Loading...
HomeMy WebLinkAboutARB202100131 Plan - Approved 2022-05-09SITE DATA INITIAL SITE PLAN NUMBER SPD202100054 FINAL SITE PLAN NUMBER SDP202700084 ADDRESS 1636 SEMINOLE TRAIL CHARLOTTESVILLE, VA OWNER MIMOSA LLC PO BOX 7652 CHARLOTTESVILLE, VA 22906 DEVELOPER HALLE PROPERTIES, LLC C/O DISCOUNT TIRE 20225 N. SCOTTSDALE ROAD SCOTTSDALE, AZ 85255 TMP 06100-00-00-120JO JURISDICTION ALBEMARLE COUNTY MAGISTERIAL DISTRICT RIO DISTRICT ZONING PROPOSED USE TIRE SALES EXISTING HIGHWAY COMMERCIAL - HC PROPOSED HIGHWAY COMMERCIAL- HC ZONING OVERLAY DISTRICT AIRPORT IMPACT AREA AND ENTRANCE CORRIDOR STEEP SLOPES - MANAGED SITE AREA 1.32 AC BUILDING AREA 7,680 SF BUILDING AREA PERCENTAGE OF SITE AREA 12.96% MAXIMUM BUILDING HEIGHT 65 FEET PROP. BUILDING HEIGHT 26 FEET (1-STORY) PROP. IMPERVIOUS COVER OF SITE AREA 1.06 AC (80%) PROP. OPEN SPACE 0.26 AC (20%) PARKING REQUIRED 1 SPACE PER EMPLOYEE PLUS 2 SPACES PER SERVICE BAY = (1 *15) + (6*2) = 15 + 12 = 27 SPACES MAXIMUM PARKING ALLOWED: NO MORE THAN 20%THE REQUIRED = (27*120%) = 32 SPACES PARKING PROVIDED 32 SPACES HANDICAP 2 SPACES (1 VAN SPACE) REFERENCES AND CONTACTS REFERENCES ♦BOUNDARY & TOPOGRAPHIC SURVEY: BOHLER 12825 WORLDGATE DRIVE, SUITE 700 HERNDON, VA 20170 DATED: 04/20/2021 SURVEY JOB SV211201 ELEVATIONS: BASED ON GPS OBSERVATIONS *ARCHITECTURAL PLAN: ARCHITECTURAL RESOURCE TEAM 1055 E. INDIAN SCHOOL ROAD PHOENIX, AZ 85014 CAD FILE NAMED: "VAC 12457 - CHARLOTTESVILLE, VA - CONCEPTUAL FLOOR PLAN - 6B-RH-60.DWG" DATED: 10/182021 ♦GEOTECHNICAL REPORT: ECS MID -ATLANTIC, LLC 4004 HUNTERSTAND COURT, SUITE 102 CHARLOTTESVILLE, VA 22911 DATED: 05252021 GOVERNING AGENCIES *ALBEMARLE COUNTY SITE REVIEW COMMITTEE ALBEMARLE COUNTY, VA 401 MCINTIRE ROAD CHARLOTTESVILLE, VA 22902 PHONE: (434) 243-7929 UTILITIES ♦ALBEMARLE COUNTY SERVICE AUTHORITY 168 SPOTNAP ROAD CHARLOTTESVILLE, VA 22911 PHONF: (434) 9774511 * THE ABOVE REFERENCED DOCUMENTS ARE INCORPORATED BY REFERENCE AS PART OF THESE PLANS, HOWEVER, BOHLER ENGINEERING DOES NOT CERTIFY THE ACCURACY OF THE WORK REFERENCED OR DERIVED FROM THESE DOCUMENTS, BY OTHERS. FINAL SITE PLAN DOCUMENTS APPROVAL DATE DEPARTMENT OF COMMUNITY DEVELOPMENT PLANNER/ZONING ENGINEER INSPECTIONS ARB DEPARTMENT OF FIRE RESCUE ALBEMARLE COUNTY SERVICE AUTHORITY VIRGINIA DEPARTMENT OF TRANSPORTATION HEALTH DEPARTMENT GENERAL NOTE: IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THIS PROJECT WORK SCOPE PRIOR TO THE INITIATION OF CONSTRUCTION. SHOULD THE CONTRACTOR FIND CONFLICT WITH THE DOCUMENTS RELATIVE P THE SPECIFICATIONS OR APPLICABLE CODES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PROJECT ENGINEER OF RECORD IN WRITING PRIOR TO THE START OF CONSTRUCTION. FAILURE BY THE CONTRACTOR TO NOTIFY THE PROJECT ENGINEER SHAU_ CONSTITUTE ACCEPTANCE OF FULL RESPONSIBILITY BY THE CONTRACTOR TO COMPLETE THE SCOPE OF THE WORK AS DEFINED BY THE DRAWINGS AND If FALL CONFORMANCE WITH LOCAL REGULATIONS AND CODES. FOR 131m%ZEEEflu LOCATION OF SITE 1636 SEMINOLE TRAIL ALBEMARLE COUNTY CHARLOTTESVILLE, VIRGINIA RIO MAGISTERIAL DISTRICT D.B. 1980 PG. 239 TMP: 06100-00-00-120JO ;y �/� Carrsheook \ xn / nemmury . School a F � PS / Yj°�Wvodbrvvk n spy � Nememary nool 5 m gw.m oe Mr a tl14,_ qo 4 ya 7 N" SITE ■ 4 F iowrnvoul T E 4 a c6 s' , °Ayt l; +o %q Beemlay /� Cnaeeelesvlll. ��'bAo kg *f`eW Rd r,ml°n squa.z A'� r• Noe s a * 'ew Re c c '+ Squire Hill a n WakefielE t 4'a Ala _ ^h.� a ch".I Hill, B OWNER ADDRESS:C/O DUFFY BIRCKHEAD P.O. BOX 7652 CHARLOTTESVILLE VA, 22906 OWNER CONTACT: FRANK BIRKHEAD LOCATION MAP SCALE: 1" = 2,000 Copyright: Microsoft Corporation DEVELOPER HALLE PROPERTIES, LLC C/O DISCOUNT TIRE 20225 N. SCOTTSDALE ROAD SCOTTSDALE, AZ 85255 CONTACT: BILL SHRUM DEVELOPER PHONE: (480)-606-6838 PREPARED BY HLER// CONTACT: RYAN T YAUGER, P.E. SHEETINDEX SHEET TITLE SHEET NUMBER COVER SHEET C-101 GENERALNOTES C-102 GENERAL NOTES AND LEGEND C-103 ALTA/NSPS LAND TITLE SURVEY (BY OTHERS) C-201 - 202 EXISTING CONDITIONS AND DEMOLITION PLAN C-203 SITE PLAN C-301 SITE CROSS SECTION C-302 FIRELANE PLAN C-303 TRUCK MOVEMENT PLAN C-304 GRADING PLAN C401 UTILITY PLAN C-501 UTILITY PROFILES C-502 - 503 UTILITY COMPUTATIONS C-504 LANDSCAPE PLAN C-701 LANDSCAPE COMPLIANCE C-702 LANDSCAPE NOTES AND DETAILS C-703 IRRIGATION PLAN C-704 IRRIGATION NOTES AND DETAILS C-705 - 710 SITE PHOTOMETRIC PLAN (BY OTHERS) C-711 CONCEPTUAL ELEVATIONS (BY OTHERS) SIGHT DISTANCE PROFILE LC-712 01 CONSTRUCTION DETAILS SHEET - 902 SHEET TOTAL = 30 %L f � 71. 4 h rista ph er Ta gg a rt, Dig itall Sigr iatute ' ARB Approved Plan May 9: 2022 �f IRiafe� z EE w W W (n Z F W z W��w� W 2 2 Wow � W ZrCOH�rn Z Fw0 wz �>UWrnO U)72QQQ Z(n2 W ZK, — 0zaQa~Of 0<OW Wm z J 00 z) W Z z D- Q U W H V) REVISIONS REV I DATE I COMMENT 1 10/29/2021 PER ISP COMMENTS RTY 2 01/21/2022 PER COUNTY COMMENTS BSC RTY 3 04/08/2022 PER COUNTY COMMENTS BSC RTY 15 Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DISH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: CNDS-2 PROJECT: SITE PLAN DOCUMENTS FOR DIStagmu PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLER// 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@BohlerEng.com TH Lic. No. 0402056625 SHEET TITLE: 04/08/2022 COVER SHEET SHEET NUMBER: C-101 REVISION 3 - 04/08/2022 GENERAL NOTES (Rev. 22021) DEMOLITION NOTES (Rev. 22021) SITE LAYOUT NOTES (Rev. 12020) LIGHTING NOTES (Rev. 12020) W O Z . U n O 3 A i 0 N Z U 0 N 3 W F N J Z y w 0 3 Il N 0 Z 3 m 9 a U 1. THESE PLANS ARE SOLELY BASED ON INFORMATION THE OWNER AND OTHERS PROVIDED TO BOHLER ENGINEERING, VIRGINIA (HEREIN "BOHLER' PRIOR TO THE DATE ON WHICH THE ENGINEER OF RECORD AND BOHLER PREPARED THESE PLANS. THE CONTRACTOR MUST FIELD VERIFY ALL EXISTING CONDITIONS AND IMMEDIATELY NOTIFY BOHLER , IN WRITING, IF ANY ACTUAL SITE CONDITIONS DIFFER FROM THOSE SHOWN ON THESE PLANS, OR IF THE PROPOSED WORK CONFLICTS WITH ANY OTHER SITE FEATURES. 2. THE CONTRACTOR MUST STRICTLY COMPLY WITH THESE NOTES AND ALL SPECIFICATIONSIREPORTS CONTAINED HEREIN. THE CONTRACTOR MUST EN RE THATALL B NTRA T R F LLY AND MPLETELY NF RM T AND MPLY WITH THE E RE IREMENT THE E N TE AND THE SU SU CO COS U CO CO O O CO S QU S S O S REQUIREMENTS ARTICULATED IN THE NOTES CONTAINED IN ALL THE OTHER DRAWINGS THAT COMPRISE THE PLAN SET OF DRAWINGS. ADDITIONAL N TE AND PE IFI PLAN N TE MAY BE F ND N THE INDIVID AL PLAN . THE E ENERAL N TE APPLY T THI ENTIRE D MENT PA KA E. O S S C C O S OU O U S S G O S O S OCU C G IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL CONSTRUCTION CONTRACT DOCUMENTS INCLUDING, BUT NOT LIMITED TO, ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THE PROJECT WORK SCOPE, PRIOR TO THE INITIATION AND COMMENCEMENT OF CONSTRUCTION. 3. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR MUST CONFIRM WITH THE ENGINEER OF RECORD AND BOHLER THAT THE LATEST EDITION OF THE DOCUMENTS AND/OR REPORTS REFERENCED WITHIN THE PLAN REFERENCES ARE BEING USED FOR CONSTRUCTION. THIS IS THE CONTRACTOR'S SOLE AND COMPLETE RESPONSIBILITY. 4. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR MUST ENSURE THAT ALL REQUIRED PERMITS AND APPROVALS HAVE BEEN OBTAINED. NO CONSTRUCTION OR FABRICATION IS TO BEGIN UNTIL THE CONTRACTOR HAS RECEIVED AND THOROUGHLY REVIEWED THE CONDITIONS OF APPROVAL TO ALL PLANS AND OTHER DOCUMENTS REVIEWED AND APPROVED BY THE PERMITTING AUTHORITIES AND HAS ALSO CONFIRMED THAT ALL NECESSARY AND REQUIRED PERMITS HAVE BEEN OBTAINED. THE CONTRACTOR MUST HAVE COPIES OF ALL PERMITS AND APPROVALS ON SITE AT ALL TIMES. 5. THE CONTRACTOR MUST ENSURE THATALL WORK IS PERFORMED IN ACCORDANCE WITH THESE PLANS, SPECIFICATIONSIREPORTS AND CONDITIONS OF APPROVAL AND ALL APPLICABLE REQUIREMENTS RULES REGULATIONS STATUTORY REQUIREMENTS CODES LAWS AND STANDARDS OF ALL GOVERNMENTAL ENTITIES WITH JURISDICTION OVER THIS PROJECT AND ALL PROVISIONS IN AND CONDITIONS OF THE CONSTRUCTION CONTRACT WITH THE OWNER/DEVELOPER INCLUDING ALL EXHIBITS ATTACHMENTS AND ADDENDA TO SAME. 6. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION THE CONTRACTOR MUST COORDINATE THE BUILDING LAYOUT BY CAREFULLY REVIEWING THE MOST CURRENT ARCHITECTURAL CIVIL AND STRUCTURAL CONSTRUCTION DOCUMENTS INCLUDING BUT NOT LIMITED TO MECHANICAL ELECTRICAL, PLUMBING AND FIRE SUPPRESSION PLANS, WHERE APPLICABLE). THE CONTRACTOR MUST IMMEDIATELY NOTIFY OWNER, ARCHITECT AND ENGINEER OF RECORD AND BOHLER, IN WRITING, OF ANY CONFLICTS, DISCREPANCIES OR AMBIGUITIES WHICH EXIST BETWEEN THESE PLANS AND ANY OTHER PLANS THAT COMPRISE THE CONSTRUCTION DOCUMENTS. 7. CONTRACTOR MUST REFER TO AND ENSURE COMPLIANCE WITH THE APPROVED ARCHITECTURALBUILDING PLANS OF RECORD FOR EXACT LOCATIONS AND DIMENSIONS OF ENTRYIEXIT POINTS, ELEVATIONS, PRECISE BUILDING DIMENSIONS, AND EXACT BUILDING UTILITY LOCATIONS. 8. THE CONTRACTOR MUST FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS SHOWN ON THESE PLANS, PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. THE CONTRACTOR MUST IMMEDIATELY NOTIFY ENGINEER OF RECORD AND BOHLER, IN WRITING, IF ANY CONFLICTS, DISCREPANCIES, OR AMBIGUITIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION. NO EXTRA COMPENSATION WILL BE PAID TO THE CONTRACTOR FOR WORK WHICH HAS TO BE RE -DONE OR REPAIRED DUE TO DIMENSIONS MEASUREMENTS OR GRADES SHOWN INCORRECTLY ON THESE PLANS PRIOR TO BOTH A THE CONTRACTOR GIVING ENGINEER OF RECORD AND BOHLER WRITTEN NOTIFICATION OF SAME AND B () () ENGINEER OF RECORD AND BOHLER, THEREAFTER, PROVIDING THE CONTRACTOR WITH WRITTEN AUTHORIZATION TO PROCEED WITH SUCH ADDITIONAL WORK. 9. THE CONTRACTOR MUST VERIFY ALL DIMENSIONS AND MEASUREMENTS INCLUDED ON DESIGN DOCUMENTS HEREIN AND MUST NOT SCALE OFF THE DRAWINGS DUE TO POTENTIAL PRINTING INACCURACIES. ALL DIMENSIONS AND MEASUREMENTS ARE TO BE CHECKED AND CONFIRMED BY THE GENERAL CONTRACTOR PRIOR TO PREPARATION OF SHOP DRAWINGS, FABRICATION/ORDERING OF PARTS AND MATERIALS AND COMMENCEMENT OF SITE WORK. SITE PLAN DRAWINGS ARE NOT INTENDED AS SURVEY DOCUMENTS. DIMENSIONS SUPERSEDE GRAPHICAL REPRESENTATIONS. THE CONTRACTOR MUST MAKE CONTRACTOR'S OWN MEASUREMENTS FOR LAYOUT OF IMPROVEMENTS. 10. THE OWNER AND CONTRACTOR MUST BE FAMILIAR WITH AND RESPONSIBLE FOR THE PROCUREMENT OF ANY AND ALL CERTIFICATIONS REQUIRED FOR THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 11. WHEN INCLUDED AS ONE OF THE REFERENCED DOCUMENTS, THE GEOTECHNICAL REPORT, SPECIFICATIONS AND RECOMMENDATIONS SET FORTH THEREIN ARE A PART OF THE REQUIRED CONSTRUCTION DOCUMENTS AND, IN CASE OF CONFLICT, DISCREPANCY OR AMBIGUITY, THE MORE STRINGENT REQUIREMENTS AND/OR RECOMMENDATIONS CONTAINED IN: (A) THE PLANS; AND (B) THE GEOTECHNICAL REPORT AND RECOMMENDATIONS, MUST TAKE PRECEDENCE UNLESS SPECIFICALLY NOTED OTHERWISE ON THE PLANS. THE CONTRACTOR MUST NOTIFY THE ENGINEER OF RECORD AND BOHLER, IN WRITING, OF ANY SUCH CONFLICT, DISCREPANCY OR AMBIGUITY BETWEEN THE GEOTECHNICAL REPORT AND PLANS AND SPECIFICATIONS, PRIOR TO PROCEEDING WITH ANY FURTHER WORK. IF A GEOTECHNICAL REPORT WAS NOT CREATED, THEN THE CONTRACTOR MUST FOLLOW AND COMPLY WITH ALL OF THE REQUIREMENTS OF ANY AND ALL MUNICIPAL, COUNTY, STATE, AND FEDERAL LAWS AND APPLICABLE SPECIFICATIONS WHICH HAVE JURISDICTION OVER THIS PROJECT. 12. ENGINEER OF RECORD AND BOHLER ARE NEITHER LIABLE NOR RESPONSIBLE FOR ANY SUBSURFACE CONDITIONS AND FURTHER, HAS NO LIABILITY FOR ANY HAZARDOUS MATERIALS, HAZARDOUS SUBSTANCES, OR POLLUTANTS ON, ABOUT OR UNDER THE PROPERTY. 13. THE CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING WHEN AND WHERE SHORING IS REQUIRED AND FOR INSTALLING ALL SHORING REQUIRED DURING EXCAVATION (TO BE PERFORMED IN ACCORDANCE WITH CURRENT OSHA STANDARDS) AND ANY ADDITIONAL PRECAUTIONS TO BE TAKEN TO ASSURE THE STABILITY OF ADJACENT, NEARBY AND CONTIGUOUS STRUCTURES AND PROPERTIES. ALL OF THIS WORK IS TO BE PERFORMED AT CONTRACTOR'S SOLE COST AND EXPENSE. 14. THE CONTRACTOR MUST EXERCISE EXTREME CAUTION WHEN PERFORMING ANY WORK ACTIVITIES ADJACENT TO PAVEMENT, STRUCTURES, ETC. WHICH ARE TO REMAIN EITHER FOR AN INITIAL PHASE OF THE PROJECT OR AS PART OF THE FINAL CONDITION. THE CONTRACTOR IS RESPONSIBLE FOR TAKING ALL APPROPRIATE MEASURES REQUIRED TO ENSURE THE STRUCTURAL STABILITY OF SIDEWALKS AND PAVEMENT, UTILITIES, BUILDINGS, AND INFRASTRUCTURE WHICH ARE TO REMAIN, AND TO PROVIDE A SAFE WORK AREA FOR THIRD PARTIES, PEDESTRIANS AND ANYONE INVOLVED WITH THE PROJECT. 15. DEBRIS MUST NOT BE BURIED ON THE SUBJECT SITE. ALL DEMOLITION AND CONSTRUCTION WASTES, UNSUITABLE EXCAVATED MATERIAL, EXCESS SOIL AND DEBRIS (SOLID WASTE) MUST BE DISPOSED OF IN ACCORDANCE WITH THE REQUIREMENTS OF ANY AND ALL MUNICIPAL, COUNTY, STATE, AND FEDERAL LAWS AND APPLICABLE CODES WHICH HAVE JURISDICTION OVER THIS PROJECT OR OVER THE CONTRACTOR. 16. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO MAINTAIN RECORDS TO DEMONSTRATE PROPER AND FULLY COMPLIANT DISPOSAL ACTIVITIES, TO BE PROMPTLY PROVIDED TO THE OWNER UPON REQUEST. 17. THE CONTRACTOR MUST REPAIR, AT CONTRACTOR'S SOLE COST, ALL DAMAGE DONE TO ANY NEW OR EXISTING CONSTRUCTION OR PROPERTY DURING THE COURSE OF CONSTRUCTION, INCLUDING BUT NOT LIMITED TO DRAINAGE, UTILITIES, PAVEMENT, STRIPING, CURB, ETC. AND MUST BEAR ALL COSTS ASSOCIATED WITH SAME TO INCLUDE, BUT NOT BE LIMITED TO, REDESIGN, RE -SURVEY, RE -PERMITTING AND CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR AND MUST REPLACE ALL SIGNAL INTERCONNECTION CABLE, WIRING CONDUITS, AND ANY UNDERGROUND ACCESSORY EQUIPMENT DAMAGED DURING CONSTRUCTION AND MUST BEAR ALL COSTS ASSOCIATED WITH SAME. THE REPAIR OF ANY SUCH NEW OR EXISTING CONSTRUCTION OR PROPERTY MUST RESTORE SUCH CONSTRUCTION OR PROPERTY TO A CONDITION EQUIVALENT TO OR BETTER THAN THE CONDITIONS PRIOR TO COMMENCEMENT OF THE CONSTRUCTION, AND IN CONFORMANCE WITH APPLICABLE CODES, LAWS, RULES, REGULATIONS, STATUTORY REQUIREMENTS AND STATUTES. THE CONTRACTOR MUST BEAR ALL COSTS ASSOCIATED WITH SAME. THE CONTRACTOR MUST, PROMPTLY, DOCUMENT ALL EXISTING DAMAGE AND NOTIFY, IN WRITING, THE OWNER AND THE CONSTRUCTION MANAGER PRIOR TO THE START OF CONSTRUCTION. 18. THE ENGINEER OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR AND HAVE NO CONTRACTUAL, LEGAL OR OTHER RESPONSIBILITIES FOR JOB SITE SAFETY JOB SITE SUPERVISION, OR ANYTHING RELATED TO SAME. THE ENGINEER OF RECORD AND BOHLER HAVE NOT BEEN RETAINED TO PERFORM OR TO BE RESPONSIBLE FOR JOB SITE SAFETY, SAME BEING WHOLLY OUTSIDE OF ENGINEER OF RECORD'S AND BOHLER SERVICES AS RELATED TO THE PROJECT. THE ENGINEER OF RECORD AND BOHLER ARE NOT RESPONSIBLE TO IDENTIFY OR REPORT ANY JOB SITE SAFETY ISSUES OR ANY JOB SITE CONDITIONS, AT ANY TIME. 19. THE CONTRACTOR MUST IMMEDIATELY IDENTIFY IN WRITING, TO THE ENGINEER OF RECORD AND BOHLER , ANY DISCREPANCIES THAT MAY OR COULD AFFECT THE PUBLIC SAFETY, HEALTH OR GENERAL WELFARE, OR PROJECT COST. IF THE CONTRACTOR PROCEEDS WITH CONSTRUCTION WITHOUT PROVIDING PROPER WRITTEN NOTIFICATION AS DESCRIBED ABOVE, IT WILL BE AT THE CONTRACTOR'S OWN RISK AND, FURTHER, THE CONTRACTOR MUST INDEMNIFY, DEFEND AND HOLD HARMLESS THE ENGINEER OF RECORD AND BOHLER FOR ANY AND ALL DAMAGES, COSTS, INJURIES, ATTORNEY'S FEES AND THE LIKE WHICH RESULT FROM OR ARE IN ANY WAY RELATED TO SAME INCLUDING, BUT NOT LIMITED TO, ANY THIRD PARTY AND FIRST PARTY CLAIMS. 20. THE ENGINEER OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR ANY INJURY OR DAMAGES RESULTING FROM THE CONTRACTOR'S FAILURE TO BUILD OR CONSTRUCT IN STRICT ACCORDANCE WITH THE APPROVED PLANS, AND CURRENT CODES, RULES, STATUTES AND THE LIKE. IF THE CONTRACTOR AND/OR OWNER FAIL TO BUILD OR CONSTRUCT IN STRICT ACCORDANCE WITH APPROVED PLANS, RULES, STATUTES, CODES AND THE LIKE, THE CONTRACTOR AND/OR OWNER AGREE TO AND MUST JOINTLY, INDEPENDENTLY, SEPARATELY, AND SEVERALLY INDEMNIFY AND HOLD THE ENGINEER OF RECORD AND BOHLER HARMLESS FOR AND FROM ALL INJURIES, CLAIMS AND DAMAGES THAT ENGINEER AND BOHLER SUFFER AND ANY AND ALL COSTS THAT ENGINEER AND BOHLER INCUR AS RELATED TO SAME. 21. ALL CONTRACTORS MUST CARRY AT LEAST THE MINIMUM AMOUNT OF THE SPECIFIED AND COMMERCIALLY REASONABLE STATUTORY WORKER'S COMPENSATION INSURANCE, EMPLOYER'S LIABILITY INSURANCE AND COMMERCIAL GENERAL LIABILITY INSURANCE (CGL) INCLUDING ALSO ALL UMBRELLA COVERAGES. ALL CONTRACTORS MUST HAVE THEIR CGL POLICIES ENDORSED TO NAME BOHLER , AND ITS PAST, PRESENT AND FUTURE OWNERS, OFFICERS, DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS, COMMISSIONERS, AGENTS, SERVANTS, EMPLOYEES, AFFILIATES, SUBSIDIARIES, AND RELATED ENTITIES, AND ITS SUBCONTRACTORS AND SUBCONSULTANTS AS ADDITIONAL NAMED INSUREDS AND TO PROVIDE CONTRACTUAL LIABILITY COVERAGE SUFFICIENT TO INSURE (DEFEND, IF APPLICABLE) AND HOLD HARMLESS AND INDEMNITY OBLIGATIONS ASSUMED AND AGREED TO BY THE CONTRACTOR HEREIN. ALL CONTRACTORS MUST FURNISH BOHLER WITH CERTIFICATIONS OF INSURANCE OR CERTIFICATES OF INSURANCE AS EVIDENCE OF THE REQUIRED INSURANCE COVERAGES PRIOR TO COMMENCING ANY WORK AND UPON RENEWAL OF EACH POLICY DURING THE ENTIRE PERIOD OF CONSTRUCTION AND FOR TWO YEARS AFTER THE COMPLETION OF CONSTRUCTION AND AFTER ALL PERMITS ARE ISSUED, WHICHEVER DATE IS LATER. IN ADDITION, ALL CONTRACTORS AGREE THAT THEY WILL, TO THE FULLEST EXTENT PERMITTED UNDER THE LAW, INDEMNIFY, DEFEND AND HOLD HARMLESS BOHLER AND ITS PAST, PRESENT AND FUTURE OWNERS, OFFICERS, DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS, COMMISSIONERS, AGENTS, SERVANTS, EMPLOYEES, AFFILIATES, SUBSIDIARIES, AND RELATED ENTITIES, AND ITS SUBCONTRACTORS AND SUBCONSULTANTS FROM AND AGAINST ANY DAMAGES, INJURIES, CLAIMS, ACTIONS, PENALTIES, EXPENSES, PUNITIVE DAMAGES, TORT DAMAGES, STATUTORY CLAIMS, STATUTORY CAUSES OF ACTION, LOSSES, CAUSES OF ACTION, LIABILITIES OR COSTS, INCLUDING, BUT NOT LIMITED TO, REASONABLE ATTORNEYS' FEES AND DEFENSE COSTS, ARISING OUT OF OR IN ANY WAY CONNECTED WITH OR TO THE PROJECT, INCLUDING ALL CLAIMS BY EMPLOYEES OF THE CONTRACTOR(S), ALL CLAIMS BY THIRD PARTIES AND ALL CLAIMS RELATED TO THE PROJECT. THE CONTRACTOR MUST NOTIFY ENGINEER, IN WRITING, AT LEAST THIRTY (30) DAYS PRIOR TO ANY TERMINATION, SUSPENSION OR CHANGE OF ITS INSURANCE HEREUNDER. 22. THE ENGINEER OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR CONSTRUCTION METHODS, MEANS, TECHNIQUES OR PROCEDURES, GENERALLY OR FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES OR PROCEDURES FOR COMPLETION OF THE WORK DEPICTED BOTH ON THESE PLANS, AND FOR ANY CONFLICTS IN SCOPE AND REVISIONS THAT RESULT FROM SAME. THE CONTRACTOR IS FULLY AND SOLELY RESPONSIBLE FOR DETERMINING THE MEANS AND METHODS FOR COMPLETION OF THE WORK, PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 23. NEITHER THE PROFESSIONAL ACTIVITIES OF BOHLER, NOR THE PRESENCE OF BOHLER AND/OR ITS PAST, PRESENT AND FUTURE OWNERS, OFFICERS, DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS, COMMISSIONERS, AGENTS, SERVANTS, EMPLOYEES, AFFILIATES, SUBSIDIARIES, AND RELATED ENTITIES, AND ITS SUBCONTRACTORS AND SUBCONSULTANTS AT A CONSTRUCTION/PROJECT SITE (HEREIN `BOHLER PARTIES', RELIEVES OR WILL RELIEVE THE CONTRACTOR OF AND FROM CONSTRUCTION MEANS, METHODS, SEQUENCE, TECHNIQUES OR PROCEDURES NECESSARY FOR PERFORMING, OVERSEEING, SUPERINTENDING AND COORDINATING THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND COMPLIANCE WITH ALL HEALTH AND SAFETY PRECAUTIONS REQUIRED BY ANY REGULATORY AGENCIES WITH JURISDICTION OVER THE PROJECT AND/OR PROPERTY. BOHLER PARTIES HAVE NO AUTHORITY TO EXERCISE ANY CONTROL OVER (OR ANY RESPONSIBILITY FOR) ANY CONSTRUCTION, THE CONTRACTOR OR ITS EMPLOYEES RELATING TO THEIR WORK AND ANY AND ALL HEALTH AND SAFETY PROGRAMS OR PROCEDURES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR JOB SITE SAFETY. THE CONTRACTOR MUST INDEMNIFY, DEFEND, PROTECT AND HOLD HARMLESS BOHLER PARTIES FOR AND FROM ANY LIABILITY TO BOHLER PARTIES RESULTING FROM THE CONTRACTOR'S WORK, SERVICES AND/OR VIOLATIONS OF THIS NOTE, THESE NOTES OR ANY NOTES IN THE PLAN SET AND, FURTHER, THE CONTRACTOR MUST NAME BOHLER AS AN ADDITIONAL INSURED UNDER THE GENERAL CONTRACTOR'S POLICIES OF GENERAL LIABILITY INSURANCE AS DESCRIBED ABOVE. 24. WHEN IT IS CLEARLY AND SPECIFICALLY WITHIN BOHLER'S SCOPE OF SERVICES CONTRACT WITH THE OWNER/DEVELOPER, BOHLER WILL REVIEW OR TAKE OTHER APPROPRIATE ACTION ON THE CONTRACTOR SUBMITTALS, SUCH AS SHOP DRAWINGS, PRODUCT DATA, SAMPLES, AND OTHER DATA, WHICH THE CONTRACTOR IS REQUIRED TO SUBMIT, BUT ONLY FOR THE LIMITED PURPOSE OF EVALUATING CONFORMANCE WITH THE DESIGN INTENT AND THE INFORMATION SHOWN IN THE CONSTRUCTION CONTRACT DOCUMENTS. CONSTRUCTION MEANS AND METHODS AND/OR TECHNIQUES OR PROCEDURES, COORDINATION OF THE WORK WITH OTHER TRADES, AND CONSTRUCTION SAFETY PRECAUTIONS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND BOHLER HAS NO RESPONSIBILITY OR LIABILITY FOR SAME. BOHLER WILL PERFORM ITS SHOP DRAWING REVIEW WITH REASONABLE PROMPTNESS, AS CONDITIONS PERMIT. ANY DOCUMENT, DOCUMENTING BOHLER'S REVIEW OF A SPECIFIC ITEM OR LIMITED SCOPE, MUST NOT INDICATE THAT BOHLER HAS REVIEWED THE ENTIRE ASSEMBLY OF WHICH THE ITEM IS A COMPONENT. BOHLER IS NOT RESPONSIBLE FOR ANY DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR MUST, IN WRITING, PROMPTLY AND IMMEDIATELY BRING ANY DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS TO BOHLER'S ATTENTION. BOHLER IS NOT REQUIRED TO REVIEW PARTIAL SUBMISSIONS OR THOSE FOR WHICH SUBMISSIONS OF CORRELATED ITEMS HAVE NOT BEEN RECEIVED. 25. IF THE CONTRACTOR DEVIATES FROM THESE PLANS AND/OR SPECIFICATIONS, INCLUDING THE NOTES CONTAINED HEREIN, WITHOUT FIRST OBTAINING THE PRIOR WRITTEN AUTHORIZATION OF THE ENGINEER OF RECORD AND BOHLER FOR ALL DEVIATIONS WITHIN ENGINEER'S SCOPE, THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE PAYMENT OF ALL COSTS INCURRED IN CORRECTING ANY WORK PERFORMED WHICH DEVIATES FROM THE PLANS, ALL FINES AND/OR PENALTIES ASSESSED WITH RESPECT THERETO AND ALL COMPENSATORY OR PUNITIVE DAMAGES RESULTING THEREFROM AND, FURTHER, MUST DEFEND, INDEMNIFY, PROTECT, AND HOLD HARMLESS THE ENGINEER OF RECORD AND BOHLER PARTIES TO THE FULLEST EXTENT PERMITTED UNDER THE LAW, FOR AND FROM ALL FEES, ATTORNEYS' FEES, DAMAGES, COSTS, JUDGMENTS, CLAIMS, INJURIES, PENALTIES AND THE LIKE RELATED TO SAME. 26. THE CONTRACTOR IS RESPONSIBLE FOR A MAINTAINING AND PROTECTING THE TRAFFIC CONTROL PLAN AND ELEMENTS IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REQUIREMENTS, FOR ALL WORK THAT AFFECTS PUBLIC TRAVEL EITHER IN THE RIGHT OF WAY OR ON SITE. THE COST FOR THIS ITEM MUST BE INCLUDED IN THE CONTRACTOR'S PRICE AND IS THE CONTRACTOR'S SOLE RESPONSIBILITY. 27. OWNER MUST MAINTAIN AND PRESERVE ALL PHYSICAL SITE FEATURES AND DESIGN FEATURES DEPICTED ON THE PLANS AND RELATED DOCUMENTS IN STRICT ACCORDANCE WITH THE APPROVED PLAN(S) AND DESIGN; AND, FURTHER, THE ENGINEER OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR ANY FAILURE TO SO MAINTAIN OR PRESERVE SITE AND/OR DESIGN FEATURES. IF OWNER FAILS TO MAINTAIN AND/OR PRESERVE ALL PHYSICAL SITE FEATURES AND/OR DESIGN FEATURES DEPICTED ON THE PLANS AND RELATED DOCUMENTS, OWNER AGREES TO INDEMNIFY AND HOLD THE ENGINEER OF RECORD AND BOHLER PARTIES, HARMLESS FOR ALL INJURIES, DAMAGES AND COSTS THAT ENGINEER OF RECORD AND BOHLER INCUR AS A RESULT OF SAID FAILURE OR FAILURE TO PRESERVE. 28. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ENSURING THAT ALL CONSTRUCTION ACTIVITIES AND MATERIALS COMPLY WITH AND CONFORM TO APPLICABLE FEDERAL, STATE AND LOCAL RULES AND REGULATIONS, LAWS, ORDINANCES, AND CODES, AND ALL APPLICABLE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.) AS AMENDED, AND ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME. 29. THE CONTRACTOR MUST STRICTLY COMPLY WITH THE LATEST AND CURRENT OSHA STANDARDS AND REGULATIONS, AND/OR ANY OTHER AGENCY WITH JURISDICTION OVER EXCAVATION AND TRENCHING PROCEDURES. ENGINEER OF RECORD AND BOHLER HAS NO RESPONSIBILITY FOR OR AS RELATED TO EXCAVATION AND TRENCHING PROCEDURES AND WORK. 30. THE CONTRACTOR AND THE OWNER MUST INSTALL ALL ELEMENTS AND COMPONENTS IN STRICT COMPLIANCE WITH AND IN ACCORDANCE WITH MANUFACTURER'S STANDARDS AND RECOMMENDED INSTALLATION CRITERIA AND SPECIFICATIONS. IF THE CONTRACTOR AND/OR OWNER FAIL TO DO SO, THEY AGREE TO JOINTLY, INDEPENDENTLY, SEPARATELY, COLLECTIVELY, AND SEVERALLY INDEMNIFY, DEFEND, PROTECT AND HOLD ENGINEER OF RECORD AND BOHLER PARTIES HARMLESS FOR ALL INJURIES AND DAMAGES THAT ENGINEER SUFFERS AND COSTS THAT ENGINEER INCURS AS A RESULT OF SAID FAILURE. 31. THE CONTRACTOR IS RESPONSIBLE TO MAINTAIN AN ON -SITE STORMWATER POLLUTION PREVENTION PLAN (SWPPP) IN COMPLIANCE WITH THE ENVIRONMENTAL PROTECTION AGENCY (EPA) REQUIREMENTS OR LOCAL GOVERNING AGENCY FOR SITES WHERE ONE (1) ACRE OR MORE IS DISTURBED BY CONSTRUCTION ACTIVITIES (UNLESS THE LOCAL JURISDICTION REQUIRES A DIFFERENT THRESHOLD). THE CONTRACTOR MUST ENSURE THAT ALL ACTIVITIES, INCLUDING THOSE OF ALL SUBCONTRACTORS, ARE IN COMPLIANCE WITH THE SWPPP, INCLUDING BUT NOT LIMITED TO LOGGING ACTIVITIES (MINIMUM ONCE PER WEEK AND AFTER RAINFALL EVENTS) AND CORRECTIVE MEASURES, AS APPROPRIATE AND FURTHER, THE CONTRACTOR IS SOLELY AND COMPLETELY RESPONSIBLE FOR FAILING TO DO SO. 32. AS CONTAINED IN THESE DRAWINGS AND ASSOCIATED DOCUMENTS PREPARED BY THE ENGINEER OF RECORD AND BOHLER, THE USE OF THE WORDS'CERTIFY' OR'CERTIFICATION' CONSTITUTE(S) AN EXPRESSION ONLY OF PROFESSIONAL OPINION REGARDING THE INFORMATION WHICH IS THE SUBJECT OF THE ENGINEER OF RECORD'S AND BOHLER KNOWLEDGE OR BELIEF AND IN ACCORDANCE WITH COMMON AND ACCEPTED PROCEDURE CONSISTENT WITH THE APPLICABLE STANDARDS OF PRACTICE, AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE OF ANY NATURE OR TYPE, EITHER EXPRESSED OR IMPLIED, UNDER ANY CIRCUMSTANCES. 1. THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES. 2. THE CONTRACTOR MUST CONDUCT DEMOLITIONIREMOVALS ACTIVITIES IN SUCH A MANNER AS TO ENSURE MINIMUM INTERFERENCE WITH ROADS STREETS SIDEWALKS WALKWAYS AND ALL OTHER ADJACENT FACILITIES. THE CONTRACTOR MUST OBTAIN ALL APPLICABLE PERMITS FROM THE APPROPRIATE GOVERNMENTAL AUTHORITY IES PRIOR TO THE ( ) COMMENCEMENT OF ANY ROAD OPENING OR DEMOLITION ACTIVITIES IN OR ADJACENT TO THE RIGHT-OF-WAY. 3. WHEN DEMOLITION -RELATED ACTIVITIES IMPACT ROADWAYS AND/OR ROADWAY RIGHT-OF-WAY THE CONTRACTOR MUST PROVIDE TRAFFIC CONTROL AND GENERALLY ACCEPTED SAFE PRACTICES IN CONFORMANCE WITH THE CURRENT FEDERAL HIGHWAY ADMINISTRATION "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" MUTCD AND THE FEDERAL STATE AND LOCAL REGULATIONS. 4. THE DEMOLITION AND/OR REMOVALS PLAN IS INTENDED TO PROVIDE GENERAL INFORMATION AND TO IDENTIFY ONLY ( ) CONDITIONS REGARDING ITEMS TO BE DEMOLISHED REMOVED AND/OR TO REMAIN. A. THE CONTRACTOR MUST ALSO REVIEW ALL CONSTRUCTION DOCUMENTS AND INCLUDE WITHIN THE DEMOLITION ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE CONSTRUCTION OF THE NEW SITE IMPROVEMENTS. B. THIS PLAN IS NOT INTENDED TO AND DOES NOT PROVIDE DIRECTION REGARDING THE MEANS METHODS SEQUENCING TECHNIQUES AND PROCEDURES TO BE EMPLOYED TO ACCOMPLISH THE WORK. ALL MEANS METHODS SEQUENCING TECHNIQUES AND PROCEDURES TO BE USED MUST BE IN STRICT ACCORDANCE AND CONFORMANCE WITH ALL STATE, FEDERAL, LOCAL, AND JURISDICTIONAL REQUIREMENTS. THE CONTRACTOR MUST COMPLY WITH ALL OSHA AND OTHER SAFETY PRECAUTIONS NECESSARY TO PROVIDE A SAFE WORK SITE FOR THE CONTRACTOR AND THE PUBLIC. 5. THE CONTRACTOR MUST PROVIDE ALL "METHODS AND MEANS" NECESSARY TO PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OF EXISTING STRUCTURES, AND ANY OTHER IMPROVEMENTS THAT ARE REMAINING ON OR OFF SITE. THE CONTRACTOR, AT THE CONTRACTOR'S SOLE COST, MUST REPAIR ALL DAMAGE TO ALL ITEMS AND FEATURES THAT ARE TO REMAIN. CONTRACTOR MUST USE NEW MATERIAL FOR ALL REPAIRS. CONTRACTOR'S REPAIRS MUST INCLUDE THE RESTORATION OF ALL ITEMS AND FEATURES REPAIRED TO THEIR PRE -DEMOLITION CONDITION, OR BETTER. CONTRACTOR MUST PERFORM ALL REPAIRS AT THE CONTRACTOR'S SOLE EXPENSE. 6. ENGINEER OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR JOB SITE SAFETY OR SUPERVISION. THE CONTRACTOR MUST PROCEED WITH THE DEMOLITION IN A SYSTEMATIC AND SAFE MANNER COMPLYING WITH ALL OSHA REQUIREMENTS TO ENSURE PUBLIC AND CONTRACTOR SAFETY AND SAFETY TO ALL PROPERTY ON THE SITE OR ADJACENT OR NEAR TO THE SAME. 7. THE CONTRACTOR IS RESPONSIBLE FOR JOB SITE SAFETY, WHICH MUST INCLUDE, BUT IS NOT LIMITED TO, THE INSTALLATION AND MAINTENANCE OF BARRIERS, FENCING, OTHER APPROPRIATE AND/OR NECESSARY SAFETY FEATURES AND ITEMS NECESSARY TO PROTECT THE PUBLIC FROM AREAS OF CONSTRUCTION AND CONSTRUCTION ACTIVITIES. THE CONTRACTOR MUST SAFEGUARD THE SITE AS NECESSARY TO PERFORM THE DEMOLITION IN SUCH A MANNER AS TO PREVENT THE ENTRY OF ALL UNAUTHORIZED PERSONS AT ANY TIME, TO OR NEAR THE DEMOLITION AREA. 8. PRIOR TO THE COMMENCEMENT OF ANY SITE ACTIVITY AND ANY DEMOLITION ACTIVITY, THE CONTRACTOR MUST, IN WRITING, RAISE ANY QUESTIONS CONCERNING THE ACCURACY OR INTENT OF THESE PLANS AND/OR SPECIFICATIONS, ALL CONCERNS OR QUESTIONS REGARDING THE APPLICABLE SAFETY STANDARDS, AND/OR THE SAFETY OF THE CONTRACTOR AND/OR THIRD PARTIES IN PERFORMING THE WORK ON THIS PROJECT. ANY SUCH CONCERNS MUST BE CONVEYED TO THE ENGINEER OF RECORD AND BOHLER , IN WRITING AND MUST ADDRESS ALL ISSUES AND ITEMS RESPONDED TO, BY THE ENGINEER OF RECORD AND BY BOHLER, IN WRITING. ALL DEMOLITION ACTIVITIES MUST BE PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS, RULES, REQUIREMENTS, STATUTES, ORDINANCES AND CODES. 9. THE CONTRACTOR MUST BECOME FAMILIAR WITH THE APPLICABLE UTILITY SERVICE PROVIDER REQUIREMENTS AND IS RESPONSIBLE FOR ALL COORDINATION REGARDING UTILITY DEMOLITION AND/OR DISCONNECTION AS IDENTIFIED OR REQUIRED FOR THE PROJECT. THE CONTRACTOR MUST PROVIDE THE OWNER WITH WRITTEN NOTIFICATION THAT THE EXISTING UTILITIES AND SERVICES HAVE BEEN TERMINATED, REMOVED AND/OR ABANDONED IN ACCORDANCE WITH THE JURISDICTION AND UTILITY COMPANY REQUIREMENTS AND ALL OTHER APPLICABLE REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES. 10. PRIOR TO COMMENCING ANY DEMOLITION, THE CONTRACTOR MUST: A. OBTAIN ALL REQUIRED PERMITS AND MAINTAIN THE SAME ON SITE FOR REVIEW BY THE ENGINEER AND ALL PUBLIC AGENCIES WITH JURISDICTION THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK, AND DEMOLITION WORK. B. NOTIFY, AT A MINIMUM, THE MUNICIPAL ENGINEER, DESIGN ENGINEER, AND LOCAL SOIL CONSERVATION JURISDICTION, AT LEAST 72 BUSINESS HOURS PRIOR TO THE COMMENCEMENT OF WORK. C. INSTALL THE REQUIRED SOIL EROSION AND SEDIMENT CONTROL MEASURES PRIOR TO SITE DISTURBANCE, AND MAINTAIN SAID CONTROLS UNTIL SITE IS STABILIZED D. IN ACCORDANCE WITH STATE LAW, THE CONTRACTOR MUST CALL THE STATE ONE -CALL DAMAGE PROTECTION SYSTEM FOR UTILITY MARK OUT, IN ADVANCE OF ANY EXCAVATION. E. LOCATE AND PROTECTALL UTILITIES AND SERVICES, INCLUDING BUT NOT LIMITED TO GAS, WATER, ELECTRIC, SANITARY AND STORM SEWER, TELEPHONE, CABLE, FIBER OPTIC CABLE, ETC. WITHIN AND ADJACENT TO THE LIMITS OF PROJECT ACTIVITIES. THE CONTRACTOR MUST USE AND COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE UTILITY NOTIFICATION SYSTEM TO LOCATE ALL UNDERGROUND UTILITIES. F. PROTECT AND MAINTAIN IN OPERATION, ALL ACTIVE UTILITIES AND SYSTEMS THAT ARE NOT BEING REMOVED DURING ANY DEMOLITION ACTIVITIES. G. ARRANGE FOR AND COORDINATE WITH THE APPLICABLE UTILITY SERVICE PROVIDER(S) FOR THE TEMPORARY OR PERMANENT TERMINATION OF SERVICE REQUIRED BY THE PROJECT PLANS AND SPECIFICATIONS REGARDING THE METHODS AND MEANS TO CONSTRUCT SAME. THESE ARE NOT THE ENGINEER OF RECORD'S RESPONSIBILITY. IN THE EVENT OF ABANDONMENT, THE CONTRACTOR MUST PROVIDE THE UTILITY ENGINEER AND OWNER WITH IMMEDIATE WRITTEN NOTIFICATION THAT THE EXISTING UTILITIES AND SERVICES HAVE BEEN TERMINATED AND ABANDONED IN ACCORDANCE WITH JURISDICTIONAL AND UTILITY COMPANY REQUIREMENTS. H. ARRANGE FOR AND COORDINATE WITH THE APPLICABLE UTILITY SERVICE PROVIDER(S) REGARDING WORKING "OFF-PEAK' HOURS OR ON WEEKENDS AS NECESSARY OR AS REQUIRED TO MINIMIZE THE IMPACT ON, OF, AND TO THE AFFECTED PARTIES. WORK REQUIRED TO BE PERFORMED "OFF-PEAK' IS TO BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER. I. IN THE EVENT THE CONTRACTOR DISCOVERS ANY HAZARDOUS MATERIAL, THE REMOVAL OF WHICH IS NOT ADDRESSED IN THE PROJECT PLANS AND SPECIFICATIONS OR THE CONTRACT WITH THE OWNER/DEVELOPER, THE CONTRACTOR MUST IMMEDIATELY CEASE ALL WORK IN THE AREA OF DISCOVERY, AND IMMEDIATELY NOTIFY, IN WRITING AND VERBALLY, THE OWNER AND ENGINEER OF RECORD AND BOHLER, THE DISCOVERY OF SUCH MATERIALS TO PURSUE PROPER AND COMPLIANT REMOVAL OF SAME. 11. THE CONTRACTOR MUST NOT PERFORM ANY EARTH MOVEMENT ACTIVITIES, DEMOLITION OR REMOVAL OF FOUNDATION WALLS, FOOTINGS, OR OTHER MATERIALS WITHIN THE LIMITS OF DISTURBANCE, UNLESS SAME IS IN STRICT ACCORDANCE AND CONFORMANCE WITH THE PROJECT PLANS AND SPECIFICATIONS, OR PURSUANT TO THE WRITTEN DIRECTION OF THE OWNER'S STRUCTURAL OR GEOTECHNICAL ENGINEER. 12. DEMOLITION ACTIVITIES AND EQUIPMENT MUST NOT USE OR INCLUDE AREAS OUTSIDE THE DEFINED PROJECT LIMIT LINE, WITHOUT SPECIFIC WRITTEN PERMISSION AND AUTHORITY OF AND FROM THE OWNER AND ALL GOVERNMENTAL AGENCIES WITH JURISDICTION. 13. THE CONTRACTOR MUST BACKFILL ALL EXCAVATION RESULTING FROM, OR INCIDENTAL TO, DEMOLITION ACTIVITIES. BACKFILL MUST BE ACCOMPLISHED WITH APPROVED BACKFILL MATERIALS AND MUST BE SUFFICIENTLY COMPACTED TO SUPPORT ALL NEW IMPROVEMENTS AND MUST BE PERFORMED IN COMPLIANCE WITH THE RECOMMENDATIONS AND GUIDANCE ARTICULATED IN THE GEOTECHNICAL REPORT. BACKFILLING MUST OCCUR IMMEDIATELY AFTER DEMOLITION ACTIVITIES AND MUST BE PERFORMED SO AS TO PREVENT WATER ENTERING THE EXCAVATION. FINISHED SURFACES MUST BE GRADED TO PROMOTE POSITIVE DRAINAGE. THE CONTRACTOR IS RESPONSIBLE FOR COMPACTION TESTING AND MUST SUBMIT SUCH REPORTS AND RESULTS TO THE ENGINEER OF RECORD AND THE OWNER. 14. EXPLOSIVES MUST NOT BE USED WITHOUT PRIOR WRITTEN CONSENT FROM BOTH THE OWNER AND ALL APPLICABLE, NECESSARY AND REQUIRED GOVERNMENTAL AUTHORITIES. PRIOR TO COMMENCING ANY EXPLOSIVE PROGRAM AND/OR ANY DEMOLITION ACTIVITIES, THE CONTRACTOR MUST ENSURE AND OVERSEE THE INSTALLATION OF ALL OF THE REQUIRED PERMIT AND EXPLOSIVE CONTROL MEASURES THAT THE FEDERAL, STATE, AND LOCAL GOVERNMENTS REQUIRE. THE CONTRACTOR IS ALSO RESPONSIBLE TO CONDUCTAND PERFORM ALL INSPECTION AND SEISMIC VIBRATION TESTING THAT IS REQUIRED TO MONITOR THE EFFECTS ON ALL LOCAL STRUCTURES AND THE LIKE. 15. IN ACCORDANCE WITH FEDERAL, STATE, AND/OR LOCAL STANDARDS, THE CONTRACTOR MUST USE DUST CONTROL MEASURES TO LIMIT AIRBORNE DUSTAND DIRT RISING AND SCATTERING IN THE AIR. AFTER THE DEMOLITION IS COMPLETE, THE CONTRACTOR MUST CLEAN ALL ADJACENT STRUCTURES AND IMPROVEMENTS TO REMOVE ALL DUST AND DEBRIS WHICH THE DEMOLITION OPERATIONS CAUSE. THE CONTRACTOR IS RESPONSIBLE FOR RETURNING ALL ADJACENT AREAS TO THEIR "PRE -DEMOLITION" CONDITION AT CONTRACTOR'S SOLE COST. 16. PAVEMENT MUST BE SAW CUT IN STRAIGHT LINES. ALL DEBRIS FROM REMOVAL OPERATIONS MUST BE REMOVED FROM THE SITE AT THE TIME OF EXCAVATION. STOCKPILING OF DEBRIS OUTSIDE OF APPROVED AREAS WILL NOT BE PERMITTED, INCLUDING BUT NOT LIMITED TO, THE PUBLIC RIGHT-OF-WAY. 17. THE CONTRACTOR MUST MAINTAIN A RECORD SET OF PLANS WHICH INDICATES THE LOCATION OF EXISTING UTILITIES THAT ARE CAPPED, ABANDONED IN PLACE, OR RELOCATED DUE TO DEMOLITION ACTIVITIES. THIS RECORD DOCUMENT MUST BE PREPARED IN A NEAT AND WORKMAN -LIKE MANNER AND TURNED OVER TO THE OWNER/DEVELOPER UPON COMPLETION OF THE WORK, ALL OF WHICH IS AT THE CONTRACTOR'S SOLE COST. 18. THE CONTRACTOR MUST EMPTY, CLEAN AND REMOVE FROM THE SITE ALL UNDERGROUND STORAGE TANKS, IF ENCOUNTERED, IN ACCORDANCE WITH FEDERAL, STATE, COUNTY AND LOCAL REQUIREMENTS, PRIOR TO CONTINUING CONSTRUCTION IN THE AREA AROUND THE TANK WHICH EMPTYING, CLEANING AND REMOVAL ARE AT THE CONTRACTOR'S SOLE COST. SOIL EROSION & SEDIMENT CONTROL PLAN NOTES (Rev. 112020) 1. THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES. 2. EROSION CONTROL MEASURES MUST CONFORM TO THE VIRGINA GUIDELINES FOR URBAN EROSION AND SEDIMENT CONTROL UNLESS OTHERWISE NOTED, OR UNLESS ENGINEER CLEARLY AND SPECIFICALLY, IN WRITING, DIRECTS OTHERWISE. INSTALLATION OF EROSION CONTROL, CLEARING, AND SITE WORK MUST BE PERFORMED EXACTLY AS INDICATED IN THE EROSION CONTROL CONSTRUCTION NOTES. 3. THE DISTURBED LAND AREA OF THIS SITE IS APPROXIMATELY 1.31 ACRES. 4. THE FOLLOWING EROSION CONTROL MEASURES ARE PROPOSED FOR THIS SITE: A. STABILIZED CONSTRUCTION ENTRANCE/ EXIT -A TEMPORARY GRAVEL CONSTRUCTION ENTRANCE[EXIT IS TO BE INSTALLED AT THE DESIGNATED LOCATION SHOWN ON THE PLAN. THIS AREA MUST BE GRADED SO THAT RUNOFF WATER WILL BE RETAINED ON -SITE. B. SEDIMENT FENCE - INSTALL SILT FENCE(S) AND/OR SILT SOCK AROUND ALL OF THE DOWNSLOPE PERIMETERS OF THE SITE, TEMPORARY FILL AND SOIL STOCKPILES. C. INSTALL FILTER FABRIC DROP INLET PROTECTION AROUND EACH DRAINAGE INLET AS DRAINAGE STRUCTURES ARE INSTALLED TO REDUCE THE QUANTITY OF SEDIMENT. INSTALL TEMPORARY INLET PROTECTION ON INLETS DOWNSLOPE FROM DISTURBANCE, WHICH MAY BE BEYOND THE LIMITS OF DISTURBED AREA. 5. INSTALLATION OF EROSION CONTROL DEVICES MUST BE IN ACCORDANCE WITH ALL OF THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR MUST INSPECT EROSION CONTROL MEASURES WEEKLY. THE CONTRACTOR MUST REMOVE ANY SILT DEPOSITS GREATER THAN 6" COLLECTED ON THE FILTER FABRIC AND/OR SILT SOCK BARRIERS AND EXCAVATE AND REMOVE ANY SILT FROM DROP INLET PROTECTION. 7. THE CONTRACTOR MUST APPLY TEMPORARY SEED AND MULCH TO ALL DISTURBED AREAS THAT WILL NOT BE BROUGHT TO FINISHED GRADE AND VEGETATED WITHIN 7 DAYS. WHEN AREAS ARE DISTURBED AFTER THE GROWING SEASON, THE CONTRACTOR MUST STABILIZE SAME WITH GEOTEXTILE FABRIC AND MAINTAIN SAME IN STRICT ACCORDANCE WITH BEST MANAGEMENT PRACTICES. 8. THE CONTRACTOR MUST INSTALL ADDITIONAL EROSION CONTROL MEASURES IF ENGINEER SO REQUIRES, TO PREVENT ANY, INCLUDING THE INCIDENTAL, DISCHARGE OF SILT -LADEN RUNOFF FROM EXITING THE SITE. 9. THE CONTRACTOR MUST BE RESPONSIBLE FOR INSPECTING AND MAINTAINING ALL EROSION CONTROL MEASURES ON THE SITE UNTIL PERMANENT PAVING AND TURF/LANDSCAPING IS ESTABLISHED. THE COSTS OF INSTALLING AND MAINTAINING THE EROSION CONTROL MEASURES MUST BE INCLUDED IN THE BID PRICE FOR THE SITE WORK AND THE CONTRACTOR IS RESPONSIBLE FOR ALL SUCH COSTS. 10. THE CONTRACTOR MUST CONTINUE TO MAINTAIN ALL EROSION CONTROL MEASURES UNTIL THE COMPLETION OF CONSTRUCTION AND THE ESTABLISHMENT OF VEGETATION. 11. THE CONTRACTOR MUST REMOVE EROSION CONTROL MEASURES, SILT AND DEBRIS AFTER ESTABLISHING PERMANENT VEGETATION COVER OR OTHER INSTALLING A DIFFERENT, SPECIFIED METHOD OF STABILIZATION. 12. THIS PLAN REPRESENTS THE MINIMUM LEVEL OF IMPLEMENTATION OF TEMPORARY EROSION AND SEDIMENTATION CONTROL FACILITIES, MEASURES AND STRUCTURES. ADDITIONAL FACILITIES, MEASURES AND STRUCTURES MUST BE INSTALLED WHERE NECESSARY TO COMPLY WITH ALLAPPLICABLE CODES AND STANDARDS AND/OR TO PREVENT ANY, INCLUDING THE INCIDENTAL DISCHARGE OF SILT -LADEN RUNOFF FROM EXITING THE SITE. 13. THE CONTRACTOR MUST PROTECT ALL EXISTING TREES AND SHRUBS. THE CONTRACTOR MUST REFER TO THE LANDSCAPE AND/OR DEMOLITION PLAN(S) FOR TREE PROTECTION, FENCE LOCATIONS AND DETAILS. 14. THE CONTRACTOR MUST REFER TO GRADING PLANS FOR ADDITIONAL INFORMATION. 15. THE CONTRACTOR MUST CLEAN EXISTING AND PROPOSED DRAINAGE STRUCTURES AND INTERCONNECTING PIPES ON OR OFF -SITE AS THE JURISDICTIONAL AGENCY REQUIRES, BOTH AT THE TIME OF SITE STABILIZATION AND AT END OF PROJECT. 16. SOIL EROSION CONTROL MEASURES MUST BE ADJUSTED OR RELOCATED BY THE CONTRACTOR AS IDENTIFIED DURING SITE OBSERVATION IN ORDER TO MAINTAIN THE COMPLETE EFFECTIVENESS OF ALL CONTROL MEASURES. 17. THE CONTRACTOR MUST IDENTIFY, ON THE PLAN, THE LOCATION OF WASTE CONTAINERS, FUEL STORAGE TANKS, CONCRETE WASHOUT AREAS AND ANY OTHER LOCATIONS WHERE HAZARDOUS MATERIALS ARE STORED. 1. THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES. 2. PRIOR TO THE COMMENCEMENT OF GENERAL CONSTRUCTION, THE CONTRACTOR MUST INSTALL SOIL EROSION CONTROL AND ANY STORMWATER POLLUTION PREVENTION PLAN SWPPP MEASURES NECESSARY AS INDICATED ON THE APPROVED SOIL ( ) EROSION AND SEDIMENT CONTROL PLAN AND IN ACCORDANCE WITH APPLICABLE AND/OR APPROPRIATE AGENCIES' GUIDELINES TO PREVENT SEDIMENT AND/OR LOOSE DEBRIS FROM WASHING ONTO ADJACENT PROPERTIES OR THE RIGHT OF WAY. 3. ALL DIRECTIONAL/TRAFFIC SIGNING AND PAVEMENT STRIPING MUST CONFORM TO THE LATEST STANDARDS OF THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND ANY APPLICABLE STATE OR LOCALLY APPROVED SUPPLEMENTS, GUIDELINES RULES REGULATIONS STANDARDS AND THE LIKE. 4. THE LOCATIONS OF PROPOSED UTILITY POLES AND TRAFFIC SIGNS SHOWN ON THE PLANS ARE SCHEMATIC AND PRELIMINARY. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR FIELD -VERIFYING THEIR LOCATION. THE CONTRACTOR MUST COORDINATE THE RELOCATION OF TRAFFIC SIGNS WITH THE ENTITY WITH JURISDICTION OVER THE PROJECT. 5. ALL DIMENSIONS SHOWN ARE TO BOTTOM FACE OF CURB, EDGE OF PAVEMENT, OR EDGE OF BUILDING, EXCEPT WHEN DIMENSION IS TO A PROPERTY LINE, STAKE OUT OF LOCATIONS OF INLETS, LIGHT POLES, ETC. MUST BE PERFORMED IN STRICT ACCORDANCE WITH THE DETAILS UNLESS NOTED CLEARLY OTHERWISE. GRADING NOTES (Rev.22021) 1. THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES. 2. SITE GRADING MUST BE PERFORMED IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS AND THE RECOMMENDATIONS SET FORTH IN THE GEOTECHNICAL REPORT AS REFERENCED IN THIS PLAN SET. IF NO GEOTECHNICAL REPORT HAS BEEN REFERENCED THE CONTRACTOR MUST HAVE A GEOTECHNICAL ENGINEER PROVIDE WRITTEN SPECIFICATIONS AND RECOMMENDATIONS PRIOR TO THE CONTRACTOR COMMENCING THE GRADING WORK. THE CONTRACTOR MUST FOLLOW THE REQUIREMENTS OF ALL MUNICIPAL, COUNTY, STATE, AND FEDERAL LAWS, WHICH HAVE JURISDICTION OVER THIS PROJECT. 3. THE CONTRACTOR IS REQUIRED TO SECURE ALL NECESSARY AND/OR REQUIRED PERMITS AND APPROVALS FOR ALL OFF -SITE MATERIAL SOURCES AND DISPOSAL FACILITIES. THE CONTRACTOR MUST SUPPLY A COPY OF APPROVALS TO THE ENGINEER OF RECORD AND THE OWNER PRIOR TO THE CONTRACTOR COMMENCING ANY WORK. 4. THE CONTRACTOR IS FULLY RESPONSIBLE FOR VERIFYING EXISTING TOPOGRAPHIC INFORMATION AND UTILITY INVERT ELEVATIONS PRIOR TO COMMENCING ANY CONSTRUCTION. SHOULD DISCREPANCIES BETWEEN THE PLANS AND INFORMATION OBTAINED THROUGH FIELD VERIFICATIONS BE IDENTIFIED OR MST, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IN WRITING. 5. THE CONTRACTOR IS RESPONSIBLE FOR REMOVING AND REPLACING ALL UNSUITABLE MATERIALS WITH SUITABLE MATERIALS AS SPECIFIED IN THE GEOTECHNICAL REPORT. THE CONTRACTOR MUST COMPACT ALL EXCAVATED OR FILLED AREAS IN STRICT ACCORDANCE WITH THE GEOTECHNICAL REPORTS GUIDANCE. MOISTURE CONTENT AT TIME OF PLACEMENT MUST BE SUBMITTED IN A COMPACTION REPORT PREPARED BY A QUALIFIED GEOTECHNICAL ENGINEER, REGISTERED WITH THE STATE WHERE THE WORK IS PERFORMED. THIS REPORT MUST VERIFY THAT ALL FILLED AREAS AND SUBGRADE AREAS WITHIN THE BUILDING PAD AREA AND AREAS TO BE PAVED HAVE BEEN COMPACTED IN ACCORDANCE WITH THESE PLANS, SPECIFICATIONS AND THE RECOMMENDATIONS SET FORTH IN THE GEOTECHNICAL REPORT AND ALL APPLICABLE REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES WHICH ARE IN EFFECT AND WHICH ARE APPLICABLE TO THE PROJECT. SUBBASE MATERIAL FOR SIDEWALKS, CURB, OR ASPHALT MUST BE FREE OF ORGANICS AND OTHER UNSUITABLE MATERIALS. SHOULD SUBBASE BE DEEMED UNSUITABLE BY OWNERIDEVELOPER, OR OWNER/DEVELOPER'S REPRESENTATIVE, SUBBASE MUST BE REMOVED AND FILLED WITH APPROVED FILL MATERIAL, COMPACTED AS THE GEOTECHNICAL REPORT DIRECTS. EARTHWORK ACTIVITIES INCLUDING, BUT NOT LIMITED TO, EXCAVATION, BACKFILL, AND COMPACTING MUST COMPLY WITH THE RECOMMENDATIONS IN THE GEOTECHNICAL REPORT AND ALL APPLICABLE REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES. EARTHWORK ACTIVITIES MUST COMPLY WITH THE STANDARD STATE DOT SPECIFICATIONS FOR ROADWAY CONSTRUCTION (LATEST EDITION) AND ANY AMENDMENTS OR REVISIONS THERETO. 6. IN THE EVENT OF A DISCREPANCY(IES) AND/OR A CONFUCT(S) BETWEEN PLANS, OR RELATIVE TO OTHER PLANS, THE GRADING PLAN TAKES PRECEDENCE AND CONTROLS. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IN WRITING, OF ANY DISCREPANCY(IES) AND/OR CONFLICT(S). 7. THE CONTRACTOR IS RESPONSIBLE TO IMPORT FILL OR EXPORT EXCESS MATERIAL AS NECESSARY TO CONFORM TO THE PROPOSED GRADING, AND TO BACKFILL EXCAVATIONS FOR THE INSTALLATION OF UNDERGROUND IMPROVEMENTS. ACCESSIBILITY DESIGN GUIDELINES (Rev.12020) 1. ALL ACCESSIBLE (A.KA. ADA) COMPONENTS AND ACCESSIBLE ROUTES MUST BE CONSTRUCTED TO MEET, AT A MINIMUM, THE MORE STRINGENT OF: (A) THE REQUIREMENTS OF THE "AMERICANS WITH DISABILITIES ACT" (ADA) CODE (42 U.S.C. § 12101 ET SEC. AND 42 U.S.C. § 4151 ET SEQ.); AND (B) ANY APPLICABLE LOCAL AND STATE GUIDELINES, AND ANY AND ALL AMENDMENTS TO BOTH, WHICH ARE IN EFFECT WHEN THESE PLANS WERE COMPLETED. 2. THE CONTRACTOR MUST REVIEW ALL DOCUMENTS REFERENCED IN THESE NOTES FOR ACCURACY, COMPLIANCE AND CONSISTENCY WITH INDUSTRY GUIDELINES. 3. THE CONTRACTOR MUST EXERCISE APPROPRIATE CARE AND PRECISION IN CONSTRUCTION OF ACCESSIBLE (ADA) COMPONENTS AND ACCESSIBLE ROUTES FOR THE SITE. FINISHED SURFACES ALONG THE ACCESSIBLE ROUTE OF TRAVEL FROM PARKING SPACES, PUBLIC TRANSPORTATION, PEDESTRIAN ACCESS, AND INTER -BUILDING ACCESS, TO POINTS OF ACCESSIBLE BUILDING ENTRANCEEXIT, MUST COMPLY WITH THE ACCESSIBLE GUIDELINES AND REQUIREMENTS WHICH INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: A. ACCESSIBLE PARKING SPACES AND ACCESS AISLES SLOPES MUST NOT EXCEED 1:50 (2.0%) IN ANY DIRECTION. B. PATH OF TRAVEL ALONG ACCESSIBLE ROUTE MUST PROVIDE A 36-INCHES MINIMUM WIDTH (48-INCHES PREFERRED), OR AS SPECIFIED BY THE GOVERNING AGENCY. UNOBSTRUCTED WIDTH OF TRAVEL (CAR OVERHANGS AND/OR HANDRAILS) MUST NOT REDUCE THIS MINIMUM WIDTH. THE SLOPE MUST NOT EXCEED 1:20 (5.0%) IN THE DIRECTION OF TRAVEL AND MUST NOT EXCEED 1:50 (2.0%) IN CROSS SLOPE. WHERE ACCESSIBLE PATH OF TRAVEL IS GREATER THAN 1:20 (5.0%), AN ACCESSIBLE RAMP MUST BE PROVIDED. ALONG THE ACCESSIBLE PATH OF TRAVEL, OPENINGS MUST NOT EXCEED 12-INCH IN WIDTH. VERTICAL CHANGES OF UP TO 12-INCH ARE PERMITTED ONLY IF THEY INCLUDES A 1/41NCH BEVEL AT A SLOPE NOT STEEPER THAN 1:2. NO VERTICAL CHANGES OVER 1WINCH ARE PERMITTED. C. ACCESSIBLE RAMPS MUST NOT EXCEED A SLOPE OF 1:12 (8.3%) AND A RISE OF 30-INCHES. LEVEL LANDINGS MUST BE PROVIDED AT EACH END OF ACCESSIBLE RAMPS. LANDING MUST PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURES, AND MUST NOT EXCEED 1:50 (2.0%) SLOPE IN ANY DIRECTION. RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS MUST HAVE A CLEAR LANDING OF A MINIMUM OF 60-INCHES BY 60-INCHES. HAND RAILS ON BOTH SIDES OF THE RAMP MUST BE PROVIDED ON AN ACCESSIBLE RAMP WITH A RISE GREATER THAN 6-INCHES. D. ACCESSIBLE CURB RAMPS MUST NOT EXCEED A SLOPE OF 1:12 (8.3%). WHERE FLARED SIDES ARE PROVIDED, THEY MUST NOT EXCEED 1:10 (10%) SLOPE. LEVEL LANDING MUST BE PROVIDED AT RAMPS TOP AT A MINIMUM OF 36-INCHES LONG (48-INCHES PREFERRED). IN ALTERATIONS, WHEN THERE IS NO LANDING AT THE TOP, FLARE SIDES SLOPES MUST NOT EXCEED A SLOPE OF 1:12 (8.3%). E. DOORWAY LANDINGS AREAS MUST BE PROVIDED ON THE EXTERIOR SIDE OF ANY DOOR LEADING TO AN ACCESSIBLE PATH OF TRAVEL. THIS LANDING MUST BE SLOPED AWAY FROM THE DOOR NO MORE THAN 1:50 (2.0%) FOR POSITIVE DRAINAGE. THIS LANDING AREA MUST BE NO FEWER THAN 60-INCHES (5 FEET) LONG, EXCEPT WHERE OTHERWISE CLEARLY PERMITTED BY ACCESSIBLE STANDARDS FOR ALTERNATIVE DOORWAY OPENING CONDITIONS. (SEE ICC/ANSI A717.1-2009 AND OTHER REFERENCES INCORPORATED BY CODE). F. WHEN THE PROPOSED CONSTRUCTION INVOLVES RECONSTRUCTION, MODIFICATION, REVISION OR EXTENSION OF OR TO ACCESSIBLE COMPONENTS FROM EXISTING DOORWAYS OR SURFACES, THE CONTRACTOR MUST VERIFY ALL EXISTING ELEVATIONS SHOWN ON THE PLAN. NOTE THAT TABLE 405.2 OF THE DEPARTMENT OF JUSTICE'S ADA STANDARDS FOR ACCESSIBLE DESIGN ALLOWS FOR STEEPER RAMP SLOPES, IN RARE CIRCUMSTANCES. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IN WRITING, OF ANY DISCREPANCIES AND/OR FIELD CONDITIONS THAT DIFFER IN ANY WAY OR IN ANY RESPECT FROM WHAT IS SHOWN ON THE PLANS BEFORE COMMENCING ANY WORK. CONSTRUCTED IMPROVEMENTS MUST FALL WITHIN THE MAXIMUM AND MINIMUM LIMITATIONS IMPOSED BY THE BARRIER FREE REGULATIONS AND THE ACCESSIBLE GUIDELINES. G. THE CONTRACTOR MUST VERIFY ALL OF THE SLOPES OF THE CONTRACTOR'S FORMS PRIOR TO POURING CONCRETE. IF ANY NON-CONFORMANCE EXISTS OR IS OBSERVED OR DISCOVERED, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IN WRITING, PRIOR TO POURING CONCRETE. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL COSTS TO REMOVE, REPAIR AND/OR REPLACE NON -CONFORMING CONCRETE AND/OR PAVEMENT SURFACES. 4. IT IS STRONGLY RECOMMENDED THAT THE CONTRACTOR REVIEW THE INTENDED CONSTRUCTION TO ENSURE SAME IS CONSISTENT WITH THE LOCAL BUILDING CODE PRIOR TO COMMENCING CONSTRUCTION. DRAINAGE AND UTILITY NOTES (Rev.22021) 1. THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES. 2. LOCATIONS OF ALL EXISTING AND PROPOSED SERVICES ARE APPROXIMATE, AND THE CONTRACTOR MUST INDEPENDENTLY VERIFY AND CONFIRM THOSE LOCATIONS AND SERVICES WITH LOCAL UTILITY COMPANIES PRIOR TO COMMENCING ANY CONSTRUCTION OR EXCAVATION. THE CONTRACTOR MUST INDEPENDENTLY VERIFY AND CONFIRM ALL SANITARY CONNECTION POINTS AND ALL OTHER UTILITY SERVICE CONNECTION POINTS IN THE FIELD, PRIOR TO COMMENCING ANY CONSTRUCTION. THE CONTRACTOR MUST REPORT ALL DISCREPANCIES, ERRORS AND OMISSIONS IN WRITING, TO THE ENGINEER OF RECORD. 3. THE CONTRACTOR MUST VERTICALLY AND HORIZONTALLY LOCATE ALL UTILITIES AND SERVICES INCLUDING, BUT NOT LIMITED TO, GAS, WATER, ELECTRIC, SANITARY AND STORM, TELEPHONE, CABLE, FIBER OPTIC CABLE, ETC. WITHIN THE LIMITS OF DISTURBANCE OR WORK SPACE, WHICHEVER IS GREATER. THE CONTRACTOR MUST USE, REFER TO, AND COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE UTILITY NOTIFICATION SYSTEM TO LOCATE ALL OF THE UNDERGROUND UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ALL DAMAGE TO ANY EXISTING UTILITIES WHICH OCCUR DURING CONSTRUCTION, AT NO COST TO THE OWNER AND AT CONTRACTOR'S SOLE COST AND EXPENSE. THE CONTRACTOR MUST BEAR ALL COSTS ASSOCIATED WITH DAMAGE TO ANY EXISTING UTILITIES WHICH OCCURS DURING CONSTRUCTION. 4. THE CONTRACTOR MUST FIELD VERIFY THE PROPOSED INTERFACE POINTS (CROSSINGS) WITH EXISTING UNDERGROUND UTILITIES BY USING A TEST PIT TO CONFIRM EXACT DEPTH, PRIOR TO COMMENCEMENT OF CONSTRUCTION. 5. STORMWATER ROOF DRAIN LOCATIONS ARE BASED ON ARCHITECTURAL PLANS. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING LOCATIONS OF SAME BASED UPON FINAL ARCHITECTURAL PLANS. 6. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING SITE PLAN DOCUMENTS AND ARCHITECTURAL PLANS FOR EXACT BUILDING UTILITY CONNECTION LOCATIONS; GREASE TRAP REQUIREMENTS; AND DETAILS, DOOR ACCESS, AND EXTERIOR GRADING. THE ARCHITECT WILL DETERMINE THE UTILITY SERVICE SIZES. THE CONTRACTOR MUST COORDINATE INSTALLATION OF UTILITY SERVICES WITH THE INDMDUAL COMPANIES TO AVOID CONFLICTS AND TO ENSURE THAT PROPER DEPTHS ARE ACHIEVED. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT INSTALLATION OF ALL IMPROVEMENTS COMPLIES WITH ALL UTILITY REQUIREMENTS OF THE APPLICABLE JURISDICTION AND REGULATORY AGENCIES AND ALL OTHER APPLICABLE REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES AND, FURTHER, IS RESPONSIBLE FOR COORDINATING THE UTILITY TIE-INS/CONNECTIONS PRIOR TO CONNECTING TO THE EXISTING UTILITY/SERVICE. WHERE A CONFUCT(S) EXISTS BETWEEN THESE DOCUMENTS AND THE ARCHITECTURAL PLANS, OR WHERE ARCHITECTURAL PLAN UTILITY CONNECTION POINTS DIFFER, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IN WRITING, AND PRIOR TO CONSTRUCTION, MUST RESOLVE SAME. 7. ALL FILL, COMPACTION, AND BACKFILL MATERIALS REQUIRED FOR UTILITY INSTALLATION MUST BE EXACTLY AS PER THE RECOMMENDATIONS PROVIDED IN THE GEOTECHNICAL REPORT AND THE CONTRACTOR MUST COORDINATE SAME WITH THE APPLICABLE UTILITY COMPANY SPECIFICATIONS. WHEN THE PROJECT DOES NOT HAVE GEOTECHNICAL RECOMMENDATIONS, FILL AND COMPACTION MUST COMPLY WITH APPLICABLE REQUIREMENTS AND SPECIFICATIONS. ENGINEER OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR DESIGN OF TRENCH BACKFILL OR FOR COMPACTION REQUIREMENTS 8. DURING THE INSTALLATION OF SANITARY, STORM, AND ALL UTILITIES, THE CONTRACTOR MUST MAINTAIN A CONTEMPORANEOUS AND THOROUGH RECORD OF CONSTRUCTION TO IDENTIFY THE AS -INSTALLED LOCATIONS OF ALL UNDERGROUND INFRASTRUCTURE. THE CONTRACTOR MUST CAREFULLY NOTE ANY INSTALLATIONS THAT DEVIATE, IN ANY RESPECT, FROM THE INFORMATION CONTAINED IN THESE PLANS. THIS RECORD MUST BE KEPT ON A CLEAN COPY OF THE APPROPRIATE PLAN(S), WHICH THE CONTRACTOR MUST PROMPTLY PROVIDE TO THE OWNER IMMEDIATELY UPON THE COMPLETION OF WORK. 9. THE CONTRACTOR MUST ENSURE THAT ALL UTILITY TRENCHES LOCATED IN EXISTING PAVED ROADWAYS INCLUDING SANITARY, WATER AND STORM SYSTEMS, ARE REPAIRED IN ACCORDANCE WITH REFERENCED MUNICIPAL, COUNTY AND OR STATE DOT DETAILS AS APPLICABLE. THE CONTRACTOR MUST COORDINATE INSPECTION AND APPROVAL OF COMPLETED WORK WITH THE AGENCY WITH JURISDICTION OVER SAME. 10. FINAL LOCATIONS OF PROPOSED UTILITY POLES, AND/ OR POLES TO BE RELOCATED ARE AT THE SOLE DISCRETION OF THE RESPECTIVE UTILITY COMPANY, REGARDLESS OF WHAT THIS PLAN DEPICTS. 11. WATER SERVICE MATERIALS, BURIAL DEPTH, AND COVER REQUIREMENTS MUST BE SPECIFIED BY THE LOCAL UTILITY COMPANY. THE CONTRACTOR MUST CONTACT THE APPLICABLE MUNICIPALITY TO CONFIRM THE PROPER WATER METER AND VAULT, PRIOR TO COMMENCING CONSTRUCTION. 12. THE TOPS OF EXISTING MANHOLES, INLET STRUCTURES, AND SANITARY CLEANOUT MUST BE ADJUSTED, AS NECESSARY, TO MATCH PROPOSED FINISHED GRADES WITH NO TRIPPING OR SAFETY HAZARD IN ACCORDANCE WITH ALL APPLICABLE STANDARDS, REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES. 1. THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES. 2. THE LIGHTING CONTRACTOR MUST COMPLY WITH ALL APPLICABLE CONTRACTOR REQUIREMENTS INDICATED IN THE PLANS, INCLUDING BUT NOT LIMITED TO GENERAL NOTES GRADING AND UTILITY NOTES SITE SAFETY AND ALL AGENCY AND GOVERNMENTAL REGULATIONS. 3. THE LIGHTING PLAN DEPICTS PROPOSED SUSTAINED ILLUMINATION LEVELS CALCULATED USING DATA PROVIDED BY THE NOTED MANUFACTURER. ACTUAL SUSTAINED SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINAIRES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS, THE SERVICE LIFE OF EQUIPMENT AND LUMINAIRES AND OTHER RELATED VARIABLE FIELD CONDITIONS. 4. THE LIGHTING VALUES AND CALCULATION POINTS DEPICTED ON THIS PLAN ARE ANALYZED ON A HORIZONTAL GEOMETRIC PLANE AT GROUND LEVEL UNLESS OTHERWISE NOTED. ILLUMINATION LEVELS ARE SHOWN IN FOOT-CANDLES FC . ( ) 5. THE LUMINAIRES, LAMPS AND LENSES MUST BE REGULARLY INSPECTED/MAINTAINED TO ENSURE THAT THEY FUNCTION PROPERLY. THIS WORK SHOULD INCLUDE, BUT IS NOT LIMITED TO, VISUAL OBSERVATION, CLEANING OF LENSES, AND RE-LAMPING ACCORDING TO MANUFACTURER RECOMMENDATIONS. FAILURE TO FOLLOW THE ABOVE STEPS COULD RESULT IN IMPROPER LIGHT DISTRIBUTION AND FAILURE TO COMPLY WITH THE APPROVED DESIGN. UPON COMPLETION AND OWNER'S ACCEPTANCE OF THE WORK THE ABOVE RESPONSIBILITIES BECOMES SOLELY THE OWNER'S. 6. THE LIGHTING PLAN IS INTENDED TO SHOW THE LOCATIONS AND TYPE OF LUMINAIRES. POWER SYSTEM, CONDUITS, WIRING AND OTHER ELECTRICAL COMPONENTS ARE SOLELY THE ARCHITECTS, MECHANICAL ENGINEER'S AND/OR LIGHTING CONTRACTOR'S RESPONSIBILITY, AS INDICATED IN THE CONSTRUCTION CONTRACT DOCUMENTS. THE LIGHTING CONTRACTOR MUST COORDINATE WITH THE PROJECT ARCHITECT AND/OR ELECTRICAL ENGINEER REGARDING ANY AND ALL POWER SOURCES AND TIMING DEVICES NECESSARY TO MEET THE DESIGN INTENT. THESE ITEMS MUST BE INSTALLED AS REQUIRED BY STATE AND LOCAL REGULATIONS. CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF LIGHTING FIXTURES AND APPURTENANCES IN ACCORDANCE WITH ALL APPLICABLE BUILDING AND ELECTRICAL CODES. 7. THE CONTRACTOR MUST BRING IMMEDIATELY, IN WRITING, ANY LIGHT LOCATIONS THAT CONFLICT WITH DRAINAGE, UTILITIES, OR OTHER STRUCTURE(S) TO THE ENGINEER OF RECORD'S ATTENTION, PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 8. THE CONTRACTOR IS RESPONSIBLE TO ENSURE THAT SHIELDING AND OR ROTATED OPTICS ARE INSTALLED AS INDICATED ON THE PLAN IN ORDER TO ACHIEVE THE LIGHTING LEVELS THE REVIEWING AGENCY APPROVED. ALBEMARLE COUNTY NOTES 1. ACCESSIBLE PARKING SPACES, ACCESS ISLES, AND ACCESSIBLE ROUTE SHALL BE INSTALLED IN ACCORDANCE WITH ICC ANSI A117.1-09 AND THE 2015 VIRGINIA CONSTRUCTION CODE. 2. ALL WATER LINES, SEWER LINES, AND FIRE LINES FROM THE MAIN TO THE STRUCTURE LOCATED ON PRIVATE PROPERTY MUST HAVE A VISUAL INSPECTION PERFORMED BY THE BUILDING DEPARTMENT. 3. WHERE THE FLOOD LEVEL RIMS OF PLUMBING FIXTURES ARE BELOW THE ELEVATION OF THE MANHOLE COVER OF THE NEXT UPSTREAM MANHOLE IN THE PUBLIC SEWER, THE FIXTURES SHALL BE PROTECTED BY A BACKWATER VALVE INSTALLED IN THE BUILDING DRAIN, BRANCH OF THE BUILDING DRAIN OR HORIZONTAL BRANCH SERVING SUCH FIXTURES. PLUMBING FIXTURES HAVING FLOOD LEVEL RIMS ABOVE THE ELEVATION OF THE MANHOLE COVER OF THE NEXT UPSTREAM MANHOLE IN THE PUBLIC SEWER SHALL NOT DISCHARGE THROUGH A BACKWATER VALVE. 4. ALL ROOF DRAINS SHALL DISCHARGE IN A MANNER NOT TO CAUSE A PUBLIC NUISANCE AND NOT OVER SIDEWALKS. 5. BUILDINGS OR STRUCTURES BUILT BEFORE JANUARY 1, 1985 MUST HAVE AN ASBESTOS SURVEY PERFORMED IN ORDER TO APPLY FOR A DEMOLITION PERMIT. ASBESTOS REMOVAL PERMITS ARE REQUIRED IF POSITIVE FOR SUCH FROM ALBEMARLE COUNTY AND VDOU. CONTACT VDOU FOR THEIR ADDITIONAL REQUIREMENTS AND PERMITS FOR DEMOLITION PROJECTS AT 540-562-3580 X131. 6. A KNOX BOX WILL BE REQUIRED. 7. RETAINING WALLS GREATER THAN 3 FEET IN HEIGHT REQUIRE A SEPARATE BUILDING PERMIT. WALLS EXCEEDING 4 FEET IN HEIGHT REQUIRE A STAMPED ENGINEERED DESIGN. WALLS REQUIRE INSPECTIONS AS OUTLINED IN THE USBC. 8. ALL WATER, SEWER AND FIRE LINES REQUIRE NEW INSPECTION AND TESTING PROCEDURES. THE ACSA PERFORMS ANY TESTING AND INSPECTIONS OF THE PUBLIC SEWER AND WATER MAIN(S). THE ALBEMARLE COUNTY BUILDING INSPECTIONS DEPARTMENT (ACBID) DOES A VISUAL INSPECTION AND WITNESSES THE TESTING OF THE BUILDING DRAIN, WATER SERVICE PIPE AND THE SPRINKLER LEAD-IN CONNECTION. THE DEVELOPERICONTRACTOR IS RESPONSIBLE TO RETAIN A SPECIAL INSPECTOR AS OUTLINED IN THE UPDATED ALBEMARLE COUNTY POLICY FOR SITE UTILITIES TO PERFORM THE VISUAL INSPECTION AND TESTING OF ALL UTILITIES NOT COVERED BY THE ACSA OR ACBID. THIS INCLUDES BUILDING SEWERS, WATER AND FIRE LINE BRANCHES BETWEEN THE MAIN AND THE METER(S)/BUILDING(S). THE SPECIAL INSPECTOR'S REPORT MUST BE SUBMITTED AND APPROVED BY THE ALBEMARLE COUNTY ENGINEERING DEPARTMENT PRIOR TO A CERTIFICATE OF OCCUPANCY BEING ISSUED. W 2 O m 0 Z D_ W W W U) Z F D_ W U O Z � z � _ Z W W H W -U O U D_ Ur ZUJWUJ jW Z�('i~ W �(n FwQ=�wz D><af-j - Z U) < z < M W z F H O pQQQF1Y z O U U) a 0 Q c� Z J (/) � In O7 0 W Z Q (n a J d Q of J F U W H U3 REVISIONS REV i DATE I COMMENT =� 1 110129120211 PER ISP COMMENTS �� 2 01/21/2022 i PER COUNTY I COMMENTS BSC RTY H 3 04/OS/2022 PER COUNTY COMMENTS BSC RTY Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. I I PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: CNDS-2 PROJECT: SITE PLAN DOCUMENTS FOR DIStUMU PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLER// 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@BohlerEng.com TH Lic. No. 0402056625 04/08/2022 SHEET TITLE: GENERAL NOTES SHEET NUMBER: C-102 N0 N O N N m > 0 n % ¢ x REVISION 3 - 04/08/2022 U z 3 W z N w w z 3 a N z z 9 a U U STANDARD DRAWING LEGEND ABBREVIATIONS STANDARD \ WBC ej O Z EE LU Z LU of W Z W = W > W Z m W U Ix W Z } (U' I_ LU Of U)NEIGHBO J Z ) J 1n IS 0) Z) 2 Q Q Z Q Z (n g W Z F H O CIL Of Z< Q F~ O Z J O Q j w Z Q IY Z � D- Q d Q of > J ~ H 3 g cp 8 s o $ g § how gym <&® a y, o p 3s -.B 9a o - FOR ENTIRE PLAN SET LIMIT OF WORK LOW LOW LIMIT OF DISTURBANCE LOD LOD FOR ENTIRE PLAN SET AC ACRES EXISTING NOTE TYPICAL NOTE TEXT PROPOSED NOTE ADA AMERICANS WITH DISABILITY ACT ONSITE PROPERTY LINE / R.O.W. LINE ARCH ARCHITECTURAL BOTTOM OF CURB - - PROPERTYLIINE / INTERIOR PARCEL LINE _ _ BF BASEMENT FLOOR BK BLOCK EASEMENT LINE gL BASELINE BLDG BUILDING SETBACK LINE BM BUILDING BENCHMARK BRL BUILDING RESTRICTION LINE CF CUBIC FEET CONCRETE CURB & GUTTER CURB AND GUTTER CL CENTERLINE CMP CORRUGATED METAL PIPE SPILL TRANSITION CONN CONNECTION DEPRESSED CURB AND GUTTER CONC CONCRETE CPP CORRUGATED PLASTIC PIPE CY CUBIC YARDS REVISIONS UTILITY POLE WITH LIGHT DEC DECORATIVE REV DATE COMMENT CRDSHer DRAwNer �o POLE LIGHT DEP DEPRESSED DIP DUCTILE IRON PIPE 1 10/29/2021 PER ISP COMMENTS DSH RTY TRAFFIC LIGHT DOM DOMESTIC 2 01/21/2022 PER COUNTY COMMENTS BSC ELEC ELECTRIC RTY O UTILITY POLE O 3 04/08/2022 PER COUNTY COMMENTS BSC ELEV ELEVATION RTY EP EDGE OF PAVEMENT 4 �S TYPICAL LIGHT ES EDGE OF SHOULDER ACORN LIGHT EW END WALL EX EXISTING __v_ TYPICAL SIGN FES FLARED END SECTION FF FINISHED FLOOR X PARKING COUNTS Ax FH FIRE HYDRANT FG FINISHED GRADE ; Knowbe below. 11 before you dig. call ALWAYS CALL 811 It's fast. It's free. It's the law. G GRADE GF GARAGE FLOOR (AT DOOR) 170--- — 169------------ CONTOUR LINE 90 87 GH GRADE HIGHER SIDE OF WALL TC 516.4 OR 516.4 SPOT ELEVATIONS TC 516.00 TC 516.00 BC 515.55 MATCH EX 518.02 t GL GRADE LOWER SIDE OF WALL GRT GRATE GV GATE VALVE HOPE HIGH DENSITY POLYETHYLENE PIPE SAN SANITARY LABEL SAN # HP HIGH POINT NOT APPROVED FOR CONSTRUCTION X STORM LABEL X HOR HORIZONTAL HW HEADWALL A SANITARY SEWER LATERAL INT INTERSECTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEWANDAPPROVAL. ITISNOTINTENDEDASACONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. INV INVERT /y UNDERGROUND WATER LINE W LF LINEAR FOOT PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: CNDS-2 E UNDERGROUND ELECTRIC LINE E LOC LIMITS OF CLEARING LOD LIMITS OF DISTURBANCE C UNDERGROUND GAS LINE C LOS LINE OF SIGHT LP LOW POINT PROJECT: SITE PLAN DOCUMENTS FOR M �,,.n D1��®�J LJ�J� - 91 PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 0// OVERRHE D ^vH US LANDSCAPE MAX MAXIMUM T UNDERGROUND TELEPHONE LINE T MIN MINIMUM C UNDERGROUND CABLE LINE C MH MANHOLE MJ MECHANICAL JOINT - — - _ — — _ STORM SEWER OC ON CENTER PA POINT OF ANALYSIS S SANITARY SEWER MAIN S PC POINT CURVATURE � HYDRANT PCCR POINTOFCOMPOUND CURVATURE, CURB RETURN PI POINT OF INTERSECTION O SANITARY MANHOLE O POG POINT OF GRADE O STORM MANHOLE �I I \O PROP PROPOSED PT POINT OF TANGENCY Wm ® METER WATER (� PTCR POINT E TANGENCY, CURB RETURN WV WATER VALVE • PVC POLYVINYL CHLORIDE PIPE B O H L E R I PVI POINT VERTICAL INTERSECTION GAS VALVE PVT POINT OF VERTICAL TANGENCY ® MGAS ETER ® R RADIUS 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA 23146 Phone: (804) 893-8200 VA@BohlerEng.com RCP REINFORCED CONCRETE PIPE TYPICAL END SECTION [:--D RET WALL RETAINING WALL R/W RIGHT OF WAY HEADWALL OR ENDWALL OR S SLOPE LTH p F C� Z N YA R Y .p Lic. No. 0402056625 4, O� 04/08/2022v /pNALE�U O GRATE INLET O SAN SANITARY SEWER SF SQUARE FEET Q� CURB INLET STA STATION STM STORM 0 CLEAN OUT O SAN SIDEWALK TBR TO BE REMOVED O ELECTRIC MANHOLE O TBRL TO BE RELOCATED O TELEPHONE MANHOLE O TC TOP OF CURB TELE TELEPHONE ® ELECTRIC BOX EB TPF TREE PROTECTION FENCE SHEET TITLE: GENERAL NOTES AND LEGEND TW TOP OF WALL ® ELECTRIC PEDESTAL EP TYP TYPICAL UG UNDERGROUND UP UTILITY POLE MONITORING WELL W WIDE W/L WATER LINE SHEET NUMBER: C _ '/ 1 03 I TEST PIT YYY W/M WATER METER t PLUS OR MINUS T\ BENCHMARK ® DEGREE BORING YY REVISION 3 - 04/08/2022 # NUMBER NOTES: 1. THE SUBJECT PARCEL BEING THE LANDS OF MIMOSA, L.L.0 AS RECORDED IN DEED BOOK 1980 PAGE 239, AMONG THE LANDS RECORDS OF ALBEMARLE COUNTY, VIRGINIA AND HAVING A PARCEL ID 06100-00.00-120JO PER THE DEPARTMENT OF ASSESSMENTS. 2. AREA = 57.240 SQUARE FEET OR 1.314 ACRES (M) OR 1.32 ACRES (R) 3. LOCATION OF ALL UNDERGROUND UTILITIES ARE APPROXIMATE, SOURCE INFORMATION FROM PLANS AND MARKINGS HAS BEEN COMBINED WITH OBSERVED EVIDENCE OF UTILITIES TO DEVELOP A VIEW OF THOSE UNDERGROUND UTILITIES. HOWEVER, LACKING EXCAVATION. THE EXACT LOCATION OF UNDERGROUND FEATURES CANNOT BE ACCURATELY, COMPLETELY AND RELIABLY DEPICTED. WHERE ADDITIONAL OR MORE DETAILED INFORMATION IS REQUIRED, THE CLIENT IS ADVISED THAT EXCAVATION MAY BE NECESSARY. 4 APPROXIMATE LOCATION OF UNDERGROUND UTILITIES ARE SHOWN PER PRIVATE UTILITY MARKOUT PERFORMED BY INSIGHT ON 04/12/2021 AND FIELD LOCATED WITH CONVENTIONAL FIELD SURVEY METHODS UNLESS OTHERWISE NOTED 5. THIS SURVEY WAS PERFORMED IN THE FIELD ON 0411312021 AND UTILIZING THE REFERENCE DOCUMENTS AS LISTED HEREON AND DEPICTS BUILDINGS, STRUCTURES AND OTHER IMPROVEMENTS. 6, ELEVATIONS ARE BASED ON NAVD88 DATUM DETERMINED BY GPS OBSERVATIONS. 7. THE PROPERTY IS LOCATED IN OTHER AREAS ZONE X (AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN) PER MAP ENTITLED -FIRM, FLOOD INSURANCE RATE MAP, ALBEMARLE COUNTY, VIRGINIA AND INCORPORATED AREAS AND THE INDEPENDENT CITY OF CHARLOTTESVILLE. PANEL 278 OF 575", MAP NUMBER 51003CO278D. WITH A MAP EFFECTIVE DATE OF FEBRUARY 4. 2005. 8. NO SURVEY OF SUBTERRANEAN STRUCTURES OR INTERIOR SPACES SUCH AS FOOTINGS, FOUNDATIONS, VAULTS OR BASEMENTS WAS PERFORMED AS PART OF THIS LAND SURVEY, AND THIS PLAN SHOULD NOT BE CONSTRUED AS CERTIFICATION TO THE EXISTENCE OR LOCATION OF THE SAME. 9. THERE IS NO RECENT EVIDENCE OF EARTH MOVING WORK. BUILDING CONSTRUCTION OR BUILDING ADDITIONS OBSERVED IN THE PROCESS OF CONDUCTING THE FIELDWORK. 10. THERE ARE NOT ANY CHANGES IN STREET RIGHT OF WAY LINES EITHER COMPLETED OR PROPOSED- AND AVAILABLE FROM THE CONTROLLING JURISDICTION AND THERE IS NO EVIDENCE OF RECENT STREET OR SIDEWALK CONSTRUCTION OR REPAIRS OBSERVED IN THE PROCESS OF CONDUCTING THE FIELDWORK. 11. TREES 3 INCHES DBH AND LARGER SHOWN HEREON WERE FIELD LOCATED BY BOHLER ON 0411312021. 12. THERE ARE NO GAP/GORES OR OVERLAPS BETWEEN THE RIGHT-OF-WAY LINES OF SEMINOLE TRAIL AND THE SUBJECT PARCEL. 13. PARKING: 43 STANDARD 2 ADA 45 TOTAL SPACES 14, THERE ARE NO VISIBLE ENCROACHMENTS EXCEPT AS SHOWN ON THE SURVEY AND LISTED BELOW. ENCROACHMENT IS A LEGAL CONDITION, NOT A MATTER OF SURVEY AND, AS A RESULT. THERE MAY BE OTHER POSSIBLE ENCROACHMENTS AFFECTING THE PROPERTY THAT ARE NOT SHOWN. FENCELINE ALONG NORTHWEST LINE BUILDING ALONG SOUTHWEST LINE SHED ALONG SOUTHWEST LINE 15. PROPERTY HAS ACCESS ALONG SEMINOLE TRIAL-U.S. ROUTE. 29. 16. BOHLER WAS NOT MADE AWARE OF ANY WETLAND DELINEATION PERFORMED ON THE SUBJECT PROPERTIES AND THERE WERE NO WETLAND FLAGS OBSERVED AT THE TIME OF THE FIELD SURVEY. A PHASE 1 REPORT WAS NOT PROVIDED. TITLE NOTES THIS SURVEY IS PREPARED WITH REFERENCE TO A COMMITMENT FOR TITLE INSURANCE PREPARED BY COMMONWEALTH LAND TITLE INSURANCE COMPANY COMMITMENT NO. DC2100643, WITH A CMMITMENT DATE OF MARCH 26. 2021. OUR OFFICE HAS REVIEWED THE FOLLOWING SURVEY RELATED EXCEPTIONS IN SCHEDULE B, PART II: D TERMS. PROVISIONS, CONDITIONS, AND EASEMENTS CONTAINED IN EASEMENT GRANTED VIRGINIA ELECTRIC AND POWER COMPANY RECORDED IN DEED BOOK 271. PAGE 414: MAY AFFECT THE SUBJECT PROPERTY, VAGUE AND INSUFFICIENT INFORMATION IN THE RECORD DOCUMENT. A POLE LINE CROSSES THE SUBJECT PROPERTY AND IS SHOWN. D7 TERMS, PROVISIONS, CONDITIONS, AND EASEMENTS CONTAINED IN EASEMENT GRANTED VIRGINIA TELEPHONE AND TELEGRAPH COMPANY RECORDED IN DEED BOOK 278, PAGE 28; MAY AFFECT THE SUBJECT PROPERTY, VAGUE AND INSUFFICIENT INFORMATION IN THE RECORD DOCUMENT. A POLE LINE CROSSES THE SUBJECT PROPERTY AND IS SHOWN. 8. TERMS. PROVISIONS, CONDITIONS, AND EASEMENTS CONTAINED IN EASEMENT GRANTED LBEMARLE COUNTY SERVICE AUTHORITY RECORDED IN DEED BOOK 1315. PAGE 263: MAY AFFECT THE SUBJECT PROPERTY, THE INCLUDED PLAT IS NOT READABLE. TERMS, PROVISIONS, CONDITIONS, AND EASEMENTS CONTAINED IN EASEMENT FOR SLOPE MAINTENANCE AS SHOWN ON PLAT RECORDED IN DEED BOOK 670, PAGE 275; AFFECT THE SUBJECT PROPERTY, APPROXIMATE LOCATION OF EASEMENT IS SHOWN. 10 TERMS, PROVISIONS, CONDITIONS, AND EASEMENTS CONTAINED IN EASEMENT FOR DRAIN INLET AND PIPE TAKEN BY THE COMMONWEALTH OF VIRGINIA BY CERTIFICATE RECORDED IN DEED BOOK 1277, PAGE 279, CONFIRMED BY ORDER RECORDED IN DEED BOOK 1298, PAGE 370, MAY AFFECT THE SUBJECT PROPERTY, REFERENCED HIGHWAY PLAT BOOK XI, PAGES 350 & 351 NOT PROVIDED. 11 RIGHTS ASSOCIATED WITH UTILITY POLES AND OVERHEAD UTILITY LINES AS SHOWN ON PLAT RECORDED IN DEED BOOK 445, PAGE 399: THIS DOCUMENT DOES NOT CONVEY RIGHTS OR CREATE EASEMENTS. Q2 TERMS, PROVISIONS, CONDITIONS. AND EASEMENTS CONTAINED IN EASEMENT(S) AND RIGHTS GRANTED BY CERTIFICATE OF TAKE RECORDED IN DEED BOOK 4594, PAGE 14; AS AMENDED BY AMENDED CERTIFICATE OF TAKE RECORDED IN DEED BOOK 4935, PAGE 537 IN THE CLERK'S OFFICE OF THE CIRCUIT COURT OF ALBEMARLE COUNTY, VIRGINIA; AFFECT THE SUBJECT PROPERTY, EASEMENTS ARE SHOWN. TITLE DECRIPTION ALL THAT CERTAIN LOT OR PARCEL OF LAND, TOGETHER WITH ALL IMPROVEMENTS THEREON AND APPURTENANCES THERETO BELONGING, CONTAINING 1.32 ACRES, MORE OR LESS, SITUATED ON THE WEST SIDE OF U.S. HIGHWAY NO. 29, IN THE CHARLOTTESVILLE MAGISTERIAL DISTRICT OF ALBEMARLE COUNTY, VIRGINIA, WITH A FRONTAGE ON SAID HIGHWAY OF 153.15 FEET, AND RUNNING BACK BETWEEN PARALLEL LINES 366 FEET ON THE NORTHWESTERLY SIDE AND 396.9 FEET ON THE SOUTHWESTERLY SIDE TO A REAR WIDTH OF 150 FEET, AS SHOWN ON A PLAT THEREOF MADE BY WILLIAM S. ROUDABUSH, JR., DATED JUNE 17, 1968, OF RECORD IN THE CLERK'S OFFICE OF THE CIRCUIT COURT OF ALBEMARLE COUNTY, VIRGINIA, IN DEED BOOK 445, PAGE 399. UTILITIES: THE FOLLOWING COMPANIES WERE NOTIFIED BY DELMARVA MISS UTILITY SYSTEM (1-800-552-7001) AND REQUESTED TO MARK OUT UNDERGROUND FACILITIES AFFECTING AND SERVICING THIS SITE. THE UNDERGROUND UTILITY INFORMATION SHOWN HEREON IS BASED UPON THE UTILITY COMPANIES RESPONSE TO THIS REQUEST. SERIAL NUMBER(S): A008301604-00A UTILITY COMPANY LOCATE STATUS PHONE NUMBER ALBEMARLE-WATERS SEWER MARKED (434)531.0714 RIVANNA-WATER 8 SEWER NO CONFLICT (434) 906-2620 CENTURY LINK MARKED (601)364-1063 COMCAST NO CONFLICT (8(4) 562-3861 FIBERLIGHT MARKED (240) 315.8817 MCI MARKED (600) 289-3427 OWEST GOVERNMENT MARKED (703) 387-9152 DOM ELEC MARKED (804) 385.1126 CHARLOTTESVILLE GAS MARKED (804)9214516 LANDS N/F MPS, INC. D.B. 5476 PG. 471 PIN- 06100-00-00-72000 N4T 25'410E 150.00'(M) N52.49'040E--- 150.00'(R) BLOC 15 SOUTHWEST' � �OF � SUG7TNWEJT OF e LANDS N/F S S C ACQUISITIONS INC. O.S. 1429 PG. 330 PIN.- 06100-00-00-12001 UP N01 LANDS N/F SULLIVAN, W/LLIAM EL9 WARD & ✓OHN A F D.B. 1095 PC. 297 (917PIN.- 06100-00-00-120W0 ,480 \ / 0 \ APPROXIMATE LOC,4)70N OF SLOPE EASEME\ OB 670 PC. PG 0.7017 NT 5 / I_I Yam' LANDS OF MIMOSA, L. L. C. 0.9. 1990 PC. 239 AREA: 1.32 AC. (R) 57,, 240 S.F. 1.314 ACRES (M) PIN: 06100-00-00-120✓O 00 NAIL SET ELEY=49918 CLEARANCE-N BAR ORrYE FHR41 MENU N J917,125 LAN05 N/F WILCOHESS LLC, 0..S 9682 PC. 130 PIN' 06100-00-00-12000 UP W/ %BANS C N01 LANDS N/F CHARL07TESVIZZE ALSEMARLE RENTAL PROPERTIES LLC D.B. 5040 PG 206 PIN- 06100-00-00-120PO r+ • V mR� 19'o 00 yQ = ItRooraR �00 M1c,H ym y p GREENFIELDLN 0 n MyERS OR eFq m Q. HCPR� i, CNN ty � J o ,��,..: �.. 7g Oq �074 3 ;#moo k D SITE O M4(f.S DE rORE5T n74p��0 m0 S F 00 Noe O tl r pW �- i LIle Ex ETER CT IV � 9�oFREE N � NOR �P _ R,,,,,rpL,nn OR LOB SYCAMORE CT . - EFItLb PO G42 NpK s IPs /.$E �0 ci w,Lol�.n, �, roq J/ 19 Ml" c _ Cr_, LOCATION MAP COPYRIGHT 2009 DELORME STREET ATLAS USA 2009 LEGEND SCALE: 1'=2000' WM EXISTING CONTOUR ® WATER METER X IZ9.4` EXISTING SPOT ELEVATION ®M GAS METER �- SIGN X TC 12.45 i- EXIST. TOP OF CURB ELEVATION MAIL BOX X C 12295 EXIST. GUTTER ELEVATION • BOLLARD X EP 12J 45 EXIST. EDGE OF PAVEMENT ELEVATION wN FENCE m WATER VALVE OH - OVERHEAD WIRES __ =CI AREA LIGHT C APPROX. LOC, UNDERGROUND CABLE LINE PER UTILITY MARKOUT CLEAN OUT G APPROX. LOC. UNDERGROUND GAS LINE PER UTILITY MARKOUT PAINTED ARROWS N APPROX. LOC. UNDERGROUND WATER LINE PER UTILITY MARKOUT DENOTES PARKING SPACE COUNT f APPROX. LOC, UNDERGROUND ELEC. LINE PER UTILITY MARKOUT GUY WIRE APPROX. LOC. SAN, LATERAL PER UTILITY MARKOUT 1 1 TREE (SIZE AS NOTED) S7 (7YP) TYPICAL \ S PLUS OR MINUS (M� MEASURED \ (R) RECORD O TITLE REPORT EXCEPTION / 4i:__1 BENCHMARK / \ @ PROP. CORNER TO BE SET ® // URB INLETT UTILITY POLE ;61 ATE ZOCA17ON Of // RIM=502 u iN 1/ALRY EASEMENT bW=49550 �} ELECTRIC METER 14594 PG 25 // r.5 ELECTRIC BOX / / ® SANITARY MANHOLE ® STORM DRAIN MANHOLE .Y--CUT IN S9fftK LLET<=500.20 �SAN/TARY MANHOLE NO ACCESS R/M=500QS FOR INFORMATIONAL CURB /NLE7 R/M=49934 /NV=49524 PURPOSES ONLY 11 REVISED CERTIFICATION CJT 05/26/2021 No. I DESCRIPTION OF REVISION BY: DATE TO THE REINALT-THOMAS CORPORATION, A MICHIGAN CORPORATION, HALLE PROPERTIES, L.L.C, AN ARIZONA LIMITED LIABILITY COMPANY, MIMOSA L.L.C.. A VIRGINIA LIMITED LIABILITY COMPANY AND COMMONWEALTH LAND TITLE INSURANCE COMPANY: THIS IS TO CERTIFY THAT THIS MAP OR PLAT AND THE SURVEY ON WHICH IT IS BASED WERE MADE IN ACCORDANCE WITH THE 2021 MINIMUM STANDARD DETAIL REQUIREMENTS FOR ALTAMSPS LAND TITLE SURVEYS, JOINTLY ESTABLISHED AND ADOPTED BY ALTA AND NSPS, AND INCLUDES ITEMS 1, 2. 14, 5, 7(A), 7(B)(1), 7(C), 8, 9. 10, 11(B), 13, 14, 16, 17, 18, 19, & 20 OF TABLE A THEREOF. THE FIELD WORK WAS COMPLETED ON APRIL 13, 2021. ��PyTH OF G f,P .IF =o ERIC NISKANEN Y Lic. No. 1524-B ERIC K. NISKANEN "/:f'mv1 v,6 VIRGINIA LICENSED LAND SURVEYOR NO. 1524-B ALTA/NSPS LAND TITLE SURVEY DISCOUNT TIRE CHARLOTTESVILLE 1636 SEMINOLE TRAIL CHARLOTTESVILLE MAGISTERIAL DISTRICT ALBEMARLE COUNTY, VIRGINIA BOHLER // �Z1`�V°995_oRIVI SUITE 700 S V 21 120 1 HERNDON, VIRGINIA 20170 703.70.709.9500 GATE wWw.boNe2n11meemlgc0m 21 04/2D/21 MNPS'A1EtFY.VO.FUSCSTO4,1/AMNE,V YORO(EfRCMIVARREN. WEINPDELMIA9DUMERNNJOLEHPGNVA"D PAM SOUTEASTERNP4 ■54TMCRE MD•S]UTI604NWriANDBNORINERNVWGIWNWA5-0NGTLN. CC 110ENTRAL WrNU,MG41RLOTTE, W G RALEIGH tNONE FIELD DATE CREW CHIEF DRAWN I REVIEWED I APPROVED SCALE DWG. NO. 1"-20 04/13/21 JK/WL CJT EKN JSF 1" = 20' C-201 0 2 w 0 0 w W/LANDSNF \ SULL/VAN, LL/AM EDD & ✓OHN A F I D.B. 1095 10G. 2J7/ r � 06100-0-00— PIN.- 00-12-120rY0 \ \ \ \ ZONED. HC�H/GHWAY COMMERC/ALJ , / \ US COMMERC/AL , \ / \ ,ll`,3917,480 N 0 q VA44NOS NSF MP49 INC.D.B. 5 \ 5476 PG. 471 _�� /SnNG TREES P/N.• 06T00-00-00-12000 r "OD'/ \ W E (7BRJ (�J / ZONED. HC (H/G//WAY COMMERC/ALJ oz/G,�;xsitm _ \ 8 USE- WAREHOUSE o Li0000, ll I 1; siaax- ---------------- - \\ ! / x o �-(�Y y� 0 -_-_- \ / ; O APPROX/MATEL4CAT/ON OF - \ \ \ -� ♦_, I V fff !! I� 5� , - \ SCOPE MALNTENANCE EASEMENT EX. FENCE \\ �� - -,� _ -_ �- _ ho OB 670' PG. 0275 / \ `soo SOUTN OF �' S -1 ` I �� "i5Y 50 ?cam x".-a `_._- --__-_ _-- --_-- _--- 507 \ \ q s 555 :�---LANDS OF �XLrnNcEEsj / `:---------- i / MIMOSA, L.L.C. SOQ- \ O�� �779T�� I _�$Oh .♦ / D.B.1980PG.239 ------------- ----- �! S WOOD AVA41 7BR 06 '\� ------ -- �. / I ( J 5 1 ♦ \ / AREA: 1.32 AC. (R) </ BARN-\ 1 ♦ t l— — _ / 57,240 S.F. 1.314 ACRES (M) \ / PIN:06100-00-00-120JO ♦ -- \` LANDS N F ♦ ! r EX/SI/Nh TREES (TBR I_ ; 5 i ♦ _ CHARLOTTESV/LLE ALBEMARLE snsx 'J o \\ � �^� ♦\ / .. ..---- - -- ,.y' x9�1 \ ---------------- RENTAL PROPER./ES LLC /., 1 - ! ) , / G \/�, •;� D.B. 5040 PG. 206 \ -_ P/N.06100-00-00-120PO ! \ GRA4EC ANDS MEN. ,, j J, ` i ♦♦ 1(" —lC ZONED. H��H/GHWAY COMMERC/ALJ, ' RLMNANIS R / xsYg� r �rT / ((( o , Y- / A� U COMMERC/AL -_ soffit- _V 'si v� �xsice E(7YR) ATREES (TBRJ � A\l7y�/ rr \ EX/STING TREES (7BR) l '�> / �, ,�\ GMMp) !oD DECK (TBRJ ! ��7� / r I �h�i-� `V : lh WOODS PS (TBR) s/Qal i \ x EXIST/rYG— i EEs \ ' < SM / IRNG SOT FRAME (TBRJ \♦ / l \ l (7BRJ(J 1 STORY / r aza! �v V V\� AV - ♦ ,1 �- l 1 BENCHMARK O BE i ,` �� 1 6F \ \ \ -------- 'A' •\ .\ \\ ,�/ I / Q' LAW/. (�J (fWJ RESET PR/[ TO l \ 1 S>'PR �;�uE \ I \1 y0�jt \//� / \ I LAND D/SIUR94NCEJ Ilk ♦ \ ""'"\ \ Y \ I ,,��QQCf' / N - k AM0IV41L SET % LX TRANSFORMER / il' / / ` /ryas ELEY=499. >8 / x4W,s \ 1J \ \ \ , , , , , , 1 , , , I 1 , 1 �1 I 1 , 1 , 1 1 , , 1 '1, II 1 , , , I , , 1 , 1 II I I I, (mJ I Oil / \y a �1 Lu / _ / alvG TRLFS mp) SOUTHWEST \ \ `�_C`� / 1 ! 11/ / 70 M11 i 'SIR/PING Q ` OF If 11 .-"� '� ,AND I ♦ \� �:; \ I ' ANRK/NGS FF 51305 \ �, ii �g°�11 �� �RJ G' l "♦,( \. VA`", \ " 5 , I , r \Vi s 1,�TNW)`sk \`JI " !m it / \ II " ♦ /\ \ ?> : l8 /` *ss \`� \ RlM so233 VV ;-� \ \yv ��" j / c+♦ I \ \ \ \ /NV 495.50 I d// Y C ICJ � ♦ �� v J X' UNOERGROUNO�"� .`�G l /♦vim♦ `A�`'-- ---- \ Y 4Ws \\I/ENV (IBRJ dl..a \j\ ,//�i I I i G ��� \\ �, EX. CCEAN ♦♦ \ za�e _ FY(PSTN NAY tSEMENT ' OUT (TBR) l �♦Q Qd . 4594 fl� 25 / I fV CONCIft j f 20' V EX. 645 ♦♦/� \ METER (TBR) �` O �E� ' /A I " -SGU� \\ \ \o ♦ l lrr�ss \\� ` o/ \ I EX. ELEC. 'o \ � � EONC \� \ 1V>Ep mm METER (TBRJ I\ \ t�� l ♦♦ -4 STNRS w ONOERGROUNO Fq� /� 24 RCP c mzlr 1., • M \\ ECEC. (TBRJ ` EXfSDNG TREES (78R)\\ y\, \ T •� /caxn l � T vv l \\ oe< 1 5A21f1 BUILDING 7YENOYS" �"o„ EX CURB INLET J AVA axs J,J51 S.F. (IBRf m R , Soli - I NO wvv RMAg sns y a RIM=Svo. LAND N F )� o vv l l --- \ /N11 49200 / • ♦ C cAERB S ♦ o/ \� (\ (SEA DEMO NOTE 4) saN \ ,c ra sr S S C ACOU(S/T/ONS /NC. A \ vv 20 4w \\ A I I \ c aK / c ors TARP MANHOLE D.B. 1429',PG. JJ0 \ \ `\\ \\ � aD0 RM=494� I I CONC.IYACK R PIN.- 06100-00? 00-120Q1 \ °o/ \�\ l l \\ a ° \ \ ''/ CURB /NLE7 ZONED. HC H/GHWAK COMME/�G/AL 1 \ — \\ �\ \ \� S"/ RiM=499J4 / \\\ / / � Z1 oyl I \. !/ J LNV=49000 USE.• SELF STORAGE ,o \o \ ( c (7H)— (SEE oEMO NOTE 4) I / (J G TREES (IBR) \�\. CANOPY RJYYY-' \ i' \ sl6iar , :o PROP S4W CUT IRON ROP OQ , � /.� (�) ♦\ A A �', l��tl i °Azm I1 f0UN0 0 \\ ( J 5� Fl 1�iCCONCL/OJ \ ! o -_- �` 494.91-- 'xraslr \ / OOT 1-1vv �� \ \ \,C ! O�A�i /nb APPROX/MOTE ZOCAAON OF - //ki/ PERMANENT DRAINAGE EASEMENT ' 1�.99 D.B. -- 4594 PG. 25 \ SLOG / -- ----- --- NG9 ----------- (mil ;/! \�\� syvx ,50 C . ool 50/ \ \��\ I i2g 49J5 ----------- -- po - i \ crttz! c LOff NT .82 /// 514 ---- \\\f / �l RIM= /N \ \.� _-------- --- /\� \ --_ ' 4gB ---- --- 4 � ,,,, 501 \ - � DNC. C-& GUTTER p \ O 4i � R ✓- - ---°� ----- 0 0 �iarar,� % �� CONC INK 9RJ _ O a •u _ / /l�1Pji 7 c� t J917,125x.b95 A-`� I \ 0 �! NJ,917,125 All ----- DEMOLITION NOTES: 1. ALTNNSPS LAND TITLE SURVEY ENTITLED "DISCOUNT TIRE CHARLOTTESVILLE" PROVIDED BY: BOHLER 12825 WORLDGATE DRIVE SUITE 700 HERNDON, VA 20170 DATE: 01/20/2021 DATUM VCS NAD8312011 SOUTH ZONE ELEVATIONS: ARE BASED ON NAVD88 DATUM DETERMINED BY GPS OBSERVATIONS 2. ADDITIONAL TOPOGRAPHICAL INFORMATION OUTSIDE OF PROPERTY BOUNDARY IS BASED ON ALBEMARLE COUNTY GIS CONTOURS. 3. WATER/SEWER SERVICES WILL BE REQUIRED TO BE DISCONNECTED PRIOR TO DEMO PERMIT APPROVAL. 4. EXISTING STORM SEWER INVERTS AND PIPIE INFORMATION OBTAINED FROM PREVIOUSLY APPROVED WENDY'S PLAN BY HAMILL AND MCKINNEY ARCHITECTS AND ENGINEERS DATED NOVEMBER 14, 1983. 5. LOCATION OF EXISTING GREASE INTERCEPTOR IS UNKNOWN. 6. CONTRACTOR IS RESPONSIBLE FOR COORDINATING GAS, ELECTRIC, AND TELECOM SERVICES TO THE STORE. 7. CONTRACTOR RESPONSIBLE FOR MAINTENANCE OF PEDESTRIANNEHICULAR TRAFFIC DURING CONSTRUCTION ACTIVITIES. 8. CONTRACTOR TO COORDINATE WITH ALBEMARLE COUNTY ON STREET LIGHT POLE RELOCATION FOR MATERIALS, SPECIFICATION, AND PROCESS. CONTRACTOR TO RESET NORTHEASTERN MOST EXISTING STREET LIGHT POLE IF REQUIRED DUE TO SIDEWALK CONSTRUCTION IN THE VICINITY OF THE EXISTING POLE. 9. OVERHEAD UTILITY LINE IS TO REMAIN. IT IS WITHIN CLOSE PROXIMITY TO THE EXISTING BUILDING. CARE TO BE TAKEN DURING CONSTRUCTION AND DEMOLITION. CONTRACTOR TO COMPLY WITH LOCAL, STATE, AND NATIONAL REGULATIONS FOR WORKING WITHIN CLOSE PROXIMITY TO OVERHEAD UTILITY LINE. DEMOLITION / REMOVAL LEGEND DEMOLITIONIREMOVAL NOTE TYPICAL NOTE TEXT ----------------- EASEMENT LINE CONCRETE CURB& — -- — — — — — — GUTTER UTILITY POLE WITH LIGHT POLE LIGHT TRAFFIC LIGHT UTILITY POLE TYPICAL f ) LIGHT 4 h" ACORN LIGHT ---�-- TYPICAL SIGN /^\ X� PARKING L COUNTS SPOT TC576,4 OR jrE! ELEVATIONS mSAN SANITARY # LABEL STORM # LABEL _____-SLI--___-_ SANITARY SEWER LATERAL _______y/_______ UNDERGROUND WATER LINE E _______ UNDERGROUND ELECTRIC LINE 0_______ UNDERGROUND GAS LINE ____---OH _______ OVERHEAD WIRE _______T_______ UNDERGROUND TELEPHONE LINE _-----_D_-----_ UNDERGROUND CABLE LINE ______ STORM ______ SEWER _______S _---___ SANITARY SEWER MAIN HYDRANT 1`S I SANITARY MANHOLE (�� I STORM MANHOLE yyM WATER ® METER WV WATER x VALVE ❑ GAS VALVE ® GAS METER LIMITS —LOD LOD— DISTURBANCE ALBEMARLE COUNTY MANAGED SLOPES r LANDS N/F STORM MANHOCE(7BR)^ bti• W/LCOHE55 LLC, �r '= h \ l 1 c n R/M=m..86 F / — D.B 3682 PG. 130 r __ a° \ 1 INYA=4485.11 y _ — qx 06100-00-00-12000 �'� 'TRNo `,/ ; ! �� EX SMEEr LOW G,� y�Poa� -- LEGEND / USE. /FUEL STAT/ON \ _ `.\ l / (h�pLJ ZONED HC GHWAY COMMERC/ 01 E[Ec �J \ _ _ . _ _ . _ _ . _ PROP sAwcur / - ALJ \J ce'' o / i' / l ! / / � 80X (79RLJ G�� ����l rt /•' ' i�(,U\ 0�1 NO LOW —LOW` LIMIT OF WORK "1 _ _ % . 1'� p� R/M=494.51 \ /TX P h� -Ne CURB INLET �Q F' LOD LOD LIMIT OF DISTURBANCE R/.1R9 I 19 � �P �0 P�� \J SPCONC N "PROP sAW CUr '� N WALK \ \y -„ -Lrcc `mil_ h'YORANT 20 10 5 0 20 ------------------- x e9J.11 20' 0 z EE w w w Z F W W W Z LU LU W U) U p:W<= W Z)2U)< Qz zU)WQZF Z J 0 � Of J O Z d J O O w H REVISIONS REV DATE COMMENT 1 10/29/2021 PER ISP COMMENTS 2 01/21/2022 PER COUNTY COMMENTS 3 04/08/2022 PER COUNTY COMMENTS Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: DEMO -2 PROJECT: SITE PLAN DOCUMENTS FOR oiscouNt PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@BohlerEng.com rF_ALTH e21 Lic. No. 0402056625 6, 04/08/2022 j SHEET TITLE: EXISTING CONDITIONS AND DEMOLITION PLAN SHEET NUMBER C-203 REVISION 3 - 04/08/2022 U:*4 LANDS N/F MPB, INC. D.B 5476 PG 471 PIN 06100-00-00-12000 r� lk ZONED• HC (h'/GHWAY COMMERC/AL) USE WAREHOUSE UP lvw% SITE LIGHT ry& F2 a v� tia 2y, LANDS IV S S C ACQUISITIONS INC. D. B 1429 PG 330 ,PIN.- 06100-00-00-120D7 ZONED: HC (HIGHWAY COMMERC/AL) USE SELF STORAGE z 3 / �v j OP STRIPING FORD LOADING SPACE 237 LANDS NS�F SULLIVAN, W/LL/AM EDl4ARD & ✓OHN A D. F / B 1095 PG. FIN.- 06100-00-00-120W0 ZONED: HC rH/GHINAY COMMERCIAL) USE: COMMERC/AL N ,J917480 i h a � � W 20P VDOT GR-2 / JARDRAIL KEYSTONE RETAINING WALL WITH SAFETY RAILING \ COLOR: PALOMINO (MAX. HEIGHT: 4') TO BE DESIGNED BY OTHERS PROP TRASH ENCLOSURE APPROX/MATE LOCATION OE \ (SEE ARCH) SCOPE MAINTENANCE EASEMENT D.R. 670 PG. 0275 v o LANDS N/F CHARLOTTESV/LLE ALBEMARLE \ RENTAL PROPERTIES ZZC D.B 5040 PG 206 10R P1N. 06100-00-00-120RO ` JOR ZONED HC - C01VIAY COMMERC/AL) \ USE: COMMERC/AL GM \ tia \'9 2.7'R PROP. WALL MOUNTEDSITE \ (SEE LIGHTARCH(TMP) '( ROP. KEYSTONE RETAINING WALL COLOR: PALOMINO (MAX HEIGHT:0.9') op6 BY OTHBE ERS GNED 0 \ ROP. SITE AREA = 1.32 AC (R)1.314 (M) DELIVERIES OWED Hit O CURB INLET 00 0 � R/M=50293 PROP. ELECTRICAL /NV=49550� CABINET (SEE ARCH) A 7,680t SF p ROP. WING WALL / 27 SPACES REQUIRED (SEE ARCH) \\\ \ 32 SPACES PROVIDED IN \/> CLUDING 2 ADA GARAGE '��' EXS�NG UF7E5EME T DOORS 88/4594 PG 25 • r- PROP. ROOF •'sl. /0 SIGN MOUNTED f 20' _ MECHANICAL O o EQUIPEMENT �\ o (SEE ARCH) d CONC PROP. BOLLARD d' P e v •- MOUNTED ADA _ STAIRS PARKING SIGN - 5Q- UP W� \ / - vm ROP WHEEL STOP TRgNs NO, NO ('C J�' RCP (TYP) v °R7y o0 `� HRII' OP A RAMP � ?y, �5P p4� �P�`F � J �� 1 - �pP 0p sAl. PROP KEYSTONE i & Gl/TTER RETAINING WALL �� pp'a / , O� \� \ 9 O / Cpzy, CONC CURS WITH RAILING J / COLOR: PALOMINO (MAX. HEIGHT- TOBE ESIGNED BY OTHERS IRON ROV�l ti pJ FOUND \ i oy PROP. SITE AREA =1.32A\�\ (R)1.314 (M) l� SIGN °0 / q N 9917129 EX. ID SIGN TO BE REFACED.— 20 " LANDS N/F / ICY/LCOHESS LLC, °oJ / \ \ PP. S71 sh P/N 06100-00-00-12000 ZONED HC (HIGHWAY COMMERC/AL) ! / USE FUEL STATION / l/P NOy"� —ON OH T P/- UP W/ TRANS NOj CONC. / o0 PROP. 2' / CURB CUT / K3 b ROP. CG-12 , • \' % . PROP. CG-12 p. ERO RELOCATED AN174 MANHO�G��o �P LE R/IV-49451 RM8 4 19 '•� yj��p �p,�OQ��O /NV-4B699 SAW CUT �O�vPOQ�� �� e G P�' 'ARY MANHOLE FE DEMO NOTE 4) SAW CUT N J917,125 ESSEMENT 2D 10 20 1 "= 20' SIGNAGE NOTES: SIGNAGE PACKAGE PROVIDED BY: WALTON 10101 REUNION PLACE SUITE 500 SAN ANTONIO, TX 78216 ENTITLED: DISCOUNT TIRE VAC 12457 DATED: 10/15/2021 PROJECT: CID318719-BDG SITE DATA INITIAL SITE PLAN NUMBER SPD202100054 ADDRESS 1636 SEMINOLE TRAIL CHARLOTTESVILLE, VA OWNER MIMOSA LLC PO BOX 7652 CHARLOTTESVILLE, VA 22906 DEVELOPER HALLE PROPERTIES, LLC C/O DISCOUNT TIRE 20225 N. SCOTTSDALE ROAD SCOTTSDALE, AZ 85255 TMP 06100-00-00-120JO JURISDICTION ALBEMARLE COUNTY MAGISTERIAL DISTRICT RIO DISTRICT ZONING PROPOSED USE TIRE SALES EXISTING HIGHWAY COMMERCIAL - HC PROPOSED HIGHWAY COMMERCIAL - HC ZONING OVERLAY DISTRICT AIRPORT IMPACT AREA AND ENTRANCE CORRIDOR SITE AREA 1.32 AC BUILDING AREA 7,680 SF BUILDING AREA PERCENTAGE OF SITE AREA 12 96% MAXIMUM BUILDING HEIGHT 65 FEET PROP. BUILDING HEIGHT 26 FEET (1-STORY) PROP. IMPERVIOUS COVER OF SITE AREA 1.06 AC (80%) PROP. OPEN SPACE 0.26 AC (20%) PARKING REQUIRED 1 SPACE PER EMPLOYEE PLUS 2 SPACES PER SERVICE BAY=(1`15)+(6'2)=15+12=27 SPACES MAXIMUM PARKING ALLOWED: NO MORE THAN 20%THE REQUIRED = (27*120%) = 32 SPACES PARKING PROVIDED 32 SPACES HANDICAP 2 SPACES (1 VAN SPACE) REQUIRED BUILDING SETBACKS FRONT YARD(SEMINOLE TRAIL) MINIMUM SETBACK 10 FEET SIDE YARDS(NORTH AND SOUTH PROPERTY LINES) N/A PROVIDED BUILDING SETBACKS FRONT YARD(SEMINOLE TRAIL) 3 103.9 FEET SIDE YARDS(NORTH AND SOUTH PROPERTY LINES) NORTH: t 35.6 FEET SOUTH t 53.2 FEET REQUIRED LAND BUFFERS FRONT YARD(SEMINOLE TRAIL) N/A SIDE YARDS(NORTH AND SOUTH PROPERTY LINES) N/A HATCH LEGEND PROP BUILDING (SEE ARCH DRAWINGS) BRICK CROSSWALK LEGEND LIGHT DUTY ASPHALT PAVEMENT 8 CONCRETE PAVEMENT o e AREA OF WP-2 OVERLAY --•--•--•— PROP SAWCUT _LOWLOWI— LIMIT OF WORK LOD LOD LIMIT OF DISTURBANCE NOTES: 1, SEE SHEET C-102 FOR GENERAL NOTES AND SHEET C-103 FOR LEGEND, 2. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. O z EE W W W UW)Z F W(DWWU)wW WW(DZ� jWW z_rCJ�WWO ~Wax Wz > z 0 W 0 0 a)Z)MaQZQ zU)MWZF� zof 00 Q J IY z W Z z o Q a-J of O O W H U7 REVISIONS DI REV DATE COMMENT CH 1 10/29/2021 PER ISP COMMENTS 2 01/21/2022 PER COUNTY COMMENTS 3 04/08/2022 PER COUNTY COMMENTS Know what's bBIOW. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: SITE -2 PROJECT: SITE PLAN DOCUMENTS FOR olscouNt PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@BohlerEng.com rF_ALTH e� Lic. No. 0402056625 04/08/2022 SHEET TITLE: SITE PLAN SHEET NUMBER: C-301 REVISION 3 - 04/08/2022 EX R.O.W. SEMINOLE TRAIL 2% 1 0 U w 0 U N z Z 3 a w J w z 3 05 N z z 0 U SIDEWALK OFFSITE LANDSCAPING 1 1 0 IN 1 1 PROP. ON -SITE LANDSCAPING I PARKING STALL m co DRIVE AISLE I PARKING STALL GRADE ABOVE) 5%MAX r EXISTING GRADE l STOP 11 SIDEWALK FOR INFORMATIONAL/SCHEMATIC PURPOSES ONLY. THIS SHEET NOT TO BE USED FOR CONSTRUCTION, BUILDING z a W W W to z rW W z W19w5W Z W W j W zrC�t=ohm FWa= Wz J>zUWtnO r=n S a Q z Q zcn<2Wz_F'W 0zaQa~O Q J WD� W Z z as J o a of J F U W I— tn REVISIONS F=528.85 = 500.85 REV I DATE I COMMENT 1 10/29/2021 PER ISP COMMENTS 2 1 01/21/2022 PER COUNTY COMMENTS 3 04/08/2022 PER COUNTY COMMENTS 15 Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY Gj r sO�r DATE: 10/29/2021 CAD LID.: SITE-2 PROJECT: sk SITE PLAN DOCUMENTS °° a° °44° 4°43 °°° ° °1°° °, ° a ° °7 14°° 4 Ci W-MI►S-=n��Rfli >� — - - - - - — - - o- - — - - — - - - - - 20 10 20 I1"= 20' FOR oiscoumv PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@BohlerEng.com TH Lic. No. 0402056625 04/08/2022 SHEET TITLE: SITE CROSS SECTION SHEET NUMBER: C-302 REVISION 3 - 04/08/2022 ULANDS N/F MPB, INC. D.B 5476 PG 471 PIN 06100-00-00-12000 ZONED• HC (HIGHWAY COMMERC/AL) USE WAREHOUSE 3 9\ SITE LIGHT ryF: R3 tia Pp ryph 2y, LANDS NIF S S C ACQUISITIONS INC. D. B 1429 PG 330 ,PIN.- 06100-00-00-120D7 ZONED: HC (HIGHWAY COMMERCIAL) USE SELF STORAGE /ZZ LANDS NV�F / SULL/VAN, W2. 1 EDl10C. & ✓OHN A F / D. B 1095 PG. 237 FIN.- 06100-00-00-120WO ZONED: HC rH/GHWAY COMMERCIAL) USE: COMMERCIAL `1h \ / ROP. KEYSTONE RETAINING \ / WALL WITH SAFETY RAILING COLOR: PALOMINO (MAX. HEIGHT: 4') TO BE DESIGNED BY OTHERS �0 APPROX/MATE LOCATION OE \ SCOPE MAINTENANCE EASEMENT D.B. 670 PG. 0275 \-o 1 gyp' v_ �S- LANDS N/F CHARLOTTESI//LLE ALBEMARLE \ RENTAL PROPERT/ES LLC 09. 5040 PG 206 A 101N- 06100-00-00-120P0 ZONED HC - C01VIAY COMMERC/AL) \ USE: COMMERC/AL �d \�9• ��..� PROP. WALL MOUNTED SITE LIGHT (SEE ARCH)(TMP) 1 ROP. KEYSTONE RETAINING WALL COLOR: PALOMINO (MAX HEIGHT' 01) p� BY OT D ESIRSGNED 60 \ B DELIVERIES .02, a1scaUNt s o - � 7,680t SF s 27 SPACES REQUIRED / \ 32 SPACES PROVIDED 6 \/ INCLUDING 2 ADA o GARAGE '��' EXS�NG bF7YOT DOORS 08/4594 PG 25 /0 SIGN / �f 20" C ' 00, \ \OP OA RAMP s PROP KEYSTONE RETAINING WALL WITH RAILING COLOR PALOMINO (MAX. HEIGHT- TOBE ESIGNED BY OTHERS IRON RODS/ FOUND / 100' HOSE 'Lp PROP. / LANDS N/F / W/LCOHESS LLC, D.B 3682 PG 130 0/N 06100-00-00-120D0 ZONED HC (HIGHWAY COMMERC/AL) USE FUEL STATION \ PH �Y 54W CUT CG-12 kDOT JOINT USE UTILITY E425NENT R.B. 4594 PC 14 0..9. 4935 PG 537 / � A Nb I ET LIGHT TED GG-12 `- 1o G Y' S4W CUT ESSEMENT 2D 10 20 1 20' SIGN TYPE "A" SIGN TYPE "C" SIGN TYPE "B" NO NO NO PARKING PARKING PARKING OR OR OR STANDING STANDING STANDING FIRE LANE FIRE LANE FIRE LANE STANDARD WORDING WITH AN STANDARD WORDING WITH AN STANDARD WORDING WITH NO ARROW AT BOTTOM POINTING TO ARROW AT BOTTOM POINTING TO ARROW. TWO SIGNS, BACK TO THE RIGHT. ONE SIGN MOUNTED THE LEFT. ONE SIGN MOUNTED BACK MOUNTED PERPENDICULAR PARALLEL TO THE LINE OF PARALLEL TO THE LINE OF TO THE LINE OF CURBING OR CURBING OR PAVEMENT EDGE AT CURBING OR PAVEMENT EDGE AT PAVEMENT EDGE. END OF PAINTED AREA. END OF PAINTED AREA. SIGNAGE SPECIFICATIONS 1. METAL CONSTRUCTION, 12"x18". 2. RED LETTERS ON REFLECTIVE WHITE BACKGROUND WITH 3/8" RED TRIM STRIP AROUND ENTIRE OUTER EDGE OF SIGN. 3. LETTERING ON SIGN TO BE: "NO PARKING OR STANDING FIRE LANE". 4. LETTERING SIZE TO BE AS FOLLOWS: A. NO PARKING AND STANDING -2". B. OR -1 C. FIRE LANE-2112". D. ARROWS VXV SOLID SHAFT WITH SOLID HEAD 1 1/2" WIDE AND 2" DEEP. 5. SIGNS ARE TO BE MOUNTED 6' FROM GROUND SURFACE TO THE BOTTOM OF THE SIGN UNLESS OTHERWISE DIRECTED BY THE FIRE OFFICIAL. 6. POSTS FOR SIGNS, WHEN REQUIRED, SHALL BE METAL AND SECURELY MOUNTED, UNLESS WRITTEN PERMISSION FOR ALTERNATIVES IS OBTAINED FROM THE FIRE OFFICIAL PRIOR TO INSTALLATION. SIGNS SHOULD BE SPACED AS REQUIRED BY REGULATIONS ABOVE AND AS SHOWN ON THE APPROVED SITE PLAN. 7. OTHER SPECIAL SIGNS MAY BE ALLOWED IF APPROVED IN ADVANCE BY THE FIRE OFFICIAL. FIRE LANE SIGNAGE NOT TO SCALE NOTES: 1. A KNOX BOX WILL BE REQUIRED AND LOCATION COORDINATED WITH THE FIRE MARSHAL OFFICE. 2. SMOKING SHALL BE PROHIBITED IN AREAS WHERE SMOKING MAKES CONDITIONS SUCH AS TO MAKE SMOKING A HAZARD AND THESE AREAS SHALL BE DESIGNATED WITH NO SMOKING SIGNS PER VIRGINIA STATEWIDE FIRE PREVENTION CODE. 3. AREAS WHERE SMOKING CAN OCCUR, SHALL HAVE APPROPRIATE RECEPTACLES FOR DISCARDED SMOKING MATERIALS PER VIRGINIA STATEWIDE FIRE PREVENTION CODE. 4. PER THE VIRGINIA STATEWIDE FIRE PREVENTION CODE, VEHICULAR ACCESS FOR FIREFIGHTING SHALL BE PROVIDED AT ALL CONSTRUCTION AND DEMOLITION SITES, PROVIDE ACCESS TO WITHIN 100 FT OF TEMPORARY OR PERMANENT FIRE DEPARTMENT CONNECTIONS, AND HAVE NO OVERHEAD WIRING OR OTHER OVERHEAE OBSTRUCTIONS LOWER THAN 13 FT 6 INCHES: THIS ACCESS MAY BE VIA 5. CONTRACTOR SHALL ENSURE THE STREET NUMBERS ARE ALWAYS PLAINLY VISIBLE FROM THE FRONTAGE STREET DURING CONSTRUCTION PER THE VIRGINIA STATEWIDE FIRE CODE. 6. AN APPROVED WATER SUPPLY FOR FIREFIGHTING OPERATIONS SHALL BE IN PLACE AVAILABLE AS SOON AS COMBUSTIBLE MATERIALS ARRIVE ON SITE. 7. WASTE AND COMBUSTIBLE DEBRIS SHALL BE REMOVED FROM THE BUILDING AT THE END OF EACH DAY AND DISPOSED OF IN ACCORDANCE WITH THE VIRGINIA STATEWIDE FIRE CODE. 8. FIRE EXTINGUISHERS SHALL BE PROVIDED, WITH NOT LESS THAN ONE APPROVED FIRE EXTINGUISHER AT EACH STAIRWELL, ON ALL FLOOR LEVELS WHERE COMBUSTIBLE MATERIALS HAVE ACCUMULATED, IN EVERY STORAGE AND CONSTRUCTION SHED AND IN AREAS OF SPECIAL HAZARDS, SUCH AS WHERE FLAMMABLE AND COMBUSTIBLE LIQUIDS ARE STORED OR USED, IN ACCORDANCE WITH THE VIRGINIA STATEWIDE FIRE CODE. 9. OPERATIONS INVOLVING THE USE OF CUTTING AND WELDING SHALL COMPLY WITH THE VIRGINIA STATEWIDE FIRE PREVENTION CODE AND SHALL REQUIRE A PERMIT FROM THE ALBEMARLE COUNTY FIRE MARSHAL'S OFFICE. LEGEND PAINTED YELLOW CURB TO DESIGNATE FIRE LANE UNPAINTED CURB OA FIRE LANE SIGN TYPE "A" OFIRE LANE SIGN TYPE "B" OFIRE LANE SIGN TYPE "C" LEGEND ........— PROPSAWCUT —LOW—LOW— LIMIT OF WORK LOD LOD LIMIT OF DISTURBANCE O z w w LU rn WZ F W0of LU Ix z �w (O ZLLU WU) jW ~wax wz mej-j>zUWW0 ai DM<<z< zcnMwzp: - mzof< 0 Q J Ofz < z D_ D_ J of O O W H REVISIONS DI REV DATE COMMENT 1 10/29/2021 PER ISP COMMENTS 2 01/21/2022 PER COUNTY COMMENTS 3 04/08/2022 PER COUNTY COMMENTS • Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: SITE -2 PROJECT SITE PLAN DOCUMENTS FOR o1scBUNT PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLER// 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@BohlerEng.com rF_ALTH e� Lic. No. 0402056625 04/08/2022 SHEET TITLE: FIRELANE PLAN SHEET NUMBER: C-303 REVISION 3 - 04/08/2022 U-� LANDS N/F MPB, INC. D.B 5476 PG 471 PIN 06100-00-00-12000 ZONED.• HC (H/GHI�UAY COMMERC/AL) USE WAREHOUSE \ \ \ 3 a u, zz D, z 3 g u, z z U 3 9> 10\ �B• R3 a i ry0h z 3 / LOADING SPACE 237 LANDS NS�F SULLIVAN, W/LL/AM EDl4ARD & ✓OHN A D. F / B 1095 PG. FIN.- 06100-00-00-120W0 ZONED: HC rH/GHINAY COMMERCIAL) USE: COMMERC/AL N ,J917480 h/ a W \ ROP. KEYSTONE RETAINING \ � WALL WITH SAFETY RAILING COLOR: PALOMINO (MAX. HEIGHT: 4') TO BE DESIGNED BY OTHERS \ PROP TRASH ENCLOSURE APPROX/MATE LOCATION OE \ (SEE ARCH) SCOPE MAINTENANCE EASEMENT D.B. 670 PG. 0275 \ v o LANDS N/F CHARLOTTESV/LLE ALBEMARLE \ RENTAL PROPFRT/ES LLC D.B 5040 PG 206 \ PIN- 06100-00-00-120RO ZONED HC - C01V1AY COMMERC/AL) \ USE: COMMERC/AL GM \ 95' • \ ROP. KEYSTONE RETAINING WALL COLOR: PALOMINO \ (MAX HEIGHT:0.9') \ op6 BY ESIOTHBE DERSGNED 0 \ ROP. SITE AREA = 1.32 AC (R)1.314 (M) \ DELIVERIES \ a1staUNt � � A 7,680t SF s 27 SPACES REQUIRED / \ 32 SPACES PROVIDED IN CLUDING 2 ADA o GARAGE '��' EXS�NG UF7E5EME T DOORS 08/4594 PG 25 \ ° �CONC -A \ / STAIRS OP. DA RAMP LANDS /V/F S S C ACQUISITIONS INC. D B 1429 PG 330 ,PIN.- 06100-00-00-120D7 ZONED: HC (HIGHWAY COMMERC/AL) USE. SELF STORAGE PROP. KEYSTONE RETAINING WALL WITH RAILING COLOR: PALOMINO (MAX. HEIGHT: 4.8') TO BE DESIGNED BY OTHERS PROP. SITE AREA =1.32AC, (R)1.314 (M) W / N 9917129 LANDS N/F / hY/LCOHESS LLC, D.B 3682 PG 130 P/N 06100-00-00-12000 ZONED HC (HIGHWAY COMMERC/AL) USE FUEL STAT/ON JOINT USE Y EASEMENT 4594 PC 14 A935 PG 537 S4W CUT N J917,125 ESSEMENT W 2D 10 20 1 "= 20' WB-67 - Interstate Semi -Trailer Overall Lenggth 73.501ft Overall Wid81 8.500ft Overall Body Height 13.500ft Min Body Ground Clearance 1.3341t Max Track Width 8.500ft Lock -to -lock time 6.00s Max Steering Angle (Virtual) 28.40° VEHICLE DIAGRAM N.T.S. LEGEND —..--•--.— PROP SAWCUT LOW LOW— LIMIT OF WORK LOD LOD LIMIT OF DISTURBANCE O z EE w w w rn z —WW w z Wp0zw5 Z W W � > W z>-0— of FwQ= wz -j>ZUwtn0 U) 7 2 of Q Q Z Q Zcn2wZF1-- 0 zQa~O CIL z J 00 W Z z aQ a-J of U w 1— tn REVISIONS REV DATE COMMENT 1 10/29/2021 PER ISP COMMENTS 2 01/21/2022 PER COUNTY COMMENTS JB 3 04/OS/2022 PER COUNTY COMMENTS • Know what's below. call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DISH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: SITE -2 PROJECT SITE PLAN DOCUMENTS FOR DISCUUNt PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLER// I 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@BohlerEng.com rF_ALTH e� Lic. No. 0402056625 04/08/2022 SHEET TITLE: TRUCK MOVEMENT PLAN SHEET NUMBER C-304 REVISION 3 - 04/08/2022 3 a z z K I LANDS N/F � ,----------------- \ SULL/VAN, WED W ARD & ✓OHN A F D.B.8. 1 / 095 PG. 237 P/N.- 06700-00-00-120WO \ / ZONED., HC rH/GHWAY COMMERC/ALA X// USE COMMERC/AL , A)`,,3917,490 N `�ANDS Nlf = '/ - - - - - MPB, INC./ °�/oo�/goo `� ,' - - D.B. �15476 PG. 471 P/N: 06100-00-00-12000 � /,'' TW/BW 509.00 E \ `\ZONED. HC (H/GHWAY COMMERC/ALJ aj USE' `kYAREHOUSE / TC 506.00 \ RaP. KEYSTONE RETAINING ) y �, TC 505.50 RAILING i z z ,� , WALL WITH SAFETY RAIL 7 ' o a '� COLOR: PALOMINO (MAX. -- 50 �1'; /HEIGHT: 4')TO BE DESIGNED -------__ i ♦0 BY OTHERS TW 509.00 TC 505.20 / - TC 505.00 BW 505.00 --- . -- / ----__ / TC504.85 ---------- \ TC 503.95 \--------- I ' --- 0 TC 50380 Smarr_ / -------- Y / I♦ -vim W5050j ♦♦ - ____ I - -- --- -- ----- - 7 - �E E F ♦ REB4R '� '/ TC502.55 \ --- CH/4RL 0 SI// �' ♦ FOUND l/ o •`\ '' 0-------- - xsaz�r ', \' RENTAL PROPERT/ES LLC So9 Tcsas.00 _ _ _, \ h� D.B. 5040 PG 206 ( rc so2.o6 \s ZONED - - - / o� . 06 -' 00 00 120 N HC_H/�HdYAY COMMERC/AL� TC 501.35 ll.S MMERLYAL TC 500.35 GM'\ ♦ v ,v QO TC 504.95 / T' tiST A ST / A I I 1'v`v ° I '♦ A-80 TC5W80 1 1 ' ' RIM 500.00-- /� TC 505.50 / � �/ ' ^h' � � " Y\ I , , Dm.. G 500.85 � ♦ G50020 \� G! A KNG EYSTONE ' ' \ �"'->• ' RIM 500.00 / RETETAINIWALL - COLOR' PALOMINO 500.80 (MAX HEIGHT: 0.9' ♦ _ `\ o� �•. ,l /'' i /' l i / TO BE DESIGNED ----- \ BY OTHERS \\ \ \ / \ 1 - \ TC 502.45 TC 501 90 / G�0.20TC 500.80__- \ ROP. SITE AREA = 1.32 AC (R)1.314 (M) ♦ \ - o STM A-60 TC 503.15/ / TC/G 500.85 j G500.85��� \ v. IM 560.50 0 I \ / >, G 500.65 TC 500.75 \, \ ♦ \ TC 502.10 G 500 65 \ DIS 0 - _ ` MEIG 510.50± V� solar- \ \ � C LINt s G 500.85 - n „ TW 198.60 , \CURB INLET TC 503 05 ` TC50075 BW49770 � RIM=50293 \ \1 \ \ \ \ \ 1 \ 1 , , 1, II I1 I , I 1 I I , I I , 1 , II I , I II II , I I I I ' I ' I \ \ 11 11 I 1 , 1 1 1 \ G 502.05 - e G 500.85 RIM 500.45 \ / \ T1'Y W8.65 )`. G 500.65 TC 500.75 STM � '` \ �res92.eo FIFE 500.85 G 501.80 - G 500.85 TC 498.90 \` \ . \z `. DD� \� � '�•�\� `•,., TC 500.75 TC 498.70 \ \ i 20 502.50 RIM 500.45 _980 G500.85 49 TC 50070 ' / TC 50750 STM o 502 80� TC \< ' G 500.70 4 �+�s9 7E�.2rzsa 99 ', . •� 'RCP c.xazz4 TC500.85 TC499.80 G500.35 / \ STM SEE L-MO N0 � TC 500.75 \ SUENYX 502.50 - / TC 497.40 / QEY.=5Gi2iY1 o J i.'� f _ RIM 494.75 , h I \ •~ G 500 85 . -. TCIG 500.25 A PROP KEYSTONE _ _ TC 500.75 TC 498.50 _ I I \`l STM �+. / _ v'�0 `g RIM=,Svo. �� G 500.85 d. B-10 Q / RETAINING WALL \ p +. - / ` S LANDS NSF 1 WITH RAILING \ �j ` • TC 500 75 J CIO S S C ACOV5171ONS INC. COLOR: PALOMINO G 500.35 TC 9.95 497.75L/TARP MANNOLE DB 7429`vPG 33(R (MAX. HEIGHT:4.8')G49/ ` G4l6 NO CfS',2 \ TO BE DESIGNED TW 504.00 G500.15 ' TC497.95 R/M=49459� PIN 05100-00-00-120Q7 BY OTHERS O� ` ", TCIG 500.45 TC 500.60 v p9 `ZONED: HC HIGHWAY COMMEI�YAL - ew5oz.00 v w r CURB /NLL7 / /NV 490 00 USE. SELRIY F STORAGE �;`� V`?o.' /SEE DEPC NOTE 4� oU \ g ,. Dq yam, TC 500.45 ,` TC 499.20 G 498.90 s MEIG 499.02SAk' CUT � ` TC 500.50 / o TCIG 498.80 \ ll, TC499.15 �,a9e HP/TC 499.25 0 TC 498.85 / 1 IRON RODS/ � �' � ` TC 500 5AJO FOUND `` / / / / RIM 499.70 STM = TC 498.50 TC/G 497 80 / TC 498.75 STM TC 49815- / / / _ / TC/G 497.75 9_ -¢9 PROP. SITE AREA=1.32A TC 498.907y` (R)1.314 (M) �O4 �`: :a ----------------------- --� X ----------------------------------------- TW Op7\ f5�( 499.75 ai ------------ _ \ ;' o -- ---- LANDS'`. 4g1' o / -------- --= !N/LCOHESS ELEr P/1C�06100 00-00-120D0 - _ZONED HC� 0HWAY Z'QMMERC'ALf ; / / / -- USE. FL n, STAT16 ; ----------- /----------- - - -- -----, TC 497.70� / y A MEIG497.00± ' _- Y ,v 49J, ME/G 493.95+ N ' / �X/fP fP,K91, m.4 G 496.00 51 p S' N 3,917,125 GRADING LEGEND EX/ST/NGNOTE TYPICAL NOTE TEXT PROPOSED NOTE 120 ------------- 125 ------------ CONTOUR LINE 07 .5%5=' SPOT ELEVATIONS C516.00 TC 516.00 BC 515.55 iS N SANITARY LABEL SAN # aTCI STORM LABEL T # STORM SEWER STORM MANHOLE i O` TYPICAL END SECTION HEADWALL OR ENDWALL �OR� FSVj YARD INLET O -, CURB INLET MONITORING WELL BORING ® BENCHMARK TEST PIT ADA CONSTRUCTION NOTES TO CONTRACTOR 2. NO ADA PARKING SPACE IS TO EXCEED 2.00% SLOPE IN ANY DIRECTION. 3. NO ADA CURB RAMP IS TO EXCEED 8.33%. 4. THE CONTRACTOR IS RESPONSIBLE DURING THE FORMING OF SIDEWALKS, RAMPS, CROSSWALKS, AND ADA PARKING TO VERIFY THAT ADA COMPLIANCE IS ACHIEVED. PROPOSED ADA AREA TO BE CONSTRUCTED WITH STRIPING ONLY, AS EXISTING GRADES BELIEVED TO BE ADEQUATE. CONTRACTOR TO CHECK EXISTING CONDITIONS. 5. IF DURING THAT CHECK ANY NON-CONFORMANCE IS DETERMINED, THE ENGINEER IS TO BE IMMEDIATELY NOTIFIED PRIOR TO POURING CONCRETE AND/OR LAYING ASPHALT. / ME/G 495.00±- b LEGEND S� /--.--.--.- PROP SAWCUT \ o leE0AN� Qi ---LOW-LOW` LIMIT OF WORK �Q LOD LOD LIMIT OF DISTURBANCE 0± 54Y CUT \ 20 10 5 0 20 ✓ P5Q ` \ 11120' LU z Ir W W 19 W F W WzWWU)� I--j! a <xzvU)Qz MJ z U) 0zW< z 000 J W coU1 of3-z�a J O O W H U7 REVISIONS REV DATE COMMENT 1 10/29/2021 PER ISP COMMENTS 2 01/21/2022 PER COUNTY COMMENTS 3 04/08/2022 PER COUNTY COMMENTS Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: GRAD -2 PROJECT: SITE PLAN DOCUMENTS FOR DISt®C lnu PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@BohlerEng.com rF_ALTH e21 Lic. No. 0402056625 6, 04/08/2022 j SHEET TITLE: GRADING PLAN SHEET NUMBER: C-401 REVISION 3 - 04/08/2022 N n O 3 A 0 J 5 N 3 a N z N W z 3 a z z 0 U /� LANDS N/F MPS, INC. D.S. 5476 PG. 471 P/N- 06100-00-00-12000 VV E ZONED.- HC (HICHWAY COMMERC/AL) USE.' WAREHOUSE W N O D m 'o \ N S + 000 \ D� ` 7RE84R OF / LANDS N F SULL/VAN, W/LL/AM EDD & ✓OHN A F / D.B. 10-0 - -12 P/N.' 06100-00-00-1201YO ZONED. HCIH/GHWAY COMMERC/ALA / US : COMMERC/AL , D N $917480 / '� h A ROP. KEYSTONE RETAINING \ \ WALL WITH SAFETY RAILING ROOF DRAIN SCHEDULE Pipe Invert Elev. Length (ft) Slope (%) Dia. (in) Material Upper (ft) Lower R RD-1 497.85 497.76 8.53 1.06% 6 PVC RD-2 497.76 497.33 42.20 1.02% 6 PVC RD-3 497.85 497.75 9.69 1.03% 6 PVC RD-4 497.75 497.35 39.13 1.02% 6 PVC RD-5 497.35 497.23 11.28 1.06% 8 PVC COLOR: PALOMINO (MAX. HEIGHT: 4') TO BE DESIGNED BY OTHERS SANITARY SCHEDULE APPROXIMATE LOCATION OF \ SLOPE MAINTENANCE EASEMENT D.B. 670 PG. 0275 STRUCTURE STRUCTURE UPPER LOWER PIPE PIPE PERCENT NUMBER (SAN) TYPE INVERT INVERT LENGTH (FEET) SIZE/ TYPE SLOPE BLDG - CO-3 CLEANOUT 497.85 497.25 13.08 4" PVC 4.59% CO-3 - CO-2 CLEANOUT 497.25 492.58 101.05 4" PVC 4.62% CO-2 - CO-1 CLEANOUT 492.58 1 491.92 14.11 4" PVC 4.68% CO-1 - EXCO CLEANOUT 491.92 491.59 7.41 4" PVC 4.45% LANDS N F \ CHARLOTTESV/LLE ALBEMARLE RENTAL PROPERTIES LLC D.B. 5040 PG. 206 ` PIN- 06100-00-00-120PO ` ZONED.' HMAY COMMERC/ALA US 5C- : COCOMMERC/AL ®GM STM D\ GRATE INLET '~ TM /3� A-70 ROP. KEYSTONE �- • •' RETAINING WALL ROP. 90° COLOR: PALOMINO DLET / BEND (MAX HEIGHT: DESIGNED / GRATE INLET / TO BE DESIGNED � BY OTHERS 0 I STM r. ROP. SITE AREA = 1.32 AC (R) 1.314 (M) ` I � ' A-60 = / • q0 RD-1 1111, PCA DISCO_ UN11 g BENDS 45 oq� CIO sli\ GRATE INLET LANDS N/F S S C ACQUISITIONS INC. D.B. 1429 PG. 330 PIN.- 06100-00-00-120D1 ZONED.• HC (HIGHWAY COMMERCIAL) USE.• SELF STORAGE DOMESTIC WATER SCHEDULE FIXTURE OTY. WSFU TOTAL CW HW WATER CLOSET (FLUSH VALVE) 3 10 30 1" - URINAL (FLUSH VALVE) 2 5 10 34" - LAVATORY 3 2 6 )1" X2" MOP BASIN 1 3 3 X2" V LAUNDRY TUB 1 3 3 h.h. WATER COOLER 2 0.25 0.50 Y20 - HOSE BIBB 1 3.0 3 3'4"WSFU - TOTAL 55.50 (50 GPM MAX) 'ALL DETAILS ON THIS SHEET (OR WITHIN THIS FRAME) WERE PROVIDED BY DIALECTIC) AND AR -OR INFORMATIONAL PURPOSES, ONLY. BOHLER SHALL BE HELD HARMLESS IN THE EVENT OF =RRONEOUS INFORMATION CONTAINED WITHIN THESE DETAILS AND/OR STRUCTURAL FAILURE GRATE oo, Bl oy PROP. 2" WATER O01 SERVICE LINE `.. PROP. KEYSTONE RETAINING WALL \ WITH RAILING COLOR: PALOMINO (MAX. HEIGHT: 4.8') TO BE DESIGNED BY OTHERS , , , , , h h i \J • / RD-2 APPROX/ TE LOCATION OF EXIST/NTIL/7Y EASEMENT / RD-5 \6 08/4594 PG 25 /O SIGN / RD-0F° \f 20 SN SIM w A.40 RD-3 00, ' / \ P `I'l UPDI�3B - L=6' 4 1�1"A RCP CURB INLET i 7 CC S \/ PROP. B" ,f ✓n s! B O0 ROP. 15' CP STO � FIRE LINESAI �Q �' cSNO STM �0 ..�� 6 RIV Juo. ` Sop •,'.'..': / ; clo T �4f • / O�tr / CID o3 y .. / / a b c o / l \O \ STM L C PROP. 2" WATER METER pp PROP. TEE PROR HYDRANT p ��s ♦ C LANDS NIF / W/LCOHESS LLC, r� D.S 3692 PG 130 PIN.- 05100-00-00-120D0 ZONED HC (HIGHWAY COMMERC/AL) N07 USE.FUEL STATION UP N011,\ _oy off -oN� -�H OH \ / FDC STM / C-20 PROP. 11.25° BEND / DI-3B - 1-=6' CURB INLET i, �:�`VOOT JOINT USE UR(/TY EASEMENT DB 4594 PC 14 0..9. 4935 PG 537 A-10 O Vy0 G�� �N O 1N/TARY MANHOLE V-04.51 SAW CUT g �YY G �e Pye / SANITARY MANHOLE NO ACCESS RLM=49459 FE DEMO NOTE 4) SAW CUT N J917,125 ESSEMENT W 20 10 5 0 20 1 "= 20' UTILITY LEGEND EXISTING NOTE TYPICAL NOTE TEXT PROPOSED NOTE SA N SANITARY SAN ILI LABEL # 4STORM e LABEL SL SANITARY SEWER eL LATERAL yy UNDERGROUND W WATER LINE E UNDERGROUND E ELECTRIC LINE G UNDERGROUND G GAS LINE -OH OVERHEAD OH WIRE T UNDERGROUND T TELEPHONE LINE G UNDERGROUND C CABLE LINE - - - - - - - - - - STORM - SEWER S SANITARY S SEWER MAIN HYDRANT O SANITARY O MANHOLE 0 STORM i O` MANHOLE WM ® WATER METER WV x WATER • VALVE El GAS El VALVE ® GAS METER TYPICAL END SECTION 0� HEADWALL OR ENDWALL O YARD O INLET CURB INLET O CLEAN O OUT O ELECTRIC O MANHOLE O TELEPHONE O MANHOLE EB ELECTRIC EB BOX ELECTRIC EP PEDESTAL ® MONITORING WELL TEST YY PIT UTILITY NOTES: 1. PROPOSED BUILDING IS NOT SPRINKLERED. 2. STORM WITHIN PROPOSED EASEMENT TO BE PRIVATELY MAINTAINED. 3. EX. CLEAN OUT LOWER INVERT OF 491.59 IS ASSUMED AND CONTRACTOR WILL NEED TO VERIFY THAT THE INVERT WORKS. IF EXISTING INVERT IS HIGHER THEN CONTRACTOR CAN DECREASE SLOPE UP TO 2.08%. SUBMIT ANY CHANGES OR DISCREPENCIES TO BOHLER ENGINEERING IN WRITING. 4. REQUIRED FIRE FLOW FOR THE BUILDING IS 1,000 GPM. TEST PIT NOTE: 1. CONTRACTOR TO TEST PIT 2 FEET BELOW PROPOSED UTILITY OR UNTIL EXACT LOCATION OF EXISTING UTILITY IS IDENTIFIED AND SUBMIT ANY DISCREPENCIES TO 80HLER ENGINEERING IN WRITING. LEGEND -----•---- PROP SAWCUT -LOW-LOW- LIMIT OF WORK LOD LOD LIMIT OF DISTURBANCE 0 z EE W W W U) Z W H W wwjw n(DZU) z 5: CD 1= WWO FWa wz -j>zUWrn0 U) 7 M Q Q Z Q zcnMWz_FH- zZof aaa~Of O z J 00 COW z z aQ a J of U W H REVISIONS REV DATE COMMENT DRAwx er CHECI(ED BY 1 10/29/2021 PER ISP COMMENTS DSH RTY 2 01/21/2022 PER COUNTY COMMENTS BSC RTY 3 04/OS/2022 PER COUNTY COMMENTS BSC RTY • Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DISH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: GRAD -2 PROJECT SITE PLAN DOCUMENTS FOR DISC®C�7aQ PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLER// I 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@BohlerEng.com rF_ALTH e21 Lic. No. 0402056625 04/08/2022 SHEET TITLE: UTILITY PLAN SHEET NUMBER: C-501 REVISION 3 - 04/08/2022 498 N z z 3 w w J z N w z 3 a N z z 3 9 a U NerUing=3917115.9129 ' Easting=11490074.6943 510 500 490 T P OR GRADE I PROP.8" DIP WATER MAIN � =O� W f LU FW W W ��? XLJ m m 4 m c v s> _ > �O � �OO m��0ao �<o �a�?�a�a 10+00 10+50 11+00 PROPOSED WATER PROF/LE SCALE: 1"=50' HORIZONTAL 1 "= 5' VERTICAL 510 500 490 510 500 490 20 10 5 0 20 1"= 20' STM STM A STM STM A-40 A-50 \ A$0 STM STM A-30 / \\ A-70 A-80 PROP. GRAD / \ r 1 ' 3 1711- 10Y HGL 39.99- 1 RCP 15-RCP 30 O'- 15" RCP 560A @ 0.54% 15 RCP @ 0.50% @ .50% 80.00'-48"CMP @ 0.00% 0 0 t? h t0 V N N U 19 In c U azn W W v .-. .-. V W W (� ry LU W 0.v mom 0cmi o Uc o aaZp ad 2 zp ro a�Z v auiZp a�Zp� o ate c a ???? ¢ a? ?a 2� 10+00 10+50 11+00 11+50 12+00 12+50 PROPOSED STNPROFILE A 30 TO SCALE: 1"= 50' HORIZONTAL 1"= V VERTICAL 510 WATERLINE PROFILE NOTE: 1. CONTRACTOR TO TEST PIT AND DETERMINE IF WATERLINE VERTICAL RELOCATION REQUIRED TO AVOID UTILITY CONFLICTS AND CONNECTION. STORM PROFILE NOTES: 1. CONTRACTOR TO VERIFY MANHOLE SIZE PRIOR TO ORDERING STRUCTURES. 500 TEST PIT NOTE.- 1 . CONTRACTOR TO TEST PIT 2 FEET BELOW PROPOSED UTILITY OR UNTIL EXACT LOCATION OF EXISTING UTILITY IS IDENTIFIED AND SUBMIT ANY DISCREPENCIES TO BOHLER ENGINEERING IN WRITING. 490 z EE w w w rn z FW w z W��w� 0 UWrnojW I.- h Fwa= wzm >Z0LU0 20;aQzQ Ozcn<wzFOf za<a 0 Qof J O D� W z z as a > J of U w H REVISIONS REV i DATE I COMMENT 1 110129120211 PER ISP COMMENTS I ' 2 �01/21/2022 PER COUNTY COMMENTS sc RTY 3 04/OS/2022 PER COUNTY COMMENTS BSc RTY ia Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: PUTL-2 PROJECT: SITE PLAN DOCUMENTS FOR DISICUMQ PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@BohlerEng.com TH Lic. No. 0402056625 04/08/2022 SHEET TITLE: UTILITY PROFILES SHEET NUMBER: 50 25 12.5 0 50 C r 0 2 1 "= 50' REVISION 3 - 04/08/2022 500 490 T T STM -20 PR P. GRADE 8 .00' - 48" CMP @ 0.005 10 YR HGL Q u Q V R u Q S av omoW �C�°jhe r 10a00 10+50 11+00 500 500 490 490 PROPOSED STNPROF/LE(A-W TOA 20) SCALE: 1 "= 50' HORIZONTAL 1"= 5' VERTICAL N z z 3 w w u, J z N w z 3 a N z z 3 9 a U STM B-20 STM B-10 PROR GRADE 15.90' - 15"RCP EX GRA @ 0.57% 10 YR HGL � F o S N o U rn Z a U m 0 a o a K 2> + m p , �> 10,00 10+50 500 500 490 490 PROPOSED STMPROFILE /B-10 TO 520 SCALE: 1%50' HORIZONTAL 1 "= V VERTICAL STM C-10 PROP .G D STM ' AOE 7EX 62.20'-1V RCP @0 % 10 YR HGL 0 F- o_ 0 m Z m a Z Um0 a o o a �> N o a > > =Z W 10,00 10a50 11+00 PROPOSED STNPROF/LEX--10 TO C SCALE: 1'= 50' HORIZONTAL 1 "= V VERTICAL STORM PROFILE NOTE: 1. CONTRACTOR TO VERIFY MANHOLE SIZE PRIOR TO ORDERING STRUCTURES. 500 TEST PIT NOTE: mej 1. CONTRACTOR TO TEST PIT 2 FEET BELOW PROPOSED UTILITY OR UNTIL EXACT LOCATION OF EXISTING UTILITY IS IDENTIFIED AND SUBMIT ANY DISCREPENCIES TO BOHLER ENGINEERING IN WRITING. O 490 50 25 12.5 50 1"= 50' z w W W 10 Z F W Z W H O W Ur z W W W j w z7-(9t=Wp0'() Fw<= wz J>z0UJWO Q 7 of Q Q Z Q zU) W zFH- uzaaa~O Q J D� Of W z z aQ J aQ of J F U w H REVISIONS REV i DATE I COMMENT 1 110129120211 PER ISP COMMENTS I ' 2 I01/21/2022I PER COUNTY COMMENTS RTY 3 04/08/2022 PER COUNTY COMMENTS BSC RTY • Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: PUTL-2 PROJECT: SITE PLAN DOCUMENTS FOR DIStUMU PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@BohlerEng.com TH Lic. No. 0402056625 04/08/2022 SHEET TITLE: UTILITY PROFILES SHEET NUMBER: C-503 REVISION 3 - 04/08/2022 N z 3 w u, zz N z 3 a N z z 3 9 a U 10 YEAR STORM COMPUTATIONS From Point To Point Drain. Area (acres) Runoff Coeff. C CA Inlet Time (min) Rainfall Intensity (in/hr) Q Invert Elev. Length (ft) Slope (%) Dia. (in) n Capacity (cfs) Velocity (fps) Flow Time QI Qfull VI Vfull Vfull Remarks Incr. E Incr. (cfs) Known (cfs) F (cfs) Upper (ft) Lower (ft) Incr. (min) E (min) A-80 A-70 0.20 0.90 0.18 0.18 5.00 6.64 1.20 - 1.20 497.00 496.85 30.00 0.50% 15 0.013 4.58 3.10 0.16 5.16 0.26 0.83 3.73 A-70 A-60 0.24 0.90 0.22 0.40 5.16 6.60 1.45 - 2.64 496.65 496.45 37.37 0.54% 15 0.013 4.74 3.92 0.16 5.32 0.56 1.02 3.86 A-60 A-50 - - - 0.40 5.32 6.55 - - 2.62 496.25 496.05 35.58 0.56% 15 0.013 4.86 4.02 0.15 5.47 0.54 1.02 3.96 A-50 A-40 0.05 0.90 0.05 0.45 5.47 6.51 0.33 - 2.94 495.85 495.65 39.99 0.50% 15 0.013 4.58 3.96 0.17 5.64 0.64 1.06 3.73 A-40 A-30 0.05 0.90 0.05 0.50 5.64 6.47 0.32 1.07 4.30 495.45 494.95 88.69 0.56% 15 0.013 4.86 4.46 0.33 5.97 0.88 1.13 3.96 A-20 A-10 - - - - - - - 8.20 8.20 490.80 490.00 74.03 1.08% 24 0.013 23.58 6.77 0.18 5.18 0.35 0.90 7.51 EX. INV OUT 489.35 B-20 B-10 0.22 0.90 0.20 0.20 5.00 6.64 1.33 - 1.33 492.29 492.20 15.90 0.57% 15 0.013 4.87 3.30 0.08 5.08 0.27 0.83 3.97 B-10 EX-3 0.24 0.51 0.12 0.32 5.08 6.62 0.79 - 2.11 492.00 490.00 24.00 8.33% 12 0.013 10.31 10.19 0.04 5.12 0.20 0.78 13.13 C-20 C-10 0.22 0.90 0.20 0.20 5.00 6.64 1.33 - 1.33 491.25 490.90 62.20 0.56% 15 0.013 4.86 3.29 0.32 5.32 0.27 0.83 3.96 10 YEAR HGL COMPUTATIONS Structure No. Outlet WSE Do (in) Go Lo Sfo (%) Hf JUNCTION LOSS Final H Inlet WSE Top 1 Throat Elev. Inlet Shaping Pre -Cast Structure Junction Loss Reduction Remarks re- Vo Ho Qi Vi Qi • Vi ViA2I2g Hi Angle K Hd Ht 1.3 Ht 0.5 Ht A-80 497.85 15 1.20 30.00 0.03% 0.01 3.10 0.04 0.04 0.05 0.02 0.03 497.88 500.00 Yes Yes Yes A-70 497.45 15 2.64 37.37 0.17% 0.06 3.92 0.06 1.20 3.10 3.72 0.15 0.05 - - 0.00 0.11 0.15 0.07 0.14 497.59 500.00 Yes Yes Yes A-60 497.05 15 2.62 35.58 0.16% 0.06 4.02 0.06 2.64 3.92 10.36 0.24 0.08 90 0.70 0.17 0.31 - 0.16 0.22 497.27 500.50 Yes Yes Yes A-50 496.65 15 2.94 39.99 0.21% 0.08 3.96 0.06 2.62 4.02 10.53 0.25 0.09 - - 0.00 0.15 - 0.07 0.16 496.81 500.45 Yes Yes Yes A-40 495.95 15 4.30 88.69 0.44% 0.39 4.46 0.08 1 2.94 3.96 11.63 1 0.24 0.09 - - 0.00 0.16 - 0.08 0.47 496.42 500.45 Yes Yes Yes A-20 494.09 24 8.20 74.03 0.13% 0.10 6.77 0.18 0.18 - 0.09 0.19 494.28 498.82 Yes Yes Yes B-20 493.20 15 1.33 15.90 0.04% 0.01 3.30 0.04 0.04 0.05 0.03 0.03 493.23 496.90 Yes Yes Yes B-10 490.80 12 2.11 24.00 0.35% 1.20 10.19 0.40 1.33 3.30 4.38 0.17 0.06 - - 0.00 0.46 0.60 0.30 1.50 492.30 494.75 Yes Yes Yes C-20 491.90 15 1.33 62.20 0.04% 0.03 3.29 0.04 0.04 0.05 0.03 0.05 491.95 494.75 Yes Yes Yes 10 YEAR INLET COMPUTATIONS Inlet DA C I Q Qb Qt S Sx n T W SW On Grade Inlets Only Sag Inlets Only Remarks No. Type Length (ft) Drain Area (acres) Runoff Coeff- icient Inten sity (inlhr) Incr. Flow (cfs) Carry -over Flow (cfs) Accum. Flow (cfs) Gutter Slope (%) Pvmt Cross Slope N Spread On Grade (ft) Gutter Width (ft) W 1 T Gutter Cross Slope N Sw Sx Eo (App. 9C-8) a (in) S'w =a/ (12W) N Se=Sx +S'w (Eo) (%) Lt,Comp. Length (9C-17) (ft) L,Spec -ified Length (ft) L 1 Lt E Qi Qb Down Qi d h (ft) d 1 h Ts rev3/29 Eff. (9C-18) Int'x Flow (cfs) Byp. Flow (cfs) Stream Int'x Flow (cfs) Depth 00 Spread In Sag 00 Str. B-20 Curb DI-3B 6.00 0.22 0.90 6.64 1.31 0.00 1.31 5.00 0.02 0.00 0.00 8.33 1.00 0.00 0.00 0.00 1.31 0.21 0.46 0.46 4.17 In Sag C-20 Curb DI-313 6.00 0.22 0.90 6.64 1.31 0.00 1.31 5.00 0.02 0.00 0.00 8.33 1.00 0.00 0.00 0.00 1.31 0.21 0.46 0.46 4.17 In Sag 10 YEAR HEADWATER COMPUTATIONS Structure DA Drainage Area (ac) C Runoff Coefficient 1 Intensity (inlhr) Q 10 Yr Flow (cfs) Head Water (ft) Rim I Invert Elevation (ft) 10 Yr WSE (ft) Remarks No. Type A-80 Grate DMA 0.20 0.90 6.64 1.20 0.11 Rim 500.00 500.11 A-70 Grate DI -IA 0.24 0.90 6.64 1.43 0.11 Rim 500.00 500.11 A-50 Grate DI-lA 0.05 0.90 6.64 0.30 0.06 Rim 500.45 500.51 A40 Grate DI-1A 0.05 0.90 6.64 0.30 0.05 Rim 500.45 500.50 B-10 Grate DI -IA 0.24 0.51 6.64 0.81 0.14 Rim 494.75 494.89 50% Clogged mi x O Im z af w w w m z Faf w Z W H 0 W 0 z W W W womo-j W zrC9l=oafm Fw<= wZ J> Z O W W O r=n D Q Q z Q zU) Wz_F� uzw<aMO z J 0� W Z Z (LQ J o Q Of J F 0 W H U) REVISIONS REV i DATE I COMMENT 1 110129120211 PER ISP COMMENTS I �01/21/2022 PER COUNTY COMMENTS B RTY I2 3 04/08/2022 PER COUNTY COMMENTS BSC RTY I Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: CNDS-2 PROJECT: SITE PLAN DOCUMENTS FOR DISICUMQ PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@BohlerEng.com TH Lic. No. 0402056625 04/08/2022 SHEET TITLE: UTILITY COMPUTATIONS SHEET NUMBER: C-504 REVISION 3 - 04/08/2022 3 N I j 625 i \ ,SANDS N/F I sss. / \ MPB, INC. D. B. 5476 PG 471 h PIN: 06100-00-00-12000 W E `.ZONED.• //C (N/GHWAY COMMERC/AZ� g USE.• `WAREHOUSE W N z G 7 p it I x N XArQ #29 \•,O� ` Vy RM \ 1 OG \N. , 1 , 11 II I 1 I 11 I , I 1 1 ' 1I II , , I I1, 1 I 1 I I 1 � � I I I , 1 � 1 ' ` S S C ACOU� D.B. 1429' PIN.- 06100-0 ED.- HC (HIGH/ USE. SELF 0 %z oP LANDS N/F SULL/VAN, WILL/AM ED ARD & ✓OHN A F O.B. 1095 PG. 237 PIN.- 06100-00-00-120WO ZONED. HC [HIGHWAY COMMERCIAL) USE: COMMERCIAL , 501 % ` APPROX/MATE 64CAT/0N OF ro �y SLOPE MAINTENANCE EASEMENT ---------''-"---- - ' y 09 670'' PG 0275 / \--------- __-________ \ _ "--507 / 506 s ------------------ - - - - - - - - - - - - - - / --- --- - - -- - - - - - - - - - - - - -- - - - - -- -------------------------------------- - - - - - - - - - - / 5 - p1-- --- - / / ---------------- ------ -- - --= ; W/LCOHESS ECE ---- DBJ682 PG 730 06100-00700-12OD6 / ZONED HC�H(GHWAY-0Y1VfRc /---------- USE• F Eh STAT/dN,, ---- ----------- \ ___________________ LANDSCAPE SCHEDULE KEY QTY. BOTANICAL NAME COMMON NAME CAL. I HT. CONT. 10 YR CANOPY (SF) TOTAL CANOPY (SF) SHADETREES PLO 1 PIATANUSOCCIDENTALIS AMERICAN SYCAMORE 2-21YC CAL. IB-10 BIB 479 479 OF 12 QUERCUS PALUSTRIS PIN OAK 2-2IrZ CAL. IB-10 BIB 471 5,652 SUBTOTAL: 13 SUBTOTAL 6,131 ORNAMENTALTREES LI 1 IAGERSTROEMIA INDICA COMMON CRAPEWRTLE 2-210 CAL.18-10 BIB 77 77 SUBTOTAL: 1 SUBTOTAL: 77 EVERGREEN TREES CDD 4 CRYPTOMERIAJAPONICA JAPANESE CEDAR 8-10'HT. BIB 130 520 IO 5 ILEX OPACA AMERICAN HOLLY 8-10' HT. BIB 56 280 IXN 9 ILEXX'NELLIE R. STEVEN NELLIE R. STEVENS'HOLLY B-ITHT. BIB 44 396 PT 1 PINUS TAEDA LOBLOLLY PINE B-10 HT. BIB 250 250 SUBTOTAL: 19 SUBTOTAL: 1,446 DECIDUOUSSHRUBS CA 21 CLETHRAALNIFOLIA SUMMERSWEEFCLETHRA 18-24' HT. & SPREAD #3 CAN NOTAPPLICABLE DO 16 DEUTZIAGRACILIS SLENDER DEUTZIA 18-24' HT. & SPREAD #SCAN NOTAPPLICABLE IV 47 ITEAVIRGINICA'HENRYS GARNET GARNET$WEETSPIRE 18-2e HT. &SPREAD #SCAN NOT APPLICABLE RAGL 70 RHUS AROMATICA'GRO{OW GR010W SUMAC 18-24' HT. & SPREAD #SCAN NOTAPPLICABLE VD 16 VIBURNUM DENTATUM ARROWWOOD VIBURNUM 18-24' HT. & SPREAD #3 CAN NOTAPPLICABLE SUBTOTAL: 170 EVERGREEN SHRUBS ICBUR 11 ILEX CORNUTA'BURFORDIT BURFORD HOLLY 18-24' HT. & SPREAD #SCAN NOT APPLICABLE ED 27 ILEX CRENAWCOMPACTA' COMPACT JAPANESE HOLLY 18-24' HT. & SPREAD #3 CAN NOTAPPLICABLE IGS 18 ILEXGIABRA'SHAMROCK SHAMROCK INKBERRY HOLLY 18-24' HT. & SPREAD #SCAN NOTAPPLICABLE JCH 15 JUNIPERUS CHINENSIS'HETZII' HETZ JUNIPER 18-24'HT. &SPREAD #3 CAN NOT APPLICABLE RM 29 RHODODENDRON MAXIMUMROSEBAY ROSEBAY RHODODENDRON 18-24'HT. &SPREAD #SCAN NOTAPPLICABLE SUBTOTAL: 100 PERENNIALS LSBS 625 URIOPE SPICATA CREEPINGURIOPE 4 OT NOT APPLICABLE SUBTOTAL 625 ORNAMENTAL GRASSES PVHM 130 PANICUM VIRGATUM'HEAVY METAL' HEAVY METAL SWITCH GRASS 1GAL NOT APPLICABLE SUBTOTAL: 130 LANDSCAPE TRELLIS PLANTING KEY QTY. BOTANICAL NAME COMMONNAME CAL. IHT. CONT. PO 45 PARTHENOCISSUS QUINQUEFOLIA VIRGINIACREEPER 1GALLON MIN \ NOTES \ \ / \ \ \ ALL LANDSCAPING AND SCREENING REQUIRED BY SECTION 32.7.9 SHALL BE INSTALLED AND MAINTAINED AS FOLLOWS: -LIZ \ pp CC A.TIMING OF INSTALLATION. ALL LANDSCAPING SHALL BE INSTALLED BY THE FIRST PLANTING SEASON \ \ FOLLOWING THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY WITHIN THE DEVELOPMENT, OR A PHASE THEREOF. $6 TE _ PPROXI LOCAT/ON OF GL Fi'ST/N� /TY EASEMENT B.MEfHOD OF INSTALLATION. ALL TREES SHALL BE PLANTED IN ACCORDANCE WITH EITHER THE STANDARDIZED /4594��oG: 25 / I / LANDSCAPE SPECIFICATIONS JOINTLYADOPTED BY THE VIRGINIA NURSERYMEN'S ASSOCIATION, THE VIRGINIA SOCIETY OF LANDSCAPE DESIGNERS AND THE VIRGINIA CHAPTER OF THE AMERICAN SOCIETY OF LANDSCAPE ARCHITECTS, OR THE ROAD AND BRIDGE SPECIFICATIONS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION. PLANTING ISLANDS SHALL CONTAIN A MINIMUM OF 50 SQUARE FEET PER TREE, WITH A MINIMUM DIMENSION OF \ FIVE FEET IN ORDER TO PROTECT THE LANDSCAPING AND ALLOW FOR PROPER GROWTH. WHEEL STOPS, -SpO CURBING OR OTHER BARRIERS SHALL BE PROVIDED TO PREVENT DAMAGE TO LANDSCAPING BY VEHICLES. $6 ��. \ / // WHERE NECESSARY, TREES SHALL BE WELLED OR OTHERWISE PROTECTED AGAINST CHANGE OF GRADE. ALL PERVIOUS AREAS OF THE SITE SHALL BE PERMANENTLY PROTECTED FROM SOIL EROSION WITH GRASS OR ICC OTHER GROUND COVER OR MULCH MATERIAL. ��. C.MAINTAINING AND REPLACING LANDSCAPING AND SCREENING. ALL LANDSCAPING AND SCREENING SHALL BE \� MAINTAINED IN A HEALTHY CONDITION BY THE CURRENT OWNER OR A PROPERTY OWNERSASSOCIATION, AND REPLACED WHEN NECESSARY. REPLACEMENT MATERIAL SHALL COMPLY WITH THE APPROVED LANDSCAPE PLAN. D.MAINTAINING TREES IF SITE NOT UNDER SINGLE OWNERSHIP. IN THE CASE OF DEVELOPMENT WITH UNITS FOR SALE, THE TREES SHALL BE MAINTAINED BY A PROPERTY OWNER'S ASSOCIATION. PRIOR TO FINAL SITE PLAN APPROVAL, THE DEVELOPER SHALL SUBMIT TO THE AGENT AN INSTRUMENT ASSURING THE PERPETUAL MAINTENANCE OF THE TREES. THE INSTRUMENT SHALL BE SUBJECT TO REVIEW AND APPROVAL BY THE COUNTY ATTORNEY AND SHALL BE IN A FORM AND STYLE SO THAT IT MAY BE RECORDED IN THE OFFICE OF THE CLERK OF THE CIRCUIT COURT OF THE COUNTY. THE AGENT MAY REQUIRE THAT THE INSTRUMENT BE ON A FORM ' / ,' / , , ��/ PREPARED BY THE COUNTY ATTORNEY. �! E.MAINTAINING STREET TREES PLANTED WITHIN A PUBLIC STREET RIGHT-OF-WAY. IF STREET TREES ARE PLANTED WITHIN THE PUBLIC STREET RIGHT-OF-WAY, THE TREES SHALL BE MAINTAINED IN ACCORDANCE WITH / THE REQUIREMENTS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION. � Soo— ,e- FALL SITE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED TO REACH, AND BE MAINTAINED AT, MATURE HEIGHT; THE TOPPING OF TREES IS PROHIBITED. SHRUBS AND TREES SHALL BE PRUNED MINIMALLY AND ONLY TO SUPPORT THE OVERALL HEALTH OF THE PLANT. / 116 G CA p P 00 APPROXIMATE LOCATION OF / C7, PERMANENT 9RAINACE EASEMENT ` 5P9.9_ ROP.0 2 OB 4594 PG 25 ST 14 -- - PG 537 _ 49� _ V= 20' LEGEND LOW —LOW— LIMIT OF WORK LOD LOD LIMIT OF DISTURBANCE x x x x x x x x x x x x x x x x x x x x x x x CREEPING LIRIOPE x x x x x x x x x x x x PLANTING AREA x x x x x x x x 000 000 6 4k p �° ° ° ° 0 6 4, ° °A HEAVY METAL SWITCHGRASS ° O Z, p zPLANTING p° p p AREA 0 z_ of W W W Tn Z I- of W Wz Wo-ww z W W w 5 W z_r01--LU Wm ~Wax Wz �:i>zUW6n0 mir=n D a Q z Q ZU) WZFH uzw<amo Q J 0 W Z z o- z > o_ J of O O W 1-- REVISIONS REV DATE COMMENT DI 1 10/29/2021 PER ISP COMMENTS 2 01/21/2022 PER COUNTY COMMENTS 3 04/08/2022 PER COUNTY COMMENTS 15 Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: LSCP -2 PROJECT SITE PLAN DOCUMENTS FOR DISCOOM PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLER// 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@,BohlerEng.com NICHOLAS T GEO GAS r. Cert. No. 001653 h 17y0 Q 04/08/2021 5+04 PE A — SHEET TITLE: LANDSCAPE PLAN SHEET NUMBER: C-701 REVISION 3 - 04/08/2022 3 1 "= 40' LEGEND 0 0 NOTES INTERIOR PARKING LOT LANDSCAPE AREA ALL LANDSCAPING AND SCREENING REQUIRED BY SECTION 32.7.9 SHALL BE INSTALLED AND MAINTAINED AS FOLLOWS: INTERIOR PARKING LOT TREE J A.TIMING OF INSTALLATION. ALL LANDSCAPING SHALL BE INSTALLED BY THE FIRST PLANTING SEASON FOLLOWING THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY WITHIN THE DEVELOPMENT, OR A PHASE THEREOF. B.METHOD OF INSTALLATION. ALL TREES SHALL BE PLANTED IN ACCORDANCE WITH EITHER THE STANDARDIZED LANDSCAPE SPECIFICATIONS JOINTLY ADOPTED BY THE VIRGINIA NURSERYMEN'S ASSOCIATION, THE VIRGINIA SOCIETY OF LANDSCAPE DESIGNERS AND THE VIRGINIA CHAPTER OF THE AMERICAN SOCIETY OF LANDSCAPE ARCHITECTS, OR THE ROAD AND BRIDGE SPECIFICATIONS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION. PLANTING ISLANDS SHALL CONTAIN A MINIMUM OF 50 SQUARE FEET PER TREE, WITH A MINIMUM DIMENSION OF FIVE FEET IN ORDER TO PROTECT THE LANDSCAPING AND ALLOW FOR PROPER GROWTH. WHEEL STOPS, CURBING OR OTHER BARRIERS SHALL BE PROVIDED TO PREVENT DAMAGE TO LANDSCAPING BY VEHICLES. WHERE NECESSARY, TREES SHALL BE WELLED OR OTHERWISE PROTECTED AGAINST CHANGE OF GRADE. ALL PERVIOUS AREAS OF THE SITE SHALL BE PERMANENTLY PROTECTED FROM SOIL EROSION WITH GRASS OR OTHER GROUND COVER OR MULCH MATERIAL. C.MAINTAINING AND REPLACING LANDSCAPING AND SCREENING. ALL LANDSCAPING AND SCREENING SHALL BE MAINTAINED IN A HEALTHY CONDITION BY THE CURRENT OWNER OR A PROPERTY OWNERS' ASSOCIATION, AND REPLACED WHEN NECESSARY. REPLACEMENT MATERIAL SHALL COMPLY WITH THE APPROVED LANDSCAPE PLAN. D.MAINTAINING TREES IF SITE NOT UNDER SINGLE OWNERSHIP. IN THE CASE OF DEVELOPMENT WITH UNITS FOR SALE, THE TREES SHALL BE MAINTAINED BY A PROPERTY OWNER'S ASSOCIATION. PRIOR TO FINAL SITE PLAN APPROVAL, THE DEVELOPER SHALL SUBMIT TO THE AGENT AN INSTRUMENT ASSURING THE PERPETUAL MAINTENANCE OF THE TREES. THE INSTRUMENT SHALL BE SUBJECT TO REVIEW AND APPROVAL BY THE COUNTY ATTORNEY AND SHALL BE IN A FORM AND STYLE SO THAT IT MAY BE RECORDED IN THE OFFICE OF THE CLERK OF THE CIRCUIT COURT OF THE COUNTY. THE AGENT MAY REQUIRE THAT THE INSTRUMENT BE ON A FORM PREPARED BY THE COUNTY ATTORNEY. E.MAINTAINING STREET TREES PLANTED WITHIN A PUBLIC STREET RIGHT-OF-WAY. IF STREET TREES ARE PLANTED WITHIN THE PUBLIC STREET RIGHT-OF-WAY, THE TREES SHALL BE MAINTAINED IN ACCORDANCE WITH THE REQUIREMENTS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION. FALL SITE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED TO REACH, AND BE MAINTAINED AT, MATURE HEIGHT; THE TOPPING OF TREES IS PROHIBITED. SHRUBS AND TREES SHALL BE PRUNED MINIMALLY AND ONLY TO SUPPORT THE OVERALL HEALTH OF THE PLANT. LANDSCAPE COMPLIANCE CHART SECTION REQUIREMENTS CALCULATIONS COMPLIANCE ONE (1) LARGE STREET TREE (A) SEMINOLE TRAIL U.S RTE 29 - SOUTHEAST PROPERTY LINE SHALL BE REQUIRED FOR EVERY FIFTY (50) FEET OF 153 LF STREET FRONTAGE STREET FRONTAGE, OR REQUIRED PORTION THEREOF, IF TWENTY-FIVE (25) FEET OR LARGE TREES REQUIRED: (1/50) X 153 = 3 LARGE TREES MORE. WHERE PERMITTED, SHRUBS REQUIRED: (1/5) X 153 = 31 SHRUBS ONE (1) MEDIUM SHADE TREE SHALL BE REQUIRED FOR EVERY FORTY (40) FEET OF PROVIDED 32.7.9.5 ROAD FRONTAGE, OR PORTION LARGE CANOPY TREES: 3 CANOPY TREES LANDSCAPING THEREOF, IF TWENTY (20) FEET SHRUBS PROVIDED: 32 SHRUBS COMPLIES ALONG OR MORE. IF REQUIRED STREETS STREET TREES CANNOT BE '1" INDICATED PLANT MATERIAL UTILIZED TO FULFIL THE REQUIREMENT PLANTED WITHIN THE PARKING SETBACK OR WITHIN TEN (10) FEET OF THE STREET RIGHT-OF-WAY DUE TO SIGHT DISTANCE, UTILITY EASEMENTS OR OTHER CONFLICTING REQUIREMENTS, THEN THE PLANTING STRIP SHALL BE ENLARGED TO ACCOMMODATE THE TREES. AN AREA OF AT LEAST (5) INTERIOR PARKING LOT LANDSCAPING PERCENT OF THE PAVED PARKING AND VEHICULAR PARKING LOT AREA: 29,869 SF CIRCULATION AREA SHALL BE PARKING SPACES: 32 LANDSCAPED WITH TREES OR REQUIRED 32.7.9.6 SHRUBS. PARKING LOT LANDSCAPE AREA: 5%X 29,948 SF = 1,497 SF LANDSCAPING CANOPY TREES:(1110) X 32 SPACES =4 CANOPY TREES COMPLIES WITHIN A PLANT MATERIALS MAY BE A PARKING AREA MIXTURE OF SHADE TEES AND PROVIDED SHRUBS AND SHALL INCLUDE ONE (1) LARGE SHADE TREE PARKING LOT LANDSCAPE AREA: 2,437 SF (8.14%) PER TEN (10) PARKING CANOPY TREES: 9 CANOPY TREES SPACES. W INDICATED PLANT MATERIAL UTILIZED TO FULFIL THE REQUIREMENT SCREENING LANDSCAPING COMMERCIAL AND INDUSTRIAL USES SHALL BE SCREENED FROM (B) SOUTHWEST PROPERTY LINE THE ADJACENT RURAL AREAS 397 LF PROPERTY LINE FRONTAGE ZONING DISTRICT. COMMERCIAL AND INDUSTRIAL USES SHALL BE REQUIRED SCREENED FROM RESIDENTIAL TREES REQUIRED: 0 X 397 LF SPACES = 0 TREES USES WHEN DEEMED NECESSARY SHRUBS REQUIRED: (1/5) X 2 X 153 = 159 SHRUBS BY THE AGENT UPON CONSIDERING THE PROXIMITY OF PROVIDED THE COMMERCIAL OR INDUSTRIAL TREES PROVIDED: 1 TREE USE TO THE RESIDENTIAL USE, SHRUBS PROVIDED: 161 SHRUBS THE NATURE OF THE COMMERCIAL "(DJ" INDICATED PLANT MATERIAL UTILIZED TO FULFIL THE REQUIREMENT OR INDUSTRIAL USE, WHETHER (C) NORTHWEST PROPERTY LINE THE USES ARE IN SINGLE -USE OR MIXED USE DEVELOPMENTS, AND 150 LF PROPERTY LINE FRONTAGE 32.7.9.7 OTHER CONSIDERATIONS HE REQUIRED SCREENING DETERMINES TO BE RELEVANT UNDER SOUND ZONING TREES REQUIRED: 0 X 150 LF SPACES = 0 TREES COMPLIES PRINCIPLES. SHRUBS REQUIRED: (1/5) X 2 X 150 = 60 SHRUBS PROVIDED TREES PROVIDED: 5 TREE SHRUBS PROVIDED: 60 SHRUBS "W INDICATED PLANT MATERIAL UTILIZED TO FULFIL THE REQUIREMENT (D) NORTHEAST PROPERTY LINE 366 LF PROPERTY LINE FRONTAGE REQUIRED TREES REQUIRED: 0 X 366 LF SPACES = 0 TREES SHRUBS REQUIRED: (1/5) X 2 X 366 = 147 SHRUBS PROVIDED TREES PROVIDED: 14 TREE SHRUBS PROVIDED: 147 SHRUBS TRASH ENCLOSURE WILL BE SCREENED BY 5 TREES "VINDICATED PLANT MATERIAL UTILIZED TO FULFIL THE REQUIREMENT COMMERCIAL AND INDUSTRIAL TREE CANOPY CALCULATION USES: IF THE SITE IS TO BE GROSS SITE AREA: 57,240 SF DEVELOPED FOR 32.7.9.8 COMMERCIAL OR INDUSTRIAL REQUIRED TREE CANOPY USES, THE MINIMUM TREE CANOPY AREA REQUIRED: 10% X 57,240 SF = 5,724 SF COMPLIES CANOPY IS TEN (10) PERCENT. PROVIDED CANOPY AREA PROVIDED: 7,654 SF TOTAL (13.37%) EXISTING CANOPY AREA: 0 SF PROPOSED CANOPY AREA: 7,654 SF LANDSCAPE SCHEDULE KEY QTY. BOTANICAL NAME COMMON NAME CAL. / HT. CONT. 10 YR CANOPY (SF) TOTAL CANOPY (SF) SHADETREES PLO 1 PIATANUS OCCIDENTALIS AMERICAN SYCAMORE 2-211T CAL I8-10' B+B 479 479 OP 12 QUERCUS PALUSTRIS PIN OAK 2-211Z CAL.18-10' B+B 471 5,652 SUBTOTAL: 13 SUBTOTAL 6,131 ORNAMENTALTREES U 1 LAGERSTROEMIA INDICA COMMON CRAPEMYRTLE 2-2112' CAL. 18-10' BIB 77 77 SUBTOTAL: I SUBTOTAL: 77 EVERGREEN TREES COD 4 CRYPTOMERIA JAPONICA JAPANESE CEDAR 8-19HE B+B 130 520 10 5 ILEX OPACA AMERICAN HOLLY 8-19 HT. B+B 56 280 O(N 9 ILEX X'NELLIE R. STEVEN' NELLIE R. STEVENTHOLLY 819 HT. B+B 44 396 PT 1 PINUS TAEDA LOSLOLLY PINE B-10 HT. B+B 250 250 SUBTOTAL: 19 SUBTOTAL: 1,446 DECIDUOUSSHRUBS CA 21 CLETHRAAUMFOLIA SUMMERSWEET CLETHRA 18-24'HT. & SPREAD OCAN NOT APPLICABLE DG 16 DEUTZM GRACILIS SLENDER DEUTZM 18-24"HT. & SPREAD W3 CAN NOTAPPLICABLE N 47 ITEAARGINICA'HENRY'S GARNET GARNET SWEETSPIRE 18-24'HT. & SPREAD #3 CAN NOT APPLICABLE RAGL 70 RHUSAROMATICA'GRQLOW GRO-LOWSUMAC 18-24'HT. & SPREAD g3CAN NOTAPPLICABLE VD 16 VIBURNUM DENTATUM ARROWWOOD VIBURNUM 16-24'HT. & SPREAD OCAN NOT APPLICABLE SUBTOTAL: 170 EVERGREEN SHRUBS ICBUR 11 ILEX CORNUTA'BURFORDII' BURFORD HOLLY 18-24"HT. & SPREAD g3CAN NOTAPPLICABLE ICC 27 ILEXCRENATA'COMPACTA' COMPACT JAPANESE HOLLY 18-24'HT. & SPREAD R3CAN NOTAPPLICABLE IDS 18 ILEXGIABRA'SHAMROCIC SHAMROCK INKBERRY HOLLY 18-24'HT. & SPREAD g3CAN NOTAPPLICABLE JCH 15 JUNIPERUS CHINENSIS'HETZII' HER JUNIPER 18-24'HT. & SPREAD OCAN NOT APPLICABLE RM 29 RHODODENDRON MAXIMUM'ROSEBAY' ROSEBAY RHODODENDRON 18-24"HT. & SPREAD OCAN NOT APPLICABLE SUBTOTAL: 100 PERENNIALS LSBS 625 URIOPE SPICATA CREEPINGURIOPE 1QT NOTAPPLICABLE SUBTOTAL: 625 ORNAMENTAL GRASSES PVHM 130 PANICUM VIRGATUM HEAVY METAL' HEAVY METAL SWITCH GRASS '2AL NOT APPLICABLE SUBTOTAL: 130 LANDSCAPE TRELLIS PLANTING KEY QTY. BOTANICAL NAME COMMONNAME CAL. HT. CONT. PC 45 PARTHENOCISSUS QUINQUEFOLIA VIRGINIA CREEPER 1GALLON MIN 0 Z D_ W LU LU U) Z F WLI Z W H 0 W 0zUjWW jW Fwax wz >z0LU00 7 Q co Z Z Q uzw<amo CL J 0 0� W Z z aQ > o- J of U W I-_ U) REVISIONS REV I DATE I COMMENT 1 110129120211 PER ISP COMMENTS I ' 2 101121120221 ER COUNTY COMMEENTS RTY 3 04/08/2022 PER COUNTY COMMENTS BSC RTY • Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: LSCP -2 PROJECT: SITE PLAN DOCUMENTS FOR nisca mu PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@,BohlerEng.com r NICHOLAS T GEOF ( r. Cert. No. 001653 8/27/2021 A SHEET TITLE: LANDSCAPE COMPLIANCE SHEET NUMBER: C-702 REVISION 3 - 04/08/2022 a a 3 W z N w 0 3 a N z z 3 9 a U LANDSCAPE SPECIFICATIONS 1. SCOPE OF WORK: 9. PLANTING THE LANDSCAPE CONTRACTOR SHALL BE REQUIRED TO PERFORM ALL CLEARING, FINISHED GRADING, SOIL A. INSOFAR THAT IT IS FEASIBLE, PLANT MATERIAL SHALL BE PLANTED ON THE DAY OF DELIVERY. IN THE EVENT PREPARATION, PERMANENT SEEDING OR SODDING, PLANTING AND MULCHING INCLUDING ALL LABOR, MATERIALS, THAT THIS IS NOT POSSIBLE, LANDSCAPE CONTRACTOR SHALL PROTECT UNINSTALLED PLANT MATERIAL. TOOLS AND EQUIPMENT NECESSARY FOR THE COMPLETION OF THIS PROJECT, UNLESS OTHERWISE CONTRACTED BY PLANTS SHALL NOT REMAIN UNPLANTED FOR LONGER THAN A THREE DAY PERIOD AFTER DELIVERY. PLANTS THE GENERAL CONTRACTOR. THAT WILL NOT BE PLANTED FOR A PERIOD OF TIME GREATER THAN THREE DAYS SHALL BE HEALED IN WITH TOPSOIL OR MULCH TO HELP PRESERVE ROOT MOISTURE. 2. MATERIALS A. GENERAL - ALL HARDSCAPE MATERIALS SHALL MEET OR EXCEED SPECIFICATIONS AS OUTLINED IN THE STATE B. PLANTING OPERATIONS SHALL BE PERFORMED DURING PERIODS WITHIN THE PLANTING SEASON WHEN DEPARTMENT OF TRANSPORTATION'S SPECIFICATIONS. WEATHER AND SOIL CONDITIONS ARE SUITABLE AND IN ACCORDANCE WITH ACCEPTED LOCAL PRACTICE. PLANTS SHALL NOT BE INSTALLED IN TOPSOIL THAT IS IN A MUDDY OR FROZEN CONDITION. B. TOPSOIL - NATURAL, FRIABLE, LOAMY SILT SOIL HAVING AN ORGANIC CONTENT NOT LESS THAN 5%, A PH RANGE BETWEEN 4.5-7.0. IT SHALL BE FREE OF DEBRIS, ROCKS LARGER THAN ONE INCH (1"), WOOD, ROOTS, VEGETABLE C. ANY INJURED ROOTS OR BRANCHES SHALL BE PRUNED TO MAKE CLEAN-CUT ENDS PRIOR TO PLANTING MATTER AND CLAY CLODS. UTILIZING CLEAN, SHARP TOOLS. ONLY INJURED OR DISEASED BRANCHING SHALL BE REMOVED. C. LAWN - ALL DISTURBED AREAS ARE TO BE TREATED WITH A MINIMUM SIX INCH 6" THICK LAYER OF TOPSOIL OR D. ALL PLANTING CONTAINERS AND NON -BIODEGRADABLE MATERIALS SHALL BE REMOVED FROM ROOT BALLS AS DIRECTED BY THE LOCAL ORDINANCE OR CLIENT, AND SEEDED OR SODDED IN ACCORDANCE WITH THE DURING PLANTING. NATURAL FIBER BURLAP MUST BE CUT FROM AROUND THE TRUNK OF THE TREE AND FOLDED PERMANENT STABILIZATION METHODS INDICATED WITHIN THE SOIL EROSION AND SEDIMENT CONTROL NOTES. DOWN AGAINST THE ROOT BALL PRIOR TO BACKFILLING. 1.1. LAWN SEED MIXTURE SHALL BE FRESH, CLEAN NEW CROP SEED. 1.2. SOD SHALL BE STRONGLY ROOTED WEED AND DISEASEIPEST FREE WITH A UNIFORM THICKNESS. E. POSITION TREES AND SHRUBS AT THEIR INTENDED LOCATIONS AS PER THE PLANS AND SECURE THE APPROVAL 1.3. SOD INSTALLED ON SLOPES GREATER THAN 4:1 SHALL BE PEGGED TO HOLD SOD IN PLACE. OF THE LANDSCAPE ARCHITECT PRIOR TO EXCAVATING PITS MAKING NECESSARY ADJUSTMENTS AS DIRECTED. D. MULCH - THE MULCH AROUND THE PERIMETER OF THE BUILDING SHALL BE A 3" LAYER OF DOUBLE SHREDDED F. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, THE PROPOSED LANDSCAPE, AS SHOWN ON THE BLACK CEDAR MULCH ONLY. ALL OTHER AREAS SHALL BE MULCHED WITH A 3" LAYER OF DOUBLE SHREDDED APPROVED LANDSCAPE PLAN, MUST BE INSTALLED, INSPECTED AND APPROVED BY THE APPROVING AGENCY. DARK BROWN HARDWOOD BARK MULCH UNLESS OTHERWISE STATED ON THE LANDSCAPE PLAN. THE APPROVING AGENCY SHALL TAKE INTO ACCOUNT SEASONAL CONSIDERATIONS IN THIS REGARD AS FOLLOWS. THE PLANTING OF TREES, SHRUBS, VINES OR GROUND COVER SHALL OCCUR ONLY DURING THE E. FERTILIZER FOLLOWING PLANTING SEASONS: 1.1. FERTILIZER SHALL BE DELIVERED TO THE SITE MIXED AS SPECIFIED IN THE ORIGINAL UNOPENED STANDARD 1.1. PLANTS: MARCH 15 TO DECEMBER 15 BAGS SHOWING WEIGHT, ANALYSIS AND NAME OF MANUFACTURER. FERTILIZER SHALL BE STORED IN A 1.2. LAWN: MARCH 15 TO JUNE 15 OR SEPT. 1 TO DECEMBER 1 WEATHERPROOF PLACE SO THAT IT CAN BE KEPT DRY PRIOR TO USE. 1.2. FOR THE PURPOSE OF BIDDING, ASSUME THAT FERTILIZER SHALL BE 10% NITROGEN, 6% PHOSPHORUS AND G. PLANTINGS REQUIRED FOR A CERTIFICATE OF OCCUPANCY SHALL BE PROVIDED DURING THE NEXT 4% POTASSIUM BY WEIGHT. A FERTILIZER SHOULD NOT BE SELECTED WITHOUT A SOIL TEST PERFORMED BY APPROPRIATE SEASON AT THE MUNICIPALITY'S DISCRETION. CONTRACTOR SHOULD CONTACT APPROVING A CERTIFIED SOIL LABORATORY. AGENCY FOR POTENTIAL SUBSTITUTIONS. F. PLANT MATERIAL H. FURTHERMORE, THE FOLLOWING TREE VARIETIES ARE UNUSUALLY SUSCEPTIBLE TO WINTER DAMAGE. WITH 1.1. ALL PLANTS SHALL IN ALL CASES CONFORM TO THE REQUIREMENTS OF THE "AMERICAN STANDARD FOR TRANSPLANT SHOCK AND THE SEASONAL LACK OF NITROGEN AVAILABILITY, THE RISK OF PLANT DEATH IS NURSERY STOCK" (ANSI Z60.1), LATEST EDITION, AS PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPE GREATLY INCREASED. IT IS NOT RECOMMENDED THAT THESE SPECIES BE PLANTED DURING THE FALL PLANTING ASSOCIATION. SEASON: 1.2. IN ALL CASES, BOTANICAL NAMES SHALL TAKE PRECEDENCE OVER COMMON NAMES FOR ANY AND ALL ACER RUBRUM PLATANUS X ACERIFOLIA PLANT MATERIAL. BETULA VARIETIES POPULOUS VARIETIES 1.3. PLANTS SHALL BE LEGIBLY TAGGED WITH THE PROPER NAME AND SIZE. TAGS ARE TO REMAIN ON AT LEAST CARPINUS VARIETIES PRUNUS VARIETIES ONE PLANT OF EACH SPECIES FOR VERIFICATION PURPOSES DURING THE FINAL INSPECTION. CRATAEGUS VARIETIES PYRUS VARIETIES 1.4. TREES WITH ABRASION OF THE BARK, SUN SCALDS, DISFIGURATION OR FRESH CUTS OF LIMBS OVER 1W, KOELREUTERIA QUERCUS VARIETIES WHICH HAVE NOT BEEN COMPLETELY CALLUSED, SHALL BE REJECTED.PLANTS SHALL NOT BE BOUND WITH LIQUIDAMBER STYRACIFLUA TILIA TOMENTOSA WIRE OR ROPE AT ANY TIME SO AS TO DAMAGE THE BARK OR BREAK BRANCHES. LIRIODENDRON TULIPIFERA ZELKOVA VARIETIES 1.5. ALL PLANTS SHALL BE TYPICAL OF THEIR SPECIES OR VARIETY AND SHALL HAVE A NORMAL HABIT OF GROWTH: WELL DEVELOPED BRANCHES, DENSELY FOLIATED, VIGOROUS ROOT SYSTEMS AND BE FREE OF I. PLANTING PITS SHALL BE DUG WITH LEVEL BOTTOMS, WITH THE WIDTH TWICE THE DIAMETER OF ROOT BALL. DISEASE, INSECTS, PESTS, EGGS OR LARVAE. THE ROOT BALL SHALL REST ON UNDISTURBED GRADE. EACH PLANT PIT SHALL BE BACKFILLED IN LAYERS WITH 1.6. CALIPER MEASUREMENTS OF NURSERY GROWN TREES SHALL BE TAKEN AT A POINT ON THE TRUNK SIX THE FOLLOWING PREPARED SOIL MIXED THOROUGHLY: INCHES (6") ABOVE THE NATURAL GRADE FOR TREES UP TO AND INCLUDING A FOUR INCH (4') CALIPER SIZE. • 1 PART PEAT MOSS IF THE CALIPER AT SIX INCHES (6") ABOVE THE GROUND EXCEEDS FOUR INCHES (4") IN CALIPER, THE • 1 PART COMPOSTED COW MANURE BY VOLUME CALIPER SHOULD BE MEASURED AT A POINT 12" ABOVE THE NATURAL GRADE. • 3 PARTS TOPSOIL BY VOLUME 1.7. SHRUBS SHALL BE MEASURED TO THE AVERAGE HEIGHT OR SPREAD OF THE SHRUB, AND NOT TO THE • 21 GRAMS'AGRIFORM' PLANTING TABLETS (OR APPROVED EQUAL) AS FOLLOWS: LONGEST BRANCH. A) 2 TABLETS PER 1 GALLON PLANT 1.8. TREES AND SHRUBS SHALL BE HANDLED WITH CARE BY THE ROOT BALL. B) 3 TABLETS PER 5 GALLON PLANT C) 4 TABLETS PER 15 GALLON PLANT 3. GENERAL WORK PROCEDURES D) LARGER PLANTS: 2 TABLETS PER'IW CALIPER OF TRUNK A. CONTRACTOR TO UTILIZE WORKMANLIKE INDUSTRY STANDARDS IN PERFORMING ALL LANDSCAPE CONSTRUCTION. THE SITE IS TO BE LEFT IN A CLEAN STATE AT THE END OF EACH WORKDAY. ALL DEBRIS, J. FILL PREPARED SOIL AROUND BALL OF PLANT HALF -WAY AND INSERT PLANT TABLETS. COMPLETE BACKFILL AND MATERIALS AND TOOLS SHALL BE PROPERLY STORED, STOCKPILED OR DISPOSED OF. WATER THOROUGHLY. B. WASTE MATERIALS AND DEBRIS SHALL BE COMPLETELY DISPOSED OF AT THE CONTRACTOR'S EXPENSE. DEBRIS K. ALL PLANTS SHALL BE PLANTED SO THAT THE TOP OF THE ROOT BALL, THE POINT AT WHICH THE ROOT FLARE SHALL NOT BE BURIED, INCLUDING ORGANIC MATERIALS, BUT SHALL BE REMOVED COMPLETELY FROM THE SITE. BEGINS, IS SET AT GROUND LEVEL AND IN THE CENTER OF THE PIT. NO SOIL IS TO BE PLACED DIRECTLY ON TOP OF THE ROOT BALL. 4. SITE PREPARATIONS A. BEFORE AND DURING PRELIMINARY GRADING AND FINISHED GRADING, ALL WEEDS AND GRASSES SHALL BE DUG L. ALL PROPOSED TREES DIRECTLY ADJACENT TO WALKWAYS OR DRIVEWAYS SHALL BE PRUNED AND MAINTAINED OUT BY THE ROOTS AND DISPOSED OF IN ACCORDANCE WITH GENERAL WORK PROCEDURES OUTLINED HEREIN. TO A MINIMUM BRANCHING HEIGHT OF T FROM GRADE. B. ALL EXISTING TREES TO REMAIN SHALL BE PRUNED TO REMOVE ANY DAMAGED BRANCHES. THE ENTIRE LIMB OF M. GROUND COVER AREAS SHALL RECEIVE A W LAYER OF HUMUS RAKED INTO THE TOP 1" OF PREPARED SOIL ANY DAMAGED BRANCH SHALL BE CUT OFF AT THE TRUNK. CONTRACTOR SHALL ENSURE THAT CUTS ARE PRIOR TO PLANTING. ALL GROUND COVER AREAS SHALL BE WEEDED AND TREATED WITH A PRE -EMERGENT SMOOTH AND STRAIGHT. ANY EXPOSED ROOTS SHALL BE CUT BACK WITH CLEAN, SHARP TOOLS AND TOPSOIL CHEMICAL AS PER MANUFACTURER'S RECOMMENDATION. SHALL BE PLACED AROUND THE REMAINDER OF THE ROOTS. EXISTING TREES SHALL BE MONITORED ON A REGULAR BASIS FOR ADDITIONAL ROOT OR BRANCH DAMAGE AS A RESULT OF CONSTRUCTION. ROOTS SHALL N. NO PLANT, EXCEPT GROUND COVERS, GRASSES OR VINES, SHALL BE PLANTED LESS THAN TWO FEET (2') FROM NOT BE LEFT EXPOSED FOR MORE THAN ONE (1) DAY. CONTRACTOR SHALL WATER EXISTING TREES AS NEEDED EXISTING STRUCTURES AND SIDEWALKS. TO PREVENT SHOCK OR DECLINE. O. ALL PLANTING AREAS AND PLANTING PITS SHALL BE MULCHED AS SPECIFIED HEREIN TO FILL THE ENTIRE BED C. CONTRACTOR SHALL ARRANGE TO HAVE A UTILITY STAKE -OUT TO LOCATE ALL UNDERGROUND UTILITIES PRIOR AREA OR SAUCER. NO MULCH IS TO TOUCH THE TRUNK OF THE TREE OR SHRUB. TO INSTALLATION OF ANY LANDSCAPE MATERIAL. UTILITY COMPANIES SHALL BE CONTACTED THREE (3) DAYS PRIOR TO THE BEGINNING OF WORK. P. ALL PLANTING AREAS SHALL BE WATERED IMMEDIATELY UPON INSTALLATION IN ACCORDANCE WITH THE WATERING SPECIFICATIONS AS LISTED HEREIN. 5. TREE PROTECTION A. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING TREES TO REMAIN. A TREE 10. TRANSPLANTING (WHEN REQUIRED) PROTECTION ZONE SHALL BE ESTABLISHED AT THE DRIP LINE OR 15 FEET FROM THE TRUNK OR AT THE LIMIT OF A. ALL TRANSPLANTS SHALL BE DUG WITH INTACT ROOT BALLS CAPABLE OF SUSTAINING THE PLANT. CONSTRUCTION DISTURBANCE, WHICHEVER IS GREATER. LOCAL STANDARDS THAT MAY REQUIRE A MORE STRICT TREE PROTECTION ZONE SHALL BE HONORED. B. IF PLANTS ARE TO BE STOCKPILED BEFORE REPLANTING, THEY SHALL BE HEALED IN WITH MULCH OR SOIL, ADEQUATELY WATERED AND PROTECTED FROM EXTREME HEAT, SUN AND WIND. B. A FORTY-EIGHT INCH (48') HIGH WOODEN SNOW FENCE OR ORANGE COLORED HIGH-DENSITY'VISI-FENCE', OR APPROVED EQUAL, MOUNTED ON STEEL POSTS SHALL BE PLACED ALONG THE BOUNDARY OF THE TREE C. PLANTS SHALL NOT BE DUG FOR TRANSPLANTING BETWEEN APRIL 10 AND JUNE 30. PROTECTION ZONE. POSTS SHALL BE LOCATED AT A MAXIMUM OF EIGHT FEET (8) ON CENTER OR AS INDICATED WITHIN THE TREE PROTECTION DETAIL. D. UPON REPLANTING, BACKFILL SOIL SHALL BE AMENDED WITH FERTILIZER AND ROOT GROWTH HORMONE. C. WHEN THE TREE PROTECTION FENCING HAS BEEN INSTALLED, IT SHALL BE INSPECTED BY THE APPROVING E. TRANSPLANTS SHALL BE GUARANTEED FOR THE LENGTH OF THE GUARANTEE PERIOD SPECIFIED HEREIN. AGENCY PRIOR TO DEMOLITION, GRADING, TREE CLEARING OR ANY OTHER CONSTRUCTION. THE FENCING ALONG THE TREE PROTECTION ZONE SHALL BE REGULARLY INSPECTED BY THE LANDSCAPE CONTRACTOR AND F. IF TRANSPLANTS DIE, SHRUBS AND TREES LESS THAN SIX INCHES (6") DBH SHALL BE REPLACED IN KIND. TREES MAINTAINED UNTIL ALL CONSTRUCTION ACTIVITY HAS BEEN COMPLETED. GREATER THAN SIX INCHES (6") DBH MAY BE REQUIRED TO BE REPLACED IN ACCORDANCE WITH THE MUNICIPALITY'S TREE REPLACEMENT GUIDELINES. D. AT NO TIME SHALL MACHINERY, DEBRIS, FALLEN TREES OR OTHER MATERIALS BE PLACED, STOCKPILED OR LEFT STANDING IN THE TREE PROTECTION ZONE. 11. WATERING A. NEW PLANTINGS OR LAWN AREAS SHALL BE ADEQUATELY IRRIGATED BEGINNING IMMEDIATELY AFTER PLANTING. 6. SOIL MODIFICATIONS WATER SHALL BE APPLIED TO EACH TREE AND SHRUB IN SUCH MANNER AS NOT TO DISTURB BACKFILL AND TO A. CONTRACTOR SHALL ATTAIN A SOIL TEST FOR ALL AREAS OF THE SITE PRIOR TO CONDUCTING ANY PLANTING. THE EXTENT THAT ALL MATERIALS IN THE PLANTING HOLE ARE THOROUGHLY SATURATED. WATERING SHALL SOIL TESTS SHALL BE PERFORMED BY A CERTIFIED SOIL LABORATORY. CONTINUE AT LEAST UNTIL PLANTS ARE ESTABLISHED. B. LANDSCAPE CONTRACTOR SHALL REPORT ANY SOIL OR DRAINAGE CONDITIONS CONSIDERED DETRIMENTAL TO B. SITE OWNER SHALL PROVIDE WATER IF AVAILABLE ON SITE AT TIME OF PLANTING. IF WATER IS NOT AVAILABLE THE GROWTH OF PLANT MATERIAL. SOIL MODIFICATIONS, AS SPECIFIED HEREIN, MAY NEED TO BE CONDUCTED ON SITE, CONTRACTOR SHALL SUPPLY ALL NECESSARY WATER. THE USE OF WATERING BAGS IS RECOMMENDED BY THE LANDSCAPE CONTRACTOR DEPENDING ON SITE CONDITIONS. FOR ALL NEWLY PLANTED TREES. C. THE FOLLOWING AMENDMENTS AND QUANTITIES ARE APPROXIMATE AND ARE FOR BIDDING PURPOSES ONLY. C. IF AN IRRIGATION SYSTEM HAS BEEN INSTALLED ON THE SITE, IT SHALL BE USED TO WATER PROPOSED PLANT COMPOSITION OF AMENDMENTS SHOULD BE REVISED DEPENDING ON THE OUTCOME OF A TOPSOIL ANALYSIS MATERIAL, BUT ANY FAILURE OF THE SYSTEM DOES NOT ELIMINATE THE CONTRACTOR'S RESPONSIBILITY OF PERFORMED BY A CERTIFIED SOIL LABORATORY. MAINTAINING THE DESIRED MOISTURE LEVEL FOR VIGOROUS, HEALTHY GROWTH. 1.1. TO INCREASE A SANDY SOIL'S ABILITY TO RETAIN WATER AND NUTRIENTS, THOROUGHLY TILL ORGANIC MATTER INTO THE TOP 6-12". USE COMPOSTED BARK, COMPOSTED LEAF MULCH OR PEAT MOSS. ALL 12. GUARANTEE PRODUCTS SHOULD BE COMPOSTED TO A DARK COLOR AND BE FREE OF PIECES WITH IDENTIFIABLE LEAF A. THE LANDSCAPE CONTRACTOR SHALL GUARANTEE ALL PLANTS FOR A PERIOD OF ONE (1) YEAR FROM APPROVAL OR WOOD STRUCTURE. AVOID MATERIAL WITH A PH HIGHER THAN 7.5. OF LANDSCAPE INSTALLATION BY THE APPROVING AGENCY. CONTRACTOR SHALL SUPPLY THE OWNER WITH A 1.2. TO INCREASE DRAINAGE, MODIFY HEAVY CLAY OR SILT (MORE THAN 40% CLAY OR SILT) BY ADDING MAINTENANCE BOND FOR TEN PERCENT (10%) OF THE VALUE OF THE LANDSCAPE INSTALLATION WHICH WILL BE COMPOSTED PINE BARK (UP TO 30% BY VOLUME) AND/OR AGRICULTURAL GYPSUM. COARSE SAND MAY BE RELEASED AT THE CONCLUSION OF THE GUARANTEE PERIOD AND WHEN A FINAL INSPECTION HAS BEEN USED IF ENOUGH IS ADDED TO BRING THE SAND CONTENT TO MORE THAN 60% OF THE TOTAL MIX. COMPLETED AND APPROVED BY THE OWNER OR AUTHORIZED REPRESENTATIVE. SUBSURFACE DRAINAGE LINES MAY NEED TO BE ADDED TO INCREASE DRAINAGE. 1.3. MODIFY EXTREMELY SANDY SOILS (MORE THAN 85%) BY ADDING ORGANIC MATTER AND/OR DRY, SHREDDED B. ANY DEAD OR DYING PLANT MATERIAL SHALL BE REPLACED FOR THE LENGTH OF THE GUARANTEE PERIOD. CLAY LOAM UP TO 30% OF THE TOTAL MIX. REPLACEMENT OF PLANT MATERIAL SHALL BE CONDUCTED AT THE FIRST SUCCEEDING PLANTING SEASON. ANY DEBRIS SHALL BE DISPOSED OF OFFSITE, WITHOUT EXCEPTION. 7. FINISHED GRADING A. UNLESS OTHERWISE CONTRACTED, THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR THE C. TREES AND SHRUBS SHALL BE MAINTAINED BY THE CONTRACTOR DURING CONSTRUCTION AND THROUGHOUT INSTALLATION OF TOPSOIL AND THE ESTABLISHMENT OF FINE -GRADING WITHIN THE DISTURBANCE AREA OF THE THE 90 DAY MAINTENANCE PERIOD AS SPECIFIED HEREIN. CULTIVATION, WEEDING, WATERING AND THE SITE. PREVENTATIVE TREATMENTS SHALL BE PERFORMED AS NECESSARY TO KEEP PLANT MATERIAL IN GOOD CONDITION AND FREE OF INSECTS AND DISEASE. B. LANDSCAPE CONTRACTOR SHALL VERIFY THAT SUBGRADE FOR INSTALLATION OF TOPSOIL HAS BEEN ESTABLISHED. THE SUBGRADE OF THE SITE MUST MEET THE FINISHED GRADE LESS THE REQUIRED TOPSOIL D. LAWNS SHALL BE MAINTAINED THROUGH WATERING, FERTILIZING, WEEDING, MOWING, TRIMMING AND OTHER THICKNESS (1"t). OPERATIONS SUCH AS ROLLING, REGARDING AND REPLANTING AS REQUIRED TO ESTABLISH A SMOOTH, ACCEPTABLE LAWN, FREE OF ERODED OR BARE AREAS. C. ALL LAWN AND PLANTING AREAS SHALL BE GRADED TO A SMOOTH, EVEN AND UNIFORM PLANE WITH NO ABRUPT CHANGE OF SURFACE AS DEPICTED WITHIN THIS SET OF CONSTRUCTION PLANS, UNLESS OTHERWISE DIRECTED 13. CLEANUP BY THE PROJECT ENGINEER OR LANDSCAPE ARCHITECT. A. UPON THE COMPLETION OF ALL LANDSCAPE INSTALLATION AND BEFORE THE FINAL ACCEPTANCE, THE CONTRACTOR SHALL REMOVE ALL UNUSED MATERIALS, EQUIPMENT AND DEBRIS FROM THE SITE. ALL PAVED D. ALL PLANTINGAREA HALL BE GRADED AND MAINTAINED T ALLOW FREE FLOW F SURFACE WATER IN AND SS G O O O O SU C AREAS ARE TO BE CLEANED. AROUND THE PLANTING BEDS. STANDING WATER SHALL NOT BE PERMITTED IN PLANTING BEDS. B. THE SITE SHALL BE CLEANED AND LEFT IN A NEAT AND ACCEPTABLE CONDITION AS APPROVED BY THE OWNER 8. TOPSOILING OR AUTHORIZED REPRESENTATIVE. A. CONTRACTOR SHALL PROVIDE A SIX INCH (6' THICK MINIMUM LAYER OF TOPSOIL, OR AS DIRECTED BY THE LOCAL ORDINANCE OR CLIENT, IN ALL PLANTING AREAS. TOPSOIL SHOULD BE SPREAD OVER A PREPARED SURFACE IN A UNIFORM LAYER TO ACHIEVE THE DESIRED COMPACTED THICKNESS. B. ON -SITE TOPSOIL MAY BE USED TO SUPPLEMENT THE TOTAL AMOUNT REQUIRED. TOPSOIL FROM THE SITE MAY BE REJECTED IF IT HAS NOT BEEN PROPERLY REMOVED, STORED AND PROTECTED PRIOR TO CONSTRUCTION. C. CONTRACTOR SHALL FURNISH TO THE APPROVING AGENCY AN ANALYSIS OF BOTH IMPORTED AND ON -SITE TOPSOIL TO BE UTILIZED IN ALL PLANTING AREAS. THE PH AND NUTRIENT LEVELS MAY NEED TO BE ADJUSTED THROUGH SOIL MODIFICATIONS AS NEEDED TO ACHIEVE THE REQUIRED LEVELS AS SPECIFIED IN THE MATERIALS SECTION ABOVE. D. ALL PLANTING AND LAWN AREAS ARE TO BE CULTIVATED TO A DEPTH OF SIX INCHES (6"). ALL DEBRIS EXPOSED FROM EXCAVATION AND CULTIVATION SHALL BE DISPOSED OF IN ACCORDANCE WITH GENERAL WORK PROCEDURES SECTION ABOVE. THE FOLLOWING SHALL BE TILLED INTO THE TOP FOUR INCHES (4' IN TWO DIRECTIONS (QUANTITIES BASED ON A 1,000 SQUARE FOOT AREA): 1.1. 20 POUNDS'GROW POWER' OR APPROVED EQUAL 1.2. 20 POUNDS NITRO -FORM (COURSE) 38-0-0 BLUE CHIP E. THE SPREADING OF TOPSOIL SHALL NOT BE CONDUCTED UNDER MUDDY OR FROZEN CONDITIONS. ONLY TREES WITH ONE MAIN LEADER SHALL BE PURCHASED. DO NOT PRUNE TREE AT PLANTING UNLESS DIRECTED TO BY PROJECT LANDSCAPE ARCHITECT DO NOT STAKE OR FOLD BURLAP AWAY FROM TOP OF WRAPTRUNK ROOT BALL PREPARE WIDTH OF SET ROOT BALL FLUSH TO GRADE OR PLANTING HOLE 6 FT SEVERAL INCHES HIGHER IN OR TWICE THE WIDTH POORLY DRAINING SOILS. OF THE ROOT BALL; WHICHEVER IS 4" BUILT-UP EARTH SAUCER GREATER 3" THICK LAYER OF DARK BROWN DOUBLE SHREDDED PREPARED SOIL FOR HARDWOOD MULCH TREES 1 PART PEAT MOSS 1 BEFORE PLANTING ADD 3 TO 4" PART COW MANURE 3 OF WELL -COMPOSTED LEAVES PARTS TOPSOIL OR RECYCLED YARD WASTE TO BED AND TILL INTO TOP 6" OF I PREPARED SOIL. -I - UNDISTURBED I— — — — 46" DEEPER THAN ROOT BALL SUBGRADE REMOVE THE TOP 113 OF THE WIRE BASKET IF PRESENT. ANY AND ALL TWINE SHALL BE REMOVED DIG WIDE, SHALLOW HOLE FROM THE TREE BEFORE BACKFILLING. BURLAP SHALL WITH TAMPED SIDES BE FOLDED BACK INTO PLANTING HOLE TAMP SOIL SOLIDLY AROUND BASE OF ROOT BALL SET ROOT BALL ON FIRM PAD IN BOTTOM OF HOLE REFERENCE: ARCHITECTURAL GRAPHIC STANDARDS 1998 CUMULATIVE SUPPLEMENT. EVERGREEN TREE PLANTING DETAIL NOT TO SCALE DO NOT STAKE OR WRAP TRUNK PREPARE WIDTH OF PLANTING HOLE 6 FT OR TWICE THE WIDTH OF THE ROOT BALL; WHICHEVER IS GREATER PREPARED SOIL FOR TREES 1 PART PEAT MOSS 1 PART COW MANURE 3 PARTS TOPSOIL SUBGRADE DIG WIDE, SHALLOW HOLE WITH TAMPED SIDES TAMP SOIL SOLIDLY AROUND BASE OF ROOT BALL PLANT SHALL BE TRANSPLANTED AT THE SAME GRADE AS IT BORE IN THE NURSERY PLOT PRIOR TO BALLING AND BURLAPPING. PLANTING MIX: — 1 PART PEAT MOSS 1 PART COW MANURE 3 PARTS TOPSOIL PLANTING MIXTURE WILL CHANGE WITH SOIL CONDITIONS BEFORE PLANTING, ADD 3 TO 4" OF WELL -COMPOSTED LEAVES AND RECYCLED YARD WASTE TO BED AND TILL INTO TOP 6" OF PREPARED SOIL REMOVE THE TOP 1/3 OF THE WIRE BASKET IF PRESENT. ANY AND ALL TWINE SHALL BE REMOVED FROM THE SHRUB BEFORE BACKFILLING. BURLAP SHALL BE FOLDED BACK INTO PLANTING HOLE ONLY TREES WITH ONE MAIN LEADER a o ° YY�IIjII�(ry ° SHALL BE PURCHASED. DO NOT PRUNE TREE AT PLANTING UNLESS DIRECTED TO BY PROJECT LANDSCAPE ARCHITECT FOLD BURLAP AWAY FROM TOP OF ROOT BALL `ad SET ROOT BALL FLUSH TO GRADE (° OR SEVERAL INCHES HIGHER IN POORLY DRAINING SOILS. 4" BUILT-UP EARTH SAUCER 3" THICK LAYER OF DARK BROWN DOUBLE SHREDDED HARDWOOD MULCH BEFORE PLANTING ADD 3 TO 4" OF WELL -COMPOSTED LEAVES OR RECYCLED YARD WASTE TO BED AND TILL INTO TOP 6" OF PREPARED SOIL. 4-6" DEEPER THAN ROOT BALL REMOVE THE TOP 1/3 OF THE WIRE BASKET IF PRESENT. ANY AND ALL TWINE SHALL BE REMOVED FROM THE TREE BEFORE BACKFILLING. BURLAP SHALL BE FOLDED BACK INTO PLANTING HOLE SET ROOT BALL ON FIRM PAD IN BOTTOM OF HOLE REFERENCE: ARCHITECTURAL GRAPHIC STANDARDS 1998 CUMULATIVE SUPPLEMENT. DECIDUOUS TREE PLANTING DETAIL NOT TO SCALE 8-12" REFERENCE: ARCHITECTURAL GRAPHIC STANDARDS 1998 CUMULATIVE SUPPLEMENT DECIDUOUS AND EVERGREEN SHRUB PLANTING DETAIL NOT TO SCALE INCORPORATE T OF PEAT INTO 6' OF PLANTING MIXTURE, AS SPECIFIED 3" THICK LAYER OF DARK BROWN DOUBLE SHREDDED HARDWOOD MULCH —� Itl@11.971711 MINIMUM 6" FOR CONTAINER -GROWN SHRUBS, USE FINGER OR SMALL HAND TOOLS TO PULL THE ROOTS OUT OF THE OUTER LAYER OF POTTING SOIL; THEN CUT OR PULL APART ANY ROOTS THAT CIRCLE THE PERIMETER OF THE CONTAINER 3" THICK LAYER OF DARK BROWN DOUBLE SHREDDED HARDWOOD MULCH FINISHED GRADE PLACE SHRUB ON FIRM SOIL IN BOTTOM OF HOLE. SUBGRADE SOIL SURFACE ROUGHENED TO BIND WITH NEW SOIL. PLANT MATERIAL SPACED AS SPECIFIED. SEE LANDSCAPE SCHEDULE FOR PROPOSED SPACING. —1I1=1I1== =III III—' II TYPICAL PERENNIAL AND GROUND COVER PLANTING D= PROPOSED ON CENTER (D.C.) SPACING SEE LANDSCAPE SCHEDULE FOR FOR REQUIRED SPACING NOTE: TREE STAKING TO BE REMOVED AFTER 2 GROWING SEASONS o 0 °dd p° d O" DO NOT WRAP TRUNK REINFORCED RUBBER HOSE (1/2" ° ONLY TREES WITH ONE MAIN LEADER SHALL BE DIA) PURCHASED. DO NOT PRUNE TREE AT PLANTING 12 GAUGE GALVANIZED WIRE GUYS TWISTED ° °p° UNLESS DIRECTED TO BY PROJECT LANDSCAPE ARCHITECT T DIA. HARDWOOD STAKES 2/3 TREE HT. a 2 PER TREE SET ROOT BALL FLUSH TO GRADE OR W EXISTING GRADE SEVERAL INCHES HIGHER IN POORLY DRAINING SOILS. PREPARED SOIL FOR TREE — _� 1 PART PEAT MOSS 3 C 0 LAYER0 "THI K F DARK BR WN 1 PART COW MANURE III= DOUBLE SHREDDED HARDWOOD 3 PARTS TOPSOIL MULCH UNDISTURBED SUBGRADE II _- -I 4' BUILT-UP EARTH SAUCER _ - BEFORE PLANTING ADD 3 TO 4' OF WELL -COMPOSTED LEAVES OR RECYCLED YARD WASTE TO BED AND TILL M� T INTO TOP 6' OF PREPARED SOIL. REMOVE THE TOP 1/3 OF THE WIRE BASKET IF PRESENT. ANY AND ALL TWINE SHALL BE REMOVED O 12' � Lr FROM THE TREE BEFORE BACKFILLING. BURLAP SHALL TAMP SOIL SOLIDLY AROUND BASE BE FOLDED BACK INTO PLANTING HOLE OF ROOT BALL SET ROOT BALL ON FIRM PAD IN BOTTOM OF HOLE TREE PLANTING ON SLOPE DETAIL NOT TO SCALE SEEDING SPECIFICATIONS 1. MATERIAL: 1.1. SEED MIXTURE MUST BE COMPRISED OF THE FOLLOWING VARIETIES AND AT THE SPECIFIED COMPOSITION: 1.1.1. 80% - TURF TYPE TALL FESCUE SEED 1.1.2. 10%- KENTUCKY BLUEGRASS SEED 1.1.3. 10%-ANNUAL RYE GRASS SEED 12. INSTALLATION RATES: 1.2.1. SEED: LAWN SEED SHOULD BE APPLIED AT A RATE OF 7 LBS/1,000 SF 1.2.2. LIME: AGRICULTURAL OR PELLETIZED LIME SHOULD BE APPLIED AT SPECIFIED RATE ACCORDING TO SOIL ANALYSIS OR 2,000 LBS PER ACRE (46 LBS/1,000 SF) IF NO SOIL ANALYSIS IS PERFORMED. 1.2.3. FERTILIZER: COMMERCIAL GRADE 12-20-12 SHOULD BE APPLIED AT A RATE OF 250 LBS PER PER ACRE (5.8 LBS/ 1,000 SF) 1.2.4. LIQUID OR DRY LIME: LIQUID LIME SHOULD BE APPLIED AT A RATE OF 2.5 GALLONS PER ACRE OR NEUTRA LIME DRY APPLIED AT A RATE OF 80LBS PER ACRE IN AREAS OF ACIDIC SOILS TO ASSURE GERMINATION AND INITIAL ESTABLISHMENT. 1.2.5. MULCH: WHEAT, OAT, OR BARLEY STRAW MULCH SHALL BE APPLIED AT A RATE OF 80 LBS PER 1,000 SF. DO NOT INSTALL MULCH SO THICK THAT IT COMPLETELY COVERS THE GROUND. TOPSOIL SHOULD BE VISIBLE THROUGH THE STRAW LAYER. 2. EXECUTION AND PREPARATION: 2.1. A SOIL ANALYSIS SHOULD BE PERFORMED TO ASSESS THE FERTILITY NEEDS AND PH OF THE SOIL. ALL INSTALLATION AREAS SHOULD BE PREPARED TO AGRICULTURAL STANDARD RECOMMENDED BY THE DEPARTMENT OF AGRICULTURE WITHIN THE STATE WHERE THE WORK IS BEING PERFORMED. AGRICULTURAL LIME OR PELLETIZED LIME SHOULD BE ADDED DURING THE GROUND PREPARATION STAGE AT THE RATE RECOMMENDED ACCORDING TO SOIL ANALYSIS. 2.2. ALL WEEDS AND UNDESIRABLE PLANTS SHOULD BE REMOVED BEFORE PLANTING BY METHOD OF SPRAYING OR TILLAGE. A NON -SELECTIVE HERBICIDE CAN BE SPRAYED ONE MONTH PRIOR TO PLANTING TO KILL ALL WEEDS AND UNDESIRABLE PLANTS THAT MAY COMPETE WITH THE NEW SEEDLINGS. TILLAGE CAN BE PERFORMED AT LEAST 4 WEEKS PRIOR TO PLANTING AND AGAIN 2 WEEKS AFTER THE INITIAL TILLAGE. THE TILLAGE PROCEDURE CAN BE ADVANTAGEOUS IF LARGE AMOUNTS OF ORGANIC DEBRIS ARE PRESENT ON THE INSTALLATION AREAS. 2.3. PRIOR TO SEEDING, AREA IS TO BE TOPSOILED, FINE GRADED, AND RAKED OF ALL DEBRIS LARGER THAN 2" DIAMETER. 2.4. AREAS TO BE PLANTED SHOULD BE ROLLED WITH A CULT[ -PACKER, TURF ROLLER, OR SIMILAR DEVICE TO FIRM THE SEEDBED. THIS PROCESS HELPS ACHIEVE THE DESIRED FIRMNESS. SOIL SHOULD BE FIRMED TO 85% OF COMPACTION. 3. INSTALLATION: 3.1. STRICTLY COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS. 3.2. EQUIPMENT USED TO SPREAD SEED SHOULD HAVE SUFFICIENT CAPACITY TO HOLD AND AGITATE SEED EVENLY IN A CYCLONE OR DROP PATTERN. HYDROSEEDING MAY ALSO BE PERFORMED WITH THE ENGINEER/ARCHITECTS APPROVAL. 3.3. SEED MAY NEED TO BE APPLIED AT A HALF RATE IN ALTERNATING DIRECTIONS TO ENSURE AN EVEN COVERAGE OF SEED. 3.4. LIQUID LIME OR NEUTRA LIME DRY SHOULD BE TOPICALLY APPLIED TO AREAS WITH ACIDIC SOILS TO ASSIST THE SEED GERMINATION AND VEGETATION GROWTH DURING THE FIRST 90 DAYS. LIQUID LIME SHOULD BE APPLIED AT A RATE OF 2.5 GALLONS PER ACRE OR NEUTRA LIME DRY AT A RATE OF 80LBS PER ACRE. 3.5. FERTILIZER SHOULD BE SPREAD EVENLY OVER THE SEEDED AREAS AT THE RECOMMENDED RATE DETERMINED BY THE INITIAL SOIL ANALYSIS. IF NO SOIL ANALYSIS IS AVAILABLE EVENLY APPLY 12-20-12 STARTER FERTILIZER AT A RATE OF 250LBS PER ACRE (5.8LBS/1000 SQUARE FEET). 3.6. A ROLLED EROSION CONTROL PRODUCT CAN BE APPLIED OVER THE TOP OF SEED IN STEEP SLOPE SITUATIONS TO HELP PREVENT SEED FROM WASHING AND REINFORCE VEGETATION THROUGH ESTABLISHMENT. (FOLLOW REC PRODUCT MANUFACTURER RECOMMENDATIONS.) 4. MAINTENANCE 4.1. FREQUENT LIGHT IRRIGATION WILL NEED TO BE APPLIED TO SEEDED AREAS IF NO NATURAL RAIN EVENTS HAVE OCCURRED WITHIN 2 WEEKS OF SEEDING. AFTER SEED GERMINATION HAS OCCURRED AND PLANTS ARE VISIBLE THE FREQUENCY OF IRRIGATION CAN BE CUT BACK WITH HEAVIER APPLICATION RATES. 4.2. REPAIR ALL SEED WASHINGS AND EROSION. OWNER MAINTENANCE RESPONSIBILITIES UPON OWNER'S (OR OWNER CONTRACTOR'S) COMPLETION OF LANDSCAPING WORK, THE OWNER IS FULLY RESPONSIBLE FOR ALL FUTURE MAINTENANCE, CARE, UPKEEP, WATERING, AND TRIMMING OF ALL INSTALLED VEGETATION, PLANTS, TREE, BUSHES, SHRUBS, GRASSES, GRASS, ORNAMENTAL PLANTS AND FLOWERS, FLOWERS, GROUND COVER, AND LANDSCAPING, INCLUDING ALL LANDSCAPE ISLANDS AND SUBSOIL AREAS ADJACENT OR PART OF THE LANDSCAPED AREAS. THIS RESPONSIBILITY INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING: • TREES ADJACENT TO WALKWAYS AND AREAS OF PEDESTRIAN TRAFFIC MUST BE MAINTAINED TO ASSURE THAT ANY BRANCHES MUST BE LIMBED UP TO A CLEARANCE HEIGHT OF 7 FT. (FROM ALL PEDESTRIAN SURFACES) OR PRUNED BACK TO AVOID ANY INTERFERENCE WITH THE TYPICAL PATH OF TRAVEL. • TREES WITHIN VEHICULAR SIGHT LINES, AS ILLUSTRATED ON THE LANDSCAPE PLAN, ARE TO BE TRIMMED TO A CLEARANCE HEIGHT OF 7 FT. (FROM ALL PAVED, TRAVELED SURFACES), OR AS OTHERWISE INDICATED ON THE PLANS. • VEGETATIVE GROUND COVER, SHRUBS AND ORNAMENTAL PLANTS AND GRASSES MUST BE TRIMMED SO THAT NO PORTION OF THE PLANT EXCEEDS 30 INCHES ABOVE GRADE (OF ALL PAVED, TRAVEL SURFACES) ALONG AND WITHIN THE SIGHT LINES OF PARKING LOTS AND INGRESS -EGRESS WAYS. • FALLEN PLANT FLOWERS, FRUIT, SEEDS AND DEBRIS DROPPINGS ARE TO BE REMOVED IMMEDIATELY FROM VEHICULAR AND PEDESTRIAN TRAFFIC AREAS TO PREVENT TRIPPING, SLIPPING OR ANY OTHER HAZARDS. THESE REQUIREMENTS DO NOT AFFECT THE PLANT LIFE GUARANTEES THE LANDSCAPE CONTRACTOR IS REQUIRED TO PROVIDE. TYPICAL PERENNIAL AND GROUND COVER SPACING & LAYOUT PERENNIALIGROUND COVER PLANTING DETAIL NOT TO SCALE 0 Z IY W W ILL! U) Z F of W 0 Z D Z V7U Z W_ HUr LU> 0zLUWSJ jW zrC'J1-- WW W Fw<= 0 Wz U W � 0) > Z O (n 7 Q Q z Q z J) W zH~ H Of 0zaaUa~O Q o_ Q J W D� Of W Z z 0 Q J d Q Q. J F U W I— U) REVISIONS REV DATE COMMENT CxECKEDer 1 10/29/2021 PER ISP COMMENTS DSH RTY 2 01/21/2022 PER COUNTY COMMENTS BSC RTY 3 04/08/2022 PER COUNTY COMMENTS BSC RTY • Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DISH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: LSCP -2 PROJECT SITE PLAN DOCUMENTS FOR DIStUMU PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@,BohlerEng.com TH NICHOLAS T GEOR( r. Cert. No. 001653 19 y0 8/27/2021 k'w i PE ARG SHEET TITLE: LANDSCAPE NOTES AND DETAILS SHEET NUMBER: C-703 REVISION 3 - 04/08/2022 DESCRIPTION NOZZLE RADIUS G.P.M. P.S.I. DETAIL \ I• LANDS N/F MPB, INC. ; D. B. '15476 PG. 471 ! ' P/N. 06r00-00-00-12000 W ' E `,ZONED HC (1d/GHWAY COMMERC/AL) USE WAREHOUSE W W J z z o > '0 0 , I I S + I 1 ' ,1 1 � \ 1 \ r i r h0, r ,s v ' I ' � 1 1 I 1 1 , 1 1 , - r 1 , ` I 6 _ 1 SYMBOL MANUFACTURER MODEL NUMBER LANDS N/F W DRIP IRRIGATION SULLNAN, WILL/AM ED ARD & ✓OffN A F ' O.B. 1095 PG. 237/ PIN.- 06100-0-00-00-12-120W0 / \ ZONED.- HC (HIGHWAY COMMERCIAL USE • COMMERCIAL , RAINBIRD XFS06-18 LANDSCAPE DRIP LINE - SPACE LINES AT 18" O.C. 0.60 GPH 20 D-F / G-707 RAINBIRD PEB SERIES FLUSH VALVE - BALL VALVE IN VALVE BOX WITH T LENGTH OF TUBING G / C-707 / \ ROTORS &SPRAY HEADS \ \ 1 \ '8 � 1 ! .1 ---------------- 0 r ----------------- ---------------- // 0 pa 507 \ 5 5�1 - - r , -505- . LANDS N/F C IRLE RENTAL F 40 6 0ER 20L\--------------- ---` B. 50 PIN.- 06100-00-00-1201"0 ZONED.' HC /SEHCOWAY COMMERC/AL).'' p101 b 50 p/�\ lr l r i, * 1 r r I r 5Qh OV ® RAINBIRD 1806 SERIES POP UP SPRAY HEAD 5Q 5' 0.10 GPH 30 H-I / C-707 RAINBIRD 1806 SERIES POP UP SPRAY HEAD 5H 5' 0.20 GPH 30 H-I / C-707 RAINBIRD 1806 SERIES POP UP SPRAY HEAD 5F 5' 0.41 GPH 30 H-I / C-707 ® RAINBIRD 1806 SERIES POP UP SPRAY HEAD 80 8' 0.26 GPH 30 H-I / C-707 RAINBIRD 1806 SERIES POP UP SPRAY HEAD 8H 8' 0.52 GPH 30 H-I / C-707 . RAINBIRD 1806 SERIES POP UP SPRAY HEAD 8F 8' 1.05 GPH 30 H-I / C-707 ® RAINBIRD 1806 SERIES POP UP SPRAY HEAD tOQ 10, 0.39 GPH 30 H-I / C-707 it RAINBIRD 1806 SERIES POP UP SPRAY HEAD 10H 10, 0.79 GPH 30 H-I / C-707 RAINBIRD 1806 SERIES POP UP SPRAY HEAD 10F 10, 1.58 GPH 30 H-I / C-707 RAINBIRD 1806 SERIES POP UP SPRAY HEAD 120 12' 0.65 GPH 30 H-I / C-707 45 RAINBIRD 1806 SERIES POP UP SPRAY HEAD 12H 12' 1.30 GPH 30 H-I / C-707 - RAINBIRD 1806 SERIES POP UP SPRAY HEAD 12F 12' 2.60 GPH 30 H-I / C-707 ® RAINBIRD 1806 SERIES POP UP SPRAY HEAD 150 15' 0.92 GPH 30 H-I / C-707 ITI RAINBIRD 1806 SERIES POP UP SPRAY HEAD 15H 15, 1.85 GPH 30 H-I / C-707 . RAINBIRD 1806 SERIES POP UP SPRAY HEAD 15F 15' 3.70 GPH 30 H-I / C-707 RAINBIRD 1806 SERIES POP UP SPRAY HEAD 15EST 4 X 15 0.61 GPH 30 H-I / C-707 RAINBIRD 1806 SERIES POP UP SPRAY HEAD 15LCS 4 X 15 0.49 GPH 30 H-I / C-707 RAINBIRD 1806 SERIES POP UP SPRAY HEAD 15RCS 4 X 15 0.49 GPH 30 H-I I C-707 ® RAINBIRD 1806 SERIES POP UP SPRAY HEAD 15CST 4 X 30 1.21 GPH 30 H-I I C-707 Q RAINBIRD 1806 SERIES POP UP SPRAY HEAD 15SST 4 X 30 1.21 GPH 30 H-I I C-707 RAINBIRD 1806 SERIES POP UP SPRAY HEAD 9SST 9 X 18 1.73 GPH 30 H-I / C-707 RAINBIRD 1806 SERIES POP UP ROTARY SPRAY HEAD (45- - 270') R-VAN14 13 0.84 GPH 30 J / C-707 • RAINBIRD 1806 SERIES POP UP ROTARY SPRAY HEAD (360') R-VAN14-360 13 0.63 GPH 30 J / C-707 RAINBIRD 1806 SERIES POP UP ROTARY SPRAY HEAD (45- - 270') R-VAN18 16 1.26 GPH 30 J / C-707 • RAINBIRD 1806 SERIES POP UP ROTARY SPRAY HEAD (360') R-VAN18-360 16 1.65 GPH 30 J / C-707 RAINBIRD 1806 SERIES POP UP ROTARY SPRAY HEAD (45- - 270') R-VAN24 19 1.80 GPH 30 J / C-707 • RAINBIRD 1806 SERIES POP UP ROTARY SPRAY HEAD (360') R-VAN24-360 19 2.35 GPH 30 J / C-707 IRRIGATION ZONES . A \ --- STATION G.P.M. STATION G.P.M. STATION G.P.M. STATION G.P.M. STATION G.P.M. STATION G.P.M. i dMITEN nisicuumil \ IA,! 0 1 \ 1 \ 1 1 •/ 1 \ 1 , A 1 LANDS N/F I S S C AC005171ON5\ INC.\ 5, III I D.6 1429 rPG. 336 PIN• 06100-00�00-120Q7 I ZONED: HC (HIGHWAY COMME/�IAL) I USE SELF STQRAGE\ 1\ --505- ----------------------' , 5 I - '' 02 / ' f / / -501 v , ,' i' •'' �`\\ H ------ 9 CONTROLLER NOTE ---------_ LOCATE CONTROLLER AT LOCATION SHOWN ON PLAN. VERIFY LOCATION IN FIELD WITH OWNER'S REPRESENTATIVE. ----------------- - \ --- 3 .� 2 120 VAC POWER TO CONTROLLER LOCATION SHALL BE PROVIDED BY OTHERS. HOOK-UP OF CONTROLLER TO 120 VAC SHALL BE PERFORMED BY THE LANDSCAPE --------------' CONTRACTOR. IRRIGATION CONTRACTOR SHALL COORDINATE LOCATION OF WIRE SLEEVE PENETRATIONS THROUGH BUILDING WITH OWNER AND GENERAL ,,-'' _ -_- W/LCOHESS E(C,`, ----- ' D.& 36$2 PG r3o r CONTRACTOR. STATION RUN ORDER SHALL MATCH PLANS. __-----" ---- 704V� 06100-Z-100-120D0 '`1 IRRIGATION DISCLAIMER _ZON_EDH( GHWAY6QMMERCb9L)':`.,\\J/ 0 USE. FDEL� STAT/dN, e THIS DESIGN IS DIAGRAMMATIC. ALL PIPING VALVES AND OTHER EQUIPMENT SHOWN WITHIN PAVED AREAS OR OUT OF PROPERTY BOUNDARIES ARE FOR DESIGN -- __- ' OH - CLARIFICATION - Z CLARIFICATION ONLY, AND SHALL BE INSTALLED IN PLANTING AREAS WITHIN THE PROPERTY LINES OR LIMITS INDICATED ON PLAN. THE IRRIGATION CONTRACTOR SHALL ,,-_�-ON � y � VERIFY THE LOCATIONS OF ALL ABOVE -GRADE IRRIGATION EQUIPMENT WITH THE OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO INSTALLATION, OR IRRIGATION �8. CONTRACTOR MAY BE REQUIRED TO MOVE SUCH ITEMS AT HIS OWN COST. IRRIGATION CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL FINAL QUANTITIES PER DRAWINGS AND SPECIFICATIONS. ANY QUANTITIES PROVIDED ARE PROVIDED AS A CONVENIENCE TO THE CONTRACTOR ONLY AND SHALL NOT BE CONSIDERED ABSOLUTE. SLEEVING / WIRING NOTES: \\\ N IN ADDITION TO PROVIDING SLEEVES FOR ALL PIPING UNDER ROADWAYS AND WALKWAYS, THE IRRIGATION CONTRACTOR SHALL PROVIDE AND INSTALL SCH. 40 PVC SLEEVES FOR ALL CONTROLLER WIRES OCCURRING UNDER ALL ROADWAYS AND WALKWAYS. SLEEVES FOR CONTROLLER WIRES SHALL BE 2" DIA. AND CONTAIN NO MORE THAN 25 WIRES. `, \ 1 6.72 2 10.72 15.7 3 13.38 4 17.3 11 5 17.3 5-2 11.34 6 19.03 7 16.46 8 9 5.82 10 7.35 11 129.45 13 12.04 14 DRIP 15 5.26 16 "R. 17 18 NA 13 `so / 99 " c / I \s! 16 15 17 500- IRRIGATION LEGEND SYMBOL MANUFACTURER MODELNUMBER CONTROLLERS AND SENSORS DESCRIPTION DETAIL RAINBIRD ESP12LXME 12-STATION CONTROLLER, INTERIOR WALL MOUNT, WITH ETC-LX "ET MANAGER" CARTRIDGE A-B / C-706 Q RAINBIRD WR2-RFC RAIN/FREEZE SENSOR - MOUNT SENSOR ON EAVE OR PARAPET PER MANUFACTURER C-D / C-706 POINT OF CONNECTION 1 I U NA NA 1" WATER METER BY OTHERS ( ) NA Q FEBCO MODEL 825YA - 1" BACKFLOW PREVENTER. MOUNT IN HOT BOX INSULATED/HEATED ENCLOSURE, MODEL #HB4000-AN. COORDINATE POWER TO ENCLOSURE WITH GENERAL CONTRACTOR I� / o° 1 J• VALVES Ii v SIV ® RAINBIRD XCZ-100-PRB-COM DRIP CONTROL ZONE KIT (FLOWS UP TO 20 GPM) E / C-706 RAINBIRD PEB SERIES S S REMOTE CONTROL VALVE SIZE PER PLAN F / -7 C O6 ® RAINBIRD 33DLRC QUICK COUPLER, 3/4" G / C-706 DQ NIBCO T-FP-600A BALL VALVE, BRASS, FULL -PORT, LINE SIZE NA \ \ MAIN LINE/ LATERALS & SLEEVES N` \ w\\� 20 10 5 0 20 1"= 20' - - - ANY APPROVED PRESSURIZED PVC MAIN LINE, SCH. 40, 1-1/4" NA ANY APPROVED NON -PRESSURIZED LATERAL LINE, CL. 200 PVC, SIZE AS NOTED ON PLAN NA ANY APPROVED IRRIGATION SLEEVE, SCH. 40 PVC, MIN. TWICE SIZE OF PIPE TO BE INSERTED, ONE SLEEVE PER PIPE B-C / C-707 ANY APPROVED CONTROL WIRING SLEEVE, SCH. 40 PVC, 2" B-C / C-707 z F of w W- WZ wu-w> ;ZWW(n;W ZrC01=wpOf� ~'g wax wz J>Z0 WU)0 oW mejU) 7 m Q Q Z Q <W z U) U.] Oz<QF~�O from <J00ul�z Z 0p7w <& Q OfZ�aQ a� o J of Fo U ~ ow O zm U V) Q �s o< REVISIONS REV DATE COMMENT Dmm BY CHECKED BY 1 10/29/2021 PER ISP COMMENTS DSH RTY 2 01/21/2022 PER COUNTY BS COMMENTS RTY 3 04/08/2022 PER COUNTY BSC COMMENTS RTY Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: LSCP -2 PROJECT: SITE PLAN DOCUMENTS FOR niscu lnu PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@,BohlerEng.com �r NICHOLAS T GEO GAS r. Cert. No. 001653 h 9y� Q 8/27/2021 _ PE A - SHEET TITLE: IRRIGATION PLAN SHEET NUMBER: C-704 REVISION 3 - 04/08/2022 in 0 n U 0 3 i 6 IC N 3 F Z N Z 3 a N Z z 3 0 U GENERAL A. QUALIFICATIONS OF IRRIGATION CONTRACTOR A.A. ALL WORK SHOWN ON THESE PLANS SHALL BE PERFORMED BY A SINGLE IRRIGATION CONTRACTING FIRM SPECIALIZING IN IRRIGATION SYSTEMS. A.B. THE IRRIGATION CONTRACTOR MUST HAVE ON ITS STAFF A TEXAS LICENSED IRRIGATOR AS REGULATED BY THE TEXAS COMMISSION ON ENVIRONMENTAL QUALITY. A LICENSED IRRIGATOR OR LICENSED IRRIGATION INSTALLER SHALL BE PRESENT AT THE PROJECT SITE AT ALL TIMES AS WORK IS IN PROGRESS. THE OWNER MAY DEMAND THAT WORK STOP UNTIL THE CONTRACTOR PROVIDES FOR A LICENSED IRRIGATOR OR LICENSED IRRIGATION INSTALLER TO BE PRESENT AT THE PROJECT SITE AND SUPERVISING ALL IRRIGATION WORK. A.C. A LIST OF SUCCESSFULLY COMPLETED PROJECTS OF THIS TYPE SIZE AND NATURE MAY BE REQUESTED BY THE OWNER FOR FURTHER QUALIFICATION MEASURES. B. SCOPE OF WORK B.A. WORK COVERED BY THESE SECTIONS INCLUDES THE FURNISHING AND PAYMENT OF ALL MATERIALS, LABOR, SERVICES, EQUIPMENT, LICENSES, TAXES AND ANY OTHER ITEMS THAT ARE NECESSARY FOR THE EXECUTION, INSTALLATION AND COMPLETION OF ALL WORK, SPECIFIED HEREIN AND / OR SHOWN ON THE IRRIGATION PLANS, NOTES, AND DETAILS. B.B. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES AND REGULATIONS REQUIRED BY AUTHORITIES HAVING JURISDICTION OVER SUCH WORK, INCLUDING ALL INSPECTIONS AND PERMITS REQUIRED BY FEDERAL, STATE AND LOCAL AUTHORITIES IN SUPPLY TRANSPORTATION AND INSTALLATION OF MATERIALS. B.C. THE INTENT OF THE IRRIGATION SYSTEM IS TO PROVIDE 100 % COVERAGE OF ALL LANDSCAPE THE IRRIGATION PLAN IS GENERALLY DIAGRAMMATIC; COORDINATE IRRIGATION INSTALLATION WITH UTILITY INSTALLATIONS. ACTUAL LOCATION OF CONTROLLER, BACKFLOW DEVICE, PIPING, VALVES, SPRAY HEADS, DRIP IRRIGATION, AND RELATED EQUIPMENT MAY NEED TO BE ADJUSTED BASED ON ACTUAL SITE CONDITIONS. B.D. THE IRRIGATION DESIGN IS DIAGRAMMATIC. ALL PIPING VALVES AND OTHER EQUIPMENT SHOWN WITHIN PAVED AREAS OR OUT OF PROPERTY BOUNDARIES ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS WITHIN THE PROPERTY LINES OR LIMITS INDICATED ON THE PLAN. THE IRRIGATION CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL ABOVE -GRADE IRRIGATION EQUIPMENT WITH THE OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO INSTALLATION, OR IRRIGATION CONTRACTOR MAY BE REQUIRED TO MOVE SUCH ITEMS AT HIS OWN COST - BE. FOR CLARITY PURPOSES SOME IRRIGATION LINES AND EQUIPMENT ARE SHOWN IN HARDSCAPE AREAS WITHOUT ACCESS SLEEVES; THESE LINES SHALL BE INSTALLED IN A COMMON TRENCH OR AT THE BACK OF CURB IN LANDSCAPE AREAS. MINOR FIELD ADJUSTMENTS SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. PRODUCTS A. ALL MATERIALS SHALL BE NEW AND WITHOUT FLAWS OR DEFECTS OF ANY TYPE AND SHALL BE THE BEST OF THEIR CLASS AND KIND. ALL MATERIALS SHALL HAVE A MINIMUM GUARANTEE OF ONE YEAR AGAINST MATERIAL DEFECTS OR DEFECTIVE WORKMANSHIP. ALL MATERIALS SHALL BE OF THE BRANDS AND TYPES NOTED ON THE DRAWINGS OR AS SPECIFIED HEREIN, OR APPROVED THE CONTRACTOR MUST FIRST OBTAIN APPROVAL FROM THE IRRIGATION DESIGNER FOR AWAPPROVED EQUAL' BEFORE INSTALLING SUCH MATERIALS IN THE FIELD, OR THE CONTRACTOR MAY BE REQUIRED TO REPLACE SUCH MATERIALS AT HIS OWN COST. B. BACKFLOW PREVENTION DEVICES SHALL BE OF THE SIZE AND TYPE INDICATED ON THE DRAWINGS. INSTALL BACKFLOW PREVENTION UNITS IN ACCORDANCE WITH IRRIGATION CONSTRUCTION DETAILS AND ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. C. PIPING C.A. PRESSURE SUPPLY LINES, DOWNSTREAM OF THE POINT -OF -CONNECTION: C.A.A. SCHEDULE 40 PVC FOR ALL PIPE 1-1/2" OR LESS C.A.B. CLASS 315 PVC FOR ALL PIPE 2" TO 2-1/2" C.A.C. CLASS 200 PVC, GASKETED, FOR ALL PIPE 3" AND LARGER C..B. SLEEVING AND NON -PRESSURE LATERAL LINES (DOWNSTREAM FROM VALVES): CLASS 200 PVC C..C. FITTINGS: SCH. 40 PVC, EXCEPT AS NOTED OTHERWISE. D. VALVES AND DRIP VALVE ASSEMBLIES: TYPE AND SIZE AS NOTED ON PLANS. EACH VALVE SHALL BEAR A PRE -MANUFACTURED, NUMBERED WATERPROOF TAG BEARING A NUMBER CORRESPONDING TO ITS VALVE SEQUENCE OF OPERATION ON THE CONTROLLER. THE OPERATION SEQUENCE SHALL MATCH THAT AS SHOWN ON THE PLANS. E. QUICK COUPLERS, BALL VALVES, AND GATE VALVES: TYPE AND SIZE PER PLANS. F. VALVE BOXES: TYPE AND SIZE AS NOTED ON DETAILS. ALL VALVES BOXES SHALL BE LOCKING BOLT -DOWN TYPE, FURNISHED WITH LIDS AND BOLTS. BOXES SHALL BE OF A SIZE TO CONTAIN THE ENTIRE VALVE AND/OR VALVE ASSEMBLY. THE VALVE BOX LID SHALL HAVE THE VALVE STATION NUMBER HEAT -BRANDED INTO THE LID WITH 2" HIGH LETTERS. G. FIXED SPRAY HEADS AND ROTORS: PLASTIC BODY POP-UP, WITH A REMOVABLE PLASTIC SPRAY EXACT TYPE, MODEL, AND NOZZLE SHALL BE AS INDICATED ON PLANS. H. INTEGRAL EMITTER DRIP TUBING: TUBING MODEL AND FLOW RATE AS NOTED ON PLANS, WITH INTEGRAL EMITTERS WELDED TO THE INSIDE WALL OF THE TUBING AS AN INTEGRAL PART OF THE TUBING ASSEMBLY. I. AUTOMATIC CONTROLLER: TYPE AND MODEL PER PLANS. PROVIDE VANDAL -PROOF ENCLOSURE FOR ALL EXTERIOR INSTALLATIONS. PROVIDE LINE -VOLTAGE DISCONNECT SWITCH WITH GROUND FAULT PROTECTION. J. 24 VOLT VALVE WIRE SHALL BE A MINIMUM OF #14 GAUGE, U.F. APPROVED FOR DIRECT BURIAL, SINGLE CONDUCTOR IRRIGATION WIRE. EACH CONTROLLER SHALL HAVE A DIFFERENT COLOR STATION AND COMMON WIRE. J.A. STATION WIRE -ANY COLOR EXCEPT WHITE OR BLUE J.B. COMMON WIRE -WHITE J.C. EXTRA COMMON WIRES -BLUE K. WIRE SPLICES SHALL BE ENCASED IN A WATERPROOF COMPOUND OR GEL. ALL FIELD SPLICES SHALL BE LOCATED IN A 6 INCH ROUND VALVE BOX. L. RAIN SENSOR: TYPE AND MODEL PER PLANS. METHODS A. THIS DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, AND OTHER EQUIPMENT SHOWN WITHIN PAVED AREAS OR OUT OF PROPERTY BOUNDARIES ARE FOR DESIGN CLARIFICATION ONLY, AND SHALL BE INSTALLED IN PLANTING AREAS WITHIN THE PROPERTY LINES OR LIMITS INDICATED ON THE IRRIGATION CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL ABOVE -GRADE IRRIGATION EQUIPMENT WITH THE OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO INSTALLATION, OR IRRIGATION CONTRACTOR MAY BE REQUIRED TO MOVE SUCH ITEMS AT HIS OWN ENSURE FIELD COORDINATION IS MADE EARLY ON IN THE CONSTRUCTION PHASE SO PLACEMENT LOCATION IS CORRECT. B. THE IRRIGATION CONTRACTOR SHALL MEET WITH THE OWNER'S REPRESENTATIVE PRIOR TO COMMENCEMENT OF WORK, AND SHALL OBTAIN ALL ENGINEERING, LANDSCAPE, AND OTHER APPLICABLE PLANS & DOCUMENTS. THE CONTRACTOR SHALL THOROUGHLY REVIEW THE PLANS AND REPORT ANY CONFLICTS OR DISCREPANCIES TO THE LANDSCAPE ARCHITECT AND OWNER'S REPRESENTATIVE IMMEDIATELY. C. THE IRRIGATION CONTRACTOR SHALL NOT WILFULLY INSTALL THE IRRIGATION SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS, GRADES OR DIMENSIONS EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEEERING. SUCH OBSTRUCTIONS OR DIFFERENCES SHALL BE BROUGHT TO THE ATTENTION OF THE IRRIGATION DESIGNER. IN THE EVENT THAT THIS NOTIFICATION IS NOT PERFORMED, THE IRRIGATION CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS AND NECESSARY COSTS. D. SEE UTILITY PLANS FOR IRRIGATION POINTS OF CONNECTION (TAP) AND DOMESTIC WATER SUPPLY. E. THE IRRIGATION CONTRACTOR SHALL PAY ANY AND ALL FEES ASSOCIATED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM. F. AT LEAST SEVEN DAYS BEFORE BEGINNING WORK, CONFIRM THE STATIC WATER PRESSURE IS AT LEAST 60 PSI. IF STATIC WATER PRESSURE IS LESS THAN STATED, DO NOT PROCEED WITHOUT FIRST NOTIFYING THE IRRIGATION DESIGNER AND OWNER IN WRITING, AND OBTAINING SUBSEQUENT DIRECTION FOR CORRECTIONAL MEASURES. SHOULD THE IRRIGATION CONTRACTOR CHOOSE TO BEGIN THE INSTALLATION WITHOUT SUCH NOTIFICATION, THE IRRIGATION CONTRACTOR WILL ASSUME THE RESPONSIBILITY FOR ALL COSTS INCURRED TO ENSURE THE SYSTEM IS WORKING PROPERLY. NO CHANGE ORDERS WILL BE AUTHORIZED IN SUCH CIRCUMSTANCES. G. THE IRRIGATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITY LINES (WATER, SEWER, ELECTRICAL, TELEPHONE, GAS, CABLE, TELEVISION, ETC.) PRIOR TO THE START OF ANY WORK. THE CONTRACTOR SHALL BE FAMILIAR WITH ALL GRADE DIFFERENCES, LOCATIONS OF ALLS, STRUCTURES AND UTILITIES - IT. COORDINATE WITH THE OWNER THE PROPOSED LOCATIONS OF THE AUTOMATIC CONTROLLER AND ANY REQUIRED SLEEVES THROUGH THE BUILDING FOR CONTROL WIRES. I. TRENCHING NEAR EXISTING TREES: I.A. CONTRACTOR SHALL NOT DISTURB ROOTS 1-1/2" AND LARGER IN DIAMETER WITHIN THE CRITICAL ROOT ZONE (CRZ) OF EXISTING TREES, AND SHALL EXERCISE ALL POSSIBLE CARE AND PRECAUTIONS TO AVOID INJURY TO TREE ROOTS, TRUNKS, AND BRANCHES. THE CRZ IS DEFINED AS A CIRCULAR AREA EXTENDING OUTWARD FROM THE TREE TRUNK, WITH A RADIUS EQUAL TO V FOR EVERY 1" OF TRUNK DIAMETER -AT -BREAST -HEIGHT (4.5' ABOVE THE AVERAGE GRADE AT THE TRUNK). I.B. ALL EXCAVATION WITHIN THE CRZ SHALL BE PERFORMED USING HAND TOOLS. NO MACHINE EXCAVATION OR TRENCHING OF ANY KIND SHALL BE ALLOWED WITHIN THE CRZ. I.C. ALTER ALIGNMENT OF PIPE TO AVOID TREE ROOTS 1-1/2" AND LARGER IN DIAMETER. WHERE TREE ROOTS 1-1/2" AND LARGER IN DIAMETER ARE ENCOUNTERED IN THE FIELD, TUNNEL UNDER SUCH ROOTS. WRAP EXPOSED ROOTS WITH SEVERAL LAYERS OF BURLAP AND KEEP MOIST. CLOSE ALL TRENCHES WITHIN THE CANOPY DRIP LINES WITHIN 24 HOURS. I.D. ALL SEVERED ROOTS SHALL BE HAND PRUNED WITH SHARP TOOLS AND ALLOWED TO AIR-DRY. DO NOT USE ANY SORT OF SEALERS OR WOUND PAINTS. J. ALL BACKFILL MATERIAL SHALL BE SUBJECT TO APPROVAL BY THE OWNER. BACKFILL MATERIAL SHALL BE FREE FROM RUBBISH, ROCK, LARGE STONES, BRUSH, SOD, FROZEN MATERIAL OR OTHER UNSUITABLE SUBSTANCES THAT MAY DAMAGE PIPE DURING THE BACKFILLING OPERATIONS. IN THE EVENT THAT THE MATERIAL FROM THE EXCAVATION OR TRENCHING IS FOUND TO BE UNSUITABLE FOR USE IN BACKFILL, IT SHALL BE REMOVED FROM THE SITE AND PROPERLY AND LEGALLY DISPOSED OF BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. THE CONTRACTOR SHALL THEN PURCHASE AND AND FURNISH SUITABLE BACKFILL MATERIAL CONSISTING OF EARTH, LOAM, SANDY CLAY, SAND OR OTHER APPROVED MATERIALS FREE OF DEBRIS. K. BACKFLOW INSTALLATION: CONTRACTOR SHALL MAKE CONNECTIONS TO EXISTING WATER SOURCES AT LOCATION SHOWN ON PLANS AND AS APPROVED BY THE OWNER, AND SHALL MAKE ANY MINOR CHANGES IN LOCATION AS MAY BE NECESSARY DUE TO ACTUAL SITE CONDITIONS. BACKFLOW HEIGHT SHALL BE AS PER LOCAL CODES AND IRRIGATION DETAILS. INSTALL A BRASS BALL VALVE IMMEDIATELY UPSTREAM OF THE BACKFLOW DEVICE TO SERVE AS AN ISOLATION VALVE. L. PIPING: L.A. PIPE SIZE SHALL CONFORM TO THOSE SHOWN ON THE DRAWINGS. NO SUBSTITUTIONS OF SMALLER PIPE SIZES SHALL BE PERMITTED, BUT SUBSTITUTIONS FOR LARGER SIZES MAY BE APPROVED. L.B. MAINLINE PIPE AND WIRES SHALL BE INSTALLED WITH A MINIMUM COVER OF 18 INCHES.LATERAL PIPE SHALL BE INSTALLED WITH A MINIMUM COVER OF 12 INCHES. L.C. ASSEMBLE ALL THREADED FITTINGS WITH TEFLON TAPE, WHICH SHALL BE APPLIED TO MALE THREADS ONLY. L.D. ALL SOLVENT -WELD CONNECTIONS SHALL BE MADE WITH APPROVED SOLVENT -WELD PRIMER AND GLUE. L.E. PIPE SHALL BE INSTALLED WITH A MINIMUM OF 4" HORIZONTAL CLEARANCE FROM ANY OTHER PIPE AND 2" VERTICAL CLEARANCE FROM ANY PIPES THAT CROSS OVER OR UNDER. M. VALVES SHALL BE INSTALLED PER MANUFACTURER'S DIRECTIONS AND THE IRRIGATION DETAILS. EACH VALVE SHALL BEAR A PRE-PRINTED WATERPROOF TAG BEARING THE APPROPRIATE CONTROLLER STATION NUMBER. N. VALVE BOXES SHALL BE INSTALLED FLUSH WITH THE GRADE, WITH CLEAN PEA GRAVEL LOCATED BELOW THE VALVE AS NOTED ON THE DETAILS. EACH VALVE BOX COVER SHALL BE HEAT -BRANDED WITH THE CONTROLLER STATION NUMBER- 0. DRIP IRRIGATION EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S DIRECTIONS AND THE IRRIGATION DETAILS. O.A. SUBSURFACE DRIP LINES SHALL BE BURIED NO MORE THAN 2" BELOW FINISH GRADE. O.B. DRIP LINES MOUNTED ON GRADE SHALL BE LOCATED BENEATH LANDSCAPE FABRIC, AND SECURED IN PLACE WITH WIRE STAPLES AT A MAXIMUM OF 48" ON CENTER. P. SPRAY, ROTOR, AND BUBBLER HEADS: P.A. ALL SPRAY AND ROTOR HEAD LOCATIONS SHALL BE STAKED, FLAGGED AND/OR OTHERWISE CLEARLY MARKED ON THE GROUND PRIOR TO INSTALLATION. SPRINKLER HEAD STAKING SHALL BE INSPECTED AND APPROVED BY THE OWNER'S REPRESENTATIVE BEFORE INSTALLATION. P.B. ALL SPRAY HEADS SHALL BE CONNECTED WITH A 12 INCH MINIMUM LENGTH OF112 INCH FLEX PVC. THE FLEX PVC SHALL BE SOLVENT WELDED TO SCHEDULE 40 PVC FITTINGS WITH WELD -ON #795 SOLVENT AND #P-70 PRIMER. ALL ROTORS SHALL BE CONNECTED TO LATERAL LINES WITH PRE -MANUFACTURED SWING JOINTS. ALL ROTOR, SPRAY AND BUBBLER HEADS SHALL BE SET PERPENDICULAR AND FLUSH TO FINISH GRADE AND WITH A CLEARANCE OF FOUR INCHES (MINIMUM) FROM THE EDGE OF ANY BUILDINGS, WALLS, BOULDERS, AND HARDSCAPE, UNLESS OTHERWISE SPECIFIED. P.C. ALL ROTOR, SPRAY AND BUBBLER HEADS AND VALVES SHALL BE FLUSHED AND ADJUSTED FOR OPTIMUM COVERAGE WITH MINIMUM OVERSPRAY ON WALKS, STREETS, WALLS, ETC. Q. AUTOMATIC CONTROLLER: Q.A. INSTALL THE CONTROLLER AT THE LOCATION INDICATED BY THE OWNER. INSTALL CONTROLLER WITH A BACKUP BATTERY AS RECOMMENDED BY THE MANUFACTURER. Q.B. THE IRRIGATION CONTRACTOR SHALL COORDINATE 120 V.A.C. ELECTRICAL POWER TO CONTROLLER AND DEDICATE ONE (1) 20-AMP BREAKER FOR EACH CONTROLLER. IT SHALL BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO MAKE THE FINAL HOOK-UP FROM THE ELECTRICAL SOURCE TO THE CONTROLLER UNIT ONLY. Q.C. ALL VALVE CONTROL WIRE SHALL BE AWG 14 TYPE UF, 600 VOLT TEST, DIRECT BURIAL. NO SPLICES SHALL BE ALLOWED EXCEPT AT VALVES AND CONTROLLER. WHERE SPLICES MAY BE NECESSARY DUE TO EXCESSIVELY LONG WIRE RUNS, THE CONTRACTOR SHALL MAKE ALL SPLICES IN 6" ROUND VALVE BOXES WITH 3M'S "DBY-DIRECT BURIAL SPLICE KIT'. THE CONTRACTOR SHALL LABEL ALL WIRES WITH WATERPROOF TAGS AND MARKERS AT ALL SPLICES AND VALVE MANIFOLDS, AND SHALL LEAVE A 24" COIL OF EXCESS WIRE AT EACH CONNECTION. Q.D. PROVIDE #10 COMMON WIRE, DIRECT BURIAL, TO ALL REMOTE CONTROL VALVES. Q.E. CONNECT ALL DIRECT BURIAL WIRES TO VALVES USING 3M'S "DBY-DIRECT BURIAL SPLICE KIT' (UNLESS OTHERWISE SPECIFIED). Q.F. PROVIDE THREE ADDITIONAL IRRIGATION CONTROL WIRES ALONG EACH BRANCH OF MAINLINE FOR FUTURE EXPANSION. STUB ADDITIONAL CONTROL WIRES INTO BACK OF IRRIGATION CONTROLLERS. Q.G. THE IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL CONTROL WIRE SLEEVES AND PIPE SLEEVES UNDER PAVED AREAS PRIOR TO PAVING - SEE SLEEVING NOTES. R. INSTALL THE RAIN SENSOR IN THE VICINITY OF THE CONTROLLER, AND COORDINATE LOCATION WITH THE OWNER. IT IS THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO ENSURE THE RAIN SENSOR IS PLACED IN A LOCATION WHERE IT CAN RECEIVE ADEQUATE RAINFALL WITHOUT OBSTRUCTIONS. IF IT IS PLACED IN AN INADEQUATE LOCATION, THE IRRIGATION CONTRACTOR MAY BE REQUIRED TO RELOCATE IT AT NO ADDITIONAL COST TO THE OWNER. S. ALL IRRIGATION EQUIPMENT NOT OTHERWISE DETAILED OR SPECIFIED SHALL BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. T. QUALITY CONTROL T.A. PERFORM COVERAGE TESTS AFTER SPRINKLER SYSTEM IS COMPLETED BUT PRIOR TO ANY PLANTING AND PERFORM TESTING IN THE PRESENCE OF THE IRRIGATION DESIGNER AND THE CONSTRUCTION MANAGER. T.B. TEST SYSTEM TO ASSURE THAT ALL LAWN AND PLANTING AREAS ARE WATERED COMPLETELY AND UNIFORMLY. T.C. MAKE ALL NECESSARY ADJUSTMENTS TO PROVIDE COMPLETE COVERAGE, INCLUDING REALIGNMENT OF HEADS AND REPLACEMENT OF NOZZLES. U. CLEAN UP U.A. DURING IRRIGATION EXCAVATION AND INSTALLATION, KEEP ALL PAVEMENT CLEAN AND ALL WORK AREAS IN A NEAT, ORDERLY CONDITION. U.B. DISPOSED LEGALLY OF ALL EXCAVATED MATERIALS OFF THE PROJECT SITE. V. INSPECTION AND ACCEPTANCE V.A. UPON COMPLETION OF THE WORK THE IRRIGATION CONTRACTOR SHALL PROVIDE THE SITE CLEAN FREE OF DEBRIS AND TRASH, AND SUITABLE FOR USE AS INTENDED. THE IRRIGATION CONTRACTOR SHALL THEN REQUEST AN INSPECTION BY THE OWNER TO DETERMINE FINAL ACCEPTABILITY. V.B. WHEN THE INSPECTED WORK DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS THE CONTRACTOR SHALL REPLACE AND/OR REPAIR THE REJECTED WORK TO THE OWNER'S SATISFACTION WITHIN 24 HOURS. V.C. THE MAINTENANCE PERIOD WILL NOT COMMENCE UNTIL THE WORK HAS BEEN RE -INSPECTED BY THE OWNER AND FOUND TO BE ACCEPTABLE. AT THAT TIME, A WRITTEN NOTICE OF FINAL ACCEPTANCE WILL BE ISSUED BY THE OWNER, AND THE MAINTENANCE AND GUARANTEE PERIODS WILL COMMENCE. V.D. CONTROLLER CHART: THE IRRIGATION CONTRACTOR SHALL PROVIDE A 8 1/2" X 11" COLOR -CODED, LAMINATED COPY OF THE IRRIGATION LAYOUT AND PLACE IT IN THE CONTROLLER'S COVER. THE CONTROLLER CHART SHALL CLEARLY DELINEATE THE AREAS COVERED BY EACH VALVE, USING A SEPARATE COLOR FOR EACH ZONE. V.E. TURN THE FOLLOWING ITEMS IN TO THE OWNER UPON COMPLETION OF THE INSTALLATION: V.E.A. QUICK COUPLER KEYS (2) V.E.B. CONTROLLER MANUAL (1) V.E.C. CONTROLLER KEYS (2) V.E.D. A MINIMUM OF (2) COPIES OF RECORD DRAWINGS. A RECORD DRAWING IS A RECORD OF ALL CHANGES THAT OCCURRED IN THE FIELD AND THAT ARE DOCUMENTED THROUGH CHANGE ORDERS, ADDENDA, OR CONTRACTOR/CONSULTANT DRAWING MARKUPS. W. REFER TO THE PLANTING SPECIFICATIONS FOR ADDITIONAL CONDITIONS OF FINAL ACCEPTANCE AND START OF THE MAINTENANCE PERIOD. X. WARRANTY X.A. THE IRRIGATION SYSTEM SUPPLIED AND INSTALLED SHALL BE WARRANTED (LABOR AND MATERIALS) TO REMAIN OPERATIONAL FOR A PERIOD OF 12 MONTHS AFTER THE DATE OF FINAL ACCEPTANCE. DURING THIS PERIOD, THE CONTRACTOR SHALL ALSO REPAIR ANY SETTLEMENT OF THE IRRIGATION TRENCHES. X.B. BY THE END OF THE WARRANTY PERIOD, ANY IRRIGATION PART THAT IS EITHER NON -OPERATIONAL OR THAT IS OPERATING BELOW STANDARDS AS DETERMINED BY THE OWNER, SHALL BE REMOVED FROM THE SITE AND SHALL BE REPLACED. REPLACEMENTS SHALL BE OF THE SAME KIND AS SPECIFIED IN THE IRRIGATION LEGEND, AND SHALL BE INSTALLED AS ORIGINALLY SPECIFIED. X.C. IRRIGATION PARTS DAMAGED OR IMPAIRED DUE TO ACTS OF GOD, VANDALISM, AND/OR THE OWNER'S IMPROPER MAINTENANCE SHALL NOT BE COVERED BY THIS WARRANTY. 01 FINISH GRADE/TOP OF MULCH (2) QUICK COUPLER VALVE: BUCKNER MODEL QCV Q3 VALVE BOX WITH COVER ® PVC SCH 80 NIPPLE (AS REQD LENGTH) 3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL © BRICK (1 OF 2) (7) PVC SCH 40 ELL 8 PVC SCH 40 TEE OR ELL 9 PVC MAINLINE PIPE PVC SCH 40 ELL 11 2" X 2" REDWOOD STAKE WITH STAINLESS STEEL GEAR CLAMPS OR EQUIVALENT SUPPORT SYSTEM NOTE: FURNISH FUIINGS AND PIPING TO BE SIZED PER THE NOMINAL QUICK COUPLING VALVE INLET SIZE VALVE - QUICK COUPLER C-706 SCALE: NOT TO SCALE Backfiow prevention device.(See the Bress ball valve. irrigation plans for make and model). Install the device per the local water Threaded galvanized purveyor's standards and specifications. nipple. Galvanized piney degree (90°) elbow. Galvanized nipple. Ev Galvanized union. N ii 8 Wrap 20 mil tape 4" thick Concrete pad, 1" above finished o twice al grade. See back8ow, cage detail. galvanizxeded ppipip e under . finished grade and ^:' :r through me concrete. e. Galvanized nipple. Ifflil Galvanized coupling. Flow Note: 1- All assembly parts (threaded nipples, fittings, etc.) shall be galvanized or brass per local codes and requirements. Sch. 80 PVC male 2- Galvanized nipple shall extend 12" past the edge of the concrete footing. adapter. Concrete thrust 3- Sch. 80 PVC male adapter shall be used in connection from galvanize to the mainline. blocks required on backfiow devices 2.5" 4- Backfiow prevention device shall be located as close as possible to the landscape meter. and larger. 5- Backfiow prevention device shall be located in planting area unless approved by Owner's Representative. 6- See detail for back6ow cage installation. 7- All back6ow prevention devices shall have freeze blanket included upon installation. 8- All galvanized connections shall to be made using pipe thread sealant. All Sch. 80 PVC to galvanized connections to be made using tefion tape. SCALE: NOT TO SCALE ESP-LXME RED WHITE ROJO BLANCO 24 VAC SENSOR ■ MV O COMMON BLACK GREEN NEGRO VERDE ORemove jumper wire, if present. Retire el cable puente, si to haV. 0 Connect WR2 wires. Conecte los cables del sensor WR2. CONTROLLER/RAIN SENSOR WR2 - ESP-LXME WIRING DIAGRAM SCALE: NO I 10 SCALE O FINISH GRADE/TOP OF MULCH O VALVE BOX WITH COVER: O RAIN BIRD VB—STD 30—INCH LINEAR LENGTH OF O WIRE, COILED WATERPROOF CONNECTION: O RAIN BIRD DB SERIES 1—INCH BALL VALVE (INCLUDED IN XCZ—PRB-100—COM KIT) © ID TAG O REMOTE CONTROL VALVE: RAIN BIRD PESB (INCLUCED IN XCZ—PRB-100—COM KIT) O PRESSURE REGULATING QUICK CHECK BASKET FILTER: RAIN BIRD PRB—QKCHK-100 (INCLUDED IN O XCZ—PRB-100—COM KIT) PVC SCH 40 FEMALE ADAPTOR 10 LATERAL PIPE 11 PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) 12 PVC SCH 40 ELL 13 PVC SCH 80 NIPPLE (2—INCH LENGTH, HIDDEN) AND PVC SCH 40 ELL GPVCSCH G 40 TEE OR ELL 15 MAINLINE PIPE 16 3—INCH MINIMUM DEPTH OF 3/4—INCH WASHED GRAVEL 17 PVC SCH 80 NIPPLE, CLOSE (INCLUDED IN XCZ—PRB-100—COM KIT) E VALVE - XCZ-100-PRB-COM DRIP ZONE KIT IN SQUARE VALVE BOX C-706 SCALE: NOT TO SCALE vru-vr__ - rr=o OGTtN SCALE: NOT TO SCALE O30-INCH LINEAR LENGTH OF WIRE, COILED O WATERPROOF CONNECTION RAIN BIRD SPLICE-1 (1 OF 2) O ID TAG: RAIN BIRD VID SERIES O REMOTE CONTROL VALVE: RAIN BIRD PESB-PRS-D WITH NP-HAN O VALVE BOX WITH COVER: RAIN BIRD VB-STD O FINISH GRADE/TOP OF MULCH (DPVC SCH 80 NIPPLE (CLOSE) ® PVC SCH 40 ELL O PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) 10 BRICK (1 OF 4) 11 PVC MAINLINE PIPE 12 SCH 80 NIPPLE (2-INCH LENGTH, HIDDEN) AND SCH 40 ELL 13 PVC SCH 40 TEE OR ELL 14 PVC SCH 40 MALE ADAPTER 15 PVC LATERAL PIPE 16 3.0-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL w RzM SEE WIRING DETAIL CONTROLLER - WE SCALE: NOT TO SCALE INDOOR WALL O RAIN BIRD CONTROLLER: RAIN BIRD ESP-4Mi INDOOR WALL MOUNT O1—INCH PVC SCH 40 CONDUIT AND FITTINGS FOR VALVE WIRES O RAIN BIRD WR2 WIRELESS SENSOR CONTROLLER INTERFACE r8 rITayy ® CABLE HARNESS FOR CONTROLLER vlU INTERFACE (30" MAXIMUM) ® O GROUND WIRE TO �® GROUNDING GRID 6 6 120 VAC 60 HZ O EXTERNAL PLUG—IN TRANSFORMER NOTES: 1. FOR BEST PERFORMANCE, THE CONTROLLER INTERFACE SHOULD BE INSTALLED AT LEAST FIVE FEEL ABOVE THE GROUND. 2. IT IS RECOMMENDED THAT THE CONTROLLER INTERFACE BE INSTALLED AWAY FROM SOURCES OF ELECTRICAL INTERFERENCE (SUCH AS TRANSFORMERS, GENERATORS, PUMPS, FANS, ELECTRICAL METER BOXES) AND METAL OBJECTS TO MAXIMIZE COMMUNICATION RANGE. r_____________� I I I I RED� I I OR GREEN I BLACK OR I I WIRES ® WHITE I I TO HERE WIRES I I TO HERE I I Z 2 (0 > N U I I � I I WIRING DETAIL L MOUNT INTERIOR WR2 SERIES RAIN SENSOR INTERFACE OUTDOOR WALL NOTES: 1. FOR BEST PERFORMANCE, THE CONTROLLER INTERFACE SHOULD BE INSTALLED AT LEAST FIVE FEEr ABOVE THE GROUND. 2. IT IS RECOMMENDED THAT THE CONTROLLER INTERFACE BE INSTALLED AWAY FROM SOURCES OF ELECTRICAL INTERFERENCE (SUCH AS TRANSFORMERS, GENERATORS, PUMPS, FANS, ELECTRICAL METER BOXES) AND METAL OBJECTS TO MAXIMIZE COMMUNICATION RANGE. O RAIN BIRD CONTROLLER: RAIN BIRD ESP-4M OUTDOOR WALL MOUNT O 1—INCH PVC SCH 40 CONDUIT AND FITTINGS FOR VALVE WIRES O RAIN BIRD WR2 WIRELESS SENSOR CONTROLLER INTERFACE O CABLE HARNESS FOR CONTROLLER INTERFACE (30" MAXIMUM) O GROUND WIRE TO GROUNDING GRID O JUNCTION BOX (DI/2—INCH PVC SCH 40 CONDUIT TO POWER SUPPLY 1 I I I RED� I OR GREEN I I BLACK OR I I WIRES ® WHITE I I TO HERE WIRES I I TO HERE Z i 7 > w U I I � I I WIRING ___________J DETAIL B CONTROLLER - WALL MOUNT EXTERIOR WR2 SERIES RAIN SENSOR INTERFACE C-706 SCALE: NOT TO SCALE A-W _zoaoIiLLYAELWG SCALE: NOT TO SCALE O1 RAIN BIRD CONTROLLER WITH WR2 CONTROLLER INTERFACE O RAIN BIRD WR2 SENSOR RECOMMENDED MOUNTING SITE O SITES NOT RECOMMENDED FOR MOUNTING WR2 SENSOR NOTES: 1. SENSOR MAY BE MOUNTED ON FENCE, FENCE POST OR ON GUTTER OF HOUSE. 2. SENSOR SHOULD NOT BE MOUNTED UNDER TREES, IN AREAS AFFECTED BY SPRINKLER SYSTEM OR UNDER LAVE OF HOUSE. 0 Z_ EE W W W U) Z F of W Z W H W Ur KWW(n jW ZrCDHQofU) FWax WZ (n � > Z U W O Z U) Q Q Z Q Z (n�WZFH Of 0Zof O Y H Q U a Z J 00 Z) W Z z aQ > aJ of U W I-_ U) REVISIONS REV DATE COMMENT 1 10/29/2021 PER ISP COMMENTS 2 01/21/2022 PER COUNTY COMMENTS ]BSC 3 04/OS/2022 PER COUNTY COMMENTS • Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: LSCP -2 PROJECT SITE PLAN DOCUMENTS FOR DISICUMQ PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA(BohlerEng.com TH 747 NICHOLAS T GEOR( Cert. No. 001653 Pb 8/27/2021 PE ARG SHEET TITLE: IRRIGATION NOTES AND DETAILS SHEET NUMBER: C-705 REVISION 3 - 04/08/2022 �LU (DW-FLUSH HEADER EE 3 53a 2 PRE -INSTALLED BARB RTTNG BackflOw Prevention device. (Sae ifd9ati00 WCiO legend for make and model). W3 I 2 4 DRIOFLUSH POINT WITH PVC G4P OR OPTIONAL- PVC SALL VALVE ZW LU 6 BU4 PERIMETER OF AREA 0 Z 0 O Ba ke an cage. (See irrigation legend for Z � Z LU i OPE2!-4'R DRIPLLNE PIPE TO BE INSTALLED footink VConcrete ove make and model). lZ W 0 (� W2-4 FROM PERIMETER OF AREA footing d grade Q U (n U S PVC SUPPLY PIPE FROM RAIN BIRD CONTROL (9 Z W W > LU I O ZONE KIT (SIZED TO MEET LATERAL ROW finished grade. Z } ( H W of U) 1 2 3 4 5 fi 5 I INSET A OT OFOSU POLY HEADER H lJJ 0 LU Z z"-4" I B Lock box. D of Z of U Q �1 I OB RAIN BIRD XFS SERIES DRIPUNE (TYPICAL) U) of Qofm Q F I I Finished grade. I 7 15 14 2 Oy MALE ADAPTER INSERT Z U) W Q Z O FINISH GRADE I " Z H INISH GRADE/TOP OF MULCH z 15 10 STAINLESS STEEL. OETKER OR MURRAY CLAMP O Q a Q _ Of ? 22 PVC DRIP MANIFOLD PIPE 6 I 11 OPERATION INDICATOR U Q U OL OP —UP SPRAY SPRINKLER: /��i L J ��,, - - 1©PVCASCHIAD CCAAPDEL OPERAND Z J 0 Q Z) w RAIN BIRD 1806—SAM O PVC 1" X -Y4' TRUE UNION BALL VALVE _ - 3 PVC SCH 40 EWL VA VE FLOWS J OfWV U) a INSET of Q WITH RAIN BIRD ROTARY NOZZLE J 44 EASY FIT MALE X BARB ADAPTER: INBLT A J T I Z SUN BIRD %F SERIES BLANK TUBING ; of 'VC SCH 80 NIPPLE RAIN BIRD XFF—MA-075 e a ANEW BARB %BARB INSERT TEE SECTION O U (LENGTH AS REQUIRED) 5 SUB -SURFACE DRIPLINE: I 15 RUN BIRD XFF-TEE (TYPICAL) RAIN BIRD XF SERIES BLANK TUBING i I B 16 PVC SCH 40 ELL (TPICAL) � LU 'VC SCH 40 ELL ® 12-INCH VALVE BOX WITH COVER: I ©PVC SCH a RISER PIPE n ��O1Wfie' RAIN BIRD VB—STD VC SCH 40 STREET ELL 3-INCH MINIMUM DEPTH OF i a ID 8 XF SERIES TE-AWN S N ES DS-O50) 4" hick Backlim cage. INCFT c I I � REFER TO RAIN BIRD DRIPLINE DESIGN GUIDE mrlcrete footing. $'4 WASHED GRAVEL L__� FOR PROPER SPACING 'VC SCH 40 TEE OR ELL °0 °° ° °° ° pO O8 BRICK (1 OF 2) -l--- - _I e i :: Concrete foobng. VC LATERAL PIPE po - Q 0� Z066M,� °��02°Mpo% 3 1 2 3 INSET pooOpO°O %%2S000 Y' oO�pOo I 6"ryp :'.•.. SPRAY HEAD - 1806 ROTARY NOZZLE SWING JOINT CONNECTING SCALE: NU I I U SCALE z 3 a F Z N W N 3 o- N Z z 3 K 9 a U IPLINE - XFS SUB SURFACE FLUSH POINT WITH BALL VALVE 1O FINISH GRADE/TOP OF MULCH O POP—UP SPRAY SPRINKLER: RAIN BIRD 1806—SI—PRS WITH 1800 VPC WITH RAIN BIRD ROTARY NOZZLE O PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) O PVC SCH 40 ELL O PVC SCH 40 STREET ELL 6O PVC SCH 40 TEE OR ELL 7O PVC LATERAL PIPE NOTE: SIDE INLET CONNECTION SHOULD NOT BE USED IN FREEZING CLIMATES. SPRAY HEAD - 1806 SPRAY HEAD SIDE INLET SWING JOINT CONNECTING_ C-707 SCALE: NOT TO SCALE SPRAY HEAD HEAD - 180HEAD - 180 707 SCALE: NOT TO SCALE INISH GRADE/TOP OF MULCH 'OP —UP SPRAY SPRINKLER: RAIN BIRD 1806—SAM—PRS WITH 1800 VPC WITH RAIN BIRD ROTARY NOZZLE 'VC SCH 80 NIPPLE (LENGTH AS REQUIRED) 'VC SCH 40 ELL 'VC SCH 40 STREET ELL 'VC SCH 40 TEE OR ELL 'VC LATERAL PIPE NOTES: 1. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOILPE, TYPLANT MATERIALS AND CHANGES IN ELEVATION. SEE INSIALIATION SPECIFICATIONS ON RAIN BIRD WEB SITE (MMW.RAINBIRD.COM) FOR SUGGESTED SPACING. 2. LENGTH OF LONGEST DRIPUNE LATERAL SHOULD NOT EXCEED THE MAXIMUM SPACING SHOWN IN THE ACCOMPANYING TABLE. XFS Oripllne Maximum Lalerel Lengths (Feet) InletP.a ,I IT ST 18'8patlry 2P STPW, NOminel Fl.(yph) B.B O.B N.1.1Flow(gpIv 02 0.9 NvM"Fb (gM1) O2 09 15 Zr3 155 314 250 424 322 zB 31B 1Be 353 204 Sae no 3D 413 350 Sea 414 40 395 255 495 4W 852 474 SO 417 285 us 420 720 400 BD 4so 200 506 155 780 514 DRIPLINE - XFS SUB SURFACE CENTER FEED LAYOUT SCALE: NO I 10 SCALE .\ rM ® i.I4■■,. SPA @ d '-1 111�ii� :u 0 NOTES: 1. DISTANCE BETWEEN LATERAL. ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE, PLANT MATERIALS AND CHANGES IN ELEVATION. SEE INSTALLATION SPECIFICATIONS ON BAN BIRD WEB SITE (WWW.RAINBIRD.COM) FOR SUGGESTED SPACING. 2. LENGTH OF LONGEST DRIPUNE LATERAL SHOULD NOT EXCEED THE MAXIMUM SPACING SHOWN IN THE ACCOMPANYING TABLE. QOF-RUSH HEADER O2 PRE -INSTALLED BARB FITTING OFIMBSH ALl DINT WITH PVC GAP OR OPTIONAL PVC VADI4OPERIMEIER OF AREA OPERIMETER DRIPLINE PIPE TO BE INSTALLED 2•-4' FROM PERIMETER OF AREA ©RALN BIRD XFS SERIES DRIPUNE (TYPICAL) SUPPLY HEADER O PVC DRIP MMIIFOO FROM RAIN BIRD CONTROL FLOWZONE VALVE KIT (SUED TO MEET OBLATERAL P SUN 40 ILLL (TYPICAL) 10 PVC SCH 40 RISER PIPE 11 MALE ADAPTER INSERT 12 STAINLESS STEEL, OETIKER OR MURRAY CWAP 13 PVC SOH 40 CAP 14 PVC SCH 40 BAIL VALVE 15 OPERATION INDICATOR RAIN BIRD MODEL OPERIND 18 XF SERIES TIE -DOWN STAKES DDS-D50) REFER TO RAIN BIRD DRIPUNE DESIGN GUIDE FOR PROPER SPACING XFS Dripline Maximum Lateral Lerlgtho (Feet) InIMPreec pal 17spadn9 xominal Flm(Wh) D.8 08 18-SpatlW Nomlrel Flom(gA) 02 02 I 2CSpWng Na4re Fb (gph) os 0.9 15 219 155 314 25D 42A 322 A 9 953 2B4 500 9B0 30 0 413 35D 508 414 40 T,.-. 5 445 402 652 474 w 529 420 720 49e m 598 465 790 514 E DRIPLINE - XFS SUB SURFACE END FEED LAYOUT C-707 SCALE: NOT TO SCALE PT �� Q NOTES: 1. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE. PLANT MATERIALS AND CHANGES IN ELEVATION. SEE INSTALI SPECIFICATIONS ON RAIN BIRD WEB SITE (WBW.RAINBIRD.COM) FOR SUGGESTED SPACING. 2. LENGTH OF LONGEST DRIPUNE LATERAL SHOULD NOT EXCEED THE MAXIMUM SPACING SHOWN IN THE ACCOMPANYING TABLE 3. PLACE TE DOWN STAKES EVERY THREE FEET IN SAND, FOUR FEET IN LOAM. MD TIME FEET IN CLAY. 4. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR ELBOWS, USE TIE -DOWN STAKES ON EACH LEG OF TIE CHANGE OF DIRECTION. vRlrulV� -nrooL SCALE: NOT TO SCALE OAF -SUPPLY HEADER O2 PRE-INSTALIED BARB FITTING 03 PVC DRIP MANIFOLD MGM RAIN BIRD CONTI ZONE VALVE KIT (SIZED TO MEET LATERAL ROW DEMAND) ®RAIN BIRD XFS SERIES DRIPUNE (TYPICAL) OPERIMETER OF AREA ©PERIMETER DRIPUNE PIPE TO BE INSTALLED 2"-4' FROM PERIMETER OF AREA OFLUSH POINT (TYPICAL) - SEE RAIN BIRD XFD DETAILS FOR FLUSH POINT INSTALLATION ©BARB X BARB INSERT TEE OR ELL,' RAIN BIRD XFF-TEE OR RAIN BIRD XFF-ELHDW (TYPICAL) O9 PVC RISER PIPE 10 PVC SUPPLY MANIFOLD 11 PVC SCH 40 SLEEVE PIPE SIZED TWICE THE SIZE OF MANIFOLD PIPE SIZE 12 PVC SCH 40 TEE OR ELL (TYPICAL) 13 PAVEMENT AND CURB 14 MALE ADAPTER INSERT 18 SIAINLESS STEEL OEIIKER OR MURRAY CIMP 8OPERATION ERATION INDICATOR RAIN BIRD MODEL: OPERIND 1 PVC SCH 90 CAR 18 XF SERIES TE-DOWN STAKES (ADS-050) REFER TO RAIN BIRD DRIPUNE DESIGN GUIDE FOR PROPER SPACING XFS Dripline Maximum Lateral Lerlgthe (Feat) INMP..,l 12'apatln, 18-SPm1ro 2C sp ln9 Nomlm Fla (ph) D.9 02 Rminai Flaw(gIm OA 0.9 NpNMIFb (,,Tm 0.8 02 15 273 155 319 250 624 322 20 318 169 359 294 500 %0 3D MIT 230 413 350 3N 414 40 305 255 445 4W 952 474 w 417 M 529 42D 70 499 80 4B0 290 596 456 TOO 514 PLAN VIEW Notes: 1- Install backflow cage per manufacturer's specifications and recommendations. 2- See backfiow prevention device detail for reference. 2- Look box shall be located above concrete footing 3- Contractor shall provide a lock as approved by the Owner's Representative. BACKFLOW PREVENTER - TYPICAL BACKFLOW COVER INSTALLATION SCALE: NU I 10 SCALE Finished grade. Direct burial low voltage control wires. NOTES: 1- See irrigation legend for mainline and lateral line pipe size and type. 2- Direct burial Control wires shall be installed in Sch. 40 PVC electrical Conduit W required. 3- 2-wire irrigation wire shall be installed in Sch. 40 PVC electrical ConduR. 4. Delectable locator tape shall be located six inches (S") above the entire mainline Con. Pavement. Detectable locator tape. line (mainline). B TRENCHING - IRRIGATION TRENCHING UNDER GRADE C-707 SCALE: NOT TO SCALE L.I. 0 ]4'-.. .. .. •'-'l ••..4 1. i..�. •,''..�,•"�• _ __ _ Clean backfill, 95% relative compaction under paving or per civil engineer's plans. Control wires, sleeve under paving. Install adjacent to pressurized mainline. Bundle shall be no more than 50% of pipe diameter Mainline, sleeve under paving to be two times the diameter of the pressurized mainline pipe. Non -pressurized line, sleeve under paving to be two times the diameter of the lateral line. Notes: 1- See irrigation legend for mainline size and type. 2- All sleeves shall be Sch. 40 PVC pipe. 3- All sleeves shall extend 12" beyond the edge of pavement. 4- End of sleeves shall be located with a Wooden stake or PVC pipe. Locators shall Con Continuously from the end of the sleeve to finished grade. I RCIVL.A rlI1VV - IRRN SCALE: NOT TO SCALE REVISIONS REV DATE COMMENT 1 10/29/2021 PER ISP COMMENTS 2 01/21/2022 PER COUNTY COMMENTS ]SC 3 04/08/2022 PER COUNTY COMMENTS 1 Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: LSCP -2 PROJECT SITE PLAN DOCUMENTS FOR DISC®C�7aQ PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@,BohlerEng.com 01TN � rw �//�)/ /� NICHOLAS T GEOR( Cert. No. 001653 8/27/2021 PE ARG SHEET TITLE: IRRIGATION NOTES AND DETAILS SHEET NUMBER: C-706 REVISION 3 - 04/08/2022 NEW from Dekorra Products BACKFLOW ENCLOSURES !^r l DEKORRA irable polyethylene construction to -piece design with easy lift-off access .SE Standard 1060 approval on all Pee classifications of protection lilt -in double -locking hasp f sect -resistant ventilation media MODEL 301-Gi ,,,MA a,aMaM rna.n inea•,a FOR OUTDOOR INSTALLATIONS Our insulated and uninsulated enclosures are designed primarily for the backflow, market and fit W-2" backflow assemblies and pressure vacuum breakers. Available in three configurations: 1 Dekorra box and base only, , 2 Dekorra backflow box and base with an 9 insulated pouch providing R-13 insulation; or 3) Dekorra backflow, box and base with insulation and self-regulating heat source. 4) Optional Cage View- design allows for easy visual inspection and vandal protection. Choose from two natural tones —Green Turf or Brown Granite. Job Name Contractor Job Location Approval Engineer Contractor's P.O. Number Approval Representative Model Options Specifications Dekorra Backflow Enclosures incorporate features to provide for positive drainage, security, and accessibility for monitoring, testing, repairing and replacing components. The enclosure provides freeze protection, freeze retardant or non -freeze protection of the components inside. ASSE Classes » CLASS [ (CI) -Freeze protection. Dekorra Enclosures Class I and I-V shall have a minimum thermal resistance value of eight and a positive means of heat. Dekorra Backflow enclosures have been designed and constructed to maintain a minimum internal temperature of 40OF. is CLASS II (0) - Freeze retardant. Dekorra Enclosures Class 11 and II-V shall have a minimum thermal resistance value of eight. Dekorra Backflow enclosures have been designed and Constructed to be installed in minimum external temperatures of 3YE » CLASS III (0) - Non -freeze protection. Dekorra Enclosures Class III and III-V are designed and constructed to provide system security for components when freezing Molxi 3olaGcv temperatures are not a consideration. BF-VR543/11 MODEL 301 MODEL 302 21.0 ------ I... 8.5 335 �16.50 y.—.I ASSE CLASSIFICATIONS: CLASS In (C3) (non -insulated) CLASS n (C2) (insulated) CLASS I (C7) (insulated & heated) MODEL 301 I WNgh 1516sW.dth:16.5', seight26.5• units per ® Model 301-BG-C3PC U6 56803 33012 9 Model 301-BG-C2 UPC 6 56803 23012 2 4A Model 301-BG-C1 Baooet Sot-aGc3 UPC 6 5680313012 5 "Model 301 ASI UPC 6 56803 330112 Model 301-GT-CZ UPC 6 56803 230115 Model 301 GT-C1 MODEL 3o1crc3 UPC 656803130118 4AModel 301 CageView"' Model 301 GT-CV UPC 6 56803 630113 Model 301-BG-CV UPC 6 56803 63012 0 MOM BM4W..CV This enclosurek base has a solid floor for mounting a pump. Model 321 Dimenslem: 33.5%x 16.5•W x 26.5'11 Model 321 GT UPC 6 56803 03011 1 Model 321-BG UPC 6 56803 03012 8 Sou 9.7 27.s II•� 4e.o .� 7.0 �. MODEL 302 I Weight: 25 os, 5 units peruse.27.5• MODEL 302-Brr03 COLOR OPTIONS: Choose Brown Granite (BG) or Green Turf (Gin No STANDARD OPTIONAL Foam Inserts Metal Vents Model 701-FV Model 701-MV Foam inserts for Optional metal grate ventilation are included venneforaddnional with each enclosure. security. Hardware is included with each enclosure for anchoring to a concrete pad. Stakes are also included for situations where no concrete pad is required. Model 302-BG-C3 UPC 6 56803 33022 8 Model 302-BG-C2 UPC 6 56803 230221 Model 302-BG-Cl UPC 6 5680313022 4 Model 302-GT-C3 UPC 6 56803 330211 Model 302-GT-C2 UPC 6 56803 230214 Model 302-GY-Cl UPC 6 56803130217 Model 302 CageView'" Model 302-GT-CV UPC 6 56803 630212 Model 302-BG-CV UPC 6 56803 63022 9 This enclosure's base has a solid floor for mounting a pump. Model 322 Dlmensiam: 48'L x 17"W x 27.5"H Model 322-GT UPC 6 56803 030210 Model 322-BG UPC 6 56803 03022 7 lkorraproducts,comhf1DEKoRRAEmail: info@dekorraproducts.com Oil �aV www.dekorraproducts.com Call Toll Free: 888.635.8585 MADE IN THE USA srcva>e°or.,*nlNs RAI* kBIR0. WR2 Series Wireless Rain/Freeze Sensors Superior Signal Reliability and Ease of Use The Rain Bird Wireless Rain Sensor is designed Electrical Specifications for24VAC residential and commercial irrigation .Application: suitable foruse with 24VAC systems. This high -quality product saves water controllers(with or without pump start and extends irrigation system e autor*• 9 � life master valve) callysensing precipitation and interrupting irl . Electrical rating suitable for use with up to gation during rain and low temperature events. six 24VAC NA solenoids plus an additional r Programming 09 Pe 9 - rammin logic can suspend irrigation pump master valve or m start that does not using" uick Shut Off"feature or the theQ exceed 53VA amount of rainfall exceeds the rainfall set point •Controller Interface wire: 30"(76 cm) length of Ukewise,the Wireless Rain/ Freeze Sensorwill #22 gauge(0.64 men) UV resistant extension suspend irrigation when the system reaches a wire _ a programmed low temperature set point •UL, cUL, CE, C-Tick and WEEE certifications Features & Benefits • FCC approved spread spectrum 2 way radio Is Enhanced antenna array provides transceivers with FCC Class B approvals �•-� • Signal transmission distance of 7W Line of superior signal reliability that overcomesg most lineof-line-of-sight obstructions uctions Sight T ■ Sensor signal strength indicator enables -Battery life: four or more years under normal one person set up, reducing installation operating conditions time • 6 KV surge / lighting protection WR2 Sensor Assembly Is Convenient adjustment and monitoring Mechanical Properties •Sensor Length: 513"(14.7cm) of min orfreeze settings at the controller interface -Adjustable rainfall settings from 1/8"-1/2" • Attachment Bracket Length: 4.6'(11.7 cm) in Simple battery replacement requiring no (3 -13 mm) • Distance between Mounting Holes: 4.25" tools or need to disassemble sensor •Adjustable low temperature settings from (10.8Lm) 3rF -41"F (0.5' - 5Y) • Horizontal displacement (bracket +fixed ball ■ Highly intuitive icon -driven controller •Threeinigation modesroselect Programmed, arm):55"(14.0cm) interface simplifies programming Suspend Irrigation for 72 hours, Override Replacement or Spam Parts ■ Easy to install, self -leveling sensor bracket sensor for 72 hours • WR2 Battery- #651009S mounts to flat surfaces or min gutters ."Quick Shut Off"suspends active irrigation • WR2 Disk Assembly - #63781 OS ■ Antennas concealed within the units for cycle within approximately two minutes greater visual appeal and product . High-grade, UV resistant polymer units resist robustness harmful environmental affects in 'Quick Shut Off" interrupts active irrigation cycle during a min event Dimensions • • ' WR2 Controller Interface WR2 - RC Models •Width: 3.1"(7.9 cm) Product Models Description •Length:6JY(172 cm) Model North Amerlca(916 MHz) WR2-RC Rain Combo WR2 Re Rain combo • Depth: 17(43 cm) RF❑ Rain/Freeze Combo WR2-RFC Rain/Freeze Combo • Distance between Mounting Holes: RS: Rain sensor only WR2-RS Rain Sensor Only 625"(15.9 [m) RFS: Rain/Freeze Sensor Onlylish Rain/rreeasController WR2-RFS Rain/Freeze Sensor Only Interface Onty WR2-RFI Rain/Freeze Controller International (868 MHz) Interface Only RC-B68: Rain Combo RFC-868: Rain/Freeze Combo Specifications The wireless min or min /freeze sensor shall employ an electro-mechaniwl actuating mechanism designed to cause a circuit interrupt B programmable low temperature or rainfall set points are satisfied. Satisfied set points cause the device to temporarily suspend the irrigation controller schedule. As environmental condi- tions return to a state that no longer satisfy the low temperature or rainfall set points, the con- trollers normal irrigation schedule is resumed. The sensor shall be wired to normally closed (N.C.) controllers - in series with the valve com- mon, oraltemately, wires shall be inserted into the appropriate controller sensorterminal ports. The device shall be of rugged construction to withstand the elements, including exposure to sunlight and precipitation. Antennas shall be concealed within the sensor and controller interface to improve aesthetics and product robustness The device shall be used with 24VAC controllers and shall be ofsufficient capacity to be used with a maximum of six 24VAC NA Solenoids plus an additional master valve or pump start that does not exceed 53VA The wireless min sensor shall incorporate a provision that allows the Installer to select from several rainfall or low temperature settings that can be programmed through the use of icons on a controller interface A sensor LED shall com- municate signal strength during the installation process The Rain Bird Rain or Rain / Freeze Sensor shall be manufactured Rain Bird Co ration by rPo Glendora, California. Rain Bird Corporation 6991 E. Southpoint Road Tucson, AZ 85756 Phone: (520) 741-6100 Fax (520) 741-6522 Rain Bird Technical Services (800) RAINBIRD (1-800-724-6247) (U.S. and Canada) ORegh dT■demadcorxaln BWCorma O ZxD9Raln BIN Corporation 10N9 Versatile Mounting Bracket Rugged self leveling brack maintains rain sensor orientation Battery replacement requires no tools RA/N�B/RD. Rain Bird Corporation 970 West Sierra Madre Avenue Azusa, CA 91702 Phone: (626) 812-3400 Far. (626) 812-3411 Specification Hotline 800-458-3005 (U.S. and Canada) + a ill �a.Ar�ee.,Pa Robustinternal antennas for superior aesthetics Rain Bird International, Inc. 1000 West Sierra Madre Azusa, CA 91702 Phone: (626) 963-9311 Fax: (626) 852-7343 wivnNrminIpInL dm RA/N4B/RV ESP -Li Controller Tech Spec ESP-LX Series Controllers !p, - ;a The popular Rain Bird ESP-LX Series commercial Controller Features - controllers have been enhanced to provide addi- 'Large LCD display with easy, ronavigate Softkey .■ tiomlteatares and station apaciry.The ESP-LXME userinterface . Enhanced Controller provides flow sensing and •Hot-swappable modules, no need to power management with modular station wpaciryfrom down the controllerto add/remove modules �•I - modulesareavailable in 4, SE,and1 , Dynamic station numbering eliminates station 12-station 8-,and l2-staUon models. numbering gaps e, Applications • Weather Sensor input With override switch Master valvetpump start circuit The ESP-LXME provides flexible features and • 6user-selectable languages modular o Uons that make the controller ideal P Yea P 9 memory • Non -Volatile 100- r ro ram ( ) fora wide variety of applications including light- • Standard 10W surge protection commercial, commercial, and industrial irrigation • From panel is removable and programmable Electrical Specifications systems. Modularoptionsindudemodularstatim under battery power Input required: 120VACt 10%6OHz opacity, flow sensing, metal case and pedestal, Water Management Features (International models: 230VAC t 10%, 50Hz or ETC Manager Smart Cartridge, and NCC Network 61 Australian Models: 240VAC t 10% 50Hz) Control Communication Cartridge&Thme options Optional Flow Smart Module -with Learn Flow Output: 265VAC 19A arefield installed and Cana upgrade and enhance P9 utility and flow usage tDmlizer tY 9e Powerback-up: L'rthiummincell battery the ESP-LXME at an time in the future. Y FloWari protection for high low flow P g maintains time and date while nonvolatile conditions with userdefined reactions memory maintainsthe programming Easy to Use FloManager' manages hydraulic demand, Multi -valve Capacity. Maximum five 24VAC, The ESPAXME Controller utilizes the Rain Bird ESP making full use of available water to shorten 7VA solenoid valves simultaneous operation Extra -Simple Programming user interface. The dial, total watering time including the master valve, maximum two switches, and batons interlace which Rain Bird SimulStations"amprogmmmabletoalim up solenoid valves per station first introduced in the early 1990s is easy to learn to5stationsto operate at the same time Windows by program plus Manual MV Certifications and use and has beconleastandard controllerWater Water Window UL,CU4CE, CSA,C-Trck,FCC Part 15 interface forthe irrigation industry. The large LCD Cycle+Soak'"by station display incorporates softkey text labels for the but- • Rain Delay Dimensions niunctions mtherthan dedicated buttons. 365-Da Calendar Off Y Day Width:1432in. (36p an) Multiple language support allows the end -user • Programmable Station Delay by program Height12.69 in.(32,2 on) or maintenance personnel to interface with the • Normally Open a Closed Master Valve Depth: 550 In.(14,0an) controller in their primary language. User select- programmable by station able languages include English, Spanish, French, • Weather Sensor programmable by station to German, Italian, and Portuguese. Date, time, and preventorpausewatering unit formats are also user configurable. Program Seasonal Adjust • Global Monthly Seasonal Adjust Easy to Install Diagnostic Features e The ESP-LXME Controller has a spacious case and Alarm light with external case lens quick -connect terminals making installation fast Electronic diagnostic Circuit breaker ESP-LXME ESPLXMSM4 and easy. Multiple size wiring knockouts are pro- Progmmsumrogramary review videdonthe bottom and backside ofthe case to • Variabletestprogmm adapt roawide variety of wiring applications.The Base Controller without Station Modules doorandfrontpanel areremovable sothecasecan RASTER"'stadonviring test Flow Smart Module ESPLXMSM4: ESP-BLxMF 4Station Module be easily mourned to the wall. Operating Specifications 8-station base ESPLXMSMB: • Station timing: 0 min to 12 has 8-Station Module Controller Hardware . Seasonal Adjust O%to 300%(16 him maximum ESPLXM5M12. • Plastic, locking, UV resistantwalhmount case station min time) 12-Station Module • Optional painted steel and stainless steel cases • 4independent progmms(ABCO) Basecontrollervoth FSM-LXME and pedestals P ABCD programs can overlap p 9 P Flow Smart Module • 8-,or 12-stationsbase unit expandable to 48 • 8 start times per Frogman ESPtation base 12-station base Flow SmartModules Stations with 4,8-,&12-Station Modules Program Day Cycles ro eS include days dthe FSM-LXME Flow Smart • Flow Smart Module'"factory installed orfield week Odd,Odd3l, Even,&Cyclical dates Module upgmdable • Manual station, program, test program RA/N�B/RD Specifications daycyde.(Custom, Every Odd,Odd31,&Cyclia0. Module features shall include a FloWatch Leant Flow The ESP-LXME Controller shall beofa hybrid type that Days setto Permanent Day Off shall override the Utilitywhichlearnsthenormalflowrateofeachsm- combineselectro-mechanialandmivcelectroniccir- wrmalrepmtingxheduleandnotwateronthe flon. Each time the station mm FloWatch compares cuitry capable of fully automatic or manual operation. specified day(s) ofthe week The controller shall also the currentreaFtime flow rate to the learned rate The controller shall be housed in a walFmountable, have a Calendar Day Off feature allowing the user to and takes user defined actions Ifhigh flow, low Bari weather -resistant plastic cabinet with a key -locking select up to 5 dates up to 365-days in the future when ornoflow is detected. FloWatdh shall automatically cabinet door suitable for either indoor or outdoor the controller shall not start programs The controller determinethelocationoftheflowproblemandiw- The installation. The controllershall hawtheabiliryro shall incorporate attain Delayfeaturealloving the late the problem by turning of the affected station or be programmed andopershalated inanyonedsix userto setthe numberddaysthe controller should mastervalve. FloWatch shall be compatible with both languages:English, Spanish, French, German, Italian, remain off behxeamomadally returning rothe auto normally dosed and open mastervahres.AManual &Portuguese. The display shall show programming mode MasterValveWamrWirdows shall be provided to options and operating instructions in the chosen The controller shall have CydeRsoakwatermanage- coordinate day time manual watering with the flow senpng.ofthewerWlndowsshawatll erprogmmma- language without aheringthe programming or ment software which is apableofoperating each star cue daysdtbeweekand manual watering additional operation information. don for a maximum cycle time and a minimum soak flow rate. The controller shall have a base station capacity of Lane to reduce water mn-off. The maximum cycle 8 or 12 stations as well as Expansion slots capable time shall not extended by Seasonal Adjustment. The controller shall have an alarm indicator light on of receiving station modules of4,8, or 12 stationsto The controllershall incorporate a FloManager the front panel visible through the outer door with the doordosed and locked. The alarm light shall create a controller opacity of up to 48 stations All feature providing real-dmeflow, power, and station prompt the user roselect the alarm softkeyto review stations shall have the apabilitydindependently management. FloManager shall managethe number the aWrm condlUon(s). obeying or ignoring the weather sensor as well as of stations operating at any poi at in time based on using cur not using the mastervalve. Stationtiming water source opacity, station flow rate, number of Thecontroikr shall be mmpadble with the ETC-LX ET shall befrom 0 minutesto 12 hours. The controller valves per station, user -defined simultaneous stations Manager Cartridge which upgrades the controller to a shall havea Seasonal Adjustment by program which per program and for the controller. FloManager shall Smart controller. A weather service signal received by adjusts the station run time from 0to3o0%in 1% incorporate the ability to providesmdon priorities to the cartridge shall automatiallya4ustthe individual increments. The controller shall also have a Monthly determine the order in which stations shall operate. controller program day cycles and station min times to Seasonal Adjustmentoi 300% by month. Station The controller shall ignore the station number and applythe minimum arroulltofwater required based timing with Seasonal Adjustment shall be from l Instead operate the highest priority stations first and on the current plant water requirements, second to 16 hours. the lower priority stations last when Flohlanager The controller shall becompaliblewidltheIQ- Platform Tbecontroller shall itave 4 separate and independent is enabled. FloManagershall bean option thatis disabled by default andthe controllershall operate utilizing NCC NeNrorkCommuniationCartridges The programs which an have differemstarttimes,start zones inorder number,started the NCC Camidge shall providemmmuniradonw»hthe IQ day Yd Pro9 c and station Nn Umes Each ramCentral es,Cerhtm umberfszone ending lowest zone smroirri irrigate endin with 9a 9 u[erando other II d the controllers P ry shall have upto8 start times perdayforatotal of 32 the highest numberzone. g comxnuniationopdons (Direct ConnectCable, Phone, Possible start times Perd y.The4 Pro9rams shall be GPRS/Cellular,EthemetWhFi, Radi0.ard lCX4et allowed to overlap operation based on user defined The controller shall offer Water Windows for each CommunicadonCable). ThelQ Platform shall settings which control the number of simultaneous program. This function sets theallowed startand prwideremotemnputawmroldtheconodler stations per program and total for the controller stop time wherewa[ering is allowed. Ifthewatering prwidirgautomaflcormanualpogmmacgLGmhen6. The controller shall allow up to 5 valves to operate cannot be completed by the time theWaterWndow simultaneously per program and total forthe controk closes, the stationswith remaining con dmeare Thecontroller shall offeran optional metal cabinet let including the mastervahnspump start circuit The paused and watering automatically resumes when and pedestal. controller shall have an electronic, diagnostic circuit theWaterWndow opens the next time. The controller shall beas manufactured by Rain Bid breaker that shall sense a station with an electrical overload or short circuit and shall bypass thatstation The controllershall offera Flow Smart Module option Corporation. and continue to rate all other stations, operate which adds flow sensingfunctionality. The Flow Smart Module sensor input shall accepts direct The controller shall have a 365-daycalendar with input from a flow sensor with no flow scaling device Permanent Day Off feature that allows a day(s) tithe required. weekto beturned off on any user selected program Rain Bird Corporation 6991 E. Southpoint Road Tucson, AZ 85756 Phone: (520) 741-6100 Fax (520) 741-6522 Rain BbdTedhdcal Services (BOD) RAINBIRD (1-800-724-6247) (US. and Canada) 0 Registered Trademark of Rain Bird Corporation 02015 Rain Bird Corporation 10/15 Rain Bird Corporation 970 West Sierra Madre Avenue Azusa, CA 91702 Phone: (626) 812-3400 Fax (626) 812-3411 Specification Hotline BOD-458-3005 (U.S. and Canada) Rain Bird International, Inc. 1000 West Sierra Madre Ave. Azusa, CA 91702 Phone. (626) 963-9311 Fax (626) 852-7343 The Intelligent Use of Water' www.ninblyd.com The new ESP-LXME Controller supports up to 48 stations. Your irrigation challenges come in all shapes and sizes. That's why the new ESP-LXM 12-Station Module delivers the flexibility you need to control sites ranging from large residential all the way to large commercial. Just snap the module into place and expand to up to 48 stations in 4-,8- or 12-station increments. With a single ESP-LXME Controller, you can now tackle almost any high -end job. No-nonsense installation. Modular, plug -and -play design makes adding stations a snap. Install 4-,8- or 12-station modules 1n any order within the cabinet. Dynamic Station Numbering orders stations in the correct sequence, preventing unwanted numbering gaps. Extra Simple Programming. Get up and running faster thanks to the proven ESP controller interface, featuring easy -to -follow prompts and a large, easy -to -read display. Easy customization. Whether the job is large or small, only pay for the number of stations you need with your choice of 4-,8- and now 12-station modules. To learn more about the new ESP-LXM 12-Station Module, talk to your Rain Bird sales representative. RAY* kBIRD. Model Description Mounting Equipment ESPLXMSM8 8-Station Module LXMM Metal Cabinet ESPLXMSM12 12-Station Module LXMMPED Metal Pedestal Number of each component to order # of Stations Required Specify As: ESP-LXM-SM4 ESP-LXM-SM8 ESP-LXM-SM12 8 ESP-8LMME 0 0 0 12 ESP-12LXME 1 0 0 16 ESP-16LXME 0 1 0 20 ESP-20LXME 1 1 0 24 ESP-24LXME 0 2 0 28 ESP-28LXME 1 2 0 32 ESP-32LXME 0 3 0 36 ESP-36LXME 0 2 1 40 ESP-40LXME 0 1 2 44 ESP-44LXME 0 0 3 48 ESP-48LXME 0 0 4 Station Numbering Labels and instructions (shown below) are included with each 12-Station Module Individual carton (6 modules per master carton). — ' 71*57 r (mW. •„ I 'A'.f.e'.p AN A, as aei ai .x ANaz M � j RIs - I® Hai o A-^C 3 $ ° o , • tie m_ o o ss --. ------ e ] C? u " 'ie I ei ' ii ' •• I - a a 2 rt 0 N M « Y lx1')b It k LU 2 O m W � F W i w�LDW> �zwwNWW w¢x�wz >z0W XnO i Q¢Z U)2LUZ FH )ZO Q< n Q CiU)2a J 0 0� W Z Z CL Q > d J REVISIONS REV DATE COMMENT 1 10/29/2021 PER ISP COMMENTS 2 01/21/2022PER COUNTY COMMENTS JR—T 3 04/08/2022 PER TY C0101i TS B Know what§ below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AN DIOR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: LSCP -2 PROJECT SITE PLAN DOCUMENTS FORalsiraM m1�Ir PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND VIRGINIA 23146 Phone: 804 893-8200 VA@BohlerEng.com �,pLTH OF G� f,r�a NICHOLAS T GEO GAS Cert. No. 001653 7?'1 8/27/2021 U scq PE ARG�� SHEET TITLE: IRRIGATION �1/N *BIRD® NOTES AND D40030BEO DETAILS SHEET NUMBER D BACKFLOW PREVENTER - ENCLOSURE CUT SHEET C WEATHER SENSOR - WR2 CUT SHEET B CONTROLLER - ESP-LXME TECH SHEET A CONTROLLER - ESP-LXME CUT SHEET C-707 708 SCALE: NOT TO SCALE C-708 SCALE: NOT TO SCALE C-708 SCALE: NOT TO SCALE C-708 SCALE: NOT TO SCALE REVISION 3 - 04/08/2022 _1 w Z a rn z z 0 Q RA/**B/RD. PEB and PESB Series Valves Designed to Outperform. Engineered to Outlast. Pressure surges? Effluent water? Clogging • FlowwithPRS-D:5to200gpm debris. No problem. FEBand PESB Series P 1.14 to 45.40 m3fi• 192 to 7571/m ( ) valves offer longlife and efficient trouble- • Tem ratumbi to150°F 66° Pe P ( Q free performance -even under harsh condi- tions.Constructed ofheavy-duty,glass-filled Electrical Specifications nylon, these valves resist clogging. And the Power. 24VAC 50/60 Hz (cycles/sec) PESB model features a patented scrubber to solenoid actively fight dirt, debris and particles. Inrush current: OAl A (9.84 VA) at 60 Hz • Holding current: 0.14A(3.41 at6OHz Features Coil resistance: 30-39 Ohms • Body constructed of durable glass- Compatible with ESP-LXD decoders filled nylon for long life and heavy-duty performance at 200 psi It 3.80 bar) pressure • Stainless steel studs molded into the body. Bonnet can be attached and removed ilillill more easily without damaging threads Flow 0-PEB 10150-PEB 200-PEB GPM 1" 11h" Y • One-piece solenoid design with captured 0.25 03- - plunger and spring for easy servicing 0s to - - Prevents loss of parts during field service 1 13 - - 5 1.7 • External bleed protects the solenoid ports 10 1.8 - from debris when system is flushed - 20 2.9 3.95.6 • Internal bleed operates the valve without 30 10. 3b 40 3s allowing water into the valve box;allows 50 15.6 3b 43 pressure regulator to be adjusted without 75 - 5.4 45 turning on the valve at the controller first 125 - 14.6 81 • Low flow operating capability(0.25 gpm; 150 - 21.2 11.8 0.06 m3/h; 1.21/m) for a wide range of 175 - - 155 200 195 a lication&Forflows below m (1.14 m3A1; 1921/m) or any Xeriganon• application, install Rain Bird Yfilter upstream Flow Flow 100-PEB 150-PEB 200-PEB • Slow dosing to prevent water hammer and ma/h an Vm 2.5 an 306 5.1 cm subsequent system damage 03 -B 5 0.09 - - • PESB only: Scrubber scrapes its stainless _0.6_ 10 0.10 - - steel screen deantobreak down grit and 12 3 20 o:fz - so 0.3s - - plant material. Prevents debris build-u P 6 100 0.32 016 - and clogging 9 150 0.6B 014 - 12 200 - 026 033 Optionsseparately) (orderse arately) 15 18 250 033 300 0.42 032 032 • Accommodates optional, field installed 21 24 350 - 057 400 0.74 034 0.41 PRS-D pressure regulating module to 27 450 - 0.92 051 ensure optimum sprinkler performance 30 500 - 1.14 0.64 • Optional purpleflowmntmil handles for 36 5t3s 600 77 o0.90 non-potablewaterappliations 39 650 - - 1.04 - PEB-NP-HAN1(19 42 700 - - 1.18 - PEB-NP-HAN2 (1 Wand 2) 45 757 - - 134 • Accepts latching solenoid for use with 'w'°' i)Ias wXres arewtthfl"wamNVrdNman Rain Bird battery -operated controllers up D pRS.Dmodukretpnmended/wonflawmrgex to 150 psi (1035 bar) R.dwnaanaaR•n, NI.SRI Operating Range (2-NmaiMremmmmEsnowmksntrove berhore,wrNe (219,Nmabmharto,ed„re14MA1sn`wmu Ivan . „o.4a•ndda..5gpmn.Mrr�,,91,vm,.aalna„rem,,,me"d,me"r • Pressure.20to200psi(I.38tol3.80bar) 'w`"`°mfilw°`ep'ma"ta 'c°*`dngbdm,•meaap,mgm. • F ow:025to200gpm(O.06to45AOry f,* 30 Far lbws below ldgpn r}S7mh 379Um) Rave Bhd,xammends the Trowrontrol:ranberrnreads.nlnorwlrrrm:wmmerwyopmpalab•,. 12 to 757 Vm) Specifications Tech Spec PESB Cutaway Dimensions Sam Height LWWM 9ndth 100 VA'(165an) C(102crl r(101an) 150 8"(203an) 6'(15.2 m) 6'(15.2an) 2DO 8`(20.3 ant 6"(15.2an) 6"(151an) Not The PRS-0 option adds 2' Is, i on) M wit height Models • 1 OOPEB and 1 OOPESB 1" (26/34) • 15OPEB and 15OPESB 1'Ih- (40/49) • 200PEBancI2O0PESB 2" 150/60) BSP threadsavana6k spedrywhen ordering. 100 - PEB - PRS-D rr ra'aaaaa sire Model Optional Feature 1011'DW34) PEB PRS Dial:pressure 15U 1 W(40/49) PE58:scrobber regulatingmodule 200: 20 (50/60) model (mustbeordered s ravel 1 ePa Y Nam above andpRS-Dialmodulenoun bewdeedsepe- d ri Far,mnil.S apFlicadons, it is necessary or specify NpT"rniforra type. R.aia�BiRv The electric remote control valve shall be a Optional Feature Specification normally closed 24VAC 50/60 Hz(cycles/sec) PRS-D Pressure Regulating Module: solenoid actuated globe pattern design.The valve pressure rating shall not be less than 100PEB-PRS-D 100PE5B-PRS-D 200 psi(13.80 bar). The valve shall have the tSaPEB-PRS-D i5oPE56-PRS-D following characteristics(circle one): 20OPEB-PRS-D 20OPESB-PRS-D Flow rate: gpm m3/h I/m Whensoindicatedte the design, the ," Pressure loss not to exceed: psi bar alvh and 2"electric remote control plastic valves shall have pressure regulating module The valve body shall be constructed of (PRS-D) capable of regulating outlet pressure heavy-duty glass -filled UV -resistant nylon and between 15 and 100 psi (t3 psi) (1.04 and 6.90 have stainless steel studs and flange nuts; bar(a0.21 bar)). diaphragm shall be of nylon reinforced n1 iIs The PRS-D module shall have an adjusting rubber, knob for setting pressure and Schrader valve The valve shall have both internal and external connection for monitoring pressure. -The manual open/dose control (internal and pressure shall be adjustable from the PRS-D external bleed) to manually open and close when the valve is internally manually bled or the valve without electrically energizing electrically activated. the solenoid.The valve's internal bleed shall prevent flooding of the valve box Non -Potable Flow Control Handle* The valve shall house a fully -encapsulated, PEB-NP-HANI-Fits 1" one-piece solenoid. The solenoid shall haw a PEB-NP-HAN2 - Fits 1'h"and 2" Captured plunger with a removable retainer When so indicated on the design, the valve for easy servicing and a leverage handle for shall have a purple flow control handle to easy turning. This 24VAC 50/60 Hz solenoid indicate to the user that non -potable water shall open with 19.6 VAC minimum at 200 psi is being used. -There shall be no difference (13SO bar). At 24VAC, average Inrush current between the black and purple handles except shall not exceed 0.41 amps. Average holding for the color. current shall not exceed 0.28 amps. Vo.BodoNen mePFse-Rreda;med,+nmwAtcard The valve shall have a brass flow control stem convenient kiufor rawrmeemanner application. PleaseseeTech for accurate manualr regulation and/or Shut-off e9 '�D3733BB fRaInBird camichrwsnwwwmin lArd.corn /ormareinformation. of outlet flow. The valve must open or close in less than 1 minute at 200 psi (13.80 bar), and less than 30 seconds at 20 psi (138 bar). The PESB valve shall have a self-cleaning stainless steel screen designed for use in dirty water applications. The valve construction shall be such as to provide for all internal parts to be removable from the top of the valve without disturbing the valve installation. Rain Bird Corporation Rain Bird Corporation 6991 E Southpoint Road 970 West Siena Madre Avenue Tucson, AZ 85756 Azusa, CA 91702 Phone: (520) 741-6100 Phone: (626) 812-3400 Fax (520) 741-6522 Fax: (626) 812-3411 Rain B4dTedrNcal Services Specification Hotline (BOD) RAINBIRD (1-800-724-6247) 800-458-3005 (U.S. and Canada) (US. and Canada) 0 Registered Trademark of Rain Bird Corporation 02016 Rain Bird Corporation 4/16 V/'1LVC - rCO OCrtll SCALE: NOT TO SCALE Plastic Electric Remote Control PEB or PESB Valve (with PRi Rain Bird Imemational, Inc. 1000 West Sierra Madre Ave. Azusa, CA 91702 Phone. (626) 963-9311 Fax (626) 852-7343 The Intelligent Use of Water• www.ralnbird4wm D3895OPEO Complete Zone Coverage Xerigatione Control Zone Kits (XCZ) provides a complete and easy to install package that will properly deliver water to the drip irrigation system. Rain Bird's XCZ's contain all three essential components to ensure the drip install operates at its optimal performance for years to come. The control zone kits contain three major components: the valve, filter, and pressure regulator. Each component performs an important function on supplying the proper water conditions for the drip irrigation system. Rain Bird XCZ pre-packages these components making it easy for you to select, order, and install. • Decades of proven performance for peace of mind • Commercial or Residential • Low, medium, and high flow rates • Valves for reclaimed water • Valves with Anti -Siphon • Low flow without weeping Prevents sediments and impurities from entering the drip system Extends the life of the drip system for years to come • Basket filters with quick check indicators • Easy to clean commercial disk filters for harsh water Savings Convenience Reliability Pressure Regulation ensures constant outlet pressure for proper operation • Reduces the chance oftube and fitting blow outs • Pressure regulator built into the filter to minimize size (Look for the white dot) • Stand alone options RA,1**B1R,0. 120 Mesh 15-62 1000 to 4000 ft. Stainless 20.75" Jumbo so GPM of dripline 150-PEB Yes Steel 40 PSI 1.5"x 1.5" Length Rectangular XCZ-15D US 030 Micron) 200 Mesh 0.3-20 20 to 1300 ft. Stainless 14" Standard M - GPM 100-PESB of dripline Yes Steel 40 PSI 1"x 1" Length Rectangular XCZ-100-PRB-COM (75 Micron) 20S Mesh 0.3-20 20 to 1300 ft. Stainless 12" Standard GPM of dripline 100-PEB Yes Steel PSI 1"x 1" Length Rectangular XCZ-100-PRB-LC (75 Micron) 120 Mesh 15-62 1000 to 40DO ft. 150-PESBR Yes Disc Filter 40 PSI 1.5"x 1.5" 23,5" Jumbo GPM of dripline (130 Micron) Length Rectangular XCZ-150-LC IM10.3-20 200 Mesh 20 to 1300 ft. Stainless 10.5" Standard Mto EMO GPM 100-PESBR of dripline Yes Steel 40 PSI tax 1" Length Rectangular XCZ -100-PRBR (75 Micron) Ira 200 Mesh Standard AM 3-15 200 to 1000 ft. 100-PGA Yes Stainless 40 PSI tax 1" 11" Rectangular allGPM of dripline Steel Length or 10"Round XCZPGA-100-PRF (75 Micron) 200 Mesh 3-15 200 to 1000 ft. Stainless 10" Standard GPM of dripline 100-DV No Steel 40 PSI 1"x 1" Length Rectangular (75 Micron) or 10"Round XCZ-100-PRF 2DO Mesh 0.2-10 13 to 650 ft. Stainless 10" Standard GPM of dline LFV-100 No Steel S qq PSI 1"x 1" Length Rectangular XCZLF-fro-PRF (75 Micron) or 10"Round 200 Mesh 0.2 - 5 13 to 300 ft. Stainless 10" Standard GPM of dripline LFV-075 No Steel 30 PSI 3/4"x 3/4" Length Rectangular XCZ-075-PRF (75 Micron) or 10"Round Residential Control Zone Kits with Anti -Siphon 200 Mesh 3-15 200 to IDOD ft. Stainless 14" Above GPM of dripline 100-ASVF No Steel 40 PSI tax 1" Height Ground xACZ-100-PRF 75 Micron) ) 200 Mesh OXACZ-075-PRF 0.2-5 13 to 300 ft. ASV- Stainless 14" Above GPM of dripline LFV-075 No Steel 30 PSI 3/4"x 3/4" Height Ground (75 Micron) • Registered trademark of Rain Bird Corporation 02020 Rain Bud Comord len 07M V r'1L V C- A7„dL- I V V-r SCALE: NOT TO SCALE D4i267A Series 825YA / Horizontal Flow In - Vertical Down Flow Out Legend: A Overall lay length, outside dimension B Centerline of inlet shutoff to centerline of ouflet shutoff C Centerline of assemble to top D End of inlet shutoff to cartel of assembly E Centerline of assembly to outside of relief valve F Bottom of relief port to and of inlet shutoff G Centerline of assembly to outside of flange Dimensions - Weights Size: s/a" - 2" (20 - 50mm) SIZE (ON) DIMENSIONS WEIGHT in. mm A Ire rum B in. rum C In. men D in. man Of M. mm E im mm F du 1 G• In. rum Poe % 20 127h 327 12% 308 4% 114 3%% 92 Na Na 4'h 105 3% 89 1% 41 15.0 6.8 1 25 13% 340 12'h 318 4% 114 4 12 Na We 4% 105 3li, 98 i% 41 18.5 7.5 136 1 40 1 18% 1 467 1 17 1 432 6 152 5Y4 1 133 Na I Na 1 5 127 4% 1 tiff 1 2% 1 67 1 3&0 1 172 2 1 50 1 19% 1 492 1 17% 1 448 6 152 51A 149 Na ni 1 5 127 51/. 1 133 1 2% 1 67 1 41.0 1 18.6 t3 Dimension are based on abundant venicxl flow in I vertical now out configumbarm Nola All dhnensiuns are approximate. abunces must be made for normal manuta riming tolaarove. Series 825YA / Horizontal Legend: A Overall lay length, outside dimension C Centerline of assemble to top E Centerline of assembly to outside of relief valve G Centerline of assembly to outside of flange Dimensions - Weights Size: 3/4" - 2" (20 - 50mm) SIZE ON) in. mom A in. rum B m. rum DIMENSIONS c 0 kt rum in. rum D7 in. rum E in. rum F in. rum G in. rum WEIGHT Poe.to ya 20 151h 394 Na Na 4'h 114 n/a Na Na rua 4Ye 105 Na Na 1% 41 15.0 6.8 1 25 18'b 413 Na NIs 4% 114 Na Na Na Na 4'h 105 his Na 1% 41 18S 7.5 11k 1 40 22 1 559 1 file File 1 6 152 Na Na Na Na 5 127 1 Na File 1 2% 67 1 38.0 1 172 2 1 50 1 233A 1 594 1 Na Na 1 6 152 Na Na Na Na 5 127 Na Na 1 2% 67 1 41.0 1 18.6 •G ammdm ae based on standard vertical floe In varaiiper, art emotional dm Rose: Al emmrs are appmximarreWwaawm aW ba made for normal made ar.9Mng rokrences. Typical Installation The FEBCO Series 825YA provides versatility in installation because it can be installed in any of four configurations. The most typical configuration is shown in the vertical up flow inivedical down flow out diagram. This provides for an extremely short lay length which is advantageous in areas of limited space for installation wftivn a protected enclosure. Cost savings can be realized due to the reduction in materials needed such as nipples, elbows, unions, and size of the enclosure. With fie integral flanged union connections, the assembly can be removed from the line for freeze protection without a spool substitution. f is not recommended that any backRow prevention assembly be removed from the line for maintenance unless assurance can be made that a spool cross -connection cannot be substituted. The flanged union connection mounted at 45 degrees will provide this assurance. The FEBCO Series 825YA is shipped in the configuration shown in the vertical up flow/vertical down flow out diagram, but can easily be modified to the three other configurations (shown on Inside of this specification sheet) simply by removing the bolts to rotate the end adapters. With any configuration, material and labor savings can be achieved. The FEBCO Series 825YA is the only Reduced Pressure Zone Assembly which provides these options in a compact, integral assembly. All internal components are interchangeable with the FEBCO Series 825Y providing the same ease of maintenance and reliable operation. Reduced Pressure Zone Assemblies should be installed with a minimum clearance of 12' (300mm) between port and floor or grade. They must be installed where discharge will not be objectionable and can be positively drained away. They should be installed where easily accessible for testing and maintenance and must be protected from freezing. Thermal water expansion and/or water hammer downstream of the backlow preventer can cause excessive pressure. Excessive pressure situations should be eliminated to avoid possible damage to the system and device. BHevkw W aKmrbly in vM'sal in/au[now cadipureeon NOTICE The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation Instructions and product safety information before beginning the installation of this product. ZFEB7 A NNTTS Brand ES-F-825YA 1614 Capacity 1 W lea Pa 1" (25mm) 118 20 103 1s 4H 69 i0 34 5 0 10 20 30 40 so 60 (gpm) 0 38 M 114 276 345 414 Spr) 5 EN is 20 (do) 1b 23 at 49 &1 (mps) we W 1112" (40mm) IN 20• 4 103 15 1 89 10��r I I I I I 1 1#1 34 0 20 w 60 80 100 in (i 5 0 138 Z76 414 552 689 827 op.) 5 (7]4" 10 15 too 1.5 2.3 at 4.6 (mps) 1 MENOMONE PPMEMMMMMN W- mom 5 0 275 552 827 1103 13M less ePN 5 iN 10 15 (10 is 23 3.1 &a (mps) f is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes. Uri Tel: (BOO) 797-1234 • Fax: (BOD) 788-4491 • FEBCoorrinsecom Canada: Tel: (906) 332-4090 • Fax: M 332-7068 • FEBCOonlnfece Latin America: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • FEBCOordine.com ® 2017 FEBCO Job Name Job Location Engineer Approval Series 825YA Angle Pattern Reduced Pressure Zone Assemblies Size: 3/a' - 2" (20mm - 50mm) The FEBCO Series 825YA Reduced Pressure Zone Assemblies are used to protect against toxic fluids in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. They are also used in Irrigation systems, boiler feeds, water lines and other installations requiring the highest level of mechanical protection. End connection - NPT ANSVASME B1.20.1 Features * Installation versatility simplifies new and retrofit installations. • Eliminates pipe elbows, nipples and unions from the installation. • Reduces installation time, labor costs and materials. • Compact design simplifies retrofit. • Integral flanged union connections allow assembly to be removed from the line for freeze protection or maintenance without the danger of spool substitution. • Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. • Modular relief valve and check valve internal components for ease of maintenance. • Smaller, less costly protection enclosures can be Used to provide freeze and vandalism protection due to compact size of valve. • Field tested design for reliability and performance. • Replaceable seat rings for longer valve life. • Low head loss for optimum performance. Operation In a flow condition, the check valves are open with the pressure between the checks, called the zone, being maintained at least 5psi (34 Wall lower than the inlet pressure. The relief valve is held closed by the pressure differential. Should abnormal conditions arise under no flow or reversal of flow, the differential relief valve will open and discharge to maintain the zone at least 2psi (14 kPa) lower than the supply. When normal flow resumes, the zone's differential pressure will return and the relief valve will close. Approvals - Standards • Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. • ANSVAW WA C511 Conformance ® s1®�® 1013 B64A Contractor Approval Contractor's P.O. No. Representative Specifications The reduced pressure zone assemblies shall consist of two inde- pendently operating, spring loaded, "Y" pattern check valves and one hydraulically dependent differential relief valve. Should the differential between the upstream and the zone of the unit drop to 2psi (14 kPal the differential relief valve shall open and maintain the proper dfferential. Mainline valve body and caps including relief valve body and cover shall be bronze. Check valve moving members shall be center stem guided. Relief valve shall have a removable seat ring. Check valve and relief valve components shall be oonstructed so they may be serviced without removing the valve body from the line. All seat discs shall be reversible. The assembly shall include flanged unions located between the mainline valve body and the bell valve shutoffs to allow for field removal for freeze protection or maintenance without danger of spool replacement. The assembly shall be rated to 175ps( (12.1 bar) water working pressure and water temperature range from 32OF to 140OF (00C - 60°C). The assembly shall meet the requirements of the USC Foundation of Cross -connection Control and Hydraulic Research, Eighth Edition. The assembly shall be a FEBOO Series 825YA or prior approved equal. Materials Main valve body: Bronze Relief valve body: Bronze Bastomers: Nitrile Seat Discs Diaphragms: Nitrile, fabric reinforced Springs: Stainless Steel Pressure - Temperature Maximum working pressure: 175psi (12.1 bar) Hydrostatic test pressure: 350ps1(24.1 bar) Temperature range: 32-F to 140-F (Oat to 60-0) FEBCO FEBCO product specificationsin U.S. customary units and meBo are approximate and are provided for reference only. For precise measurements, please contact FEBCO Technical Service. FEBCo reserves the right to change or modify product design, co min iion, specidcan"cal or Materials with- out prior notice and withwR incurring any obligation to make such changes and modifications on FEBCO products previously or subsequenify sold. A WATTS Brand Series 825YA / Vertical Up Flow In - Vertical Down Flow Out Legend: A Overall lay length, outside dimension B Centerline of inlet shutoff to centerline of outlet shutoff C Centerline of assemble to top D End of inlet shutoff to centedine of assembly D1 Centerline of assembly to end of outlet shutoff E Cenedine of assembly to outside of relief valve F Bottom of relief port to and of inlet shutoff G Centerline of assembly to outside of flange •) i Dimensions - Weights Size: 3/4' - 2" (20 - 50mm) SIZE (ON) In. rum A im rum B in. mm DIMENSIONS C D kl. rum In. rum D1 In. rum E in. rum F 1, rum G In. I rum WEIGHT Pos. I74 20 10 254 8Ya 218 3Y4 83 47h 124 4% 118 4'A 105 ark 89 1% 41 15.0 6B 1 25 101/4 260 8'h 218 3Y� 89 5Y4 133 5 127 4% 105 37h 98 1% 41 18.5 75 1% 40 141/4 332 111h 292 411 1 114 1 1 1 175 1 8'h 1 165 1 5 1 127 4% 1 118 1 2% 1 67 1 38.0 1 17.2 2 50 147A 378 11'h 292 414 1 114 1 7% 1 191 1 71h 1 181 1 5 1 127 5'h 1 133 1 2% 1 67 1 41.0 1 18.6 N3amaannera Mead apslydeti verl flow 0 bep Bowoutarmal manare Nob:N dhwaiona xe approdmeh. alownraes muatM metlafa rremd nnradectudr0 references. Series 825YA / Vertical Up Flow In - Horizontal Flow Out Legend: A Overall lay length, outside dimension B Centerline of Inlet shutoff to centerline of outlet shutoff C Centerline of assemble to top D End of inlet shutoff to centerline of assembly E Centerline of assembly to outside of relief valve F Bottom of relief port to end of inlet shutoff G Centerline of assembly to outside of flange :��(Ca�_. u�r •III Dimensions - Weights Size: 3/4" - 2" (20 - 50mm) SIZE ION) DIMENSIONS WEIGHT in. rim A h. rum B ti. mm C Nt rum D in. rum D1 m. rum E in. rum F in rum G in. rum Poe.to V4 20 12% 311 117h 112 11h 114 3% 92 Na Na 4% 105 3'h n 1% 41 15.0 6B 1 25 13% 3n 1T/4 311 4% 114 4 102 Na Na 4% 105 3% 98 1% 41 18.5 7S 1% 40 18 457 16sh 422 8 152 5% 133 Na Ne 5 127 4% 118 2% 67 38.0 17.2 2 50 19 4W 171A 438 6 152 57A 149 Na Na 5 127 5Y4 133 2% 87 41.0 18.8 'G Ch amen are based em funded vertical floe in /easel row out mnOpuaGm. None All dimensions are apprwimate. alaeancn runtM made V normal moeratd"tdmanaa Z EE W W W W Z F W LU Z W H W (,r LU ZWWV) jW Zr0 1--otrU) Fwax wZ >ZUwxn0 r=n Q Q Z Q ZxnMwZFI- of 0Zaof aa~O Q 0 U I- o_ Z J 0 0 Z) W Z Of Z o Q > aJ U W REVISIONS REV DATE COMMENT CxacxEo er 1 10/29/2021 PER ISP COMMENTS DSH RTY 2 01/21/2022 PER COUNTY COMMENTS BSC RTY 3 04/OS/2022 PER COUNTY COMMENTS BSC RTY ia Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: LSCP -2 PROJECT SITE PLAN DOCUMENTS FOR DISC®C�7aQ PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@,BohlerEng.com 747 NICHOLAS T GEOR( Cert. No. 001653 r9'yO 8/27/2021 s c G q P R E A SHEET TITLE: IRRIGATION NOTES AND DETAILS SHEET NUMBER: C-708 SCALE: NOT TO SCALE REVISION 3 - 04/08/2022 J w Z ro r Z Z 0 a ce rr n U 0 0 3 A 0 z 0 N R.4/N*B/RD 1800m Series Spray Heads Industry's Leading Sp:,( ' Ik-J :; , Trusted for over 30 years, 1800 Series Spray Yea P Y Heads have provided unmatched durability, reliability, and performance. Superior components and features make the 1800 Series Spray Head the spray head of choice fora wide variety of applications. Features Co -molded, pressure -activated, mut i-func- tional wiper seal assures positive seal without excess'Row-by"which enables more heads to be installed on the same valve. • Designed for use with all Rain Bird plastic spray head nozzles- Rotary Nozzles, U-Series, MPR, VAN and XPCN Series. • Precision controlled flush at pop -down clears debris from unit, assuring positive stem retraction in all soil types. • Strong stainless steel spring provides reliable stem retraction. • Ratchet mechanism on all models allows easy nozzle pattern alignment without tools. • Pre4ristalled 1800 Pop Top"flush plug blades debris from entering afterflushing. Allows for easy nozzle installation. • Constructed of time -proven UV -resistant plastic and corrosion resistant stainless steel parts, assuring long product fife. • All sprinkler components are removable from the top without special tools, providing for quick and easy flushing and maintenance of the sprinkler. • Side inlets featured on 1806,1806PRS, 1812, and 1812PRS models only. • Five-yeartrade warranty. Operating Range • Spacing: 2.5 to 24 feet (OBto 73 m) • Pressure: 15 to 70 psi(1.Oto4.8 bar) Specifications • Flow -by: Oat 8 psi (0.6 bar) or greater; 0.1 gpm (0.02 m3/h; 0.00(5 Vs) otherwise Dimensions Models • Y2"(15/21) NPTfemale threaded inlet • Models and height 1802:4(10 cm) body height; 2"pop-up height (5 cm) 1803:4'W(12 cm) body height; 3"pop-up height (7.6 cm) 1804:6'(15 cm) body height 4"pop-up height (10 cm) 1806:9 %"(24 cm) body height 6"pop-up height (15 cm) 1812:16"(40 cm) body height; 12"pop-up height (30 cm) • Exposed surface diameter. 2Y4(5.7 cm) 1804 - SAM - PRS - P45 Optional� PRS: 30psi (2.1 bar) o-stem pressure regulation Optional P45:45psi (3.1 bar) in -stem Feature pressure regulation SAM: Seal-A-Matic" Model check valve 1804-.4"110.2 cm) pop-up height Note: SAMfmtureirdudsdwlth P45modeh 1804 - SAM-P45 - R13-18Q eneen Rotary Nozzle R Radius flange Optional 13-18' (4.0 - 5.5,m) Feature 17-24'(52-7.3m) SAM: Pattern Seal-A-Matic" F. Full(3601 check valve TQ:Three Quarter RAM P45:45psi(3.1 TT Two Third (2401 bar)instem H:Half(1801 pressure T.Third (1201 regulation Q:Quarter(W) Model 1804:4"1102 cm) popup height Note: spedfyspnnkferbodizsandnoalasearately Tech Spec PRS ip SAM .SAM-PRS4D SAM-PRS-P45 1800" Series Spray Heads Tech Spec 1800° SAM Series 1800 PRS Series 1800 SAM-PRS Series Ideal for use in areas with changing eleva- Designed for areas with high and/or widely Meets the needs of all spray areas, regardless tions, the 1800 SAM Series offers all 1800 fluctuating water pressures, the 1800 PRS of changing elevation or water pressures. Series features plus: Series has al 118W Series features plus: Incorporates all 18M Series SAM and PRS • Built-in Seal-A-Matic"(SAM)check valve. •PATENTED PRS pressure regulator built features."SAM-PRS"stamped on the cap for Eliminates the need for under -the -head re into the stem. No parts to be installed at easy identification and maintenance. check valves No parts to be installed at the site. Saves time and money. Operating flange the site. Maintains constant outlet pressure at • Stronger retract spring to accommodate 30psi (2.1 bar). Spray nozzles perform • Spacing: 25 to 24 feet(08 to 7.3 m) elevation changes upto 14'(42 m).Oneof best at 30psi. Ensures maximum nozzle . Pressure: 25 to70 psi(1.7to48 bar) the strongest springs in the industry. performance, even with varying inlet • Prevents drainage from spray heads at pressures. Maintains constant pressure Specifications lower elevations. Stops waterwaste. Ends regardless of nozzles used. .SAM capability: holds up to 14 feet (42 m) landscape damage due to flooding and/ Restricts water loss by up to 70%ifnozzle ofhead; 6 psi (03 bar) or erosion. is removed or damaged. Saves water and •Flow-by:0at8psi (0.6 bar) or greater; • Helps retain water in lateral pipes which money. Reduces possibility of accidents 0.1 gpm (0.02 m3/h; 0.006 Vs) otherwise reduces wear on system components by and property damage. Recommended for ' Installation: bottom inlet only minimizing water hammer during vandal-proneareas. • Regulates nozzle pressure to an average 30 start-up. • Designed for use with all Rain Bird plastic Ensures consistent performance throughout zone if nozzle is removed or psi (2.1 bar) with Inlet pressures of up to 70 spray head nozzles. damaged. Keeps plant life covered by psi (48 bar) • "SAM"stamped on cap for easy other spray heads properly irrigated. Dimensions identficationand maintenance. Ends mistingand in caused high • Five-year trade warranty. pressure. Stops water waste. Ensures h"(1521) NPrfemalethreaded inlets necessary watering occurs in high pressure Body height 1804SAM-PRS -6"(15 cm), Operating Range or wind conditions. 1806 SAM-PR5 - 9%(24 cm), 7. • Spadng:2S to 24feet (08to 7.3 m) Designed for use with all Rain Bird plastic 1812 SAM-PR5-16"(40 an) • Pressure: 25 to 70 psi (1.7 to bar) spray head nozzles. Exposed diameter. 2% (5.7 cm) • "PRS°stamped on cap for easy Specifications Identification and maintenance. Models • SAM capability: up to l4feet (42 m) isii • Five-year trade warranty. • 1804 SAM-PRS:4"pop-up height(10cm) 6 of head; 6 psi (03 bar) (03 bar) Operating Range . 1806 SAM-PRS: 6"pop-up height (15 cm) • Flow -by: Oat 8 psi (0.6 bar) or greater, Spacing:25 to 24feet (08 to 73 m) 1812 SAM-PRS:-up height (30 tm) 0.1 gpm (0.02 m3/h; 0.006 Vs) otherwise Pressure. 15 to 70 psi (1 to 5 bar) • Installation: bottom inlet only Dimensions Specifications ' i4°(1521)NPT female threaded inlets • Regulates nozzle pressure to an average 30 • Body height 1804SAM -6"(15 cm), psi (2.1 bar) with inlet pressures of up to 70 1806 SAM -9Ye°(24 cm), psi(48 bar) • Flow -by: 0 at 8 psi (0.6 bar) or greater, 18125AM 16°(40 on) 0.1 gpm (0.02 m3/h; 0.006 Vs) otherwise • Exposed surface diameter. 2Y4 (5.7 cm) • Installation: side or bottom inlet Models • Side inlet installation not recommended in freezing climates • 1804 SAM: 4"pop-up height (10 cm) • 1806SAM: 6"pop-upheight (15 cm) Dimensions • 1812 SAM: 12"pop-up height (30 cm) - y3"(1521)NPTfemalethreaded inlets • Body height 1804 PRS -6'(15 cm), 1806PRS-9% (24cm), 1812 PRS-16"(40 cm) • Exposed surface diameter...2Ye(5.7cm) Models • 1804 PRS:4"pop-up height (10 cm) • 1806 PRS:6"pop-up height (15 cm) • 1812 PRS: 12"pop-up height (30 cm) D SPRAY HEAD - 180 -710J SCALE: NOT TO SCALE RAW4B/RD 813WM20I Page 1 of 1 NIBCO Tech Spec 1516 Middlebury Street p Elkhart, IN 46516-4740 N' BCC• Phone: 574.295.3000 • Fax: 800.234.0557 AHEAD OF THE FLOW. E-Mail: infoOnibco.com • Web site: www.nibco.com ,.IAOK FOR., XFS Dripline With Copper ShieldTM Technology ,r .. r 'M. ' Jr. • It accepts Rain Bird Easy Fit Specifications Compression Fittings, XFF Dripline Barbed Insert Fittings and other • OD:0.634" 17 rum barbed insert fittings • to: 0.536" g • Thickness: 0.049' • Rain Bird's low -profile emitter design • 12" 18" (30,5 cm, 45,7 cm) spacing reduces in -line pressure loss, allowing . Available in 1Wand 500' longer lateral runs, simplifying design (30,5 m and 152,4 m) coils and reducing installation time • Coil Color. Copper, Purple, Copper -Variety of emitter flow rates, emitter with Purple Stripe spacing and coil lengths provide design flexibility for either sub -surface turf grass or sub -surface shrub and groundcover applications SUB -SURFACE Reliable Applications • XFS emitters are protected from root intrusion by Rain Bird's Rain Bird' XFS Dripline with Copper patent -pending Copper ShieldTM' ShieldTM'for sub -surface drip irrigation Is Technology resulting in a system the latest innovation in the Rain Bird that does not require maintenance Xerigation"' Family. Rain Bird's patent- or replacement of chemicals to pending Copper Shield"'Technology protects the emitter from root prevent root intrusion intrusion, creating a long-lasting, low I • • • " maintenance sub -surface drip irrigation -The pressure -compensating system for use under turf grass or shrub emitter design provides a consistent XFS-04-12-500 XFSP-04-12-500 and groundcover areas. XFS Series flow over the entire lateral length XFS-04-18-500 XFSP-0418-500 Dripline with Copper ShieldTM is perfect ensuring higher uniformity for XFS-06-12-100 XFSP-06-12-500 for small, narrow and tight planting increased reliability in the pressure areas, as well as areas with tight curves range of 8.5 to 60 psi XFS-06-12-500 XFSP-06-18-500 or many switchbacks XFS-06-18-100 XFSP-09-12-500 It accepts Rain Bird Easy Fit Durable XFS-06-18-500 XFSP-09-18-500 Compression Fittings, XFF Dripline Dual -layered tubing (copper over XFS-09-12-100 XFSPS O4125 Barbed Insert Fittings and other 17 mm black) provides unmatched resistance XFS-09-12-500 barbed insert fittings. to chemicals, algae growth and UV XFS-09-18-100 XFSPS-04-185 damage XFSPS-06-125 XFS-09-18-500 Features Grit Tolerant: Rain Bird's proprietary XFBlanktubingalso XFSPS06185 Simple emltterdesignresists clogging byuse available in brown, XFSPS-09-125 Rain Bird's patent pending shiny metallic of an extra -wide flow path combined spupl,andspurple XFSPS-09-185 copper -colored XFS dripline with with a self -flushing action Copper Shield -Technology protects • • • - theemitterfromrootintrusionwith Operating Range out requiring EPA -approved handling XFS - 06 - 12 - 100 procedures - unlike some • Pressure: 8.5 to 60 psi L58 to 4,14 manufacturers who use harsh bar) chemicals or treated filters to Coil Length protect the emitter from root intrusion • Flow rates: 0.42, 0.6 and 0.9 gph (100 Feet) -Through the use of a proprietary (1,61/h, 2,31/hr and 3,5 Vhr) (2 Emitter Spacing 7 F tubing material, the shiny metallic •Temperature: Model Flow Rate copper -colored XFS Dripline with Water: Up to 1GOT (37,8" C) (0.6 GPH) Copper Shield' is the most flexible Ambient: Up to125°FIS1,7°C) XFSP= Purple to indicate models dripline tubing In the Industry making RequiredFiltretion:120Mesh that use non -potable water it the easiest sub -surface dripline to XFSPS= Purple stripe to indicate models design with and install that use non -potable water RA/N�kB/RD XFS Dripline With Copper Shield" Technology Dripline Series Specifications The flexible, shiny metallic copper -colored polyethylene tubing shall have factory installed pressure -compensating, inline emitters spaced evenly per listed spacing. The flow rate from each installed inline emitter shall be 0.4, 0.6 or 0.9 gallons per hour when Inlet pressure is between 8.5 and 60 psi. The Inline emitter diaphragm shall have a pressure -regulating diaphragm with a spring action allowing it to self -rinse if there is a plug at the outlet hole. The flexible tubing allows for easy non -linear installations. The inline emitter shall have copper shield technology installed to protect the emitter from root intrusion. The inline emitter inlet shall be raised off the Inside tube wall to minimize dirt intrusion. The XFS Dripline inline tubing shall be manufactured by Rain Bird Corporation, Azusa, California. Inlet Pressure Maximum Lateral Length (feet) Inlet Pressure Maximum Lateral Length(meters) psi 12" Spacing bars 3o.5 an spacing Nominal now (GPH): Nominal Flow (YN: 0.42 0.6 0.9 lb 23 35 15 352 273 155 1.0 1072 832 472 20 399 318 169 1A 121.6 96.9 515 30 447 360 230 2.1 1362 109.7 70.1 40 488 395 255 26 148.7 120A 779 50 so 417 285 35 153.9 127.1 86.9 60 573 460 290 4.1 1746 1402 88A 18" Spacing 45.7 cm Spacing Nominal Flow (GPH): Nominal Flow (I/h): OA2 0.6 0.9 16 23 35 15 374 314 250 _ 1.0 114 95.7 762 20 417 353 294 1A 127.1 1076 896 30 481 413 35D 2.1 1466 125.9 106.7 40 530 465 402 26 1615 141.7 1225 50 610 528 420 35 185.9 160.9 128.0 60 734 596 455 4J 223.7 181.7 138.7 LEED Compliant Contains at least 20% post consumer R�9 li L E E D recycled polyethylene which qualifies --- LEED credit 4.2 Rain Bird's Professional XF Series Dripline offers five (5) years on product workmanship Customer Satisfaction Policy and seven (7) years on environmental stress cracking Rain Bird Corporation 6991 E. Southpoint Road Tucson, AZ 85756 Phone: (520) 7416100 Fax (520) 7416522 Rain Bird Technical Services 1800) RAINBIRD (1-800-7246247) (U.S. and Canada) • Registered Trademark of Rain Bird Corporatlon 0 2017 Rain Bird Corporation 01/20 Lnrtlrulvr-- - nro %.,U SCALE: NOT TO SCALE Rain Bird Corporation 970 West Sierra Madre Avenue Azusa, CA 91702 Phone: (626) 812-3400 Fax (626) 812-3411 Rain Bird International, Inc. 1000 West Sierra Madre Ave. Azusa, CA 91702 Phone: (626) 963-9311 Fax (626) 852-7343 The Intelligent Use of Water' www.rainblyd.com D39978B Material Number N11.998HB, T-FP-600A - Ball Valve - Brass, Two -Piece, Full Port, NPT x NPT The NIBC00 brass ball valve provides ease of operation with quarter -turn (90 degrees) open to close. The two-piece valve features threaded end connections for easy installation. Please refer to NIBCO technical data sheet, valve selection guide and catalogfor engineering and installation information. Choose NIBCO ball valves for the most specified, versatile and 9 9 � P , economical valve option in commercial and residential applications. NIBC09 specialty valves are backed by a NIBCO INC. 2-year limited more UPC Code 039923276636 Type Ball Valve Valve Size 1 1/4 in Body Material BRS Brass Cold Working Pressure 600 psi Operation Type Standard Lever Handle Connection Type T -- Female NPT Thread (FIPT) Flow Coefficient 103 Description TFP600A 1 1/4 60OPSI THD FULL PORT BV Weight 1.570 lb V ML- V G - OT1LL V P%L' SCALE: NOT TO SCALE I - a Z 0- a z r tl L 0. F- y B to o m Z m c CD = U O a O3 o CL -I LL Z r a L G C ❑ O $ E 0mtp � c CO 6N w o W d N a ZO to p C N to N C 3 N 'O L°E=� r > m O Z RA/H*B/RD Quick -Coupling Valves Convenient water access in potable and non -potable systems Features • Industrial -strength brass quick -coupling valves for convenient water access in potable and non -potable systems. • Rugged, red brass construction for long life and reliable performance. • Reliable leak proof operation with strong corrosion -resistant stainless steel spring. • Optional locking cover on models p 33-DLRC, 44-LRC, 5-LRC, 33-DNP, • 44-NP, and 5-NP(use ' 2049 key to unlock). Metal cover on model 7 only 1 • One-piece body design (models 3-RC, 5-RC and 7) • Two-piece body design for easy servicing Oulckcouplingvalves (models 33-DLRC, 33-DRC, 44-LRC, 44-RC, 33-0NP, 44-NP, and 44-NP ACME) - • Thermoplastic rubber coverfor durability • 33-DNP,44-NP,44-NPACME, anc15-NP covers marked with "Do Not DrinleIt warnings in English and Spanish • Three-year trade warranty 9 Specifications _ • Pressure:5 to 125 psi (035 to 8.63 bar) 33 44-NP ACMEP 7 • Flow: 10ro 125 gpm (2.27 to 2838 m3/h; 378 to 4731/m) • 5-LRC-BSP 1"(26/34) Locking Rubber • 33-0NP, 44-NP and 5-NP flow: 10 to 70 Cover, 1-Piece Body, BSP threaded gpm(2.27to 15.89 m3/h; 378to2651/m) . 33-DNP.34"(20/27)Non-potable, Purple Models Locking Rubber Cover, 2-Plece Body • 44-NP:1°(26/34)Non-potable, Purple • 3-RC 34"(2027) Rubber Cover, l-Piece Locking Rubber Cover, 2-Piece Body Body • 44-NP ACME 1"(26/34) Non -potable, • 33-DR0 34"(20/ 27) DoubleTrack Key Lug, Purple Locking Rubber Cover, 2-Piece Rubber Cover, 2-Piece Body Body,ACMEthread • 33-DLRC: 3W(2027) DoubleTrack Key Lug, • 5-NP.1"(26134)Non-potable, Purple Locking Rubber Cover, 2-Piece Body Locking Rubber Cover, l-Piece Body • 44-RC:1"(26/34) Rubber Cover, 2-Piece Nine. F.,nort-US ppikadom, iris crrywsadfy Body NProrBSPthrmdtype • 44-LRC: 1"(26/34) Locking Rubber cover, Dimensions (height) 2-Piece Body • 5-RC 1 °(26/34) Rubber Cover, l-Piece Body • 3-RC: 41/4" (108 cm) • 5-LRC: 1'(26/34) Locking Rubber Cover, .33-DRC: 43/4(11.1 an) 1-Piece Body • 33-DLRC 45A' (11.7 an) • 7: 112(40/49) Metal Cover, 1-Piece Body • 44-RC 6(15.2 cm) • 5-RC-BSP 1"(26/34) Rubber Cover, l-Piece •44-LRC6"(152cm) Body, BSP threaded • 5-RC:5'k' (14Aan) Tech Spec J Quick -Coupling ValeCutaway t • 5-LRC:5'7e'(14.0 em) • 7: 53h'(14.6 an) • 33-DNP:4W(11.1 cm) • 44-NP 6"(152 an) • 44-NP ACME 6'(152 an) • 5-NN..5'k'(14.0 cm) 33 - DLRC Model cover Thread 33 RC Blank NPT 44 DRC BSP:5-RC,5-IRConly 5 DLRC ACME:44NPonly 7 LRC DNP NP Note: Thisspecdmso33-OLRCmim3/4"f20/27)quick mupling typaoptiorwllocking rover. R.4/N]�kB/RD. Z EE LU W W rn z - of U3 Z W H 0 W 0 Z W W W j W ZrCDHQofCO -W<= wZ -]>ZUwra0 r=n Z1 M Q Q Z Q Z U)MWZFH Of 0Zof< 0 Q U I- o_ Q J Of 0 Cn W Z z o Q > aJ of U w H rn REVISIONS REV DATE COMMENT 1 10/29/2021 PER ISP COMMENTS 2 01/21/2022PER COUNTY COMMENTS3 IB 04/08/2022 PER COUNTY COMMENTS I Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: LSCP -2 PROJECT SITE PLAN Specifications 33-DRIC,33-DLRC,44-RC,44- RC -Two DOCUMENTS Piece Quick Coupling Valve , ' 33-DNP, 44-NP, 44-NP ACME -Two Piece Flow 34K 33-DRC 4441C 5-R( 7 Quick Coupling Valve (Non -Potable) The quick coupling valve shall be a two piece 33-KRC 44LRC 5ARC FOR type capable of having a discharge rate of 33-DNP 44-NP 5-NP The quick coupling valve shall be a two piece with a pressure loss not to exceed 44NP ACME typecapablehavingure discharge rate __units QPM 'Aff 32 7" 1" Ph" with a e _unitswithapressureloss not toexceed -units 10 1.8 2 - - - D' S IC M U Imo, "n `(�1] _units The valve body shall be constructed of red 15 41 43 22 LJ�J (�] The valve shall be constructed of red brass brassThe cover shall be a durable, protective 20 72 7.6 4.4 - - GOEM andshallhaveapurple, thermoplastic lack- self -closing rubber cover. When so specified, 30 - - 11.5 4.1 - Ing rubber cover with molded -in warnings of the cover shall be a locking mbber cover 40 - - - 73 - 'DO NOT DRINK"in English and Spanish, for O.Rn s0 - - - 11 1.7 PROPOSED use on systems using non -potable water. The valve shall be opened and closed by a 60 - - - 15.7 2.S brass key of the same manufacturer having 80 _ _ _ 215 49 LOCATION The valve shall be opened and closed by a a_"(MNPT)and outlet The brass key of the same manufacturer having _"(FNPO valve throat shall have a key -way with decent 100 84 1636 SEM I NOLE TRAIL a_"(MNPT)and _"(FNPT) outlet The �.. regulating sitions for ulatin water flow. 125 - 14 ALBERMARLE COUNTY valve throat shall have a key -way with detent positions for regulating water flow. CHARLOTTESVILLE, VIRGINIA22901 1 TOPPIPETHREADS C 5-RC 7VALVE QUICK COUPLING VALVES-3-RC, 5-RC, KB MALE FBAALE( =19wMcm 5-LRc5-LRC,7- One Piece Quick Coupling Valve 3-R( 33DK Y4" 19 rum 'h" 13 rumP 5-NPThequipacoupling valve -piece 33-DRC 33DK Yl' 19 rum 'h" 13 rum m CME 2.5 cm 3.8 cm ischar erne type capable of having a discharge rate of 33-NP 33DK Y4" 19 mm 'h" 13 mm 2.3 38 0.12 0.12 - - - B 0 H L E R �� _ units with a pressure loss not to exceed 44-NP 44K 1" 25 mm A" 19 mm 4 67 CIA 0.42 0.23 - - _units. 44-NPA(ME 44KA 1" 25 rum 34" 19 mm 5 83 0.57 0.62 0.40 - - 44-RC 44K V 25 mm 3a" 19 mm The valve body shall be constructed ofred 5-RC 55K1 1" 25mm - - 6 100 - - 0.62 - - 2150 ASHLAND RD. SUITE 200 brass.The cover shall be a durable, protective 5-111) 55K7 V 25mm - _ 7 117- - 0.83 030 - RICHMOND, VIRGINIA 23146 self -closing rubber cover. When so specified, 7 7K 1Y:" 38mm - _ 8 133 - - - 0.40 - the cover shall be a locking rubber cover 9 150- - - 0.50 - Phone: (804)893-8200 (LRq, 10 167 - - - 0.61 - _ Oaaw4• m.m 12 200- - - 0.85 0.13 VA@,BohlerEng.com The valve shall be opened and closed by a O 3„,„•e °�M� 14 233 - - - 1.15 0.18 brass key of the same manufacturer having O.0„o(„�, MD 16 267- - - 1.50 0.25 a_"(MNPT)and _"(FNPT)outletThe 0,,,,;�,,,PhEwum� 22 367- - - - 0.54„�n�„ valve throat shall have key -way with decent O,„a,„xwp"re 28 473- - - - 0.97 `jam positions for regulating water flow. ©•^�"F '7i�1' wT:T„w:T"rET," "�` Ran vdunare with Rawmnrmlmltyppm. O Rain BiNmommends Bownrtesin the suppylmerrotroemM75R/set .y / •Cover Key -Model 2049 gw „„,,,„,' R3Ms)inaNnmreduretheeHemo/wotehommn. / (D a„,",,,"w 2)(arBaWkhxv59Wa(Im3/0;3211s)Foin&1dMrsMob1meal • Locks and unlocks the optional locking 0,�,",xTR�„,,,^ „"„ uAstreamnmohoaroorerenteebashammlem'ngbeiowrneemknmym. NICHOLASTGEO GAS cover(LRC) on quick coupling valves. ,"gym::". 3)Forll.bekwiOgpmOm3M;63Us)RenNNnevx.ndsthmthe pe p • Operates the valve markercom ression P6Rs-Bmne�rc tw�txoNlltums/rpmrhefulfyapertposmm. aMymRpwwteslnarembebw � Cert. No. 001653 � lock FU4ww�c a"w':.""o «,un nTiram salmure. 9y� Q 8/27/2021 •,.r,�/ sCq PE Rain Bird Corporation Rain Bird Corporation Rain Bird International, Inc. A. 6991 E Southpoint Road 970 West Siena Madre Avenue 1000 West Sierra Madre Ave. Tucson, AZ 85756 Aria, CA 91702 Azusa, CA 91702 Phone: (520) 7416100 Phone: (626) 812-3400 Phone: (626) 963-9311 SHEET TITLE: Fax (520) 7416522 Fax (626) 812-3411 Fax (626) 852-7343 Rain BbdTedudcal services Specification Hotline The Intelligent Use of Water IRRIGATION IBM) RAINBIRD (1-800-7246247) 80P458-3005 (U.S. and Canada) www.rainbird.com (U.S. and Canada) NOTES AND 0 Registered Trademark of Rain Bird Corporation 02017 Rain and Corporation 9/17 D38950QE0 DETAILS SHEET NUMBER A) VALVE - QUICK COUPLER VALVE CUT SHEET I C- / O9 -710J SCALE: NOT TO SCALE REVISION 3 - 04/08/2022 w Z In O Z 0 n U 0 0 3 c6 0 N Z g a Z LL w Z s a Z z_ 3 X 0 a U I >r R 0 in E O V Y M ea QJ 0 H v V Z s H 5 � L � C O CL ro > 1 i 0 1 1 1 a 1 z r 4c ?'is � L rn z 0 to a N p'C t Q. r 2 M In x w � rn . oC C ^PNON nnnn o Ooo �. N a�ON 000nnn E. C NONMON 000nnn �. •a P:}V,a O oNo N ��000 .a P:}<.a N NPN�.a OOoo OOoo 000 Oo0 000 e� N �6irt�N pd Ye.ao�RD,R N ey 11. Crt I� N woo.R�.a pd Se 1 Nma N .aoo.4�i IL 1 1 N.a Pe�$.a woo.4 vl 'pIL P 1 .a Te�$.a woo.4 vl 000 S 00'O a. 000' S Oo0' 00'O E 00'O m�?Oy� of Nrr.�- Hriam ^ CC .n �0o0N0 IOLImO "0s ¢Em LLlO( N P.Emi0 oo00ry 0 hpL 1b0 0m "a0 ����N • yq CZr N�an�mm p, O.'.L NNfNV NfpV fYV yq CRr ���Nf,O la <NVKIN VKIb .Y -pq CZr mOm,•O�ON �a"i N"�"� CNNNNV) yq 6Zi ux N-�N X % CNNNVKI .O jp2jp, 2! zR �s�• e omor 42o 0 1N a® m sh� 6m 4 6riubi1N ���i'mvarv��maarv��rvavrv�- . nnnnnnnnnnnnnnnnnnr:nn nn:'mvvN� nnnnnnr:nn ennn�menn`n�me����me nnn nnn nnnn o0c0d0o0o0 o0c0.0d0o0oy0 op0c0o0d o0o0 o0c d d do do o9cpocbomdbc1 dQ e 4Q9.y.pm•a4''.D, m.a mm.y.ym.G4Q .y".dQdQbd yd "do'diiZdO.dZyd ycbco'dQ bcyd yd0cbc;d4 e 6[ 00000 00OOO O ........... ... c, O0 0000'Oo e E Eaa �NNm 1Qt� ^ O�.O iiryu)Nryg•,�^Iry^Iv1R°4mg6ry?^.S, OO 0,0000ap apN m OOnmNNm too•-ryryi0 OmP 01m�,m.'INrirv.-� nrvrv.-���ry � � �� OOOO Ccimmnh36 GGGCCO 00000'0 4 3 is Qa PrvOry NNN PN,VNNN�,O.I,N.INNN �Nry NNN �ryeNV IMtl Ia-aN �IOVN�Ip-I,p-I PIO-I fNV fV,P-I,@-IPNNN,PVNPryINVryryN ry z gB i o,��"�N'^o :�a„o�,^om�a„oi�om` a,.oi�on�e,.oiN mn�evoiNn pNONO n SON N,.4iMQONN p p1nNN M,Nv,QC G N ry Nit N N A 'E O N��maammm �<mmm ^a amMaa�an�mmN���mmN N.^mac. mrvnneo nneo E. no nmm nnoni: neon nod nnnn n.q .q nnn nnnn nee mm�nnm n`�nnnm 66 dd000 odoco 'dodo'cdoococdcccccdcccdcdddcdddcddddddd d o 3261 odddodo6dddddood00000e00000000000000dood00000066000000 pp rvorye onN�o n .o Jyya�n�N nF mrvn o,�am m�mmN a.-eNNna S rv^o^ham ^??�io^^ry^Ia?4o�noo R°R a1 .,too Onn aao No NvlryMnlmMm ryry Nnrvry 1ITT �o� .o .O o00o coca d00000d0000d ddd 9 rya .Own�m m.aNn�mm mNn-mm bbn. m m Nbn-mW b.Or^m m.D �O^^Wmb.p^^m m.a .a^^tam o,:1.i�„oi"'om��„oi"'om"�„oi"'om`a,.oi�oniavoi h,onm�v��mm ee��m NON I m M m m Mae`P�P`'a N 4Y ry n n � A n .nn^,nrenl�nnn'nnnnnnn'����nnnl., c;i n n nnnnnnn o d o o nnn nn o ood00000ddododddd n �n n nn n nn I-,000d00000d00000d00000d00000d0000 ej Prl'Om�O 6 C mm.0 cccdcdcccdcccccdcocooe000 mm� y.ppry p�pQf�tan •R •Q •O p,p 1� m VN.R . e. oo yip r� b R. o eo. yip ny�p O. •Q b . O O e000 mmny�p V b •D. b b o000cc mmn b.Q O... cocc Jr r�fTmmP���nnm nNmN coca.=�docoo.-oc000000c0000 O p.p {aO.D�nN�a..lul•a.41�1�<Y,Nn.r(V,'Q m m m ..ppm� emu m m rvN 00000 na �maN nl Mo ao e,<.n 000000doodcddooddoddo N maw Haas.-�N.o N•Vmmm m'. ^.NNN N.-.-�^PfOV vN.a O gga arr!��p��Nm����NMma�hNmmaghNmm^vhNmMa�NNmM^�^Nm'e�^NmMv��v, �om$a.on,nom.'r"�9,�om�a,oi�om�a,oihom�e,oi�om$aN,Nn o,N.1$e�L^imm$aN �,4s,Nn$au4� Y S N 9sw ry I. N . 1 NOZZLE - VAN SERIES ROTARY NOZZLES CUT SHEET SCALE: NOT TO SCALE Spray Nozzles MPR Nozzles 30' Trajectory Nozzle Pressure Radius Flow Precip Piet psi ft. gpm In/h In/h 15F 15 11 2.60 2.07 2.39 20 12 3.0 .01 . O 25 14 3.30 1.62 1 1.8787 1 30 15 3.70 1.58 1.83 15H 15 11 130 2.07 239 20 12 150 2.01 232 25 14 1.65 1.62 1.87 30 15 1.85 1.58 1.83 15Q 15 11 0.65 2.07 2.39 20 12 0.75 2.01 2.32 25 14 0.82 1.62 1.87 30 15 0.92 1.58 1.83 Note: All MPRnozzlo testedon4'(701 cm)pp-ups ■ Squarespoongbosedon50%diameterofthrow ♦ Triangularspecing based on 5M diameterof throw 0°Trajectory Nozzle Pressure Radius Flow psi ft. gpm SF 15 5 20 5 1.50 50 25 5 L 1.50 30 5 1.50 5H-B 15 5 1.00 20 5 1.00 25 5 1.00 30 5 1.00 5Q-B 15 5 0.50 / 20 5 050 dL 25 5 0.50 30 5 0.50 SCST-B 15 5 0.50 20 5 0.50 25 5 0.50 30 5 0.50 Note: Indicates adjusted radlus atpsi shown Note: Nowatadjustedmdiusuf5reet(1.5m) The Intelligent Use of Water.' www.rain bi rd.com/sprays Nozzle Pressure Radius Flow Flow Precip Precil bar in m% I/m mm/h mmlh 15F 1.0 3A 0.60 9.8 52 60 3. 0. 11.8 4 55 O1. 2.00 4.55 0.84 84 13.7 411 48 2.1 4.6 0.84 14.0 40 46 15H 1.0 3A 0.30 4.9 52 60 15 2.0 3.9 45 0.36 0.42 5.9 6.8 47 41 55 48 2.1 4.6 0.42 7.0 40 46 15Q 1.0 3A 0.15 2.5 52 60 15 3.9 0.18 2.9 47 55 2.0 4.5 0.21 3A 41 48 2.1 4.6 0.21 3.5 40 46 Peacamancedata takenin. wimi cwMhions Noonsliedficiptaybodyandnozzles-paratety. Now.Radius reduction over 25% ofthe normal throw of the nozzle a not recommended 0°Trajectory Nozzle Pressure Radius Flow Flow bar m n t 1/m SF-B 1.5 1.5 035 5.7 1.5 1.5 0.35 5.7 2.0 1.5 035 5.7 2.1 1.5 0.35 5.7 SPA 1.0 1.5 0.23 3.8 1.0 1.5 013 3.8 2.0 1.5 023 39 2.1 1.5 0.23 3.8 5Q-B 1.0 1.5 0.12 1.9 / 1.5 1.5 0.12 1.9 c4. 2.0 1.5 0.12 1.9 2.1 1.5 0.12 1.9 5CST-B 1.0 1.5 0.12 1.9 1.5 1.5 0.12 1.9 �4- 2.0 1.5 0.12 1.9 2.1 1.5 0.12 1.9 19 Spray Nozzles MPR Nozzles www.rainbird.com/sprays Plastic MPR Nozzles Models Matched Precipitation Rate Nozzles • 5 Series: Quarter, Half, Full Nozzles • 5 Series: Bubbler Nozzles Features • 8 Series: Quarter, Half, Full Nozzles • Matched precipitation rates across sets and patterns in 5 Series, .8 FLT Series: Designed for lower trajectory applications, such as 8 Series, 10 Series, 12 Series, and 15 Series for even water distribution windy areas and design flexibility • MPR Nozzles are installed by more contractors than all other brands ' 10 Series Nozzles combined • 12 Series Nozzles • Quickly identify radius and arc with Top Color -coded' nozzles even - 15 Series,. Quarter, Half, Full Nozzles when system is not operating • 15 Strip Sedes Nozzles • Three year trade warranty ThesemngesorebasedoopruarPressureomMe. ' Rain Bird recommends using 1800PRSSpuryBodies tomsentain Operating Range optimum rozzleperformamein hgherpressuresituatrons • Spacing: 3 to 15 feet (0.9 to 4.6 m)l • Pressure: 15 to 30 psi (1 to 2.1 bar) • Optimum pressure: 30 psi (2.1 bar)z Rain Bird- MPR Nozzles, The IndustryStandard 5. Trajectory Nozzle Pressure Radius Flow Precip Precip psi ft. gpm In/h In/h SF 15 3 0. 3.. 20 4 0.33 33 1.99 99 2.29 29 O 25 4 0.37 2.23 2.57 30 5 0.41 1.58 1.83 5H 15 3 0.14 3.00 _ 3.46 20 25 4 4 0.16 0.18 1.93 2.17 2.22 2.50 30 5 0.20 1.54 1.78 5Q 15 3 0.07 3.00 3.46 20 25 4 4 0.08 0.09 1.93 2.17 2.22 2.50 30 5 0.10 1.54 1.78 Note: All MPR nozzles restedm 4"(10.2 on) pop -ups ■ SquarespadrigbosedmSO%diam taofthrow ♦ Triongularspacingboedw50%diameterofmrow The Intelligent Use of Water." IR MPR Nozzle and Screen 5F rr Pane n F: call B:Hax Q:Quaner MPR Radus Range 5:5 fen(15 m) B:Bfeet 12.4m) 12:12feetu2m) 15:15feet1.6m) Per/ommnce data taken In taro wind conditions Now. Speolysptaybodyand nozz/esserommly. Note: Radius reduction aver 25%of the normal throw of the nozzle is tat recommended RAIAF BIRa. Spray PR Nozzles RAIN B/RD® Spray PR Nozzles 30°Trajectory Nozzle Pressure Willi. Flow psi ft. 9PRR 15EST 15 4 x 13 0.45 20 4 x 14 0.50 am 25 4 x 14 0.56 30 4 x 15 0.61 I SCST 15 4x26 0S9 20 4x28 1.00 25 4x28 1.11 30 4x30 121 15RCS 15 3 x 11 0.35 20 3 x 12 0.40 �b 25 4x 14 0.45 30 4 x 15 0.49 15LCS 15 3 x 11 035 20 3 x 12 0.40 d� 25 4x 14 OAS 30 4 x 15 OA9 15SST 15 4 x 26 0.89 =mom= 20 4 x 28 1.00 25 4x28 1.11 30 4 x 30 1.21 9SST 15 905 15 1.34 20 9x16 1.47 25 9 x 18 1.60 30 9x18 1.73 t - 30°Trajectory Nozzle Pressure Will. Flow Flow bar m marfi I/m 15EST 1.0 1.2 x 4.0 0.10 1.7 1.5 1.2x4.3 0.11 2.0 2.0 12x43 0.13 2.3 2.1 1.2 x 4.6 0.14 2.3 1SCST 1.0 1.2 x 7.9 020 3A 1.5 12 x 85 023 4.0 SS 2.0 12 x 85 025 45 2.1 12 x 92 027 4.6 15RCS 1.0 0.8 x 32 0.08 1.3 15 1.0 x 3.9 0.09 1.6 MOORb 2.0 1.2 x 4.5 0.11 1.8 2.1 1.2x4.6 0.11 1.9 1 SLCS 1.0 0.8x3.2 0.08 1.3 15 1.0 x 3.9 0.09 1.6 allies 2.0 12x45 0.11 1.8 2.1 12x4.6 0.11 1.9 155ST 1.0 1.2 x 7.9 0.20 3A 1.5 12 x 85 0.23 4.0 4 2.0 1.2 x 85 0.25 4.5 2.1 12 x 92 0.27 4.6 9SST 1.0 2.7 x 4.6 0.30 5.1 1.5 2.7x4.9 033 5.8 2.0 2.7 x 55 0.36 65 2.1 2.7 x 55 039 65 Wm Mithofcoverageperem L-Leaythofooverageporam Perforeancedatatakeninaerown1cordidons Note: Spedfyspmybodyandrroalessepamrely. Noes: Radius reduction owr 25%of f he nmmal thmw of the naak is rrot recommended 5°Trajectory 0 ♦ S'Trajectory Nozzle Pressure Radius Flow Precip Precip Nozzle Pressure Radius Flow Flow Precip Precil psi ft. qpm In/h In/h bar m msA1 I/m mm/h min 8H-FLT 15 6 0.56 336 3.88 8H-FLT 1.0 1.7 0.12 2.1 87 101 20 25 7 7 0.65 0.72 2.91 2.60 3.36 3.01 1.5 2.0 2.1 2.4 0.15 0.18 2.6 2.9 71 62 82 71 30 8 0.79 238 2.75 2.1 2A 0.18 3.0 60 70 111 15 6 018 332 3.83 81 1.0 1.7 0.06 1.1 86 100 20 25 7 7 0.32 036 2.87 257 3.32 2.97 15 2.0 2.1 2A 0.07 0.09 13 IA 71 61 81 71 30 8 039 235 2.71 2.1 2A 0.09 15 60 69 NOW. All MPR nozzles tested on 4"(101 an)pop-ups Performance data taken in zeta wind conditions ■ Squorespacing6asedon5096diometerofthmw Non.Speafysproybodyandnozziesmparat*.. ♦ Tnargularspecingbosedm5096dimneterMthmw Non:Radiusmduttionover25%ofthemrma/throwofONnozdeisnotrecommended 20 The Intelligent Use of Water:' NOZZLE - MATCHED PRECIPITATION RATE NOZZLES CUT SHEET SCALE: NOT TO SCALE 15-Trajectory Nozzle Pressure psi Radius ft. Flow apm Precip In/h Precip In/h 1OF 15 7 1.16 2.28 2.63 20 8 1.44 1.71 ° O 25 9 1.44 1.71 1.26 1.98 98 _ 30 10 1.58 152 1.75 10H 15 7 0.58 2.28 2.63 Aa20 8 0.65 1.96 2.26 25 9 0.72 1.71 1.98 30 10 0.79 152 1.75 100 15 7 0.29 2.28 2.63 20 8 0.33 1.96 2.26 25 9 0.36 1.71 1.98 30 10 0.39 1.52 1.75 ..•, .. �a.wy ■ Nozzle Pressure Radius Flow Precip Precip psi ft. opm In/h In/h 12F 15 9 1.80 2. 2.47 20 10 2.10 2.02 @ 2.3434 O 25 11 2.40 1.91 2.21 30 12 2.60 1.74 2.01 12H 15 9 0.90 2.14 2.47 20 10 1.05 2.02 2.34 25 11 1.20 1.91 2.21 30 12 1.30 1.74 2.01 12Q 15 9 0.45 2.14 2.47 20 10 0.53 2.02 2.34 25 11 0.60 1.91 2.21 30 12 0.65 1.74 2.01 Nota:A/IMPRnordes testedono"(101 cm)pop-ups - ■ Sgwmspocingbasedon50%diamaerofthmw ♦ Triangular spacing based on 5096daimeterofthrow 18 uu)tn.tmy zle Pressure Radius Flow Flow Precip Pn bar m marh Jim tam/h tar 1.0 1.7 0.16 2.8 72 84 O1.2.1 0.23.4 58 68 2.00 2.4 0.233 3.9 48 55 2.1 2.4 0.24 4.0 40 46 1.0 6.08 1.4 73 84 1.5 2.1 0.10 1.7 57 66 2.0 2A 0.12 1.9 47 54 2.1 2A 0.12 2.0 40 46 1.0 1.7 0.04 0.7 70 81 1.5 2.1 0.05 0.8 57 66 2.0 2.4 0.06 1.0 48 55 u-IIa)KtDIy ■ Nozzle Pressure Radius Flow Flow Precip Pit bar m mafi I/m tam/h tat 1OF 1.0 2.1 0.26 4.2 58 67 0 4. 50 58 O1..4 2.00 33.0 035 35 6.0 39 45 2.1 3.1 036 6.0 37 43 IOH 1.0 2.1 0.13 2A 58 67 15 2A 0.14 2A 50 58 2.0 3.0 0.18 3.0 39 45 2.1 3.1 0.18 3.0 37 43 IOQ 1.0 2.1 0.06 1.2 58 67 1.5 2.4 0.07 1.2 50 58 2.0 3.0 0.09 1.2 39 45 2.1 3.1 0.09 1.2 37 43 .zv uu)ectury 0 Nozzle Pressure Radius Flow Flow Precip Precip bar in _ mite I/m _mm/h mm/h 12F 1.0 2.7 0.40 6.8 55 63 3.2 0.48 8.3 47 54 O1.5 2.0 3.6 0.59 9.7 46 53 2.1 3.7 0.60 9.8 44 51 12H 1.0 2.7 020 3A 55 63 15 32 024 42 47 54 2.0 3.6 030 4.9 46 53 2.1 3.7 030 4.9 44 51 12Q 1.0 2.7 0.10 1.7 55 63 1.5 31 0.12 2.1 47 54 2.0 3.6 0.15 2.4 46 53 2.1 3.7 0.15 25 44 51 Per/nrmancedmo taken N zero wind caMMons Non: Specify spray body and nozzles separately. Non: Radiusmdudion over25%ofthemmal throwofdre nozzMts mtreoornrnended The Intelligent Use of Water 17 k Tech Spec 1800" Series Spray Heads2. � �a 1ROOSAM-P45Series U=_ Z Meets the the needs of spray body applications �L using Rotary Nozzles regardless of changing UJ UJI 0) 66 elevation orwater pressures. Incorporates Z I.- LLI 1800 Series SAM feature and regulates oper- Bring pressure at45psi(3.1 bar). UJW O 2 U O U l om • Designed to maximize application C0 Z W Z YUr H W 5; U) - efficiency when using Rotary Nozzles. i-- W Q 2� W Z g a • Maintains constant outlet pressure at II Rain Bird" co -molded, �J > Z U W 0) O w 45psi (3.1 bar) at varying inlet pressures. - V pressure -activated U) 5 2 Q Q Z Q Maintains constant pressure regardless of 14 _ Per seal Z rn 2 W Z_ F how nozzle used. CL Z Q Q Q~ O o"m • 'SAM identification-PRS45"stamped on capforeasy Q U d identificationandand maintenance. Z 07 W Z < p • Five-yeartrade warranty. Q I Z d a� a- J J Operating Range U o p • Spacing: 13 to 24 fee (4.0 to 73 m) W bg • Pressu25 to 70 psi (1.7 to 4.8 bar) Strong stainless steel O z & re: retract spring 0) Q Specifications = g • 45 psi (tes nozzle w pressure to an sunsaverage up o $a 45 psi (3.1 bar) with inlet pressures of up to 70 psi (4.8 bar) - • SAM capability: holds up to 14 feet (4.2 m) Side inlet on 1806, of head; 6 psi (03 bar) 1806PR5, 1812, and • Flower: 0 at 8 psi(0.6 bar) or greater, 1812PR5 models only 0.1 gpm (0A2 ma/h; 0.0061/s) otherwise , REVISIONS • Installation: bottom inlet only DRAWN BY REV DATE COMMENT cecxeo HECMDB DIIIIenS1Oi15 s� er • 1 10/29/2021 PER ISP COMMENTS DSH tit"(1521)NPTfemale threaded inlets RTY • Body height: 1804 SAM-P45-6"(15 cm), PER COUNTY BSC 18065AM-P45-91§"(24cm), r Patented FIRS in -stem 2 01/21/2022 1812 SAM-P45-16"(40 cm) COMMENTS RTY • Exposed diameter. 2y4(5.7 cm) I pressure regulator PER COUNTY BSC option 3 04/08/2022 COMMENTS RTY Models • 18045AM-P45:4"pop-up height (10 cm) • 18065AM-P45:6"pop-up height (15 cm) • 18125AM-P45:12"pop-up height (30 cm) 1806 with Swing Joint on Bottom Inlet 1812 with Swing Pipe on Side Inlet Specifications 1802,1803,1804,1806 and 1812 Pop-up Full or Part Circle Spray Sprinkler The sprinkler body, stem, nozzle and screen shall be constructed of heavy-duty, ultra -violet resistant plastic It shall have a heavy-duty stain- less steel retract spring for positive pop -down and a ratcheting system for easy alignment of the pattem.The sprinklershall have a soft elas- bomer pressure -activated co -molded wiper seal for cleaning debris from the pop-up stem as it retracts into the case to prevent the sprinkler from sticking up to minimize flow -by" The sprinkler shall have a matched precipitation rate (MPR) plastic or brass nozzle with an adjust- ing screw capable of regulating the radius and flow The sprinkler shall be capable of housing protective, non -clogging filter screens or pres- sure compensating screens (PCs) under the nozzle The screen shall be used in conjunction with the adjusting screw for regulating.The 6" (15 cm) and 12"(30 cm) models shall have both aside and a bottom 12"(1521) (FNPT) inletfor ease of installation. The sprinkler shall haves Pop -Top Flush Plug re -installed. The plug shall prevent debris from P P 9 P clogging the sprinklerduring installation and allow for the system to be flushed before noz- zling.The plug shall be bright orange in color and constructed of polypropylene material. Rain Bird Corporation 6991 E. Southpoint Road Tucson, AZ 85756 Phone: (520) 741-6100 Fax (520) 741-6522 Rain Bird Technical Services (800) RAINSIRD (1-800-724-6247) (US. and Canada) a Registered Trademark of Rain Bird Corporation e 2009 Rain Bird Corporation 10109 RARD. 1804 SAM, 1806 SAM and 1812 SAM Full or Part Circle Seal-A-Matic"Pop-up Spray Sprinkler Optional Feature Specifications: When so indicated on the design, the 4, 6" or 12" high pop-up spray sprinklers shall also include a Seal -A -Mack (SAM) check valve to prevent low -head drainage of up to 14feet of head. This feature shall require the use ofthe bottom inlet only. These units shall be identifi- able from the top with "SAM"marking on the cap. The sealing device shall be an integral part ofthe pop-up stem, removable through the top ofthe sprinkler, and shall seal against the bot- tom case inlet It shall create no more than 1 psi pressure drop at the maximum rated flow. 1804 PRS, 1806 PRS and 1812 PRS Full or Part Circe Pressure Regulating Pop-up Spray Sprinkler Optional FeantreSpecificotions: When so indicated on the design, the a, 6" or 12"hlgh pop-up spray sprinkler shall also includes pressure regulating PRS device to P (PRS) re9 9 prevent high pressure fogging to the nozzle stream.This regulating device shall be an integral part ofthe pop-up stem, removable through the top of the case. These units shall be identifiable from the top with "PRS" markings on the cap. The device shall regulate the nozzle pressure to 30 psi for inlet pressures from 35 to 70 psi. Below 35 psi the pressure loss shall not exceed 6 psi. Rain Bird Corporation 970 West Sierra Madre Avenue Azusa, CA 91702 Phone: (626) 812-3400 Fax (626) 812-3411 Specification Hotline 800458-3005 (U.S. and Canada) 1804 SAM-PRS, 1806 SAM-PRS and 1812 SAM-PRS Full or Part Circle Seal-A- Matic Pressure Regulating Pop-up Spray Sprinkler Optional FeatureSpecifimtionz When so indicated on the design, the 4", 6" or 12"high pop-up spray sprinkler shall also include a Seal-A-Matic (SAM) check valve and a pressure regulating (PRS) device. These units shall be identifiable from the top with "SAM- PRS"markings on the cap. The check valve shall prevent low -head drain- age of upto 14 feet of head.The pressure regulating device shall prevent high pressure fogging ofthe nozzle stream by regulating the nozzle pressure to 30 psi for inlet pressures from 35 to 70 psi. Below 35 psi the pressure loss shall not exceed 6 psi. These models shall utilize the bottom inlet only. 18045AM-P45, 1806 SAM-P45, and 1812 SAM-P45 Full or Part Circle Seal-A-Matic Pressure Regulating Pop-up Spray Sprinkler Optional FeatureSpecifications. P When so indicated on the design, the 4; 6", or 12"hi h s sprinkler shall also 9 poP--M Pray P include a Seal -A -Made (SAM) check valve and a 45 psi pressure regulating (P45) device. These units shall be Identifiabiefrom the top with "SAM-PRS-45'markings on the cap. The check valve shall prevent low -head drain- age of upto 14 feet of head.The pressure regulating device shall prevent high pressure misting and undesirable performance ofthe nozzle stream by regulating the nozzle pressure to 45 psi for inlet pressures from 50 to 70 psi. Below 50 psi the pressure loss shall not exceed 6 psi.These models shall utilize the bottom inlet only. The s sprinkler shall be as manufactured P by Rain Bid Corporation, Azusa, California. Rain Bird International, Inc. 1000 West Sierra Madre Ave. Azusa, CA 91702 Phone. (626) 963-9311 Fax (626)852-7343 The Intelligent Use ofWater' www.rainblyd.com SPRAY HEAD - 1800 SERIES CUT SHEET CONTINUED SCALE: NOT TO SCALE D39025K fizzle • 1 Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL ANDIOR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: LSCP -2 PROJECT: SITE PLAN DOCUMENTS FOR DISC®C�7aQ PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA22901 0 B0 HLER/ 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA 23146 Phone: (804)893-8200 VA@BohlerEng.com �,pLTH OF QNICHOLAS T GEO GAS Cert. No. 001653 7?'� U 8/27/2021 scq PE ARG� SHEET TITLE: IRRIGATION NOTES AND DETAILS SHEET NUMBER: C-711 REVISION 3 - 04/08/2022 +0.0 +9.0 .0 +D.0 11 ++a.t +0+1 9.1 +9.2 +0.4 +0.3 +0.1 +0.2 +0.3 +0.4 +0.3 02 CALCULATION SUMMARY CALCULATION ZONE AVERAGE MAXIMUM MINIMUM MAX/MIN PARKING LOT 1.3 9.5 0 NA PROPERTY LINE ADJACENT COMMERCIAL TENANTS 0.1 2 0.7 0 NA PROPERTY LINE ADJACENT TO STREET 0 1 0.1 0 NA SITE 1 1 9.5 0 NA ALL LEVELS ARE IN FOOTCANDLES, ALL LUMINAIRES CALCULATED USING 1.0 LIGHT LOSS FACTOR +OA +0.8 +0.8 +1.1 _ 1A +. 1.1 fos + 0.2 1 Q HS 3 EACH OUTDOOR LUMINAIRE EQUIPPED WITH A 0.1 LAMP THAT EMITS 3,000 OR MORE INITIAL as +' 9.6 + os + ,.1 + 5 +1' +.6 2.6 +' 2.8 + 12 + LUMENS SHALL BE A FULL CUTOFF AND SHALL °-t PROPERTY LINE BE ARRANGED OR SHIELDED TO REFLECT LIGHT AWAY FROM ADJOINING RESIDENTIAL DISTRICTS .6 AND AWAY FROM ADJACENT ROADS. THE 4PA +9'6 4P.9 +1.1 +1. +1. +,.9 +2'2 +2.6 +2A +1.2 +' 0.4 SPILLOVER OF LIGHTING FROM LUMINAIRES ONTO ° PUBLIC ROADS AND PROPERTY IN RESIDENTIAL ° OR RURAL AREAS ZONING DISTRICTS SHALL NOT +°'1 +°'a +9'6 +1'1 1 1.5 +'6 +2'° +2'1 +2'1 +1'e +1'6 +°'7 3 EXCEED ONE HALF FOOTCANDLE. 02 MAX HEIGHT OF POLE MOUNTED FIXTURES, WITH BASE, SHALL NOT EXCEED 20 o.0 9.1 o.z 1.1 1.8 1.7 1.6 a 1.5 1.7 1.7 t.a v 95 0.1 1 +0.0 +0.0 -19 , +02 +1.8 +1. +1.8 +1.3 +0.8 +0.8 +1.0 +1.1 .9 +.8 + 7 .7 49.5 +0.1 0.1 .,► +01 + + + + + + + + + + + + + + + t + + +' 01 , f0+0.1 +0 4-1.9 +F8 +1.6 +1.3 +0.8 +0.5 +0.5 +0.9 +1.6 +2o +3.3 +3.3 .1 +3.6 +1.3 +0.2 H0.1 +01 +0.0 D 8 5 0.8 02 0.0 +0.1 +12 +12 1.2 +1.0 +0.7 +0.6 +0.9 +1.7 +2.1 +4.2 +3.8 +3.8 + + + +' +0.1 +0.0 0.1 .8 D8 _Ij0.8 0.7 _Ij0.9 15 _II23 41 ii5 49 .4 1.0 D5 0. 01 +0.1 +0.1 49.5 +o. +0.7 +1.2 +2.0 +3.9 +4.3 +4. 0.6 +0.6 +0.5 +0. + . +0.1 3 +0.1 +0.3 + .4 or 7 +F3 +22 +3.1 + OF 0.8 +1.1 +a. % +' +9.2 +9.0 +0.2 +D.2 0.3 0.5 +0.9 +1.7 2.8 +2 ° 1.9� +1.8 +1.1 + +Poo +O.Y +0.3 + +0.8 +1.3 +1.9 2.3 +2.5 n 3.5 +3 0 +0.9 + +9.2 LJ 0 U LL IE +D.D +0.2 _fPA 0.6 +1.0 +1.G +2.4 2.7 DV 2.6 41 3 +0.5 +0.0 +0.3 +0.5 0.8 +1.4 +2.0 +2.7 +2.7 +2.8 +1.4 +0.8 +0.3 _ +0.1 49.3 +0.1 +0.6 1.0 +1.4 +22 +2.8 +2.a .0 +0.5 +0.3 +0.2 +DA +0.1 +DA +0. -Ft 1 +1.6 +2.1 +2.7 +2.5 +2.6 +0.1 +0.1 _FD2 +0.2 +0.2 + +0.1 0.1 -04 +0. +1.1 +1.s + +2.4 +2.1 O +0.1 / .1 + +0 +DA +0.3 + +94 1 2 +0.1 Q +0.5 + . +1� + 3 +7.6 +1.8 +7.3 ° .2 2 0.1 .1 +0.3 0.6 +0.6 +0.6 +0.5 0.3 + 0.1 +0A a O 7v/may +0.0 Q 04 OB 1.0 1.1 0 •9. 2 0 07 7LY 11 09 04 03 00 0 0.0 4D3 + +' + + +' 4 Atl°' + +' +' + +' +' +' +' +' +' �' 00 49.3+oa + +O.s +O.s +o.s +o. +0.1 +o. 0.3 +12 +1.7 +.'1.6 1.3 +. +D1 +o.a .0 +0.2 +0.3 +0.4 +0.3 +0.2 +0. +0.1 +o. _ll +7.3 +1.8 +2.0 +1.8 +IA 1. +0.1 +G0 +0. .0 +0.2 0 +° W.2 +0.2 +0.1 +0.2 + . + .7 +1. +1.8 +2.1 + +2.6 +2 +DA +0.1 +0.0 G o +0.1 +0.1 +0.1 +0.2 +0.4 +0.7 +1.3 +7.7 +2.0 3.2 +7.0 +0.3 +0.1 1 z�QG� / +9.1 iC QHS 5 0.7 0.2 04 07 1.1 15 17 1.2 OS 02 7 (9 +0.1 Jv 0 +0.1 +D1 +oA +& +.B +1.0 +1.4 +0.7 +0.4 +0.3 ^O +0.7 .1 +0.2 0.4 +0.6 +0.7 +0.1 +0.2 +0.1 +0.1 +0.1 .1 +0.1 +0.3 +0.3 0.1 +0.1 +o.1 +0.1 +0.1 .0 + .1 +.1 +.0 +0 +0.0 +0.0®� +.0 + .0 +0.0 _FDo +OA .0 0 SITE PHOTOMETRIC PLAN +0.9 0 +° 0.0 ++ 0.0 0.0 SCALE: 1:20 + .0 }+%.a NO. REVISION DATE . ARCHITECTURAL RESOURCE TEAM A" 4 GO STAM P CONSULTANT . Dialectic ENGINEERING Dialectic, Inc. T 816-997-9601 310 W 20th Street, Suite 200 F 816-997-9602 Kansas City, MO 64108 DialecticEng.com Virginia Certificate of Authorization Number 407-003805 Copyright 2021 1 CITY COMMENTS 08/24/2021 2 SITE UPDATE 10/20/2021 3 CITY COMMENTS 01/17/2022 KAD LED LED Area Lumini Specifications { EPA: 12k] Length: ,7-I/2" T ill Wldwn 11.12' IH Height 7,118, u:, . WWBL (-N*� i 3albs. mutp i.• . KAD LED 40C 100040K R4 208 Hs I r� �Na1., frQ11S "t, Capable Luminaire Thrs item is an A� capable luminaire, which has been designed and tested to provide consistent color appearance and system-leve incomparability. • All configurations of this luminaire meet the Acuity 13rands'specification fair chromatic consistency • This luminaires A* Certified when widened with DTL• controls marked by z DTL DLL equipped luminaires meet the Aa --s rtfirarrnn fnr hrminah. to Mhn ncommil providing out -of -the -box control compatibility with simple commissioning, when ordered with _ driven and control options marked by a. To learn from about A., visit wvvlwaa,uc4bran�. 1. See ordering time for details. 2. A+ Certified Solutions far iOAM require the order of one ROAM node per luminaire. Sold Separately: Link to Roam'. link DTI DLL A.tMtlarrulrtuModl to bdawHdAmtut • EXAMPLE: KAD LED 40C 1000 40K IRS MVOLT SPD04 DDBXD DruO � Were M' MIN 50 Status' Me RSad Al ["I MYMP 217' sh"WedtaN Situp( Sop awy ME MIN ]act meth Oat *)AK M mete us, "it SRMII[ S4unpN,nwul moiw.rq M.rw M 1"arm Melx Rtn-ram 40C Will Mal Miami ME SO101 14 1,111 al" qi VLWU_ Rouk pe4,m,nul moun'.mg w+Nn M n"arm r,* ME HIED, A3 1"V 20'• SFD_ 5a++npah 03 0"arm• MD11W1 Rei!eani IW_ R9uadwit I] 12'nm' Mee_ WIMIt" pA1 rni �a,n two_ woodisew.A a.i.�i 91pyedsgmM .--SbiWdlwtdkA Falls ABMbeyDtlhaweglOdtMO pMI3 M IWI,n6rnYdlrarMMee 11YIM3 PMgrsdimtill W Wri Odeonblul 615rtoaealada miters dmn"" ' � M,e 14lM�ks`aliiae4ad51 t" IM'Y a MHI503 ydll flg'P.Ilm SF vyxPmo l'.1a, 117,NR'I' _ _---- - pMxIR3Y SW'" 15 RimwrNmigh obi 15331nemn0MMtmr PWM Pala Jim a Dadklux 008,240,4DN1' xrm er40kdx 1h-•"•" 6M, pie M-IM"'Wel l ermta-t5'annrq MUD BHrr11':W m¢ " iF HYr1N Finn dim "' hgk arbNnwenarWd4Sh".•••" IM,19 PMX OIAad.ndawmkpt letetlSlOmoebg MSo BFIrrl wuAeebmeq M xueelkick nslptmsreaaineelkaa5h-""" 50b""• -fA L/fY'1GN/A one lxnarn. Von,Von,• ewken, Gerrea 3012. ftene amP9 call - L/LPN77NG om11-m1aAw.per,w.yn'ey 1.<er.gr..«w.d Series Size 1 DSXW ILED10C700030KTFTM720DDBJLQ LED Wall Luminaire�i rlicn �T"• DFDF d'series Introduction Specifications The D-Series Wall luminaire is a stylish, fully Luminaire Back Box SEW, ELCW) integrated LED solution for building -mount Width: 133W TWPlyhe 12IFs eYli 133/4' am 5ba applications. It features a sleek, modern design .....,I %"ht airs, D.pth: 10. Depth. 4- ELCW and is carefully engineered to provide longlas¢ng, .. Weights�49� energy -efficient lighting with a variety of optical Height a RB' HeIEM: 6 3113 and control options for customized performance - With an expected service life of over 20 years of ° nighttime use and up to 74% in energy savings Rr � �) over comparable is a re metal halide luminaires, will Me D-Series Wall 5 a reliable, low -maintenance w Fm Y4' Nit edac,v, lighting solution that produces sites that are r....d.n mew odrl exceptionally illuminated. • EXAMPLE: DSXW1 LED 20C 100040K T3M MVOLT DDBTXD again us 05AW1 LED a ILIIt 350 35o mA mA KODr 125 tylnum. MVXI' SMPPdin,udd Sh9rdini Ica 510 511 Me imor fist Tne0t4drn in' curs, `o b,r K PAdMntM,dLbiAlmlpk' xgne, MO )ri Sax Stet, En TIpellvnt M. nae"I OY0 D10+ImmegmnwledvWehowlb %x `oEO, Pow pass 1Dmm4eu A1MK hmp,. TIM T"Inquebm 240, biwsn uNtuaarainslowd.ode"nowd5l gnnl �' 11M 11yery Msdutu 271' mPww I/Pml,a7aremiMr cactus, <15'mgM" r RIM rwvad Nn 347" bu5hn PMx I/VmIM/arYnlgM llllet lSiaiagk'' MMrn ME" lo,Pdm, PMIKW hblalMbmSrietl-IS'Iwde9teQit «u. rl' mHed vein eulktlx lk- PMH1Rn Momiarbrgsrlmel5-3D moeolq M9K mMrnwrnellalal4lk' Bra ceiaomt eL(Y14T�ip NxmiMYAa' tswHN�5m0ffin.".neel, Di 3 Dsm saldme MMO Tmed Mite 9 vigk Na11 a11na v. 1 I, DDM tneMlYReaa amTmuea anaeue InoaNrrwlwx.rovu.. A DUND D:I �� ii DB.pD Imaebxd K Ica wNNe Da rt:^r,:n: ^n'. pNl® 15Yr an= rnmaen ame. Sm vpaoe ugredearn DMe Olnbiurrr `1 Immard, rapes t•Pat I X1C la]In,w °wrW .11,lAI. A11l flAlr{ely RllfOV DMMm uaurel DIIMM fnuedbWt °iYie•"a•fl°i°•-�'• a vutarcraperesea ewwerelaOe Mntmamaarolm. Juninum DMT.e Tauwmlvi ewy. I„c°eeyrP t S.sYh-fftnMmlal, w7v W-Iyg,wa.Dwtlrrwrpa'ww.,mtYav40.aly.p- a'R'a°^ rl^•P•1 s »�.r ae w�drf wneToflaeee MWID wvt, seism m�Rm~.e fbe ne�..�.r DMHW koodge rnvlMru •1'rha,.rww a IN.wm..a lltnlrwm.lm,mcaw. n7wwd r4inv MN er4M,+.M1mnaY.r4nt hpNra-nMnrell gYlSa wlww•am, 1 a.lw�•Ka 3vrovEb o.tvyd 6 call ciOo'.lpi nm•Y•.M.m.Wr�w.r<m. Wn.ib•.tl.aM'^>nwg,pb�Nn w.WI,uA.4,^9 xn,rW...ln vtl0 •a.wa-.. I'nar,.Y m'•w-*Ia..d..e.sa°.I.w 9.7..,..4.rsp.l,waw.t•mev.w.u<�_.._. . nw.rsh.asro. 10 rlu•,ei,bM cad QCNt n aw.r.w.-.'vw•.®n..4r�i..fva,nmr u Na.arW,.iM.¢cw "'D ton 1,1, 0 fall, D-Series Size 1 I ""''c°e'r DSXWILED10C100030KnI11120DDWID LED Wall Luminaire f N-' Tr i, oW d`series Introduction Specifications The D-Series Wall luminaire is a stylish, fully Luminaire Box (SSW, ELCW) integrated LED solution for building -mount WdtK 13.3W Weight 121:., Widtn: 133/4' DBW 5lbs applications. It features a sleek, modern design :c... ru....; Weight >vai and is carefully engineered to provide longlasting, o•pitht' ss �l �Mt' 1mz,4,.1 9y�hb Ira„�s1 energy -efficient lighting with a variety of optical H.Folm 6310' 6313' and control options for customized performance. un7-.n1 fill. With an expected service ife of over 20 years of ,{° W nighttime use and up to 74% in energy savings r over comparable 250N metal halide luminance INAII j`��\ b the r comparable Wall is a reliable, l halide luminaires, yy pwv.•Nr7 m.cNY lighting solution that produces sites that are m,a,n mew oleo exceptionally illuminated. • EXAMPLE: DSXWI LED 2DC 100040K T3M MVOLT DDBTXD ovanLa MMLED ME 101fR 350 350md 3M i'to, Us Tnei MVXI' 9ippedilwMdd 9irRdimtasd are M 5IDmA Me loco, 111111 T,1114edrn U01 (Wall Sstae For Malwhrm ¢II, bEC irye' egad Me M0,vk SG uIns In Tp Ms+wt M, muwtlq 0M0 Dtp 4mmngmr Ws/wArdesawlb 3K 201% In.Ur wwxMnmWaald.otledxMMtlyl x.r No 1aillaiU AMOK Xmpr. let Tp,Ilwal No' xgnd men' T4M TrM IYliedam 2771 HM �Slaaineed M IBPwplroleira it lrr xravn <tSmgM TFTM hawtl Trrp. 171,billion PMx IaTmiaNamMar lrt xrMtlS.NiMq M" I Wlaui PMIIC3Y Abbalmbmisensoi8-15'ioccur,wd't wor,l, Mlbarlsaem enadwalk MNIK3Y hbtulambmnrrDr l;9tl irrimyagM MMen lwndi alrNM a Ih' Elm Fmelq•nry ban%Maw la'aMmxiN' ,1vgrnm: a+m..rr; s'm v1',nenNan'. sell central We MD OM�D D•rtum_, DsLID Seiand. am" hnaedwhte 5f �ngly fusllm.maHM"' M oi44netnln,Hles DD= Nraedalbrost MT" Ie[ual SanMrwc DF .buwe laelM6,leorMW1"' V6 vtudaliyud OXA1p 440dic'.11 as RKD odoneiaxd M ndulrwr x.red m LMMxdlkakm wMOM YaP DN41X0 T-nan,ealdllrmn W 5,gaa[e agreda7m- Accessories notes 1 sit teto nW w�lcl•v11.A1.nMtflnrQ'vrR,IfOY o�r.Y� �� a MAl76rrta <OwmlanpFewinYMnImSFNeP,Orle. d s.yrsmne.n,ta,,m.dewas.•pewDew.•+rlDanlumaw.7wval4..dtq,ap- mien nrrrralrn ,r„� l dl,adfbwd Ai.aL.AulabM. Nor aafibb W.rPOMX. m6Vn NM.-aY. S a.46u,Apewlkd onbm,e! befddwirdC 6e.,eaees�®,r 4 R,eb,wMlfF nyn,lS, Efl 310,D]vH]gb}gbrNelwLXw M.maeNer4i•i14k�a,Pew Wnl. m1<Y aeMwwaam, 1 P.fws.awnm 5wrontb enp pl 4 Gidrtlw 1.mL3.,W N4v+'PeM.•MF rnNrrwl WF<mr Nor,wiMrwF9aV non>9Mnn Wr.nWIvwMWW IH.uli3.+rh 31]vYe .auy. m..n un..an.X �.w-u aaN nbvYb•. b,-q rnwP..7..a. fs n. i.wd-r•.dMwsw_.___ .�.•� Ns •w1YL wai sPe. i 10 ian,w3,bh cad ftay. It 4Lo,r.W,,,,,,,aae,rcmr. re. Mnm�,Hwmm• R xaweY.w 6uw '. L/TNON/A One uPen,a war•caryrva.ce°rea 3Muwe •,a1a0o-o 7WSERf U37M .,,,,..1:....',.. mw3ED _ L/GN77NG 0"13.a7m 4uny tuned, gas i-wings, mw..a s. 20"re coMxXncvu wriwon X fL/7NL7N/A ova urtetaww • emw.a.eeama3ml: •nine. 1aW705sEM p37M • :.. N9psnT3n _ L/GN7/NG emismm 4w.,yer...d, .qn.,q iK ul,;gm...,w..e ro. uum ClYlMfer.ILLGRDOJP Doctrinaire Type: got h a m I E V O- /\ Catalog Number: ® C-LDD-120-GZI Multiple Layers of Light E Ak ra Feature set • Bounding Ray-optpal design 2.5 SDCM: 85 CRI typical, 90. CPI optimal Unitized opticsmCtianically attach the light Flwures are vat titans,, cowed ceiling engine to the law rdkcta for complete opi Available with 10% dimming, 1% clim ,or cal element dim to dark • 45• cutoM to scarce and source Image Batwing distribution with feathered edges • Fully serviceadle and upizadeable lensed LED provides exit illWnlnMbn on homfor land light engine Motion surfaces 70% lumen maintenance at 60,000 hours ENERGY STAR -ratified pr.&.t DlstrBbNipn aa3owim A alnn coma Aaedin°IY AL .inn O.5sw o7SW 09SdH 10s.MN I1SYH Superior Performance Pi j1.P z F� 2% 6,00Orinins; r w ��� 4111 I11•' 1�e loans-v.so9xr.tua xmird 250 sold 15D 1000 1500 Mass 2500 MCI 3RID MIND 45MI Saab BOm ® l4m l2 IS,MO 17,SM ainnm 041 A7 539 771 994 3471 )Da 35v W77 351E MET alas 57% 071 rr4/ 1*37 UB3 15715 17MI tanm annual 3e 62 42 9.6 14.7 M7 24.1 29.5 334 360 413 02 57.6 n.1 9.1 IL50 150.9 1753 l-t RI 1137 94y 1035 IH.1 ilia 102.1 IM3 IHa 103.3 Till lW3 1106 ]]at ins IW2 loss HIS pr 6he Coordinated Apertures I Multiple Layersof Light nGeneral lllunilalion Lando I EYD OHier Evans, Beam Latin ll recto M. lute 'I Lett Core r T 4 1 D 111c I W-1o" moX anal Moral cletr rend, line, etwnre.- ahYnli mr,h Healthcare at let an Hx' P.Tmi Special 4 y O Applications Draer 1m 5me, Yardarms, pr-Itun Lae svavatu EVIM." L,3m0 I'IMASS (73M 16an4n13Mmedm �, Daeeld9 - Martin seasoner, ,iiyaanew "con loons, EXTERIOR LIGHT FIXTURE SCHEDULE FIXT. TAG DESCRIPTION MANUFACT. CATALOG NUMBER LAMP BALLAST VOLTAGE WATTS MOUNTING LUMEN OUTPUT NOTES SURFACE LED WALL PACK - FORWARD DSXW7 LED tOC 1000 30K TFTM 39W LED OF LITHONIA INCLUDED 120 39 MOUNTED 3,873 THROW 120 DDBXD 3000K ON WALL SURFACE LED WALL PACK - WIDE DSXW7 LED 10C 1000 30K T2M 120 39W LED DW LITHONIA INCLUDED 120 39 MOUNTED 3,512 DISTRIBUTION DDBXD 3000K ON WALL Iii LED E2 LED DOWNLIGHT GOTHAM EV06-30/07-PR-MWD-LSS-120-GZ1 INCLUDED 120 15 RECESSED 750 3000K POLE KAD LED 30C 1000 30K R4 208 HS 1D8W LED QHS LED POLE LIGHT LITHONIA INCLUDED 208 108 MOUNTED 8,392 DDBXD 3000K @ 20'-0'i 1 1 1 DISCLAIMER: THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF DISCOUNT TIRE COMPANY AND SHALL REMAIN THEIR PROPERTY. THE USE OF THIS DRAWING SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT WAS PREPARED. PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH. 1636 SEMINOLE TRAIL ALBEMARLE COUNTY CHARLOTTESVILLE, VA 22901 STORE NUMBER: VAC 12457 PROJECT MANAGER: PREPARED BY: PH: (816) 997-9601 FAX:(816) 997-9602 DRAWN BY: RMC NORTH TRUE THIS SHEET IS PART OF THE CONSTRUCTION DOCUMENTS, OTHER SHEETS INCLUDING SPECIFICATIONS APPLY. THAT SHOWN HEREON IS SCHEMATIC IN NATURE AND NOT TO BE USED AS A SHOP DRAWING; THEREFORE, INCLUDE ALL MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENT AND MATERIAL USED. VERIFY LOCATIONS AND DIMENSIONS OF ALL ARCHITECTURAL AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPECTIVE DOCUMENTS, THESE ELEMENTS ARE SHOWN FOR REFERENCE AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION AND THE ENGINEER ASSUMES NO LIABILITY FOR THE ACCURACY OF THESE ELEMENTS. NO DESIGN RESPONSIBILITY IS ASSUMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONAL ENGINEER HAS NOT SIGNED AND SEALED PER STATE/PROVINCE REQUIREMENTS. SHEET TITLE: SITE PHOTOMETRIC PLAN DATE: MAY 2021 SHEET NUMBER: C-711 OH BURNISHED CMU 26 -0" T.O. PARAPE OM CONCRETE 16'-8" B.O. METAL OI BURNISHED WALL MTD. LIGHT FIXTU' 0'-0" FIN. FLR. OP WINGWALL T SWITCHGEAR FROM CTPI"GT UPW A 60'-0" <9>ROOF-MOUNTED MECHANICAL EQUIPMENT METAL CAP ON WEST ELEVATION 28'-0" T.O. PARAPET (BEYOND) )MPOSITE 'OND) O DMPOSITE (OND) O )LLARD OK aL DOOR LO pO ALUMINUM COMPOSITI PANELS 28'-0" T.O. PARAPI QOROOF-MOL MECHA EQUIP OALUMINUM COMPOSITI CANOPY 12'-0" NV T.O. STOREF Op ALUMINUM COMPOSITI PANELS 0'-0' FIN. FLR. OB ALL SIDES .,1 „ "UV„ ALUMINUM COMPOSITE PANELS 60'-0" oV11 JVIINI JIVRGr RVINI JIJIGM\V/ ra- Ivl III v i v.vnn v.. II_\�� V CANOPY V EAST ELEVATION • iii iiii • _ _ ` `?=•Iw�wwTww�■•r _ -_-_ __ _ _ _ _ --_- _ _ _ __MMM ___ __— ---� - • wi/� ilw�■—% wwi•-i•=I-==ma —__ 1 wi/�w►i�iiw �i�iii�=_wi■moxmm=1ri11 __ Iraww—i•� mma =�w■i■—iiwww ==ilii.l—�=� Oi • - • wi'�• �w■•ww�rwwwrww ■ww■ w-w/ awe w�•www.i -wa/wl/wwwwwwl -a• ---r —rw I —NMM —a�> -O/mow • : • • ww■a'atwwww�r'wa�wwwtr •wl wwwang-www�wwww wwwwwrw/1�ww-i�rww-- =w' —_--�--- �i=ww-- w� psi �� • ■um-w r � www ww ww own immo1 111—rrw�ww—rwwww wr w-/mm —mol•rm we 1— r�rrwwwwwwrwwwrwww/�ww■•rwl ww rwww wwwwr�rwwl-w■�w/ ww- O • • • • • MMYA ■��w-www wwwwww iwwwwww www -w�� � /wwww wZrwwww �- =_ � • • wwwwwww w www • :ww�ws� ��� • O wwwwwwww awwwwwwww w wwwwwr • © � wwwwwwwww &wa==ww iGiT wwwwww www „ ww=ww c ;;; - • • • • •' 0 w11'fwwwTii�w / I wTiTww� rs Cil � ��iiii�• �rw • • • • - awwmw�s www � -wwwwwwww www • I awwwwwE —www.,�in,llr, .rww wn� — e--- .-- ��...�a...,.a...® �.m..r®....�s� ". _.. • • �����w�-i�� PIMMuwwwwwwwwwwwww��l����•�����It wwwwwa/wwwwwwwallwwwwwwwwwwww�w�w••w�■w�rmmmm�w-Iw_www-Iwwwww�wwww_www-Inilwwww ���—�—� ��w��•'�w��� �R° - www- w�iwwwwwwwwwwwww- wwrww�- �wr-w wwwwwwwwwwwwwww�www-iwwww-iwwwwwwww--wwwin ww win=�w•■�r. www■i�ww r www•■www�- -Iwwwwwww ;` -- - - - - - - - - w w w w ■wwww w ww ■ ww ■ww • • • O C ■ • , �• • • I 1 I I � I'l I I I � I • • •• •• • •• • •• • •••• •• •• •• • • • • •. •MIAMITIF — METAL CAP < T.O. PARAPET , BURNISHED CMU < 12'-0" t\ 0. STOREFRONT �1 O'-0" OL FIN. FLR. JGWALL TO HIDE OP SWITCHGEAR FROM STREET VIEW FINISH LEGEND < 3-DIMENSIONAL ILLUMINATED SIGNAGE OB ALUMINUM COMPOSITE PANELS: ALUCOBOND "MATTE BONE WHITE" OALUMINUM CLADDED CANOPY: ALUCOBOND "MATTE BRUSHED STAINLESS" OD ALUMINUM COMPOSITE PANELS: ALUCOBOND "MATTE BONE WHITE" OE 8" METAL CAP BY ATAS INTERNATIONAL INC. COATED: "BOYSENBERRY" OCORRUGATED METAL PANEL BY ATAS INTERNATIONAL INC. COATED: "BOYSENBERRY" O STOREFRONT CLEAR CURTAIN WALL BY C.R. LAURENCE "3250 SERIES" STANDARD GLASS WINDOWS. NOTE: VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED 30%. OINTEGRAL COLOR BURNISHED CMU BY GRAND BLANC ARCHITECTURAL MASONRY "S.E.D. BLEND" - MASONRY BLOCK SIZE: 8"X8"X16" OINTEGRAL COLOR BURNISHED CMU BY GRAND BLANC ARCHITECTURAL MASONRY "GARNET" - MASONRY BLOCK SIZE: 8"X8"X16" OJ CLADDED STEEL BEAMS: COLOR TO MATCH GRAND BLANC ARCHITECTURAL MASONRY GARNET" OK STEEL BOLLARDS: COLOR TO MATCH GRAND BLANC ARCHITECTURAL MASONRY "GARNET" OL HOLLOW METAL DOORS: PAINTED TO MATCH GRAND BLANC ARCHITECTURAL MASONRY "GARNET" OCONCRETE CAP: COLOR TO MATCH GRAND BLANC ARCHITECTURAL MASONRY "GARNET" OMETAL CAP: COLOR TO MATCH GRAND BLANC ARCHITECTURAL MASONRY "GARNET" OO ELECTRICAL SWITCHGEAR CABINET: COLOR TO MATCH GRAND BLANC ARCHITECTURAL MASONRY "S.E.D. BLEND" OP BURNISHED CMU WINGWALL TO HIDE THE SWITCHGEAR: COLOR TO MATCH GRAND BLANC ARCHITECTURAL MASONRY "S.E.D. BLEND" OQ STANDARD MECHANICAL EQUIPMENT NOTE: VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. REAR ELEVATION CORRUGATED METAL DECK - WELDED TO INSIDE OF GATE FRAME. PAINT TO MATCH RAL 7038/MATTE TIGER DRYLAC �� 12'-0" BLOCK CAP COLOR TO MATCH BURNISHED CMU 8" BURNISHED CMU WALL - INTEGRAL COLOR TO MATCH BLDG 1 1/2" x 1 1/2" x 3/16" STEEL TUBE GATE FRAME. FULLY WELD - PAINT. 6" x 6" x 6' TALL STEEL PIPE. FILL SOLID WITH CONCRETE. WELD HINGES TO FACE OF PIPE. 8" BURNISHED CMU WALL - INTEGRAL COLOR TO MATCH BLDG HEAVY DUTY CANE BOLT WITH SLEEVES IN CONC. SLAB - OPEN AND CLOSED POSITIONS. 6" CONC. SLAB WITH # 3'S 0 18" O.C. EACH WAY OVER AGG. BASE. SEE SITE PLAN FOR CONFIGURATION 1" DIA. SLEEVES FOR CAN BOLTS PAINTED 6'-0" HIGH GATES, STEEL DECK FASTENED TO INSIDE OF METAL FRAME. 6" DIA. PAINTED BOLLARDS 8" CMU WALL TO MATCH BUILDING MATERIALS AND COLORS. o VAC SOUTH ELEVATION VAC o1 / 21506 TRASH ENCLOSURE PLAN /ELEVATIONS DRAWN BY: CL DATE: 03/24/2022 SCALE: 1 8 = , -o 1. SCALE: 3/16" = V-0" Sheet No. a y TIRE CONCEPTUAL COLOR ELEVATIONS 1055eIndian school rd. • phoenix, az 85014 -;`1' 602.307.5399 1 v Cm,712 1636 S E M I N O LE TRAIL ARCHITECTURAL www.art-team.com RESOURCE CHARLOTTESVI LLE, VA 22901 TEAM X ------ I \, \ 996• I 1 III ` 496 I I 1 \ _ ,III l i d. III 494 \. a � (� \\ 493 ' ,/, ---'" 13+50 \ 7 -- i 510 500 490 I I I I I I I I - 1 I I , I ' I I I I I I I I ' I pg5- - - - - - - 11 1 //���\I��� �F \\�`/�{) __ _ I,11 I'll l�l, _ MQL TA4/L , ;RTE� 29�1\ -- - __ _ '111 II11 -- / r `\ ; I '1'II111'�_- - %II III III II II I111 p/ l,' 4 \/ r \ ---------_ I I I I "" • -- III 'I''I' �' ' I' AR/AU6E AD7N R/GH \O Y/A/ \ 1 1 I 1 I'I I I I i / ;1 ; I'I I i ;IIII '1 j'1 I �/�/1 b //� 1 ��/yam p� TU d \ , %, --- *r0'1P1✓BL/C )FOAOWAY - APPROXIMAM RO II. f/- 162 A' 1 o I 1 .. _ __ ___III I I I I IIII IIII / 111 IIII 1 I VO of ryj, 00 \ \[l I I'Illllll' % 11'I; '111'II ;I'I'II I'Ijl I YUOT RWECT UN29-V✓2-901 V' \ � I' I I I I I I I I I I I IIII 11 I I 11 111 I I' 11 1111 (PI )F,O SPEDNb 45 MPH) 1 I 1 — 1111 1 \ 11 I i i i i i I�T1 i �— 5"0 212.5 mmllll 111= 50' 0 T�OSIGHt DIStANCE LINE — — — PROP. �, — — — — — PROR GRADE / EX. GRADE i 10+00 10+50 11+00 11+50 12+00 12,50 13,00 13,50 14+00 14+60 15+00 STOPPING SIGHTDISTANCE SCALE: 1'= 50' HORIZONTAL V= V VERTICAL 510 500 490 W mi x O m z EE w w w 10 z F� w z W��w� 0Z UWrn jW zrCDt=ohm Fwa= wz H �OW02 r=n a Q z Q �002ow zaaa~O Q J 00 w Z z as > aJ of O w H U3 REVISIONS REV I DATE I COMMENT 1 110129120211 PER ISP COMMENTS I ' 2 I01/21/2022I PER COUNTY COMMENTS I RTY 3 04/08/2022 PER COUNTY COMMENTS BSC RTY 15 Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: PLOS-2 PROJECT: SITE PLAN DOCUMENTS FOR DIStUMU PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLERI 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@BohlerEng.com TH Lic. No. 0402056625 04/08/2022 SHEET TITLE: SIGHT DISTANCE PROFILE SHEET NUMBER: C-801 a a REVISION 3 - 04/08/2022 12' 2.0" ASPHALT SURFACE COURSE (Si EFLECTIVE ALUMINUM LEGEND AND BORDER - GREEN RESERVED WHITE SYMBOL ON BLUE BACKGROUND PARKING BACKGROUND -WHITE TYPICAL AT ALL ADA SPACES `-10.0" COMPACTED STONE BASE (VDOT 21A/B) VAN ACCESSIBLE THIS SIGN TYPICAL AT Al ACCESSIBLE" PARKING SPACES PENALTY SIGN WITH WORDING AS COMPACTED SUBGRADE REQUIRED BY STATE OR LOCAL LAW (PER GEOTECHNICAL REPORT) NOTE: 1. SECTION SHOWN IS BASED ON AN ANTICIPATED CBR OF 5 PER GEOTECHNICAL ALVANIZED "U" CHANNEL POST REPORT PREPARED BY ECS MID -ATLANTIC, LLC, ENTITLED DISCOUNT TIRE CHARLOTTESVILLE, DATED 05/25/21 (PROJECT #28:2549). FINAL DESIGN TO BE Zi PROVIDED ONCE FINAL CBR'S ARE AVAILABLE ON COMPACTED SUB -BASE. 0 U) 4" CIA. SCH. 40 GALVANIZED STEEL PIPE m O BOLLARD PAINTED OSHA YELLOW FILLED O � O =0 1 WITH CONCRETE m LU qI LIGHT DUTY ASPHALT PAVEMENT SECTION F I NOT TO SCALE o Wes, m ? PAINT CONCRETE BLACK AFTER ^O I CURING AT ASPHALT LOCATIONS J 1[ _ �4000 PSI CONCRETE 1�W 56, 111 5511�� yalticl`.-`.Iylticl`.-`.IyI• • • • • ° ° I � �Y�I_�Y_�7#2�I�G2$2Y�I�12122�Y_b�82Y�[2Y_�I \\\\\\\\\\\\\\\\\\\\\\\\00\ i1—��`1—��1- dip, �1—z�`lviii NOTE: ONE AT EACH ADA SPACE. WHERE ADA SPACES FACE EACH OTHER WITHOUT WALKWAY, THERE SHALL BE ONE POST WITH SIGNS MOUNTED BOTH SIDES OLLARD MOUNTED ADA PARKING SIGN CONCRETE FILL TO BE ROUNDED FOR PROPER RUN OFF 4" DIAMETER STEEL PIPE FILLED W/ CONCRETE PAINTED TRAFFIC YELLOW AND EMBEDDED IN CONCRETE BASE TOP OF ASPHALT OR CONCRETE SLAB 3000 P.S.I. NOTE: 1. SEE SITE PLAN FOR LOCATION(S). MIN. 0 v 0 m BOLLARD DETAIL NOT TO SCALE J F W N z 3 a w u, N z 3 a z z 3 0 U 3,000 P.S.I ASPHALT OR CONCRETE AS DETERMINED BY TRAFFIC SURFACE CONCRETE -TO -ASPHALT DETAIL NOT TO SCALE 2' MIN. CLEAR ZONE (TYP., LT. & RT.) VARIES 2% MAX. CROSS SLOPE COMPACTED SUBGRADE GEOTECHNICAL REF L­4" CLASS A CONCRETE (3000 P.S.I. @ 28 DAYS) 4" THICK, COMPACTED STONE BASE (TYPE 2a) NOTE: 1. EXPANSION JOINTS 1/2" WIDE PREMOLDED BIT. MATERIAL SHALL BE INSTALLED AT 30' INTERVALS, CRACK CONTROL JOINTS TO BE SPACED AT INTERVALS EQUAL TO SIDEWALK WIDTH. CONCRETE SIDEWALK DETAIL NOT TO SCALE TRUNCATED DOME 5'-0" MIN. NOTE: ADA ACCESSIBLE RAMP CONSTRUCTION SHALL CONFORM TO CURRENT ADA ACCESSIBLE GUIDELINES. ADA ACCESSIBLE RAMP DETAIL NOT TO SCALE 8" COMPACTED STONE BASE (VDOT 21A/B) COMPACTED SUBGRADE (PER GEOTECHNICAL REPORT) NOTE: 1. SECTION SHOWN IS BASED ON AN ANTICIPATED CBR OF 5 PER GEOTECHNICAL REPORT PREPARED BY ECS MID -ATLANTIC, LLC, ENTITLED DISCOUNT TIRE CHARLOTTESVILLE, DATED 05/25/21 (PROJECT #28:2549). FINAL DESIGN TO BE PROVIDED ONCE FINAL CBR'S ARE AVAILABLE ON COMPACTED SUB -BASE. CONCRETE SECTION NOT TO SCALE W mi O Im 0 Z EE W W W to Z F W W Z W H W (DzwW� jW Z 7-01 W I FWa= Wz >zUW1n0 U) 7 m a Q Z a z J) W ZFH °Of zof aaa~O z J 0 0 Z) W Z as > azJ of 0 W i U) REVISIONS REV DATE COMMENT DBAwx er CHECBED BY 1 10/29/2021 PER ISP COMMENTS DSH RTY 2 01/21/2022 PER COUNTY COMMENTS BSC RTY 3 04/08/2022 PER COUNTY COMMENTS BSC RTY Know what's belOW, Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: Cl PROJECT SITE PLAN DOCUMENTS FULL HEIGHT CURB CURB TAPER I 1" RADIUS FOR VARIES DISC®C�7aQ PAVEMENT CURB TAPER DETAIL NOT TO SCALE PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLER// 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA23146 Phone: (804)893-8200 VA@BohlerEng.com 6 JJJJJJJ 1JJJ m JJJJJJ JJJ. JJJ 114" RADIUS 2" RADIUS JJJ�S 1JJJ 18" SQUARE CONCRETE JJJJJJJJJJ ENCASEMENT FINISHED GRADE fjj JJJJJJ (3000 P.S.I CONCRETE) /,--6" REVEAL ��TH (�11 RATED CLEANOUT COVER FINISHED GRADE 2" ASPHALT OR CONCRETE r 4" SEWER CLEANOUT CAP — — _ ✓S"( 5 ',:::: •.; III —I (— SAND CUSHION — — Eli- 3000 P.S.I. CONCRETE 6" PVC ENCASEMENT PIPE TRAFFIC RATED CLEANOUT DETAIL NOT TO SCALE Q 'v NI�Trc+. 1. EXPANSION JOINTS TO BE INSTALLED AT 20' INTERVALS. 2. THIS ITEM MAY BE PRECAST OR CAST IN PLACE. 3. CONCRETE TO BE CLASS A3 IF CAST IN PLACE OR 4000 P.S.I. IF PRECAST. Lic. No. 0402056625 04/08/2022 SHEET TITLE: CONSTRUCTION DETAILS SHEET SHEET NUMBER: C-901 HEADER CURB DETAIL NOT TO SCALE REVISION 3 - 04/08/2022 m J W 91 U F O )­ Z U 0 N 2016 ROAD & BRIDGE STANDARDS GR-HDW 55• 5' IEUTR L IS 11F •• R W BEAM ss - ss• BACK - UP PLATE POST BOLT. AND NUT 4-'GE BOLT" WIi r-a PER JOINT LAP N DIRECTION OF TRAFFIC DETAIL OF SPLICE JOINT SECTION THRU RAIL ELEMENT AND W BEAM BACK-UP PLATE 3• %-- mCIREA rOA. z yX" DEEP. RECESS ONE OR H BO SIDES/ • I ELLIPTICAL, SLOTTED HOLE L• I:/" FOR SPACE DIY!-FLLL LENGTH THREADS DETAIL OF STANDARD WASHER L- 2" FOR SPLICE BOLT -FULL LENGTH THREADS OR NESTED W BEN6. L" 10" FOR STEEL POST BOLT-1%a' MN. THREADS L- 16" FOR WOOD AND CONCRETE POST BOLT-ZyE' MIN. THREADS L- 26" FOR MD WOOD OR CONCRETE POST-2" MN. THREADS NOTES: DETAIL OF BUTTON HEAD BOLT AND RECESS NUT ALLSPEHARDINMEHE Is TO BE GALVANIZED IN ACCORDANCE WITH THE (GUARDRAIL BOLT) THE GUARDRAIL AID MEDIAN BARRIER COMPONENTS DEPICTED IN ARTBA TECHNICAL BULLETIN NUMBER 2688 MAY BE SUBSTITUTED F NTERLHAN(£ABLE WITH THE STANDARDS FOR GU DRIL (M) OR MEDIAN GAM(MB E BE AND APPROVED BY THE ENGINEER. REFERENCElie STANDARD GUARDRAIL HARDWARE READ AND BRIDGE STADARDS 221 505 REVISION DATE BEET 1 OF 3 VIRGINIA DEPARTMENT OF TRANSPORTATION OV14 501A1 2016 ROAD & BRIDGE STANDARDS /DOT 2016 ROAD & BRIDGE STANDARDS GR-row NEUTRAL ME NOTE! 3" LAP N DIRECTION OF }y TRAFFIC AT SPLICE JOINT. --� - 2516 BE REO'D. 'I.AL INL4 FOR l5E N GR-]. "POST BOLT SLOT I B T SLOT qA " x f/" �RECI ILO NODE OILY -� T SL X POST GMT CONNECTOR T WARY PpO0ST T SLOT SLOT I ILA I�NC�7FOR 'ri' % 2�F/t' W BEAM TERMINAL CONNECTOR IN BEAM END SECTION (FLARED) O 01'1 m iIF TIE GUNNMAL IEDUN BARRER COPOIENTS 12 DEPICTED N AR.T.B.ATECINCAL BULLETIN NUMBER MM MAY BE SIRSn1lRFD IF N - I CHANGEABLE WITH THE STANDARDS FOR 3p�%%%222������ APPROVED (GRIOR MEDIAN BAePEV (IB)ND By ' APPROVED BY THE ENGINEER. O : o;L pd g sLOTTm NOIEs qa" X f/F" S ,-:V$ T SLOT ♦ STANDND DIMENSIONS OF 12'/2".24" AND W" ARE SUGGESTED. W BEAM END SECTION (BUFFER) W BEAM END SECTION (ROUNDED) ROAD ANDxv s,yo,,nDS STANDARD GUARDRAIL HARDWARE RENCE SMELT 2 OF 3 REVISION DATE W-BEAM GUARDRAIL HARDWARE 221 501.02 KRONA DEPARTMENT OF TRANSPORTATION 505 ACCESS MANAGEMENT EXCEPTION REQUEST: All ACCESS MANAGEMENT REGULATIONS 24 VAC 30-73 SECTION 120 February 2015 Submitted by: Ms. Holly Hatcher Date: B/2/2021 Email Address: hhatcher@bohlereng.com Phone: (804)893-8200 Address: 2150 Ashland Road, Suite 200, Richmond, VA 23146 Project Name: Discount Tire -Seminole Trail Rte8 US 29 IDcalily: Albemarle County Description of Project Discount Tire is proposing to replace the existing Wendy's resturant at 1636 Seminole Trail with a new Discount Tire store. The parcel has two right -in / right -out driveways on the US 29 southbound on ramp from Rio Road. The applicant is proposing to close the north driveway, and retain the south driveway. This AME request refers to spacing between the south driveway and the Commercial driveway that is 150 feet to the north. VDOT District: Culpeper Area Land Use Engineer: Adam Moore, P.E. NOTES: (1). submit this form and any attachments to one of the Dlstrices Area Land Use Engineers. (2). see Section 120 of the Regulations for details on the requirements, exceptions, and exception request review process. (3). Attach additional information as necessary to justify the exception requests). (4). If a traffic engineering study is required, the decision on the request will be based on VDOT engineering judgment. IS). Use the LD-Mw Design Exception or the LD-448 Design Waiver forms for design and engineering standards, e.g. radius, grade, sight distance. See IIM-LD-227 on VDOT web site for additional instructions. Select the Exceptions) Being Requested ❑ Exception to the shared commercial entrance requirement. (Access M. Regulations Section 120 C.2) Reason for exception: ❑ A. An agreement to share the entrance could not be reached with adjoining properly Owner. ❑ Attached: Written evidence that adjoining property owner will not share the entrance. ❑ B. Physical constraints: topography, adjacent hazardous land use, stream, wetland, other. ❑ Specify constraint: ❑ Attached: Documentation of constraint such as aerial photo or topographic map. ❑ Exception to the vehicular connection to adjoining undeveloped property requirement. (Section 120 CA) Reason for exception: ❑ A. Physical constraints: topography, adjacent hazardous land use, stream, wetland, other. ❑ Specify constraint: ❑ Attached: Documentation of constraint such as aerial photo or topographic map. B. Other reason: IV VDOT 1 ACCESS MANAGEMENT EXCEPTION REQUEST: AM-E ACCESS MANAGEMENT REGULATIONS 24 VAC 30-73 SECTION 120 February 2015 Submitted by: Ms. Holly Hatcher Date: g/Z/2oz1 Email Address: hhatcher@bohlereng.com Phone: (804)893-82DO Address: 2150 Ashland Road, Suite 200, Richmond, VA 23146 Project Name: Discount Tire -Seminole Trail RteIf US 29 locality: Albemarle County Description of Project: Discount Tire is proposing to replace the existing Wendy's resturant at 1636 Seminole Trail with a new Discount Tire store. The parcel has two right -in / right -out driveways on the US 29 southbound on ramp from Rio Road. The applicant is proposing to close the north driveway, and retain the south driveway. This AME request refers to spacing between the south driveway and the Speedway driveway that is 105 feet to the south. VDDT District: Culpeper Area Land Use Engineer: Adam Mcore, P.E. NOTES: (1). submit this form and any attachments to one of the Dlstrices Area Land Use Engineers. (2). see Section 120 of the Regulations for detach on the requirements, exceptions, and exception request review process. (3). Attach additional information as necessary to justify the exception request(s). (4). If a traffic engineering study is required, the decision on the request will be based on VDOT engineering judgment. (5). Use the LD-440 Design Exception or the LD-448 Design Waiver forms for design and engineering standards, e.g. radius, grade, sight distance. See IIM-LID227 on VDOT web she for additional instructions. Select the Exceptioni Being Requested ❑ Exception to the shared commercial entrance requirement. (Access M. Regulations Section 120 C.2) Reason for exception: ❑ A. An agreement to share the entrance Could not be reached with adjoining property owner. ❑ Attached: Written evidence that adjoining property owner will not share the entrance. ❑ B. Physical constraints: topography, adjacent hazardous land use, stream, wetland, other. ❑ Specify constraint: ❑ Attached: Documentation of constraint such as aerial photo or topographic map. ❑ Exception to the vehicular connection to adjoining undeveloped property requirement. (Section 120 CA) Reason for exception: ❑ A. Physical constraints: topography, adjacent hazardous land use, stream, wetland, other. ❑ Specify constraint: E] Attached: Documentation of constraint such as aerial photo or topographic map. ❑ B. Other reason: 2016 ROAD & BRIDGE STANDARDS 2016 ROAD & BRIDGE STANDARDS M-2.2A 27Y4' MIN - 28Y4" MAX RAIL HEIGHT g•.}•• 6'-}•• X-1y2" N-0/2" 3'-0/" 3'-1/t' x GR-2 GR-2A (6'-3" POST SPACING) (3'-N/" POST SPMJNGI MAX DYNAMIC OEPLECDOIN - S' �IMAX DYNAMIC DEFLECTDR - 2' NOTES: J�L GUMDR/ LOCATIONS SHOWN ON FLANS ME APPRO%IMATE OWY MO CM HEA DUSTED WRING CONSTRUCTION IF AND AS DIRECTED BY THE ENGINEER. z FOR DETAILS OF POST AND BLOCKOUTS SEE SHEET ND. 501.05. • OPTIMAL GR- A 2 METHOD OPTKNIL M 2A METHOD USING NESTED RNL USING N B BACK OF FOR CITALS OF RAIL ELEMENT, SHEET ADS. 50 JOINT, END RNL ON BMX a POST ASSOCIATED HA®WAE SEE SHEET NOS. SOt01 AND 5011.02. z WHEN NESTED RAIL POST PACING WI L B S PLACED ON BECK OF Posi BAT ELEMENTS ME DFURNISHED SHOP CURVED FOR RMr FOR GR-2A THE POST SPRING WILL BE 6'-3'. BETWEEN 5 FEET AND 150 FEET. AL 0.UfDBNL POSTS SHALL BE SET PLUMB. T SHALL NOT BE SET WITH A VACATION OF MORE THAN ' a" PER FODT FROM VERTICAL. W-BEAM. BLOCKOUTS. AND POSTS SMALL BE SET AND ACTED WITHOUT ALTERATION OR FORCE.AS PER SECTION Soo OF THE SPECIFICATIONS. AL OR-2 AND CR-2A RNL HALL BE MAINTAINED AT A HE MT OF 27g" ARM - 28 i' MAX AS MEASURED PER STANDARD OR AL W-BEAM RNLS SHALL BE LAPPED N THE DIRECTION OF VEHICULAR TRAVEL FOR THE FINISHED ROADWAY. THE OPTIONAL M-2A METHODS OF NESTING THE RAIL OR USE OF AN ADDITIONAL RAE ON THE BACK OF THE POST FOR STANDARD CR-2A SHALL BE APPROVED BY THE ENGINEER PRIOR TO NSTALATION. FLARE RATES DESIGN SPEED INSIDE SHY LINE BEYOND SHY LINE MPH SHY LIRE L5 FLNE A* RATE FLARE RATE 70 9' xi:f eil • 60 B' 28:1 14:1 t 50 2k1 R1 • 40 5' D:1 B:1 t 30 9' 1.. 70 • R..I ICU MN{IMUM HLA RAIL FOR SLMI-RCIO BARRER SYSTEMS. ROAD AND BSarS STANDARDS ALOFT OF TIE ORIGINAL SEALED AND SCNED ORAWNG Is ON FILE N THE CENTRAL OFFICE. SPEOFIGTDN STANDARD BLOCKED -OUT W-BEAM GUARDRAIL REFERENCE BEET 1 OF 2 REVISION DATE (STRONG POST SYSTEM) slie 501.04 08/14 VIRGINIA DEPARTMENT OF TRANSPoRTATNN February 2015 ❑ Exception to the Commercial entrance shall not be located within the functional area of an intersection requirement. (See Regulation Section 120 C. 1: Appendix F, Rd Design Manual) ❑ Attached: Atraffic engineering study documenting that the operation of the intersection and public safety will not be adversely impacted. ❑✓ EXCEPTION TO THE SPACING STANDARDS FOR: • Commercial entrances; intersections/median crossovers (Table 2-2); • Commercial entrances/intersections near Interchange ramps (Tables 2-3, 2-4); or a Corner clearance (Figure 4-4). Appendix F, Road Design Manual Information on the Exception Request © ON A STATE HIGHWAY Functional classification: Principal Arterial: ® Minor Arterial: ❑ Collector: ❑ Local: ❑ Posted speed limit: 45 mph ❑ NEAR AN INTERCHANGE RAMP (Submittal of a traffic engineering study required) ❑ CORNER CLEARANCE (Submittal of a traffic engineering study required) Type of intersection/entrance: Signalized ❑ Unsignalized © Full Access ❑ Partial Access Required spacing distance 305 It Proposed spacing distance 150 It Requested exception: Reduction in required spacing 155 ft REASON FOR EXCEPTION: ✓❑ A. To be located on an older, established business Corridor along a highway where existing spacing did not meet the standards prior to 7/1/08 or 10/14/09. (Regulation Section 120 C.3.c) ❑✓ Attached: Dated aerial photo of corridor identifying proposed entrance/intersection location. ❑ B. Not enough property frontage to meet spacing standard, but the applicant does not want a partial access right-in/right-out entrance. (Section 120 C.3.0 ❑ Attached: A traffic engineering study documenting that left turn movements at the entrance will not have a negative impact on highway operation or safety. ❑ C. To be located within a new urbanism mixed use type development. (Section 120 C.3.d) ❑ Attached: The design of the development and compliance with intersection sight distance. ❑ D. The proposed entrance meets the signal warrants but does not meet the signalized intersection spacing standard. The applicant requests an exception to the spacing standard. ❑ Attached: A traffic engineering study that (1) evaluates the location's suitability for a roundabout and (ill provides documentation that the proposed signal will not impact safety and traffic Flow. (Section 120 C5) 2 February 2015 Exception to the commercial entrance shall not be located within the functional area of an intersection requirement. (See Regulation Section 120 C 1: Appendix F, Rd Design Manual) ❑ Attached: Atratfic engineering study documenting that the operation of the intersection and public safety will not be adversely impacted. ❑ EXCEPTION TO THE SPACING STANDARDS FOR: • Commercial entrances; intersections/medlan crossovers (Table 2-2); is Commercial entrances/intersections near interchange ramps (Tables 2-3, 2-4); or • Corner clearance (Figure 4-4). Appendix F, Road Design Manual Information on the Exception Request ® ON A STATE HIGHWAY Functional classification: Principal Arterial® Minor Arterial: ❑ Collector: ❑ Local: ❑ Posted speed limit: 45 mph ❑ NEAR AN INTERCHANGE RAMP (Submittal of a traffic engineering study required) ❑ CORNER CLEARANCE (Submittal of a traffic engineering study required) Type of intersection/entrance: Signalized ❑ Unsignalized © Full Access ❑ Partial Access Required spacing distance 305 it Proposed spacing distance 105 It Requested exception: Reduction in required spacing 200 ft REASON FOR EXCEPTION: ✓❑ A. To be located on an older, established business Corridor along a highway where existing spacing did not meet the standards prior to 7/1/08 or 10/14/09. (Regulation Section 120 C.3.c) ❑✓ Attached: Dated aerial photo of corridor identifying proposed entrance/intersection location. ❑ B. Not enough property frontage to meet spacing standard, but the applicant does not want a partial access right-in/right-aut entrance. (section 120 C.3.0 ❑Attached: Atraffic engineering study documenting that left turn movements at the entrance will not have negative impact on highway operation or safety. ❑ C. To be located within a new urbanism mixed use type development. (Section 120 C.3.d) ❑ Attached: The design of the development and Compliance with intersection sight distance. ❑ D. The proposed entrance meets the signal warrants but does not meet the signalized intersection spacing standard. The applicant requests an exception to the spacing standard. ❑ Attached: A traffic engineering study that (1) evaluates the location's suitability for a roundabout and (ii) provides documentationthat the proposed signal will nut impact safety and traffic Flow. (Section 120 CS) 2016 ROAD & BRIDGE STANDARDS February 2015 ❑, E. The development's 2"d (or additional) entrance does not meet the spacing standards but is necessary for the streets to be accepted into the secondary system. (Section 120 C.3.e) ❑. Attached: Information on the development that identifies the location of entrances. ❑ F. To be located within the limits of a VDOT and locality approved access management Corridor plan. ❑ Attached: Aerial photo of corridor identifying proposed entrancefintersection location. (Sect 120 C.3.b) FOR VDOT USE ONL Recommendation on Exception Request: Approwl DI I I Date: 8/6/21 Area Land Use Engineer or: Name Adam 1. Moore, PE Remarks: The Residency recommends approval Contingent upon an approved she plan for the new entrance based on the following factors: 1. The local lanes of Route 29 at Route 631 were constructed in part to serve the businesses near the intersection. This parcel is one such site. 2. The existing topography to the north and south prevent a practicable shared entrance or even a feasible inter -parcel connection. 3. The proposed right in right out entrance does not introduce any new conflict points from the existing pair of one-way entrances. 4. The proposed use is a less intense traffic generator than the fast food restaurant previously located at this site Verbal concurrence given by Carrie Shepheard, PE on 8/3/21 Exception Request Action: Approved✓ Denied I Date: District Administrator or Designee: Michelle A Shmpahim 2021 nR 2e 1327la Q4 VT Name (and position if Designee) Remarks: Stamped concrete (brick pattern) "walkway" area across entrances to be maintained or replaced. District Staff: Please email copy to Bradlev.Shefton@VOOT.Viminia.00v 3 February 2015 ❑ E. The development's 2n0 (or additional) entrance does not meet the spacing standards but is necessary for the streets to be accepted into the secondary system. (section 120 C.3.e) ❑ Attached: Information on the development that identifies the location of entrances. ❑ F. To be located within the limits of a VDOT and locality approved access management Corridor plan. ❑ Attached: Aerial photo of corridor identifying proposed entranceAntersection location. (Sect 120 C.3.b) FOR VDOT USE ONL Recommendation on Exception Request: Approve✓ Denyl I I Date: 8/6/21 Area Land Use Engineer or: Name Adam). Moore, PE Remarks: The Residency recommends approval contingent upon an approved site plan for the new entrance based on the following factors: 1. The local lanes of Route 29 at Route 631 were constructed in part to serve the businesses near the intersection. This parcel is one such site. 2. The existing topography to the north and south prevent a practicable shared entrance or even a feasible inter -parcel connection. 3. The proposed right in right out entrance does not introduce any new conflict points from the existing pair of one-way entrances. 4. The proposed use is a less intense traffic generator than the fast food restaurant previously located at this site. Verbal concurrence given by Carrie Shepheard, PE on 8/3/21 Exception Request Action: Approved(✓ DenieI Date: District Administrator or Designee: Name (and position if Designee) Remarks: Stamped concrete (brick patent) "walkway" area across existing entrances to be maintained or replaced. District Staff: Please email copy to Bradlev.SheltonCalVDOT.Viroinia.Oov W-12 A 45 DOWELS. 6" LORC�WT AT II C-C 5'YN. PERYSSIBL£ TRUCTION 2:1 SAX IT I I Z tt:t MAk � B 1 J r-, -IHA H. caulI A TO 20.1 TH9 0 T. "M GUTTER PAN SLOPE TO 20-1 THROUGH RNAP LENGTH CUTTER PIN 4AXY.4 SLOPE 20H 5'-0" MIN SHAPE TO MATCH FALL CE ROADWAY O.IRB BACK OF CURB 20:1 4 : i` Tq rla, UR�in Pl �'=ate •I .• r� PNdHG 99:1 M0%. 2'YN. SECTION A -A `aE"R e14A `slorc DETECTABLE WARNING SURFACE PERMISSIBLE DUN. CONSTRUCTION sMw JOINT CROSSWALK �$n $_ i J SECTION B-B Cos aRR CONCRETE NOTES: ONE DRECTiON 1. FOR GENERA. NOTES ON THE DETECTABLE WARNING SURFACE. WITHOUT BUFFER STRIP SEE SHEET IOF 5. 2. THE REQUIRED LENGTH OF A PARALLEL RAMP N LIMITED TO 15 FEET, REGARDLESS OF THE SLOPE. 3. GUTTER PM SHALL BE A MAXIMUM SLOPE OF 20+1 AT THE RAMP OPENING. 4. DIAGONAL PLACEMENT IS NOT PERMITTED. TYPE B PARALLEL APPLICATION ROADWAY GRADE IN PERCENT MNIWM RAMP LENGTH IN FEET 4" CURB 6" CUR 0 4 6 1 5 7 2 5 a 3 6 9 4 12 5 D 15 6 14 15 ROAD AND BRIDGE STANDARDS SHEET 3 or 5 REVISION DATE 204.03 04/11 Wil CROSSWALK CROSS ' L nn II 11 CROSSWALK TWO DIRECTIONS SMALLER RADII WITHOUT BUFFER STRIP A COPY OF THE ORIKNAL SEALED AND SIGNED DRAWING 5 ON FILE N THE CENTRAL OFFICE. CC-12 DETECTABLE WARNING SURFACE TYPE B (PARALLEL) APPLICATION VIRGINIA DEPARTMENT OF TRANSPORTATION 2016 ROAD & BRIDGE STANDARDS ONE DIRECTION WITH BUFFER STRIP 2016 ROAD & BRIDGE STANDARDS TACK COAT THE PROPOSED CONSTRUCTION JOINTEXISTING MmALT LAYERS PROPOSED ASPHALT LAYERS - EXSTING SUBBASE PROPOSED SUBBASE ----------------- c-M--- IsLNGRNE CONSTRUCTION JOINT DETAIL ® REMOVE EXISTING ASPHALT LAYERS TO EXISTING SUBBASE AD REPLACE WITH PROPOSED ASPHALT WIDENING LAYERS ® PROPOSED MINIMUM I / NCH THICK ASPHALT SURFACE COARSE )SEE NOTE 5) A MINIMUM 12 ACHES, OR GREATER AS NECESSARY TO ABUT THE FULL THICKNESS OF EXISTING ASPHALT LAYERS AS DETERMINED BY CORES (SEE NOTE 3) Ds SPECIFICATION REFERENCE He 502 504 NOTES: 1. ASPHALT PAVEMENT WIDENING SHALL HAVE A PAVEMENT DESIGN N ACCORDANCE WITH CURRENT VUOT PROCEOURES AND BE APPROVED BY THE ENGINEER. 2. THE PAVEMENT DESIGN FOR ASPI49LT PAVEMENT WIDENING SHALL MEET OR EXCEED THE DEPTHS AND TYPES OF THE LAYERS OF EXISTING PAVEMENT. SUBSURFACE DRAINAGE OF THE EXISTING AND PROPOSED PAVEMENT SHALE BE MORESSEO N THE PAVEMENT DESIGN. 3. A MINIMUM OF THREE CORES SHNL BE TAKEN ALONG THE CENTER OF THE ADJACENT TRAVEL LANE TO DETERMINE THE TYPE AND THICKNESS OF EXISTING PAVEMENT LAYERS. THESE CORES SHALL BE SPACED NO MGM THAN 50D FEET APART. 4. THE ADJACENT TRAVEL LANE SMALL HE MILLED A MINIMUM DEPTH OF 11/2 ACHES AND REPLACED WITH AN ASPHALT SURFACE COURSE TO MATCH THE PROPOSED PAVEMENT WIDENING SURFACE COURSE, UNLESS WAVED BY THE ENGINEER. 5. THE ENGINEER MAY REQUIRE THE MLLING DEPTH OF THE EXISTING PAVEMENT TO SE ADJUSTED TO ACHIEVE AN ACCEPTABLE PAVEMENT CROSS -SLOPE AND EFFECTIVE SURFACE DRAINAGE. 6. EXISTING PAVEMENT MARKINGS AND MARKERS WITHIN THE PROJECT LN6TS SHALL BE RESTORED SUBJECT TO THE APPROVAL DF THE ENGINEER . 7. FINAL TRANSVERSE PAVEMENT TIE-IN SHALL CONFORM TO THE REQUIREMENTS OF SECTION 315 OF THE SPECITCATIONS EXCEPT THAT ALL JOINTS AT IIE-IN LOCATIONS SHALL SE TESTED USING A D FOOT STRAIGHTEDGE IN ACCODMCE WITH THE REQUIREMENTS OF SECTION 315 OF THE SPECIFICATIONS. ROAD Aw ��STANDARDS ASPHALT PAVEMENT WIDENING FOR WIDENING SUBJECT TO TRAFFIC VIRGINIA DEPARTMENT OF TRANSPORTATION CATION REFERENCE 3t5 -SHEET + OF + REVISION DATE 30y 02 2016 ROAD & BRIDGE STANDARDS Z EE OJ 111 W (% Z F W 111 Z W H W 0 Z W W j W Z��� FLU< wZ >ZULU(n0 (� Z) 2 Q Q Z Q z(n�wZF� 0Zaaa~o Z J 00 Z) W Z z o Q o Q of J F U W H REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 1 10/29/2021 PER ISP COMMENTS Di RTY 2 01/21/2022 PER COUNTY COMMENTS BSC RTY 3 04/08/2022 PER COUNTY COMMENTS BSC RTY • Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: V211201 DRAWN BY: DSH CHECKED BY: RTY DATE: 10/29/2021 CAD I.D.: CNDS-2 PROJECT SITE PLAN DOCUMENTS FOR DISICUMQ PROPOSED LOCATION 1636 SEMINOLE TRAIL ALBERMARLE COUNTY CHARLOTTESVILLE, VIRGINIA 22901 BOHLER// I 2150 ASHLAND RD. SUITE 200 RICHMOND, VIRGINIA 23146 Phone: (804)893-8200 VA@BohlerEng.com rF_ALTH eI Lic. No. 0402056625 V� 04/08/2022 SHEET TITLE: CONSTRUCTION I DETAILS SHEET SHEET NUMBER: C-902 1 2 3 ALL DETAILS IN THIS BOX ARE PROVIDED BY OTHERS AND ARE FOR INFORMATIONAL PURPOSES, ONLY. BOHLER ENGINEERING SHALL BE HELD HARMLESS IN THE EVENT OF ERRONEOUS INFORMATION CONTAINED WITHIN THESE DETAILS AND/OR STRUCTURAL FAILURE. REVISION 3 - 04/08/2022