HomeMy WebLinkAboutARB202200066 Architectural Drawings 2022-10-18BUILDING B - WEST ELEVATION
x
L7
w
x
L9
z
0
J
m
BUILDING B - NORTH ELEVATION 4
BUILDING B - EAST ELEVATION
1/8" = 1'-0"
x
x
z
z
D
J_
n
2
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
SYM. LEGEND
ODENOTES MATERIAL
ODENOTES WINDOW NUMBER
(SEE SHEET AX.XX FOR
SCHEDULE)
O 1 MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
M9 METAL COPING
O I PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
KEY PLAN
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
O
Ir
I—
Z
CW
G Q
a_ >
O
w I-
Z
W D
o —O
�0 U
Z W
O LL _j
a_
ZOO
LLI
O m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
BUILDING B - SOUTH ELEVATION
1
EXTERIOR
ELEVATIONS -
BUILDING B
A2.01
00
0
ROOF BEARING h
30'-5114" /
THIRD FLOOR h
21 _4
" V
SECOND FLOO__
10'-8" Y
FIRST FLOO
0,_0. TR
BUILDING C - NORTH ELEVATION 4 1/8" = 1'-0'
BUILDING C - WEST ELEVATION 3 BUILDING C - EAST ELEVATION 2
1/8"
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
SYM. LEGEND
ODENOTES MATERIAL
ODENOTES WINDOW NUMBER
(SEE SHEET AX.XX FOR
SCHEDULE)
O 1 MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
M9 METAL COPING
O I PAINT COLORS
P1
EXTRA WHITE - SW7006
P2
GRAY SCREEN - SW7071
P3
ROYCROFT PEWTER - SW2648
x
=
P4
SMOKY BLUE - SW7604
z
z
P5
LIGHT BRONZE - TBD
KEY PLAN
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
O
Ir
I—
Z
CW
G Q
a_ >
O
w I-
Z
W D
o —O
� U
Z W
^O ry
L.L
ZOLLI
O m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
EXTERIOR
ELEVATIONS -
BUILDING C
BUILDING C - SOUTH ELEVATION
1/8" — 1'-0'
A2.02
BUILDING D - WEST ELEVATION 3
1/8" = 1'-0.
(7
w
z
z
0
J_
00
m
BUILDING D - NORTH ELEVATION
2
BUILDING D - EAST ELEVATION 2
1/8" = 1'-0"
ROOF BEAR. B ING h
30'-51/4" V
THIRD FLOOR h
27' - 4"
SECOND FLOOR h
wl
FIRST FLOOR $
D•_Q' �I
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
SYM. LEGEND
ODENOTES MATERIAL
ODENOTES WINDOW NUMBER
(SEE SHEET AX.XX FOR
SCHEDULE)
O 1 MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
M9 METAL COPING
O I PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
KEY PLAN
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
O
tr
Z
CW
G Q
a_ >
O
w I-
Z
W D
o —O
�0 U
Z W
O LL -i
a_
ZOO
LLI
O m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
BUILDING D - SOUTH ELEVATION
1/8" = 1'-01,
1
EXTERIOR
ELEVATIONS -
BUILDING D
A2.03
❑
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
- T �4 4T1-4 __.J=r-r
4
VERTICAL RISE TO HAVE MINIMUM S'-6" HIGH
' -
GUARDRAILS AS PER THE BUILDING CODE.
I
T z
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
jr
_
z�
MATERIALS. THE WALL SECTIONS AND DETAILS
��� � ul���r
=�
�' ��
�Y
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH TRIM. ALL MATERIAL
TO
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
— �-�
` ;
�
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
-
�
=
ROOF BEARING /
30' - 5 BEARING
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
❑
F[E
v
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
�*
THIRD
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
rn —
�FLOOR �
21 _4" r
CORNERS FULL HEIGHT OF WALL (TYP.)
I
w
d
7. PROVIDE CONT. BUILDING WRAP OVER
"COMMERCIAL TO
BE BASIS OF D SIGN SP CIFICAT O S.
i
b
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
=
SECOND FLooR
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
a-S
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
TOWNHOME A- NORTH
ELEVATION
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
4
118" = 1'- r
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
�
❑
SYM. LEGEND
ROOF BEARIN�G T
ROOF BEARING
�T
30'-57/4"
I
30'-51/4'
ODENOTES MATERIAL
m
a,
DENOTES WINDOW NUMBER
It
(SEE SHEET AX.XX FOR
O
THIRD FLOOD
—21'-4„ V
THIRD FLOOR
V
SCHEDULE)
21• 4••
ED FPT �
o
■
d)
o
O
❑
MATERIALS
�o
II
M
SECOND FLOOR J,
ECOND FLOOR=;;==I=
=
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
co
ao
0
o
M3 FIBER CEMENT BOARD AND BATTEN
FIRSTFLOOR
— FIRSTFLOOR
M4 METAL STANDING SEAM ROOF
0•_0'
ry_p T
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
TOWNHOME A
-WEST ELEVATION
❑
TOWNHOME A - EAST
ELEVATION
M9 METAL COPING
❑1/8'
= 1'-0"
118
1
�
r
1
PAINT COLORS
P1 EXTRA WHITE - SW7006
ROOF BEARING
❑
❑ O
I
❑
❑
�
IIJ ❑
�
O L1_I_l
30' - 5 114"
P2 GRAY SCREEN - SW7071
I
1
I
m
P3 ROYCROFT PEWTER - SW2648
THIRD FLOOR h
21'
P4 SMOKY BLUE - SW7604
mm
e
H_
ud
m y
m
P5 LIGHT BRONZE - TBD
I
11
ou
o
SECOND FL0008
ILLn❑
KEY PLAN
o000
o000 o000
o00o I,
o000 `°
,n
II
,
,
o
,I
FIRST FLOOR
0' - 0"
TOWNHOME A - SOUTH
ELEVATION
1/8" = V-0'
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
D
V
a
Ong
ff
2
Q
>
O
w��
W
Z
D
o
—O
�
U
Z_
a_
'�^,LJ
ZOLLJ
O
m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
EXTERIOR
ELEVATIONS -
TOWNHOME A
W11:511
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
s
L
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
T
VERTICAL RISE TO HAVE MINIMUM S'-6" HIGH
LT -
�r
GUARDRAILS AS PER THE BUILDING CODE.
—��
-
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
���`
r
r
r r ` L "
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
T
•� T, -
�, },-
-�
� � � -. ,-�-
� -r
_
PANEL /SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
RooFBEARINc �,
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
Elm_
3B'-5�
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
-
- -
I
TRANSITIONS BETWEEN WALL FINISHES.
-
-
0
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
THIRD FLOOR h
— 22
F
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
�I
❑
❑
=
o z
LO
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
"COMMERCIAL
SHEATHING - TYVEK WRAP" TO
1
NE{
1
1
o
r1
m
BE BASIS OF DESIGN SPECIFICATIONS.
SECOND FLOOR
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
0171
tl
� �
_
°D
9. TERM FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
LDFLANGED
EXHAUST LOUVER AT DUCT
,'
PENETRATIONS AT WALLS (TYP).
--`
-
- � - - =
FIRST FLOOR
° °
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
TOWNHOME B-
NORTH
E L E VAT I O N
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
1/8" = 1'-O"'
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
SYM. LEGEND
ROOF BEARING I�
30' 551w
_
ROOF BEARING
30'-51/
FFF
a
O DENOTES MATERIAL
0
0
DENOTES WINDOW NUMBER
THIRD FLOOR h
— 2r_a^
—
THIRD FLOOR
- FL
(SEE SHEET AX.XX FOR
O
SCHEDULE)
❑
B e
v
o to
.
� �
co V
o0
�O
MATERIALS
o
m
co
SECOND FLOOR h
19
_
LooR
SECOND F_�
70'-8"
M1 STONE VENEER, RUNNING BOND
IF-M2
FIBER CEMENT LAP SIDING
e0
e0
0
o
M3 FIBER CEMENT BOARD AND BATTEN
FIRST FLooR
FIRsr FLooR
M4 METAL STANDING SEAM ROOF
37' - 11 13/16"
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
TOWNHOME B -
WEST ELEVATION
TOWNHOME
B - EAST
ELEVATION
OMETAL COPING
,
T
„
TT
PAINT COLORS
-
P1 EXTRA WHITE - SW7006
GRAY SCREEN - SW7071
ROOF BEARING h
_ 30 -51/4' '
I HH
THIRD_FLOOR
21
r
P3 ROYCROFT PEWTER - SW2648
❑
❑
❑
❑
.
e° �*
=
o �
z
P4 SMOKY BLUE - SW7604
o �n
a�i
P5 LIGHT BRONZE - TBD
-roi
m
-
--
SECOND FLOOR h
o000
o00
o000
o00o i o000
❑KEY
PLAN
0
L 77.s;
�
71:
17=7
PT
FIRST FLOOR
0'-0"
TOWNHOME B - SOUTH
ELEVATION
1/8" = 1'-0'
220 E. Peterson Dx.
Chazlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
G
Q
�
O
w
W
Z
D
o
—O
�
U
Z
W
O
�
a_
L.f�
/r
ZOLLI
O
m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, INS, RES
CHECKED BY: JL
EXTERIOR
ELEVATIONS -
TOWNHOME B
A2.05
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
- `
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
AN\
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
I''
�
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
�
TRANSITIONS BETWEEN WALL FINISHES.
LOUNGE ROOM DORMER ROOF
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
LUBHOUSE ROOF BEARING
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
UBHOUSE LEASING ROOF
_ BEARING
I
CORNERS FULL HEIGHT OF WALL (TYP.)
��ir-B^
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
o
I
,
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
�
AT ALL WALL SURFACES PRIOR TO EXTERIOR
II
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
_
_ -- -
FIRsrFLOOR
h
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
CLUBHOUSE -
NORTH
ELEVATION
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
�SYM. LEGEND
,
I II �I I, Ir-T T
I
O DENOTES MATERIAL
II II II -
-
I
I I 1I
III II I� �r � J J
DENOTES WINDOW NUMBER
i4 IT I
I I I ' ,
I
� (SEE SHEET AX.XX FOR
O
I _ III III III I '
; I
SCHEDULE)
1
>_ -- -
I_ II III
I-
LOUNGE ROOM DORMER GOOF
V
I
LOUNGE ROOM DORMER ROOF
V
III IIIL III III :III III II
I-� I
LTI1
1 ,- _.I II II II III�T
O
MATERIALS
IIII
_ CLUBHOUSE ROOF BEARING
CLUBHOUSE LEASING ROOF
Il
I
-1 - -
CLUBHOUSE ROOF BEARING
-.-.-. _.
- CLUBHOUSE LEASING ROOF
— BEARING h
T
,-
I,
'Y
BEARING _h
11' _ 8,
_ _
-
11' - E Y
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
LJLJI
FIRsrF0_0 _�
- _
_'
_
FIRST
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
CLUBHOUSE
- WEST ELEVATION
CLUBHOUSE
- EAST
ELEVATION
M9 METAL COPING
O
1/8" = 1'-01,
1/8" = 1'-0"
PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
LOUNGE ROOM DORMER R_ ooF
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
- - -
CLUBHOUSE ROOF BEARING
CLUBHOUSE LEASING ROOF
'-
BEARING
r
P5 LIGHT BRONZE - TBD
I
KEY PLAN
FIRST FLOOR
0'-0"
CLUBHOUSE - SOUTH ELEVATION
1/8" = 1'-0'
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
L.L
Q
nG
O
w
W
Z
o
—O
�
U
Z
LLII
^O
L.L
L.f�
ZOLLI
O
m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
EXTERIOR
ELEVATIONS -
CLUBHOUSE
A2.06
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
r
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
L ~ .
DESIGNS.
T
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
— — — — — —
— — — — —
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
N
BE BASIS OF DESIGN SPECIFICATIONS.
0
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
co
FINISH INSTALLATION.
e
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
\
/
DETAILS & MANU. RECOMMENDATIONS.
FIRSTFLoo.R
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
o' o
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
POOLHOUSE
- EAST
E L E VAT I O N
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
1/8" = 1'-O"
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
�SYM. LEGEND
ODENOTES MATERIAL
c
ODENOTES WINDOW NUMBER
(SEE SHEET AX.XX FOR
SCHEDULE)
MATERIALS
POOLHOUSE ROOF BEARING
POOLHOUSE ROOF BEARING
M1 VENEER RUNNING STONE U G BOND
N
o w
o
M2 FIBER CEMENT LAP SIDING
ih
777FIRsrFLOOR_�
M3 FIBER CEMENT BOARD AND BATTEN
o
FIRST FLo
oOR
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
POOLHOUSE - NORTH
ELEVATION
POOLHOUSE -
SOUTH
N[2]
M9 METAL COPING
1/6 = 1'-0'
1/8" = 1'-01,
PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
aO
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
❑
KEY PLAN
/ /
FIRST FLOO- R /
_.
0'
POOLHOUSE - WEST ELEVATION❑
1/8' = 1'_
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
a_
D
O
W
w
z
z
D
o
—O
�
U
z_
NW
^O
L.L
L.f�
OLLI
z
O
m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
EXTERIOR
ELEVATIONS -
POOLHOUSE
A2.07
ROOF BEARIN_.._ G_ /�.
30' - 5 114" V
THIRD FLOOR
2r-4" T
SECOND FLOG. R h_
FIRST FLOO.__. R h.
0'-0" V
BUILDING B (M) - NORTH ELEVATION 4
ROOF BEARING h
30'-5114" T
THIRD FLOOR h
21' - 4" T
SECOND FLOO._...
FIRST FLOORT h
0'-0"
BUILDING B (M) - WEST ELEVATION 3 _ BUILDING B (M) - EAST ELEVATION 2
1/8,, = 1'-0"
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
SYM. LEGEND
ODENOTES MATERIAL
ODENOTES WINDOW NUMBER
(SEE SHEET AX.XX FOR
SCHEDULE)
O 1 MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
M9 METAL COPING
O I PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
KEY PLAN
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
O
�Ir
V
I—
Z
CW
G Q
a_ >
O
w I-
Z
W D
o —O
� U
Z W
O
a� L.f�
_ /r
ZOLLI
O m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
BUILDING B (M) - SOUTH ELEVATION Li
1/8' — 1'-0'
EXTERIOR
ELEVATIONS -
BUILDING B
MIRRORED
A2.08
ROOF BEARING h
3a-51/4" T
THIRD FLO. OR. �.
zr_4 V
SECOND FLOOR d.
10' - 8" w
FIRSTFLOOR h
0'_0" 7
BASEMENT LEV.. EL �.
70'_8" V
BUILDING D (M) - WEST ELEVATION 3
MIHINININHIN
ROOF BEARING $
3a-51/4" T
THIRD FLOO... R h
— 21' - 4" Y
SECOND FLOOR h
1a-8"
FIRST FLOG_ R ,L
a -a V
BASEMENT LEVEL �...
BUILDING D (M) - NORTH ELEVATION
1/8' — V-0' O
zazz z zr-- =r r r r— _ _ _ _ _
z �S ����_�_�� -r r= ——rrrrrrrrr ---------------- � � z z z z
-- —zzr�r r=
---- � z = r _Yir__ _ ====z z=
—�= 3 rrrrrrrrrrrrrr_ QOON�O�
—_—_---sssa I — - � I i ■
II
i� -Iiii■unh■ if Ii1ii
--n nmm I ii1— 1 1I - � ■■ ■■ ••!!6 IIInnllrn,l �_ �I- ..-
_ROOF BEARING $L
3a Br
51/4" `I
THIRD FL OR
R.
—21'-4" V
SECOND FL00 Rom
1a-8" V.
FIRST FLOOR
a_0"
Illll■■II=I!1=1511111=111III F011I■I
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%. a
ISYM. LEGEND
ODENOTES MATERIAL
ODENOTES WINDOW NUMBER
(SEE SHEET AX.XX FOR
SCHEDULE)
O 1 MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
BUILDING D (M) - EAST ELEVATION 2 O
M9 METAL COPING
BASEMENT LEVE.. L h.
_10• _ g• V
ROOF BEARING &
3a-5
THIRD FLO
21' - 4" YOR h
_ SECOND FLOOR h
1
FIRSTFLOOR t,
p1_0 q
O PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
KEY PLAN
01 16N
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
BUILDING D (M) - SOUTH ELEVATION❑
1 /8" = V-0'
EXTERIOR
ELEVATIONS -
BUILDING D
MIRRORED
CLINE
GEN. NOTES
1. .:....
.. FROBUILDING IS M ..
PROVIDE
BUI
G ADDRESS IN 6" HIGH LETTERS
TO BE -. . BY FIRE MARSHALL. ADDRESS
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES NUMBERS TO BE ILLUMINATED.
-
WALKWAYS ELEVATED MORE THAN I
VERTICAL RISE TO HAVE MINIMUM T-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
mm m m m3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION.CONTACT
�Iw■ Ja-1--- -Z—ri--�iIIlwl■.■-I--_iSi-i--Za�'I— i—i_i_—_a`_T_--w_—ry—aa�`�_+w��i_—i-_—._iw—li_—ii—iiwiy—aI`I—I:— IZya�`-—�---r--.--Z--a�w-rrr���----itZrr__�—y�w•
ARCHITECT il-rl• • DETAILS DUE
l-- �yMINIMrrrrrrTO PRODUCT•
_w __ G--i
aia -Twain rw—%--� - ■ Iw-..
%i-�r�i---iiZ��iZ�Z�rra�a�-iii■-ia-ia�Ziia�Z�i�ia��--��■��a�=a�ia-ra�■1-�iriZli-a!+�_ PROVIDE
aiy ■1w- i-iw iyiii iattyyarta�wZa->•■Mitt. Ii�wrZiYZiZi-'i�i^' iyrLT---■y--�IaVa�yZi°i-TRANSITIONS Z. rw--all-wrw--w�ili-=1.� r.�aZw- i i yi a�lyw a\
--y----+' -----yyzr=--1---w-- +---rrriZri.�rw.-.�i F -
='Z-�■�--Z—I---w—J---- y T--Ir--+—Z y-fir—T—-----+--�"ar+-- y y
------11---ME SIEMENS
y---y--------z---y-----------y------•--------
a1��r_Zirrwriiii�iwY.rr�l-��-ylZ+wit-7�'I�riYrriZir-ZZZZir+-�.lZ+rrl�ar-rw-lei.°
- -i■ w- wwala+
■I� a- lii--ww-aV-w-aw�w--ai■-a�wa✓•-w-i-a- i-- a-� �iii�a�iiiaLiii.P.�s = -
a■I Zwiii-1 wilily---lyiwiw-ywiii+r-�. ..---w-ly--•-yy--r ■lal.Iir■ �_i_iii_i_ii;iiiiiii-asiia�ilia�iii�ia� a�iiiiiia- �iiiiia�a■I yrrr. •.. • - •MOISTURE
,at_a✓•la-ii-�I-a�-wZ-a��ar Z--wZZ-a�-a�IZZZi a� iiii iii i liit•'ia�ii--
y r+iw-. Z—wr-a. �iwiyia�a■lyl+i-
MMIa -- TI_.-.-.iii_ii_ii_i •� •
-- w --��a iii -■. 1iw i�l-I- - yal-
��_. - -�-ii ww ii i i-i i i i i a`- ww■�1 Zw� -� �I - is -
■la' 3 iii i�i•aiiZaL�iri aiiit✓iii iiaLil a�- �I - CORNERS•
a■-Zwla�-i la�iiila�iii�a�iiilarii ■f•ila�ii--a�ii:
•I' �rrl�-rrrriZwr�-.�Z1-ri�-�e-r i - --- ` mow- . yl-
I--i----y--------y---r�rzaee.= ZT—z� ,�yyYr.�ia���L7. -- -i i-IN -- i i i - i - i i--�� �° PROVIDE CONT.. • OVER
yr= r==Yi==:�rlr���-y=Y�r i M�yS�Z+ ya
- -- -------iii-- ----iiiw-- - ii-- iii---
-�.—=-rri—rrri— =—�-rHEATHING - TYVEK "COMMERCIAL WRAP" TO
yi-----sZ� =--BE BASIS OF DESIGN SPECIFICATIONS.
•"a+iiw-- --w -- yNr-- :.5'f■LT..Z� y-l=. SURFACES _a.:.wr--Z�,.�.CC�LL--%-C---� � _
a--_-■fir---�.�---,�--Iw-a_-_r .1.�.0�_ `a,-w BD...SYSTEM • •
AT ALL WALL
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
MEN NIEMEN
AT DUCT
MEN NIEMEN
Nor—�—_-_IIMEN NIEMENII III IIIMEN NIEMEN__ —■— _1111�111_ NONEMEMO
_IN _—_ -
■� _ aI 7
_ IIII���IIII — ■ a I� I� IJ ■ NN IIIIII-iillili�—=I1 I..i.i.i.— LEI 10 ■ ■■ PAPER BARRIER AND ONE LAYER BUILDING
:WEATHE-
IIi.I....::..::..::..... II SEALANT AT VERTICAL TRANSITIONS
f�i� 1111111111uulllllrlll Hill ! ! 11111111111�111111111111111111111111111111�11 ! 1 _—on I BETWEEN WALL FINISHES.
n-IiRD EL 0
21 zr-4 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
-a
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
SECOND FLOOR h
19-81, V
FIRS-TFL. __OR h
a_o. V
BUILDING B - WEST ELEVATION - ENLARGED 2
■iaraw■� NINE-
l yy+ r i ���-- •aa �-��: yl6 .aa _ _ _.Jw_w_Z-yw_w_wa✓. __ _ r ___
aL-w.��■ir�..�__:����---iw--w �w-w--w ywwwwww■tg._---w----,_
--- .www - -■-- .Lrrwiwwlwww rr..�w—iw--- ■-w-waLwwY.Ly..--.Llw-w-L--�- . y-waL-wl
---:a✓•—w—a✓• wa-ww.—aJ--�w--ww—w�wwia�—�ww wwwwwwwwwwa�waLww�iia�.---wwi—aiT�iww�lr-—wwwwwww�w®I
—=Zy---r--11—---y---1--------1y--°—il-----1y--1-1y--Zy---1y---1y----------r+1i--+1i--Zi,�
-1---� rrrr-----_ -----1--- ------ — w------rr ---- - —1-- rrr—y=-
SIEMENS
—r :y-w-aL--a-w!i -iy-Zii-ia�i----Za1■yw�-wwlwr■- wwyw-wwww i--ila■ -- a- wlwww- -w
---�-�---�---w--+1�-+°-y---+�wwrW�Z,--y---�wrr+---�c+�i-ww�ir��w
----:ala---a`w-a--w wai■iww iwilii - w-■al■----w---■lalaw--al■w waLwww.�wiwaLwlwwww w-w-alawwwaVMil
---yii-�-w-----'-I�-w--1-y---wy--1-y---yww----`---1----------�_li-■ _wl�--wy---y--
■ wwMINIMw w ■yww' w-I -■ w y II -I y
�Z—��r---y--� --z-- —z
i—_—,.yi--- i-------- i+r—yr--+r--s----_yi—r—r S _r i iyr -w.- -ate- a� I +wwww--w1a�-wila�-- wwla■ w I� -w www ---I w--I ■a. -ii - - --ate -ate ■.
-} - ■ www�yww-�i■r w�yywwwwww+www��wwwwyww�-iawww �,y �1■aia1 wr yw wyyyww�rllwwwr.�� --wwww- ly wwJaywwr y�-
}ZaL1�+�ww�wwwwa`www wwwwwwwa`ww--a-�r�waT�Tww�.w�w�wyawaLwwwwwwywwls �w-a��wi �ywwwyaTies
www---wl--�-
--->.,y-w-yy---w-'y----yi.--==-Lrr= w--y---- ---w
i-wwwy-L ZZyia�ry= ==-i-------w--+I-y-L==-■ar-r-y---yww- �w--y_--r '+w y-----
"ii-' yi--'ii-- -�yl iy—i-- �----�—r�1--+ Y-il - r>:,i--ai�y�rwi---w `Ti' ■wwi T� -cyw� rlMINI 0 11i■TwT�wTwi==r-�-==- =--� = y--==y=®! Ti-s�� �T��wilY4G
��`■� .�.�yira �yi- - �--1-yiiii'�--1-yi-iy---yii-+-----iiwy-w-�-wl-I�w-w■ - wi--I
- F� �� -w w- wwwww-■ MINIM ]MINI
w-■��wwi wia�wwww■- -ea- awl wwy-
_ia-i.%-i-yala-rwT_■Tii■---ia-il-Iw-ii-ww_: wwwwwwwl -._-i-wl�i3�G--wwwia-i--i-wwwwwlw�
arm
IiL-�--'� Fwa�-ilwwia--i-, w Zl�or la■ ww w Iww ■a�.�s�w wwww wE.... ®--ia�ra�. �rli
1=01
---at www--■--.c -I■r www -i- -MIMI o ■--w
r y i �wr a= wwl Iwyi■rw■ iilaa wr-lawi- -haw-ia�w p '-.A■I■■w -wY IV
=w,w9�_�_w�_■�____ ! --- `sr :-1a���Mir wwrw--- _icwwlw�ww- •�r�rrl����ilnJlr
iw�y-.--wy-w-wyaal--
-" -r--a✓•---a✓• ' -- 1 lia✓•y-.-w y = y� -- -.s- www ---e Iwyw.-wyw�wy1�_lw�
MENNEN
4
III MENNEN I I 1
—_I__IIIIIIJ� —■�1I --DI III NJ— -IIIIII -
- I _ 1 —
MENEM
O— - I __ -- I
- I — IaI 1 IaI
'III 0 LNJ 11�� M-�� 1...�.� ,.�...,.�.�.�.�.�I r:, O IJ a 11111111= ����ti=������ �� ■ ICI 1�1 O
— - Z 11111111111111II1111111111 �11111111111111111111111111111111111111111111 I — _ I � 11111111111111
n11111r11IIIMIN 11111unlinMINIM111111111111111111111 _ 1 -
- - I � ...�.LL-•I I 1 r �— — "... ..L,..-.LL.LL..LL..LLIII •'•"" MINI
L.LLI - 1 •. ..•
— _ I �' '1_ �— —'_ 1
MINI-
- I � 1 u - I w-a ww LXIII _ 1 -
-._ I1_
I NONE
—— ' _1
-I—III III— — 1—III 11 --III III — ■ =IIII III
-
- _ I — � II I Ii11171111111111111111111111111i11111111111111111111111 1 -- — ' I II III II lllllll IIIIII IIIIII Illllil11111111111111111111 _ 1 -
-111111111111111111111111111111111111111111111111111111111111 1 -- IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII _1 -
- _ IIIIIIIIIIIIIIIIIIIIIIIIIIIIilllllllllllllllllllllllllllllll -1 -- IIIi111111111111111111111111111111111111111111111111111� _ 1 -
-111111111111111111�11111111111111111111111111111111111111 - � �— — : I�III1111I11111!1111111111111111111111111111111111111111 = I =
NIEMEN
-..ItIO..••.ItItI•.•ItI•I•••••••I••••I•••IIII -- 6.Ip•..•�.!..•R..•R..•••.•••.•••.••I
—._ I— 1• �— _I -
- _ lT�r_ r� '_ 1 —
- _ -! _1 -
- _ -=Evi — _1 —
__ Fill] III=_ _ 1 11111 III III I — — _lllllll_
— _ 1_ -- I — _1 _
— _ 1 _ �— I iwl _ 1 _
— _ IaI IaI I
1 1�1 ICI —_—_ ICI � I
—_1• I —_ 'I 1 _ —_� I-.Z"uuliu n-n min n■-nml.nml.nml _ 1 __
__I10 111�1111 �_ -IIIIIIIIIIIIIIIi1111111111111111111111111111111111111111_ _-1---__---- -__
____ ___________ n1111111u1111111nuunnnn11nn11111n11111u1111 - • __ _ __
.-11111111111111 II��*- < _� _e:�IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII _�_� ----�I
�-�■°-1111NIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIILIIIi11�11�°-I'� ��---�-I ='
�S`�. y ■ate-r--;ate--;a��-;�i-;--ice, _.___ - : 5-�aG--;ate--;awl-;ate -�r�-��--.� i■i _.___ ___ ____.____._ _.____.__._ �-�a--�-�r�-�r�-�i%=.� •.'
I I �
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
SYM. LEGEND
ODENOTES MATERIAL
ODENOTES WINDOW NUMBER
(SEE SHEET AX.XX FOR
SCHEDULE)
O 1 MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METALCANOPY
O
M8 FIBER CEMENT PANEL
M9 METAL COPING
O I PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
KEY PLAN
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
O
Ir
Lu
CG Q
a_ >
O
w I-
Z
W D
o —O
�0 U
Z W
O LL _j
a_
ZO
_ MW
O W
VJ
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
BUILDING B -EAST ELEVATION - ENLARGED 1
ENLARGED EXTERIOR
ELEVATIONS -
BUILDING B
III III =MM MmmMM=m
•No
III II
1 !!l W....r!ip
CLINE
1
W
ROOF BEARING h
30'
_ THIRD FLOOR
2
SECOND FLOOR
1
FIRST FLOOR h
0'-0
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM T-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
BASEMENT LEVEL It W
z
�SYM. LEGEND 3 0
w
N
W
K
XX DENOTES MATERIAL a
A
x 7
DENOTES WINDOW NUMBER z z
BUILDING C - WEST ELEVATION - ENLARGEDI*
O SCEHESHEET AX.XX DULE)FOR o ww
3 6 0 G Q
MATERIALS 3 O
❑ J
a
uj �-
M1 STONE VENEER, RUNNING BOND z
M2 M8 M8 M8 M6 M2 M5 M1 M8 'z W
M2 FIBER CEMENT LAP SIDING o Q O
P1 P4 P3 P1 P2 P4 P1 w
M3 FIBER CEMENT BOARD AND BATTEN
O U
a z W
J
M4 METAL STANDING SEAM ROOF 0 O
F
w
M5 ARCHITECTURAL SHINGLE ROOF a Lr1
L
O
z
- M6 PREFABRICATED METAL RAILING w z
ui
Li
m
M7 PREFABRICATED METALCANOPY � � J
w �/�
v� Q
M8 FIBER CEMENT PANEL
0
M9 METAL COPING
I LL
i
z
ROOF BEARINGNG & w
30' - 5 T mr,.
SEE
MINI
8
ky
THIRD FLOOR h
21 - 4" T
SECOND FLOOR 10'_8„ $
FIRST FLOOR h
0,_01 I
❑ I PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
KEY PLAN
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
BUILDING C -EAST ELEVATION - ENLARGED 1
ENLARGED EXTERIOR
ELEVATIONS -
BUILDING C
MOM
E-
CLINE
)OF BEARING h
30'114
FHIRD FLOOR $
2
JOND FLOOR ,$
i
FIRST FLOOR
-MEN T LEVEL h
40'-8"
BUILDING D - WEST ELEVATION - ENLARGED
2
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM T-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
SYM. LEGEND
ODENOTES MATERIAL
ODENOTES WINDOW NUMBER
(SEE SHEET AX.XX FOR
SCHEDULE)
O 1 MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
M9 METAL COPING
O I PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
KEY PLAN
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
O
Ir
I—
Z
CW
G Q
a_ >
O
w I-
Z
W D
o —O
� U
Z W
^O ry
L.L
ZOLLI
O m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
ENLARGED EXTERIOR
ELEVATIONS -
BUILDING D
BUILDING D - EAST ELEVATION - ENLARGED
1
A2.16
M5) C M2 ) ( M3) C M4 ) ( M2) ( M1
I.II" I r.I..n I. I. I. I.. f.:1.. i, i] T..
FEW
I Il:J:a 1.. 1 I.I Z I: r..1: 3:: 1 n If:e
00
I J I ::.: 1.. C I . I ::: 1. : 'I :....0 e'.
DO
ao
O
ROOF BEARING h
W - 5 114" `I
THIRD FLD012 h
21'-44•
TOWNHOME A - NORTH ELEVATION - ENLARGED
F2
3/16" = V-0'
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
SYM. LEGEND
ODENOTES MATERIAL
ODENOTES WINDOW NUMBER
(SEE SHEET AX.XX FOR
SCHEDULE)
O 1 MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
M9 METAL COPING
O I PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
KEY PLAN
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
O
Ir
I—
Z
Lu
G Q
a_ >
O
w I-
Z
W D
o —O
�0 U
Z W
O LL _j
a_
ZOO
LLI
O m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
TOWNHOME A - SOUTH ELEVATION - ENLARGED
ENLARGED EXTERIOR
ELEVATIONS -
TOWNHOME A
TOWNHOME A - WEST ELEVATION - ENLARGED
2
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM T-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
SYM. LEGEND
ODENOTES MATERIAL
ODENOTES WINDOW NUMBER
(SEE SHEET AX.XX FOR
SCHEDULE)
O 1 MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
M9 METAL COPING
O I PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
KEY PLAN
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
O
Ir
I—
Z
CW
G Q
a_ >
O
w I-
Z
W D
o —O
�0 U
Z W
O LL _j
a_
ZOO
LLI
O m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
TOWNHOME A - EAST ELEVATION - ENLARGED
1
ENLARGED EXTERIOR
ELEVATIONS -
TOWNHOME A
A2.18
M5
rr■lmU1.[■1169a:1
iON
ILE
LEN
N
M3
M4) ( M2
M1
1r■D0111.[■D69�:1
■ by z �r� yr. yr WE.
FEE i
�iy� R$E��_ _ ilL4aiiRlQt�i�!
■
■
i
■
a
���lEID, '� i �IEIM III 1:11:1
ie
tr■pp/lpL■D&Lm.
■
■
TOWNHOUSE B
ROOF BEARING 0�
THIRD FLOOR
2I'-Y
SECOND FLOOR h
FIRST FL_ OOR h
D• - 0" V
TOWNHOME B - NORTH ELEVATION - ENLARGED
3/16" = V-0'
TnWNHCH ICF R
Tr)%A/NH(ll ICF R
TCHA/NHni ICF R
TOWNH(N ICF R
ROOF BEARING Ab
30'-57/4' T
THIRD FLOOR
R h.
SECOND FLOOR h
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%. a
__]ISYM. LEGEND
ODENOTES MATERIAL
ODENOTES WINDOW NUMBER
(SEE SHEET AX.XX FOR
SCHEDULE)
O 1 MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
M9 METAL COPING
PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
KEY PLAN
01 16 N
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
JG
G�
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
TOWNHOME B - SOUTH ELEVATION - ENLARGED II
ENLARGED EXTERIOR
ELEVATIONS -
TOWNHOME B
A2.19
TOWNHOME B - WEST ELEVATION - ENLARGED
2
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM T-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
SYM. LEGEND
ODENOTES MATERIAL
ODENOTES WINDOW NUMBER
(SEE SHEET AX.XX FOR
SCHEDULE)
O 1 MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
M9 METAL COPING
O I PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
KEY PLAN
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
O
Ir
I—
Z
CW
G Q
a_ >
O
w I-
Z
W D
o —O
�0 U
Z W
O LL _j
a_
ZOO
LLI
O m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
TOWNHOME B - EAST ELEVATION - ENLARGED
1
ENLARGED EXTERIOR
ELEVATIONS -
TOWNHOME B
A2.20
N DORMER ROOF
E ROOF BEARING
m_T
IE LEASING ROOF
BEARING
11'-6" T
FIRST FLOOR h
0•-0" V
CLUBHOUSE - NORTH ELEVATION - ENLARGED❑
3/16' = V-0'
LOUNGE ROOM DORMER ROOF
18'-0" V
CLUBHOUSE ROOF BEARING h
it -n-n-
CLUBHOUSE LEASING ROOF
BEARING
it BEARING
FIRST FLOOR h
0' OR V
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
SYM. LEGEND
ODENOTES MATERIAL
ODENOTES WINDOW NUMBER
(SEE SHEET AX.XX FOR
SCHEDULE)
O 1 MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
M9 METAL COPING
O I PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
KEY PLAN
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
O
tr
G
Q
a_
>
O
w
I-
W
Z
D
o
—O
�
U
Z
W
^O
L.L
ry
ZOLLI
O
m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
CLUBHOUSE - SOUTH ELEVATION - ENLARGED
3/16" = 1'-0'
ENLARGED EXTERIOR
ELEVATIONS -
CLUBHOUSE
A2.21
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
M3 M5 M5
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
P'I P4 P4
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
LT-LT-1
DETAILS & MANU. RECOMMENDATIONS.
I
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
LOUNGE ROOM DORMER ROOF �,
WEATHER BARRIER AND ONE LAYER BUILDING
78
PAPER
- - - - -
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
CLUBHOUSE ROOF BEARING
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
CLUBHOUSE LEASING ROOF
e�
ELIMINATED.
m-e•
-
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
_
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
ILL[ I i
FIRST FLOOR h
�SYM.
LEGEND
ODENOTES MATERIAL
-
WEST ELEVATION
- ENLARGED
OR NUMBER
DENOTECLUBHOUSE
2
SCHEDULE)
SCHEDULE)
0
MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M2 M5 M1
M7 PREFABRICATED METAL CANOPY
P1 P4
M8 FIBER CEMENT PANEL
M9 METAL COPING
_ LOUNGE ROOM DORMER ROOF „
_ _
7
PAINT COLORS
P1 EXTRA WHITE - SW7006
- - CLUBHOUSE ROOF BEARING h
CLUBHOUSE LEASING ROOF
BEARING
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
-
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
FIRST FLOOR
T
0'_0•
11
KEY PLAN
CLUBHOUSE
- EAST ELEVATION
- ENLARGED
3/16" = 1'-0'
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
Illy
G
Q
a_
>
O
w
I-
W
Z
D
o
—O
�
U
Z
W
O
�
a_
L.f�
ZOLLI
O
m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: DATE
DRAWN BY: CW, INS, RES
CHECKED BY: JL
ENLARGED EXTERIOR
ELEVATIONS -
CLUBHOUSE
A2.22
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
M8 M5 M2 M4 M8
M1
VERTICAL RISE TO HAVE MINIMUM 3'-6"HIGH
GUARDRAILS AS PER THE BUILDING CODE.
P1 P4 P1 P5 P3
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
-_ - - --
DETAILS & MANU. RECOMMENDATIONS.
- -- p- - - -
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
`'=��
T�r
11. INSTALL STONE VENEER OVER ONE LAYER
-- - - - -
WEATHER BARRIER AND ONE LAYER BUILDING
- - -- - - - - -- - -- __
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
I
EXCEED30%.
FIRST FLOG.._.. R. h
0'-0" Y
�SYM.
LEGEND
ODENOTES MATERIAL
POOLHOUSE - WEST ELEVATION -
ENLARGED
O (SEEOSHET'AXOX OR NUMBER
2
SCHEDULE)
0
MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M1 M8 M8 M5 M4 M2 M8
M7 PREFABRICATED METAL CANOPY
P1 P3 P4 P5 P1 P1
M8 FIBER CEMENT PANEL
M9 METAL COPING
- -„ , 11 -
PAINT COLORS
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
❑
KEY PLAN
-
FIRST FLOOR
0'-0"
POOLHOUSE - EAST ELEVATION -
ENLARGED
3/16" = 1'-0'
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
ry
G
Q
a_
>
O
w
I-
W
Z
D
o
—O
�
U
Z
W
O
�
a_
L.f�
ZOO
LLI
O
m
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, INS, RES
CHECKED BY: JL
ENLARGED EXTERIOR
ELEVATIONS -
POOLHOUSE
A2.23
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
M5 M8 M1 M2
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
P4 P1 P3
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
-
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
- - _ ._ _ _- _
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
- -I I I -I I i I I I
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
_ _ POOLHOUSE ROOF BEARING
13,-a" T
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
FIZI
EXCEED30%.
FIRSTFLOO. R h
__
0' - 0' Y
�SYM.
LEGEND
ODENOTES MATERIAL
POOLHOUSE - SOUTH
ELEVATION
- ENLARGED
O (SEEOSHET'AXOX OR NUMBER
[2]
SCHEDULE)
3/16"
0
MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
M9 METAL COPING
M1 M5 M8
P4 P1
IILL
PAINT COLORS
P1 EXTRA WHITE - SW7006
_ POOLHOUSE ROOF BEARING
GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
0 ,
FIRST FLOOR /
KEY PLAN
0' - 0"
POOLHOUSE - NORTH
ELEVATION
- ENLARGED
3/16" = V-0'
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
Illy
G
Q
a_
>
O
w
>:
I-
W
Z
D
o
—O
U
Z
W
O
�
a_
L.f�
ZOO
LLI
O
m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, INS, RES
CHECKED BY: JL
ENLARGED EXTERIOR
ELEVATIONS -
POOLHOUSE
A2.24
CLINE
r
M2 M8
P1 P4 P1
I■IIIm
M8
P3
R
M6
M2
a
M1 ) C M5
M8
P1
171
Fill]
OOF BEARING h
30'-5iw T
THIRD FLOOR
O....R h
21'V
-COND FLOOR
FIRSTFLOOR
0-0., T
BUILDING B (M) - WEST ELEVATION - ENLARGED L2j
3/16'
ROOF BEARING h
30'-51/4' T
THIRD FLOOR h
21' - 4" I
SECOND FLOOR
R h
10'-8' Y
FIRST FLOO. R h
0'-0" Y
GEN. NOTES
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
PAPER
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
NOT DROP BELOW 40%.
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED30%.
SYM. LEGEND
ODENOTES MATERIAL
ODENOTES WINDOW NUMBER
(SEE SHEET AX.XX FOR
SCHEDULE)
❑ 1 MATERIALS
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
M3 FIBER CEMENT BOARD AND BATTEN
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
M9 METAL COPING
❑ I PAINT COLORS
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
P5 LIGHT BRONZE - TBD
KEY PLAN
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
O
ry
I-
Z
Lu
G Q
a_ >
O
w I-
Z
W D
o —O
� U
Z W
^O ry
L.L
ZOLLI
O m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
BUILDING B (M) - EAST ELEVATION - ENLARGED 1
3/16" = 1'-0'
ENLARGED EXTERIOR
ELEVATIONS -
BUILDING B
MIRRORED
A2.26
III
III
�
NEI!
9
,NN
CLINE
GEN. NOTES
M2 M8
M8
M2 M8 M1
M6 M8
1. ADDRESSING SIGNAGE TO BE LOCATED ON THE
SIDE OF THE BUILDING FROM WHERE THE
P1 P4
P3
P2 P1
P1
BUILDING IS ADDRESSED (ONE SIDE ONLY).
PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS
TO BE APPROVED BY FIRE MARSHALL. ADDRESS
NUMBERS TO BE ILLUMINATED.
2. SEE WALL SECTIONS & ENLARGED ELEVATIONS
FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR
_
WALKWAYS ELEVATED MORE THAN 30" IN
VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH
--
—I KKK
GUARDRAILS AS PER THE BUILDING CODE.
3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR
MATERIALS. THE WALL SECTIONS AND DETAILS
SHOWN IN THIS SET REFLECT FIBER CEMENT
PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL
—
WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT
SUBSTITUTION IS MADE. CONTACT ARCHITECT IF
— —
THERE ARE ANY DISCREPANCIES IN DETAILS DUE
TO PRODUCT SUBSTITUTIONS.
ROOF BEARING h
30'-5 V4•
4. PROVIDE METAL FLASHING AT HORIZONTAL
TRANSITIONS BETWEEN WALL FINISHES.
❑
❑
—
5. SEE ROOF PLAN FOR OVERHANG DIAGRAM
DESIGNS.
D
El
[u]
6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE
BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE
CORNERS FULL HEIGHT OF WALL (TYP.)
—
7. PROVIDE CONT. BUILDING WRAP OVER
SHEATHING - TYVEK "COMMERCIAL WRAP" TO
BE BASIS OF DESIGN SPECIFICATIONS.
THIRD FLOOa__�
27 °
8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS
AT ALL WALL SURFACES PRIOR TO EXTERIOR
FINISH INSTALLATION.
I
Ji
—
El L
❑
9. TERM./FLASH BUILDING WRAP AT PENETRATIONS
DETAILS & MANU. RECOMMENDATIONS.
10. PROVIDE PRE-FAB. FLASHING BOOTS OR
FLANGED EXHAUST LOUVER AT DUCT
PENETRATIONS AT WALLS (TYP).
—
11. INSTALL STONE VENEER OVER ONE LAYER
WEATHER BARRIER AND ONE LAYER BUILDING
—
PAPER
SECOND F70' 8"Lo 8 —�
12. PROVIDE SEALANT AT VERTICAL TRANSITIONS
BETWEEN WALL FINISHES.
❑
❑
13. VISIBILITY OF ALL MECHANICAL EQUIPMENT
FROM THE ENTRANCE CORRIDOR SHALL BE
ELIMINATED.
VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL
14. u
NOT DROP BELOW 40 /o.
_
15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT
EXCEED 30%.
FIRST FLOOR. /
0' - 0" V
O
O
❑
O O
i
BASEMENT LEVEL. /
—10-8" V
�SYM. LEGEND
ODENOTES MATERIAL
BUILDING D (M) - WEST ELEVATION
- ENLARGED
O (SEEOSHEOR NUMBER
2
SCHEDULE)T'AXOX
3/16" = 1'-0"
M5
M2
M8
M6 M2 M1
M8 M8
M8 M6
O
MATERIALS
P4
P1
P3
P2
P4 P1
P1
M1 STONE VENEER, RUNNING BOND
M2 FIBER CEMENT LAP SIDING
FIBER CEMENT BOARD AND BATTEN
---
-
-
M4 METAL STANDING SEAM ROOF
M5 ARCHITECTURAL SHINGLE ROOF
M6 PREFABRICATED METAL RAILING
M7 PREFABRICATED METAL CANOPY
M8 FIBER CEMENT PANEL
❑
❑
_ ROOF BEARIN. G h
30'-51/4" V
M9 METAL COPING
Li
ow
—
THIRD FLOOR h
21 _ 4...T
TIE
PAINT COLORS
SECOND FLOOR
10,_8 Y
■
� O
� O
■
O ®
P1 EXTRA WHITE - SW7006
P2 GRAY SCREEN - SW7071
a
P3 ROYCROFT PEWTER - SW2648
P4 SMOKY BLUE - SW7604
- FIRSTFLOOR -h.
0'-0. Y
P5 LIGHT BRONZE - TBD
O O
■
O O
J
KEY PLAN
-
BASEMENT LEVE..L
_19_81 Y
BUILDING D (M) - EAST ELEVATION
- ENLARGED❑
3/16" = 1'-0'
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
n
D
ry
G
Q
O
�-
W
W
Z
D
o
—O
�
U
Z
W
00.
L.L
_j
ZOO
LLI
O
m
v!
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: I DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
ENLARGED EXTERIOR
ELEVATIONS -
BUILDING D
MIRRORED
A2.28
AMENITY DOOR SCHEDULE
DOOR #
DOOR INFORMATION
FRAME INFORMATION
FIRE RATING
HARDWARE
SET
COMMEN ZS
HEIGHT
WIDTH
THICKNESS
DOOR TYPE
DOOR
MATERIAL
FRAME TYPE
FRAME
MATERIAL
FRAME DETAILS
HEAD DETAIL
JAMB DETAIL
SILL DETAIL
1778
7' - 0"
3' - 0"
13/4"
F
HM
01
HM
2055
8.-0..
2'- 6"
13/4"
F
HM
01
HM
2077
8' - 0"
2'- 6"
13/4"
F
HM
01
HM
2080
8' - 0"
2'-6"
13/4"
F
HM
01
HM
2081
8' - 0"
2'-6"
13/4"
F
HM
01
HIM
2082
8' - 0"
2'-6"
13/4"
F
HM
01
HM
3460
8' - 0"
3' - 0"
13/4"
F
HM
01
HM
4611
7' - 0"
3' - 0"
13/4"
F
HM
01
HIM
4613
7'-0"
3' - 0"
13/4"
F
HM
01
HM
-
4618
7'- 0"
3'- 0"
13/4"
F
H M
01
HM
-
6864
8' - 0"
3'- 0"
13/4"
F
HM
01
HM
-
6867
7'- 0"
3' - 0"
13/4"
F
HM
01
HM
-
6868
8' - 0"
2'- 6"
13/4"
F
HM
01
HM
6870
7'- 0"
3' - 0"
13/4"
F
HM
01
HM
6871
8' - 0"
2'-6"
13/4"
F
HM
01
HM
6872
8' - 0"
2'-6"
13/4"
F
HM
01
HM
6873
8' - 0"
2' - 6"
13/4"
F
HM
01
HM
A105
8'-0"
3'-0"
13/4"
F
HM
01
HM
-
A115
8'-0"
3'-0"
13/4"
F
HM
01
HM
-
A116
8' - 0"
3'- 0"
13/4"
F
I HM
01
HM
A117
8' - 0"
3' - 0"
13/4"
G
I unn lni
unn
-
-
A118
8' - 0"
3' - 0"
13/4"
A119
8.-0..
3'- 0"
13/4"
/-REVIEW
COMMON DOOR SCHEDULE
DOOR #
DOOR INFORMATION
FRAME INFORMATION
FIRE RATING
HARDWARE SET
COMMENTS
EIGHT
WIDTH
THICKNESS
DOOR TYPE
DOOR MATERIAL
FRAME TYPE
FRAME MATERIAL
7'-0"
6'-0"
13/4"
2F
HM
01
HM
A123
8'-0"
6'-0"
13/4"
2F
HM
01
HM
CO3
7'-0"
13/4"
FFG
WD
03
WD
LAKEHOUSE SCREEN DOOR
C04
13/4"
FFG
AL
01
AL
STOREFRONT
C05
7' - 0"
3'- 0"
13/4"
F
HM
01
HM
U
7'-0"
3'-0"
13/4"
F
HM
01
HM
APARTMENT STORAGE DOOR
110
8'- 0"
9'- 0"
13/4"
1 OH2
I HM
102
1 HM
I
IUHW-7
I GARAGE DOORS - CARRIAGE HOUSE
I
UNIT DOOR SCHEDULE
DOOR#
DOOR INFORMATION
FRAME INFORMATION
FIRERATING
HARDWARE
SET
COMMENTS
HEIGHT
WIDTH
THICKNESS
DOORTYPE
DOORMATERIAL
FRAMETYPE
FRAMEMATERIAL
U01
7' -0"
3' - 0"
13/4"
1P
WD
03
MSJ*
20 MIN.
UHW-1
UNIT ENTRY (SINGLE)
UO2
7'-0"
3'-0"
13/4"
1P
WD
01
WD
20MIN.
UHW-1
UNIT ENTRY DOOR
U05
7' - 0"
2'- 10"
13/4"
1P
WD
03
WD
9
CLOSET (SINGLE - PASSAGE)
U06
7'-0"
2--10"
13/4"
1P
WD
03
WD
10
BDRM/BATH (SINGLE - PRIVACY)
U07
6'- 8"
2--10"
13/4"
2P
WD
03
WD
4
BDRM/BATH (SINGLE - PRIVACY)
U14
6'- 8"
1' - 6"
13/4"
ZP
WD
03
WD
3
CLOSET (SINGLE - PASSAGE)
U15
6'-8"
2'- 10"
13/4"
2P
WD
03
WD
3
CLOSET (SINGLE - PASSAGE)
U16
7'-0"
2'-4"
13/4"
1P
WD
03
WD
9
CLOSET (SINGLE)
U17
6'-8"
4'-0"
13/4"
2P1P
WD
03
WD
18
CLOSET DOUBLE
U18
6'-8"
5'-0"
13/4"
2P1P
WD
03
WD
18
CLOSET DOUBLE
U19
6'-8"
5'-4"
13/4"
2P1P
WD
03
WD
-
18
CLOSET DOUBLE
U34
8' - 0"
3'- 0"
13/4"
FG-T
-
--
-
BALCONY (SINGLE) W/ TRANSOM
U44
6' - 8"
2' -10"
13/4"
2P
WD
03
WD
5
WH/AH (SINGLE - LOCK)
U58
7'-0"
3'-0"
13/4"
F
HM
01
HM
-
APARTMENT STORAGE DOOR
U110
8'-0"
9.-0..
13/4"
OH2
HM
02
HM
7
GARAGE DOORS - CARRIAGE HOUSE
U111
7'- 0"
9.-0..
OH1
GARAGE DOOR - CRAFTSMAN
U116
8'-0"
7'-0"
1 13/4"
1
1
1
SLIDING BALCONY DOOR 6-8 H
SET #1
SET #2
SET #3
SET #4
6
Hinge
3
Spring Hinge
3
Hinge
6
Hinges
2
Panic Hardware
1
Lockset
1
Lockset
2
Flush Bolt
2
PA Closer
1
Cylinder Core
1
Cylinder Core
1
Lockset
2
Kick Plate
1
Wall Bumper
1
Gasketing
1
Cylinder Core
1
Gasketing
1
Gasketing
1
DeadBolt
1
PA/Stop Closer
1
Astragal Set
1
Overhead Door Stop
1
Brush Sweep
1
Astragal Set
1
Neoprene Gasketing
1
Saddle Threshold
SET #5
SET #6
SET #7
SET #8
3
Hinge
3
Hinge
6
Hinge
3
Hinge
1
Panic Hardware
1
Panic Hardware
2
Lockset
1
Lockset
1
Kick Plate
1
Kick Plate
2
DeadBolt
1
DeadBolt
1
Gasketing
1
Gasketing
2
Kick Plate
1
Kick Plate
1
Wall Bumper
2
Wall Bumper
1
Wall Bumper
1
Coordinator
1
Astragal Set
SET #9
SET #10
SET #11
SET #12
3
Hinge
3
Hinge
1
Sliding Door Track
6
Hinge
1
Passage Set
1
Privacy Set
2
Door Stops
2
Gasketing
1
Wall Bumper
1
Wall Bumper
1
Door Guides
1
Astragal Set
SET #13
SET #14
3
Hinge
3
Hinge
1
Lock Set
1
Fire Exit Device
1
Cylinder Core
2
PA Closer
1
Wall Bumper
1
Gasketing
1
Lockset or Card
Access
SET #17
1
Cylinder core
6
Hinge
SET #18
2
Panic Hardware
6
Hinge
2
PA Closer
2
Dummy Levers
2
Kick Plate
2
Wall Bumpers
1
Gasketing
2
Ball Catches
1
Astragal Set
1
Coordinator
1
Saddle Threshold
2
Brush Sweeps
1
Lockset
SET #15
1 Track
1 Pocket Door
1 Lock Set
SET #16
2 Track
2 Pocket Door
Pasage Set
NOTES:
1. DOOR MANUFACTURER TO PRECUT DOOR TO ACCOMODATE ELECTRIC STRIKE AND ELECTRIC MORTISE.
2.SEE SCHEDULE FOR ADDITIONAL SECURITY REQUIREMENTS. STAIRWAY DOORS TO COMPLY WITH 403.5.3 IF LOCKED FOR
SECURITY.
3. DOORS ENCLOSING FIRE SERVICE ACCESS ELEVATOR LOBBY SHALL ALSO COMPLY WITH UL 1784 TEST CONDUCTED
WITHOUT ARTIFICIAL BOTTOM SEAL.
4. FIRE DOOR ASSEMBLIES SHALL MEET SMOKE AND DRAFT CONTROL REQUIREMENTS PER 2017 FLBC SECTION 715. FIRE
DOORS SHALL ALSO MEET GLAZING SIZE LIMITATIONS PER NFPA 80 AND TESTING REQUIREMENTS OF NFPA 252.
DOOR NOTES:
1. SEE FLOOR PLANS FOR SWING DIRECTION
2. SEE ENLARGED PLANS FOR DOOR TAGS
3. SEE LIFE SAFETY PLANS AND ID DRAWINGS FOR DOORS AT CLUB AND LEASING
4. ALL DOOR CLOSERS AND SPRING HINGES AT RATED DOORS MUST BE NFPA 80
APPROVED
5. ALL PASSAGE DOORS AT TYPE'B' UNITS MUST BE MIN. 2'-10" WIDE. ALL PASSAGE
DOORS AT TYPE W UNITS AND COMMON AREAS MUST BE T-0" WIDE.
6. ALL PASSAGE DOORS AT COMMON AREAS MUST BE T-0" WIDE.
7. ALL INTERIOR UNIT PASSAGE DOORS MUST BE 2'10" WIDE.
8. PROVIDE TEMPERED GALSS IN ALL DOORS AS REQUIRED BY THE STATE BUILDING
CODE. T = TEMPERED GLASS.
9. EXTERIOR DOOR U VALUE AND SOLAR HEAT GAIN COEFFICIENT TO COMPLY WITH
THE NC BUILDING CODE.
10. ALL DOOR HARDWARE AT TYPE W UNITS AND COMMON AREAS TO COMPLY WITH
ICC At 17.1-2009 SECTION 404.2.6.
11. PROVIDE DOOR STOP AT ENTRY DOOR AND ANY OTHER DOOR THAT SWINGS INTO
A WALL OR CABINET.
12. G.C.TO COORDINATE ALL SECURITY REQUIREMENTS BY OWNER WITH DOOR
FRAMES.
13. G.C. TO COORDINATE FRAME SIZE WITH DOOR MANUFACTURER REQUIREMENTS.
14. ALL GLASS IN DOORS AND SIDELIGHTS TO BE TEMPERED.
15. IN ALL UNITS PROVIDE LOCKSETS @ BEDROOM & BATHROOM DOORS
16. PROVIDE PANIC HARDWARE ASSEMBLY AT ALL ELECTRICAL ROOM DOORS.
*METAL SPLIT JAMB - DOOR FRAME TO MEET REQUIRED FIRE RATING FOR DOOR
TEMPERED GLASS NOTES:
GLAZING IN INDIVIDUAL FIXED OR OPERABLE WINDOWS WITHIN A
2'-0" RADIUS OF A DOOR (OPEN OR CLOSED POSITION) THAT ARE IN
THE SAME WALL SHALL HAVE TEMPERED GLAZING UP TO A HEIGHT
OF 5'-0" ABOVE FINISHED FLOOR.
T.G = TEMPERED GLASS LOCATION
o 'TZ
r'T.G.
WIDTH I
WIDTH
( WIDTH
WIDTH
GLAZING SCHEDULE:
ti
-
w
_
_
_
To TEMPERED GLASS
_
w
W
uw
w
x
x
x
x
J
ui
J
J
J
W
W
W
�
CO
TYPE 01 TYPE 02 TYPE 03 TYPE 04
HOLLOW METAL HOLLOW METAL WOOD / ALUMINUM FRAME
FRAME FRAME METAL SPLIT
FRAME
E ELEVATIONS
SCHEDULED
DOOR TYPE ELEVATIONS
F
COMMERICAL / AMENITY
W
U
SCHEDULED Z
WIDTH
WIDTH
0
LD
/
\
W
_LLI
/
\
❑
❑w
J
�
❑
w
/
w
x
U
,
W
i
i
2P1P FG-T
(BALCONY DOOR)
amenity/common doors update
SCHEDULED WIDTH
Lrdl Ull.
x
C7
\
w
x
❑
W
J
w
U
/
/
w
J
�
w
x
U
U
1P 2SG
1 PANEL 2 PANEL SLIDING GLASS
Nz
2F NG 2NG
WINDOW NOTES:
1. SEE PLANS/ELEVATIONS FOR WINDOW TYPE LOCATIONS.
2. PROVIDE CASEMENT WINDOW AT TYPE W UNITS OPERABLE WINDOW
LOCATIONS. STYLE TO MATCH 'HUNG' WINDOWS.
3. OPERABLE WINDOWS PROVIDED AT TYPE W UNITS SHALL HAVE AT
LEAST ONE WINDOW IN EACH SLEEPING, LIVING OR DINING SPACE
WITH ACCESSIBLE CONTROLS AT 15" HIGH MINIMUM AND 48" HIGH
MAXIMUM.
4. PROVIDE TEMPERED GLASS AS REQUIRED BY THE STATE BUILDING
CODE.
5. ALL WINDOWS TO BE INSTALLED PER WINDOW INSTALLATION
DETAILS.
6. WINDOW U VALUE AND SOLAR HEAT GAIN COEFFICIENT TO COMPLY
WITH 2O12 NC ENERGY CONSERVATION CODE.
7. REFER TO STRUCTURAL SHEETS FOR WIND LOADS.
8. VINYL WINDOW COLOR: BRONZE
9. OPERABLE WINDOWS IN R-2 OCCUPANCIES SHALL COMPLY WITH
SECTIONS 1015.8 & 1015.8.1 OF THE 2018 NCBC.
10. ALL OPERABLE WINDOWS IN PROJECT MUST MEET REUIREMENTS
SET BY NCBC 1030.
11. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%.
12. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED 30%.
CD
v
v
M
x
(7
W
x
W
J
w
2
W
SCHEDULED WIDTH
OH1
(GARAGE CRAFTSMAN)
+ townhome door with sidelite
I]]
/ / El
HG 2HG
FG
SCHEDULED WIDTH
W
U
OH2
(GARAGE CARRIAGEHOUSE)
I F
2FG
DOOR AND FRAME TYPES 2
1/4" = V-0"
WINDOW SCHEDULE
Type Mark
Height Width
COMMENTS
Al
4'-8"
2'-6"
A2
6'-0"
2'-6"
A3
4'-8"
3'-0"
A4
6'-0"
T-0"
A5
4'-0"
V-6"
A6
4'-6"
2'-0"
A7
4'-0"
2'-0"
A8
T-0"
V-6"
A9
6'-0"
T-0"
A10
2'-0"
T-0"
C 5' - 10"
2" 2 3 3 1 _6" 3' - 0" 2'- 8" 6„ 2 _8„
8' HEAD HEIGHT
o
O (
f0 ❑ ❑ V
■co
o o 1 1 0
1
1 i0 1 b co
Ll
1 0 1
o Cl) o o
(V (V OT (V
Al O A3 A4 A5 A6 47 A8 A9 10 FLOOR LEVEL
WINDOW TYPE ELEVATIONS
DOOR SCHEDULE & HARDWARE SET [-3]
WINDOW TYPES
1/4" = 1'-0' 1/4" = 1'-0"
01 16N
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1ineDesignAssoc.com
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
DOOR / WINDOW
SCHEDULES
F�T9111 I
---.�aa—•0�00dommomm.—
VISIBILITY OF ALL MECHANICAL
EQUIPMENT FROM ENTRANCE
CORRIDOR SHALL BE ELIMINATED
�� i
220 E. Peterson Dr.
Charlotte, NC 28217
704/333-7272
C1incDcsigmkssoc.com
n
Z)
O�//
ry
V
Z
CW
a
^G
L.L
>
O
w
z
w
z
D
0
-O
U
z0
w
O
ry
�
Q
z0�
O
-
m
Q
U)
PROJECT: 221074
DATE: 09.26.2022
REVISIONS: DATE
DRAWN BY: CW, NS, RES
CHECKED BY: JL
ARCHITECTURAL SITE
PLAN
ARCHITECTURAL SITE PLAN❑ 1" = 50'-0'
G1.02