Please accept the following in response to comments from April 6, 2022:
220 E. Central Pkwy, Ste 4000
Altamonte Springs, FL32701
407-645-5008
nterplanllccom
Comment: The symbology depicted in the Luminaire Schedule does not seem to match the
lighting symbols used on the plan map. Please review and revise for better alignment
Response: See Luminaire Schedule for symbol match.
Comment: There appears to be one additional light along Luxor Road, close to the intersection
of State Route 250, east of the building, that is not accounted for in the Luminaire Schedule. Please
advise accordingly.
Response: See revised Luminaire Schedule on Sheet ES-1.0.
Comment: Please see additional comments provided by the ARB Reviewer Margaret Maliszewski
below.
Response: See comments added below.
Previous comments by Margaret Maliszewski mmaliszewski(aalbemarle.ora answered on 2-8-22, with
some additions.
4. Comment: (Item #3) Revise lighting plan using an LLF of 1.0.
Response: Please see revised Luminaire Schedule on sheet ES1.0
Comment: Provide on the plan the cut sheets for pole fixtures.
Response: The pole fixtures are existing to remain. We are only adding Canopy fixture Lon
ES1.0.
Interplan LLC I AR00115951 CA 8660 Serving Restaurant and Retail Brands Nationwide since 1972.
ro INTERPLAN
Chick-Fil-A 3187, Charlottesville VA
April 29, 2022
Page 2 of 2
6. Comment: Revise the lighting plan to make clear which options have been chosen for all new
fixtures
Response: Please see revised cut sheet on sheet ES1.0 for new fixture L.
Comment: Revise the lighting plan to indicate a warm white color temperature (3000K) for the
lamps for the new fixtures.
Response: Please see revised cut sheet on sheet ES1.0
8. Comment: Revise the lighting plan to indicate the finish forthe pole fixtures. Black is
recommended.
Response: The pole fixtures are existing to remain. We are only adding Canopy fixture Lon
ES1.0.
9. Comment: (Item #8) Add the standard lighting note to the plan: "Each outdoor luminaire
equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall
be arranged or shielded to reflect light away from adjoining residential districts and away from
adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential
or rural areas zoning districts shall not exceed one half footcandle."
Response: The lower lumen type L canopy fixture is a 3000 full cutoff fixture. All 00-1 and
OG-2 pole fixtures are existing to remain and are not affected under this scope of work.