Loading...
HomeMy WebLinkAboutSUB201400006 Approval - Agencies 2014-01-10In Cooperation with the State Department of Health t'I COMMONWEALTH of VIRGINIA Thomas.Jefferson Health District 1138 Rose Hill Drive Phone (434) 972 -6219 P. 0. Box 7546 Fax (434) 972 -4310 Charlottesville, Virginia 22906 January 30, 2014 Ellie Carter Ray, Senior Planner Department of Community Development Division of Zoning and Current Development 401 McIntire Road Charlottesville, Virginia 22902 -4596 ALBEMARLE - CHARLOTTESVILLE FLUVANNA COUNTY (PALMYRA) GREENE COUNTY (STANARDSVILLE) LOUISA COUNTY(LOUISA) NELSON COUNTY (LOVINGSTON) RE: Review of Proposed Subdivision Plat and attached Soils Information for Individual Onsite Sewage Systems as part of a division of Tax Map 55 Parcel 23 located in Albemarle County, Virginia. Dear Ms. Ray: On January 15, 2014, the County of Albemarle requested the Virginia Department of Health (via the Albemarle County Health Department) review the proposed subdivision plat identified above. This letter is to inform you that the above referenced subdivision plat is approved for individual Onsite Sewage Systems in accordance with the provisions of the Code of Virginia, the Sewage Handling and Disposal Regulations, and local ordinances. This request for subdivision review was submitted pursuant to the provisions of § 32.1 -163.5 of the Code of Virginia which requires the Health Department to accept private soil evaluations and designs from an Authorized Onsite Soil Evaluator (AOSE) or a Professional Engineer working in consultation with an AOSE for residential development. This subdivision was certified as being in compliance with the Board of Health's Regulations by: Stephen P. Gooch, OSE #1940001284. This subdivision approval is issued in reliance upon that certification. Pursuant to § 360 of the Regulations this approval is not an assurance that Sewage Disposal System Construction Permits will be issued for any lot in the subdivision identified above unless that lot is specifically identified on the above referenced plat as.having an approved site for an onsite sewage disposal system, and unless all conditions and circumstances are present at the time of application for a permit as are present at the time of this approval. This subdivision may contain lots that to do not have approved sites for onsite sewage systems. This subdivision approval does pertain to the requirements of local ordinances. Sincerely, Travis T. Davis Environmental Health Specialist, Sr. oe i', ' t, ,lico - ,„ 1 0". 1 i ',..., '1 A 1* f, i 1 '11 i , I A 3 ,, sk , v , , gt4glY F;'-' *".,/ 1 k Soils Study for Drain Field Sites Parcels 1-3 A Rural Division of Tax Map 55-23 The Marjorie M. Milliman Property Albemarle County .....„ Prepared for: Marjorie M. Milliman P.O. Box 66 Crozet, Virginia 22932 Prepared by: Steve Gooch Consulting Geologist, Inc. 703 Oliver Creek Road Troy,Virginia 22974 January 11, 2014 ....... Page 1 of 5 OSE/PE Report for: Construction Permit I I Certification Letter [1 Subdivision Approval 171 l ps Property Location: IT- 911 Address: 6577 Jarmans Gap Road g= ;" : �; t *4! Lot 1 Section Su tston it Im=n P ••erty ' ` GPIN or Tax Map# 55-23 Health Dept ID# Latitude Longitude Applicant or Client Mailing Address: Name: Marjorie Milliman Street: P.O. Box 66 City:Crozet State Virginia Zip Code 22932 Prepared by: OSE Name Steve Gooch License# 1940001284 Address 703 Oliver Creek Road City Troy State Virginia Zip Code 22974 PE Name: License# Address City State Zip Code Date of Report 1/11/14 Date of Revision#1 OSE/PE Job# Date of Revision#2 Contents/Index of this report(e.g.,Site Evaluation Summary,Soil Profile Descriptions,Site Sketch,Abbreviated Design,etc.) OSE Cover Page Abbreviated Design Form Soil Profile Sheet Survey Plat Soil Information Summary Sheet Certification Statement I hereby certify that the evaluations and/or designs contained herein were conducted in accordance with the Sewage Handling and Disposal Regulations(12 VAC5-610),the Private Well Regulations(12 VAC5-630)and all other applicable laws,regulations and policies implemented by the Virginia Department of Health. I further certify that I currently possess any professional license required by the laws and regulations of the Commonwealth that have been duly issued by the applicable agency charged with licensure to perform the work contained herein. 1-1-11 The work attached to this cover page has been conducted under an exemption to the practice of engineering,specifically the exemption in Code of Virginia Section 54.1-402.11 I recommend that a(select one): onstruction permit❑ certification letter subdivision approval 5 be(select one)issued 0 denied . .r `/ OSE/PE Signature 5�'�ac?� [l Date [thy Puy` 2 i - Soil Profile Reserve Drain Field Parcel 1 A Division of Tax Mail, AParelc237 �A ., 'k ,., Albemarle C (1; A 0 t ki -*4 Hole Depth Horizon Material Description r Soil Texture (in.) Group 17 0-6 A Reddish brown(2.5YR 4/3) clay loam 3 6-60 Bt Red (10R 5/8) silty clay loam 3 18 0-6 A Reddish brown(2.5YR 4/3) clay loam 3 6-42 Bt Red(10R 5/8) silty clay loam with gravel and cobbles 3 below 36" 42- - 50%+gravel and cobbles 19 0-6 A Reddish brown(2.5YR 4/3) clay loam 3 6-38 Bt Red(10R 5/8) silty clay loam with gravel and cobbles 3 38- - 50%+ gravel and cobbles 20 0-7 A Reddish brown(2.5YR 4/3) clay loam 3 7-42 Bt Red(1 OR 5/8) silty clay loam with gravel and cobbles 3 below 36" 42- - 50%+ gravel and cobbles 21 0-6 A Reddish brown(2.5YR 4/3) clay loam 3 6-46 Bt Red(10R 5/8) silty clay loam with gravel and cobbles 3 below 40" 46- - 50%+ gravel and cobbles 22 0-4 A Reddish brown(2.5YR 4/3) clay loam 3 4-48 Bt Red(10R 5/8) silty clay loam with gravel and cobbles 3 below 40" 48- - 50%+gravel and cobbles 23 0-5 A Reddish brown(2.5YR 4/3) clay loam 3 5-38 Bt Red(1OR 5/8) silty clay loam with gravel and cobbles 3 38- - 50%+gravel and cobbles 24 0-4 A Reddish brown(2.5YR 4/3)clay loam 3 4-48 Bt Red(10R 5/8) silty clay loam with gravel and cobbles 3 below 44" 48- - 50%+gravel and cobbles Page 3 of Appendix 2 Soil Summary R $ ort g GENERAL INFORN ,;,s �: <RR . Date 1/11/14 Submitted to Albemarle County —Hea Dep rtmen Applicant Majorie Milliman Telephone Number (434) 823-4810 Address P.O. Box 66 Crozet,Virginia 22932 Owner same Address same Location 6577 Jarmans Gap Road Tax Map 55-23 Subdivision Milliman Property Block/Section Lot 1 SOIL INFORMATION SUMMARY 1. Position in landscape satisfactory? I—X Yes I— No Describe side slope 2. Slope 12 % 3. Depth to rock or impervious strata: Max. 60"+ Min. 38" None 4. Depth to seasonal water table(gray mottling or gray color) R. No E Yes inches 5. Free water present f No r Yes range in inches 18-30" 3. Soil percolation rate estimated (X Yes Texture group I II doo IV ,..► (� No Estimated rate 90 min/inch 7. Permeability test performed r Yes R. No If yes, note type of test performed and attach R. Site Approved: Drainfield to be placed at 6" depth at site designated on permit. f Site Disapproved: Reasons for rejection: 1. E Position in landscape subject to flooding or periodic saturation. 2. E Insufficient depth of suitable soil over hard rock. 3. E Insufficient depth of suitable soil to seansonal water table. 4. I— Rates of absorption too slow. 5. I" Insufficient area of acceptable soil for required drainfield, and/or Reverse Area. 6. f Proposed system too close to well. 7. f Other Specify (attach additional pages if necessary) POT.- y 07-5 Abbreviated Design Form This form is for use with gravity,pump to gravity,enhanced flow,and low pressure distribution(LPD)sewage system designs and when applying for a certification letter or subdivision approval. This abbreviated design covers the ❑ primary and reserve area, • only the primary area, my the reserve area(check one)for Parcel 1 —A Division of TM 55-23 (Pro. qt ID . le r : , Design Basis v _ ° ' 4 " Total length of available area: 100' Total width of available area: 100' Estimated Perc. Rate: 90 at 6� in. (depth) Number of bedrooms(or GPD): 3 Conveyance Methods 2 : Pump Distribution method (specify): Pump 3c Dispersal system basis Table 5.4(LPD) LGMI required? No (Yes/No) Effluent quality required: Secondary (Primary, Secondary,Advanced Secondary) Square feet per bedroom: 424 Total trench bottom area required: 4464* *includes 17% increase for slope Now, Area Calculations Number of trenches 23 Length of trenches:_100' Width of trenches: 1" Center to center spacing: 2' Reserve required?_This is reserve _ Percent reserve area required: 100 Total width of absorption area required 44' Total trench bottom area provided: 4600 The required width is calculated by multiplying the center-to-center spacing by one less than the number of trenches and adding 1 trench width plus any required reserve area. If the topography is not uniform across the length of the site the trenches will need to flare apart on one end to maintain contour. When this occurs it is necessary to use a center-to-center spacing that accounts for the flair or the installer will not be able to fit the system within the approved area. It is perfectly acceptable to have more area available,especially up and down the slope,than is required. ``o."` Page of AOSE Form E Revised July 18,2007 �� P 0 N.D 1; �t! r� / � at1F � �, L33 \ 25. l s. \.3R ," IRON l32 '` :;;-1 2 10. 3�Cp, t-7 L35 ,.. FOUND L9 Lg_ IS 4.go: / IRON f IRON--� IS ;; •i1 _ - r, FOUND l CZ) FOUND e29 FLAG 4 EPA 6UFF�F IS r ca CZ tr 93 #22 00,S A ,' .. 4 J . . ■ 4' FLAG I 4,., Q - FLAG ;,..,eas. 928 X23 •ten.aC nn»�,� ,1.4 I . 'N4/4'(r)Ct 'C� X18 `� FLAG PROPOSED RESERVE -ti Q r`o EXISTING HOUSE-_-- f``21 0.'93s FLAG DRAIN FIELD ^ .� +,(ti,Z(-) i (') r i (APPROX.) 'J FLAG FLAG ([)U Lu Sr�d (D ® 424 p0 r rl:CC V . EXISTING WELL ...-67.._v CE ! r�� p)� v > (APPROX.) ' ' l•-• d • EXISTING DRAIN FIELD <0 P m v-irr) (APPROX.) �+ a 2ti Y uP, IRON .. �)p : FOUND IRON FOUND > ,/" �2 \\. AT 5.00' S7 (N?C∎- 317 B22'•t- 0) .,pp1),,94- CORNER FENCE ' PIPE �n> j IN POST FOUND . PARCEL 1 88. 50 ACRES SiaEAM o o - ------- 1. , 15. Ss�". 4,;) T.M.55-29C 1 S`S9" 66 APPROX. 0' UNIMPROVED • � LOCATION J 60. ' _ ROAD STREAM ��° ti� el). -' ' N64 '25'44"W ;' PIPE FOUND , t, 160.93' AT 5.94' IRON SET ,(1� ;C ' <<./ UNIMPROVED Z, � c3 , Sr �.. . , 02' ROAD co <'N`► = �/�,� � 0 'r. � Cq� S9 /41 m IS ROCK 4I,(v WALL ' , ';!, ) ;;'Q` IS i?/1, ' LZ Scale 1"= 300' .- Soil Profile Hole PARCEL 3 to/ ic4i House, Well and Drain Field Sites tiev; � IS �� Parcel 1 Q�,w0 % . % A Division of Tax Map 55-23 °ni Pi ' icy Q6)- , \4' �. Albemarle County, Virginia 411?//k/ v ÷ Steve Gooch Consulting Geologist '' ► '�' ` 703 Oliver Creek Road 2'``QQ ° Tro , Vir.inia 22974 ' ', 1 Page 1 of 6 OSE/PE Report for: "ft.- Construction Permit I Certification Letter Subdivision Approval L! 1,4' k Pl it rasa ", > .1 r= x ,r. Property Location: , 1` 91 1 Address: 6577 Jarmans Gap Road ,� : I 2 Milkman roper Lot Section Subdivision GPIN or Tax Map# 55-23 Health Dept ID# Latitude Longitude Applicant or Client Mailing Address: Name: Marjorie Milliman Street: P.O. Box 66 City:Crozet state Virginia Zip Code 22932 Prepared by: OSE Name Steve Gooch License# 1940001284 Address 703 Oliver Creek Road City Troy state Virginia Zip Code 22974 PE Name: License# Address `40' City State Zip Code Date of Report 1/11/14 Date of Revision#1 OSE/PE Job# Date of Revision#2 Contents/Index of this report(e.g.,Site Evaluation Summary,Soil Profile Descriptions,Site Sketch,Abbreviated Design,etc.) OSE Cover Page Abbreviated Design Forms Soil Profile Sheet Survey Plat Soil Information Summary Sheet Certification Statement I hereby certify that the evaluations and/or designs contained herein were conducted in accordance with the Sewage Handling and Disposal Regulations(12 VACS-610),the Private Well Regulations(12 VAC5-630)and all other applicable laws,regulations and policies implemented by the Virginia Department of Health. I further certify that I currently possess any professional license required by the laws and regulations of the Commonwealth that have been duly issued by the applicable agency charged with licensure to perform the work contained herein. 1Z The work attached to this cover page has been conducted under an exemption to the practice of engineering,specifically the exemption in Code of Virginia Section 54.1-402.11 I recommend that a(select one): construction permit❑ certification letter subdivision approval is be(select one)issued 0 denied❑. OSE/PE Signature ) 1IJ . ehreTj(iL- Date i/it l-1 ?ayQ Z � ‘ Soil Profile Parcel 2 A Division of Tax Map 55 Parcel 23 { Albemarle Coy Hole Depth Horizon Material Description = ,; i r. t 1r 1 exture (in.) % ;, ou 1 0-6 A Reddish brown(2.5YR 4/3) clay loam 3 6-42 Bt Red(10R 5/8) silty clay loam 3 42- 50%+gravel and cobbles 2 0-8 A Reddish brown(2.5YR 4/3) clay loam 3 8-44 Bt Red(10R 5/8) silty clay loam 3 44 50%+gravel and cobbles 3 0-7 A Reddish brown(2.5YR 4/3) clay loam 3 7-42 Bt Red(10R 5/8) silty clay loam 3 42- 50%+gravel and cobbles 4 0-4 A Reddish brown(2.5YR 4/3)clay loam 3 4-45 Bt Red(10R 5/8) silty clay loam 3 45-60 Bt2 Strong brown(7.5YR 5/8) silty clay loam, occasional 3 gravel, manganese 5 0-3 A Reddish brown(2.5YR 4/3) clay loam 3 3-24 Bt Red(10R 5/8) silty clay loam 3 24-60 BC Red(10R 5/8) silty clay loam and yellowish brown 3 (10YR 5/8) silt loam 6 0-5 A Reddish brown(2.5YR 4/3) clay loam 3 5-19 Bt Red (10R 5/8) silty clay loam 3 19-60 Bt2 Yellowish red(5YR 5/8) silty clay loam 3 7 0-4 A Reddish brown(2.5YR 4/3) clay loam 3 4-17 Bt Red(1OR 5/8) silty clay loam 3 17-60 Bt2 Yellowish red(5YR 5/8) silty clay loam 3 8 0-6 A Reddish brown(2.5YR 4/3)clay loam 3 6-21 Bt Red (10R 5/8) silty clay loam 3 21-60 Bt2 Yellowish red(5YR 5/8) silty clay loam 3 Page 3 of 4 Appendix 2 Soil Summary R , ort GENERAL INFOR OI ; rYll i Date 1/11/14 Submitted to Albemarle County )He h Niaortnlent Applicant Majorie Milliman Oeleph&e Number (434) 823-4810 Address P.O. Box 66 Crozet, Virginia 22932 Owner same Address same Location 6577 Jarmans Gap Road Tax Map 55-23 Subdivision Milliman Property Block/Section Lot 2 SOIL INFORMATION SUMMARY 1. Position in landscape satisfactory? fx Yes f— No Describe side slope 2. Slope 18 % 3. Depth to rock or impervious strata: Max. 60"+ Min. 42" None 4. Depth to seasonal water table(gray mottling or gray color) x No E Yes inches 5. Free water present R. No E Yes range in inches ). Soil percolation rate estimated fX Yes Texture group I II III IV I No Estimated rate 90 min/inch 7. Permeability test performed r Yes No If yes, note type of test performed and attach R Site Approved: Drainfield to be placed at 24" depth at site designated on permit. I" Site Disapproved: Reasons for rejection: 1. E Position in landscape subject to flooding or periodic saturation. 2. I— Insufficient depth of suitable soil over hard rock. 3. r Insufficient depth of suitable soil to seansonal water table. 4. r Rates of absorption too slow. 5. E Insufficient area of acceptable soil for required drainfield, and/or Reverse Area. 6. I` Proposed system too close to well. 7- E Other Specify (attach additional pages if necessary) Pcmc- oc-6. Abbreviated Design Form This form is for use with gravity,pump to gravity,enhanced flow,and low pressure distribution(LPD)sewage system designs and when applying for a certification letter or subdivision approval. This abbreviated design covers the ❑ primary and reserve area, o the primary area, ❑ only the reserve area(check one)for Parcel 2—A Division of TM 55-23 (Property lot. re'"a Design Basis Total length of available area: 100' Total width of available area: 105' Estimated Perc.Rate: 90 at 24" in.(depth) Number of bedrooms(or GPD): 4 Conveyance Methods 2 : Gravity Distribution method (specify): Gravity 3c Dispersal system basis Table 5.4 LGMI required? No (Yes/No) Effluent quality required: Primary (Primary, Secondary,Advanced Secondary) Square feet per bedroom: 786 Total trench bottom area required: 3144 Area Calculations Number of trenches 11 Length of trenches: 100' Width of trenches: 3' Center to center spacing: _10' Reserve required? Yes Percent reserve area required: 100 Total width of absorption area required 103' Total trench bottom area provided: 3300 The required width is calculated by multiplying the center-to-center spacing by one less than the number of trenches and adding 1 trench width plus any required reserve area. If the topography is not uniform across the length of the site the trenches will need to flare apart on one end to maintain contour. When this occurs it is necessary to use a center-to-center spacing that accounts for the flair or the installer will not be able to fit the system within the approved area. It is perfectly acceptable to have more area available,especially up and down the slope,than is required. Page of AOSE Form E Revised July 18,2007 24c ) 0 Abbreviated Design Form This form is for use with gravity,pump to gravity,enhanced flow,and low pressure distribution(LPD)sewage system designs and when applying for a certification letter or subdivision approval. This abbreviated design covers the ❑ primary and reserve area, 0 only.the primary area, only the reserve area(check one)for Parcel 2—A Division of TM 55-23 (Property II r 1 Design Basis Total length of available area: 100' Total width of available area: 60' Estimated Perc. Rate:90 at 24" in.(depth) Number of bedrooms(or GPD): 4 Conveyance Methods 2 : Gravity Distribution method (specify): Gravity 3c Dispersal system basis GMP 118A LGMI required? No (Yes/No) Effluent quality required: Secondary (Primary, Secondary, Advanced Secondary) Square feet per bedroom: 306 _ Total trench bottom area required:_1224 Area Calculations Number of trenches 6 Length of trenches: 100' Width of trenches: 3' Center to center spacing: 10' Reserve required? This is reserve _ Percent reserve area required:__100 Total width of absorption area required 53' Total trench bottom area provided:_ 1800 The required width is calculated by multiplying the center-to-center spacing by one less than the number of trenches and adding 1 trench width plus any required reserve area. If the topography is not uniform across the length of the site the trenches will need to flare apart on one end to maintain contour. When this occurs it is necessary to use a center-to-center spacing that accounts for the flair or the installer will not be able to fit the system within the approved area. It is perfectly acceptable to have more area available,especially up and down the slope,than is required. Page of AOSE Form E Revised July 18,2007 ,-2,,,, - . .. ' �' i -ViH(i1N!A LE1(iH MCCAULEY E �15�4,s, <,I ' / D.B.3526-539 " ,:,., °e '.ors, ' D.13. 1314-53 PLAT z ' ¢" P a' 4 D.B.207-240 PLAT o 6 f' t,.: =r.: lioW,t , , STATE ROUTE 69 4 ;,-o 4 ..-d� �j�, \ JARMANS GAP ROAD �� I : . c} (30'PRESCRIPTIVE EASEMENT) STREAM T.M.55-34 �4 BUFFER DAVID_ H.CHARTERS .ESTATE FLAG' );I PAVED ._j \ W.B.79-482 f13 DRIVEWAY STS.: FLAG IS, ; EAM.:... :yA C8 D.8.338-469 PLAT IS o . FLAG co ; \ C 49 ,, J HOC _ _L6 32 ;1 3s PROPOSED PRIMARY FLAG ��C,. P r .LAG ^ ,./? i . . DRAIN FIELD #a , " 'k.A... :lN IRON FLAG 3.. _.. y0L Z.,.... FOUND :1- �, NEW 50 & VARIABLE m e _+_ :..:C,94:Fk , � AT 24. 15' WIDTH PRIVATE ''• FLA 'jL .._,;.�.:.::: '/ S . CESS EASEMENT° ! 1 es .o'-. FLAG _ " ....'.h IS yOSED WELL; PROPOSED HOUSif6 FLAG `pmv ' v 1 F. SITE FLAG PROPOSED RESERVE -., �� tU "-f L i DRAIN FIELD q> ^ � 1L s P PARCEL / L°' 3 „; „IS 50: 00 A C'H =-S L15 R� •--.--- • IS �p 1 .'. t v END PRIVATE ti� <• ACCESS ESMT. IS P ..\` _i_.____------00.siVer'' SA'- -... ;; _ 1 p 31' , Iq 8 IS ,' L11 !9 La_ IS 0. FLAG FLAG N29 N20 FLAG EpA BUF�E� IS FLAG 832: '" :28 = #23 �oo N6.9 °46'02"'W v1 #18 FLAG 339.BO' nj� X21 o.,836, FLAG . TOTAL o, FLAG FLAG •2 ��V// ® #17 #24 �� PROPOSED FENCE DAAINFIELD ... AREAS R T.M.55-80 �0 ROSELAND FARM. LLC tit D.B. 4063-736 D.B.4412-40 & 41 PLAT D.8.4063-740 &741 PLAT IATN5FOUND Scale 1"= 300' Q- Soil Profile Hole �. �A sib 1�q Q2 House, Well any Drain Field Sites• 'AC4''9go� F .g2, Parcel 2 •O ),r-1-•, CORNER ENCE ' PIPE 1> °4; " IN POST . FOUNE A Division of Tax Map 55-23 is..... - Albemarle County, Virginia RES Steve Gooch Consulting Geologist �ofv.�,--- 703 Oliver Creek Road slAEP'M O Troy, Virginia 22974 Page 1 of 6 OSE/PE Report for: Construction Permit r Certification Letter I I Subdivision Approval I• 1 Property Location: 911 Address: 6577 Jarmans Gap Road r n Lot 3 Section Subdivision Millimafil Pro eift+)t'' a ' � .-, 23 GPIN or Tax Map# 55- Health Dept ID# Latitude Longitude Applicant or Client Mailing Address: Name: Marjorie Milliman Street: P.O. Box 66 City:Crozet State Virginia Zip Code 22932 Prepared by: OSE Name Steve Gooch License# 1940001284 Address 703 Oliver Creek Road City Troy State Virginia Zip Code 22974 PE Name: License# Address e City State Zip Code Date of Report 1/11/14 Date of Revision#1 OSE/PE Job# Date of Revision#2 Contents/Index of this report(e.g.,Site Evaluation Summary,Soil Profile Descriptions,Site Sketch,Abbreviated Design,etc.) OSE Cover Page Abbreviated Design Forms Soil Profile Sheet Survey Plat Soil Information Summary Sheet Certification Statement I hereby certify that the evaluations and/or designs contained herein were conducted in accordance with the Sewage Handling and Disposal Regulations(12 VACS-610),the Private Well Regulations(12 VACS-630)and all other applicable laws,regulations and policies implemented by the Virginia Department of Health. I further certify that I currently possess any professional license required by the laws and regulations of the Commonwealth that have been duly issued by the applicable agency charged with licensure to perform the work contained herein. I J The work attached to this cover page has been conducted under an exemption to the practice of engineering,specifically the exemption in Code of Virginia Section 54.1-402.11 I recommend that a(select one): construction permit❑ certification letter subdivision approval 51 be(select one)issued Q denied I]. OSE/PE Signature "/J .ekes ZZ9t& - Date 'hilly Pc4 2oS6 Soil Profile Parcel 3 A Division of Tax Map 55';P 'c9,l,,? ,,:i ..-,-,,,, 1 r ;_;-,-;.„4 ,0-: Albemarle County , t s t" vi 3, M 4r -, Hole Dept h Horizon Material Description ; , Li'.'j4 r of Texture `'.''`t (in.) a� Group 9 0-9 A Reddish brown(2.5YR 4/3) clay loam 3 9-42 Bt Red(10R 5/8) silty clay loam 3 42- 50%+ gravel and cobbles 10 0-10 A Reddish brown(2.5YR 4/3) clay loam 3 10-60 Bt Red(10R 5/8) silty clay loam 3 11 0-11 A Reddish brown(2.5YR 4/3) clay loam 3 11-48 Bt Red (10R 5/8) silty clay loam 3 48- 50%+ gravel and cobbles 12 0-10 A Reddish brown(2.5YR 4/3) clay loam 3 10-30 Bt Yellowish red (5yR 5/8) silty clay loam with gravel and 3 cobbles 30-60 Bt2 Yellowish brown(10YR 5/8) silty clay loam,white 3 feldspar below 48" 13 0-8 A Reddish brown(2.5YR 4/3) clay loam 3 8-20 Bt Red(10R 5/8) silty clay loam 3 20-38 Bt2 Red(2.5YR 5/8) sandy clay loam with gravel and cobbles 2 38- - 50%+gravel and cobbles 14 0-8 A Reddish brown(2.5YR 4/3) clay loam 3 8-38 Bt Red(10R 5/8) silty clay loam 3 38- - 50%+gravel and cobbles 15 0-8 A Reddish brown(2.5YR 4/3) clay loam 3 8-54 Bt Red(10R 5/8) silty clay loam 3 54- - 50%+gravel and cobbles 16 0-6 A Reddish brown(2.5YR 4/3)clay loam 3 6-52 Bt Red(10R 5/8) silty clay loam 3 52- - 50%+gravel and cobbles Page 3 of tG Appendix 2 Soil Summary Report;, !''"'f, , r � 1w r r� r GENERAL INFORMATIcr� , " &r, 4 r �, ■ Ti .w.:,Y` ' ® <.!;3 #;.tr;J ii ti s Date 1/11/14 Submitted to Albemarle County Health Department Applicant Majorie Milliman Telephone Number (434) 823-4810 Address P.O. Box 66 Crozet, Virginia 22932 Owner same Address same Location 6577 Jarmans Gap Road Tax Map 55-23 Subdivision Milliman Property Block/Section Lot 3 SOIL INFORMATION SUMMARY 1. Position in landscape satisfactory? IR Yes E No Describe side slope 2. Slope 7 % 3. Depth to rock or impervious strata: Max. 60"+ Min. 38" None 4. Depth to seasonal water table(gray mottling or gray color) ! No 7 Yes inches 5. Free water present No 7 Yes range in inches 5. Soil percolation rate estimated iX Yes Texture group I II al IV 7 No Estimated rate 90 min/inch 7. Permeability test performed 7 Yes R No If yes, note type of test performed and attach i Site Approved: Drainfield to be placed at 20" depth at site designated on permit. r Site Disapproved: Reasons for rejection: 1. E Position in landscape subject to flooding or periodic saturation. 2. i— Insufficient depth of suitable soil over hard rock. 3. 7 Insufficient depth of suitable soil to seansonal water table. 4. E Rates of absorption too slow. 5. 7 Insufficient area of acceptable soil for required drainfield, and/or Reverse Area. 6. I— Proposed system too close to well. 7. 7 Other Specify (attach additional pages if necessary) u6 Abbreviated Design Form This form is for use with gravity,pump to gravity,enhanced flow,and low pressure distribution(LPD)sewage system designs and when applying for a certification letter or subdivision approval. This abbreviated design covers the❑ primary and reserve area, [l the primary area, ❑ only the reserve area(check one)for_Parcel 3—A Division of TM 55-23 (Property 1;D , .,n r, Design Basis ; �' Total length of available area: 100' Total width of available area: 105' Estimated Perc. Rate: 90 at 20`._�' in. (depth) Number of bedrooms(or GPD): 4 1 2 Conveyance Method : Gravity Distribution method (specify): Gravity 3c Dispersal system basis Table 5.4 LGMI required? No (Yes/No) Effluent quality required: Primary (Primary, Secondary, Advanced Secondary) Square feet per bedroom: 786 Total trench bottom area required: 3144 .• Area Calculations Number of trenches 11 Length of trenches: 100' Width of trenches: 3' Center to center spacing: 9' Reserve required? Yes Percent reserve area required: 100 Total width of absorption area required 93' Total trench bottom area provided: 3300 The required width is calculated by multiplying the center-to-center spacing by one less than the number of trenches and adding 1 trench width plus any required reserve area. If the topography is not uniform across the length of the site the trenches will need to flare apart on one end to maintain contour. When this occurs it is necessary to use a center-to-center spacing that accounts for the flair or the installer will not be able to fit the system within the approved area. It is perfectly acceptable to have more area available,especially up and down the slope,than is required. Page of AOSE Form E Revised July 18,2007 ece-y2- 7 Vc Abbreviated Design Form This form is for use with gravity,pump to gravity,enhanced flow,and low pressure distribution(LPD)sewage system designs and when applying for a certification letter or subdivision approval. This abbreviated design covers the ❑ primary and reserve area, ❑only the primary area, my the reserve area(check one)for Parcel 3 —A Division of TM 55-23 (Property ID). 4 Design Basis 1 7 Total length of available area: 60' Total width of available area: 16 , Estimated Perc.Rate: 90 at 20" in. (depth) Number of bedrooms(or GPD): 4 1 2 Conveyance Method : Gravity Distribution method (specify): Gravity 3c Dispersal system basis GMP 118A LGMI required? No (Yes/No) Effluent quality required:_Secondary (Primary, Secondary, Advanced Secondary) Square feet per bedroom: 306 Total trench bottom area required:_1224 Area Calculations Number of trenches 10 Length of trenches: 60' Width of trenches: 3' Center to center spacing: 9' Reserve required?_This is reserve_ Percent reserve area required: 100 Total width of absorption area required 84' Total trench bottom area provided: 1800 The required width is calculated by multiplying the center-to-center spacing by one less than the number of trenches and adding 1 trench width plus any required reserve area. If the topography is not uniform across the length of the site the trenches will need to flare apart on one end to maintain contour. When this occurs it is necessary to use a center-to-center spacing that accounts for the flair or the installer will not be able to fit the system within the approved area. It is perfectly acceptable to have more area available,especially up and down the slope,than is required. Page of AOSE Form E Revised July 18,2007 07f 194.39 386.22 S78 °21 '45"El EASEMENT FOR 445' MARZENE J.FRYE-GIBSON SIGHT DISTANCE D.B. 4187-700 ` i. t` (D.8.4117-375 Q. (7,Q D.B.915-723 PLAT S 376 PLAT) n cr IRON \� �' Q ,�� �4�j� oF� ATF20.00' = \cam Q Q� ``� D. i'pill;.. 4., r�� / T.M.55-2901 ►' N24 •27,..11"E rl `'ogaro�� � CO1,' �, / DAVID 0. WEST & 100.00' .- . '`�4;_ ;',-/-' I MARGARET B.WEST TOTAL 80.00.40.4;. ,,0 , /D.B.832-156, 158 PLAT IRON '♦� ' FOUND:_:.....:: : - �� eLe SEE / ���`§ DETAIL T.M.55-9 , r' FEB P .1ps / 0�F , �4,. C . L23�r JULIA D.WILEY rye L24 0.8.3222-708, / -� 4r4/40,4147-c'�� 3 L22 '15 & 715A PLAT w� +., ,C4 C ! � ��\ S livitta.:„.„.7p7-e„.,:y. N•-47p44 pie,.i, .. I m PARCEL 3 ' . � / (° 45. 74A „`� r y ACRES --- . / FLAG /•%'' PAVED _._ PROPOSED PRIMARY FLAG 4'13 FLAG DRIVEWAY 9 R �;, i DRAIN ai_ 5 IS„.'' IS FLAG FG iii F4 . : PPI .OPOSED RESER V E r PROPOSED HOUSE n io 6 3y DR.A N FIELD„ , r h SITE FLAG ..14' i9 ^ G 7.M.55-10 / m mGRAVEL m HENRY M.CHILES ; �' PRUPOSED WELLA}RIVEWAY ;; NEW 50'& VARIABLE D.B.730-467 SITE WIDTH PRIVATE D.B.332-348 PLAT _ . Is ACCESS EASEMENT D.8.226-203 PLAT m IS ti i � IS„4 ,,,, �. . - �, L 9,,;;',;L16 P PARCEL 'L30 IS 50. 00 A m 100 IS AT 10.00' s POINT IN POND END PRIVATE J ACCESS ESMT f ,2 Q _;i/ PON. D L33' -;\ - _____.,. ' IS,/ �3A IRON �` � . <y� '�----.. /I `) IRON L35 ,' FOUND C 3e (-10 L3 r FOUND .. _ IRON f IRON IS C�1 L9 L8 ' ' -F.QUHn cnllun ,�:� FLAG FLAG Scale 1"= 300' Soil Profile Hole °2G� X20 022 lE e FLAG '10° 5 House, Well and Drain Field Sites #18G FLAG ' #23 N6. G'�� / 7#1-211 ”.'835 FLAG f, Parcel 3 i AG - z4 A Division of Tax Map 55-23 PROPOSED F Napo / SEPTIC A'bemarle County, Virginia - s La AA)) Steve Gooch Consulting Geologist j ' `'>'Q % 703 Oliver Creek Road �(0 ,/$ °�a,), Troy_ Virginia 22974 �Zti/ 'r