Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ARB202200052 Plan - Approved 2022-06-14
10 .L Timberland b� Park APartmemsv V =, The Woodlands of Chadottesvllle 4n "Op^amwaM ad s 34 ad gb P� kna reeece 5 ry kn N.H. 4 e] 3 ^m"'a Re V 9Mad Billing p Villas At Southern Ridge P%,, ewm'YC.apr Fe Br00kdae Apdrtm¢m5 r' Pd ❑. Co�ntrYG�� Country G.p� rS y � 5 Oak HIII Market & Dell cmieemameamm d C c ooi9P P Is e ,IJ1ey 0r P O 3 Q nx Pve R ¢ 4 O e6 perej9 i °leG.i The n w` PERMIT PACK / PROPERTY LINES 4+a. Par4 qE Q AZALEA Azalea Park- PARK Park & Ride e'gpa'kwry sports rielrle QAzalea Park MlC a°�eY9`Wne N DBAZS336 fps QWMPoWay crossing F F s Fifth Street Place Q AparVnents 5th SI FEE Cooperative Extension Office Albemarle Registrar of Voters a. Albemarle County of So Department of Social... Pd s' Client: Storage Sense Approved Mrnrn Location: 3030 Vision Lane, Charlottesville, VA 22903 ♦N 3 • - ----- Channel Letters ar- ii n ® _I I lei I I I I I I ILII STO Y fWfwxi GpA'O.Gtle N"a. � f Letters i Channel I lei - Letters PERMIT PACK / SITE MAP Client: Storage Sense Location: 3030 Vision Lane, Charlottesville, VA 22903 Approved MMM O6/102022 2 26 26 PM )fN PROPOSED SIGNAGE SOUTH EXTERIOR ELEVATION w 0 O 2 230' Overall Length INSTALLATION METHOD Building Wall Logo Capsule & Channel Lette Side Vi PERMIT PACK - Channel Letters - Set 1 1 Size: 36"H x 212"W - 53 SgFt Channel letter/Logo Flush Mounted to Raceway. Raceway Flush Mounted to Building Wall by Lag Screws w/Shields. Power Supply (UL Listed) inside Raceway, with (UL Listed) Disconnect Switch. Client: Storage Sense Approved MMM Location: 3030 Vision Lane, Charlottesville, VA 22903 06/141202222635 PM z Sign Specifications - Company ID Sign Trim: Black Face: Digital Prints - Pantone 202c Returns: Black Mounting: Raceway Mounted Raceway Color: Raceway color will match the color of the wall to which it is attached. 3' 2'-2" (36") (26 ) (O.H.) ora( PERMIT PACK 17'-8.75" (212.75") Overall Length Material & Color Legend Returns Trim Vinyl LED Module MEN� Black Black Digital Print Red (16.25") e bo Sense 1'-10.51, 2'-5J51 'Y (29.75") Client: Storage Sense Approved MMM Location: 3030 Vision Lane, Charlottesville, VA 22903 061141202222646PM © PROPOSED SIGNAGE EAST EXTERIOR ELEVATION 48'Overall Length INSTALLATION METHOD Building Wall Logo Capsule & Channel Lette Side Vi PERMIT PACK - Channel Letters - Set 1 i Size: 36"H x 212"W - 53 SgFt Channel letter/Logo Flush Mounted to Raceway. Raceway Flush Mounted to Building Wall by Lag Screws w/Shields. Power Supply (UL Listed) inside Raceway, with (UL Listed) Disconnect Switch. Client: Storage Sense Approved MMM Location: 3030 Vision Lane, Charlottesville, VA 22903 06"4,2022226=7PM a Sign Specifications - Company ID Sign Trim: Black Face: Digital Prints - Pantone 202c Returns: Black Mounting: Raceway Mounted Raceway Color: Raceway color will match the color of the wall to which it is attached. 3' 2'-2" (36") (26 ) (O.H.) ora( PERMIT PACK 17'-8.75" (212.75") Overall Length Material & Color Legend Returns Trim Vinyl LED Module MEN� Black Black Digital Print Red (16.25") e bo Sense 1'-10.51, 2'-5.75t)-00 (29.75" Client: Storage Sense Approved MMM Ofi/10202222] 05 PM Location: 3030 Vision Lane, Charlottesville, VA 22903 PROPOSED SIGNAGE 230' Overall Length INSTALLATION METHOD Building Wall Logo Capsule & Channel Lette Side Vi PERMIT PACK - Channel Letters - Set 1 Size: 71.5"H x 188"W - 93 SgFt Channel letter/Logo Flush Mounted to Raceway. Raceway Flush Mounted to Building Wall by Lag Screws w/Shields. Power Supply (UL Listed) inside Raceway, with (UL Listed) Disconnect Switch. Client: Storage Sense Location: 3030 Vision Lane, Charlottesville, VA 22903 Approved MMM 0&prov 22]13PM 0 Sign Specifications - Company ID Sign Trim: Black Face: Digital Prints - Pantone 202c Returns: Black Mounting: Raceway Mounted Raceway Color: Raceway color will match the color of the wall to which it is attached. 2' (3 15'-8"(188") Overall Length dens PERMIT PACK Material & Color Legend Returns Trim Vinyl LED Module MEN Black Black Digital Print Red Client: Storage Sense Location: 3030 Vision Lane, Charlottesville, VA 22903 A1&1112 tl MMM ocn arzozz zn n am 5" This Sign will be installed in strict compliance with the (US) National Electric Code (Article 600) including The UL 48 Standard (or equivalent), and with local city, county and state codes within the jurisdiction of this Sign Project. All parts of this electrical, illuminated Sign will be properly grounded and bonded (as required). Building Fascia: Brick Existing Building Fascia / Wall Note: Section View of Detail is Exaggerated for Viewing Purposes Only Letter / Logo Return:.040" thick Metal Painted Black with Satin finish Trim Cap: 1" wide Plastic to be Black Channel Logo & Letter Face: 3/16" thick White Acrylic. Red Translucent Vinyl Overlay Letter / Logo Back: White ACM For Logo & Letters: Red LED Lighting Modules (UL Listed) Atadied to Back of Letter / Logo Fastened Letter to Raceway Ground Screw, Grounding Grounding Note: All Metal Parts of Signage to be Properly Grounded Incoming Insulated Wiring to LED Lighting Modules Text Capsule to be 3/16" thick White Acrylic Face with Red Transl. Vinyl Overlay (Channel Letter / Logo Flush Mounted to Raceway; Flush Mounted to Building Fascia / Wall) Attachment Detail Not to scale PERMIT PACK Drain Holes 5" --� 4-1)2" 1 Important Note for Fabricator & Installer: All (custom) sign and sign related work to strictly adhere to NEC Code, the UL 48 Standard (or equivalent) requirements, and local (AHJ) requirements. Note: Authority Having Jurisdiction (AHJ) Material Type: ALL ELECTRICAL varies Important Note: COMPONENTS Depth of wall: Suitable for Wet, Dry & ISTE Varies Damp Areas o Raceway to be Aluminum fabricated MET rr7z--5" Deep - Painted to Match Bldg Color c us This product is Classified by MET as to Power Supply (UL Listed) inside Raceway the properties of product tested(only) Pigtails for Wiring I I-* Section - Lag Screws w/Shields, Min. I I I I--)- Section Wall Penetration fill with Silicone Detail Note: Actual Color of Sign May Not Be Shown on Attachment Detail Disconnect Switch (UL Listed) Located on Junction Box betw. Power Panel & Power Supply ,5 Rigid EMT Conduit / Primary Electrical Source from Dedicated Circuit One (1) Circuit to be: 20 Amp, 120 Volt Disconnect Switch (UL Listed) Located on Raceway Return Grounding Note: All Necessary Sign Components to be Properly Grounded Section View Front -Lit Channel Letter on a Raceway Code 600.4, Conforms: Markings on Signs Code 600.5, Conforms: Branch Circuits (Other Signs & Outline Lighting, not to exceed 20 A) Code 600.6, Conforms: Disconnects Code 600.7, Conforms: Grounding & Bonding Code 600.6, Conforms: EAGIGOWFeS Code 600.9, Conforms: Location Code 600.12, Conforms: Field -Installed Sec. Wring Code 600.21, Conforms:Ba"a,rs, nsfefffue.T Electronic Power Supplies & Class 2 Power Sources Code 600.23, Conforms: 3sansferaers&Electronic Power Supplies Code 600.24, Conforms: Class 2 Power Sources Code 600.30, Conforms: Applicability Code 600.33, LED Sign Illumination Systems, Secondary wiring Code 300, Conforms: Materials & Fasteners Et Cetera... 1. Penetrations thru Surfaces to be Watertight 2. Illumination from Sign to be "Even Lighting' 3. Lighting Devices to produce "Consistent Light" 4. All Signage to be MET Listed, Classified 5. Fasteners and Related to be Non -Ferrous Metals Power Device to be UL Listed, Classified Client: Storage Sense Approved Mill 3030 Vision Lane, Charlottesville, VA 22903 een.,a 22728PM