Loading...
HomeMy WebLinkAboutSDP200500111 Calculations Minor Amendment 2006-01-03 1350 Stony Point Road Rivanna Engineering 434.984.1599 Charlottesville, VA 22911 & Surveying, PLC (F) 434.984.8863 Memorandum To: Allan Sd uck From: Tim Miller CC: Tony Date: January 2, 2006 Re: Minor Site Plan Amendment for Carriage Gate Apartments Dear Alan; This is in response to your comment on the Carriage Gate Apartments Minor Site Plan Amendment. We have added four concrete channels along the parking area as we discussed. Attached is a drainage area map of this area. The run-off calculations are as follows: RECEIVED DA-1: Area=0.05 Acres, C=0.90, 1=4.0 inches/hr. Q=0.18*0.90*4.0= 0.18 cfs. AN 03 2006 DA-2: Area =0.07 Acres, C=0.90, 1=4.0 inches/hr. COMMUNITY DtVtLU,MENT Q=0.07*0.90*4.0= 0.25 cfs. As the run-off exits each channel it will spread out across the pavement. Spread width downstream from each channel will average approximately 10-feet (20-feet total since there are two channels per drainage area), and have a velocity of at least 2 fps. Under these conditions the depth of flow for 0.18 cfs will be 0.0045 feet, and depth of flow for 0.25 cfs will be 0.0063-feet. These depths will not cause hazardous conditions as it flows across the travel way. Please contact me if you need any additional information. • .— _/ �„ _, I / oMH-3588 , 584 582I I .9:t AI n DI WATER MAIN 8" 45.DIP 1 Bend = T-2 a: —2 (.;\ E. �fl.� `n 1 . a, l�s�o _�t ��8J"T' A '�`1� •� T-1 N¢ ` 1 0 ICO ,�Relocated �� I �QPO� es �' from near 1 p. STR-3 I I % + �iBPD � , 0 r Water,r 1 0 / i IW 0 / eft ` r: ILI j L / Ai 2 1 i/ /" ii Max �. // Fixti 1 A.0 /ems. ssJ / tN� (lr 1 T-1 / / #� / 1 J y i ;, TSB , CO , " etia.i1 !r Na / / iL N / T-r • ---mill • imi:El.i.,*2 /---01111110- 441` " T- 8 'BO— " / / ffiV' 1 * I * + it / - -3 Oi //-22•- OS FHWA Urban Drainage Design Program, HY-22 Drainage of Highway Pavements Inlets on Grade Date: 01/02/2006 Project No. : 1139 Project Name. :Carriage Gate Computed by :Rivanna Engineering 'ect Description epth of Water on Speed Bump to rainage nl et ST- Inlets on Grade: Gutter Flow Parameters Roadway and Discharge Data Cross Slope Uniform S Longitudinal Slope (ft/ft) 0 . 0450 -v13 Sx Pavement Cross Slope (ft/ft) 0. 0200 - - c9 B Sw Gutter Cross Slope (ft/ft) 0 . 0200 '7_ n Manning' s Coefficient 0. 016 W Gutter Width (ft) 1. 00 a Gutter Depression (inch) 0 . 00 Q Discharge (cfs) 1. 770 T Width of Spread (ft) 6. 74 Gutter Flow Eo Gutter Flow Ratio 0 . 349 d Depth of Flow (ft) 0. 13 = ‘,ca z,,\ ✓ Average Velocity (ft/sec) 3. 90 VA = o.(a-AMS L = 4.0 1 hr • FHWA Urban Drainage Design Program, HY-22 Drainage of Highway Pavements Inlets on Grade Date: 01/02/2006 Project No. : 1139 Project Name. :Carriage Gate Computed by :Rivanna Engineering Project Description Depth of Water on Speed Bump to Drainage Inlet ST-2A Inlets on Grade: Gutter Flow Parameters Roadway and Discharge Data Cross Slope Uniform S Longitudinal Slope (ft/ft) 0. 1000 Sx Pavement Cross Slope (ft/ft) 0. 0200 Sw Gutter Cross Slope (ft/ft) 0. 0200 n Manning' s Coefficient 0. 016 W Gutter Width (ft) 1. 00 a Gutter Depression (inch) 0 . 00 Q Discharge (cfs) 0. 190 T Width of Spread (ft) 2 . 52 Gutter Flow Eo Gutter Flow Ratio 0 . 741 d Depth of Flow (ft) 0 . 05 = ✓ Average Velocity (ft/sec) 3 . 00 = D.O(o G<<eS C = 0,11 = LF,0.‘4n v\r -"* p '/ ) 1 P - ---, -\\ \, 1I ..- : I, • . -----.---\\ \ ‘ -,.... . , 4.. -1___ i __, ,, \ \ \ \ „ , , ., it. ‘ \�\ N 1 - \ \\ \ \ ` ,...... , _ - - - _ _ 1 ________ - ___, •, \� 1 „ \ \ , \ , , \ ,\ , ..... 11 11 \ \` \ '\• y 11 \ 11 1 \ --....‘ "------! / • ` 1 1 , ` \ 2-f/A T-CAR -. _ -$-CAR 2-CAuC r.� MAW II ACF aARC•1 GAR• Lll •• I �g5 11 z �`� • \ \ \\ , rai , It' � 1 J I • 582 1 ( 8 • I 9q5 ii If \ I \ 1 \ II t \ 1---- , ;I \\\\ ` 580 . . I All I. . I ., Mill; ego , \ ilk \ m 1 a rr„�JJ 09S .... t:,i.„ ,,,, .. I ili,,,i il i I,, iRgRgy 1� J „„i i i., o c \\\ \ I ` \ • 1 g hi I ; , N. _____-\\ ,..,,-, \ .. ......._ •„... 1, , 1 ,, ,, Pim I - 5 Lb, . . . ,....._. -_,..„ . I tam o ii1 • \ I���il oks \ !1 e' ir �\_ i. , , 1\1. 1..1,1 a�1~e c , wig I -�iw 1 ) \ 1 — bCbSa /, I v I ( i I. . i 1 J4dLt 1 1 -itr.,il— • :i, , ,- / o ur i-rr72. :i.l( •ii ,lik\ fr ::< ,...i.,.2. -.sill\ [55OT\_ ® 4.t iizz,%t •• •I 1 r�� ,- -i ` \ � it li --,-_ N. i /. \'.\'-,111111111111111\„, '''....."---.-, /----, . ii _•.=emme. Alt 414 . \ \` . off' ,: /, „: , ,..141114 lg. , ---.„.... -......-t; . If 1 \ ../ P. -,� VV// �. ti �J f j I ! // • ,..-,,L,Ntt:.,,. 2,.:, \ Y,,'..., ;Y b .,.: 1 1--\ \ / , I , ,_ A ,} _ b ; C' 1 /I, , I' r, /z ....... .. ,/I ,..77 y y 7 ,. -mom `� Cyr Project Tile, Droving 11t1e: c CD MINOR SITE PLAN AMENDMENT FOR y,+j° "�"'0y� RIVANNA ENGINEERING & z CARRIAGE GATE APARTMENTS CD DRAINAGE AREA MAP N: I_ 0 A SURVEYING, PLC. 0 4a �. o Rio District, Albemarle County, Virginia Drawing Scale: As Shown Drown By roe fie Nome:45-91-YA.dwg o %fR ". r'k 1350 Stony Point Rd PHONY:(494)984-1599 yIN Dote:. 01.03.06 Checked By 1RU Project No.: 1139 r� Charlottesville.VA 22911 FAX: (434)984-8863 1350 Stony Point Road Rivanna Engineering 434,984.1599 Charlottesville, VA 22911 & Surveying, PLC (F) 434.984.8863 Memorandum Ta Allan Sthudc From: Tim Miller CC: Tony Date: November 22, 2005 Re: Minor Site Plan Amendment For Carriage Gate Apartments Dear Alan; This is in response to your comments on the Carriage Gate Apartments Minor Site Plan Amendment. You have indicated that you would be amenable to reviewing run-off calculations for the revised parking area at the rear of the site. Attached is a drainage area map of this area. We have added a channel at each end of the parking area. The run-off calculations are as follows: DA-1: Area=0.05 Acres, C=0.90, 1=4.0 inches/hr. 0=0.18*0.90*4.0= 0.18 cfs. DA-2: Area =0.07 Acres, C=0.90, 1=4,0 inches/hr. Q=0.07*0.90*4.0= 0.25 cfs, As the run-off exists the channels it will spread out across the pavement, Spread width will average approximately 10-feet, and have a velocity of at least 2 fps. Under these conditions the depth of flow for 0.25 cfs will be 0.012 feet, and depth of flow for 0.18 cfs will be 0.009-feet. These depths will not cause hazardous conditions as it flows across the travelway. Please contact me if you need any additional information. N-3 584 i 8" PVC Smith( 5152 58810 AZ ? vor _4 i, - raf t:"."�J1:--- I - �r-r — 3 r.a 111/ 4,9/ 1 % A •I . ar MAINI i _8" 45'DT Bend �w ( 2 amp ; 11 A' i • �w al x[5 7 3 i ~, tf `r$ *Iv9 N��a ``3 f-I o �y� T-I S.�_ 1/4::: r ji tom' �, ® A 1 5 RelocaEed I gm, / pA�' a STR-3 t3Po J 1 1/2" a I ' / 'Abler' 0 o Vv1-/ Q co ; 1 r / j I ^ Ln a ,/` ; ; • la i l ' I ( s f � 0 , ' `h� 2 1 f • i /' / Max •� a / / Fib r l ‘-r4 I ,...- Ni rliligglIMMO 1 0 D i I+ / i� rr 'r e / -FP Ma , T- f i 41) I. 1a- .01 f (' ' - Alm_ �� �.��1i ^%�• '_ ors ii 1 //--22- OS