Loading...
HomeMy WebLinkAboutWPO202000037 Plan - VSMP 2022-07-06GENERAL NOTES OWNERS: TMPogloo-oo-oo-oo9oo GALAXIE FARM INVESTMENTS, LLC 600 EAST WATER STREET, SUITE H CHARLOTTESVILLE, VA 22902 TMP ogioo-oo-oo-o25oo GALAXIE FARM INVESTMENTS, LLC 600 EAST WATER STREET, SUITE H CHARLOTTESVILLE, VA 22902 DEVELOPER: RNERBENDDEVELOPMENT, INC. 455 SECOND STREET SE, SUITE 400 CHARLOTTESVILLE, VA 22903 ENGINEER: COLLINS ENGINEERING Zoo GARRETT ST, SUITE K CHARLOTTESVILLE, VA 22902 TAX MAP: 09100-00-00-00900 D.B. 5445, PG. 5o 5.og ACRES 09200-00-00-02500 D.B. 5445, PG. 54 8.27 ACRES ZONING: PLANNED RESIDENTIAL DEVELOPMENT (PRD) WITH ENTRANCE CORRIDOR OVERLAY DISTRICT(EC) AND MANAGED & PRESERVED STEEP SLOPES OVERLAY DISTRICT PRD ZONING WAS APPROVED BY THE BOS ON DECEMBER 4TH, 2029. TOTAL PROJECT AREA: 09100-00-00-00900 - 5.09 AC. 09100-00-00-01500 - 8.27 AC. TOTAL = 23.36 AC PROPOSED USE: 65 TOTAL DWELLING UNITS (43)SlNGLE-FAMILY DETACHED UNITS (6) TOWNHOUSE UNITS W/ ACCESSORY UNITS (12 UNITS TOTAL) (io)TOWNHOUSE UNITS NOTE: THE TYPICAL NUMBER OF BEDROOMS IN THETH UNITS WILL BE (3) BEDROOMS. THE (6) BASEMENT ACCESSORY UNITS WILL BE 2 BEDROOM UNITS & THE UPPER TH UNITS WILL BE 2 BEDROOM UNITS. (no) - 3 BEDROOM UNITS, (6) - 2 BEDROOM UNITS, & (6) 2 BEDROOM UNITS THE SINGLE FAMILY DETACHED UNITS SHALL HAVE (3) OR (4) BEDROOMS. ALLOWABLE DENSITY: 65 UNITS PER APPROVED PRD REZONING & APPLICATION PLAN 65 TOTAL DWELLING U N ITS123.36 ACRES = DWELLING UNITS/ACRE PROPOSED DENSITY: 65 DWELLING UNITS/23.36 ACRES = 4.42 DWELLING UNITS/ACRE OPEN SPACE: REQUIRED: 3.83 ACRES PER APPROVED PRD REZONING & APPLICATION PLAN PROVIDED=4.3aAC OPEN SPACE A: 0.24 ACRES OPEN SPACE D: 2.25 ACRES OPEN SPACE B: 0.44 ACRES OPEN SPACE E: 2.44 ACRES OPEN SPACE C: 0.04ACRES NOTE: OPEN SPACE TO BE OWNED AND MAINTAINED BY THE HOMEOWNERS ASSOCIATION. ALL OPEN SPACE SHALL BE RESERVED IN A DEED FOR COMMON USE OF LOTS OWNERS IN THE SUBDIVISION. RECREATION AREA: OPEN SPACES D & E SHALL PROVIDE ACTIVE & PASSIVE RECREATIONAL AMENITIES, INCLUDING A WALKING TRAIL ALONG THE STREAM AS SHOWN ON THE SITE PLAN SHEETS. ACTIVE RECREATION SHALL BE PROVIDED WITHIN OPEN SPACE B, INCLUDING A GRASS RECREATIONAL FIELD, MEETING AREA, AND PLAYGROUND EQUIPMENT. TOTAL RECREATIONAL AREA REQUIRED: zoo SF x 65 UNITS = 13,000 SF (o.3oAC) TOTAL RECREATIONAL AREA PROVIDED: 29,267 SF (0.44 ACRES) BUILDING HEIGHTS: NO MINIMUM HEIGHT REQUIREMENT. MAXIMUM - 35 FEET PER PRD REZONING APPLICATION PLAN SETBACKS: FRONTSETBACK:5'MIN. SIDE SETBACK: 5' MIN. REAR SETBACK: 20' MIN. (EXCEPT FOR UNITS ADJACENT TO VERA RUBIN PLACE WHICH SHALL HAVE A 5' REAR SETBACK) GARAGE SETBACKS: a8' MIN. NOTE: FRONT LOADED GARAGE UNITS, THE PORCH OR BUILDING FACE SHALL BE A MINIMUM OF FEETCLOSERTO THE STREET AS MEASURED FROM THE FACE OF THE GARAGE DOOR. SUBDIVISION STREETS: CURB & GUTTER WATERSHED: MOORES CREEK (MOORES CREEK IS NOT A WATER SUPPLY RESERVOIR WATERSHEDAREA) AGRICULTURAL/FORESTAL DISTRICT: NONE TOPOGRAPHY& SURVEY: BOUNDARY ANDTOPOGRAPHY INFORMATION WAS PROVIDED BY ROGER RAY & ASSOCIATES, INC IN FEBRUARY, 2020. FIELD VERIFIED BY COLLINS ENGINEERING IN FEBRUARY OF 2021. DATUM: NAVD 88 EXISTING VEGETATION: PARTIALLY WOODED WITH (2) EXISTING RESIDENTIAL HOUSES PRESERVED MANAGED SLOPES: MANAGED AND PRESERVED STEEP SLOPES ARE SHOWN WITHIN THE LIMITS OF THE PROPERTY. SEE EXISTING CONDITIONS SHEET 2 FOR LOCATIONS. LIGHTING: NO STREET LIGHTING IS PROPOSED WITH THIS PROJECT. PARKING: TWO (2) OFF-STREET PARKING SPACES ARE PROVIDED FOR EACH DWELLING UNIT AND (i) OFFSTREET SURFACE PARKING SPACE IS PROPOSED FOR EACH ACCESSORY UNIT. ADDITIONAL PARKING SPACES PROVIDED ALONG THE PROPOSED ROADWAYS. PARKING REQUIRED: 59 RESIDENTIAL UNITS ==8 PARKING SPACES 6 ACCESSORY UNITS = 6 PARKING SPACES 22 ATTACHED UNITS x (i PARKING SPACE/4 UNITS) = 6 SPACES TOTAL PARKING REQUIRED: 230 PARKING SPACES PARKING PROVIDED: GARAGE PARKING SPACES: 53 GARAGE PARKING SPACES DRIVEWAY PARKING SPACES: 65 DRIVEWAY PARKING SPACES SURFACE PARKING SPACES: 9 SURFACE PARKING SPACES ON -STREET PARKING SPACES: 4 TOTAL ON -STREET SPACES TOTAL PARKING PROVIDED: 3.32 SPACES BUILDING SITES: EACH LOT CONTAINS A BUILDING SITE THAT COMPLIES WITH THE REQUIREMENTS OF SECTION 4.2.2 OF THE ALBEMARLE COUNTY ZONING ORDINANCE, LAND AREAS: OPEN SPACE: 187,744SF 4.31 ACRES (32.3%) LOTS: 265,375 SF 6.og ACRES (48.3646) ROW DEDICATION: 128,464SF 2.95 ACRES (22.1%) PROPOSED IMPERVIOUS AREAS: ROADS: 72,750SF SIDEWALKS: 29,450 SF BUILDINGS, PATIOS/DECKS: 93,178 SF DRIVEWAYS: 28,320 SF TOTAL IMPERVIOUS AREAS: 224,098SF (5.24ACRES) BURIAL SITES: NO CEMETERIES WERE FOUND DURING FIELD INVESTIGATION OF THIS PROPERTY. FLOODPLAIN: THERE IS NO FLOODPLAIN LOCATED ON THIS SITE. FEMA MAP ID 53.003Co426D DATED FEBRUARY 4, 2005. LANDSCAPING: A LANDSCAPING PLAN WILL BE PROVIDED WITH THE FINAL SITE PLAN IN . . STREET ACCORDANCE WITH ALBEMARLE COUNTY ORDINANCE SECTION 2.79 3 TREES ARE INCLUDED WITH THE LANDSCAPING DESIGN TO INCORPORATE STREET TREES EVERY 4o' ALONG THE ROADWAYS. RETAINING WALLS: RETAINING WALLS ARE PROPOSED WITH THIS PROJECT. SEE GRADING & DRAINAGE PLAN FOR WALL LOCATIONS. TRASH SERVICE: EACH LOT SHALL HAVE AN INDIVIDUALTRASH CONTAINER. UTILITIES: ALBEMARLE COUNTY WATER & SEWER AFFORDABLE HOUSING: AFFORDABLE HOUSING TO BE PROVIDED IN ACCORDANCE WITH THE APPROVED PROFFERS. TOTAL PROPOSED NUMBER OF AFFORDABLE HOUSES: io UNITS SEE LAYOUT SHEETS FOR LOCATION OF AFFORDABLE UNITS, AS SHOWN WITH AN ASTERISK (*) PHASING: THIS PROJECT SHALL BE DEVELOPED IN ONE PHASE. GALAXIE FARM SUBDIVISION T.M.ga-a3 COUNTY SCHOOL BOARD OF ALBEMARLE COUNTY, VIRGINIA D.B.1033-313 D.B.2033-313 D.B.629-368 PLAT 40 LOT 3 LOT 38 / LOT 37 T.M.goA.a-E AV IN ESTATES LLC AVINITY ESTATES OPEN SPACE E D.B.2267-750 D.B.5124, PG.676 A VSMP PLAN AMENDMENT #2 (AMENDMENT TO WP0202000037) GMPHIC/ SCALE ( INS 8T ) 1 inc 80 ft. 33 SCOTTSVILLE MAGISTERIAL DISTRICT ALBEMARLE COUNTY, VIRGINIA L9 Je \ LOT 30 , T.M.9a-a6D SCOTTSVILLE ROAD HOLDINGS,LLC CIO KAPPA SIGMA FRATERNITY D.B.3257, PG.7o2 D.B.550, PLAT6o8 T.M.9a-aa SCHOOL BOARD COUNTY OF ALBEMARLE,VIRGINIA D.B. 5258-620 D.B-979-46 & 47 PLAT OT \ OPEN ;�PACEA \ \ \ , OT 5 � \ Al � OPEN / CO tB SPACE B LOT aB , `` PROPOSED RECREATION AREA STREAM BUFFERS: THE STREAM BUFFERS SHOWN HEREON SHALL BE MANAGED IN ACCORDANCE WITH THE ALBEMARLE COUNTY WATER PROTECTION ORDINANCE BUILDING SITES. LOTS 1-59 SHALL EACH CONTAIN A BUILDING S17E THAT COMPLIES WITH SECTION 4.2.1. OF THE ALBEMARLE COUNTY ZONING ORDINANCE. PRIVATE STREET.- VERA RUBIN PLACE IN THIS SUBDIVISION MAY NOT MEET 774E STANDARDS FOR ACCEPTANCE INTO THE SECONDARY SYSTEM OF STATE HIGHWAY AND WILL NOT BE MAINTAINED BY THE DEPAR7MENT OF TRANSPORTA77ON OR THE COUNTY OF ALBEMARLE. OFFSITE DISTURBANCE. OFFSI7E DISTURBANCE IS PROPOSED WITH THIS PLAN ON THE ADJACENT AVINITY EST47ES PROPERTY, WHICH IS ALSO OWNED BY THE SAME DEVELOPER. AVAILABLE FIRE FLOW." 1,750 GPM AT MINIMUM 20 PSI ISO CALCULATIONS: MAXIMUM REQUIRED FIRE FLOW FOR RESIDEN77AL STRUCTURE IS 1,100 GPM. T.M.ga-w COUNTY OF ALBEMARLE,VIRGINIA D.B.a979.44,46&47PL, \ \ OT12 \ __ LOT as LOT a r , Lo LOT / Lora / r i / T 7 PHASE OT, 6 I OT 5 / OPEN` / / SPACED PHASE II LOT 4--'------- r a \ LOT I Z, a3 LOT / I I LOT r `� PHASE \ \ \ i \. NE \ 1 /J � LOT LDT LOT V v VAVAVAII 1 10 a ¢6 I OPEN n A v ' SPACE E V , \ \ \ PROPOSED 14 Y V •tip-F� LOT 3 / SWM FACILITY T.M.9a a6Aa�� SCOTTSVILLE ROAD HOLDINGS,LLC C/O KAPPA SIGMA FRATERNITY D.B.3257, PG.7oa D.B.wBo, a73 PLAT i SHEET LAYOUT �� �� ScoRo�Ez SCALE: 1" = 80' GENERAL BUILDING DEPARTMENT NOTES.- 1. WHERE THE FLOOD LEVEL RIMS OF PLUMBING FIXTURES ARE BELOW THE ELEVA77ON OF THE MANHOLE COVER OF THE NEXT UPSTREAM MANHOLE IN THE PUBLIC SEWER THE FIXTURES SHALL BE PR07ECTED BY A BACKWATER VALVE INSTALLED IN THE BUILDING DRAIN, BRANCH OF 774E BUILDING DRAIN OR HORIZONTAL BRANCH SERVING SUCH FIXTURES PLUMBING FIXTURES HAVING FLOOD LEVEL RIMS ABOVE 774E ELEVA77ON OF THE MANHOLE COVER OF THE NEXT UPSTREAM MANHOLE IN THE PUBLIC SEWER SHALL NOT DISCHARGE THROUGH A BACKWATER VALVE. 2. DUE TO REQUIRED DISTANCES FROM LOT LINES AND STRUCTURES AS REQUIRED BY THE NFPA, UNDERGROUND PROPANE TANKS MAY BE PROHIBITED. 774E BUILDER/DEVELOPER SHALL PLAN ACCORDINGLY. J. RETAINING WALLS GREATER THAN 3' IN HEIGHT REQUIRE A SEPARATE BUILDING PERMIT. WALLS EXCEEDING 4' IN HEIGHT REQUIRE A STAMPED ENGINEERED DESIGN. WALLS CROSSING LOT LINES REQUIRE AN EASEMENT. 4. ALL WATER LINES, SEWER LINES, AND FIRE LINES FROM THE MAIN TO THE STRUCTURE MUST HAVE A VISUAL INSPEC77ON PERFORMED BY THE BUILDING DEPARTMENT. NO7ES- 1) 77-#S PROPERTY DOES NOT LIE WITHIN AN AGRICULTURAL AND/OR FORESTAL DISTRICT 2) ONLY (1) DWELLING PER LOT SHALL BE PERMITTED. 3) STREET TREES SHALL BE PROVIDED ALONG ALL 774E PUBLIC S7REETS 50' (MAXIMUM) O.C. IN ACCORDANCE WITH VDOT AND ALBEMARLE COUNTY STANDARDS AND REZONING DOCUMENTS. 4) THIS PROPERTY IS NOT LOCATED 1417HIN A DAM INUNDA77ON ZONE. 5) ROADWAYS AND PAVED CIRCULATION AREA = 60,634 SF. 70 RICHMOND SOUTHERN PARKWAY MILL CREEK JO P 1NfERSTOe 6A PIEDMONT VIRGINIA COMMUNITY COLLEGE u MONTICELLO HIGH LAKE REYNOVIA i MOUNTAIN VIEW),ELEMENTARYLJ SCHOOL THIS Q/ PROJECT MILL CREEK r0A 4! SOUTH O� R P VSMP PLAN AMENDMENT#2: VICINITY MAP: SCALE: 1" = 2000' A A BELOW IS A SUMMARY OF THE PROPOSED REVISIONS TO THE APPROVED VSMP PLAN AMENDMENT #a WITH THIS VSMP PLAN AMENDMENT #2. A NEW RISER (STR. A14) AND OUTFALL SYSTEM IS PROPOSED, RELEASING RUNOFF TO . : A LEVEL SPREADER AND A VEGETATED FILTER STRIPTHIS ADDITION PROVIDES j 1 STORMWATER QUALITY TREATMENT ONSITE. i YARD DRAINS HAVE BEEN ADDED TO THE DEVELOPMENT SENDING ADDITIONAL i RUNOFF TO THE DETENTION BASIN W. THIS ADDITIONAL RUNOFF WILL RECEIVE i ATTENUATION IN THE BASIN, AND WILL REDUCE THE RUNOFF EXITING THE SITE < UNDETAINED. THE BASIN's GRADES AND RISER (STIR. A6) HAVE ALSO BEEN MODIFIED i WITH THIS AMENDMENT. AN UPDATED SWM ANALYSIS HAS BEEN COMPLETED & IS i ATTACHED. THIS ANALYSIS SHOWS COMPLIANCE WITH CHANNEL & FLOOD < PROTECTION REQUIREMENTS FOR THE ONSITE SUBAREAS A & B. THE ANALYSIS ALSO < j SHOWSTHE PEAK POST -DEVELOPMENT LOWS IN THE COW BRANCH STREA M DOWNSTREAM FROM THE GALAXIE FARM SUBDIVISION ARE LESS THAN THE PEAK i j PRE -DEVELOPMENT FLOWS AT THE POINT OF ANALYSIS (POA) SHOWN & LABELED ON SHEET12. APPROVED by the Albemarle County Community Development Department Date 08/02/2022 File WP0202000037 Amendment #2 WRC41VIA EROSION & SEDIMENT CONTROL EROSION CONTROL HANDBOOK SPECIFICA77ON NUMBER CE CONSTRUCTION ENTRANCE J..02 0CR CONS7RUC77ON ROAD J..03 STABILIZA77ON SF SILT FENCE 3.05 X x ST SEDIMENT TRAP J..13 SB SEDIMENT BASIN 3.14 OP OUTLET PROTEC77ON 318 RR R/PRAP 3.19 CD CHECK DAM 3.20 �' TEMPORARY SEEDING 3.31 PS PS PERMANENT SEEDING 3.32 OTREE PROTECTION 3.38 DC DC DUST CON7ROL 3.39 • •- PUMP AROUND DIVERSION Lic. No. 035791 7/6/22 F_ z w f z p O J U of �_ d of ZLU O :D N Z O O H .Q. o� LU z .. w o LU LU LU r4 N N R N L9 N') z W ZN � � w W N Q z [7 W N Q N Q Z> LLJ _J > \ cn / / LL LJJ Zo O < O U Q W U U) W 0 Ul Z V) W W J J~ U_ W LL1 I JI � Q F1 0 0 x Q o J N w � w (v � w a Un JOB NO. 202194 SCALE 1 "=80' SHEET NO. 1 STORMWATER MANAGEMENT AMENDMENT #2 NARRATIVE: POST -DEVELOPMENT STORMWATER MANAGEMENT PLAN, SCALE 1"=80' 1 1 I / / \ I / / / / / // TH OOVERVIEW F THIS VSMP AMENDMENT #2 WAS CREATED TO PROVIDE ONSITE WATER QUALITY TREATMENT AND TO DETAIN ADDITIONAL RUNOFF WITHIN THE /� / / " /< / 1 \ \ I I 1 I I I / / / \ • / / / / / / / / Q���� PROPOSED SWM FACILITY, WHILE SIMULTANEOUSLY REDUCING THE RUNOFF EXITING THIS DEVELOPMENT UNDETAINED. / \ / I j / / I I I I / / PROPOSED ESLIMITS O DISTURAN�E / / / � / 1 I // BOUNDARY DEFINES THE THE�OPO ED/ SCOTT R. LINS'Z. WATER QUALITY SUMMARY / J I I + ♦LEI. VRRM WATER QUALIT4 BO NO P. �-+ THE DEVELOPMENT REQUIRES THE REMOVAL OF 9.21 Ibs/yr OF PHOSPHOROUS. THE REMOVAL RATE IS BASED ON THE DEQ VRRM. THIS VSMP / / II ✓ -� / /� UPLAND r OFFSITE DRI�INAG@ TO RF7MAIN I , 100' OF OLF w/ A E\;EV.=6', a 7�� �TO AL BOUNDARY ARE/P�-12.72 ACRES. � I U Lie. No. 0357911n AMENDMENT #2 PROPOSES A LEVEL SPREADER THAT WILL DISCHARGE THE TREATMENT VOLUME TO A VEGETATED FILTER STRIP WITH TYPE B SOILS. I / UNDIyfURBED & T0,8E RO,I/1TED TO THE I 25' of CONC. FLOW W/ / �0 7�6�22 l / 1h� THIS BMP IS SUPPLEMENTED WITH THE BEST MANAGEMENT PRACTICE OF PURCHASING NUTRIENT CREDITS. SEE BELOW FOR A BREAKDOWN OF THE \ \ X / PRO�P JSED BYPASS STORM SEWER/ RUNOFF I ELEV.=14' & 825' OF CHNL. FLOW /�j ' / / / / tV PHOSPHOROUS REMOVALS ASSOCIATED WITH THIS PLAN AMENDMENT #2, AND SHEET 13A FOR THE LEVEL SPREADER & FILTER STRIP DESIGN. I \ / / / TO BE DIRECTED Ify'f0 STR. 4. I I .� ' '�'�s Gti z Overall Phosphorous Removal Rate Required = 9.21 Ibs/yr / / A \ ��0� NA 25% of the Phosphorous Removal Rate Required to be Onsite = 2.30 Ibs/yr � / Phosphorous Removal Rate Provided via previously purchased Nutrient Credits = 5.59 Ibs/yr �� Phosphorous Removal Rate Provided via a Vegetated Filter Strip with B Soils= 5.41 Ibs/yr \ f I Total Phosphorous Removal Rate Provided (Purchased Nutrient Credits + Vegetated Filter Strip) = 11.00 Ibs/yr Percent of Total Required Phosphorous Removal Rate Provided Onsite (min. 25% required)= 59 % \ / jai Overall Phosphorous Removal Rate Surplus / Credit = 1.79 Ibs/yr �� �� I oT i ���{tE CU PDA WATER QUANTITY SUMMARY I / M�'PRIV c -- / �� z THIS VSMP AMENDMENT #2 CONTINUES TO TREAT THE BULK OF THE DEVELOPMENT VIA A PROPOSED DRY DETENTION BASIN NAMED DETENTION BASIN / OT 3 - � 'A'. DETENTION BASIN 'A' PROVIDES STORMWATER QUANTITY TREATMENT, BUT NOT STORMWATER QUALITY TREATMENT, AND DISCHARGES INTO SITE \ I �� O OUTFACE #1. THIS AMENDMENT #2 SENDS MORE RUNOFF TO THE DETENTION BASIN, AND SUBSEQUENTLY DETAINS MORE RUNOFF BEFORE THE FLOWS _ �� _ 'I " ARE RELEASED TO SITE OUTFALL #1. THIS AMENDMENT #2 ALSO RESHAPES THE BASIN & MODIFIES THE RISER STR. A6. WITH THESE IMPROVEMENTS, I a k O a THIS AMENDMENT #2 SENDS LESS DRAINAGE TO SITE OUTFALL #2 UNDETAINED AND REDUCES THE PEAK RUNOFF RATES EXITING THIS DEVELOPMENT VA TO THE COW BRANCH STREAM. �. RROPOSED�STOW SEWER �'� ' _ � � m rV 2 TO REDIRECT THEi OFFS TE CHANNEL PROTECTION & FLOOD PROTECTION REQUIREMENTS ARE MET FOR THE ONSITE SUBAREAS A & B. CHANNEL PROTECTION IS MET FOR THE - \ LO 4 / w ri Q \ \ \ \ \ - - - '� \ \ 1 \ \ RUNOFF THROUGH TH / ( ' \ 45' OF OLF w/ A ELEV.=B', Z o ONSITE RUNOFF VIA 9 VAC 25-870-66, SUBSECTION 6.3.a ENERGY BALANCE).THE LIMITS OF ANALYSIS FOR THE CHANNEL PROTECTION TERMINATE AT ' O z s THE SUBAREAS SINCE SUBSECTION 6.3.a IS SATISFIED. FLOOD PROTECTIONFORSUBAREAS A & B IS MET VIA 9 VAC 25-870-66, SUBSECTION C2.b \ �' \ 1 IMPROVEMEPOTS ASSOCIATED DEVELOPMENT, INTO STR 4 : 1. - - 300' OF CHNL FLOW _ O O I I (POST -DEVELOPMENT 10-yr PEAK FLOW < PRE -DEVELOPMENT 10-yr PEAK FLOW). THE LIMITS OF ANALYSIS FOR THE FLOOD PROTECTION ALSO ENDS AT UPLAND„OFFIT�E DRAINAGE T\REMAIN / -� WITH T S VSMP AMENDMENT #2, ___ -%'_ . ` - ����� �XIEF M" > z w o V U 0 BE ROUTED THE DIRECT NG ADD TIONA RUNOFF / V ONSITE DA 'B' Lu p o THE SUBAREAS SINCE SUBSECTION C2.b IS MET. P Q U y�j -* , , ____---� �' -�'� //� w a c PTOO BE DIRECTED T . "` _ - Lu UNDISTURBED U BYPASS STOW -SEWER. SEWER. R F 1 - '� I I \ \ TO DETENTIO BAS TY `-_- // PLEASE SEE THE TABLES BELOW FOR A SUMMARY OF THE ONSITE AREAS USED IN THE CHANNEL &FLOOD PROTECTION COMPLIANCE. NDIST CTED INTO S�ES-1.Air .. _ Vol-�'�- - �' • l �I [n �n ONSITE SUBAREAS A & B w (USED IN THE CHANNEL & FLOOD PROTECTION CALCULATIONS) Area, 1-year Flow, 2-year Flow, 10-year Flow, I I I I I _X _56 OUTFACE #1 Pre -Development CN ac. cfs cfs cfs / - - - _ Onsite DA A Pre-Dev. 64 6.40 4.45 7.29 18.02 tr- -L--- / - - --1 ( ) Onsite DAB (Pre-Dev.) 64 3.00 2.10 3.43 8.46 64 9.40 6.55 10.72 26.49 Post -Development CN Area, 1-year Flow, 2-year Flow, 10-year Flow, II III I I I \ Onsite DA A (Post-Dev.) 78 8.67 0.35 1.22 21.56 l �- N � Onsite DAB (Post- Dev.) 83 0.73 1.73 2.34 4.28 �e L r ^' 79 9.40 2.08 3.56 25.84 / - -�� I / / I I 1 ( 1 /tl ` _ ,y. PROPOSED LEVEL SPREADER 'A'. LEVEL \ n o SPREADER W TO OUTFALL INTO A VEGETATED � FILTER STRIP WITH B SOILS. VEGETATED ° NOTES: � I � - � - I , ' � I � (�y;S FILTER STRIP TO TREAT RUNOFF FROM ONSITE -a 1. COLLINS ENGINEERING PERFORMED AN ENERGY BALANCE CALCULATION FOR THE ONSITE SUBAREAS A & B. THIS CALCULATION DETERMINED A - '�+�FY - DA 'A'. SEE SHEET 13A FOR DETAILS.' MAXIMUM PEAK FLOW OF 2.10 cfs WAS ACCEPTABLE TO BE IN COMPLIANCE WITH MINIMUM CHANNEL PROTECTION CALCULATIONS. THE PROPOSED VSMP AMENDMENT #2 MEETS THIS THRESHOLD. PLEASE SEE THE CALCULATIONS PACKET FOR DETAILS.- 2. THE ORIGINALLY APPROVED WPO 202000037 PLAN BY SHIMP ENGINEERING PERFORMED ENERGY BALANCE CALCULATIONS ALONG THE COW / / // O�J BRANCH STREAM AS WELL. SHIMP ENGINEERING USED THE 'REDUCTION METHOD' IN THEIR ENERGY BALANCE CALCULATIONS, AS SHOWN IN / / ) I - # .. - I I / J - THEIR 10/16/20 SWM CALCULATION PACKET. SHIMP ENGINEERING DETERMINED A 4.25 cfs RUNOFF REDUCTION WAS REQUIRED DURING THE 1-YR STORM EVENT TO MEET ENERGY BALANCE REQUIREMENTS FOR THE PROJECT. THIS VSMP AMENDMENT #2 REDUCES THE 1-YEAR RUNOFF BY 4.47 0� cfs, AS SHOWN ABOVE (6.55 2.08). THIS 4.47 cfs IS CONSISTENT WITH THE PREVIOUSLY APPROVED SHIMP ENGINEERING RUNOFF REDUCTION OF \ M M 4.52 cfs, AND EXCEEDS THE MINIMUM 4.25 cfs REQUIRED REDUCTION COMPUTED IN THE 10/16/20 CALCULATION PACKET. / / / , n.. , M- M- n - �� 3. THE PEAK 10-YEAR POST -DEVELOPMENT FLOWS ARE LESS THAN THE PEAK 10-YEAR PRE -DEVELOPMENT FLOWS, HEREBY SATISFYING FLOOD - , �� /� ,.emu �' i PPROVED AVINITY II SWM - L -� / NOTE: t / / x;: °'I - ��� / THE REAR DOWNSPOUTS FOR LOTS 1, 2, 12 14 & " PROTECTION REQUIREMENTS. PLEASE SEE THE CALCULATIONS PACKET FOR DETAILS. SITE OUTFACE #3 (REDIRECTS _... i '�i;.u, L FACILITY OUTFACE OMENDMENT #2 - f LA RAI E T RE IN I / 53-59 SHALL BE CONNECTED TO THE DRAINAGE UJ OFFSITE RUNOFF AROUND THE "rda- ?i. �-% = -osr /" _ TO WPO 201500057 - UNDi5TUR8 TO E ROUTE E \ SYSTEM OUTFALLING INTO DETENTION BASIN A'. PROPOSED DEVELOPMENT APPROVED AVINITYI - �� 00 `> \, -- PROPOSED -BYPASS STORM PROPOSED STOR EWER RUNG / > / i� SWM FACILITY 4 THE FRONT DOWNSPOUTS FOR LOTS 54-59 N IN ADDITION TO MEETING THE ONSITE CHANNEL &FLOOD PROTECTION REQUIREMENTS DISCUSSED ABOVE, THIS VSMP AMENDMENT #2 ANALYZED THE r /� % --- / � -�------�N/ER TO REDIRECT THE C DIN O STRU UR S 6 & B. I .- \ � � N o II `.\-�- / OUTFALL AMENDMENT \ _ I SHALL BE CONNECTED TO THE DRAINAGE FLOWS TO THE COW BRANCH STREAM AT THE POINT OF ANALYSIS, OR'POA' AS LABELED ON THIS SHEET. THE FLOWS IN THE COW BRANCH STREAM ARE I I ( ' ,�,,.,�,. ---- - FFSITE RUNOFF AROUND- OUTFALLING INTO DETENTION BASIN 'A'. o LESS IN THE POST -DEVELOPMENT STATE AT THE POINT OF ANALYSIS THAN IN THE PRE -DEVELOPMENT STATE. THIS ANALYSIS ACCOUNTED FOR THE - - - .,,�, TO WPO 201300044) `. j a ---_ \ 1 I SYSTEM - +. THE SUBJECT PROPERTY -� / 3 PROPOSED GALAXIE FARM IMPROVEMENTS OUTSIDE OF ONSITE SUBAREAS A & B THAT ARE RELEASED IN ANON -CONCENTRATED FASHION. PLEASE SEE '` ' � "" -- � ..- " "`� `'" ' THE TABLES BELOW FOR A SUMMARY OF THIS, AS WELL AS THE ATTACHED EXHIBIT SHOWING THE OVERALL WATERSHED TO THE COW BRANCH STREAM. °J PRE -DEVELOPMENT STORMWATER MANAGEMENT PLAN, SCALE 1'-80' // / LU e OVERALL FLOWS TO COW BRANCH STREAM (AT POA) \ I / , 100' OF LF w/ A ELEV.=10', / / � n / \ 265' of 4NC. FLOW W/ A ELEV.=42'// / o / / (USED TO CONFIRM POST -DEVELOPMENT FLOWS ARE LESS THAN PRE -DEVELOPMENT FLOWS 100' OF OLF w� A ELEV.=6% PROPOSED ESC/LIMI'rS O,F DISTURBANCE DOWNSTREAM FROM THE GALAXIE FARM DEVELOPMENT) // I I / 1 S / / / Ir25' of CONC. FLOW W A ELEV.=3 y. BOUNDARY DEFINES THE N OPO ED/ O //// 1 `l �^ VRRM WATER QUALITY BO ND•°po-V• TyP. N Area, 1-year Flow, 2-year Flow, 10-year Flow, / / /� UPLANDr OFFSITE DRAINAGE TO REMAIN % I I , • � TOTAL BOUNDARY AREA=12.72 AREES. / � I � Z � Pre -Development CN / UNDISTURBED & TO,BE ROUTED TO THE I / / ac. cfs cfs cfs / PROPASED BYPASSSTORM SEWER/ RUNOF� I �/ TO BE DIRECTED I 0 STR. 4. Onsite DA A (Pre-Dev.) 64 6.40 4.45 7.29 18.02 ♦ / Onsite DA B (Pre-Dev.) 64 3.00 2.10 3.43 8.46 Q o Offsite DAC (Pre-Dev.) 58 226 13.58 27.35 68.39 / l \ �� �� y / �/ > a Offsite DAD (Pre-Dev.) 57 146 7.95 17.72 47.84 �� ���� Avinity I Routings 61.9 35.37 3.41 4.74 37.20 o Avinity II Routings 80.5 7.95 1.04 2.09 8.50 w a Spring Hill Village DA'A' Routings 74.4 19.10 2.34 12.60 39.91 \ \ \ f / / / / , \ LU o Spring Hill Village DA'B' 72 12.25 7.41 11.54 25.66 ` \ / / I I I / / / U/ LU 59 456.07 42.28 86.75 253.99 ! \ ) / / / / / / \ \ \ ; ^� / 2 � W LLI 0 PDA Area, 1-year Flow, 2-year Flow, 10-year Flow, \ / r / / J r Q ' Post -Development CN ♦ V �/� ac. cfs cfs cfs / / - oN B/ / Z z Z Onsite DA A (Post-Dev.) 78 8.67 0.35 1.22 21.56 \ Q O Q o Onsite DA B (Post-Dev.) 83 0.73 1.73 2.34 4.28 1 15" CMP CULVERT RELEASES RUNOFF FROM Offsite DA C (Post-Dev.) 58 226 13.69 27.48 68.47 \ I \ OFFSITE AREAS ONTO THE SUBJECT \ �� �• U ( n Offsite DA D (Post-Dev.) 57 146 7.95 17.72 47.84 \\ �� \ \ \'�� PROPERTY. IN THE POST -DEVELOPMENT" //z l STATE THE RUNOFF WILL CONTINUA TO 0E I c Avinity I Routings 61.9 35.37 3.41 4.74 37.20 I \ / \ COLLECTED WITH A CULVERT & THP' RUNOFF / A > Avinity I I Routings 80.5 7.95 1.04 2.09 8.50 I 1 \ \ ' ' \ \ \ WILL OUTFALL INTO STR. 4. \ , /- / OS / E Spring Hill Village DA'A' Routings 74.4 19.10 2.34 12.60 39.91 / _� /i r Spring Hill Village DA'B' 72 12.25 7.41 11.54 25.66 h-�uP�ND,IOFF�ITit VR INAGE IV V Klz ry �� �� o j -' U DISTURBED &TO BE ROUTED H _ I , / // LLI z 60 456.07 37.92 79.74 253.42 POSEDBYPASS 'STOW -SEWER. F w' I I \ �,� I �/ ■ TO E DI I_CTtD INTO SAES-1. � \ _: `� �. _ 140 ' -' Post -Development DA A Impervious Areas Pre -Development DA A Impervious Areas 2 I I I I III \ / ( y / / -' O z --- Residences 76,625 sf Buildings 1Q175 sf I / - g �� II �� / �O L Driveways 27,700 sf Paved Roads 1Q000 sf I / / / 1 W r z Roads 44,950 sf Y Y I�� - - /Z/ �ON E A'� 1- '�fi, 0 o Paved Walkways & Driveways 1,025 sf / /'�/ Sidewalks 17,375 sf 21,200 sf I I / \ / / �� //�/ / / / / y�� /' I - / Z Cn r+ > Existing Impervious Areas toRemain 8,550 sf Pre -Development DABlmperviousAreas 175,200 sf Buildings 2,800 sf II II II II I f1/00-Ow/ L�EV./-/ue LL Post- Development DA B Impervious Areas Paved Roads 3,25Y50i0D FL W Residences 1,500 sf 4,100' OF OLF w/ .T,Paved Walkways & Driveways n° / 200' OF CON FLOW N�/ Roads 16,975 sf 10,825 sf \� /� mil/ / ✓�� //� / / / V. oo' O CH TI of n J Il I / �_ a ~ x Sidewalks 750 sf VRRM WaterQuality Im ervious Area Summary J I I l /`,//SOW ft/rs R�ACILITI' SED 19,225 sf tY p rY � I I �� //� �/ i � / / � � Proposed Impervious Areas to Offsite DA C Total Impervious Areas Undetained 32,450 sf Proposed Impervious Areas to Offsite DA D Total Impervious Areas Undetained 1,125 sf 219,450 5f w 0219 PPROVED AVINITY II SWM CHANNEL AND FLOOD PROTECTION SUMMARY - L- --� \�\ SCALE FACILITY OUTFACE (AMENDMENT #2 �� LAND, OF RAINAGE T RE IN /" = TO WPO 201500057) _ UNDiSTURB TO BE ROUTE TOE AS SHOWN Method of 9VAC25-870-66 Method of 9VAC25-870-66 Method of 9VAC25-870-66 Method of 9VAC25-870-66 _ _ . APPROVED AVINITY I _ PROPOSED STOR EWER RUNOFF Channel Protection Compliance Limits of Analysis for Channel Protection Flood Protection Compliance Limits of Analysis for Flood Protection SWMOUT FACILITY C D I o STRU uR S 6 & 8. p Y P Y ( I I 4 , �SHEET N0. n OUTFACE AMENDMENT �__ m Onsite Subareas A & B Section B.3.a (Energy Balance) N/A (Energy Balance Satisified) Section C.2.b (10-yr Post < 10-yr Pre) N/A (Section C.2.b) ff 7o wao zol3000aa) Y -� UI \ % �12 / - - / =. , , DRY DETENTION BASIN CONSTRUCTION NOTES: FACILITY PLANTING SPECIFICATIONS: 1. THE DETENTION BASIN SHALL HAVE TURF GROUND COVER, SUCH AS GRASS OR SOME OTHER FORM OF A VEGETATIVE GROUNDCOVER. LANDSCAPING BEYOND THIS IS OPTIONAL AND IS NOT REQUIRED. 2. THE PROPOSED INTERIOR SIDE SLOPES OF THE BASIN SHALL BE A MAXIMUM OF 3:1 TO REDUCE THE RISK OF EROSION. THE PROPOSED FLOOR SLOPES SHALL BE GRADED TO PROVIDE POSITIVE DRAINAGE AT ALL TIMES TO THE RISER STRUCTURE. 3. WOODY VEGETATION SHALL NOT BE PLANTED OR ALLOWED TO GROW WITHIN 15 FEET OF THE TOE OF THE EMBANKMENT NOR WITHIN 25 FEET OF THE PRINCIPAL SPILLWAY STRUCTURE. 4. THE SOILS IN THE STORMWATER BUFFER AREA ARE OFTEN SEVERELY COMPACTED DURING THE CONSTRUCTION PROCESS, TO ENSURE STABILITY THE DENSITY OF THESE COMPACTED SOILS CAN BE SO GREAT THAT IT EFFECTIVELY PREVENTS ROOT PENETRATION AND, THEREFORE, MAY LEAD TO PREMATURE MORTALITY OR LOSS OF VIGOR. AS A RULE OF THUMB, PLANTING HOLES SHOULD BE THREE TIMES DEEPER AND WIDER THAN THE DIAMETER OF THE ROOTBALL FOR BALL -AND -BURLAP STOCK, AND FIVE TIMES DEEPER AND WIDER FOR CONTAINER -GROWN STOCK. 5. AVOID SPECIES THAT REQUIRE FULL SHADE, OR ARE PRONE TO WIND DAMAGE. EXTRA MULCHING AROUND THE BASE OF TREES AND SHRUBS IS STRONGLY RECOMMENDED AS A MEANS OF CONSERVING MOISTURE AND SUPPRESSING WEEDS. 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT OF ALL WORK COVERED UNDER THESE PLANS. 2. LANDSCAPE CONTRACTOR SHALL REFER TO THE STANDARDIZED LANDSCAPE SPECIFICATIONS FORTH ESTATE OF VIRGINIA FOR ADDITIONAL INFORMATION. THE CONTRACTOR SHALL ABIDE BY ITS CONTENTS; HOWEVER ANY NOTES OR SPECIFICATIONS ON THE PLANS SHALL SUPERSEDE THOSE OUTLINED IN THE SPECIFICATIONS MANUAL (COPIES ARE AVAILABLE FOR A FEE FROM THE VIRGINIA CHAPTER OF THE AMERICAN SOCIETY OF LANDSCAPE ARCHITECTS, VIRGINIA NURSERYMEN'S ASSOCIATION, INC. AND THE VIRGINIA SOCIETY OF LANDSCAPE DESIGNERS). ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF COLLINS ENGINEERING PRIOR TO THE CORRESPONDING CONSTRUCTION ACTIVITY. 3. ALL PLANT MATERIAL SHALL MEET THE MINIMUM SPECIFICATIONS AND STANDARDS DESCRIBED IN THE CURRENT ISSUE OF THE AMERICAN STANDARD FOR NURSERY STOCK, PUBLISHED BY THE AMERICAN ASSOCIATION OF NURSERYMEN, 1250 STREET, NW, SUITE 500, WASHINGTON, DC 20005. 4. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND NOTIFY THE DESIGNER OF ANY VARIANCE FROM THE PLAN. 5. THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE LOCATION OF ANY ONSITE UTILITIES (CALL MISS UTILITY AT 1-800-552-7001 BEFORE ANY EXCAVATION). 6. REFER TO THE APPROVED FINAL SITE PLANS FOR ANY DETAILED SITE INFORMATION. 7. ALL WORK SHALL BE COORDINATED WITH OTHER PARTIES. 8. PLANTS WILL BE PREPARED FOR SHIPMENT IN A MANNER THAT WILL NOT CAUSE DAMAGE TO THE BARK, BUDS, BRANCHES, STEMS, OR OVERALL SHAPE OF THE STOCK. CONTAINER GROWN PLANTS WILL BE TRANSPORTED IN THE CONTAINERS IN WHICH THEY HAVE GROWN. 9. ALL PLANT MATERIAL, UNLESS OTHERWISE SPECIFIED, SHALL BE UNIFORMLY BRANCHED AND HAVE A VIGOROUS ROOT SYSTEM. PLANT MATERIAL SHALL BE HEALTHY, VIGOROUS, AND FREE FROM DEFECTS, DECAY, DISEASES, INSECT PEST EGGS, AND ALL FORMS OF INFESTATION. ALL PLANT MATERIAL SHALL BE FRESH, FREE FROM TRANSPLANT SHOCK OR VISIBLE WILT. PLANTS DEEMED UNHEALTHY WILL BE REJECTED. 10. ALL CONTAINER STOCK SHALL HAVE BEEN PROPAGATED IN A CONTAINER LONG ENOUGH FOR THE ROOT SYSTEM TO HAVE DEVELOPED SUFFICIENTLY TO HOLD ITS SOIL. CONTAINER STOCK WITH POORLY DEVELOPED ROOT SYSTEMS WILL NOT BE ACCEPTED. 11. PLANTS NOT INSTALLED ON THE DAY OF ARRIVAL ON SITE SHALL BE STORED AND PROTECTED BY THE CONTAINER. OUTSIDE STORAGE AREAS WILL BE SHADED AND PROTECTED FROM THE WIND AND SUN. PLANTS STORED ON SITE SHALL BE PROTECTED FROM ANY DRYING AT ALL TIMES BY COVERING THE BALLS OR ROOTS WITH MOIST SAWDUST, WET BURLAP, WOOD CHIPS, SHREDDED BARK, PEAT MOSS, OR OTHER SIMILAR MULCHING MATERIAL. 12. THE OWNER RESERVES THE RIGHT TO SUBSTITUTE PLANT MATERIAL TYPE, SIZE AND/OR QUANTITY. ANY SUBSTITUTIONS MUST BE APPROVED BY THE INSPECTOR INITIALLY, AND THEN THE DESIGNER. 13. MINOR FIELD ADJUSTMENTS MAY BE NECESSARY DUE TO SITE CONDITIONS (EX: ROOTBALL AND UTILITY CONFLICT). MAJOR ADJUSTMENTS MUST BE APPROVED BY THE DESIGNER. 14. NO PLANTING SHALL OCCUR WHEN THE SOIL IS FROZEN. 15. PLANT MATERIAL SHALL BE PLACED IN EXISTING SOIL WITH EACH PLANTING PIT EXCAVATED TO A SIZE SUFFICIENTTO CONTAIN THE ENTIRE ROOT BALL OR ROOT MASS, WITHOUT CRAMPING ROOTSTOCK. 16. THE CONTRACTOR SHALL MAINTAIN A ONE (1) CALENDAR YEAR 90%CARE AND REPLACEMENT WARRANTY FOR ALL PLANTINGS. THE PERIOD OF CARE AND REPLACEMENT SHALL BEGIN AFTER INSPECTION AND APPROVAL OF THE COMPLETE INSTALLATION OF ALL PLANTS AND CONTINUE FOR ONE CALENDAR YEAR. 17. THE CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND DISPOSAL OF TRASH AND DEBRIS WITHIN THE LIMITS OF THE PLANTING ON A DAILY BASIS. 18. THE CONTRACTOR WILL NOT BE RESPONSIBLE FOR PLANT MATERIAL THAT HAS BEEN DAMAGED BY VANDALISM, FIRE, OR OTHER ACTIVITIES BEYOND THE CONTRACTOR's CONTROL. FACILITY CONSTRUCTION 1. DETENTION BASINS MAY SERVE AS SEDIMENT BASINS AND/OR TRAPS DURING PROJECT CONSTRUCTION. IF THIS IS DONE, THE VOLUME SHALL BE BASED ON THE MORE STRINGENT SIZING RULE (EROSION AND SEDIMENT CONTROL REQUIREMENTS VS. STORMWATER TREATMENT REQUIREMENTS). INSTALLATION OF THE PERMANENT RISER SHALL BE INITIATED DURING THE CONSTRUCTION PHASE, AND DESIGN ELEVATIONS SHALL BE SET WITH FINAL CLEANOUT OF THE SEDIMENT BASIN AND CONVERSION TO THE POST -CONSTRUCTION POND IN MIND. APPROPRIATE PROCEDURES SHALL BE IMPLEMENTED TO PREVENT DISCHARGE OF TURBULENT WATERS WHEN THE BASIN IS BEING CONVERTED TO AN DETENTION BASIN. 2. THE DETENTION BASIN SHALL ONLY BE CONSTRUCTED AFTER THE CONTRIBUTING DRAINAGE AREA TO THE POND IS COMPLETELY STABILIZED. IF THE PROPOSED POND SITE WILL BE USED AS A SEDIMENT TRAP OR BASIN DURING THE CONSTRUCTION PHASE, THEN THE FACILITY WILL BE DEWATERED, DREDGED AND RE -GRADED TO DESIGN DIMENSIONS AFTER THE ORIGINAL SITE CONSTRUCTION IS COMPLETE. MODIFICATIONS SHALL BE MADE TO THE RISER, ORIFICES AND BARRELS AS REQUIRED SO THAT THEY ARE CONSISTENT WITH THE FINAL CONSTRUCTION SPECIFICATIONS. 3. THE CONTRACTOR SHALL ASSEMBLE CONSTRUCTION MATERIALS ON -SITE, MAKING SURE THEY MEET DESIGN SPECIFICATIONS AND ARE PREPARED AT STAGING AREAS WHEN POSSIBLE. 4. THE CONTRACTOR SHALL CLEAR AND STRIP THE PROJECT AREA IF REQUIRED TO THE DESIRED SUB -GRADE. 5. INSTALL E&S CONTROLS PRIOR TO CONSTRUCTION OF THE BASIN, INCLUDING TEMPORARY DE -WATERING DEVICES AND STORMWATER DIVERSION PRACTICES. ALL AREAS SURROUNDING THE BASIN THAT ARE GRADED OR DENUDED DURING CONSTRUCTION SHALL BE PLANTED WITH TURF GRASS, NATIVE PLANTINGS, OR OTHER APPROVED METHODS OF SOIL STABILIZATION. 6. CONTRACTOR SHALL EXCAVATE THE CORE TRENCH AND INSTALLTHE SPILLWAY PIPE DURING THE ESC PHASE. 7. CONTRACTOR SHALL ALSO INSTALLTHE RISER, OUTFLOW STRUCTURE AND/OR THE BARREL(s) WITH PERMANENT COLLARS DURING THE ESC PHASE. CONTRACTOR SHALL ENSURE THE TOP INVERT OF THE OVERFLOW WEIR IS CONSTRUCTED LEVEL ATTHE DESIGN ELEVATION. 8. THE CONTRACTOR SHALL CONSTRUCT THE EMBANKMENT AND ANY INTERNAL BERMS IN 8-TO 12-INCH LIFTS, COMPACTION SHALL BE COMPLETED IN LIFTS WITH APPROPRIATE EQUIPMENT. THE CONTRACTOR SHALLALSO ADHERE TO THE CLAY LINER SPECIFICATIONS OUTLINED IN TABLE 14.4 BELOW: Table 14.4. Clay Liner SpecRcadons Property Test Method Unit Specification Perrneabiltty ASTM D-2434 CnI 1 x 10 Plasticity Index of Gay ASTM D-4231424 % Not less than 15 Liquid mdofClay ASTM D-2216 % Not less than 30 Clay Particles Passing ASTM D-422 % Not less than 30 Clay Compaction ASTM D-2216 % 95%of standard pfoctlordens 9. RADE UNTILTHE APPROPRIATE ELEVATION AND DESIRED CONTOURS ARE ACHIEVED FOR THE BOTTOM AND SIDE SLOPES OF THE BASIN. 10. CONTRACTOR SHALLTHEN CONSTRUCT THE EMERGENCY SPILLWAY IN CUT OR STRUCTURALLY STABILIZED SOILS. 11. THE CONTRACTOR SHALLTHEN FINISH CONSTRUCTION OF ALL OUTLET STRUCTURES, INCLUDING DOWNSTREAM RIP -RAP APRON PROTECTION IF APPLICABLE. 12. THE CONTRACTOR SHALL NEXT STABILIZE EXPOSED SOILS BY HYDROSEEDING OR SEEDING OVER STRAW. 13. THE CONTRACTOR SHALLTHEN INSTALLTHE APPROPRIATE BASIN LANDSCAPING IN ACCORDANCE WITH THE APPROVED PLANS IF APPLICABLE. FACILITY MAINTENANCE: MAINTENANCE OF THE DETENTION BASIN IS DRIVEN BY ANNUAL INSPECTIONS THAT EVALUATE THE CONDITION AND PERFORMANCE OF THE FACILITIES. DURING THESE INSPECTIONS THE FOLLOWING TASKS SHALL BE PERFORMED BY THE CONTRACTOR IN THE FIRST YEAR FOLLOWING INSTALLATION, AND THE OWNER THEREAFTER: 1. MEASURE SEDIMENT ACCUMULATION LEVELS IN THE BASIN. 2. MONITOR THE GROWTH OF THE GROUNDCOVER AND ANY TREES AND SHRUBS PLANTED, AS APPLICABLE. RECORD THE SPECIES AND THEIR APPROXIMATE COVERAGE AND NOTE THE PRESENCE OF ANY INVASIVE PLANT SPECIES AS APPLICABLE. 3. INSPECTTHE CONDITION OF STORMWATER INLETS TO THE BASIN FOR MATERIAL DAMAGE, EROSION OR UNDERCUTTING. 4. INSPECTTHE BANKS OF UPSTREAM AND DOWNSTREAM CHANNELS FOR EVIDENCE OF SLOUGHING ANIMAL BURROWS BOGGY AREAS WOODY GROWTH OR GULLY EROSION THAT MAY UNDERMINE EMBANKMENT INTEGRITY. 5. INSPECT BASIN OUTFALL CHANNEL FOR EROSION, UNDERCUTTING, RIP -RAP DISPLACEMENT, WOODY GROWTH, etc. 6. INSPECT CONDITION OF PRINCIPAL SPILLWAY AND RISER FOR EVIDENCE OF SPALLING JOINT FAILURE LEAKAGE CORROSION OR OTHER FAILURES. 7. INSPECT CONDITION OF ALL TRASH RACKS, REVERSE SLOPED PIPES OR FLASHBOARD RISERS AS APPLICABLE FOR EVIDENCE OF CLOGGING, LEAKAGE, DEBRIS ACCUMULATION OR OTHER FAILURES. 8. INSPECT MAINTENANCE ACCESS TO ENSURE IT IS FREE OF WOODY VEGETATION AND CHECK TO SEE WHETHER VALVES MANHOLES AND LOCKS CAN BE OPENED AND OPERATED. 9. INSPECT INTERNAL AND EXTERNAL SIDE SLOPES OF THE BASIN FOR EVIDENCE OF SPARSE VEGETATIVE COVER, EROSION, OR SLUMPING. 10. OWNER OR CONTRACTOR SHALL MAKE NEEDED REPAIRS IMMEDIATELY. FACILITY INSPECTION: MULTIPLE INSPECTIONS ARE CRITICAL TO ENSURE THE BASIN(s) ARE PROPERLY CONSTRUCTED. BECAUSE THE TIMING OF THE INSTALLATION IS DICTATED BY THE CONTRACTOR, THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING THE ENGINEER AND INSPECTOR PRIOR TO INSTALLATION. MULTIPLE SITE VISITS AND INSPECTIONS ARE REQUIRED TO BE SCHEDULED BY THE CONTRACTOR WITH THE ENGINEER AND INSPECTOR DURING THE FOLLOWING STAGES OF THE DETENTION BASIN's CONSTRUCTION PROCESS: 1. PRE -CONSTRUCTION MEETING 2. INITIAL SITE PREPARATION (INCLUDING INSTALLATION OF PROJECT E&S CONTROLS) 3. EXCAVATION/GRADING (e.g., INTERIM/FINAL ELEVATIONS) 4. INSTALLATION OF THE EMBANKMENT, THE RISER/PRIMARY SPILLWAY, AND THE OUTLET STRUCTURE(s). 4. DETENTION BASIN INSTALLATION e.. INTERIM AND FINAL ELEVATIONS 5. PLANTING PHASE (WITH AN EXPERIENCED LANDSCAPE ARCHITECT PRESENT/DIRECTING IF APPLICABLE) 6. FINAL INSPECTION (DEVELOP A PUNCH LIST FOR FACILITY ACCEPTANCE) nceVirgnwater Management Handbook {1999) nn THE FAAOAs KNI GRADING ruo General Construction notes for Stormwater Management Plans 1. All dams and constructed fill to be within 95% of maximum dry density and 2% of optimum moisture content. All fill material to be approved by a geotechnical engineer. A geotechnical engineer is to be present during construction of dams. 2. Pipe and riser joints are to be watertight within stormwater management facilities. 3. For temporary sediment traps or basins which are to be converted to permanent stormwater management facilities; conversion is not to take place until the site is stabilized, and permission has been obtained from the County erosion control inspector. GENERAL SWM NOTES: 2. STATE APPROVED TRASH RACKS SHALL BE INSTALLED ON ALL ORIFICE OPENINGS. SEE THIS SHEET, OR EQUIVALENT, FOR DETAILS. 2. CONCRETE FOUNDATIONS SHALL BE INSTALLED ON ALL RISER STRUCTURES MEETING MINIMUM VESCH 3.14 SPECIFICATIONS. 3. CONTRACTOR SHALL HIRE ATHIRD PARTY GEOTECHNICAL ENGINEER TO ENSURE THE EMBANKMENTS ARE STRUCTURALLY SOUND. ALL EXISTING AND PROPOSED FILL MATERIAL AND PROPOSED CONSTRUCTION SHALL BE APPROVED BY AN ONSITE GEOTECHNICAL ENGINEER PRESENT DURING THE CONSTRUCTION OF THE EMBANKMENTS AND FILL AREAS, AND PRESENT DURING THE CORE SAMPLING. 4. THE DOWNSTREAM EMBANKMENT SIDE SLOPES OF ALL PERMANENT FACILITIES SHALL HAVE A MAXIMUM 3:1 SLOPE. 5. CONTRACTOR SHALL EXCAVATE SEDIMENT LADEN MATERIAL IN THE ESC SEDIMENT BASINS ATTHE TIME OF THE FACILITIES' CONVERSIONS TO PERMANENT SWM FACILITIES, IF APPLICABLE. AT SUCH TIME THE CONTRACTOR SHALL REGRADE THE SEDIMENT BASINS TO THE PROPOSED GRADES SHOWN ON THE SWM SHEETS. THE CONTRACTOR SHALL MINIMIZE SOIL COMPACTION DURING THE CONVERSIONS. ALL SLOPES GREATER THAN 3:i SHALL BE PLANTED WITH NON -EROSIVE LONG GRASSES OR OTHER TYPES OF NON -EROSIVE PLANTINGS. SECTION A-9: TYPICAL GRAPHICAL DETAELS Homogeneous till - - - - -------1 1 I 4' min �\ Cut off trench-4- below suitable ) material Sal or rock L-----------, TYPICAL HOMOGENEOUS EMBANKMENT Perforated a FOUNDATION DRAIN Blanket drain BLANKET DRAIN III or grovel / dMin Sorel, qr. Or ral dlou outlet Rode or gravel Rat Fa Aftin aTronsition tiller Tronvillim filter CHIMNEY DRAIN TOE DRAIN Figure A -la. Homogeneous Embankments ts: Seepage Controls EMBANKMENT NOTES: THE EMBANKMENTS SHALL HAVE A COMPACTED CLAY CORE WITH A CUTOFF TRENCH & BE IN ACCORDANCE WITH THE DETAILS SHOWN IN THIS PLAN. BERMS AND SPILLWAYS SHALL BE STABILIZED WITH EC-3 MATTING & RIPRAP AND THE REMAINING DISTURBED SLOPES SHALL BE STABILIZED WITH EC-2 MATTING. ALL BERM FILL MATERIAL SHALL CONSIST OF ML, CL, SC OR GC SOILS & BE FREE OF WOOD, ROOTS, ROCKS OR ANY OTHER NON COMPACTING SOIL. COMPACTED FILL SHALL BE PROCTOR MAXIMUM DRY DENSITY ASTM D698 AND HAVE A MINIMUM OF 95%OF MAXIMUM DRY DENSITY AND 2%OF OPTIMUM MOISTURE CONTENT. ALL FILL MATERIAL AND CONSTRUCTION SHALL BE APPROVED BY AN ONSITE GEOTECHNICAL ENGINEER PRESENT DURING THE CONSTRUCTION OF THE EMBANKMENTS AND FILL AREAS. StermRJgxTM ROUND SERIES TRASH RACK (OR EQUIVALENT) CONCRETE MANHOLE STANDARD 60 INCH RACK SHOYVN DIMENSIONS IN INCHES PLAN StormRI Round Series for Concrete Manhole Part Nor Blow Dim Is dlmC Min ID MIIOD RS-24 17k 14% 28 - 24 3D RS-36 21W 14 40 36 43 RS48 27 18 57 RS-60 27% .V, 66?i 6o 70 Plastic SOIUUons, Inc. CUSTOMER PO Box 4356, N'Irclrsicr, VA 12604 23e NkC3ei W. WmJxsttr, VA 22603 :977) 877-5727 phone PROJECT. 4540)722-2219 fax httµ//www.plutle-eoWtlon.em, Splash Block Instructions Before installation of the Splash Block, or any rain diverting accessory, make sure the grade around the foundation slopes away from the house. There should be a 6 inch fall in the first 10 feet from the house. s 10 Feet � 6 in 1 • xoe emucruxwr vwncer MA9rC90rUnP19. IX4 ISOMETRIC CONCRETE STRUCTURE DIMMEONS INSIDE STRUCTURE DIMENSION OUTSIDE STRUCTURE DIMENSION AVAILABLE OPTIONS CROSS BRACING FOR OVERHANG HDPE ANTI -VORTEX PLATE DAM DRAWN P. APPO BY: DETAIL Patent -pending cut-out to allow for fitment of downspout with low clearance of elbow Water directing chevron pattern reduces washout AMERIMAX amerimax.com 1 800-347-2586 mfnrrrlamwn... rnm Hole for landscape spike at front of splashblock allows it to be secured to ground BASIN A DETAIL, SCALE 1"=3D' I - ^ /I 0 CONTRACTOR SHALL FASTEN A 12 GAUGE STEEL PLATE TO THE INSIDE OF THE CONCRETE STR. A6's RISER WHERE STR. AS's 018" OPENING IS LOCATED. STEEL PLATE TO BE CONTRACTOR SHALL FASTEN A 12 GAUGE FASTENED VIA GROUT, OR IN A SIMILARLY SUFFICIENT STEEL PLATE TO THE CONCRETE STR. A6 MANNER, AND SHALL COVER THE UPPER io"OF THE RISER VIA GROUT, ORIN A SIMILARLY / \ OPENING. BLOCKING THE UPPER io"OF THE OPENING SUFFICIENT MANNER, TO PLUG ITS / WILL REDUCE THE OPENING's AREA, RESULTING IN AN OPENING. STEEL PLATE TO COVER THE / EQUIVALENT AREA TO A 12" OUTFALL PIPE. STEEL PLATE AMENDMENT ft s 05" LOW -FLOW ORIFICE I TO EXTEND BEYOND THE LIMITS OF THE 018" OPENING & OPENING(INV.=47o.o0). STEEL PLATE TO TO BE INSTALLED AT THE TIME OF THE CONVERSION FROM EXTEND BEYOND THE LIMITS OF THE OS" A TEMPORARY ESC BASIN TO A PERMANENT SWIM BASIN. OPENING & TO BE INSTALLED AT THE TIME F THE CONVERSION FROM ATEMPORARY \ CONTRACTOR SHALL RETROFIT THE ASBUILT STR. A6 RISER. THE AMENDMENT #Vs LOWER ESC BASIN TO A PERMANENT SWM BASIN. SECTION SHALL REMAIN, WHICH CONSISTS OF A VDOT STD. B-1 (CONCRETE MANHOLE BASE WITH A 048") & A REINFORCED CONCRETE FOUNDATION. THE ASBUILT STR. A6's 05" / LOW -FLOW ORIFICE OPENING SHALL BE PLUGGED WITH A STEEL PLATE. SIMILARLY, A 018" OPENING FOR STR. AS PORTION OF THE RISER's 018" OPENING FOR STR. AS SHALL BE BLOCKED WITH A STEEL RISER STR. A6 � � / TO BE PARTIALLY BLOCKED. � PLATE. SEE STR. A6 PLUGS DETAIL ON THIS SHEET. ABOVE THESE TWO PLATES, THE RISER'S UPPER RINGS SHALL BE REMOVED. NEW UPPER 48" RINGS SHALL BE INSTALLED - - -- - - - WITH A RIM ELEVATION OF 481.50'. UPPER 048" RINGS TO INCLUDE (5) FIVE Oil3" 05" LOW -FLOW ORIFICE ---- MID -FLOW ORIFICES WITH INVERT ELEVATIONS=479.75'. IF THE STRUCTURAL INTEGRITY TO BE PLUGGED. IS NOT MAINTAINED WITH THE RETROFIT, CONTRACTOR SHALL REMOVE & REPLACE STR. A6 WITH A NEW RISER & FOUNDATION MEETING THIS PLAN's SPECIFICATIONS. ALL STR. A6 PLUGS DETAIL ORIFICE OPENINGS SHALL HAVE STATE APPROVED TRASHRACKS, TYPICAL. SEE THE NOT TO SCALE DETAILS WITHIN THIS SET FOR ADDITIONAL INFORMATION. io' WIDE TOP OF _ - 485 ELEV.1-484.0( MH-2 (60" ^�� ID) 2 INV IN: 471.30 (4) INV IN: 468.90 (A3) INV OUT: 468.80 (1) 2 EMBAN MENT ACCO DANCE / THE DE IGNS S OWN WTHIN THIS SET. 2 10' ELIEV.TO 4.00 M �' PROPOSED 485 , 485 480 GRADE PROPOS D VDOT STD. EC 1, CLAS 148 100-yr PEAK WSE1482.97 ry STR A4 FILTER ABRIC NDERLA MENTT 10-yr PEAK WSE=481.98 VDOT MH-1 EXTENDTO THE CHANN 's BANK 2-yr PEAK WSE-479.93 RIM-478.28' ONTRA OR SHALL NOT MPACT T E 1-yr PEAK WSE=478.63 -- 11=469.16 TREAM' CHANNEL WITH HE BYPASS 0� 10-469.06 (A3) STORM SEWE INSTAL ATION. 480 480 475 { (L=110' , W,=1 .5, W2 8', D=2) 47 EXISTING PRO PO OS-_D 2 GRADE PROPOSED 40' WIDE VDOT CL. Al RIPRAP PROPOSED BASIN s FLOOR SHALL PROPOS D VDOT LINED EMERGENCY SPILLWAY w/4:1SIDE ES PEDTODRAINTOTHE SLOPES & FILTER FABRIC UNDERLAYMENT. T . A14 ISER (o.5%MIN.) WITH 468.2 ' SPILLWAY CREST ELEV.= 4 2.5o. 2 475 LOPES THROUGHOUT. STRq , 124.80 LF OF 47 o TO PREVENT FLOTATION THE RISER BASE INV OU 469.9 SHALL BE FIRMLY EMBEDDED 6" INTO AN 18" STR A3, 26.3 LF OF THICK REINFORCED CONCRETE FOUNDATION 018 HOPE @ 0.61% THAT IS 8'x8', AND BURIED BELOW GROUND. S R 1, 36. 2 LF OF EXISTIN 0 6 HOPE ROXIMA E LOCATION OF 470 GRADE 470 465 EXISTING8" ANITARY SEWER jn/A 46 "i OrO Jcli O O OJ J 0 LO JJ W W 00 r-) N 00 W 7 rN to N00 Nroi 00 00 00 r- 1-- 00 00 1-- I-- 1-- r- - r M c0 (D (D W lei W 't 0+50 1+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 3+75 BASIN A SPILLWAY PRO FILE1°=5' S(CA V)LES BASIN A SECTION lT SCOTT/R. ClUINSZ H Lic. No. 035791,a p 7/6/22 4) In I- Z w f z � p O a- Z"M� 0 N O0 < F z a (ICI N N N L9 0-)LU I- z LLJ ZN � � Q - � z L W N Q z C7 WN Q z N /^� Q I..L Z z CW 0 Cn \ G W / W V Z o z z Q O Q W FI U , ^ H� QF--I Ul w 0 3: Z i� ''l 0 Z) Lr B� W V W V / tTtTJ U J~ LL W 0 W Q X UO Q � N F w w a- Lf) JOB NO. 202194 SCALE AS SHOWN SHEET NO. 13 VAACR D STORMWATER DESIGN SPECIFICATION NO. 2 SHEET FLOW TO FILTER OR OPEN SPACE KEY LEVEL SPREADER INTO EXISTING GRADE RIPRAP PLUNGE POOL RIPRAP APRON RF.ATm .1 TI MBERS OR CONCRETE LIP WL A LENGTH OF LEVEL SPREADER Oy LIP TO BE BASED ON DESIGN FLOW AND ALLOWABLE VELOCITY TOP OF LEVEL SPREADER - I A�A.Y SHALL BE FLAT 1-3 IN. COURSE AGGREGATE OR OTHER LINING AS DESIGNED FOR STABILITY PLAN VIEW DIMENSION BASED ON UNperuRBED EXltisaVOCMDE DESIGN DISCHARGE 5% r20:17 OR LEM IF W630ATSD FLTER STRIP OR GONSERVW 2' MIN �4 SPPE FF34T to FEET LE96 3 MIN 10 MIN S MIN 12 iI r--"..—a M1N. DEPTH BASEDO REQUIRED STONES sEcnON A -A Figure 2.4: Level Spreader: Pipe or Chanel Flow to Filler Strip or Fraser+pA-Conserved n Space 1 /2" zinc plates nook attached with a/8' fastener ®®® 2-I/E' din, holes ®®m lsomctric 1/4' HOPE plate (optiondl) pipe culvert HUPB sl al plastic with hole. 0 B-1/8' nol ea and 1/�" plate manutaelured by Plastic OOOSolutions lneor equal 0000 ,. Ke r-= =' •- a - q, -L'e=''e^Y•�;•r: • III with oplie4al plate e_Xt} i HDPE Ar..Wral plaetic wlth 2-I/R" holes and 1/4- plate SCCLIOR msnufaaturea by Plaslia Solutions Inc. or equal 8' she hole 0 0 e 0 0 00 0 0 et. ..ne singlBAP Flevation PLASTIC DEBRIS CAGE Ro Rox 49116 SOLUTIONS Rinower VA P2e04 INC. 877-877-8727 ns.pletio-[slun[.eoin Table 2.4. Vegetated Filter Strip Materials Specifications LEVEL SPREADER 'A' & VEGETATED FILTER STRIP DETAIL, SCALE 1"=30' LEVEL SPREADER NOTES: 1. FIRST 10' FROM LEVEL SPREADER LIP MUST BE 2% OR LESS. 2. TIE BACK ENDS OF LEVEL SPREADER INTO THE SLOPE TO AVOID SCOURING. 3. CONTRACTOR SHALL NOTIFY COLLINS ENGINEERING A MINIMUM OF i WEEK PRIOR TO THE CONSTRUCTION OF THE LEVEL SPREADER. COLLINS ENGINEERING's PRESENCE IS REQUIRED AT THE TIME OF THE LEVEL SPREADER's CONSTRUCTION SO THAT THE LEVEL SPREADER's FINAL LOCATION CAN BE FIELD VERIFIED. FINAL LOCATION MAY VARY SLIGHTLY FROM THE APPROVED PLAN IN ORDER TO PRESERVE A LARGE TREE(s). 4. CONTRACTOR SHALL USE A GEOTEXTILE FILTER FABRIC UNDERLAYMENT BELOW THE PROPOSED LEVEL SPREADER STONE. THE GEOTEXTILE FILTER FABRIC SHALL BE TENSAR TX-5 TRIANGULAR GRID, OR EQUIVALENT. Material Specification Quantity Pea Gravel (#8 or ASTM equivalent) or Diaphragm should be 2 feet wide, 1 Gravel where steep (6% +) use clean bank -run foot deep, and at least 2 inches Diaphragm VDOT #57 or ASTM equivalent (1-inch below the edge of pavement. maximum). Permeable 40% excavated soil, 40% sand, and 20% pea gravel to serve as the media for the Berm berm. Geotextile material appropriately selected for placement under rip rap or gravel to Fitter Fabrc effectively separate the stone from the ground below. Engineered Level Spreader lip should be concrete, metal, timber, or other rigid material; Level Reinforced channel on upstream of lip. VDOT EC-3. Spreader See Hathaway and Hunt (2006) or Hennco County Program Manual for attemate designs. Erosion Control Where flow velocities dictate, use woven biodegradable erosion control fabric or Fabric or mats that are durable enough to last at least 2 growing seasons. (e.g., VDOT Erosion Control matting EC-3). Mattis If existing topsoil is inadequate to support dense turf growth, imported top soil ( loamy sand or sandy loam texture), with less than 5% clay content, corrected pH Topsoil at 6 to 7, a soluble salt content not exceeding 500 ppm, and an organic matter content of at least 2% shall be used. Topsoil shall be uniformly distributed and liahtly tom acted to a minimum depth of 6 to 8 inches Compost Shall be denved from plant material and provided by a member of the Compost U.S. Composting Seal of Testing Assurance (STA) program, as outlined in Stormwater Design Specification No. 4. II 111:1a]y111tl:1:1y0:11I:1111:11111 a1.11-1a1:121oil] 1:74b1:1010 MAINTENANCE INSPECTIONS: ANNUAL INSPECTIONS SHALL BE CONDUCTED IN THE NON -GROWING SEASON DURING THE FALL AND WINTER MONTHS. INSPECTIONS SHALL TRIGGER MAINTENANCE OPERATIONS, AS REQUIRED. MAINTENANCE OPERATIONS MAY INCLUDE, BUT IS NOT LIMITED TO, SEDIMENT REMOVAL, PERIODIC MOWING, REPAIR OFTHE LEVEL SPREADER AND ENSURING A DENSE, HEALTHY VEGETATED GROUN DCOVER. MOWING SHALL BE COMPLETED AT LEAST TW ICE A YEAR TO PREVENT FURTHER WOODY GROWTH AND SPOT RE -VEGETATION OFTHE FILTER STRIP IS REQUIRED IN ORDER TO MAINTAIN Ago% MINIMUM COVERAGE RATE. THE CONTRACTOR SHALL CONDUCT THE INSPECTIONS FOLLOWING THE FIRST YEAR THE PROJECT IS COMPLETED, AND THE OWNER SHALL CONDUCT THE INSPECTIONS THEREAFTER. INSPECTIONS SHALL INCLUDE THE FOLLOWING AT A MINIMUM: i. ENSURE FLOW PATHS ARE NOT SHORT-CIRCUITED IN THE LEVEL SPREADER AND THROUGH THE VEGETATED FILTER STRIP. 2. ENSURE DEBRIS AND SEDIMENT HAS NOTACCUMULATED. 3. CHECK FOR SCOUR AND EROSION WITHIN THE LEVEL SPREADER SYSTEM AND FILTER STRIP. 4. CHECK FOR FOOT OR VEHICULAR TRAFFIC DAMAGE IN THE STONE. S. ENSURE VEGETATIVE DENSITY MEETS OR EXCEEDS go%OFTHE FILTER STRIP AREA. IN THE EVENT MAINTENANCE IS REQUIRED DURING THE ABOVE NOTED INSPECTIONS, CORRECTIVE MEASURES SHALL BE COMPLETED IMMEDIATELY. PROPOSED PUBLIC ROAD & SIDEWALK AND ` \\ / R i GRADED GRASS LINED ACCESS TO SERVE AS THEACCVEGETATED ETATO TR. A14FILTER STRIP. SPREADER'A'& \ \ \\ \ \ / ( / / THE VEGETATED FILTER STRIP. PROPOSED RISER STR. A14 & ITS Ew DOWNSTREAM PIPES TOCONVEYTHE TREATMENT VOLUME FLOW 0-10' MAX. SLOPE= 2% TO LEVEL SPREADER W & THE ` �P'r� 685 WATER QUALITY TREATMENT. I I // 9� n as A l �Z2 468.67— BEGINNING OF LEVEL SPREADER \ 467.50— BOTTOM OF LEVEL SPREADER 468.50— TOP OF LEVEL SPREADER / PROPOSED 43'LONG FLAT LEVEL \ LINING AND PLUNGE OA SLOPED D(MIRN.) VDOT CLIGID LIP. LS DAlRPRAPLNED O INCLUDE OEMBAN KM ENTP DOWNSTREAM FROM THE RIGID LIP EXTENDING TO THE FILTER STRIP. ALL / RIPRAPTO INCLUDE FILTER FABRIC UNDERLAYMENTS& BEA MIN. OF 6" DEEP. / S S —� S \ / � PROPOSED 43'WX35L' VEGETATED FILTER STRIP. FILTER STRIP TO BE UNIFORMLY GRADED TO THE SLOPES SHOWN ENSURE SHEET FLOW BELOW THE LEVEL SPREADER. CONTRACTOR TO TIEBACK GRADES AT 6:1 O NT SOIL COMPACTION BY HEAVY EQUIPMENT WITHIN THE E LIMITS rr �- \CJ t / ' OF THE FILTER STRIP SEE THIS SHEET FOR ADDITIONAL so-+ FILTER STRIP DETAILS &DESIGN REQUIREMENTS. SLOPE RANGE= 4% SITE OUTFACE ), SEE THIS SHEET FOR A SCALED \ PROFILE OF THE DRAINAGE ' SYSTEM, LEVEL SPREADER 'A'& Lill THE VEGETATED FILTER STRIP. \ IIIIIII�I— IIIIIIII �/ / / \�� •'� ��\��� llI0000. 1—woo sees C� ��� 1 I ( / TO PREVENT FLOTATION THE RISER BASE SHALL BE FIRMLY EMBEDDED 6" INTO AN 18" THICK REINFORCED Too' WPO ICONCRETE FOUNDATION THAT IS 4'4- / BUFFER, TYP. Vegetated Filter Strips Planting Requirements 0 Vegetated Filter Strips shall be )anted at such a density to achieve a 90 /o grass/herbaceous herbaceous 9 P P Y 9 / cover after the second growing season. Vegetated Filter Strips shall be seeded, not sodded. Seeding establishes deeper roots, and sod may have muck soil that is not conducive to infiltration (Wisconsin DNR, 2007). The filter strip vegetation shall consist of turf grasses, meadow grasses, other herbaceous plants, shrubs, and trees, as long as the primary goal of at least 90% coverage with grasses and/or other herbaceous plants is achieved. Vegetation at the toe of the filter, where temporary ponding may occur behind the permeable berm, shall be able to withstand both wet and dry periods. The planting areas can be divided into zones to account for differences in inundation and slope. Additionally, the trees selected to be planted shall be 10' on -center and shall be an even mix of River Birch (Betula Nigra), Red Maple (Ater Rubrum) and Sweetgum (Liquidambar Styraciflua). No trees shall be planted within the ACSA easement. TO PREVENT FLOTATION THE RIS SHALL BE FIRMLY EMBEDDED 6" INT THICK REINFORCED CC FOUNDATION THAT IS 4k4'. FOUL` TOP TO BE SET AT GRADE, BURY REMAINDER OF THE FOUN D O Z CD N W a N NFr STR: Al 24" RISER w/ TRASHRACK RIM=481.50' 485 INV.=469.75' ­11. (2-j" ORIFICE)z , /I CONTRACTOR SHALL CALL THE COUNTY R& ENGINEERING DEPARTMENT 24-HOURS BEFOREAN ANTICIPATED CONSTRUCTION ACTIVITIES FOR THE BIVI THIS IS INCLUSIVE OF WHEN THE LEVEL SPREADER IS READY FOR � \ � CONSTRUCTION, BUT BEFORE STRUCTURE A715 INSTALLED. NOTE: STRUCTURES Ag-A14, LEVEL SPREADER W AND THE FILTER STRIP SHALL BE INSTALLED ATTHE TIME OF THE TEMPORARY ESC BASIN'S CONVERSION TO A PERMANENT SWM FACILITY. .1 PROPOSED GRAD H 480 0 Z ^ 480 . a Li II PROPO ED WAL N N Y Z 475 RAINA STR. 3 E 468.67— BEGINNING 467.50— BOTTOM C ER BASE 468.50— TOP OF Ji AN z8" NCRETE DATION J ING THE XISTINGRADE JATION. 470 1.0' 470 _ STR 13— 7 C ' .53 LF \ OF 01 HDPE 0 0.57 STR 11— 11 .39 LF OF 01 HDPE @ 0.5 465 1 STIR -2.)465 012' HDPE 2.67 460 460 1 W W 00 O N 000 � M N N I J J ww N M7 O N N� N (30 w w 0+50 1+00 1+50 2+00 2+50 STR. A14 -FILTER STRIP PROFILE SCALES 1"=5' (V) 1"=50' (H) OF LEVEL SPREADER=STR. A9 INV. OUT F LEVEL SPREADER LEVEL SPREADER IROPOSED 43'WX35L' VEGETATED FILTER STRIP. FILTER iTRIPTO BE UNIFORMLY GRADED TO THE SLOPES SHOWN r0 ENSURE SHEET FLOW BELOW THE LEVEL SPREADER. :ONTRACTOR TO TIE BACK GRADES AT 6:1 & PREVENT SOIL :OMPACTION BY HEAVY EQUIPMENT WITHIN THE LIMITS DF THE FILTER STRIP. SEE THIS SHEET FOR ADDITIONAL :ILTER STRIP DETAILS & DESIGN REQUIREMENTS. PROPOSED 43' LONG FLAT LEVEL SPREADER W. LS TO HAVE A 12" DEEP PLUNGE POOL & A 6" WIDE RIGID LIP. LS TO INCLUDE A VDOT CL. Al RIPRAP LINING AND A SLOPED 3' (MIN.) VDOT CL. Al RIPRAP LINED EMBANKMENT DOWNSTREAM FROM THE RIGID LIP EXTENDING TO THE FILTER STRIP. ALL RIPRAP TO INCLUDE FILTER FABRIC UNDERLAYMENTS & BE A MIN. OF 6" DEEP. 1PPROXIMATE LOCATION OF :XISTING 8" SANITARY SEWER INV.=461.04't) /T SCOTT/R. C!1UINSZ Lic. No. 035791,a p 7/6/22 4) F- Z W z 0 O a a Z"DOr4 UU p N Z O O Q. F Z a (H � p n r► N N n N L9 O- z I� Uses!ZN � LU - � z W 0 a z � l n W N N H1 ZQ I� LULLJ a o J_j C I� G � J cn z (n > LU LLJ C I LU O 11�z Q W O�^ Q Y Hsesell y > LU Ul LEI Q ZU LLI W C GoC IIIIIIIJ ~ LL LLJ W Q H� 0 x U 0 Q 0 J N UQ W W 0-O U) JOB NO. 202194 FSCALE AS SHOWN SHEET NO. 1 Pie No. Size inches Easement Width Required feet Easement Width Provided feet 1 36 29.8 30 3 30 29.1 30 5 30 23.9 25 7 30 22.9 23 9 30 21.3 22 15 24 24.2 25 17 24 21.2 22 19 15 15.7 20 22A 24 15.8 20 21 15 15.7 20 23 24 21.4 Within SWM Esmt. 25 24 24.2 25 27 18 31.1 32 39 15 20.5 21 43 18 17.9 20 NOTE: VDOT WILL ONLY MAINTAIN WITHIN DRAINAGE EASEMENTS TO THE EXTENT OPO MONG PREWTED 49 B S 8 B 8 / / / / v \ \\ ) CCr'- F / P O/ SED s7/ HD EVAkD ' � / E INGWAOL_, 498BW - ALLA- NECESSARYTO PROTECT THE ROADWAY FROM FLOODING OR DAMAGE. 498E 0 4 1 A.3+oo TH 0 COLOBLUE RIDGE rj PP PROPOSED 8" HDPE YARD f 502 TW 6 BW �� DRAIJ7NV SY TEfvf w/ YD-4H 506 BG / L� 18" YARD DRAIN DRAIN SYSTEM w/ 30' / / 4@6 gG 49 ! PIj-IVAT DR INA / / 508 TW 498BG CO- G I / NOTE: WALLS o" AND HIGHER SHALL REQUIRE A HANDRAIL PRIVATE DRAINAGE qgq g \ `\� EA E -NI. 508 T 500(3G 505 BW _ 4 {7 3 TOP=49975 EASEMENT. / \ _ \ YD-4E D PG. / \ 498BW INV.=498.2$ DB_PG �5 Soo G \ SCOTT R. LINS'Z 50 TW YD B _ - - \ \/ CONY DEFINED / U Lic. No. 035791 a VARIABLE WIDTH WALL 4w I I PRESERVED STEEP �08 TW 49 gW \ 495 BG L \ / 500BG \ / ,. \� CCt�-4F / �o w & MAINTENANCE - - I SLOP S, TYP / 506�TW BW_ � I 498BW � A _ / A 4�29�22 Q' EASEMENT __ ...\ _ � SOOBG / 8° jo DB.PG. YD-41 \ \ - 1 LOT MATCM / / �� / / 8 BW 50 \ Ak S 500 TW / / TOP=501.33 /' 495 B \ / P DRA SY TE Dw/ 7°NAL 'G / P,O, S DD1 E,Y° D S G �ALLA INV.=49 5/ ,494BW S V A ov A (� i E \ Pam'"EASEEI STA9+00� YD 4 OT I / - A AV � YD 4E D 500 TW ALA / ' \ \ \ GAR=492.42 \ FFE=494.33 / / / LOT . < / - - I I \ \/ 499 \ 8 FFE=494.42 V � -____ "/ / / i' �' \ \ \ - ` I / yi494BW 0� �' �' V A � \ V � - / / 6 L A \ _�i . y 2 CO_L}C ) / ,VI �- YO-4A A - �� FFE=s�4.33 / / LOT / / C E / PROPOSED 18" YARD a o 62 \ \ / / / l I �I J t DRAIN INLET, TYP \ �� \ // \ YD-4D / A/V i�I'�pT F \ 9 \ �... LOT op /? `ff 49i p • ; I �07, / / / / / \ L / N 9 FFE=a9aso V / - PROP SE 21` 484 •� g \� \ PUBLIC DRAINAGE LOT �. ASEM NT GAR=492.50 \ 10 '%' 5' M N. H RI NT LSE ARA ION REO IR D BETWEE ' = J DB. G. FFE 494.50 / �� - a' .G0AOa n �-o. . 3;.1 cFFE=4�9� V V 4.,..• `m � 4 2g ACSAO�UTTo ILITIES -STORM V\ SEWER, AS SHOWN. TYPICAL. � �L1O AR=491.92 3.92 PROJECT -6 f491.13 t` BOUNDARY, V. - / i uG41,00e Pi 07 O 91.42A FE=4939 SMT=�83.7�<c GAR 493.3311 a.z%a9zs1 °• ?0 , ' / `' a . 12+00 H W y9Mo / �- 100' WP / r i V� � BU FER,7P.Ln - FFE=�}93.67 11 ( w 2: t LOT A 4901 s 1- w v - z+7a a9o.z9 / i y+oo w w MARK COURT 1 / �� �% - - 1 / / /,�,/ 12 3$A 39"" • CQ 1 -mow PR( D U LIC RO D / I CO BRANCH STREAM / Ln w t SLOPES STEEPER THAN 3:1 SHALL BE PLANTED WITH NATIVE STEEP SLOPE MIX I I I 3 w w 6 (49' PUB IC RAW) N z) J / / < H WITH ANNUAL RYEGRASS BY ERNST CONSERVATION SEEDS AT A RATE OF I\ 4� \ 01" $/ �j / / / % / / ) W Z f 6o LBS. PER ACRE, OR i LB PER i,000 SF, UNLESS SPECIFIED OTHERWISE (TYP) �,V I - - - 38 ' ( - - l \ •" g as w j/W'.. /491.26 i - /� , ^�rp' / / c �j"c - +M r • I I \ I � __ � 0 ..,.• • •9os5, // / / / /� 4909 Pf�OPOSED SEGME D y / PROPOSED to I I LOT \ \\ - ,"• STD: CD-z N \ RETAINING LL, / CONTRACTOR SHALL EXTEND EXISTING / PRIVATE DRAINAGE I I •\ \ - I I m, \ DIAMOiS PRO- / ULVERTSSHALL BE / CULVERT BENEATH RTE.zo WITH PROPOSED EASEMENT I I I �13 Gq.R=491.00 i1 75%a89 3]� NF GAR=491.83� _ i h COLOR: BLUE RIOUN�TTERSUNKA WIDENING. SEE PROFILE ON SHEET 21 FOR DB._PG. I I FFE=491.33 II N ' \ I LOT I / / \� NiMUM5F 6" ' / DETAILS, OF HE CULVERT EXTENSION. - I � \ i,� FFE=492.17 •� / I - o I I - GAR=ago 6 i A I 2 I I I I GA�2=491.0 \ / v� F z i w F- O Lu i W > m _ }u r O z O F > U) O O O} VO 1 a U 0 3 J 0 d a 0- a j i 0 w w w a w w Q w Ln 3- > Lu ALL B - � i ..--i .CN W T +54 BSMT LOT 00 N N N _ YDl D 3 \ 4 - \ 475 BAG( ���i 3 pp - / 474 B h� LU LLJ\ FFE-490.00 �I A .31+ 1- - I \ I � PROPOSED B"HDPE ROOF/ � PROPOSED 18" YARD V LOT ` ! FOUNDATION DRAIN w/1o' e _ DRAIN INLET, TYP. / PROPOSED DRAINAGE PRIVATE DRAINAGE EASEMENT \ 75 G ' VA 1 (z) PROPOSED 48" RCP LJJ A �I 4 _ 36A ' SYSTEM,TYP. '/ PG. C // / 480 4 BW 64 CULVERTS / J YD V� v - LLB ST 0+00 p 76 G/ / iC A 6 �� RF 9 48oya6 �P a7a UG CD 47p 11 1000, -MAIN CE 0 BG I _ \ \\ I -- ,' �.•� �� P ED 8'P TENAN/ /. D7 - ' 186 \ \ ,'"b a +IiI o `PROPOSEDVA EASE MENT Q - ��- PROPOSED VDOT / _ 8 / _ _ � 1Z _L9 O_ •. _ -____ 17+00 _ 3 E - 4 • PROPO E6 VDOT �{ r, LAN I _ �\ __ 0) PROPOSED 8"HDPE ROOF/ PRO SEDVID T STD�EW-1 Oi FOUNDATION DRAIN A -- SYSTEM w/io' PRIVATE STD. CD- 18C / PROPOSED VDOT (,. � T 16+00 15+pp _. __ --- . ___--- � �_/ OSEO PUB IC RI I. - WIDTH - DRAINAGE EASEMENT 18A STD. CD r PROPOSED VDOTD. V - 14+00 (VAR 47 rq � ; � - - a -- DB._PG. 35 / STCD-2 -�FF - OPOSED V OT +00 /�- � a � 1 STD: Cl 1- STD CD-2 (2) PROP CD PROPOSED VDO YYYYYY p 10' i LOT 34 - .. FFE 48900 � CULVERTS _ .� STD. CD-1 �, Cn IV DRAINAGE YD_ B 2.7% � �'� 3. ' BSMT- 78.83 �� / PROPOSED VDOTSTD. EW-7 5 GAR=490.67 - EASEMEN a DB. P � - F�E=491.00 54 RF A \ � 48 qz' � / � / / ALL - ST PROPOSED PUBLIC) ` ` G� - :LOT / / / DRAINAGE \`P V PHASE LINE l 72 TW EASEMENT �ROPOSED VDOT STD. EW-7 COUNTYDEFIN D .; ;" �I P� 15 / 72.678E � � CULVERTS SHALL BE _ ,5 �.9 LET tI MANAGED STE P� I ��`b"VARIABLE WIDTH WALL / 470 BW COUNTERSUNK A _ Q GAR=490.6 55 4 PROPOSED zz" SLOPES, TY 3 0 & MAINTENANCE / 472 6- TW 1 / MINIMUM OF 6" _ /' CULVERTS SHALL BE f d- I Q DRAIN IN Tw/01 \\ s FFE=491.00 �I CLEANOUT, TYP. - EASEMENT 468 7BG /t / V COUNTERSUNKA� r Lu H TYP ' - DB._PG._ COW BRANCH STREAM ; MINIMUM OF 6" / PROPOSE o' • I \ II / 466 78WI / / � �/ �`Z �\ L1J Q � I''� \ PUBLIC DRAIN I � PROPOSEDB HDPE YAR '� � �` � / W LLF-STA. O} • J `/ Y.7 LOT 1 ��SYSTEM 3l l I \ % J / EASEMENT \ r FFE=49100 56 / Irn \ O PRIVATE DRAINAG o' / I 47 .67T / I \ / O 1 I 2 47}.67 BG PROPOSED SEGMENTED -- > l r r{ \ PROPOSED zz' EMENT. 3 �, as ; '• / 4/p,67�)N l/ RETAINING WALL, �'' / � z o PUBLIC DRAINAGE L - a / / 1� DIAMOND PRO _111GAR\ EASEMENT �T �- /� - / \ COLOR:B-UE2�� =49 1.67 LOT, \ \ INTERMITT�ST�AM Lu DB.PG._ GAR aa7.00 LOT / �Q/ _ = �____= I U PROPOSED lz" HDPE ROOF/ .. �I FFE=489:00 3 w w E-491.00 57' • �� FOUNDATION DRAIN RO E V TBSMMF'---478'8 i6 / �' ' t J FF iPROPOSED lz" I Z. >- F I :� SYSTEM w/io' PRIVATE 3D / -- / \ ' ' ' O J CLEANOUT YP. Q 2 % LOT \ DRAINAGE EASEMENT - STD. CDa / ry o J// �N z `/' [1. > t LFFE 0.67 _�DVDOT / �` - Z'p� nLOT 1., 58 \ DB.t/ - STD. CD_z / / a / w PROPOSED PUBLIC � � � Q CXJ .LOT wa \ PROPOSED 18" _ �9 4..8 I �' ' / 3o'DRAINAGE ,���0� \ `�' _ GA �95.30 52 / J" 53 a I DRAIN INLET, TYP. 0 \ 2 2 /'�� PROPOSED RIP LINED ^ r EASEMENT QP J �(� \ U • PROPOSED o OUTFACE TO EXTEND O / h ����LU y _= 4 O 2.i LOT I '• / ?y 3 g3 -,' STREAM'S BANK/ `v F E-497.30 / GA - 93.40 ��, IGAR=49{Y.67 \ PUBLICDRAINAGE - J� P.� Q I� ' f�FE=495.40 � __-_____ a FFE=491.00 59 \ YD-2 Qlbc - :� , s 28 �r EASEMENT � .:; O.Z` `' " J I \ I Ix PROPOSED VD T STD. ES-1 .........tom 7 �Q X Q J .... R 5 PROPOSED 8" / / zJ I ` I r �' r GAR=485.33 / I S� i / FFE=485.67 LOT PROPOSED SWIM FACILITY &: 494.35 Vey / S D-z / / __�. - 1] / ^ MAINTENANCE EASEMENT O �'H / LJ a9z.as // \ g / / -.. 16 p'.' / 'Og._PG._ Pass / , c9 PROPOSED 3z'PUBLIC- •� DRAINAGE EASEMENT U) LOT ALL DI- i / 1 _ / �j W 18 / . S 1+ 5 / oZ W 17+00 6A / / % 8s m� / ' 83 T 4 per° w w Tc99 ° LOT / / , I 485 BB \ 16+00 44%� 3 i ,�� / Fp� 19 a94.zi • 49z.3 45 as6.o 26 Y �c99 s°6� / = PROPOSED SEGMENTED LOT / RETAINING WALL, Z d / DIAMONDPRID LOT / $3 _L COLOR: BLUE RIDGE 1 / // / / / --II \ / ' 475 B ...GAR 494.83 , , M� .� 11'488.y 468.0 \ 21 IIy�/ FF=495.17 3AR=492.83 w 48967 8 67 4688 4 _ d� / I FFE=493.17 3hill. ,.r R. \ PROPOSED EASEMENT I ' 0 I A DRAINAGE EASEMENT / WIDTH PUB IC LOT D INAGEEASEMENT ' �� 29F 1 28 I DB. PG. LOT LOT, 4 CD \� - LOT LOT LOT LOT �3 - 2z S olJ N ` `.. S.P•BSMT=487.1 II I I I •-• \ //// /\ w225Lu 27 26 .FFE=485.77 OPOSED FFE 496.33 FFE 496.33 BSMT=486.43 dF FFE=497.0 FFE=497.0 BSMT-486.43BST=486.43 / BM.1 23 JOB NO. --80 /� PROPOSED VDOT STD. ES-1 _ = / `? SWIM FACILITY. SEE WPO - --� - - �l- - - / 202194 zozoaoF AMENDMENT#z g - e _ //__V - a� FOR DETAILS. / . `� �� >a GRAPHIC SCALE �4� - - ��p �' SCALE - � 4 1+75 / TG.�� � j � � � � �� � 30 � 0 15� 30 60 120 1 - 30 8C>--0+00 4 1+00 6 -- -- \ \ I COW BRANCH STREAM �J / / // ° u. zz ROP SED DQT PROP $ED z PROPOSED z5 - WALL D - STA.D+00. - - / I O / '\� / / `. SHEET N0. PU DRAINAGE BENEATH PRIVATE ACCESS5 - �PR�POSEV OT STD. ES 1 3. F pnnF� - 483 TW :< / IN FEET ��j onnn mni nic S`Jn P p p EMn PROPOSPD8 HDR - G, 475 BW �\\ ) o NT_-_...._LTIOJ>�A IOFf-DRAINS S�tly EN9` 4778E ------ / I I / / / \ 1 inch = 30 ft. O `El _p4GDB G.� LOCATED WITHIN PRIVATE D PG:_ lO- \ C11i // 499 4941 7/6/22 LO 12 /WALI Lu ��| | | | | | | \n�w^/�r|�—/`^{>/ Design Year: 10 Project: Galaxie Farm Job 4: 202194 Prepared by: FGM, PE INLET STATION OUTLETWATER SURFACE ELEV Do Qa ZW Sf, Hf JUNCTION LOSS FINAL H INLET WATER SURFACE ELEV. RIM ELEV V. Ho QIN VIN Q;*V; V; /2g H; ANGLE Ho Hr 1.3H7 .SHr 487.53 75.00 8.00 0.46 0.00 0.09 8.11 0.26 CO-J 0.46 5.15 2.37 0.41 0.14 167.00 0.29 0.69 0.89 N/A 0.99 488.52 501.33 496.28 77.00 8.00 0.46 0.00 0.10 5.15 0.10 YD4I 0.00 167.00 0.00 0.10 0.13 N/A 0.23 496.51 499.75 484.03 36.98 8.00 0.30 0.00 0.02 3.51 0.05 R175 0.30 2.36 0.71 0.09 0.03 167.00 0.06 0.14 0.18 N/A 0.20 484.23 490.50 484.61 103.89 8.00 0.30 0.00 0.05 2.36 0.02 RF5A 0.00 166.00 0.00 0.02 0.03 N/A 0.08 484.70 490.50 484.53 1 29.44 8.00 0.23 0.00 1 0.01 5.45 0.12 R174 0.12 3.03 0.36 0.14 0.05 139.00 0.10 0.27 0.34 N/A 0.35 484.89 488.00 486.53 95.33 8.00 0.12 0.00 0.01 3.03 0.04 RF4A 1 10.00 133.00 1 0.00 10.04 0.05 1 N/A 0.05 486.59 489.50 484.81 64.79 12.00 1.04 0.00 0.05 3.21 0.04 RFl 0.75 2.93 2.19 0.13 0.05 127.00 0.09 0.18 0.23 N/A 0.28 485.09 489.48 485.13 107.73 12.00 0.75 0.00 0.04 2.93 0.03 RF1A 0.75 2.93 2.19 0.13 0.05 128.00 0.09 0.17 0.23 N/A 0.27 485.40 490.00 485.67 40.54 12.00 0.75 0.00 0.02 2.93 0.03 RF1B 0.75 2.93 2.19 0.13 0.05 116.00 0.09 0.17 0.23 N/A 0.24 485.91 488.50 485.91 68.34 12.00 035 0.00 0.03 2.93 0.03 YDIC 0.48 4.75 2.28 0.35 0.12 111.00 025 040 0.52 N/A 055 486.46 488.25 486.46 47.85 12.00 0.48 0.00 0.01 4.75 0.09 YD1D 0.13 3.20 0.43 0.16 0.06 167.00 0.11 0.25 0.33 N/A 0.34 486.80 488.75 487.55 99.37 12.00 0.13 0.00 0.00 3.20 10.041 YD1E 0.00 171.00 0.00 0.04 0.05 N/A 0.05 487.60 491.75 488.05 29.79 12.00 1.20 0.00 0.03 3.35 0.04 RF6 1.20 3.35 4.02 0.17 0.06 134.00 0.12 0.23 0.29 N/A 0.32 488.37 491.50 488.37 71.34 12.00 1.20 0.00 0.07 3.35 0.04 R176A 1.20 3.35 4.02 0.17 0.06 138.00 0.12 0.23 0.29 N/A 0.36 488.74 491.67 488.74 45.36 12.00 1.20 0.00 0.04 3.35 0.04 YD-513 0.00 144.00 0.00 0.04 0.06 N/A 0.10 488.84 489.75 489.80 33.48 12.00 0.19 0.00 0.00 6.92 0.19 C04F 0.19 3.07 0.57 0.15 0.05 0.00 0.00 0.24 0.31 N/A 0.31 490.11 503.00 496.30 28.62 12.00 0.19 0.00 0.00 3.07 0.04 C04G 0.19 5.97 1.11 0.55 10.19, 0.00 0.00 0.23 0.30 N/A 0.30 496.60 505.75 496.60 60.56 12.00 0.19 0.00 0.00 5.97 0.14 YD4H 0.00 0.00 0.00 0.14 0.18 N/A 0.18 496.78 507.50 486.30 42.12 12.00 0.58 0.00 0.01 6.34 0.16 C04C 0.58 4.74 2.76 0.35 0.12 0.00 0.00 0.28 036 N/A 0.37 486.67 1 491.75 488.55 53.91 12.00 0.58 0.00 0.01 4.74 0.09 YD4D 1 0.19 6.92 1.29 0.74 0.26 0.00 0.00 0.35 0.45 N/A 0.46 489.01 492.00 489.80 30.88 12.00 0.25 0.00 0.00 3.59 0.05 YD4E 0.00 0.00 0.00 0.05 0.06 N/A 0.07 489.87 492.67 489.55 52.00 12.00 0.19 0.00 0.00 2.49 0.02 YD413 0.00 0.00 0.00 0.02 0.03 N/A 0.03 489.58 492.25 486.80 94.18 12.00 0.69 0.00 0.03 5.32 0.11 YD4 0.19 2.49 0.47 0.10 0.03 90.00 0.07 0.21 0.27 N/A 0.30 487.10 492.00 489.55 52.00 12.00 0.19 0.00 0.00 2.49 0.02 YD4A 0.00 0.00 0.00 0.02 0.03 N/A 0.03 489.58 492.25 495.05 98.00 12.00 2.50 0.00 0.41 7.69 0.23 YD3 2.36 9.18 21.67 1.31 0.46 91.00 0.92 1.60 2.08 N/A 2.50 497.55 500.00 497.80 47.46 12.00 2.36 0.00 0.18 9.18 0.33 YD3A 1.86 9.59 17.81 1.43 0.50 90.00 1.00 1.83 2.37 N/A 2.55 500.35 502.33 500.35 90.19 12.00 1.86 0.00 0.21 9.59 0.36 YD3B 1.35 8.57 11.59 1.14 0.40 178.00 0.80 1.56 2.02 N/A 2.23 502.58 508.25 506.05 124.97 12.00 1.35 0.00 0.15 8.57 0.29 YD3C 0.97 9.01 1 8.70 1.26 10.44 180.00 0.88 1.61 2.09 N/A 2.25 508.30 516.00 513.80 44.98 12.00 0.97 0.00 0.03 9.01 0.32 YD3D 0.79 2.96 2.33 0.14 0.05 157.00 0.10 0.46 0.60 N/A 0.62 514.42 1 520.25 518.05 720.30 12.00 0.79 0.00 0.30 2.96 0.03 YD3E 0.26 3.74 0.96 0.22 0.08 169.00 0.15 0.26 0.34 N/A 0.64 518.69 523.83 521.63 58.07 12.00 0.26 0.00 0.00 3.74 0.05 YD3F 1 0.00 155.00 0.00 0.05 0.07 N/A 0.07 521.70 525.33 480.53 42.00 8.00 0.68 0.00 0.11 4.68 0.09 YD2 0.00 130.00 0.00 0.09 0.11 N/A 0.22 480.76 483.00 497.60 130.60 24.00 4.93 0.00 0.05 14.22 0.78 COIA 4-93 8.04 39.62 1.00 035 0.00 0.00 1.14 L48 N/A 1.53 499.13 516.25 512.70 149.65 24.00 4.93 0.00 0.06 8.04 0.25 YDl 0.00 0.00 0.00 0.25 033 N/A 0.39 513.09 517.67 458.10 20.58 15.00 3.57 0.00 0.06 8.60 0.29 12 L68 5.98 10.05 0.56 019 0.00 0.00 0.48 0.63 031 0.38 458.48 470.75 464.00 35.68 15.00 1.68 0.00 0.02 5.98 0.14 14 0.00 170.00 0.00 0.14 0-18 0.09 0.11 1 464.11 470.75 481.38 28.06 15.00 0.87 0.00 0.00 3A6 0.05 36B 0.23 5.45 L28 0.46 0.16 98.00 0.32 0.53 0.69 0.35 0.35 481.73 487.13 474.78 10T93 18 838 0.006 0.64 10.0 0.4 28 7.2 5.8 41.642 0.5 0.18 97 0.365 0.94 1.22 0.61 1.25 476.03 484.43 478.51 27.84 18 7.19 0.004 0.11 5.8 0.1 30 6.0 T3 43.284 0.8 0.29 90 0.574 0.99 L29 0.64 0.76 479.27 484.43 479.70 30.63 18 5.96 0.003 0.08 7.3 0.2 32 5.7 5.1 29.197 0.4 0.14 111 0.287 0.64 0.83 0.41 0.50 480.20 484.50 480.22 59.13 18 5.68 0.002 0.15 5.1 0.1 34 5.4 5.3 29.135 0.4 0.16 173 0.311 0.57 0.74 0.37 0.52 480.74 485.75 480.74 99.52 18 5.45 0.002 0.23 5.3 0.1 36 4.1 53 23.492 0.5 0.18 149 0.352 0.64 0.83 0.42 0.64 481.38 487.17 481.50 109.54 15 4.13 0.003 0.38 5.7 0.1 38 3.8 5.3 20.283 0.4 0.15 160 0.306 0.58 0.76 0.38 0.76 1 482.26 490.76 482.60 28.96 15 3.82 0.003 0.09 5.3 0.1 38B 3.3 4.9 15.974 0.4 0.13 101 0.256 0.49 0.64 0.32 0.41 483.01 490.76 483.01 35.38 15 3.29 0.002 0.08 4.9 0.1 40 2.8 4.5 12.618 0.3 0.11 118 0.219 0.42 0.55 0.27 0.35 483.36 489.48 483.36 90.53 15 2.81 0.002 0.15 4.5 0.1 42 2.2 4.2 9.2402 0.3 0.10 138 0.191 0.37 0.47 0.24 0.38 483.74 491.03 483.93 144.64 15 2.20 0.001 0.14 4.2 0.1 42B 0.6 6.3 3.6948 0.6 0.22 166 0.436 0.72 0.94 0.47 0.61 484.54 489.85 482.55 27.86 15 1.88 0.001 0.02 5.7 0.1 44B 1.0 3.2 3.3232 0.2 0.06 90 0.112 0.30 0.38 0.19 0.21 482.76 488.76 492.72 27.88 15 0.66 0.000 0.00 2.8 0.0 48B 0.00 93 0 0.03 0.04 0.02 0.02 492.74 498.82 471.85 20.76 24 16.52 0.005 0.09 9.0 0.3 24 16.5 10.1 167.46 1.6 0.56 0 0 0.87 N/A 0.44 0.53 472.38 479.42 472.38 100.72 24 16.52 0.005 0.46 10.1 0.4 26 1 1 1 9.1 9.7 88.775 1.5 0.52 107 1.031 1.95 N/A 0.97 1.43 473.81 486.19 478.70 130.91 18 9.11 0.006 0.84 9.7 0.4 44 7.7 9.8 75.369 1.5 0.53 135 1.051 1.94 2.53 1.26 2.10 480.80 488.77 482.62 68.38 18 7.66 0.005 0.31 9.8 0.4 46 7.1 6.1 43.354 0.6 0.20 175 0.401 0.98 1.27 0.64 0.95 483.57 491.37 485.39 28.35 18 7.14 0.004 0.11 6.1 0.1 46B 5.7 9.5 54.447 1.4 0.49 102 0.986 1.62 2.11 1.05 1.17 486.56 491.55 486.56 189.29 15 5.72 0.007 1.26 9.5 0.4 48 3.2 9.9 31.859 1.5 0.53 96 1.056 1.94 2.52 1.26 2.52 489.08 498.78 493.75 159.34 15 3.23 0.002 0.34 9.9 0.4 50 2.5 4.0 10.02 0.3 0.09 178 0.177 0.64 0.83 0.42 0.76 494.51 507.61 501.76 27.83 15 2.49 0.001 0.04 4.0 0.1 50B 1.9 9.9 18.914 1.5 0.53 94 1.055 1.65 2.14 1.07 1.11 502.87 507.80 502.87 147.76 15 1.92 0.001 0.11 9.9 0.4 52 1.0 3.1 13.12911 0.2 1 0.05 1 94 1 0.106 0.54 0.70 0.35 1--F.4-61 8.90 513.11 27.80 15 1.00 0.000 0.01 1 3.1 0.0 52B I + I 1 10.001 94 1 0 10.041 0.05 1 0.02 1 0.03 1 513.14 1 519.02 PIPE DESIGN n = 0.013 for RCP n = 0.01 for HDPE Pipe Hydrology Pipe 2 c v a v E m_ w NV N U V O) - V C o v E E c o ti w N ® d !J o o c E o 1< fi E >Z v J 7 ❑ LL LL R Pipe run: Sir. 52B -SWM Facility 52B 52 0.30 0.50 0.150 0.150 5.00 6.67 1,00 1.00 51225 512.11 27.8 0.01 0.0050 15 4.95 3.13 0.15 52 50B 0.28 0.50 0,140 0.290 5.15 6.62 0.93 1.92 51201 501.00 147.8 0.01 0.0745 15 19A0 9.85 0.25 50B 50 0.20 0.45 0,090 0.380 5.40 6.54 0.59 2.49 500.90 500.76 27.8 0.01 0.0050 15 4.95 4.03 0.12 50 48 0.26 0.45 0,117 0.497 5.51 6.50 0.76 3.23 500.66 492.75 159.3 0.01 0.0496 15 15.59 9.86 0.27 48 46B 0.26 0.45 0.117 1.261 15.09 4.53 0.53 5.72 4%97 485.50 189.3 0.01 0.0289 15 11.90 9.52 0.33 46B 46 0.31 0.45 0.140 1.590 15.42 4.49 0.63 7.14 484A0 484.19 28.4 0.01 0.0075 18 9.86 6.07 0.08 46 44 0.27 1 0.45 0.122 1,711 15.50 1 4.48 0.54 7.66 483.17 481.42 68.4 0.01 0.0256 1 18 1 18.21 1 9.83 0.12 44 1 26 0.02 1 0.90 0.018 2.042 15.62 4.46 0.08 9.11 480.45 477.50 130.9 0.01 0.0225 18 17.07 9.74 0.22 28 24 0.00 0.90 0.000 3.728 15.84 4.44 0.00 16.52 47227 470.B0 100.7 0.01 0.0168 24 31.58 10.13 0.17 24 SWIM 0.00 0.90 0.000 1 3.726 16.01 4.41 1 0.00 1 16.52 1 470.50 1 470.25 1 20.8 1 0.01 0.0121 24 26.96 8.98 0.04 Pipe run: Sir. 48B - Sir. 48 48B 48 1 0.22 0.45 0.099 1 0.099 1 5.00 1 6.67 1 0.66 1 0.66 1 491.86 1 491.72 1 27.9 1 0.01 1 0.0050 1 15 1 4.95 2.76 1 0.17 Pipe run: Sir. 44B - Sir. 44 44B 1 44 1 0.15 0.65 0.098 1 0.313 1 7.25 1 6.00 1 0.59 1 1.88 1 482.00 1 481.55 1 27.9 1 0.01 1 0.0162 1 15 1 8.91 5.74 1 0.08 Pipe run: Sir. 42B - Sir. 25 42B 42 0.64 0.45 0.288 0.390 8.71 5.65 1.63 2.20 483.83 482.93 144.6 0.01 0.0052 15 5.51 4.20 0.57 42 40 0,02 0.45 0.009 0.509 9.28 5,52 0.05 2.81 48283 482.27 90.5 0,01 0.0062 15 5.51 4.49 0.34 40 38B 0,19 0,50 0,095 0.604 9.62 5,45 0.52 3,29 48217 481,93 35.4 0,01 0,0058 15 5,77 4.85 0,12 38B 38 0.05 0.50 0.025 0.705 9.74 5,42 0,14 3.82 481.83 481.60 29.0 0.01 0.0079 15 6.22 5.30 0.09 38 36 0.13 0.45 0.059 0.764 9.83 5.41 0,32 4.13 481.50 480.50 109.5 0.01 0.0091 15 6.68 5.69 0.32 36 34 0.27 0.45 0.122 1.020 10.15 5.34 0,65 5.45 480.08 479A5 99.5 0.01 0.0053 18 9.03 5.35 0.31 34 32 0.08 0.70 0,058 1 1.076 10A6 1 5.28 0,30 1 5.68 479.35 1 479,02 59.1 1 0.01 a0056 1 18 8.52 5.14 0.19 32 30 0.12 0.50 0,060 1.136 %65 5.24 0,31 5.96 478.92 478.50 30.6 0.01 0,0137 18 13.32 7.27 0.07 30 28 0.16 0.70 0.112 1.374 10.72 5.23 0.59 7.19 477.50 477.31 27.8 0.01 0.0067 18 9.31 5.79 0.08 28 26 0.62 0.50 0.310 1.694 10.80 5.21 1.62 8.78 476.25 473.58 107.9 0.01 0.0247 18 17.88 10.03 0.18 Pipe run: Sir. 36B - Sir. 36 36B 1 36 0.22 0.45 0.099 0.135 5.61 6.47 0.64 0.87 480Al 48020 28.1 0.01 0.0075 15 6.06 3.46 0.14 Pipe run: Sir. 14 - Out 14 1 12 0.28 0.90 0.252 0.252 5.00 6.67 1.68 1.68 463,86 463.00 35.7 0.01 0.0241 15 10.03 5.98 0.10 12 1 OUT 0.62 0.50 0.310 0.562 6.00 6.35 1.97 3.57 457.83 457A0 20.6 0.01 0.0355 15 12.17 8.60 0.04 Pipe run: Yard Drain #1 - Out YDi I C01A 1 6.66 0.20 1.332 1.332 1 23.00 3.70 1 4.93 4.93 514.50 511A0 149.7 0.01 0.0227 1 24 1 36.92 8.04 0.31 C01A I OUT 1 0.00 0.90 0.000 1.332 1 23.31 3.67 1 0.00 4.93 511.00 496.00 130.6 0.01 O. 1149 1 24 1 83.07 14.22 0.15 Pipe run: Yard Drain #2 - Sir. 30 YD2 1 30 1 0.36 0.35 0.126 0.126 10.00 5.37 0.68 0.68 480.75 480.00 42.0 0.01 0.0179 8 1.75 4.68 0.15 Pipe run: Yard Drain #3F - Sir. 48 YD3F YD3E 0.12 0.40 0.048 0.048 10.00 5.37 0.25 0.25 52233 520.83 58.1 0.01 0.0258 12 6.20 3.74 0.26 YD3E YD3D 0.25 0.40 0.100 0.148 10.26 5.32 0.53 0.79 520.83 51T25 720.3 0.01 0.0050 12 2.72 2.96 4.05 YD3D YD3C 0.15 0.40 0.060 0.208 14.31 4.64 0.28 0.97 51T25 513.00 45.0 0.01 0.0945 12 11.86 9.01 0.08 YD3C YD3B 0.21 0.40 0.084 0.292 14,39 4.63 0.39 1.35 513.00 505.25 125.0 0.01 0.0620 12 9.61 8.57 0.24 YD313 YD3A 0.28 0.40 0.112 0.404 14.64 4.60 0.51 1.86 505.25 499.33 90.2 0.01 0.0656 12 9.89 9.59 0.16 YD3A YD3 0.28 0.40 0.112 0.516 14.79 4.57 0,51 2.36 499.33 497,00 47.5 0.01 0.0491 12 8.55 9.18 0.09 YD3 48 0.08 0.40 0.032 0.548 14.88 4,56 0,15 2.50 497.00 494.25 98.0 0.01 0.0281 12 6.47 7.69 0.21 Pipe run: Yard Drain #4A - Sir. 42 YD4A YD4 0.06 0.50 0,030 0.030 6.00 1 6,35 0.19 0.19 489.25 1 488.75 52.0 0.01 1 0.0095 12 1 3.78 2.49 0.35 YD4 42 0.10 0.50 0.050 0.110 6.35 1 6.25 0,31 0.69 488.75 1 486,00 94.2 0.01 1 0.0292 12 1 6.60 5.32 0.30 Pipe run: Yard Drain #413 -Yard Drain #4 YD4B YD4 0.08 0.50 0.030 0.030 8.00 8.35 0.19 0.19 489.25 466.75 52.0 0.01 0.0096 12 3.78 2.49 0.35 Pipe run: Yard Drain #4E - Sir. 42B YD4E YD4D 0.08 0.50 0,040 0.040 1 6.00 1 6.35 1 0.25 0.25 489.67 489.00 30.9 0.01 1 0.0217 1 12 1 5,69 3.59 0.14 YD4D C04C 0.06 0.50 0.030 0.102 1 8.41 1 5.72 1 0.17 0.58 489.00 487.75 53.9 0.01 1 0.0232 1 12 5.88 4.74 0.19 C04C 42B 0.00 0.90 0.000 0.102 1 8.59 1 5.67 1 0.00 0.58 487.75 485.50 1 42.1 0.01 1 0.0534 1 12 8.92 6.34 0.11 Pipe run: Yard Drain #4H -Yard Drain #4D YD41-1 C04G 0.08 0.40 0.032 0.032 1 8.00 1 5.81 1 0.19 0.19 495.75 487.00 1 60.6 0.01 1 0.1445 1 12 14.67 1 5.97 0.17 C04G C04F 0.00 0.90 0.000 0.032 8.17 5.77 0.00 0.19 496.00 495.50 28.6 0.01 0.0175 12 5.10 3.07 0.16 C04F YD4D 0.00 0.90 0.000 0.032 8.32 5.74 0.00 0.19 495.50 489.00 33.5 0.01 0.1941 12 17.01 6.92 0.08 Pipe run: Yard Drain #513 - Str. 46B YD-513 RF6A 0.42 0.45 0.189 0.189 6.00 6.35 1.20 1.20 487.99 487.76 45.4 0.01 0.0050 12 2.73 3.35 0.23 RFBA RF6 0,00 0,90 0,000 0,189 6.23 6,28 0.00 1.20 48T76 487,40 71.3 0,01 0,0050 12 2,73 3,35 0,35 RF6 46B 0,00 0,90 0,000 1 0,189 6,58 6,18 0,00 1 1,20 48T40 487,25 29.8 1 0,01 0,0050 12 2,73 3,35 0,15 Pipe run: Yard Drain #lE - Sir. 44B YD1E YDiD 0.04 0.50 0.020 0.020 5.00 6.67 0.13 0.13 489.75 486.75 99.4 0.01 0.0302 12 6.71 3.20 0.52 YDiD YDiC 0.09 0.60 0.054 0.074 5.52 6.50 0.35 0.48 486.75 485.41 47.9 0.01 0.0280 12 6.46 4.75 0.17 YDiC RF113 0.07 0.60 0,042 0.116 5.68 5A5 0.27 0.75 485Al 485.07 68.3 0.01 0.0050 12 2.73 2.93 0.39 RFiB RF1A 0.00 0.90 0,000 0.116 6.07 6.33 0.00 0.75 485.07 484.87 40.5 0.01 a0050 12 2.73 2.93 0.23 RRA RF1 0.00 0.90 0.000 0.116 6.30 6.26 0.00 0.75 484.87 484.33 107.7 0.01 0.0050 12 2.73 2.93 0.61 RF1 44B 0.06 0.90 0.054 0.170 6.92 6.09 0.33 1.04 484.33 484.01 64.8 0.01 0.0050 12 2.73 3.21 0.34 Pipe run: Yard Drain #4A - Sir. 36B RF4A RF4 0.02 0.90 0.018 1 0.018 5.00 6.67 0.12 1 0.12 1 488.00 1 488.00 1 95.3 1 0.01 1 0.0210 8 1 1.90 3.03 1 0.52 RF4 36B 0.02 0.90 0.018 1 0.036 5.52 6.50 0.12 1 0.23 1 486.00 1 484.00 1 29.4 1 0.01 1 0.0879 8 1 3.41 5.45 1 0.09 Pipe run: Yard Drain #5A - Sir. 44B RFSA RF5 0.05 0.90 0.045 1 0.045 1 5.00 1 6.67 1 0.30 1 0.30 1 484.60 1 484.08 1 103.9 1 0.01 1 0.0050 1 8 1 0.93 1 2.36 1 0.73 RF5 44B 0.00 0.90 0.000 1 0.045 1 5.73 1 6.43 1 0.00 1 0.30 1 484.08 1 483.50 1 37.0 1 0.01 1 0.0157 1 8 1 1.64 1 3.51 1 0.18 Pipe run: Yard Drain #41 - Sir. 38B YD41 C0.1 0.19 0.40 0.076 0.976 1 7.00 1 G.. 1 0.46 1 0.48 1 498.25 1 495,75 1 77.0 1 0.01 1 0.0325 8 1 2.38 1 5.15 1 0.25 COJ 38B 0.00 0.90 0.000 0.076 1 7.25 1 6.00 1 0.00 1 0.46 1 495.75 1 487.00 1 75.0 1 0.01 1 0.1167 8 1 4.47 1 8.11 1 0.15 IN SUMP, DESIGN (CURB SPREAD AND INLET SPREAD AND DEPTH) 4.00 (Intensity is 4 inlhr for spread, and 6.5 in/hr for capacity and depth) s Coefficient. n is 0.013 Z, O P d O> ti o'- co ❑ q Q U U Or fad' 6 0 o m w 3 0 o v M _ `v v d iu u .5 w _ N N 3 N N F W N l M v c a - = E a a F K Left 0.12 0.70 0.084 0.34 1.11 1.34 0.005 0.020 2 0.083 4.1500 5.05 0.88 Right 0.03 0.70 0.021 0.08 0.00 0.08 0.005 0.020 2 0.083 4.1500 3.00 0.99 STR 8 DI-3C 6.0 combined flow 0.42 0.07 0.155 3.56 Left 0.49 1 0.62 0.304 1.22 0.00 1.22 0.005 0.020 2 0.083 4.1500 8.17 0.65 Right 0.13 0.82 0.081 0.32 0.00 0.32 0.005 0.020 2 0.083 4.1500 4.97 0.88 STR 12 DI-3C 8.0 combined flow 1.5 0.15 1 0.326 7.46 Left 0c9 0.90 0.081 0.32 0.00 0.32 0.005 0.020 2 0.083 4.1500 4.98 0.88 Right 0.19 0.90 0.171 0.68 0.00 0.68 0.005 0.020 2 0.083 4.1500 a W 0.77 STR 14 DI-3C 8.0 combined flow 1.0 0.11 0.246 T 5.63 Left 0.06 1 0.90 1 0.054 0.22 0.00 0.22 0.005 0.020 2 0,083 4,1500 4,27 0.94 Right 0.04 0.90 0,036 0.14 0.00 0,14 0.005 0,020 2 0,083 4,1500 3,67 0,97 STR 18 DI-3C 6.0 combined flow 0.4 0.06 0.140 3.21 LeR 0.25 0.50 0.125 0.50 0.00 0.005 0.020 2 0.083 4.1500 5.86 0.83 Right 0.37 0.50 0.185 0.74 0.00 0.005 0.020 2 0.083 4.1500 6.78 0.75 STR 28 DI-3C 8.0 combined flow 0.13 0.262 646 Left 0.14 0.70 0.098 0.39 0.00 r0.50 0.005 0.020 2 0.083 4.1500 5.35 0.w Righ[ 0.02 0.70 0.014 0.06 0.00 0.005 0.020 2 0.083 4.1500 258 0.99 STR 30 DI-3C 6.0 combined flowLeR 0.11 0.45 0.050 0.20 0.00 0.005 0.020 2 0.083 4.1500 4.14 0.94 Right 0.18 0.45 0.072 0.29 0.00 0.29 0.005 0.020 2 0.083 4,1500 4.76 0.90 STR 36 DI-3C 6.0 combined flow 0.5 CiAl 0.238 0.22 LeR 0.15 0.50 0.075 0.30 0.00 0.30 0.005 0.020 2 0.083 4.1500 4.64 0.89 Right 0.14 0.50 0.070 0.28 0.00 0.28 0.005 ME 2 0.083 4.1500 4.71 0.89 STR 40 DI-3C 8.0 combined flow 0.6 0.09 0.193 4.42 LeR 0.37 0.45 0.167 0.67 0.00 0.67 0.005 0.020 2 0.083 4.1500 6.52 0.78 Right 0.27 0.45 0.122 0.49 0.00 0.49 0.005 0.020 2 0.083 4.1500 5.79 0.84 STR 42B DI-3C 8.0 combined flow 1.2 0.12 0.269 6,15 All 0.16 0.65 0.104 0.42 1 0.00 0.42 0.005 1 0.020 2 0.083 4.1500 5.47 0.86 STR 2213 DI-3B 8.0 combined flow 0.4 0A0 0.211 L84 INLETS IN SUMP, DESIGN (CURB SPREAD AND INLET SPREAD AND DEPTH) Intensity 6.50 (Intensity is 4 inlhr for spread, and 6.5 in/hr for capacity and depth) Manninas Coefficient. n is 0.013 i 3 r0 -- $ G ffi u v M y. 15 � ~O o o m ` g 'w- 5 w v w v c m 0 d > J Q U U Of O 6 N W v a h Left 0.12 0.70 0.084 0.55 0.00 0.55 0.005 0.020 2 0.083 4.1500 8.05 0.82 Right 0.03 0.70 0.021 0.14 0.00 0.14 0.005 0.020 2 0.083 4.1500 3.60 0.98 STR8 DI-3C 6.0 combined flow 0.68 0,10 0.215 4.92 Left 1 0.49 1 0.62 10.304 1.97 0.00 1.97 0,005 0.020 2 0.083 4.1500 9.80 0.59 Right 0.13 OM0.081 0.52 0.00 0.52 0.005 0.020 2 0.083 4.1500 5.96 0.83 STR 12 DI-3C 8.0 combined flow 2.5 0.21 0.450 10.31 Left 0.09 0.90 0.081 0.53 0.00 0.53 0,005 0.020 2 0,083 4.1500 5.97 0.81 Right 0.19 0.90 0.171 1.11 0.00 I'll 0.005 0.0201 2 0.083 4.1500 7.90 0.67 STR 14 DI-3C 8.0 combined flow 1.6 0.16 0.340 7.78 Left 0,06 0.90 1 0.054 0.35 0.00 0.35 0.005 0.020 2 0.083 4.1500 0,88 Right 0.04 0.90 0.036 0.23 0.00 0.23 0.005 0.020 2 0.083 4.1500 1 4.41 0.92 STR 18 r DI-3C 6.0 combined flow 0.6 0.09 0.194 1 4.44 Le' 0.25 0.50 0.125 0.81 0.00 0.81 0.005 0.020 2 0.083 4.1500 7.03 0.74 Right 0.37 0.50 0.1145 1.20 0.00 1.20 0.005 0.020 2 0.083 4.1500 8.14 1 0.67 STR 28 DI-3C 8.0 combined flow 2.0 0.18 0.390 8.93 Left 1 0.14 10.70 10.098 1 0.64 1 0.00 0.64 0.005 0.020 2 0.083 4.1500 6.41 1 0.78 Right 0.02 0.70 10.0141 0,09 1 0,00 0.09 0.005 0.020 2 0.083 4.1500 3.09 1 0.99 STR 30 DI-3C 6.0 combined flow 0.7 0.10 0.224 5.14 LeR 0.11 0.45 0.050 0.32 0.00 0.32 0.005 0.020 2 0.083 4.1500 4.96 0.88 Righ[ 0.18 0.45 0.072 0.47 0.00 0.47 0.005 0.020 2 0.083 4.1500 5.71 0.84 STR 36 DI-3C 6.0 combined flow 0.8 CiAl 0.236 0.22 Left 1 0.15 1 0.50 10.075 0.49 1 0.00 0.49 0.005 0.020 2 0.083 4.15W 5.60 0.83 Right 1 0.14 1 0.50 10.070 1i 0,48 1 0,00 0.46 0.005 0.020 2 0.083 4.1500 1 0.84 STR 40 DI-3C 6.0 combined flow 0.9 0.12 0.266 6.11 Left 1 0.37 1 0.45 10.167 1.08 0.00 1.08 0.005 0.020 2 0.083 4.1500 7.82 0.71 Right 1 0.27 1 0.45 10.122 0.79 0.00 0.79 0.005 0.020 1 2 0.083 4.1500 6.95 0.75 STR 42B DI-3C 8.0 combined flow 1.9 0.17 0.371 8,51 All 0.16 0.65 0.104 0.68 0.00 0.68 0.005 0.020 2 0.083 4.1500 6.56 0.79 STR 22B FDI-3B 8.0 combined Aow I 0.13 0.292 1 8.69 INLETS ON GRADE, DESIGN (CURB SPREAD AND INLET CAPTURE) INLETS ON GRADE, DESIGN (CURB SPREAD AND INLET CAPTURE) Intensity 4.00 (Intensity is 4 in/hr for spread, and 6.5 in/hr for capacity and depth) Intensity 6.50 (Intensity is 4 in/hr for spread, and 6.5 in/hr for capacity and depth) Mannings Coefficient, n is 0.013 Mannings Coefficient, n is 0.013 Inlet Hydrology Curb and Gutter Inlet Inlet Hydrology Curb and Gutter Inlet 3 3 v g v .R '° �' o a m g o g - a C O L M N ^ N MIle C p 11 w p N C w L y� O V $ X W O C U N C y� L `� N JO N C M L O V 3 X W L U N C 15 3 $ o V M b u! 3 d p? TO 6 m w o > ; a U a_ -' C n ❑ o C C N N N w N (n 4 N > O Y J� ❑ f0 C C `m N N %S ♦ _ d j y ti 'm ° jp o M .-. - w x ¢ o >i II inn d m U i m F o m a 3 U 15 ? c Ol x 6- o r3 M O3 V ° `m O O (n w c J C E C L 2 O « Ol q w r= J - C C T p ¢ 2i v w _ ¢ a m _ a v d > J d U U O O O W r/i W rn H W m on U J J W O O d > J d U U O O O t/J N ti W m N N J J W O O U ¢ 18B 313 4.0 0.04 0.90 0.036 0.14 0,00 0.14 0.005 0.02 2 1 0.083 1 4.1500 1 3.67 0.92 3.5120 0.1463 0.1546 2.10 1.90 1.00 0.14 0.00 - 18B 3B 4.0 0.04 0.90 0.036 0.23 0.00 0.23 0.005 0.02 2 0.083 4.1500 4.41 0.92 3.5120 0.1463 0.1546 2.58 1.55 1.00 0.23 0.00 - 20 313 6.0 0.08 0.60 0.048 0.19 0,00 0,19 0.025 0.02 2 0.083 4.1500 3.02 0.99 3.5120 0.1463 0.1649 3.71 1.62 1.00 0.19 0.00 - 20 38 6.0 0.08 0.60 0.048 0.31 0.00 0.31 0.025 0.02 2 0.083 4.1500 3.62 0.97 3.5120 0.1463 0.1619 4.60 1.30 1.00 0.31 0.00 - 22B 313 8.0 0.19 0.75 0.143 0.57 0,00 0.57 0.020 0.02 2 0.083 4.1500 4.74 0,90 3.5120 0.1463 0.1517 5.74 1.39 1.00 0.57 0.00 - 22B 3B 8.0 0.19 0.75 0.143 0.93 0.00 0.93 0.020 0.02 2 0.083 4.1500 5.69 0.84 3.5120 0.1463 0.1429 7.30 1.10 1.00 0.93 0.00 _ 32 313 A0 0.12 0.50 0.060 0.24 0,00 0,24 0.005 0.02 2 0.083 4.1500 4A5 0.88 3.5120 0.1463 0.1488 2a6 1.50 1.00 0.24 0.00 - 32 3B 4.0 0.12 0.50 0.060 0.39 0.00 0.39 0.005 0.02 2 0.083 4.1500 5.34 0.88 3.5120 0.1463 0.1466 3.27 1.22 1.00 0.39 0.00 _ 34 313 6.0 0.08 0.70 0.056 0.22 0.00 0.22 0.020 0.02 2 0.083 4.1500 3.34 0,95 3.5120 0.1463 0.1590 3.77 1.59 1.00 0.22 0.00 - 34 38 6.0 0.08 0.70 0.056 0.36 0.00 0.36 0.020 0.02 2 0.083 4.1500 4.01 0.95 3.5120 0.1463 0.1590 4.62 1.30 1.00 0.36 0.00 - 36B 313 6.0 0.22 0.45 0.099 0.40 0.00 0.40 0.005 0.02 2 0.083 4.1500 5.37 0,79 3.5120 0.1463 0.1356 3.48 1.73 1.00 0.40 0.00 - 36B 38 313 313 6.0 6.0 0.22 0.13 0.45 0.45 0.099 0.059 0.64 0.38 0.00 0.00 0.64 0.38 0.005 0.049 0.02 0.02 2 2 0.083 0.083 4.1500 4.1500 6.44 3.44 0.79 0.98 3.5120 3.5120 0.1463 0.1463 0.1356 0.1634 4.26 6.06 1.41 0.99 1.00 1.00 0.64 0.38 0.00 0.00 - - 38 313 6.0 0.13 0,45 0.059 0.23 0,00 0,23 0.049 0.02 2 0.083 4.1500 2.87 0.98 3.5120 0.1463 0.1634 4.94 1.21 1.00 D23 D00 - 38B 313 6.0 0.05 0.50 0.025 0.10 0.00 0.10 0.049 0.02 2 0.083 4.1500 2.09 0,99 3.5120 0.1463 0.1649 3.44 1.74 1.00 0.10 0.00 - 38B 42 313 1 313 6.0 4.0 0.05 1 0.02 0.50 1 0,45 0.025 0.009 0.16 0.06 0.00 0,00 0.16 0.06 0.049 0.005 0.02 1 0.02 2 2 0.083 0.083 4.1500 4.1500 2.50 2.62 0.99 0.99 3.5120 3.5120 0.1463 0.1463 0,1649 0,1649 4.22 1,38 1.42 2,89 1.00 1.00 0.16 0.06 0.00 0.00 - - 42 313 4.0 0.02 1 0.45 0.009 0.04 0.00 1 0.04 0.005 1 0.02 2 0.083 4.1500 2.18 0.99 3.5120 1 0.1463 0.1649 1.13 3.54 1 1.00 0.04 0.00 - 44 313 4.0 0.02 0.90 0.018 0.07 0.00 0.07 0.037 0.02 2 0.083 4.1500 1.95 1.00 3,5120 0,1463 0.1663 2.74 1.46 1.00 0.07 0.00 - 44 313 4.0 0.02 0.90 0.018 0.12 0.00 0.12 0.037 0.02 2 0.083 4.1500 2.33 1.00 3.5120 0.1463 0.1663 3.36 1.19 1.00 0.12 0.00 - 448 38 8.0 0.17 0.65 0.111 0.44 0.08 0.52 0.037 0.02 2 0.083 4.1500 4.08 0.90 3.5120 0.1463 0.1517 6.63 1.21 1.00 0.44 0.00 - 44B 3B 8.0 0.17 0.65 0.111 0.72 0,27 0.99 0.037 0.02 2 0.083 4.1500 5A9 0.90 3.5120 0.1463 0,1517 8,69 0,92 1.00 0.72 0.00 - 46 38 8.0 0.27 0.45 0.122 0.49 0.00 0.49 0.038 0.02 2 0.083 4.1500 3.95 0.90 3.5120 0.1463 0.1517 6.51 1.23 1.00 0.49 0.00 - 46 3B 8.0 0.27 0.45 0.122 0.79 0.00 0.79 0.038 0.02 2 0.083 4.1500 4.75 0.90 3.5120 0.1463 0.1517 7.98 1.00 1.00 0.79 0.00 - 46B 3B 6.0 0.31 0.45 0.140 0.56 0.00 0.56 0.038 0.02 2 0.083 4.1500 4A7 0.89 3.5120 0.1463 0.1502 6.94 0.86 1.00 0.56 0.08 44B 46B 3B 6.0 0.31 0.45 0.140 0.91 0.00 0.91 0.038 0.02 2 0.083 4.1500 5.01 0.89 3.5120 0.1463 0A502 8.51 0.71 1.00 0.91 0.27 44B 48 3B 8.0 0.26 0.45 0.117 0.47 0.00 0.47 0.040 0.02 2 0.083 4.1500 3.87 0.90 3.5120 0.1463 0.1517 6.51 1.23 1.00 0.47 0.00 - 48 3B 8.0 0.26 0.45 0.117 0.76 0.00 0.76 0.040 0.02 2 0.083 4.1500 4.64 0.90 3.5120 0.1463 0.1517 T98 1.00 1.00 0.76 0.00 - 48B 3B 8.0 0.22 0,45 0.099 0.40 0,00 0,40 0.040 0.02 2 0.083 4.1500 3.63 0,93 3.5120 0.1463 0,1561 5,96 1,34 1.00 0.40 0.00 - 48B 3B 8.0 0.22 0.45 0.099 0.64 0.01 0.66 0.040 0.02 2 0.083 4.1500 4.40 0.93 3.5120 0.1463 0.1561 7.38 1.08 1.00 0.64 0.00 - 50 3B 10.0 0.26 0.45 0.117 0.47 0,00 0,47 0.071 0.02 2 0.083 4.1500 3.47 0.95 3.5120 0.1463 0,1590 7.51 1.33 1.00 0.47 0.00 - 50 3B 10.0 0.26 0.45 0.117 0.76 0.17 0.93 0.071 0.02 2 0.083 4.1500 4.50 0.95 3.5120 0.1463 0A590 10.05 1.00 1.00 0.76 0.00 - 50B 3B 8.0 0.20 0.45 0.090 0.36 0.00 0.36 0.071 0.02 2 0.083 4.1500 3.15 0.96 3.5120 0.1463 0.1605 6.69 1.20 1.00 0.36 0.00 - 50B 3B 8.0 0.20 0.45 0.090 0.59 0.00 0.59 0.071 0.02 2 0.083 4.1500 3.78 0.96 3.5120 0.1463 0.1605 8.21 0.97 1.00 0.59 0.01 48B 52 3B 10.0 0.28 0.50 0.140 0.56 0.00 0.56 0.055 0.02 2 0.083 4.1500 3.90 0.90 3.5120 0.1463 0.1517 T72 1.30 1.00 0.56 0.00 - 52 3B 10.0 0.28 0.50 0.140 0.91 0.00 0.91 0.055 0.02 2 0.083 4.1500 4.68 0.90 3.5120 0.1463 0.1517 9A7 1.06 1.00 0.91 0.00 - 52B 3B 8.0 0.30 0.50 0.150 0.60 0.00 0.60 0.055 0.02 2 0.083 4.1500 4.00 0.90 3.5120 0.1463 0.1517 7.95 1.01 1.00 0.60 0.00 - 52B 3B 8.0 0.30 0.50 0.150 0.98 0.00 0.98 0.055 0.02 2 0.083 4.1500 4.80 0.90 3.5120 0.1463 0.1517 9.74 0.82 1.00 0.98 0.17 50 SCOTT7R. 05-LLINSZI Lic. No. 035791 7/6/22InKTAT �'4' a� 1 N H- Z w Z O O J U �_ a V / U W � co rq Z 0 U U) N Z J O Q 0 F > z a (~ N L9 z W Z 0' [7 N Q LU W N Q z [7 W N a N J Q I..L Z J � LQ > V / rc L9 (n LLJ IZ ' G z - z U 0 w cn z 1-4~ Ul W 0 Z U� D //� V/ W W U� I..L LLI W 0 c�lY/ W LL (Q(r� 1uu-4 `l X O Q o J N 'w-, < w ILL a V) JOB NO. 202194 SCALE N/A SHEET NO. 15 BYPASS STORM SEWER (NOTE: SEE PREVIOUS SHEET FOR INLET THROAT SIZING) �TH 0F� O �C, SCOTT R. LINS�Z Lic. No. 035791,E �0 7/6/22 �4 o��SSIONAL E��1 ' E w z 3 z W z O U 0 0 U c ° _ 3 m a m O 3 o c E2 ` o 0 U 0 0 0 a 0 U 0 a o U > 0 y o a T c o o o N a o n o 0 o n T o F c 0 _z z w z z w z J o y o U X r U 0 o 0 o- ° STRUCTURE DRAIN ,w Vl ZW O u (^ ^�/ H W li z O a V o z O Y) w K k J Q H Z .. F Z W 2 O o 0 2i N m cc w a p Ln w DesignYear: 10 Project: Galaxie Farm Job #: 202194 Prepared FGM, PE OUTLETWATER MEMEJ... JUNCTION LOSS> N N N N N � 6 N W N N W N Z > > J J > cn W O zz Q U Z W W J � Mimi W Q O O N U N z W G zN Wn r Z z Q J a > I O H� \ / 1--II M L.I.J ^ V/ �c L �� X Q -� d (%) z O L r Q 11 O U� W zz9 Q 1 w W JOB NO. 202194 SCALE N/A SHEET N0. 16 AGE DRAINAGE DESCRIPTIONS PIPE INFORMATION INLET INFORMATION STIR. NO. DIA. in. LENGTH* ft. SLOPE % INVERT IN INVERT OUT MATERIAL INLET TYPE Curb T SLOT LENGTH RIM* ELEVATION COMMENTS 52B DI-3B CG-6 8' 519.02 VDOTSTD. IS-1 REO'D 52A 15 27.80 0.50% 512.25 512.11 HDPE 52 DI-3B CG-6 10' 518.90 VDOTSTD. IS-1 REO'D 51 15 147.76 7.45°h 512.01 501.00 HDPE 50B DI-3B CG-6 8' 507.80 VDOTSTD.IS-1 REO'D 50A 15 27.83 0.50°� 500.90 500.76 HDPE 50 DI-3B CG-6 8' 507.61 VDOTSTD.IS-1 REO'D 49 15 159.34 4.96% 500.66 492.75 HDPE 48 DI-3B CG6 8' 498.78 VDOTSTD. IS-1 REO'D 47 15 189.29 2.89% 490.97 485.50 HDPE 46B DI-3B CG-6 6' 491.55 VDOTSTD.IS-1 REO'D 46A 18 28.35 0.75°h 484.40 484.19 HDPE 46 DI-3B CG-6 8' 491.37 VDOTSTD.IS-1 REO'D 45 18 68.38 2.56°� 483.17 481.42 HDPE 44 DI-3B CG6 4' 488.77 VDOTSTD. IS-1 REO'D 43 18 130.91 2.25% 480.45 477.50 HDPE 26 MH-1 - - 486.19 VDOTSTD. IS-1 REO'D 25 24 100.72 1.66% 472.27 470.60 HDPE 24 MH-1 - - 479.42 VDOTSTD.IS-1 REO'D 23 24 20.76 1.21°h 470.50 470.25 HDPE 48B DI-3B CG-6 8' 498.82 VDOTSTD.IS-1 REO'D 48A 15 27.88 0.50°h 491.86 491.72 HDPE 44B DI-3B CG-6 8' 488.76 VDOTSTD.IS-1 REO'D 44A 15 27.86 1.62% 482.00 481.55 HDPE 42B DI-3C CG6 8' 489.85 VDOTSTD. IS-1 REO'D 42A 15 144.64 0.62% 483.83 482.93 HDPE 42 DI-3B CG-6 4' 491.03 VDOTSTD.IS-1 REO'D 41 15 90.53 0.62°h 482.83 482.27 HDPE 40 DI-3C CG-6 6' 489.48 VDOTSTD.IS-1 REO'D 39 15 35.38 0.68°� 482.17 481.93 HDPE 38B DI-3B CG6 6' 490.76 VDOTSTD. IS-1 REO'D 38A 15 28.96 0.79% 481.83 481.60 HDPE 38 DI-3B CG6 6' 490.76 VDOTSTD. IS-1 REO'D 37 15 109.54 0.91% 481.50 480.50 HDPE 36 DI-3C CG-6 6' 487.17 VDOTSTD.IS-1 REO'D 35 18 99.52 0.63°h 480.08 479.45 HDPE 34 DI-3B CG-6 6' 485.75 VDOTSTD.IS-1 REO'D 33 18 59.13 0.56°h 479.35 479.02 HDPE 32 DI-3B CG6 4' 484.50 VDOTSTD. IS-1 REO'D 31 18 30.63 1.37% 478.92 478.50 HDPE 30 DI-3B CG-6 6' 484.43 VDOTSTD. IS-1 REO'D 29 18 27.84 0.67% 477.50 477.31 HDPE 28 DI-3C CG-6 8' 484.43 VDOTSTD.IS-1 REO'D 27 18 107.93 2.47°h 476.25 473.58 HDPE 36B DI-3B CG-6 6' 487.13 VDOTSTD.IS-1 REO'D 36A 15 28.06 0.75°� 480.41 480.20 HDPE 14 DI-3C CG6 8' 470.75 VDOTSTD. IS-1 REO'D 13 15 35.68 2.41% 463.86 463.00 RCP3 12 DI-3C CG-6 8' 470.75 VDOTSTD. IS-1 REO'D 11 15 20.58 3.55% 457.83 457.10 RCP3 YD1 EW-1 - 517.67 YD1-001A 24 149.65 2.27% 514.50 511.10 HDPE C01A Cleanout 24" 516.25 C01A-OUT 24 130.60 11.49% 511.00 496.00 HDPE YD2 Yard Drain Inlet 18" 483.00 YD2-30 8 42.00 1.79°h 480.75 480.00 HDPE YD3F Yard Drain Inlet 18" 525.33 YD3F-YD3E 12 58.07 2.58°h 522.33 520.83 HDPE YD3E Yard Drain Inlet 18" 523.83 YD3D-YD3D 12 720.30 0.50% 520.83 517.25 HDPE YD3D Yard Drain Inlet 18" 520.25 YD3D-YD3C 12 44.98 9.45% 517.25 513.00 HDPE YD3C Yard Drain Inlet 18" 516.00 YD3GYD3B 12 124.97 6.20°h 513.00 505.25 HDPE YD3B Yard Drain Inlet 18" 508.25 YD3B-YD3A 12 90.19 6.56°� 505.25 499.33 HDPE YD3A Yard Drain Inlet 18" 502.33 YD3A-YD3 12 47.46 4.91% 499.33 497.00 HDPE YD3 Yard Drain Inlet 18" 500.00 YD3-48 12 98.00 2.81% 497.00 494.25 HDPE YD4A Yard Drain Inlet 18" 492.25 YD4A-YD4 12 52.00 0.96°h 489.25 488.75 HDPE YD4 Yard Drain Inlet 18" 492.00 YD4-42 12 94.18 2.92°� 488.75 486.00 HDPE YD4B Yard Drain Inlet 18" 492.25 YD4B-YD4 12 52.00 0.96% 489.25 488.75 HDPE YD4E Yard Drain Inlet 18" 492.67 YD4E-YD4D 12 30.88 2.17°h 489.67 489.00 HDPE YD4D Yard Drain Inlet 18" 492.00 YD4D-004C 12 53.91 2.32°h 489.00 487.75 HDPE C04C Cleanout 12" 491.75 C04C-42B 12 42.12 5.34% 487.75 485.50 HDPE YD4H Yard Drain Inlet 18" 507.50 YD4H-004G 12 60.56 14.45% 495.75 487.00 HDPE C04G Cleanout 12" 505.75 C04G-004F 12 28.62 1.75°h 496.00 495.50 HDPE C04F Cleanout 12" 503.00 C04F-YD4D 12 33.48 19.41°h 495.50 489.00 HDPE YD-5B Yard Drain Inlet 18" 489.75 YD5B-RF6A 12 45.36 0.50% 487.99 487.76 HDPE RF6A Cleanout 12" 491.67 RF6A-RF6 12 71.34 0.50% 487.76 487.40 HDPE RF6 Cleanout 12" 491.50 RF6-46B 12 29.79 0.50°h 487.40 487.25 HDPE YD1E Yard Drain Inlet 18" 491.75 YD1E-YD1D 12 99.37 3.02°h 489.75 486.75 HDPE YD1D Yard Drain Inlet 18" 488.75 YD1D-YD1C 12 47.85 2.80% 486.75 485.41 HDPE YD1C Yard Drain Inlet 18" 488.25 YD1C-RF1B 12 68.34 0.50% 485.41 485.07 HDPE RF1B Cleanout 12" 488.50 RF1B-RF1A 12 40.54 0.50°h 485.07 484.87 HDPE RF1A Cleanout 12" 490.00 RF1A-RF1 12 107.73 0.50°h 484.87 484.33 HDPE RF1 Cleanout 12" 489.48 RF1-44B 12 64.79 0.50% 484.33 484.01 HDPE RF4A Cleanout 8" 489.50 RF4A-RF4 8 95.33 2.10% 488.00 486.00 HDPE RF4 Cleanout 8" 488.00 RF4-36B 8 29.44 6.79°h 486.00 484.00 HDPE RF5A Cleanout 8" 490.50 RF5A-RF5 8 103.89 0.50°� 484.60 484.08 HDPE RF5 Cleanout 8" 490.50 RF5-44B 8 36.98 1.57% 484.08 483.50 HDPE YD41 Yard Drain Inlet 18" 499.75 YD41-COJ 8 77.00 3.25% 498.25 495.75 ADS CO-J Cleanout 8" 501.33 COJ-38B 8 75.00 11.67°h 495.75 487.00 ADS PIPE DESIGN n = 0.013 for RCP n = 0.01 for HDPE Pipe Hydrology Pipe � ^ N m a E °. T i° y m m E m `o � c n E E � m m � E _ o o b o r � V ❑ yo_+ C = w m i i E q ❑ _ > v 10 N c W Q Q ¢ e f° ❑ LL > LL K Pipe run: ES-1 -Out ES-1 8 15.80 0.55 8.580 8.580 17.00 4.29 38.83 45.70 484.80 479.50 297.1 0.01 0.0172 30 58.28 13.11 0.38 8 6 0.15 0.70 0.105 8.685 17.36 4.25 0.45 46.15 479.40 475.75 162.0 0.01 0.0225 30 66.65 14.64 0.18 6 4 1.11 0.35 0.389 9.074 17.56 4.23 1.64 47.79 475.65 474.74 51.9 0.01 0.0175 30 58.78 13.32 0.06 4 2 21.60 0.25 5.400 19.663 17.63 4.22 22.79 57.00 474.64 471.30 197.6 0.01 0.0169 30 57.77 13.41 0.25 2 OUT 0.00 0.45 0.000 23.483 17.87 4.19 0.00 77.93 468.80 468.25 36.0 0.01 0.0153 36 89.38 14.24 0.04 Pipe run: Str. 18C - Str. 4 18C 18 20.70 0.25 5.175 5175 15.00 4.55 23.52 23.52 484.50 483.67 38.3 0.01 0.0217 24 36.10 12.18 0.05 18 i6 0.10 0.90 0.090 5.409 15.05 4.54 0.41 24.55 48t89 477.44 161.1 0.01 0.0276 24 40.72 13.47 0.20 i6 4 0.00 0.90 0.000 5.409 15.25 4.51 0.00 24.55 477.34 474.74 138.4 0.01 0.0188 24 33.60 11.65 0.20 Pipe run: Str. 18B- Str. 18 18B 18 0.04 0.90 0.036 0.036 5.00 6.67 0.24 0.24 483.71 481.99 47.9 0.01 0.0359 15 13.26 4.05 0.20 Pipe run: Str. 22B Str. 18 22B 20 0.08 0.75 0.060 0.060 5.00 6.67 0.40 0.40 482.92 482.64 24.7 0.01 0.0114 15 7.47 3.15 0.13 20 18 0.08 0.60 0.048 0.108 5.13 6.62 0.32 0.72 482.54 481.99 61.3 0.01 0.0090 15 6.64 3.52 0.29 ---_-___ 1' 1 �� 1 11 1 11 1 1 1 1 1 1 1 I l l m 1 1 1 1 1 �: 11 ':• 1 1 ---_-__----- 1 1 1 ' I l l 1 1 1 I l l m 1 1 1 1 1 1 ,: •• , '.:®1. ---_-__----- 1 11 11 1 11 �m� 1 • .. ' 1 DRAINAGE DESCRIPTIONS STR. NO. PIPE INFORMATION INLET INFORMATION COMMENTS DIA. in. LENGTH* ft. SLOPE % INVERT IN INVERT OUT MATERIAL INLET TYPE Curb Type RIM* ELEVATION ES-1 ES-1 - 488.50 7 30 297.08 1.72% 484.60 479.50 HDPE 8 DI-3C - 488.13 VDOTSTD. IS-1 REQ'D 7 30 161.95 2.25% 479.40 475.75 HDPE 6 DI-7 - 483.00 VDOTSTD. IS-1 REQ'D 5 30 51.94 1.75% 475.65 474.74 HDPE 4 MH-1 - 484.25 VDOTSTD. IS-1 REQ'D 3 30 197.56 1.69% 474.64 471.30 HDPE 2 MH-1 - 477.00 VDOTSTD. IS-1 REQ'D 1 36 36.02 1.53% 468.80 468.25 HDPE 18C ES-1 - 488.11 VDOTSTD. IS-1 REQ'D 18C-18 24 38.32 2.17% 484.50 483.67 HDPE 18 DI-3C CG-6 488.17 VDOTSTD. IS-1 REQ'D 17 24 161.06 2.76% 481.89 477.44 HDPE 16 MH-1 - 486.17 VDOTSTD. IS-1 REQ'D 15 24 138.38 1.88% 477.34 474.74 HDPE 18B DI-3B CG-6 488.08 VDOTSTD. IS-1 REQ'D 18A 15 47.88 3.59% 483.71 481.99 HDPE 22B DI-36 CG-6 490.00 VDOTSTD. IS-1 REQ'D 22A 15 24.66 1.14% 482.92 482.64 HDPE 20 DI-3B - 489.00 VDOTSTD. IS-1 REQ'D 19 15 61.30 0.90% 482.54 481.99 HDPE