HomeMy WebLinkAboutCLE202200094 Other 2022-07-180 0 0 I tn O I 6 eo 15'-7' 1 1 15'-7' CONSTRUCTION NOTES 1. WORK SHALL CONFORM TO ALL APPLICABLE CODES AND ORDINANCES. 2. DO NOT SCALE THE DRAWINGS. 3. CALL ANY AND ALL DISCREPANCIES OR OMISSIONS IN DIMENSIONS TO THE ATTENTION OF THE OWNER AND ARCHITECT PRIOR TO COMMENCING WORK. 4. NOMINAL DIMENSIONS SHOWN. WALLS TO ALIGN W/ WINDOW OPENINGS WHERE OCCURS. 5. INTERIOR PARTITIONS TO BE AS SCHEDULED, SLAB TO UNDERSIDE OF FLOOR JOISTS, TYPICAL. CAULK BOTH SIDES OF BOTTOM PLATE. PROVIDE 5/8' DRYWALL ON "SOUNDBOARD" 0 LOCATIONS SPECIFIED BY OWNER, INCLUDING BATHROOMS. DRYWALL TO EXTEND FROM SUBFLOOR TO UNDERSIDE OF FLOOR JOISTS IN ALL CASES. 6. ALL SCW CORRIDOR DOORS TO HAVE 20 MINUTE UL RATING. 7. PROVIDE WATER & SANITARY LINES TO EXAM ROOMS AS DETERMINED BY TENANT. DRAWING SHOWS SCHEMATIC LOCATION OF SANITARY LINE. NOT ALL LOCATIONS SHOWN. m 202'-0' 0 It FIRECODE DRYWALL AT SIDE OF FLOOR JOISTS. 20 PLATE TO UNDERSIDE OF FLOOR JOISTS. ACOUSTIC TILE CEILING, TIP.) 1/2" DRYWALL, EACH SIDE. 2x4 BLOCKING. 2x4 STUDS 016" WOOD OR VINYL BASE. PLATE, CAULKED BOTH SIDES. ,&. 0'-0" TOP OF SUBFLOOR 0 WALL TYPES 2 1 /2' = V-011 rn 2 LAYERS 5/8' FIRECODE DRYWALL AT UNDERSIDE OF FLOOR JOISTSON CORRIDOR SIDE OF WALL 0 20 PLATE TO UNDERSIDE OF FLOOR JOISTS. ACOUSTIC TILE CEILING, TYP.) 5/8" FIRECODE DRYWALL, EACH SIDE 2x4 BLOCKING. 2x4 STUDS 016'. WOOD OR VINYL BASE. 2x4 PLATE, CAULKED BOTH SIDES. &, 0'-0" TOP OF SUBFLOOR rn 0 a 5/8" FIRECODE DRYWALL AT UNDERSIDE OF FLOOR JOISTS. O 2x6 PLATE TO UNDERSIDE OF FLOOR JOISTS. ACOUSTIC TILE CEILING, TYP.) CENTER DEMISING PERTITION AROUND EXIST. 5" STL. TUBES. (2) LAYERS 5/8- FIRECODE DRYWALL, EACH SIDE 0 SIM. 5/8" FIRECODE DRYWALL, EACH SIDE. 2x6 BLOCKING. 2x4 STUDS 016". WOOD OR VINYL BASE. 2x6 PLATE, CAULKED BOTH SIDES. &, 0'-0" TOP OF SUBFLOOR 12'-0" 12'-0' 15'-7' 15'-7" 12'-0' 12'-0' 15'-7' 15'-7' .9 H 5/8- FIRECODE DRYWALL AT `UNDERSIDE OF FLOOR JOISTS. / 2x4 PLATE TO UNDERSIDE OF GRID. COUSTIC TILE CEILING, TYP.) o ------ ------ of io ------ ------ oI io ------ ------ oI PROVIDE WATER & SAN. LINES IN EXA I I "PAYMENT' 14� WINDOW I I 142 14] I ROOMS. NOT ALL LOCATIONS SHOW SEE NOTES RECEPTION T.B.D. RECEPTION a M RECEPTION a RECEPIION a I RECEPTION a RECEPTION I WINDOW T.B.D. SPRINKLER z SANITARY ROOM LINE T.B.D.. z z 15 -7 "8 SANITARY J LINE T.B.D. � C C LHWH ON.. 3(i r4 I I r HWH oN S I oI I I I z. I I I z sHLF. Aev I�I L HI z PROVIDE WATER & z ®� I z I — - \ SAN. LINES IN ELEC. EXAM ROOMS AS _ _ & DATA SHOWN i i _ _ 30 z48 - / _ _ / & DATA N SCHEMATICALLY. I I i L... I I I �/ I T.B.D. BY TENANT. �_. " L ^ L' / I I^ 2 -6" T-6" ' 4'�O. 10'- " ' I z z '-7" T-6" ' I4'-0' 9'-11' , I L I z I z , I 10'-9" ' 3'-10" 2 .. 4 ... Z' .. r Z... r ...2 ... Z ...2 ... 2.. 2 Z 3 2 a 2 O a 2 a 2 i a 2 2 01 a' I I I I I I 77=4 <....L... 4f. .. '` I l o CONFERENCE - -- - - - --- --- --- - -- CONFERENCE 9'-10" T68' I 9'-1 ' 6'-8" I 25'-2" in LOWER LEVEL PLAN 1 /S" = V-0" 0 O 0 1/2" DRYWALL, EACH SIDE. 20 BLOCKING. 2x4 STUDS 016". WOOD OR VINYL BASE 0'-0. TOP OF SUBFLOOR NOTES Q REMOVE EXIST. WINDOW & SALVAGE FOR RE -USE. PROVIDE NEW 36"x8O" METAL DOOR W/ LOCKSET & EXTERNAL LOCK BOX FOR F.D. USE. PROVIDE SIGNAGE PER CODE. PROVIDE OBSCURE FILM TREATMENT ON INSIDE OF WINDOWS SHEDULED TO REMAIN. SEE SPRINKLER ROOM SHOP DRAWINGS FOR MORE INFO. PLTH pF DAVID KARIEL v Lic.No.:8165 F 04-10-20 �w ti 04-10-20 SPRINKLER ROOM h LA N M P U II 11 o N 1 N 7 ti O Ji U +! o N' x z A o 0 r� V �I I� n rn WOO O O � O � � Irr�ll V DATE: 04-10-20 SCALE: AS NOTE DRAWN: JSF CHECKED:DK JOB NO. 2007 Ami