Loading...
HomeMy WebLinkAboutARB202200053 Plan - Submittal (First) 2022-05-23US CEL LAR PPROVAL: Date. 4/6/2022 David Diaz Construction & Design Mqr. II MAV 4f,;< LANDLORD APPROVAL: Date. sceii iar. SITE ADDRESS: 1885 Seminole Trl Ste 100 Charlottesville, VA22901-1160 CITY CODE: LANDLORD CRITERIA: The allowable square footage for main front was sign is1.5 sq. ft. To be Determined per linear foot of store frontage and .50 sq ft per linear foot of the store side. Per Jeff Baker US Celluar can have equal to or less square footage and is grand -fathered in. LOCATION #: VA187 PROPOSED SIGNAGE: etter on Backer w/ Raceway 82.6 Letter on Backer wl Raceway 42.3 SITE PLAN NTS - Not to Scale CLIENT: OROERNUMBER wuscellular. 16 NAM R ELECTRONIC RLE NPME 2 G NCCOUNr UWS CELLI PROJECT NUMBER ans vvaEcrw,NnBER EVELTN NEGRON STOREFRONT ELEVATION Scale: 3I16"=1'-0" USC-CL-RWY-BP34 EXISIINGSIGNSP 97.0 PROPOSED SIGN SF: 626 wnu caoR: Ili O SW 6aBB-Pizazz PexA CLIENT I PROJECTNVMBIR I R- Re,N IDe ARiS[ Dpspnpbm fl6B541 4255 On mal 3zswt OYnIn TB V uscellular - .t11FNVMBR PROJECT MANAGER. ADDRESS 0RAGE Noy VA1e1 EVELYNNEGRON 1 -r-- ---- ---- EX6TING 4'-WALL OBE EPAIREDAS REDUIR Dg REPLACED FACE LIT CHANNEL LETTERS on backer Scale: 3/8"=1'-0" USC-CL-RWY-BP-34 FOUR LINE = 82.6 square feet e-r e+ — L---- — 18'-11-11/16" rovGrv'wcns mrn PoINi OF LOGO _ 4'-3" T-7-11/16 L sTusIc I!U la, L14'-10-1/4" FACES: 3116" 92447 White acrylic faces w/ surface applied vinyl; Vinyl to be inset around edges of letters TRIMCAP: i" standard White jewelite Trimcap RETURNS: 4" deep .040 alum returns — Pre -finished White BACKS: 3mm white ACM backs ILLUM.: Qwik Mod 2 / 71 o0K/ 12 volt LEDs as required; Power supplies housed with raceway BACKER: .080 thick aluminum backer panel — Pre -finished While TM: Surface applied die -cut vinyl applied directly to backer WALL MAT: Dryvit RACEWAY: Custom formed raceway for logo; 8-1/2" x 4-318" Low -Profile aluminum extruded raceway for Letters; Raceway to house all electrical; Painted white to match backer INSTALL: Thru bolted using all thread into blocking as required 12" standard length of threaded rod will be supplied unless otherwise noted; 3/8" threaded rod into blocking or Stratus approved equivalent Compresion sleeves required to avoid crushing the wall during install QUANTITY: (1) ONE SET REQUIRED FOR STOREFRONT ELEVATION -----------49OLOR PALETTE}- --- --- FACES: FACES Pantone 1T88 Red tIfM: Panlone 286 Blue 3M 3636-163 Scarlet Red 3M 3630-978NW1 Blue ORETURNSrFRIMCAPIBACKERIRACEWAY: While CLIENT 1666<1 YX uscellular. SITE NUMBER ADDRESS 11 PAGE NO 0 VA187 ELECTRONICFlL`SwCFm 4 GNCCONNTSINIIS CELLII PROJECTNDMBER. 4265 PRDIECTj` ND ER EVELYN NEGRON 34" keyline=.356" TM 33�ker outline=2.8" oil ii M. 11_e .e l„�maeN «nu,awm�mM.. 3 �'m N. ,I1 O. nenum rmxiwPRin'n 'nlrn e r nP 6 soumym W Sara ra u-1 Vam MroN e irc[un uo Lo m N e R @s I1 rW.�tt"M1de M prc-frvsMy moil. 13 pN! i. ENsam�"w,a�� s ,�"m wm�azA.mv