Loading...
HomeMy WebLinkAboutSUB201900058 Review Comments Road Plan and Comps. 2022-05-09NOTES GENERAL NOTES: 1. THIS BRIDGE HAS BEEN DESIGNED FOR GENERAL SITE CONDITIONS. THE PROJECT ENGINEER SHALL BE RESPONSIBLE FOR THE STRUCTURES SUITABILITY TO THE EXISTING SITE CONDITIONS AND FOR THE HYDRAULIC EVALUATION -- INCLUDING SCOUR AND CONFIRMATION OF SOIL CONDITIONS. 2. PRIOR TO CONSTRUCTION, CONTRACTOR MUST VERIFY ALL ELEVATIONS SHOWN THROUGH THE ENGINEER. 3. ONLY CONTECH ENGINEERED SOLUTIONS LLC, THE CON/SPAN® APPROVED PRECASTER IN VIRGINIA MAY PROVIDE THE STRUCTURE DESIGNED IN ACCORDANCE WITH THESE PLANS. 4. THE USE OF ANOTHER PRECAST STRUCTURE WITH THE DESIGN ASSUMPTIONS USED FOR THE COWSPANO STRUCTURE MAY LEAD TO SERIOUS DESIGN ERRORS. USE OF ANY OTHER PRECAST STRUCTURE WITH THIS DESIGN AND DRAWINGS VOIDS ANY CERTIFICATION OF THIS DESIGN AND WARRANTY. CONTECH ENGINEERED SOLUTIONS LLC ASSUMES NO LIABILITY FOR DESIGN OF ANY ALTERNATE OR SIMILAR TYPE STRUCTURES. DESIGN DATA DESIGN LOADING: BRIDGE UNITS: HL-93 HEADWALLS: EARTH PRESSURE ONLY WINGWALLS: EARTH PRESSURE ONLY DESIGN FILL HEIGHT: T-0" MIN. TO 5-6" MAX. FROM TOP OF CROWN TO TOP OF PAVEMENT. DESIGN METHOD: LOAD AND RESISTANCE FACTOR DESIGN PER AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, 8TH EDITION, 2017. HP12x53 FACTORED RESISTANCE = 190 KIPS (AXIAL) 24 KIPS (SHEAR) `FOUNDATION EXCAVATION AND SUBGRADE PREPARATION SHALL BE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT FOR THIS PROJECT PREPARED BY FROEHLING+ ROBERTSON, INC. DATED: 12120/2021, REVISED 314/2022. MATERIALS PRECAST UNITS SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH COWSPANO SPECIFICATIONS. CONCRETE FOR PILE CAPS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI. REINFORCING STEEL FOR PILE CAPS SHALL CONFORM TO ASTM A615 OR A996-GRADE 60. PILES SHALL BE PER ASTM A709 GRADE 50 WITH PILE POINTS. PILE SHALL BE DRIVEN IN ACCRDANCE WITH VDOT ROAD AND BRIDGE SPECIFICATIONS SECTION 403. DATE ( REVISION DESCRIPTION CNTECH' ENGIMEMID SOUMOM QC www.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45W9 800-338-1122 513615-7000 513 6457993 FAX PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA =N�SPAL 44-SERIES. CONTRACT DRAWING Y O O IY m 0 Z J m 9 LOCATION PLAN NOT TO SCALE QIECTNo. SEMNo, DATE: 689029 010 3/10/2022 PLEASANT GREEN SUBDIVISION —JMF ---JCH CHECKED: APPROVED: SPS PAC ALBEMARLE COUNTY, VIRGINIA SHEET NO.: CT1 DE Cl COVER ALL WINGWALL JOINTS WITH 2'-0" WIDE STRIP OF FILTER FABRIC DETAIL�� n ,0 a 10" DETACHED HEADWALL ~ D nFLOW— _ CT6 C� COVERALL CORNERS WITH 2'-0" WIDE STRIP OF FILTER FABRIC DETAIL, 12 - (0843) 4T-0" SPAN x 8'-9Ya" RISE x 5'-11%" LONG PRECAST CONCRETE BRIDGE UNITS PLUS 11 JOINTS @ Y"t PER JOINT 5,SPPO��o 6 AIL Qn V NNO�PL � r N �r 10"DETACHED HEADWALL - - - GSTRIx:TIIRF L. BRIDGE PLAN 00 4� 1,0. FAIL Q4T, KING 3 '-0. 10,0, 4t( @ 6,0 4"0 PERFORATED BACKFILL DRAIN SUPPLIED WITH WINGWALL (TYP.) mo,m.t11 ,"."9mwa.— ..,9,�..rea16 CNTECH' r .;w b,Ll9M 1:9.a9W o, fN�N�+�SP,Co,IV ... m...r9 e9�no �9o�.e��H �° ENGINEER SOlU OM QC SMIES lyh www.ContechES.com ,- °�'�-da ',;d°u,'- b"My° 9025 Centre Pointe Dr., suite 400, West Chester, OH a5069 CONTRACT ..'�....... b.9..N�. can ny„m,9n9".....9�m�:."9, �, w.xa MARK DATE REVISION DESCRIPTION gy 800338-1122 513615-7000 513645-7993 FAX of NG 0 3;0. PRIMER COMPATIBLE FILL LIFTING INSERT POCKET WITH JOINT WRAP WITH GROUT, FINISHING FLUSH TOP OF PRECAST 9" SQUARE PIECE BRIDGE UNIT OF JOINT WRAP III I( LIFTING INSERT PRECAST BRIDGE UNIT, HEADWALL OR WINGWALL TYPICAL LIFT INSERT SEALING DETAIL NOT TO SCALE oas o � o cv PRQIECT11- SEM No.: DATE: 689029 010 3/10/2022 PLEASANT GREEN SUBDIVISION Des DN JMF D� JCH CHECKED: APPROVED: SPS PAC ALBEMARLE COUNTY, VIRGINIA SHEET NO.: CT2 DE CT9 T/FOOTING ELEV. 689.84 6" q°Fs 09"0" T/FOOTING ELEV. 689.32 STRUCTURE LIMITS CT6 F�� T/FOOTING ELEV. 689.32 T/FOOTING nAd ELEV. 689.32 T/FOOTING ELEV. 689.72 5 3r-STl.r P / ydA 8'DEEP BLOCKOUT FOR 1� WINGWALL ANCHOR (TYP.) — HP 12 x 53 PILES (TYP.) 3:1 BATTERED HP 12 x 53 PILES (TYP.) STRUCTURE LIMITS 11 - SPACES Q 6r-0" (INSIDE) 2 - SPACES @ T-0" (OUTSIDE) L FOUNDATION PLAN 0 4' 8' 16 6" i Vy6"0 @ .d SPPGES g T/FOOTING ELEV. 687.94 — —LG RTRDCTIIRF J T/FOOTING ELEV. 687.94 \36�e" 9.0" T/FOOTING ELEV. 687.40 KEY: BATTERED 3:1 HP72 x 53 PILE 2 VERTICAL HP12 x 53 PILE PER F&R REPORT: ESTIMATED TIP ELEV. MIN. TIP ELEV. EAST 651-673 673 WEST 665-671 671 PER F&R REPORT: -WE RECOMMEND THAT THE PILE LOCATIONS BE PREDRILLED TO AN ELEVATION OF EL 680 TO PENETRATE THE ALLUVIAL SOILS. -THE PILES SHOULD BE DRIVEN TO A DRIVING RESISTANCE OF 292.3 KIPS AS DETERMINED BY THE PILE DRIVING ANALYZER TESTING (PDA). THE DESIGN FACTORED RESISTANCE IS BASED ON PILES DRIVEN TO 292.3 KIPS AND AN APPLIED RESISTANCE FACTOR OF 0.65 FOR PDA TESTED PILES. WE RECOMMEND A MINIMUM OF 1 TEST PILE BE PERFORMED ON EITHER SIDE OF POWELLS CREEK. -THE CONTRACTOR SHALL PROVIDE HAMMER AND CUSHION DATA FOR THE PROPOSED PILE DRIVING EQUIPMENT. THIS ANALYSIS SHOULD BE REQUIRED PRIOR TO MOBILIZING THE HAMMER AND EQUIPMENT TO THE JOB SITE. THE CONTRACTOR SHOULD ALSO ENGAGE WITH A GEOTECHNICAL ENGINEER TO PROVIDE PDA TESTING DURING DRIVING. NOTE: LAP (T-0-) #6 LONGITUDINAL BARS IN T/FOOTING WINGWALL AND BRIDGE FOOTINGS ELEV. 687.29 1 TO MAKE CONTINUOUS n rvpn�an°mormavon—mmv—r vr.— ^ PRQIECTNo.: SEMNo.: DATE: se ' a"'�°� .�rea� a w e.,�°,.n 7l�lrlw `\ 689029 010 3/10/2022 "aro: :°ran a. CNTECH' //7 ##Yy..L��iii..iii###»>lll i ��" m. Prmr.nn.a.°°..mm C PLEASANT GREEN SUBDIVISION DesiDNED: DRavm: .l a �mlyd,ldam•a°.1 a"��,@°°°•el�"" eNclNEERMSO lor�suc 7IG� RAF JCH �°airrmma°°or.ym°m www.ContechES.com CHECKED: APPROVED: ""°o ix°' °°' m "M"' ° SPS PAC uI.1d ;d" �p 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45W9 CONTRACT Win;&`"- a�a°a rm�r„�arnng°o naoonm m..as, a.mmw�am 800-338-1122 5136157000 513E4S7993 FAX ALBEMARLE COUNTY, VIRGINIA SHEET NO.: °mre�mmm m,:°n mn"moor.. MARK DATE REVISION DESCRIPTION BV oluwiNc CT3 oP CT9 J J mLL 'D (0843) 43'-0" SPAN PRECAST BRIDGE UNIT _Wn a � 0 1 DETAIL rJj - TIE ROD N \ \, ' "X , PRECAST WINGWALL CT2 �' FLOW LINE REINFORCING NOT ' �' m m SHOWN FOR CLARITY O LL M N 9 5'-DYs'"MAX. �-I ir7: SECTION A 0 2• 4• e' CT2 4"6 WEEPHOLE TYPE A, B OR C WINGWALL ANCHOR F _ �= O ' BACKFILLPER ¢ O 4 C7 CON/SPAN® 1•-4' SPECIFICATIONS 3'-2" GROUT TO TOP INSIDE FACE OF �.— SEE TYPICAL WINGWALL (�' -0 OF KEYWAY pRECAST BRIDGE UNIT GROUT UNDER ` ° GROUT DETAIL ON THIS SHEET GROUT UNIT LEG q 2-#6 EACH FACE #5 @ 6,. O.C. ° y NOTE: 1 I� #5 TIES @6"O.C. FILL ENTIRE KEYWAY INCLUDING ~ 10" INSIDE FACE OF NOMINAL 1"VOID BETWEEN BOTTOM OF Y PRECAST BRIDGE UNIT KEYWAY AND BOTTOM OF PRECAST F 4 - #6 TOP &BOTTOM 3, &„ io [0 BRIDGE UNIT LEG WITH GROUT. ,� HP 12 x 53 PILES 3""9,' SEE TYPICAL BRIDGE UNIT U TYPICAL BRIDGE UNIT GROUT DETAIL,°„ m}bbb z GROUT DETAIL ON THIS SHEET NOT TO SCALE m ' W �a v.m ` °•" ;° 2-#6 EACH FACE WINGWALL g•_g^ 6 SPACES @ - 3 i . ar1 #STIES @6"O.C. F WINGWALL ANCHOR SECTION rB ¢ � 1. 2• 4• CT2 7 - #S TOP &BOTTOM #SUGAR 020 fifi1I9 �0 w J3 ¢in a zoW HP 12 x 53 PILES ° I(fUJUt ITttT A Jk11N. k / ;I GROUT I II - m . I 3:1 BATTERED M1 1 °� ul HIP 12x53PILES II I{iI�IIIIIII °'II'III`I. #5 TIES WINGWALL ,�tkc�k 1 i� lJ---L FOOTING BACKSIDE OF 1'-3" 3'-0"�1'-3" 5-0 FOOTING 1 I NOTES:DETAIL 3:1 BATTERED • MINIMUM 1" GROUT UNDER WINGWALL LEG & HP 12 x 53 PILES ANCHOR STEM. — 00 1� CT4 . AREA BETWEEN WINGWALL FOOTING AND WINGWALL ANCHOR SHALL BE GROUTED 0 0 ♦~3_0^SOLID BEFORE BACKFILL. • FORM BACKSIDE OF FOOTING TO SECTION C DIMENSIONS SHOWN ON FOUNDATION PLAN. 0 1• 2• 4• TYPICAL WINGWALL GROUT DETAIL NOT TO SCALE �� a aarvpn�ane imormamn anam mmv arrvnnp bprovbe �� PRQIECTN.. SEEM No.: DATE: daaro: NTECH' /CON\SPAN. 689029 010 3/10/2022 ....m °,m ma°°a,.nn°m m. p,m,.nn.a.°°..mm .n,wam,a°.1,e,nor�pa°•Dr„ .m a % EM�NEEREOSOLLMONSLLc -SERIES. PLEASANT GREEN SUBDIVISION DesiDNED: JMF DRavm: JCH w CHECKED: APPROVED: ix°' °°' "u; .ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45W9 SPS PAC g'o u' 1°�; CONTRACT ALBEMARLE COUNTY, VIRGINIA 800-338-1122 5136157000 513E4S7993 FAX SHEET NO.: MARK DATE REVISION DESCRIPTION BV rm�r„�a, enpa. na.ae as m�..ap. �,m„�wa�a� -,,n. :°p m ew mna�.. oanwiNc CT4 oP CT9 47'-8" SEE TYPICAL HEADWALL JOINT DETAIL ON THIS SHEET y JOINT T/HEADWALL (TYP)ELEV. 702.50 I I m J— nZ _ 00 I I � I I Fo SEE POST CONNECTION DETAIL ON SHEET CT6 IILz it i -h N L/ T/FOOTING ELEV. 689.31 SEE TYPICAL HEADWALL JOINT DETAIL ON THIS SHEET T/HEADWALL ELEV. 702.00 I I Ali bo o I I ? T T T T 4 m w m a r� r� r� / IIL_H I__� LJ* III III III �// T/FOOTING _ ELEV. 687.95 11 IM �,'.""''"m"IMARKI DATE I REVISION DESCRIPTION I TEMPORARY SHORING BY OTHERS (TYP.) FLOW LINE I /— ELEV. 688.92 TLTIMBER POST OR SGRILLAGE BY OTHERS STEEL SHORE (TYP.) (0843) 43'-0" SPAN UPSTREAM END ELEVATION 0 24' 8 47'-8" HEADWALL— 24'-103/4 /4" JOINT (TYP.) 74-- I a SEE POST CONNECTION DETAIL ON SHEET CT6 TEMPORARY SHORING BY OTHERS (TYP.) FLOW LINE I f— ELEV. 687.56 TLTIMBER POST OR STEEL SHORE (TYP.) GRILLAGE BY OTHERS (0843) 43'-0" SPAN DOWNSTREAM END ELEVATION 0 2' 4' 8' CNTECH' EPWINEMW SOUMOM QC www.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45W9 800-338-1122 513615-7000 513 645-7993 FAX 1 8 T/HEADWALL ELEV. 700.00 ILWINGWALL CONNECTION PLATES t4- _�1rh \ \ I I HP 12 x 53 PILE (TYP.) T/HEADWALL ELEV. 700.50 ILWINGWALL CONNECTION PLATES Zn ?m m yZ$Z$ I N� F rZ o 'S I o I P I I n II ( m T T Tii T T ? 0 Coiimiii V. I � \`\ ili ili Ili I \ \\I I I I HP 12 x 53 PILE (TYP.) MSPAL 6-SERIES.. CONTRACT DRAW NG i SIKAFLEX-1A ELASTOMERIC PRECAST SEALANT OR AN APPROVED HEADWALL EQUAL BY CONTRACTOR BACKER ROD 8" x 8" PIECE OF BY CONTRACTOR JOINT WRAP EACH —117 HEADWALL PIECE Y4" JOINT TYPICAL HEADWALL JOINT DETAIL NOT TO SCALE NOTES: 1. INSTALL TIMBER OR STEEL POSTS TIGHT AGAINST UNDERSIDE OF PRECAST ARCH UNIT PRIOR TO SETTING PRECAST HEADWALL UNITS. 2. POSTS SHALL REMAIN IN PLACE UNTIL BACKFILL IS AT LEAST V-0" FROM TOP OF STRUCTURE. 3�W_ Y z �` PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA OIECTNo.:No.: DATE: 689029 010 3/10/2022 eIDNED: DRAM: JMF JCH ECKEO: APPROVED: SPS PAC OF PRECAST WINGWALL PRIMER COMPATIBLE WITH JOINT WRAP T/e' x 1%" BUTYL ROPE TOP OF PRECAST 9" WIDE JOINT WRAP BRIDGE UNIT i PRECAST BRIDGE UNIT TYPICAL JOINT SEAL DETAIL NOT TO SCALE 10"DETACHED BRIDGE LIMITS = 71'-11%" HEADWALL (TYP) SEE TYPICAL JOINT SEAL —DETAIL e� DETAIL ON THIS SHEET CT7 P. BETWEEN UNITS) FLOW LINE • ELEV. 688.92 L,mm,7LJ I 1. 89%S OPT_ II II II II II IT IT II II II II II II II II II II II II II II II II II II II II II SECTION D CT2 PRECAST ARCH UNIT 10" JOINT SEAL BETWEEN END UNIT AND HEADWALL (TYP.) PRECAST HEADWALL FLOW LINE ELEV. 687.56 HP 12 x 53 PILE (TYP.) PRECAST PRECAST `,:fk:r.:{..a-.'. ARCH UNIT STEEL ANGLE STEEL ANGLE 5%.. REMOVABLE EXPANSION TIMBER POST OR TIMBER BLOCKING ANCHOR (FIELD DRILL) REMOVABLE EXPANSION CUT TO BEAR, W/STEEL POST SHORE THRU BOLT ANCHOR (FIELD DRILL) (TYP.) TIMBER POST OR TIMBER BLOCKING THRU BOLT (TYP.) CUT TO BEAR, W/STEEL POST SHORE POST CONNECTION DETAIL HEADWALL SECTION TEMPORARY SHORING DETAIL & SECTION o � o nrvpn�an°mormavon—m..m r. r.— PRQIECTNo.: SEMNo.: DATE: ' "q °�'�' . reap a he: ��.P'.:11 /CONsp� 689029 010 3/10/2022 m °aro:lyw :°ran�ar C NTECH' °,m ma°°or.nn°m m. Prmr.nn.a.°°..mm C PLEASANT GREEN SUBDIVISION DesiDNED: DRavm: �ml.m,wam,.°.ne,no,�°a°•Dr„I .l a ENGINEERMSOWTIONSuc `y}L 7IG� JMF JCH ww v.ContechES.com CHECKED: APPROVED: ""°o ° SPS PAC �,'p°'"M"' 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45W9 CONTRACT a�a°a rm�r„gar nnga. na.anm m�..as, �,.mmwa�am """°'°- 800-338-1122 5136iS7000 513E4S7993 FAX ALBEMARLE COUNTY, VIRGINIA SHEET NO.: _.,"°"°" °mrem�m m,:°n mn"moor.. MARK DATE REVISION DESCRIPTION BY oanwiNc CT6 oP CT9 NOTE: CONNECTION It'S (P-1) MUST BE POSITIONED WITH SMALL 0 HOLES TOWARD PRECAST HEADWALL NOTE: CONNECTION It'S (P-2) MUST BE POSITIONED WITH SMALL 0 HOLES TOWARD PRECAST HEADWALL fL DAYTON SUPERIOR Yy't JOINT 10" 2J" 1t/4"O x 7)'2" F-58 EC INSERT (STAINLESS) Ya'*JOINT 48" DAYTON SUPERIOR TWO BOLT 1t/4"0 x 1'$' COIL ROD (STAINLESS) 10,. LIMITS OF BACKER ROD & 1,-3,r W/ DOUBLE NUT (STAINLESS) rL8" DAYTON SUPERIOR TWO BOLT 10. PRESET ANCHOR FOR 1"0 x 6" CAULK IN HEADWALL WASHER (GALVANIZED) PRESET ANCHOR FOR 1"0 x 6" rL6" DAYTON SUPERIOR TWO BOLT THREADED ROD (2) WITH DOUBLE NUTS JOINT BY CONTRACTOR SPACING TO BE DETERMINED THREADED ROD (2) WITH DOUBLE NUTS 46" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR FOR 1"0 x 6" [ALT. 1"0 x 2s/4" BOLTS, (6" PITCH)] AT SHOP DRAWING STAGE [ALT. 1"0 x 2%" BOLTS, (6" PITCH)] PRESET ANCHOR FOR 1"0 x 6" THREADED ROD (2) WITH DOUBLE NUTS PRECAST HEADWALL 8" WIDE SEALWRAP OR EZ-WRAP THREADED ROD (2) WITH DOUBLE NUTS [ALT. 1"O x 2Y4" BOLTS, (6" PITCH)] PRECAST m u1 � RUBBER AT HEADWALL JOINT FROM [ALT. 1 "0 x 2s/a" BOLTS, (6"PITCH)] PRECAST ., WINGWALL TOP OF ARCH TO FINISH GRADE PRECAST HEADWALL > JOINT WRAP W/PRIMER PRECAST WINGWALL ... ��? HEADWALL gip\ 1"x 147x 10"GALV. R(P-2) PRECAST BRIDGE UNIT '. ;, 370 HOLE GROUT SOLID AFTER 1"x 14" x 10" GALV. ft(P-1) RWASHER 4" x 4" x t/2" 4" INSTALLATION OF COIL ROD ftWASHER 4" x 4" xy2" GALV. (PW-1) 4y" GALV. (PW-1) DETAIL 2 D t• 2• 4' GT6 vy ^o PRECAST WINGWALL IL8" DAYTON SUPERIOR TWO BOLT PRESET ANCHOR FOR 1"O x 6" THREADED ROD (2) WITH DOUBLE NUTS [ALT. 1 "0 x 23/4" BOLTS, (6" PITCH)] PRECAST W NGWALL ftWASHER 4" x 4" x tie" GALV. (PW-1) 1"x 14" x 10" GALV. ft(P-3) y . DETAIL 5 o t• 2• CT2 DETAIL @HEADWALL 3 o t• 2• CT2 BUTYL ROPE, PRIMER & JOINT WRAP INSTALLED UNDER TIE PLATE :J:� 2'-4-2" It T-9' 2" - 4 - %-0 HOLES I 5/j" x 4" x 2'-4" GALVANIZED 1t(P-4) DETAIL 6 NOT TO SCALE CT7 JOINT WRAP & PRIMER INSTALLED (PV-1) H9a--4 F UNDER TIE PLATE BRIDGE END UNIT IIII I I[pf 114 BRIDGE INTERIOR UNIT IIIIII IIIIP': I I IL8" DAYTON SUPERIOR TWOI V � 1"0 x 9" LONG HILTI KWIK BOLT 3 BOLT PRESET ANCHOR FOR I— Z EXPANSION ANCHOR OR APPROVED EQUAL. 1"0 x 2Y4" BOLTS, (6" PITCH) O INSTALL IN FIELD DRILLED HOLES W/ MINIMUM W/ ROUND WASHERS 6" EMBEDMENT, AS PER MANUFACTURER'S BUTYL ROPE INSTALLATION INSTRUCTIONS(T/P.) SECTION D NOT TO SCALE CT7 DETAIL @HEADWALL 4 0 1. 2• CT2 n rvpn�an°mormavon—mmy—r vr.— �� PRQIECTNo.: SEMN- DATE: "' ' "q °�'�' .area, a w e: 688028 010 3/10/2022 a°aro: ar C NTECH' / 00 0N\$PAIN. m. y,m, wnn.n •onaemm PLEASANT GREEN SUBDIVISION DESIGNED: DRANM: .l a �ml.m,wam,a°.ne,no,m°°°•Dr„ 1EMINEERMSOIUiIOM I�� RAF JCH �n,Iumt,nar.im°,n www.ContechES.com CHECKED: APPROVED: ""°o g'o ix°' °°' m "M"' ° SPS PAC uI.1d-d" 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45W9 CONTRACT °"°"°" a�a°a rm�r„�a,nng°o moon m, m.was, o,mmw�am 800-338-1122 5136157000 513E4S7993 FAX ALBEMARLE COUNTY, VIRGINIA SHEET NO.: °„re,mmm m,:°n mn"moor.. MARK DATE REVISION DESCRIPTION BV oluwiNc CT] oP CT9 SPECIFICATIONS FOR MANUFACTURE AND INSTALLATION OF CON/SPAN® O-SERIES BRIDGE SYSTEMS 1. DESCRIPTION 1.1. TYPE- THIS WORK SHALL CONSIST OF FURNISHING AND CONSTRUCTING A CONISPAN® CSERIES BRIDGE SYSTEM IN ACCORDANCE WITH THESE SPECIFICATIONS AND IN REASONABLY CLOSE CONFORMITY WITH THE LINES, GRADES, DESIGN AND DIMENSIONS SHOWN ON THE PUNS OR AS ESTABLISHED BY THE ENGINEER. IN SITUATIONS "ERE TWO OR MORE SPECIFICATIONS APPLY TO THIS WORK, THE MOST STRINGENT REQUIREMENTS SHALL GOVERN. 1.2. DESIGNATION- PRECAST REINFORCED CONCRETE CONSPAN® OSERIES BRIDGE UNITS MANUFACTURED IN ACCORDANCE WITH THIS SPECIFICATION SHALL BE DESIGNATED BY SPAN AND RISE. PRECAST REINFORCED CONCRETE WINGWALLS AND HEADWALLS MANUFACTURED IN ACCORDANCE WITH THIS SPECIFICATION SHALL BE DESIGNATED BY LENGTH, HEIGHT, AND DEFLECTION ANGLE. PRECAST REINFORCED CONCRETE EXPRESS- FOUNDATION UNITS MANUFACTURED IN ACCORDANCE WITH THIS SPECIFICATION SHALL BE DESIGNATED BY LENGTH, HEIGHT AND WIDTH. 2. DESIGN 21. SPECIFICATIONS- THE PRECAST ELEMENTS ARE DESIGNED IN ACCORDANCE WITH THE 'AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS' 8TH EDITION, ADOPTED BY THE AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS, 201T A MINIMUM OF ONE FOOT OF COVER ABOVE THE CROWN OF THE BRIDGE UNITS IS REQUIRED IN THE INSTALLED CONDITION. (UNLESS NOTED OTHERWISE ON THE SHOP DRAWINGS AND DESIGNED ACCORDINGLY) 3. MATERIALS 3.1. CONCRETE -THE CONCRETE FOR THE PRECAST ELEMENTS SHALL BE AIR -ENTRAINED WHEN INSTALLED IN AREAS SUBJECT TO FREEZE -THAW CONDITIONS, COMPOSED OF PORTLAND CEMENT, FINE AND COARSE AGGREGATES, ADMIXTURES AND WATER. AIR -ENTRAINED CONCRETE SHALL CONTAIN 642 PERCENT AIR. THE AIR- ENTRAINING ADMIXTURE SHALL CONFORM TO AASHT0 M1St. SHOWN ON THE SHOP DRAWINGS. 3.1.1.1PORTLAND CEMENT- SHALL CONFORM TO THE REQUIREMENTS OF ASTM SPECIFICATIONS C150-TYPE I, TYPE II, OR TYPE III CEMENT. 3.1.2.COARSE AGGREGATE -SHALL CONSIST OF STONE HAVING A MAXIMUM SIZE OF 1 INCH. AGGREGATE SHALL MEET REQUIREMENTS FOR ASTM C33. 3.1.3. WATER REDUCING ADMIXTURE -THE MANUFACTURER MAY SUBMIT, FOR APPROVAL BY THE ENGINEER, A WATER -REDUCING ADMIXTURE FOR THE PURPOSE OF INCREASING WORKABILITY AND REDUCING THE WATER REQUIREMENT FOR THE CONCRETE. 3.1.4.CALCIUM CHLORIDE -THE ADDITION TO THE MIX OF CALCIUM CHLORIDE OR ADMIXTURES CONTAINING CALCIUM CHLORIDE WILL NOT BE PERMITTED. 3.1.5.MIXTURE - THE AGGREGATES, CEMENT AND WATER SHALL BE PROPORTIONED AND MIXED IN A BATCH MWER TO PRODUCE A HOMOGENEOUS CONCRETE MEETING THE STRENGTH REQUIREMENTS OF THIS SPECIFICATION. THE PROPORTION OF PORTLAND CEMENT IN THE MIXTURE SHALL NOT BE LESS THAN 566 POUNDS I6 SACKS) PER CUBIC YARD OF CONCRETE. 3.2. STEEL REINFORCEMENT 3.2.1.THE MINIMUM STEEL YIELD STRENGTH SHALL BE 60,000 PSI, UNLESS OTHERWISE NOTED ON THE SHOP DRAWINGS. 12.Z ALL REINFORCING STEEL FOR THE PRECAST ELEMENTS SHALL BE FABRICATED AND PLACED IN ACCORDANCE WITH THE DETAILED SHOP DRAWINGS SUBMITTED BY THE MANUFACTURER. 3.2.3.REINFORCEMENT SHALL CONSIST OF WELDED WIRE REINFORCING CONFORMING TO ASTM SPECIFICATION A 1064, OR DEFORMED STEEL BARS CONFORMING TO ASTM SPECIFICATION A 615, GRADE 60. LONGITUDINAL DISTRIBUTION REINFORCEMENT MAY CONSIST OF WELDED WIRE FABRIC OR DEFORMED BILLET -STEEL BARS. 3.3. STEEL HARDWARE 3.3.1.BOLTS AND THREADED ROBS FOR WINGWALL CONNECTIONS SHALL CONFORM TO ASTM A 30T NUTS SHALL CONFORM TO AASHTO M292 (A5TM AlW) GRADE 2H. ALL BOLTS, THREADED RODS AND NUTS USED IN WINGWALL CONNECTIONS SHALL BE MECHANICALLY ZINC COATED IN ACCORDANCE WITH ASTM B695 CLASS50. 3.3.2. STRUCTURAL STEEL FOR WINGWALL CONNECTION PLATES AND PLATE WASHERS SHALL CONFORM TO AASHTO M 270 (ASTM A 709) GRADE 36 AND SHALL BE HOT DIP GALVANIZED AS PER AASHTO M111 (ASTM A123). 3.3.3.INSERTS FOR WINGWALLS SHALL BE 1" DIAMETER TWO -BOLT PRESET WINGWALL ANCHORS AS MANUFACTURED DAYTON SUPERIOR CONCRETE ACCESSORIES, MIAMISBURG, OHIO, (800) 7453700 AND SHALL BE ELECTRO GALVANIZED IN ACCORDANCE WITH ASTM 13633 SC-1. 3.3.4.FERRULE LOOP INSERTS SHALL BE FS4 FERRULE LOOP INSERTS AS MANUFACTURED BY DAYTON SUPERIOR CONCRETE ACCESSORIES, MIAMISBURG, OHIO, (800) 7453700 AND SHALL BE ELECTRO GALVANIZED. 3.3.5.INSERTS FOR DETACHED HEADWALL CONNECTIONS SHALL BE AISI TYPE 304 STAINLESS STEEL, EXPANDED COIL INSERTS AS MANUFACTURED BY DAYTON SUPERIOR CONCRETE ACCESSORIES, MIAMISBURG, OHIO, (800) 7453700. COIL RODS AND NUTS USED IN HEADWALL CONNECTIONS SHALL BE AISI TYPE 304 STAINLESS STEEL. WASHERS USED IN HEADWALL CONNECTIONS SHALL BE EITHER AISI TYPE 304 STAINLESS STEEL PLATE WASHERS OR AASHTO W70 (ASTM A709) GRADE 36 PLATE WASHERS HOT DIP GALVANIZED AS PER AASHTO Ml 11 (ASTM A123L 3.3S.MECHANICAL SPLICES OF REINFORCING BARS SHALL BE MADE USING THE DOWEL BAR SPLICER SYSTEM AS MANUFACTURED BY DAYTON SUPERIOR CONCRETE ACCESSORIES, MIAMISBURG, OHIO, (800) 745-3700, AND SHALL CONSIST OF THE DBDI SPLICE SYSTEM (DOWEL BAR SPLICER AND DOWEL -IN), OR AS MANUFACTURED BY MRSPLICE PRODUCTS INC, DAYTON, OHIO, (937)-27"700, AND SHALL CONSIST OF BARSPLICER XP TYPE 2 SYSTEM. 4. MANUFACTURE OF PRECAST ELEMENTS- SUBJECT TO THE PROVISIONS OF SECTION 5, BELOW, THE PRECAST ELEMENT DIMENSION AND REINFORCEMENT DETAILS SHALL BE AS PRESCRIBED IN THE PLAN AND SHOP DRAWINGS PROVIDED BY THE MANUFACTURER. 4A. FORMS -THE FORMS USED IN MANUFACTURE SHALL BE SUFFICIENTLY RIGID AND ACCURATE TO MAINTAIN THE REQUIRED PRECAST ELEMENT DIMENSIONS WITHIN THE PERMISSIBLE VARIATIONS GIVEN IN SECTION 5OF THESE SPECIFICATIONS. ALL CASTING SURFACES SHALL BE OF A SMOOTH MATERIAL. 4.2. PLACEMENT OF REINFORCEMENT 4.2.1. PLACEMENT OF REINFORCEMENT IN PRECAST BRIDGE UNITS - THE COVER OF CONCRETE OVER THE OUTSIDE CIRCUMFERENTIAL REINFORCEMENT SHALL BE 2" MINIMUM. THE COVER OF CONCRETE OVER THE INSIDE CIRCUMFERENTIAL REINFORCEMENT SHALL BE I& MINIMUM, UNLESS OTHERWISE NOTED ON THE SHOP DRAWINGS. THE CLEAR DISTANCE OF THE END CIRCUMFERENTIAL WIRES SHALL NOT BE LESS THAN 1' NOR MORE THAN 2' FROM THE ENDS OF EACH SECTION. REINFORCEMENT SHALL BE ASSEMBLED UTILIZING SINGLE OR MULTIPLE LAYERS OF WELDED WIRE FABRIC (NOT TO EXCEED 3 LAYERS), SUPPLEMENTED WITH A SINGLE LAYER OF DEFORMED BILLET -STEEL BARS, WHEN NECESSARY. WELDED WIRE FABRIC SHALL BE COMPOSED OF CIRCUMFERENTIAL AND LONGITUDINAL WIRES MEETING THE SPACING REQUIREMENTS OF 4.3, BELOW, AND SHALL CONTAIN SUFFICIENT LONGITUDINAL WIRES EXTENDING THROUGH THE BRIDGE UNIT TO MAINTAIN THE SHAPE AND POSITION OF THE REINFORCEMENT. LONGITUDINAL DISTRIBUTION REINFORCEMENT MAY BE WELDED WIRE FABRIC OR DEFORMED BILLETSTEEL BARS AND SHALL MEET THE SPACING REQUIREMENTS OF 4.3. BELOW. THE ENDS OF THE LONGITUDINAL DISTRIBUTION REINFORCEMENT SHALL BE NOT MORE THAN 3" AND NOT LESS THAN 1%" FROM THE ENDS OF THE BRIDGE UNIT. 4.2.2. BENDING OF REINFORCEMENT FOR PRECAST BRIDGE UNITS - THE OUTSIDE AND INSIDE CIRCUMFERENTIAL REINFORCING STEEL FOR THE CORNERS OF THE BRIDGE SHALL BE BENT TO SUCH AN ANGLE THAT IS APPROXIMATELY EQUAL TO THE CONFIGURATION OF THE BRIDGES OUTSIDE CORNER. 4.2.3. PLACEMENT OF REINFORCEMENT FOR PRECAST WINGWALLS AND HEADWALLS -THE COVER OF CONCRETE OVER THE LONGITUDINAL AND TRANSVERSE REINFORCEMENT SHALL BE 2" MINIMUM. THE CLEAR DISTANCE FROM THE END OF EACH PRECAST ELEMENT TO THE END OF REINFORCING STEEL SHALL NOT BE LESS THAN 1 W NOR MORE THAN 3'. REINFORCEMENT SHALL BE ASSEMBLED UTILIZING A SINGLE LAYER OF WELDED WIRE FABRIC, OR A SINGLE LAYER OF DEFORMED BILLET -STEEL BARS. WELDED WIRE FABRIC SHALL BE COMPOSED OF TRANSVERSE AND LONGITUDINAL WIRES MEETING THE SPACING REQUIREMENTS OF 4.3, BELOW, AND SHALL CONTAIN SUFFICIENT LONGITUDINAL WIRES EXTENDING THROUGH THE ELEMENT TO MAINTAIN THE SHAPE AND POSITION OF THE REINFORCEMENT. LONGITUDINAL REINFORCEMENT MAY BE WELDED WIRE FABRIC OR DEFORMED BILLETSTEEL BARS AND SHALL MEET THE SPACING REQUIREMENTS OF 4.3, BELOW. 4.2.4. PLACEMENT OF REINFORCMENT FOR PRECAST FOUNDATION UNITS -THE COVER OF CONCRETE OVER THE BOTTOM REINFORCEMENT SHALL BE 3INCHES MINIMUM. THE COVER OF CONCRETE FOR ALL OTHER REINFORCEMENT SHALL BE 2 INCHES MINIMUM. THE CLEAR DISTANCE FROM THE END OF EACH PRECAST ELEMENT TO THE END OF REINFORCING STEEL SHALL NOT BE LESS THAN 2INCHES NOR MORE THAN 3INCHES. REINFORCEMENT SHALL BE ASSEMBLED UTILIZING A SINGLE LAYER OF WELDED WIRE FABRIC OR A SINGLE LAYER OF DEFOREMED BILLET -STEEL BARS. WELDED WIRE FABRIC SHALL BE COMPOSED OF TRANSVERSE AND LONGITUDINAL WIRES MEETING THE SPACING REQUIREMENTS OF 4.3, BELOW, AND SHALL CONTAIN SUFFICIENT LONGITUDINAL WIRES EXTENDING THROUGH THE ELEMENT TO MAINTAIN THE SHAPE AND POSITION OF THE REINFORCEMENT. LONGITUDINAL REINFORCEMENT MAY BE WELDED WIRE FABRIC OR DEFORMED BILLET -STEEL BARS AND SHALL MEET THE SPACING REQUIREMENTS OF 4.3, BELOW. 4.3. LAPS WELDS, SPACING 4.3.1. LAPS WELDS, AND SPACING FOR PRECAST BRIDGE UNITS - TENSION SPLICES IN THE CIRCUMFERENTIAL REINFORCEMENT SHALL BE MADE BY LAPPING. LAPS MAY BE TACK WELDED TOGETHER FOR ASSEMBLY PURPOSES. FOR SMOOTH WELDED WIRE FABRIC, THE OVERLAP SHALL MEET THE REQUIREMENTS OF AASHTO 5.10.81.513 AND 5.10.8.5.2. FOR DEFORMED WELDED WIRE FABRIC, THE OVERLAP SHALL MEET THE REQUIREMENTS OF AASHTO S.10.83.5A AND SA0.8.5.1. THE OVERLAP OF WELDED WIRE FABRIC SHALL BE MEASURED BETWEEN THE OUTER -MOST LONGITUDINAL WIRES OF EACH FABRIC SHEET. FOR DEFORMED BILLET -STEEL BARS, THE OVERLAP SHALL MEET THE REQUIREMENTS OF AASHTO 5.10.81.1 FOR SPLICES OTHER THAN TENSION SPLICES, THE OVERLAP SHALL BE A MINIMUM OF 1'-0" FOR WELDED WIRE FABRIC OR DEFORMED BILLETSTEEL BARS. THE SPACING CENTER TO CENTER OF THE CIRCUMFERENTIAL WIRES IN A WIRE FABRIC SHEET SHALL BE NOT LESS THAN T NOR MORE THAN 4". THE SPACING CENTER TO CENTER OF THE LONGITUDINAL WIRES SHALL NOT BE MORE THAN W. THE SPACING CENTER TO CENTER OF THE LONGITUDINAL DISTRIBUTION STEEL FOR EITHER LINE OF REINFORCING IN THE TOP SLAB SHALL BE NOT MORE THAN 1'4'. 4.3.2. LAPS WELDS, AND SPACING FOR PRECAST WINGWALLS, HEADWALLS AND FOUNDATIONS -SPLICES IN THE REINFORCEMENT SHALL BE MADE BY LAPPING. LAPS MAY BE TACK WELDED TOGETHER FOR ASSEMBLY PURPOSES. FOR SMOOTH WELDED WIRE FABRIC, THE OVERLAP SHALL MEET THE REQUIREMENTS OF AASHTO S.10.81.513 AND SAB8.5.2. FOR DEFORMED WELDED WIRE FABRIC, THE OVERLAP SHALL MEET THE REQUIREMENTS OF AASHTO 5.10.8.2.5A AND SAB8.5.1. FOR DEFORMED BILLET -STEEL BARS, THE OVERLAP SHALL MEET THE REQUIREMENTS OF AASHTO 5.10.8.2.1. THE SPACING DATE I REVISION DESCRIPTION CENTER -TO -CENTER OF THE WIRES IN A WIRE FABRIC SHEET SHALL BE NOT LESS THAN 2' NOR MORE THAN W. 44. CURING- THE PRECAST CONCRETE ELEMENTS SHALL BE CURED FOR A SUFFICIENT LENGTH OF TIME SO THAT THE CONCRETE WILL DEVELOP THE SPECIFIED COMPRESSIVE STRENGTH IN 28 DAYS OR LESS. ANY ONE OF THE FOLLOWING METHODS OF CURING OR COMBINATIONS THERE OF SHALL BE USED: 4A.1.SMAM CURING -THE PRECAST ELEMENTS MAY BE LOW-PRESSURE STEAM CURED BY A SYSTEM THAT WILL MAINTAIN A MOIST ATMOSPHERE. 4A.2. WATER CURING -THE PRECAST ELEMENTS MAY BE WATER CURED BY MY METHOD THAT WILL KEEP THE SECTIONS MOIST. 4A.3. MEMBRANE CURING -A SEALING MEMBRANE CONFORMING TO THE REQUIREMENTS OF ASTM SPECIFICATION C309 MAY BE APPLIED AND SHALL BE LEFT INTACT UNTIL THE REQUIRED CONCRETE COMPRESSIVE STRENGTH IS ATTAINED. THE CONCRETE TEMPERATURE AT THE TIME OF APPLICATION SHALL BE WITHIN +/-10 DEGREES F OF THE ATMOSPHERIC TEMPERATURE. ALL SURFACES SHALL BE KEPT MOIST PRIOR TO THE APPLICATION OF THE COMPOUNDS AND SHALL BE DAMP WHEN THE COMPOUND IS APPLIED. 4.5. STORAGE, HANDLING & DELIVERY 4.5.1. STORAGE - PRECAST CONCRETE BRIDGE ELEMENTS SHALL BE LIFTED AND STORED IN "ASL POSITION. PRECAST CONCRETE HEADWALL AND WINGWALL UNITS ARE CAST, STORED AND SHIPPED IN A FLAT POSITION. THE PRECAST ELEMENTS SHALL BE STORED IN SUCH A MANNER TO PREVENT CRACKING OR DAMAGE. STORE ELEMENTS USING TIMBER SUPPORTS AS APPROPRIATE. THE UNITS SHALL NOT BE MOVED UNTIL THE CONCRETE COMPRESSIVE STRENGTH HAS REACHED A MINIMUM OF 2500 PSI (3000 PSI FOR SPANS � FEET), AND THEY SHALL NOT BE STORED IN AN UPRIGHT POSITION. 4.5.2. HANDLING- HANDLING DEVICES SHALL BE PERMITTED IN EACH PRECAST ELEMENT FOR THE PURPOSE OF HANDLING AND SETTING. SPREADER BEAMS MAY BE REQUIRED FOR THE LIFTING OF PRECAST CONCRETE BRIDGE ELEMENTS TO PRECLUDE DAMAGE FROM BENDING OR TORSION FORCES. 4.5.3. DELIVERY- PRECAST CONCRETE ELEMENTS MUST NOT BE SHIPPED UNTIL THE CONCRETE HAS ATTAINED THE SPECIFIED DESIGN COMPRESSIVE STRENGTH, OR AS DIRECTED BY THE DESIGN ENGINEER. PRECAST CONCRETE ELEMENTS MAY BE UNLOADED AND PLACED ON THE GROUND AT THE SITE UNTIL INSTALLED. STORE ELEMENTS USING TIMBER SUPPORTS AS APPROPRIATE. 4.6. QUALITY ASSURANCE- THE PRECASTER SHALL DEMONSTRATE ADHERENCE TO THE STANDARDS SET FORTH IN THE NPCA QUALITY CONTROL MANUAL. THE PRECASTER SHALL MEET EITHER SECTION 4e.1 OR 4.6.2 4.6.1. CERTIFICATION -THE PRECASTER SHALL BE CERTIFIED BY THE PRECASTIPRESTRESSED CONCRETE INSTITUTE PLANT CERTIFICATION PROGRAM OR THE NATIONAL PRECAST CONCRETE ASSOCIATION'S PLANT CERTIFICATION PROGRAM PRIOR TO AND DURING PRODUCTION OF THE PRODUCTS COVERED BY THIS SPECIFICATION. 4.6.2. QUALIFICATIONS TESTING AND INSPECTION 4.6.2.1. THE PRECASTER SHALL HAVE BEEN IN THE BUSINESS OF PRODUCING PRECAST CONCRETE PRODUCTS SIMILAR TO THOSE SPECIFIED FOR A MINIMUM OF THREE YEARS. HE SHALL MAINTAIN A PERMANENT QUALITY CONTROL DEPARTMENT OR RETAIN AN INDEPENDENT TESTING AGENCY ON A CONTINUING BASIS. THE AGENCY SHALL ISSUE A REPORT, CERTIFIED BY LICENSED ENGINEER, DETAILING THE ABILITY OF THE PRECASTER TO PRODUCE QUALITY PRODUCTS CONSISTENT WITH INDUSTRY STANDARDS. 4.6.2.2. THE PRECASTER SHALL SHOW THAT THE FOLLOWNG TESTS ARE PERFORMED IN ACCORDANCE WITH THE ASTM STANDARDS INDICATED. TESTS SHALL BE PERFORMED AS INDICATED IN SECTION 6 OF THESE SPECIFICATIONS. 4.61.2.1. AIR CONTENT: U31 OR C173 4.61.21. COMPRESSIVE STRENGTH: C31,C39,C497 4.6.2.3. THE PRECASTER SHALL PROVIDE DOCUMENTATION DEMONSTRATING COMPLIANCE WITH THIS SECTION TO CONTECHO ENGINEERED SOLUTIONS AT REGULAR INTERVALS OR UPON REQUEST. 4.6.2.4. THE OWNER MAY PLACE AN INSPECTOR IN THE PLANT WHEN THE PRODUCTS COVERED BY THIS SPECIFICATION ARE BEING MANUFACTURED. 4.6.3. DOCUMENTATION -THE PRECASTER SHALL SUBMIT PRECAST PRODUCTION REPORTS TO CONTECHT) ENGINEERED SOLUTIONS AS REQUIRED. 5. PERMISSIBLE VARATIONS Sl1 BRIDGE UNITS 5.1.1.INTERNAL DIMENSIONS -THE INTERNAL DIMENSION SHALL VARY NOT MORE THAN 1% FROM THE DESIGN DIMENSIONS NOR MORE THAN US- WHICHEVER IS LESS. 5.13. SLAB AND WALL THICKNESS -THE SLAB AND WALL THICKNESS SHALL NOT BE LESS THAN THAT SHOWN IN THE DESIGN BY MORE THAN Ya A THICKNESS MORE THAN THAT REQUIRED IN THE DESIGN SHALL NOT BE CAUSE FOR REJECTION. 5.1.3. LENGTH OF OPPOSITE SURFACES - VARIATIONS IN LAYING LENGTHS OF TWO OPPOSITE SURFACES OF THE BRIDGE UNIT SHALL NOT BE MORE THAN),' IN ANY SECTION, EXCEPT WHERE BEVELED ENDS FOR LAYING OF CURVES ARE SPECIFIED BY THE PURCHASER. 5.1 A. LENGTH OF SECTION -THE UNDERRUN IN LENGTH OF A SECTION SHALL NOT BE MORE THAN)," IN ANY BRIDGE UNIT. 5.1.5. POSITION OF REINFORCEMENT -THE MAXIMUM VARIATION IN POSITION OF THE REINFORCEMENT SHALL BE t),". IN NO CASE SHALL THE COVER OVER THE REINFORCEMENT BE LESS THAN I& FOR THE OUTSIDE CIRCUMFERENTIAL STEEL OR BE LESS THAN V FOR THE INSIDE CIRCUMFERENTIAL STEEL AS MEASURED TO THE EXTERNAL OR INTERNAL SURFACE OF THE BRIDGE. THESE TOLERANCES OR COVER REQUIREMENTS DO NOT APPLY TO MATING SURFACES OF THE JOINTS. 5 L6. AREA OF REINFORCEMENT- THE AREAS OF STEEL NTECH0 ENGImam Solui m LLC www.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 800-338-1122 513615-7000 513 6457993 FAX CONTRACT DRAWING REINFORCEMENT SHALL BE THE DESIGN STEEL AREAS AS SHOWN IN THE MANUFACTURER'S SHOP DRAWINGS. STEEL AREAS GREATER THAN THOSE REQUIRED SHALL NOT BE CAUSE FOR REJECTION. THE PERMISSIBLE VARIATION IN DIAMETER OF ANY REINFORCEMENT SHALL CONFORM TO THE TOLERANCES PRESCRIBED IN THE ASTM SPECIFICATION FOR THAT TYPE OF REINFORCEMENT. 5.2. WINGWALLS&HEADWALLS 5.2A. WALL THICKNESS- THE WALL THICKNESS SHALL NOT VARY FROM THAT SHOWN IN THE DESIGN BY MORE THAN)4". 5.2.2. LENGTHIHEIGHT OF WALL SECTIONS -THE LENGTH AND HEIGHT OF THE WALL SHALL NOT VARY FROM THAT SHOWN IN THE DESIGN BY MORE THAN),'. 5.2.3. POSITION OF REINFORCEMENT -THE MAXIMUM VARIATION IN THE POSITION OF THE REINFORCEMENT SHALL BE 4)V. IN NO CASE SHALL THE COVER OVER THE REINFORCEMENT BE LESS THAN 1),". 5.2A.SIZE OF REINFORCEMENT -THE PERMISSIBLE VARIATION IN DIAMETER OF ANY REINFORCING SHALL CONFORM TO THE TOLERANCES PRESCRIBED IN THE ASTM SPECIFICATION FOR THAT TYPE OF REINFORCING. STEEL AREA GREATER THAN THAT REQUIRED SHALL NOT BE CAUSE FOR REJECTION. 5.3. FOUNDATION UNITS SSA. WALL THICKNESS -THE WALL THICKNESS SHALL NOT VARY FROM THAT SHOWN IN THE DESIGN BY MORE THAN V. 5.3.2. LENGTH/ HEIGHTAMDTH OF FOUNDATION SECTIONS -THE LENGTH, HEIGHT AND WIDTH OF THE FOUNDATION UNITS SHALL NOT VARY FROM THAT SHOWN IN THE DESIGN BY MORE THAN Yt". 5.3.3. POSITION OF REINFORCEMENT -THE MAXIMUM VARIATION IN THE POSITION OF THE REINFORCEMENT SHALL BE t4". IN NO CASE SHALL THE COVER OVER THE REINFORCEMENT BE LESS THAN 1),". 5.3A.SIZE OF REINFORCEMENT -THE PERMISSIBLE VARIATION IN DIAMETER OF ANY REINFORCING SHALL CONFORM TO THE TOLERANCES PRESCRIBED IN THE ASTM SPECIFICATION FOR THAT TYPE OF REINFORCING. STEEL AREA GREATER THAN THAT REQUIRED SHALL NOT BE CAUSE FOR REJECTION. 6. TESTING! INSPECTION 6.1. TESTING &1.1. TYPE OF TEST SPECIMEN -CONCRETE COMPRESSIVE STRENGTH SHALL BE DETERMINED FROM COMPRESSION TESTS MADE ON CYLINDERS OR CORES. FOR CYLINDER TESTING, A MINIMUM OF 4 CYLINDERS SHALL BE TAKEN FOR EACH BRIDGE ELEMENT. FOR CORE TESTING, A MINIMUM OF 2 CORES SHALL BE TAKEN FOR EACH BRIDGE ELEMENT. EACH ELEMENT SHALL BE CONSIDERED SEPARATELY FOR THE PURPOSE OF TESTING AND ACCEPTANCE. 6.1.2. COMPRESSION TESTING -CYLINDERS SHALL BE MADE AND TESTED AS PRESCRIBED BY THE ASTM C39 SPECIFICATION. CYLINDERS SHALL BE CURED IN THE SAME ENVIRONMENT AS THE BRIDGE ELEMENTS. CORES SHALL BE OBTAINED AND TESTED FOR COMPRESSIVE STRENGTH FROM EACH ELEMENT IN ACCORDANCE WITH THE PROVISIONS OF THE ASTM C42 SPECIFICATION. 6A.3. ACCEPTABILITY OF CYLINDER TESTS -WHEN THE AVERAGE COMPRESSIVE STRENGTH OF ALL CYLINDERS TESTED IS EQUAL TO OR GREATER THAN THE DESIGN COMPRESSIVE STRENGTH, AND NOT MORE THAN 10%OF THE CYLINDERS TESTED HAVE A COMPRESSIVE STRENGTH LESS THAN THE DESIGN CONCRETE STRENGTH, AND NO CYLINDER TESTED HAS A COMPRESSIVE STRENGTH LESS THAN 90%OF THE REQUIRED CONCRETE STRENGTH, THEN THE ELEMENT SHALL BE ACCEPTED. MEN THE COMPRESSIVE STRENGTH OF THE CYLINDERS TESTED DOES NOT CONFORM TO THESE ACCEPTANCE CRITERIA, THE ACCEPTABILITY OF THE ELEMENT MAY BE DETERMINED AS DESCRIBED IN SECTION 6.1.4, BELOW. 6.1.4.ACCEPTABILITY OF CORE TESTS-THECOMPRESSIVE STRENGTH OF THE CONCRETE IN A BRIDGE ELEMENT IS ACCEPTABLE WHEN EACH CORE TEST STRENGTH IS EQUAL TO OR GREATER THAN THE DESIGN CONCRETE STRENGTH. WHEN THE COMPRESSIVE STRENGTH OF A CORE TESTED IS LESS THAN THE DESIGN CONCRETE STRENGTH, THE PRECAST ELEMENT FROM WHICH THAT CORE WAS TAKEN MAY BE RE -CORED. WHEN THE COMPRESSIVE STRENGTH OF THE RE -CORE IS EQUAL TO OR GREATER THAN THE DESIGN CONCRETE STRENGTH, THE COMPRESSIVE STRENGTH OF THE CONCRETE IN THAT BRIDGE ELEMENT IS ACCEPTABLE. 6.1 A.1. WHEN THE COMPRESSIVE STRENGTH OF ANY RECORE IS LESS THAN THE DESIGN CONCRETE STRENGTH, THE PRECAST ELEMENT FROM WHICH THAT CORE WAS TAKEN SHALL BE REJECTED. 6.1.4.2. PLUGGING CORE HOLES -THE CORE HOLES SHALL BE PLUGGED AND SEALED BY THE MANUFACTURER IN A MANNER SUCH THAT THE ELEMENTS WILL MEET ALL OF THE TEST REQUIREMENTS OF THIS SPECIFICATION. PRECAST ELEMENTS SO SEALED SHALL BE CONSIDERED SATISFACTORY FOR USE. 6.1A.3. TEST EQUIPMENT- EVERYMANUFACTURER FURNISHING PRECAST ELEMENTS UNDER THIS SPECIFICATION SHALL FURNISH ALL FACILITIES AND PERSONNEL NECESSARY TO CARRY OUT THE TEST REQUIRED. 6.2. INSPECTION -THE QUALITY OF MATERIALS. THE PROCESS OF MANUFACTURE, AND THE FINISHED PRECAST ELEMENTS SHALL BE SUBJECT TO INSPECTION BY THE PURCHASER. 7. JOINTS THE BRIDGE UNITS SHALL BE PRODUCED WITH FLAT BUTT ENDS. THE ENDS OF THE BRIDGE UNITS SHALL BE SUCH THAT WHEN THE SECTIONS ARE LAID TOGETHER THEY WILL MAKE A CONTINUOUS LINE WITH A SMOOTH INTERIOR FREE OF APPRECIABLE IRREGULARITIES, ALL COMPATIBLE WITH THE PERMISSIBLE VARIATIONS IN SECTION 5, ABOVE. THE JOINT WIDTH BETWEEN ADJACENT PRECAST UNITS SHALL NOT EXCEED Y". 8. WORKMANSHIP! FINISH THE BRIDGE UNITS, WINGWALLS. HEADWALLS AND FOUNDATION UNITS SHALL BE SUBSTANTIALLY FREE OF FRACTURES. THE ENDS OF THE BRIDGE UNITS SHALL BE NORMAL TO THE WALLS AND CENTERLINE OF THE BRIDGE SECTION, WITHIN THE LIMITS OF THE VARIATIONS GIVEN IN SECTION 5, ABOVE, EXCEPT WHERE BEVELED ENDS ARE SPECIFIED. THE FACES OF THE WINGWALLS AND HEADWALLS SHALL BE PARALLEL TO EACH OTHER, WITHIN THE LIMITS OF VARIATIONS GIVEN IN SECTION 5, ABOVE. THE SURFACE OF THE PRECAST ELEMENTS SHALL BE A SMOOTH STEEL FORM OR TROWELED SURFACE. TRAPPED AIR POCKETS CAUSING SURFACE DEFECTS SHALL BE CONSIDERED AS PART OF A SMOOTH, STEEL FORM FINISH. 9. REPAIRS PRECAST ELEMENTS MAY BE REPAIRED, IF NECESSARY, BECAUSE OF IMPERFECTIONS IN MANUFACTURE OR HANDLING DAMAGE AND WILL BE ACCEPTABLE IF, IN THE OPINION OF THE PURCHASER, THE REPAIRS ARE SOUND, PROPERLY FINISHED AND CURED, AND THE REPAIRED SECTION CONFORMS TO THE REQUIREMENTS OF THIS SPECIFICATION. 10.REJECTION THE PRECAST ELEMENTS SHALL BE SUBJECT TO REJECTION ON ACCOUNT OF ANY OF THE SPECIFICATION REQUIREMENTS. INDIVIDUAL PRECAST ELEMENTS MAY BE REJECTED BECAUSE OF ANY OF THE FOLLOWING: 10.1.FRACTURES OR CRACKS PASSING THROUGH THE WALL, EXCEPT FOR A SINGLE END CRACK THAT DOES NOT EXCEED ONE HALF THE THICKNESS OF THE WALL. 10.2.DEFECTS THAT INDICATE PROPORTIONING, MIXING, AND MOLDING NOT IN COMPLIANCE WITH SECTION 4 OF THESE SPECIFICATIONS. 10.3.11ONEYCOMBED OR OPEN TEXTURE. 10.4.DAMAGED ENDS, WHERE SUCH DAMAGE WOULD PREVENT MAKING A SATISFACTORY JOINT. WECTNo. SEMNo, DATE: 689029 010 3/10/2022 PLEASANT GREEN SUBDIVISION y 'JMF JCH CHECKED: APPROVED: SPS PAC ALBEMARLE COUNTY, VIRGINIA SHEET NO.: CT8 DE Cl SPECIFICATIONS FOR MANUFACTURE AND INSTALLATION OF CON/SPAN® O-SERIES BRIDGE SYSTEMS (CONT1 11. MARKING EACH UNIT SHALL BE CLEARLY MARKED BY WATERPROOF PAINT. THE FOLLOWING SHALL BE SHOWN ON THE INSIDE OF THE VERTICAL LEG OF THE BRIDGE SECTION: BRIDGE SPAN x BRIDGE RISE DATE OF MANUFACTURE NAME OR TRADEMARK OF THE MANUFACTURER 1Z INSTALLATION PREPARATION TO ENSURE CORRECT INSTALLATION OF THE PRECAST CONCRETE BRIDGE SYSTEM, CARE AND CAUTION MUST BE EXERCISED IN FORMING THE SUPPORT AREAS FOR BRIDGE UNITS, HEADWALL, AND WINGWAL ELEMENTS. EXERCISING SPECIAL CARE WILL FACILITATE THE RAPID INSTALLATION OF THE PRECAST COMPONENTS. 12A. FOOTINGS DO NOT OVER EXCAVATE FOUNDATIONS UNLESS DIRECTED BY SITE SOIL ENGINEER TO REMOVE UNSUITABLE SOIL. THE SITE SOILS ENGINEER SHALL CERTIFY THAT THE BEARING CAPACITY MEETS OR EXCEEDS THE FOOTING DESIGN REQUIREMENTS, PRIOR TO THE CONTRACTOR POURING OF THE FOOTINGS. THE BRIDGE UNITS AND WINGWALLS SHALL BE INSTALLED ON EITHER PRECAST OR CAST -IN -PLACE CONCRETE FOOTINGS. THE SIZE AND ELEVATION OF THE FOOTINGS SHALL BE AS DESIGNED BY THE ENGINEER. A KEYWAY SHALL BE FORMED IN THE TOP SURFACE OF THE BRIDGE FOOTING AS SPECIFIED ON THE PLANS. NO KEYWAY IS REQUIRED IN THE WINGWALL FOOTINGS, UNLESS OTHERWISE SPECIFIED ON THE PLANS. THE FOOTINGS SHALL BE GIVEN A SMOOTH FLOAT FINISH AND SHALL REACH A COMPRESSIVE STRENGTH OF 2,000 PSI BEFORE PLACEMENT OF THE BRIDGE AND WWGWALL ELEMENTS. BACKFILLING SHALL NOT BEGIN UNTIL THE FOOTING HAS REACHED THE FULL DESIGN COMPRESSIVESTRENGTH. THE FOOTING SURFACE SHALL BE CONSTRUCTED IN ACCORDANCE WITH GRADES SHOWN ON THE PLANS. WHEN TESTED WITH A 10'-0" STRAIGHT EDGE, THE SURFACE SHALL NOT VARY MORE THAN y" IN 104F. IF A PRECAST CONCRETE FOOTING IS USED, THE CONTRACTOR SHALL PREPARE AP THICK BASE LAYER OF COMPACTED GRANULAR MATERIAL THE FULL WIDTH OF THE FOOTING PRIOR TO PLACING THE PRECAST FOOTING. THE FOUNDATIONS FOR PRECAST CONCRETE BRIDGE ELEMENTS AND WINGWALLS MUST BE CONNECTED BY REINFORCEMENT TO FORM ONE MONOLITHIC BODY. EXPANSION JOINTS SHALL NOT BE USED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONSTRUCTION OF THE FOUNDATIONS PER THE PLANS AND SPECIFICATIONS. 13. INSTALLATION 13.1. GENERAL-THEINSTALLATIONOFTHEPRECASTCONCRETE ELEMENTS SHALL BE AS EXPLAINED IN THE PUBLICATION COWMAN BRIDGE SYSTEMS INSTALLATION HANDBOOK. 13.1.1. LIFTING -IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT A CRANE OF THE CORRECT LIFTING CAPACITY IS AVAILABLE TO HANDLE THE PRECAST CONCRETE UNITS. THIS CAN BE ACCOMPLISHED BY USING THE WEIGHTS GIVEN FOR THE PRECAST CONCRETE COMPONENTS AND BY DETERMINING THE LIFTING REACH FOR EACH CRANE UNIT. SITE CONDITIONS MUST BE CHECKED WELL IN ADVANCE OF SHIPPING TO ENSURE PROPER CRANE LOCATION AND TO AVOID MY LIFTING RESTRICTIONS. THE LIFT ANCHORS OR HOLES PROVIDED IN EACH UNIT ARE THE ONLY MEANS TO BE USED TO LIFT THE ELEMENTS. THE PRECAST CONCRETE ELEMENTS MUST NOT BE SUPPORTED OR RAISED BY OTHER MEANS THAN THOSE GIVEN IN THE MANUALS AND DRAWINGS WTHOUT WRITTEN APPROVAL FROM CONTECHO ENGINEERED SOLUTIONS. 13.1.2. CONSTRUCTION EQUIPMENT WEIGHTRESTRICTIONS-IN NO CASE SHALL EQUIPMENT OPERATING IN EXCESS OF THE DESIGN LOAD (HL-93) BE PERMITTED OVER THE BRIDGE UNITS UNLESS APPROVED BY CONIMCHO ENGINEERED SOLUTIONS. 13.12.1. IN THE IMMEDIATE AREA OF THE BRIDGE UNITS, THE FOLLOWING RESTRICTIONS FOR THE USE OF HEAVY CONSTRUCTION MACHINERY DURING BACKFILLING OPERATIONS APPLY: • NO CONSTRUCTION EQUIPMENT SHALL CROSS THE BARE PRECAST CONCRETE BRIDGE UNIT • AFTER THE COMPACTED FILL LEVEL HAS REACHED A MINIMUM OF C OVER THE CROWN OF THE BRIDGE, CONSTRUCTION EQUIPMENT WITH A WEIGHT OF LESS THAN 10 TONS MAY CROSS THE BRIDGE. • AFTER THE COMPACTED FILL LEVEL HAS REACHED A MINIMUM OF T-0- OVER THE CROWN OF THE BRIDGE, CONSTRUCTION EQUIPMENT WITH A WEIGHT OF LESS THAN 30 TONS MAY CROSS THE BRIDGE. • AFTER THE COMPACTED FILL LEVEL HAS REACHED THE DESIGN COVER, OR 2'-0" MINIMUM, OVER THE CROWN OF THE PRECAST CONCRETE BRIDGE, CONSTRUCTION EQUIPMENT WITHIN THE DESIGN LOAD LIMITS FOR THE ROAD MAY CROSS THE PRECAST CONCRETE BRIDGE. 132. LEVELING PAD/SHIMS- THE BRIDGE UNITS AND WINGWALLS SHALL BE SET ON HARDBOARD SHIMS CONFORMING TO ASTM D1037 OR PLASTIC SHIMS (DAYTON SUPERIOR PSO, PS1 OR APPROVED EQUAL) MEASURING 5" x 5', MINIMUM, UNLESS SHOWN OTHERWISE ON THE PLANS. A MINIMUM GAP OF & SHALL BE PROVIDED BETWEEN THE FOOTING AND THE BOTTOM OF THE BRIDGE'S VERTICAL LEGS OR THE BOTTOM OF THE WINGWALL. ALSO, A SUPPLY OF y', & AND K" THICK HARDBOARD OR PLASTIC SHIMS FOR VARIOUS SHIMMING PURPOSES SHALL BE ON SITE. 13S. PLACEMENT OF BRIDGE UNITS- THE BRIDGE UNITS SHALL BE PLACED AS SHOWN ON THE ENGINEERS PLAN DRAWINGS. SPECIAL CARE SHALL BE TAKEN IN SETTING THE ELEMENTS TO THE TRUE LINE AND GRADE. THE JOINT WIDTH BETWEEN ADJACENT PRECAST UNITS SHALL NOT EXCEED 31". 13A. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN THE STRUCTURE SPAN DURING ALL PHASES OF INSTALLATION. DUE TO THE ARCH SHAPE, BRIDGE ELEMENTS WILL TEND TO SPREAD UNDER SELF -WEIGHT. IT IS IMPERATIVE THAT ANY LATERAL SPREADING OF THE BRIDGE ELEMENTS BE AVOIDED DURING AND AFTER THEIR PLACEMENT. GENERALLY, HORIZONTAL CABLE TIES OR TIE RODS ARE SHIPPED IN THE LARGER BRIDGE ELEMENTS TO ASSIST IN PREVENTING THIS SPREADING. CABLE TIES IE RODS SHALL NOT BE REMOVED UNTILL BRIDGE UNITS ARE GROUTED AND GROUT HAS CURED. IT IS RECOMMENDED THAT TEMPORARY HARDWOOD BLOCKS BE USED IN CONJUNCTION WITH THE CABLE TIESrTIE RODS TO MAINTAIN SPAN. IF, HOWEVER, DUE TO SITE RESTRICTIONS, THESE CABLE TIESTTIE RODS MUST BE REMOVED PRIOR TO PLACEMENT OF THE BRIDGE ELEMANTS, THE CONTRACTOR MUST NOTIFY CONTECH (MANUFACTURER) AND REQUEST SUGGESTED INSTALLATION PROCEDURE. IN ADDITION, IF THE CABLE TIESrFE RODS MUST BE REMOVED PRIOR TO SETTING ARCH UNITS, THE FOLLOWING QUALITY CONTROL PROCEDURE MUST BE FOLLOWED: 1) FIND 'MEASURED SPAN" UPON ARCH UNITS DELIVERY TO SITE, PRIOR TO LIFTING FROM TRUCK AND REMOVING CABLE TIESrFE RODS. "MEASURED SPAN' SHALL BE THE AVERAGE OF (3) SPAN MEASUREMENTS ALONG THE LAY LENGTH OF THE ARCH UNIT. 2) AFTER SETTING OF BRIDGE UNIT ON THE FOUNDATION, VERIFY THE SPAN. THIS 'INSTALLED SPAN MEASUREMENT" SHALL NOT EXCEED THE MAXIMUM OF: A) THE NOMINAL SPAN ♦& OR B)THE -MEASURED SPAN" IF THE 'INSTALLED SPAN MEASUREMENT' EXCEEDS THIS AMOUNT, THE ARCH UNIT SHALL BE LIFTED AND RE -SET UNTIL THE "INSTALLED SPAN MEASUREMENT" MEETS THE LIMITS. 13.5. PLACEMENT OF WWGWALLS,HEADWALLSAND FOUNDATION UNITS - THE WINGWALLS, HEADWALLS AND FOUNDATIONS SHALL BE PLACED AS SHOWN ON THE PLAN DRAWINGS. SPECIAL CARE SHALL BE TAKEN IN SETTING THE ELEMENTS TO THE TRUE LINE AND GRADE. 13.6. JOINT PROTECTION AND SUBSURFACE DRAINAGE 13A.L EXTERNAL PROTECTION OF JOINTS- THE BUTT JOINT MADE BY JOINT WRAP TO BE USED SHALL BE APPLIED FOR A MINIMUM WIDTH OF W ON EACH SIDE OF THE JOINT. THE EXTERNAL WRAP SHALL BE CS212 BY CONCRETE SEALANTS INC.. EZ-WRAP RUBBER BY PRESS -SEAL GASKET CORPORATION, SEAL WRAP BY MAR MAC MANUFACTURING CO. INC. OR APPROVED EQUAL. THE JOINT SHALL BE COVERED CONTINUOUSLY FROM THE BOTTOM OF ONE BRIDGE SECTION LEG, ACROSS THE TOP OF THE BRIDGE AND TO THE OPPOSITE BRIDGE SECTION LEG. ANY LAPS THAT RESULT IN THE JOINT WRAP SHALL BE A MINIMUM OF 6" LONG WITH THE OVERLAP RUNNING DOWNHILL. 13e.Z IN ADDITION TO THE JOINTS BETWEEN BRIDGE UNITS THEJOINT BETWEEN THE END BRIDGE UNIT AND THE HEADWALL SHALL ALSO BE SEALED AS DESCRIBED ABOVE. IF PRECAST WINGWALLS ARE USED, THE JOINT BETWEEN THE END BRIDGE UNIT AND THE WINGWALL SHALL BE SEALED WITH A Z-0" STRIP OF FILTER FABRIC. ALSO, IF LIFT HOLES ARE FORMED IN THE BRIDGE UNITS, THEY SHALL BE PRIMED AND COVERED WITH A 9" x W SQUARE OF JOINT WRAP. 13.6.3. DURING THE BACKFLLING OPERATION, CARE SHALL BE TAKEN TO KEEP THE JOINT WRAP IN ITS PROPER LOCATION OVER THE JOINT. 13A.4. SUBSOIL DRAINAGE SHALL BE AS DIRECTED BY THE ENGINEER. 13.7. GROUTING 13.7.1. GROUTING SHALL NOT BE PERFORMED WHEN TEMPERATURES ARE EXPECTED TO GO BELOW 35" FOR A PERIOD OF 72 HOURS. GROUTING SHOULD BE COMPLETED AS SOON AS PRACTICAL AFTER PRECAST ARCHES HAVE BEEN INSTALLED. FILL THE BRIDGETOUNDATION KEYWAY WITH CEMENT GROUT (PORTLAND CEMENT AND WATER OR CEMENT MORTAR COMPOSED OF PORTLAND CEMENT, ND AND WATER WITH A MINIMUM V COMPRESSIVE C ,SA I B4N CO 55 STRENGTH A 3000 OUNPSI.VIBRATEASREQUIRED TO ENSURE THAT THE ENTIRE KEY ELEMENTS THE BRIDGE ELEMENT IS COMPLETELY FILLED. IF BRIDGEELEMENTS HAVE BEEN SET TEMPORARY TIES (CABLES. BARS, ETC.) GROUT MUST ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 1500 PSI BEFORE TIES MAY BE REMOVED. 13.7.3. Li LING TSH ECTIMEAMAXI RECEG RELATE BEFIL D 13.].3. LIFTING AND ERECTION ANCHOR RECESSES SHALL BE FILIED WITH GROUT. 133.AFTER GROUT HAS REACHED ITS DESIGN STRENGTH THE TEMPORARY HARDWOOD WEDGES SHALL BE REMOVED AND THEIR HOLES FILLED WITH GROUT. 13.8. BACKFILL 13.8.1. DO NOT PERFORM BACKFILLING DURING WET OR FREEZING WEATHER. 13.8.E NENTSUNIILTHEYHA BEEN AGAINSED BY STRUCTURAL ELEMENTSUNTILTHBHAVEIDERED AS ALL BY THE ENGINEER. 13.8.A BACKFIUL EMBANALLBECONSIDERED AS ALL REPLACEDNCRETE ON ANDNEW EMBANKOJECT CONSTRUCTION TO THE PRECAST CONCRETE ELEMENTS. THE PROJECT CONSTRUCTION AND MATERIAL SPECIFICATIONS, TINCLUDE THE SPECIFICATIONS FOR S EXCAVATION FOR STRUCTURES AND ROADWAY EXCAVATION AND EMBANKMENT CONSTRUCTION, SHALLAPPLV EXCEPT AS MODIFIED IN THIS SECTION. 13.BACKFILL ZONES: • IN • IN -SITU SOIL • ZONE A: CONSTRUCTED EMBANKMENT OR OVERFILL. • ZONE B: FILL THAT IS DIRECTLY ASSOCIATED WITH PRECAST CONCRETE BRIDGE INSTALLATION. • ZONE C: ROAD STRUCTURE. 1ES 13..5. REQUIRED IL-NATUACKFILL RAL GROUND 13.8.5.1. INSITU SOIL- NATURAL GROUND IS TO BE SUFFICIENTLY STABLE TO ALLOW EFFECTIVE SUPPORTTO THE PRECAST CONCRETE OUSTING BRIDGE UNITS. GUIDE, THE EXISTING NATURAL GROUND SIMILAR SHOULD BEOF SIMILARQUALITY LATERAL DI DENSITY TO ZONE I MATERIAL FOR MINIMUM LATERAL DIMENSION OF ONE BRIDGE SPAN OUTSIDE OF THE BRIDGE FOOTING. 13.8.5.2. ZONE AA REQUIRES FILL MATERIAL WITH SPECIFICATIONS AND COMPACTING PROCEDURES EQUAL TO THAT FOR NORMAL ROAD EMBANKMENTS. o,'." re' 'n_'m jMARKI DATE I REVISION DESCRIPTION 13.8.5S. ZONE B -GENERALLY, SOILS SHALL BE REASONABLY FREE OF ORGANIC MATTER, AND, NEAR CONCRETE SURFACES, FREE OF STONES LARGER THAN T IN DIAMETER SEE CHARTS FOR 13S.5A. ZONE C -ZONE C IS THE ROAD SECTION OF GRAVEL, ASPHALT OR CONCRETE BUILT IN COMPLIANCE WITH LOCAL ENGINEERING PRACTICES. 13.8.5.5. GEOTECHNICAL ENGINEER SHALL REVIEW GRADATIONS OF ALL INTERFACING MATERIALS AND, IF NECESSARY, RECOMMEND GEOTEXTILE FILTER FABRIC (PROVIDED BY CONTRACTOR) 13.8AL PLACING AND COMPACTING BACKFILL DUMPING FOR BACKFILLING IS NOT ALLOWED ANY NEARER THAN 3'-0" FROM THE BRIDGE LEG. THE FILL MUST BE PLACED AND COMPACTED IN LAVERS NOT EXCEEDING 8'. THE MAXIMUM DIFFERENCE IN THE SURFACE LEVELS OF THE FILL ON OPPOSITE SIDES OF THE BRIDGE MUST NOT EXCEED 2'-0". THE FILL BEHIND WINGWALLS MUST BE PLACED AT THE SAME TIME AS THAT OF THE BRIDGE FILL. IT MUST BE PLACED IN PROGRESSIVELY PLACED HORIZONTAL LAYERS NOT EXCEEDING W PER LAYER. THE BACKFILL OF ZONE B SHALL BE COMPACTED TO A MINIMUM DENSITY OF 95%OF THE STANDARD PROCTOR, AS REQUIRED BY AASHTO T-99. SOIL WITHIN 1'-0" OF CONCRETE SURFACES SHALL BE HAND -COMPACTED. ELSEWHERE, USE OF ROLLERS IS ACCEPTABLE. IF VIBRATING ROLLER -COMPACTORS ARE USED, THEY SHALL NOT BE STARTED OR STOPPED WITHIN ZONE B AND THE VIBRATION FREQUENCY SHOULD BE AT LEAST 30 REVOLUTIONS PER SECOND. THE BACKFILL MATERIAL AND COMPACTING BEHIND WINGWALLS SHALL SATISFY THE CRITERIA FOR THE BRIDGE BACKFILL. ZONE B. BACKRUL AGAINST A WATERPROOFED SURFACE SHALL BE PLACED CAREFULLY TO AVOID DAMAGE TO THE WATERPROOFING MATERIAL. 13AT BRIDGE UNITS FOR FILL HEIGHTS OVER 12 FEET (AS MEASURED FROM TOP CROWN OF BRIDGE TO FINISHED GRADE), NO BACKFILLING MAY BEGIN UNTIL A BACKFILL COMPACTION TESTING PLAN HAS BEEN COORDINATED WITH AND APPROVED BY CONTECM ENGINEERED SOLUTIONS. 13JBIL WINGWALLS BACKFILL IN FRONT OF WINGWALLS SHALL BE CARRIED TO GROUND LINES SHOWN IN THE PLANS. 13.8.9. MONITORING THE CONTRACTOR SHALL CHECK SETTLEMENTS AND HORIZONTAL DISPLACEMENT OF FOUNDATION TO ENSURE THAT THEY ARE WITHIN THE ALLOWABLE LIMIT PROVIDED BY THE ENGINEER. THESE MEASUREMENTS SHOULD GIVE AN INDICATION OF THE SETTLEMENTS AND DEFORMATIONS ALONG THE LENGTH OF THE FOUNDATIONS. THE FIRST MEASUREMENT SHOULD TAKE PLACE AFTER THE ERECTION OF ALL PRECAST BRIDGE SYSTEM ELEMENTS, A SECOND AFTER COMPLETION OF BACKFILLING, AND A THIRD BEFORE OPENING OF THE BRIDGE TO TRAFFIC. FURTHER MEASUREMENTS MAY BE MADE ACCORDING TO LOCAL CONDITIONS. NTECH• ENIMNEEMD SIDUMOM uC www.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 8DO-338-1122 513645-7000 513 6457993 FAX VARIES BY ANCHOR TYPE A= 3'-2" B=4'-1• C= 5'-1' FINISHED GRADE D=6'-1" 1'-0" COMPACTED MATERIAL E-T-1' MIN. (SAME AS UNIT BACKFILL) F=8'-1" PRECAST Oo �°jB 2' abodo -\ WINGWALL �°m$�° o2° o W�4 epodo ° moo. Q ppa° Ww° O9b o IN -SITU SOIL _ GROUT 15M�SPAL O-SERIES.. CONTRACT DRAWING ACCEPTABLE SOILS FOR USE IN ZONE B BACKFILL PERCENTPASSING CHPRPCTER C£ OVCTON TYPICAL AABHTO AASHTO USSIEVENo. PASSING NQ 4TSIEY£ USCS MATERIALS GROUP SUBGROUP SOIL DESRIPTION *10 >!40 412DO TOLD nAS LIMITIMIT ING. GIN, GP, SP A-ta 50 MAX 30 MAX 15 MAX 6 MAX LARGELY GRAVEL BUT CAN At INCLUDE SAND AND FINES GM, SW, A -lb 50 MAX 25 MAX 6 MAX GRAVELLY SAND OR GRADED SP, SM SAND, MAY INCLUDE FINES GM, SM, ML, A 2J 35 MAX 40 MAX 10 MAX SANDS, GRAVELS WITH LOW- SP, 6, PLASTICITY SILT FINES BE, GC, GM A-2-5 35 MAX 41 MIN LOMAX SANDS, GRAVELS WITH PLASTIC SILT FINES SP, SM, BIN iFINESANDS A3 51 MIN LOMAX Ow pIASTIC ML. SM, SC A4 36 MIN 1 40 MAX LOMAX I LOW-COMPRESSIBILTY SILTS +Pd A B / oi�pj IN -SITU SOIL 7 G' 1/ FINISHED GRADE TO ROADWAY BASE FINISH GRADEORTMIN. LIMITS OF CRITICAL BACKFILL ZONE B 08 A 4 B e� o4l, .4 IN SITU L SOIL 7 SPAN FILL HEIGHT ACCEPTABLEMATERIAL INSIDE ZONE B s 24'-0" z 12'-0" Al, A3 s 24'-0' <12' Y A1, A2, A3, A4 > 24'-0' ALL Al. A3 BACKFILL REQUIREMENTS VARIES SEE LIMITS OF FABRICATION EXCAVATION / DRAWINGS ZONE A TIE RODS LIMITS OF CRITICAL BACKFILL ZONE (C.B.Z.) PLEASANT GREEN SUBDIVISION ALBEMARLE COUNTY, VIRGINIA PRQIECTNo.: 689029 SEM N°.: DATE: 010 3/1 O 2022 DESIGNED:JMF DRA JCH CHECKED: SPS APPROVED: PAC SHEET NO.: CT9 DE CT9