Loading...
HomeMy WebLinkAboutARB202000035 Plan - Approved 2022-04-27ARCHITECT OF RECORD: 22'-0" AFF T.O. PARAPET 18'-0" AFF T.O. PARARET 2 A108 3 2 1 i 1 1 I I I 1 22-0" AFF 22'-0"AFF T.O. PARAPET T.O. PARAPET I I I I 14'-0" AFF T.O. MASONRY ?B.0 AFF B.O. AWNING J_ rz 9'-4" AFF T.O. WINDOW 3'-4" AFF T.O. SILL -0'-6" AFF TUNNEL F.F. 12' 8" AFF B.O. AWNING 8'-0" AFF M.O. SCONCE BRICK; TO MATCH EXTERIOR SILL CAP; TO MATCH EXTERIOR 3-4'AFF T.O. SILL STONE; TO MATCH EXTERIOR _ . 0,-01, F.F.E. ,INTERIOR GARAGE TUNNEL F.F. ■ LEGEND EEF-I: EIFS EXTERIOR FINISH, SAND PEBBLE FINISH AND SMOOTH TRIM BANDS COLOR: MATCH SHERWIN WILLIAMS SW7001 MARSHMALLOW EBR-1: THIN BRICK VENEER, WHITE GENERAL SHALE BRADFORD HALL OR EQUAL ElSTN-I: HORIZON STONE, MANUFACTURED VENEER MASONRY COLOR: SMOKY MOUNTAIN HANDCRAFTED ElSTN-I: HORIZON STONE WATER TABLE SHAPE LEDGESTONE COLOR: SMOKY MOUNTAIN HANDCRAFTED IflMTL-1: PREFINISHED ALUMINUM COPING COLOR: BONE WHITE MTL-2: PREFINISHED ALUMINUM FLAT CANOPIES COLOR: BURNISHED SLATE IflMTL-3: PREFINISHED ALUMINUM SHADE AWNINGS, PAC CLAD 7.2 PANELS ATTACHED TO ALUM FRAME, COLOR: BURNISHED SLATE IflALUM/GLASS: PREFINISHED ALUMINUM DOORS AND WINDOWS COLOR: DARK BRONZE ANODIZED, GLASS COLOR GRAY HOLLOW MTL PAINTED: METAL DOORS AND FRAMES COLOR: SHERWIN WILLIAMS SW6006 BLACK BEAN 10 CLOPAY METAL/GLASS OVERHEAD DOOR SERIES, MODEL 902/903 ALUM COLOR: DARK BRONZE; GLASS COLOR GRAY 11 COILING OVERHEAD DOOR ALUM COLOR: DARK BRONZE 12 LIGHT FIXTURE H COLOR: DARK BRONZE 13 ALUM SCUPPERS AND DOWNSPOUTS H COLOR: DARK BRONZE THOMAS E. MORGAN, JR. ARCHPTECT 423 FISCHER TRAIL ELLIJAY, GEORGIA 30540 DESIGN GR©UP 3450 Acworth Due West Road Building 100, Suite 120 Kennesaw, Georgia 30144 P.770-917-9172 F.770-917-9470 www.mrpdesign.com ENTRANCE END` 0M ELEVATTON A105 SCALE: 3/16" = 1'-0" ISSUES/REVISIONS 1 DATE DESCRIPTION 01 .27.21 REVIEW SET A 107 02.15.21 PERMIT SET 04.18.22 Rwision # I I I 1 1 I i I A106 A108 I I I I I I I 26'-0" AFF T.O. TOWER I I I I I I I I I I DRAWN BY: 4B I 1 I I 1 i 1 CHK'D BY: TM I PROJECT TITLE: I 1 1 I I I I I J n _ n n n- -rrr= • r�� ��r� .gnu.INDOW .SCONCE • __ anew_ ___r= z---z _tee w�sadee es- -arr. = __ zv • _rl4Me�14i_Ym ��_Ym�_r_m�_Y � _ _ iro ��r air_ mom• •m�i �r.�u�r��oa •��o�.�ri � I•. i1 ®- ®--131i— ® -® 0 -C ® pJO--®- i— ® -RI Pik .��a ae. � _ � _tea tea. �>•. _�o • • •' m, �el� .e®• e��e®. a �� �e®� ® I ® ® tee® ® Leo 1•��m 0O�m0i i - lO�l - pq�m00 �mOd�m6-CI�mOC s00 �m00 s 0� v00� O�mOi ��OO �i� �117 WINm00 n,���sil•����I•..��I•��..6i��������G�l•��G���i.��r, 1�1•������i 00!•�������. .����1•. G�1•��,�I I�����u�rfo��l Oo���r i����� ii��l•����I•i i�����1•���1 ,I L0R#1 approved for ARB MMM 4/27/22 SHEET TITLE: SOUTH AND EAST EXTERIOR ELEVATIONS PROJECT NO: 19066 SHEET NUMBER: A105 a- i A B C D E F $ ❑El EJ-A WP�WP ON ROOF CU-1 0 ON ROOF L_ EF-6 INDOOR VAC SPACE 101 3® 1vo�����mseemmil WOMAN'S RESTROO1r2 103 UH-3 ACT rRi/ 2a MECHANICAL EQUIPMENT CONNECTION SCHEDULE WIRE AND COND. ITEM CIRCUIT DESIGNATION VOLT PH LOAD THWN COPPER DISCONNECTING MEANS NOTES AHU-1 THRU CU-1 120 1 1.0 MCA 2#12,1#12(G),1/2"C. 30/1/1/NF 1,4 CU-1 L-28,30 208 1 13.0 MCA 2#12,1#12(G),1/2"C. 30/2/3R/F15A 1,4 EF-1 L-12 120 1 0.1 KW 2#12,1#1 (G), 2"C. RS 1,3 EF-2 L-12 120 1 0.1 KW 2#12,1#12(G),1/2"C. MRS 1,3 EF-3 L-6 120 1 0.1 KW 2#12,1#12(G),1/2"C. MRS 1 EF-4 L-6 120 1 0.1 KW 2#12,1#12(G),1/2"C. MRS 1 EF-5 L-10 120 1 1/8 HP 2#12,1#12(G),1/2"C. 30/1/1/NF 1 EF-6 L-12 120 1 0.14 KW 2#12,1#12(G),1/2"C. MRS 1,3 IRH-2 L-14 120 1 2.6 FLA 2#12,1#12(G),1/2"C. 30/1/4X/NF 1 DJA H-2,4,6 480 3 1-1/2 HP 3#12,1#12(G),1/2"C. 30/3/4X/NF 1,3 DJ-2 H-8,10,12 480 3 1-1/2 HP 3#12,1#12(G),1/2"C. 30/3/4X/NF 1,3 UH-2 L-2,4 208 1 4 KW 2#10,1#10(G),3/4"C. 30/2/1/NF 1 UH-3 L-57,59 208 1 4 KW 2#10,1#10(G),3/4"C. 30/2/1/NF 1 WHA L-26 120 1 2 FLA 2#12,1#12(G),1/2"C. MRS 1 NOTES 1. PROVIDE OVERCURRENT PROTECTION AND BRANCH CIRCUITS PER UL LISTED REQUIREMENTS FOR EQUIPMENT SERVED. REFER TO MANUFACTURER DATAAND EQUIPMENT CUT -SHEETS FOR ROUGHIN LOCATIONS OF ELECTRICAL CONNECTIONS AND INTERCONNECTIONS FOR ALL EQUIPMENT. COORDINATE EXACT NAMEPLATE DATA OF EQUIPMENT BEING INSTALLED WITH MECHANICAL CONTRACTOR.THIS MEANS FOR THE ELECTRICAL CONTRACTOR TO MEET WITH THE MECHANICAL CONTRACTOR AND ACQUIRE A COPY OF THE SHOP DRAWINGS FOR THE EXACT PIECES OF EQUIPMENT THAT WILL BE INSTALLED. THE ELECTRICAL CONTRACTOR SHALL COMPARE THE MANUFACTURER'S DATA SHEETS FOR THE ACTUAL EQUIPMENT THAT IS BEING USED WITH THE ELECTRICAL PLANS PRIOR TO ORDERING THE ELECTRICAL GEAR. IF THERE ARE ANY DIFFERENCES BETWEEN WHAT THE MECHANICAL CONTRACTOR IS PLANNING TO USE AND WHAT THE ELECTRICAL PLANS INDICATE, THE ELECTRICAL CONTRACTOR SHALL BRING THE DISCREPANCIES TO THE ATTENTION OF THE GENERAL CONTRACTOR AND THE CONTRACTORS SHALL WORK OUT ANY ADDITIONAL MONIES REQUIRED WITHOUT ANY COST TO THE OWNER. IF THIS ON SITE COORDINATE DOES NOT HAPPEN, IT WILL BE ASSUMED THAT THE ELECTRICAL CONTRACTOR SHALL ABSORB ANY AND ALL COSTS THAT MAY BE ASSOCIATED WITH THE MECHANICAL CONTRACTOR'S EQUIPMENT. NOTE THAT THE MECHANICAL CONTRACTOR MAY USE DIFFERENT MANUFACTURERS THAN THE DESIGN INTENT PLANS INDICATE AND THESE DIFFERENT MANUFACTURERS MAY HAVE DIFFERENT ELECTRICAL REQUIREMENTS. 2. NOT USED. 3. EXTEND AND CONNECT EXHAUST FAN TO LOCAL LIGHTING CIRCUIT WITHIN THIS ROOM. FAN SHALL BE CONTROLLED BY LOCAL LIGHT SWITCH AND SWITCHED WITH THE LIGHTS. PROVIDE MAGNETIC STARTER FOR CONTROL INTERFACE. 4. INDOOR UNIT POWERED FROM OUTDOOR UNIT. PROVIDE WITH MRS ON INDOOR UNIT IN ORDER TO COMPLY WITH CODE. L-3 PANEL L--L J � L/ L- 4 PANEL H 32 TRANSFORMER'TL' rL-55 (WALL MOUNTED) O ® EF-4 106 V I I r 22-E WP 27-B 2Q 0 2-A 1-DJ) 1-E p ® p 1-X 1-P p 1-H p 1-D L-36 5 (2)L-6 ELECTRICAL AND EQUIPMENT ROOM 105 L-1 ') m� 25-A p 25-D p 25-B Q 25-E Q 25-C p 25-F p IRH-2 F ®�® 1 025-1 ® Q 25-J p 25-K DJ-1 �l L 10-A p 10-A p Hog p 2-A 18-B p 27-C 18-B p p 4 ARCHITECT OF RECORD: THOMAS E. MORGAN, JR. ARCHITECT 423 FISCHER TRAIL ELLIJAY, GEORGIA 30540 TT W. LINDELOW Lie. No. 031170 mmm DESIGN GROUP p 3450 Acworth Due West Road Building 100, Suite 120 130-Cl Kennesaw, Georgia 30144 P.770-917-9172 F.770-917-9470 www.mrpdesign.com ISSUES/REVISIONS ELECTRICAL - POWER PLAN X LEGEND NOTES:O 08A820CDOLLOREDELLEVATION55U6M„rAL 101 SCALE: 3/16" = 1'-0" 1. COORDINATE EXACT REQUIREMENTS AND LOCATIONS WITH OWNER PRIOR TO 04/20/22 REVisioN 1 ROUGH -IN. 2. PROVIDE CONCRETE HOUSEKEEPING PAD UNDER THE MOTOR CONTROL CARWASH EQUIPMENT GENERAL NOTES: CENTER. 1. COORDINATE ALL CARWASH EQUIPMENT LOCATIONS, LOAD, VOLTAGES, 3. PROVIDE WALL MOUNT BRACKETS FOR THE TRANSFORMER. ETC. WITH THE CARWASH EQUIPMENT INSTALLER PRIOR TO ROUGHING IN ANY ELECTRICAL CIRCUITS TO THE EQUIPMENT. 4. PROVIDE POWER CONNECTION FOR THE GAS WATER HEATER CONTROL PANEL. 2. THIS PLAN ONLY INDICATES LINE VOLTAGE CIRCUITS. 5. MOTORIZED DAMPER. INTERLOCK WITH EXHAUST FAN. REFER TO MECHANICAL PLANS FOR ADDITIONAL INFO. 3. PROVIDE ALL CONTROL CIRCUITS FOR THE CARWASH EQUIPMENT PER THE CARWASH EQUIPMENT PLANS. PROVIDE WIRE, CABLE, AND CONDUIT SIZES 6. PROVIDE CONNECTION FOR OWNER PROVIDED WASHER. VERIFY WASHER DRAWN BY: MTC CHK'D BY: SWL AND TYPES PER THE CARWASH EQUIPMENT PLANS. INSTALL ALL CONTROL REQUIREME S WITH OWNER PRIOR TO ROUGH -IN. CIRCUITS IN SEPARATE CONDUIT FROM LINE VOLTAGE CONDUCTORS. 7. CONDUIT SHALL TRAVEL DOWN FACE OF CMU WALL, UNDER WINDOW TO PROJECT TITLE: 4. PROVIDE CONDUIT UNDER FLOOR SLAB FROM EQUIPMENT ROOM TO LOCATION. COORDINATE SPECIFICS WITH OWNER PRIOR TO INSTALLATION. CARWASH TUNNEL FOR CONTROL WIRING, PNEUMATIC TUBING, HYDRAULIC LINES, ETC. AS SHOWN ON THE CARWASH EQUIPMENT PLANS. 8. J-BOXS FOR VACUUM ROOM. COORDINATE LOCATIONS WITH OWNER PRIOR TO `1 ROUGH -IN. 1 J) INDOOR WET LOCATIONS NOTES: GENERAL NOTES: 1. COORDINATE MECHANICAL EQUIPMENT LOCATIONS AND U) Q ; CARWASH TUNNEL IS AN INDOOR WET LOCATION. USE ONLY THE FOLLOWING WIRING METHODS IN THE AREA. ELECTRICAL EQUIPMENT REQUIREMENTS WITH THE MECHANICAL PLANS AND CONTRACTOR. 3: W 1. CONCEAL ALL CONDUITS WITHIN FINISHED WALLS AND CEILING. EMT CONDUIT MAY BE USED ABOVE CEILINGS AND CONCEALED IN CONCRETE 2. PROVIDE A SEPARATE NEUTRAL CONDUCTOR FOR EACH NEW BRANCH CIRCUIT. J _ BLOCK WALLS. 2. PROVIDE GASKETED COVER PLATES FOR ALL FLUSH MOUNTED OUTLET AND DEVICE BOXES. 3. PROVIDE AN INSULATED GREEN EQUIPMENT GROUND CONDUCTOR IN EACH RACEWAY. U \ v�/) w 3. PROVIDE SCHEDULE 40 PVC CONDUIT WITH PVC BOXES WHERE EXPOSED CONDUIT IS BEING UTILIZED. 4. PRIOR TO ROUGH -IN, FIELD COORDINATE ALL RECEPTACLE AND DATA OUTLET LOCATIONS IN THE OFFICE AREA WITH THE GC AND THE MILLWORK INSTALLER. `^ v ) WN I— 4. PROVIDE SCHEDULE 40 PVC CONDUIT FOR UNDER FLOOR CONDUIT AS REQUIRED BY THE ELECTRICAL SPECIFICATION NOTES, SHEET E001, EXCEPT THAT GALVANIZED RIGID STEEL CONDUIT (GRC) ELBOWS WILL NOT 5. COORDINATE MECHANICAL EQUIPMENT DISCONNECT SWITCH LOCATIONS WITH THE MC PRIOR TO ROUGH -IN. DISCONNECT SWITCH SHALL BE READILY ACCESSIBLE PER ARTICLE 100 OF �1Q�.1 0- X O BE REQUIRED FOR CONDUIT RUNS LESS THAT 150 L.F. AND GRC PENETRATIONS THROUGH FLOOR WILL NOT BE REQUIRED WHERE NOT SUBJECT TO DAMAGE. 5. PROVIDE LIQUID -TIGHT FLEXIBLE STEEL CONDUIT WITH STAINLESS STEEL 6. THE NEC. REFER TO SHEET E202 FOR THE MOTOR CONTROL CENTER SCHEDULE'MCC' AND THE CARWASH EQUIPMENT CONNECTION SCHEDULE. PROVIDE "LOCK -OUT' PADLOCK PROVISIONS FOR S _ V OR NYLON COMPRESSION CONNECTORS WHERE REQUIRED FOR EACH MOTOR CONNECTION THAT DOES NOT HAVE A LOCAL CONNECTION TO MOTORS OR OTHER EQUIPMENT SUBJECT TO VIBRATION. DISCONNECTING MEANS AT THE MOTOR. COORDINATE WITH THE MAKE ALL CONNECTORS WRENCH -TIGHT. CAR WASH EQUIPMENT INSTALLER FOR ALL ELECTRICAL REQUIREMENTS. SHEET TITLE: ELECTRICAL POWER PLAN SAVANT Engineering, LLC 5064 Roswell Road, Suite D-301 Sandy Springs GA 30342 770.319.7400 Project20147 02020 'FRTIFTCATF OF ATTTHORUATrnN JinnfR17 PROJECT NO: 19066 E101 ARCHITECT OF RECORD: ELECTRICAL - LIGHTING PLAN SCALE: 3/16" = V-0" LIGHTING CONTROL SCHEDULE DESIG. CIRCUITS CONTROLLED TYPE POLES SCHEDULE CC1 H-7,9 EOMH 4 TIMECLOCK ON/TIMECLOCK OFF CC2 H-1,3,5 EOMH 6 PHOTOCELL ON/TIMECLOCK OFF NOTES: GENERAL NOTES: 1. COORDINATE LIGHT FIXTURE LOCATIONS WITH THE ARCHITECTS REFLECTED CEILING PLAN. 2. WHERE BRANCH CIRCUIT HOMERUNS INDICATE WIRE SIZES, USE THAT WIRE SIZE THROUGHOUT THE BRANCH CIRCUIT, INCLUDING SWITCH LEGS. 3. PROVIDE A SEPARATE NEUTRAL FOR EACH NEW BRANCH CIRCUIT. MULTI -WIRE BRANCH CIRCUITS WILL NOT BE ALLOWED. 4. PROVIDE AN INSULATED GREEN EQUIPMENT GROUND CONDUCTOR IN EACH RACEWAY. LEGEND NOTES:(D 1. TO LIGHTING FIXTURES AT PAY CANOPIES. SEE SHEET E100 FOR MORE DETAILS. 2. LIGHTING CONTROLS TO PROVIDE DUAL LEVEL ILLUMINATION ARE NOT REQUIRED WHEN LIGHTING FOR THE SPACE CONSUMES LESS THAN 0.6 W/SF, PER 2015 IECC 405.2.2.1 EXCEPTION 2.2. THOMAS E. MORGAN, JR. ARCHITECT 423 FISCHER TRAIL ELLIJAY. GEORGIA 30540 TT W. LINDELOW Lie. No. 035170 mmm DESIGN GROUP 3450 Acworth Due West Road Building 100, Suite 120 Kennesaw, Georgia 30144 P.770-917-9172 F.770-917-9470 www.mrpdesign.com ISSUES/REVISIONS DATE I DESCRIPTION 78. 18.201 COLORED ELEVATION5 5U6MITTAL DRAWN BY: MTC CHKD BY: SWL PROJECT TITLE: 5. PROVIDE BLOCKING IN CEILING AS REQUIRED FOR SURFACE MOUNTED FIXTURE SUPPORTS. DO NOT USE SHEETROCK OR OTHER CEILING SYSTEMS AS THE ONLY MEANS OF FIXTURE _ SUPPORT. ' 6. VERIFY THE COLOR OF THE DEVICES AND COVER PLATES FOR ` < > THE LIGHTING CONTROL SYSTEM WITH THE ARCHITECT. _ W N� INDOOR WET LOCATIONS NOTES: J Q CARWASH TUNNEL IS AN INDOOR WET LOCATION. USE ONLY THE FOLLOWING / 1 > WIRING METHODS IN THE AREA. U) 1. CONCEAL ALL CONDUITS WITHIN FINISHED WALLS AND CEILING. EMT CONDUIT MAY BE USED ABOVE CEILINGS AND CONCEALED IN CONCRETE '�^^J V� /J v) W (— BLOCK WALLS. 2. PROVIDE GASKETED COVER PLATES FOR ALL FLUSH MOUNTED OUTLET AND mow/ L^ f. O DEVICE BOXES. L.L J X ()� 3. PROVIDE SCHEDULE 40 PVC CONDUIT WITH PVC BOXES WHERE EXPOSED CONDUIT IS BEING UTILIZED. W Q 4. PROVIDE SCHEDULE 40 PVC CONDUIT FOR UNDER FLOOR CONDUIT AS �l 2 REQUIRED BY THE ELECTRICAL SPECIFICATION NOTES, SHEET E001, v EXCEPT THAT GALVANIZED RIGID STEEL CONDUIT (GRC) ELBOWS WILL NOT BE REQUIRED FOR CONDUIT RUNS LESS THAT 150 L.F. AND GRC PENETRATIONS THROUGH FLOOR WILL NOT BE REQUIRED WHERE NOT SUBJECT TO DAMAGE. 5. PROVIDE LIQUID -TIGHT FLEXIBLE STEEL CONDUIT WITH STAINLESS STEEL OR NYLON COMPRESSION CONNECTORS WHERE REQUIRED FOR CONNECTION TO MOTORS OR OTHER EQUIPMENT SUBJECT TO VIBRATION. MAKE ALL CONNECTORS WRENCH -TIGHT. SAVANT Engineering, . SHEET TITLE: ELECTRICAL LIGHTING PLAN PROJECT NO: 19066 E102 5064 Roswell Road, Suite D-301 ty Springs GA 30342 770.319.7400 Proiect20147 02020 ARCHITECT OF RECORD: EQUIPMENT LIST RESPONSIBILITY MATRIX ITEM # DESCRIPTION VOLT HP 0 AMP GCB MS ELECTRICAL WORK PANEL/CIRCUIT WIRE SIZE FURN. BY: ERECTED BY: WIRED BY: CWC-SYS CARWASH CONTROL SYSTEMS 120 1 20 SONNY'S GC GC L-2 2912, 1912(G), 12"C. 1-A RECLAIM PUMP STATION 480 5HP 3 7SA 15 SONNY'S SCWI GC H-14,16,18 (CONTROL: L-24) 3912, 1912(G), 314"C. 1-D (R.O.) FILTRATION SYSTEM 480 2HP 3 3.4A 15 SONNY'S SCWI GC H-20,22,24 (CONTROL: L-38) 3#12, 1#12(G), 3/4"C. 1-E (R.O.) REPRESSURIZER 480 2HP 3 3.4A 15 SONNY'S SCWI GC H-26,28,30 (CONTROL: L-38) 3912, 1#12(G), 3/4"C. 1-H WATER PRESSURIZATION PUMP 480 5HP 3 7.6A 15 SONNY'S SCWI GC H-32,34,36 3#12, 1#12(G), 3/4"C. 1-P WATER SOFTENER SYSTEM (25CF) 120 1 0.6A 16 SONNY'S scm GC H-32,34,36 3#12, 1#12(G), 3/4"C. 1-X R.O. REJECT PUMP 480 5HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S GC MCG7 NOTE 1 2-A PREP GUN UNIT 480 7.SHP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S GC MCG-2 NOTE 1 2-A PREP GUN UNIT 480 T5HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S GC MCC-3 NOTE 1 10-A AIR COMPRESSOR 480 tOHP 3 14A 25 BY OTHERS ENIA GC H-27,29,31 3#10, 1#10(G), 3/4"C. 1&A AIR COMPRESSOR 480 tOHP 3 14A 25 BY OTHERS GC H-33,35,37 3#10,1#10(G),314"C10-L AIR DRYER 50.CFM (COMPRESSOR 15) 120 114HP 1 SAA 15 BY OTHERS GC L-16 2#12, 1#12(G), 12"C. 11-B WRAP BRUSH POWER PACK 480 7.SHP 3 NOTE1 NOTE1 NOTEI SONNY'S GC MCC4 NOTE 11-BB WRAP BRUSH POWER PACK 480 7.SHP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCGS NOTE 1 11-1 TGB_FPS POWER PACK 480 7.5HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCG-6 NOTE 1 12-A OMNI POWER UNIT 480 5HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCG7 NOTE 1 13-C H-26 OMNI PUMP TOP (91) 480 15HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCG-8 NOTE 1 13-F H-25 OMNI PUMP SIDE (#1) 480 15HP 3 NOTE 1 NOTE 1 NOTE i SONNY'S SCWI GC MCG-9 NOTE 1 13-M H-25 PENDULUM PUMP 480 15HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCC-10 NOTE 1 i&B CONVEYOR POWER UNIT 480 10HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCC-11 NOTE 1 1&B CONVEYOR POWER UNIT 480 10HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCCA2 NOTE 1 20-B PROGRAMMER PUSHBUTTON STATION 120 1 20 SONNY'S GC L-25 2#12, 1#12(G), 12"C. 20-C PAY STATION (3) 120 1 20 SONNY'S SCWI GC L-13,15,17 (3) 2#12, 1#12(G), 12"C. 20-D GATE (3) 120 1 20 SONNY'S SCWI GC L49,51,53 (3) 2#12, 1#12(G), 12"C. 20-1 LICENSE PLATE RECOGNITION (3) 120 1 20 SONNY'S SCWI GC L-50,52,54 (3) 2#12, 1#12(G), 1/2"C. 21 MOTOR CONTROL CENTER (MCC) 480 3 SONNY'S Sew] GC SEE "MCC" SCHEDULE SEE RISER DIAGRAM 22-E WARNING HORN 120 1 SONNY'S SCWI GC L-27 2#12, 1#12(G), 1/2"C. 234 MITTER/MOTOR SFM901 (FB) 480 2HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCC-13 NOTE 1 24-G TOP BRUSH MOTOR 480 1HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCCA4 NOTE 1 2" TOP BRUSHIMOTOR BnD 480 1HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCC-15 NOTE 1 2&A BLOWER MOTOR NO. 1 480 15HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCCA6 NOTE 1 2&13 BLOWER MOTOR NO.2 480 15HP 3 NOTE 1 NOTE 1 NOTE i SONNY'S SCWI GC MCC-17 NOTE 1 25-C BLOWER MOTOR NO. 3 480 15HP 1 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S Sew] GC MCC-18 NOTE 1 25S1) BLOWER MOTOR NO.4 480 15HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCCA9 NOTE 1 2&E BLOWER MOTOR NO. 6 480 15HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCG20 NOTE 1 2&1` BLOWER MOTOR NO.6 480 15HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCC-21 NOTE 1 25-G BLOWER MOTOR NO. 7 480 15HP 3 INOTE1 NOTE 1 I NOTE 1 I SONNY'S SCWI GC MCG22 NOTE 1 25-H BLOWER MOTOR NO. 8 480 15HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCC-23 NOTE 1 254 BLOWER MOTOR NO. 9 480 15HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCC-24 NOTE 1 2W BLOWER MOTOR NO. 10 480 15HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S Sew] GC MCG-26 NOTE 1 25-K BLOWER MOTOR NO. 11 480 15HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCG-26 NOTE 1 2&L BLOWER MOTOR NO. 12 480 15HP 3 NOTE 1 NOTE 1 NOTE 1 SONNY'S SCWI GC MCG27 NOTE 1 27-B U. SOUND SENSOR CONTROL BOX 120 1 0.26A 20 SONNY'S SCWI GC L-7 2912, 1#12(G), 12"C. 27-C CONVEYER PULSE CONTROL BOX 120 1 0.25A 20 SONNY'S SCWI GC L-7 2#12, 1#12(G), 12"C. 29-3 PIPE LIGHT, LED IP69K (SIGN) 120 1 1 0.57A 20 SONNY'S SCWI GC L-7 2#12, 1#12(G), 12"C. 30-C (WAIT& GO) INSTRUCTIONAL SIGN 120 1 2.5A 20 SONNY'S SCWI GC L-39 2#12, 1#12(G), 12"C. 30.E ENTRANCE INSTRUCTIONAL CABINET 120 1 20 SONNY'S Sew] GC L-11 2#12, 1#12(G), 12"C. 30-G PKG. RECEIVED SIGN 120 1 20 SONNY'S SCWI GC L-29 2#12, 1#12(G), 12"C. 304 MENU 6'HX3W 120 1 20 SONNY'S SCWI GC L49,21,23 (3) 2#12, 1#12(G), 1/2"C. 33-D BOOSTER PUMP 480 7.SHP 3 11A 20 1 SONNY'S SCWI GC MCG-28 5912, 1#12(G), 3/4"C. NOT USED 37-K VACUUM (30HP) 480 30HP 3 40A 80 3 SONNY'S SCWI GC MCG-30 3#8, 1#8(G), 1"C. 37-K VACUUM (3OHP) 480 30HP 3 40A 80 3 SONNY'S SCWI GC MCG-31 3#8, 1#8(G), VC. 37-K VACUUM (30HP) 480 30HP 3 40A 80 3 SONNY'S SCWI GC MCC-32 3fF8, 1#8(G), 1"C. 38 MAT. MACHINE 120 1 20 SONNY'S SCWI GC L-32 2#12, 1#12(G), 12"C. NOTES: SEE MCC SCHEDULE. SCWI = SONNY'S (CAR WASH INSTALLER) GC = GENERAL CONTRACTOR NOTE: VERIFY ALL REQUIREMENTS WITH CARWASH INSTALLER PRIOR TO ROUGH -IN. MOTOR CONTROL PANEL: MCC TYPE: UL508 INDUSTRIAL CONTROL PANEL SEE NOTES 1 & 3 SERVICE: 480V/30/3W I MAIN: 600A MAIN LUGS CKT # SONNY'S EQUIP # (NOTE 2) EQUIPMENT SERVED (NOTE 5) HP FLA CKT BKR SIZE STARTER SIZE MINIMUM WIRE & CONDUIT (SEE NOTE 4) 1 1-X R.O. REJECT PUMP 5 7.6 1513 N/A 3#12, 1#12(G), 3/4"C. 2 2-A PREP GUN UNIT 7.5 11.0 20/3 1 3#12, 1#12(G), 3/4"C. 3 2-A PREP GUN UNIT 7.5 11.0 20/3 1 3#12, 1#12(G), 3/4"C. 4 11-B WRAP BRUSH POWER PACK 7.5 11.0 20/3 1 5#12, 1#12(G), 3/4"C. 5 11-BB WRAP BRUSH POWER PACK 7.5 11.0 20/3 1 5#12, 1#12(G), 3/4"C. 6 11-1 TGB_SFB POWER PACK 7.5 11.0 20/3 1 5#12, 1#12(G), 3/4"C. 7 12-A OMNI POWER UNIT 5 7.6 15/3 0 5#12, 1#12(G), 3/4"C. 8 13-C H-25 OMNI TOP PUMP 15 21.0 40/3 2 (VFD) 3#8, 1#8(G), 1"C. 9 13-F H-25 OMNI SIDE PUMP 15 21.0 40/3 2 (VFD) 3#8, 1#8(G), 1"C. 10 13-M H-25 PENDULUM PUMP 15 21.0 40/3 2 (VFD) 3#8, 1#8(G), 1"C. 11 18-B CONVEYOR POWER PACK 10 14.0 30/3 1 5#10, 1#10(G), 3/4"C. 12 18-B CONVEYOR POWER PACK 10 14.0 30/3 1 5#10, 1#10(G), 3/4"C. 13 23-4 MITER MOTOR (FB) 2 3.4 15/3 00 (VFD) 3#12, 1#12(G), 3/4"C. 14 24-G TOP BRUSH MOTOR 1 2.1 15/3 00 (VFD) 3#12, 1#12(G), 3/4"C. 15 25-8 TOP BRUSH/MOTOR BnD 1 2.1 15/3 00 3#12, 1#12(G), 3/4"C. 16 25-A BLOWER MOTOR NO. 1 15 21.0 40/3 2 3#8, 1#8(G), 1"C. 17 25-B BLOWER MOTOR NO. 2 15 21.0 40/3 2 3#8, 1#8(G), 1"C. 18 25-C BLOWER MOTOR NO. 3 15 21.0 40/3 2 3#8, 1#8(G), 1"C. 19 25-D BLOWER MOTOR NO. 4 15 21.0 40/3 2 3#8, 1#8(G), 1"C. 20 25-E BLOWER MOTOR NO. 5 15 21.0 40/3 2 3#8, 1#8(G), 1"C. 21 25-F BLOWER MOTOR NO. 6 15 21.0 40/3 2 3#8, 1#8(G), 1"C. 22 25-G BLOWER MOTOR NO. 7 15 21.0 40/3 2 3#8, 1#8(G), 1"C. 23 25-H BLOWER MOTOR NO. 8 15 21.0 40/3 2 3#8, 1#8(G), 1"C. 24 25-1 BLOWER MOTOR NO. 9 15 21.0 40/3 2 3#8, 1#8(G), 1"C. 25 25-J BLOWER MOTOR NO. 10 15 21.0 40/3 2 3#8, 1#8(G), 1"C. 26 25-K BLOWER MOTOR NO. 11 15 21.0 4013 2 3#8, 1#8(G), 1"C. 27 25-L BLOWER MOTOR NO. 12 15 21.0 40/3 2 3#8, 1#8(G), 1"C. 28 33-D BOOSTER PUMP 7.5 11.0 20/3 N-A 5#12, 1#12(G), 3/4'C. 29 SPARE 30 37-K VACUUM 30 40.0 80/3 3 3#8, 1#8(G), 1"C. 31 37-K VACUUM 30 40.0 80/3 3 3#8, 1#8(G), 1"C. 32 37-K VACUUM 30 40.0 80/3 3 3#8, 1#8(G), 1"C. ALL TERMINATIONS SHALL BE SUITABLE FOR 75°C COPPER OR ALUMINUM TOTAL CONN. AMPS 585.8 FURNISHED WITH INTERIOR MAINTENANCE LIGHT (SEE NOTE 6) TOTAL VOLT AMPS 486,780 NOTES: 1. CONTROL PANEL IS FURNISHED WITH WASH TUNNEL EQUIPMENT (BY SONNY'S ENTERPRISES, INC.). EC TO COORDINATE EXACT LOCATIONS OF INDICATED EQUIPMENT, MAKE FINAL CONNECTIONS, AND WIRE COMPLETE. 2. ALPHA -NUMERIC DESIGNATIONS IN THIS COLUMN CORRESPOND TO CARWASH EQUIPMENT PROVIDED BY CARWASH MANUFACTURER. SEE SONNY'S CARWASH PLANS (CWP) FOR LOCATIONS. 3. INFORMATION SHOWN ON THIS SCHEDULE SHOWS MINIMUM POWER WIRING REQUIREMENTS FOR LOADS SERVED BY THIS UL 508 1 INDUSTRIAL CONTROL PANEL. CONTRACTOR SHALL REFERENCE SONNY'S CARWASH PLANS (CWP) FOR PRECISE LOAD LOCATIONS, CONTROL WIRING, & RACEWAY REQUIREMENTS. DESIGN OF 24 VAC CONTROLS ARE NOT A PART OF THIS DESIGN BUT SHALL BE INCLUDED IN CONTRACTOR'S SCOPE OF WORK. SEE SONNY'S CARWASH PLANS (CWP), ATTACHED TO THIS SET, FOR OTHER WIRING AND RACEWAY REQUIREMENTS. 24 VAC CONTROL WIRING & RACEWAYS SHALL BE INSTALLED BY CONTRACTOR PER CWP PLANS. 1 4. FEEDERS INDICATED IN THIS SCHEDULE ARE SUFFICIENT FOR THE SCHEDULED LOADS INDICATED. HOWEVER, IN SOME CASES, THE EQUIPMENT MANUFACTURER MAY INDICATE AN ENHANCED INSTALLATION (SHOWING LARGER WIRE AND/OR RACEWAYS). EC SHALL COORDINATE FINAL LAYOUT AND, WHERE FEASIBLE AND OTHERWISE ALLOWED BY THE NATIONAL ELECTRICAL CODE, CONTRACTOR MAY INSTALL THE LARGER CONDUCTORS AND/OR RACEWAYS INDICATED ON THE SONNY'S DOCUMENTS. 5. SAFETY DISCONNECTS SHALL BE PROVIDED ADJACENT TO ALL EQUIPMENT THAT IS >50'-0" OR NOT IN THE LINE OF SIGHT OF THE MCC. 6. PROVIDE A 120-VOLT CIRCUIT TO POWER INTERIOR MAINTENANCE LIGHT (I.E. LIGHT IS OPERABLE WHEN PANEL IS DE -ENERGIZED FOR t MAINTENANCE). SCHEDULE OF PANEL H CKT. NO. TRIP L DESCRIPTION LTS REC HTG A/C MTR MISC A B C I MISC MTR A/C HTG REC LTS DESCRIPTION TRIP CKT. NO. 1 20/1 SIGN LIGHTING 1.2 40 0.8 DOOR JET HEATER (DJ-1) 15 2 3 20/1 CANOPY & POLE LIGHTING 1.1 0.8 DOOR JET HEATER (DJ-1) 4 5 20/1 SECURITY/SITE LTG 0.3 0.8 DOOR JET HEATER (DJ-1) 3 6 7 20/1 OFFICE/EQUIP RM LTG 0.9 40 0.8 DOOR JET HEATER (DJ-2) 15 8 9 20/1 WASH TUNNEL LTG 1.0 0.8 DOOR JET HEATER (DJ-2) 10 11 20/1 SPARE 0.0 0.8 DOOR JET HEATER (DJ-2) 3 12 13 20/1 SPARE 0.0 40 2.1 RECLAIM P.S. (1-A) 15 14 15 — SPACE 2.1 RECLAIM P.S. (1-A) 16 17 — SPACE 2.1 RECLAIM P.S. (1-A) 3 18 19 — SPACE 40 0.9 R.O. FILT. PUMP (1-D) 20 21 SPACE 0.9 R.O. FILT. PUMP (1-D) ;13 22 23 SPACE 0.9 R.O. FILT. PUMP (1-D) 24 25 25 AIR COMPRESSOR (10-A) 3.9 0.9 R.O. PRESS. PUMP (1-E) 15 26 27 AIR COMPRESSOR (10-A) 3.9 0.9 R.O. PRESS. PUMP (1-E) 28 29 3 AIR COMPRESSOR (10-A) 3.9 0.9 R.O. PRESS. PUMP (1-E) 3 30 31 25 AIR COMPRESSOR (10-A) 3.9 40 2.1 WATER PRESS. PUMP (1-H) 15 32 33 AIR COMPRESSOR (10-A) 3.9 40 2.1 WATER PRESS. PUMP (1-H) 34 35 3 AIR COMPRESSOR (10-A) 3.9 40 2.1 WATER PRESS. PUMP (1-H) 3 36 37 600 MOTOR CONTROL PANEL 162.3 0.0 S.O. 15 38 39 MOTOR CONTROL PANEL 162.3 0.0 S.O. 40 41 3 MOTOR CONTROL PANEL 162.3 0.0 S.O. 3 42 43 — SPACE 2.4 0.3 0.9 0.4 2.6 0.4 PANEL L 50 44 45 — SPACE 2.4 0.3 0.9 0.4 2.6 0.4 PANEL L 46 47 j — j SPACE 2.4 0.3 0.9 0.4 2.6 0.4 PANEL L 31 48 CATEGORY TOTALS CONNECTED (KVA) 4.5 510.3 7.2 18.9 2.7 6.0 7.8 1.2 CATEGORY TOTALS CONNECTED (KVA) 800A MCB MAIN RATING 1 277/480 VAC 3 PHASE 4 WIRE PROVIDE FEED-THRU LUGS: NO TOTAL CONNECTED LOAD: 558.4 MINIMUM BREAKER AIC: 65,000 1 PROVIDE IG BUS BAR: NO I NEMA RATING: 1 MOUNTING: SURFACE I TOTAL DEMAND LOAD: 593.0 * -DENOTES PROVIDE LOCK -ON CIRCUIT BREAKER + -DENOTES PROVIDE GFCI CIRCUIT BREAKER I # -DENOTES PROVIDE AFCI CIRCUIT BREAKER NOTES: 1. BREAKER TO BE 100% RATED FOR CONTINUOUS DUTY. SCHEDULE OF PANEL L CKT. NO. TRIP DESCRIPTION LTS REC HTG A/C MTR MISC A B C MISC MTR A/C HTG REC LTS DESCRIPTION TRIP CKT. 1 20/1 RCPT- EQUIP ROOM 0.8 40 2.0 UH-2 30 2 3 20/1 RCPT - ELEC ROOM 0.8 2.0 UH-2 2 4 5 20/1 SPARE 40 0.2 7 20/1 TUNNEL (29-3, 27-B,C) 0.3 4 SPARE 20/1 8 9 20/1 SPARE 40 0.7 EXHAUST FAN (EF-5) 20/1 10 11 20/1 ENTRANCE SIGN (30E) 0.2 40 0.2 0.6 BATHROOM LTG/EF-1/2 20/1 12 13 20/1 PAY STATION (20-C) 0.2 40 1 0.5 GAS IR & UNIT HTRS 20/1 14 15 20/1 PAY STATION (20-C) 0.2 0.7 AIR DRYER (10-L) 20/1 16 17 20/1 SPARE 40 0.5 WATER SOFTENER (1-P) 20/1 18 19 20/1 MENU SIGN (30-1) 0.2 40 0.3 NEON SIGNS 20/1 20 21 20/1 MENU SIGN (30-1) 0.2 40 0.3 NEON SIGNS 20/1 22 23 20/1 SPARE 40 0.3 CONTROL (1-A) 20/1 24 25 20/1 INPUT TERMINAL (20-B) 0.2 40 0.5 WATER HEATER (WH-1) 20/1 26 27 20/1 WARNING HORN (22-E) 0.2 40 1.4 CU-1 20 28 29 20/1 PKG RCVD SIGN (30G) 0.2 40 1.4 CU-1 2 30 31 20/1 SPARE 40 1.0 MAT WASH (38) 20/1 32 33 20/1 SPARE 40 1.0 + RCPT - VENDING 20/1 34 35 20/1 SERVER COMPUTER 0.8 40 1.0 + RCPT - VENDING 20/1 36 37 20/1 RECEPTACLES 1.0 40 0.3 CONTROL (1-D,E) 20/1 38 0.3 SPARE 20/1 40 41 20/1 RCPT - OPERATIONS 0.36 1.5 GATE OVERRIDE 20/1 42 43 20/1 RCPT - OFFICE 0.8 40 _45- 0 1.5 VACUUM RM JB 20/1 46 47 20/1 RECEPTACLES 1.08 11111, 1.5 VACUUM RM JB 20/1 48 49 20/1 GATE (20-D) 51 20/1 GATE (20-D) LICENSE (20-I) 20/1 52 53 20/1 SPARE LICENSE (20-1) 20/1 54 5 20/1 WASHER 0. SPACE 56 57 UH-3 2.0 4NE SPACE 58 59 �/2 U H - 3 2.0 P C 6 CATEGORY TOTALS CONNECTED (KVA) 5.8 4.0 1.1 2.8 4.5 2.0 1.2 CATEGORY TOTALS CONNECTED (KVA) 100A MCB MAIN RATING 120/208 V C 3 PHASEFEED-THRU LUGS: NO TOTAL CONNECTED LOAD: 33.2 MINIMUM BREAKER AIC: 42,000 PROVI E IG BUS BAR: 1 MOUNTING: RECESSED TOTAL DEMAND LOAD: 33.5 �c -DENOTES PROVIDE LOCK -ON CIRCUIT BREAKER + -DENOTES PROVIDE GFCI CIRCUIT BREAKER -DENOTES PROVIDE AFCI CIRCUIT BREAKER NOTES: SAVANT Engineering, . THOMAS E. MORGAN, JR. ARCHITECT 423 FISCHER TRAIL ELLIJAY. GEORGIA 30540 TT W. LINDELOW Lie. No. 035170 mmm DESIGN GROUP 3450 Acworth Due West Road Building 100, Suite 120 Kennesaw, Georgia 30144 1 P.770-917-9172 F. 77 0-917-9470 www.mrpdesign.com ISSUES/REVISIONS DATE I DESCRIPTION 78. 18.201 COLORED ELEVATION5 SUBMITTAL DRAWN BY: MTC CHK'D BY: PROJECT TITLE: 1 ''__ VJ \ Q N� W U > 1 U�/)w U) LL] 0�0 0- J X ry W Q � U SHEET TITLE: SWL ELECTRICAL PANEL SCHEDULES PROJECT NO: 19066 E202 5064 Roswell Road, Suite D-301 ty Springs GA 30342 770.319.7400 Proiect20147 02020 ARCHITECT OF RECORD: H.V.A.C. LEGEND: ® SUPPLY DIFFUSER RETURN AIR GRILLE ® EXHAUST AIR GRILLE x/x RIGID DUCTWORK (WIDTH/DEPTH) r^ ^S FLEX DUCTWORK (DIAMETER) ELBOW WITH TURNING VANES T MANUAL VOLUME DAMPER MVD MOTORIZED VOLUME DAMPER ED FIRE DAMPER SD DUCT MOUNTED SMOKE DETECTOR OT THERMOSTAT OHUMIDISTAT TS TEMPERATURE SENSOR 1 1 1 H.V.A.C. KEYNOTES OX : 1. ROUTE FULL SIZE CONDENSATE FROM AHU WITH P-TRAP DOWN IN EXTERIOR WALL AND TERMINATE 8" ABOVE FINISHED GRADE WITH TURNED DOWN ELBOW. 2. ROUTE REFRIGERANT LINE FROM AHU TO CONDENSING UNIT. 3. ROUTE INSULATED OUTSIDE AIR DUCT TO EXTERIOR WALL CAP. CAP MINIMUM 10'-0" FROM ANY EXHAUST OR PLUMBING VENTS. PROVIDE MANUAL VOLUME DAMPER TO BALANCE OUTSIDE AIR AS REQUIRED. 4. COMBUSTION AIR FOR UHUH=1 PROVIDED BY UNCONFINED SPACE - APPROX. 10,000 CF. 5. COMBUSTION AIR PROVIDED BY UNCONFINED SPACE - APPROX. 22,000 CF. 6. 24X24 DUCT WITH 120V MOTORIZED DAMPER INTERLOCKED WITH EF-3. SET DAMPER TO OPEN AT OPERATION OF FAN. 7. COORDINATE LOCATION WITH ROLL -UP DOORS. INSTALL 2 FT BELOW PLASTIC LINER ON CEILING PER MANUFACTURER'S 8. COORDINATE AHU LOCATION ABOVE CEILING. THERMOSTAT SHALL BE DESIGNED FOR WET LOCATIONS. 10. ROUTE FLUE VENT TO ROOF. PROVIDE ALL REQUIRED CLEARANCES. INSTALL PER MANUFACTURER'S INSTRUCTIONS. 11. ROUTE GALV. STEEL EXHAUST DUCT TO CAP AT EXTERIOR WALL. 12. 4" DRYER DUCT FROM OWNER PROVIDED DRYER 13. ROUTE GALV. STEEL EXHAUST DUCT TO CAP ON ROOF. MAINTAIN 10'-0" FROM ANY AIR INTAKES. FLOOR PLAN - H.V.A.C. M101 3/10 = P-O" H.V.A.C. GENERAL NOTES: 1. COORDINATE ALL MECHANICAL WORK WITH ALL OTHER TRADES. VERIFY ALL EXISTING CONDITIONS BEFORE THE START OF WORK. 2. TRANSITION ALL SUPPLY AND RETURN DUCTWORK FROM PACKAGED ROOFTOP EQUIPMENT TO DUCT THROUGH ROOF (DTR) SIZE. COORDINATE EXACT LOCATIONS WITH ROOF AND WALL STRUCTURAL SYSTEM. VERIFY ADEQUACY OF STRUCTURE TO SUPPORT MECHANICAL EQUIPMENT WITH ARCHITECT PRIOR TO INSTALLATION. 3. LINE ALL RECTANGULAR AIR CONDITIONING DUCTWORK WITH 1" THICK DUCT LINER PER SPECIFICATIONS. 4. ALL DUCT ELBOWS SHALL BE MITERED WITH SINGLE THICKNESS TURNING VANES UNLESS INSTRUCTED OTHERWISE ON DRAWINGS. PROVIDE 45 DEGREE ENTRY FITTINGS AT BRANCH DUCT CONNECTIONS TO DUCT MAINS. FLEXIBLE DUCTS SHALL BE INSTALLED TO MAINTAIN FULL CROSS -SECTIONAL FREE AREA. PROVIDE RIGID SHEET METAL ELBOWS OR LINED PLENUM BOXES AT AIR DEVICES WHEN REQUIRED. 5. COORDINATE EXACT LOCATION OF ALL AIR DEVICES WITH ARCHITECTURAL REFLECTED CEILING PLAN. 6. ROUTE CONDENSATE WITH MINIMUM SLOPE OF 1/8" PER 1'-0". 7. ROUTE DUCTS FROM TOILET EXHAUST FANS TO ROOF CAPS. CONCEAL DUCTWORK. ROOF CAPS SHALL BE FLASHED WEATHERTIGHT. OFFSET EXHAUST DISCHARGE AS REQUIRED ENSURING A MINIMUM 10'-0" CLEARANCE FROM ALL OUTSIDE AIR INTAKES. 8. ALL LOW VOLTAGE CONTROL WIRING AND ITS INSTALLATION TO BE BY MECHANICAL CONTRACTOR. INSTALL PER ELECTRICAL SPECIFICATIONS. MOUNTING HEIGHT OF THERMOSTATS SHALL BE PER ADA REQUIREMENTS. 9. VERIFY ADEQUACY OF GAS APPLIANCE VENT SIZES BASED ON ACTUAL INSTALLATION (TOTAL VENT HEIGHT AND ANY LATERAL OFFSETS). INSTALLATION SHALL COMPLY WITH ALL CODE REQUIREMENTS. PROVIDE TYPE "B" VENT PIPING AND U.L. LISTED CAP. 10. MECHANICAL CONTRACTOR SHALL REVIEW ALL ELECTRICAL DRAWINGS BEFORE PURCHASING EQUIPMENT TO ENSURE THAT PROPER ELECTRICAL SERVICE IS TO BE PROVIDED FOR ALL NEW EQUIPMENT. 11. CLOTHES WASHER EXHAUST DUCT SHALL BE 4" NOMINAL IN DIAMETER. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 EQUIVALENT FEET FROM THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL. 12. COMPLY WITH THE INTERNATIONAL ENERGY CONSERVATION CODE AS ADOPTED PER SECTION 101.2 AND ANY AMENDMENTS OF THE 2015 VIRGINIA CONSTRUCTION CODE. 13. ALL EQUIPMENT IN WASH TUNNEL SHALL BE APPROVED FOR INSTALLATION IN A WET LOCATION. H.V.A.C. SPECIFICATIONS: 15010 MECHANICAL REQUIREMENTS: DO ALL WORK IN COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND ORDINANCES, THE FLORIDA BUILDING CODE AND THE REGULATIONS OF THE LOCAL UTILITY COMPANIES. OBTAIN AND PAY FOR ANY AND ALL REQUIRED PERMITS, INSPECTIONS, CERTIFICATES OF INSPECTIONS. COOPERATE WITH OTHER TRADES AND CONTRACTORS AT JOB. PERFORM WORK IN SUCH MANNER AND AT SUCH TIMES AS NOT TO DELAY WORK OF OTHER TRADES. OBTAIN MANUFACTURER'S DATA ON ALL EQUIPMENT, THE DIMENSIONS OF WHICH MAY AFFECT INSTALLATION. USE THIS DATA TO COORDINATE PROPER SERVICE CHARACTERISTICS, ENTRY LOCATIONS, ETC., AND TO ENSURE MINIMUM CLEARANCES ARE MAINTAINED. WORKMAN SHALL BE EXPERIENCED IN THEIR RESPECTIVE TRADE. WORKMANSHIP OF INSTALLED WORK SHALL BE FIRST CLASS AND WILL BE SO JUDGED. SUBSTANDARD WORK SHALL BE REMOVED AND REPLACED AT CONTRACTOR'S EXPENSE. CONTRACTOR SHALL AND DOES HEREBY WARRANT ALL MATERIALS AND EQUIPMENT FURNISHED UNDER THIS SECTION TO BE FREE FROM DEFECTS AND TO FUNCTION OR OPERATE SATISFACTORILY FOR ONE YEAR AFTER FINAL ACCEPTANCE OF THE WORK, AND THAT ANY ITEMS NOT MEETING THIS REQUIREMENT WILL BE MADE GOOD BY HIM WITHOUT ANY COST TO THE OWNER. PROVIDE ONLY NEW, STANDARD FIRST -GRADE MATERIALS THROUGHOUT, CONFORMING TO STANDARDS ESTABLISHED BY UNDERWRITER LABORATORIES INC., AND SO MARKED AND LABELED, TOGETHER WITH MANUFACTURER'S BRAND OR TRADEMARK. ALL LIKE ITEMS SHALL BE OF ONE MANUFACTURER. ALL WORK SHALL BE EXECUTED IN A MANNER THAT SHALL PRESENT A NEAT APPEARANCE UPON COMPLETION. CARE SHALL BE EXERCISED THAT ALL ITEMS ARE PLUMB, STRAIGHT AND LEVEL. UPON COMPLETION OF WORK, ALL SYSTEMS SHALL BE TESTED, AND SHALL BE SHOWN TO BE IN PERFECT WORKING CONDITION IN ACCORDANCE WITH THE INTENT OF THE DRAWINGS. ANY WALLS, CEILINGS, EQUIPMENT, ETC., DAMAGED BY THE CONTRACTOR IN CONSTRUCTION OF THIS PROJECT SHALL BE REPAIRED, RESTORED AND/OR REPLACED BY THE CONTRACTOR TO ITS ORIGINAL CONDITION, OR TO PERFORM ITS INTENDED FUNCTION, AT NO ADDITIONAL COST TO OWNER. H.V.A.C. SPECIFICATIONS (CONT. ib1.1.1"7uIuIklIe3 PIPING SHALL BE NEW AND IN GOOD CONDITION. ALL PIPING SHALL CONFORM TO ALL APPLICABLE STATE, COUNTY AND LOCAL CODES. PIPING SHALL BE INSTALLED PARALLEL TO BUILDING LINES PIPING SHALL BE COORDINATED WITH OTHER TRADES PRIOR TO INSTALLATION. OFFSETS AS REQUIRED TO COORDINATE WITH STRUCTURE AND OTHER TRADES SHALL BE MADE AT NO ADDITIONAL COST. PIPING SHALL BE TESTED IN ACCORDANCE WITH INDUSTRY ACCEPTED METHODS. LEAKS SHALL BE REPAIRED AND ANY LOST REFRIGERANT SHALL BE REPLACED AT NO ADDITIONAL COST. DIELECTRIC UNIONS SHALL BE INSTALLED IN ALL COPPER AND FERROUS PIPING CONNECTIONS. 15891 DUCTWORK: ALL DUCTWORK MATERIALS AND INSTALLATION SHALL CONFORM TO APPLICABLE STATE, COUNTY AND LOCAL CODES. DUCTWORK SHALL BE ALL NEW AND IN GOOD CONDITION. DUCT DIMENSIONS NOTED ARE INSIDE DIMENSIONS AND DO NOT INCLUDE INSULATION OR LINER. DUCTWORK SHALL BE INSTALLED TO AVOID CONFLICT WITH OTHER TRADES. ANY OFFSETS REQUIRED SHALL BE INSTALLED AT NO ADDITIONAL COST. FABRICATE DUCTWORK FROM SHEET METAL. DUCT SHALL BE INSULATED WITH DUCT WRAP INSULATION. DUCTWORK SHALL BE INSTALLED IN ACCORDANCE WITH SMACNA LOW PRESSURE DUCTWORK STANDARDS. ibi:kI�il x.�i/_1.I H:L1A_1� [y� CONTRACTOR SHALL BE CERTIFIED BY NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) OR BY ASSOCIATED AIR BALANCE COUNCIL (AABC). TEST AND BALANCE ALL AIR SYSTEMS IN ACCORDANCE WITH AABC AND/OR NEBB REQUIREMENTS. ALL EQUIPMENT USED FOR TESTING SHALL BE IN PROPER WORKING ORDER. THE CONTRACTOR SHALL REGULATE AND ADJUST ALL SPUTTERS, DEFLECTORS AND DAMPERS SO THAT THE INLET OR OUTLET SHALL DELIVER OR REMOVE THE REQUIRED NUMBER OF CUBIC FEET OF AIR PER MINUTE (CFM) AT THE RESPECTIVE OPENINGS. ALL TESTS SHALL BE CONDUCTED IN THE PRESENCE OF THE CONSTRUCTION SUPERINTENDENT, OR HIS REPRESENTATIVE. THE CONTRACTOR SHALL FURNISH ALL INSTRUMENTS, TESTING EQUIPMENT AND PERSONNEL THAT MAY BE REQUIRED FOR THE TESTS. PROVIDE VIBRATION ISOLATORS AND ACOUSTIC INSULATION AS REQUIRED TO ELIMINATE ANY OBJECTIONABLE NOISE OR VIBRATION. SAVANT Engineering, LLC 5064 Roswell Road, Suite D-301 Sandy Springs GA 30342 770.319.7400 Project 20147 02020 THOMAS E. MORGAN, JR. ARCHITECT 423 FISCHER TRAIL, ELLIJAY, GEORGIA 30540 OF �O I �QVEZ 01A0 pgg9l6 Uc.410• mmm DESIGN GROUP 3450 Acworth Due West Road Building 100, Suite 120 Kennesaw, Georgia 30144 P.770-917-9172 F.770-917-9470 www.mrpdesign.com ISSUES/REVISIONS DATE DESCRIPTION 3. 18.20 COLORED ELEVATIONS 5UBMITTAL DRAWN BY: RGV CHK'D BY: RGV PROJECT TITLE: 2 >Q � L LN.L J U '� ^^ vJ `U`^) w vJ W � of 0 0- J X 0� W Q U SHEET TITLE: FLOOR PLAN RV.A.C. PROJECT NO: 19066 M101 :F.RTIFiCATF. OF At ITHORiZATION #006812 COMMERCIAL SPLIT SYSTEM AIR CONDITIONING SCHEDULE COOLING HTG INDOOR UNIT OUTDOOR UNIT UNIT AREA MANUFA NOM. CAPACITY CAP FAN ELECTRIC HEATER CONDENSER FANS) COMPRESSOR(S) WEIG MODEL WEIGH SEER HSPF NOTE(S) TC SC TOTAL OA E.S.P. FLA RLA LRA LABEL SERVED CTURER TONS @47°F MCA MOCP MCA MOCP HT (MBH) (MBH) (MBH) CFM CFM (IN) HP FLA V/0 KW STG V/0 T(LBS) QTY V/0 (EA) Q� V/0 (EA) (EA) (LBS) AHU-1/ LCN128HV4/ OFFICE LG 1 12.4 9.9 15.5 250 25 0.1 1.0 30 1 208/1 1.1 1 208/1 12.3 15 90 19.4 10.4 1-5 CU-1 LUU127HV NOTES: 1. PROVIDE WITH 410A REFRIGERANT. 2. PROVIDE A WALL MOUNTED, 7-DAY PROGRAMMABLE ELECTRONIC THERMOSTATAND WALL MOUNTED ZONE SENSOR. 3. ELECTRICAL CONNECTIONS FOR AHU FAN ARE PROVIDED THROUGH THE CONDENSING UNIT. 4. PROVIDE WITH CASSETTE GRILLE PT-UQC 5. CONTRACTOR TO PROVIDE & INSTALL 24 VAC MOTOROIZED DAMPER IN CA DUCT TO INTERLOCK WITH AHU OPERATION. AHU TRANSFORMER SHALL BE APPROPRIATELY SIZED TO POWER CA DAMPER. VENTILATION REQUIREMENT SCHEDULE SERVED BY ROOM SPACE TYPE NUMBER OF PEOPLE AIRFLOW RATE REQ'D PER PERSON (Rp) AREA (s1) OUTDOOR AIRFLOW RATE REQ'D PER SF (R,) Rp x P, R. x A, BREATHING ZONE OUTDOOR AIRFLOW ( bz) ZONE AIR DIST. EFFECT. (Ez) ZONE OUTDOOR AIRFLOW (Voz=Vbz/E,) OUTDOOR AIR INTAKE REQ'D (Vot) OUTDOOR AIR INTAKE PROVIDED OFFICE OFFICE SPACE 2 5 85 0.06 10 6 16 0.8 20 20 25 AHU-1 20 25 REQUIRED OUTSIDE AIR CFM VALUES BASED ON ASHRAE/ANSI 62.1-2019. EXHAUST FAN SCHEDULE UNIT S.P. MAX MOTOR AREA SERVED MANUFACTURER MODEL LOCATION TYPE DRIVE CFM NOTE(S) W HP RPM V/0 LABEL (IN WG) SONES 102 - PUBLIC EF-1 GREENHECK SP-A110 CEILING CENTRIFUGAL DIRECT 75 0.25 5 74 - 950 120/1 1 - 3, 5 RESTROOM 103 - PUBLIC EF 2 GREENHECK SP-A110 CEILING CENTRIFUGAL DIRECT 75 0.25 5 74 - 950 120/1 1 - 3, 5 RESTROOM RESTROOM EF-3 1 - I GREENHECK SP-A110 CEILING CENTRIFUGAL DIRECT 75 0.25 5 74 - 950 120/1 1 - 3, 5 105 - ELECTRICAL/ EF-4 GREENHECK SP-A390 CEILING CENTRIFUGAL DIRECT 300 0.25 5 135 - 1350 120/1 1, 3 - 5 EQUIPMENT RM 105-ELECTRICAL/ EC E -1 -43 L P O R DIRE 1 0 0 5 8 550 1 1 EQUIPMENT RM 101-INDOOR VAC EF-6 SPACE GREENHECK SP-A390 CEILING CENTRIFUGAL DIRECT 300 0.25 5 135 - NOTES: 1. PROVIDE WITH FAN SPEED CONTROLLER, BACKDRAFT DAMPER, DISCONNECT SWITCH. 2. FAN SHALL BE CONTROLLED BY LIGHT SWITCH. 3. FAN SOUND RATING SHALL BE 5 SONES OR LESS. 4. FAN SHALL BE CONTROLLED VIA LINE VOLTAGE THERMOSTAT SET TO 80 °F (ADJUSTABLE). 5. PROVIDE WITH GRILLE, FILTER FOR GRILLE AND BRICK VENT FOR WALL TERMINATION. 6. PROVIDE FAN SPEED CONTROLLER, WITH GRAVITY OPERATED DAMPER, OSHA GUARD, NEMA-1 SWITCH, DAMPER GUARD AND CLOSURE ANGLES. UNIT HEATER SCHEDULE UNIT AREA FUEL INPUT OUTPUT EFF MOTOR MANUFACTURER MODEL LOCATION HP KW V/0 LABEL SERVED SOURCE (MBH) (MBH) (%) CEILING NATURAL RHA 109-TUNNEL SPACE RAY PTS-40-N5 40 32 80% - - 120/1 HUNG GAS CEILING NATURAL IRH-2 109-TUNNEL SPACE RAY PTS-40-N5 40 32 80% - - 120/1 HUNG GAS CEILING NATURAL DJ-1 109 - TUNNEL DOOR JET JDTE 75 750 600 80% 1.5 - 480/3 HUNG GAS CEILING NATURAL DJ-2 109 - TUNNEL DOOR JET JDTE 75 750 600 80% 1.5 - 480/3 HUNG GAS 108 - EQUIP CEILING NATURAL UH-1 REZNOR UDAP60 60 50 83% 0.06 - 120/1 ROOM N G WALL UH-2 RESTROOM QMARK AWH4408F ELECTRIC - - 4 208/1 HUNG WALL UH-3 RESTROOM QMARK AWH4408F ELECTRIC 4 208/1 HUNG 2. PROVIDE B VENT TYPE FLUE AND HANGER KIT. 3. BURNER CONTROLS ARE TO BE ISOLATED FROM COMUSTION AIR. 4. ALL RADIANT TUBE IS TO BE ALUMINIZED STEEL CONSTRUCTION. 5. RADIANT TUBE LENGHTS SHALL NOT BE ANY SHORTER THAN INDICATED ON DRAWINGS. GRILLE/DIFFUSER SCHEDULE MARK CFM SEZE TYPE MFG MODEL NOTES 0-100 6X6 101-200 8X8 STEEL LOUVERED FACE A 201-400 10X10 SUPPLY DIFFUSER (4- PRICE SMD 1-5 401-525 12X12 WAY) 526-800 14X14 0-150 6X6 151-300 8X8 STEEL PERFORATED 301-500 10X10 CEILING OR SIDEWALL B PRICE PDDR 2-5 501-900 12X12 RETURN OR EXHAUST AIR 901-1400 14X14 GRILLE 1401-2100 18X18 0-150 12X12 151-300 18X12 WIND -DRIVEN RAIN 301-600 18X18 RESISTANT OUTSIDE AIR OAL, EL 601-850 24X18 GREENHECK EHH-601 4,6 INTAKE OR EXHAUST 851-1200 24X24 LOUVER 1201-1600 30X24 1601-2000 36X24 NOTES: 1. PROVIDE WITH OPPOSED BLADE BACKDRAFT DAMPER. 2. PROVIDE 24)(24 FULLY LOUVERED FACE LAYIN MODULE WHERE LOCATED IN LAYIN CEILING. 3. PROVIDE SQUARE TO ROUND NECK TRANSITION WHERE APPLICABLE. 4. COORDINATE BORDER TYPES WITH ARCHITECTURAL FLOOR PLAN AND REFLECTED CEILING PLAN, 5. COORDINATE FINISH WITH ARCHITECT. 6. LOUVER SHALL BE WIND -DRIVEN RAIN RESISTANT. 1350 120/1 1. 3 - 5 UNION DRAIN PAN EACH DIMENSION IS EQUAL TO FAN NEGATIVE STATIC PRESSURE 1 REMOVABLE CAP ROUTE TO NEAREST CONDENSATE RISER ON FULL SIZE OF DRAIN CONNECTION 3 CONDENSATE DRAIN DETAIL M201 SCALE: NTS NOTES SPIN -IN COLLAR MANUAL VOLUME DAMPER SUPPLY DUCT INSULATED FLEX DUCT (MAX LENGTH OF 4 FT) INSULATE BACK OF DIFFUSER CEILING DIFFUSER WIRE HANGER (TYPICAL) ROUND TO SQUARE ADAPTER OPPOSED BLADE DAMPER CEILING 1fl:7_Ci 1 DIFFUSER CONNECTION DETAIL M201 SCALE: NTS SQUARE ELBOW AIR FLOW MAX. DOUBLE L "� THICKNESS VANES L = 0.25xW BRANCH 3" MIN. DUCT SUPPLY TAP 4 DUCTWORK DETAILS M2017 SCALE: NTS GALV. STEEL OR ALUMINUM DUCT MADE WATERTIGHT. STIFFENERS MAY BE INSIDE. lo7_l9VAIIIII i17I9:iRemm SLOPED ROOF AT THE JOINING OF THE PIPE AND THE COLLARED ROOFCAP, CONNECT DUCT INSIDE COLLAR AND SEAL WITH FOIL BACKED TAPE. 1. PRIME COAT AND PAINT TO MATCH ROOF COLOR. 2. PROVIDE FLASHING AND COUNTER FLASHING. 3. PROVIDE BIRD SCREEN. 4. OUTSIDE AIR INTAKE SHALL BE A MINIMUM OF 10 FT. AWAY FROM ANY EXHAUST OR PLUMBING VENT. ROOF CAP DETAIL M201 SCALE: NITS ARCHITECT Of RECORD: OPTION 1: OPTION 2: THOMAS E. MORGAN, JR. 12 GAUGE WIRE OR 1/4" 1" WIDE 22 GAUGE STEEL ALL THREAD ROD TO STRAP WRAPPING UNDER ARCHITECT STRUCTURAL SUPPORT DUCT -,,",,"DUCT AND ATTACHED TO STRUCTURAL SUPPORT 8' MAX 1" 423FISCHERTRAIL ELLIJAY, GEORGIA 30540 1" X 2" X 1" 22 GAUGE ANGLE CHANNEL 4" X 2" X 2" - HANG FLEXIBLE DUCTS WITH 1" WIDE 22 GA. STEEL STRAPS WRAPPING UNDER DUCT EVERY 5 FT. MAX. ALSO SUPPORT 18" FROM ANY CONNECTION. MINIMUM 2" WIDE NO BURN RATE/SELF EXTINGUISHING FABRIC HANGER STRAP MAY BE USED IN LIEU OF METAL STRAPS 2 DUCT HANGER AND SUPPORT DETAILS M201 SCALE: NTS AIR FLOW 1 LOUVER FRAME BIRDSCREEN (OMIT FOR DRYER EXHAUST LOUVERS) O. -Q„ ��QUEZ ONQAqq16 45' L ©®© 3" M1 . LOUVER�� DESIGN GROUP DUCT RETURN TAP 2" METAL FLANGE. SECURE TO WALL WITH DRYWALL SCREWS. CAULK AIRTIGHT ALL AROUND - 3450 Acworth Due West Road Building 100, Suite 120 Kennesaw, Georgia 30144 P. 770-917-9172 F.770-917-9470 www.mrpdesign.com 5 WALL LOUVER DETAIL SSUES/REVISIONS SCALE: NTS once oE5cRlPrioN M20 1 08. 18 201 COLORED ELEVATON5 5UBMITAL 04/20/22 REVI5ICN I , MIN. 26 GAUGE GALVANIZED STEEL DRYER VENT IN WALL (MIN. 4") PROVIDE STAINLESS STEEL RADIATOR STYLE CLAMP FOR CONNECTION OF FLEXIBLE DRYER VENT. MIN. 26 GAUGE METAL BOX RECESSED IN STUD WALL. MIN. 18" / 8 DRYER WALL BOX DETAIL M201 SCALE: NTS SAVANT Engineering, LLC 5064 Roswell Road, Suite D-301 Sandy Springs GA 30342 770.319.7400 Project 20147 C2020 DRAWN BY: RGV CHK'D BY: RGV PROJECT TITLE: SHEET TITLE: H.V.A.C. SCHEDULES AND DETAILS PROJECT NO: 19066 M201 CERTIFICATE OF AUTHORIZATION #006812