HomeMy WebLinkAboutARB202200066 Architectural Drawings 2022-10-18BUILDING B - WEST ELEVATION x L7 w x L9 z 0 J m BUILDING B - NORTH ELEVATION 4 BUILDING B - EAST ELEVATION 1/8" = 1'-0" x x z z D J_ n 2 GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. SYM. LEGEND ODENOTES MATERIAL ODENOTES WINDOW NUMBER (SEE SHEET AX.XX FOR SCHEDULE) O 1 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL M9 METAL COPING O I PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD KEY PLAN 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D O Ir I— Z CW G Q a_ > O w I- Z W D o —O �0 U Z W O LL _j a_ ZOO LLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, NS, RES CHECKED BY: JL BUILDING B - SOUTH ELEVATION 1 EXTERIOR ELEVATIONS - BUILDING B A2.01 00 0 ROOF BEARING h 30'-5114" / THIRD FLOOR h 21 _4 " V SECOND FLOO__ 10'-8" Y FIRST FLOO 0,_0. TR BUILDING C - NORTH ELEVATION 4 1/8" = 1'-0' BUILDING C - WEST ELEVATION 3 BUILDING C - EAST ELEVATION 2 1/8" GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. SYM. LEGEND ODENOTES MATERIAL ODENOTES WINDOW NUMBER (SEE SHEET AX.XX FOR SCHEDULE) O 1 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL M9 METAL COPING O I PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 x = P4 SMOKY BLUE - SW7604 z z P5 LIGHT BRONZE - TBD KEY PLAN 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D O Ir I— Z CW G Q a_ > O w I- Z W D o —O � U Z W ^O ry L.L ZOLLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, NS, RES CHECKED BY: JL EXTERIOR ELEVATIONS - BUILDING C BUILDING C - SOUTH ELEVATION 1/8" — 1'-0' A2.02 BUILDING D - WEST ELEVATION 3 1/8" = 1'-0. (7 w z z 0 J_ 00 m BUILDING D - NORTH ELEVATION 2 BUILDING D - EAST ELEVATION 2 1/8" = 1'-0" ROOF BEAR. B ING h 30'-51/4" V THIRD FLOOR h 27' - 4" SECOND FLOOR h wl FIRST FLOOR $ D•_Q' �I GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. SYM. LEGEND ODENOTES MATERIAL ODENOTES WINDOW NUMBER (SEE SHEET AX.XX FOR SCHEDULE) O 1 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL M9 METAL COPING O I PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD KEY PLAN 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D O tr Z CW G Q a_ > O w I- Z W D o —O �0 U Z W O LL -i a_ ZOO LLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, NS, RES CHECKED BY: JL BUILDING D - SOUTH ELEVATION 1/8" = 1'-01, 1 EXTERIOR ELEVATIONS - BUILDING D A2.03 ❑ GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN - T �4 4T1-4 __.J=r-r 4 VERTICAL RISE TO HAVE MINIMUM S'-6" HIGH ' - GUARDRAILS AS PER THE BUILDING CODE. I T z 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR jr _ z� MATERIALS. THE WALL SECTIONS AND DETAILS ��� � ul���r =� �' �� �Y SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH TRIM. ALL MATERIAL TO WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF — �-� ` ; � THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. - � = ROOF BEARING / 30' - 5 BEARING 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. ❑ F[E v 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE �* THIRD BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE rn — �FLOOR � 21 _4" r CORNERS FULL HEIGHT OF WALL (TYP.) I w d 7. PROVIDE CONT. BUILDING WRAP OVER "COMMERCIAL TO BE BASIS OF D SIGN SP CIFICAT O S. i b 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. = SECOND FLooR 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS a-S DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. TOWNHOME A- NORTH ELEVATION 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 4 118" = 1'- r 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. � ❑ SYM. LEGEND ROOF BEARIN�G T ROOF BEARING �T 30'-57/4" I 30'-51/4' ODENOTES MATERIAL m a, DENOTES WINDOW NUMBER It (SEE SHEET AX.XX FOR O THIRD FLOOD —21'-4„ V THIRD FLOOR V SCHEDULE) 21• 4•• ED FPT � o ■ d) o O ❑ MATERIALS �o II M SECOND FLOOR J, ECOND FLOOR=;;==I= = M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING co ao 0 o M3 FIBER CEMENT BOARD AND BATTEN FIRSTFLOOR — FIRSTFLOOR M4 METAL STANDING SEAM ROOF 0•_0' ry_p T M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL TOWNHOME A -WEST ELEVATION ❑ TOWNHOME A - EAST ELEVATION M9 METAL COPING ❑1/8' = 1'-0" 118 1 � r 1 PAINT COLORS P1 EXTRA WHITE - SW7006 ROOF BEARING ❑ ❑ O I ❑ ❑ � IIJ ❑ � O L1_I_l 30' - 5 114" P2 GRAY SCREEN - SW7071 I 1 I m P3 ROYCROFT PEWTER - SW2648 THIRD FLOOR h 21' P4 SMOKY BLUE - SW7604 mm e H_ ud m y m P5 LIGHT BRONZE - TBD I 11 ou o SECOND FL0008 ILLn❑ KEY PLAN o000 o000 o000 o00o I, o000 `° ,n II , , o ,I FIRST FLOOR 0' - 0" TOWNHOME A - SOUTH ELEVATION 1/8" = V-0' 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com D V a Ong ff 2 Q > O w�� W Z D o —O � U Z_ a_ '�^,LJ ZOLLJ O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: DATE DRAWN BY: CW, NS, RES CHECKED BY: JL EXTERIOR ELEVATIONS - TOWNHOME A W11:511 GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS s L FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN T VERTICAL RISE TO HAVE MINIMUM S'-6" HIGH LT - �r GUARDRAILS AS PER THE BUILDING CODE. —�� - 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR ���` r r r r ` L " MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT T •� T, - �, },- -� � � � -. ,-�- � -r _ PANEL /SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT RooFBEARINc �, SUBSTITUTION IS MADE. CONTACT ARCHITECT IF Elm_ 3B'-5� THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL - - - I TRANSITIONS BETWEEN WALL FINISHES. - - 0 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM THIRD FLOOR h — 22 F DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE �I ❑ ❑ = o z LO BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER "COMMERCIAL SHEATHING - TYVEK WRAP" TO 1 NE{ 1 1 o r1 m BE BASIS OF DESIGN SPECIFICATIONS. SECOND FLOOR 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 0171 tl � � _ °D 9. TERM FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR LDFLANGED EXHAUST LOUVER AT DUCT ,' PENETRATIONS AT WALLS (TYP). --` - - � - - = FIRST FLOOR ° ° 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. TOWNHOME B- NORTH E L E VAT I O N 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 1/8" = 1'-O"' 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. SYM. LEGEND ROOF BEARING I� 30' 551w _ ROOF BEARING 30'-51/ FFF a O DENOTES MATERIAL 0 0 DENOTES WINDOW NUMBER THIRD FLOOR h — 2r_a^ — THIRD FLOOR - FL (SEE SHEET AX.XX FOR O SCHEDULE) ❑ B e v o to . � � co V o0 �O MATERIALS o m co SECOND FLOOR h 19 _ LooR SECOND F_� 70'-8" M1 STONE VENEER, RUNNING BOND IF-M2 FIBER CEMENT LAP SIDING e0 e0 0 o M3 FIBER CEMENT BOARD AND BATTEN FIRST FLooR FIRsr FLooR M4 METAL STANDING SEAM ROOF 37' - 11 13/16" M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL TOWNHOME B - WEST ELEVATION TOWNHOME B - EAST ELEVATION OMETAL COPING , T „ TT PAINT COLORS - P1 EXTRA WHITE - SW7006 GRAY SCREEN - SW7071 ROOF BEARING h _ 30 -51/4' ' I HH THIRD_FLOOR 21 r P3 ROYCROFT PEWTER - SW2648 ❑ ❑ ❑ ❑ . e° �* = o � z P4 SMOKY BLUE - SW7604 o �n a�i P5 LIGHT BRONZE - TBD -roi m - -- SECOND FLOOR h o000 o00 o000 o00o i o000 ❑KEY PLAN 0 L 77.s; � 71: 17=7 PT FIRST FLOOR 0'-0" TOWNHOME B - SOUTH ELEVATION 1/8" = 1'-0' 220 E. Peterson Dx. Chazlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com G Q � O w W Z D o —O � U Z W O � a_ L.f� /r ZOLLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, INS, RES CHECKED BY: JL EXTERIOR ELEVATIONS - TOWNHOME B A2.05 GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR - ` MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL AN\ WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE I'' � TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL � TRANSITIONS BETWEEN WALL FINISHES. LOUNGE ROOM DORMER ROOF 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE LUBHOUSE ROOF BEARING BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE UBHOUSE LEASING ROOF _ BEARING I CORNERS FULL HEIGHT OF WALL (TYP.) ��ir-B^ 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. o I , 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS � AT ALL WALL SURFACES PRIOR TO EXTERIOR II FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS _ _ -- - FIRsrFLOOR h DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. CLUBHOUSE - NORTH ELEVATION 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. �SYM. LEGEND , I II �I I, Ir-T T I O DENOTES MATERIAL II II II - - I I I 1I III II I� �r � J J DENOTES WINDOW NUMBER i4 IT I I I I ' , I � (SEE SHEET AX.XX FOR O I _ III III III I ' ; I SCHEDULE) 1 >_ -- - I_ II III I- LOUNGE ROOM DORMER GOOF V I LOUNGE ROOM DORMER ROOF V III IIIL III III :III III II I-� I LTI1 1 ,- _.I II II II III�T O MATERIALS IIII _ CLUBHOUSE ROOF BEARING CLUBHOUSE LEASING ROOF Il I -1 - - CLUBHOUSE ROOF BEARING -.-.-. _. - CLUBHOUSE LEASING ROOF — BEARING h T ,- I, 'Y BEARING _h 11' _ 8, _ _ - 11' - E Y M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN LJLJI FIRsrF0_0 _� - _ _' _ FIRST M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL CLUBHOUSE - WEST ELEVATION CLUBHOUSE - EAST ELEVATION M9 METAL COPING O 1/8" = 1'-01, 1/8" = 1'-0" PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 LOUNGE ROOM DORMER R_ ooF P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 - - - CLUBHOUSE ROOF BEARING CLUBHOUSE LEASING ROOF '- BEARING r P5 LIGHT BRONZE - TBD I KEY PLAN FIRST FLOOR 0'-0" CLUBHOUSE - SOUTH ELEVATION 1/8" = 1'-0' 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com L.L Q nG O w W Z o —O � U Z LLII ^O L.L L.f� ZOLLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: DATE DRAWN BY: CW, NS, RES CHECKED BY: JL EXTERIOR ELEVATIONS - CLUBHOUSE A2.06 GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. r 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM L ~ . DESIGNS. T 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE — — — — — — — — — — — CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO N BE BASIS OF DESIGN SPECIFICATIONS. 0 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR co FINISH INSTALLATION. e 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS \ / DETAILS & MANU. RECOMMENDATIONS. FIRSTFLoo.R 10. PROVIDE PRE-FAB. FLASHING BOOTS OR o' o FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. POOLHOUSE - EAST E L E VAT I O N 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 1/8" = 1'-O" 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. �SYM. LEGEND ODENOTES MATERIAL c ODENOTES WINDOW NUMBER (SEE SHEET AX.XX FOR SCHEDULE) MATERIALS POOLHOUSE ROOF BEARING POOLHOUSE ROOF BEARING M1 VENEER RUNNING STONE U G BOND N o w o M2 FIBER CEMENT LAP SIDING ih 777FIRsrFLOOR_� M3 FIBER CEMENT BOARD AND BATTEN o FIRST FLo oOR M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL POOLHOUSE - NORTH ELEVATION POOLHOUSE - SOUTH N[2] M9 METAL COPING 1/6 = 1'-0' 1/8" = 1'-01, PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 aO P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD ❑ KEY PLAN / / FIRST FLOO- R / _. 0' POOLHOUSE - WEST ELEVATION❑ 1/8' = 1'_ 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com a_ D O W w z z D o —O � U z_ NW ^O L.L L.f� OLLI z O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: DATE DRAWN BY: CW, NS, RES CHECKED BY: JL EXTERIOR ELEVATIONS - POOLHOUSE A2.07 ROOF BEARIN_.._ G_ /�. 30' - 5 114" V THIRD FLOOR 2r-4" T SECOND FLOG. R h_ FIRST FLOO.__. R h. 0'-0" V BUILDING B (M) - NORTH ELEVATION 4 ROOF BEARING h 30'-5114" T THIRD FLOOR h 21' - 4" T SECOND FLOO._... FIRST FLOORT h 0'-0" BUILDING B (M) - WEST ELEVATION 3 _ BUILDING B (M) - EAST ELEVATION 2 1/8,, = 1'-0" GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. SYM. LEGEND ODENOTES MATERIAL ODENOTES WINDOW NUMBER (SEE SHEET AX.XX FOR SCHEDULE) O 1 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL M9 METAL COPING O I PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD KEY PLAN 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D O �Ir V I— Z CW G Q a_ > O w I- Z W D o —O � U Z W O a� L.f� _ /r ZOLLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, NS, RES CHECKED BY: JL BUILDING B (M) - SOUTH ELEVATION Li 1/8' — 1'-0' EXTERIOR ELEVATIONS - BUILDING B MIRRORED A2.08 ROOF BEARING h 3a-51/4" T THIRD FLO. OR. �. zr_4 V SECOND FLOOR d. 10' - 8" w FIRSTFLOOR h 0'_0" 7 BASEMENT LEV.. EL �. 70'_8" V BUILDING D (M) - WEST ELEVATION 3 MIHINININHIN ROOF BEARING $ 3a-51/4" T THIRD FLOO... R h — 21' - 4" Y SECOND FLOOR h 1a-8" FIRST FLOG_ R ,L a -a V BASEMENT LEVEL �... BUILDING D (M) - NORTH ELEVATION 1/8' — V-0' O zazz z zr-- =r r r r— _ _ _ _ _ z �S ����_�_�� -r r= ——rrrrrrrrr ---------------- � � z z z z -- —zzr�r r= ---- � z = r _Yir__ _ ====z z= —�= 3 rrrrrrrrrrrrrr_ QOON�O� —_—_---sssa I — - � I i ■ II i� -Iiii■unh■ if Ii1ii --n nmm I ii1— 1 1I - � ■■ ■■ ••!!6 IIInnllrn,l �_ �I- ..- _ROOF BEARING $L 3a Br 51/4" `I THIRD FL OR R. —21'-4" V SECOND FL00 Rom 1a-8" V. FIRST FLOOR a_0" Illll■■II=I!1=1511111=111III F011I■I GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. a ISYM. LEGEND ODENOTES MATERIAL ODENOTES WINDOW NUMBER (SEE SHEET AX.XX FOR SCHEDULE) O 1 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL BUILDING D (M) - EAST ELEVATION 2 O M9 METAL COPING BASEMENT LEVE.. L h. _10• _ g• V ROOF BEARING & 3a-5 THIRD FLO 21' - 4" YOR h _ SECOND FLOOR h 1 FIRSTFLOOR t, p1_0 q O PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD KEY PLAN 01 16N 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, NS, RES CHECKED BY: JL BUILDING D (M) - SOUTH ELEVATION❑ 1 /8" = V-0' EXTERIOR ELEVATIONS - BUILDING D MIRRORED CLINE GEN. NOTES 1. .:.... .. FROBUILDING IS M .. PROVIDE BUI G ADDRESS IN 6" HIGH LETTERS TO BE -. . BY FIRE MARSHALL. ADDRESS 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES NUMBERS TO BE ILLUMINATED. - WALKWAYS ELEVATED MORE THAN I VERTICAL RISE TO HAVE MINIMUM T-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. mm m m m3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION.CONTACT �Iw■ Ja-1--- -Z—ri--�iIIlwl■.■-I--_iSi-i--Za�'I— i—i_i_—_a`_T_--w_—ry—aa�`�_+w��i_—i-_—._iw—li_—ii—iiwiy—aI`I—I:— IZya�`-—�---r--.--Z--a�w-rrr���----itZrr__�—y�w• ARCHITECT il-rl• • DETAILS DUE l-- �yMINIMrrrrrrTO PRODUCT• _w __ G--i aia -Twain rw—%--� - ■ Iw-.. %i-�r�i---iiZ��iZ�Z�rra�a�-iii■-ia-ia�Ziia�Z�i�ia��--��■��a�=a�ia-ra�■1-�iriZli-a!+�_ PROVIDE aiy ■1w- i-iw iyiii iattyyarta�wZa->•■Mitt. Ii�wrZiYZiZi-'i�i^' iyrLT---■y--�IaVa�yZi°i-TRANSITIONS Z. rw--all-wrw--w�ili-=1.� r.�aZw- i i yi a�lyw a\ --y----+' -----yyzr=--1---w-- +---rrriZri.�rw.-.�i F - ='Z-�■�--Z—I---w—J---- y T--Ir--+—Z y-fir—T—-----+--�"ar+-- y y ------11---ME SIEMENS y---y--------z---y-----------y------•-------- a1��r_Zirrwriiii�iwY.rr�l-��-ylZ+wit-7�'I�riYrriZir-ZZZZir+-�.lZ+rrl�ar-rw-lei.° - -i■ w- wwala+ ■I� a- lii--ww-aV-w-aw�w--ai■-a�wa✓•-w-i-a- i-- a-� �iii�a�iiiaLiii.P.�s = - a■I Zwiii-1 wilily---lyiwiw-ywiii+r-�. ..---w-ly--•-yy--r ■lal.Iir■ �_i_iii_i_ii;iiiiiii-asiia�ilia�iii�ia� a�iiiiiia- �iiiiia�a■I yrrr. •.. • - •MOISTURE ,at_a✓•la-ii-�I-a�-wZ-a��ar Z--wZZ-a�-a�IZZZi a� iiii iii i liit•'ia�ii-- y r+iw-. Z—wr-a. �iwiyia�a■lyl+i- MMIa -- TI_.-.-.iii_ii_ii_i •� • -- w --��a iii -■. 1iw i�l-I- - yal- ��_. - -�-ii ww ii i i-i i i i i a`- ww■�1 Zw� -� �I - is - ■la' 3 iii i�i•aiiZaL�iri aiiit✓iii iiaLil a�- �I - CORNERS• a■-Zwla�-i la�iiila�iii�a�iiilarii ■f•ila�ii--a�ii: •I' �rrl�-rrrriZwr�-.�Z1-ri�-�e-r i - --- ` mow- . yl- I--i----y--------y---r�rzaee.= ZT—z� ,�yyYr.�ia���L7. -- -i i-IN -- i i i - i - i i--�� �° PROVIDE CONT.. • OVER yr= r==Yi==:�rlr���-y=Y�r i M�yS�Z+ ya - -- -------iii-- ----iiiw-- - ii-- iii--- -�.—=-rri—rrri— =—�-rHEATHING - TYVEK "COMMERCIAL WRAP" TO yi-----sZ� =--BE BASIS OF DESIGN SPECIFICATIONS. •"a+iiw-- --w -- yNr-- :.5'f■LT..Z� y-l=. SURFACES _a.:.wr--Z�,.�.CC�LL--%-C---� � _ a--_-■fir---�.�---,�--Iw-a_-_r .1.�.0�_ `a,-w BD...SYSTEM • • AT ALL WALL FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS 10. PROVIDE PRE-FAB. FLASHING BOOTS OR MEN NIEMEN AT DUCT MEN NIEMEN Nor—�—_-_IIMEN NIEMENII III IIIMEN NIEMEN__ —■— _1111�111_ NONEMEMO _IN _—_ - ■� _ aI 7 _ IIII���IIII — ■ a I� I� IJ ■ NN IIIIII-iillili�—=I1 I..i.i.i.— LEI 10 ■ ■■ PAPER BARRIER AND ONE LAYER BUILDING :WEATHE- IIi.I....::..::..::..... II SEALANT AT VERTICAL TRANSITIONS f�i� 1111111111uulllllrlll Hill ! ! 11111111111�111111111111111111111111111111�11 ! 1 _—on I BETWEEN WALL FINISHES. n-IiRD EL 0 21 zr-4 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT -a FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. SECOND FLOOR h 19-81, V FIRS-TFL. __OR h a_o. V BUILDING B - WEST ELEVATION - ENLARGED 2 ■iaraw■� NINE- l yy+ r i ���-- •aa �-��: yl6 .aa _ _ _.Jw_w_Z-yw_w_wa✓. __ _ r ___ aL-w.��■ir�..�__:����---iw--w �w-w--w ywwwwww■tg._---w----,_ --- .www - -■-- .Lrrwiwwlwww rr..�w—iw--- ■-w-waLwwY.Ly..--.Llw-w-L--�- . y-waL-wl ---:a✓•—w—a✓• wa-ww.—aJ--�w--ww—w�wwia�—�ww wwwwwwwwwwa�waLww�iia�.---wwi—aiT�iww�lr-—wwwwwww�w®I —=Zy---r--11—---y---1--------1y--°—il-----1y--1-1y--Zy---1y---1y----------r+1i--+1i--Zi,� -1---� rrrr-----_ -----1--- ------ — w------rr ---- - —1-- rrr—y=- SIEMENS —r :y-w-aL--a-w!i -iy-Zii-ia�i----Za1■yw�-wwlwr■- wwyw-wwww i--ila■ -- a- wlwww- -w ---�-�---�---w--+1�-+°-y---+�wwrW�Z,--y---�wrr+---�c+�i-ww�ir��w ----:ala---a`w-a--w wai■iww iwilii - w-■al■----w---■lalaw--al■w waLwww.�wiwaLwlwwww w-w-alawwwaVMil ---yii-�-w-----'-I�-w--1-y---wy--1-y---yww----`---1----------�_li-■ _wl�--wy---y-- ■ wwMINIMw w ■yww' w-I -■ w y II -I y �Z—��r---y--� --z-- —z i—_—,.yi--- i-------- i+r—yr--+r--s----_yi—r—r S _r i iyr -w.- -ate- a� I +wwww--w1a�-wila�-- wwla■ w I� -w www ---I w--I ■a. -ii - - --ate -ate ■. -} - ■ www�yww-�i■r w�yywwwwww+www��wwwwyww�-iawww �,y �1■aia1 wr yw wyyyww�rllwwwr.�� --wwww- ly wwJaywwr y�- }ZaL1�+�ww�wwwwa`www wwwwwwwa`ww--a-�r�waT�Tww�.w�w�wyawaLwwwwwwywwls �w-a��wi �ywwwyaTies www---wl--�- --->.,y-w-yy---w-'y----yi.--==-Lrr= w--y---- ---w i-wwwy-L ZZyia�ry= ==-i-------w--+I-y-L==-■ar-r-y---yww- �w--y_--r '+w y----- "ii-' yi--'ii-- -�yl iy—i-- �----�—r�1--+ Y-il - r>:,i--ai�y�rwi---w `Ti' ■wwi T� -cyw� rlMINI 0 11i■TwT�wTwi==r-�-==- =--� = y--==y=®! Ti-s�� �T��wilY4G ��`■� .�.�yira �yi- - �--1-yiiii'�--1-yi-iy---yii-+-----iiwy-w-�-wl-I�w-w■ - wi--I - F� �� -w w- wwwww-■ MINIM ]MINI w-■��wwi wia�wwww■- -ea- awl wwy- _ia-i.%-i-yala-rwT_■Tii■---ia-il-Iw-ii-ww_: wwwwwwwl -._-i-wl�i3�G--wwwia-i--i-wwwwwlw� arm IiL-�--'� Fwa�-ilwwia--i-, w Zl�or la■ ww w Iww ■a�.�s�w wwww wE.... ®--ia�ra�. �rli 1=01 ---at www--■--.c -I■r www -i- -MIMI o ■--w r y i �wr a= wwl Iwyi■rw■ iilaa wr-lawi- -haw-ia�w p '-.A■I■■w -wY IV =w,w9�_�_w�_■�____ ! --- `sr :-1a���Mir wwrw--- _icwwlw�ww- •�r�rrl����ilnJlr iw�y-.--wy-w-wyaal-- -" -r--a✓•---a✓• ' -- 1 lia✓•y-.-w y = y� -- -.s- www ---e Iwyw.-wyw�wy1�_lw� MENNEN 4 III MENNEN I I 1 —_I__IIIIIIJ� —■�1I --DI III NJ— -IIIIII - - I _ 1 — MENEM O— - I __ -- I - I — IaI 1 IaI 'III 0 LNJ 11�� M-�� 1...�.� ,.�...,.�.�.�.�.�I r:, O IJ a 11111111= ����ti=������ �� ■ ICI 1�1 O — - Z 11111111111111II1111111111 �11111111111111111111111111111111111111111111 I — _ I � 11111111111111 n11111r11IIIMIN 11111unlinMINIM111111111111111111111 _ 1 - - - I � ...�.LL-•I I 1 r �— — "... ..L,..-.LL.LL..LL..LLIII •'•"" MINI L.LLI - 1 •. ..• — _ I �' '1_ �— —'_ 1 MINI- - I � 1 u - I w-a ww LXIII _ 1 - -._ I1_ I NONE —— ' _1 -I—III III— — 1—III 11 --III III — ■ =IIII III - - _ I — � II I Ii11171111111111111111111111111i11111111111111111111111 1 -- — ' I II III II lllllll IIIIII IIIIII Illllil11111111111111111111 _ 1 - -111111111111111111111111111111111111111111111111111111111111 1 -- IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII _1 - - _ IIIIIIIIIIIIIIIIIIIIIIIIIIIIilllllllllllllllllllllllllllllll -1 -- IIIi111111111111111111111111111111111111111111111111111� _ 1 - -111111111111111111�11111111111111111111111111111111111111 - � �— — : I�III1111I11111!1111111111111111111111111111111111111111 = I = NIEMEN -..ItIO..••.ItItI•.•ItI•I•••••••I••••I•••IIII -- 6.Ip•..•�.!..•R..•R..•••.•••.•••.••I —._ I— 1• �— _I - - _ lT�r_ r� '_ 1 — - _ -! _1 - - _ -=Evi — _1 — __ Fill] III=_ _ 1 11111 III III I — — _lllllll_ — _ 1_ -- I — _1 _ — _ 1 _ �— I iwl _ 1 _ — _ IaI IaI I 1 1�1 ICI —_—_ ICI � I —_1• I —_ 'I 1 _ —_� I-.Z"uuliu n-n min n■-nml.nml.nml _ 1 __ __I10 111�1111 �_ -IIIIIIIIIIIIIIIi1111111111111111111111111111111111111111_ _-1---__---- -__ ____ ___________ n1111111u1111111nuunnnn11nn11111n11111u1111 - • __ _ __ .-11111111111111 II��*- < _� _e:�IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII _�_� ----�I �-�■°-1111NIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIILIIIi11�11�°-I'� ��---�-I =' �S`�. y ■ate-r--;ate--;a��-;�i-;--ice, _.___ - : 5-�aG--;ate--;awl-;ate -�r�-��--.� i■i _.___ ___ ____.____._ _.____.__._ �-�a--�-�r�-�r�-�i%=.� •.' I I � 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. SYM. LEGEND ODENOTES MATERIAL ODENOTES WINDOW NUMBER (SEE SHEET AX.XX FOR SCHEDULE) O 1 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METALCANOPY O M8 FIBER CEMENT PANEL M9 METAL COPING O I PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD KEY PLAN 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D O Ir Lu CG Q a_ > O w I- Z W D o —O �0 U Z W O LL _j a_ ZO _ MW O W VJ PROJECT: 221074 DATE: 09.26.2022 REVISIONS: DATE DRAWN BY: CW, NS, RES CHECKED BY: JL BUILDING B -EAST ELEVATION - ENLARGED 1 ENLARGED EXTERIOR ELEVATIONS - BUILDING B III III =MM MmmMM=m •No III II 1 !!l W....r!ip CLINE 1 W ROOF BEARING h 30' _ THIRD FLOOR 2 SECOND FLOOR 1 FIRST FLOOR h 0'-0 GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM T-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n BASEMENT LEVEL It W z �SYM. LEGEND 3 0 w N W K XX DENOTES MATERIAL a A x 7 DENOTES WINDOW NUMBER z z BUILDING C - WEST ELEVATION - ENLARGEDI* O SCEHESHEET AX.XX DULE)FOR o ww 3 6 0 G Q MATERIALS 3 O ❑ J a uj �- M1 STONE VENEER, RUNNING BOND z M2 M8 M8 M8 M6 M2 M5 M1 M8 'z W M2 FIBER CEMENT LAP SIDING o Q O P1 P4 P3 P1 P2 P4 P1 w M3 FIBER CEMENT BOARD AND BATTEN O U a z W J M4 METAL STANDING SEAM ROOF 0 O F w M5 ARCHITECTURAL SHINGLE ROOF a Lr1 L O z - M6 PREFABRICATED METAL RAILING w z ui Li m M7 PREFABRICATED METALCANOPY � � J w �/� v� Q M8 FIBER CEMENT PANEL 0 M9 METAL COPING I LL i z ROOF BEARINGNG & w 30' - 5 T mr,. SEE MINI 8 ky THIRD FLOOR h 21 - 4" T SECOND FLOOR 10'_8„ $ FIRST FLOOR h 0,_01 I ❑ I PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD KEY PLAN PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, NS, RES CHECKED BY: JL BUILDING C -EAST ELEVATION - ENLARGED 1 ENLARGED EXTERIOR ELEVATIONS - BUILDING C MOM E- CLINE )OF BEARING h 30'114 FHIRD FLOOR $ 2 JOND FLOOR ,$ i FIRST FLOOR -MEN T LEVEL h 40'-8" BUILDING D - WEST ELEVATION - ENLARGED 2 GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM T-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. SYM. LEGEND ODENOTES MATERIAL ODENOTES WINDOW NUMBER (SEE SHEET AX.XX FOR SCHEDULE) O 1 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL M9 METAL COPING O I PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD KEY PLAN 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D O Ir I— Z CW G Q a_ > O w I- Z W D o —O � U Z W ^O ry L.L ZOLLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, NS, RES CHECKED BY: JL ENLARGED EXTERIOR ELEVATIONS - BUILDING D BUILDING D - EAST ELEVATION - ENLARGED 1 A2.16 M5) C M2 ) ( M3) C M4 ) ( M2) ( M1 I.II" I r.I..n I. I. I. I.. f.:1.. i, i] T.. FEW I Il:J:a 1.. 1 I.I Z I: r..1: 3:: 1 n If:e 00 I J I ::.: 1.. C I . I ::: 1. : 'I :....0 e'. DO ao O ROOF BEARING h W - 5 114" `I THIRD FLD012 h 21'-44• TOWNHOME A - NORTH ELEVATION - ENLARGED F2 3/16" = V-0' GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. SYM. LEGEND ODENOTES MATERIAL ODENOTES WINDOW NUMBER (SEE SHEET AX.XX FOR SCHEDULE) O 1 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL M9 METAL COPING O I PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD KEY PLAN 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D O Ir I— Z Lu G Q a_ > O w I- Z W D o —O �0 U Z W O LL _j a_ ZOO LLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, NS, RES CHECKED BY: JL TOWNHOME A - SOUTH ELEVATION - ENLARGED ENLARGED EXTERIOR ELEVATIONS - TOWNHOME A TOWNHOME A - WEST ELEVATION - ENLARGED 2 GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM T-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. SYM. LEGEND ODENOTES MATERIAL ODENOTES WINDOW NUMBER (SEE SHEET AX.XX FOR SCHEDULE) O 1 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL M9 METAL COPING O I PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD KEY PLAN 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D O Ir I— Z CW G Q a_ > O w I- Z W D o —O �0 U Z W O LL _j a_ ZOO LLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, NS, RES CHECKED BY: JL TOWNHOME A - EAST ELEVATION - ENLARGED 1 ENLARGED EXTERIOR ELEVATIONS - TOWNHOME A A2.18 M5 rr■lmU1.[■1169a:1 iON ILE LEN N M3 M4) ( M2 M1 1r■D0111.[■D69�:1 ■ by z �r� yr. yr WE. FEE i �iy� R$E��_ _ ilL4aiiRlQt�i�! ■ ■ i ■ a ���lEID, '� i �IEIM III 1:11:1 ie tr■pp/lpL■D&Lm. ■ ■ TOWNHOUSE B ROOF BEARING 0� THIRD FLOOR 2I'-Y SECOND FLOOR h FIRST FL_ OOR h D• - 0" V TOWNHOME B - NORTH ELEVATION - ENLARGED 3/16" = V-0' TnWNHCH ICF R Tr)%A/NH(ll ICF R TCHA/NHni ICF R TOWNH(N ICF R ROOF BEARING Ab 30'-57/4' T THIRD FLOOR R h. SECOND FLOOR h GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. a __]ISYM. LEGEND ODENOTES MATERIAL ODENOTES WINDOW NUMBER (SEE SHEET AX.XX FOR SCHEDULE) O 1 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL M9 METAL COPING PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD KEY PLAN 01 16 N 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com JG G� PROJECT: 221074 DATE: 09.26.2022 REVISIONS: DATE DRAWN BY: CW, NS, RES CHECKED BY: JL TOWNHOME B - SOUTH ELEVATION - ENLARGED II ENLARGED EXTERIOR ELEVATIONS - TOWNHOME B A2.19 TOWNHOME B - WEST ELEVATION - ENLARGED 2 GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM T-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. SYM. LEGEND ODENOTES MATERIAL ODENOTES WINDOW NUMBER (SEE SHEET AX.XX FOR SCHEDULE) O 1 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL M9 METAL COPING O I PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD KEY PLAN 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D O Ir I— Z CW G Q a_ > O w I- Z W D o —O �0 U Z W O LL _j a_ ZOO LLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, NS, RES CHECKED BY: JL TOWNHOME B - EAST ELEVATION - ENLARGED 1 ENLARGED EXTERIOR ELEVATIONS - TOWNHOME B A2.20 N DORMER ROOF E ROOF BEARING m_T IE LEASING ROOF BEARING 11'-6" T FIRST FLOOR h 0•-0" V CLUBHOUSE - NORTH ELEVATION - ENLARGED❑ 3/16' = V-0' LOUNGE ROOM DORMER ROOF 18'-0" V CLUBHOUSE ROOF BEARING h it -n-n- CLUBHOUSE LEASING ROOF BEARING it BEARING FIRST FLOOR h 0' OR V GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. SYM. LEGEND ODENOTES MATERIAL ODENOTES WINDOW NUMBER (SEE SHEET AX.XX FOR SCHEDULE) O 1 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL M9 METAL COPING O I PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD KEY PLAN 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D O tr G Q a_ > O w I- W Z D o —O � U Z W ^O L.L ry ZOLLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, NS, RES CHECKED BY: JL CLUBHOUSE - SOUTH ELEVATION - ENLARGED 3/16" = 1'-0' ENLARGED EXTERIOR ELEVATIONS - CLUBHOUSE A2.21 GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL M3 M5 M5 WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF P'I P4 P4 THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS LT-LT-1 DETAILS & MANU. RECOMMENDATIONS. I 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER LOUNGE ROOM DORMER ROOF �, WEATHER BARRIER AND ONE LAYER BUILDING 78 PAPER - - - - - 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. CLUBHOUSE ROOF BEARING 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE CLUBHOUSE LEASING ROOF e� ELIMINATED. m-e• - 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL _ NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. ILL[ I i FIRST FLOOR h �SYM. LEGEND ODENOTES MATERIAL - WEST ELEVATION - ENLARGED OR NUMBER DENOTECLUBHOUSE 2 SCHEDULE) SCHEDULE) 0 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M2 M5 M1 M7 PREFABRICATED METAL CANOPY P1 P4 M8 FIBER CEMENT PANEL M9 METAL COPING _ LOUNGE ROOM DORMER ROOF „ _ _ 7 PAINT COLORS P1 EXTRA WHITE - SW7006 - - CLUBHOUSE ROOF BEARING h CLUBHOUSE LEASING ROOF BEARING P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 - P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD FIRST FLOOR T 0'_0• 11 KEY PLAN CLUBHOUSE - EAST ELEVATION - ENLARGED 3/16" = 1'-0' 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D Illy G Q a_ > O w I- W Z D o —O � U Z W O � a_ L.f� ZOLLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: DATE DRAWN BY: CW, INS, RES CHECKED BY: JL ENLARGED EXTERIOR ELEVATIONS - CLUBHOUSE A2.22 GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN M8 M5 M2 M4 M8 M1 VERTICAL RISE TO HAVE MINIMUM 3'-6"HIGH GUARDRAILS AS PER THE BUILDING CODE. P1 P4 P1 P5 P3 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS -_ - - -- DETAILS & MANU. RECOMMENDATIONS. - -- p- - - - 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). `'=�� T�r 11. INSTALL STONE VENEER OVER ONE LAYER -- - - - - WEATHER BARRIER AND ONE LAYER BUILDING - - -- - - - - -- - -- __ PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT I EXCEED30%. FIRST FLOG.._.. R. h 0'-0" Y �SYM. LEGEND ODENOTES MATERIAL POOLHOUSE - WEST ELEVATION - ENLARGED O (SEEOSHET'AXOX OR NUMBER 2 SCHEDULE) 0 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M1 M8 M8 M5 M4 M2 M8 M7 PREFABRICATED METAL CANOPY P1 P3 P4 P5 P1 P1 M8 FIBER CEMENT PANEL M9 METAL COPING - -„ , 11 - PAINT COLORS P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD ❑ KEY PLAN - FIRST FLOOR 0'-0" POOLHOUSE - EAST ELEVATION - ENLARGED 3/16" = 1'-0' 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D ry G Q a_ > O w I- W Z D o —O � U Z W O � a_ L.f� ZOO LLI O m PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, INS, RES CHECKED BY: JL ENLARGED EXTERIOR ELEVATIONS - POOLHOUSE A2.23 GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM M5 M8 M1 M2 DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE P4 P1 P3 BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR - FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER - - _ ._ _ _- _ 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT - -I I I -I I i I I I FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. _ _ POOLHOUSE ROOF BEARING 13,-a" T 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT FIZI EXCEED30%. FIRSTFLOO. R h __ 0' - 0' Y �SYM. LEGEND ODENOTES MATERIAL POOLHOUSE - SOUTH ELEVATION - ENLARGED O (SEEOSHET'AXOX OR NUMBER [2] SCHEDULE) 3/16" 0 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL M9 METAL COPING M1 M5 M8 P4 P1 IILL PAINT COLORS P1 EXTRA WHITE - SW7006 _ POOLHOUSE ROOF BEARING GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD 0 , FIRST FLOOR / KEY PLAN 0' - 0" POOLHOUSE - NORTH ELEVATION - ENLARGED 3/16" = V-0' 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D Illy G Q a_ > O w >: I- W Z D o —O U Z W O � a_ L.f� ZOO LLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, INS, RES CHECKED BY: JL ENLARGED EXTERIOR ELEVATIONS - POOLHOUSE A2.24 CLINE r M2 M8 P1 P4 P1 I■IIIm M8 P3 R M6 M2 a M1 ) C M5 M8 P1 171 Fill] OOF BEARING h 30'-5iw T THIRD FLOOR O....R h 21'V -COND FLOOR FIRSTFLOOR 0-0., T BUILDING B (M) - WEST ELEVATION - ENLARGED L2j 3/16' ROOF BEARING h 30'-51/4' T THIRD FLOOR h 21' - 4" I SECOND FLOOR R h 10'-8' Y FIRST FLOO. R h 0'-0" Y GEN. NOTES 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING PAPER 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 14. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED30%. SYM. LEGEND ODENOTES MATERIAL ODENOTES WINDOW NUMBER (SEE SHEET AX.XX FOR SCHEDULE) ❑ 1 MATERIALS M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING M3 FIBER CEMENT BOARD AND BATTEN M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL M9 METAL COPING ❑ I PAINT COLORS P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 P5 LIGHT BRONZE - TBD KEY PLAN 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D O ry I- Z Lu G Q a_ > O w I- Z W D o —O � U Z W ^O ry L.L ZOLLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, NS, RES CHECKED BY: JL BUILDING B (M) - EAST ELEVATION - ENLARGED 1 3/16" = 1'-0' ENLARGED EXTERIOR ELEVATIONS - BUILDING B MIRRORED A2.26 III III � NEI! 9 ,NN CLINE GEN. NOTES M2 M8 M8 M2 M8 M1 M6 M8 1. ADDRESSING SIGNAGE TO BE LOCATED ON THE SIDE OF THE BUILDING FROM WHERE THE P1 P4 P3 P2 P1 P1 BUILDING IS ADDRESSED (ONE SIDE ONLY). PROVIDE BUILDING ADDRESS IN 6" HIGH LETTERS TO BE APPROVED BY FIRE MARSHALL. ADDRESS NUMBERS TO BE ILLUMINATED. 2. SEE WALL SECTIONS & ENLARGED ELEVATIONS FOR GUARDRAIL HEIGHTS. ALL BALCONIES OR _ WALKWAYS ELEVATED MORE THAN 30" IN VERTICAL RISE TO HAVE MINIMUM 3'-6" HIGH -- —I KKK GUARDRAILS AS PER THE BUILDING CODE. 3. REFER TO SPECIFICATIONS FOR ALL EXTERIOR MATERIALS. THE WALL SECTIONS AND DETAILS SHOWN IN THIS SET REFLECT FIBER CEMENT PANEL / SIDING WITH 5/4 TRIM. ALL MATERIAL — WIDTHS TO REMAIN SAME SIZE IF ANY PRODUCT SUBSTITUTION IS MADE. CONTACT ARCHITECT IF — — THERE ARE ANY DISCREPANCIES IN DETAILS DUE TO PRODUCT SUBSTITUTIONS. ROOF BEARING h 30'-5 V4• 4. PROVIDE METAL FLASHING AT HORIZONTAL TRANSITIONS BETWEEN WALL FINISHES. ❑ ❑ — 5. SEE ROOF PLAN FOR OVERHANG DIAGRAM DESIGNS. D El [u] 6. APPLY AN ADDITIONAL 12" LAYER OF MOISTURE BARRIER (6" EACH SIDE) AT INSIDE/OUTSIDE CORNERS FULL HEIGHT OF WALL (TYP.) — 7. PROVIDE CONT. BUILDING WRAP OVER SHEATHING - TYVEK "COMMERCIAL WRAP" TO BE BASIS OF DESIGN SPECIFICATIONS. THIRD FLOOa__� 27 ° 8. INSTALL BUILDING WRAP SYSTEM CONTINUOUS AT ALL WALL SURFACES PRIOR TO EXTERIOR FINISH INSTALLATION. I Ji — El L ❑ 9. TERM./FLASH BUILDING WRAP AT PENETRATIONS DETAILS & MANU. RECOMMENDATIONS. 10. PROVIDE PRE-FAB. FLASHING BOOTS OR FLANGED EXHAUST LOUVER AT DUCT PENETRATIONS AT WALLS (TYP). — 11. INSTALL STONE VENEER OVER ONE LAYER WEATHER BARRIER AND ONE LAYER BUILDING — PAPER SECOND F70' 8"Lo 8 —� 12. PROVIDE SEALANT AT VERTICAL TRANSITIONS BETWEEN WALL FINISHES. ❑ ❑ 13. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL 14. u NOT DROP BELOW 40 /o. _ 15. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED 30%. FIRST FLOOR. / 0' - 0" V O O ❑ O O i BASEMENT LEVEL. / —10-8" V �SYM. LEGEND ODENOTES MATERIAL BUILDING D (M) - WEST ELEVATION - ENLARGED O (SEEOSHEOR NUMBER 2 SCHEDULE)T'AXOX 3/16" = 1'-0" M5 M2 M8 M6 M2 M1 M8 M8 M8 M6 O MATERIALS P4 P1 P3 P2 P4 P1 P1 M1 STONE VENEER, RUNNING BOND M2 FIBER CEMENT LAP SIDING FIBER CEMENT BOARD AND BATTEN --- - - M4 METAL STANDING SEAM ROOF M5 ARCHITECTURAL SHINGLE ROOF M6 PREFABRICATED METAL RAILING M7 PREFABRICATED METAL CANOPY M8 FIBER CEMENT PANEL ❑ ❑ _ ROOF BEARIN. G h 30'-51/4" V M9 METAL COPING Li ow — THIRD FLOOR h 21 _ 4...T TIE PAINT COLORS SECOND FLOOR 10,_8 Y ■ � O � O ■ O ® P1 EXTRA WHITE - SW7006 P2 GRAY SCREEN - SW7071 a P3 ROYCROFT PEWTER - SW2648 P4 SMOKY BLUE - SW7604 - FIRSTFLOOR -h. 0'-0. Y P5 LIGHT BRONZE - TBD O O ■ O O J KEY PLAN - BASEMENT LEVE..L _19_81 Y BUILDING D (M) - EAST ELEVATION - ENLARGED❑ 3/16" = 1'-0' 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com n D ry G Q O �- W W Z D o —O � U Z W 00. L.L _j ZOO LLI O m v! PROJECT: 221074 DATE: 09.26.2022 REVISIONS: I DATE DRAWN BY: CW, NS, RES CHECKED BY: JL ENLARGED EXTERIOR ELEVATIONS - BUILDING D MIRRORED A2.28 AMENITY DOOR SCHEDULE DOOR # DOOR INFORMATION FRAME INFORMATION FIRE RATING HARDWARE SET COMMEN ZS HEIGHT WIDTH THICKNESS DOOR TYPE DOOR MATERIAL FRAME TYPE FRAME MATERIAL FRAME DETAILS HEAD DETAIL JAMB DETAIL SILL DETAIL 1778 7' - 0" 3' - 0" 13/4" F HM 01 HM 2055 8.-0.. 2'- 6" 13/4" F HM 01 HM 2077 8' - 0" 2'- 6" 13/4" F HM 01 HM 2080 8' - 0" 2'-6" 13/4" F HM 01 HM 2081 8' - 0" 2'-6" 13/4" F HM 01 HIM 2082 8' - 0" 2'-6" 13/4" F HM 01 HM 3460 8' - 0" 3' - 0" 13/4" F HM 01 HM 4611 7' - 0" 3' - 0" 13/4" F HM 01 HIM 4613 7'-0" 3' - 0" 13/4" F HM 01 HM - 4618 7'- 0" 3'- 0" 13/4" F H M 01 HM - 6864 8' - 0" 3'- 0" 13/4" F HM 01 HM - 6867 7'- 0" 3' - 0" 13/4" F HM 01 HM - 6868 8' - 0" 2'- 6" 13/4" F HM 01 HM 6870 7'- 0" 3' - 0" 13/4" F HM 01 HM 6871 8' - 0" 2'-6" 13/4" F HM 01 HM 6872 8' - 0" 2'-6" 13/4" F HM 01 HM 6873 8' - 0" 2' - 6" 13/4" F HM 01 HM A105 8'-0" 3'-0" 13/4" F HM 01 HM - A115 8'-0" 3'-0" 13/4" F HM 01 HM - A116 8' - 0" 3'- 0" 13/4" F I HM 01 HM A117 8' - 0" 3' - 0" 13/4" G I unn lni unn - - A118 8' - 0" 3' - 0" 13/4" A119 8.-0.. 3'- 0" 13/4" /-REVIEW COMMON DOOR SCHEDULE DOOR # DOOR INFORMATION FRAME INFORMATION FIRE RATING HARDWARE SET COMMENTS EIGHT WIDTH THICKNESS DOOR TYPE DOOR MATERIAL FRAME TYPE FRAME MATERIAL 7'-0" 6'-0" 13/4" 2F HM 01 HM A123 8'-0" 6'-0" 13/4" 2F HM 01 HM CO3 7'-0" 13/4" FFG WD 03 WD LAKEHOUSE SCREEN DOOR C04 13/4" FFG AL 01 AL STOREFRONT C05 7' - 0" 3'- 0" 13/4" F HM 01 HM U 7'-0" 3'-0" 13/4" F HM 01 HM APARTMENT STORAGE DOOR 110 8'- 0" 9'- 0" 13/4" 1 OH2 I HM 102 1 HM I IUHW-7 I GARAGE DOORS - CARRIAGE HOUSE I UNIT DOOR SCHEDULE DOOR# DOOR INFORMATION FRAME INFORMATION FIRERATING HARDWARE SET COMMENTS HEIGHT WIDTH THICKNESS DOORTYPE DOORMATERIAL FRAMETYPE FRAMEMATERIAL U01 7' -0" 3' - 0" 13/4" 1P WD 03 MSJ* 20 MIN. UHW-1 UNIT ENTRY (SINGLE) UO2 7'-0" 3'-0" 13/4" 1P WD 01 WD 20MIN. UHW-1 UNIT ENTRY DOOR U05 7' - 0" 2'- 10" 13/4" 1P WD 03 WD 9 CLOSET (SINGLE - PASSAGE) U06 7'-0" 2--10" 13/4" 1P WD 03 WD 10 BDRM/BATH (SINGLE - PRIVACY) U07 6'- 8" 2--10" 13/4" 2P WD 03 WD 4 BDRM/BATH (SINGLE - PRIVACY) U14 6'- 8" 1' - 6" 13/4" ZP WD 03 WD 3 CLOSET (SINGLE - PASSAGE) U15 6'-8" 2'- 10" 13/4" 2P WD 03 WD 3 CLOSET (SINGLE - PASSAGE) U16 7'-0" 2'-4" 13/4" 1P WD 03 WD 9 CLOSET (SINGLE) U17 6'-8" 4'-0" 13/4" 2P1P WD 03 WD 18 CLOSET DOUBLE U18 6'-8" 5'-0" 13/4" 2P1P WD 03 WD 18 CLOSET DOUBLE U19 6'-8" 5'-4" 13/4" 2P1P WD 03 WD - 18 CLOSET DOUBLE U34 8' - 0" 3'- 0" 13/4" FG-T - -- - BALCONY (SINGLE) W/ TRANSOM U44 6' - 8" 2' -10" 13/4" 2P WD 03 WD 5 WH/AH (SINGLE - LOCK) U58 7'-0" 3'-0" 13/4" F HM 01 HM - APARTMENT STORAGE DOOR U110 8'-0" 9.-0.. 13/4" OH2 HM 02 HM 7 GARAGE DOORS - CARRIAGE HOUSE U111 7'- 0" 9.-0.. OH1 GARAGE DOOR - CRAFTSMAN U116 8'-0" 7'-0" 1 13/4" 1 1 1 SLIDING BALCONY DOOR 6-8 H SET #1 SET #2 SET #3 SET #4 6 Hinge 3 Spring Hinge 3 Hinge 6 Hinges 2 Panic Hardware 1 Lockset 1 Lockset 2 Flush Bolt 2 PA Closer 1 Cylinder Core 1 Cylinder Core 1 Lockset 2 Kick Plate 1 Wall Bumper 1 Gasketing 1 Cylinder Core 1 Gasketing 1 Gasketing 1 DeadBolt 1 PA/Stop Closer 1 Astragal Set 1 Overhead Door Stop 1 Brush Sweep 1 Astragal Set 1 Neoprene Gasketing 1 Saddle Threshold SET #5 SET #6 SET #7 SET #8 3 Hinge 3 Hinge 6 Hinge 3 Hinge 1 Panic Hardware 1 Panic Hardware 2 Lockset 1 Lockset 1 Kick Plate 1 Kick Plate 2 DeadBolt 1 DeadBolt 1 Gasketing 1 Gasketing 2 Kick Plate 1 Kick Plate 1 Wall Bumper 2 Wall Bumper 1 Wall Bumper 1 Coordinator 1 Astragal Set SET #9 SET #10 SET #11 SET #12 3 Hinge 3 Hinge 1 Sliding Door Track 6 Hinge 1 Passage Set 1 Privacy Set 2 Door Stops 2 Gasketing 1 Wall Bumper 1 Wall Bumper 1 Door Guides 1 Astragal Set SET #13 SET #14 3 Hinge 3 Hinge 1 Lock Set 1 Fire Exit Device 1 Cylinder Core 2 PA Closer 1 Wall Bumper 1 Gasketing 1 Lockset or Card Access SET #17 1 Cylinder core 6 Hinge SET #18 2 Panic Hardware 6 Hinge 2 PA Closer 2 Dummy Levers 2 Kick Plate 2 Wall Bumpers 1 Gasketing 2 Ball Catches 1 Astragal Set 1 Coordinator 1 Saddle Threshold 2 Brush Sweeps 1 Lockset SET #15 1 Track 1 Pocket Door 1 Lock Set SET #16 2 Track 2 Pocket Door Pasage Set NOTES: 1. DOOR MANUFACTURER TO PRECUT DOOR TO ACCOMODATE ELECTRIC STRIKE AND ELECTRIC MORTISE. 2.SEE SCHEDULE FOR ADDITIONAL SECURITY REQUIREMENTS. STAIRWAY DOORS TO COMPLY WITH 403.5.3 IF LOCKED FOR SECURITY. 3. DOORS ENCLOSING FIRE SERVICE ACCESS ELEVATOR LOBBY SHALL ALSO COMPLY WITH UL 1784 TEST CONDUCTED WITHOUT ARTIFICIAL BOTTOM SEAL. 4. FIRE DOOR ASSEMBLIES SHALL MEET SMOKE AND DRAFT CONTROL REQUIREMENTS PER 2017 FLBC SECTION 715. FIRE DOORS SHALL ALSO MEET GLAZING SIZE LIMITATIONS PER NFPA 80 AND TESTING REQUIREMENTS OF NFPA 252. DOOR NOTES: 1. SEE FLOOR PLANS FOR SWING DIRECTION 2. SEE ENLARGED PLANS FOR DOOR TAGS 3. SEE LIFE SAFETY PLANS AND ID DRAWINGS FOR DOORS AT CLUB AND LEASING 4. ALL DOOR CLOSERS AND SPRING HINGES AT RATED DOORS MUST BE NFPA 80 APPROVED 5. ALL PASSAGE DOORS AT TYPE'B' UNITS MUST BE MIN. 2'-10" WIDE. ALL PASSAGE DOORS AT TYPE W UNITS AND COMMON AREAS MUST BE T-0" WIDE. 6. ALL PASSAGE DOORS AT COMMON AREAS MUST BE T-0" WIDE. 7. ALL INTERIOR UNIT PASSAGE DOORS MUST BE 2'10" WIDE. 8. PROVIDE TEMPERED GALSS IN ALL DOORS AS REQUIRED BY THE STATE BUILDING CODE. T = TEMPERED GLASS. 9. EXTERIOR DOOR U VALUE AND SOLAR HEAT GAIN COEFFICIENT TO COMPLY WITH THE NC BUILDING CODE. 10. ALL DOOR HARDWARE AT TYPE W UNITS AND COMMON AREAS TO COMPLY WITH ICC At 17.1-2009 SECTION 404.2.6. 11. PROVIDE DOOR STOP AT ENTRY DOOR AND ANY OTHER DOOR THAT SWINGS INTO A WALL OR CABINET. 12. G.C.TO COORDINATE ALL SECURITY REQUIREMENTS BY OWNER WITH DOOR FRAMES. 13. G.C. TO COORDINATE FRAME SIZE WITH DOOR MANUFACTURER REQUIREMENTS. 14. ALL GLASS IN DOORS AND SIDELIGHTS TO BE TEMPERED. 15. IN ALL UNITS PROVIDE LOCKSETS @ BEDROOM & BATHROOM DOORS 16. PROVIDE PANIC HARDWARE ASSEMBLY AT ALL ELECTRICAL ROOM DOORS. *METAL SPLIT JAMB - DOOR FRAME TO MEET REQUIRED FIRE RATING FOR DOOR TEMPERED GLASS NOTES: GLAZING IN INDIVIDUAL FIXED OR OPERABLE WINDOWS WITHIN A 2'-0" RADIUS OF A DOOR (OPEN OR CLOSED POSITION) THAT ARE IN THE SAME WALL SHALL HAVE TEMPERED GLAZING UP TO A HEIGHT OF 5'-0" ABOVE FINISHED FLOOR. T.G = TEMPERED GLASS LOCATION o 'TZ r'T.G. WIDTH I WIDTH ( WIDTH WIDTH GLAZING SCHEDULE: ti - w _ _ _ To TEMPERED GLASS _ w W uw w x x x x J ui J J J W W W � CO TYPE 01 TYPE 02 TYPE 03 TYPE 04 HOLLOW METAL HOLLOW METAL WOOD / ALUMINUM FRAME FRAME FRAME METAL SPLIT FRAME E ELEVATIONS SCHEDULED DOOR TYPE ELEVATIONS F COMMERICAL / AMENITY W U SCHEDULED Z WIDTH WIDTH 0 LD / \ W _LLI / \ ❑ ❑w J � ❑ w / w x U , W i i 2P1P FG-T (BALCONY DOOR) amenity/common doors update SCHEDULED WIDTH Lrdl Ull. x C7 \ w x ❑ W J w U / / w J � w x U U 1P 2SG 1 PANEL 2 PANEL SLIDING GLASS Nz 2F NG 2NG WINDOW NOTES: 1. SEE PLANS/ELEVATIONS FOR WINDOW TYPE LOCATIONS. 2. PROVIDE CASEMENT WINDOW AT TYPE W UNITS OPERABLE WINDOW LOCATIONS. STYLE TO MATCH 'HUNG' WINDOWS. 3. OPERABLE WINDOWS PROVIDED AT TYPE W UNITS SHALL HAVE AT LEAST ONE WINDOW IN EACH SLEEPING, LIVING OR DINING SPACE WITH ACCESSIBLE CONTROLS AT 15" HIGH MINIMUM AND 48" HIGH MAXIMUM. 4. PROVIDE TEMPERED GLASS AS REQUIRED BY THE STATE BUILDING CODE. 5. ALL WINDOWS TO BE INSTALLED PER WINDOW INSTALLATION DETAILS. 6. WINDOW U VALUE AND SOLAR HEAT GAIN COEFFICIENT TO COMPLY WITH 2O12 NC ENERGY CONSERVATION CODE. 7. REFER TO STRUCTURAL SHEETS FOR WIND LOADS. 8. VINYL WINDOW COLOR: BRONZE 9. OPERABLE WINDOWS IN R-2 OCCUPANCIES SHALL COMPLY WITH SECTIONS 1015.8 & 1015.8.1 OF THE 2018 NCBC. 10. ALL OPERABLE WINDOWS IN PROJECT MUST MEET REUIREMENTS SET BY NCBC 1030. 11. VISIBLE LIGHT TRANSMITTANCE (VLT) SHALL NOT DROP BELOW 40%. 12. VISIBLE LIGHT REFLECTANCE (VLR) SHALL NOT EXCEED 30%. CD v v M x (7 W x W J w 2 W SCHEDULED WIDTH OH1 (GARAGE CRAFTSMAN) + townhome door with sidelite I]] / / El HG 2HG FG SCHEDULED WIDTH W U OH2 (GARAGE CARRIAGEHOUSE) I F 2FG DOOR AND FRAME TYPES 2 1/4" = V-0" WINDOW SCHEDULE Type Mark Height Width COMMENTS Al 4'-8" 2'-6" A2 6'-0" 2'-6" A3 4'-8" 3'-0" A4 6'-0" T-0" A5 4'-0" V-6" A6 4'-6" 2'-0" A7 4'-0" 2'-0" A8 T-0" V-6" A9 6'-0" T-0" A10 2'-0" T-0" C 5' - 10" 2" 2 3 3 1 _6" 3' - 0" 2'- 8" 6„ 2 _8„ 8' HEAD HEIGHT o O ( f0 ❑ ❑ V ■co o o 1 1 0 1 1 i0 1 b co Ll 1 0 1 o Cl) o o (V (V OT (V Al O A3 A4 A5 A6 47 A8 A9 10 FLOOR LEVEL WINDOW TYPE ELEVATIONS DOOR SCHEDULE & HARDWARE SET [-3] WINDOW TYPES 1/4" = 1'-0' 1/4" = 1'-0" 01 16N 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1ineDesignAssoc.com PROJECT: 221074 DATE: 09.26.2022 REVISIONS: DATE DRAWN BY: CW, NS, RES CHECKED BY: JL DOOR / WINDOW SCHEDULES F�T9111 I ---.�aa—•0�00dommomm.— VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM ENTRANCE CORRIDOR SHALL BE ELIMINATED �� i 220 E. Peterson Dr. Charlotte, NC 28217 704/333-7272 C1incDcsigmkssoc.com n Z) O�// ry V Z CW a ^G L.L > O w z w z D 0 -O U z0 w O ry � Q z0� O - m Q U) PROJECT: 221074 DATE: 09.26.2022 REVISIONS: DATE DRAWN BY: CW, NS, RES CHECKED BY: JL ARCHITECTURAL SITE PLAN ARCHITECTURAL SITE PLAN❑ 1" = 50'-0' G1.02