Loading...
HomeMy WebLinkAboutSE202200026 Correspondence 2022-05-04 (2)SITE INFORMATION PROJECT DESCRIPTION: PROJECT CONSISTS OF REMOVING (3) ANTENNAS & (7) COAXIAL CABLES. FOLLOWED BY INSTALLING (3) ANTENNAS, (3) INTEGRATED ANTENNAS & RRH UNITS, (6) RRHS, (1) OVP & (1) HYBRID CABLE. THE FINAL TOWER CONFIGURATION WILL BE (6) ANTENNAS, (3) INTEGRATED ANTENNAS & RRH UNITS, (6) RRHS, (1) OVP, (6) COAXIAL CABLES & (1) HYBRID CABLE. SITE ADDRESS: 1633 MONACAN TRAIL GOODS BRIDGE, VA 22903 LATITUDE (NAD 83): 37.995417 LONGITUDE (NAD 83):-78.581556 GROUND ELEVATION: 663.50'± (AMSL) JURISDICTION: ALBEMARLE COUNTY ZONING: RA, EC PARCEL ID: 08900-00-00-00400 PARCEL AREA: 6.36± ACRES PARCEL OWNER: CANODY, JOHN C OR ANITA L 1633 MONACAN TRAIL RD CHARLOTTESVILLE VA. 22903 TOWER OWNER: VERIZON WIRELESS 1831 RADY COURT RICHMOND. VA 23222 STRUCTURE TYPE: MONOPOLE CLASSIFICATION GROUP: U CONSTRUCTION TYPE: 2B STRUCTURE HEIGHT: 89' (AGL) RAD CENTER: 92' (AGL) TOP OVERALL HEIGHT: 97.9" (AGL) TOTAL LEASE AREA: 1200 SQ. FT. POWER PROVIDER: DOMINION TELCO PROVIDER: CENTURY LINK EMERGENCY INFORMATION: FIRE & RESCUE DEPARTMENT: POLICE DEPARTMENT: APPLICANT: (434) 296-5833 (434) 296-5807 PROJECT TEAM CONSTRUCTION MANAGEMENT FIRM ENGINEERING FIRM: VERIZON WIRELESS 1831 RADY COURT RICHMOND, VA 23222 NETWORK BUILDING + CONSULTING, LLC. 120 EASTSHORE DRIVE, SUITE 300 GLEN ALLEN, VA 23059 (804)548-4079 NB+C ENGINEERING SERVICES, LLC. 120 EASTSHORE DRIVE, SUITE 300 GLEN ALLEN, VA 23059 (804)548-4079 tsnarr@nbcllc.com ■ SITE NAME: MOORES CREEK 4G PCS -CARRIER ADD 1633 MONACAN TRAIL GOODS BRIDGE, VA 22903 ALBEMARLE COUNTY VICINITY MAP SCALE: 1" = 1000' Sherwo Pit— Hills Store onor r Nd hi SITE 1633 Monacan Trail Rd, Charlottesville, VA 22903 006 z z w , ,/011111" " Aiiowhead t� DIRECTIONS HEAD SOUTHWEST ON RADY ST TOWARD MAGNOLIA ST. TURN RIGHT ONTO MAGNOLIA ST. MAKE A U-TURN TO STAY ON MAGNOLIA ST. TURN RIGHT ONTO US-360 W / MECHANICSVILLE TPKE. TAKE THE RAMP ON THE RIGHT AND FOLLOW SIGNS FOR 1-95 / 1-64 WEST. TAKE THE RAMP ON THE RIGHT FOR 1-95 N / 1-64 W. AT EXIT 79, HEAD RIGHT ON THE RAMP FOR US-33 TOWARD STAPLES MILL RD. AT EXIT 118A, HEAD RIGHT ON THE RAMP FOR US-29 SOUTH TOWARD LYNCHBURG. MAKE A U-TURN TO STAY ON US-29 N / MONACAN TRAIL RD. ARRIVE AT US-29 N / MONACAN TRAIL RD WITH SITE LOCATED ON THE RIGHT. CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING CODES. • 2018 BUILDING CODE • ANSI/TIA-222-H • 2017 NATIONAL ELECTRICAL CODE • TIA 607 • 2018 NFPA 101, LIFE SAFETY CODE • INSTITUTE FOR ELECTRICAL & ELECTRONICS ENGINEER 81 • 2018 INTERNATIONAL FIRE CODE (IFC) • IEEE C2 NATIONAL ELECTRIC SAFETY CODE LATEST EDITION • AMERICAN CONCRETE INSTITUTE • TELCORDIA GR-1275 • AMERICAN INSTITUTE OF STEEL CONSTRUCTION • ANSI/T 311 • MANUAL OF STEEL CONSTRUCTION 15TH EDITION • 2018 VIRGINIA CONSTRUCTION CODE CONTRACTOR PMI REQUIREMENTS PMI ACCESSED AT: VZWMOUNTS@NBCLLC.COM SMART TOOL VENDOR PROJECT PROJECT NUMBER: N/A VERIZON LOCATION CODE (PSLC): 495413 PMI AND REQUIREMENTS ALSO EMBEDDED IN MOUNT ANALYSIS REPORT HARDWARE UPGRADES REQUIRED YES VERIZON APPROVED VENDORS " REFER TO CONSTRUCTION DRAWINGS. DRAWING INDEX T-1 TITLE SHEET C-1 COMPOUND PLAN C-2 ELEVATION A-1 EQUIPMENT SCHEDULE A-2 EQUIPMENT DETAILS G-1 GROUNDING RISER DIAGRAM & DETAILS APPENDIX MOUNT MODIFICATION DRAWINGS DO NOT SCALE DRAWINGS THESE DRAWINGS ARE FORMATTED TO BE FULL-SIZE AT 24"X36". CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE DESIGNER / ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR MATERIAL ORDERS OR BE RESPONSIBLE FOR THE SAME. CONTRACTOR SHALL USE BEST MANAGEMENT PRACTICE TO PREVENT STORM WATER POLLUTION DURING CONSTRUCTION. APPLICANT: APPLICANT VERIZON WIRELESS 1831 RADY COURT RICHMOND, VA 23222 MEG BROWN (804)543-9908 z 0 0 w z w 0 w w z U) w IZ Q J z 0 w ILL Ir IL w w z (5 z w w J w w rn Ir w cc z w w TOTALLY COMMITTER NB+C ENGINEERING SERVICES, LLC. 120 EASTSHORE DRIVE, SUITE 300 GLEN ALLEN, VA 23059 804-548-4079 verizonli 1831 RADY COURT RICHMOND, VA 23222 MOORES CREEK 4G PCS - CARRIER ADD NB+C ES PROJ. # 100352 1633 MONACAN TRAIL GOODS BRIDGE, VA 22903 ALBEMARLE COUNTY REVISIONS 1 1 03/16/22 1 FINALS I KLB 0 02/28/22 PRELIMINARY KLB REV DATE DESCRIPTION BY LTH OF D Lic. No. 049978 p DATE 03/16/22�w� TRENT T. SNARR, P.E. VA PROFESSIONAL ENGINEER LIC. #49978 TITLE SHEET T=1 ll�r EXISTING 89' MC EXISTING VERIZON EXISTING VERIZON BATTERY CABINET ON CONCRETE PAD (TYP.) EXISTING VE, 9412 LTE E Lu TM LJ v EXISTING VERIZON COAXIAL CABLES TO REMAIN (z—'3 707Q i D° z LJ NB+C ENGINEERING SERVICES, LLC. 120 EASTSHORE DRIVE, SUITE 300 GLEN ALLEN, VA 23059 804-548,4079 FIBER BOX EXISTING VERIZON EQUIPMENT CABINET ON CONCRETE PAD J verizonit a_ Q 1831 RADY COURT RICHMOND, VA 23222 0 MOORES CREEK 4G PCS - CARRIER ADD o NB+C ES PROJ. # 100352 z 1633 MONACAN TRAIL U-1 GOODS BRIDGE, VA 22903 ul I I ALBEMARLE COUNTY 0 Ir 0 U Lu rr z 0 U) W r) 7 REVISIONS 1 103/16/22 1 FINALS I KLB 0 02/28/22 PRELIMINARY KLB REV DATE DESCRIPTION BY • 4 a. .4. I� Q z � A IS v 0 Lic. No. 049978 EXISTING GENERATOR W ��� ON CONCRETE PAD DATE 03/16/22 LL �C5 (TYP.) 0 SSpCIVAL T EXISTING UTILITY EQUIPMENT ON EXISTING H—FRAME (TYP.) FziLL TRENT T. SNARR, P.E. COMPOUND PLAN C 1 SCALE: 3/8" = 1' - - - - (TYP.) GRAPHIC SCALE 2 0 1 2 4 8 (IN FEET) 3/8 INCH = 1 FOOT 0 11 VA PROFESSIONAL ENGINEER LIC. #49978 n LJ J COMPOUND PLAN LJ Ir LLI CD z -1 LLI GENERAL NOTES NOTE: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES Imm TPo POST —MODIFICATION INSPECTION PMI REQUIRED ON ALL PROPOSED VERIZON ANTENNA ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITIES COMPANY OR OTHER PUBLIC AUTHORITIES. cr 3j4 SITES. REFER TO THE MOUNT ANALYSIS PREPARED BY COMMSCOPE NN4HSS-65C—R3BT8 w (TYP. OF 1 PER SECTOR, TOTAL OF 3) uJ NB+C ENGINEERING SERVICES, LLC. DATED 02/28/2022 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS z 707QL LY CO TTE Do FOR ADDITIONAL DETAILS. AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, PROPOSED VERIZON MOUNT MODIFICATION COUNTY OR MUNICIPAL AUTHORITIES. z w NOTE: (SEE ST SHEETS FOR DETAIL) NB+C ENGINEERING SERVICES, LLC. MOUNT MODIFICATIONS ARE REQUIRED BEFORE ANY INSTALL 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION 20 EASTALEN, VA 2SUITE 300 GLEN3059 CAN OCCUR, PLEASE REFER TO THE MOUNT MODIFICATION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN 04-548-4079 DRAWINGS PROVIDED BY NB+C ENGINEERING SERVICES, LLC. THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM DATED 02/28/2022 PROPOSED VERIZON ANTENNA RAD CENTER jL RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. ELEV.=92.0' AGL 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING PROPOSED VERIZON INTEGRATED RRH & ANTENNA MT6407-77A TOP OF EXISTING TOWER SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE (TYP. OF 1 PER SECTOR, TOTAL OF 3) ELEV.= 89.0'AGL CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL EXISTING VERIZON ANTENNA RAD CENTER MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS I ELEV.=85.0AGL PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE Verizon � MANUFACTURERS RECOMMENDATIONS. Q EXISTING VERIZON ANTENNA BXA-80090-6CF TO REMAIN J . OF 1 PER SECTOR, TOTAL OF 3 � 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A (TYP % BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE PROPOSED VERIZON RRH RAD CENTER OIL BID THE CONTRACT DOCUMENTS. Q 1831 RADY COURT ELEV.=80.0' AGL RICHMOND, VA 23222 I 7. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF PROPOSED VERIZON OVP RAD CENTER OIL ENGINEERING PRIOR TO INSTALLATION. ELEV.=77.0' AGL PROPOSED VERIZON SAMSUNG B2/866A RRH 8. TRANSMITTER EQUIPMENT AND ANTENNAS ARE DESIGNED TO MEET ANSI/TIA /wo nr I oro crnTno TnTAI nr Z% 222—G REQUIREMENTS. PROPOSED ELEVATION SCALE: 3/16" = 1' GRAPHIC SCALE 4 6 2 4 8 16 (IN FEET) 3/16 INCH = 1 FOOT 9. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 10. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES z MOORES CREEK PRIOR TO EXCAVATING. O 4G PCS -CARRIER ADD 11. IF ANY UNDERGROUND UTILITIES OR STRUCTURES EXIST BENEATH THE PROJECT AREA, CONTRACTOR MUST LOCATE IT AND CONTACT THE cc NB+C ES PROD. # 100352 APPLICANT & THE OWNER'S REPRESENTATIVE. O ILL 1633 MONACAN TRAIL 12. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION BY — TECHNICIANS APPROXIMATELY 2 TIMES PER MONTH. LLJ GOODS BRIDGE, VA 22903 13. PRIOR TO THE INSTALLATION OF THE PROPOSED EQUIPMENT OR F15 ALBEMARLE COUNTY MODIFICATION OF THE EXISTING STRUCTURE, A STRUCTURAL ANALYSIS SHALL BE PERFORMED BY THE OWNER'S AGENT TO CERTIFY THAT THE EXISTING/PROPOSED COMMUNICATION STRUCTURE AND COMPONENTS ARE STRUCTURALLY ADEQUATE TO SUPPORT ALL EXISTING AND PROPOSED ANTENNAS, COAXIAL CABLES AND OTHER APPURTENANCES. REVISIONS 14. PROPERTY LINE INFORMATION WAS PREPARED USING DEEDS, TAX MAPS, AND PLANS OF RECORD AND SHOULD NOT BE CONSTRUED AS AN ACCURATE BOUNDARY SURVEY. 15. THIS PLAN IS SUBJECT TO ALL EASEMENTS AND RESTRICTIONS OF rr rr RECORD. O U 16. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN w STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE z PROPOSED. z CD U) 17. NO SIGNIFICANT NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS LLJ Q FACILITY. 18. THE FACILITY IS UNMANNED AND NOT INTENDED FOR HUMAN HABITATION 1 1 03/16/22 1 FINALS KLB (NO HANDICAP ACCESS REQUIRED). 0 02/28/22 PRELIMINARY KLB 19. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR REV DATE DESCRIPTION BY SANITARY SERVICE. 20. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. IZ �LTH OF G � o ��, J � j Q z A IS y 0 Lic. No. 049978 c��p DATE 03/16/22ILL w� 0 -`SILIVAL� w L II w w TRENT T. SNARR, P.E. z CD I I VA PROFESSIONAL ENGINEER LIC. #49978 i 119 w J w ELEVATION w cn m w m z W C=2 w cn ANTENNA INFORMATION CHART SECTOR STATUS ANTENNA MANUFACTURER ANTENNA MODEL RAID CENTER AZIMUTH MECHANICAL DOWN TILT ELECTRICAL DOWN TILT RRH QUANTITY &MODEL A 1 EXISTING ANTEL BXA-80090-6CF 85' 100' 0° SEE RFDS - Al B PROPOSEDI COMMSCOPE NNH4SS-65C-R36T8 92' 100' 0' SEE RFDS SAMSUNG 11)) SAMSUNG B2// 616A RRH ORAN 3 RRH ORAN ((RF4439D-2 A)) A2 PROPOSED SAMSUNG MT6407-77A 92' 100' 0' SEE RFDS (1) SAMSUNG MT6407-77A B1 EXISTING ANTEL BXA-80090-6CF 85' 220° 0° SEE RFDSSAMSUNG - BIB PROPOSED COMMSCOPE NNH4SS-65C-R36T8 92' 220' 0' SEE RFDS RRH ORAN j1)) SAMSUNG 62// 616A RRH ORAN ((RF4 39D 25A)) B2 PROPOSED SAMSUNG MT6407-77A 92' 220' O' SEE RFDS (1) SAMSUNG MT6407-77A C1 EXISTING ANTEL BXA-80090-6CF 85' 340' 0° SEE RFDS - C1 B PROPOSED COMMSCOPE NNH4SS-65C-R36T8 92' 340' 0' SEE RFDS j1)) SAMSUNG / SAMSUNG B2/613 RRH ORAN ( 6A RRH ORAN (RF4439D-2 A)) C2 PROPOSED SAMSUNG MT6407-77A 92' 340' 0' SEE RFDS (1) SAMSUNG MT6407-77A NOTES: 1. CONTRACTOR TO VERIFY PROPOSED ANTENNA INFORMATION IS THE MOST CURRENT DATA AT TIME OF CONSTRUCTION. 2. CONTRACTOR TO CONFIRM CABLE LENGTHS PRIOR TO CONSTRUCTION. 3. CONTRACTOR TO VERIFY ALL PROPOSED AND EXISTING ANTENNA AND CABLES WERE CONSIDERED AND PASSED A STRUCTURAL ANALYSIS PERFORMED BY A LICENSED ENGINEER PRIOR TO INSTALLATION. EXISTING VERIZON ANTENNA MOUNT TO BE MODIFIES (TYP. OF :XISTING 89 GNOPOLE EXISTING VERIZON ANTENNA TO REMAIN (TYP. OF 1 PER SECTOR, TOTAL OF 3) B� ANTEL 0 BE OJO-6CF EXISTING ANTENNA ORIENTATION PLAN NTS � � D T c� N o = m Z m 0 m EXISTING VERIZON ANTENNA M - - TO BE MOL (TYP. c EXISTING VERIZON ANTENNA TO BE REMOVED (TYP. OF 1 PER SECTOR, TOTAL OF 5) XISTING 89' ONOPOLE ALPyq AZ. 100 ° APPROX TRUE NORTH 85' BXggM0063O8CF BE REtijOVEO ALPyq AZ= 700° EXISTING ANTENNA ORIENTATION PLAN NTS APPROX TRUE NORTH 92' EXISTING VERIZON ANTENNA TO REMAIN (TYP. OF 1 PER SECTOR, TOTAL OF 3) PROPOSED VERIZON MODIFIED ANTENNA MOUNT (SEE ST SHEETS FOR DETAILS) XISTING 89 ONOPOLE ANTEL BXA-8pO'g 6CF ALP 4 gz=100° PROPOSED ANTENNA ORIENTATION PLAN @ 85' NTS APPROX TRUE NORTH 40DIFIED DETAILS) ,OPE �-R3BT8 A 2H & ANTENNA TOTAL OF 3) OF 3) APPROX TRUE NORTH NOTE: POST —MODIFICATION INSPECTION (PMQ REQUIRED ON ALL SITES. REFER TO THE MOUNT ANALYSIS PREPARED BY NB+C ENGINEERING SERVICES, LLC. DATED 02/28/2022 FOR ADDITIONAL DETAILS. NOTE: MOUNT MODIFICATIONS ARE REQUIRED BEFORE ANY INSTALL CAN OCCUR, PLEASE REFER TO THE MOUNT MODIFICATION DRAWINGS PROVIDED BY NB+C ENGINEERING SERVICES, LLC. DATED 02/28/2022 PROPOSED VERIZON B2/B66A RRH (TYP. OF 1 PER SECTOR, TOTAL OF 3) PROPOSED VERIZON 65/B13 RI (TYP. OF 1 PER SECTOR, TOTAL OF 3) PROPOSED VERIZON MODIFIED eniT�ninie MOUNT SHEETS FOR DETAILS) EXISTING 89' MONOPOLE PROPOSED RRH ORIENTATION PLAN @ 80' NTS EXISTING 89' MONOPOLE PROPOSED VERIZON OVP (TYP. OF 1) PROPOSED VERIZON MODIFIED ANTENNA MOUNT (SEE ST SHEETS FOR DETAILS) PROPOSED OVP ORIENTATION PLAN @ 77' IIIP APPROX TRUE NORTH APPROX TRUE NORTH cr- Lu w z z w z 0 0 LL z w U] 0 !r O U LLJ O" z CIS Lu 0 a_ Q U7 J Q z _O U7 cn Lu LL z a_ W LLJ z z Lu LLJ J LLJ LLJ c/) Ir Lu m z L w LLJ NTIM 7 7ALLY COMIMI TMDD. NB+C ENGINEERING SERVICES, LLC. 120 EASTSHORE DRIVE, SUITE 300 GLEN ALLEN, VA 23059 804-548-4079 verizonit 1831 RADY COURT RICHMOND, VA 23222 MOORES CREEK 4G PCS - CARRIER ADD NB+C ES PROJ. # 100352 1633 MONACAN TRAIL GOODS BRIDGE, VA 22903 ALBEMARLE COUNTY REVISIONS 1 103/16/22 1 FINALS I KLB 0 102/28/22 1 PRELIMINARY I KLB REV DATE I DESCRIPTION I BY Lic. No. 049978 I0 DATE 03/16/22 TRENT T. SNARR, P.E. VA PROFESSIONAL ENGINEER LIC. #49978 EQUIPMENT SCHEDULE Ami IIIIIIIIIIIIIIIIIIIIII� ;li • • II Illililililililililililil III II , ., • I IIII�III�IIIIIIIIIIIIII��� II ,: IIIII�III�III�IIIII�III��I IIIIIIIIIIjljlllll ,. IIIIIIIIIIIIIIIIIIIIIIIIIIII I III III I III I III III IIII III' iiiiiiiiii�iiiiiii iil Innnn'»«"I' iiii""I"iiiiiii lii IIIIIIIIIIIIIIIIIIIIIIIIIIII FRONT VIEW SIDE VIEW BOTTOM VIEW SAMSUNG B2/B66A RRH RF4439d-25A NIS O T iA M 18" �21"� COMMSCOPE RCMDC-6627—PF-48 NTS 7. 76" PROPOSED PANEL ANTENNA (SEE ANTENNA SCHEDULE) PROPOSED ANTENNA DOWNTILT BRACKET PROPOSED ANTENNA MOUNTING PIPE TO BE ADJUSTED AS NEEDED R TO OBTAIN ANTENNA SEPARATION (TYP OF EACH SECTOR) 01 PROPOSED ANTENNA MOUNTING BRACKET ANTENNA WEIGHT 102.294 LBS 19.6" CID I` r 14.96" �) I oppDOD�D�DOD�DOD00�DODpOpo o0Do0oDoDoOoDoDoDoDoDoDoO °UOo0o0o00000000000000000 00000uouoo00000u00000uoopo oppopopopopopopopopopopopo WEIGHT = 72.5 LBS 14.96" FRONT VIEW SIDE VIEW BOTTOM VIEW SAMSUNG B5/B13 RRH RF4440d-13A NTS COMMSCOPE NNH4SS-65C-R3BT8 N I S FRONT VIEW 5.51" ®000 000 000 ®000 000 0 0 0 0 0 0 •000 SIDE VIEW o ui M0 WEIGHT = 81.6 LBS 16.06" TOP VIEW SAMSUNG MT6407-77A RRH & ANTENNA NTS LO ui cr w w z z w Z 0 cr 0 LL z w 0 0 0 Lu w z (3 U) w Q Z 0 U7 W LL Lu w z Z w w J w rr w m z w TOTALLY COGiIIM44EDDe NB+C ENGINEERING SERVICES, LLC. 120 EASTSHORE DRIVE, SUITE 300 GLEN ALLEN, VA 23059 804-548,4079 verizon� 1831 RADY COURT RICHMOND, VA 23222 MOORES CREEK 4G PCS - CARRIER ADD NB+C ES PROJ. # 100352 1633 MONACAN TRAIL GOODS BRIDGE, VA 22903 ALBEMARLE COUNTY REVISIONS 1 103/16/22 1 FINALS I KLB 0 1 02/28/22 1 PRELIMINARY KLB REV I DATE DESCRIPTION BY TH OF - Lic. No. 049978 1, DATE 03/16/22 ,' `rICIVAL �� TRENT T. SNARR, P.E. VA PROFESSIONAL ENGINEER LIC. #49978 EQUIPMENT DETAILS A=2 GROUNDING NOTES ALPHA SECTOR BETA SECTOR GAMMA SECTOR r* ■ TM 1. GROUNDING SHALL COMPLY WITH NEC ART. 250. ADDITIONALLY, GROUNDING, PROPOSED ANTENNA Lu ^ VEORIDZING ON WIRELESS DTING GROUNDINGCTION SHALL STTANDARDS. BE DONE IN ACCORDANCE WITH (NP. OF 3) TW L LY bO M M J T7 E Do 2. GROUND CABLE SHIELDS MINIMUM AT BOTH ENDS USING MANUFACTURERS Lu CABLE GROUNDING KITS SUPPLIED BY PROJECT OWNER. PROPOSED INTEGRATED RRH NB+C ENGINEERING SERVICES, LLC. & ANTENNA (TYP. OF 3) 120 EASTSHORE DRIVE, SUITE 300 ALLEN, VA 3. USE #6 COPPER STRANDED WIRE WITH GREEN COLOR INSULATION FOR GLE 804-W-40793059 ABOVE GRADE GROUNDING (UNLESS OTHERWISE SPECIFIED) AND #2 SOLID TINNED BARE COPPER WIRE FOR BELOW GRADE GROUNDING AS INDICATED ON THE DRAWING. 4. ALL POWER AND GROUND CONNECTIONS TO BE CRIMP —STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY HARGER (OR APPROVED EQUAL) RATED FOR OPERATION AT NO LESS THAN 75'C OR CADWELD EXOTHERMIC WELD. DO NOT ALLOW BARE COPPER WIRE TO BE IN CONTACT WITH GALVANIZED STEEL. 5. ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE, EXCEPT AS OTHERWISE INDICATED. GROUNDING LEADS SHOULD NEVER BE BENT AT RIGHT ANGLE. ALWAYS MAKE AT LEAST 12" RADIUS BENDS. #6 WIRE CAN BE BENT AT 6" RADIUS WHEN NECESSARY. BOND ANY METAL OBJECTS WITHIN 6 FEET OF PROJECT OWNER EQUIPMENT OR CABINET TO MASTER GROUND BAR OR GROUNDING RING. 6. CONNECTIONS TO GROUND BARS SHALL BE MADE WITH TWO HOLE COMPRESSION TYPE COPPER LUGS. APPLY OXIDE INHIBITING COMPOUND TO ALL LOCATIONS. 7. APPLY OXIDE INHIBITING COMPOUND TO ALL MECHANICAL GROUND CONNECTIONS. 8. CONTRACTOR SHALL PROVIDE AND INSTALL OMNI DIRECTIONAL ELECTRONIC MARKER SYSTEM (EMS) BALLS OVER EACH GROUND ROD AND BONDING POINT BETWEEN EXISTING TOWER/ MONOPOLE GROUNDING RING AND EQUIPMENT GROUNDING RING. 9. CONTRACTOR SHALL TEST COMPLETED GROUND SYSTEM AND RECORD RESULTS FOR PROJECT CLOSE—OUT DOCUMENTATION. 5 OHMNS MINIMUM RESISTANCE REQUIRED. 10. CONTRACTOR SHALL CONDUCT ANTENNA, CABLE, AND LNA RETURN —LOSS AND DISTANCE —TO —FAULT MEASUREMENTS (SWEEP TESTS) AND RECORD RESULTS FOR PROJECT CLOSE OUT. MOUNTING BOLT (VARIES J WITH MOUNTING APPLICATION) ®®6"0 DIRECT BOLT MOUNTING 60000 0 0 0 0® ®0 0 BRACKETS WITH GROUND BAR) D ®®000 00 ®6600ve 00 ®0 0080000 ®000 ®®00 ® 0 0 0 ®® 0 0 GALVANIZED STEEL GROUND BAR ® 0 0 0 6600 0 O (HOLE CENTERS TO MATCH NEMA 0 0 ®0 0 0 DOUBLE LUG CONFIGURATION) 660Oo INSULATORS (TO BE USED WHEN THERE IS A HOME RUN ON TOWER) NOTE: THE GROUND BAR SHOULD BE MADE OF GALVANIZED STEEL (ALLTEC CORP PART #TB-74 VZW-20 OR EQUIVALENT) INSTEAD OF COPPER TO DETER THEFT. AN ALTERNATIVE TO THE GALVANIZED STEEL GROUND BAR IS A BARNONE/ERICO "THEFT DETERRENT GROUND BAR ASSEMBLY." 2 GROUND BAR DETAIL G 1 NTS ■ U verizonit J Q 1831 RADY COURT RICHMOND, VA 23222 rISRNG TOWER Oz MOORES CREEK ?OUND BAR Q 4G PCS - CARRIER ADD yP.) NB+C ES PROJ. # 100352 O z 1633 MONACAN TRAIL Lu GOODS BRIDGE, VA 22903 ALBEMARLE COUNTY 0 Ir O U Lu rr z c.� vD Lu 0 REVISIONS 1 103/16/22 1 FINALS I KLB 0 02/28/22 PRELIMINARY KLB REV DATE DESCRIPTION BY GROUNDING RISER DIAGRAM a_ G 1 NTS "VT" OF Q A IS y z 0 Lic. No. 049978 cc �� DATE 03/16/22 Lu ILL 0 s'S"WAL � Ir CL Ir Lu Lu z TRENT T. SNARR, P.E. z 0 VA PROFESSIONAL ENGINEER LIC. #49978 z Lu TYPE TA TYPE VN TYPE NC TYPE SS TYPE W TYPE VS Lu GROUNDING LuRISER DIAGRAM Lu TYPE VB TYPE PT TYPE GT TYPE GY TYPE GR TYPE GL co & DETAILS 3 CADWELD GROUNDING CONNECTION DETAILS G 1 NTS CE: LJ m z Gml w Lu cup