HomeMy WebLinkAboutSDP202100008 Correspondence 2022-08-03 (4)SHIMP ENGINEERING, P.C.
Design Focused Engineering
August 3, 2022
David James
County of Albemarle
Department of Community Development
401 McIntire Road, North Wing
Charlottesville, Virginia 22902
RE: Response Letter #2 for SDP202100008 Proffit Road Townhomes South— Final Site Plan
Dear David,
Thank you for your review of the Final Site Plan for ProfPit Road Townhomes South. This letter contains
responses to County comments dated October 19, 2021 & February 10, 2022. Our responses are as
follows:
Comments dated February 10, 2022:
A. Verify approved drainage inlet map is still correct.
The drainage area map is still correct. Lots 37-40 were originally designed to flow to
structure All while lots 32-36 were originally designed to flow to structure A4
The roof drains that were added still flow to structures All & A4. Below is an image from
the approved VSMP for the Inlet drainage map
A
7
I
.Iy.,e�
ME°
d! i�t�
1
-
-s
b
oQt2
�;
�
i
1i►1
-
1
SHIMP ENGINEERING, P.C.
Design Focused Engineering
B. Include the yard drainage design with the site plan. (8" min for yard drains)
The roof drains are now shown on the final site plan on sheet C6.
Comments dated October 19, 2021
5. Sheet I I— Show station where streets intersect. Rev. 1) partially addressed. Stations are
missing for Road A profile.
The road intersection stations are now shown on the road profiles. Please see Sheet C11.
6. Sheet 12 — Tree near Al2 will need to be moved outside drainage easement. Rev. 1) Please locate
tree near Str. 9A at least 10' away. A small ornamental tree can be substituted in its place if
not able to relocate. Please discuss with planner.
The tree is 6.5 ft away from structure A9. Generally, in a private storm easement, a 5 ft
distance is acceptable between a tree and a storm structure.
8. Easement plat recordation required prior to FSP approval. ( Rev. 1) Comment still applies.
Acknowledged, the plat has been recorded and all easements show instrument number on the
plan.
9. (Rev. 1) Locate sign so that edge of sign is 2' ( min) horz. from FOC.
Comment addressed with road plan submittal.
If you have any questions or concerns about these revisions, please feel free to contact me at
Stephaniekshimp-en ing eering com or by phone at 434-227-5140.
Regards,
Stephanie Paul
Shimp Engineering, P.C.