Loading...
HomeMy WebLinkAboutSDP201300029 Application 2013-05-07 °4s Albemarle Cou,1/ Community Development Department 401 Nleftntire Road Charlottesville,VA 22902-4596 11'� o-� 't Planning Application Voice:(434)296-5832 Fax:(434)972-4126 [PARCEL/ OWNER INFORMATION TMP 056A3-00-00-00900 Owner(s): Application # SDP201300029 NOTCH'D LLC PROPERTY INFORMATION Legal Description ACREAGE Magisterial Dist. White Hall Land Use Primary Residential --Single-family (incl. modular homes) Current AFD Not in A/F District Current Zoning Primary Planned Development Shopping Center APPLICATION INFORMATION Street Address 5368 THREE NOTCH'D RD CROZET, 22932 Entered By Todd Shifflett Application Type Site Development Plans 05/07/2013 Project Three Notch'd Center- Minor Received Date 05/06/13 Received Date Final Submittal Date 05/06/13 Total Fees 500 Closing File Date Submittal Date Final Total Paid 500 Revision Number Comments Legal Ad SUB APPLICATION(s) Type I Sub Applicati I Comment Minor Amendment 1.05/06/13 'APPLICANT/ CONTACT INFORMATION iNOTCH'DLLG 90 STOCICf,+DN.�ss ( CityState Zip � Phone � PhoneCell onenAPP ne Name a9. ._...._...._,....Addy RIDGE PL. GREENWOOD VA 22943 ' ContactType • Primary Contact JO HIGGINS - PROJECT DEVELOPMENT L 2564 MT.TORREY ROAD LYNDHURST,VA 22948 4343260334 Signature of Contractor or Authorized Agent Date ei Tlication for Major or Minor Site Plan Amendments Existing Site Plan Name&Number: Three Notch'd Center;SDP-2008-00179 Tax map and parcel(s): 56A(3)-9 Zoning: PDSC- Planned Development Contact Person(Who should we call/write concerning this project?): JO Higgins- Project Development LLC Address 2564 Mt.Torrey Road City Lyndhurst State VA Zip 22952 DaytimePhone( 43 326-0334 Fax#( ) E-mail musxit @aol .com Owner of Record: Notch'd LLC Address 90 Stockton Ridge Place City Greenwood State VA Zip 22948 Daytime Phone(42✓ 9M t 4101,A Fax#( ) E-mail Applicant(Who is the Contact person representing?): Notch'd LLC Address 4/41446. City State Zip Daytime Phone( ) Fax#( ) E-mail FEES ❑ Major Amendment ® Minor Amendment(alterations to parking,circulation,building =$1500 size,location)=$500 16 folded copies of plan are required 8 folded copies of plan are required Notices required by Section 32.4.2.1 (f) Preparing and mailing or delivering up to fifty(50)notices=$200.00 plus the actual cost of first class postage. Preparing and mailing or delivering,per notice more than fifty(50)_$1.00 plus the actual cost of first class postage. GROUNDWATER ASSESSMENT (Required for all non-residential site plans not serviced by public water) Was a Groundwater Assessment conducted for the existing site plan? ❑ YES CO NO (Not Applicable) If NO and the new plans show a use using less than 2,000 gallons/day(average) ❑ Tier 3 Groundwater Review=$510 If NO and the new plans show a use using greater than 2,000 gallons/day(average) ❑ Tier 4 Groundwater Review=$1,100 If YES and the use goes from using less than to more than 2,000 gallons/day(average) ❑ Tier 4 minus Tier 3=$590 If YES and the use does not change from using less than to more than 2,000 gallons/day(average) ❑ No fee FOR OFFICE USE ONLY SDP# � {{ �/� D ((j ' y ?kk* h('a � p 1 By: y�/► �/�7 Fee Amount$) ,1 J ) Date Paid- B who. Recei t#F� Ck#C tbS I B I mil./ County of Albemarle Department of Community Development 401 McIntire Road Charlottesville,VA 22902 Voice:(434)296-5832 Fax:(434)972-4126 1/1/2013 Page 1 of2 Comments/Attachments: Owner/Applicant Must Read and Sign ❑ Manor Amendment This major amendment as submitted contains all of the information required by Section 32.5(Initial Site Plan)and Section 32.6(Final Site Plan)of the Albemarle County Zoning Ordinance. I understand that plans which lack information required by said sections shall be deemed incomplete and shall be denied by the agent within ten(10)days of submittal as provided in Section 32.4.2.1 or Section 32.4.3.1 as the case may be. ® Minor Amendment This minor amendment as submitted contains all of the information required by Section 32.5(Initial Site Plan) and Section 32.6(Final Site Plan)of the Albemarle County Zoning Ordinance. a I am consenting to all correspondence from Albemarle County be in any of the following forms in writing;by first class mail,by personal delivery,by fax or,by email. ❑ I am not consenting to all correspondence from Albemarle County in the form of fax or email. Signature of• - ;- ..' _- Agent Date 43,4- 3210-o3 Print Name Daytime phone number of Signatory 1/1/2013 Page 2 of 2 NP Engineering May 6, 2013 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22901 RE: Three Notch'd Center (SDP-2008-00179) Minor Site Plan Amendment Application To whom it may concern: Listed below is the required list of proposed changes to the Three Notch'd Center approved final site plan (SDP2OO8-179) for the minor site plan amendment application. 1. Phasing of the development with an initial phase which includes: a. Addition of an Auto Laundry (car wash) building and associated sitework; b. Closing of existing entrances along Rte 240; c. Addition of a CG-i 1 entrance to support the initial phase; 2. Phasing of development with a final phase. Revisions include: a. Adjusted building floorplan and square footage; b. Adjusted parking,sidewalk and grading to accommodate the initial phase; 3. Revised sheets: a. Sheet C-1: Cover Sheet (revised); b. Sheet C-4.1: Initial Phase-Ex Conditions & Demo Plan (added); c. Sheet C-4.2: Initial Phase-Site Layout Plan (added); d. Sheet C-4.3: Initial Phase-Landscape Plan (added); e. Sheet C-4.4: Initial Phase-Photometric Plan (added); f. Sheet C-5: Final Phase-Ex Conditions & Demo Plan (revised); g. Sheet C-6: Final Phase-Site Layout Plan (revised); h. Sheet C-7: Final Phase-Site Grading & Utility Plan (revised); i. Sheet C-8: Final Phase-Dimension Plan (revised); j. Sheet C-9: Final Phase-Storm Profiles (phase line added, revised); k. Sheet C-11: Final Phase-Landscape/Site Lighting Plan (revised); I. Sheet C-12: Final Phase-Photometric Plan (revised); Should you have questions regarding the minor site plan amendment, please call me at (434) 531-7387. Sincer Nat Perkins, P.E. 680 IVY FARM DRIVE • CHARLOTTESVILLE.VIRGINIA 22901 • PHONE: (434) 531-7387 • '7`"v(, —4 IATO L4 i4 b MINOR AMENDMENT CHECKLIST S1P'-2do8--Done\ Final Site Plans approved prior to 5-1-87 that are proposed to be changed with a minor amendment must include the applicable site plan content requirements of Section 32.5 and 32.6. (See checklist online or obtain a paper copy from the main office). If content required by sections 32.5 and 32.6 is requested to not to be provided then a site plan waiver must be processed. ✓1. Appropriate application filled out and fee paid. v'2. Plan is prepared and sealed, signed and dated by an architect,professional engineer, land surveyor, or certified landscape architect, each of whom shall be licensed to practice in the Commonwealth of Virginia. /3. Final Site Plan number that the amendment applies. 4. List of the proposed changes. ( c q 1,514G}4C,p LSE-2J ✓5. Graphic delineation of the proposed changes (bubble, other symbols). q(0/1" Final Si�,,Development Plan , Yom,r. Checklist 4 ®,, Project Name: Three Notch'd Center(Minor Site Plan Amendment) Firm: NP Engineering This checklist must be completed,signed and submitted with the application. The information contained in this checklist reflects the contents of the Section 32 of Chapter 18 of the Code of the County of Albemarle also known as the Site Plan Ordinance as of January 1,2013. The applicant is responsible for insuring that no revisions to the Ordinance have occurred since preparation of this document. This final site lan�has: ►-t.,' ve. 5i iT P�aJ .4�9 m&J' ❑ an•site-plan that was approved for the development and it remains valid; SDP-20 b'p - (?(7 1771 ❑ satisfied all of the requirements of section 32.6 below;and ❑ satisfied all of the conditions delineated in the letter provided under section 32.4.2.5(c)required to be satisfied prior to submitting the final site plan. Lid" Authori preparer. The plan,and any amendments to a plan,is prepared and sealed,signed and dated by one of the following ❑ An architect licensed to practice in the Commonwealth of Virginia. A professional engineer licensed to practice in the Commonwealth of Virginia. ❑ A land surveyor licensed to practice in the Commonwealth of Virginia. �/ ❑ A certified landscape architect licensed to practice in the Commonwealth of Virginia. Ga Num_becopies when first submitted. ld Eight(8)clearly legible copies in blue or black ink of the plan if the applicant has a preliminary site plan that was approved prior to January 1,2013,in the scale and size required below,or ❑ Two(2)clearly legible copies in blue or black ink of the plan if the applicant has an approved initial plan,in the scale and size required below,and �� ❑ One(1)reduced copy of the plan no larger than eleven(11)by seventeen(17)inches in size. l Scale a94.size. a The plan is prepared to the scale of one(1)inch equals twenty(20)feet or larger,or to another scale approved by the agent ip a particular case. Other scale approved -one(1)inch equals 30 ( )feet,by kr/No sheet exceeds forty-two(42)inches by thirty-six(36)inches in size. Id The plan IS prepared on one(1)sheet.OR ❑/The plan IS prepared on more than one(1)sheet and match lines clearly indicate where the several sheets join. lld The top of each sheet is approximately Gds North or ❑ East ❑ Dimensions. The plan is dimensioned to at least the following standards for accuracy: ld" Boundary,setback and zoning lines:Within one one-hundredth(0.01)of a foot. ��Existing contours: Within one-half(1/2)of the contour interval required in section 32.6.2(c). ld Proposed contours: Within one(1)foot horizontally and vertically. lta Spot elevations:Within one-tenth(0.10)of a foot. ltd Existing critical structures including utilities and other topographic features:Within two(2) feet, provided that for critical structures,which include,but are not limited to,gas lines,other utilities,pipes, conduits,walls and buildings to be preserved,within one-tenth(0.10)of a foot. L:1 Proposed structures,roads,parking lots and other improvements:Within one one-hundredth(0.01)of a foot. 4/10/2013 Page 1 of 4 Alber---le County-Final Site Plan Checklist Site Plan Ordinance Section 32.6- Coro.,,,.s of final site plan .,.s,,,. In addition to containing all of the information required to be on an initial site plan, as provided in section 32.5, a final site plan shall contain the following: (Demonstrate compliance with chapter. Specific written schedules or notes as necessary to demonstrate that the requirements of this chapter are satisfied. 1Proposed grading. ❑ Proposed grading(up to twenty [20]percent slope,maximum two [2] foot contours;over twenty [20] / percent slope,maximum five [5] foot contours). H Water and sewer facilities. etailed plans for proposed water and sewer facilities,including all pipe sizes,types and grades; proposed connections to existing or proposed central water supplies and central sewage systems; [�' location and dimensions of proposed easements and whether they are to be publicly or privately maintained; ❑ _profiles and cross sections of all water and sewer lines including clearance where lines cross; a' all water main locations and sizes; valves and fire hydrant locations; Il sewer appurtenances by type and number; ❑ the station on the plan to conform to the station shown on the profile and indicate the top and invert elevation of each structure. ❑✓braina and grading plans. 6d Detailed construction drainage and grading plans: ❑ Profiles of all ditches and channels whether proposed or existing, showing existing and proposed grades, and invert of ditches,cross pipes or utilities;typical channel cross sections for new construction; and actual cross sections for existing channels intended to remain; Ciljt rofiles of all storm sewer systems showing existing and proposed grades; L Plan view of all drainage systems with all structures,pipes and channels numbered or lettered on the plan and profile views. Show sufficient dimensions and bench marks to flow field stake out of all proposed work from the boundary lines; A drainage summary table for culverts,storm sewer and channels as described in the following example: Structure Description Length Invert Invert Slope Remarks Number In Out 1 42"RCP 50' 24.50 424.00 100.00% Provide Class III 2, EW 2 DI-3B L=8 26.00 432.00 - IS-1 Top 3 PG-2A 400' 420.00 400.00 5.00% D=12" 4 Grade 200' 420.00 415.00 2.50% D=18" / Swale Lid' A legend showing all symbols and abbreviations used on the plan; General notes,typical sections,and details of all items not covered by Virginia Department of Transportation standard drawings;and 14A ❑ Flood plain limits for the one hundred(100)year storm for all watercourses with an upstream drainage area of fifty(50)acres or more provided that the county engineer may waive this requirement for drainage areas of less than one hundred(100)acres upon determining that the information is unnecessary for review of the proposed development. Revised 4/10/2013 Page 2 of 4 Albe'- .le County-Final Site Plan Checklist ❑ Street sections. J/P ❑ Typical street sections together with specific street sections where street cut or fill is five(5)feet or greater; ❑ centerline curve data; ❑ radius of curb returns or edge of pavement; ❑ location,type and size of proposed ingress to and egress from the site together with culvert size; ❑ symmetrical transition of pavement at intersection with existing street; ❑ the edge of street surface or face of curb for full length of proposed street; ❑ when proposed streets intersect with or adjoin existing streets or travelways,both edges of existing pavement or travelway together with curb and gutter indicated for a minimum of one hundred(100) � feet or the length of connection,whichever is the greater distance. and utilities. Ulvi All public facilities,utility and drainage easements outside the right-of-way of public streets, provided at new easements may be generally shown and accurately dedicated by separate plat. All water and sewer facilities to be dedicated to public use and the easements for those facilities and shall be identified by a statement that the facilities are to be dedicated to the Albemarle County Service Authority. hd' Signaatu e panel. by Signature panel for signature by each member of the site review committee. LI arkiinmnd loading areas. rO For all P4rking and loading areas, indicate the size, angle of stalls, t17-- width of aisles and specific number of spaces required and provided,and method of computation. Indicate type of surfacing for all paved or gravel areas. Landsc pe plan. ,VA landscape plan that complies with section 32.7.9 G/Outdoor 'ghting. Outdoor fighting information including a photometric plan with CY location,description,and photograph or diagram of each type of outdoor luminaire. ❑ Recreational facilities.44 ❑ Specifications for recreational facilities. In addition to the items required by the ordinance,Albemarle County Engineer,the Virginia Department of Transportation,the Albemarle County Service Authority,and the Thomas Jefferson Health District require these items on plans submitted for final site plan approval. Plans will not be rejected if these items are not present, but they are required for approval. These items are provided in an effort to communicate all final site plan comments. ❑,/1.Reference the benchmarks used for surveys. (Albemarle County Engineering Policy) ❑ 2. Indicate the available sight distance for entrances and left turn lanes. (Albemarle County Engineering Policy) ❑ 3.Label the maximum height of all retaining walls. (Albemarle County Engineering Policy) Nh ❑ 4.Provide copies of off-site easements,or letters of intent to grant them from off-site property owners. (Albemarle County Engineering Policy) vo J .�w,L ii Qu,J Revised 4/10/2013 Page 3 of 4 Albe- -rle County-Final Site Plan Checklist *w LV 5. Show and label stream buffer limits. (Water Protection Ordinance, WPO) u 6. Indicate the deed book and page reference for all existing utility easements located on the property. (Albemarle County Service Authority) J11A ❑ 7. Tier 3 -Draft or Final Groundwater Management Plan(WPO Section 17-403) 1.1�A ❑ 8. Tier 4—Aquifer testing work plan(WPO Section 17-403) Read and Sign In representing the above referenced firm submitting this plan for final approval,I hereby sate that,to the best of my knowledge,the attached plan contains . information required by this checklist. - 5/6/13 Signalmrevf:OwnerantradPstiehaser,Agent Date W.Perkins (434) 531-7387 Print Name Daytime phone number of Signatory Revised 4/10/2013 Page 4 of 4