PLACED CAREFULLY TO AVOID DAMAGE TO THE WATERPROOFING MATERIAL. 13AT BRIDGE UNITS FOR FILL HEIGHTS OVER 12 FEET (AS MEASURED FROM TOP CROWN OF BRIDGE TO FINISHED GRADE), NO BACKFILLING MAY BEGIN UNTIL A BACKFILL COMPACTION TESTING PLAN HAS BEEN COORDINATED WITH AND APPROVED BY CONTECM ENGINEERED SOLUTIONS. 13JBIL WINGWALLS BACKFILL IN FRONT OF WINGWALLS SHALL BE CARRIED TO GROUND LINES SHOWN IN THE PLANS. 13.8.9. MONITORING THE CONTRACTOR SHALL CHECK SETTLEMENTS AND HORIZONTAL DISPLACEMENT OF FOUNDATION TO ENSURE THAT THEY ARE WITHIN THE ALLOWABLE LIMIT PROVIDED BY THE ENGINEER. THESE MEASUREMENTS SHOULD GIVE AN INDICATION OF THE SETTLEMENTS AND DEFORMATIONS ALONG THE LENGTH OF THE FOUNDATIONS. THE FIRST MEASUREMENT SHOULD TAKE PLACE AFTER THE ERECTION OF ALL PRECAST BRIDGE SYSTEM ELEMENTS, A SECOND AFTER COMPLETION OF BACKFILLING, AND A THIRD BEFORE OPENING OF THE BRIDGE TO TRAFFIC. FURTHER MEASUREMENTS MAY BE MADE ACCORDING TO LOCAL CONDITIONS. NTEC�• ENCIINEEND SOl1IilOWS QC www.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 8DO-338-1122 513645-7000 513 6457993 FAX VARIES BY ANCHOR TYPE A= 3'-2" B=4'-1• C= 5'-1' FINISHED GRADE D=6'-1" 1'-or COMPACTED MATERIAL E-T-1' MIN. (SAME AS UNIT BACKFILL) F=8'-1" PRECAST Oo �°jB 2' abodo -\ WINGWALL �°m$�° o2° o W�4 epodo ° moo. O ppa° Ww° O9b o IN -SITU SOIL _ GROUT 15M�SPAL O-SERIES.. FABRICATION DRAWING ACCEPTABLE SOILS FOR USE IN ZONE B BACKFILL PERCENTPASSING CXPRPCTER C£ OVCTON TYPICAL AABHTO AASHTO USSIEVENo. PASSING ND 4TSIEY£ USCS MATERIALS GROUP SUBGROUP SOIL DESRIPTION *10 >!40 412DO TOLD nAS LIMITIMIT ING. GIN, GP, SP A-ta 50 MAX 30 MAX 15 MAX 6 MAX LARGELY GRAVEL BUT CAN At INCLUDE SAND AND FINES GM, SW, A-16 50 MAX 25 MAX 6 MAX GRAVELLY SAND OR GRADED SP. SM SAND, MAY INCLUDE FINES GM, SM, ML, A 2J 35 MAX 40 MAX 10 MAX SANDS, GRAVELS WITH LOW- SP, 6, PLASTICITY SILT FINES BE, GC, GM A-2-5 35 MAX 41 MIN LOMAX SANDS, GRAVELS WITH PLASTIC SILT FINES SP, SM, BIN iFINESANDS A3 51 MIN LOMAX Ow pIASTIC ML. SM, SC A4 36 MIN 1 40 MAX LOMAX I LOW-COMPRESSIBILTY SILTS +Pd A B / o� IN -SITU SOIL 7 G' 1/ FINISHED GRADE TO ROADWAY BASE FINISH GRADEORTMIN. LIMITS OF CRITICAL BACKFILL ZONE B 08 A 4 B e� o4l, .4 IN SITU L SOIL 7 SPAN FILL HEIGHT ACCEPTABLEMATERIAL INSIDE ZONE B s 24'-0" z 12'-0" Al, A3 s 24'-0' <12'-0" A1, A2, A3,M > 24'-0' ALL Al. A3 BACKFILL REQUIREMENTS VARIES SEE LIMITS OF FABRICATION EXCAVATION / DRAWINGS ZONE A TIE RODS LIMITS OF CRITICAL BACKFILL ZONE(CB.Z.) Digitally signed by AIILIP y Philip A. Creamer AY55. ic.No.MAIM!", Date:2022.03.10 Lic. No.45345 q O I 14:16:02 05I 00 PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA QIECTNo.: SEO.N°.: DATE: 689029 010 3/10/2022 SIGNED: DRAM: JMF JCH ECKED: APPROVED: SPS PAC EET NO.: S26 DF S26