HomeMy WebLinkAboutSUB201400215 Checklist Road Plan and Comps. 2014-12-19 Albemarle County Engineering Road Plan checklist for plan reviewers 2 Dec 2014 A road plan is a document detailing the design and construction of a road, street or alley. It is typically bonded in order to record subdivision plats. Reference key; [Square Brackets] are County Code references, {Curved Brackets} are policy references, and(regular parenthesis)are explanatory. Links to reference documents are provided where possible. Application information: Completed application and fees. Road plans require a Subdivision application.No review is provided without applications and fees. Plans containing both public and private roads should pay the higher fee for private roads. k(A Copies of federal and state permits for any wetland or stream disturbance. (Army Corps, VDEQ, etc) [18-32.1.2, 14-311] Title nformation: Project title. Titles should be appropriate. It should be a road or street plan, not a site plan, subdivision plan, or erosion control plan, etc. yrofessional seal,with original signature and date. [18-32.6.1] ✓ Content: The road plan must contain, for each road/street/alley, at a minimum 1. 1. a plan view, customarily at 1"=50' or better. a profile view _✓3. a typical cross-section Thefian should NOT contain vast areas of work outside the road section. Construction of a road should not be an excuse to mass grade, or install other utilities or improvements. General information: The owner should be prepared to bond the plan in its entirety. Legal bond agreements require that the plan be referenced to the bond agreement using the exact title of the plan document. The county is trying to avoid multiple bond agreements referring to a single plan. Therefore,phases to be bonded separately should be separated into stand-alone plan packages to accompany each bond. VDOT approval is obtained for any plan affecting public right-of-way. For public road plans, VDOT review will supercede most detailed design items below. Fire/Rescue Department approval is obtained separately from Community Development engineering review. Plan view: [18-32.6.2, 14-304, Subdivision Ordinance Article IV Division 2, VDOT SSAR] ✓ accurate current existing topography at the time of submittal, including all existing site features, and any recent disturbances, all at a legible scale date and source of the topographic information: All topography should be at least visually field verified by the designer within the last year (Aerial topography is often noticeably Albemarle County r.,igineering Road Plan Checklist Page 2 of 5 inaccurate. Disturbances sometimes take place subsequent to the flown date. This can be a particularly recurring problem where early or mass grading plans have occurred previously. In these cases,the topography needs to be updated.} ►� WPO buffer limits; 100' from stream or wetland bank, 200' from reservoirs, or floodplain limit if greater [17-600] floodplain limits, including 100yr flood limits for any channel with a drainage area of 50+acres [18-32.6.2d, 18-30.3] ,/ all existing easements (access, drainage, sight, sanitary easements, etc.)with deed book references, locations and dimensions. all existing streets included with labeled pavement and right-of-way widths, route numbers and street names V all proposed streets included, with right-of-way and street names V stationing at 50' minimum on all proposed streets, on plan and profile ✓ street horizontal curve start point, end points and radii labeled,meeting standards cul-de-sacs provided on all dead-end streets or alleys (see the Design Manual reference details) street edge of pavement or curb radii labeled at all intersections and turnarounds (see the Design Manual reference details) .,d4oundabouts designed per VDOT and ASHTO guidelines guardrail over any slope steeper than 3:1,wall, or drop-off greater than 4',with start and end sections labeled, and VDOT designations (GR-2, GR-2a, etc.) (see the VDOT Road Design Manual. Guardrail placement is complicated and subject to a lot of judgement and variation. This is a quick rule-of-thumb summary.) pJ A- pavement markings dimensioned and labeled ✓ signs for traffic control shown and labeled: speed limit on all streets, stop signs at all intersections street name signs at every intersection,typically placed opposite stop signs [should reference County Road Naming and Property Numbering Ordinance and Manual] OP( street tree locations, species and height or caliper (typically to be reviewed by Planning) Grading: ✓proposed topography at minimum 2' contour intervals—tied into existing contours, as well as all proposed site features. (Sites with less than 6' of grade change should consider ✓ using smaller contour intervals.) proposed slopes are all 2:1 (horizontal:vertical) or flatter {Design Manual, section 8} __ _proposed slopes steeper than 3:1 have low maintenance(not grass) ground cover specified on the plan {Design Manual, Section 8} ✓existing critical slopes are not disturbed,unless a waiver or exemption has been granted for the disturbance. pre- Retaining walls should be accurately shown on plans, reflecting material thickness and batter where such measurements may affect layout. �" Retaining Wall Plans checklist. Any walls supporting roads or necessary infrastructure require engineered plans (not generic manufacturer's details)and computations. {Design Manual, section 8} This will also be required where walls are close to property lines and there is the danger of affecting neighboring property, either during construction, with later failures, or with pedestrian or vehicle safety. These concerns can be alleviate with layout spacing also. In any case,retaining walls will require building permits at construction. Albemarle County zugineering Road Plan Checklist Page 3 of 5 Required Easements: [Zoning Ordinance 18-32.7.4, Subdivision Ordinance, Article IV, Div. 4] ✓ all proposed permanent easements, dimensioned and labeled Examples of easements are: ,111P'sidewalk easements for sidewalks to be maintained with streets outside right-of- way. It is preferable that sidewalk be inside street right-of-way. ✓ drainage easements for any drainage passing through the site from off-site, or for drainage crossing proposed property lines. ✓ stormwater management easements over all facilities and associated structures and access N� interparcel access easements � -intersection or entrance sight easements all drainage easements are a minimum 20' wide. Required width: 10'+(pipe dia. or channel width)+2'+2(depth-5'). The pipe, channel or structure must be within the center third of the easement. {Design Manual, section 6} ✓ no structures or trees within drainage easements {Design Manual, section 6} Entrances and right-of-way improvements: [per VDOT Secondary Street Acceptance Requirements (SSAR), and VDOT Road and Bridge Standards] V only approved entrances are shown. Placing entrances on road plans should not be a way of circumventing site plan review of entrance placement or number, or adequate review of traffic, spacing,turn lanes, etc. all entrances have a VDOT designation [PE-1, CG-9a, etc). In the case of dense residential development, concrete entrance aprons are important to continue drainage on the street side, and to control fine grading of asphalt and sidewalks. itik commercial entrances do not exceed 4% grade for a distance of 40' from the intersected street,measured anywhere in the entrance [18-4.12.17] unobstructed sight distance lines at entrances, less than 10' x Speed Limit of intersected streets, measured from a point 10' off the edge of pavement of the intersected street 25' minimum radii on entrances(or per VDOT requirements,typically 25'-35') [per ,VDOT Access Management Regulations and Standards] Af turn and taper lanes where applicable with lengths and widths labeled (taper at 12:1 with 12' lane widths) Profile View: (applicable only to road or street plans) ✓ stationing at 50' minimum on all proposed streets,to match the plan view sheets .7 proposed centerline ✓ existing ground centerline (Historically,the existing centerline was field surveyed,but this is happening much less with current aerial topography. This may be requested if inaccuracies are noted.) ✓ labeled existing and proposed grade at each 50ft station point ✓— vertical curves provided at all grade transitions ✓vertical curve start, vertex and end points labeled ✓vertical curve length and K(or stopping sight distance) labeled at each vertex,meeting required design values percent grades labeled for all road segments, meeting design values (VDOT Road Design Manual, App. B) . Albemarle County rAgineering Road Plan Checklist Page 4 of 5 ✓ rural street intersections continue the -2% intersected cross grade for a minimum of 20' from the edge of pavement of the intersected street. A low point is provided off the intersected street for drainage. {policy, following VDOT practice} ,/street grade is less than 4%for a minimum of 40' from the edge of pavement of the intersected street. (This grade can be within the first road curve which transitions from the 2% intersected cross grade) {policy, follows ord. for travelways 18-4.12} ✓pipe and utility crossings shown and labeled(ACSA has minimum clearances) V cross drain locations shown and labeled with VDOT designations(CD-1,2)at every major cut and fill transition or sag curve ✓ the station of intersections are shown and labeled with the street names ✓grades are a maximum of 6% in turnarounds —grades are a maximum of 4%through roundabouts Details and Sections: (reference VDOT Road Design Manual, or Sub. Ord.) -/ typical sections for each street, street segment, or alley Albemarle County general construction notes for streets (reference) t/traffic generation and distribution summary(ADT's) with road networks ✓pavement designs per VDOT guides [2009 VDOT Pavement Design Guide for Subdivision and Secondary Roads in Virginia] / pavement widths meeting design standards / pavement crown at '/a":1' slope l pavement surface,base, and sub-base thicknesses and materials /curb and gutter where applicable with VDOT designation(CG-6), and stone base of 6" 21-A or better(CG-2 also acceptable if a gutter is not needed for drainage) / shoulder at 1":1' slope or flatter and 4' or greater width for rural sections / maximum slopes of 2:1 or flatter with guardrail shown where applicable. proposed slopes steeper than 3:1 have low maintenance(not grass) ground cover specified on the plan Pit-guardrail guardrail over all fill slopes and culverts,with 3' additional shoulder,using VDOT designations(GR-2, GR-2A, etc.) / right-of-way/easement width, centered on street, meeting design standards WA- sidewalk location and widths, minimum 5' width, 4" concrete surface, 4"21-A stone base,with underdrains (UD-4, etc)per VDOT standards where applicable P,4-planting strip if applicable, 6' minimum width [14-422] ✓ ditches dimensioned at 3:1 slope from shoulder, 1' depth min., and 4' min. width from shoulder to ditch centerline, for rural sections Mt alleys have 12' pavement width, with 14' wide stone base [14-410] Al transitioning detail (20' minimum) for roll-top curbing in front of any inlets / typical sections for proposed channels with locations referenced from the plan view sheets Vk sidewalk detail or specification to be a minimum 4" stone base and 4"concrete of 3000psi at 28 days, or stronger. [VDOT App. B, Subdivision Street Design Guide, and 14-422] $JAr retaining wall details referenced from plan, if detailed plans and comps were not required. This is only really applicable to standard VDOT gravity walls. Walls not affecting the road should not appear on road plans. ✓ Rural section ditches may not be deep enough for 15"diameter culverts within the ditchline if the ditches are only 1' deep. This usually involves moving the ditchline away