HomeMy WebLinkAboutSUB202200124 Plan - Submittal (First) 2022-07-11C 2022 - 30 SCALE, ULC
7
W
L11
Z
n
ABBREVIATIONS
AC ACRE
CFS CUBIC FEET PER SECOND
CG-12 ADA ACCESSIBLE CURB RAMP (VDOT STANDARD)
CIL CLASS
CO SANITARY SEWER CLEANOUT
CONIC CONCRETE
CY CUBIC YARDS
DB/PG DEED BOOKIPAGE
DEQ VIRGINIA DEPARTMENT OF ENVIRONMENTAL QUALITY
DIP DUCTILE IRON PIPE
E&S EROSION AND SEDIMENT CONTROL
EL, ELEV ELEVATION
EP, EOP EDGE OF PAVEMENT
ESMT EASEMENT
EW END WALL
EX EXISTING
FH FIRE HYDRANT
FPS FEET PER SECOND
GW GUY WIRE
HDPE HIGH -DENSITY POLYETHYLENE PIPE
HT HEIGHT
INV INVERT
L LENGTH
LAT LATERAL
LF LINEAR FEET
MAX MAXIMUM
MH MANHOLE
MIN MINIMUM
NTS NOT TO SCALE
PROP PROPOSED
RCP REINFORCED CONCRETE PIPE
SAN SANITARY SEWER
STA STATION
Svc SERVICE
SW SIDEWALK
SWIM STORMWATER MANAGEMENT
T TRANSFORMER
TBIR TO BE REMOVED
TC TOP OF CURB
TP TELEPHONE PEDESTAL
UG UNDERGROUND
VIDOT VIRGINIA DEPARTMENT OF TRANSPORTATION
VESCH VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK
VSMP VIRGINIA STORMWATER MANAGEMENT PROGRAM
WIVI WATER METER
WV WATER VALVE
RAGGED MOUNTAIN DRIVE
ENTRANCE MAINTENANCE PLAN
SYMBOLS
GRASS DITCH LINING PER VESCH 3.32
VIDOT STD. EC-3 DITCH LINING
-498--
—12—
CONTOUR LINE WITH ELEVATION
__1
27')
STORM SEWER STRUCTURE IDENTIFIER
(D
SANITARY SEWER STRUCTURE IDENTIFIER
_Q�
BENCHMARK, TEST PIT
GG
MANHOLE WITH FRAME AND COVER
+65 7
+ 65 Z-
SPOT ELEVATION
6x
ADA PARKING SYMBOL
WATER CROCKIMETER
4-
FIRE HYDRANT
0 WATER VALVE
WATERMAIN
SANITARY SEWER MAIN
STORM SEWER
PROPERTY LINE/RIGHT-OF-WAY LINE
CENTER LINE
FENCE LINE
EASEMENT LINE
ALBEMARLE COUNTY ENGINEERING GENERAL
CONSTRUCTION NOTES FOR PUBLIC ROADS
1 . Prior to any construction within any existing public right-of-way, including connection to any existing
road, a permit shall be obtained from the Virginia Department of Transportation (VDOT). This plan as drawn
may not accurately reflect the requirements of the permit. Where any discrepancies occur the requirements of
the permit shall govern.
2. Construction inspection of all proposed roads within the development will be made by the County. The
contractor must notify the Department of Engineering (296-5861) 48 hours in advance of the start of
construction.
3. All materials and construction methods shall conform to current specifications and standards of VDOT
All excavation for underground pipe installation must comply with OSHA Standards for the Construction
Industry (29 CFR Part 1926).
4. Erosion and siltation control measures shall be provided in accordance with the approved erosion
control plan and must be installed prior to any clearing, grading or other construction.
5. Upon completion of fine grading and preparation of the roadbed subgrade, the contractor shall have
CBR tests performed on the subgrade soil. Three (3) copies of the test results shall be submitted to the
County. If a subgrade soil CBR of 10 or greater is not obtainable, a revised pavement design shall be made by
the design engineer and submitted with the test results for approval.
6. All slopes and disturbed areas are to be fertilized, seeded and mulched. The maximum allowable slope
is 2:1 (horizontal:vertical). Where reasonably obtainable, lesser slopes of 4:1 or better are to be achieved.
7. Surface drainage and pipe discharge must be retained within the public right-of-way or within
easements prior to acceptance by VDOT. All drainage outfall easements are to be extended to a boundary line
or a natural watercourse. The contractor shall field verify the length of all storm drainage pipe.
8. Guardrail locations are approximate. Exact length, location and appropriate end treatments will be field
determined at the time of construction. Additional guardrail may be required at locations not shown when, in
the opinion of VDOT, the Director of Engineering, or the Directoros designee, it is deemed necessary. When
guardrail is required, it shall be installed four (4) feet offset from the edge of pavement to the face of guardrail,
and roadway shoulder widths shall be increased to seven (7) feet.
9. Where urban cross sections are installed, all residential driveway entrances shall conform to VIDOT
CG-9(A,B or C).
STATE ROUTE 860 (INTX WITH STATE ROUTE 637)
SAMUEL MILLER MAGISTERIAL DISTRICT
ALBEMARLE COUNTY, VIRGINIA
OF
EXIT 114
"IVY EXIT"
'S 64 ------ ..................... ......................
. ........ .
SITE
(P
,je. ro37
RAGGED
MOUNTAIN DRIVE
RTE. 1860
VICINITY MAP
SCALE: I "=2000'
11. Paved, rip -rap or stabilization mat lined ditch may be required to stabilize a drainage channel when, in
the opinion of VDOT, the Director of Engineering, or the Director:]s designee, it is deemed necessary.
12. A minimum clear zone of ten (10) feet from the edge of pavement shall be maintained on all residential
subdivision streets. Additional clear zone may be required depending on the category of road design.
13. Compliance with the minimum pavement width, shoulder width and ditch sections, as shown on the
typical pavement section detail, shall be strictly adhered to. The cross slope shall be maintained as shown on
the plans. Exceptions will not be allowed.
14. All required signs (stop, street name, speed limit signs, etc.) are to be furnished and installed by the
developer prior to acceptance Signs and their installation shall conform to "Albemarle County Road Naming
and Property Numbering Ordinance and Manual" and the Virginia Manual for Uniform Traffic Control Devices.
The locations of all signs are shown on the plans. The developer shall be responsible for maintenance of the
signs until the roads have been accepted into the state secondary road system. The speed limits to be posted
on speed limit signs are to be determined by VIDOT prior to acceptance. The speed limit is to be posted 5mph
below the design speed.
15. Road plan approval is subject to final subdivision plat validation. Should the final plat for this project
expire prior to signing and recordation, then approval of these plans shall be null and void.
16. Traffic control or other regulatory signs or barricades shall be installed by the developer when, in the
opinion of the Director of Engineering, or the Director's designee, they are deemed necessary in order to
provide safe and convenient access.
17. Use VDOT standard CD-11 or CD-2 underdrains under the subbase material at all cut and fill transitions
and grade sag points.
18. A video camera inspection is required for all storm sewers and culverts that are deemed inaccessible to
VIDOT inspections and are to be accepted into VDOT's maintenance program and ownership. The video
inspection shall be conducted in accordance with VDOT's video camera inspection procedure and with a
VIDOT and/or County inspector present. In addition, if high -density polyethylene (HDPE) pipe or pipe system is
installed, the contractor and a representative from the pipe manufacturer should hold a pre- construction
meeting for installation training. The pipe manufacturer should spend a minimum of two hours on the job site
during the initial pipe installation.
PROPERTY INFORMATION
TAX MAP AND PARCEL:
STATE R/W (ADJ TO TMP 74-5A1 & 74-5A2)
OWNER/IDEVELOPER:
RAGGED MOUNTAIN FARM POA
DISTURBED AREA:
1,500 SF
TOPOGRAPHIC SURVEY
COMMONWEALTH SURVEYING APR 2022
DATUM:
HORIZONTAL DATUM: NAD 1983, VA SOUTH
ZONE, VERTICAL DATUM: NVAD 1988
MISS UTILITY:
TICKET# A209600569 DATED 4/6/2022
CITY/STATE
ALBEMARLE COUNTY, VIRGINIA
ZONING:
RA
DEVELOPMENT AREA?
NO
FLOODPLAIN NOTE:
THE PROPERTY IS LOCATED IN ZONE "X",
AN AREA DETERMINED TO BE OUTSIDE
THE 0.2% ANNUAL CHANCE FLOOD PLAIN
AS SHOWN ON FEMA MAP NO.
51003CO265D, EFFECTIVE DATE FEBRUARY
4,2005.
RESIDENTIAL
SHEETINDEX
Sheet Number
Sheet Title
1
COVER SHEET
2
MAINTENANCE PLAN
SIGNATURE BLOCK
COUNTY ENGINEER
REVISIONS
# DESCRIPTION DATE
SCALE
E N G IN E E R I N G
owner:
RAGGED MOUNTAIN FARM POA
605 RAGGED MOUNTAIN DRIVE
CHARLOTTESVILLE, VA 22903
engineer:
30 SCALE, LLC
871 JUSTIN DRIVE
PALMYRA, VA 22963
p: 434.242.2866
e: mike@30scale.com
web: www.30scale.com
UJ
Z
D
0
2
0
W
(D
(D
Z
.J
a.
LU
Z
LU
F___
Z
LU
0
Z
ry
F___
Z
LU
(y)
ro
LU
0
Q�
LU
W
T_
X
C)
(0
00
LU
0
ly_
LU
C/)
heet title:
COVER SHEET
I scale: ASSHOWN
date: 06/30/2022
Z
0
Z
D
0
C)
w
W
D
0
_J
W
U)
w
_J
_J
2
_J
w
D
Lq
10. Where rural cross sections are installed, all residential driveway entrances shall conform to VIDOT
standard PE-11.
VIDOT
sheet#
1OF2
C 2022 - 30 SCALE, LLC
10
9
LIJ
2
<
z
CONSTRUCTION NOTES
1. PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT-OF-WAY,
INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED
FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT).
2. THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF
THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS OF THE
PERMIT SHALL GOVERN.
3. ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT
SPECIFICATIONS AND STANDARDS OF VIDOT UNLESS OTHERWISE NOTED.
4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND
MULCHED.
5. THE MAXIMUM ALLOWABLE SLOPE IS 2:1 (HORIZONTALNERTICAL). WHERE
REASONABLY OBTAINABLE, LESSER SLOPES OF 3:1 OR BETTER ARE TO BE
ACHIEVED.
6. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR
UNIFORM TRAFFIC CONTROL DEVICES.
CONTRACTOR RESPONSIBILITY NOTES
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY
PERMITS FOR CONSTRUCTION.
2. PRIOR TO COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR SHALL
VERIFY ALL PLAN DIMENSIONS AND THAT EXISTING SITE CONDITIONS ARE IN
CONFORMANCE WITH THE PLANS. IF ANY DISCREPANCIES ARE FOUND, THE
CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND ENGINEER TO
DETERMINE THE COURSE OF ACTION TO ADDRESS THE DISCREPANCY. THE
CONTRACTOR WILL BE CONSIDERED TO HAVE PROCEEDED AT THEIR OWN RISK
AND EXPENSE IF THEY DO NOT NOTIFY THE OWNER AND ENGINEER TO SECURE
GUIDANCE ON A CORRECTIVE ACTION.
3. THE CONTRACTOR IS RESPONSIBLE FOR THE RELOCATION OF ALL EXISTING
UTILITIES THAT ARE IN CONFLICT WITH THE WORK, INCLUDING EXISTING UTILITY
POLES AND GUY WIRES.
4. CONTRACTOR SHALL VISUALLY INSPECT CONCRETE FORMS PRIOR TO
PLACEMENT OF CONCRETE. IN THE EVENT THAT ADJUSTMENTS ARE NEEDED,
CONTRACTOR TO NOTIFY ENGINEER PRIOR TO PLACING OF CONCRETE FOR
FIELD REVIEW AND AGREEMENT ON ANY FIELD REVISION THAT MAY BE
REQUIRED. ENGINEER TO PROVIDE REASONABLE AND TIMELY RESPONSE TO
ALL INQUIRIES MADE BY THE CONTRACTOR.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL DURING
CONSTRUCTION, INCLUDING MAINTAINING UNOBSTRUCTED ACCESS FOR THE
RESIDENTS OF RAGGED MOUNTAIN FARM.
6. ALL DAMAGED EXISTING CURB, GUTTER, AND SIDEWALK SHALL BE REPAIRED
PRIOR TO ACCEPTANCE OF COMPLETED IMPROVEMENTS.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE ENGINEER
IMMEDIATELY IF UNKNOWN UTILITIES THAT IMPACT THE CONSTRUCTION ARE
DISCOVERED.
8. CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS TO AN EQUAL OR BETTER
CONDITION THAN EXISTED BEFORE CONSTRUCTION.
9. CONTRACTOR TO REMOVE ALL CONSTRUCTION DEBRIS FOLLOWING
COMPLETION OF CONSTRUCTION AND IMMEDIATELY REMOVE CONSTRUCTION
DEBRIS AND MUD THAT HAS BEEN TRACKED ON TO THE SURROUNDING
PROPERTIES.
10. CONTRACTOR SHALL BE LIABLE FOR REPAIR OF ANY DAMAGES ON PUBLIC OR
PRIVATE PROPERTY CAUSED BY HIS CONSTRUCTION ACTIVITY, INCLUDING
CURBS, GUTTER PAN, ASPHALT AND CONCRETE PAVEMENT.
2016 ROAD & BRIDGE STANDARDS
NOTES:
1 THIS ITEM MAY BE PRECAST OR CAST IN PLACE.
2. CONCRETE TO BE CLASS A3 F CAST IN PLACE,
4000 PSI IF PRECAST.
3. CURB HAVING A RADIUS OF 300 FEET OR LESS
(ALONG FACE OF CURB) WILL BE PAID FOR AS
RADIAL CURB.
4. THE DEPTH OF CURB MAY BE REDUCED AS MUCH
7
4"
;4
AS 3" (15" DEPTH) OR INCREASED AS MUCH AS
D
3" (21" DEPTH) IN ORDER THAT THE BOTTOM
OF CURB WILL CONCIDE WITH THE TOP OF A
COURSE OF THE PAVEMENT SUBSTRUCTURE.
OTHERWISE, THE DEPTH IS TO BE 18" AS SHOWN.
NO ADJUSTMENT IN THE PRICE BID IS TO BE MADE
FOR A DECREASE OR AN INCREASE IN DEPTH.
C0-2 IS TO BE USED ON ROADWAYS MEETING
THE REOUIREMENTS FOR CG-6 AS SHOWN IN
APPENDIX A OF THE VOOT ROAD DESIGN MANUAL.
IN THE SECTION ON GS URBAN STANDARDS.
A
6
RAMS
J.4
C' . r� SURF�
;A ;A
AS
;A ;a BASE
ACCEPTABLE ALTERNATIVE
IF CURB IS EXTRUDED
ERENCEI STANDARD 6" CURB
105
502 VIRGINIA DEPARTMENT OF TRA14SPORTATION
2016 ROAD & BRIDGE STANDARDS
VDOT STD. CG-2 DETAIL
R
CG-2
SURFACE
BASE
SUBBASE
ROAD AND BRIDGE STANDARDS
REVISION DATE 1 SHE I
T OF I
L201�07
30 38
82 82
EX EX
WP-2
EXISTING EDGE OF
PAVEMENT(WB)
40
82 ffx- 824-0-
EXISTING EDGE
82 15 OF PAVEMENT - 19
EX TAPER LANE 82
+ + EX 8217-
+ EX
0+77 END CURB CONSTRUCTION
TO MATCH EX. GRADE WITH
- .682 1
- NIOSE-DOWN CURB
85
81- EX
81 �-5 82
TIC 6
TIC
�2
81 +
EX
-681 82
*ft%
-681
EX. DITCH 5
TIC
822
LINE �SGN
96'
_��82 I� �7327'00" E 223.
__7
STATE ROUTE 637
DICK WOODS ROAD
VARIABLE WIDTH PUBLIC RIGHT-OF-WAY
DB 644 PC 334
HWY IX PC 204-208
38
82
EX
PROPOSED SAW GUT LINE IN
ACCORDANCEwITH VDOT
STD. WP-2, FIELD ADJUST A
NECESSARY S
09
82 ffx- 16
+ 82 _ +
EX
-
0+63.48=
82 �-9
EX
7
823N
Tz , "
PCC TC
81 83
EX Tcy
0
PROP. CG-2 12, ell
82
NOTE: CONTRACTOR TO PROVIDE
MAINTENANCE OF TRAFFIC PLAN
PRIOR TO ISSUANCE OF VIDOT LAND
USE PERMIT.
47
82 fc-
11
82�-' 82
EX EX
0+97 - END CURB
CONSTRUCTION TO MATCH EX.
GRADE WITH NOSE-DOWN-eURB
11� 89
82 T5-3C 81
--------- EX
'OF
Now 681
-\- EXISTING EDGE
-OF PAVEMENT -
-
-
EX. DITCH
LINE
N 73-26-59" E 436.05'
�
IF(HELD) 0+43.65= ZIGN\
STOP
10'DRAINAGE EASEMENT PCTC SEED AND STRAW ALL
DB 4029 PIS 496-511 SEED AND STRAW ALL DISTURBED AREAS BEHIND NEW
DISTURBED AREAS BEHIND NEW 73
CURB ONCE AT FINAL GRADE 81 TIC CO CURB ONCE AT FINAL GRADE
8118
TIC38 J1
rC
36
81 ER
PID 07400-00-00-005A2
ANGELO LEIGH MAURELLI AND BENCHMARK
KRISTEN PAIGE HAMILTON NAIL SET
NAIL ELEV=682.89
LOT A3 812 1
i TIC 81 ��2 / I I bB'5-
INST 202000000530 TIC I - -
DB 5266 PC 733 PID 07400-00-00-005AI
IR 0+27.37 ANGELO LEIGH MAURELLI AND
PC TIC 6BA OCT
KRISTEN PAIGE HAMILTON
LOT A3
EXISTING SUBDIVISION V0.11 0. 7A INST202000000530
STONE ENTRANCE C�
r� I= `3
FEATURES
CID
cz C:�
80 L2 cz
TIC
CIO
Lo
Cc
59
9
X X X TC Do
0
37
i0+00 80:NrC TC1
92
.. 79 EX c�o
0+00)
0+00=E D CURB
0.25 CFS (10-YR STORM RUNOFF) FROM CONSTRII CTION TO
MATCHgX. GRADE /!Zl z 00
ROADWAY TO DRAIN ACROSS EXISTING _A11 0
WITH N SE -DOWN (0
GRAVEL SHOULDER INTO ROADSIDE DITC 28
79tXX C RB
DO
79 06
EX
CID
co I
4� OD
MAINTENANCE PLAN
SCALE: 1"=10'
2016 ROAD & BRIDGE STANDARDS
EDGE OF EAISING PAVEMENT
(AS DETERMINED 1N FIELD)
CONSTRUCT ON JOINT EXISTING ASPHALT LAYERS ROPOSED ASPHALT LAYERS
- - - - - - - - - - - - -
EXISTING SUBBASE PROPOSED SUBBASE
-------------------- T
COMPACNED SUBGRADE
CONSTRUCTION JOINT DETAIL
REMOVE EXISTING ASPHALT LAYERS TO EXISTING SU1313ASE AND REPLACE WITH PROPOSED ASPHALT WIDEMING LAYERS
PROPOSED MINIMUM 1 V, RICH THICK ASPHALT SURFACE COURSE (SEE NOTE 5)
A MINIMUM 12 INCHES, OR GREATER AS NECESSARY TO ABUT THE FULL THICKNESS or EXISTING ASPHALT LAYERS
AS DETERMINED 13Y CORES (SEE NOTE 3)
NOTES:
I ASPHALT PAVEMENT WIDENING SHALL HAVE A PAVEMENT DESIGN IN ACCORDANCE WITH CURRENT VDOT PROCEDURES AND BE APPROVED BY THE ENGINFFP
2. THE PAVEMENT DESIGN FOR ASPHALT PAVEMENT WIDENING SHALL MEET OR EXCEED THE DEPIHS AND TYPES OF IRE LAYERS OF EXISTING PAVEMENT
SUBSURFACE DRAINAGE OF THE EXISTING AND PROPOSED PAVEMENT SHALL BE ADDRESSED IN THE PAVEMENT DESIGN,
3 A MINIMUM OF THREE CORES SHALL BE TAXEN ALONG THE CENTER Or THE ADJACENT TRAVEL LANE TO DETERMINE THE TYPE AND THICKNESS OF EXISTING
PAVEMENT LAYERS. THESE CORES SHALL BE SPACED NO MORE THAN 500 FEET APART.
4. THE ADJACENT TRAVEL LANE SHALL BE MILLED A MINIMUM DEPTH or iv, INCHES AND REPLACED WITH AN ASPHALT SURFACE COURSE TO MATCH THE
PROPOSED PAVEMENT WIDENING SURFACE COURSE, UNLESS WNYED BY THE ENGINEER.
5- THE ENGINEER MAY REQUIRE THE MILLING DEPTH OF THE EXISTING PAVEMENT TO BE 413JUSTED TO ACHIEVE A14 ACCEPTABLE PAVEMENT CROSS -SLOPE
AM EFFECTIVE SURFACE DRAINAGE,
5. EXISTING PAVEMENT MARKINGS AND MARKERS WIIHN 1HE PROJECT LEMIIS SHALL BE RESTORED SU13JECI 10 THE APPROVAL OF THE ENGINEER.
7- FINAL TRANSVERSE PAVEMENT TIE-IN SHALL CONFORM TO THE REOUREMENTS OF SECTION 315 OF THE SPECIFICATIONS EXCEPT THAT ALL JOINTS
AT TIE-IN LOCATIONS SHALL BE TESTED USING A 10 FOOT STRAIGHTEDGE IN ACCGRDANCE WITH THE REQUIREMENTS OF SECTION 3t5 OF THE
SPECIFICATIONS.
XV013T SPECIHCA11ON
ROAD AND BRIDGE STANDARDS ASPHALT PAVEMENT WIDENING REFERENCE
SHEET I OF I I REVISION DATE FOR WIDENING SUBJECT TO TRAFFIC 315
VIRGINIA DEPARTMENT OF TRANSPORTATION
303.02
2016 ROAD & BRIDGE STANDARDS
VDOT STD. WP-2 DETAIL
PROP. GRADE
SEED AND STRAW ALL
DISTURBED GRASS AREAS
ONCE AT FINAL GRADE
:0 '�4
00
......
ROM
SEE NOTE 4 F
VIDOT STD. WP-2
PROPOSED ASPHALT
LAYER
PROPOSED
SUBBASE
DB 5266 PC 733
LIMITS OF DISTURBANCE ±1,500-SF
(TOTAL LEFT AND RIGHT)
0
0.25 CFS (1 O-YR STORM RUNOFF) FROM
ROADWAY TO DRAIN ACROSS EXISTING
GRAVEL SHOULDER INTO ROADSIDE DITCH.
NEW CURB (VDOT STD.
CG-2)
1.01 1.01
PROP.
SAW CUT
LINE
0 10 20
SCALE: 1"=10'
MIN. 1-1/2" THICK
ASPHALT SURFACE
COURSE
EXISTING
EXISTING GRADE
ASPHALTLAYERS
EXISTING
SUBBASE
COMPACTED SUBGRADE
NOTE: CONSTRUCTION TO ADHERE TO VIDOT STD. WP-2 EXCEPT AS MODIFIED
HEREON TO LIMIT MILL AND OVERLAY TO 2'FROM FACE OF NEW CURB AS SHOWN.
I
TYPICAL SECTION A -A
N.T.S
EMSCALE
E N G IN E E R I N G
applicant:
RAGGED MOUNTAIN FARM FICA
engineer:
30 SCALE, LLC
871 JUSTIN DRIVE
PALMYRA, VA 22963
p: 434.242.2866
e: mike@30scale.com
web: www.30scale.com
ui
>
z
<
0
_j
m
(0
zLIJ
00
LU
z
<
Of
LLI
Z
<
F---
CO
Z
LLI
I.
T_
I-_
0
z
00
w
LLI
0
UJ
z
<
LU
[)�
I ---
<
U)
(D
z
w
ry
z
>
z
0
L)
Ui
_j
m
<
LU
<
�2
m
U)
0
__1
LU
F_
w
w
_j
_j
LU
sheet title:
MAINTENANCE
PLAN
scale:
1 =10'
date:
06/30/2022
sheet#
20F2