HomeMy WebLinkAboutARB202200043 Plan - Approved 2022-06-17SIGN INVENTORY
SUB402318 Subaru of Charlottesville
E01
2
Existing M30 Monument Rfc & Retrofit
N01
3
53"h 2019 Chrome Logo
NO2
3
36"h 2019 "SUBARU" Channel Letters
NO3
3
24"h "UMANSKY" Channel Letters
N04
3
18"h "SERVICE" Channel Letters
N05
3
12"h "EXPRESS" Channel Letters
N06
4
36"h 2019 Chrome Logo
N07
4
24"h 2019 "SUBARU" Channel Letters
P H I L A D E L P H I A S I G N
BRINGING THE WORLD'S BRANDS TO LIFE
TITLE
Subaru
DWG BY
7AS
DATE
03.08.22
DATE REVISION By
03.09.22 Added NO6. N07......................................................................................................................................................7AS
THIS S AN ORIGIN4L UNPUBUSHED
DRAWING CREATED BY RS.C.O. T
IS SUBHITIED FOR YOUR PERSONAL
USE INLONJUNCTIONtYTHAPROJECT
BEING PLANNED FOR YOU BY NS.C.O.
B S NOT TO BE SHOWN TO ANYONE
DE YUR ORGANIATION NOR
IS IT TO BE USED, CONED, REPRODUCED,
ORWIBTEDINANYFASHION.
ADDRESS SUB402318 Umansky Subaru of Charlottesville
960 Hilton Heights Road, Ste. B
Charlottesville, VA 22901
DWG NUM
B100209
SUBARU. Retailer Executive Manager Signature: Dale:
SHEET
1
707 WEST SPRING GARDEN ST • PALMYRA, NJ • OW65 • P: 8561 • F: 856-829-8549 - WEB: http://W Ww.philadelphimign.mm
lQuistopher Taggart, Digital Signature Per email from Beth Robinson at
N01 Existing M30 Double Faced Illuminated Monument w/ 2019 Reface & LED Retrofit This approval is only for the Architectural Review Board Hlghtech Signs dated 5/12/2022, the
It is only one approval required before installing a sign.
Zoning.. building, and other approvals may still be existing brick base is to remain.
pending for your sign permit
June 17. 2022
TT
E01 - EXISTING M30 DOUBLE FACED ILLUMINATED MONUMENT 2019 REFACE & LED RETROFIT
Scale: 3/4"=1'0"
P H I L A D E L P H I A S I G N
BRINGING THE WORLD'S BRANDS TO LIFE
TITLE
Subaru
DWG BY
7AS
DATE
03.08.22
DATE REVISION BY
03.09.22 Added NOS. N07......................................__......__............__...............................................................__...............ZAS
THIS 6 AN ORIGIN4L LWPUBUSHED
DRAWING CREATED BY RS.C.O. T
IS SUBMITTED FOR YOUR PERSONAL
USE INLON1UNCEONWITH APROJECT
BEING PLANNED FOR YOU BY NS.C.O.
IFISNOTTO BE SHOWN TO ANYONE
SUDE YOUR ORI NOR
IS IT TO BE USED, CONED, REPRODUCED,
ORWIRTMINANYFASHBIN.
ADDRESS SUB402318 Umansky Subaru of Charlottesville
960 Hilton Heights Road, Ste. B
Charlottesville, VA 22901
DWG NUM
B100209
11 SUBARU. Retailer Executive Manager Signature: Dale:
SHEET
2
707 WEST SPRING GARDEN ST • PALMYRA, NJ • OW65 • P: 856-a294460 • F: 856-829-8549 - WEB: http://www.philadelphimign.mm
N01 53" 2019 Illum Logo - 53" h x 9' 0'W (39.8 Sq Ft)
NO2 36' 2019 Illum Blue Channel Letters "SUBARU" - 23 1-3PV' OAL (69.4 Sq Ft)
NO3 24" Illum Blue Channel Letters "UMANSKY' -160" OAL (32 Sq Ft)
N04 18" Illum Blue Channel Letters "SERVICE" -10' ,V CAL (15.5 Sq Ft)
N05 12" Illum Blue Channel Letters "EXPRESS" - 68" OAL (6.7 Sq Ft)
West Elevation
ALL SIGNS RENDERED PROPORTIONALLY TO THE ELEVATIONS
.C` rTH ,Tr IQnistopher Taggart, Digital Signature
This approval is only for the ArchileChNal Review Board.
It is only one approval required before installing a sign.
- Zoning, building, and other approvals may still be
pending for your sign permit.
June 17, 2022
NOTE: Interior wireways Wor exterior parapet raceways
are an extra cost where applicable to conceal or other-
wise house letter to letter wiring & power supplies for
illuminated letters Wor logos.
P H I L A D E L P H I A S I G N
BRINGING THE WORLD'S BRANDS TO LIFE
TITLE
Subaru
DWG BY
ZAS
DATE
03.08.22
DATE REVISION BY
03.09.22 Atltletl NO6. N07 ZAS
THIS iS AN ORIGINAL LNPIIBUMED
MINING CREATED BY P.SC.O. T
FOR YOUR PERSONAL
ISEIN CONJUNCTION
BEINGP PLANNED
BEING PLANNED FOR YOU BY P.SC.O.
IT IS NOT TO BE SHOWN TO ANYONE
ORGANIZAION NOR
IS RSTO BEDE USE➢, COPIED,T REPRODUCED,
oR EXHIRDIED IN ANY FASHDN.
ADDRESS SU6402318 Umansky Subaru of Charlottesville
o
960 Hilton Heights Road, Ste. B
Charlottesville, VA 22901
DWG NUM
B100209
IM SUBARU. Retailer Executive Manager Signature: Date:
SHEET
3
707 WEST SPRING GARDEN ST • PALMYRA, NJ • OW65 • P: 856-a294460 • F: 856-829-8549 - WEB: http://w .philadelphimign.mm
N06 36" 2019 Illum Logo- 36"h x 6' 1-3/8"w (18.34 Sq Ft)
N07 24" 2019 Illum Blue Channel Letters "SUBARU" -16 5-1/8" CAL (30.85 Sq Ft)
South Elevation
ALL SIGNS RENDERED PROPORTIONALLY TO THE ELEVATIONS
IQuistopher Taggart, Digital Signature
This approval is only for the Architectural Review Board.
It is only one approval required before installing a sign.
Zoning, building, and other approvals may still be
pending for your sign permit.
June 17, 2022
NOTE: Interior wireways &/or exterior parapet raceways
are an extra cost where applicable to conceal or other-
wise house letter to letter wiring & power supplies for
illuminated letters &/or logos.
P H I L A D E L P H I A S I G N
BRINGING THE WORLD'S BRANDS TO LIFE
TITLE
Subaru
DWG BY
7AS
DATE
03.08.22
DATE REVISION BY
03.09.22 Atltletl N06. N07 ZAS
THIS IS AN ORIGINAL LNPIIBLIMED
DRAWING CREATED BY P.S.C.O. T
ISEIN OTEDFOR YN w!"'i PROD
PROJECT
UBNCOWNDFO YOU
BEING PLANNED FOR YON BY P.SC.O.
IT IS NOT TO BE SHOWN TO ANYONE
ORGANIZAION NOR
IS IT TO BESUDE USE➢, COPIED,T REPRODUCED,
OR EXURTIED IN ANY FASHDN.
ADDRESS SU6402318 Umansky Subaru of Charlottesville
960 Hilton Heights Road, Ste. B
Charlottesville, VA 22901
DWG NUM
B100209
� SUBARU. Retailer Executive Manager Signature: Date:
SHEET
4
707 WEST SPRING GARDEN ST • PALMYRA, NJ • OW65 • P: 856-8294460 • F: 856-829-8549 - WEB: http://www.philadelphimign.mm
F'1
23' 1-3/4"
N01-53"2019ILLUM LOGO
Scale: B/B"=1'0"
•[UMANS KY
ff
IOMstopher Taggal Digital Signature
The approval is only for the Amhiterb ral Review Board.
It is only one approval required before installing a sign.
Zoning, building, and other approvals may All be
pending for Your sign parent
ov4., June 17, 2022
NO3 - 24" ILLUM CHANNEL LETTER
Scale: 3/8" = 1'0"
NO2 - 36"2019 ILLUM CHANNEL LETTERS
Scale: No=1'0"
10' 4"
-SERVICE
XXPRESS
N05 -12" ILLUM CHANNEL LETTER
Scale: 3/4"=1'0"
6' 1-318° 15' 5-1/8°
N06-36"20191LLUM LOGO
Scale: 'k"=1'0"
PHILADELPHIASIGN
BRINGING THE WORLD'S BRANDS TO LIFE
N04-18"ILLUM CHANNEL LETTER
Scale: 1/2" =1'0"
N07 - 24"2019 ILLUM CHANNEL LETTERS
Scale: Y2"=1'0"
N
A
NOTE: Interior wireways &/or exterior parapet raceways
are an extra cost where applicable to conceal or other-
wise house letter to letter wiring & power supplies for
illuminated letters &/or logos.
TITLE Subaru DWG BY ZAS, DATE 03.08.22 DATE REVISION BY
03.09.22 Added N06, N07 ZAS
ADDRESS SUB402318 Umansky Subaru of Charlottesville DWG NUM
B100209
960 Hilton Heights Road, Ste. B
Charlottesville, VA 22901 SHEET 5 suBAFtt,J. Retailer Executive Manager Signature: Dale:
707 WEST SPRING GARDEN ST • PALMYRA, NJ • 08065 • P: 856-8294460 • F: 856-829-8549 - WEB: http://w .philadelphimign.mm
THIS IS AN ORIGINAL LNPUBUSHED
DRAWING CREATED BY RS.C.O. T
IS SUBMITHED FOR YOUR PERSONAL
USE IN CONJUNCTION WITH A PROJECT
BEING PLANNED FOR YOU BY N&C.O.
B IS MOTTO BE SHOWN TO ANYONE
OUTSIDE YOUR ORGANPABON NOR
IS ITTO BE USED, COWED, REPRODUCED,
OR E)O IRRED IN ANY FASHION.
.040" x 4.3 Coil Returns
Brushed Aluminum/
White Precoat
1" Wide Jewelite Metallic
Silver Trim Cap
1/8" x 3/4" Lexan Angle
Pop -Riveted To Return
1/8" Thk Clear Acrylite Resist -
65 w/ Arlon 2500-3101 Blue
Vinyl Over Avery6001 White
Vinyl Applied First Surface
.118" Routed Makrolon LD B48
White (2447) Diffuser Panel
Secured To Lexan Angle w/ (4)
#8 x 1/2" Pan Head Screws
AgiLight Pro 215
6500K White LED's
3mm Compbond ACM
Backs - White/Mill
3/8" 0 x 4" Lag Bolt Into -
3/4" Thk Exterior Grade
Plywood (Min 4 Per Logo)
#8 x 1/2" Pan Head
Screws
1/4" 0 Drain Hole
with Light Cover
Slate Over Galvanized Studs
& 3/4" Thk Exterior Grade
Plywood (By Others)
ELECTRICAL LOAD
2.0 Amps @ 120 Volts
ELECTRICAL REQ'MTS
(1) 20 Amp/120 Volt Circuit
STANDARD WALL SIGN NOTES:
1. Sufficient Primary Circuit In Vicinity Of Sign
By Others.
2. Final Primary Hook-up By Sign Installer,
Where Allowed By Local Codes.
3. Sign Shall Be U.L. Listed.
4. Mounting Hardware By Sign Installer.
4"
0
LOGO CROSS SECTION
SCALE: 1 1/2" = V-0"
1/2" 0 Chase Nipple
& Coupling
Primary Power To
J/B By Other
.040" x 4.3 Coil Returns —
Brushed Aluminum/
White Precoat
1" Wide Jewelite Metallic —
Silver Trim Cap
3/16" #2447 White Acrylic w/ -
3M 3635-8057 Perforated Day
Night Vinyl Laminated To Face
(Blue By Day, White By Night)
3mm beBond ACP
Backs - White/Mill
AgiLight Pro 215 —
6500K White LED's
1/4" 0 x 1 1/2" Sheet Metal
Screws Into Wall Panels
(Minimum 4 Per Letter)
#8 x 1/2" Pan Head
Screws
1/4" 0 Drain Holes w/
Light Shield Cover
(Min 1 Per Letter Stroke)
Silver Alucobond Aluminum
Wall Panels Over Existing
Dealership Fascia
LETTER CROSS SECTION
SCALE: 1 1/2" = V-0"
1/2" 0 Chase
Nipple & Coupling
Low Voltage
Secondary
Wiring: 3-Wire
(PLTC) 14 GA
Supply Wire
LED Power Supply
In Enclosure w/
Shut-off Switch
1/2" 0 Flexible
Conduit For
Primary Hook-up
Lockable Disconnect
Switch To Be Supplied
By Others w/ Primary
Power
ELECTRICAL LOAD
3.0 Amps @ 120 Volts
ELECTRICAL REQ'MTS
(1) 20Amp/120 Volt Circuit
STANDARD LETTER NOTES:
1. Sufficient Primary Circuit In Vicinity Of Sign
By Others.
2. Letter To Letter Wiring & Final Primary Hook-up
By Sign Installer, Where Allowed By Local Codes.
3. Sign Shall Be U.L. Listed.
4. Mounting Hardware By Sign Installer.
5. Full Size Drilling Template Furnished With Sign.
6. This Sign has been Designed with the Criteria
as set forth in the IBC 2003 & IBC 2006. The
Design Meets or Exceeds those Requirements
for the Geographical Location in Which it is to
be Erected.
P H I L A D E L P H I A S I G N
BRINGING THE WORLD'S BRANDS TO LIFE
TITLE
Subaru
DWG BY
ZAS
DATE
03.08.22
DATE REVISION BY
03.09.22 Added NO6. N07......................................__......__............__...............................................................__............_.ZAS
THIS IS AN ORIGINAL LNUMED
PUBDRAWING CREATED BY RSCA. T
IS SUBMITTED FOR YOUR PERSONAL
USE INLONIUNCTANW APROJECT
BEING PLANNED FOR YOU BY NS.C.O.
IT IS NOT TO BE SHOWN TO ANYONE
UR ORGANIATION NOR
IS IT TO BERGE USED, CONED, REPROWCEO,
ORMIREDINANYFASHION.
ADDRESS SU6402318 Umansky Subaru of Charlottesville
o
960 Hilton Heights Road, Ste. B
Charlottesville, VA 22901
DWG NUM
B100209
SUBARU. Retailer Executive Manager Signature: Date:
SHEET
6
707 WEST SPRING GARDEN ST • PALMYRA, NJ • OW65 • P: 856-a294460 • F: 856-829-8549 - WEB: http://w .philadelphimign.mm