Loading...
HomeMy WebLinkAboutWPO201300032 Plan - As-built 2022-08-05 (2)PLANTING SCHEDULE TABLE VICINITY MAP WEIR Impervious Core* SCALE: 1 "=2000' F •a pP•-anklin +'W'nd $ AREA OF AS BUILT wnm camvy'°'ona' �\,J Horne, °^•�r '"arn°. �pe Fonuna e� -y'P;m,ano w.v 8 w eP�e 6 Rd ® ® -..Rtl O .� O ROMm Ra 6 ♦,F^" VemW Or Mo E 9 9p 9 e 9�,yyQ Jn NOeMCN Or R F a SY H. en Rd aH Rmren. canape co-comoa a HiY Centlo4 CLEAN —OUT W/WATERTIGHT R' , CAP 'TOP OF BERM B10FILTER EARTHFILL L 4" NON —PERFORATED PVC PIPE @ 1% MIN, SLOPE *Impervious core shown for informational purposes only. Final design to be provided by geotechnical engineer. R51 SEE TOP 431.5Y BERM WEIF D� ETAIL ELEV= � 01 N O PROVIDE PIPES ACROSS ENTIRE WIDTH AT 20 FT O.C. Bio—Filter Sizing Calculations: DA—BF #1 Impervious Area: 22,500 sf. Bio—Filter Area Required: 22,500 X 5% = 1,125 sf. Area Provided = B&5 a� 1,248 sf• Bio—Filter Weir Sizing Calculations: DA—BF #1 Drainage Area = 1.145 Acres c=0.57; Tc=7 Min; 1(10)=6.5; 1(100)=8.4 Q(10)=4.24 cfs; 0(100)=5.48 cfs Weir Calculation (Weir Length = 4'): 10 Year: 4.24 cfs=3.33(4')(H^J) —> H= 0.47' 100 Year: 5.48 cfs=3.33(4')(H" J) —> H= 0.55' 3'S \— LOAM OR GRANULAR 4" PERFORATED PVC PIPE O 1% MIN, SLOPE Note: For BF-1, Extend 4' wide by 1' deep rip —rap channel to stream. Refer to sheet SP8 of the site plan for final grading. 50% SAND/30% TOPSOIL/ 20% LEAF MULCH (SAND: 0.02"-0.04", ASTM C33 FINE) \` FILTER FABRIC UNDERDRAIN GRAVEL (AASHTO M43, 1/2"-1") WRAPPED IN FILTER FABRIC APPROVED by the Albemarle County Community Development Department Date 08/10/2022 File WP0201300032 2 BIO-FILTER SCHEMATIC SW15 NOT TO SCALE BLANDSCAPING�P MEN - ed Maple (Acer oil rubrum) moll Njy � �J�i ■ • • Y• -•- - - - -•- WFA LT SHRUBS & FS- LATE BONESET EUPATORIUM SEROTINUM JOHNSON GRASS (SORGHUM HALEPENSE) CHINESE BUSHCLOVER (LESPEDEZA CUNEATA) COMMON MUGWORT (ARTEMISIA VULGARIS) YELLOW CROWNBEARD (VERBESINA OCCIDENTALIS) FIELD THISTLE (CIRSIUM DISCOLOR) BEEFSTEAK PLANT (PERILLA FRUTESCENS) WINTER JASMINE (JASMINUM NUDIFLORUM) UNDERDRAIN 4" NON —PERFORATED PVC PIPE BERM Grass Weir 1. THE ORIGINAL DESIGN PLANS AND PROFILES USED FOR THIS AS -BUILT SOURCED FROM'FINAL EROSION & SEDIMENT CONTROL AND STORMWATER MANAGEMENT PLAN FOR CASCADIA BLOCKS 4-7" BY MICHAEL MYERS, P.E., DOMINION ENGINEERING, DATED SEPTEMBER 9, 2014. 2. FIELD WORK WAS COMPLETED ON JULY 29, 2022. 3. DENOTES AS -BUILT INFORMATION 4. THIS REVIEW DOES NOT IMPLY IN ANY WAY; a. THAT INSPECTIONS WERE MADE DURING CONSTRUCTION, UNDERDRAIN b. TO THE QUALITY OF THE WORK, OR 4" PERFORATED C. TO ANY ELEMENT OR STRUCTURE NOT VISIBLE OR DEPICTED ON THE PVC PIPE PHYSICAL SURVEY. CLEAN —OFF (TYP) TYPICAL PLANTING SCHEMATIC NOT TO SCALE I, DUSTIN GREENE, HEREBY CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE, THIS AS -BUILT PLAN REPRESENTS THE ACTUAL CONDITION OF THE STORMWATER FACILITY, AND THAT ALL ASPECTS OF THE STORMWATER FACILITY WERE CONSTRUCTED SUBSTANTIALLY IN ACCORDANCE WITH THE APPROVED DESIGN PLANS, UNLESS NOTED OTHERWISE. T°rya r°°n C/ UU I�1 C) U�z rn rn � �w wNo0 " a : Q� U Q o 2 a.z �> °N 0 r n W o�Pm z O N M o 05 (N H Z � LU rn_1a �L v a w N 0 W z 0 cn U Lu w 0 Ln Z O Ln w m w 0 0 Z o}4$SVTa of y�+c iy Dustin E. Greene Lic. No. Q A,o 55833 �g8lopeti. 6� I� a � z Cn z�C�� a a V U w m O m ~ J a a J w TD O m m 00 — z LLJ a Q J 0 LL cn Q x O >U�o m v� a z Qz U DRAFTER: CS DESIGNER: DG PRODUCTION ZD DATE: 08/05/2022 SCALE: AS SHOWN JOB: CASCADIA FILE: 12.0065 SHEET: � OF 1