Loading...
HomeMy WebLinkAboutSUB201400094 Approval - County 2014-06-12IL COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 September 15, 2014 Scott Collins Collins Engineering 200 Garrett St., Suite K Charlottesville, VA 22902 RE: SUB201400094 Foothills Crossing II - Preliminary Plat Mr. Collins: The Agent for the Board of Supervisors hereby grants administrative approval to the above referenced subdivision plat. This approval shall be valid for a period of five (5) years from the date of this letter, provided that the developer submits a final subdivision plat for all or a portion of the site within one (1) year after the date of this letter as provided in 14 -226 of the Subdivision Ordinance of the County Code, and thereafter diligently pursues approval of the final subdivision plat. An Erosion and Sediment Control Permit may be issued after the following approvals are received: 1. Approval an Erosion and Sediment Control Plan meeting the requirements of Chapter 17 of the Code of the County of Albemarle. 2. Approval of a Stormwater Management Plan meeting the requirements of Chapter 17 of the Code. 3. Approval of all easements for facilities for stormwater management and drainage control. 4. Approval of a mitigation plan for the disturbance of Water Protection Ordinance buffers. 5. Submittal of a tree conservation checklist. The final subdivision plat will not be considered to have been officially submitted until the following items are received: 1. A final subdivision plat that satisfies all of the requirements of 14 -226 of the Subdivision Ordinance. 2. A fee of $1,230. Please submit six (6) copies of the subdivision plat to the Community Development Department. The assigned Lead Reviewer will then distribute the plans to all reviewing agencies. Once you receive the first set of comments on the final subdivision plat, please work with each reviewer individually to satisfy their requirements. The final subdivision plat will not be approved until the following conditions are met: The Department of Community Development shall not accept submittal of the final subdivision plat for signature until tentative approvals for the following conditions have been obtained: Planning Division Approval of (2 copies): 1. A plat meeting all the requirements for final subdivision plats per the subdivision ordinance. 2. [14 -422] Sidewalks and planting strips. Provide planting strips and sidewalks on private roads. Sidewalks and planting strips for street trees and other vegetation shall be established on both sides of each new street within a subdivision creating lots for single family detached and single family attached dwellings in the development areas. This requirement can be varied or excepted by the commission as provided in section 14- 203.1. 3. [14.401] Proposed facilities. Show the locations of proposed on street parking. Parking calculations will need to be provided on final plat. 4. [2.2.3] Cluster Development — Open Space. Show square footage or acreage of open space segments on plat and provide calculations to show that 25% open space requirement is met for each zoning district. Open space does not need to be located entirely within each zoning district, but calculations should be provided to show that requirements are met for both R -2 and R -6 zoning districts. 5. [14- 302(A) 5] Public easements. A public road is shown extending on to Tax Map Parcel 56 -57B. This property owner will need to be party to the public road easement. 6. [14 -409] Continuation and extension of streets. Extend Maryland Street all the way to the property line if possible. If not, reserve remaining portion between street and property line for future public use. 7. [14 -317] Instrument evidencing maintenance of certain improvements. Submit with the final plat an instrument assuring the perpetual maintenance of the private streets and alleys, street trees, open space and any other improvements that are to be maintained in perpetuity. 8. [14 -311] Infrastructure improvement plans. Road plans are required with submittal of final plat and must be approved prior to approval of final plat. 9. [14 -312] Location of existing buildings. Show location of all existing buildings within fifty feet of lot lines on final plat. Please contact Rachel Falkenstein at 296 -5832 if you have questions or require additional information. Engineering Division Approval of (1 copy of site plan; WPO and road plans to be submitted separately): SUB201400094 — Preliminary Plat (A plat is a record of property division or reservation. Code Chapter 14) 1. Show steep slopes on TM parcel 056A2 -01 -61 —ref County GIS. [ 14- 302.A.12 ] 2. Label TM parcel 056A2 -01 -61 (sheet 2; boundary is shown). 3. Show limits of clearing on sheet 5, ref. tree line, sheet 2. [14- 302.A.12 ] 4. Delete roadway pavement lane arrows /diamonds, inset, sheet 5. 5. Revise Lots 7 and 8; relocate outside stream buffer. 6. Furnish conceptual stormwater management plan. [ 14- 305.A. ] 7. Provide mitigation concept plan for stream buffer impacts. [ 14- 305.13. ] 8. ACSA approval required. 9. VDOT approval required. 10. ACF &R approval required. 11. Show easements or ownership of private alleys. 12. Clearly show and label storm drain easement, south edge of SWM basin, sheets 4/5. 13. SWM, ESC plan approval required. Furnish copy of unexpired VPDES permit (if issued) — link to VPDES letter: http : / /www.aIbemarle.org /navpages .asp ?info= release &ID =17545 14. Submit WPO (VSMP SWM /ESC) and road /drainage plans for review. SUB201400094– Required with Final Plat Sec. 14 -311: "detailed plans, computations and necessary supporting documents for all physical improvements including, but not limited to, road plans, drainage plans and computations, erosion and sediment control plans and stormwater management plans and computations as required by the water protection ordinance, landscape plans, water and sewer plans and computations as required by the service authority, flooding computations and plans if applicable, and any other documents deemed necessary by the county engineer. The plans, computations and necessary supporting documents shall also be submitted to other appropriate agencies." Plans referenced in Sec. 14 -311 must be approved prior to final plat approval. Road Plan comments, preliminary: 15. Lots 1, 13, 14, 21, 22, 23 front public streets: Fremont St., Newport St, and Binion St. Driveway entrances for these lots –if located as far from Park Ridge as possible and vehicles turning off Park Ridge Drive — provide quite limited sight distance. Caution against limited sight distance for driveway entrances. 16. Newport Street (public street) bears north, turns 90 -deg west onto a private road. This design is unacceptable. The 90 -deg bend is not an intersection but break in alignment. Newport St should be designed as a continuous public road between Park Ridge Drive and NW corner of block B, or as a private road. Design of a private road serving twelve lots must meet VDOT standards, including 200' min centerline radius, minimum stopping and intersection sight distances, and min. paved width (24', FC /FC). Eliminate 90 -deg bend. 17. Private road serving twenty lots (blocks J -L) must meet VDOT standards, including min. sight distance, min. paved width (24', FC /FC). 18. For roadways labeled private, follow Albemarle County Code Sections 14- 233/234; 14 -306: private street request procedures. 19. Private road and private alley parallel to Park Ridge Drive do not meet minimum intersection sight distance requirements; show intersection sight distance lines for Maryland St.- private road intersection. [AC 18 -4.4] 20. Five intersection sight distances lines appear to be < 335'; please note which sight distance lines are < 335' –ref. Note 1, sheet 3. [122', 275', 280', 280', 280'] 21. Increase radius of curb at intersection, Private Alley and Newport St, to 25' [if alley retained, ref 20, above –VDOT Road Design Manual, Appendix 131.4.E.- Elements of Typical Section, Intersections]. 22. Increase radius of curb at intersection, Private Alley and Park Ridge Drive, to 25'. 23. Label intersection radii at private alley - private alley, E -NE corner of development. 24. Alley N of block A: show width. Dead -end alleys with turnarounds may permitted by waiver from the County Engineer. Apply for waiver. Furnish flanking storm drains at intersection: Alley N of block A- Fremont St. [ ACDSM, 7. D.4. ] 25. Furnish retaining wall design (engineering details and computations) for proposed retaining wall; ref. ACDSM - 8.13.2. [link: http: / /www.albemarle.org/ department. asp ?department= cdd &relpage =4447 ] 26. Drainage –check all flow line arrows: there is apparent error at several locations, including: south arrow in pipe between block E and F; leaving inlet on Park Ridge between block E and F; west into inlet on Binion St; and east and then north into inlet on Park Drive. 27. Furnish inlet on Fremont St, south of Private Alley. 28. Furnish additional inlets at these intersections: Maryland St -Park Ridge Dr.; Maryland St -Pvt. Road to ensure drainage does not flow into intersected roadway. 29. Drainage /cul -de -sacs: compare inlet locations with driveway entrances. Provide drain inlets that divert runoff away from driveway entrances (Lots 6 -9; 17 -20). 30. Provide CG -12, NW corner, Park Ridge Dr.- Fremont St. intersection. 31. Furnish inlet /pipe schedules and calculations. 32. Label curb type (roll -top / CG -6, etc). 33. Show traffic controls. 34. WPO comments, preliminary: 35. Furnish outlet protection for storm pipe discharging to SE corner of proposed SWM facility. 36. Furnish copy of DEQ VPDES permit (VAR10C610). 37. Extend 100' stream buffer from TM parcel 05600- 00 -00- 09400, west onto TM parcel 05600 -00- 00- 05700. 38. Show access to proposed SWM facility. [ ref § AC 14 -431 ] 39. Furnish easement for access for proposed SWM facility. [ AC 14 -431 ] 40. Furnish design, plan /profiles, data, and routings for SWM facility, demonstrating compliance with quality and quantity criteria using the Runoff Reduction Method, (2- /10 -yr storm events). 41. Provide Mitigation for stream buffer impacts: pipe outfall, SWM facility; utility line between lots 7 and 8. Please contact John Anderson at 296 -5832 if you have questions or require additional information. ACSA approval to include (1 copy to County, 3 copies to ACSA): The applicant should submit 3 copies of construction drawings along with water and sewer data sheets to the ACSA (Attn: Jeremy Lynn, PE). See attached comments from ACSA Please contact Alex Morrison at 977 -4511 ext 116 if you have questions or require additional information. E911 approval to include (1 copy): 1. The applicant should clarify if Blocks J, K, and L will have the front accesses located. It appears that the homes in these blocks will be facing the 'Private Road'. This road will need to be named if it will be the primary access to the properties. The 'Private Road' providing access to Blocks B, C, D, and Lot 85 will need to be named. Please contact this office with a list of three (3) proposed road names for the 'Private Roads' in question. Please contact Andrew Slack at 296 -5832 if you have questions or require additional information. VDOT approval to include (1 copy): 1. The sight lines are shown on the preliminary plat, however the distances should be included also. 2. It appears that the street trees on the north side of Park Ridge Drive to the east of Newport Street may interfere with the sign distance at Newport Street 3. All street trees should be located at a minimum of 30' from the end of radius at each intersection in accordance with Appendix B(1) of the Road Design Manual. This can be addressed during road plan review. 4. As designed, Newport Street to the north of Park Ridge Drive would need to be a private road due to the lack of adequate turnaround and the perpendicular parking at the tot lot. 5. Street intersections, public of private, should be perpendicular of each other. 6. The minimum radii at each intersection should be 25'. 7. Maryland Street and the private alley on the opposite side of Park Ridge Drive should be aligned with each other. 8. The typical section for an Avenue in the Crozet Masterplan shows accommodations for bicycle travel, however the typical street sections shown in the preliminary plat does not address this issue. 9. The Typical Neighborhood Street Section (57' R /W) indicates parking on one side of the street. Neither the typically section nor the plan view indicates which side of the streets will be used for on street parking. Please note that on street parking may interfere with available sight distance. 0 10. The asphalt paving design provided may interfere with available sight distance. 11. Based on the Crozet Masterplan, Park Ridge Drive would need to connect to Hill Top Street. There appears to be a parcel of land that is owned by the Parkside Village HOA that would prevent this connection without the support of the HOA. Please contact Troy Austin at 422 -9373 if you have questions or require additional information. If you have any questions about these conditions or the submittal requirements please feel free to contact me at Extension 3272, rfalkenstein @albemarle.org. Sincerely, " W-�� Rachel Falkenstein, AICP Senior Planner