HomeMy WebLinkAboutSE202200052 Correspondence 2022-08-30 (3)SITE PLAN NOTES:
1. THIS SITE PLAN REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER
AT THE TIME OF THIS DESIGN. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO
CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK
FOR THIS PROJECT.
2. ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAX CABLE ARE SHOWN FOR REFERENCE
ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALL PROPOSED AND EXISTING
EQUIPMENT AND STRUCTURES DEPICTED ON THIS PLAN. BEFORE UTILIZING EXISTING CABLE
SUPPORTS, COAX PORTS, INSTALLING NEW PORTS OR ANY OTHER EQUIPMENT, CONTRACTOR
SHALL VERIFY ALL ASPECTS OF THE COMPONENTS MEET THE ATC SPECIFICATIONS.
3. THIS CONSTRUCTION DRAWING SET IS NOT INTENDED TO REPRESENT ANY ELECTRICAL
DESIGN OTHER THAN THE GROUNDING SHOWN, OR TO BE USED TO OBTAIN AN ELECTRICAL
PERMIT. AN ELECTRICAL PERMIT IS REQUIRED TO WIRE UP THE PROPOSED EQUIPMENT. ANY
ELECTRICAL UPGRADES WILL BE ENGINEERED AND PERMITTED IN A SEPARATE
CONSTRUCTION DRAWING SET.
4. THE TOWER IS LOCATED IN ZONE "X," AREAS DETERMINED TO BE OUTSIDE THE 0.2%ANNUAL
CHANCE FLOODPLAIN ACCORDING TO FEMA COMMUNITY PANEL#51003C0145D, DATED
FEBRUARY D4, 2D05.
LEGEND
®
GROUNDING TEST WELL
ATS
AUTOMATIC TRANSFER SWITCH
B
BOLLARD
CSC
CELL SITE CABINET
D
DISCONNECT
E
ELECTRICAL
F
FIBER
GEN
GENERATOR
G
GENERATOR RECEPTACAL
HH, V
HAND HOLE, VAULT
IB
ICE BRIDGE
K
KENTROX BOX
LC
LIGHTING CONTROL
M
METER
PB
PULL BOX
PP
POWER POLE
T
TELCO
TRN
TRANSFORMER
CHAINLINK FENCE
53'-0"
EXISTING
EXISTING 3'-6" X 8'-0" 4'-0" X 10'-0"
EMPTY CON. PAD BYUOTHERS
IPMENT PAD N
BY OTHERS
EXISTING 3'-6" X 8'-0"
EMPTY CON. PAD
BY OTHERS EXISTING UTILITY H-FRAME o
EXISTING AT&T MOBILITY I BY OTHERS (TYP.) N
(12) 7-5/8" COAX CABLES
(2) 0.40" FIBER TRUNKS ,
(4) 0.82" OC TRUNKS
(TO REMAIN) PROPOSED AT&T MOBILITY
G GRAVEL EQUIPMENT TO BE INSTALLED INSIDE 1
SURFACE EXISTING EQUIPMENT SHELTER:60
(1) 164 AH EAST PENN HT170ET 48V
rn EXISTING 2'-6" X 74'-0" M BATTERY STRING
o EQUIPMENT PLATFORM m
Io BY OTHERS h
EXISTING 702'-6"
SELF SUPPORT TOWER EXISTING CHAIN -LINK
FENCED COMPOUND
EXISTING 8'-0" X 8'-O"
EMPTY CON. PAD D
BY OTHERS N O
EXISTING AT&T MOBILITY MID
11'-6" X 20'-0" EQUIPMENT SHELTER D L
WITHIN 240 SO FT GROUND SPACE
EXISTING ICE BRIDGE 0 o EXISTING AT&T MOBILITY
BY OTHERS (TYP.) 8'-0" o .I EQUIPMENT INSTALLED INSIDE EXISTING
EQUIPMENT SHELTER.-
(1) ALPHA 48V POWER PLANT
(5) CORDEX CXRF HP 48-4KW RECTIFIERS
(4) CORDEX CXDF 48-24/2KW CONVERTERS
EXISTING (2) 164 AH EAST PENN HT170ET 48V STRINGS
42'-9" X 5 EQUIPMENT D D (TO REMAIN)
BUILDDINGING BY OTHERS (1) CORDEX CXRF HP 48-4KW RECTIFIER
/ (TO BE REMOVED)
DETAILED SITE PLAN
6CALE:1'=2V
0 20' 40'
SCALE: 1"=20'(17X17)
1"=10'(22X34)
�l
F 7 F PP
60TRN.
MID
Ak
AMflme
1
TOUR DOM PRIXESEW
326TRYON ROAD
RALEIGH, NC 27603-3530
OFFICE: (919) 661Q51
www.tepgroup.net
REV. DESCRIPTION BY DATE
AA PRELIMINARY RRG 01/11/22
QO 100% CONSTRUCTION JW 01/19/22
IL
ATC SITE NUMBER: 88274
ATC SITE NAME: ADVANCE MILLS VA
AT&T MOBILITY SITE NUMBER:
VAL02322
AT&T MOBILITY SITE NAME:
PINEY MOUNTAIN
SITE ADDRESS:
5317 PINEY MTN RD
RUCKERSVILLE, VA 22968-1632
SEAL:
0
O� G
0 TYLER SHENK Z
U Lic. No. 060894
APO
xl��ONAL6NG�[,
01/19/22
AT&T
DATE DRAWN:
07/19/22
ATC JOB NO:
73744214
CUSTOMER NAME:
PINEY MOUNTAIN
CUSTOMER ID:
VAL02322
DETAILED SITE PLAN
SHEET NUMBER.
REVISION.
C-101
0
Q