HomeMy WebLinkAboutWPO202100069 Review Comments WPO VSMP 2022-05-20t� OF ALB County of Albemarle COMMUNITY DEVELOPMENT DEPARTMENT ��BGIN�Q' Project title: Project: Plan preparer: Owner /Applicant: Applicant: Plan received date: (Rev. 1) Date of comments: (Rev. 1) Reviewer: VSMP Permit Plan Review Scottsville Tiger Fuel Market WPO2021-00069 401 McIntire Road, North Wing Charlottesville, VA 22902-4579 Telephone: 434-296-5832 WWW.ALBEMARLE.ORG Shimp Engineering, 912 E. High St., Charlottesville, VA 22902 Chris Marshall, PE — chris e shimp-en ing eerieg com James River Road LLC, 200 Carlton Road, Charlottesville, VA 22902 Gordon Sutton, 200 Carlton Road, Charlottesville, VA 2290 [ suttong&a tigerfuel com ] 7 Dec 2021 14 Apr 2022 6 Jan 2022 20 May 2022 John Anderson, PE County Code section 17-410 and Virginia Code §62.1-44.15:34 requires the VSMP authority to act on any VSMP permit by issuing a project approval or denial. This project is denied for reasons listed below. The VSMP application content requirements can be found in County Code section 17-401. A. Stormwater Pollution Prevention Plan (SWPPP) The SWPPP content requirements can be found in County Code section 17-405. A SWPPP must contain (1) a PPP, (2) an ESCP, (3) a SWMP, and (4) any TMDL measures necessary. SWPPP 1. Please ensure SWPPP cover includes reference to WP02021-00069. (Rev. 1) Addressed. 2. Submit SWPPP using county template located at: httos://www.albemarle.org/home/showpublisheddocument/ 166/637202310327530000 a. Sec. 1: Registration Statement; please complete. Feel free to call if any questions. (Rev 1) Addressed. As ollow-e p: i. Recommend revise Sec. IIG., estimated start date. b. Sec. 6.A.: PPP Exhibit: Please show initial location of: (Rev. 1) Addressed except please see vii. i. Rain gauge. ii. Portable sanitary facilities (porta-john), as required. iii. Covered non -hazardous waste dumpster, if required. iv. Vehicle wash waters, draining to trapping measure (Not a sediment trap design, per se, but shallow depression — 1-2 backhoe buckets. Avoid direct drainage to Ex, storm system, or pond/s.) v. Concrete wash -out. vi. On -site fuel, if required. vii. Paint, stucco, chemical storage, if required. (Rev. 1) May persist. Although PPP key identifies this item, PPP Exhibit does not appear to show location, unless overlooked. c. Sec. 6E: List named individual responsible for PPP measures. (Rev. 1) Persists. Please list an individual responsible for pollution prevention practices prior to state permit issuance /prior to preconstruction. d. Sec. 8: Although county personnel will inspect, Applicant is required to retain qualified (contractor/third-party) E&S inspection personnel to perform ESC inspections and evaluate compliance relative to VESCH, 3rd Edition, 1992. (Rev. 1) Persists. Please list an individual Engineering Review Comments Page 2 of 5 responsible for VESCH compliance inspections prior to state permit issuance /prior to preconstruction e. Sec. 9: Ensure Signed Certification is signed and dated. (Rev. 1) Addressed. f (Rev. 1) New: i. Sec. 11 —Please include 26-p. 2019 VAR10 CGP at Sec. 11 of SWPPP. ii. Sec. 4 requires I I" x 17" ESC plan sheets. Please provide. iii. Sec. 5 requires I F x 17" SWM plan sheets. Please provide. B. Pollution Prevention Plan (PPP) —see SWPPP item 2.b., above (Rev. 1) Please see A.2.b.vii above. The PPP content requirements can be found in County Code section 17-404. C. Stormwater Management Plan (SWMP) VSMP Regulation 9VAC25-870-108 requires the VSMP authority to approve or disapprove a SWMP. This plan is disapproved for reasons listed below. The stormwater management plan content requirements can be found in County Code section 17-403. 1. Bioretention that receives `runoff from hotspot land uses should not be treated with infiltrating bioretention (i.e., constructed without an underdrain).' Ref. VA DEQ Stormwater Design Specification, p. 15 of 54, Hotspot Land Uses. Provide `an impermeable bottom liner and an underdrain system,' per DEQ design specification for hotspot land use. (Rev. 1) Addressed. Applicant response (4/21/22 letter): `An impermeable liner and underdrain system are now shown for the bioretention basin.' 2. Show and label bioretention Level 1 pre-treatment on C6 profile. Ref. VA DEQ Spec. 9, Table 9.3. (Rev. 1) Addressed. 3. Include VA DEQ Specification No. 9 Table 9.6 Bioretention Material Specifications on the plan. (Rev. 1) Addressed. 4. Include VA SWMH Inspection guidelines for bioretention on the plans —sent to Applicant as .PDF. (Rev. 1) Addressed. 5. Include VA DEQ Specification No. 9 Bioretention installation, maintenance, and periodic inspection measures on the plan; these items begin at p. 34 of DEQ Design Specification No. 9. https://swbmpvwrrC.wp.I)rod.es.cloud.vt.edu/wt)-content/uploads/2017/ 11 BMP-Spec-No- 9 BIORETENTION vl-9 03012011.12df (Rev.1)Addressed. 6. Include Construction Record Drawings (As -built) for VSMP document on the plans, link: https://www.albemarle.org/home/showpublisheddocument/3381/637327510536700000 (Rev. 1) Addressed. 7. C3 a. Show carwash wastewater discharge line in plan and profile, between carwash and sanitary collection (San. MH). (Rev. 1) Addressed. b. Wherever storm runoff concentrates against curb, provide and label curb/gutter, CG-6. (Rev. 1) Partially addressed. In some locations where grade concentrates storm runoff against curb, design appears to propose CG-2. Please replace CG-2 with CG-6 wherever proposed grade concentrates storm runoff against curb. 8. Provide letter of nutrient credit availability for proposed 0.96 lb. nutrient credit purchase. Nutrient credit purchase is not required for WPO plan approval, but is required to receive a Grading Permit. (Rev. 1) Addressed. 9. C6 a. Provide detention pond 22 LF emergency spillway detail (plan/profile), (Rev. 1) Addressed. b. Provide bioretention planting plan, see VA DEQ Specification No. 9, Table 9.3. (Rev. 1) Addressed. c. Label bioretention and detention pond critical elevations, for example: floor of each facility, stone layer INV, riser INV. If riser INV = 2.5" control orifice INV Elev. 396.00, please state this. (Rev. 1) Addressed. Engineering Review Comments Page 3 of 5 d. Provide detention pond riser foundation detail, provide buoyancy calculations. (Rev. 1) Addressed. e. Provide embankment Notes /design: cutoff trench, anti -seep collar details, etc., for detention pond. (Rev. 1) Addressed. f Label bioretention basin and detention pond side slope (3: 1, for example). (Rev. 1) Addressed. g. Request exception from Min. 3" orifice size, examine alternative designs that permit Min. 3" orifice size. (Rev. 1) Addressed. Applicant: `The design has been modified to allow for a 3" control orifice instead of 2.5".' h. (Rev. 1) New: Recommend label L, DIA, % slope, etc. for blue -circle pipes /structure/s between bioretention and detention basin. TO ELEV M .00 CONE. STANDIPPE _ 10 rR wsF 405. 31 1 yR 44" — — — — — ELEV, a00.00— f/jilli - — — — — — —_— to wt yE 3%1.59 OF FILTER MEDI ,INSTALL 1107. IE. TOP 404.50 OPPOSITE OF DAM X I CONC. BASE DEPTH, TOP SF VDOT 5] STONE 402 IMVLKMLAbLE LINER LINER AT BI 10. C 10: Label detention pond outfall riprap dimensions, L x W x D. (Rev. 1) Addressed. 11. Provide 36" riser low -flow orifice debris cage, and debris cage detail. (Rev. 1) Addressed. 12. C L Revise plan title to include ref. to WPO202100069. (Rev. 1) Addressed. 13. Calc. packet a. Revise title pg. (letter d. 12/7/21) to include ref. to WPO202100069. (Rev. 1) Addressed. b. Pg. 36 of packet /VaRRM.xls indicates 0.12 Ac. forest /open space post -developed land cover. Provide deeded easement for 0.12 Ac. (FOS easement), else revise VaRRM.xls post -developed land cover table to reflect 0.0 Ac. forest /open space. Adjust SWM approach, as needed, to meet water quality compliance requirements at 9VAC25-870-65. (Rev. 1) Persists. Applicant: `An open space easement will be provided in the plat for this development.' 14. Provide SWM facility /Access easements via separate easement plat application. Link to application: https://www.albemarle.orp/home/shQnublisheddocument/1052/637624089314100000 (Rev. 1) Partially addressed. Applicant: `A SWM facility /access easement will be provided and submitted in a new plat.' As ollow-up: Review comment ambiguous. Please provide a SWMfacility easement in addition to SWM facility access easement. Provide linework /label `VAR width SWM facility easement.' 15. Provide and label SWM facility access. See requirements at ACDSM, p. 12. Best Management Practices for Stormwater Management. Provide mountable curb and other minimum features required for vehicular access to detention pond dam. (Rev. 1) Partially addressed. Proposed SWM facility access (sheet 04) is centered on a DI, which invites damage to structure /vehicles. Provide a reasonable SWM facility access free of conflict. Provide mountable curb traversable by a typical vehicle. 16. Note: Easement plat must be recorded prior to WPO plan approval. (Rev. 1) Persists. Applicant: `Acknowledged, the plat will be recorded prior to approval.' 17. Note: SWM facilities are located on TMP 130A1-00-00-047B0; owner of TMP 130A1-00-00-047BO is a required party to SWM Facility Maintenance Agreement, and WPO plan bond. (Rev. 1) Persists. Applicant: `Acknowledged, these parcels share the same property owner.' Engineering Review Comments Page 4 of 5 D. Erosion and Sediment Control Plan (ESCP) Virginia Code §62.1-44.15:55 requires the VESCP authority to approve or disapprove an ESCP. This plan is disapproved for reasons listed, below. The erosion control plan content requirements can be found in County Code section 17-402. 1. Provide labels that distinguish which is sediment trap 1, which is ST2, consistent with Cl 1 ST tables. (Rev. 1) Addressed. 2. STl adjacent to Valley Street, Rt. 20: Please increase trap size so that ST failure is less likely, and any failure is less severe. Roadside ditch -line topography may not readily accommodate release of sediment - laden water. Please target 25% increase above minimum required volumes. If design volume is the strict design minimum, then any failure will be hard to remedy. It will be difficult to increase trap size, later. (Rev. 1) Addressed. 3. Include paved wash rack detail on plans; ref. p. 8, ACDSM, link: https://www.albemarle.org/Home/ShowDocument?id=270 (Rev. 1) Addressed. 4. C8 C9C9: Provide silt fence between diversion dike and Rt. 20. (Rev.1) Addressed. 5. C8 (Rev. 1) Addressed. a. Label trap floor dimensions. b. Indicate stockpile location, if any. (Rev. 1) Applicant: `Stockpiles are not anticipated for this site.' c. Area upslope of SF along southwest limits of disturbance exceeds 100 LF. Revise to provide additional or alternative VESCH measures, since upslope length above SF is 100' Max. d. Label drainage areas for each trap that correspond with Cl 1 DAs (1.36, 0.84 Ac.). 6. Provide interim ESC plan and sequence that anticipate ESC measures required to transition ST2 to a detention pond while maintaining adequate ESC that prevents off -site sediment release. Phl ESC plan shows a perimeter sediment trap. Ph2 ESC shows biofilter, and a detention pond that occupies sediment trap (ST2) location without any indication how site runoff will be controlled as site transitions from Phl to Ph2. During transition, site runoff must be controlled with adequate ESC measures at south edge of site. (Rev. 1) Partially addressed. As follow-up: a. CC 11 Sequence Note 6: May include typo — `... until road construction is complete... ' No road proposed with this development. b. CC 1 Note 7: Please revise ref. to C9 to ref. sheet CC 1 instead. 7. Provide Note that bioretention may not be constructed until all upslope areas are stabilized. (Rev. 1) Addressed. 8. Provide SAF along Rt. 20 and Rt. 726. (Rev. 1) Not addressed. Please provide safety fence (SAD along Rt. 20 and Rt. 726. 9. If unbalanced cut/fill site, if export is required, please note destination for off -site export. (Rev. 1) Addressed, Process: After approval, plans will have to be bonded. The bonding process is begun by submitting a bond estimate request form and fee to the Department of Community Development. One of the plan reviewers will prepare estimates and check parcel and easement information based on the approved plans. The County's Management Analyst will prepare bond agreement forms, which will have to be completed by the owner and submitted along with cash, certificates or sureties for the amounts specified. The agreements will have to be approved and signed by the County Attorney and County Engineer. This may take 24 weeks to obtain all the correct signatures and forms. Stormwater Management Facilities Maintenance agreements will also have to be completed and are recorded. The County's Management Analyst or other staff will prepare the forms and check for ownership and signature information. The completed forms will have to be submitted along with court recording fees. Engineering Review Comments Page 5 of 5 This project proposes nutrient credit purchase (0.96 lbs.) and requires SWM facility and SWM facility access easements. This project may also require forest -open space easement (for SWM purposes). After bonding and agreements are complete, county staff will enter project information in a DEQ database for state application processing. DEQ will review the application information based on local VSMP authority approval. At this time, the DEQ portion of the application fees will have to be paid directly to the state. For fastest processing, this is done electronically with the emalls provided on the application. DEQ should notify applicants with instructions on how to pay fees. When DEQ approves the application, they will issue a permit coverage letter. This should be copied to the county. After DEQ coverage is issued, via the coverage letter, the County can hold a pre -construction conference. Applicants must complete the request for a pre -construction conference form, and pay the remainder of the application fee. The form identifies the contractor and responsible land disturber, and the fee remaining to be paid. This will be checked by county staff, and upon approval, a pre -construction conference will be scheduled with the County inspector. At the pre -construction conference, should everything proceed satisfactorily, a joint VSMP and grading permit will be issued by the County so that work may begin. County forms can be found on the county website forms center under Engineering Applications: httos: //www.albemarle. org/government/community-develonment/aooly-for/engineering-auol ications Thank you. Please call if any questions — tel. 434.296-5832-x3069, or email 4anderson2(a)albemarle.org. WPO202100069_Scottsville Tiger Fuel Mkt _052022revl