Loading...
HomeMy WebLinkAboutSUB202200107 Study 2022-06-30 (2)Page 1 of 12 GeoEnvironmental Services, Inc. MAOSE Report for Subdivision Approval Letter Location of property: Secretarys Ridge Lot 7; Part of Parcel ID:11900-00-00-05300; East Side of Secretarys Sand Road Albemarle County; Acreage: 7.54 ac; Applicant or Client and address: Prepared by OSE: Keith M. McQuiddy Lee's Branch LLC GeoEnvironmental Services, Inc. 206 South Avenue P.O. Box 1555 Harrisonburg, VA 22801 Mechanicsville, VA 23116 804-730-8220 Date of this report: 6/22/22 OSE/PE Job Number: n/a Revision Dates: n/a Health Dept. ID No.: n/a t-onrenrs or uus report: ® Health Department Application Form (p.2) ® Survey Plat (p.8) ® Abbreviated Design Form (p.3-4) ® Private Well Addendum (p.9) ® Soil Summary' Report (p.5) ® Owner/ Installation Contractor Notes (page 10-12) ® Soil Profile Descriptions Report (p.6) M Site Sketch Drawn to Scale (u.n I hereby certify that the evaluations and/or designs contained herein were conducted in accordance with the Sewage Handling and Disposal Regulations (12 VAC5-610), the Private Well Regulations (12 VAC5-615), and other applicable policies of the Virginia Department of Health. Furthermore, I certify that my evaluation and/or design contained herein complies with all applicable laws, regulations, and policies implemented by the Virginia Department of Health. The work attached to this cover page has been conducted under an exemption to the practice of engineering, specifically the exemption in Code of Virginia Section 54.1- 402.A.11. I recommend a Subdivision Approval be approved. OSE 4--7 /"`z 4'7—!L L # 1940 001299 Op rKEITIiM. McQUIDDYa Lie No. 1299 , 9��NSITE SO� *The OSE wishes to be contacted if a Level II review is necessary. Secretarys Ridge Lot 7 - Lee's Branch LLC - SAL Page 2 of 12 Commonwealth of Virginia VDH Use Only Health Department ID# Application for: X - Sewage System X -Water Supply Date Received Owner: Lee's Branch LLC Mailing Address: 206 South Avenue, Harrisonburg VA 22801 Agent: n/a Mailing Address: n/a Site Address: East side of Secretarys Sand Road Phone (540) 908-8757 Phone Phone Phone Directions to Property: From Albemarle County Health Department Get on US-250 W/US-250 BYP W from Rugby Ave 3 min (0.7 mi) Take US-29 S to N Garden Ln in North Garden 14 min (12.9 mi) Take Plank Rd and Alberene Rd to Secretarys Sand Rd in Schuyler 17 Subdivision: Secretarys Ridge Section: n/a Block: n/a Lot: 7 Part of Parcel ID: 11900-00-00-05300 Tax Map#: n/a Dimension/Acreage Of property 7.54 ac. Type of Approval: Applicants for new construction are advised to apply for a certification letter to determine if land is suitable for a sewage system and to apply for a construction permit (valid for 18 months) only when ready to build. X Certification Letter _ Construction Permit _ Voluntary Upgrade _ Repair Permit _ Minor Modification Proposed Use: Single Family Home (Number of Bedrooms 4 ) Multi -Family (Total Number of Bedrooms ) Other (describe) Basement? _Yes X No Conditional permit desired? Yes X-No Walk -out Basement? _Yes X No Fixtures in Basement? _Yes X No If yes, which conditions do you want _Reduced water flow _Limited Occupancy _Intermittent or seasonal use _Temporary use not to exceed 1 year Do you wish to apply for a betterment loan eligibility letter? _Yes X No ' A $50 fee for determination of eligibility. Water Supply Will the water supply be X Private or _Public? Is the water supply _Existing or X Proposed? If proposed, is this a replacement well?_Yes X No If yes, will the old well be abandoned? —Yes _No Will any buildings within 50' of the proposed well be termite treated? —Yes X No Well type (e.g. domestic use, agricultural, irrigation, etc.) Domestic Use All Applicants Is this property indeed to serve as your (owners) principal place of residence? _Yes X No All applications must be accompanied by private sector evaluations and designs, unless a petition for VDH services is approved. A petition for Service for attached? —Yes X No plat of the property is recommended and a site sketch is required. The site sketch should show your property lines, actual and/or proposed buildings and the desired location of your well and/or sewage system When the site evaluation is conducted the property lines, building location and the proposed well and sewage sites must be clearly marked and the property sufficiently visible to see the topography. I give permission to the Virginia Department of Health to enter onto the property described during normal business hours for the purpose of processing this application and to perform quality assurance checks of evaluations and designs certified by a private sector Onsite Soil Evaluator or Professional Engineer as necessary until the sewage disposal system and/or private water supply has been constructed and approved. Signature of Owner/ Agent Date Secretarys Ridge Lot 7 - Lee's Branch LLC - SAL Page 3 of 12 ABBREVIATED DESIGN FORM PRIMARY TYPE I - CONVENTIONAL GRAVITY DESIGN BASIS A. a. Estimated Percolation Rate: 50 min/inch b. Recommended trench bottom 18 in c. Depth to seasonal high water table or to limit of evaluation X 36 in d. Minimum separation required 18 in e. Separation distance in inches provided in design (Ac-Ab) 18 in f. Minimum trench bottom due to slope [(% slope-8)/2 + (12 or 18)) 18 in g. Is the slope greater than 10% No h. If Ag is Yes, does greater than 24 inches to rock exist below Ab n/ a i. If yes to Ah, add 1 ft. to the minimum center to center spacing beginning at 20% n/a slope and continue for each 10% slope increase above 20%. If no to Ah, add 1 ft. to the minimum center to center spacing beginning at 10% slope and continue for each 10% slope increase above 10%. (Report the value of the increase in center -to - center spacing above the minimum.) B. Trench bottom area required per bedroom (From Table 5.4 based on Gravity X LPD _ ): 376 sq.ft. C. Number of bedrooms: 4 TRENCH CALCULATIONS D. Length of Trench 70 ft. Length of Available Area 70 ft. E. Width of Trench 3 ft. F. Number of Trenches 8 G. Center -to -Center Spacing 9 ft. H. Width Required 66 ft. Width of Available Area 85 ft. I. Total Area Required (BxC) 1,504 sq.ft. J. Design Area (D x E x F) 1,680 sq.ft. K. Reserve Area Required? Yes X No a. Percent required 100% b. Percent available 100 % - see separate design on page 4 Secretarys Ridge Lot 7 - Lee's Branch LLC - SAL Page 4 of 12 ABBREVIATED DESIGN FORM RESERVE E-Z TREAT to PAD DESIGN BASIS Install Pad Bottom: 18 in. Estimated Percolation Rate: 50 min/in. Design Flow: 600 gal./dam Active Pad area required (600 gal/day) / (0.67 gal/day/sq.ft): 896 sq.ft. calculated using Table 1 of The Regulations far Alternative Onsite Sewage Systems (IT.-3 effluent quality) Septic Tank Size: 1250 gal X PERCOLATION AREA DESIGN Total Pad Area Required 896 sq.ft. Design Area 70' x 13' = 910 sq.ft. Length of Pad 70 ft. Width of Pad 13 ft. Pad Thickness 18 inches *Stone aggregate required MINIMUM SEPARATION DISTANCES To Bedrock or Impervious Strata 42 in. To Wetness Features n a in. Other Restrictions: limit of evaluation 36 in. Secretarys Ridge Lot 7 - Lees Branch LLC - SAL Page 5 of 12 SOIL SUMMARY REPORT SOIL INFORMATION SUMMARY Position in Landscape: Satisfactory X Unsatisfactory Slope: 7-9% Description: Proposed drainfield occupies an upland sideslope topographic position and has good surface drainage Depth to Rock or Impervious Strata: None Max. X Min. 42 Inches Depth to Seasonal Water Table (Gray Mottling or Gray Matrix Color): None X Inches Free Water Present: No X ;Range: Inches Soil Percolation Rate 50 min/inch Estimated X Field Test ; Soil Texture Group III Permeability Test Performed: No X Yes Recommended Trench Bottom 18 Inches Reserve Drainfield Required: Yes X No _ Percent Available Area 100% System Type: Gravity X Pump / Enhanced Flow Water Supply: Public ; Class IIIA ; Class IIIB ; Class IIIC X NOTE: See the site sketch for the location of the homesite, drainfield, well, and driveway (when applicable). Secretarys Ridge Lot 7 - Lee's Branch LLC - SAL Page 6 of 12 SOIL PROFILE DESCRIPTIONS REPORT Site Evaluation: March 30m, 2022 & April 2^ 2022 HORIZON DEPTH DESCRIPTION OF COLOR, MOIST CONSISTENCE, TEXTURE, STRUCTURE TEXTURE INCHES GROUP Boring# 21 A 0-3 Brown (10YR 4/3); friable; sandy clay loam IIB Bt 3-14 Yellowish red (SYR 5/6); friable; light clay loam III Bt 14-28 Red (2.5YR 4/6); friable; clay loam with few mica flakes present III 28-42 Red (2.5YR 4/6) mottled with common medium distinct strong brown (7.5YR 5/6), and 1113 BC black (10YR 2/1); friable; loam with mica flakes present 4246 Red (2.SYR 4/6) mottled with common medium distinct strong brown (7.5YR 5/6), and 1113 Cd black (10YR 2/1); chippy; loam with mica flakes present Boring# 22 A 0-7 Grayish brown (10YR 5/2); friable; sandy loam IIA 7-24 Yellowish brown (10YR 5/6) mottled with common medium distinct strong brown (7.5YR III IIB Bt 5/6) and reddish yellow (5YR 6/8); friable; light clay loam to loam - Yellowish red (5YR 5/6) to strong brown (7.5YR 5/6) mottled with common medium Bt2 24-36 distinct reddish yellow (5YR 6/8), brownish yellow (10YR 6/6), and yellowish brown IIB (10YR 5/6); friable; loam to micaceous loam Boring# 23 A 0-6 Brown (10YR 4/3); friable; sandy clay loam IIB Strong brown (7.5YR 5/6) to yellowish red (5YR 5/6) mottled with few fine distinct Bt 6-38 yellowish brown (10YR 5/6), and brownish yellow (10YR 6/6); friable; light clay loam III with few mica flakes present Yellowish red (5YR 5/6) mottled with common medium distinct reddish yellow (5YR 6/8), BC 38-50 yellowish brown (10YR 5/6), and brownish yellow (10YR 6/6); friable; light clay loam to III - IIB loam with many mica flakes present Variegated brownish yellow (10YR 6/6), yellowish brown (10YR 5/6), reddish yellow C 50-60 (5YR 6/8), yellowish red (5YR 5/6), and white (10YR 8/1) lithochromic parent material; IIB - IIA friable; micaceous loam to micaceous sandy loam Boring# 24 A 0-4 Brown (10YR 4/3); friable; sandy clay loam IIB Bt 4-40 Red (2.5YR 4/6); friable; clay loam with few mica flakes present III Red (2.5YR 4/6) mottled with common medium distinct strong brown (7.5YR 5/6), BC 4052 yellowish brown (10YR 5/6), and black (10YR 2/1); friable; loam to micaceous loam with IIB few parent material fragipans present 52-60 Variegated strong brown (7.5YR 5/6), yellowish brown (10YR 5/6), reddish yellow (5YR IIB Cd 6/8), red (2.5YR 4/6), and black (10YR 2/1); chippy; loam to micaceous loam Remarks: The soils of this site have developed from the weathering products of granite gneiss and mica schist of the Piedmont Physiographic Province. These soils are deep and well drained. This site occupies an upland topographic position and has good surface drainage. * The location of soil evaluation profile holes is shown on the site sketch, which accompanies this report. The site sketch includes the estimated or measured location of all known wells, sewage disposal systems, springs and structural features within 200 feet of the proposed drainfield and reserve drainfield sites. Secretarys Ridge Lot 7 - Lee's Branch LLC - SAL Page 7 of 12 SITE SKETCH Scale:1" =100' -9T. Proposed D/F Area LOT 8 5.84 Ac. Proposed 3BR Home Proposed IIIC Well Area Proposed 0 IIIC Well 0 Proposed Area Q 4BR Z Home LOT 7 7.54 Ac. B- 4 N Z PRI B-21 U B-22 U3 B-23 7-9% LOTS 11.45 Ac. Secretarys Ridge Lot 7 - Lee's Branch - SAL Page 8 of 12 Plat 666, rZ nTp GFID NDHTN VA-S SPL lfk iu�mgs TNTmT p 2 T 2mm2o CYO Secretarys Ridge Lot 7 - Lee's Branch - SAL Page 9 of 12 Addendum to OSF,/PE Certification Statement For Private Well Construction Permit Secretarys Ridge Lot 7; Part of Parcel ID:11900-00-00-05300, 7.54 Acres Instructions: Please check one box in 1-3 below. Statement templates for item #2 and #3 are on the following pages. The proposed well site shown herein, ❑ 1. Is located a minimum of 50 feet from all property lines. ® 2. Is located within 50 feet of the adjacent property line(s) but I have determined that the adjacent property is not used for an agricultural operation. ❑ i. Written affirmation from the adjacent property owner(s) that their property is not used for an agricultural operation. ® ii. Other confirmation that land use is not an agricultural operation, please describe: See recorded subdivision plat ❑ 3. Is located within 50 feet of adjacent property line where the property is used for an agricultural operation. For confirmation, I have attached the appropriate documentation pursuant to § 32.1-176.5:2 of the Code of Virginia. (check one below) ❑ i. Written permission from the adjacent property owner(s) for the well construction. ❑ ii. I certify that on other site on the property complies with the Board's Regulations for the construction of a private well. Secretarys Ridge Lot 7 - Lees Branch LLC - SAL Page 10 of 12 NOTICE TO OWNERS AND SEPTIC SYSTEM INSTALLATION CONTRACTORS GeoEnvironmental Services, Inc. (GESI) will be required to inspect the installation of the septic system and generate a completion statement for the health department. There will be a fee charged to the installation contractor for this inspection. Installation contractors may call GESI at 804-730- 8220 prior to bidding the installation of the system to determine fees for this inspection. A Completion Statement from GESI will not be released until our invoice for the inspection(s) is paid in full. GESI requires a minimum 48 hours notice be given prior to an inspection. It is recommended that as many of the components of the septic system as possible be installed, exposed, and operational during the inspection (including pumps) in order to limit the number of site visits. Failure to give an advanced notice of 48 hours to schedule an inspection may result in additional inspection fees for potential scheduling conflicts. Multiple site visits to inspect incomplete work or work that requires modifications will result in additional inspection fees. Virginia law requires all septic systems be installed by a DPOR Licensed Onsite Sewage System (Septic) Installer. Owners that contract with an installer that is not properly licensed may be subject to action that relieves the OSE and the septic system design Company from any and all liability for the performance of the sewage disposal system. Failure of the installation contractor to prepare the soil absorption area or install the sewage disposal system in accordance with the plans and specifications of the design professional will result in action that relieves the OSE and the septic system design Company from any and all liability for the performance of the sewage disposal system. Secretarys Ridge Lot 7 - Lee's Branch LLC - SAL Page 11 of 12 *ATTENTION* The installation contractor must install the sewage disposal system in accordance with the plans and specifications contained herein. No modifications or component substitutions should be made without prior authorization from the OSE. Failure to install the sewage disposal system as planned and specified by the OSE may result in action to void the permit. A pre -construction investigation may be required prior to the installation of the sewage disposal system. The installation contractor must contact the OSE prior to the installation to schedule the pre - construction meeting if there are any questions about the plans and specifications contained herein or the soil absorption area has been altered or impacted in any way. Soil absorption areas (drainfield) are very sensitive and require protection from grading and compaction or encroachment by heavy equipment and any other construction activity not related to the septic system installation. Regardless of the depth of the proposed installation, the soil absorption area is an extremely sensitive environmental resource that requires protection. The drainfield must be installed during "DRY SOIL CONDITIONS". It is important that clearing, grading and construction work in the vicinity of the drainfield be carefully planned to protect the septic system being proposed. The drainfield should be protected from vehicular and construction traffic and cannot be used for storage of construction materials. If trench lines in the drainfield are designed to be installed at 18-24" additional protection is required. No heavy machinery may be used to clear the drainfield. It is very important that the soils are not compacted and that topsoil is not removed during clearing. Wooded sites should have the leaf litter remaining after the trees are removed. Trees larger than 12 inches in diameter 3.0 feet above the soil surface are to be cut as near the soil surface as possible and the stump left in place. Stumps are not to be removed by excavation with a backhoe! Stump removal should be done with a stump grinder. The maximum depth of stump grinding is 18 inches below the natural soil surface. The site is not to be "root -raked". Secretarys Ridge Lot 7 - Lees Branch LLC - SAL Page 12 of 12 FACTS EVERY SEPTIC SYSTEM OWNER SHOULD KNOW Before installing your system: • Rope off the area of your system and protect it from vehicles. • Caution your builder to avoid system area during home construction. • Do not allow stripping of top soil or grading in the area of the system. • Do not allow system installation in wet or frozen soil conditions. Soil must be loose, dry, unsmeared, and uncompacted. • Keep downspout and Tooter drains out of your septic system. • Seed your system area as soon as weather permits. • Divert all surface water from system area. Conserve water: • Water conservation prolongs your system life, saves you money, and need not be a personal inconvenience. • Install low flow showerheads, faucet aerators, and install toilet bottle kits or tank displacement devices (if new construction purchase low flow commodes). These devices can save a family of four over 100 gallons per day. Cost for these devices is only about $20-70 and will save $100-300 each year. • See your local plumbing supplier and most major department stores. • Purchase a front loading washer, they use 1/3 less water than top loaders. • Take showers, they use less water than baths. • Promptly repair leaky faucets. • Use the clothes washer and dishwasher only when you have full loads. • Contact your local DER office for more information. Pump your septic tank: • Septic tanks must be pumped regularly (at least every 2-3 years) • Tank pumping helps prevent more expensive system problems. Waiting for evidence of system problems (spongy lawn or sluggish toilet) may be too late for pumping to help. • Pump your tank through large central manhole, not the small baffle opening. • Be sure tank pumper agitates tank contents before pumping. Solids and floating scum must be mixed before removal. • Carefully mark the location of your septic tank. • Sewage grinders and garbage disposals increase solids build-up in your tank. More frequent pumping should occur. • Never enter a septic tank. • Information on septic system maintenance can be obtained from the local VDH office. Helpful Hints: • Place a copy of your sewage permit and yellow application in a safe place. This information will be important for future use. • No septic tank additives have been proven beneficial for septic tank operation. Some may even be harmful. Regular tank pumping is the best advice to prolong your system's life. • Before repairing or replacing your system (even a new septic tank), a new sewage permit from the municipal sewage enforcement officer will be needed. Secretarys Ridge Lot 7 - Lee's Branch LLC - SAL