HomeMy WebLinkAboutSDP202200005 Plan - Revision 2022-05-03CURVE TABLE
CURVE RADIUS ARC LENGTH TANGENT CHORD LENGTH CHORD BEARING DELTA ANGLE
1 GI 202.00' 55.45' 1-7.16' 35.39' 5 64014'20" W 10003'02"
11 535053 '54„E I _ _ 02 198.00' 1 55.51' 26.92' 55.54' S 6I"31'2I" W 15"29'00"
1fifil
RIGHlv1®Nr7) ROAD _ STATE ROUTE 250
Sff E PLAN
SCALE: I" = 20'-0"
LEGAL DESCRIPTION
LOT I-B, TAX MAP i8, PARCEL 55AZ, 16.3i ACRES 00053 5.FJ
GOVERNING CODES
BUILDING:
2015 VIR6INIA BUILDING CODE
MECHANICAL:
2015 VIR&INIA MECHANICAL CODE
PLUMBING:
2015 VIR6INIA PLUMBING CODE
ENERGY:
2015 VIR6INIA ENERGY CONSERVATION GORE
ELECTRICAL:
2014 EDITION NATIONAL ELECTRICAL CODE
FUEL / OAS:
2015 VIROINIA FUEL 6A5 CODE
FIRE:
2015 INTERNATIONAL FIRE CODE
ACCESSIBLE:
2009 EDITION OF AN51 AIITI
N320O5,08'yy
5.24'
VICINITY MAP
ROLKIN RD
PROJECT
LOCATION
/ \ NORTHi
V506NOTY MAP
NOT TO SCALE
SHEET INDEX
ARCHITECTURAL
A-1 PROJECT DATA 4 51TE PLAN
A-2 ENLARGED CANOPY PLAN
A-3 ELEVATIONS
A-4 MATERIALS AND PRODUCTS
A-5 PARTIAL LANDSCAPE PLAN
ELECTRICAL
E51D SITE PHOTOMETRIC PLAN
E52.1 PHOTOMETRIC PLAN (RECORD COPY)
E52.2 PHOTOMETRIC, DETAILS (RECORD COPY)
PROJECT DIRECTORY
OWNER:
CHICK-FIL-A, INC.
5200 BUFFINOTON ROAD
ATLANTA, 6A 30349
TROY TRIPP, DIRECTOR OF GONST
troy.trippeafacorp.com
(404) 305-4615
PROJECT MANAGER:
BUREAU VERITA5,LLG
1i200 N PERIMETER DRIVE
SUITE 2TS
SCOTTSDALE, ARIZONA 85255
MICHAEL ANDERSON, GPM
(480) TT7-I800
ARCHITECT:
E5ENGIA LLG
I-T43 E. McNAIR DRIVE
SUITE 200
TEMPE, AZ. 85283
JEFFREY WINTER, R.A.
winteroesenclo.org
(480) '155-0959 EXT 120
MUNICIPALITY:
ALBEMARLE COUNTY
401 MCINTIRE ROAD
CHARLOTTESVILLE, VA 220102
MIKE DELLIN6ER
mdellinger®al ,emarle.org
(454) 246-5832 x4504
PLUMB. / ELECT.
INTERPLAN LLG
220 E CENTRAL PARKWAY
SUITE 4000
ALTAMONTE 5PRIN65, FL 52-Tol
BARB MARTIN
Bmortinainterplon I Ic.com
(401) 645-5008
SITE PLAN KEYED NOTES
I. DASHED LINE INDIGATIN6 OUTLINE OF MEAL DELIVERY CANOPY.
2. DASHED LINE INDICATING OUTLINE OF FACE TO FACE CANOPY.
3. EXISTING VEHICLE DRIVE A15LE TO REMAIN.
4. EXISTING PARKING FIELD TO REMAIN, NO CHANGE.
5. EXISTING ORDER POINT MENU BOARD TO REMAIN. NO CHANGE.
6. EXISTING CONCRETE WALKWAY TO REMAIN.
T EXISTING CONCRETE CURB TO REMAIN, VERIFY EXI5TIN6
CONDITION OF CURB, REPLACE ANY DAMAGE OR BROKEN CURB
TO LIKE NEW CONDITION.
8. EXISTING CONCRETE ADA COMPLIANT ACCESSIBLE CURB. RAMP /
MARKED PATHWAY TO REMAIN.
11. EX15TINO LANDSCAPING AREA LANDSCAPE PLANTER TO REMAIN.
10. LOCATION OF ELECTRICAL AND/OR 6A5 CONNECTION. CONFIRM
UNDERGROUND UTILITIES PRIOR TO START OF CONSTRUCTION.
11. EXISTING CATCH BASIN ORATE TO REMAIN. VERIFY EXACT
LOCATION PRIOR TO START OF CONSTRUCTION.
12. EXISTING 6REA5E INTERCEPTOR TO REMAIN. VERIFY EXACT
LOCATION PRIOR TO START OF CONSTRUCTION.
15. OUTSIDE FACE OF EXIST. BUILDING EXTERIOR WALL.
14. EXIST. PROPERTY LINE.
15. EXIST. BUILDING SETBACK LINE.
16. EXI5TIN6 TRASH ENCLOSURE TO REMAIN.
Ii. EXI5TIN6 CANOPY STRUCTURES TO REMAIN. DO NOT DISTURB.
16. EXI5TIN6 UNDER61ROUND STORM WATER PIPING INDICATED BY
DASHED LINE. G.G. TO VERIFY EXACT LOCATION PRIOR TO
COMMENCING CONSTRUCTION.
Icl. LOCATION OF EXI5TIN6 CHICK-FIL-A MONUMENT 516N TO REMAIN.
PROJECT DATA
I. PROJECT NAME: CHICK-FIL-A, #3181
2. PROJECT ADDRESS: 1626 RICHMOND RD
CHARLOTTESVILLE, VA 22911
3. PROJECT WORK -SCOPE: INSTALLATION OF STEEL FRAMED FACE TO FACE
AND MEAL DELIVERY CANOPY (EMPLOYEE SHADE
STRUCTURES) WITH MINOR ELECT. / PLUMB. WORK.
4. PARCEL NO: 07600-00-00-055A2
5. ZONING: HO- HIGHWAY COMMERCIAL
6. PROPERTY AREA: Sg053 S.F. (1.64 ACRES)
1. FIRE SPRINKLERS: YES A.F.E.S. (EXISTING BUILDING)
6. TYPE OF CONSTRUCTION:
a.
EX15TINO BUILDING:
b.
NEW MEAL DELIVERY CANOPY
c.
NEW FACE TO FACE CANOPY
9. OCCUPANCY:
a.
EXISTING BUILDIN6:
b.
NEW MEAL DELIVERY CANOPY
c.
NEW FACE TO FACE CANOPY
10. BUILDIN6
AREA:
a.
EX15TINS BUILDING:
b.
NEW MEAL DELIVERY CANOPY
c.
NEW FACE TO FACE CANOPY
VB (EXIST. UN -CHANGED)
IIB
IIB
A-2 (EXIST. UNCHANGED)
A-2
U (ACCESSORY USE TO A-2)
50. FT. OCCUPANCY
4,835 S.F. A-2 (EXI5TIN6)
424 S.F. A-2
880 S.F. U (ACCESSORY USE)
d. TOTAL AREA: 6,1341 S.F.
11. ALLOWABLE AREA: PER VBG TABLE 506.2
a. FIRE SPRINKLERED BUILDING: 24,000 S.F. (EXIST. I-5TORY BLD6)
"b. ACTUAL BUILDING AREA: 6,139 S.F.
• NOTE: INCLUDED NEW CANOPIES IN TOTAL AREA IN CALCULATIONS
12. AREA OF CONSTRUCTION: 1,304 5.F
13. CANOPY HEIGHT:
a. MEAL DELIVERY CANOPY: 9'-6" BOTT. OF CANOPY
b. FACE TO FACE CANOPY 9'-6" BOTT. OF CANOPY
14. BUILDING SETBACKS
a. NORTH PROP LINE: 20'-0"
b. WEST PROP LINE: 50'-0" (RICHMOND STATE RD)
c. SOUTH PROP LINE: 20'-0"
d. EAST PROP LINE: 20'-0" (LUXOR RD)
15. PARKING REQUIREMENTS:
EXI5TIN6 TO REMAIN NO GHAN6E TO PARKING SPACES OR EXI5TIN6 DRIVE
THRU LANES.
SWPP GENERAL NOTE
NOTE TO CITY / COUNTY EN6INEERIN6 DEPT. THE CONSTRUCTION OF THE
THI5 PROJECT DOES NOT REQUIRE ANY OUT / FILL OR GRADING. ALL
FOOTING-5 REGARDLESS OF TYPE ARE EXCAVATED ON THE FIRST DAY OF
CONSTRUCTION, EXCESS DIRT HAULED OFF IMMEDIATELY AND DISPOSED OF
PER CITY / COUNTY REQUIREMENTS. ALL TRENCHING 15 DUG, ELECTRICAL
AND OR 6A5 LINES INSTALLED, TRENCH 15 BAGKFILLED ON THE SAME DAY.
NO 6RADIN6 ELEVATIONS GHAN5E5 OCCUR NOR P15TURBANCE OF ANY
WATER DRAINA6E PATTERNS. PERVIOUS OR NON-PEREVIOU5 AREAS ARE
NOT AFFECTED. THEREFORE A STORM WATER PREVENTION PLAN 15 NOT
REQUIRED FOR THI5 PROJECT.
GENERAL NOTES
A. PRIOR TO COMMENCEMENT OF CONSTRUCTION THE O.C. SHALL BE
RESPONSIBLE TO VERIFY AND LOCATE EXALT LOCATION/DEPTH OF
UNDERGROUND UTILITY LINES, COMMUNICATION LINES, ETC. 5ERVIN6 THI5
SITE. IDENTIFY UTILITIES AS TO SCOPE OF WORK AND LOCATION OF
DIG61 N6.
B. WHERE REQUIRED. 6.0. SHALL NOTIFY ADJACENT TENANTS / PROPERTY
OWNERS OF ANY SERVICE INTERRUPTIONS AT LEAST 46 HOURS PRIOR TO
SERVICE INTERRUPTIONS.
G. ANY DAMA&E5 TO UNDERGROUND UTILITY LINES SHALL BE REPORTED TO
THE UTILITY COMPANY INVOLVED. O.C. SHALL REPAIR DAMAGES PER
UTILITY CO. REQUIREMENTS AT CONTRACTOR5 EXPENSE.
D. UPON INSTALLATION OF FOOTIN65, IT SHALL BE THE 6.0 RESPONSIBILITY
TO OBTAIN THE SERVICES OF A LAND SURVEYOR TO PROVIDE TOP OF
ASPHALT/GONG. DIVE TOPO POINTS TO THE CANOPY FABRICATOR PRIOR
TO CANOPY FABRICATION. SAID LAND SURVEYOR SHALL PROVIDE A
DRAWING DEPICTING TOPO POINTS, NO EXCEPTIONS TAKEN.
E. ALL 51TE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED TO
REACH, AND BE MAINTAINED AT, MATURE HEIGHT; THE TOPPING OF TREES
15 PROHIBITED, 5HRU55 AND TREES SHALL BE PRUNED MINIMALLY AND
ONLY TO SUPPORT THE OVERALL HEALTH OF THE PLANT.
APPROVAL BLOCK
5200 BUFFINGTON ROAD.
ATLANTA, GEORGIA 30349
(404) 765 - 8000
THESE PLANS AND SPECIFICATIONS, AS WELL AS
CHICK-FIL-A, INC. NAME AND LOGO, TRADEMARKS AND
DESIGNS ARE THE EXCLUSIVE PROPERTY OF
CHICK-FIL-A CORPORATION. ANY REPRODUCTION,
MODIFICATION, DISCLOSURE AND/OR USE OF
THESE MATERIALS (OR ANY PORTION OF THEM)
WITHOUT CHICK-FIL-ASS PRIOR WRITTEN CONSENT
IS STRICTLY PROHIBITED.
esencia
0
1743 E. McNair Drive,
Suite 200
Tempe , Arizona
85283
Telephone 480-755-0959
V
TH04p
JEFFREY W. WINTER
Lie. No. 015908
.-1RCHI-Tr
08-02-2C21
Revision Schedule
Rev
Date
By
Description
r
r
N
N
NQ
M�
W
0
Q
L.L
Q
\
/
J
J_
z
'�/�
I1
O
O
G
ry
Q
0o
()�
0
-0
Co
Z
U
UU)
'-0u
2
4)
O
a`
Issue Date:
08-02-2021
Drawn By:
TP/GA
Job Number:
19060
Sheet Title:
Project Data
Site Plan
Scale: As indicated
Sheet Number:
A-1
GENERAL NOTES
0 CONSTRUCTION NOTES - MEAL DELIVERY
a. THE DIMENSIONS SHOWN ON THESE DRAWINGS ARE TO
A.
NEW SHADE CANOPY STEEL SUPPORT COLUMN WITH CONCRETE FOOTING
CENTER OF COLUMN LINE ONLY AND HAVE BEEN
BELOW. SEE STRUCTURAL DRAWIN65 FOR FURTHER DETAILS. EXI5TIN5
ESTABLISHED IN ACCORDANCE WITH GHIGK-FIL-A
CONCRETE / LAND50APIN6 TO BE REPAIRED OR REPLACED AS REQUIRED
STANDARD DESIGN 6UIDELINE5.
PROVIDE FLUSH TRANSITION BETWEEN NEW AND EXIST. GONG. SURFACES.
b. COLUMNS SHALL BE INSTALLED IN A MANNER A5 NOT
B.
EXISTING CONCRETE CURB TO REMAIN. SAW GUT AND REMOVE PORTION OF
TO DISTURB THE EXISTING EXTERIOR BUILDING
CURB AS REQUIRED FOR INSTALLATION OF NEW FOOTING. UPON FOOTING
FOUNDATIONS NOR UNDERMINE THE EXISTING
INSTALLATION O.C. SHALL PATCH AND REPAIR EXIST. CURB AS REQUIRED.
EXTERIOR BUILDING STEM WALLS/FOOTIN65.
PROVIDE SMOOTH TRANSITION BETWEEN NEW AND EXIST. CONC. CURB. C.G.
SHALL REPLACE ANY KNOWAI CRACKED OR DAMAGED ON SITE CONC.
c. WHERE AN OFFSET CAISSON FOOTING OR SPREAD
CURBING (TYP).
FOOTIN6 15 REQUIRED, THE 6.0 SHALL COORDINATE
THE EXI5TIN6 FIELD CONDITIONS TO THE CANOPY
G.
EXI5TIN6 CONCRETE WALKWAY TO REMAIN
FABRICATOR FOR APPROVAL PRIOR TO
INSTALLATION OF THE FOOTIN65.
D.
EXISTING LAND50APING AREA TO REMAIN.
�/ }�
EX 1ST 1 I ` O
d. COLUMNS NEEDING TO BE RELOCATED INTO THE DRIVE
E.
DASHED LINE INDICATING OUTLINE OF OVERHEAD CANOPY.
GHIGK-1= L-f�
LANE OR TEAM WALK WAY, THE G.G. SHALL NOTIFY
REFER TO CANOPY SHOP DRAININCS WITH -IN THIS SET.
THE FIELD CONSTRUCTION MANAGER TO GAIN PROPER
,( p
APPROVAL FROM CHICK-FIL-A PRIOR TO
COMMENCEMENT OF SAID CONSTRUCTION WORK.
F.
FACE OF EXI5TIN6 EXTERIOR BUILDING WALL. DO NOT DISTURB.
I
I i
1
6.
X/Y DIMENSION SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. 6G TO FIELD
6C TO CONFIRM SIZE, DEPTH AND LOCATION OF
VERIFY EXACT LOCATION AND NOTIFY CHICK-FIL-A PROJECT TEAM IF
UTILITIES PRIOR TO CONSTRUCTION.
CANOPY LOCATION CHANCES AND IMPACTS OTHER CONSTRUCTION RELATED
f. 6C TO CONFIRM DIMENSIONS OF CURBS AND EXACT
p
1
LOCATION OF PICK-UP WINDOW PRIOR TO
H.
EXI5TIN6 MEAL DELIVERY PICK UP WINDOW. DO NOT DISTURB.
D d
I
I
CONSTRUCTION.
1
J.
EXISTING BOLLARD TO BE REMAIN. DO NOT DISTURB
I
" -
L
1
K.
DASHED LINE INDIGATINC EXI5TIN6 AWNING TO BE REMOVED. 60 TO REPAIR
�
4-0��
EXIST. EXTERIOR WALL AS REQUIRED APPLY TOUGH -UP PAINT FIELD MATCH
\
I
EXIST. COLOR AND WALL FINISH. PROVIDE FLUSH TRANSITION FOR ALL
y
-
PATCH WORK.
\
\
�
L.
EXISTING AWNING TO REMAIN. NO CHANGE.
�
\ O A _.
�0
M.
EXISTING DRIVE THRU LANE TO REMAIN.
� a
\ `fl = , \�
N.
EXISTING SECURITY CAMERA TO REMAIN.
\FJ + \\
I
P.
EXISTING LIGHT FIXTURE TO REMAIN. DO NOT DISTURB.
I
�
I
\
ti? U
Q.
EASEMENT LINE SHOWN FOR REFERENCE. SEE 51TE PLAN.
P K g A J H B
=� \
\+
N TYP. I 1
I
i /,.\
U
R
SETBACK LINE SHOWN FOR REFERENCE. SEE 517E PLAN.
-------------- -J
F
� � � 1
5.
EXISTING CANOPY STRUCTURE TO REMAIN. DO NOT DISTURB.
E `�"
I�
T.
EXISTING RETAINING WALL SHOWN FOR REFERENCE. SEE 517E PLAN.
\x\x
U.
EXIST. GUARD RAIL TO REMAIN, SHOWN FOR REFERENCE.
I
L -cam\-
T
max,
REFERENCE:
LEGEND
ENLARGED RGED CANOPY pY D� TALLATDON
PLAN - MEAL DC���MERY CANOPY
F> � CANOPY LIGHTS
SCALE: /b" = 1'-0".
FAN5
NORTH
SCALE: I/8" =
I'-O"
SEE STRUGT. DRAWINGS
0' 4' 8' 16'
0 HEATERS
GENERAL NOTES
CONSTRUCTION NOTES - FACE TO FACE
a. THE DIMENSIONS SHOWN ON THESE DRAWIN65 ARE TO CENTER OF COLUMN LINE
ONLY AND HAVE BEEN ESTABLISHED IN ACCORDANCE WITH CHICK-FIL-A STANDARD DE516N 6UIDELINE5.
I.
NEW SHADE CANOPY STEEL SUPPORT COLUMN WITH CONCRETE FOOTING
BELOW. SEE STRUCTURAL DRAWINGS FOR FURTHER DETAILS. EXISTING
b. COLUMNS SHALL BE INSTALLED IN A MANNER AS NOT TO DISTURB THE EXISTING EXTERIOR BUILDING
CONCRETE / LANDSCAPING TO BE REPAIRED OR REPLACED AS REQUIRED
/
®
FOUNDATIONS NOR UNDERMINE THE EXISTING EXTERIOR BUILDING STEM WALL5/FO0TIN65.
PROVIDE FLUSH TRANSITION BETWEEN NEW AND EXIST. CONC. SURFACES.
t
c. WHERE AN OFFSET CA15WN FOOTING OR SPREAD FOOTIN6 IS REQUIRED, THE 6.0 SHALL COORDINATE THE
2.
EXI5TIN6 CONCRETE CURB TO REMAIN. SAW GUT AND REMOVE PORTION OF
EX I CS I I ` O
EXI5TIN6 FIELD CONDITIONS TO THE CANOPY FABRICATOR FOR APPROVAL PRIOR TO INSTALLATION OF THE
CURB AS REQUIRED FOR INSTALLATION OF NEW FOOTING. UPON FOOTING
FOOTINGS.
INSTALLATION G.G. SHALL PATCH AND REPAIR EXIST. CURB AS REQUIRED.
PROVIDE SMOOTH TRANSITION BETWEEN NEW AND EXIST. GONG. CURB. 6.0.
d. COLUMNS NEEDING TO BE RELOCATED INTO THE DRIVE LANE OR TEAM WALK WAY, THE G.G. SHALL NOTIFY
THE FIELD CONSTRUCTION MANAGER TO GAIN PROPER APPROVAL FROM CHICK-FIL-A PRIOR TO
SHALL REPLACE ANY KNOWN CRACKED OR DAMAGED ON 51TE
GONG. CURBING (TYP).
COMMENCEMENT OF SAID CONSTRUCTION WORK.
3.
EXISTING CONCRETE WALKWAY TO REMAIN.
14
e. 6C TO CONFIRM SIZE, DEPTH AND LOCATION OF UTILITIES PRIOR TO CONSTRUCTION.
/
46'-O'
b
f. 60 TO CONFIRM DIMENSIONS OF CURBS AND EXACT LOCATION OF PICK-UP WINDOW PRIOR TO
CONSTRUCTION.
4.
5.
EXI5TIN6 LAND5GAPIN6 AREA TO REMAIN.
NEW 24" WIDE TEAM MEMBER DEMARCATION STRIPING. USE TRAFFIC RATED
\ j
PAINT. MIN. (2) COATS.
b.
FACE OF EXISTING EXTERIOR BUILDING. WALL - DO NOT DISTURB.
i'-O" 17'-O" 1'T'-O" -I'-O"
/% /
b"m X 42" H.
?.
X/Y DIMENSION SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. 6C TO FIELD
VERIFY EXALT LOCATION OF COLUMN STARTING POINT. NOTIFY CHICK-FIL-A
3
/
/
-7 �5,_b„
/ 10 /
TUBE
STEEL PIPE BOLLARD
FILLED WUGONGRETE
b.
PROJECT TEAM OF ANY VISC
PHASES OR RELATED CONDITIOONNS. TES IMPAGTIN6 OTHER CONSTRUCTION
EXISTING DRIVE THRU ORDER POINT MENU BOARD CANOPY TO BE REMOVED,
CENTERLINE OF
INDICATED BY DASHED LINE. SPEAKERS TO REMAIN. DO NO DISTURB.
BOLLARD
EXIST. CONG. SLAB.
41.
LOCATION OF NEW BOLLARD. PER CHICK-FIL-A DESIGN STANDARD INSTALL
E
PROVIDE FLUSH 0
'
24" FROM FACE OF CLEARANCE BAR AND/OR LAST CANOPY COLUMN AS
/
4 O
I
� �� \0
_ _ _ _
fi
PAINTED PIPE TRAN51TION BETWEEN m
BOLLARD FOOTING AND
SHOW ON DRAWING5. REFER TO DETAIL.
-
I
- - �
MI. (2) GOATS
/
II
I 18 5
U / i+
TRAFFIC, ST. TOP (TYPJ F
10.
II.
EXISTING BOLLARD TO BE REMAIN.
EXISTING CLEARANCE BAR TO REMAIN. DO NOT DISTURB.
5 I
/
FIN. 6RADE
12.
DASHED LINE INDICATING OUTLINE OF OVERHEAD CANOPY. REFER TO
CANOPY DRAWIN65 WITHIN -IN THIS SET.
5
15.
EASEMENT LINE SHOWN FOR REFERENCE. SEE 517E PLAN.
14.
SETBACK LINE SHOWN FOR REFERENCE. SEE SITE PLAN.
- - -
_ --
—
L ------------------ — — — — — — — — —
A e
++
=III=III=III—III ' I —III —III —III —I
= a = 1= I I I
- IEI 11=1 11—III—II1 11- —III=1
-111==11I—II'
15.
EXISTING 5� RETAINING WALL SHOWN FOR REFERENCE. 517E PLAN
,0
I b
q
A-2 12
"
—11 =111-
1= -111-1
El I=l I1=
El
11111 to
_11'
Ib.
Ii.
EXISTING CANOPY TO REMAIN. DO NOT DISTURB.
DASHED LINE INDICATING EXI5TIN6 AWNING TO BE REMOVED. 6C TO REPAIR
CONG FOOTING �
EXIST. EXTERIOR WALL A5 REQUIRED APPLY TOUCH-UP PAINT FIELD MATCH
-
-� .—"—x•—■—•.—.
/
:111= 111—
°
EXIST. COLOR AND WALL FINISH. PROVIDE FLUSH TRANSITION FOR ALL
PATCH WORK.
--"
i
:1°�
11=1
/
El I
:1= °
I
16.
DASHED LINE INDICATING LOCATION OF EXIST. UNDER6ROUND STORM WATER
PIPING TO REMAIN. 6.0. TO VERIFY EXACT LOCATION OF PIPING PRIOR TO
m
LEGEND
I
—1 1=1 a=11 1 u=1 a 1
COMMENCING GONST.
1�1I„ 1-I
IQ.
EXIST. STORM WATER CATCH BA51N GRATE TO REMAIN. VERIFY EXACT
ORTH
11I111111
LOCATION PRIOR TO START OF CONSTRUCTION.
F_ 1'-6" 41
CANOPY LIGHTS
ENLARGED CANOPY MTALLATT ON
PLAN - FACE TO FACE CANOPY PY
o4' 8' 16' � FANS
TOPIC AL BOLLARD DIETML
Q
SCALE: 1/8" =
1'-0"
5EE 5TRUGT. DRAWINGS ® HEATERS
SCALE: 5/4" = 1'-0"
5200 BUFFINGTON ROAD.
ATLANTA, GEORGIA 30349
(404) 765 - 8000
THESE PLANS AND SPECIFICATIONS, AS WELL AS
CHICK-FIL-A, INC. NAME AND LOGO, TRADEMARKS AND
DESIGNS ARE THE EXCLUSIVE PROPERTY OF
CHICK-FIL-A CORPORATION. ANY REPRODUCTION,
MODIFICATION, DISCLOSURE AND/OR USE OF
THESE MATERIALS (OR ANY PORTION OF THEM)
WITHOUT CHICK-FIL-ASS PRIOR WRITTEN CONSENT
IS STRICTLY PROHIBITED.
esencia
0
1743 E. McNair Drive, Suite 200
Tempe, Arizona 85283
Telephone 480-755-0959
V
H OA
JEFFRE r W. WRTMR
Lic. NO.015908
�RCHITBG�
08-02-2C21
Revision Schedule
Rev
Date
By
Description
r
r
N
N
�Q
W 0
Q
LL
Q
\
o
CM 0
LU
J
J
�� Z%
I..
O
i LLI OC
W G
w
Q
0o
()�
U
-p
E
Co
Z
U
N
2
2
a
Issue Date:
08-02-2021
Drawn By:
TP/GA
Job Number:
19060
Sheet Title:
Enlarged Canopy
Plan
Scale: As indicated
Sheet Number:
A-2
301
B. O. GNPY
+ '-O"
T.O.OP.
FRONT ELEVATION (EAST) MEAL DELIVERY CANOPY
SCALE: I/8" = 1'-0"
*]Mmll►VIE=MTdHl=MIU1E=I AE�V/ArTdll*] ► 9(&ST* UkTlHi)�MIE�A\ MD7 :E4 MI\VI E�mmYL07A\ ► COO7 FYI
SCALE: 1/5" = I'-0"
5EE 5TRUGT. DRAWINGS
jftgi REAR ELEVATION (WEST) FACE TO FACE CANOPY
SGALE: 115" = 1'-0"
SIDE ENTRY ELEVATION (NORTH) FACE TO FACE CANOPY
SCALE: I/8" = I'-0"
5EE 5TRUGT. DRAWINGS
5EE 5TRUCT. DRANIN55
_ +q'-6"
B. 0. GNPY
+ O'-04
T.O.P.
SEE STRUGT. DRAAN55
B. 0. GNPY
+ O'-O"
T.O.P.
B. 0. GNPY
+ 0'-01,
T.O.P.
0 CONSTRUCTION NOTES - MEAL DELIVERY
A. EXISTING BUILDING AND FINISHES TO REMAIN. NO WORK IN THI5 AREA.
B. MEAL DELIVERY PICK UP WINDOW. LOCATED BEHIND SCREEN WALL TO REMAIN.
C. TOP OF EXISTING CONCRETE WALKWAY TO REMAIN.
D. TOP OF EX15TINO DRIVE THRU LANE TO REMAIN.
E. DASHED LINE INDICATING EXISTING AWNING TO BE REMOVED. G.G. SHALL REPAIR OR
REPLACE EXISTING FINISHES AS REQUIRED. MATCH EXISTING GROUT, VENEER.
F. EXISTING AWNING TO REMAIN. NO CHANGE.
6. NEN CANOPY STEEL SUPPORT COLUMN. SEE STRUCTURAL DRAWINGS FOR MORE DETAIL.
COLOR: DARK BRONZE.
H. NEW CANOPY ROOF / FASCIA.
UNDERSIDE TO BE COLOR: LANE HIGH &LOSS WHITE.
ROOF / FASCIA TO BE COLOR: DARK BRONZE.
J. NEH CANOPY INDUSTRIAL MOUNTED IS" FAN. TPI CORPORATION MODEL: U-18-TE. REFER TO
ELECT. DRANIN65 FOR FURTHER DETAILS.
K. NEW CANOPY OVERHEAD HEATER BY SUPREME 5CHWANK. MODEL: 2552 N OUTDOOR. REFER
TO PLUMB/ ELECT. PRAHIN65 FOR FARTHER DETAILS.
L. NEW MEAL DELIVERY METAL CANOPY. COLOR: DARK BRONZE, REFER TO CANOPY DRAHIN65
FOR FURTHER DETAILS.
M. NEH FACE TO FACE METAL CANOPY, REFER TO CANOPY DRAWINC75 FOR FATHER DETAILS.
P. EXISTING, ORDER MENU BOARD TO REMAIN. NO CHANGE.
R. EXI5TIN57 CANOPY STRUCTURE WITH 50REEN WALL TO REMAIN. DO NOT DISTURB.
O I FINISH 50HEDULE
LANE
P-I CANOPY COLOR — UNPER51PE
HIGH WHITE OL055
P-2 I CANOPY ROOF / FA5GIA: DARK BRONZE
CONSTRUCTION NOTES - FACE TO FACE
I. EXISTING BUILDING AND FINISHES TO REMAIN. NO WORK IN THIS AREA.
2. TOP OF EXISTING CONCRETE WALKWAY TO REMAIN.
3. TOP OF EXISTING DRIVE THRU LANE TO REMAIN.
4. EXISTING MAIN ENTRY.
S. EXISTING AWNING TO REMAIN. NO CHANGE.
b. NEW CANOPY STEEL SUPPORT COLUMN. SEE 5TRUGTURAL DRAHIN65 FOR MORE DETAIL. COLOR:
DARK BRONZE.
1. NEN CANOPY ROOF / FASCIA.
UNDERSIDE TO BE COLOR: LANE HIGH OL055 WHITE.
ROOF / FASCIA TO BE COLOR: DARK BRONZE.
6. NEW CANOPY INDUSTRIAL MOUNTED 16" FAN. TPI CORPORATION MODEL: U-16-TE. REFER TO
ELECT. DRAHIN65.
q. NEN CANOPY OVERHEAD HEATER BY SUPREME SCHWANK. MODEL: 2352 N OUTDOOR. REFER TO
PLUMBJELECT. DRAWINGS FOR FURTHER DETAILS.
10. NEW FACE TO FACE METAL CANOPY. COLOR: DARK BRONZE. REFER TO CANOPY SHOP
DRAHINC75 FOR FURTHER DETAILS.
II. NEN MEAL DELIVERY METAL CANOPY, REFER TO CANOPY SHOP DRAWINC75 FOR FURTHER
DETAILS.
12. DASHED LINE INDICATING EXISTING AWNING TO BE REMOVED. 6.0. SHALL REPAIR OR REPLACE
EXISTING FINISHES AS REQUIRED. MATCH EXISTING GROUT, VENEER.
WWI
FINISH 50HEDULE
LANE
P-1 CANOPY COLOR — UNDERSIDE
HIGH WHITE OL055
P-2 I CANOPY ROOF / FASCIA: JET MATTE BLACK
5200 BUFFINGTON ROAD.
ATLANTA, GEORGIA 30349
(404) 765 - 8000
THESE PLANS AND SPECIFICATIONS, AS WELL AS
CHICK-FIL-A, INC. NAME AND LOGO, TRADEMARKS AND
DESIGNS ARE THE EXCLUSIVE PROPERTY OF
CHICK-FIL-A CORPORATION. ANY REPRODUCTION,
MODIFICATION, DISCLOSURE AND/OR USE OF
THESE MATERIALS (OR ANY PORTION OF THEM)
WITHOUT CHICK-FIL-A'S PRIOR WRITTEN CONSENT
IS STRICTLY PROHIBITED.
esencia
0
1743 E. McNair Drive,
Suite 200
Tempe, Arizona
85283
Telephone 480-755-0959
d
TH 6
JEFFREY W. WIWMR
Uc. No. 015908
ARCHITgG�
08-02-2C21
Revision Schedule
Rev
Date
By
Description
r
r
N
N
Q
M
0
Q
o
CM
0
LU
J
J
LL
z
/
O
w
O
2
w
0o
Q
()�
-0co
E
cc
Z
U
U�
�
u
�o
a
Issue Date:
08-02-2021
Drawn By:
TP/GA
Job Number:
19060
Sheet Title:
Elevation Plan
Scale: As indicated
Sheet Number:
A-3
V`
VI
1
1
1
1
1
1
1
1
1
1
i
i
MEAL DELIVERY CANOPY, 9'-6" CLEAR ABOVE PAVEMENT (SITE SPECIFIC) - CONTEXT VIEW.
MEAL DELIVERY CANOPY, 9'-6" CLEAR ABOVE PAVEMENT (SITE SPECIFIC) - FRONT VIEW.
y
MATERIAL SAMPLES
CANOPY DECK - UNDERSIDE FACE
COMPANY: LANE 5UPPLY, INC.
COLOR: LANE HIGH OL055 WHITE
CANOPY LIGHT
�, SC - Standard Symmetric
--� - Asymmetric
AC distribution utilizes a reflector which alters the
look from a standard S distribution
CANOPY ROOF
COMPANY: LANE 5UPPLY, INC.
COLOR: JET MATTE BLACK
OVERHEAD PATIO HEATER
LED CANOPY LI5HT - LE5ACY (GRU5) SUPREME 5GHWANK
MODEL: LIGHT OUTPUT - CRU5 MODEL: 2552 N OUTDOOR
COLOR: COOL WHITE
INDU5TRIAL MOUNTED
PgORK5TATION FAN
TPI CORPORATION
MODEL: U-IS-TE
FAN 51ZE: IV'
1
1
1
1
1
1
1
1
1
1
1
i
i
MEAL DELIVERY CANOPY, 9'-6" CLEAR ABOVE PAVEMENT (SITE SPECIFIC) - CONTEXT VIEW.
MEAL DELIVERY CANOPY, 9'-6" CLEAR ABOVE PAVEMENT (SITE SPECIFIC) - FRONT VIEW.
5200 BUFFINGTON ROAD.
ATLANTA, GEORGIA 30349
(404) 765 - 8000
THESE PLANS AND SPECIFICATIONS, AS WELL AS
CHICK—FIL—A, INC. NAME AND LOGO, TRADEMARKS AND
DESIGNS ARE THE EXCLUSIVE PROPERTY OF
CHICK—FIL—A CORPORATION. ANY REPRODUCTION,
MODIFICATION, DISCLOSURE AND/OR USE OF
THESE MATERIALS (OR ANY PORTION OF THEM)
WITHOUT CHICK—FIL—A'S PRIOR WRITTEN CONSENT
IS STRICTLY PROHIBITED.
esencia
■
1743 E. McNair Drive,
Suite 200
Tempe, Arizona
85283
Telephone 480-755-0959
V TH OF
JEFFREY W. WINTER
Lia No. 015905
ARCHITB��
08-02-2021
Revision Schedule
Rev
Date
By
Description
N
N
Q
0�
W
0
Q
r
Q
o
CM
0
w
J
J
z
i
O
0
2
W
0o
Q
()�
-0co
E
to
Z
U
U�
�
4)
u
O
a`
Issue Date:
08-02-2021
Drawn By:
TP/GA
Job Number:
19060
Sheet Title:
Materials &
Products
Scale: As indicated
Sheet Number:
A-4
GENERAL NOTES
O
CONSTRUCTION NOTES - MEAL DELIVERY
A.
ALL SITE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED
A.
EXISTING 5HRUB5 TO REMAIN. 6.0. TO REPLACE ANY DYING/ DEAD/
TO REACH, AND BE MAINTAINED AT, MATURE HEIGHT, THE TOPPING
MI55IN57 5HRUB5, REFER TO RECORD COPY OF LANDSCAPE PLAN FOR
OF TREES 15 PROHIBITED, 5HRUB5 AND TREES SHALL BE PRUNED
QUANTITY.
MINIMALLY AND ONLY TO SUPPORT THE OVERALL HEALTH OF THE
A
PLANT.
B.
DASHED LINE INDICATING CANOPY FOOTING LOCATION.
B.
INSPECTION
G
(2) NEW BTHP SHRUBS AFTER INSTALLATION OF CANOPY
\
E v I GT 1 � 0
/� ✓ I `l
PLANNING DEPARTMENT PRIOR TO G OF 0. (INSPECTION.
FOOTING.PLANT
GH I GK-F I L-A
G.
5.0. SHALL MODIFY EXISTING IRRIGATION LINE(5) AS REQUIRED
D.
DASHED LINE INDICATING S.C. TO REMOVE (5) LMPI FOR FOOTING
INSTALLMENT.
C \.
FOR RELOCATED OR ADDED LANDSCAPING.
\
\
� D
\
B
\
I
I
\
A
\
\ F -
I I
PLANT LIST
=------------------------�!
\
I
ABBREVIATION
BOTANICAL NAME
COMMON NAME
SIZE
SPACING
'
I
\
CV
CHIONANTHU5
WHITE FRINGE
b' - i'
AS SHOWNS
_
3
I
VIROINIGU5
TREE
\*�
-------
2' O.G.
BTHP
BERBERIS THUNBERC711
HELMOND PILLAR
50' MIN.
i
WI
'HELMOND PILLAR'
BARBERRY
AXGK
ABELIA X &RANDIFLORA
'KALEIDOSCOPE'
KALEIDOSCOPE ABELIA
24"/ 3 GALLON MIN.
O.G.
\° IL — -- — t — — -
--
L
— — —
— — — —
LMPI
LIRIOPE MUSGARI
PEEDEE INGOT'
PEEDEE INGOT
LIRIOPE
I GALLON
„ „
12 -IS O.G.
SCALE: 1/4" = I'-0"•
NORTH
LMWN
LA WIHITE NANCYUM NM
i WHITE MANGY LAMIUM
I QUART MIN.
24" O.G.
I� /A� lowT� /A� L L /A� f�flDC� C n F 2 PLAN f�fl - MEAL /n� L D2L�n0ER�\/l 0' 2' 4' 8'
1SCAALIfEms: V �JV�G�1I� LS I� G�1UV V LSG�1 LS V LSITl7 f
/ 1 ,
1/4G"�1= 1'-O'G'�1
HDL
HEMEROGALLI5 'RED
RED HOT RETURNS
I GALLON
24" O.G.
HOT RETURNS
DAYLILY
GENERAL NOTES
O
CONSTRUCTION NOTES - FACE TO FACE
}
\
E:X I ST I NCB
A.
ALL SITE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED
TO REACH, AND BE MAINTAINED AT, MATURE HEIGHT, THE TOPPING
I.
EXISTING 5HRUB5 TO REMAIN. S.C. TO REPLACE ANY DYING/ DEAD/
/
MISSING SHRUBS, REFER TO RECORD COPY OF LANDSCAPE PLAN FOR
GH I GK-F I L-
OF TREE5 15 PROHIBITED, SHRUBS AND TREES SHALL BE PRUNED
MINIMALLY AND ONLY TO SUPPORT THE OVERALL HEALTH OF THE
QUANTITY.
PLANT.
2.
G.G. TO INSTALL (2) CV MISSING TREES, REFER TO RECORD COPY OF
/
64/55 S.F.)
\
LANDSCAPE PLAN.
\
B.
S.C. SHALL GALL FOR LANDSCAPE INSPECTION WITH CITY
2
\
\
\
//
/
PLANNING DEPARTMENT PRIOR TO C. OF O. INSPECTION.
3.
EXISTING GROUND COVER TO REMAIN. S.C. TO REPLACE ANY DYING/
\
DEAD/ MISSING GROUND COVER WITH NEW PLANTS, REFER TO RECORD
G.
G.G. SHALL MODIFY EXISTING IRRIGATION LINES) AS REQUIRED
COPY OF APPROVE LANDSCAPE PLAN FOR QUANTITY.
FOR RELOCATED OR ADDED LANDSCAPING.
* \
Ty'P'
2 8
4.
5.
DASHED LINE INDICATING CANOPY FOOTING LOCATION.
O.C. TO REPLANT (3) NEW LMWN AFTER INSTALLATION OF CANOPY
FOOTING.
l )
\
b.
DASHED LINE INDICATING 6.0. TO REMOVE (6) LMWN FOR FOOTING
T
—
r —
�i�� L
S
INSTALLATION.
/
T,
DASHED LINE INDICATING G.G. TO REMOVE (1) LMPI FOR FOOTING
INSTALLATION.
D.
DASHED LINE INDICATING S.C. TO REMOVE (I) AXGK FOR FOOTING
I I .
NP
INSTALLATION.
5
q.
DASHED LINE INDICATING 6.0. TO REMOVE (I) HDL FOR FOOTING
S
_ _ _ I -
INSTALLATION.
r\ l
___
IS
_-----
--- S
_ ---
4 TYP.
1
---�—
ICJ
_-----
r _, -I
\
r _,
/
- -
F- - -1
- ---
-----
I 4P
I
E
L-----------------
— --- — — — — — — — — — — — — — —
— — — — — — — — — — — — — — — —
— — —
— — — — — —
— J
E
E
i
x xx-xx-xxx-
%
n %�-
SCALE: 1/4"
= 1'-01..
pQRTIQL LANDSCAPE
PLAN -
FACE TO FACE
ORTH
o' 2' 4'
8'
SCALE: 1/4" = I'-O"
5200 BUFFINGTON ROAD.
ATLANTA, GEORGIA 30349
(404) 765 - 8000
THESE PLANS AND SPECIFICATIONS, AS WELL AS
CHICK-FIL-A, INC. NAME AND LOGO, TRADEMARKS AND
DESIGNS ARE THE EXCLUSIVE PROPERTY OF
CHICK-FIL-A CORPORATION. ANY REPRODUCTION,
MODIFICATION, DISCLOSURE AND/OR USE OF
THESE MATERIALS (OR ANY PORTION OF THEM)
WITHOUT CHICK-FIL-ASS PRIOR WRITTEN CONSENT
IS STRICTLY PROHIBITED.
esencia
■
1743 E. McNair Drive, Suite 200
Tempe, Arizona 85283
Telephone 480-755-0959
V
H DA
v0
JEFFREY W. WRTMR
Lic. NO.015908
R$CHITBG�
08-02-2C21
Revision Schedule
Rev
Date
By
Description
r
r
N
N
Q
M 0
Q
Q
>
o
CM 0
w
J
J
z
i
Q
O
2
w
Q
0o
()
-0
Z
Z
U
Uco -0u
�o
a
Issue Date:
08-02-2021
Drawn By:
TP/GA
Job Number:
19060
Sheet Title:
Partial Landscape
Plan
Scale: As indicated
Sheet Number:
A-5
t.3
\
I
I
I
I
3 +D.4 ;0.7�tfftt
t.3
/ ;0 4 ;0 . 5 +1 . 0 +1 . 5 0 IlI� . 5
4,
t.3 OD-1 ETR
5 2 +1 . 5 +2 . 0 3 . 2 +6.2 +6.2 +3.3 +2 .2 +2 .2��
.3
m0 / .9 +3.4 +3 . 0 +3 . 7 +6.9 7�1� + .2 +4.5 +3.8 +3.7 4.3 .9 4
j 4 OD-1 ETR
+ *4
/ + *4
*6
*6
*4 + +70�
+0. 7 . 6 7 . 4.94 0 4.2 5.1 .4 +5.7 6.5 6.4 .5 6. 1 8. 9 8. 6. 1CID
4.9OG-1 ETR i OD- ETR.7 +9.9 4 F 8 +3.5 4.2 5.0 4 . . 5 . 9 .2 +7.4 7. 8 +6.7 +6. 9 +6. +6.9 +6.1
Cy b.4 II
/ +2.3 11 !7.5 3.9 +3.0 0 +3.4 4.0 7 3 4 . 8 +5.0 � . 0 +6. 8 � . 6 .9 +6.2 +5.8 5 �7
1'l.6 i
/ \ i + + + + 14. r r 14. r 14. r %-1 ETR I
2.2 ;5 . 1 � . 4 ;3 .5 2 . 9 2 . 9t*2 . 5 ;3 . 0 +3 . 9 4 . 0 +3 . 0 +3 .3 5 4 .7 4 . 1 5 4 .7 4 4 . 5____6_�
/
4 9
+7.2 .0
9 �.7
;1 3
+2 .3
+3 .5
14. # . 6
+3 .3
+2 . 9 3
4 . 0
4 . 1
+2 . 7
+2 . 8
# . 4
+3 . 8
4 . 9
*4. 5 +4 . 4 +4 . 4 1 3
� .1
+2 . 7
/0.8
\
1
6
+3.0
4 .
+6. 4 .
+3 8
+ . 8 .0
+5.2
4 . 1
+3.0
+3.3
4 .
� . 2
t7 0
+ . 7 .7 0 47.5
+8. 6� 8.0 +6 .
+3.6
+2.2
9
i
4.1
+6.3
i +8. 6 ; . 2
+5 6
. 4 7
+6.2
4 .2
+3.4
+3.5
4 .
+6.5
+8 5
.8 . 9 .8 +10 . 5
+8. 6 .2
+3.3
+1. 6
9
+1 . \+2��
9
+6.4
+9.8 3
+8 2
. 9 . 5
+6.7
4.3
+3.3
+3.2
4 .
+6. 8
+8 2
+ 0. 9 9 1 . 1 +11 . 6
tl . 9 7.3
+2.5
+1.2
t0.7
OG-2 ETF OG-2 ETR
+ 1.2 +5.0 6.6 10;\ ; ; ;\1 10.3 .8 0.4 .9 t7.0 4.2 +3.2 + + + 4 4 2.9 +3. 6.5 +8 0 0.9 10.0 10.6 10.9 t7.3 6. +3.1 +1.9 5
8 # . 1 + +6.2 +8.7 _+8 \ 2 i +6. 6 +10.0 +8 .5 +6.5 4 . 1 +2 . 9 +2 . 6 # . 4 +5.6 t7. 6 +8.2 +6. 0 +6. 9 +8.8 +6. 9 � . 0 +2.6 +1. 5
\ I 0
I
\ \ I
8 6 4.8 +6.5 Hato 6 \i 4. 6 16.8 !7. 8 .7 +3.5 +2 .3L . 0 +2 .7 4.0 .5 +4.7 +2. 9 *3.4 4 . 5 +1.9 +1.0
' 9 +2 +2 . 5 #3 . 1 + . 8 +6 . 1 +5 . 4 +4 . 4 0 +2 . 4 5 0 0 .7 +2 . +2 . 4 +2 . 1/_3nTQ 8 ++1. 2 +1. +5 .2 l 0 +5 .8 4. 3 +3 . +2 . 5 +1. +1.3 .3 .2 .1 .0 9 .9 +0. + 0�1+1.0+0.8 +1. 8.1 .2 �.7 *4 0 . ; +8 0.7 +0.6 t.5 t.s t.5 t
OG 1 ETR i a I
3 as I
\ +0. 6 +5.8 +3.9 t 3 +0. +0.3 5
r
O \ 1
+0 . +5.1 t7.5 +3.9 +0 II ; +0.4 +0.9
1�. 351,9 III I
-----
'i� 3 IrL 0 . 2 . 4
` ` .5 •4.B
O ♦`♦ lo.s 'li. L
3 • q 4 9 .
,
WL
9 tJI
• 3 ;0 . +1. 3 2.7 9 �., \ +2.41 L :+4 . +1.3
` � ;
a R.a S.7
3
6 -- - I ----- ---- -----J •.
7. i.9 1.3
L
\ �.34.I L L
*0\• 2 `♦ i ♦ .4 14.8 Sv(0
+0 . +0.6 1-! 1.9 0.3 0 2 0.2 0.2 0.2 9 +0.7
�• 1 i I
*0 .3 -0. + +0 1 +0.1 +0.1 +0.1 $ . t .4 +0.2 t .
III
� +0 . 1 � + +0.1 +0 . 1 +0 1 + . 1 t.1 +0 . 1 +0.1 +0.1 +0.1
m4
9.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 +0.0 0.0 0.0 0.0 0.0 0.0
O
+ + + + + + + + + + + + +
cn 0 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
z LO - -- -- -t. - -- -- - - --
SITE PHOTOMETRIC PLAN
2
IL
b.l
I
,
/
.1
Luminaire Schedule
Symbol
Qty
I Label
lArrangement
ILLF
IDescription
Mounting Hgtl
Lum. Lumens
•
6
L
SINGLE
1.000
CRUS SM-SC-LED-SPECIAL-30
9'-6"
1856
2
OG-2 ETR
BACK -BACK
1.000
GSM-XX-400-MH-XX-SL-FG-XX-X
20'-0"
21106
3
1 OG-1 ETR
I SINGLE
1 1.000
1 GSM-XX-400-MH-XX-SL-FG-XX-X
20'-011
121106
9
1 OD-1 ETR
ISINGLE
1 1.000
1 KSF2 400M R4W
20'-0"
1 22229
ETR=EXISTING TO REMAIN
Calculation Summary
Label
CalcType
lUnits
I Avg
I Max
I Min
I Av /Min
I Max/Min
Meal Delivery Canopy
Illuminance
Fc
5.70
7.9
1.8
3.17
9.39
Order Canopy
Illuminance
Fc
5.80
10.6
1.5
3.87
7.07
Property Line
Illuminance
1kc
10.41
12.9
10.0
1 N.A.
N.A.
Site
Illuminance
I Fc
13.90
122.3
10.0
1 N.A.
N.A.
3 -----.
II
EACH OUTDOOR LUMINAIRE EQUIPPED WITH A LAMP THAT EMITS 3,100 OR
MORE INITIAL LUMENS SHALL BE A FULL CUTOFF LUMINAIRE AND SHALL BE
ARRANGED OR SHIELDED TO REFLECT LIGHT AWAY FROM ADJOINING RESIDENTIAL
DISTRICTS AND AWAY FROM ADJACENT ROADS. THE SPILLOVER OF LIGHTING
FROM LUMINAIRES ONTO PUBLIC ROADS AND PROPERTY IN RESIDENTIAL OR RURAL
AREAS ZONING DISTRICTS SHALL NOT EXCEED ONE HALF FOOTCANDLE,
DrMIDG
Prepared 8Y: Date:
Project:
Type:
Scottsdale® Legacy (CRUS SM)
LED Surface Mount Canopy Luminaire
E N®■ (� IP66
I�
71�(kg)
a 5.000-22.000
38-152W)114 -156 QUICK LINKS
3204.5)
Odering Guitle Performance Photometrics Dimensions
FEATURES b SPECIFICATIONS
Construction
Electrical
Warranty
• Features a ultra -slim 11/16" profile die-cast
High performance factory programmable
• LSI LED fixtures carry a 5-year warranty
housing, with flat clear tempered glass lens
driver features over -voltage, under
(contact your LSI representative for
mounted to a the formed steel housing with
voltage, short-circuit and over temperature
extended warranty options.)
one conduit knockout and four mountingprotection
with Integral 6kV surge
p ere
Listings
holes. Unit is water-resistant, sealed and
protection that meets
s IEEE and
IP66 rated. Integral designed heat sink
ANSI C82.77-5 Location Category C Low
• UL and ETL listed t0 UL 1596. UL 8750
does not trap dirt and grime, ensuring cool
standards.
and other U.S. and International safety
running performance over the life of the
• Additional field replaceable TOW surge
standards. Suitable for wet locations.
fixture.
Protection device that meets a minimum
• Meets Buy American Act requirements.
• Standard color is white and is Finished
Category C Low operation r ANSI/IEEE
'y p (�IDA
compliant with 3000K or lower color
with LSI's DuraGrlp polyester powder coat
C62.41.2) is standard.
temperature.
process. DuraGrip withstands extreme
weather changes without cracking or
Driver components are fully encased in
DesignLights Consortium' (DLC) qualified
pealing.
potting for moisture resistance. Compiles
product. Not all versions of this product
p
with IEC and FCC standards. 0-10 V
may be DLC Please check the DLC
pressure
• Luminaire assembly her
dimming supplied standard with all drive
Products
OuallFletl Products List at www.designllghts.
to prevent
stabilizing vent breather to prevent seal
currents.
org/OPL to confirm which versions are
fatigue and failure.
Universal voltage power supply, 120-277
qualified.
Optical System
VAC, 50/60 HZ and 347-480 VAC, 50/60
• Features an array of select, mid -power, high
HZ input.
brightness, high efficiency LED: 3000K,
• -40-C to 55-C (-40-F to 131-F) ambient
4000K, 5000K color temperature, 80 CRI
operating temperature. (Varies based on
(nominal).
lumen eand mounting
gsstyle see
• Choice of Symmetric or Asymmetric
performance fo
distribution. Asymmetric provides a wider
Minimum 60,000 to 100.000 hours
distribution pattern.
depending upon the ambient temperature
• Six Lumen Packages: 10,000,
of the Installation location (see
13,000, 18,000 and 22,000 Lumens.
,000 Lumens.
performance data for specifics.)
Be Induehtu Inc. 10000 Alliance Rdu . Cinnnati, OH 45242 • www.ld-indEmtriesmm Nice 1/4 Rev. 09/22/20
(513) 372-3200 • 02020 LSI Industries Inc. All Rights Reserved. Specifications subject W change without notice. sPEp.1MaA.9820
Type:
Scottsdale® Legacy LED Surface Mount Canopy Luminaire
ORDERING GUIDE Bank to Onink Links
7yPlcuosPER D:aMPLE: CRUS SM SC LED VHO 50 UNV WHT
Plela OleHibuti n LIgt Souls
�.
gdw NMm
Color Temperature Input Volupa Finish options
CRm BM
8C-Standartl Symmetric
LEO
SLW-Super Lea Watt
50 NOOK
UNV Unishad vaHape (120
WM Wnite
OFL OiXuseO Len
(NomeceMOIEM1i
W.W-Very taw Wan
40 40WK
2)7V)
Nm - Brame
AC.Asymmenic'
LW.LMWW
30-30WK
ILK -Black
SS -Super Saver
347 MVBI1
NO - High Output
WM-Very High OuoN
PoOTriOTEu:
1. AC tllRrmmlm u[Illma a relleUor which afters Inc ICW from a afeMer[I SC W[rlLuliM
Accessory Ordering Infermatlen
Onwptbn Odm MemMr
MYWope Surlem Atlepl9r MI52CUR
1PT[ryY qnM Han
gar Min
PERFORMANCE
O
5200 Buffington Rd.
Atlanta Georgia,
30349-2998
Revisions:
Mark Date By
0
0
THIS DOCUMENT IS NOT
FOR REGULATORY
APPROVAL, PERMITTING,
OR CONSTRUCTION.
ARCHITECTURE
ENGINEERING
INTERIOR DESIGN
PROJECT MANAGEMENT
604 COURTLAND STREET
SU8E100
ORLANDO, FLORIDA 32804
PH 407.645.5008
FX 407.629.9124
STORE
CANOPY ROLLOUT
PROGRAM FSU 31
1626 RICHMOND RD
CHARLOTTESVILLE,
VA 22911
Back m Ouch, L'nks SHEET TITLE
MM ED LUMMS
mum
MMK=
MMK her
IYnYn Pods
plaWhmkn
MllmeWMm
mlmm
sue canoe
0ellmne Wmam
Bmnm
eU9BYRp
ullE.eeWMna
maser
IN Rmlm
WdmP
5G
21301
1N
1W0.G2
21835
14
"AH 62
um
led
84 W-02
,
VHe
eL
17M
114
Games
mien
117
B3UPG3
Im
in
MMG3
1
17BM
in
83e"1
1"
14
BaUPG2
19m1
1M
dlkt)] 2
flat
14M9
116
M UOe2
149%
119
B9U9G2
15548
124
NinG2
in
inAG
SG
13113
141
n uo in
13449
144
BNMI
13M1
IN
ls M GI
PL
need
in
03-WG2
11m1
1M
B9UOG2
12221
131
M M M
so
loan
1"
e1
10M
1N
113 1
1110
154
B9{VG1
PC
910
1m
M JOa2
9379
in
BYUDG2
970
IN
MU3G2
m
CC
97N
14
B9 UO G1
9N8
119
B0.Uoa1
am
1N
o3wel
Ww
nG
7M1
1z1
MLo G1
7MB
191
BAUPGI
B1M
IN
di
W
SC
Nls
1M
M-U0.G1
5M9
1N
BAUCGt
else
IN
M- I
SW
PC
4BM
1'tl
B1-UM1
Sap
let
B1 U9G1
52M
1N
B1ipU1
N
•LEDs are npwlRly unaa[a] tneNare ♦alw ue ncmlml.
EIECIRIMUTA(AMPS)
Lunen
Finds'.
WoRce.
into
Eery
sectorzm
eons
Ne'1
we
that
ix
On
a.e4
am
0.4
adz
Ho
124
1.M
a.s
am
am
am
ON
as
92
a.n
a.a4
ode
a.33
0.27
0.19
IIN
72
as
ass
0.3
0..0
OM
0.15
v(w
00.5
0.3
0.5
am
0.17
0.13
SUN
3e
On
0.18
0.16
0..14
0.11
ON
•Blec[dal dam m Esc m0. Acmal cans W 9e mm� eiae. M+/-30%
OPERATINGTE !7RE
WYN"41E9E
MumYl
Y
va0
Maw79ea CWW
ac
He
k1ndVAbee Cdnop)
450
in
nekW.bW pnGP,
me
Recommended Lumen
Malmen..W MUG SM NO
,UbMN➢mPC
Inmtl=
Mon.
Nk he
mknr
lam nr•
a
102%
M%
M%
M%
84%
too
102%
97%
M%
Si
84%
MC
tat%
M%
M%
M%
84%
no
102%
9716
92%
N%
N%
we
less
97%
0%
N%
84%Me
101%
95%
90%
N%
N%
WC
101%
N%
Mx
M%
78%
Recommended Lumen
WIh%de W CRUS SM RS
Mniemachi
ldual=
III
SMnr-
Mi
ION or
0c
102%
Mx
in
N%
Nx
too
102%
97%
M%
We
Nx
20C
1M%
m%
M%
89%
94%
25C
102%
M%
92%
e8%
sw
MC
Im
W%
92%
N%
84%
no
102%
97%
M%
M%
N%
soc
101%
0%
91%
Nx
Mx
F90RN 0:
wM 1-men malrnancevaluesat2s'cm®IalrtM �er rMn Yusea an (M20 data and in-olW time
du re teatln9.
2-In aeWra"KBMIM1 IRNRTM-21-11, RpIMBj VgU3Anre56n[InpnMb[nd wire want nn tlmn du2[Inn Wf eRMHn Y[ IMo(6%)Ca IFSNR 1M-BPIeb61 bEtaYAtkn(h M1OYR) krCyarA:.O
Yna hR9q WthiO ere pxY-11.(El)).
3-In etmldxvs Mtn IESNAIM-]3-11, Ublals] Nlues rgnaent time aunNalu IN[exwM 5x tlmaz NA (M-BaLa tnbl bctdura[kn(F Hours) fortle MMeuMvfsHn9 (WT) la. tnerYr4amed Lm).
VERSION: V7.025
ISSUE DATE: 11-2020
Job No. : 20.0979 ,
ot
Store :3187 g
Date : 11.2020 w
to
ot
Drawn By BIA
Checked By: GAF
w
Sheet
SITE PHOTOMETRIC PLAN
f�
c,
ES=l00 x
U
LSI Industries Inc 10000 Alliance Rd. Cincinnati, OH 4524E • wwwld-I1,dM[rlescom Pogo V4 rsay. M/22710
(513) 31. 02020 LSI Industries Inc. All Rights Reserved. specifications subject to change without notice. SMC.1M4.A.Mm
.0 0.0 0.0 0.0 0.1 0.2 0. 6 10.5 10.6 10.5 10.3 10.2 10.2 '0.1 '0.1 '0.3 '0.2 0.2 10.3 10.2 10.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0
.0 0.0 0.0 0f� 0.0 0.0 0.0 0.1 9 +1.0 0.8 0.8 .5 0.3 0.2 0.3 0.5 0.5 0.6 0.6 0.5 0.4 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0
.0 0.0 .0 �-O 0.0 0 0.0 0.1 .4 0.8 +1.1 +1.3 *2.2 9 0.7 0.5 0.8 +1.0 0.9 0.8 0.8 0.4 0.2 -t _ 'D.0 0.0 0.0 0.0 0.0 0.0 0.0
0 0. 0.5 +1.0 2.2 2.4 2.3 +4.2 `3.4�`L 8 1.3 1.0 +1.4 +1.4 +1.3 1.4 0.7 0.3 -- 0.1 0.1 0.0 0.0 0.0 0.0 0.0'
.0 0.0 0.0 ' 0.0 .5 $.9 +4.4 °3.+ +1.6 '29�.2 °3.0 +1.9 1.3 0. 0.4 10.2 0.1 �0 0.0 0.0 0.0 0.0'
W ` OR _
0 O.c� 0.0 0.0 0.0' 0.0 0. 0 `2.8 R.PAD 1.0 $.4 +4.5 22.9 - ' 6_ '2.0 0.6 0.3 0.2 0.1 0.0
.0 40 0 0.0 0.� 0.0 0.1 0 .7 .2 .9 $.6 < jQ '10.1 $.0 t.9 3.6 '8.3 4.2 2.8 `3.1 2.5 .6 +1.0 0. 0.1 0.1 0.1 0.0 0.0
\ o
OD1 I - _
.0 Q.0 0 0.0 0 0.0 0.1 0.5 4. 14.2 7.0 *10.7 7.6 $.1 $.0 $.8 '§.2 *10.9 7 7 `4.2 `2.7F +1.6 I1.0 .3 0. 0.1 $ t r-I 'G.
I OD1 [3)I
EX. PER °
.0 a'TO0 0 0.0 0.0 0.1 +1.3 $. $. *10.0 .5 'b.O 79.9 t.9 �9.1 10.0 )2.6 1 7.0 `4.5 `4 2.8 �.8 +1.0 0.6 0.3 0.1 0.1 0.0
I EX 30'
• \ ° � EA EM h
.02 0. 0.0 \ 0.0 ' 0.1 0.1 0 � $.9 $.8 7.9 $. 7. 1J 19 1 )2.'10.3 '8.2 .2 $.7 $.6 I +4. 2.7 +1.3 0.6 0.3 0.2 0.1 194'
,� � I OH250J
( I 0.0 0.\1 I 0.1 10.2 .6 7.7 $.1 $.4 $.5 .8 O D 1 '8.110.6 *10.3 18. 18.7 79.1 $. 9 �I �0 10.7 I7. I 1.6 0.7 0.4 0.0
o � �
a0 .0 0.0 0.1 \ 0.2 0.4 1.0 %.7 '5.5 $.6 14.5 t.3 .2 .4 4.4 4.5 $.8 $.9 $.7 $.1 7.3 75.1 15.2 $.3 < 161 �.0 +a.1 1." 7' t. I1 0.0
\ 1 I
.0 .0 0.1 1 0`� 0.5 1.3 2. .1 3.9 4.9 '4.0 3.6 12.9 `4.0 `4.9 .5 7 4.3 $.2 $.0 $.1 $.7 4.8 4.9 7.8 .4 '8I4 +4.3 .9 0 0. .2 0.1 0.0
.0 0.0 0.1 + .1 0.3 \ .6 2.7 .0 3.5 3.6 *3 2 .2 `4.7 `4.4 "3.5 `4. 4. $.2 .9 $.0 7.2 19.4 $.9 ,3 0. 0.4 .2 1 qI.0.0
IEX. 15 Co�pCO
0.8.1181, PG.282
.0 0.0 0.1 0.2 0.4 0.8 .7 3.5 %.2 3.8 `4I t.9 .9 .3 t.1 *3.4 73.4 `4.5 14 9 .6 $.9 $.8 'b.9 4 +4.2I 2.3 0. 0.4 0.2 I0.1 0.0
0 0.0 0.12 0.4 0.9 "1.8 `4.1 $.0 $.7 .0 '86 3 4 1 7 6 7 �J $.3 7.5 7.6 `4. 3.1 I +1.5 .9 0 0. 0.1 I0.1 0.0
\� I I
0 p 0.1 0.2\ 0. 0. `4.6 $.6 $.8 1.
8 0 0 `4.2 "1.3 *1.2 *3.4 $. 7.8 "8.1 7.0 $.4 1.8 I +1.1 0.� 3 000 .1 1.0 .0
- -� G2 G2 I I
.0 0 \0.1 0.2 \.4 0.8 `4.0 $.8 $.5 7.1 $.4 $.8 $.3 $.3 3.8 2.2 2.0 3.1 $.5 $.0 $.6 7.4 7.0 $.2 .7 +1.4 0. 0.4I 0.2 0.0 10.0 0.0
I
.0 *1 0.2 0.� .7 3.1 .8 3.5 4.2 4.4 '4.1 3.9 4.8 3.3 2.0 *1.7 2.5 3.9 3.0 3.0 3.3 3.4 73 2.2 +1.0 .5 0. 0.1 .1 0.0 I 0.0 0.0
.0 0.0 0.1\ \ 0.1 0.3 \ \0.5 1.0 71.8 '2.5 2.9 - 3.6 3. 3. %3. t �.6 .9 �1.7 '1 9 +1.8 .4 0.7 0la .2 II 0 1 0.1 0. I 0.0 '0.0
W
.0 0.0 1 1 0.2 .7 2. 13. t. 14. *3. t2.5 '2.0 7 .8 7 .3 .2 .2 1 t 9 +1. 1.2 0.2 0.0 0 I 0.0 %.0
I W
0 0.0 0.0 0.1\ 0 0.3 \ \ .4 0.6 0.7 2. .6 0� 4.2 4.0 5 0 1 '0 8 0.8 0.9 0.8 0.8 0. .4 .2 0.1
4
0.0 0.0 1 0.2 16. 3 0.5 3. 1 7.1 $.3 OJ OJ OJ 0 0 7 71 9 +1 1 +1 6 +1 7 .3 .1 '0 0.0 a 0 Oh
OH Imm
EX VAR.WIOTH ACCESS
EASEMENT
.0 D.B. PG. � s72 0.0 0.1 0.1 0.1 0.2 0.3 $. 75. 3 $.4 OJ OH e 0 , 3.1 +1.9 .3 3.5 .3 I +1 0. 0.0 0.0
\ \ OH(TYP) I
0.0 0.0 \0.1 0.1 0�1 1. 1 OL 01 J +4.3 2.8 +4.5 '5.7 2.9 1 0.2 0.1 0.0
1
.0 0.0 0.0 O.P\\ '0.1 'O.1\ 10.2 10.8 .4 1. 2. OL OJ %.6 2 +4. +10.0 $.9 +1.7 0. II 0.1 0 0.
\ \
.0 0.0 .0 0.0 0.0 \0.0 0.0 b.1 0. 0. 'b.9 "I "3. *1.4 OJ 2.6 .4 +16.2 2.5 0.8 r4 0. 10.1 ' .0 0.0
\ 0'D. I 0 I
0000
.0 p�.01\ 0. 0$ 2720 .4 .4 'I.3 .1 O J OA %3. +1.8 ° .2 . +1.4 .8 2 I.1 I.0 .0 .
EX.' .0T POLE0. .0 0.0 0.0 0.6
\ / L- OJ OG3 I I
e e
.0 0.0 0.0 0.0 0.0 0.0 0.0 \00.0 $.1 0. 0. $ .6 a 3.8 .�0 ?98.5 $.7 .9 3.9 3.1 2.1 10.2 15.8 +1 +1.2 0.6 .2 �-i 10.0 0.0 '0
\\ \ H( p) e 0 I
0 0.0 0.0 0.0 .0 0.0 j -i10 \ 0.0 0. \ 0.1 0.1 ?7.8 .5 2.6 0 .2 %.3 1 0 1.3 2.9 $.6 7.9 0. 0.3 0. '0 1 10.0 0.0 0.0
� e
0 0.0 0.0 0'0- .0 0.0 0.0 0.0 �.0 0.0 \0.0 0. 0.1 i).7 4A. . 8.4 3.3 .3 0.3 0.3 0.4 0.6 2. 15 $.4 0. 0.2 0.1 0.�1 0.0 0.0 0.0
0 0 15 CENTEL CAS£
D.B. 1132, PG. 109
/ \ (S.H.F..B. X1,, PG. 1 4 _
0.0 0.0 0.0 0.0 0 0.0, 0:0- 0 0.0 O.tQ 0. 0.1 0.2 0.3 1.8 0.3 0.2 0.1 0.2 0.2 0.3 1 D.82.538, Pa44 - 69 .5 +1 1 0.3 �.0 .0 0.0 0 0
/ 7 �
0 0.0 0.0/- V O .0 C:�-QF EX, IPA, TELE+0.O \ 0.0 0 0.0 0.1 0.1 0.3 0.7 0.9 IDA 0.1 0.1 0.1 0.1 0.2 .3 +1.4 2. 8- 0.2 .1 0.0 I 0 0.0 0.0
\ & TGPH. CO. ESML EX 19' CENTRAL TELE CO. EASEMENT
D.H. 530, PG. 293 \ �X.SPPER 7C D.B. 1135, PG. 60 & 66
0.0 0.0 0.0 0.0 �. 0.0 0.0/00� 0 0.co. 0.0 0.0 0.1 0.1 0.1 .1 .1 .1 0.1 .2 .3 0.6 .7 0� _ aE--o 0 0�0_
I \ C L OF EX 10' 2A EX. 15 CENTEL ESMT.
THE & TGPH. CO ESMT. 1 1132, PG 109
O.B. D.1B PG p467n-469
0 0.0 0.0 0.0 0.0° 0. 0 0.0 0.0 0� 0.0 0.0 0.0 0.0 0.0 �0460, Pb.67 0.0 0.0 0.0 0.0 0.0 Xl, WYID4) .1 0.1 0.2 .3 0.3 1 2 0.1 0.0 0.0 0.0
fPE
f_X 7
.0 0.0 o.0 81i.0 o.0 .0 0.0 0.0 0 0.0 �+G�Q 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 '0.0 '0.0 '0.0 .1 0.1 .0 0.0 0.0 0.0 0.0 0.0 0.0
7(
0
PROD L 0.0 0. 0.0 0.0 .0 0.0 0.0 +D0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 b.0 0.0 ELOE oo 0
05, RW-201)
F -_____
RICHMOND ROAD - STATE ROUTE 250
PHOTOMETRIC PLAN
SCALE: 1 "=20'-O"
SITE LIGHTING FIXTURE (LUMINAIRE) SCHEDULE - CHICK-FIL-A
MARK
QTY
SYMBOL
MANUFACTURER
CATALOG NUMBER
NO. LAMPS/TYPE
SYL LAMP NO.
LUMENS
WATTS
VOLTS
MOUNTING HEIGHT
LLF
OD1
4
•❑>
LITHONIA
KSF2-40OM-R4W-TB-SCWA-SP09-DBL-LPI
1-M400/PS/U/BT28
64320
38,000 EA
456 EA
120
20'
1
* OG1
2
• ❑>
LITHONIA
KSF2-40OM-R4SC-TB-SCWA-SP09-DBL-LPI
1-M400/PS/U/BT28
64320
38,000 EA
456 EA
120
20'
1
* OG2
2
<❑ • ❑>
LITHONIA
KSF2-400M-R4SC-TB-SCWA-SP09-DBL-LPI
1-M400/PS/U/BT28
64320
38,000 EA
456 EA
120
20'
1
* OG3
1
° ❑>
LITHONIA
KSF2-40OM-R3-TB-SCWA-SP09-HS-DBL-LPI
1-M400/PS/U/BT28
64320
38,000 EA
456 EA
120
20'
1
* OA
1
B
SECURITY
RWSC-50PMH-FT-BK-120
1-MP50/U/MED
64587
3,450
72
120
1315"
1
OH
42
e
COOPER
RL460WH83OPK (PROVIDED WITH CANOPY
PACKAGE)
INTERGRAL
N/A
600
10.5
120
9141, / 11'4"
1
* OJ
10
B
SECURITY
RWSC-50PMH-WD-BK-120
1-MP50/U/MED
64587
3,450
72
120
13'5"
1
* OL
2
e
ECLIPSE
TY20-WM-LEDD-3K-120-ED-BK-ARM6-WET
INTERGRAL
N/A
N/A
25
120
14'
1
POLE FIXTURE SCHEDULE
MARK
QTY
MANUFACTURER
CATALOG NUMBER
ANCHOR BOLT SET
POLE BASE HEIGHT
OPTIONS
*OG/OD
9
1
1 LITHONIA
I SSS-18-4C-DM19/DM28-DBL
ABSSS-4C
2'
NOTES:
1. DRILL MOUNT THE ARMS/BRACKETS FOR THE LUMINAIRES TO THE POLES.
2. NOT USED
* 3. THE ASTERIK (*) BESIDE THE FIXTURE MARK IN THE ABOVE SCHEDULE INDICATES THE FIXTURE IS A NON -PROTOTYPICAL LIGHT FIXTURE PER THE CFA NATIONAL PROTOTYPE.
STATISTICS
Description
Symbol Avg Max Min Max/Min Avg/Min
Calc Zone
+ 1.8 fc 19.2 fc 0.0 fc N / A N / A
Parking Lot Summary
� 5.3 fc 19.2 fc 0.4 fc 48.0:1 13.3:1
U
EACH OUTDOOR LUMINAIRE EQUIPPED WITH A LAMP THAT EMITS 3,000 OR
MORE INITIAL LUMENS SHALL BE A FULL CUTOFF LUMINAIRE AND SHALL BE
ARRANGED OR SHIELDED TO REFLECT LIGHT AWAY FROM ADJOINING
RESIDENTIAL DISTRICTS AND AWAY FROM ADJACENT ROADS. THE SPILLOVER OF
LIGHTING FROM LUMINAIRES ONTO PUBLIC ROADS AND PROPERTY IN RESIDENTIAL
OR RURAL ZONING DISTRICTS SHALL NOT EXCEED ONE HALF FOOTCANDLE.
W
I
FULL CUT OFF
LIGHT FIXTURE
OR OF POLES AND FIXTURES
LL BE BLACK
U E TRAIGHT
0
2' CONCRETE POLE BA
FINISHED GRADE-,
SITE LIGHTING POLE
NOT TO SCALE
20'
SEE LUMINAIRE SCHEDULE
THIS PAGE FOR POLE
MODEL NUMBER
DAi
J
z
O
LU
z
LU
LU
LL
LU
O
LL
0
Uj
rn
coo/
o
D° o o D D o 0
0
5200 Buffington Rd.
Atlanta Georgia,
30349-2998
Mark Date By
4 12-8-14
CIVIL COORD.
Mark Date By
Mark Date By
Mark Date By
Mark Date By
Mark Date By
Mark Date By
Kurzynske & Associates
ONSULTING ENGINEERS
825 Third Avenue, South
Nashville, Tennessee 37210
Telephone: (615) 255-5203
Fax: (615) 255-5207
Email: mail@kurzynske.com
STORE
Pantops FSU
S08A
Pantops Drive
Charlottesville, VA
SHEET TITLE
Photometric
Plan
VERSION: V9.1
ISSUE DATE: 8-2013
Job No. CF1352
Store 31# 87
Date 2/24/14
Drawn By : BTS
Checked By: MTK
Sheet
ESEI
0 10 20 30 40 `[/V
IA L/THON/Awill
L/GHT/NG®
Nm
FEATURES & SPECIFICATIONS
INENDED USE -Ideal for at lot, meet lighting or parking areal ype
CDNSTRUOION- Rugged.063" thick,aluminum l lineathouO4 Formed forwmher-Ug col and
integrity. Naturally anodized, eatmdad aluminum door fame with mitered comes, is maimd with two
O .1M" diameter hinge pins and soured with one proper- cum, qulckHelNse fa .. NkmheNmofsul Area Lighting
between homing and door fame is accomplished with an Integrally designed, extruded silkone gasket
that snaps into the door fame, and another gasket applied to the housing KS F 2
no h:Standard finbh is dad bronze(Di mlyener powder finish wihother auhN lmlorswalabk.
OPflCS - Reflectors are anodized and segmented for superior und6 mjy and coined. RdenOrs aeath
with used Am brteners and are rotatable and Imeklangeade. Five rotor behlbutlons available: Type II
a 111(asymmetdd,Type IV (forward threw, shop cotorlType IV (wide, forward thmw),Type METAL HALIDE: 25040DW
V (sguare), is.125"thick impart-mostant tempered glass vdth thmmllyapplied silk-scnened shield.
Roger for 250sooW. Super CWA pulse -sup ballmt HIGH PRESSURE $ODIUM'20O40DW
CWA (pulse start ballad), MH efficient and EISA
end for U.S. shipments ony,l3A or INTL required
mountingsavailable.
swifimtIom
FAA, 2.0fir (A mq
Ordudmarel
Length: 24-19/32 (623)
Mi 17-25M (62.5)
Depth:8-5116 Di
Arm:4aD2)
•Weighb521k D3.61g)
'Weight as cmfigured in mmple brim:.
All immune are iMhes(mnme n)units
gtherwMspxMed.
15'to 25' Mounting
II�
FArm� L
Moumina omlon MIIImmmDAM
SPax, RPxx, DA12P 5
Were, DA12WB 6
WWaa 7
KSF2
Seeks
Wattage
Dmdbution
Volkge
is t
Mounting
KSF2
MesaLIHImd
R2
Typellmadway
12D 347
an neck
An lend
Shippedm
N
2SOM' 350Mea'
A3
Typelllasymmem,
2ggr 4W
no
arepole
M 4"am
DA12P Degmeambpole
Nil 4DOW
R45C
Type IV forward
240' TB'
aM
Rou ale
lab Sara
M12W8 DegreeamNwall
High pressure
throw, sharpcutofl
thenforwashhruw
Y77 2305MM'
-,_.r.
M 9'am
KMA Mrtamatlapmrsodium
MW
HWA Supee pu se-
12"
DMB TWlnmmandal
nting ban
2003 4005
surtballast
PWBIbw
155
T V me
YR
2505
X01EkrsM1lmemmLLSmmarM,
SLlyammbespLdfxdmmhmN
xNOEM
0
Vd
Shiocedlnstalledlnfixture
EC EmergenryermU"
S1Mpedich,
(blank) Dadbronze
rosi
11
m
PER
NWAtwig-lakrecepude
GA CSACertlfietl
PET NF)AAM&4akH(12b2Bk24OV)
DWH
White
r 'tan 's
m ed
only (no photaontre0
MOM NOMCenlfied
PB NEMA team lack PE(3471
DBL
Black
CRT
Na A
silk
SF
Single Nu(120,T2, 347Y)
INTL Availablefor MHproba-mn
PE4 NEMAtMSt-Ink PE(4BOV)
DMB
Medium
irl
satin lu
9
Sa70'
shipping outside U.S.
pE7 NEtMtwist -Ink PE(2PV)
brena
N
DoublefM(M,240,48W)
•
MI Kit offill 12W control relay°
5C Sh dAggupmrPERopdon
DM
Natural
BRIE
014 Miawlaah• 277V control retry°
XS NousesdeshlNd (R2,R3) yp
aluminum
NIOHm
MEhas
0M
0uam resmHsymm"
REGC1 CalitomlarlM20efRUve
VG Vandal gourds
..-e w:=.vw,.
URSTD
gRSgmedeW'
1/1/2010
.hN,wadm•asr
s: Tenon Mounting Sllpfitter
Numbuoffimms.
2-3/ri Thin Tri 120,290 7&32D TNH9O T %
2-7W(73) nel 115-280 T25-290 125320 MHSO M4%
V ORly Ti In Me Tls-291, 135-320 Tell Tel
OUTDOOR
NrM
arilliiyryttem.
I(afxhAbffiavmh�hw.t2MMilhmbdlkhHA'a4m. 1p MUSthrernyvoltage.XolrvailexewiNln
2 UX .Ajadeted lamp. 11 Mnlmumallnwablewanagelampintlukl
R plaWaMtannaharearalnbleanl wXh]SOSwemS
3 MunbearMMwnA S(WA.
4 lAwewmagesanotmmpywla Glllomh101e2art9alalbM 13 Mra"X MOMF2An MMW
s Naearannbl<wimscwA M vreA,MmuOwnawemmmmawaray.
6 Remoperily GVIcamsein unada. 15 AnikxewhM1mandmtlAMbPSonsmN.
7 Optional mull) -lap ballast 120,208, 2W,27ALRN,27/, 16 Sexwwarwom"Yatl"°bnk"dN°'4m°'°p°c
347Vin(anada). R mawbmN.
8 (amdthnwylorwailadlewmagw is Naatkape w.
9 Uw9'amnfmtwo armor, lommoneareanentMonaw 19 M h. Mwm12
KSF2-M-S
MFR SPECS FOR FIXTURE "06"
OD1: KSF2-40OM-R4W-TB-SCWA-SP09-DBL-LP1
OG1: KSF2-40OM-R4SC-TB-SCWA-SP09-DBL-LP1
OG2: KSF2-40OM-R4SC-TB-SCWA-SP09-DBL-LP1
OG3: KSF2-40OM-R3-TB-SCWA-SP09-HS-DBL-LP1
HALO
DESCRIPTION
The Halo RL4 series is a retroft LED Baffle -Trim Module for 4"
aperture recessed downlights. The RL4 is designed for use with
compatible 4" housings. The RL4 integral LED driver is dimmable
at 120 volts. The RL4 lens provides uniform illumination and wet
location listing. The RL4 die-cast construction makes any housing
AIR-TITE for added HVAC savings and code compliance. I i;;__
SfCa41rIa4e IIVw Insider. alaCS
MECHANICAL
ELECTRICAL
Warranty
Module -Trim
Power Connections
Cooper Lighting provides a five
• Module construction includes
• LED connector is a non -screw
year limited warranty on the RL4LED,
heat sink, reflector, lens,
base luminaire disconnect
LED.
baffle and trim ring
offering easy installation with
COMPLIANCE
ORL460WHt
•Durable die-cast aluminum
the matching Halo H995 Series
Labels
construction
• Regressed ba(fla
housings.
•LED Connectormeets California
• UUCUL Listed 1598 Luminaire
Heat sink desi ned to conduct
9
Titla24 high-efficacyluminaire
(with listed housings)
heatawayfrom the LED
requirement for a non -screw
mUUCUL Listed for Damp
Location
keeping the junction
base socket, and where
• UL/cUL Listed for Went
temperatures specified
P P
required to rail as e
Q quality
Location - Shower Applications
APP
White
evelows
maximums even when
hi h-effica luminance.
9 cy
• ay Ingrain Protection rated
9
installed in insulated cailin 9
• The included medium
• Maybe installedin housings
environments
• finish options
n adapter
screw -base Edison
in direct contact with
- Makes White paint finish lWHl
provides easy retrofit of
'e
permeable insulation"" and
- Satin Nickel plated fhnish(SN)
incandescent housings lSee
constructible materiel
Housing Compatibility).
Lent
Ground Connection
ReGNan
In
• Regressed lens
• Separate grounding cable
-EN
.ENERGY STAR®qualified
• Impact -resistant polycarbonate
included on the RL4 module
residential and commercial•
. Can be used for State of
•Convex form for lamp -like
farattachment to the housing
CaliforniaTitle24 high efficacy
appearance
• High lumen transmission
duringinstallation.
luminaire compliance"
• Diffusing for even illumination
LED Driver
• Can be used far Washington
State Energy Code
RL460SNt
MOUNTING
• Dimmable driver isa120Volt,
(WSEC)
Friction Blades
high efficiency, electronic
and International Energy
Satin Nickel
power supply providing DC
Conservation Code
• Precision formed spring blades
power to the LED.
(IECC) high efficacy, luminaire
90CR1
secure module to compatible
• Driver memo FCC EMI/RFI
compliance
2700K, 3000K and 3500K
housings.
Consumer Level limits for use
IC and AIR-TrrEI"
90CRI
• Friction blade design allows
in residential and commercial
er
Certified under
the RL4 To be installed in any
installations.
1598 598 with it
and listed UUCUL w
2700K, 3000K and 3500K
position within the housing
aperture (360 degrees).
. Driverfeatures high power
compatible housings, may
4-Inch LED
Housing Compatibility
factor, and
integral thermal protection in
be used to most insulated
ceiling'*and restricted air -flaw
Recessed Retrofit
See Housing Compatibility
the event of over Temperatures
P
requirements Such as:
Module -Trim
section.
or internal failure.
• Washington State Energy
LED
• Driver mounts externally to
Code (W9ED)
• ColcrTemperature(CCT)t
the module, allowing future
• International Energy
replacement, if needed.
Conservation Code(IECC)
FOR USE IN
Options: 270013000K, and
3500K
Dimming
• New York State Energy
INSULATED CEILING
as Color Rendering Ind"(CRI)t
• The Halo RL4 LED is designed
Conservation Construction
AND NON -INSULATED
Options: 80 and 90
for dimming capability to
Code(NY-ECCC)
• State of California Title 24
CEILING RATED
• LED is chip on board design
g
10% In normal operation
with standard 120V LED -Rated,
"Recessed Luminaires in
HOUSINGS
consisting of a multiple LED
i
package with proximity
electronic low voltage, and
Insulated Ceilings."
phosphor coating to create
many incandescent dimmers.
HIGH EFFICACY LED
one virtual white light
The LED module may also
WITH INTEGRAL
source for a productive
dim to 5%nominal using
DRIVER -DIMMABLE
'cone of light"
dimmers with low and trim
adjustment, (Consult dimmer
manufacturer for dimmer
details. Note, some dimmers
m
require a neutral in the wallboal
® 2•'�
311110K-
•kxmlMW"CWOieRR WENERGY
arAAa DUMiXea Pmtlwb Lsw ard CEc (1zq
A1xNimwa Deta17e90 mrliepme.
•°"
ail
d
ADV131345
000
COOPER LightingT
NOforueewiMhoUel slndirectcon whhspreyfoaminsulaton.
"See orde ring lnformMlon tablefor evelleble models.
NovemNrl5,Ml310:57AM
IA
mlb'
L/THON/A L/GHT/NG-Ca
N umber
-
Nato
FEATURES & SPECIFICATIONS
INTENDED USE- Sgmremaight Steel pole for up m 39-foot mounting height
Type
OKSTMCTION-Weldable-grade,hstmolled, mmmerdal-qualirycaton steel cubing with a minimum
d of 55000 d ll- aue or 50000 d(7-gauge). Uniform wall thickness i 196"or,1793.Shaft
1 9 9h
is meykre with 'cull -length longitudinal high-fequenry elMdc resirtanu wild. Uniformly square in
ao t a
cross-sMlon with flat sides, small comer radii and euNlent torsional qualities. Available shah widths are
Anchor Base Poles
4, 5 and 6 Wm
Andu base B fabiaWfan bar ruled urban sled plate uniforming to ASTM AU, that nweo or eimcedsa
minimum -yield straight of 36,000 psi. Base plate and shah are dock mferemlally welded cop and bottom.
c
Chedto
Base mwv In match pole.
S
A hal le hawing Nominal dimemlonsof3" x5"for all shahs. Included is a aver with amchment screws.
art/ art/
To is cap provMed With all di man and open top "PP poles
Fasteners are high -strength galvanized, zinc plated or minless met.
SQUARE STRAIGHT STEEL
Finish: Must specify finish.
Grounding: Provision routed iormedla" Inside handhole RD, Grounding hardware Is not included
(provided by others).
Andwbdo:Toppmion ofanchork1tb galvanized Fall A-153. Madeofinel and having a minimum
yfddMngthc55MOpsL
Noe. Spedfiabons subject No change without mice.
Actual pecomone may deter AS a result of end user training ment and a pplication.
Lead dries will vary depending on opl wledetl. Consult with your a lei representative.
Example: SS$ 20 5C DM19 DOB
sss
Nominal fixture
Nominal shaftbase
Series
mounting height
siza/wall thickness
Mounting'
options
SmndarAmlors
Ss5
10-39 feet
(See back page)
Tenon mounting AERIS^Suspend drill
Shipped installed
(See bad page.)
or
Open top (iIcluster
! 'p nln `'
UAB
Less anchor bola
DDB
Darkbmnu
cop cap) ':'
DM19AST_
tat 90"
VD
Vibration damper
DWH
White
T20
2-3M"0.0.(2"NPS)
DM2WT_
29180o
TP
Tamperproof
DBL
Black
T25
2-7/8"OR(2-1/2"NPS( I.
DM29ASi_
2a490'
H7-ldi
Hodzonul arm bracket
DMB
Medium bronze
T30
3-1/2' O.D. D"NPS)
DM39AST_
3at90-
pfihturel
DNA
Namml aluminum
T35
4"O.D.(3-112"NIPS) ".
DM49AST_
4at9O
Mom
Festoon ou0etless
pgsskmlars
drill
Necbkap
Drill mountlna'
DM19
tat 90' ".
OMERO^Suspend
mountin '
CPL1Bv
1R"mupling'
p35
Sandstone
DM28
tat 10°
DM19MD_
tat90-
(PU4u
3W coughig'
DGC
Channel gray
DM78R
2at1801 gnesltle "i
DM28MD_
2m180°
[PL1n
1"coupling'
DTG
DM
iennisgnem
Brlghtred
plugged
DM29MD_
2at90"
NPL12u
12"threaded nipple'
DM29
tat 90' ".
DM39MR_
Sal
NPLM
3/ethmdednipple'
DSB
Seel blue
DM39
Sat She "i
DM49MD_
4at90"
NPL1u
1"threaded nipple'
AKhM mmi
fiDDM
colors (powder
DM49
alarl "'.
mHrx
Extra handholec'
(SX/D5X/AERIS"/OMERO'Drill
MAEX
MakhexisUing'
DNYnU09z
USPOM
UnNedSMmpoiMof
DM19AS
1at 90'
manufacture
DM2MS
tat IW
It
Interlormating'
DM29AS
tat 90•
DM39AS
Book'
DM49AS
all
No . 5.
HwM ll an Is 181-ITCURanonstandad
1. Pfapenroppalesindudemp aRWM1enmedngtemn mmming 6.
Camblmdanohapon-mpandddll maudimudeexea
ardddll mauging lorthesamepole,MlwMhevmple:IXA1B/
Aandbele.
OR Themmbination incudesareguircd am M1andMk. 7,
MmaModglnalomernumbw
2. Theddllingtemplamto be card kra pardmlarlumLWredecenm q
i/stwhenmillamfimnwearenquiM.
J/\/\f
mtleluminaihethat lsused.Refertothe Bahnial0Ma5 nd 9.
the Copperginderfor Drilling Templates.
PmddeenhanadcorrwbnrtdnaM.
3. Inare'lbr l'mdesignatefiaturesia;e.g. DM199U 10.
AddmonalrolmsavailaAle;uewwx.lAhanla.mMaMmbn
4. SpedNhffimandmientationwle aderingoption.
arAKhheduml Colors brothure (Form No. 7943).PnAtlx
fimshwanal
Y: SceciMthe beigMinhdabpvekedcek.
0))
=5m420n=ID
br nd . S c ode nu aonfiomhan0mk wa OI
ceN
2
SSS-1
HANDHOLE ORIENTATION
IMPORTANT INSTALLATIONMOH4
C
• Up nor Bred Wild whim having m
Installed.
Famery-supplied amplaas tom Am mN
when who, anchor bales 111IKnh Lighting
will creator calm Nor inom andmge
D B
placement due upfailuR,Rmr, Nona
Uniongfanorymmplams.
• Isralel a restored oumde, all proterane
-'- --
wmppmg must as remwedstrogest,
'- '-
upon deliverympmemfinimmmage.
A
•1shmalcAminampasOmaBhfathe
Handhole
foondamndeslgn.
FIXTURE "06" POLE
BLa aeries
DIMENSIONSAr
pa. m She i
. Itaot col
ORDERING INFORMATION
mA LID met m
& PLE HUMBER: RIAmNMa2]PK
C pWo unit kod Pli LID and Nab H993 serws LID hcushg, or compounds 4- En screw based hauling(sea:
Housing CompeBbllity,
RIA LED arrd housing M be Ordwal windo w,
W mN
RlAgawHWg -- en LED Retrofit Module wirer renal boob and lone wilco BMIM aM Rip mCW 27W
9 g.
RL1msN8T7ML-PLED Petrom Module with crease baffle and lens Smli Nickel
mC00K n g.
RIABOWNBmpK=a"LED Retrofit Module and ForA AS CRI, 30WK
regresses We and lens, Whim Beene and R'mg,
with sspe baXle and lend Srt Nickel Berme aM RD I. CRI, 3W]K
Ring,
RIAmsN630PK= 4" LED Reagan Module wiith
der it
RL46pWN89aPK=4' LED Retrofit Maeda with regresses Dame and lens, White Bella vet Ring, m CRI, 33mK
C
SOCRI
RIABOWHMPI 4' DIED cement Module with r yrgsetl We antl lens, White Berme aM Ring. Ba CRI, 27WK
RIAm0N927PK= 4" LED Sol Module with regressed We and lens, Satin Nickel Baffle ands Ring, Po CRI, 27MK
Rb H930PK=a- LED Retrofit Module with MmsW We and lens. White Baffle and Ring. W CRL 301
RUMN830PK= a" LED normal Module with proposed 6 me antl lens, Said Nickel Baffle and Ring, 0CRI, 3 gDOK
RL HWBPK= 4' LED Retrom Module with ro7rMsed We and lens, White Baffle aM Ring, m CRL 3501
xEiBERFmgamnem mewtom wepter have ndt with unit)
LID Iloural
HMNCAT= Be Dedicated LED lrwJ WC3M.AIR-T New Gmsbmion Normal with LED language, connector Nigh series, c reomplexes
x M,AT= V Designed! Ined! Lnominal CtllBg,NR-= Nicol Housing with m LED luinorm ban high affi ycompllnvq
HOUSING COMPATIBILITY - Eta SCREW BASE RETROFIT
UL LISted
All -Pro"
ET400ATSB, E1`400RATSB, E1400ATSB
UUCUL Listed for installation in the following Halo
and All -Pro 4" recessed E26 screw based and LED
castedhousings.
dedicated
Halos
H991CAT, H99RTAT, H99TAT, H9951CAT, H995RICAT
Utilitech
CRO41CAT
Thomas®
PS4
UL CMsamed
Uthore a Ughfings
L3, L3R
UL Classified for retrofit in the following 4" recessed
Commercial Electric"
HBR2000B
E26 screw based housings.
JunosTC1R
Progress Lighting®
P830-TG, p632-TG
Jum•, Llitgnle U9hthg•,TMvm•Ughtlng•Proposal homing, Drill and Commermlel Elweb• MMrpmdwt
bask ream, what Mer W erbovm, ever bedaemmarbedemer ofamh
mepectlw oompmry Brd Cooper memo no om�ons on than tmdemaMa.
Nqv. armfi"Mion• antl pi,n,um• f ubjwt b vMrye wales[ ruEu.
Vlach our web she an www.aoopMlghtlm.mm
C RLighting
Customer Fimt Center 1121 Highway74 South Peachtree Cory, GA 30269770.4eBA800 FAx 7704ea l
�'COOPMlghft.� Cooper Lighting 652E McLaughlin Rd. Mississauga, Onmrio, Canada 1.511 IN W5.W7A0m FM 905.a 7M
RADIUS WALL SCONCE
Fixture Specifications
FEATURES
• Durable cast aluminum housing
• Available in various lighting
distribudons for maximum versatility
• Integrated design eliminates high
angle brightness
• Luminaire finished in weatherproof
powder -coat paint
ORDERING INFORMATION
The RWSC Series radius wall sconce offers maximum
versatility with multiple light sources and finishes. The
available combination of uplight/downlight washes
the buildingfacade while the radial soft fans housing
8
will complement similar architectural design elements.
• Completely sealed flat tempered
glass lenses suitable for use in wet
location
• Ships complete wish lamp
DIMENSIONS
O
72T I60' 90"
RWSC JDEXKXK
XX XX XXK
$trite
VAMV
lignian Visual
R1114C
Radius Wall Storrs,
DID Up/DownllRhc
120
120wk
LYD DownlightonN(Wdedlstcbudon}smndard
2117T
2T7sot
•
FT Downligh[onN lrorwand [hravl
A1T
hWLLlhp
TOPMH
70mttpuMmftr Whalide
f00PMX
100wa0NMs mnmemlh
•
150PMH
1501nenpul2iDrtrMWhaak
m Dark Bronze
OSL
OwlpresMlxwiNlampe
TMPS
70 watt high prey smfium
m Black
P
Singlerusing
l0
100watoh%hp u.s um
1kI11 Whim
R
Double Nosing
1SOHPS
150 WALL no normal sawdum
PS Padmum SlNer
EM11'
1hWll/MR15tvDpinsaie[Porl2vpoWer
2$W
26mttgm Wm fluore9ceAt
(byMers)35wmau35w Mill loop
83TAP
32 wan [dpk robe Oxorescen[
1 ,MudbA'YbcaU-anq wv>gemNma�
2aam,fiMw,raMM.OwMIamP
xrLdmL
410E
42vamtgmdmbefluore t
aaaubNw lxowloaa
2E1N1Y 2hY0/NRtbmapmspdem PorlN
M=
30WAn LED''
s i�rrmlwi tom
pw•er(tyW )35wmmc35 Wll
p I EM fiTThom baU3s[ Aawesan[on
SAxu•eazsammwa rwc mwwxr
Performance Designed Ughting Products ra w,aecaraPagh&g.tmm
1085 Johnson Drive • Buffalo Grove, IL 60089 • ToLL-FREE: 800-544-4848 • PHONE: 847-279-0627 • TAW: 847-279-0642
MFR SPECS FOR FIXTURE '90A" & "W"'
OA: RWSC-50PMH-FT-BK-120 (CUSTOM WATTAGE FOR CFA)
OJ: RWSC-50PMH-WD-BK-120 (CUSTOM WATTAGE FOR CFA)
Troy
DECORATIVE SURFACE SERIES
Pendant and Surface Family -DAMP LOCA77ON
Cylinder Full Cut -Off- Dade Sky
We reserve the rightre Rome tle design errwmponemserrany PaduawW Mice.
a USLAE GTALOC tl
TYPE
ARRA4 PROIERhOGTION
Compliant
APPROVED BY
SPECIFICATIONS
•BALIAST- For Canpact National Rachel Cold Mveamer High is Aa M.
•HOUSING - Open heavy gauge aluminum rylinder in Powder Count Hnish applied offer prdre surfaces.
• LAMP- Double (DTO or Triple Twin Tube (Ten Compact Fluorescent- Ballast Mmt be Normal when
chrosing any CFL lumping; PAR 20 Meml Halide Down Light- BY OTHERS.
•LENS-.1 See CI.Tempa Clanass, is Somali Gandhi 56.(73 Prismapic Tempered Gless(93).
• MOUNTING -surface or Pendant (®pacify Nil Mount. Optional Set Pendant for INDODR/DAMP
Located Only (canopy included).
•REFLECTOR-.032 Sisal Aluminum Sm M
• SOCKET -Pasteurized! porcelain
• U W LC LISMd M U.S. and WnOldn ufety mndads - SuiW le for wen (Maims.
L 16/z
M
-_•/ L
- T•-
F- T•�
TYPEIDTY AGE
Visit wwksli in i dorral ED ITS Pines
Fixture
oY
Dimensions -Wz H x D
"D .xB"
7' '.x16'/a"
"Dla,x20"
Fluorescent Double Twln Tuba
Orr ®
1)3
)3Val
Fluorescent Triple Twin Tube
FITT®
(1)26rM42w
(11 214
2 214
PAR Meml Halide Down
PAR-MHD
2111
2
Light Emitting Diode Doligtd
LEDD
15.
25w
Ught Emitting Diode Upright
LEDU
15w
25w
(LED salves me tubed m mmnel M. W.,
Troy WMl Mount. DOWN light
ARM:nBKn Affm tM1 A,\ 13'ARM
Troy Wall MouM-UPBDOWNIight
s.d. S le lam /Watt
/
Col., Ted '"a,1 I e: Prilll
/Erie
ORDERING GUIDE:
$Falb
1pUGE
OR s
NOTE$:
1Y = T'nYSeeea
In . leavdn
=
O Calwal Facto b as
ry cs
Sri
E - e•Ta-mall cal
2n - 2nvom
par -347Wh( auhk.,)
a3 -
regarding lamp sources,
murce,
tb = 1rs"ItH ID•a.)
EB . Electronic Ball=Y
_
including LEDwI« as
asp=2a'Tall O'fla.l
Flrvxx
m-
warnings, orraal nd ha
$KNO
Bx - Black
gE = Brmaa
m
e Consult Factory (or additional
car anal
Pepsi
FEND MdaMMw,4-$bndaN 74'Seem
pryer = qh 1Na lNumhnwn
EMme offe -
'&enp 'Y epl,One
noreumm srnn speclNlvhed0
was -whin
Ok =
FUs =
h°wn.
5pcily:5m=5hhc Carom%
4wY-Swivel Caaq
FMmCENEYMT OPTIONS®
GLE _
gl Ban., m a,, beremore when
D•' _ Q911rAMnud
NnmJhea m"vm mkxn,LM
m _
cbwaing airy CFL tamping
wet = Wall NeudnQnra ARM,
S3e0M' my MVry mmwe,
so =
g3 Nd Available with Swivel
WAPTwBF/IAMFOl1ANnTYM1VATTNGF
M120Vm Y1TN
m.x m,Mq. Tn: 1 i Lamp; 650 L"mens
$WT_
Fendam
Eerp'bAbmt CL,l
REmx=kcMg Gld Weadre, LOMine1
WFN
LED MMRTEM,
DTTmT: Las Lamp: "p 11 1250 Lrm.
Bar - mongrel
a - wr N"m
$k 5MOKraage
Bar Yolismge
:ECLIPSE'" 920 W. 1.5L l 5d Uwe Park, It W76
,LIGHTING P:m7-26 3331 F: 7-26a03M IE: WaksB ipwllgMingNecwn l W: clipeadigheinginemen
4 MFR SPECS FOR FIXTURE "OH' CS
RL460WH830PK (PROVIDED WITH CANOPY PACKAGE)
Finish O ti
M""m
ozol3 rahPe udmrahhc
Dcvnave sreW.e Rev.Ral pg.161-v
lan R7, 2ot4
MFR SPECS FOR FIXTURE "OL"
TY20-WM-LEDD-3K-120-BK-ARM6-WET
J
Z
O
LU
U
Z
LU
LU
LL
LU
QL
LL LL
0
O LLU
f
m
Cn
r1((goo
o,
� O ooD D(, p
5200 Buffington Rd.
Atlanta Georgia,
30349-2998
Mark Date By
0
Mark Date By
Mark Date By
Mark Date By
Mark Date By
Mark Date By
Mark Date By
Kurzynske & Associates
ONSULTING ENGINEERS
825 Third Avenue, South
Nashville, Tennessee 37210
Telephone: (615) 255-5203
Fax: (615) 255-5207
Email: mail@kurzynske.com
STORE
Pantops FSU
S08A
Pantops Drive
Charlottesville, VA
SHEET TITLE
Photometric
Details
VERSION: V9.1
ISSUE DATE: 8-2013
Job No. : CF1352
Store 31# 87
Date :2/24/14
Drawn By : BTS
Checked By: MTK
Sheet
ES2.2