Loading...
HomeMy WebLinkAboutSP202200003 Plan - Submittal (First) 2022-07-18Any datandand Mn of bpopephy or conlaurs. or any dapieon of"acal Impmvamems, prapeny litres or Eountlares rebgenval information only arin apall mid» eared for I di medricalun, m mnstngon of mmande is breal Property «tor Moor pain determination. Jury lz 2022 Map elements may reme lager than GIB data measured in IM map or es provided an Ore data downbad page due to the baaMlon used. Map Propcldn. WG884 Web Mori (Amf Sphere) (EPBG I857f My depmnnafwn a anabomphy nr wnroun.«an, aeare" rptiyslcal lmpmv¢manls, protocol, bnae or eounCwbs SM germs, lnmmason only aM areal mr be used as ma desgn. moElficalm, or constr iron or lmpmveman6 to rear orcpMy« for need Main malermormem, May lz. zozz Map elements may scale larger than GIS data measined n the map or as provNad on Me Balaawnloed pegedua to In. pmietlmn used. Map Pm,enrom. WG O,t wen Marcnmr (auamary spnare) lEnG]en) SP202200003 Dayfily Preschool 4330' Legend N.I. some gems on map may not appear legenm 57-4 4294" Parcel Into -- ❑ Parcels 57-23 57-24A y 4348,. 57-24 Q A M N 57-60 Is Dr 57-29D3 57-29D4 1547° 57-29A 4283 'J 42811 --J 57-30F 57-25 57-30B 57-59 57-60A 57-30E / V VV %� o c,�rapn�c oala xmce, www.alM1emaee orgl9n \ (01!)296 -50]2 )296 Any MlermmalFln pl lopo9rapl,y m contours, o any pepcpon of phyYral imp cedoenl5. properly lines of ScuMNres is for prepare! Oppr elron only per shall rot l» user for IM de9gu. modNcalwn of rvnSlwcron of iinde emenls to real posed, or for flood plain deldre aeon. May 12 2@2 We elements n ay scale larger Irian GIS data —sphere the map or as pmmded on the data eownfo d page due Ir the proleceou used Map Wmeclmn WG59a Wee Merralor 1Aml6ary Sphere) (EPSG 3657) y1 1 r i v tie IT v i �• r , d t �. 1 r> t. j z ty a I i � 1. t r 1 6/15/2022 Capacity Assessment �e �ec"� Onsite Wastewater System i �v F o� ae 's GAP 0�6 Mountain Plain Baptist Church �,� P Moving Preschool from Church to Rectory A?oFpsSloN".� Physical Address: 4297 Old Three Notched Road Charlottesville, VA 22901 ATTN: VDH — Albemarle County Assessment conducted by Old Dominion Engineering (ODE) Facility Usage The church is located on TM 57-26 (2.34 acres) and the rectory is located on the adjacent parcel TM 57-29A (1.69 acres). The existing preschool has been conducted in the church. They are moving the preschool to the rectory building. Minor improvements to the rectory building were done, however no building permit was required. The existing septic system for the rectory is quite old (installed in 1966). The septic system consists of a 1000 gallon septic tank and 800 square feet of drainfield (4 trenches, 2' wide, 100' long, approximately 24" deep). The septic system was for a 3 bedroom house. The rectory water supply is from the church well (no records on file). The new usage of the facility is for a preschool (Daylily Preschool). The preschool usage projections are: • 30 - 50 kids o Starting at 30 kids and would like to grow to 50 kids 3 - 4 staff This capacity assessment was done to determine if the rectory onsite wastewater and treatment system can handle the new usage of a preschool. Current Onsite Wastewater System Condition 1. Drainfield - No surfacing was found in the dispersal area during the inspection on 6/8/22. 2. Septic Tank - Inspection of visual components were satisfactory. 3. The cleanout is 4" SCH 40 PVC. It appears as if the sewer pipe has been replaced with modern materials. Page I of 3 Old Dominion Engineering —366 South Linden Avenue - Waynesboro, VA 22980-olddomeng@melos.net Estimated Water Usage and Wastewater Strength The wastewater characterization is based upon the following information. The peak septic usage is calculated at full capacity: • Preschool Children - 50 • Preschool Staff - 4 Water Use a and Wastewater Strength Unit Bates and Basis - Da li Preschool er BOD/TSS 3 wale, usage E9lmale Bass strength BoolTSS strength Bass gChildren tl (.or') Water usage mommnrp o1 slmiiar 20anes forth saedy �pteo' Per lrvnc 5E10670 BCD Foray comernal to USEPA Grain Waslewater Treatment systems Manual Table 3- 30o conceMration- (range517 Sandal ultroul stwwere a. vnIn or wthout ornard. gpolsluhong Par USEPA onslte Wevlewaler Treatment Systems Manuel 240 Per 12VAC 541 oan) Boo FlDrne ay cored to Ta01e 34 Office Emproyee 7l6 g�ompdyae eardamsoferad ones Buidi, Empbyee Water s1 Wy had Hunters Way PmscM1wl and Hoopes School WIM1 of wM1ich are kneader Ahemarle County. Hunlors Way Pmemdol wetl an aleragn of 3.4 guardroom and paganls School used an merage of 47 Wd. Both sludne were 3 months. Tna demognaphrc5 of Hunter Way Prescleol was 36 cMdmn and loachemt ape groups 7 montlm3 yoam and 6 6 years. 5 days per work. 11 hours per day. The r emop2ph¢5 of Regents &.1 was W Students and leaders; N91, gentle, brical odad year August to June. Facto, of Save, e[ceetls 1,811.3. 6 gwour n is consis lent with USEPA Cot Wastevaler Treatment Systems Manual Table 3.5 Day proms. without cafeteria, gym, or sM1owam 5-17 gpaparson. Peak Water Usage and Wastewater Strength Estimate - Daylily Preschool e, ed o m semin C 0 se Water Usage Activity Ts C m Aor 9 m 3 rn E E o di E V V 7 0 W m Preschool Children 50 6 300 300 0.7 Preschool Staff 4 10 40 240 0.1 Total 340 292 0.8 The wastewater effluent strength will not exceed residential strength for BOD or TSS. The wastewater strength is estimated at 292 mg/l BOD/TSS. Water usage is estimated at 340 gpd. Page 2 of 3 Old Dominion Engineering — 366 South Linden Avenue - Waynesboro, VA 22980 - olddomeng@ntelos.net 6/15/2022 Current Onsite Wastewater System Capacity 1000 gallon septic tank capacity @ 2 day detention time V 1000gal _ Q 6 2days = 500gpd Estimated peak flow of 340 gpd < 500 gpd - OK Drainfield Capacity per Day at Septic Tank Effluent Drannfield Capacity of Original VDH permit is 450 gpd Design HLR = .56 GPD/SQFT Originally Sized for a 3 BDR Home Corresponds to a current perc rate of 30-35 mpi Proposed Hydraulic Loading = 340 gpd Proposed HLR = .425 GPD/SQFT Corresponds to a current perc rate of 45-50 mpi Adequate area is available on the property for a repair drainfield Conclusions The existing septic system is adequate for the new usage of a preschool. The well permitting will be required to be upgraded from a private well to a non -tom ciPnt non -community well. The owners have contacted VDH-ODW and begun the process of converting the water system permit. Recommendations The drainfield is quite old. Due to the age of the drainfield ODE makes the following recommendations: It would be prudent for the Church to financially plan for an eventual drainfield replacement. The preschool and church should monitor the performance of the drainfield (i.e. observe any soggy spots developing during mowing would be adequate). Monitor the water usage at the rectory on a monthly basis and determine the daily water usage for preschool usage days (total water used during the month divided by the total number of days the preschool was open). Verify that the daily water usage is less than the estimated amount (340 gpd). Avoid growing the preschool too large. The more kids at the school, the more water used and delivered to the septic system. The less water put in the septic system, the longer the drainfield will last. Page 3 of 3 Old Dominion Engineering — 366 South Linden Avenue - Waynesboro. VA 22980 - olddomeng9ntelos.net 7/12/22, 2:19 PM Yahoo Mail - Daylilly Preschool: Found NTNC Waterworks Daylilly Preschool: Found NTNC Waterworks From: Valencia, Taylor(taylor.valencia@vdh.virginia.gov) To: Ifclama n@yahoo.com Date: Tuesday, July 12, 2022 at 01:37 PM EDT Good Afternoon Elizabeth, Our office is moving forward with "grandfathering" the Daylilly Preschool facility as a nontransient noncommunity (NTNC) waterworks system to be regulated by our office. A public waterworks system identification number has been created for your waterworks system (PWSID 2003525). Over the next few weeks, I'll help you through the permitting process and all required submittals to our office in order for us to issue you a formal standard waterworks operation permit. The closer we get to issuing you a standard waterworks operation permit, we will contact you to schedule a formal inspection (also called a sanitary survey) of the system. Our in -person meeting on July 8th served as an "initial visit" but not a formal inspection. Your facility should be permitted by the end of this year. However, we will require sampling requirements to commence once the facility is serving 25 or more people. Sometimes, the paperwork side of things can take longer than expected but the sampling requirements begin as soon as the system is classified as a public system that is serving 25 or more people for 60 or more days out of the year. Please let me know if you have any questions! Taylor L. Valencia District Engineer Virginia Department of Health Office of Drinking Water - Lexington, VA Phone: (540) 463-0421 about:blank 1/1 0.1" %Y . i SP202200003 Daylily Preschool -A-f—j - _ IIx fox dw, .Ilk N�X�S=B' iC iZ, t 7 L"Loo1Z PL4A/ • u I i SP202200003 Daylily Preschool 6�ou�r1'cdvt.l - i3'xr3' • j a� I1 ZZ' X 2.l ' SP202200003 Daylily Preschool If 141 Closet I l'K 1!: P Rd 2610, K Sv 4-S yemr old yawn 0 0 0 SP202200003 Daylily Preschool '% i %I w i 1 O to It I'eu IV m rrWwra 'De%"Tfwh� S ^C& 2.Zx 2.71'