Loading...
HomeMy WebLinkAboutSE202200052 Correspondence 2022-08-30 (3)SITE PLAN NOTES: 1. THIS SITE PLAN REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT. 2. ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAX CABLE ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALL PROPOSED AND EXISTING EQUIPMENT AND STRUCTURES DEPICTED ON THIS PLAN. BEFORE UTILIZING EXISTING CABLE SUPPORTS, COAX PORTS, INSTALLING NEW PORTS OR ANY OTHER EQUIPMENT, CONTRACTOR SHALL VERIFY ALL ASPECTS OF THE COMPONENTS MEET THE ATC SPECIFICATIONS. 3. THIS CONSTRUCTION DRAWING SET IS NOT INTENDED TO REPRESENT ANY ELECTRICAL DESIGN OTHER THAN THE GROUNDING SHOWN, OR TO BE USED TO OBTAIN AN ELECTRICAL PERMIT. AN ELECTRICAL PERMIT IS REQUIRED TO WIRE UP THE PROPOSED EQUIPMENT. ANY ELECTRICAL UPGRADES WILL BE ENGINEERED AND PERMITTED IN A SEPARATE CONSTRUCTION DRAWING SET. 4. THE TOWER IS LOCATED IN ZONE "X," AREAS DETERMINED TO BE OUTSIDE THE 0.2%ANNUAL CHANCE FLOODPLAIN ACCORDING TO FEMA COMMUNITY PANEL#51003C0145D, DATED FEBRUARY D4, 2D05. LEGEND ® GROUNDING TEST WELL ATS AUTOMATIC TRANSFER SWITCH B BOLLARD CSC CELL SITE CABINET D DISCONNECT E ELECTRICAL F FIBER GEN GENERATOR G GENERATOR RECEPTACAL HH, V HAND HOLE, VAULT IB ICE BRIDGE K KENTROX BOX LC LIGHTING CONTROL M METER PB PULL BOX PP POWER POLE T TELCO TRN TRANSFORMER CHAINLINK FENCE 53'-0" EXISTING EXISTING 3'-6" X 8'-0" 4'-0" X 10'-0" EMPTY CON. PAD BYUOTHERS IPMENT PAD N BY OTHERS EXISTING 3'-6" X 8'-0" EMPTY CON. PAD BY OTHERS EXISTING UTILITY H-FRAME o EXISTING AT&T MOBILITY I BY OTHERS (TYP.) N (12) 7-5/8" COAX CABLES (2) 0.40" FIBER TRUNKS , (4) 0.82" OC TRUNKS (TO REMAIN) PROPOSED AT&T MOBILITY G GRAVEL EQUIPMENT TO BE INSTALLED INSIDE 1 SURFACE EXISTING EQUIPMENT SHELTER:60 (1) 164 AH EAST PENN HT170ET 48V rn EXISTING 2'-6" X 74'-0" M BATTERY STRING o EQUIPMENT PLATFORM m Io BY OTHERS h EXISTING 702'-6" SELF SUPPORT TOWER EXISTING CHAIN -LINK FENCED COMPOUND EXISTING 8'-0" X 8'-O" EMPTY CON. PAD D BY OTHERS N O EXISTING AT&T MOBILITY MID 11'-6" X 20'-0" EQUIPMENT SHELTER D L WITHIN 240 SO FT GROUND SPACE EXISTING ICE BRIDGE 0 o EXISTING AT&T MOBILITY BY OTHERS (TYP.) 8'-0" o .I EQUIPMENT INSTALLED INSIDE EXISTING EQUIPMENT SHELTER.- (1) ALPHA 48V POWER PLANT (5) CORDEX CXRF HP 48-4KW RECTIFIERS (4) CORDEX CXDF 48-24/2KW CONVERTERS EXISTING (2) 164 AH EAST PENN HT170ET 48V STRINGS 42'-9" X 5 EQUIPMENT D D (TO REMAIN) BUILDDINGING BY OTHERS (1) CORDEX CXRF HP 48-4KW RECTIFIER / (TO BE REMOVED) DETAILED SITE PLAN 6CALE:1'=2V 0 20' 40' SCALE: 1"=20'(17X17) 1"=10'(22X34) �l F 7 F PP 60TRN. MID Ak AMflme 1 TOUR DOM PRIXESEW 326TRYON ROAD RALEIGH, NC 27603-3530 OFFICE: (919) 661Q51 www.tepgroup.net REV. DESCRIPTION BY DATE AA PRELIMINARY RRG 01/11/22 QO 100% CONSTRUCTION JW 01/19/22 IL ATC SITE NUMBER: 88274 ATC SITE NAME: ADVANCE MILLS VA AT&T MOBILITY SITE NUMBER: VAL02322 AT&T MOBILITY SITE NAME: PINEY MOUNTAIN SITE ADDRESS: 5317 PINEY MTN RD RUCKERSVILLE, VA 22968-1632 SEAL: 0 O� G 0 TYLER SHENK Z U Lic. No. 060894 APO xl��ONAL6NG�[, 01/19/22 AT&T DATE DRAWN: 07/19/22 ATC JOB NO: 73744214 CUSTOMER NAME: PINEY MOUNTAIN CUSTOMER ID: VAL02322 DETAILED SITE PLAN SHEET NUMBER. REVISION. C-101 0 Q