Loading...
HomeMy WebLinkAboutSDP202100072 Plan - Submittal (First) Letter of Revision 1 2022-08-29i SPECTRUM DESIGN architects I engineers PLAZA SUITE 1 1 10 CHURCH AVENUE SE ROANOKE, VA 24011 540 . 342 . 6001 FAX: 540 . 342. 6055 www.spectrumpc.com PROJECT NUMBER: H MICHAET- A. RAKES Lic. No. 28199 Aug. 23, 2021 Fi JCL VID C. VENQ Lic. No. 8832 Aug. 23, 2021 CH I"SV- 21034 CITY OF CHARLOTTESVILLE AVON FUEL STATION 1505 AVON STREET EXT CHARLOTTESVILLE, VA 22902 CONSTRUCTION DOCUMENTS AUGUST 23, 2021 INDEX OF DRAWINGS COVER SHEET OWNER: ARCHITECTURE R.J. NARKIE A100 VEHICLE FUELING ISLAND PLAN, CANOPY & CANOPY REFLECTED CEILING PLANS, CHARLOTTESVILLE, VIRGINIA, EQUIPMENT RACK DETAILS PHONE: (434) 970-3664 A101 ELEVATIONS, SECTIONS, & DETAIL CIVIL APPLICANT: C001 GENERAL NOTES C100 EXISTING CONDITIONS SPECTRUM DESIGN C101 DEMOLITION PLAN 10 CHURCH AVENUE SE C101A DEMOLITION PLAN FUEL STATION ROANOKE, VIRGINIA, 24011 C102A DIMENSIONAL AND UTILITY PLAN PHONE: (540) 342-6001 C102B DIMENSIONAL AND UTILITY PLAN C501 CONSTRUCTION DETAILS & NOTES PROJECT INFORMATION: C502 NOT USED TAX MAP: 00100 ELECTRICAL PARCEL NUMBER: 77E1-1 E001 LEGEND, SCHEDULES AND CALCULATIONS OWNER: CITY OF CHARLOTTESVILLE E002 ELECTRICAL SPECIFICATIONS WATERSHED: RIVANNA E102A ELECTRICAL SITE PLAN ZONING DISTRICT: LIGHT INDUSTRIAL E102B ELECTRICAL SITE PLAN NOTE - PROPERTY INCLUDES THE FOLLOWING OVERLAYS: E501 ELECTRICAL DETAILS AIRPORT IMPACT AREA, STEEP SLOPE OVERLAY, FLOOD HAZARD OVERLAY MAGISTERIAL DISTRICT: SCOTTSVILLE SETBACKS: FRONT MINIMUM: 10' FRONT MAXIMUM: NONE SIDE AND REAR MIN: STRUCTURE 507PARKING 30' FROM ALL RESIDENTIAL PROPERTY SIDE AND REAR MAX: NONE SOURCE OF TOPOGRAPHY: A CAD FILE OF THE TOPOGRAPHICAL BY KIRK, HUGHES, AND ASSOCIATES DATED MARCH 8, 2005 PREVIOUS SITE PLAN APPROVALS: SDP1987-20; SDP1990-82; SDP1991-44; SDP1992-30; SDP2001-101; SDP2005-106; SDP2006-131; VARIANCE: VA1988-48 ABUTTING PARCELS ZONING AND USE 77E2-0 LIGHT INDUSTRIAL - MINI WAREHOUSE 77E2-3 LIGHT INDUSTRIAL - OFFICE BUILDING 77E2-1 LIGHT INDUSTRIAL - VACANT INDUSTRIAL 77E1-1 D LIGHT INDUSTRIAL - INDUSTRIAL LIGHT MANUFACTURING 77E1-1 C LIGHT INDUSTRIAL - STORAGE WAREHOUSE 77-16 VACANT RESIDENTIAL DUE TO AERIAL LIMITATIONS NO BUILDING OR STRUCTURE SHALL EXCEED 150'. PARKING FOR AVON FUEL STATION WILL REMAIN THE SAME 42 SPACES FOR BUS PARKING, AND 107 ADDITIONAL SPACES ON THE PROPERTY. PROJECT LOCH 1505 AVON STR CHARLOTTESVI APPROVALS DATE DEPARTMENT OF COMMUNITY DEVELOPMENT PLANNER/ZONING ENGINEER INSPECTIONS ARB DEPARTMENT OF FIRE RESCUE ALBERMARLE COUNTY SERVICE AUTHORITY VIRGINIA DEPARTMENT OF TRANSPORTATION HEALTH DEPARTMENT Z O VJ w D Z O Q O z U w )'zT OM �o � N CONT P.T. 2xWD BLOCKING (TYP) 2x10 P.T. JOISTS ® 16" OC; CUT AS SHOWN (TYP) — DASHED LINES INDICATE P.T. 2x6 GABLE TRIM BEYOND CUT AS SHOWN (TYP ® EXT GABLES; PAINT) PREFINISHED ALUM DRIP EDGE 6„ (TYP) JOIST BRG 2x6 P.T. WD FASCIA; PAINT (TYP) PROVIDE CONT P.T. BLOCKING ® BOTT BTWN P.T. 2x8 BEAM's AS SHOWN & VERTICALLY BTWN P.T. 2xB BEAM's ® GABLE ENDS FOR CLOSURE (TYP; PAINT) EQUIPMENT, QUANTITY AND TYPE AS INDICATED ON PLANS. 0 i� yNIH:T:1�1q 2" 2'-0" (TYP) CONT SHINGLE OVER RIDGE VENT (TYP) ASPHALT SHINGLES OVER 15# FELT ON 1/2" EXT GRADE PLYWD SHEATHING (TYP) 12" 6„ STARTER COURSE 2 ASPHALT SHINGLES (TYP) 1/2" EXT GRADE PLYWD SOFFIT; PAINT (TYP) 2" DIA ALUM SOFFIT VENTS w/INSECT SCREEN CENTER IN JOIST SPACES (TYP) BEAM: 2-CONT P.T. 2x8's, MECH ATT TO STEEL POSTS w/ 2-1/2" DIA THROUGH BOLTS; PAINT (TYP) 3" SQ STEEL POST; PAINT (TYP OF 2) U-BOLTS, TYPICAL (�j P.T. 2xWD BLOCKING CONT SHINGLE OVER RIDGE VENT (TYP) POST POST 2x10 P.T. JOISTS ® 16" OC; CUT 1' 7 1/2" 5' 6" 1'-7 1/2" AS SHOWN (TYP) ASPHALT SHINGLES OVER 15# FELT PREFINISHED ALUM RAKE EDGE ON 1/2" EXT GRADE PLYWO SHEATHING (TYP) (TYP ® GABLES) JYI BEAM: 2-CONT P.T. 2x8's, MECH ATT TO POSTS w/ 2x6 P.T. WD GABLE TRIM; PAINT 2- 1/2" DIA THROUGH BOLTS; CENTER ON POST; PAINT (TYP) (TYP) JOIST BRG EQUIPMENT, QUANTITY AND TYPE AS INDICATED ON PLANS. MOUNTING RACK AND CONDUITS 1/2" EXT GRADE PLYWD SHALL BE PAINTED WITH TWO SOFFIT; PAINT (TYP) COATS OF RUST INHIBITING — — —3 ENAMEL. (COLOR AS SELECTED BY ARCHITECT). 2" DIA ALUM SOFFIT VENTS w/INSECT SCREEN CENTER IN JOIST SPACES (TYP OF 10) --- --- AS FOR 3" SQ STEEL POST; PAINT (TYP OF 2) ONDUQITISUPPORT. IEQUPMENTPAND U-BOLTS, TYPICAL KINDORF PIPE STRAP, SIZE AS REQUIRED, TYPICAL. FIN GRADE FIN GRADE -III=III III III=III °' I IILIII =III III III=III III III=III II III=III - III III III III=III- -� I I —III III —III —I I - III III=1 III III III—III=III III=III= III=III=1 I I=III III III —II �_ "�—III=III=III 1=III=III =III=III=III=III=III=III=III 11=III=III '- '. III—III—III=i" IIL—III=11 a III III —I III III III—III=III III —III= III —III —I - II=11I—IIL--'' � III III ' - I III III III III III=1 I I III III=11 I I I III III III IIL—' N I-11111 I II I II I I-1 I I IT_I=1 � I I � 1-1 I1=1 I1-1 I I —III— I C I —III —I ,. ..: I I —I I1-� CONCRETE, TYPICAL. LONGITUDINAL SECTION EQUIPMENT RACK MOUNTED AT GRADE DETAILS NOT TO SCALE CANOPY GUTTER BY CANOPY MANUF (TYP OF 2) — CANOPY COLUMN BY CANOPY MANUF. 10" SO MAX (TYP OF 2) 3 A101 CANOPY BY CANOPY MANUF (TYP) — CANOPY SOFFIT PANELS BY CANOPY MANUF (TYP) CANOPY GUTTER BY CANOPY MANUF (TYP OF 2) SIDING PER CANOPY MANUF (TYP, REF ELEVS AND SECTIONS) 24'-0" LIGHT PER CANOPY MANUF; CENTER IN SOFFIT PANEL (TYP OF 4 PER CANOPY F SHOWN, REF ELECTRICAL) 0 o J U q 0 c 0 M 0 U ® c COL CANOPY REFLECTED CEILING PLAN 1/4'=1'-0' PLAN NORTH 'a CANOPY GUTTER BY CANOPY MANUF (TYP OF 2) CANOPY COLUMN BY CANOPY MANUF. 10" SO MAX (TYP OF 2) 3 A101 PROVIDE FIRE EXTINGUISHER; STRAP TO COL (TYP; 1 PER CANOPY) — CANOPY BY CANOPY MANUF (TYP) CANOPY GUTTER BY CANOPY MANUF (TYP OF 2) SIDING PER CANOPY MANUF(TYP) 24'-0" 0 J U 0 0 � M 0 U 0 I COL CANOPY PLAN 'a SPECTRUM DESIGN architects I engineers Plaza Suite 1 10 Church Avenue, SE Roanoke, VA 24011 540.342.6001 SPECTRUMPC.COM NEW CONSTRUCTION FOR AVON FUEL STATION Spectrum Design Project No.: 21034 TJCL AVID C. VENAB Lic. No. 8832 � AUG 23, 2021 4;1 CHIT�GiII PROJ. MGR.: CHECKED BY: DRAWN BY: DCV DGM DGM SHEET ISSUE DATE: 08.23.2021 PROJECT PHASE: BID DOCUMENTS REVISION NUMBER DATE KEY PLAN: SHEET NAME: VEHICLE FUELING ISLAND PLAN, CANOPY PLAN NORTH & CANOPY REFLECTED CEILING PLANS, EQUIPMENT RACK DETAILS PROVIDE HIDDEN DOWNSPOUT BY CANOPY MANUF FROM PERIMETER GUTTER TO COLUMN AND EXTEND CONCEALED INSIDE COLUMN TO GRADE. PROVIDE OUTLETAT GRADE. (TYP OF 2 PER CANOPY; REF SECTIONS FOR MORE DETAIL) PROVIDE HIDDEN DOWNSPOUT BY CANOPY MANUF FROM PERIMETER GUTTER TO COLUMN AND EXTEND CONCEALED INSIDE COLUMN TO GRADE. PROVIDE OUTLETAT GRADE. (TYP OF 2 PER CANOPY; REF SECTIONS FOR MORE DETAIL) SHEET NUMBER: Al 00 CANOPY BY CANOPY MANUF (TYP) SPECTRUM DESIGN architects I engineers O N O N 0 N PLAN FOR LOCATION. REF CIVIL FOR DETAIL(TYP) SIDING PER CANOPY MANUF (TYP) FUEL CONTROLLER BEYOND FUEL DISPENSER BEYOND — INDICATE CONC FDN BEYOND PER CANOPY MANUF (TYP) CANOPY BY CANOPY MANUF (TYP) 0 SOFFIT PANELS PER CANOPY MANUF (TYP) FUEL TANK BEYOND (TYP) DEF DIESEL ADDITIVE FUEL DISPENSER COLUMN BY BEYOND (TYP) CANOPY MANUF.10" SO MAX (TYP OF 2 PER CANOPY) <? wm STL BOLLARD REF CIVIL FOR DETAIL (TYP) 8" THK CONCRETE ISLAND SLAB 8" THK DRIVE AISLE (TYP) CONCRETE PAVING (TYP) IM aTuv nQwG e�e� ❑ }1 1 Oil YUV ! nikl � 101 I1NM1 CONCRETE PAVING SLAB (TYP)V Vw'V (TYP) DASHED LINES INDICATE CONC FDN BEYOND PER CANOPY MANUF (TYP) 2 A100 EA101 SIDING BY CANOPY MANUF (TYP) CANOPY BY CANOPY MANUF (TYP OF 2) CANOPY GUTTER BY CANOPY MANUF (TYP OF 2) I I I I I I I I DASHED LINES INDICATE HIDDEN DOWNSPOUT BY CANOPY MANUF; EXTEND CONCEALED TO COLUMN AND TO OUTLET AT GRADE AS SHOWN (TYP OF 2) I I FORM AROUND BRG/BASE PLATE AS SHOWN. POUR SEPARATELY w/ j' EXP JT SURROUND (TYP) 0 9 BASE PLATE AND ANCH d BOLTS PER CANOPY MANUF (TYP) CONC FOUNDATION PER CANOPY MANUF I ED (TYP) 4'-0" SOFFIT PANELS BY CANOPY MANUF (TYP) COLUMN BY CANOPY MANUF.10" SO MAX (TYP OF 2 PER CANOPY) FIRE EXTINGUISHER; STRAP TO COLUMN (TYP 1 PER CANOPY) OkUM , BRG PLATE, FDN (TYP) d •. ED 8" CONC ISLAND SLAB VEHICLE FUELING CANOPY ELEVATION 1/4'=1'-0" c M BEYOND — AIR MACHINE BEYOND VEHICLE FUELING CANOPY ELEVATION SIDING BY CANOPY MANUF (TYP) — 8" THK CONC ISLAND SLAB(TYP) II CANOPY GUTTER BY CANOPY MANUF FIRE EXTINGUISHER; (TYP OF 2) STRAP TO COLUMN (1 PER CANOPY; TYP) FUEL TANK BEYOND DASHED LINES INDICATE HIDDEN DOWNSPOUT FUEL DISPENSER BY CANOPY MANUF; BEYOND EXTEND CONCEALED TO COLUMN AND TO OUTLET AT GRADE AS SHOWN (TYP OF 2) J' EXP J OI NT w/ I I SEALANT I I SLOPE g':1'-0" I I b 8 d c: 8" THK DRIVE AISLE d ° 8" THK CONC ISLAND CONCRETE PAVING (TYP) (TYP)SLAB d ° COLUMI 1, ERG PLATES, FDN (TYP) BASE PLATE AND ANCH BOLTS PER CANOPY MANUF (TYP) ED ED ED FORM AROUND BRG/BASE PLATE AS SHOWN. POUR SEPARATELY w/ J' EXP JT 4'-0" SURROUND (TYP) II L L— I I SOFFIT PANELS BY CANOPY MANUF (TYP) FUEL CONTROLLER BEYOND COLUMN BY CANOPY MANUF.10" SO MAX (TYP OF 2 PER CANOPY) STL BOLLARD REF CIVIL FOR DETAIL (TVP) J' EXP J OI NT w/ SEALANT 8" THK DRIVE AISLE CONCRETE PAVING (TYP) SLOPE "'A'-0" a •d CONC FOUNDATION ° PER CANOPY MANUF (TYP) 8.. 1'COkUM1 1, BRIG PLATES, FDN (TYP) ED 4'-0" SOFFIT PANELS PER CANOPY MANUF (TYP) FIRE EXTINGUISHER; STRAP TO COLUMN (TYP 1 PER CANOPY) COLUMN BY CANOPY MANUF.10" SO MAX (TYP OF 2 PER CANOPY) DASHED LINES INDICATE CONC FDN BEYOND PER CANOPY MANUF (TYP) 0 r� 9 CANOPY BY CANOPY MANUF (TYP OF 2) CANOPY GUTTER BY CANOPY MANUF (TYP OF 2) 0 M Plaza Suite 1 10 Church Avenue, SE Roanoke, VA 24011 540.342.6001 SPECTRUMPC.COM NEW CONSTRUCTION FOR AVON FUEL STATION Spectrum Design Project No.: 1�j C VID C. AUG 23, 2021 PROD. MGR.: CHECKED BY: DRAWN BY: DCV DGM DGM SHEET ISSUE DATE: 08.23.2021 PROJECT PHASE: BID DOCUMENTS REVISION NUMBER KEY PLAN: SHEET NAME: ELEVATIONS, SECTIONS, & DETAIL 21034 DATE VEHICLE FUELING CANOPY SECTION 1/4'=1'-0" VEHICLE FUELING CANOPY SECTION 1/4"=1'-0" SHEET NUMBER: Al 01 C C/) Cn Cn cu C 0'g C/) RASS CC U CU C Cn anor— �1g 9 c CC cu I I I I I I MATCHUNE C102B I I RESTRIPE WHERE 0 DISTURBED (TYP.) I� -1- I NEW ASPHALT PAVEMENT .I' SEE DET. 3/C501 I . I DOUB'LE-'.D.1—.1 I' /T SEE DET. 1 / 501 DEF DIESEL ADDITIVE 0 31.72' FIRE EXTINGUISHER ,y ,...: :...,:•. 1 1 g + ,10:. �. '• :I .:...o,. 0,000 GALLON • C '' ! DIESEL :;' a D SEL TANK d, I d. Cn NEW CONCRETE PAVEMENT a : ;'.:•„ , �..,:' 1 FOR BUS LANE SEE DET. 3/C501 :'o .� :' "' O> GRASS d d >• • ®, L^I �� may] .I� o '' CONNECT INTERN I ':•`:',• PIPING TO 4 PV ' I '• •• .,:,; : • ".: '..>,`. a AND DIRECT TO.. S ' q 9 ,0 N.'1'` I 1 r I'� .(TYPICAL . . Y r..: . a. p lJ d 0 I FIRE EXTINGUISHER' �•n• °:• :�>:: ,.:`.:: gip; . .�. . . • ` a .30.00„f. • 12,000 GAL NEW 6" BOLLARD a d6 '. ' GAS , ': • a GAS' TANK. SEE DET. 2/C501 , ; , > d b. ,. • # 4'1' ADD T ME B D TEM # 1 PSQ �20.5 DOWNSPOUT AIN LEADER UCTURE #23. x NEW ASPHA�T SEE DET. 3 C REPLA E EXISTING E PANEL AND REINSTA HARDW RE IN SAME AS BE ORE. 5 kl KEYNOTES: 0 DISPENSER 0 EMERGENCY SPILL BOX 24"X48" Q AIR COMPRESSOR ® 24" DIAMETER ABSORBENT BARREL 50 FUEL MANAGEMENT PEDESTAL 12•� GENERAL NOTES: 1. CONTRACTOR SHALL INSTALL 'NO SMOKING/NO OPEN FLAME"SIGNS OR STICKERS THAT MEET NFPA DIMENSIONS AND LOCATED AT NFPA REQUIRED LOCATIONS. AT A MINIMUM, SIGNAGE SHALL BE PLACED AT THE FOLLOWING LOCATIONS: A. EACH SIDE OF EACH STORAGETANK B. TWO SIDES OF EACH CANOPY COLUMN 2. CONTRACTOR SHALL INSTALL SIGNAGE ABOVE EACH TANK FILL POINT WITH THE WORDS 'FILL A- PROCEDURE: SUPPLIER/OPERATOR SHALL �1 DETERMINE THE VOLUME REQUIRED FROM INITIAL LEVELS TO 90% OF THE TANK CAPACITY PRIOR TO INITIATING FIILLJNG + OPERATIONS CONTRACTOR SHALL INSTALL SIGNAGE ON CH SIDE OF EACH TANK IDENTIFYING THE MA IAL AND CAPACITY OF EACH TANK IN ACCOR NCE WITH NFPA 704 EP WAYNE COMMERCIAL 3ER VIJI LIVJLI\ I IVJL 001 DISPENSER DETAIL C102A NO SCALE NOTE: 1. DISPENSER HOSE TO FACE TOWARD EACH SIDE OF CONCRETE ISLAND GA 4- V > x x x_ x CC x \� \ x x x x x-� x_x C -- _ x— x SURFACE COVER LEGEND — \ \ CLF x x x —� __ — — � ASPHALT SURFACE - P1 — — — — — _ _ — _ _ \ DET. 002/C501. — — — C) CONC. PAVEMENT (BUS LANE) - REFER TO P2 DET. 0 0 2 / C 5 01. — — — — — ' •`..: CONC. SURFACE (ISLAND SLAB) - P3 DET.002/C501. N 56-33'43" W - —485.842_�TOTAL) 10' 5' 0 1" = 10'-0" EP �— WOOD FRAME SHE �C SALT SPREADER`. SPECTRUM DESIGN architects I engineers Plaza Suite 1 10 Church Avenue, SE Roanoke, VA 24011 540.342.6001 SPECTRUMPC.COM /1 NEW CONSTRUCTION FOR AVON FUEL STATION Spectrum Design Project No.: �'p,LTH OF VMICHA A. RAKES Lic. No. 28199 °9 AUG 23, 2021� PROJ. MGR.: CHECKED BY: DRAWN BY: DCV MAR CDL SHEET ISSUE DATE: 08.23.2021 PROJECT PHASE: BID DOCUMENTS REVISION NUMBER KEY PLAN: SHEET NAME: DIMENSIONAL & UTILITY PLAN SHEET NUMBER: C1 02A 21034 DATE SPECTRUM architects I DESIGN engineers a 00 N N N O N ELECTRICAL GENRAL NOTES: SEE SHEET E001 FOR LEGEND, PANEL SCHEDULES, LIGHTING FIXTURE SCHEDULE, LIGHTING CALCULATION AND ONE LINE DIAGRAM. 2. SEE SHEET E002 FOR ELECTRICAL SPECIFICATIONS. 3. SEE SHEET E501 FOR HAZARDOUS LOCATION SPECIFIC DETAILS AS DETERMINED BY NEC 2014 ARTICLE 514. OELECTRICAL DEMOLITION NOTES: CONTRACTOR SHALL: 1. DISCONNECT ELECTRICAL AND TELECOMMUNICATIONS CIRCUITS THE EXISTING UST SYSTEM, DISPENSER CANOPY, DISPENSERS, CAMERAS AND ALL ITEMS WITH SERVICE TO THE CANOPY SYSTEM. 2. RETRACT ELECTRICAL AND TELECOMMUNICATIONS CIRCUITS TO A DISTANCE OUTSIDE OF THE AREA OF DISTURBANCE AND PROTECT FOR RECONNECTION. 3. CAMERAS ARE TO BE SALVAGED AND REINSTALLED ON NEW CANOPY'S. OELECTRICAL SHEET NOTES: CONTRACTOR SHALL: 1. SEE CIVIL SHEET C501 FOR DESCRIPTION AND COORDINATION OF EQUIPMENT TO BE INSTALLED. RECONNECT NEW EQUIPMENT WITH CIRCUITS RETAINED DURING DEMOLITION. VERIFY COMPATIBILITY OF EXISTING CIRCUITS IN SUB -GAS PANEL LOCATED IN THE UTILITY ROOM OF THE BUS DISPATCH BUILDING. 2. ROUGH IN (16 TOTAL) 15 3/4° IMC ELECTRICAL CONDUITS FOR USE IN RECONNECTION AND 1 SPARE 3/4"IMC ELECTRICAL CONDUIT IN TRENCH FOR ELECTRICAL CONNECTIONS AND (10 TOTAL) CONDUITS FOR LOW VOLTAGE CABLING FOR THE RECONNECTION OF NEW EQUIPMENT. ROUTE TO TO PULL BOXES LOCATED OUTSIDE THE HAZARDOUS AERA. 3. PULL EXISTING ELECTRICAL WIRING RETAINED FROM SUB GAS PANEL IN NEW CONDUITS TO CANOPY AND CONNECT TO THE FOLLOWING EQUIPMENT LOCATIONS: SEE RE -WORKED SUB GAS PANEL SCHEDULE SHEET E001. 3A. (2) NEW SUB PUMPS, POWER. CONNECT TO SUB GAS PANEL IN THE UTILITY ROOM. 3B. (2) NEW DISPENSERS, POWER. CONNECT TO SUB GAS PANEL IN THE UTILITY ROOM. 3C. (1) NEW FUEL MANAGEMENT PEDESTAL AND (1) FUEL MANAGEMENT SYSTEM RETAINED FROM DEMOLITION. CONNECT TO SUB GAS PANEL IN THE UTILITY ROOM. 3D. (8) NEW CANOPY LIGHTS, CIRCUIT TO CIRCUITRY RETAINED DURING DEMOLITION OF EXISTING LIGHTS. CONNECT TO EXISTING LIGHTING CONTACTOR LOCATED IN THE UTILITY ROOM. 3E. (1) AIR COMPRESSOR RETAINED FROM DEMOLITION, RE -CONNECT TO SUB GAS PANEL LOCATED IN UTILITY ROOM. 3F. (1) BLUE DEF ADDITIVE PUMP, CIRCUIT TO UTILITY ROOM MAIN PANEL AVAILABLE CIRCUITRY FOR A 120V , 30A MOCP. 3G. (2) SINGLE PHASE CONTROL BOXES, CONNECT TO SUB GAS PANEL IN THE UTILITY ROOM. 4. CONDUITS TO NEW CAMERA LOCATIONS WITH PULL STRING. CIRCUITRY BY OWNER (CONDUIT ONLY WITH PULL STRING, CAMERAS AND CIRCUITRY BY OTHERS FOR CAMERAS). 5. INSTALL NEW LIGHTS, UNDER CANOPY SYSTEM. SEE LIGHTING FIXTURE SCHEDULE E001 FOR DESCRIPTION OF NEW LIGHTS. 6. ELECTRICAL PULL BOX OUTSIDE OF HAZARDOUS AREA. 7. COMMUNICATIONS PULL BOX OUTSIDE OF HAZARDOUS AREA. 8. EMERGENCY SHUTOFF OUTSIDE OF HAZARDOUS AREA. 9. CONDUITS FROM PULL FROM PULL BOX LOCATIONS TO FUEL ISLAND WILL BE ENCASED IN CONCRETE. SEE SHEET E501 FOR TYPICAL DETAILS. Plaza Suite 1 10 Church Avenue, SE Roanoke, VA 24011 540.342.6001 SPECTRUMPC.COM 7 INIEW CONSTRUCTION FOR AVON FUEL STATION Spectrum Design Project No.: 14011/1/10#01 00 .`<J��" NL T$ Opp 0100 JEFFREY W. WIGGINGTON y Lie. No. 032781 ",'o4UG 23, 2021�4w' ,,,0ss/ONA' ' 44` PROD. MGR.: CHECKED BY: DRAWN BY: DCV JWW CLH SHEET ISSUE DATE: 08.23.2021 PROJECT PHASE: BID DOCUMENTS REVISION KEY PLAN: SHEET NAME: NUMBER ELECTRICAL SITE PLAN 21034 DATE 101-011 = ===- SHEET NUMBER: El 02A