HomeMy WebLinkAboutWPO200500012 Bond Reduction 2022-09-15�q oe nt 401 McIntire Road, North Wing
Charlottesville,VA22902-4579
County of Albemarle Telephone: 434-296-5832
COMMUNITY DEVELOPMENT DEPARTMENT WWW.ALBEMARLE.ORG
VSMP Bond Inspection Letter
Project title: Charlottesville Self Storage at Crozet
Project file number: WP0201500020 (WP02005-00012; WP0201500085)
Owner or rep.: Jo Higgins [ musxit@aol.com ]
Inspection date: 14-Sep 2022 (+ Additional dates)
Date of reduction: 15-Sep 2022
Inspector/Compliance Mgr: Mark Hopkins, Dan Ratzlaff
Bond Reduction Reviewer: John Anderson
Dear Jo,
We received your WPO bond inspection request for WP0201500020 (WP02005-00012). The bond can
be reduced to $13,300 (ESC to $3,600; SWM to $9,700). Items 1., 2. must be completed before the WPO
plan bond can be released:
1) Extended detention basin (current sediment basin serving TNC); convert to SWM. Please see
Notes, below (item 3), for additional background information, or guidance.
2) As -built to confirm existing sediment pond is converted to extended detention basin, per
WP0201300064 design details for'Permanent stormwater structure'.
3) Notes.
a. While sediment basin (SB) is utilized by adjacent property (Three Notch'd Center /TNC)
under approved WP0201300064, this SB requires conversion in the future to receive and
detain runoff from Charlottesville Self Storage at Crozet (CSS), Drainage Shed B.
WP0201500020 review memos (4/9/15; 4/22/15) and approved plan indicate prior -
approved SWM is unaffected by WP0201500020; that is, approved SWM facilities
shown on WP02005-00012, corresponding with SDP2004-00106, Charlottesville Self
Storage at Crozet, include both surface detention and bioretention facilities located on
CSS parcel, TMP 56A3-7.
b. WP0201500085 replaces bioretention with underground detention to provide SW
quantity control for Drainage Shed A, only. Stormwater quality is met with purchase of
0.59 lb. nutrient credits, purchased 3/22/16, to offset loss of phosphorus reduction
provided by bioretention.
c. Neither WP0201500020 nor WP0201500085 eliminate need for SWM detention shown
on WP0200500012, south of storage building C, that also serves a SWM detention
purpose for Three Notch'd Center (TNC /WP0201300064, WP0201700033).
Conversion, when and by whom, is an important topic for another time, but it is apparent
to Albemarle after extensive review that SWM Facility Maintenance Agreement with
Princess Anne LLC (CSS owner, 6/15/2005; deed bk.-pg. 3000-392/395) establishes
maintenance responsibility for CSS to construct and maintain "a combination surface
facility [that] will provide both water quality control and extended detention." SDP2004-
00106, C-11 explains: "Drainage Shed B is comprised of 7.09 Acres, of which 3.66 acres
are onsite [CSS], and 3.43 Acres are offsite [TNC]."
d. Surface SWM detention facility is relied upon by both CSS and TNC.
Engineering Review Comments
Page 2 of 6
e. VAR10G818 may not be terminated until the surface facility (sediment basin) is converted
to extended detention (SWM), consistent with design on C-11A, SDP2004-00106 (i.e.,
WPO2005-00012); also shown on sheet 23, WPO201300064, the last sheet of a 7-sheet
WPO plan.
f. Design details on WPO201300064 should be relied upon since elevations for certain
structural features vary slightly from elevations depicted on SDP2004-00106, and
WPO201300064 is more recent than WPO2005-00012 /SDP2004-00106.
g. Also, see next pp. for supportive graphic /text information.
Please contact me if you have any questions. Thank you.
Sincerely,
John Anderson, PE
(434) 296-5832 ext 3069
Engineering Review Comments
Page 3 of 6
TNC, WM201300064
sheet 20; 41h sheet of WPO plan
FA
ER05ION eInrrs
/
rac
6
/ Foet�AWTf
O
V
sraerbvarErzoFn
N11
ewe A2554 'issM
1
lTP 56A-(3)-1
5�OR46E,
,fFer,
20.
CSS, SDP2004-00106, sheet C-11A ( print plan Not scanned)
P PXX AXMXTT O�nDM n..
654
652
650
646
646
644
642
640
6JB
636
634
632
630
628
Engineering Review Comments
Page 4 of 6
CSS, WP0201500020 (sheet 4: graphic /text images, below):
Label is confusing and may be misleading. File documents indicate SWM is not an existing SWM facility, but
a sediment basin and that it is associated with both CSS and TNC. Also, runoff from CSS paved /impervious
areas is collected at grates and conveyed via pipe to the SWM Ex. detention facility to meet CSS state
stormwater quantity requirements.
i6nu -
I I
I I
1 I
I�
1
EXISTING STORAGE
BUILDING C
1
1
I
I
I
1
1
1
f
STORMWATER
MANAGEMENT
FACILITY
NO PART OF
STORMWATER MANAGEMENT
PUN AND E&S RAN
ASSOCIATED WITH THREE
NOTCH'D CENTER 9TE PUN
s - _..a WPO
2m7
-
.. 4—e-�r/r
1GE
/
)EXISTING ST GE
L , BUILDING A
DRAINAGE:HED:8�1 COISED OF 7.09 ACRES,OF WHICH3.66 ACRES ARE ONSrrE, AND 3.43 ACRES ARE OFFSRE. THE
EXISTING S INSHED B CONSIST OFAN EXISTING PARKING LOT AND OPEN SPACE. THE OIN E AREA WILLBE
REDEVELONEW SELF STORAGE BUILDINGS,ALONG WITH TRAVELWAYSAND PARKINGAREAS. APPROXIATELY0.40IONAL IMPERVIOUS SURFACE WILL BE GENERATED IN SHED B. SURFACE RUNOFF IN SHEDS WILL BE DIRECTED
TO A BISECTING NATURAL DRAINAGE WAY THAT COLLECTS AND CONVEYS SURFACE RUNOFF SOUTHEAST AND EVENTUALLY
OFFSTTE. A COMBINATION SURFACE FACILITY WILL PROVIDE BOTH WATER QUALITY CONTROL AND EXTENDED DETENTION.
STORAGE FOR WATER QUANTITY WILL BE PROVIDED TO ATTENUATE THE 2-YEAR AND 10-YEAR POST -DEVELOPMENT EVENTS.
UTILIZING THE MODIFIED DIRECT METHOD, THE ALLOWABLE RELEASE RATE FOR THE POST -DEVELOPED 2-YEAR STORM IS 21.8
CFS, AND 28.5 CFS FOR THE 10-YEAR STORM. ROUTED RELEASE RATES WERE 8.33 CFS FOR THE 2-YEAR STORM AND 14.19 CFS
FOR THE 10-YEAR STORM. EXTENDED DETENTION VOLUME WILL BE PROVIDED FOR TWICE THE WATER QUALITY VOLUME, AS
DETERMINED BY CAPTURING THE FIRST 34 INCH OF POST -DEVELOPED IMPERVIOUS SURFACE IN DRAINAGE SHED B. THE FACILITY
IS DESIGNED WITH A MULTI -STAGE OUTFALL STRUCTURE CONTAINING A 3' NOTCHED WEIR TO CONTROL THE 2-YEAR STORM
EVENT. THE FACILITY OUTFALL WILL BE PROVIDED BY DISSIPATING ENERGY AND RENDERING THE OUTFALL VELOCITY
NON -EROSIVE PRIOR TO ENTERING THE NATURAL DRAINAGE WAY.
WP0201500085 (CSS, biofilter removed; underground detention replaces bioretention; surface SWM from
WP0200500012 remains (2'd sheet of 5-sheet plan; plan approved 6/13/16 by J. Anderson/Alb.):
Engineering Review Comments
Page 5 of 6
Ex. detention basin (Stormwater Management Facility, image below) is also associated with C. Self Storage
WP02005-00012, WPO201500020, WP0201500085, and required for SW quantity control, drainage shed B.
3VNW-DI5ITGRB B fFER
IT IT�1'I -
r /
w'rRBAMBI
r/
1
TORMWATE
.� AGEMENT
FACILITY 6 Sa \ \ I
I A6 \ \ 1
i NNG STORAGE EXISTING S RACE �� l
BUILDING D BUILDING C TING POND PA I \
\ STD TER MANAGEM T
•\ ANDES PO
/,Yi
o
EXISTIN STORAGE
EI7TING ASPHALT _ - �•/ ING B
RWEWArS(
WP0201300064, Three Notch'd Center, approved 4/15/15, sheet C23 (71 sheet of plan)
Permanent Storm Water Structure — rely on WPO201300064 design elevations
PERMANENT STORM WATER STRUCTURE
654
652
650
648
646
644
642
640
638
636
634
632
630
628
626
624
SCALE 4.1
Engineering Review Comments
Page 6 of 6
VSMP plan review Memo (J. Anderson /WPO201500020. Approved 22 Apr 2015)
VSMP Permit plan review Approved
Project:
Charlottesville Self Storage at Crozet, VSMP
Plan preparer:
Scott Collins, Collins Engineering [200 Garrett St., Suite K, Charlottesville, VA
22902, scoff tAcollins-eneineerine.coml
Owner or rep.:
H.M. Walker, Jr./Albemarle Storage, LLC, P. O. Box 332, Charlottesville, VA 22902
Jo Higgins, Project Development LLC, 2564 Mt. Torrey Road, Lyndhurst, VA 22952
T: 434.326-0334 1 musxit(a.aol.com
Plan received date:
6 Apr 2015
(Rev. 1)
16 Apr 2015 (.PDFs)
(Rev-Irev)
22 Apr 2015 (Final)
Date of comments:
9 Apr 2015
(Rev. 1)
21 Apr 2015 (e-review comments/email)
(Rev-lrev)
22 Apr 2015-AAWroved
Reviewer:
John Anderson
Notg/Current bond amounts: $4,500 remains on WPO/ESC (BND200500021 WP-SE); $62,000 (original) remains on
WPO/SWM bond (BND200500022WP-SW).
A. Stormwater Pollution Prevention Plan (SWPPP) —All comments addressed —CV/prior comments.
The SWPPP content requirements can be found in County Code section 17-405. A SWPPP must contain (1)
a PPP, (2) an ESCP, (3) a SWMP, and (4) any TMDL measures necessary.
B. VSMP: SWPPP: Stormwater Management Plan (WPO201500020)
VSMP Regulation 9VAC25-870-108 requires the VSMP authority to approve or disapprove a SWMP. The SWM
Plan for post -developed site conditions associated with ESC Plan submitted with this VSMP Application was
approved as WP02005-00012/SDP2004-00106. Prior approval and design are unaltered and unaffected under
this VSMP Application, which proposes construction of remaining self -storage units, and converts sediment trap
to SWM bioretention facility. Reference ACCD Files/SWPPP for prior -approved SWMP, or plan details.