CLE202200124 Correspondence 2022-09-14
SUITE EXIT SEPARATION - SUITE A: O LONGEST OVERALL DIAGONAL: 136' 136' X 113 = 46' MINIMUM SEPARATION REQUIRED © ACTUAL EXIT SEPARATION: 85' COMPLIANT EXIT# WIDTH -XX" CAPACITY: ### EXIT CAPACITY PATH OF TRAVEL EXIT#2 1 WIDTH: 34" CAPACITY: 226 CAPACITY I I I I L� El 3 SUITE EXIT SEPARATION - SUITE B: ONLY SINGLE EXIT REQUIRED: *OCCUPANT LOAD = 16 (< 49) = COMPLIANT *EXIT ACCESS TRAVEL DISTANCE = 43' (< 75') = COMPLIANT EXIT SEPARATION ANALYSIS El 51 LEGEND CHANGE IN DIRECTION / POINT OF DECISION DISTANCE TO AN EXIT COMMON PATH OF TRAVEL PLUMBING FIXTURE REQUIREMENT- 1ST FLOOR FIXTURE TYPE / REQUIREMENT OCCUPANCY ACTUAL FIXTURES REQUIRED FIXTURES PROVIDED NOTES CLASSIFICATION OCCUPANT LOAD WATER CLOSET 2 REQU'D. FOR FIRST 50 AND 1 PER 50 FOR 182: 2.82 MALE REMAINDER EXCEEDING 50 - 1 PER 100 BUSINESS 91 MALE 2.82 FEMALE 91 FEMALE 2: 0.01 MALE 1 PER 100 STORAGE 1 MALE 0.01 FEMALE 1 FEMALE MEN: 1 PER 125 44' 0.18 MALE WOMEN: 1 PER 65 ASSEMBLY 22 MALE 0.34 FEMALE 22 FEMALE TOTAL FIXTURES: MALEFEMALE MALEFEMALE COMPLIANT 4 4 LAVATORY 2 REQU'D. FOR FIRST 80 AND 1 PER 80 FOR THE 182: REMAINDER EXCEEDING 80 BUSINESS 91 MALE 2.14 MALE 91 FEMALE 2.14 FEMALE 2: 0.01 MALE 1 PER 100 STORAGE 1 MALE 0.01 FEMALE 1 FEMALE 44: 1 PER 200 ASSEMBLY 22 MALE 0.11 MALE 22 FEMALE 0.11 FEMALE TOTAL FIXTURES: 3 MALE 3 FEMALE 4 MALE 4 FEMALE COMPLIANT DRINKING FOUNTAIN EXCEPTION IF PROVIDED IN COOLER IF NOT MORE THAN 50% OF REQUIRED FIXTURES BUSINESS 182 1.82 1 PER 1,000 STORAGE 2 0.00 1 PER 500 ASSEMBLY 44 0.09 TOTAL FIXTURES: 2 2* COMPLIANT *ACCESSIBLE FILTERED WATER IS AVAILABLE IN THE TENANT'S COFFEE AREA. PLUMBING FIXTURE ANALYSIS EXIT CAPACITY SCHEDULE - 1ST FLOOR EXIT STAIR WIDTH CAPACITY FACTOR .2 LEVEL COMPONENTS CAPACITY FACTOR.15 EXIT CAPACITY EXIT #1 220 68" 453 453 EXIT #2 220 34" 226 226 EXIT #3 220 34" 226 226 GRAND TOTAL 905 MINIMUM WIDTH PER PERSON: 1. LEVEL (34" DIVIDED BY .15 = 226 PERSONS @ EA. EXIT) 2. STAIR (44" DIVIDED BY .2 = 220 PERSONS @ EA. EXIT) - GOVERNS OCCUPANT LOAD SCHEDULE - 1ST FLOOR SYMBOL NAME AREA(USF) LOAD FACTOR (SF/PERSON) ACTUAL OCCUPANT LOAD GROSS FLOOR AREA - (LESS MECHANICAL SHAFTS) 19,230 SF TENANT USABLE AREA 7,627 SF TENANT AREA - BUSINESS 6,536 SF 100 GROSS SQ. FT / PERSON 66 TENANT AREA -ASSEMBLY 657 SF 15 NET SQ. FT / PERSON 44 STORAGE 434 SF 300 GROSS SQ. FT / PERSON 2 TENANT OCCUPANT LOAD 112 REMAINING GROSS SF - BUSINESS 11,603 SF 100 GROSS SQ. FT / PERSON 117 TENANT FLOOR OCCUPANT LOAD 229 OCCUPANCY CLASSIFICATION: A. CLASSIFICATION TYPE: BUSINESS B. CONSTRUCTION AREA: 1ST FLOOR EXIT CAPACITY > TENANT OCCUPANCY LOAD - COMPLIANT ASD I SKY 3030 Clarendon Boulevard Suite 350 Arlington, VA 22201 T 703.876.9600 F 703.876.1700 www.asdsky.com ATLANTIC UNION BANK 1ST FLOOR RENOVATION 1658 STATE FARM BLVD CHARLOTTESVILLE, VA 22911 This drawing is the property of Associated Space Design, Inc. and is not to be reproduced or copied in whole or part. It is not to be used on any other project and is to be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Desiqn, Inc. 2016 0 09.02.22 Issue for Bid & Permit A 08.26.22 75% Review NO: DATE: REMARKS: REVISIONS: DRAWING TITLE. 1ST FLOOR LIFE SAFETY PLAN WE a 1 1 1ST FLOOR - LIFE SAFETY PLAN o' 2' a' a' 12' 1 /8" = 1'-0" 12 OCCUPANCY LOAD 71305.00 MW/CP 09.02.22 LSm01 JR 00 LP LO co N N O N N GENERAL DEMOLITION NOTES: 6.2 CAREFULLY REMOVE THERMOSTAT AND KEEP WIRING TO T-STAT INTACT. COIL -UP WIRING AND PLACE WIRE AND THERMOSTAT BOX FOR RE -USE. 1.0 DEMOLITION CONSISTS OF PERFORMING ALL DEMOLITION OF EXISTING CONSTRUCTION WHICH IN ITS PRESENT POSITION WILL INTERFERE WITH THE COMPLETED NEW CONSTRUCTION AND TO PERFORM ANY OTHER CUTTING OR PATCHING OF EXISTING CONSTRUCTION AS SHOWN ON THE DRAWINGS. EACH SPECIFIC ITEM OF CUTTING, PATCHING OR FITTING IS NOT NECESSARILY DESCRIBED INDIVIDUALLY HEREIN. ABSENCE OF A SPECIFIC INSTRUCTION FOR CUTTING, PATCHING OR FITTING SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY TO PERFORM AS REQUIRED COMPLETING THE WORK. 1.1 CODED NOTES FOR WORK DESCRIBED ON THE PLAN SHALL REFER TO THE ENTIRE ROOM OR SPACE WHERE THE NOTE IS LOCATED UNLESS NOTES OTHERWISE. 2.0 CLEAN BASE BUILDING EXTERIOR WALL- GLASS, MULLIONS, SILLS, BLINDS, ETC OF DRIPS, SPILLS AND DEBRIS. REPAIR ANY DAMAGE CAUSED BY DEMOLITION. 3.0 ALL EXISTING DOORS, FRAMES, DOOR HARDWARE, LIGHT FIXTURES, MECHANICAL DIFFUSERES, MECHANICAL CONTROLS, EXIT SIGNS, FIRE ALARM DEVICES AND FIRE EXTINGUISHERS AND CABINETS NOT BEING REUSED FOR THIS PROJECT SHALL BE REMOVED AND DELIVERED TO THE LANDLORD. CONSULT WITH ARCHITECT FOR VERIFICATION. RELOCATION OF ITEMS INVOLVED IN THE WORK IS SUBJECT TO THE CONTRACTOR'S ABILITY TO DO SO WITHOUT PERMANENTLY DAMAGING OR MARRING THE ITEMS TO BE RELOCATED. IF THE CONTRACTORS IS UNABLE TO RELOCATE THE ITEMS AS PRESCRIBED. SUBSTITUTION OF NEW MATERIAL IN LIEU OF RELOCATION IS ACCEPTABLE CONTRACTOR MAY ELECT TO USE NEW MATERIALS TO MATCH EXISTING IN LIEU OF RELOCATION AT HIS OWN CONVENIENCE FOR NO ADDITIONAL COST. 3.1 ALL MATERIALS TO BE RE -USED OR RETURNED SHALL BE GROUPED AND STACKED NEATLY IN ONE LOCATION. PROTECT ALL ITEMS FROM DAMAGE. IF ITEMS REMOVED ARE NOT REQUIRED BY EITHER LANDLORD OR TENANT THEY SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND REMOVED FROM THE SITE AS WORK PROGRESSES. 4.0 PATCH ALL FLOOR, CEILING AND WALL SURFACES AS WELL AS ALL ADJACENT SURFACES EFFECTED BY DEMOLITION WITH SIMILAR MATERIALS AS NECESSARY TO ACHIEVE UNIFORM, NEW APPEARANCE (I.E. GWB PERIMETER WALLS, DEMISING WALLS, CORE ETC). PATCHES SHALL BE INPERCEPTIBLE. 5.0 IN ALL AREAS WHERE DEMOLITION (REMOVAL OF PARTITIONS, ETC.) CAUSES UNEVENNESS IN THE FLOOR. THE CONTRACTOR SHALL REPAIR OR PATCH THE FLOOR TO RECEIVE THE SPECIFIED FLOORING. 6.0 DEMOLITION INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING: PARTITIONS; ACOUSTIC CEILING SYSTEM. 6.1 REMOVAL OF EXISTING PARTITIONS, INCLUDING DOORS, FRAMES, AND THERMOSTATS,ELECTRICAL WITHIN PARTITIONS SHALL BE REMOVED AS INDICATED ON THE DRAWINGS. 5 1 GENERAL NOTES NO. I DEMOLITION PLAN NOTE 6.3 ALL EXISTING DOORS DESIGNATED FOR REMOVAL INCLUDING FRAMES SHALL BE REUSED WHERE THE SAME TYPE DOOR IS APPLICABLE UNO. ALL REUSED DOORS TO BE REFINISHED / REPAINTED AS SPECIFIED WITH IMPERFECTIONS REPAIRED. ALL EXISTING HARDWARE SHALL BE RETAINED FOR REUSE AS NOTED IN THE DEMOLITION PLAN. 6.4 CEILING - CEILING PLANS NOTE ITEMS TO BE SALVAGED, RELOCATED AND/OR RE- USED. NOTIFY ARCHITECT IF ITEMS INDICATED TO BE RE -USED ARE DAMAGED. 6.5 FINISHES A.REMOVE EXISTING WALLCOVERINGS AND ADHESIVE U.N.O. &REMOVE EXISTING CARPET ADHESIVE, TRANSITION STRIPS, TACK STRIPS AND BASE LINO C.REMOVE EXISTING VCT ADHESIVE, TRANSITION STRIP AND BASE LINO 6.8 HVAC A.SALVAGE FOR REUSE DIFFUSERS (INCLUDING SLOT DIFFUSERS) AS NOTED ON CONSTRUCTION/FLOOR AND WALL FINISH PLAN STANDARDS. 6.8 PLUMBING - REMOVE A SUPPLY AND DRAIN LINES BACK TO RISER AND CAP. DETERMINE FEASIBILITY OF RE -USING EXISTING SUPPLY AND DRAIN LINES PER NEW CONSTRUCTION. NOTIFY ARCHITECT OF DECISION TO RE -USE BEFORE PROCEEDING. 6.9 SPRINKLER - REFER TO MECHANICAL DRAWINGS FOR SPECS. 6.10 MISCELLANEOUS REQUIREMENTS IF CONTRACTOR DISCOVERS EXISTING CONDITIONS WHICH ARE NOT INDICATED ON THE DRAWINGS. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY BOTH VERBALLY AND IN WRITING PRIOR TO PROCEEDING WITH THAT PORTION OF THE WORK. 7.0 DEBRIS REMOVAL CONDUCT DEMOLITION OPERATION AND THE REMOVAL OF DEBRIS AND EQUIPMENT TO INSURE MINIMUM INTERFERENCE WITH EXISTING BUSINESS OPERATION. CONSULT WITH BUILDING OWNER FOR ANY RULES AND REGULATIONS REGARDING HOURS, DUMPSTERS AND REMOVAL. ELEVATOR MUST BE PROTECTED AND TIMING MUST BE COORDINATED WITH BULIDING OWNER. INSURE PROTECTION OF PERSONS AROUND THE DEMOLITION AREA. USE TEMPORARY ENCLOSURES AND OTHER SUITABLE METHODS TO LIMIT THE AMOUNT OF DUST AND DIRT RISING AND SCATTERING IN THE AIR TO THE LOWEST PRACTICAL LEVEL. CONTRACTOR SHALL KEEP DEMOLITION DEBRIS OUT OF THE BUILDING CORRIDORS. DEBRIS RESULTING FROM THE DEMOLITION AND DEMOLITION SHALL BE REMOVED FROM THE BUILDING SITE ON A DAILY BASIS. 1 REMOVE PLUMBING FIXTURE AND CAP WATER LINE. ALL ASSOCIATED PIPES SHALL BE DRAINED, REMOVED AND DEMOLISHED BACK TO RISER. INSTALL VALVE AT RISER. ALL WORK TO REMOVE WATER LINES SHALL BE COORDINATED WITH LANDLORD. 2 CAREFULLY REMOVE LIGHT FIXTURE AND SAVE FOR REUSE; REFER TO REFLECTED CEILING PLAN. 3 DEMOLISH AND REMOVE ALL MILLWORK, INCLUDING COUNTERTOP, BASE, CABINETRY, SHELVING, ETC. 4 REMOVE ALL FLOORING, BASE AND ADHESIVE RESIDUE, TYPICAL, U.N.O. 5 PROTECT AND SAVE BEIGE 12X12" TILE IN THIS AREA THROUGHOUT DEMOLITION. 6 DEMOLISH AND DISCARD ALL EXISTING WALLCOVERING AND CHAIR MOULDINGS, TYPICAL. 7 CAREFULLY DEMOLISH AND DISCARD DOOR KNOB; REFER TO CONSTRUCTION PLAN FOR NEW HARDWARE. 8 DEMOLISH AND DISCARD WALL MOUNTED SINK, FAUCET AND PAPER TOWEL DISPENSER. REMOVE AND SAVE WALL MIRROR AND WALL MOUNTED SOAP DISPENSER; REFER TO ENLARGED RESTROOM PLANS FOR NEW LOCATION. 9 DEMOLISH AND DISCARD FURRED PARTITIONS AS SHOWN. 10 DEMOLISH AND DISCARD EXISTING STOREFRONT. 11 GC TO PROTECT WINDOW BLINDS FROM DUST/DEBRIS THROUGHOUT DEMOLITION, TYPICAL. 12 GC TO PROTECT ALL FLOORING THROUGHOUT DEMOLITION, U.N.O. GC TO PATCH AND REPAIR NEW FLOORING AS REQUIRED WITH NEW CONSTRUCTION, TYPICAL. 13 DEMOLISH AND DISCARD EXISTING MOP SINK AND CAP WATER LINE. ALL ASSOCIATED PIPES SHALL BE DRAINED, REMOVED AND DEMOLISHED BACK TO RISER. INSTALL VALVE AT RISER. ALL WORK TO REMOVE WATER LINES SHALL BE COORDINATED WITH LANDLORD. 14 ELECTRICAL PANEL AND PHONE BOARD TO BE RELOCATED; REFER TO MEP DRAWINGS. 4 1 CODED NOTES 1. PRIOR TO STARTING ANY WORK, THE CONTRACTOR SHALL REVIEW CONSTRUCTION GUIDELINES AS PREPARED BY THE BUILDING OWNER AND AGREE ON A LOCATION FOR THE SUPERINTENDENT'S FIELD OFFICE, DESIGNATED RESTROOMS, WORKING HOURS, SYSTEMS SHUT DOWNS, DUMPSTER LOCATIONS/LEED PROCEDURES, ETC. THESE RULES SHALL BE POSTED ON THE JOB SIGHT AT ALL TIMES. 2. THE CONTRACTOR SHALL PROTECT ALL EXISTING TO REMAIN AREAS PRIOR TO DEMOLITION AND NEW WORK. 3. CONTRACTOR SHALL REVIEW METHOD FOR PROTECTION OF FREIGHT ELEVATOR(S), PATH OF TRAVEL AND CONSTRUCTION AREA WITH BUILDING OWNER FOR APPROVAL. 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE G.C. WITH TEMPORARY POWER DURING DEMOLITION. 5. THE CONTRACTOR SHALL VISUALLY INSPECT ALL EXISTING CONDITIONS AND COORDINATE ANY OUTSTANDING DEMOLITION ISSUES WITH THE ARCHITECT AND ENGINEER PRIOR TO BEGINNING WORK. ANY WORK COMPLETED PRIOR TO COORDINATION AND FOUND TO BE INSUFFICIENT/INCORRECT WILL BE REPAIRED AT THE COST OF THE CONTRACTOR. 6. BASE BUILDING STAIRS ARE NOT IN SCOPE. 7. GC IS RESPONSIBLE FOR QUANTIFYING ALL ITEMS IN SCOPE. 8. ITEMS TO PROTECT AND SAVE: -SUITE ENTRY DOOR AND ASSOCIATED HARDWARE -SPRINKLER SYSTEM AND HEADS -EXTERIOR WALLS -POWER/DATA DROPS AT EXTERIOR AND DEMISING WALLS -MINI BLINDS -CORE WALLS, STAIR DOORS, AND FRAMES -EXIT SIGNS, FIRE STROBES, AUDIBLE DEVICES, FIRE HOSE CABINETS -WASTE AND VENT STACKS -WET STACKS 3 1 GENERAL TYPICALS 9. CONTRACTOR SHALL DEMOLISH AND DISCARD THE FOLLOWING THAT IS NOT LOCATED IN CORE AREAS: -FLOORING, WALL BASE, AND THRESHOLDS U.N.O. -ALL CABLING TERMINATED WITHIN THE SUITE -DOOR BELLS AND ASSOCIATED SPEAKERS -ALL SECURITY CAMERAS, CARD ACCESS CONTROLS, ETC. 10. CONTRACTOR SHALL MAINTAIN EXIT ROUTES, ENTRANCES, AND EXITS THROUGHOUT DEMOLITION OPERATION. EXITS SHALL NOT BE BLOCKED BY DEBRIS. 11. DEMOLISH AND REMOVE ALL EXISTING POWER/COMMUNICATION AND WALL - MOUNTED DEVICES U.N.O.: TELE/DATA RECEPTACLES, CABLING, CONDUITS, ETC. DEMOLISH CABLES BACK TO THEIR SOURCE, U.N.O. 12. PATCH AND REPAIR EXISTING TO REMAIN PARTITIONS AS REQUIRED WHERE ADJOINING CONSTRUCTION WAS DEMOLISHED. 13. PATCH, SAND AND PREP PERIMETER WALLS FOR FUTURE PAINT FINISH. 14. CONTRACTOR SHALL REPAIR ANY DAMAGED INSULATION AS A RESULT OF DEMOLITION. SYMBOL DESCRIPTION EXISTING PARTITION TO REMAIN - - - - - - - EXISTING PARTITION TO BE DEMOLISHED. EXISTING DOOR TO BE REMOVED. U EXISTING DOOR TO REMAIN. EXISTING POWER AND TELE/DATA RECEPTACLES T 7 4P 1P EXISTING EXIT SIGN EXISTING SWITCH lit`■ EXISTING WORKSTATION JUNCTION BOX EXISTING BLANK PLATE AREAS NOT IN SCOPE REMARKS D - DEMOLISH AND DISCARD R - REMOVE AND RELOCATE E - EXISTING TO REMAIN D - DEMOLISH AND DISCARD R - REMOVE AND RELOCATE E - EXISTING TO REMAIN D - DEMOLISH AND DISCARD R - REMOVE AND RELOCATE E - EXISTING TO REMAIN D - DEMOLISH AND DISCARD R - REMOVE AND RELOCATE E - EXISTING TO REMAIN DEMOLISH AND DISCARD - PATCH AND REPAIR ASD I SKY 3030 Clarendon Boulevard Suite 350 Arlington, VA 22201 T 703.876.9600 F 703.876.1700 www.asdsky.com ATLANTIC UNION BANK 1ST FLOOR RENOVATION 1658 STATE FARM BLVD CHARLOTTESVILLE, VA 22911 This drawing is the property of Associated Space Design, Inc. and is not to be reproduced or copied in whole or part. It is not to be used on any other project and is to be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Desiqn, Inc. 2016 0 09.02.22 Issue for Bid & Permit A 08.26.22 75% Review NO: DATE: REMARKS: REVISIONS: DRAWING TITLE. 1ST FLOOR DEMOLITION PLAN III a 1 1 1 ST FLOOR -DEMOLITION PLAN 0' 2' 4' 8' 12' 1/8" = 1'-0"I 2 1 LEGEND 71305.00 MW/CP 09.02.22 JR AD1■01 LO co N N O N N GENERAL REQUIREMENTS 1.0 THOROUGHLY FIELD VERIFY CONDITIONS PRIOR TO COMMENCING WORK / PRICING ENSURE FIELD CONDITIONS, DIMENSIONS AND QUANTITIES ARE CONSIDERED IN PREPARATION OF SHOP DRAWINGS AND SUBMITTALS. 1.1 VERIFY PENETRATIONS THROUGH PARTITIONS (SUCH AS DUCTWORK, ETC) TO ENSURE THATADEQUATE BRACING AND REINFORCEMENT ARE PROVIDED. 1.9 DIMENSIONS: 1.9.1 DO NOT SCALE FROM THESE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER GRAPHIC PRESENTATION. DETAIL DIMENSIONS TAKE PRECEDENCE OVER PLAN DIMENSIONS. 1.2 PROVIDE LABOR AND MATERIAL AS REQUIRED FOR WORK WHICH MAY NOT FALL INTO JURISDICTION OF A SPECIFIC TRADE BUT IS REQUIRED FOR PROPER JOB EXECUTION AND COMPLETION OF CONSTRUCTION. 1.3 DETERMINE AVAILABILITY OF ALL MATERIALS. ANY DELIVERY SCHEDULE THAT MAY CAUSE COORDINATION PROBLEMS DURING THE CONSTRUCTION SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AS EARLY AS POSSIBLE, FOR REEVALUATION OF PRODUCT SPECIFICATION. GENERAL PARTITION NOTES: 1.4 REFER TO GENERAL PARTITION DETAILS FOR TYPICAL PARTITION INFORMATION 1.5 PARTITIONS LOCATED ABOVE DOORS SHALL BE OF SAME CONSTRUCTION AS THE ADJACENT PARTITION. 1.6 CAULK GAPS WHERE INTERSECTIONS OF CONSTRUCTION ELEMENTS ARE NOT CRISP AND CONSISTENT. COORDINATE CAULKING & SEALING WITH SPECIFICATIONS SHEET OR MANUAL, INSTALL PER MANUFACTURERS INSTRUCTIONS. 1.7 DOOR AND FRAMES SHALL BE SCRIBED TO THE FLOOR CONDITIONS. 1.8 VERIFY EXISTING WALL / DEMISING WALL / CORE WALL CONSTRUCTION AND MATERIALS BEFORE INFILLING AND PATCHING ANY OPENING TO MEET REQUIRED FIRE RATINGS. 5 1 GENERAL NOTES 11 3 NO. I PARTITION PLAN NOTE 1 PROVIDE 3/4" FRT WOOD BLOCKING AT ALL WALL -MOUNTED MILLWORK OR SIGNAGE AS NOTED. REFER TO ELEVATION FOR EXTENT. 2 PROVIDE 3/4" FRT WOOD BLOCKING AT ALL WALL -MOUNTED DISPLAYS AS NOTED. REFER TO ELEVATION FOR REQUIRED SIZE AND LOCATION. 3 NEW PARTITION WIDTH AND CONSTRUCTION TO MATCH ADJACENT WALL WIDTH AND CONSTRUCTION, TYPICAL. 4 SIGNAGE TO BE PROVIDED TO DIRECT OCCUPANTS TO ACCESSIBLE RESTROOM LOCATIONS. 5 FURR OUT PARTITION AS REQUIRED FOR PLUMBING FIXTURES; REFER TO ENLARGED RESTROOM PLANS FOR HOLD DIMENSIONS. 6 RELOCATED DOOR TO HAVE LOCKING MECHANISM. 7 BOBRICK B-239 UTILITY SHELF TO BE INSTALLED; 80" AFF TO BOTTOM OF SHELF. CONFIRM HEIGHT WITH ARCHITECT PRIOR TO INSTALLATION. 8 WALL TO BE LEVEL 5 FINISH; REFER TO FINISH PLAN FOR EXTENT. CODED NOTES 1. ALL PARTITIONS TO BE AS FOLLOWS U.N.O. 2. DOORS SHOULD BE LOCATED AS FOLLOWS LINO 1--6" I. ---iCLR MIN PUL SIDE PUSH SIDE T - 0".4 CLR. MIN GENERAL PLAN TYPICALS 1.9.2 IMMEDIATELY NOTIFY ARCHITECT OF ANY DIMENSIONAL DISCREPANCIES FOUND BETWEEN THE SITE CONDITIONS AND THE DRAWINGS. NO DIMENSIONS SHALL BE ALTERED WITHOUT THE APPROVAL OF THE ARCHITECT. 1.9.3 ALL VERTICAL DIMENSIONS SHALL BE TAKEN FROM A "BENCH MARK" OR OTHER SIMILAR GUIDE ESTABLISHED PRIOR TO THE START OF CONSTRUCTION. HIGH POINTS, LOW POINTS, IRREGULARITIES IN FLOOR SLAB WHICH COULD AFFECT FABRICATION / INSTALLATION, WORK OF OTHER TRADES OR VENDORS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. 1.10 MATERIALS: 1.10.1 INSTALL MOISTURE -RESISTANT GYPSUM BOARD AT AREAS EXPOSED TO MOISTURE INCLUDING, BUT NOT LIMITED TO, TOILETS, BREAKROOM COUNTERS AND OTHER LOCATIONS NEAR WATER LINO. 1.10.2 ALL NECESSARY WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED. COORDINATE SETTING AND PLACEMENT OF THESE ELEMENTS AND ENSURE THAT LOCAL CODE / BUILDING REQUIREMENTS ARE MET. 1.10.3 BLOCKING MAY NOT BE COMPLETELY ILLUSTRATED ON DRAWING. GOOD CONSTRUCTION PRACTICE SHALL GOVERN. 1.10.4 INTERNAL WOOD BLOCKING SHALL BE PROVIDED FOR STURDY ANCHORAGE AT INTERSECTIONS OF GLASS SIDELITES AND PARTITIONS AND ADJACENT DRYWALL CONSTRUCTION. 3. ALL PARTITIONS TO BE CENTERED ON CURTAINWALL MULLION AND OFFSET FROM KNEE WALLAS SHOWN LINO II I I I I II _-=J I � I o EXISTING CL WINDOW MULLION 1O CODED NOTE TYPE I PARTITION DESCRIPTION I DETAIL NO./ REMARKS 2CW WALL TYPE 2CW: NON -RATED WOOD STUD WALL I 1/A7.01 EXISTING PARTITION NEW PARTITION PARTITION TYPE NOTE 1A DOOR & FRAME TYPE A HARDWARE SET ASD I SKY 3030 Clarendon Boulevard Suite 350 Arlington, VA 22201 T 703.876.9600 F 703.876.1700 www.asdsky.com ATLANTIC UNION BANK 1ST FLOOR RENOVATION 1658 STATE FARM BLVD CHARLOTTESVILLE, VA 22911 This drawing is the property of Associated Space Design, Inc. and is not to be reproduced or copied in whole or part. It is not to be used on any other project and is to be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Desiqn, Inc. 2016 0 09.02.22 Issue for Bid & Permit A 08.26.22 75% Review NO: DATE: REMARKS: REVISIONS: DRAWING TITLE: 1ST FLOOR CONSTRUCTION PLAN 1 1 1 ST FLOOR -CONSTRUCTION PLAN o' r a' 81 1 r 1 /8" = V-0" 1 2 NOT IN SCOPE LEGEND 71305.00 MW/CP 09.02.22 Al mOl JR LO M _LO M N N O N N