HomeMy WebLinkAboutSDP202200016 Review Comments Initial Site Plan 2022-05-11Ben Holt
Senior Planner, Planning
County of Albemarle bholt(rDalbemarle.org
_ Community Development Department Telephone: (434) 296-5832 ext. 3443
Memorandum
To: Justin Shimp, iustin(ashimo-eneineerine.com
Date: May 11, 2022
Re: SDP202200016 South Pantops — Parcel 20R — Initial Site Plan — Review Comments
All comments in the attached letter must be addressed prior to Final Site Plan approval: [Each comment is preceded by
the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified].
Albemarle County Planning Services (Planner) — Ben Holt, bholt(cbalbemarle.org
1. [32.5.2.A] — General info. Edit zoning note to read "Steep Slopes Overlay". GIS indicates only preserved slopes;
no managed slopes are shown on property.
2. [32.5.2.B] — Proposed use. Edit note to indicate thirteen (13) multifamily units. The note currently indicates 12
units.
3. [4.12.16.C] — Each parking space requires 10' x 18' dimensions. Indicate dimensions on each parking pad
adjacent to buildings and the overflow parking area.
4. [32.5.2.0] — Dedication. See attached deed book (book 2913, pages 156-162, note 6 on plat) regarding required
greenway dedication adjacent to the Rivanna River.
Please contact Ben Holt in the Planning Division by using bholt(cbalbemarle.orq or 434-296-5832 ext. 3443.
Comments from Other Reviewers:
Albemarle County Engineering Division — John Anderson, landerson2oalbemarle.org — requested changes, see
attached.
Albemarle County E911 Services — Andy Slack, aslackoalbemarle.org — requested changes, comments attached.
Albemarle County Building Inspections — Betty Slough, bsloughoalbemarle.org — requested changes, see attached.
Albemarle County Department of Fire & Rescue — Howard Lagomarsino, hlagomarsinooalbemarle.org — requested
changes, see attached.
Virginia Department of Transportation (VDOT) — Max Greene, max.greeneCDvdot.virginia.gov - requested changes,
see attached.
Albemarle County Service Authority (ACSA) — Richard Nelson, rnelson(&serviceauthority.org requested changes, see
attached.
Rivanna Water & Sewer Authority (RWSA) — Dyon Vega, dvega(&-rivanna.org — no objection.
Dept. of Conservation & Recreation (DCR) — Justin Deel, lustin.deel(&dcr.virginia.gov — no objection.
Albemarle County Parks & Recreation — Tim Paladino, tpadalinooalbemarle.org — comments pending.
WWW.ALBEMARLE.ORG
401 McIntire Road, North Wing, I Charlottesville, VA 22902-4579
qoH nt 401 McIntire Road, North Wing
Charlottesville, VA 22902-4579
County of Albemarle
o � � Telephone:434-296-5832
COMMUNITY DEVELOPMENT DEPARTMENT WWW.ALBEMARLE.ORG
�tBGIN��'
Site Plan review
Project title:
South Pantops Drive — Parcel 20R
Project file number:
SDP202200016
Plan prepares
Shimp Engineering, 912 E. High St., Charlottesville, VA 22902
iustin(a,shimp-engineering. com
Owner or rep.:
South Pantops H Land Trust; Charles W. Hurt & Shirley Fisher Trust
P.O. Box 8147, Charlottesville, VA 22906
Plan received date:
21 Mar 2022
Date of comments:
19 Apr 2022
Plan Coordinator:
Ben Holt
Reviewer:
John Anderson
Engineering has reviewed the initial site plan and offers these review comments for Final Site Plan approval.
SDP2022-00016
1. C2: Show linework for TMP parcel 07800-00-00-015C9 to immediate south of development parcel, 07800-
00-00-020R0. Label TMP 78-15C9; include ownership / deed bk.-pg. reference.
2. Note: If final site plan (FSP) encroaches on preserved steep slopes, revise to avoid proposed improvements
on preserved steep slopes.
a. SWM facility access may not traverse preserved steep slopes since, by definition, steep slopes
>25% will sustain more than minimal impact with an access less than 20% grade. Access,
required by ACDSM to be flatter than 20%, requires cross -contour grading of steep slopes, this
increases impact. ISP design showing SWMArea between preserved steep slopes is not an
approvable design unless approvable SWM facility access is provided. Also, item 2.e., below.
b. SWM facilities are not public facilities. Storm pipe is deemed permissible across preserved steep
slopes but only ifno other alignment that avoids steep slopes is possible. Any improvement,
including storm pipe, across preserved steep slopes must meet standards listed at 18-30.7.5, and
minimize impact to maximum extent possible.
c. Although ISP shows SWM facility outfall to an existing 15' drainage easement, both FSP and
WPO must provide considerable detail concerning receiving stream at point proposed new 15"
HDPE (SWM facility outfall) pipe intersects Ex. 15' drainage easement. Type, slope, condition,
stability of conveyance within existing easement, velocity; erosion: All are considerations. Also:
adequacy of channel between development and Rivanna River, which requires evaluation.
Existing conveyance may require improvement, improvement to be shown on FSP and WPO plan.
d. Please ref. process outlined at 18-30.7.4.b.l.h. (field run survey /county Engineer approval) and
18-30.7.6 (field run survey /county board approval) which alter or amend district boundaries.
Areas removed from steep slopes, whether by board or county Engineer approval, require field run
survey and LS/PE-sealed slopes exhibit. If removed, former steep slopes areas are eligible for
development as permitted in underlying zoning districts.
e. Note: If entrance to development receives runoff from S. Pantops Drive and conveys this off -site
runoff to on -site SWM, then that pipe network is public (between S. Pantops and on -site SWM)
and, provided no alternative exists, a proposed public drainage easement across preserved steep
slopes from S. Pantops Drive to proposed future SWM facility (which may not be located on
preserved steep slopes), may be permissible. This easement alignment might meet twin objectives
of storm pipe <_16% Max. grade and SWM facility access 10' Min. width, 20% max. grade, per
ACDSM [p. 11: Best Management Practicesfor SWMand drainage plan checklist for reviewers].
Engineering Review Comments
Page 2 of 3
3. Provide deed bk.-pg. reference for Ex. 15' drainage easement.
4. With ESP /WPO plan, provide VDOT LD-204, Stormwater Inlet Computation, and LD-229 Storm Drain
Design Computation (tables).
5. An approved WPO plan is required prior to ESP approval.
6. A recorded SWM facility /public drainage easement plat (with deeds) is required prior to WPO plan
approval. Easement plat application is a separate process, with on-line digital format application found
here. If development is to be subdivided into individual lots, easement (SWM /public drainage) may occur
with final subdivision plat.
7. Revise retaining wall design, slightly, to provide measurable clearance between Lot 7 and preserved steep
slopes. Recommend 5' minimum offset to allow retaining wall construction without preserved steep slopes
impact. Schematic representation showing one touching the other is not an approvable design, nor is such
design practically constructible without impact to preserved steep slopes.
8. Include Note to Contractor on WPO plan and ESP that all preserved steep slopes are to be flagged prior to
land -clearing, that clearing limits avoid steep slopes, and that flagging (delineating preserved steep slopes)
be maintained for the duration of construction /site development.
9. If development is subdivided, which appears possible, provide private sanitary easement across Lot 12 for
benefit of Lot 13.
10. Show and label existing ACSA sanitary sewer easement across development parcel.
11. Show and label proposed ACSA sanitary and water easements across development parcel.
12. Show /label private sanitary lateral easements.
13. If site is subdivided, provide and label site access easement.
14. Please note that SWM facility, public drainage, private drainage, SWM access, and ACSA easements
should be located outside lots, to extent practical, to avoid access /maintenance issues /dispute with owners.
15. Revise design to provide Lot 1 with sufficient space for vehicle to exit car parking, without hitting an
obstruction or leaving paved surface.
16. Provide CG-6 wherever design concentrates storm runoff against curbing.
17. Ensure site entrance provides vertical transition that meets VDOT commercial entrance vertical transition
standard (street grade less than 4% for a min. of 40' from the edge of pavement of the intersected street.
(This grade can be within the first road curve which transitions from the 2% intersected cross grade)
{policy, follows ord. for travelways 18-4.12) ).
18. ESP /WPO plan should provide positive grade and spot elevations to ensure that surface runoff does not
reach dwelling unit walls. USBC requires positive slope for a min. distance, measured from exterior walls,
but FSP/WPO must clarify design, and ensure positive drainage awayfrom front of units facing S. Pantops
Drive. Please provide contours that indicate positive drainage away from street -face of structures. Provide
yard inlets to convey surface runoff to SWM detention and treatment system.
19. Show /label ACSA water service to development, and laterals to each unit. Do not locate water meters
between paved 2-car parking at rear of attached units, as they are inevitably damaged at routinely trafficked
locations. Experience guides: water meter location between paved 2-car parking is disapproved.
20. Engineering recommends coordinate and submit steep slopes exhibit, if amendment to steep slopes district
boundary is proposed,
21. Please submit WPO application /plan at earliest convenience.
22. C3: Label heavy dash linework. If heavy dash line indicates limits of disturbance, exclude preserved steep
slopes from LOD, unless expressly permitted by ordinance.
Please feel free to call if any questions: 434.296-5832 -x3069
Thank you
J. Anderson
Engineering Review Comments
Page 3 of 3
SDP202200016_S_Pantops Drive parcel 20R_ISP 041922.docx
�y pF AL8
County of Albemarle
GEOGRAPHIC DATA SERVICES OFFICE
COMMUNITY DEVELOPMENT DEPARTMENT
PLAN REVIEW COMMENTS - E911
APPLICATION#: SDP202200016
TMP: 07800-00-00-02000
DATE: 4/8/22
Andrew Slack
aslack@albemarle.org
tel: 434-296-5832 ext. 3384
fax: 434-972-4126
We recommend providing three (3) candidate names for each road to our office for
review, in case your first choices are not acceptable.
Before final plans are submitted, please add a road name to the plans for the new travel way to
access the proposed structures.
A PDF version of the Ordinance and Manual can be found here:
https://gisweb.albemarle.org/Risdata/Road Naming and Property Numberin¢ Ordinance and Manual.odf
Please consult the County's Road Name Index to check your road names prior to submittal. The
Index can be found here: https://Ifweb.albemarle.org/Forms/RoadName]ndex
Parcel and mapping information can be found here: https://gisweb.albemarle.org/gpv 51/Viewer.aspx
If you should have any questions, please do not hesitate to contact our office.
WWW.ALBEMARLE.ORG
401 McIntire Road, Suite 228 1 Charlottesville, VA 22902-4596
SDP2022-16 S Pantops, Parcel 20R— Initial Site Plan
Comments: CDD Inspections— Betty Slough
bslouah@albemarle.ore
04-11-2022
Add the following to the general notes page:
• All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks.
Note to developer:
• Due to required distances from lot lines and structures as required by the NFPA, underground
propane tanks may be prohibited. Plan accordingly.
Replace note #12 under the General Notes with:
• All water, sewer and fire lines require NEW inspection and testing procedures. The ACSA
performs any testing and inspections of the public sewer and water main(s).
• The Albemarle County Building Inspections Department(ACBID) does a visual inspection and
witnesses the testing of the building drain, water service pipe and the sprinkler lead-in
connection.
• The developer/contractor is responsible to retain a Special Inspector as outlined in the updated
Albemarle County Policy for Site Utilities to perform the visual inspection and testing of all
utilities not covered by the ACSA or ACBID. This includes building sewers, water and fire line
branches between the main and the meter(s)/building(s).
• The Special Inspector's report must be submitted and approved by the Albemarle County
Engineering Department prior to a Certificate of Occupancy being issued.
SDP2022-16 S Pantops, Parcel 20R— Initial Site Plan
Albemarle Co Fire & Rescue — Howard Lagomarsino
hlaeomarsino@albemarle.org
04-14-2022
1) Please place a note on the plans indicating the needed fire flow for the buildings
2) The needed fire flow determines the hydrant spacing and distance of hydrants from the buildings. The
least strigent requirement is 500 ft. hydrant spacing and arranged so no building is more than 250 feet
from a hydrant. There are no hydrants indicated on the plan that even meet this requirement. Please
provide a hydrant to meet the requirements as specified by the needed fire flow.
3) The available fire flow must be sufficient to meet the needed fire flow. Place a note on the plan that
indicates the available fire flow.
4) Based on the width of the rear road, there will need to be no parking signs along both sides of the
road, except where the visitor parking spaces are indicated. Please note them on the plan.
5) During construction, the following fire prevention steps are required, so please note them on the
plan:
a) Smoking shall be prohibited in areas where smoking makes conditions such as to make smoking a
hazard and these areas shall be designated with no smoking signs per Virginia Statewide Fire Prevention
Code.
b) Areas where smoking can occur, shall have appropriate receptacles for discarded smoking
materials per Virginia Statewide Fire Prevention Code.
c) Per the Virginia Statewide Fire Prevention Code, vehicular access for firefighting shall be provided
at all construction and demolition sites, provide access to within 100 ft. of temporary or permanent fire
department connections, and have no overhead wiring or other overhead obstructions lower than 13 ft.
6 inches; this access may be via permanent or temporary road, but shall be capable of supporting fire
apparatus in all weather conditions.
d) Contractor shall ensure the street numbers are always plainly visible from the frontage street
during construction per the Virginia Statewide Fire Code
e) An approved water supply for firefighting operations shall be in place and available as soon as
combustible materials arrive on site.
f) Waste and combustible debris shall be removed from the building at the end of each day and
disposed of in accordance with the Virginia Statewide Fire Code
g) Fire extinguishers shall be provided, with not less than one approved fire extinguisher at each
stairwell, on all floor levels where combustible materials have accumulated, in every storage and
construction shed and in areas of special; hazards, such as where flammable and combustible liquids are
stored or used, in accordance with the Virginia Statewide Fire Code
h) Operations involving the use of cutting and welding shall comply with the Virginia Statewide Fire
Prevention Code and shall require a permit from the Albemarle County Fire Marshal's Office
(Z)
COMMONWEALTH of VIRGINIA
DEPARTMENT OF TRANSPORTATION
Stephen C. Brich, P.E. 1401 East Broad Street (804) 786-2701
Commissioner Richmond, Virginia 23219 Fax: (804) 786,2940
April 4, 2022
County of Albemarle
Department of Community Development
401 McIntire Road
Charlottesville, VA 22902
Attn: Ben Holt
Re: SDP-2022-00016 — South Pantops Drive -Parcel 20R
Review # 1
Dear Mr. Holt:
The Department of Transportation, Charlottesville Residency Transportation and Land Use
Section has reviewed the South Pantops Drive -Parcel 20R, dated March 11, 2022 as submitted
by Shimp Engineering, and find the following:
1. Existing site conditions page C2 should show the existing CG-12's and sidewalk along
adjacent properties.
2. Please show the entire length of proposed work within the R/W.
3. Please provide a comment response letter with each submission after the initial.
4. Note that the final plan must show conformance with the VDOT Road Design Manual
Appendices B(1) and F, as well as any other applicable standards, regulations or other
requirements.
A VDOT Land Use Permit will be required prior to any work within the right-of-way. The
owner/developer must contact the VDOT Charlottesville Residency Land Use Section at (434)
422-9399 for information pertaining to this process.
If you have further questions, please contact Max Greene at 434-422-9894.
Sincerely,
John C. Wilson, P.E.
Assistant Resident Engineer
Area Land Use
VDOT - Charlottesville Residency
VirginiaDOT.org
WE KEEP VIRGINIA MOVING
From: Richard Nelson
TO: Ben Hol
Subject: SDP202200016 South Pantops Drive — Parcel 20R— Initial Site Plan
Date: Friday, May 6, 2022 11:36:56 AM
CAUTION: This message originated outside the County of Albemarle email system. DO
NOT CLICK on links or open attachments unless you are sure the content is safe.
Ben,
I recommend SDP202200016 South Pantops Drive— Parcel 2011— Initial Site Plan for approval with
the following conditions:
Submit utility plan directly to ACSA for review.
Show existing water main and fire hydrant along South Pantops.
Show proposed water meter locations.
Provide detail for SWM utilities in relation to the existing ACSA 21-inch AC sewer.
Thanks,
Richard Nelson
Civil Engineer
Albemarle County Service Authority
168 Spotnap Road
Charlottesville, Virginia 22911
(434) 977-4511
From: Dvon Veaa
To: Ben H21S
Cc: devreviewCalrivanna.ora; Richard Nelson
Subject: South Pantops Drive RWSA Review.
Date: Thursday, April 7, 2022 11:35:38 AM
Attachments: 4maae001.ona
CAUTION: This message originated outside the County of Albemarle email system. DO
NOT CLICK on links or open attachments unless you are sure the content is safe.
Ben,
RWSA has reviewed the South Pantops Drive Initial site plan date 3/11/2022 by Shimp Engineering
and has no comments.
Thank you,
Dyon Vega
Civil Engineer
LANNEIIAUTHORITT
Rivanna Water & Sewer Authority
(434) 977-2970, Ext. 170
695 Moores Creek Lane
Charlottesville, VA 22902
www.rivanna.org
Please use our DevReviewt7a Rivanna.org email for all development review related Items, Thank