HomeMy WebLinkAboutSDP202000073 Plan - Revision 2022-08-291/ 7 TIE TO EXI ILITY i...... ........ J /
TO BUILDING \ / CT BANKS
e 7ST \ \ �\� PVC/.... .
^ I 1p OR \ CON /./.'.'.'
TIE TO C� Y \ ' /
8" STUB OUT 8 X6 ti? / eU/�9CCp
\\ REDUCER / NG \ 22.50+450BEND
�o \ Ak 4 ., 6. AfcH LINE
` . �L ...... ....'.'.' \\ TO BUILDING \ \ \ 6r P-443+ �[ \ \ /
\\ nk �I
\\ / E
TIE TO EXI I -1 IT THIS SHEET \ AGES \
\ / IT BANKS \ `\\ \ �\ APL�
CH. 40
a \
22.5°+450BEND o \\ \---'UGP/ \`� \ s • REFER TO PLAN TITLED "KESWICK HALL ADDITIONS AND
\ AfCHLIN S\ P443+ / \� Box (2) 4"/SCH. 40 PVC i \ S TP= �\ SITE IMPROVEMENTS" SDP-2018-016, WP0201800020 & �\
fr lRR/ I CONDUITS \\ END
J�SSH T c� �\ ERD PE, (PROVIDETRACER WIRE) \� WP0201800078 FOR DESIGN INFORMATION. `
BEND / D RAIL, STEPS STA R2' \ p\ \
HANDRAIL \ U \ \
RISERS S \ \
h \ \ \\ \ \ 6F WOOD DECK GCT l Gcr\ TFMR
C' \
(7) WOOD \ \ \
........ \ STEPS
SANITARYMH \
........\....
\ )U\G ?G T\ /IRRIGATION \ EOMl ° BE v \
\ \
\ KESWICK HALL
TOP=435.65 2.5
......\ UClNV 1N=427.76 P ''''''' Y T 'WVOUT=42702 ....GRAAIRS WITH' GUEST WINGm(SEE SHEET C1.1) �i. 2'X2, O/ M �" ' \
(( RISERS � \
COMMUNICATIONS \ cr !yC SEE�DETAIL. \ \ \ \
YBALL / \ P MANHOLE.
/\ \emBUMPs
ERBLOCK �q/.. \� \ \ '\ 6' WID \ \ \ \ \ \
SL vy (TYP)_ _ - 6„ CLASS 52 DIP1!\
O ` RV �(TYP.)� R5' ROSSWALK \\ <
BUILDING �
/ \ ® �x a \ T
24' R5' 10 R54' \ �\ G,OZC\�R25'
\ \
9' v (2) ELECTRIC Gib plc P \ TACTILE \ \ s
p
011
R10' EP R191.38' (Tyr.) VEHICLE \L� �iZTF \ F\DOMES \ \ SAN
RELOCATED R10' CHARGING c C
(2) 4" SCH. 40 PVC CONDUITS \ \ ' �TA�ONS RELOCATE \ Le STOP
25 c\ \\
1 \ (ENCASED IN CONCRETE) UTILITY LINES SIGN
LAY/PMENTD R217. \ \ . R43' (SEE NOTE #1) 24' \ \ \
1 / WIDE \
\ \ 11.25° BEND C SS LK �e \ 6 , KESWICK ESTATES GATE
5' R81.14' \ 5 \ \ IMPROVEMENTS. CONTRACTOR TO
— / y
R81.14 COORDINATE WITH KESWICK
j 4' I yy/4D NDRAIL d \ ESTATES CONTRACTOR FOR
P R�0' SECURITY EQUIPMENT PLACEMEN-
\ HEAVY DUTY 3' 2 CUB CURB WIDE STOP 25 O TRANSITIOIT \ / � \ (BY OTHERS -SEE NOTE #4) (SEE
J WOOD GAZEBO S RRAAA RO 1 SAL LANDSCAPE PLANS
\ CONCRETE a. T NSITION _ TRANSITION \ SIGN )q, RELOCATE
l� _
CG.6 SAN R14' U I ILI I Y LINES
B/ /
92 EXTEND REINFORCED R124' CG- (SEE NOTE #1)
TURF TO EDGE S 3 �0 5' (2) ELEC X \
I \ OF PAVEMENT 24, VEHICLE
\ 6, R124.08' \ R� CHARGING \ \ \
STATIONS \ / i
° I C \ \ REINFORCED C
R130' CG-2 io \
TURF PAVERS .
\ I 2 2" PVC
I y FOUNTAIN 11'
L WPO BUFFER RPA \ \ ` \ OUTLET ❑; 6 GG T \ \ S \
\ OX
ASPHALT
AD GNS9'
\�
cp„ CCESSIBL \ \ v sy2 PROPOSED HARDSCAPE. FOUNTAIN
SEE LANDSCAPE PLAN FDC
(SEES1.0) C ... .'u d
R10' co '1\' C' ' • '
(6) 5" SCH-40 PVC CONDUITS FOR POWER SERVICE
(SEE ELECTRICAL DRAWINGS FOR FINAL CG-2 \
IRRIG REQUIREMENTS) 18' 9' P 1 \ \ c
oIV
(4) RISERS WITH CG 6 ITY1 CATE ° o \
\ 1 HANDRAIL ) ILI LINES
\ (SEE ARCH. PLANS) R8 \ TE #1) \
A� GENERATOR PAD o \ L \ \ \
\ r 24' EMERGENCY (HEAVY DUTY CONC.
\ 2X2 H- ACCESS PATH SEE ARCH. PLANS) 5.55'
COMMUNICATIONS LOADING DOCK 3.7' 5.55' \ o TS&V
MANHOLE. I co PROPOSED (SEE ARCH. PLANS) 15' ' 22 4 5' R22' 22, RS' \ G
\ SPA DUMP TER (10.67X16) 29.5' (7CURB�RDS \ GG L R5 \
\ Rp9 ¢ LOADING AREA p TRANSITION �\ \
I (22'X29.5') R44' D
REVISED 20' PERMANENT 0
\ STORMWATER SIDEWALK WITH HANDRAIL 5' 24 \ \ \
EASEMENT MANAGEMENT FACILITY (SEE ARCH. PLANS) � G / G CG-3 \ \
45° BEND \
\ DB 05368 PG 06113-00619 STAIRS s
. F
(SEE ARCH. PLANS) CRI ICAL STEEP G \ \
\ I (2) 4 SCH. 40 PVC 17.33X6' MECHANICAL EQUIPMENT PAD S OPES (TYP.) G
\ CONDUITS (HEAVY DUTY CONC. - SEE ARCH. PLANS) 5.79' \�
\ I (PROVIDE TRACER WIRE) 6, \ 2'X2' COMMUNICATIONS p
MANHOLE. \ \ \ \O
\ 9\ 3" DOMESTIC SERVICE
6" FIRE SERVICE UGP / \ \
Cl
\ C2 45° 3" C900 PVC\ \ \
\ I BEND / STONE SLAB STEPS a \ \
\ @ (NON -EGRESS PATH)
\ \ SAN F / GAS METER \
\ IE BUILDING SANITARY I (SEE NOTE 3) I \
y \ TO FXISTING LINE. SEE Aa 6" CLASS-52
/ �' l�
STANDARD ACSA SEWER I D .DE_ /
W \ SERXCE LATERAL / (= 5° BENDS \
CONNECTIQN DETAIL. _
y y y y\ WETLANDS \\
y \11 ,y ,y y y ' , y � � \ W O BUFFER � � � � � � D / 450 BEND \\
14/ y � y y 14/ 14/ �
C3
y y y y \ y y y I \
w
50' WPO v
41 y y � \y y y BUFFER / \
y y SETBACK \
� A/ A/ � y y y
\41 � 11,
y y y
y y y Z \ n
ILI
z
q� ..... .....p
.... U
U CRAIG W. 7. KOTARSK1
CRITICAL Lic. No. 0402048507
SLOPES (TYR) a 11-12 -21
O S"LORTAL
\ \ Mo E
..... .. ... ... N O
\ E
\ E
Lu
/ ¢LL c 3
/ o
Lu O o
/ d' W L M
J uco
L6
d i p N
/ CJFWF N�
F � � Z
�pcoxx O
... y ::.::........ / U) _ N m
u
r4
/ ... .... / d C)
\/ C) w
\
J / ~ W
/ . . 0
O
O
4CK G� f , o " W W
0 Ln
.., OW�W
40 ps- o
A w
•FP�R / u LU C
O N ti O
O \G / /Tl// � ti000
0� / >
/ of DATE
O
0112912021
DRAWN BY
C. GAYNER
• DESIGNED BY
• A. ALLISON
• CHECKED BY
C. KOTARSKI
• • SCALE
• 1"=20'
7
NOTES:
1. CONTRACTOR SHALL VERTICALLY RELOCATE
EXISTING UNDERGROUND UTILITY LINES AS
REQUIRED PER GRADING PLAN ON SHEET C5.0. 3 FT
OF COVER SHALL BE MAINTAINED OVER EXISTING
WATERLINES.
2. A KNOX BOX SHALL BE REQUIRED FOR ANY
STRUCTURE NOT MAINTAINED BY BY 24-HOUR STAFF.
ARCHITECT/CONTRACTOR SHALL COORDINATE WITH
THE FIRE MARSHALS OFFICE FINAL LOCATION.
3. LOCATION OF PROPOSED GAS METER AND 7
APPROXIMATE ALIGNMENT OF GAS SERVICE. 0
CHARLOTTESVILLE CITY GAS DEPARTMENT SHALL BE
RESPONSIBLE FOR THE INSTALLATION OF THE GAS ad ^
SERVICE AND ASSOCIATED METER. PRIOR TO THE
START OF CONSTRUCTION, CONTRACTOR SHALL
COORDINATE WITH CHARLOTTESVILLE CITY GAS z
DEPARTMENT ON THE FINAL SERVICE ALIGNMENT,
METER LOCATION, AND ALL OTHER REQUIREMENTS J (D I --I
FOR LINE INSTALLATION.
4. ALL IMPORVEMENTS ASSOCIATED WITH THE � IJ-I
KESWICK ESTATES GATE IMPROVEMENTS TO BE
\ HANDLED DIRECTLY BY OWNERSHIP. 2
Z
o z
U w
Q Q
W
Lu co
a
J
0
JOB NO.
SCALE V=20' 40241
0 0 20' 40' SHEET NO.
z C4.0
L