HomeMy WebLinkAboutARB202200058 Correspondence 2022-07-21Verizon Wireless — Scruby Property - Tier III
Personal Wireless Service Facility
Project Description / Request:
Cellco Partnership, operating as Verizon Wireless ("Verizon"), respectfully requests approval of
a Special Use Permit and Special Exemption for a Personal Wireless Service Facility (PWSF),
including a 140-foot tall monopole to be located immediately south of the nearest addressed
parcel at 7418 Greenwood Station Road, and identified as Tax Map & Parcel Number 05500-00-
00-01400 (the "Property"). The leased area is 40'x40'. Verizon's proposed radio transmitter
cabinet will be placed on a concrete pad, besides an approximately 10' wide utility H-Frame
stand and power communication components on a steel grated platform, and an emergency back-
up power generator on another concrete pad. This facility will be installed within a 400 square -
foot fenced compound and the ground equipment will be covered with an ice guard to prevent
possible damage to the ground equipment due to falling tree branches and ice. The monopole,
antennas, and base station equipment that might be visible above the screening fence will all be
painted with Sherwin Williams Java Brown - #6090, which is a matte enamel color that has been
previously approved as an appropriate color for many other "Treetop" Personal Wireless Service
Facility sites throughout Albemarle County.
Network Objectives:
Verizon is licensed by the Federal Communications Commission (FCC) to provide state-of-the-
art wireless telecommunications services within Albemarle County using a combination of four
(4) separate bands on the frequency spectrum. These consists of the 850 MHz band for Cellular
(CDMA), the 1900 MHz frequency band for Personal Communications Services (PCS), the 4G
Long Tenn Evolution (LTE) on 700 MHz band, and Advance Wireless Services (AWS) on the
2100 MHz band. In addition, the site will be upgradable to 5G CBAND service with just a small
equipment change at the time of the tower installation. The network offers data upload and
download transmission speeds that much faster than the previous generations of wireless
technologies. Verizon has also recently added high -definition calling capabilities to the data
networks in the form of Voice Over LTE (VOLTE) service.
Whenever possible, it is Verizon's goal to provide seamless in -building, in -car, and on -street
coverage and the full range of voice and data services to existing and future customers. Verizon
has determined that the area surrounding this proposed site needs expanded coverage to better
service the nearby residences, businesses, and traffic along the I-64 Interstate. Therefore, this site
is intended to provide infill coverage while also adding additional network capacity by
offloading traffic from the company's nearest existing sites in all directions. Although the
proposed 140' monopole tower would be too short to maximize coverage, it should allow the
antennas to clear the highest treetops within the immediate area on this parcel allowing service
from this facility to connect the with customers who are currently drawing on the marginal
coverage levels that are currently being provided by the four (4) nearest neighboring sites: " I64
West' to the west (VZW PWSF off Newton Heights Road), "Yancey Mills" to the East (VZW
PWSF off Patterson Mill Lane), "Parsons Green'to the southwest (VZW PWSF off of Route
151— Critzers Shop Road), and "Railroad Avenue" to the Northeast (VZW Rooftop Mounted
Antenna in Downtown Crozet).
Character of the Area:
The proposed PWSF will be contained within a 1600 square -foot lease area located on a 44.73
acre property used for agricultural & residential purposes. The site of the proposed facility has a
Scruby Property—Verizon Wireless Tier III PWSF
Verizon Wireless — Scruby Property - Tier III
Personal Wireless Service Facility
ground level elevation of 740.8 feet Above Mean Sea Level (AMSL). The subject parcel, which
is in the White Hall Magisterial District, is located off of Greenwood Station Road, is zoned
Rural Areas (RA), and is located within the Entrance Corridor (EC) Overlay District and the
Greenwood -Afton Rural Historic District (DHR ID 40088-5075). All adjoining properties are
zoned Rural Areas (RA) and have a mix of residential and agricultural uses. Access to the
proposed PWSF will be provided from the east side of Greenwood Station Road, utilizing an
existing gravel entrance to the property. The proposed monopole will be located approximately
754'2" feet east of the nearest boundary line with the right-of-way for Greenwood Station Road
and 32' 10" from the boundary line with the right-of-way for I-64. The nearest off -site dwelling
is located approximately 1300' northwest of the monopole site across I-64 on property identified
as Tax Map / Parcel Number 05400-00-00-07100.
Compliance with Section 5.1.40 of the Albemarle County Zoning Ordinance Section 5.1.40(b) —
Development Requirements for Tier III Personal Wireless Service Facilities (Items 1-12):
1. General Design: The Facility shall be designed, installed, and maintained as follows:
(a) Guy Wires: The proposed monopole will not require any installation of guy wires.
(b) Outdoor Lighting: One LED Floodlight will be placed on the utility H-Frame and test
lights will only be used as needed during unexpected events that require nighttime
visits by Verizon's technical operations staff. The proposed light must be adjustable
to illuminate various parts of the compound for safety reasons. However, it will not
be turned on nightly and will be located well below the treetops which will provide
natural shielding from the light shining skyward during any relatively short periods
of emergency maintenance.
(c) Ground Equipment: Proposed equipment consisting of the base station cabinets, H-
Frame stand and generator will be placed in a location that is screened from offsite
views by the surrounding trees, and a wooden fence will also be installed to help
fortify the existing screening elements that are offered to this site. Any portions of
equipment that are visible above the screening fence will be painted to match the
tower and blend into the wooded area.
(d) Whip Antenna: No whip antennas are currently proposed with this application.
(e) Grounding Rod: The proposed grounding rod to be mounted at the top of this
monopole will comply with the County's sizing requirements for a maximum of Two
(2) feet in length and one (1) inch in diameter.
2. Antennas and associated equipment:
(a) Number of arrays: Verizon will use a mounting collar and mounting frames that will
allow all six (6) of the necessary antennas to be installed in a single array within
three (3) horizontally separated sectors at the same height. This antenna array will
be centerline mounted at the 136 foot,4GL level (876.8' AMSL), with the (2) antennas
grouped in each sector to support the combination of the licensed Cellular, PCS,
LTE, and,4WSfrequencies all at one mounting level on the monopole. Other
supporting devices that consist of six (6) remote radio heads and two (2) fiber optic
surge protection boxes will be placed below the antenna array on an additional
array.
Scruby Property—Verizon Wireless Tier III PWSF
Verizon Wireless — Scruby Property - Tier III
Personal Wireless Service Facility
(b) Size: The antennas initially to be installed in Verizon's array are identified as
Commscope Model Number: NHH-65C-R2B [96.0 "(H) x 11.9 "(W) x 7.1 " (D),
equaling 1,142.40 square inches]. Specific equipment will likely change over the life
of the PWSF as technology advances.
(c) Projection: The antennas are proposed to be mounted with 18" between the face of
the monopole and the backs of the antennas, and no need for physical down -tilting.
Therefore, Verizon is also requesting approval of a Special Exception to modify
Section 5.1.40. b(2) (c) of the Zoning Ordinance which allows maximum distances of
12" to 18" between the face of the monopole and the back of the antennas when
down -tilting is employed.
(d) Color: A11 antennas will be painted the same Java Brown color as the proposed
monopole.
3. Tree Conservation P1an;Content:
Prior to the approval of a building permit, Verizon will also provide a tree conservation
plan that has been prepared by a Certified Arborist. As standard practice, the designated
arborist will not issue a written conservation plan letter until after they have had the
chance to review Verizon's Final Construction Drawings I Site Plan and visit the site.
The final issued letters often provide recommendations for any post -construction tree
care techniques in addition to granting approval for app proposed land disturbance
techniques, vegetation protection fencing locations, and other design elements that might
affect the health of trees that surround this site. No tree removal is planned with this
project.
4. Creation of slopes steeper than 2:1.
Upon the completion of this project, none of the remaining slopes will be greater than 2:1
as a result of construction and land disturbing activities for the proposed facility.
5. Ground equipment shelter -,fencing.
Verizon is proposing the installation of a 10 foot (10 ) tall wood fence in order to prevent
trespassing. The location and design details of the proposed screening fence are
provided in the construction drawings/site plan being submitted with this application.
6. Screening and siting to minimize visibility.
The monopole will be located 754' 2 "from the right-of-way line for Greenwood Station
Road (Route 690) and 32' 10" from the I-64Interstate right-of-way. There are
numerous mature trees along the north property line that will screen views of the
monopole from adjacent properties and the I-64 corridor. No tree removal is planned
with this project.
7. Open space plan resources.
The PWSF is located along the I-64 interstate right-of-way but the numerous mature
trees located along the right-of-way will screen the view of the monopole's location. In
addition, the PWSF is also located within the Greenwood Afton Rural Historic District
(DHR ID #0088-5075) which covers an area of approximately 16,300 acres. The PWSF
Scruby Property—Verizon Wireless Tier III PWSF
Verizon Wireless — Scruby Property - Tier III
Personal Wireless Service Facility
location was chosen due to its location close to the I-64 interstate and the ability by
VZW to locate the structure on an agricultural lot to minimize any impact to historical
structures or uses.
8. Horizontal separation of multiple facilities.
This facility will be the first facility on the property and therefore this provision is
inapplicable.
9. Diameter of monopole
As indicated in the attached construction drawings, Verizon's proposed monopole will be
designed and constructed so that it is 30 inches at its base and tapers to 18 inches at its
top.
10. Height of Monopole
140' foot tall (880.8 feet Above Mean Sea Level — AMSL).
11. Color of monopole, antennas, and equipment.
The monopole and all antennas will be painted Sherwin Williams Java Brown #6090, a
color that has been applied to a number of treetop PWSF monopoles in Albemarle
County. All of the base station equipment that is installed to support this facility will also
be painted the same color and enclosed behind a ten foot (10 ) wooden security fence.
12. Placement of cables, wires, and similar attachments.
The proposed monopole will be designed and constructed to contain all of Verizon
Wireless's coaxial and fiber optic cables that will run from the ground equipment to all
antennas and their supporting devices.
Section 5.1.40(c) — Applicability of other regulations in this chapter (Items 1-6):
1. Building site exemption.
Verizon acknowledges this exemption from the standard building site requirements for
PWSF.
2. Vehicular access.
Verizon will utilize Greenwood Station Road and the existing gravel access off of the
public right-of-way to access the property.
3. Setbacks.
Verizon has selected a location for this proposed monopole facility will be located
754'2 " feet from the right-of-way line for Greenwood Station Road (Route 690) and
32.10 `from the I-64Interstate right-of-way. The PWSF is located 185 `from the adjacent
property line shared with Parcel ID #05500-00-00-01500.
4. Area, bulk, and minimum yards.
Verizon acknowledges this exemption that allows relief to PWSF from the standard area,
bulb and minimum yard requirements.
Scruby Property—Verizon Wireless Tier III PWSF
Verizon Wireless — Scruby Property - Tier III
Personal Wireless Service Facility
5. Required yards.
Verizon acknowledges this exemption that allows relief to PWSF from the required yard
standards.
6. Site plan.
Please refer to the attached construction drawings with site plan details and the
specification sheets for proposed antennas and equipment that all demonstrate
compliance with the Tier III PWSF criteria, set forth in Section 5.1.40(a) (4) — Plans and
Supporting Documents. Any other supporting information that is deemed relevant to the
requirements set forth in Section 32 of the zoning ordinance for site plans can be
submitted upon request.
33.40(B) — Factors to be Considered for Special Use Permits
In acting on a special use permit, the Board shall consider the following factors, provided that the
Board is not required to make specific findings in support of its actions.
1. No substantial detriment:
This proposal meets all the design criteria for a Tier III PWSF currently required by
Section 5.1.40 of the Albemarle County Zoning Ordinance. The property is screened by a
buffer of mature trees that will help to screen the facility from adjacent properties and
the I-64 interstate. The PWSF is unmanned (no water and sewer) and only requires
monthly trips by a technician to maintain the facility, therefore impacts to public facilities
and infrastructure will be minimal. The property does not contain steep slopes or
floodplains nor will the proposed development create any steep slopes greater than 2:1.
Lastly, the PWSF will not require any lighting on the structure or emit noise or odors
which would affect any adjacent property owner's quiet enjoyment of their property.
2. Character of the nearby area is unchanged:
The area surrounding this facility is a mix of rural residential with large parcels being
used for agricultural purposes. No trees are scheduled to be removed for the installation
of the facility.
3. Hannony:
The RA (Rural Area) district was established to preserve agricultural and forestall land
activities, water supply protection and conservation of natural, scenic, and historic
resources. There are adjacent conservation easements located on Tax Map (`TAP') 55-
15 & 71-2B (Seven Oaks Farm — ALB-00860), TAP 54-74E (Mirador Farm — ALB-
00933), TAP 70-15E (PRF20140002), TAP 70-15D (PRF20140001), TAP 55-13A &
TAP55-12E & TMP 55-12 (ALB-02266), TMP 55-21 & TMP 55-81 & TMP 55-80 (ALB-
0822), TMP 55-12B & TMP 55-20A & TMP 55-20 & TMP 55-16B (ALB-01370), and
TMP 54-74F & TMP 54-20 & TMP 70-4 (ALB-00741). These easements seek to protect
the open and scenic views, as well as visibilityfrom neighboring properties also currently
under conservation easements. A mature tree buffer on the associated property along
Scruby Property—Verizon Wireless Tier III PWSF
Verizon Wireless — Scruby Property - Tier III
Personal Wireless Service Facility
with those on neighboring properties will adequately screen the facility from adjacent
properties and those traveling within the Historic District. The Applicant advised Justin
Altice of the Virginia Outdoors Foundation (VOF) about the details of the project, and
Mr. Altice provided the Applicant and the County staff with the six (6) VOF deeds for the
easements in the area. Though the Applicant invited VOF to the balloon test, VOF
responded that review is conducted by County staff, and VOF would not be reviewing the
proposed facility. Two easements are held by the County in the ACE program.
4. Consistency with the Comprehensive Plan:
Per the adopted Albemarle County 2015 Comprehensive Plan calls for the preservation
of the county's historic, archeological, and cultural resources within the Rural Areas.
After multiple meetings with adjacent property owners, Verizon has moved the proposed
location to limit the effect on the historic, archeological, and cultural resources in the
area. There is a mature tree buffer along all the property lines which will screen the
PWSF from adjacent properties. The proposed PWSF and ground based equipment will
be painted brown which further will allow the facility to blend within the natural
environment.
Objective 10 of the Community Facilities Chapter 12 of the Comprehensive Plan is to
support the provision of private utilities, including wireless service when its provision is
in keeping with other aspects of the Comprehensive Plan. This proposed site supports
this objective and is consistent with Strategy IOe as the proposed facility has been sited
and designed in accordance with the County's Personal Wireless Service Facilities
Policy.
Conclusion
Approval of this PWSF application will contribute to the expansion of Verizon's coverage to the
Rural Areas, existing and future residents and businesses as well as travelers on the I-64
interstate. This facility will also help to reinforce network capacity and relieve some of the high
levels of traffic that has been experienced at the neighboring network locations. The monopole
tower serving this PWSF will meet the County's design preferences for monopoles that extend
just above the treetops with dark brown finishes and well -screened base station compounds.
Therefore, Verizon is confident that the proposed PWSF will meet the design criteria necessary
for approval of a Tier III Facility, and that is does not conflict with any of the goals and
objectives set forth in the Albemarle County Comprehensive Plan.
Sincerely,
Nathan Holland
GDN Sites
Site Development Consultants to Verizon
Scruby Property—Verizon Wireless Tier III PWSF
Verizon Wireless — Scruby Property - Tier 111
Personal Wireless Service Facility
Scruby Property— Verizon Wireless Tier 111 PWSF