HomeMy WebLinkAboutSUB201300030 Certified Engineer's Report 2022-10-28 (3)Concrete Placement Report
CroO&Robertson, Inc.
VX�K Crozetzet Office
6185 Rockfish Gap Turnpike
Crozet, VA 22932
Phone:434.823.5154 www.FandR.com
Client: Recipients:
Stanley Martin Homes Distribution List
11710 Plaza America Drive
Reston VA 20190
Westlake Hills Phase II, III, and IV
Westlake Hills
Crozet VA 22932
Location: Site - Curb & Gutter
Location Details:
Eastern Ave between Westhall Drive and Jonna Street
Inspection Type: Inspection
Frequency: Continuous
Weather: Clear
Air Temp:
Report #:
Work Order #:
Bldg Permit No.:
CCPL:7120-04605
7120-04605
The results provided herein relate only to the items inspected and/or tested.
This report shall not be reproduced, except in full, vnthout the prior written
approval of F&R.
Reviewed By: Taylor Lance J
Review Date: 09/16/2020
Activity Date: 08125/2020
Personnel: Ellis Daniel A
Title: Technician
Wind Speed:
82 °F Concrete Volume Placed:
WE Tests Performed:
Air entrainment, slump, and temperature. Cast one set of six each 4x8 test cylinders.
Notes:
F&R on site as requested for observation and testing of concrete during placeml
mph
8.0 yd'
Form No: 190028
C-Concrete Placement Report
Page 1 of 2
9
Freehling & Robertson, Inc.
Crozet Office
6185 Rockfish Gap Turnpike
Crozet, VA 22932
Phone: 434.823.5154 www.FandR.com
Stanley Martin Homes
11710 Plaza America Drive
Reston, VA 20190
71VO037
Westlake Hills Phase II, III, and IV
Westlake Hills
Crozet, VA 22932
Concrete/Masonry Field Report
CC: Lance Taylor Report No: FC:7120-04605
Issue No: 1 All.
Approved By: Taylor Lance J
General Fieid Data
Technician: Ellis Daniel A
Test Date: 8/2512020
Weather: Clear
Test Results
Sample/Set No. No. of Sample Type
Ticket Time Batch to
Cum. yd' Slump (in) Air Air Temp. Material
Spec.
Batched) Unload
Placed Content ff) Temp. ff)
Unloaded min
I %)
7120-04605-COl 6 CONCRETEA"
11109474 11:00\12:30 90
8.0 6.00 5.4 82 89
Location & Remarks
General Location: Road
Sample/Set No. Element Type(s)
Location
Remarks
7120-04605-COl Site - Curb & Gutter
Right side of roadway
Mix Data
Sample/Set No. Supplier
Mix
Design Required
Strength (psi) Strength (psi)
7120-04605-COl Allied Concrete Products, LLC
A3 CURB
3000 3000
Notes
1. Applicable ASTNI standards unless otherwise indirated:Sampling: C31 (except sec. 10.1.2); Values shown in red are out at speci ration
Slump: C143; Air Content: C231; Temperature: C1064; Sampling: C172; Unit Weight: C138,
The results provided herein relate only to the items inspected anNor tested. This report shall not be reproduced, except in full, without the prior written approval of F&R
Form No: 18971, Report No: FC:7120-04605 0 2000-2020 QESTLab by SpectraQEST.com Page 2 of 2
Field Report
Cro&Robertson, Inc.
VX�KCrozetzet Office Report #: GFLD:7120-04699
6185 Rockfish Gap Turnpike Work Order #: 7120-04699
Crozet, VA 22932
Phone: 434.823.5154 www.FandR.com Bldg Permit No.:
Client: Recipients: The results provided herein relate only to the items inspected and/or tested.
This report shall not be reproduced, except in full, vnthout the prior written
Stanley Martin Homes Lance Taylor
approval of F&R.
11710 Plaza America Drive
Reston VA 20190
1V0037
Westlake Hills Phase II, III, and IV
Reviewed By: Taylor Lance J
Westlake Hills
Crozet VA 22932 Review Date: 09/16/2020
General Information
Location: Activity Date: 08126/2020
Location Details:
Jobsite 7
Inspection Type: Observation Personnel: Lowry Burnett T
Frequency: Periodic Title: Technician
Weather: Clear Wind Speed: mph Air Temp: 880F
Category: C - Concrete Coverage: M - Sample Pick -Up
Field Notes
F&R representative on site as requested for cylinder retrieval and transport to Crozet lab.
r
Form No: 190005 G-Field Report Page 1 of 1
Concrete Placement Report
FroO&Robertson, Inc. � Crozetzet Office
6185 Rockfish Gap Turnpike
® Crozet, VA 22932
Phone:434.823.5154 www.FandR.com
Client:
Stanley Martin Homes
11710 Plaza America Drive
Reston VA 20190
Project:
Westlake Hills Phase II, III, and IV
Westlake Hills
Crozet VA 22932
Location: Site - Curb & Gutter
Curb and gutter at the intersection of
Location Details: Eastern and Jonna.
Activity Date: 11/04/2021
Activity Type: Observation
Frequency: Continuous
Report #: CCPL:7121-09137-1 Issue #: 1
Work Order #: 7121-09137
Client Report No.:
The results provided herein relate only to the items inspected and/or tested.
Taylor This report shall not be reproduced, except in full, without the prior written
approval of F&R.
Reviewed By: Taylor Lance J
Review Date: 12/09/2021
Personnel: Thompson Earl F
Title: Technician
Weather: Partly Cloudy
Wind Speed: mph Air Temp:
New Discrepancies Recorded?"
Ej Yes, see "Discrepancies Noted" R] No
Concrete Volume Placed: 10.00 yda
Tests Performed:
Air entrainment, slump, and temperature. Cast one set of five each 4x8 test cylinders.
320F
Form No: 190028 C-Concrete Placement Report Page 1 of 3
Concrete Placement Report
0FroOffi&Robertson, Inc.
CrozetzetOffice
6185 Rockfish Gap Turnpike
Crozet, VA 22932
Phone:434.823.5154 www.FandR.com
9
n
Activity Date: 11/04/2021
Report No.: CCPL:7121-09137-1
Client Name: Stanley Martin Homes
Project Name: Westlake Hills Phase II, III, and IV
Project No.: 71 V0037
Work Order No.: 7121-09137
Image Details
Description: curb and gutter section
Date Taken:
Taken By: et
I
Form No: 190028 C-Concrete Placement Report Page 2 of 3
ro&Robertson, Inc.
Crozet
"Y(K rozet zetOThce
v 6185 Rockfish Gap Turnpike
Crozet, VA 22932
Phone: 434.823.5154 www.FandR.com
0
Concrete/Masonry Field Report
Client: Stanley Martin Homes
CC: Lance Taylor
Report No: FC:7121-09137
11710 Plaza America Drive
Issue No: 1
Reston, VA 20190
Project: 71 V0037
Westlake Hills Phase II, III, and IV
Westlake Hills
Reviewed By: Taylor Lance J
Crozet, VA 22932
Review Date: 12/9/2021
neral Field Data
or
Technician: Thompson Earl F
Test Date: 11/4/2021
Weather: Partly Cloudy
Test Results
Sample/Set No. No. of Sample Type
Ticket Time
Batch to Cum. yd3 Slump (in) Air Air Temp. Material
Spec.
Batched)
Unload Placed Content ff) Temp. ff)
Unloaded
(min) I%)
7121-09137-001 5 CONCRETEA"
10937200 06:52\08:44
112 10.0 2.75 5.1 32 64
Location & Remarks
General Location: Curb and gutter at the intersection of Eastern and Jonna
Sample/Set No. Element Type(s)
Location
Remarks
7121-09137-001
Jonna end
Mix Data
Sample/Set No. Supplier
Mix
Design Required
Strength (psi) Strength (psi)
7121-09137-001 Allied Concrete Products, LLC
BC CURB
3000 3000
Notes emarks
1. Applicable TM standards unless otherwise indicated:Sampling: C31 (except sec. 10.1.2);
Slump: C143; Air Content: C231; Temperature: C1084; Sampling: C172; Unit Weight: C138;
The results provided herein relabe only to the items inspected anNor tested. This report shall not be reproduced, except in full, without the prior written approval of FBR.
Form No: 18971, Report No: FC:7121-09137 02000-2021 QESnab by SpectraQEST.cnm Page 3 of 3
ro&Robertson, Inc.
Crozet
"Y(K rozet zetOTfice
v Crozet, VA
22932 Turnpike Concrete/Masonry Strength Report
Crozet, VA 22932
Phone: 434.823.5154 mnNw.FandR.com
0
Client: Stanley Martin Homes CC: Lance Taylor Report No: CTR:7121-09137-001
11710 Plaza America Drive Issue No: 1
Reston, VA 20190
Project: 71 V0037
Westlake Hills Phase II, III, and IV
Westlake Hills EReD
: Taylor Lance J
Crozet, VA 22932 12/9/2021
Mix Data
Supplier: Allied Concrete Products, LLC
Plant: 9
Mix: BC CURB
Specified Design Strength (psi): 3000 at age 28 days
Sample Detail
Date Sampled: 11/04/21 Date Received: Specification: Design
General Location: Curb and gutter at the intersection of Eastern and Jenne Measured Specified
Element Type(s): Slump (in): ASTM C 143 2,75
Sample Location: Jenne end Slump w/ Plasticizer (in):
Curing Method: Field Sample No.: Air Temp ff): 32
Field Cure Temp (°F) High: Concrete Temp ff): ASTM C 1064 64
Low: Air Content(%) ASTM C231 5.1
Contractor: Unit Weight(pcf): ASTM C 138 N/A
Ticket no.: 10937200 Truck No.: 368 Volume of Density Measure (it): N/A
Sampled By: Thompson Ead F Batch Size (yd'): 10.0 Time Batched: 06:52
Submitted By: Yd' Placed: 10.0 Time Sampled: 07:45
Weather: Partly Cloudy Water Added (gal) Before: Time Placed: 08:44
After: Time in Truck (mins): 112
Compressive Strength of Concrete Cylinders ASTM C 39
Specimen ID Date Tested Age Diameter Length Area Type of Maximum Load Fracture Compressive
(Days) (in) (in) (In') Cap 0110 Type l Remarks Strength (psi)
7121-09137-001\1 11/11/21 7 4.00 8.00 12.57 U 58500 2 4660
7121-09137-001\2 12/02/21 28 U
7121-09137-00143 12/02/21 28 U
7121-09137-00l W 12/02/21 28 U
Average 28 Day Compressive Strength (psi)
Required Strength (psi) 3000
7121-09137-001\5 12/30/21 56 U
Notes Remarks
1. Sampling to TM 172 Fracture Type: 2 = Well -formed cone one ead, vertical cracks in caps, no cone on opp. end
2. Speaments) prepared to ASTM C 31
3. Capping: B = Bonded ASTM C 617,U = Unbonded ASTM C 1231
The results provided herein relffie only to the items inspected andlor tested. This report shall not i e reproduced, except in full, without the prior written approval of FBR.
Form No: 18947, Report No: CTR:7121-09137L01 0 2000-2021 QESTI-ab by SpectmQEST.com Page 1 of 1