HomeMy WebLinkAboutSDP201600066 Plan - Approved Initial Site Plan 2016-12-28A- 1. COVER SHEET 2. PROPERTY INFORMATION 3. EXISTING CONDITIONS PLAN 4. SITE PLAN 5. TRANSFER STATION LAYOUT 6. BUILDING ELEVATIONS u- V) 1 z 0 RIVANNA SOLID WASTE AUTHORITY FAO *-T n. too M& CA P- M-A imp I rAllha."A oki-a-lu-1 to—"i VIRGINIA BEACH, VA 23452 (757) 466m3361 PROPERTY LINE,,, .......... .......... ............. .......... ............... .......... ......... .................................... ....... .............. - 111". ... --- . ........................ .............. ........... .................. ............. ........ - .......................... ............. .......... - ....... .................. ................. ....1-1......... ......................... 1-1. 1111-1-- .......... .... ...................... I ............................. .................... . ........... ....................... ............. ......................... .................. ... .................... I-- .... ................... ........ _ - , *­ ............................... .............. .......... ....... ....... ......................................... ♦ .......... ......... .... ij ........... ............ ....... ....... ...... ....................... ....... ........... ....................... ....... ............................... ........ ...................... * ...... ...... L • ..........♦ .................. ............ ................... ................................. ........................ I. -I ......... ................. ........... ...................... .......... * ....... ........... .. .. .. ............. ............. .............. TRANSFER ........... ... ... .... ........ .. ......... STATION 'LOCATION I . .................. ................... IF ... if ... ......... io --00 ft . MAP LOCATION NJ SCALE., 1 =10000" Submittal Type Reviewed and Approved by the Community De- to rr nt Depp ,ttment Date - File# 10 C20 ature 0 V) 5; W z�1 W P*- Z 00 Oct w W 0 CA LU IUL z W z Ld fit._'_.' Ld Uj 0 rc, 0 3: F. Wo z (7) W .1e > W � W 1111 CC. > W it UJ eo% %kip 10j 0 0 z z z > Ld -j Q) 04 4 > V) cco (.Ju z �;g 0 < W IL) 1.0 0 rt-0 W 0 C-4 ' Z< Z f: W xN,0 - (n n o x C3 g5; � � W $Z zz Z zid cr. W Uj I V- 0 a z "ro) C) W () z < C? (n 0 IWO CC to < ZO 0 V<) c4 CL CADD FILE: SHT01 —COVER DATE: NOV 2016 SCALE: AS SHOWN DRAWING NO. 1 6 1 of MWIMMOMMMEMMOMMMIM Q z CL u,j Q u_. uj Q� x z F_ F_ v), 01-1. LAJ. U— Q) z x uj 0 L1_ Lki x x ui CK x V) 0 c6 QD 0 W uj 0 z TIC. 71— j. m A 'A T L7 7 74-4C� /* Ilk _'-7 N X, P 2 A -4; 0 m if -4. 4 -1 m '54 _6 tat 'p. e;, 4A 1000 ft 7,'� �24 U 1.3,44 v A. N A let , 47 3 a--Z El - TAX P SCALE: 1 ABUTTING PARCEL INFORMATION: TAX MAP/PARCEL NO, OWNER ZONING PRESENT USE VACANT RESIDENTIAL 73-12A RIVANNA SOLID WASTE AUTHORITY RA LAND VACANT RESIDENTIAL 73-IIA RIVANNA SOLID WASTE AUTHORITY RA LAND 73-30E GBW, LLC RA RESIDENTIAL 73-30C SIKES, LLOYD S. OR MARY E. RA RESIDENTIAL VACANT RESIDENTIAL 73-300 RIVANNA SOLID WASTE AUTHORITY RA LAND MORRIS, VIVIAN M TRUSTEE OF THE VIVIAN M 73-38B RA RESIDENTIAL MORRIS REVOCABLE LIVING TR MORRIS, VIVIAN M TRUSTEE OF THE VIVIAN M 73-27A RA OPEN MORRIS REVOCABLE LIVING TR 73-27J PELLETIER, SHAWN J, & MELLISA M. RA RESIDENTIAL 73-27B WILLIAMS, WILLIAM A. OR FAYE G. RA RESIDENTIAL 73-27H MARKEY, MICHAEL RA RESIDENTIAL 73-27G GIBSON, NATHANIEL P. RA RESIDENTIAL VACANT RESIDENTIAL 73-27Z POUNDING BROOK, LLC RA LAN D PALUMBO, SALVATORE JOSEPH JR. OR CAROL 73-27EI RA RESIDENTIAL MOSELEY 73-27E1 MORRIS, IRENE B RA RESIDENTIAL 73-27E2 MORRIS, HARRY SAMUEL OR 13ARBAkA RICKARD RA RESIDENTIAL 73-20 ST.JOHN THE BAPTIST 1) M S, C/O TREASURER RA CHURCH WHOLLEY, MICHAEL C & KATHLEEN S WHOLL.EY VACANT RESIDENTIAL 73-17 RA TRS OF THE WHOLLEY FAMILY TRUST LAND VACANT RESIDENTIAL 73-17E RIVANNA SOLID WASTE AUTHORITY RA 73-17D RIVANNA SOLID WASTE AUTHORITY RA RESIDENTIAL 73-16D GRAF� RODERICK E RA RESIDENTIAL 73-14A FORBES, DENNIS M OR M-ONICA S OR PATSY Y HITER RA RESIDENTIAL 73-14AI S-NEAD, STUART M RA RESIDENTIAL . VACANT RESIDENTIAL 73-14A2 BARRELL, CHAR LES D OR JANE I RA LAND 73-15 BAKER, MARY JORDAN RA RESIDENTIAL 73-14B STRANGE, EDWIN L RA RESIDENTIAL 73-14 BATTON, LAURICE ELTON OR REBECCA M RA RESIDENTIAL VDOT 1-64 LEGEND: EXISTING CONTOURS (INDEX) .... EXISTING ROAD (PAVED) EXISTING ROAD (UNPAVED) EXISTING TREELINE EXISTING PROPERTY LINE BUILDING SETBACK EXISTING BENCHMARK 4 e A I........ . . -v 7— ...... ....... .... ...... ...... ..... 5 j ........... .... .... ... < -Ile . ....... ........ s........ . . ........ ........ .... . .. ........ z e 0 el > Ld el Ij 'Ilk . . ... .... .. . ......... ....... .............. t7 t0 tt. ..... . ..... I—. . ............ ..... .......... ....... .. . ..... Ilk ? f 0 tz 0 j f LL 1-15"...., ... ... .......... ........ ....... Mao t ell m 615860-99 cc E: 1954067.37 w I t ELEV. 649.77 s0 CL C) K ....... . _e 'F , Ir f w,�� tLLj .. . ...... . ............ ....... gel 4 SHEET 3 tN' 614714.69 E' 1955736., 5 ELEV. 716,23 _e, 477 --- ----------- - 1 4 e�,_ p... ......... . . ........ ....... EXISTING PROPERTY .... . ...... . INGRESS & EGRESS le, \ % 2 5) a K MAD EY., r_\1, SCALE: 1 300" GENERAL INFORMATION PROPERTY AD DRESS: 4576 DICK WOODS ROAD, CHARLOTTESVILLE, VA 22903 DEVELOPMENT. NAME: IVY SOLID WASTE TRANSFER STATION OWNER: RIVANNA SOLID WASTE AUTHORITY DEVELOPER': - RIVANNA SOLID WASTE AUTHORITY TAX MAP AND PARCEL NUMBER: 73-28 BOUNDARY DIMENSIONS- VARIES- AREA=300,.585 AC. ZONING DISTR ICT: RURAL AREAS MAGISTERIAL DISTRICT: SAMUEL MILLER, ALBEMARLE COUNTY PROFFERS: :: NONE WATERSHED: UPPER MECHUMS RIVER WATER SUPPLY 27 w Z 0 .j 0 cic w 0) U. 0 z W LLJ z i cc 0 cq UJ 0 Z cm 04 UJ > LU , III ui C.) Lij x w 0 t: 00 0 2 J..j (r) L0 a: < (7) < to z z 04 > Q V) �:< m 'y t­ :5 ccz IN LLJ W Z 5: CL ct� ur ;E zzw p Z 0 0 Z::R Z z 0 c1q ci z a] ,D FILE: ww HT01 —COVER. E: NOV 2016 ,LE: -m AS SHOWN MING NO. 2 of 6 vv L5...... F.EXISTING UNDFROROUND TO SVE EXISTING HYDRANT 'ELECTRICAL WIRE -EXISTING LEACHATE ue, M px ....... COWEN SYSTEW AND S-A T, OP NH CLOSED',, . . . . . . . . . . . . . . . . . . . . . . . . . ......... .. ........ ­ i 1 .. ... ........ , _j ........... ST NG CULV��T .. ........ j­ EXI' I ............ ........ . ... ......... . -EXISTINGJ REMQ.,VED) EXI Si N G TO BE H EAD XISTIN.G.. EMPLOYEE�, . . . . . . ...... . . .. . ._'. ..\. fLNG A" LANDFILL LIMITS ��FG I N b ........... POWER ONE POLE ...... ..... .. ...... ....... ............ PARKi. r4 ....... . ...... ............ ...... . ........ (3 TRANSFORMERS ............. .. ... ............... ... . ............. .... .............. . . ..... . ....... . . ..... ------- .......... ;, 1vv MAT -EXISTIN)G-, IRRIGATION`— ... .......... .......... . ...... ..... .... ..... .... UTILIZATIO • ........... 'OND L 1 N j� 'CENTER .i. .. .....• EXISTING WEI SlATION . .. s 'S - , ` % .•�`„' , rj ' ♦/,•.. - ° , /r '•- ,,�••y i,, •,.�': .'tn i _ i _ _ j j ..... ...... ..... ....... EXISTING OVERHEAD ;POWER LINE POLE EXISTINQz 4�1 11 N E 67 SEPTIC 0 0 -N ................. . . [STING LA EX DOLL ARE S TA'T 10 WENT -,EXISTING FORMER TREATMENT GA5 F L B UILDING TO 13E REMOVED) I . ....... ... E `nNG 'XIS UNDERGROUN13r," POWER LLNE OR --C�ENEgA EXISING... RIVANN'A SOLID WASTE AUTHORITY.., 00_00_Q0__�_ -OCEL: 07.3 0280Q,, TP: •73/2,8 VERHEAD ....... ...... POWER LIMP "POLE XTaTI N G E (3 TRAN S) SFORKR METER_ 8 EXIISTING 2" MIER EXISTING fi LINIE AND P m­ p f > .... ...... -L LINE "ZERO— DISCHARGE ELECTRICA 'STORMWATER• rr -EXISTI�G (TO BE,,REROUTED) BASIN UNDERGROUND, HONE LINE p f ..... ..... ..... ... lip' --- ---- - --- 1jr P P 130 0 30 60 SCALE FEET GENERAL NOTES: 1. EXISTING CONTOURS ARE BASED ON AERIAL AND GROUND MAPPING PERFORMED BY JAMES H. BELL, JR. (MINERAL, VIRGINIA) ON 2/6/97 AND 7/7/99. 2, THE COORDINATE SYSTEM HORIZONTAL ORIENTATION IS VIRGINIA STATE PLAN GRID -NORTH NAD 27, AND VERTICAL DATUM IS NGVD 29. SEE DRAWING NO. 2 FOR BENCHMARK LOCATIONS, FT X LEGEt4D.., 4A, f; W z EXISTING CONTOURS (INDEX) 0 P� J14 el .. ........ ... ...... ...... ... . ...... Al EXISTING CONTOURS (INTERMEDIATE) A A ilz I- � I / N • I V,,�Y`­ M'ATERI V) P`l/ M At EXISTING ROAD (UNPAVED) w 1�'. All ...... ....... . ... -1ON CENTER .1UffILIZ4,T U.1 EXISTING ROAD (PAVED) AD TO DICK A J1, A=�­SS- R 0 V) WOODS ROAD Z. �pv 1 61 EXISTING TREELINE <•V yl 13 0 Z w cr EXISTING LIMITS OF LANDFILL hi 7 i .... . ...... . EXISTING FENCE ... ... ..... .. I J., ............ . . ... .. EXISTING OVERHEAD POWER LINE 0 V on EXISTING UNDERGROUND POWER LINE YZ ...... -v A ...... PROPERTY h 7b t !J, EXISTING LEACHATE LINE -NDARY .......... .. .... Ld BOU ........ .... .... . ...... ...... ... EY e7 x . ....... EXISTING WATER LINE # LFG UG 00 LFG ...... .... .. t J' ....... EXISTING LANDFILL GAS LINE w EXISTING UNDERGROUND PHONE. LINE •j,y4 E qV ..... . .. . ......... EXISTING PROPERTY LINE '4 ... .... .... EXISTING SEWER/SEPTIC LINE .. . ....... ........ ....... . ..... EXISTING SPOT ELEVATION (FT) fit .. .... 75 FRONT A/, IOU Jr EXISTING MONITORING WELL SETBACK . ...... W op - -- ­tl . .. , J7 .. ... ... .... z . ...... EXISTING BENCHMARK oc it < CRITICAL SLOPES (25% OR STEEPER) ILI . .... ...... . .. ...... .. .. ..... . . 6 100 4p 4()l V - Z )15 Q LLJ z cr as . ...... .. .... ....... ...... . ..... ct� ,J z w a. 11-- Z cf) n W z 0 ( ) z j 0 cr. w U. 0 0 z z uj w z LJ F_ Lu 7) Lij V) cl: 0 W Z CJ cy w 4 > 0 w - w w > 0 W w 0 000 (n 2.j ul) cc C) z Q z > z Lu V) < Z 0) a: < Lu q U) W m5E N Zz w a !Z' UA xPad P12 Z 5: U) CL (9 x 0 Ld Z LL v) Z w z Ooz (0 0 y) 5 w q 0 cn 25-x, M =) I-. 0 z ON (0 au -j CN CADD FILE- SHT02—EXISTING DATE: NOV 2016 F ALE: S OAS SHOWN DRAWING NO. 3 of 6 a- Q w z Lij Q w I— X. W w X VEHICLE EXIT AND JURN--AROUND AREA- 6 0 6 12 SCALE FEET - ENTRANCE ENTRANCE ROAD ROAD Olt k�.cJ 77 _Q V) i�- Lu P Mo () D F- CC 0 >- UJ UJ UJI z ''^^ M LL z LLJ LJ z w F P C) W Q z V) iz �. 0 cm CM ww U� Lu 00 �3: z z w � cs c%t Ln A i -- tR ZW w CL W w LL Z ELu � u� 6 oo (� cr. J 0 CCC Vi n ►z Q i-- r- U 00 N v �� 0 CADD FILE: SHT05-TRANSFE DATE: NOV 2016 SCALE: AS SHOWN DRAWING NO. 1 5 of • of A 1760 COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road,North Wing Charlottesville,Virginia 22902-4596 Phone(434)296-5832 Fax(434)972-4126 December 28,2016 Anthony S.Tomlin,SCS Engineers 2877 Guardian Lane,Suite 1-F Virginia Beach,VA 23452 SDP201600066 New Ivy Solid Waste Transfer Station-Initial Site Plan Mr.Tomlin, The Agent for the Board of Supervisors hereby grants administrative approval to the above referenced site plan. This approval shall be valid for a period of five(5)years from the date of this letter,provided that the developer submits a final site plan for all or a portion of the site within one(1)year after the date of this letter as provided in section 32.4.3.1 of Chapter 18 of the Code of the County of Albemarle,and thereafter diligently pursues approval of the final site plan. In accordance with Chapter 18 Section 32.4.2.8 Early or Mass Grading may be permitted after the following approvals are received: 1. Submittal of a tree conservation checklist with areas for tree preservation identified. 2. Engineering approval of a VSMP plan meeting the requirements of Chapter 17 of the Code of the County of Albemarle. 3. Approval of all easements for facilities for stormwater management and drainage control. The final site plan will not be considered to have been officially submitted until the following items are received: 1. A final site plan that satisfies all of the requirements of section 32.6 of Chapter 18 of the Code. 2. A fee of$1,613. Please submit 10 copies of the final plans to the Community Development Department.The assigned Lead Reviewer will then distribute the plans to all reviewing agencies.Once you receive the first set of comments on the final site plan,please work with each reviewer individually to satisfy their requirements. The Department of Community Development shall not accept submittal of the final site plan for signature until tentative approvals for the attached conditions from the following agencies/reviewers have been obtained: SRC Members: Albemarle County Planning Services(Planner)-3 copies[Paty Saternye ext 3250] Albemarle County Planning Services(ARB)- 1 copy[Margaret Maliszewski ext. 3276] Albemarle County Engineering Services(Engineer)- 1 copy[Emily Cox ext 3565] Albemarle County Information Services(E911)- 1 copy[Andrew Slack ext 3384] Albemarle County Department of Fire Rescue- 1 copy[Robbie Gilmer 434-296-5833] Virginia Department of Transportation- 1 copy[Adam Moore 434-422-9894] Albemarle County Building inspections— 1 copy[Jay Schlothauer ext 3228] Albemarle County Service Authority(ACSA)- 1 copy[Alex Morrison 434-977-4511 ext 116] If you have any questions about these conditions or the submittal requirements please feel free to contact me at Extension 3250,paaternye@albemarle.org. Sincerely, Senior P1 1 FA Lr yip County of Albemarle Department of Community Development 401 McIntire Road, Charlottesville, VA, 22902 Phone 434-296-5832 Fax 434-972-4126 Memorandum To: Anthony S. Tomlin (ttomlin(c�scsenq.com) From: Paty Saternye, Senior Planner Division: Planning Date: December 19, 2016 Updated December 28, 2016 Subject: SDP 201600066 New Ivy Solid Waste Transfer Station — Initial Site Plan The County of Albemarle Planning Division will recommend approval of the plan referenced above once the following comments have been satisfactorily addressed (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.): [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] 1. A site plan meeting all the requirements of section 32.6 of Chapter 18 of the Code. 2. [32.5.2(b)] Provide notes for the maximum height allowed in the RA zone and the proposed height of the building. The maximum height of a building in the RA zone is 35'. The side of the proposed transfer station facing the public road appears to have a height of just under 50'. However, zoning inspections has specified (12/15/2016) that the north side of the building, where the trucks will drop off waste, is considered the "front" of the building. The north elevation appears to be just under 35'. Dimension the height of the elevations on Drawing NO. 6 of 6 and ensure that the elevation considered be the front of the building is no more than 35' height. Any building height above 35' will not meet the RA zone requirements and would be considered a variance from the Zoning Ordinance. 3. [32.5.1(c) & 32.5.2(a)] Provide the dimensions for the boundary(bearing and distances) of the parcel. 4. [32.5.1(c)] Provide a note that specifies all of the yard requirements for RA zones or revise the labels on Drawing No. 2 of 6 to specify that the distances are for the setbacks. 5. [32.5.2(a)] Provide the name of the county and state under the name of the development. 6. [32.5.2(a)] Revise the "Abutting Parcel Information" chart so that 73-27E, owned by Irene B Morris, is listed correctly. 7. [32.5.2(b)] Provide a tally of square footage of uses and the percentage of open space for the whole parcel. 8. [32.5.2(e)] Provide labels identifying whether the existing wooded areas are composed of evergreen, deciduous or a mix of types of trees. 9. [32.5.2(e)] The line which represents existing wooded areas does not appear to be consistent and therefore it is not possible to tell what areas are wooded and what areas are not on the western side of the site. The direction of the line type creates confusion along what appears to be an access road just to the west of the proposed building site. 10. [32.5.2(f)] Provide the locations and names of water courses within the parcel in the key plan on Drawing No. 2 of 6. Page 1 of 3 11. [32.5.2(h)] Provide the boundaries of the flood hazard overlay district areas within the parcel. This could be provided in the key plan on Drawing No. 2 of 6. 12. [32.5.2(i)] Provide the state route number, the right of way lines and width for Dick Wood's Road. 13. [32.5.2(j)] Provide the sizes for all existing water, sewer and drainage lines and facilities. 14. [32.5.2(j) &32.5.2(k)] The proposed sewer line appears to be connecting to an existing leachate line. Revise the sewer line to be a leachate line or show it connecting to an existing sewer line. If the line is changed to a leachate line add a proposed leachate linetype to the legend. 15. [32.5.2(j)] There is what appears to be an existing underground electric and existing water line very close to one another. For part of their length the letters in the lines are not legible. Ensure that the linetypes are able to be read. 16. [32.5.2(k)] Indicate the direction of flow on all storm drainage pipes and watercourses. 17. [32.5.2(I)] Provide the location of any other existing or proposed utilities and utility easements including telephone, cable, electric and gas. Indicate the deed book and page reference for all exiting utility easements located on the property. 18. [32.5.2(n)] Dimension the retaining walls, including their maximum height. 19. [32.5.2(n)] The proposed fence appears to connect to the existing fence in the southeastern corner of the site. However, a portion of the existing fence is located where a proposed stormwater pond is shown. Provide the location of where the proposed fence will connect to the existing fence system. Show where existing fence will be demolished on the existing conditions sheet. 20. [32.5.2(n)] Provide the location and dimensions for any proposed lighting fixtures including wall mounted light fixtures. If there will be any external lighting fixtures a photometric plan will be required with the Final Site Plan. In addition to meeting all lighting requirements a standard lighting note will be required. 21. [32.5.2(n)] There appears to be a significant area of parking that exists on the site that is not shown on the existing conditions or the proposed site layout sheets. Also, there is no parking information or calculation provided on this initial site plan. Provide information on what parking exists, what parking will be removed or remain and the impact this will have on the parking for the whole parcel and not just this immediate proposed site. This information and calculations must include the addition of the new building and any employees who may work there. 22. [32.5.2(n)] Provide the location and dimensions for any proposed road signage. 23. [32.5.2(n)] Provide the location of the gates in the existing fences. 24. [32.5.2(p)] Provide a landscape plan that meets all requirements of section 32.7.9 with the Final Site Plan. Although this is a public use for the purposes of landscaping requirements it will be considered commercial or industrial. Therefore the site plan must meet the landscaping requirements. This includes, but is not limited to, the tree canopy requirements and calculations. 25. [32.5.2(p) 32.7.9.7(a)(3)] It appears that the majority of the existing woods shown on the west side of the site plan area are being removed. Because the site plan does not include the existing conditions further towards the western property line, and because some of the wooded area lines do not seem to be oriented properly, it is uncertain if the proposed building and use will be screened on the western side, towards the RA zoned and residential use adjoining lots. Provide additional information on the wooded areas to the west of the proposed site, showing that they will fully screen the building, containers and use from the adjoining properties or provide screening toward the west side of the site. Page 2 of 3 25. [4.2] It appears that critical slopes will be impacted by the improvements required for the transfer station. Accessways, public utility lines, and stormwater management facilities can be exempt from this requirement provided that the applicant demonstrates that no reasonable alternative location or alignment exists (4.2.6(c)). Demonstrate that there are no reasonable alternative locations for items and improvements impacting the critical slopes areas. It appears that one of the stormwater ponds and a forebay may be able to be moved farther west to reduce the impact to the critical slopes. The access way on the north side of the project appears to be able to be moved further north to avoid the critical slope area to its south. Also, items not specified as possible exceptions (4.2.6(c)) must either be designed to not impact critical slopes or a critical slopes waiver request will be required. The proposed demolition and relocation of the fence in the south east corner of the proposed project, and the proposed screening trees, are not exempt. Either ensure that any critical slopes disturbance caused by the section of the fence removed and replaced, or the area for the proposed landscaping being cleared and trees planted, is completely within the area of disturbance to the critical slopes caused by the exempt items, such as the stormwater pond, or submit a critical slopes waiver request for this disturbance of the critical slopes. 26. [Comment] The existing line work is too light and hard to read. All line work and text must be legible even after the plan is copied or scanned. 27. [Comment] Revise the drawing to have labels and leaders pointing towards the objects they are describing. • On Drawing No. 4 of 6, near the left hand side of the sheet near one of the stormwater ponds, there is a label that says "Proposed Culvert" and a leader, but they are not pointing towards any object. • On Drawing No. 4 of 6, there is a "R50"' label that's leader is not pointing towards the centerline of the road. 28. [Comment] On a previous exhibit for the Ivy Material Utilization Center there was a note that said there was possibly a cemetery located in the general vicinity of the proposed transfer station or its improvements. It has been stated that there has been a study of the site to determine whether a graveyard existed. Specify the outcome of that study. If a cemetery exists, show its location on the existing conditions and site plan sheets of the plan. 29. [Comment] See the attached comments from the other SRC reviewers. Please note that the ACSA comments were not attached prior to the SRC meeting on 12/22/2016 but have been attached to this update. ./ Please contact Paty t nye in the Planning Division by using psaternyealbemarle.orq or 434-296-5832 ext. 3250 for further infoFination. ci Page 3 of 3 Review Comments SDP201600066 Project Name: ew Ivy Solid Waste Transfer Station - Initial Date Completed: vlonday. December 05. 2016 Initial Site Plan I v Reviewer: -Emily Cox DepartmenbDivision?.Agency: iCDD Engineering Reviews Comments: Engineering comments for above referenced plan are completed. They should be in City View and are also listed below_ -Note there is no title (Initial Site Plan) and no professional seal on these plans -The legend and associated line types on Sheet 3 are hard to read. -The topography should be field verified since it is sourced from a year of 1997 and 1998. -Note: Will need more detailed information for the retaining walls at time of final site plan_ -Travel way on the north end seems steep(15%) This will need to be further evaluated at time of final site plan -Note• WPO will have to be submitted and approved before a final site plan can be approved Rev-iew Status. Requested Changes I' Page: 1 County of Albemarle Printed On: 112'16,'2016 01. COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION t601 Orange Road Culpeper,Vlrgrnia 22701 Charles A.Kilpatrick,P.E. Commissioner December 07, 2016 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Patricia Saternye Re: New Ivy Solid Waste Transfer Station- Initial site plan SDP-2016-00066 Review#1 Dear Ms. Satemye: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by SCS Engineers,dated November 01, 2016 and offers the following comments. Land Use 1. Please see Road Design Manual appendix F-Access Management design standards for entrances and Intersections, figure 4-10 commercial entrance design. Provide a right and left turn lane warrant analysis as shown in F-96. 2. Please provide Route number,Speed limit,and Right of Way width on all plan sheets. Please note that the final site plan must show conformance with the VDOT Road Design Manual Appendices B (1) and F, as well as any other applicable standards, regulations,or other requirements. If further information is desired,please contact Willis C. Bedsaul at 434-422-9866. Sincerely 101114,K Gt/la Adam J. Moore, P.E. Area Land Use Engineer Charlottesville Residency WE KEEP VIRGINIA MOVING Patricia Saternye From: Alexander Morrison <amorrison@serviceauthority.org> Sent: Thursday, December 22, 2016 11:09 AM To: Patricia Saternye Subject: RE: SDP 2016-66 Ivy Solid Waste Transfer Station Paty, I have reviewed the submittal.This parcel is listed as limited service in the ACSA's Jurisdictional Area.There is no infrastructure in this area so the existing building are most likely served through well and septic.The applicant shall add notes to the cover page describing the proposed water/sewer service as well and septic. That is the only comment that I have. Since this is limited service will they need to go through the water/sewer waiver process to utilize private utilities? Let me know. Alexander J. Morrison, P.E. Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville,Virginia 22911 (0)434-977-4511 Ext. 116 (C) 434-981-5577 (F)434-979-0698 From: Patricia Saternye [mailto:psaternye@albemarle.org] Sent: Thursday, December 22, 2016 9:31 AM To: Alexander Morrison Subject: RE: SDP 2016-66 Ivy Solid Waste Transfer Station Perfect O. Thanks. Have a wonderful and safe holiday season! Paty Saternye Senior Planner Community Development i,61AtN r ®1 J V i!<ti IH'1 Albemarle County 401 McIntire Road Charlottesville,VA 22902 434-296-5832 ext.3250 psaternye@albemarle.org www.albemarle.org 1 From:Alexander Morrison [mailto:amorrison@serviceauthoritv.orgl Sent:Thursday, December 22, 2016 9:30 AM To: Patricia Saternye<psaternye@albemarle.org> Subject: RE: SDP 2016-66 Ivy Solid Waste Transfer Station Paty, I got your voicemail as well. I was on the phone with contractors so I am sorry I missed your call. I have not completed comments yet, but will try to get through the SRC information today. I will not be at the meeting because the other engineers are off today. I will try to have you something by the end of the day.Thank you. Alexander J. Morrison, P.E. Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville,Virginia 22911 (0)434-977-4511 Ext. 116 (C)434-981-5577 (F)434-979-0698 From: Patricia Saternye [mailto:psaternye@aalbemarle.org] Sent: Thursday, December 22, 2016 9:27 AM To: Alexander Morrison Subject: SDP 2016-66 Ivy Solid Waste Transfer Station Alex, I just wanted to touch base with you on SDP2016-66 Ivy Solid Waste Transfer Station SRC review. I don't think I have received your comments on this SRC submission yet. Since today is the SRC meeting I thought I would reach out to you and see if you are still in process or if I have misplaced comments you already sent me. Thanks, Paty Saternye Senior Planner Community Development • iY�+ct Albemarle County 401 McIntire Road Charlottesville,VA 22902 434-296-5832 ext.3250 psaternve@albemarle.org www.albemarle.org 2 Review Comments SDP201600066 Project Name: ew Ivy Solid Waste Transfer Station - Initial Date Completed: Tuesday. November 22, 2016 Initial Site Plan Reviewer: .Aargaret Maliszewski DepartmentDivision?Agency: CDDARB Reviews Comments: This development is not expected to be visible from the 164 Entrance Corridor- Consequently.ARB review is not - required Review Status: No Objection - - Page: 11 County of Albemarle Printed On: 112116/2016 Review Comments SDP201600066 Project Name: ew Icy Solid Waste Transfer Station - Initial Date Completed: , Monday. November 28. 2016 Initial Site Plan Reviewer: Jerek Bedarf DepartmenbDivisionLAgency: CDD E911 Reviews Comments: ._ Based on plans dated November 1. 2016_ No comments or conditions Review Status: No Objection • Page: 1 County of.Albemarle Printed On: 1 12'1612016 Review Comments SDP201600066 Project Name: ew Ivy Solid Waste Transfer Station -Initial Date Completed: Sunday. November 20. 2016 Initial Site Plan Reviewer: rtobbie Gilmer Department/Division/Agency: 1Fire Rescue _ J Reviews Comments: Based on plans dated 11/1/2016 No comments or objections. Review Status: No Objection v i Page. 1 County of Albemarle Printed On: 112'1612016 Review Comments SDP201600066 Project Name: ew Ivy Solid Waste Transfer Station -Initial Date Completed: Thursday. November 17,2016 Initial Site Plan Reviewer. ay Schlothauer Department/DivisioniAgency: CDD Inspections Reviews Comments: Based on plans dated November 1. 2016. No comments or conditions Review Status: [No Objection ` 1 Page: 11 j County of Albemarle Printed On: 112'16?2016 Patricia Saternye From: Mazurowski,Alan (VDH) <Alan.Mazurowski@vdh.virginia.gov> Sent: Monday, December 19, 2016 12:02 PM To: Patricia Saternye Subject: Initial Site Plan, New Ivy Solid Waste Transfer Station,SDP201600066 Ms.Saternye, As requested by your department, I have reviewed the initial site plan for the New Ivy Solid Waste Transfer Station. I have no concerns regarding water and sewer as it appears connections will be made to public utilities. Recommendation: Approval Please let me know if you have any questions. Alan Alan Mazurowski Environmental Health Supervisor Thomas Jefferson Health District 1138 Rose Hill Drive Charlottesville,VA 22903 434-972-4306 office 434-972-4310 fax 1